From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/cambium/CAMBIUM-PTP650-MIB | 6086 +++++++++++++++++++++++++++++++++++++++ 1 file changed, 6086 insertions(+) create mode 100644 MIBS/cambium/CAMBIUM-PTP650-MIB (limited to 'MIBS/cambium/CAMBIUM-PTP650-MIB') diff --git a/MIBS/cambium/CAMBIUM-PTP650-MIB b/MIBS/cambium/CAMBIUM-PTP650-MIB new file mode 100644 index 0000000..3836e0e --- /dev/null +++ b/MIBS/cambium/CAMBIUM-PTP650-MIB @@ -0,0 +1,6086 @@ + CAMBIUM-PTP650-MIB DEFINITIONS ::= BEGIN + + IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, + Integer32, IpAddress, + enterprises + FROM SNMPv2-SMI + MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP + FROM SNMPv2-CONF + DisplayString + FROM SNMPv2-TC + InetAddress, InetAddressType + FROM INET-ADDRESS-MIB; + + cambium MODULE-IDENTITY + LAST-UPDATED "201502060443Z" + ORGANIZATION "Cambium Networks Ltd." + CONTACT-INFO + "Post: Simon Whitaker + Cambium Networks Ltd. + Unit B2, + Linhay Business Park, + Eastern Road, + Ashburton, + Devon. + TQ13 7UP + United Kingdom + Phone: +44 (0) 1364 655 500 + Email: simon.whitaker@cambiumnetworks.com" + DESCRIPTION + "MIB for non-line-of-sight (NLOS) wireless ethernet bridge." + REVISION "201502060443Z" + DESCRIPTION + "PTP650-01-40: + Added Second Data Service attributes to support a second data path over + wireless link. + Added support for Cable Diagnostics. + Added IEEE 1588 Transparent Clock source port and Transparent Clock source + alarm attributes." + REVISION "201406181412Z" + DESCRIPTION + "PTP650-01-20: + Added TDM group and NIDU attributes to support the telecomms interfaces. + Added Router Protocols group to support Microwave Adaptive Bandwidth (MAB). + Added support for Out-Of-Band Remote Management, and for mute and enable + transmission. Renamed 'ethernet bridging' attributes to 'data bridging'. + Made more SyncE attributes writable." + REVISION "201402211503Z" + DESCRIPTION + "PTP650-01-10: + Added Synchronous Ethernet (SyncE) and IEEE 1588 Transparent Clock. + Support PTP650s. Clarified localPacketFiltering, regulatoryBand, + TDD Sync status & alarm. TX power max increased to 30dBm. + Modified the bit assignments of enabledDiagnosticAlarms to combine + the various status & warning bits for the main PSU, Aux & SFP ports + into a single portState bit." + REVISION "201308021028Z" + DESCRIPTION "PTP650-01-00: Initial revision." + ::= { enterprises 17713 } + + -- Groups in cambium + ptp OBJECT IDENTIFIER ::= { cambium 1 } + ptmp OBJECT IDENTIFIER ::= { cambium 2 } + ptp650 OBJECT IDENTIFIER ::= { cambium 7 } + + -- Groups in ptp650 + dfs OBJECT IDENTIFIER ::= { ptp650 3 } + bridge OBJECT IDENTIFIER ::= { ptp650 4 } + configuration OBJECT IDENTIFIER ::= { ptp650 5 } + ethernet OBJECT IDENTIFIER ::= { ptp650 6 } + tDM OBJECT IDENTIFIER ::= { ptp650 7 } + license OBJECT IDENTIFIER ::= { ptp650 8 } + management OBJECT IDENTIFIER ::= { ptp650 9 } + phyControl OBJECT IDENTIFIER ::= { ptp650 10 } + phyStatus OBJECT IDENTIFIER ::= { ptp650 12 } + alarms OBJECT IDENTIFIER ::= { ptp650 13 } + smtp OBJECT IDENTIFIER ::= { ptp650 15 } + snmpControl OBJECT IDENTIFIER ::= { ptp650 16 } + sntp OBJECT IDENTIFIER ::= { ptp650 17 } + reset OBJECT IDENTIFIER ::= { ptp650 18 } + versions OBJECT IDENTIFIER ::= { ptp650 19 } + pubStats OBJECT IDENTIFIER ::= { ptp650 20 } + encryption OBJECT IDENTIFIER ::= { ptp650 22 } + tDDControl OBJECT IDENTIFIER ::= { ptp650 23 } + aAAControl OBJECT IDENTIFIER ::= { ptp650 25 } + syslogControl OBJECT IDENTIFIER ::= { ptp650 24 } + routerProtocols OBJECT IDENTIFIER ::= { ptp650 26 } + cableDiagnostics OBJECT IDENTIFIER ::= { ptp650 27 } + supplementary OBJECT IDENTIFIER ::= { ptp650 96 } + ptpGroups OBJECT IDENTIFIER ::= { ptp650 98 } + ptpTraps OBJECT IDENTIFIER ::= { ptp650 99 } + ptpTrapPrefix OBJECT IDENTIFIER ::= { ptpTraps 0 } + + -- Compliance information + -- + ptpCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for the Cambium PTP MIB" + MODULE -- this module + MANDATORY-GROUPS { dfsGroup + , bridgeGroup + , configurationGroup + , ethernetGroup + , tDMGroup + , licenseGroup + , managementGroup + , phyControlGroup + , phyStatusGroup + , alarmsGroup + , smtpGroup + , snmpControlGroup + , sntpGroup + , resetGroup + , versionsGroup + , pubStatsGroup + , encryptionGroup + , tDDControlGroup + , aAAControlGroup + , syslogControlGroup + , routerProtocolsGroup + , cableDiagnosticsGroup + , supplementaryGroup + , notificationsGroup + } + ::= { ptp650 97 } + + dfsGroup OBJECT-GROUP + OBJECTS { dfsTableNumber + , extendedSpectrumScanning + , dfsMeans + , dfsNineNinePointNinePercentiles + , dfsPeaks + } + STATUS current + DESCRIPTION "The dfs object group." + ::= { ptpGroups 3 } + + bridgeGroup OBJECT-GROUP + OBJECTS { localPacketFiltering + } + STATUS current + DESCRIPTION "The bridge object group." + ::= { ptpGroups 4 } + + configurationGroup OBJECT-GROUP + OBJECTS { iPv4Address + , subnetMask + , gatewayIPAddress + , targetMACAddress + , masterSlaveMode + , maximumTransmitPower + , antennaGain + , cableLoss + , eIRP + , channelBandwidth + , linkName + , siteName + , accessMethod + , groupID + , iPv6Address + , iPVersion + , iPv6AutoConfiguredLinkLocalAddress + , iPv6PrefixLength + , iPv6GatewayAddress + , remoteInternetAddressType + , remoteInternetAddress + , subbandLowestFrequency + , subbandHighestFrequency + , enableTransmission + } + STATUS current + DESCRIPTION "The configuration object group." + ::= { ptpGroups 5 } + + ethernetGroup OBJECT-GROUP + OBJECTS { mainPSUPortAutoNegotiation + , mainPSUPortAutoNegAdvertisement + , mainPSUPortAutoMdix + , mainPSUPortStatus + , mainPSUPortSpeedAndDuplex + , dataPortWirelessDownAlert + , useVLANForManagementInterfaces + , vLANManagementPriority + , vLANManagementVID + , auxPortStatus + , auxPortSpeedAndDuplex + , ethernetPriorityTableNumber + , l2CPPriorityTableNumber + , iPDSCPPriorityTableNumber + , mPLSTCPriorityTableNumber + , managementPortWirelessDownAlert + , qOSPriorityScheme + , unknownNetworkPriorityQueueMapping + , dSCPManagementPriority + , dataBridgingStatus + , mainPSUPortAllocation + , auxPortAllocation + , sFPPortAllocation + , dataPortPauseFrames + , sFPPortAutoNegotiation + , sFPPortAutoNegAdvertisement + , sFPPortAutoMdix + , sFPPortStatus + , sFPPortSpeedAndDuplex + , auxPortPowerOverEthernetOutput + , auxPortPowerOverEthernetOutputStatus + , syncETracking + , syncEEquipmentClock + , mainPSUPortQLRxOverwrite + , mainPSUPortSSMTx + , sFPPortSSMTx + , auxPortSSMTx + , syncETrackingState + , mainPSUPortQLRx + , auxPortQLRx + , sFPPortQLRx + , mainPSUPortQLTx + , auxPortQLTx + , sFPPortQLTx + , mainPSUPortSyncEMasterSlaveStatus + , auxPortSyncEMasterSlaveStatus + , sFPPortSyncEMasterSlaveStatus + , mainPSUPortGigabitMasterSlaveStatus + , auxPortGigabitMasterSlaveStatus + , sFPPortGigabitMasterSlaveStatus + , transparentClock + , transparentClockVLAN + , transparentClockVID + , mainPSUPortAcceptedQLRx + , auxPortAcceptedQLRx + , sFPPortAcceptedQLRx + , mainPSUPortSyncERxStatus + , auxPortSyncERxStatus + , sFPPortSyncERxStatus + , nIDULanPortStatus + , nIDULanPortSpeedAndDuplex + , oOBPriorityQueueMapping + , nIDULanPortAutoNegotiation + , nIDULanPortAutoNegAdvertisement + , nIDULanPortAutoMdix + , nIDULanPortGigabitMasterSlaveStatus + , txMABFrames + , managementNetworkAccessEnabled + , secondDataPortPauseFrames + , secondDataBridgingStatus + , transparentClockPort + , ethernetPriorityQueueMapping + , l2CPPriorityQueueMapping + , iPDSCPPriorityQueueMapping + , mPLSTCPriorityQueueMapping + } + STATUS current + DESCRIPTION "The ethernet object group." + ::= { ptpGroups 6 } + + tDMGroup OBJECT-GROUP + OBJECTS { tDMInterfaceControl + , tDMInterfaceStatus + , tDMEnabledChannels + , tdmTableNumber + , tDMConfigurationMismatch + , lowestTDMModulationMode + , tDMChannelStatus + , tDMChannelLineCode + , tDMChannelCableLength + , tDMChannelLoopback + } + STATUS current + DESCRIPTION "The tDM object group." + ::= { ptpGroups 7 } + + licenseGroup OBJECT-GROUP + OBJECTS { regulatoryBand + , productVariant + , productName + , frequencyVariant + , sNMPv3Enable + , licenseVersion + , licenseUnitSerialNumber + , licenseIssueNumber + , licenseCountry + , licenseNumberOfRegulatoryBands + , licenseBandwidthCap + , licenseEncryption + , licenseSecurityLevel + , licenseGroupAccess + , licenseOOBManagementSupport + , licenseSFPPortSupport + , licenseAuxiliaryPortSupport + , licenseCapacity + , licenseMaxNumberOfTDMChannels + , licenseIEEE1588Support + , licenseSyncESupport + , licenseIPv6Support + , licenseMinimumFirmwareVersion + , licenseFullCapabilityTrialStatus + , licenseRemainingTrialPeriod + , licenseRemainingTrialPeriodAlarm + , capacityVariantMismatch + , licenseTDDSyncSupport + , licenseMaxLinkRange + , licenseTrialPeriod + , licenseRARSupport + , licenseRegulatoryBandsList + } + STATUS current + DESCRIPTION "The license object group." + ::= { ptpGroups 8 } + + managementGroup OBJECT-GROUP + OBJECTS { targetRange + , rangingMode + , installStatus + , installArmState + , tFTPServerPortNumber + , tFTPSoftwareUpgradeFileName + , tFTPStartSoftwareUpgrade + , tFTPSoftwareUpgradeStatus + , tFTPSoftwareUpgradeStatusText + , tFTPSoftwareUpgradeStatusAdditionalText + , hTTPAccessEnabled + , telnetAccessEnabled + , hTTPPortNumber + , hTTPSPortNumber + , telnetPortNumber + , hTTPSAccessEnabled + , tFTPServerInternetAddressType + , tFTPServerInternetAddress + , lowestDataModulationMode + , lowestSecondDataModulationMode + } + STATUS current + DESCRIPTION "The management object group." + ::= { ptpGroups 9 } + + phyControlGroup OBJECT-GROUP + OBJECTS { linkSymmetry + , userConfiguredMaxModulationMode + , linkModeOptimization + , txColorCode + , rxColorCode + , remoteMaximumTransmitPower + } + STATUS current + DESCRIPTION "The phyControl object group." + ::= { ptpGroups 10 } + + phyStatusGroup OBJECT-GROUP + OBJECTS { linkLoss + , receivePower + , vectorError + , transmitPower + , receiveChannel + , transmitChannel + , receiveFreqMHz + , transmitFreqMHz + , signalStrengthRatio + , receiveFreqKHz + , transmitFreqKHz + , rawReceivePower + , range + , receiveModulationMode + , transmitModulationMode + , searchState + } + STATUS current + DESCRIPTION "The phyStatus object group." + ::= { ptpGroups 12 } + + alarmsGroup OBJECT-GROUP + OBJECTS { unitOutOfCalibration + , incompatibleRegulatoryBands + , noWirelessChannelAvailable + , wirelessLinkDisabledWarning + , mainPSUPortDisabledWarning + , sFPError + , mainPSUPortConfigurationMismatch + , incompatibleMasterAndSlave + , tDDSynchronizationStatus + , auxPortDisabledWarning + , tDDSynchronizationAlarm + , linkModeOptimizationMismatch + , auxPortConfigurationMismatch + , secureModeAlarm + , dataBridgingStatusAlarm + , sFPPortDisabledWarning + , sFPPortConfigurationMismatch + , maxLinkRangeExceeded + , nIDULanPortDisabledWarning + , nIDULanPortConfigurationMismatch + , portAllocationMismatch + , secondDataBridgingStatusAlarm + , transparentClockSourcePortAlarm + } + STATUS current + DESCRIPTION "The alarms object group." + ::= { ptpGroups 13 } + + smtpGroup OBJECT-GROUP + OBJECTS { sMTPEmailAlert + , sMTPServerPortNumber + , sMTPSourceEmailAddress + , sMTPDestinationEmailAddress + , sMTPEnabledMessages + , sMTPServerInternetAddressType + , sMTPServerInternetAddress + } + STATUS current + DESCRIPTION "The smtp object group." + ::= { ptpGroups 15 } + + snmpControlGroup OBJECT-GROUP + OBJECTS { sNMPPortNumber + , sNMPCommunityString + , sNMPTrapTableNumber + , sNMPTrapVersion + , sNMPEnabledTraps + , enabledDiagnosticAlarms + , sNMPSendAllTrapsAtStartup + , sNMPTrapPortNumber + , sNMPTrapInternetAddressType + , sNMPTrapInternetAddress + , sNMPTrapReceiverEnabled + } + STATUS current + DESCRIPTION "The snmpControl object group." + ::= { ptpGroups 16 } + + sntpGroup OBJECT-GROUP + OBJECTS { sNTPState + , sNTPPollInterval + , sNTPSync + , sNTPLastSync + , systemClock + , timeZone + , daylightSaving + , sNTPPrimaryServer + , sNTPPrimaryServerDeadTime + , sNTPServerRetries + , sNTPServerTimeout + , sNTPServerTableNumber + , sNTPServerPortNumber + , sNTPServerStatus + , sNTPServerInternetAddressType + , sNTPServerInternetAddress + } + STATUS current + DESCRIPTION "The sntp object group." + ::= { ptpGroups 17 } + + resetGroup OBJECT-GROUP + OBJECTS { systemReset + } + STATUS current + DESCRIPTION "The reset object group." + ::= { ptpGroups 18 } + + versionsGroup OBJECT-GROUP + OBJECTS { softwareVersion + , hardwareVersion + , secondarySoftwareVersion + , bootVersion + } + STATUS current + DESCRIPTION "The versions object group." + ::= { ptpGroups 19 } + + pubStatsGroup OBJECT-GROUP + OBJECTS { receiveDataRate + , transmitDataRate + , aggregateDataRate + , wirelessLinkAvailability + , wirelessLinkStatus + , byteErrorRatio + , receiveModulationModeDetail + , dataBridgingAvailability + } + STATUS current + DESCRIPTION "The pubStats object group." + ::= { ptpGroups 20 } + + encryptionGroup OBJECT-GROUP + OBJECTS { encryptionAlgorithm + } + STATUS current + DESCRIPTION "The encryption object group." + ::= { ptpGroups 22 } + + tDDControlGroup OBJECT-GROUP + OBJECTS { tDDSynchronizationMode + } + STATUS current + DESCRIPTION "The tDDControl object group." + ::= { ptpGroups 23 } + + aAAControlGroup OBJECT-GROUP + OBJECTS { userTableNumber + , userName + , userRole + , userEnabled + , userPassword + } + STATUS current + DESCRIPTION "The aAAControl object group." + ::= { ptpGroups 25 } + + syslogControlGroup OBJECT-GROUP + OBJECTS { syslogClient + , syslogState + } + STATUS current + DESCRIPTION "The syslogControl object group." + ::= { ptpGroups 24 } + + routerProtocolsGroup OBJECT-GROUP + OBJECTS { microwaveAdaptiveBandwidth + , mABNominalModulationMode + , mABTransmissionInterval + , mABHoldoffPeriod + , mABMaintenanceLevel + , useVLANForMABProtocol + , mABProtocolVID + , mABProtocolVLANPriority + , mABState + , mABNominalTransmitCapacity + , mABCurrentTransmitCapacity + } + STATUS current + DESCRIPTION "The routerProtocols object group." + ::= { ptpGroups 26 } + + cableDiagnosticsGroup OBJECT-GROUP + OBJECTS { cableDiagnosticsPorts + , cableDiagnosticsControl + , cableDiagnosticsWarning + , cableDiagnosticsResultTableNumber + , cableDiagnosticsResultsDateTime + , cableDiagPair1Results + , cableDiagPair1Distance + , cableDiagPair2Results + , cableDiagPair2Distance + , cableDiagPair3Results + , cableDiagPair3Distance + , cableDiagPair4Results + , cableDiagPair4Distance + } + STATUS current + DESCRIPTION "The cableDiagnostics object group." + ::= { ptpGroups 27 } + + supplementaryGroup OBJECT-GROUP + OBJECTS { longitude + , latitude + , altitude + } + STATUS current + DESCRIPTION "The supplementary object group." + ::= { ptpGroups 96 } + + notificationsGroup NOTIFICATION-GROUP + NOTIFICATIONS { channelChangeTrap + , dfsImpulsiveInterferenceTrap + , mainPSUPortStatusTrap + , mainPSUPortDisabledWarningTrap + , mainPSUPortConfigurationMismatchTrap + , auxPortStatusTrap + , auxPortDisabledWarningTrap + , regulatoryBandTrap + , installStatusTrap + , installArmStateTrap + , unitOutOfCalibrationTrap + , auxPortPowerOverEthernetOutputStatusTrap + , incompatibleRegulatoryBandsTrap + , noWirelessChannelAvailableTrap + , wirelessLinkDisabledWarningTrap + , auxPortConfigurationMismatchTrap + , sFPErrorTrap + , sFPPortStatusTrap + , incompatibleMasterAndSlaveTrap + , sNTPSyncTrap + , tDDSynchronizationAlarmTrap + , sFPPortDisabledWarningTrap + , sFPPortConfigurationMismatchTrap + , linkModeOptimizationMismatchTrap + , tDMInterfaceStatusTrap + , tDMChannelStatusTrap + , tDMChannelLoopbackTrap + , nIDULanPortStatusTrap + , syslogStateTrap + , syslogLocalNearlyFullTrap + , syslogLocalWrappedTrap + , syslogClientTrap + , secureModeAlarmTrap + , dataBridgingStatusAlarmTrap + , licenseRemainingTrialPeriodAlarmTrap + , capacityVariantMismatchTrap + , maxLinkRangeExceededTrap + , tDMConfigurationMismatchTrap + , nIDULanPortDisabledWarningTrap + , nIDULanPortConfigurationMismatchTrap + , secondDataBridgingStatusAlarmTrap + , transparentClockSourcePortAlarmTrap + , portAllocationMismatchTrap + } + STATUS current + DESCRIPTION "The notifications group." + ::= { ptpGroups 99 } + + + DfsTableEntry ::= + SEQUENCE { dfsTableIndex INTEGER + , dfsMeans Integer32 + , dfsNineNinePointNinePercentiles Integer32 + , dfsPeaks Integer32 + } + + dfsTable OBJECT-TYPE + SYNTAX SEQUENCE OF DfsTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " A table storing a snapshot of various DFS measurements for each channel" + ::= { dfs 2 } + + dfsTableEntry OBJECT-TYPE + SYNTAX DfsTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table DfsTable" + INDEX { dfsTableIndex } + ::= { dfsTable 1 } + + EthernetPriorityTableEntry ::= + SEQUENCE { ethernetPriorityTableIndex INTEGER + , ethernetPriorityQueueMapping INTEGER + } + + ethernetPriorityTable OBJECT-TYPE + SYNTAX SEQUENCE OF EthernetPriorityTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " A priority queue mapping table. This is a list of packet queues indexed by Ethernet priority." + ::= { ethernet 15 } + + ethernetPriorityTableEntry OBJECT-TYPE + SYNTAX EthernetPriorityTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table EthernetPriorityTable" + INDEX { ethernetPriorityTableIndex } + ::= { ethernetPriorityTable 1 } + + L2CPPriorityTableEntry ::= + SEQUENCE { l2CPPriorityTableIndex INTEGER + , l2CPPriorityQueueMapping INTEGER + } + + l2CPPriorityTable OBJECT-TYPE + SYNTAX SEQUENCE OF L2CPPriorityTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " A priority queue mapping table. This is a list of packet queues indexed by L2CP priority." + ::= { ethernet 17 } + + l2CPPriorityTableEntry OBJECT-TYPE + SYNTAX L2CPPriorityTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table L2CPPriorityTable" + INDEX { l2CPPriorityTableIndex } + ::= { l2CPPriorityTable 1 } + + IPDSCPPriorityTableEntry ::= + SEQUENCE { iPDSCPPriorityTableIndex INTEGER + , iPDSCPPriorityQueueMapping INTEGER + } + + iPDSCPPriorityTable OBJECT-TYPE + SYNTAX SEQUENCE OF IPDSCPPriorityTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " A priority queue mapping table. This is a list of packet queues indexed by L3 IP DSCP priority." + ::= { ethernet 19 } + + iPDSCPPriorityTableEntry OBJECT-TYPE + SYNTAX IPDSCPPriorityTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table IPDSCPPriorityTable" + INDEX { iPDSCPPriorityTableIndex } + ::= { iPDSCPPriorityTable 1 } + + MPLSTCPriorityTableEntry ::= + SEQUENCE { mPLSTCPriorityTableIndex INTEGER + , mPLSTCPriorityQueueMapping INTEGER + } + + mPLSTCPriorityTable OBJECT-TYPE + SYNTAX SEQUENCE OF MPLSTCPriorityTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " A priority queue mapping table. This is a list of priority queues indexed by MPLS TC priority." + ::= { ethernet 21 } + + mPLSTCPriorityTableEntry OBJECT-TYPE + SYNTAX MPLSTCPriorityTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table MPLSTCPriorityTable" + INDEX { mPLSTCPriorityTableIndex } + ::= { mPLSTCPriorityTable 1 } + + TdmTableEntry ::= + SEQUENCE { tdmTableIndex INTEGER + , tDMChannelStatus INTEGER + , tDMChannelLineCode INTEGER + , tDMChannelCableLength INTEGER + , tDMChannelLoopback INTEGER + } + + tdmTable OBJECT-TYPE + SYNTAX SEQUENCE OF TdmTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " A table storing a configuration and status for each TDM channel" + ::= { tDM 5 } + + tdmTableEntry OBJECT-TYPE + SYNTAX TdmTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table TdmTable" + INDEX { tdmTableIndex } + ::= { tdmTable 1 } + + LicenseRegulatoryBandsTableEntry ::= + SEQUENCE { licenseRegulatoryBandsTableIndex INTEGER + , licenseRegulatoryBandsList INTEGER + } + + licenseRegulatoryBandsTable OBJECT-TYPE + SYNTAX SEQUENCE OF LicenseRegulatoryBandsTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= { license 18 } + + licenseRegulatoryBandsTableEntry OBJECT-TYPE + SYNTAX LicenseRegulatoryBandsTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table LicenseRegulatoryBandsTable" + INDEX { licenseRegulatoryBandsTableIndex } + ::= { licenseRegulatoryBandsTable 1 } + + SNMPTrapTableEntry ::= + SEQUENCE { sNMPTrapTableIndex INTEGER + , sNMPTrapPortNumber INTEGER + , sNMPTrapInternetAddressType INTEGER + , sNMPTrapInternetAddress InetAddress + , sNMPTrapReceiverEnabled INTEGER + } + + sNMPTrapTable OBJECT-TYPE + SYNTAX SEQUENCE OF SNMPTrapTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " SNMP trap configuration table." + ::= { snmpControl 4 } + + sNMPTrapTableEntry OBJECT-TYPE + SYNTAX SNMPTrapTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table SNMPTrapTable" + INDEX { sNMPTrapTableIndex } + ::= { sNMPTrapTable 1 } + + SNTPServerTableEntry ::= + SEQUENCE { sNTPServerTableIndex INTEGER + , sNTPServerPortNumber INTEGER + , sNTPServerStatus DisplayString + , sNTPServerInternetAddressType INTEGER + , sNTPServerInternetAddress InetAddress + } + + sNTPServerTable OBJECT-TYPE + SYNTAX SEQUENCE OF SNTPServerTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= { sntp 15 } + + sNTPServerTableEntry OBJECT-TYPE + SYNTAX SNTPServerTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table SNTPServerTable" + INDEX { sNTPServerTableIndex } + ::= { sNTPServerTable 1 } + + UserTableEntry ::= + SEQUENCE { userTableIndex INTEGER + , userName DisplayString + , userRole INTEGER + , userEnabled INTEGER + , userPassword DisplayString + } + + userTable OBJECT-TYPE + SYNTAX SEQUENCE OF UserTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " The User Table Control group contains objects specifically for user account management." + ::= { aAAControl 2 } + + userTableEntry OBJECT-TYPE + SYNTAX UserTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table UserTable" + INDEX { userTableIndex } + ::= { userTable 1 } + + CableDiagnosticsResultTableEntry ::= + SEQUENCE { cableDiagnosticsResultTableIndex INTEGER + , cableDiagnosticsResultsDateTime Integer32 + , cableDiagPair1Results INTEGER + , cableDiagPair1Distance Integer32 + , cableDiagPair2Results INTEGER + , cableDiagPair2Distance Integer32 + , cableDiagPair3Results INTEGER + , cableDiagPair3Distance Integer32 + , cableDiagPair4Results INTEGER + , cableDiagPair4Distance Integer32 + } + + cableDiagnosticsResultTable OBJECT-TYPE + SYNTAX SEQUENCE OF CableDiagnosticsResultTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= { cableDiagnostics 5 } + + cableDiagnosticsResultTableEntry OBJECT-TYPE + SYNTAX CableDiagnosticsResultTableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table CableDiagnosticsResultTable" + INDEX { cableDiagnosticsResultTableIndex } + ::= { cableDiagnosticsResultTable 1 } + + -- Dfs group attribute definitions + -- + dfsTableNumber OBJECT-TYPE + SYNTAX INTEGER (1..63) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of entries in the dfsTable" + ::= { dfs 1 } + + extendedSpectrumScanning OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Enables Extended Spectrum Scanning" + ::= { dfs 3 } + + -- DfsTable group attribute definitions + -- + dfsTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..63) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "used to index values in the dfsTable." + ::= { dfsTableEntry 1 } + + dfsMeans OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Snapshot of DFS means" + ::= { dfsTableEntry 2 } + + dfsNineNinePointNinePercentiles OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Snapshot of DFS 99.9 percentiles" + ::= { dfsTableEntry 3 } + + dfsPeaks OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Snapshot of DFS peaks" + ::= { dfsTableEntry 4 } + + -- Bridge group attribute definitions + -- + localPacketFiltering OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "When Local Packet Filtering is Enabled, the unit keeps + track of the port (Main, SFP, Aux or Wireless) on which a + packet with a given MAC source address destined to the + management agent has been received. This MAC address to + port mapping is then used in order to route any response + from the management agent to the right port. When Local + Packet Filtering is Disabled, any Ethernet packet from + the management agent is sent to all ports." + ::= { bridge 1 } + + -- Configuration group attribute definitions + -- + iPv4Address OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Internet protocol (IPv4) address. This address is used + by the family of Internet protocols to uniquely identify + the unit on a network." + ::= { configuration 1 } + + subnetMask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A subnet allows the flow of network traffic between + hosts to be segregated based on a network configuration. + By organizing hosts into logical groups, subnetting can + improve network security and performance." + ::= { configuration 2 } + + gatewayIPAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv4 address of a device on the current network that + acts as an IPv4 network gateway. A gateway acts as an + entrance / exit to packets from / to other networks" + ::= { configuration 3 } + + targetMACAddress OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(6)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "MAC address of the PTP wireless unit forming the other + end of the PTP link" + ::= { configuration 4 } + + masterSlaveMode OBJECT-TYPE + SYNTAX INTEGER { + master(0), + slave(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The PTP wireless link operates using a master and slave + relationship" + ::= { configuration 5 } + + maximumTransmitPower OBJECT-TYPE + SYNTAX INTEGER (-15..30) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum transmit power the wireless unit is permitted to + use when establishing and maintaining the wireless link. + This may be reduced during installation" + ::= { configuration 6 } + + antennaGain OBJECT-TYPE + SYNTAX INTEGER (130..610) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Antenna Gain. Expressed in 10ths of dBi." + ::= { configuration 7 } + + cableLoss OBJECT-TYPE + SYNTAX INTEGER (0..255) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Loss in the cable between the ODU and the antenna. + Expressed in 10ths of dB. NB: This attribute is ignored + for variants with an integral antenna." + ::= { configuration 8 } + + eIRP OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Effective Isotropic Radiated Power (EIRP) describes the + strength of the radio signal leaving the wireless unit. + Expressed in 10ths of dBm" + ::= { configuration 9 } + + channelBandwidth OBJECT-TYPE + SYNTAX INTEGER { + bw30MHz(0), + bw15MHz(1), + bw10MHz(2), + bw5MHz(3), + bw20MHz(4), + bw56MHz(5), + bw50MHz(6), + bw40MHz(7), + bw45MHz(8) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This control sets the bandwidth of the transmit and + receive radio channels" + ::= { configuration 11 } + + linkName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..63)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name of the PTP link allocated by the System + Administrator. Used to establish a connection with the + correct PTP wireless unit at the other end of the link. + NOTE: The link name MUST be the same at both ends of the + PTP link." + ::= { configuration 14 } + + siteName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..63)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This field contains a user-provided description of the + site name together with any additional notes" + ::= { configuration 15 } + + accessMethod OBJECT-TYPE + SYNTAX INTEGER { + linkAccess(0), + linkNameAccess(1), + groupAccess(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "ODUs must be configured in pairs before a link can be + established. The Access Method attribute determines how + the paired ODUs will recognise each other. For the Link + Access method, each ODU must be configured with Target + MAC Address equal to the MAC Address of the other unit. + For the Link Name Access method, both units must be + configured with the same Link Name. For the Group Access + method, both units must be configured with the same Group + ID." + ::= { configuration 16 } + + groupID OBJECT-TYPE + SYNTAX INTEGER (0..255) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "When Access Method is set to Group Access, the Group ID + identifies all the units belonging to the same group" + ::= { configuration 17 } + + iPv6Address OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..39)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Internet protocol (IPv6) address. This address is used + by the family of