From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/audiocodes/AC-PMPSTN-MIB | 824 ++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 824 insertions(+) create mode 100644 MIBS/audiocodes/AC-PMPSTN-MIB (limited to 'MIBS/audiocodes/AC-PMPSTN-MIB') diff --git a/MIBS/audiocodes/AC-PMPSTN-MIB b/MIBS/audiocodes/AC-PMPSTN-MIB new file mode 100644 index 0000000..0c0adac --- /dev/null +++ b/MIBS/audiocodes/AC-PMPSTN-MIB @@ -0,0 +1,824 @@ + +AC-PM-PSTN-MIB DEFINITIONS ::= BEGIN + + + IMPORTS + + + OBJECT-TYPE, + MODULE-IDENTITY FROM SNMPv2-SMI + TAddress, + DisplayString, + DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC + IpAddress FROM RFC1155-SMI + Unsigned32, + Integer32, + enterprises FROM SNMPv2-SMI + SnmpAdminString FROM SNMP-FRAMEWORK-MIB + audioCodes, + acRegistrations, + acGeneric, + acProducts,acBoardMibs,acPerformance FROM AUDIOCODES-TYPES-MIB; + + +acPMPSTN MODULE-IDENTITY + LAST-UPDATED "200902050516Z" --Thursday, February 05, 2009 + ORGANIZATION "AudioCodes Ltd" + CONTACT-INFO + "Postal: Support + AudioCodes LTD + 1 Hayarden Street + Airport City + Lod, ISRAEL 70151 + Tel: 972-3-9764000 + Fax: 972-3-9764040 + Email: support@audiocodes.com + Web: www.audiocodes.com" + + + DESCRIPTION + "The AC-PM-PSTN MIB offers performance monitoring +For the PSTN related elements in Audiocodes' devices. +The Configuration sub-tree is for configuring the interval +Period length for the entire AC-PM-PSTN MIB, and the +different tables' thresholds. +The Data sub-tree presents the tables of monitored +elements. + +Note - for the entire MIB the value (-1) means the value +Asked for is either not supported or currently not relevant +(this is for when values asked for are for intervals not yet +recorded." + + + + ::= {acPerformance 10} + + + + + + + + + acPMPSTNConfiguration OBJECT IDENTIFIER ::= {acPMPSTN 1} + + + acPMPSTNConfigurationPeriodLength OBJECT-TYPE + SYNTAX Unsigned32 (0..894780) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Length of monitoring intervals for entire MIB. Time is in minutes. +Access: Instant." + ::= {acPMPSTNConfiguration 1} + + + + acPMPSTNConfigurationResetTotalCounters OBJECT-TYPE + SYNTAX INTEGER { + resetCountersDone(1) +, + resetTotalCounters(2) + + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Total-Counters Reset. To reset the total counters, set the +value of this object to resetTotalCounters(2). +Access: Instant." + ::= {acPMPSTNConfiguration 2} + + + + acPMTrunkUtilizationAttributes OBJECT IDENTIFIER ::= {acPMPSTNConfiguration 31} + + + acPMTrunkUtilizationAttributesHighThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..32) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High threshold. +Access: Instant." + ::= {acPMTrunkUtilizationAttributes 1} + + + + acPMTrunkUtilizationAttributesLowThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..32) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low threshold. +Access: Instant." + ::= {acPMTrunkUtilizationAttributes 2} + + + + acPMPSTNChannelsAttributes OBJECT IDENTIFIER ::= {acPMPSTNConfiguration 32} + + + acPMPSTNChannelsAttributesInServiceHighThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..32) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High threshold. +Access: Instant." + ::= {acPMPSTNChannelsAttributes 1} + + + + acPMPSTNChannelsAttributesInServiceLowThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..32) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low threshold. +Access: Instant." + ::= {acPMPSTNChannelsAttributes 2} + + + + acPMPSTNChannelsAttributesOutOfServiceHighThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..32) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High threshold. +Access: Instant." + ::= {acPMPSTNChannelsAttributes 3} + + + + acPMPSTNChannelsAttributesOutOfServiceLowThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..32) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low threshold. +Access: Instant." + ::= {acPMPSTNChannelsAttributes 4} + + + + acPMPSTNChannelsAttributesInMaintenanceHighThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..32) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High threshold. +Access: Instant." + ::= {acPMPSTNChannelsAttributes 5} + + + + acPMPSTNChannelsAttributesInMaintenanceLowThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..32) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low threshold. +Access: Instant." + ::= {acPMPSTNChannelsAttributes 6} + + + + acPMPSTNData OBJECT IDENTIFIER ::= {acPMPSTN 2} + + + acPMPSTNDataAcPMPSTNTimeFromStartOfInterval OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time in seconds since the start of the current interval. +MIB specific." + ::= {acPMPSTNData 1} + + + + -- **************************************** + -- acPMTrunkUtilization table declaration + -- **************************************** + acPMTrunkUtilizationTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcPMTrunkUtilizationEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Number of active channels per trunk (index: trunk number)." + ::= {acPMPSTNData 21} + + + + -- **************************************** + -- acPMTrunkUtilization table entry + -- **************************************** + acPMTrunkUtilizationEntry OBJECT-TYPE + SYNTAX AcPMTrunkUtilizationEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acPMTrunkUtilizationTrunkNum,acPMTrunkUtilizationInterval} + ::= {acPMTrunkUtilizationTable 1} + + + + -- **************************************** + -- acPMTrunkUtilization TABLE + -- **************************************** + AcPMTrunkUtilizationEntry ::= SEQUENCE { + acPMTrunkUtilizationTrunkNum Unsigned32, + acPMTrunkUtilizationInterval Unsigned32, + acPMTrunkUtilizationVal Gauge32, + acPMTrunkUtilizationAverage Integer32, + acPMTrunkUtilizationMax Integer32, + acPMTrunkUtilizationMin Integer32, + acPMTrunkUtilizationVolume Counter32, + acPMTrunkUtilizationTimeBelowLowThreshold Integer32, + acPMTrunkUtilizationTimeBetweenThresholds Integer32, + acPMTrunkUtilizationTimeAboveHighThreshold Integer32, + acPMTrunkUtilizationFullDayAverage Integer32, + acPMTrunkUtilizationTotal Integer32 + } + + + + acPMTrunkUtilizationTrunkNum OBJECT-TYPE + SYNTAX Unsigned32 (0..83) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Trunk number. +0 is the first trunk." + ::= {acPMTrunkUtilizationEntry 1} + + + + acPMTrunkUtilizationInterval OBJECT-TYPE + SYNTAX Unsigned32 (0..2) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Interval index. +0 - current period (incomplete monitoring - mid period). +1 - Last full period. +2 - One before last." + ::= {acPMTrunkUtilizationEntry 2} + + + + acPMTrunkUtilizationVal OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of gauge or counter." + ::= {acPMTrunkUtilizationEntry 3} + + + + acPMTrunkUtilizationAverage OBJECT-TYPE + SYNTAX Integer32 (-1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value within the period time." + ::= {acPMTrunkUtilizationEntry 4} + + + + acPMTrunkUtilizationMax OBJECT-TYPE + SYNTAX Integer32 (-1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum value within the period time." + ::= {acPMTrunkUtilizationEntry 5} + + + + acPMTrunkUtilizationMin OBJECT-TYPE + SYNTAX Integer32 (-1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum value within the period time." + ::= {acPMTrunkUtilizationEntry 6} + + + + acPMTrunkUtilizationVolume OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Activity volume." + ::= {acPMTrunkUtilizationEntry 7} + + + + acPMTrunkUtilizationTimeBelowLowThreshold OBJECT-TYPE + SYNTAX Integer32 (-1..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Percent of interval time for which gauge is below what was determined +as the low threshold." + ::= {acPMTrunkUtilizationEntry 8} + + + + acPMTrunkUtilizationTimeBetweenThresholds OBJECT-TYPE + SYNTAX Integer32 (-1..