Internet protocols to uniquely identify + the unit on a network." + ::= { configuration 18 } + + iPVersion OBJECT-TYPE + SYNTAX INTEGER { + iPv4(0), + iPv6(1), + dualIPv4andIPv6(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IP protocol selection. Choice of IPv4, IPv6 or Dual." + ::= { configuration 20 } + + iPv6AutoConfiguredLinkLocalAddress OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..39)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The auto configured link local IPv6 address" + ::= { configuration 21 } + + iPv6PrefixLength OBJECT-TYPE + SYNTAX INTEGER (0..128) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IPv6 prefix length" + ::= { configuration 22 } + + iPv6GatewayAddress OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..39)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IPv6 address of a device on the current network that + is currently acting as an IPv6 network gateway. A gateway + acts as an entrance / exit to packets from / to other + networks." + ::= { configuration 23 } + + remoteInternetAddressType OBJECT-TYPE + SYNTAX INTEGER { + unknown(0), + ipv4(1), + ipv6(2), + ipv4z(3), + ipv6z(4), + unknown6(5), + unknown7(6), + unknown8(7), + unknown9(8), + unknown10(9), + unknown11(10), + unknown12(11), + unknown13(12), + unknown14(13), + unknown15(14), + unknown16(15), + dns(16) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of Internet address specified by the associated + remoteInternetAddressType." + ::= { configuration 24 } + + remoteInternetAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "INET address used to identify the peer wireless unit" + ::= { configuration 25 } + + subbandLowestFrequency OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Lowest center frequency of the subset of channels." + ::= { configuration 26 } + + subbandHighestFrequency OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Highest center frequency of the subset of channels." + ::= { configuration 27 } + + enableTransmission OBJECT-TYPE + SYNTAX INTEGER { + enabled(0), + muted(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control for enabling/disabling the radio transmitter of + the Master. Note: Use Web Properties to control this + feature." + ::= { configuration 28 } + + -- Ethernet group attribute definitions + -- + mainPSUPortAutoNegotiation OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This controls whether the local Ethernet interface + configuration is automatically negotiated or forced. Do + not use a forced setting together with auto negotiation + at the Ethernet link partner. If you want to run your + Ethernet link at a fixed speed and duplex then you would + normally leave auto negotiation enabled and only enable + the single Auto Neg Advertisement option that you want + the link to run in - FORCING ETHERNET CONFIGURATION IS A + LAST RESORT WHICH SHOULD ONLY BE PERFORMED IF YOU ARE + HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST + ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE ETHERNET + LINK PARTNER TO WHICH IT IS CONNECTED IDENTICALLY (THE + LINK PARTNER MUST NOT HAVE AUTO NEGOTIATION ENABLED + EITHER, OTHERWISE A DUPLEX MISMATCH WILL OCCUR). NB: The + new setting will only take effect after a system reboot." + ::= { ethernet 1 } + + mainPSUPortAutoNegAdvertisement OBJECT-TYPE + SYNTAX BITS { + negInvalid(2), + neg10MbpsHalfDuplex(3), + neg10MbpsFullDuplex(4), + neg100MbpsHalfDuplex(5), + neg100MbpsFullDuplex(6), + neg1000MbpsFullDuplex(7) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This sets the different Ethernet configurations that + will be advertised during auto negotiation. Note the new + setting will only take effect after a system reboot. + WARNING: Duplex mismatch may result if both ends of the + Ethernet link do not have the same settings. Do not auto + negotiation together with a fixed setting at the Ethernet + link partner. WARNING: Make sure that you select + option(s) that you know your connected equipment can + cater for!" + ::= { ethernet 2 } + + mainPSUPortAutoMdix OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This enables/disables the Auto MDI/MDIX capability. NB: + The new setting will only take effect after a system + reboot" + ::= { ethernet 3 } + + mainPSUPortStatus OBJECT-TYPE + SYNTAX INTEGER { + down(0), + copperLinkUp(1), + fiberLinkUp(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current status of the Main PSU Ethernet link. NB: a + change of state may generate an SNMP trap and/or SMTP + email alert" + ::= { ethernet 4 } + + mainPSUPortSpeedAndDuplex OBJECT-TYPE + SYNTAX INTEGER { + speed1000MbpsFullDuplex(0), + speed100MbpsFullDuplex(1), + speed100MbpsHalfDuplex(2), + speed10MbpsFullDuplex(3), + speed10MbpsHalfDuplex(4), + speedUnknown6(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current speed and duplex of the Main PSU Ethernet + link" + ::= { ethernet 5 } + + dataPortWirelessDownAlert OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "When enabled, this causes the Ethernet link to be + dropped briefly when the wireless link drops. This is so + that spanning tree algorithms can quickly detect that + there is a problem." + ::= { ethernet 6 } + + useVLANForManagementInterfaces OBJECT-TYPE + SYNTAX INTEGER { + noVLANTagging(0), + iEEE8021QTaggedCTagType8100(1), + iEEE8021adTaggedSTagorBTagType88a8(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This controls whether the management interfaces + (WWW/SNMP/SMTP/SNTP) use VLAN tags or not. NB: The new + setting will only take effect after a system reboot" + ::= { ethernet 7 } + + vLANManagementPriority OBJECT-TYPE + SYNTAX INTEGER { + p0(0), + p1(1), + p2(2), + p3(3), + p4(4), + p5(5), + p6(6), + p7(7) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This VLAN Priority (0-7) will be included in packets + generated by the management interfaces" + ::= { ethernet 8 } + + vLANManagementVID OBJECT-TYPE + SYNTAX INTEGER (0..4094) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This VLAN VID (0-4094) will be included in packets + generated by the management interfaces. Note the new + setting will only take effect after a system reboot" + ::= { ethernet 11 } + + auxPortStatus OBJECT-TYPE + SYNTAX INTEGER { + down(0), + copperLinkUp(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current status of the Aux Ethernet link. NB: a change of + state may generate an SNMP trap and/or SMTP email alert" + ::= { ethernet 12 } + + auxPortSpeedAndDuplex OBJECT-TYPE + SYNTAX INTEGER { + speed1000MbpsFullDuplex(0), + speed100MbpsFullDuplex(1), + speed100MbpsHalfDuplex(2), + speed10MbpsFullDuplex(3), + speed10MbpsHalfDuplex(4), + speedUnknown6(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current speed and duplex of the Aux Ethernet link" + ::= { ethernet 13 } + + ethernetPriorityTableNumber OBJECT-TYPE + SYNTAX INTEGER (9) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of entries in the vLANPriorityTable." + ::= { ethernet 14 } + + l2CPPriorityTableNumber OBJECT-TYPE + SYNTAX INTEGER (5) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of entries in the l2CPPriorityTable." + ::= { ethernet 16 } + + iPDSCPPriorityTableNumber OBJECT-TYPE + SYNTAX INTEGER (64) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of entries in the iPDSCPPriorityTable." + ::= { ethernet 18 } + + mPLSTCPriorityTableNumber OBJECT-TYPE + SYNTAX INTEGER (8) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of entries in the mPLSTCPriorityTable." + ::= { ethernet 20 } + + managementPortWirelessDownAlert OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "When enabled, this causes the management link to be + dropped briefly when the wireless link drops. This is so + that spanning tree algorithms can quickly detect that + there is a problem." + ::= { ethernet 23 } + + qOSPriorityScheme OBJECT-TYPE + SYNTAX INTEGER { + ethernet(0), + iPMPLS(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects classification based on fields in the Ethernet + header (Layer 2) or in the Network header (Layer 3). The + unit recognises two network layer protocols: IP and MPLS" + ::= { ethernet 24 } + + unknownNetworkPriorityQueueMapping OBJECT-TYPE + SYNTAX INTEGER { + q0(0), + q1(1), + q2(2), + q3(3), + q4(4), + q5(5), + q6(6), + q7(7) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Configures the classification of unknown network + protocols to an egress queue at the wireless port. + Unknown means something other than IP and MPLS" + ::= { ethernet 25 } + + dSCPManagementPriority OBJECT-TYPE + SYNTAX INTEGER (0..63) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This Differentiated Services Code Point value will be + inserted in the IP Header of all IP Datagrams transmitted + by the management interfaces" + ::= { ethernet 26 } + + dataBridgingStatus OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current status of Ethernet Data traffic bridging over + the wireless link" + ::= { ethernet 27 } + + mainPSUPortAllocation OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + dataOnly(1), + dataandInBandManagement(2), + outofBandLocalManagement(3), + outofBandRemoteManagement(4), + secondDataOnly(5), + secondDataandInBandManagement(6) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the service or services supported by the Main + PSU Ethernet port" + ::= { ethernet 28 } + + auxPortAllocation OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + dataOnly(1), + dataandInBandManagement(2), + outofBandLocalManagement(3), + outofBandRemoteManagement(4), + secondDataOnly(5), + secondDataandInBandManagement(6) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the service or services supported by the Aux + Ethernet port" + ::= { ethernet 29 } + + sFPPortAllocation OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + dataOnly(1), + dataandInBandManagement(2), + outofBandLocalManagement(3), + outofBandRemoteManagement(4), + secondDataOnly(5), + secondDataandInBandManagement(6) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the service or services supported by the SFP + Ethernet port" + ::= { ethernet 30 } + + dataPortPauseFrames OBJECT-TYPE + SYNTAX INTEGER { + tunnel(0), + discard(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Controls whether the bridge tunnels or discards Layer 2 + PAUSE frames arriving at the Data Port. Such frames are + identified by the destination MAC Address being equal to + 01-80-C2-00-00-01" + ::= { ethernet 31 } + + sFPPortAutoNegotiation OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This controls whether the local SFP Ethernet interface + configuration is automatically negotiated or forced. Do + not use a forced setting together with auto negotiation + at the Ethernet link partner. If you want to run your + Ethernet link at a fixed speed and duplex then you would + normally leave auto negotiation enabled and only enable + the single Auto Neg Advertisement option that you want + the link to run in - FORCING ETHERNET CONFIGURATION IS A + LAST RESORT WHICH SHOULD ONLY BE PERFORMED IF YOU ARE + HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST + ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE ETHERNET + LINK PARTNER TO WHICH IT IS CONNECTED IDENTICALLY (THE + LINK PARTNER MUST NOT HAVE AUTO NEGOTIATION ENABLED + EITHER, OTHERWISE A DUPLEX MISMATCH WILL OCCUR). NB: The + new setting will only take effect after a system reboot." + ::= { ethernet 32 } + + sFPPortAutoNegAdvertisement OBJECT-TYPE + SYNTAX BITS { + negInvalid(2), + neg10MbpsHalfDuplex(3), + neg10MbpsFullDuplex(4), + neg100MbpsHalfDuplex(5), + neg100MbpsFullDuplex(6), + neg1000MbpsFullDuplex(7) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This sets the different SFP Ethernet configurations that + will be advertised during auto negotiation. Note the new + setting will only take effect after a system reboot. + WARNING: Duplex mismatch may result if both ends of the + Ethernet link do not have the same settings. Do not auto + negotiation together with a fixed setting at the Ethernet + link partner. WARNING: Make sure that you select + option(s) that you know your connected equipment can + cater for!" + ::= { ethernet 33 } + + sFPPortAutoMdix OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This enables/disables the Auto MDI/MDIX capability. NB: + The new setting will only take effect after a system + reboot" + ::= { ethernet 34 } + + sFPPortStatus OBJECT-TYPE + SYNTAX INTEGER { + down(0), + copperLinkUp(1), + fiberLinkUp(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current status of the SFP Ethernet link. NB: a change of + state may generate an SNMP trap and/or SMTP email alert" + ::= { ethernet 35 } + + sFPPortSpeedAndDuplex OBJECT-TYPE + SYNTAX INTEGER { + speed1000MbpsFullDuplex(0), + speed100MbpsFullDuplex(1), + speed100MbpsHalfDuplex(2), + speed10MbpsFullDuplex(3), + speed10MbpsHalfDuplex(4), + speedUnknown6(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current speed and duplex of the SFP Ethernet link" + ::= { ethernet 36 } + + auxPortPowerOverEthernetOutput OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The state of the Power Over Ethernet (PoE) output of the + Aux port. Enabling PoE output may lead to system + instability; please refer to the User Guide before + enabling this control" + ::= { ethernet 37 } + + auxPortPowerOverEthernetOutputStatus OBJECT-TYPE + SYNTAX INTEGER { + poEOutputOn(0), + poEOutputDisabled(1), + poEOutputEnabledbutNotActiveErrororNoLoadPresent(2), + poEOutputOverloadError(3), + poEOutputOverTempError(4), + poEOutputErrorDetected(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current status of the Power Over Ethernet (PoE) output + of the Aux port" + ::= { ethernet 38 } + + syncETracking OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1), + internalTDMUseOnly(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether Synchronous Ethernet (SyncE) network + synchronization is enabled." + ::= { ethernet 39 } + + syncEEquipmentClock OBJECT-TYPE + SYNTAX INTEGER { + eECOption1(0), + eECOption2(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "EEC-Option 1 applies to synchronous Ethernet equipments + that are designed to interwork with networks optimized + for the 2048-kbit/s hierarchy. Corresponds to ITU-T