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Percent of interval time for which gauge is above what was determined +as the high threshold." + ::= {acPMTrunkUtilizationEntry 9} + + + + acPMTrunkUtilizationTimeAboveHighThreshold OBJECT-TYPE + SYNTAX Integer32 (-1..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Percent of interval time for which gauge is between what were +determined as the low and high thresholds." + ::= {acPMTrunkUtilizationEntry 10} + + + + acPMTrunkUtilizationFullDayAverage OBJECT-TYPE + SYNTAX Integer32 (-1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average of full 24 hours." + ::= {acPMTrunkUtilizationEntry 11} + + + + acPMTrunkUtilizationTotal OBJECT-TYPE + SYNTAX Integer32 (-1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total since last reset." + ::= {acPMTrunkUtilizationEntry 12} + + + + -- **************************************** + -- acPMPSTNTrunkActivitySeconds table declaration + -- **************************************** + acPMPSTNTrunkActivitySecondsTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcPMPSTNTrunkActivitySecondsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Counts activity seconds on the trunk." + ::= {acPMPSTNData 22} + + + + -- **************************************** + -- acPMPSTNTrunkActivitySeconds table entry + -- **************************************** + acPMPSTNTrunkActivitySecondsEntry OBJECT-TYPE + SYNTAX AcPMPSTNTrunkActivitySecondsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acPMPSTNTrunkActivitySecondsTrunkNum,acPMPSTNTrunkActivitySecondsInterval} + ::= {acPMPSTNTrunkActivitySecondsTable 1} + + + + -- **************************************** + -- acPMPSTNTrunkActivitySeconds TABLE + -- **************************************** + AcPMPSTNTrunkActivitySecondsEntry ::= SEQUENCE { + acPMPSTNTrunkActivitySecondsTrunkNum Unsigned32, + acPMPSTNTrunkActivitySecondsInterval Unsigned32, + acPMPSTNTrunkActivitySecondsVal Gauge32, + acPMPSTNTrunkActivitySecondsTotal Integer32, + acPMPSTNTrunkActivitySecondsVolume Counter32 + } + + + + acPMPSTNTrunkActivitySecondsTrunkNum OBJECT-TYPE + SYNTAX Unsigned32 (0..83) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Trunk number. +0 is the first trunk." + ::= {acPMPSTNTrunkActivitySecondsEntry 1} + + + + acPMPSTNTrunkActivitySecondsInterval OBJECT-TYPE + SYNTAX Unsigned32 (0..2) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Interval index. +0 - current period (incomplete monitoring - mid period). +1 - Last full period. +2 - One before last." + ::= {acPMPSTNTrunkActivitySecondsEntry 2} + + + + acPMPSTNTrunkActivitySecondsVal OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of gauge or counter." + ::= {acPMPSTNTrunkActivitySecondsEntry 3} + + + + acPMPSTNTrunkActivitySecondsTotal OBJECT-TYPE + SYNTAX Integer32 (-1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total since last reset." + ::= {acPMPSTNTrunkActivitySecondsEntry 4} + + + + acPMPSTNTrunkActivitySecondsVolume OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Activity volume." + ::= {acPMPSTNTrunkActivitySecondsEntry 5} + + + + acPMPSTNChannels OBJECT IDENTIFIER ::= {acPMPSTNData 31} + + + -- **************************************** + -- acPMPSTNNumOfChannelsInService table declaration + -- **************************************** + acPMPSTNNumOfChannelsInServiceTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcPMPSTNNumOfChannelsInServiceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Channels in service, per trunk." + ::= {acPMPSTNChannels 1} + + + + -- **************************************** + -- acPMPSTNNumOfChannelsInService table entry + -- **************************************** + acPMPSTNNumOfChannelsInServiceEntry OBJECT-TYPE + SYNTAX AcPMPSTNNumOfChannelsInServiceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acPMPSTNNumOfChannelsInServiceTrunkNum,acPMPSTNNumOfChannelsInServiceInterval} + ::= {acPMPSTNNumOfChannelsInServiceTable 1} + + + + -- **************************************** + -- acPMPSTNNumOfChannelsInService TABLE + -- **************************************** + AcPMPSTNNumOfChannelsInServiceEntry ::= SEQUENCE { + acPMPSTNNumOfChannelsInServiceTrunkNum Unsigned32, + acPMPSTNNumOfChannelsInServiceInterval Unsigned32, + acPMPSTNNumOfChannelsInServiceVal Gauge32, + acPMPSTNNumOfChannelsInServiceAverage Integer32, + acPMPSTNNumOfChannelsInServiceMax Integer32, + acPMPSTNNumOfChannelsInServiceMin Integer32, + acPMPSTNNumOfChannelsInServiceVolume Counter32 + } + + + + acPMPSTNNumOfChannelsInServiceTrunkNum OBJECT-TYPE + SYNTAX Unsigned32 (0..83) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Trunk number. +0 is the first trunk." + ::= {acPMPSTNNumOfChannelsInServiceEntry 1} + + + + acPMPSTNNumOfChannelsInServiceInterval OBJECT-TYPE + SYNTAX Unsigned32 (0..2) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Interval index. +0 - current period (incomplete monitoring - mid period). +1 - Last full period. +2 - One before last." + ::= {acPMPSTNNumOfChannelsInServiceEntry 2} + + + + acPMPSTNNumOfChannelsInServiceVal OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of gauge or counter." + ::= {acPMPSTNNumOfChannelsInServiceEntry 3} + + + + acPMPSTNNumOfChannelsInServiceAverage OBJECT-TYPE + SYNTAX Integer32 (-1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value within the period time." + ::= {acPMPSTNNumOfChannelsInServiceEntry 4} + + + + acPMPSTNNumOfChannelsInServiceMax OBJECT-TYPE + SYNTAX Integer32 (-1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum value within the period time." + ::= {acPMPSTNNumOfChannelsInServiceEntry 5} + + + + acPMPSTNNumOfChannelsInServiceMin OBJECT-TYPE + SYNTAX Integer32 (-1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum value within the period time." + ::= {acPMPSTNNumOfChannelsInServiceEntry 6} + + + + acPMPSTNNumOfChannelsInServiceVolume OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Activity volume." + ::= {acPMPSTNNumOfChannelsInServiceEntry 7} + + + + -- **************************************** + -- acPMPSTNNumOfChannelsOutOfService table declaration + -- **************************************** + acPMPSTNNumOfChannelsOutOfServiceTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcPMPSTNNumOfChannelsOutOfServiceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Channels out of service, per trunk." + ::= {acPMPSTNChannels 2} + + + + -- **************************************** + -- acPMPSTNNumOfChannelsOutOfService table entry + -- **************************************** + acPMPSTNNumOfChannelsOutOfServiceEntry OBJECT-TYPE + SYNTAX AcPMPSTNNumOfChannelsOutOfServiceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acPMPSTNNumOfChannelsOutOfServiceTrunkNum,acPMPSTNNumOfChannelsOutOfServiceInterval} + ::= {acPMPSTNNumOfChannelsOutOfServiceTable 1} + + + + -- **************************************** + -- acPMPSTNNumOfChannelsOutOfService TABLE + -- **************************************** + AcPMPSTNNumOfChannelsOutOfServiceEntry ::= SEQUENCE { + acPMPSTNNumOfChannelsOutOfServiceTrunkNum Unsigned32, + acPMPSTNNumOfChannelsOutOfServiceInterval Unsigned32, + acPMPSTNNumOfChannelsOutOfServiceVal Gauge32, + acPMPSTNNumOfChannelsOutOfServiceAverage Integer32, + acPMPSTNNumOfChannelsOutOfServiceMax Integer32, + acPMPSTNNumOfChannelsOutOfServiceMin Integer32, + acPMPSTNNumOfChannelsOutOfServiceVolume Counter32 + } + + + + acPMPSTNNumOfChannelsOutOfServiceTrunkNum OBJECT-TYPE + SYNTAX Unsigned32 (0..83) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Trunk number. +0 is the first trunk." + ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 1} + + + + acPMPSTNNumOfChannelsOutOfServiceInterval OBJECT-TYPE + SYNTAX Unsigned32 (0..2) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Interval index. +0 - current period (incomplete monitoring - mid period). +1 - Last full period. +2 - One before last." + ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 2} + + + + acPMPSTNNumOfChannelsOutOfServiceVal OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of gauge or counter." + ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 3} + + + + acPMPSTNNumOfChannelsOutOfServiceAverage OBJECT-TYPE + SYNTAX Integer32 (-1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value within the period time." + ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 4} + + + + acPMPSTNNumOfChannelsOutOfServiceMax OBJECT-TYPE + SYNTAX Integer32 (-1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum value within the period time." + ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 5} + + + + acPMPSTNNumOfChannelsOutOfServiceMin OBJECT-TYPE + SYNTAX Integer32 (-1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum value within the period time." + ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 6} + + + + acPMPSTNNumOfChannelsOutOfServiceVolume OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Activity volume." + ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 7} + + + + -- **************************************** + -- acPMPSTNNumOfChannelsInMaintenance table declaration + -- **************************************** + acPMPSTNNumOfChannelsInMaintenanceTable OBJECT-TYPE + SYNTAX SEQUENCE OF AcPMPSTNNumOfChannelsInMaintenanceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Channels in maintenance status (not in-service), per trunk." + ::= {acPMPSTNChannels 3} + + + + -- **************************************** + -- acPMPSTNNumOfChannelsInMaintenance table entry + -- **************************************** + acPMPSTNNumOfChannelsInMaintenanceEntry OBJECT-TYPE + SYNTAX AcPMPSTNNumOfChannelsInMaintenanceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX {acPMPSTNNumOfChannelsInMaintenanceTrunkNum,acPMPSTNNumOfChannelsInMaintenanceInterval} + ::= {acPMPSTNNumOfChannelsInMaintenanceTable 1} + + + + -- **************************************** + -- acPMPSTNNumOfChannelsInMaintenance TABLE + -- **************************************** + AcPMPSTNNumOfChannelsInMaintenanceEntry ::= SEQUENCE { + acPMPSTNNumOfChannelsInMaintenanceTrunkNum Unsigned32, + acPMPSTNNumOfChannelsInMaintenanceInterval Unsigned32, + acPMPSTNNumOfChannelsInMaintenanceVal Gauge32, + acPMPSTNNumOfChannelsInMaintenanceAverage Integer32, + acPMPSTNNumOfChannelsInMaintenanceMax Integer32, + acPMPSTNNumOfChannelsInMaintenanceMin Integer32, + acPMPSTNNumOfChannelsInMaintenanceVolume Counter32 + } + + + + acPMPSTNNumOfChannelsInMaintenanceTrunkNum OBJECT-TYPE + SYNTAX Unsigned32 (0..83) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Trunk number. +0 is the first trunk." + ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 1} + + + + acPMPSTNNumOfChannelsInMaintenanceInterval OBJECT-TYPE + SYNTAX Unsigned32 (0..2) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Interval index. +0 - current period (incomplete monitoring - mid period). +1 - Last full period. +2 - One before last." + ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 2} + + + + acPMPSTNNumOfChannelsInMaintenanceVal OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of gauge or counter." + ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 3} + + + + acPMPSTNNumOfChannelsInMaintenanceAverage OBJECT-TYPE + SYNTAX Integer32 (-1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average value within the period time." + ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 4} + + + + acPMPSTNNumOfChannelsInMaintenanceMax OBJECT-TYPE + SYNTAX Integer32 (-1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum value within the period time." + ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 5} + + + + acPMPSTNNumOfChannelsInMaintenanceMin OBJECT-TYPE + SYNTAX Integer32 (-1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum value within the period time." + ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 6} + + + + acPMPSTNNumOfChannelsInMaintenanceVolume OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Activity volume." + ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 7} + + + + + +END -- cgit v1.2.3