G.813 + Option 1; EEC-Option 2 applies to synchronous Ethernet + equipments that are designed to interwork with networks + optimized for the 1544-kbit/s hierarchy. Corresponds to + Type IV clock from ITU-T G.812." + ::= { ethernet 40 } + + mainPSUPortQLRxOverwrite OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + qLPRS(1), + qLSTU(2), + qLPRC(3), + qLST2(4), + qLSSUAQLTNC(5), + qLSSUB(6), + qLST3E(7), + qLEEC2QLST3(8), + qLEEC1QLSEC(9), + qLSMC(10), + qLPROV(11), + qLDNUQLDUS(12) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Override for the Synchronous Ethernet (SyncE) received + Quality Level (QL) on the main PSU port." + ::= { ethernet 41 } + + mainPSUPortSSMTx OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether the Synchronous Ethernet (SyncE) + Quality Level (QL) is transmitted on the Main PSU port" + ::= { ethernet 42 } + + sFPPortSSMTx OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether the Synchronous Ethernet (SyncE) + Quality Level (QL) is transmitted on the SFP port" + ::= { ethernet 43 } + + auxPortSSMTx OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether the Synchronous Ethernet (SyncE) + Quality Level (QL) is transmitted on the Aux port" + ::= { ethernet 44 } + + syncETrackingState OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + acquiringWirelessLock(1), + freeRunning(2), + lockedLocalAcquiringHoldover(3), + lockedLocalHoldoverAcquired(4), + holdover(5), + lockedRemoteAcquiringHoldover(6), + lockedRemoteHoldoverAcquired(7) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current state of Synchronous Ethernet (SyncE) + network synchronization." + ::= { ethernet 45 } + + mainPSUPortQLRx OBJECT-TYPE + SYNTAX INTEGER { + none(0), + qLPRS(1), + qLSTU(2), + qLPRC(3), + qLST2(4), + qLSSUAQLTNC(5), + qLSSUB(6), + qLST3E(7), + qLEEC2QLST3(8), + qLEEC1QLSEC(9), + qLSMC(10), + qLPROV(11), + qLDNUQLDUS(12), + qLFAILED(13) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Synchronous Ethernet (SyncE) Quality Level (QL) + currently being received on the main PSU port." + ::= { ethernet 46 } + + auxPortQLRx OBJECT-TYPE + SYNTAX INTEGER { + none(0), + qLPRS(1), + qLSTU(2), + qLPRC(3), + qLST2(4), + qLSSUAQLTNC(5), + qLSSUB(6), + qLST3E(7), + qLEEC2QLST3(8), + qLEEC1QLSEC(9), + qLSMC(10), + qLPROV(11), + qLDNUQLDUS(12), + qLFAILED(13) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Synchronous Ethernet (SyncE) Quality Level (QL) + currently being received on the auxiliary port." + ::= { ethernet 47 } + + sFPPortQLRx OBJECT-TYPE + SYNTAX INTEGER { + none(0), + qLPRS(1), + qLSTU(2), + qLPRC(3), + qLST2(4), + qLSSUAQLTNC(5), + qLSSUB(6), + qLST3E(7), + qLEEC2QLST3(8), + qLEEC1QLSEC(9), + qLSMC(10), + qLPROV(11), + qLDNUQLDUS(12), + qLFAILED(13) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Synchronous Ethernet (SyncE) Quality Level (QL) + currently being received on the SFP port." + ::= { ethernet 48 } + + mainPSUPortQLTx OBJECT-TYPE + SYNTAX INTEGER { + none(0), + qLPRS(1), + qLSTU(2), + qLPRC(3), + qLST2(4), + qLSSUAQLTNC(5), + qLSSUB(6), + qLST3E(7), + qLEEC2QLST3(8), + qLEEC1QLSEC(9), + qLSMC(10), + qLPROV(11), + qLDNUQLDUS(12) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Synchronous Ethernet (SyncE) transmit Quality Level + (QL) of the main PSU port." + ::= { ethernet 49 } + + auxPortQLTx OBJECT-TYPE + SYNTAX INTEGER { + none(0), + qLPRS(1), + qLSTU(2), + qLPRC(3), + qLST2(4), + qLSSUAQLTNC(5), + qLSSUB(6), + qLST3E(7), + qLEEC2QLST3(8), + qLEEC1QLSEC(9), + qLSMC(10), + qLPROV(11), + qLDNUQLDUS(12) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Synchronous Ethernet (SyncE) transmit Quality Level + (QL) of the auxiliary port." + ::= { ethernet 50 } + + sFPPortQLTx OBJECT-TYPE + SYNTAX INTEGER { + none(0), + qLPRS(1), + qLSTU(2), + qLPRC(3), + qLST2(4), + qLSSUAQLTNC(5), + qLSSUB(6), + qLST3E(7), + qLEEC2QLST3(8), + qLEEC1QLSEC(9), + qLSMC(10), + qLPROV(11), + qLDNUQLDUS(12) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Synchronous Ethernet (SyncE) transmit Quality Level + (QL) of the SFP port." + ::= { ethernet 51 } + + mainPSUPortSyncEMasterSlaveStatus OBJECT-TYPE + SYNTAX INTEGER { + master(0), + slave(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The main PSU port Synchronous Ethernet (SyncE) + Master/Slave status" + ::= { ethernet 52 } + + auxPortSyncEMasterSlaveStatus OBJECT-TYPE + SYNTAX INTEGER { + master(0), + slave(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The auxiliary port Synchronous Ethernet (SyncE) + Master/Slave status" + ::= { ethernet 53 } + + sFPPortSyncEMasterSlaveStatus OBJECT-TYPE + SYNTAX INTEGER { + master(0), + slave(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The SFP port Synchronous Ethernet (SyncE) Master/Slave + status" + ::= { ethernet 54 } + + mainPSUPortGigabitMasterSlaveStatus OBJECT-TYPE + SYNTAX INTEGER { + master(0), + slave(1), + notApplicable(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The main PSU port Gigabit Ethernet Master/Slave status" + ::= { ethernet 55 } + + auxPortGigabitMasterSlaveStatus OBJECT-TYPE + SYNTAX INTEGER { + master(0), + slave(1), + notApplicable(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The auxiliary port Gigabit Ethernet Master/Slave status" + ::= { ethernet 56 } + + sFPPortGigabitMasterSlaveStatus OBJECT-TYPE + SYNTAX INTEGER { + master(0), + slave(1), + notApplicable(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The SFP port Gigabit Ethernet Master/Slave status" + ::= { ethernet 57 } + + transparentClock OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This control enables the Precision Time Protocol + (IEEE-1588) Transparent Clock. Once enabled the unit will + modify the correction field in PTP event messages to take + account of the time these frames have been resident in + this system. This will happen for all PTP frames at Layer + 2 & Layer 3 (IPv4 & IPv6) unless a transparent clock VLAN + is enabled." + ::= { ethernet 58 } + + transparentClockVLAN OBJECT-TYPE + SYNTAX INTEGER { + all(0), + sTagged(1), + cTagged(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "If All is selected then all PTP frames will have their + correction fields modified with the residence time. If an + S-TAG or C-TAG is selected, only frames with this VLAN + tag and matching the VLAN ID in the Transparent Clock VID + will have their correction fields modified." + ::= { ethernet 59 } + + transparentClockVID OBJECT-TYPE + SYNTAX INTEGER (0..4094) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The VLAN ID which frames must match if they are to be + corrected. Only valid when an S-TAG or C-TAG has been + selected." + ::= { ethernet 60 } + + mainPSUPortAcceptedQLRx OBJECT-TYPE + SYNTAX INTEGER { + none(0), + qLPRS(1), + qLSTU(2), + qLPRC(3), + qLST2(4), + qLSSUAQLTNC(5), + qLSSUB(6), + qLST3E(7), + qLEEC2QLST3(8), + qLEEC1QLSEC(9), + qLSMC(10), + qLPROV(11), + qLDNUQLDUS(12), + qLFAILED(13) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Synchronous Ethernet (SyncE) Quality Level (QL) + currently accepted (validated) on the main PSU port." + ::= { ethernet 61 } + + auxPortAcceptedQLRx OBJECT-TYPE + SYNTAX INTEGER { + none(0), + qLPRS(1), + qLSTU(2), + qLPRC(3), + qLST2(4), + qLSSUAQLTNC(5), + qLSSUB(6), + qLST3E(7), + qLEEC2QLST3(8), + qLEEC1QLSEC(9), + qLSMC(10), + qLPROV(11), + qLDNUQLDUS(12), + qLFAILED(13) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Synchronous Ethernet (SyncE) Quality Level (QL) + currently accepted (validated) on the auxiliary port." + ::= { ethernet 62 } + + sFPPortAcceptedQLRx OBJECT-TYPE + SYNTAX INTEGER { + none(0), + qLPRS(1), + qLSTU(2), + qLPRC(3), + qLST2(4), + qLSSUAQLTNC(5), + qLSSUB(6), + qLST3E(7), + qLEEC2QLST3(8), + qLEEC1QLSEC(9), + qLSMC(10), + qLPROV(11), + qLDNUQLDUS(12), + qLFAILED(13) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Synchronous Ethernet (SyncE) Quality Level (QL) + currently accepted (validated) on the SFP port." + ::= { ethernet 63 } + + mainPSUPortSyncERxStatus OBJECT-TYPE + SYNTAX INTEGER { + good(0), + waittoRestore(1), + failed(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Synchronous Ethernet (SyncE) Receive Status of the + main PSU port" + ::= { ethernet 64 } + + auxPortSyncERxStatus OBJECT-TYPE + SYNTAX INTEGER { + good(0), + waittoRestore(1), + failed(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Synchronous Ethernet (SyncE) Receive Status of the + auxiliary port" + ::= { ethernet 65 } + + sFPPortSyncERxStatus OBJECT-TYPE + SYNTAX INTEGER { + good(0), + waittoRestore(1), + failed(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Synchronous Ethernet (SyncE) Receive Status of the + SFP port" + ::= { ethernet 66 } + + nIDULanPortStatus OBJECT-TYPE + SYNTAX INTEGER { + down(0), + copperLinkUp(1), + fiberLinkUp(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current status of the NIDU LAN Ethernet link. NB: a + change of state may generate an SNMP trap and/or SMTP + email alert" + ::= { ethernet 67 } + + nIDULanPortSpeedAndDuplex OBJECT-TYPE + SYNTAX INTEGER { + speed1000MbpsFullDuplex(0), + speed100MbpsFullDuplex(1), + speed100MbpsHalfDuplex(2), + speed10MbpsFullDuplex(3), + speed10MbpsHalfDuplex(4), + speedUnknown6(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current speed and duplex of the Ethernet link to the + NIDU LAN Port" + ::= { ethernet 68 } + + oOBPriorityQueueMapping OBJECT-TYPE + SYNTAX INTEGER { + q0(0), + q1(1), + q2(2), + q3(3), + q4(4), + q5(5), + q6(6), + q7(7) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Configures the classification of traffic to an egress + queue at the wireless port" + ::= { ethernet 69 } + + nIDULanPortAutoNegotiation OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This controls whether the local Ethernet interface + configuration is automatically negotiated or forced. Do + not use a forced setting together with auto negotiation + at the Ethernet link partner. If you want to run your + Ethernet link at a fixed speed and duplex then you would + normally leave auto negotiation enabled and only enable + the single Auto Neg Advertisement option that you want + the link to run in - FORCING ETHERNET CONFIGURATION IS A + LAST RESORT WHICH SHOULD ONLY BE PERFORMED IF YOU ARE + HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST + ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE ETHERNET + LINK PARTNER TO WHICH IT IS CONNECTED IDENTICALLY (THE + LINK PARTNER MUST NOT HAVE AUTO NEGOTIATION ENABLED + EITHER, OTHERWISE A DUPLEX MISMATCH WILL OCCUR). NB: The + new setting will only take effect after a system reboot." + ::= { ethernet 70 } + + nIDULanPortAutoNegAdvertisement OBJECT-TYPE + SYNTAX BITS { + negInvalid(2), + neg10MbpsHalfDuplex(3), + neg10MbpsFullDuplex(4), + neg100MbpsHalfDuplex(5), + neg100MbpsFullDuplex(6), + neg1000MbpsFullDuplex(7) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This sets the different Ethernet configurations that + will be advertised during auto negotiation. Note the new + setting will only take effect after a system reboot. + WARNING: Duplex mismatch may result if both ends of the + Ethernet link do not have the same settings. Do not auto + negotiation together with a fixed setting at the Ethernet + link partner. WARNING: Make sure that you select + option(s) that you know your connected equipment can + cater for!" + ::= { ethernet 71 } + + nIDULanPortAutoMdix OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This enables/disables the Auto MDI/MDIX capability. NB: + The new setting will only take effect after a system + reboot" + ::= { ethernet 72 } + + nIDULanPortGigabitMasterSlaveStatus OBJECT-TYPE + SYNTAX INTEGER { + master(0), + slave(1), + notApplicable(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The NIDU LAN port Gigabit Ethernet Master/Slave status" + ::= { ethernet 73 } + + txMABFrames OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of MAB frames transmitted" + ::= { ethernet 74 } + + managementNetworkAccessEnabled OBJECT-TYPE + SYNTAX INTEGER { + no(0), + yes(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "When enabled the local Out-of-Band interface can be used + to access the remote management network. If not enabled + the local management agent can still be accessed from the + remote management network and the local Out-of-Band + interface" + ::= { ethernet 75 } + + secondDataPortPauseFrames OBJECT-TYPE + SYNTAX INTEGER { + tunnel(0), + discard(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Controls whether the bridge tunnels or discards Layer 2 + PAUSE frames arriving at the Second Data Service Port. + Such frames are identified by the destination MAC Address + being equal to 01-80-C2-00-00-01" + ::= { ethernet 76 } + + secondDataBridgingStatus OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current status of bridging Second Data Service Ethernet + traffic over the wireless link" + ::= { ethernet 80 } + + transparentClockPort OBJECT-TYPE + SYNTAX INTEGER { + mainPSU(0), + aux(1), + sFP(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IEEE 1588 Transparent Clock source" + ::= { ethernet 81 } + + -- EthernetPriorityTable group attribute definitions + -- + ethernetPriorityTableIndex OBJECT-TYPE + SYNTAX INTEGER { + p0(1), + p1(2), + p2(3), + p3(4), + p4(5), + p5(6), + p6(7), + p7(8), + untagged(9) + } + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Ethernet priority flag, used to index values in the + ethernetPriorityTable" + ::= { ethernetPriorityTableEntry 1 } + + ethernetPriorityQueueMapping OBJECT-TYPE + SYNTAX INTEGER { + q0(0), + q1(1), + q2(2), + q3(3), + q4(4), + q5(5), + q6(6), + q7(7) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Configures the classification of this Ethernet priority + (also known as IEEE 802.1p value) to an egress queue at + the wireless port" + ::= { ethernetPriorityTableEntry 2 } + + -- L2CPPriorityTable group attribute definitions + -- + l2CPPriorityTableIndex OBJECT-TYPE + SYNTAX INTEGER { + bridge(1), + mRP(2), + cFM(3), + rAPS(4), + eAPS(5) + } + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "L2CP priority flag, used to index values in the + l2CPPriorityTable" + ::= { l2CPPriorityTableEntry 1 } + + l2CPPriorityQueueMapping OBJECT-TYPE + SYNTAX INTEGER { + q0(0), + q1(1), + q2(2), + q3(3), + q4(4), + q5(5), + q6(6), + q7(7) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Configures the classification of this layer two control + protocol (L2CP) to an egress queue at the wireless port" + ::= { l2CPPriorityTableEntry 2 } + + -- IPDSCPPriorityTable group attribute definitions + -- + iPDSCPPriorityTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..64) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "IP DSCP priority flag, used to index values in the + iPDSCPPriorityTable" + ::= { iPDSCPPriorityTableEntry 1 } + + iPDSCPPriorityQueueMapping OBJECT-TYPE + SYNTAX INTEGER { + q0(0), + q1(1), + q2(2), + q3(3), + q4(4), + q5(5), + q6(6), + q7(7) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Configures the classification of this IP differentiated + services code point (DSCP) value to an egress queue at + the wireless port" + ::= { iPDSCPPriorityTableEntry 2 } + + -- MPLSTCPriorityTable group attribute definitions + -- + mPLSTCPriorityTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..8) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "MPLS TC priority flag, used to index values in the + mPLSTCPriorityTable" + ::= { mPLSTCPriorityTableEntry 1 } + + mPLSTCPriorityQueueMapping OBJECT-TYPE + SYNTAX INTEGER { + q0(0), + q1(1), + q2(2), + q3(3), + q4(4), + q5(5), + q6(6), + q7(7) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Configures the classification of this MPLS traffic class + (the field formerly known as EXP) to an egress queue at + the wireless port" + ::= { mPLSTCPriorityTableEntry 2 } + + -- TDM group attribute definitions + -- + tDMInterfaceControl OBJECT-TYPE + SYNTAX INTEGER { + none(0), + e1(1), + t1(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The line interface type. If this is set to 'None' then + the TDM interfaces are disabled, and the TDM settings + will be ignored." + ::= { tDM 1 } + + tDMInterfaceStatus OBJECT-TYPE + SYNTAX INTEGER { + ok(0), + connectedNotConfigured(1), + notConnected(2), + nIDUdetectedonAUXport(3), + error(4), + codeDownloadInProgress(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "@Current status of the connection to the TDM Box. A + state of 'Up' on a green background indicates that the + TDM Box is connected OK. When connecting a TDM Box only + the Main Ethernet port should be used" + ::= { tDM 2 } + + tDMEnabledChannels OBJECT-TYPE + SYNTAX INTEGER (0..8) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of TDM channels enabled in the system" + ::= { tDM 3 } + + tdmTableNumber OBJECT-TYPE + SYNTAX INTEGER (1..8) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of entries in the TdmTable" + ::= { tDM 4 } + + tDMConfigurationMismatch OBJECT-TYPE + SYNTAX INTEGER { + ok(0), + linetypemismatch(1), + enabledchannelsmismatch(2), + linetypeandenabledchannelsmismatch(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current status of the configuration of the TDM Box. A + state of 'Ok' on a green background indicates that the + TDM Box configuration is matched OK with the remote end." + ::= { tDM 6 } + + lowestTDMModulationMode OBJECT-TYPE + SYNTAX INTEGER { + modAcquisition(0), + modBpsk63percent(1), + modQpsk63percentSingle(2), + modTransient1(3), + modQpsk87percentSingle(4), + modTransient2(5), + mod16qam63percentSingleA(6), + modTransient3(7), + mod16qam87percentSingle(8), + modTransient4(9), + mod64qam75percentSingle(10), + modTransient5(11), + mod64qam92percentSingle(12), + modTransient6(13), + mod256qam81percentSingle(14), + mod16qam63percentSingleB(15), + mod16qam63percentDual(16), + modTransient7(17), + mod16qam87percentDual(18), + modTransient8(19), + mod64qam75percentDual(20), + modTransient9(21), + mod64qam92percentDual(22), + modTransient10(23), + mod256qam81percentDual(24) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The lowest modulation mode at which tdm data will be + sent. The effective lowest modulation mode is displayed + in the TDM Configuration page" + ::= { tDM 7 } + + -- TdmTable group attribute definitions + -- + tdmTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..8) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "TDM Channel flag, used to index channels in the + TdmTable" + ::= { tdmTableEntry 1 } + + tDMChannelStatus OBJECT-TYPE + SYNTAX INTEGER { + up(0), + noSignalLocal(1), + noSignalRemote(2), + noSignalLocalandRemote(3), + remoteTiming(4), + noSignalLocalandRemoteTiming(5), + disabled(6) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current status of the TDM channels. A value of 0 + indicates that a TDM channel is established" + ::= { tdmTableEntry 2 } + + tDMChannelLineCode OBJECT-TYPE + SYNTAX INTEGER { + aMI(0), + b8ZSorHDB3(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The line code setting of the TDM interfaces. This must + match the setting of the device connected to an + interface" + ::= { tdmTableEntry 3 } + + tDMChannelCableLength OBJECT-TYPE + SYNTAX INTEGER { + feet133(0), + feet266(1), + feet399(2), + feet533(3), + feet655(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The lengths of the cables connected to the TDM + interfaces, measured in feet" + ::= { tdmTableEntry 4 } + + tDMChannelLoopback OBJECT-TYPE + SYNTAX INTEGER { + none(0), + copper(1), + wireless(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The loopback status of TDM channels. This is intended + for installation testing and should be set to 'None' for + normal operation. The wire connections to a unit can be + tested by applying a 'Copper' loopback to the local unit. + The wireless connection to the remote unit can be tested + by applying a 'Wireless' loopback to the remote unit with + no loopback on the local unit. NB: a change of state may + generate an SNMP trap and/or SMTP email alert" + ::= { tdmTableEntry 5 } + + -- License group attribute definitions + -- + regulatoryBand OBJECT-TYPE + SYNTAX INTEGER { + regInvalid(0), + reg158GHz(1), + reg258GHz(2), + reg358GHz(3), + reg458GHz(4), + reg558GHz(5), + reg658GHz(6), + reg754GHzUnrestrictedEIRPwithDFS(7), + reg854GHzUnrestrictedEIRP(8), + reg9(9), + reg1058GHz(10), + reg1158GHz(11), + reg1254GHzFCCUNII2C(12), + reg1354GHz(13), + reg1449GHzPublicSafety(14), + reg15(15), + reg1659GHz(16), + reg1759GHz(17), + reg1849GHzPublicSafety(18), + reg1958GHz(19), + reg2054GHz(20), + reg2154GHz(21), + reg2258GHz(22), + reg23(23), + reg2458GHz(24), + reg2558GHzETSI(25), + reg2654GHzETSI(26), + reg2758GHz(27), + reg2858GHz(28), + reg2958GHzUnrestrictedEIRPwithDFSandRTTT(29), + reg3054GHz(30), + reg3158GHz(31), + reg3249GHzLicensed(32), + reg3349GHzETSIBroadbandDisasterRelief(33), + reg3458GHz(34), + reg3558GHzUnrestrictedEIRP(35), + reg3654GHz(36), + reg3758GHz(37), + reg3852GHzFCCUNII2A(38), + reg3951GHzETSIBroadbandDisasterRelief(39), + reg4054GHz(40), + reg4154GHz(41), + reg4254GHz(42), + reg4354GHz(43), + reg4458GHz(44), + reg4558GHz(45), + reg4658GHz(46), + reg4758GHz(47), + reg4858GHz(48), + reg4958GHz(49), + reg5058GHz(50), + reg5158GHz(51), + reg5258GHz(52), + reg5358GHz(53), + reg5458GHz(54), + reg5558GHz(55), + reg5654GHz(56), + reg5754GHz(57), + reg5858GHz(58), + reg5958GHz(59), + reg6058GHz(60), + reg6149GHz(61), + reg6252GHz(62), + reg6352GHz(63), + reg6451GHz(64), + reg6551GHz(65), + reg6651GHz(66), + reg6752GHz(67), + reg6852GHz(68), + reg6952GHz(69), + reg7052GHz(70), + reg7152GHz(71), + reg7252GHz(72), + reg7352GHz(73), + reg7452GHz(74), + reg7552GHz(75), + reg7652GHz(76), + reg7752GHz(77), + reg7849GHz(78), + reg7954GHz(79), + reg8049GHz(80), + reg8147GHz(81), + reg8247GHz(82), + reg8352GHz(83), + reg8451GHzFCCUNII1(84), + reg8552GHzFCCUNII12A(85), + reg8654GHzFCCUNII2A2C(86), + reg8758GHz(87), + reg8849GHz(88), + reg8949GHz(89), + reg9054GHzFCCUNII2CParabolicantenna(90), + reg9152GHzFCCUNII2AParabolicantenna(91), + reg9251GHzFCCUNII1Parabolicantenna(92), + reg9349GHz(93), + reg94(94), + reg95(95), + reg96(96), + reg97(97), + reg98(98), + reg99(99), + reg100(100), + reg101(101), + reg102(102), + reg103(103), + reg104(104), + reg105(105), + reg106(106), + reg107(107), + reg108(108), + reg109(109), + reg110(110), + reg111(111), + reg112(112), + reg113(113), + reg114(114), + reg115(115), + reg116(116), + reg117(117), + reg118(118), + reg119(119), + reg120(120), + reg121(121), + reg122(122), + reg123(123), + reg124(124), + reg125(125), + reg126(126), + reg127(127), + reg128(128), + reg129(129), + reg130(130), + reg131(131), + reg132(132), + reg133(133), + reg134(134), + reg135(135), + reg136(136), + reg137(137), + reg138(138), + reg139(139), + reg140(140), + reg141(141), + reg142(142), + reg143(143), + reg144(144), + reg145(145), + reg146(146), + reg147(147), + reg148(148), + reg149(149), + reg150(150), + reg151(151), + reg152(152), + reg153(153), + reg154(154), + reg155(155), + reg156(156), + reg157(157), + reg158(158), + reg159(159), + reg160(160), + reg161(161), + reg162(162), + reg163(163), + reg164(164), + reg165(165), + reg166(166), + reg167(167), + reg168(168), + reg169(169), + reg170(170), + reg171(171), + reg172(172), + reg173(173), + reg174(174), + reg175(175), + reg176(176), + reg177(177), + reg178(178), + reg179(179), + reg180(180), + reg181(181), + reg182(182), + reg183(183), + reg184(184), + reg185(185), + reg186(186), + reg187(187), + reg188(188), + reg189(189), + reg190(190), + reg191(191), + reg192(192), + reg193(193), + reg194(194), + reg195(195), + reg196(196), + reg197(197), + reg198(198), + reg199(199), + reg200(200), + reg201(201), + reg202(202), + reg203(203), + reg204(204), + reg205(205), + reg206(206), + reg207(207), + reg208(208), + reg209(209), + reg210(210), + reg211(211), + reg212(212), + reg213(213), + reg214(214), + reg215(215), + reg216(216), + reg217(217), + reg218(218), + reg219(219), + reg220(220), + reg221(221), + reg222(222), + reg223(223), + reg224(224), + reg225(225), + reg226(226), + reg227(227), + reg228(228), + reg229(229), + reg230(230), + reg231(231), + reg232(232), + reg233(233), + reg234(234), + reg235(235), + reg236(236), + reg237(237), + reg238(238), + reg239(239), + reg240(240), + reg241(241), + reg242(242), + reg243(243), + reg244(244), + reg245(245), + reg246(246), + reg247(247), + reg248(248), + reg249(249), + reg250(250), + reg251(251), + reg252(252), + reg253(253), + reg254(254), + reg255(255) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Regulatory Band prohibits the wireless unit from + operating outside the regulated limits. An invalid + Regulatory Band may be caused by a missing or incorrect + License Key, a corrupt MAC Address or an attempt to + configure a Regulatory Band not allowed by the License + Key. NB: a change of state may generate an SNMP trap + and/or SMTP email alert." + ::= { license 1 } + + productVariant OBJECT-TYPE + SYNTAX INTEGER { + pTPxx400Full(0), + pTPxx400Deprecated1(1), + pTPxx400Deprecated2(2), + pTPxx400Lite(3), + spare1(4), + pTPxx300(5), + spare2(6), + spare3(7), + pTPxx500FullDeprecated(8), + pTPxx500LiteDeprecated(9), + pTPxx500(10), + pTPxx600Lite(11), + pTPxx600Full(12), + pTPxx650(13), + spare6(14), + pTP800(15) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The product variant" + ::= { license 2 } + + productName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..63)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of the product variant" + ::= { license 3 } + + frequencyVariant OBJECT-TYPE + SYNTAX INTEGER { + freq5GHz(0), + freq4GHz(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The hardware frequency variant" + ::= { license 5 } + + sNMPv3Enable OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "SNMPv3 availability control" + ::= { license 9 } + + licenseVersion OBJECT-TYPE + SYNTAX INTEGER (1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The license key version." + ::= { license 12 } + + licenseUnitSerialNumber OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..11)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unit serial number." + ::= { license 13 } + + licenseIssueNumber OBJECT-TYPE + SYNTAX INTEGER (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The license key issue number for this unit." + ::= { license 15 } + + licenseCountry OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..103)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The country in which this unit is licensed to operate." + ::= { license 16 } + + licenseNumberOfRegulatoryBands OBJECT-TYPE + SYNTAX INTEGER (0..32) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of regulatory bands for which the unit is + licensed to operate." + ::= { license 17 } + + licenseBandwidthCap OBJECT-TYPE + SYNTAX INTEGER (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The wireless link bandwidth cap in MHz. Zero indicates + no bandwidth cap." + ::= { license 20 } + + licenseEncryption OBJECT-TYPE + SYNTAX INTEGER { + none(0), + aESRijndael(1), + aES192bitRijndael(2), + aES256bitRijndael(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The license key encryption algorithms available." + ::= { license 21 } + + licenseSecurityLevel OBJECT-TYPE + SYNTAX INTEGER { + normal(0), + fIPS(1), + uCAPL(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The license key security level." + ::= { license 22 } + + licenseGroupAccess OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The license key group access setting." + ::= { license 23 } + + licenseOOBManagementSupport OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The license key Out-Of-Band (OOB) support setting." + ::= { license 24 } + + licenseSFPPortSupport OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The license key Ethernet SFP Port support setting." + ::= { license 25 } + + licenseAuxiliaryPortSupport OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The license key Ethernet Auxiliary Port support + setting." + ::= { license 26 } + + licenseCapacity OBJECT-TYPE + SYNTAX INTEGER { + full(0), + mid(1), + lite(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The license key capacity" + ::= { license 27 } + + licenseMaxNumberOfTDMChannels OBJECT-TYPE + SYNTAX INTEGER (0..8) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The license key maximum TDM channels setting. Zero + indicates TDM not available." + ::= { license 28 } + + licenseIEEE1588Support OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The license key IEEE-1588 support setting." + ::= { license 29 } + + licenseSyncESupport OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The license key SyncE support setting." + ::= { license 30 } + + licenseIPv6Support OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The license key IPv6 support setting." + ::= { license 31 } + + licenseMinimumFirmwareVersion OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..23)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum firmware version required to support this + license key." + ::= { license 32 } + + licenseFullCapabilityTrialStatus OBJECT-TYPE + SYNTAX INTEGER { + available(0), + active(1), + inactive(2), + expired(3), + unavailable(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The license key full capability trial period status." + ::= { license 33 } + + licenseRemainingTrialPeriod OBJECT-TYPE + SYNTAX INTEGER (0..31536000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The remaining time for the license key full capability + trial period." + ::= { license 34 } + + licenseRemainingTrialPeriodAlarm OBJECT-TYPE + SYNTAX INTEGER { + fullCapabilityTrialNotActiveOrMoreThan7DaysRemaining(0), + fullCapabilityTrialExpiringInLessThan7Days(1), + fullCapabilityTrialExpiringInLessThan6Days(2), + fullCapabilityTrialExpiringInLessThan5Days(3), + fullCapabilityTrialExpiringInLessThan4Days(4), + fullCapabilityTrialExpiringInLessThan3Days(5), + fullCapabilityTrialExpiringInLessThan2Days(6), + fullCapabilityTrialExpiringInLessThan1Day(7), + fullCapabilityTrialHasExpired(8) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "If the full capability trial license period is about to + expire then purchase a license upgrade from your + reseller." + ::= { license 35 } + + capacityVariantMismatch OBJECT-TYPE + SYNTAX INTEGER { + noError(0), + mismatchDetected(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The remote node of this link has a lower link capacity. + Operating with a reduced effective link capacity." + ::= { license 36 } + + licenseTDDSyncSupport OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The license key TDD Synchronization support setting." + ::= { license 37 } + + licenseMaxLinkRange OBJECT-TYPE + SYNTAX INTEGER (0..1999) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum licensed range for the wireless link in tenths + of km. A value of zero indicates that the maximum link + range is not limited by the license." + ::= { license 38 } + + licenseTrialPeriod OBJECT-TYPE + SYNTAX INTEGER (0..365) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The license key maximum trial period, in days." + ::= { license 39 } + + licenseRARSupport OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + mAB(1), + dLEP(2), + mABandDLEP(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The license key Radio Aware Routing support setting." + ::= { license 40 } + + -- LicenseRegulatoryBandsTable group attribute definitions + -- + licenseRegulatoryBandsTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..32) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "License regulatory bands, used to index the + LicenseRegulatoryBandsTable." + ::= { licenseRegulatoryBandsTableEntry 1 } + + licenseRegulatoryBandsList OBJECT-TYPE + SYNTAX INTEGER { + regInvalid(0), + reg158GHz(1), + reg258GHz(2), + reg358GHz(3), + reg458GHz(4), + reg558GHz(5), + reg658GHz(6), + reg754GHzUnrestrictedEIRPwithDFS(7), + reg854GHzUnrestrictedEIRP(8), + reg9(9), + reg1058GHz(10), + reg1158GHz(11), + reg1254GHzFCCUNII2C(12), + reg1354GHz(13), + reg1449GHzPublicSafety(14), + reg15(15), + reg1659GHz(16), + reg1759GHz(17), + reg1849GHzPublicSafety(18), + reg1958GHz(19), + reg2054GHz(20), + reg2154GHz(21), + reg2258GHz(22), + reg23(23), + reg2458GHz(24), + reg2558GHzETSI(25), + reg2654GHzETSI(26), + reg2758GHz(27), + reg2858GHz(28), + reg2958GHzUnrestrictedEIRPwithDFSandRTTT(29), + reg3054GHz(30), + reg3158GHz(31), + reg3249GHzLicensed(32), + reg3349GHzETSIBroadbandDisasterRelief(33), + reg3458GHz(34), + reg3558GHzUnrestrictedEIRP(35), + reg3654GHz(36), + reg3758GHz(37), + reg3852GHzFCCUNII2A(38), + reg3951GHzETSIBroadbandDisasterRelief(39), + reg4054GHz(40), + reg4154GHz(41), + reg4254GHz(42), + reg4354GHz(43), + reg4458GHz(44), + reg4558GHz(45), + reg4658GHz(46), + reg4758GHz(47), + reg4858GHz(48), + reg4958GHz(49), + reg5058GHz(50), + reg5158GHz(51), + reg5258GHz(52), + reg5358GHz(53), + reg5458GHz(54), + reg5558GHz(55), + reg5654GHz(56), + reg5754GHz(57), + reg5858GHz(58), + reg5958GHz(59), + reg6058GHz(60), + reg6149GHz(61), + reg6252GHz(62), + reg6352GHz(63), + reg6451GHz(64), + reg6551GHz(65), + reg6651GHz(66), + reg6752GHz(67), + reg6852GHz(68), + reg6952GHz(69), + reg7052GHz(70), + reg7152GHz(71), + reg7252GHz(72), + reg7352GHz(73), + reg7452GHz(74), + reg7552GHz(75), + reg7652GHz(76), + reg7752GHz(77), + reg7849GHz(78), + reg7954GHz(79), + reg8049GHz(80), + reg8147GHz(81), + reg8247GHz(82), + reg8352GHz(83), + reg8451GHzFCCUNII1(84), + reg8552GHzFCCUNII12A(85), + reg8654GHzFCCUNII2A2C(86), + reg8758GHz(87), + reg8849GHz(88), + reg8949GHz(89), + reg9054GHzFCCUNII2CParabolicantenna(90), + reg9152GHzFCCUNII2AParabolicantenna(91), + reg9251GHzFCCUNII1Parabolicantenna(92), + reg9349GHz(93), + reg94(94), + reg95(95), + reg96(96), + reg97(97), + reg98(98), + reg99(99), + reg100(100), + reg101(101), + reg102(102), + reg103(103), + reg104(104), + reg105(105), + reg106(106), + reg107(107), + reg108(108), + reg109(109), + reg110(110), + reg111(111), + reg112(112), + reg113(113), + reg114(114), + reg115(115), + reg116(116), + reg117(117), + reg118(118), + reg119(119), + reg120(120), + reg121(121), + reg122(122), + reg123(123), + reg124(124), + reg125(125), + reg126(126), + reg127(127), + reg128(128), + reg129(129), + reg130(130), + reg131(131), + reg132(132), + reg133(133), + reg134(134), + reg135(135), + reg136(136), + reg137(137), + reg138(138), + reg139(139), + reg140(140), + reg141(141), + reg142(142), + reg143(143), + reg144(144), + reg145(145), + reg146(146), + reg147(147), + reg148(148), + reg149(149), + reg150(150), + reg151(151), + reg152(152), + reg153(153), + reg154(154), + reg155(155), + reg156(156), + reg157(157), + reg158(158), + reg159(159), + reg160(160), + reg161(161), + reg162(162), + reg163(163), + reg164(164), + reg165(165), + reg166(166), + reg167(167), + reg168(168), + reg169(169), + reg170(170), + reg171(171), + reg172(172), + reg173(173), + reg174(174), + reg175(175), + reg176(176), + reg177(177), + reg178(178), + reg179(179), + reg180(180), + reg181(181), + reg182(182), + reg183(183), + reg184(184), + reg185(185), + reg186(186), + reg187(187), + reg188(188), + reg189(189), + reg190(190), + reg191(191), + reg192(192), + reg193(193), + reg194(194), + reg195(195), + reg196(196), + reg197(197), + reg198(198), + reg199(199), + reg200(200), + reg201(201), + reg202(202), + reg203(203), + reg204(204), + reg205(205), + reg206(206), + reg207(207), + reg208(208), + reg209(209), + reg210(210), + reg211(211), + reg212(212), + reg213(213), + reg214(214), + reg215(215), + reg216(216), + reg217(217), + reg218(218), + reg219(219), + reg220(220), + reg221(221), + reg222(222), + reg223(223), + reg224(224), + reg225(225), + reg226(226), + reg227(227), + reg228(228), + reg229(229), + reg230(230), + reg231(231), + reg232(232), + reg233(233), + reg234(234), + reg235(235), + reg236(236), + reg237(237), + reg238(238), + reg239(239), + reg240(240), + reg241(241), + reg242(242), + reg243(243), + reg244(244), + reg245(245), + reg246(246), + reg247(247), + reg248(248), + reg249(249), + reg250(250), + reg251(251), + reg252(252), + reg253(253), + reg254(254), + reg255(255) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The list of regulatory bands for which the unit is + licensed to operate. A regulatory band prohibits the + wireless unit from operating outside the regulated + limits. An invalid regulatory band indicates a corrupted + license key. NB: a change of state may generate an SNMP + trap and/or SMTP email alert." + ::= { licenseRegulatoryBandsTableEntry 2 } + + -- Management group attribute definitions + -- + targetRange OBJECT-TYPE + SYNTAX INTEGER (0..2000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Initial target range used in installation +/-1, + expressed in tenths of a kilometer. When Auto-Ranging + this must be set to 0" + ::= { management 1 } + + rangingMode OBJECT-TYPE + SYNTAX INTEGER { + auto0to40km(0), + auto0to100km(1), + auto0to200km(2), + targetRange(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Type of ranging to use during installation, either + Auto-Ranging or use a selectable Target Range" + ::= { management 2 } + + installStatus OBJECT-TYPE + SYNTAX INTEGER { + ok(0), + wrongPeer(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A non-zero value indicates that signalling was received + with the wrong MAC address or a mismatched link name. NB: + It is very unusual to detect this, because units with + mis-configured Target MAC Address will normally fail to + establish a wireless link. However, rare circumstances + may establish a partial wireless link and detect this + situation. NB: A non-zero value on start-up, or a change + of value during operation, may generate an SNMP trap + and/or SMTP email alert" + ::= { management 3 } + + installArmState OBJECT-TYPE + SYNTAX INTEGER { + disarmed(0), + armed(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates if the unit is being installed. NB: a change + of state may generate an SNMP trap and/or SMTP email + alert" + ::= { management 4 } + + tFTPServerPortNumber OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The port number of the TFTP Server from which the TFTP + Software Upgrade File Name will be retrieved" + ::= { management 6 } + + tFTPSoftwareUpgradeFileName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..127)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Filename of the Software Upgrade to be loaded from the + TFTP Server" + ::= { management 7 } + + tFTPStartSoftwareUpgrade OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Write '1' to this attribute to start the TFTP software + upgrade process. The attribute will be reset to 0 when + the upgrade process has finished. Continuing with the + software upgrade will cause spectrum management (DSO) + channel metrics collection to stop. The wireless unit + will no longer search for the optimal operational radio + channel. The performance of this wireless link may + deterioate over time. If operating in a regulatory band + where RADAR detection is mandatory you must complete the + software upgrade and reboot the unit. Channel metrics + collection will only be restarted after the wireless unit + has been rebooted" + ::= { management 8 } + + tFTPSoftwareUpgradeStatus OBJECT-TYPE + SYNTAX INTEGER { + idle(0), + uploadinprogress(1), + uploadsuccessfulprogrammingFLASH(2), + upgradesuccessfulreboottorunthenewsoftwareimage(3), + upgradefailed(4), + upgradewarning(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current status of the TFTP Software upgrade process" + ::= { management 9 } + + tFTPSoftwareUpgradeStatusText OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Descriptive text describing the status of the TFTP + Software upgrade process, including any error details" + ::= { management 10 } + + tFTPSoftwareUpgradeStatusAdditionalText OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Any additional text describing the status of the TFTP + Software upgrade process, including any error details" + ::= { management 11 } + + hTTPAccessEnabled OBJECT-TYPE + SYNTAX INTEGER { + no(0), + yes(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This controls whether or not HTTP access is enabled, + i.e. if this is disabled (0) then the unit will not + respond to any requests on the HTTP port. Remote + management via HTTPS is not affected by this setting. Any + change in this setting will not take effect until the + unit has been rebooted. (Factory default = Enabled)" + ::= { management 12 } + + telnetAccessEnabled OBJECT-TYPE + SYNTAX INTEGER { + no(0), + yes(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This controls whether or not Telnet access is enabled, + i.e. if this is disabled (0) then the unit will not + respond to any requests on the TELNET port. Any change in + this setting will not take effect until the unit has been + rebooted. (Factory default = Disabled)" + ::= { management 13 } + + hTTPPortNumber OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This controls the port number for HTTP access. A value + of zero will use the default port number. Any change in + this setting will not take effect until the unit has been + rebooted. (Factory default = 80)" + ::= { management 14 } + + hTTPSPortNumber OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This controls the port number for HTTPS access. A value + of zero will use the default port number. Availability of + HTTPS is controlled via the License Key. Any change in + this setting will not take effect until the unit has been + rebooted. (Factory default = 443)" + ::= { management 15 } + + telnetPortNumber OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This controls the port number for TELNET access. A value + of zero will use the default port number. Any change in + this setting will not take effect until the unit has been + rebooted. (Factory default = 23)" + ::= { management 16 } + + hTTPSAccessEnabled OBJECT-TYPE + SYNTAX INTEGER { + no(0), + yes(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This controls whether or not HTTPS access is enabled, + i.e. if this is disabled (0) then the unit will not + respond to any requests on the HTTPS port. Remote + management via HTTP is not affected by this setting. Any + change in this setting will not take effect until the + unit has been rebooted. (Factory default = Enabled)" + ::= { management 17 } + + tFTPServerInternetAddressType OBJECT-TYPE + SYNTAX INTEGER { + unknown(0), + ipv4(1), + ipv6(2), + ipv4z(3), + ipv6z(4), + unknown6(5), + unknown7(6), + unknown8(7), + unknown9(8), + unknown10(9), + unknown11(10), + unknown12(11), + unknown13(12), + unknown14(13), + unknown15(14), + unknown16(15), + dns(16) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of Internet address specified by the associated + tFTPServerInternetAddress." + ::= { management 18 } + + tFTPServerInternetAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "INET address of the TFTP Server from which the TFTP + Software Upgrade File Name will be retrieved" + ::= { management 19 } + + lowestDataModulationMode OBJECT-TYPE + SYNTAX INTEGER { + modAcquisition(0), + modBpsk63percent(1), + modQpsk63percentSingle(2), + modTransient1(3), + modQpsk87percentSingle(4), + modTransient2(5), + mod16qam63percentSingleA(6), + modTransient3(7), + mod16qam87percentSingle(8), + modTransient4(9), + mod64qam75percentSingle(10), + modTransient5(11), + mod64qam92percentSingle(12), + modTransient6(13), + mod256qam81percentSingle(14), + mod16qam63percentSingleB(15), + mod16qam63percentDual(16), + modTransient7(17), + mod16qam87percentDual(18), + modTransient8(19), + mod64qam75percentDual(20), + modTransient9(21), + mod64qam92percentDual(22), + modTransient10(23), + mod256qam81percentDual(24) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The lowest modulation mode at which Ethernet Data + traffic will be bridged over the wireless link" + ::= { management 20 } + + lowestSecondDataModulationMode OBJECT-TYPE + SYNTAX INTEGER { + modAcquisition(0), + modBpsk63percent(1), + modQpsk63percentSingle(2), + modTransient1(3), + modQpsk87percentSingle(4), + modTransient2(5), + mod16qam63percentSingleA(6), + modTransient3(7), + mod16qam87percentSingle(8), + modTransient4(9), + mod64qam75percentSingle(10), + modTransient5(11), + mod64qam92percentSingle(12), + modTransient6(13), + mod256qam81percentSingle(14), + mod16qam63percentSingleB(15), + mod16qam63percentDual(16), + modTransient7(17), + mod16qam87percentDual(18), + modTransient8(19), + mod64qam75percentDual(20), + modTransient9(21), + mod64qam92percentDual(22), + modTransient10(23), + mod256qam81percentDual(24) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The lowest modulation mode at which Second Data Service + Ethernet traffic will be bridged over the wireless link" + ::= { management 21 } + + -- PhyControl group attribute definitions + -- + linkSymmetry OBJECT-TYPE + SYNTAX INTEGER { + symmetryAdaptive(0), + symmetry2to1(1), + symmetry1to1(2), + symmetry1to2(3), + symmetry3to1(4), + symmetry1to3(5), + symmetry5to1(6), + symmetry1to5(7) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Provides configuration options for sharing the available + wireless capacity between the transmit and receive + directions. Fixed link symmetry is defined by a ratio of + the burst duration for the transmit direction to the + burst duration for the receive direction. Permitted + settings are 5:1, 3:1, 2:1, 1:1, 1:2, 1:3, 1:5. The 1:1 + option provides fixed symmetric operation. The adaptive + option selects transmit and receive burst durations + automatically in response to the offered Ethernet traffic + in each link direction. This attribute is valid only for + a unit configured as a TDD Master" + ::= { phyControl 1 } + + userConfiguredMaxModulationMode OBJECT-TYPE + SYNTAX INTEGER { + modBpsk63percent(0), + modQpsk63percent(1), + modQpsk87percent(2), + mod16qam63percent(3), + mod16qam87percent(4), + mod64qam75percent(5), + mod64qam92percent(6), + mod256qam81percent(7) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The maximum receive modulation mode controls the MAX + mode used for adaptive modulation. NOTE: This attribute + is automatically disabled when the installation agent is + armed. To disarm the installation agent use the + installation wizard" + ::= { phyControl 2 } + + linkModeOptimization OBJECT-TYPE + SYNTAX INTEGER { + iPTraffic(0), + tDMTraffic(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Optimizes the wireless link behavior for the type of + traffic to be carried. In 'IP Traffic' mode, the wireless + link will minimize transmission errors by automatically + adapting the modulation mode. In 'TDM Traffic' mode, the + wireless link will minimize transmission latency and + preserve throughput by maintaining a higher modulation + mode in the presence of a limited number of errors. The + 'TDM Traffic' mode is recommended for E1/T1 applications + and connectionless protocols." + ::= { phyControl 3 } + + txColorCode OBJECT-TYPE + SYNTAX INTEGER { + a(0), + b(1), + c(2), + d(3), + e(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Transmit Color Code. This attribute need only be + considered when the unit is installed in a network of PTP + units and where some of the units are operating on the + same frequency. In this case, the value would normally be + derived by a network planner. In all other cases, it is + recommended that this attribute is left at the default + value. NOTE: For the link to operate, the value of this + parameter must in all cases match the value of the Rx + Color Code parameter at the far end of the link." + ::= { phyControl 4 } + + rxColorCode OBJECT-TYPE + SYNTAX INTEGER { + a(0), + b(1), + c(2), + d(3), + e(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Receive Color Code. This attribute need only be + considered when the unit is installed in a network of PTP + units and where some of the units are operating on the + same frequency. In this case, the value would normally be + derived by a network planner. In all other cases, it is + recommended that this attribute is left at the default + value. NOTE: For the link to operate, the value of this + parameter must in all cases match the value of the Tx + Color Code parameter at the far end of the link." + ::= { phyControl 5 } + + remoteMaximumTransmitPower OBJECT-TYPE + SYNTAX INTEGER (-15..30) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum transmit power the remote wireless unit is + permitted to use when establishing and maintaining the + wireless link" + ::= { phyControl 6 } + + -- PhyStatus group attribute definitions + -- + linkLoss OBJECT-TYPE + SYNTAX INTEGER (-500..500) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The wireless link loss expressed in tenths of a dB" + ::= { phyStatus 1 } + + receivePower OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Receive power expressed in tenths of a dBm" + ::= { phyStatus 2 } + + vectorError OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The vector error measurement compares the received + signal's IQ modulation characteristics to an ideal signal + to determine the composite error vector magnitude. The + value represented by this attribute is the average vector + error over the previous second expressed in tenths of a + dB" + ::= { phyStatus 3 } + + transmitPower OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Transmit power expressed in tenths of a dBm" + ::= { phyStatus 4 } + + receiveChannel OBJECT-TYPE + SYNTAX INTEGER (0..63) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current active receive channel" + ::= { phyStatus 5 } + + transmitChannel OBJECT-TYPE + SYNTAX INTEGER (0..63) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current active transmit channel" + ::= { phyStatus 6 } + + receiveFreqMHz OBJECT-TYPE + SYNTAX INTEGER (0..6050) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current receive frequency expressed in integer MHz" + ::= { phyStatus 7 } + + transmitFreqMHz OBJECT-TYPE + SYNTAX INTEGER (0..6050) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current transmit frequency expressed in integer MHz" + ::= { phyStatus 8 } + + signalStrengthRatio OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Signal strength ratio (Vertical / Horizontal) : the + number of dB larger the Vertical antenna input is than + the Horizontal antenna input expressed in tenths of a dB" + ::= { phyStatus 9 } + + receiveFreqKHz OBJECT-TYPE + SYNTAX INTEGER (0..6050000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current receive frequency expressed as KHz" + ::= { phyStatus 10 } + + transmitFreqKHz OBJECT-TYPE + SYNTAX INTEGER (0..6050000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current transmit frequency expressed as KHz" + ::= { phyStatus 11 } + + rawReceivePower OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Raw receive power expressed in tenths of a dBm" + ::= { phyStatus 12 } + + range OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Distance between the two peer wireless units expressed + in tenths of a kilometer" + ::= { phyStatus 13 } + + receiveModulationMode OBJECT-TYPE + SYNTAX INTEGER { + modAcquisition(0), + modBpsk63percent(1), + modQpsk63percentSingle(2), + modTransient1(3), + modQpsk87percentSingle(4), + modTransient2(5), + mod16qam63percentSingleA(6), + modTransient3(7), + mod16qam87percentSingle(8), + modTransient4(9), + mod64qam75percentSingle(10), + modTransient5(11), + mod64qam92percentSingle(12), + modTransient6(13), + mod256qam81percentSingle(14), + mod16qam63percentSingleB(15), + mod16qam63percentDual(16), + modTransient7(17), + mod16qam87percentDual(18), + modTransient8(19), + mod64qam75percentDual(20), + modTransient9(21), + mod64qam92percentDual(22), + modTransient10(23), + mod256qam81percentDual(24) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current active receive modulation mode" + ::= { phyStatus 14 } + + transmitModulationMode OBJECT-TYPE + SYNTAX INTEGER { + modAcquisition(0), + modBpsk63percent(1), + modQpsk63percentSingle(2), + modTransient1(3), + modQpsk87percentSingle(4), + modTransient2(5), + mod16qam63percentSingleA(6), + modTransient3(7), + mod16qam87percentSingle(8), + modTransient4(9), + mod64qam75percentSingle(10), + modTransient5(11), + mod64qam92percentSingle(12), + modTransient6(13), + mod256qam81percentSingle(14), + mod16qam63percentSingleB(15), + mod16qam63percentDual(16), + modTransient7(17), + mod16qam87percentDual(18), + modTransient8(19), + mod64qam75percentDual(20), + modTransient9(21), + mod64qam92percentDual(22), + modTransient10(23), + mod256qam81percentDual(24) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current active transmit modulation mode" + ::= { phyStatus 15 } + + searchState OBJECT-TYPE + SYNTAX INTEGER { + registering(0), + searching(1), + acquiring(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Search status of the wireless modem. 'Registering' means + that the modem has locked to an OFDM signal, and the + wireless link is up. 'Searching' means that no wireless + signal has been detected. 'Acquiring' means that a + wireless signal has been detected, but the modem has not + locked to an OFDM signal." + ::= { phyStatus 16 } + + -- Alarms group attribute definitions + -- + unitOutOfCalibration OBJECT-TYPE + SYNTAX INTEGER { + calibrated(0), + partialCalibration(1), + invalidCalibration(2), + bandwidthvariantunsupportedPAsShutdown(3), + outOfCalibrationPAsShutdown(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unit is out of calibration" + ::= { alarms 1 } + + incompatibleRegulatoryBands OBJECT-TYPE + SYNTAX INTEGER { + regOK(0), + regIncompatibleLicenseKeys(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The master and slave units have incompatible regulatory + bands. NB: Both units must have compatible license keys" + ::= { alarms 4 } + + noWirelessChannelAvailable OBJECT-TYPE + SYNTAX INTEGER { + ok(0), + noWirelessChannelAvailable(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Spectrum Management was unable to locate a suitable + wireless channel to operate on" + ::= { alarms 5 } + + wirelessLinkDisabledWarning OBJECT-TYPE + SYNTAX INTEGER { + ok(0), + disabledBySNMPifAdminStatus(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The SNMP ifAdminStatus of the wireless interface has + disabled wireless traffic" + ::= { alarms 6 } + + mainPSUPortDisabledWarning OBJECT-TYPE + SYNTAX INTEGER { + ok(0), + disabledBySNMPifAdminStatus(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The SNMP ifAdminStatus of the interface has disabled + Ethernet traffic" + ::= { alarms 7 } + + sFPError OBJECT-TYPE + SYNTAX INTEGER { + ok(0), + installedSFPNotLicensed(1), + fiberLinkNotEstablishedButLOSNotDetected(2), + fiberLinkNotEstablishedAndLOSDetected(3), + installedSFPNotSupported(4), + sFPInitializationFailed(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "If the SFP link is not OK, there are five possible + causes: Either a SFP has been installed but the license + key does not include SFP fiber support, a fiber link + could not be established even though no LOS was detected + (i.e. an optical carrier was detected, which could be due + to a broken TX fiber, or because the link is disabled at + the fiber link partner), a fiber link could not be + established and LOS is detected (i.e. no optical carrier + is detected), the installed SFP is not supported or the + installed SFP failed to initialize correctly. NB: a + change of status may generate an SNMP trap and/or SMTP + email alert" + ::= { alarms 8 } + + mainPSUPortConfigurationMismatch OBJECT-TYPE + SYNTAX INTEGER { + noError(0), + mismatchDetected(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The detection of Ethernet fragments (runt packets) when + the link is in full duplex is an indication of an + auto-negotiation or forced configuration mismatch" + ::= { alarms 9 } + + incompatibleMasterAndSlave OBJECT-TYPE + SYNTAX INTEGER { + ok(0), + incompatibleProductVariants(1), + differentSoftwareVersionsRunning(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A non-zero value indicates that the master and slave + ends of a link are different hardware products, or have + different software versions. NB: It is very unusual to + detect this, because incompatible units will normally + fail to establish a wireless link. However, some + combinations may establish a partial wireless link and + detect this situation. NB: A non-zero value may generate + an SNMP trap and/or SMTP email alert" + ::= { alarms 10 } + + tDDSynchronizationStatus OBJECT-TYPE + SYNTAX INTEGER { + locked(0), + holdover(1), + holdoverNoGPSSyncIn(2), + notSynchronized(3), + notSynchronizedNoGPSSyncIn(4), + pTPSYNCNotConnected(5), + initialising(6), + clusterTimingMaster(7), + acquiringLock(8), + inactive(9) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An alarm value (displayed in red) indicates that one of + the following conditions has not been met (i) An external + timing system is connected or internal timing has been + configured. (ii) The timing system is providing a useable + reference. (iii) The ODU is locked to this reference." + ::= { alarms 11 } + + auxPortDisabledWarning OBJECT-TYPE + SYNTAX INTEGER { + ok(0), + disabledBySNMPifAdminStatus(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The SNMP ifAdminStatus of the interface has disabled + Ethernet traffic" + ::= { alarms 12 } + + tDDSynchronizationAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok(0), + synchronizationLost(1), + referenceSignalLost(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Not Synchronized indicates failure of the external + timing system for a period greater than the holdover + timer. TDD frame timing will have drifted, and this link + may cause interference with other links in a synchronized + network. Timing System Failure is an early warning, + indicating that 80% of the holdover period has expired." + ::= { alarms 13 } + + linkModeOptimizationMismatch OBJECT-TYPE + SYNTAX INTEGER { + ok(0), + linkModeOptimizationMismatch(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The remote node of this link has been configured with a + different link mode optimization" + ::= { alarms 14 } + + auxPortConfigurationMismatch OBJECT-TYPE + SYNTAX INTEGER { + noError(0), + mismatchDetected(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The detection of Ethernet fragments (runt packets) when + the link is in full duplex is an indication of an + auto-negotiation or forced configuration mismatch. This + alarm is only raised if an Out-of-Band Management Mode + has been configured." + ::= { alarms 15 } + + secureModeAlarm OBJECT-TYPE + SYNTAX INTEGER { + secureModeIsActive(0), + secureModeIsNotConfigured(1), + secureModeIsConfiguredButNotActive(2), + secureModeIsNotSupported(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The secure mode (e.g. FIPS, UC-APL) state of the unit. + The secure mode is not configured(1) state indicates that + the unit is capable of secure mode operation, and one or + more of the following security materials has not been + configured: Key Of Keys, Private Key, Public Certificate, + DRNG Entropy Status, Wireless Encryption Key. The secure + mode mode is configured but not active(2) state indicates + that the unit is capable of secure mode operation, and + the security material has been configured, but the + configuration of interfaces is not consistent with secure + mode operation. The secure mode is not supported(3) state + indicates that the unit is not capable of secure mode + operation. The secure mode capability requires + appropriate hardware compatibility, license key and + software image." + ::= { alarms 16 } + + dataBridgingStatusAlarm OBJECT-TYPE + SYNTAX INTEGER { + bridgingEnabled(0), + bridgingDisabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ethernet Data traffic bridging is disabled because the + wireless link is not operating at the configured Lowest + Data Modulation Mode" + ::= { alarms 17 } + + sFPPortDisabledWarning OBJECT-TYPE + SYNTAX INTEGER { + ok(0), + disabledBySNMPifAdminStatus(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The SNMP ifAdminStatus of the interface has disabled + Ethernet traffic" + ::= { alarms 18 } + + sFPPortConfigurationMismatch OBJECT-TYPE + SYNTAX INTEGER { + noError(0), + mismatchDetected(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The detection of Ethernet fragments (runt packets) when + the link is in full duplex is an indication of an + auto-negotiation or forced configuration mismatch. This + alarm is only raised if an Out-of-Band Management Mode + has been configured." + ::= { alarms 19 } + + maxLinkRangeExceeded OBJECT-TYPE + SYNTAX INTEGER { + maxLinkRangeOK(0), + maxLinkRangeExceeded(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The measured link range is greater than the maximum + allowed by the license key. The link will operate at a + reduced capacity while this condition applies. This alarm + is only raised if the license specifies a maximum link + range and the trial license is not active." + ::= { alarms 20 } + + nIDULanPortDisabledWarning OBJECT-TYPE + SYNTAX INTEGER { + ok(0), + disabledBySNMPifAdminStatus(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The SNMP ifAdminStatus of the interface has disabled + Ethernet traffic" + ::= { alarms 21 } + + nIDULanPortConfigurationMismatch OBJECT-TYPE + SYNTAX INTEGER { + noError(0), + mismatchDetected(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The detection of Ethernet fragments (runt packets) when + the link is in full duplex is an indication of an + auto-negotiation or forced configuration mismatch." + ::= { alarms 22 } + + portAllocationMismatch OBJECT-TYPE + SYNTAX INTEGER { + portAllocationOK(0), + mismatchinSecondDataService(1), + mismatchinOutofBandRemoteManagementService(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The local and remote ODUs have different services + configured." + ::= { alarms 23 } + + secondDataBridgingStatusAlarm OBJECT-TYPE + SYNTAX INTEGER { + bridgingEnabled(0), + bridgingDisabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bridging of Ethernet traffic from Second Data Service + has been disabled because the wireless link is not + operating at the configured Lowest Second Data Modulation + Mode" + ::= { alarms 24 } + + transparentClockSourcePortAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok(0), + invalidTransparentClockSourcePort(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Transparent Clock will not function properly because + SFP, the selected clock source port is not FIBER" + ::= { alarms 25 } + + -- Smtp group attribute definitions + -- + sMTPEmailAlert OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Simple Mail Transfer Protocol is used to send equipment + alerts via email to a specified email address" + ::= { smtp 1 } + + sMTPServerPortNumber OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Port number of the SMTP server" + ::= { smtp 3 } + + sMTPSourceEmailAddress OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..63)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The 'from' email address used when constructing the + automatically generated e-mail message" + ::= { smtp 4 } + + sMTPDestinationEmailAddress OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..63)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The 'to' email address used when constructing the + automatically generated e-mail message" + ::= { smtp 5 } + + sMTPEnabledMessages OBJECT-TYPE + SYNTAX BITS { + nIDULanPortUpDown(0), + sFPPortUpDown(1), + auxPortUpDown(2), + mainPSUPortUpDown(3), + enabledDiagnosticAlarms(4), + dFSImpulseInterference(5), + channelChange(6), + wirelessLinkUpDown(7) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This controls which SMTP messages the unit will send" + ::= { smtp 6 } + + sMTPServerInternetAddressType OBJECT-TYPE + SYNTAX INTEGER { + unknown(0), + ipv4(1), + ipv6(2), + ipv4z(3), + ipv6z(4), + unknown6(5), + unknown7(6), + unknown8(7), + unknown9(8), + unknown10(9), + unknown11(10), + unknown12(11), + unknown13(12), + unknown14(13), + unknown15(14), + unknown16(15), + dns(16) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of Internet address specified by the associated + sMTPServerInternetAddress." + ::= { smtp 7 } + + sMTPServerInternetAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Internet address of the SMTP server" + ::= { smtp 8 } + + -- SnmpControl group attribute definitions + -- + sNMPPortNumber OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP port number used to access the SNMP MIB (i.e. + Gets and Sets) (default = 161). NB: A system reboot is + required to activate changes to this attribute" + ::= { snmpControl 1 } + + sNMPCommunityString OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..63)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The SNMP community string. NB: A system reboot is + required to activate changes to this attribute" + ::= { snmpControl 2 } + + sNMPTrapTableNumber OBJECT-TYPE + SYNTAX INTEGER (2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of entries in the sNMPTrapTable." + ::= { snmpControl 3 } + + sNMPTrapVersion OBJECT-TYPE + SYNTAX INTEGER { + v1(0), + v2c(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The SNMP protocol version to use for SNMP Traps. NB: A + system reboot is required to activate changes to this + attribute" + ::= { snmpControl 5 } + + sNMPEnabledTraps OBJECT-TYPE + SYNTAX BITS { + auxPortUpDown(0), + mainPSUPortUpDown(1), + authenticationFailure(2), + enabledDiagnosticAlarms(3), + dFSImpulseInterference(4), + channelChange(5), + wirelessLinkUpDown(6), + coldStart(7), + nIDULanPortUpDown(14), + sFPPortUpDown(15) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This controls which SNMP Traps the unit will send" + ::= { snmpControl 6 } + + enabledDiagnosticAlarms OBJECT-TYPE + SYNTAX BITS { + portState(0), + incompatibleMasterAndSlave(1), + incompatibleRegulatoryBands(2), + maximumLinkRangeExceeded(3), + unitOutOfCalibration(4), + installArmState(5), + installStatus(6), + regulatoryBand(7), + syslogLocalWrapped(8), + syslogLocalNearlyFull(9), + syslogDisabledWarning(10), + linkModeOptimizationMismatch(11), + tDDSynchronizationAlarm(12), + wirelessLinkDisabledWarning(13), + sNTPSynchronizationFailed(14), + noWirelessChannelAvailable(15), + tDMAlarms(18), + capacityVariantMismatch(19), + remainingFullCapacityTrialTime(20), + dataBridgingStatus(21), + unknown18(22), + syslogClientDisabledWarning(23) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls which individual diagnostic alarms are enabled. + The unit may be configured to generate SNMP traps and/or + SMTP email alerts for these enabled alarms by selecting + 'Enabled Diagnostic Alarms' on the 'SNMP Enabled Traps' + and/or 'SMTP Enabled Messages' attributes" + ::= { snmpControl 7 } + + sNMPSendAllTrapsAtStartup OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether cleared traps are reported at start-up + as well as raised traps. Only enabled traps will be + reported. NB: Traps corresponding to transient events + (i.e. not associated with an alarm or status value) are + only sent when required and not at start-up." + ::= { snmpControl 8 } + + -- SNMPTrapTable group attribute definitions + -- + sNMPTrapTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..2) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "SNMP trap value, used to index the SNMPTrapTable." + ::= { sNMPTrapTableEntry 1 } + + sNMPTrapPortNumber OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Destination port for SNMP Traps (default=162). NB: A + system reboot is required to activate changes to this + attribute." + ::= { sNMPTrapTableEntry 3 } + + sNMPTrapInternetAddressType OBJECT-TYPE + SYNTAX INTEGER { + unknown(0), + ipv4(1), + ipv6(2), + ipv4z(3), + ipv6z(4), + unknown6(5), + unknown7(6), + unknown8(7), + unknown9(8), + unknown10(9), + unknown11(10), + unknown12(11), + unknown13(12), + unknown14(13), + unknown15(14), + unknown16(15), + dns(16) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of Internet address specified by the associated + sNMPTrapInternetAddress." + ::= { sNMPTrapTableEntry 4 } + + sNMPTrapInternetAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Internet address to which all SNMP Traps are sent." + ::= { sNMPTrapTableEntry 5 } + + sNMPTrapReceiverEnabled OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A value of 0 disables the sending of SNMP trap to + corresponding receiver. A value of 1 enables the sending + of SNMP trap to corresponding receiver." + ::= { sNMPTrapTableEntry 6 } + + -- Sntp group attribute definitions + -- + sNTPState OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "SNTP control state" + ::= { sntp 1 } + + sNTPPollInterval OBJECT-TYPE + SYNTAX INTEGER (60..43200) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The SNTP server polling interval" + ::= { sntp 4 } + + sNTPSync OBJECT-TYPE + SYNTAX INTEGER { + noSync(0), + inSync(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "If SNTP Sync fails then check the server settings in the + Remote Management page, or disable SNTP" + ::= { sntp 5 } + + sNTPLastSync OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Last SNTP sync time" + ::= { sntp 6 } + + systemClock OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "System clock presented as local time" + ::= { sntp 7 } + + timeZone OBJECT-TYPE + SYNTAX INTEGER { + gmtMinus1200(0), + gmtMinus1130(1), + gmtMinus1100(2), + gmtMinus1030(3), + gmtMinus1000(4), + gmtMinus0930(5), + gmtMinus0900(6), + gmtMinus0830(7), + gmtMinus0800(8), + gmtMinus0730(9), + gmtMinus0700(10), + gmtMinus0630(11), + gmtMinus0600(12), + gmtMinus0530(13), + gmtMinus0500(14), + gmtMinus0430(15), + gmtMinus0400(16), + gmtMinus0330(17), + gmtMinus0300(18), + gmtMinus0230(19), + gmtMinus0200(20), + gmtMinus0130(21), + gmtMinus0100(22), + gmtMinus0030(23), + gmtZero(24), + gmtPlus0030(25), + gmtPlus0100(26), + gmtPlus0130(27), + gmtPlus0200(28), + gmtPlus0230(29), + gmtPlus0300(30), + gmtPlus0330(31), + gmtPlus0400(32), + gmtPlus0430(33), + gmtPlus0500(34), + gmtPlus0530(35), + gmtPlus0600(36), + gmtPlus0630(37), + gmtPlus0700(38), + gmtPlus0730(39), + gmtPlus0800(40), + gmtPlus0830(41), + gmtPlus0900(42), + gmtPlus0930(43), + gmtPlus1000(44), + gmtPlus1030(45), + gmtPlus1100(46), + gmtPlus1130(47), + gmtPlus1200(48), + gmtPlus1230(49), + gmtPlus1300(50) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time zone offsets from Greenwich Mean Time (GMT)" + ::= { sntp 8 } + + daylightSaving OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Daylight Saving Time" + ::= { sntp 9 } + + sNTPPrimaryServer OBJECT-TYPE + SYNTAX INTEGER { + server1(0), + server2(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies the primary SNTP server, determining the order + in which the servers are tried." + ::= { sntp 10 } + + sNTPPrimaryServerDeadTime OBJECT-TYPE + SYNTAX INTEGER (0..86400) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time (in seconds) to wait before retrying communications + with an unresponsive primary SNTP server. Setting the + value to 0 disables the timer." + ::= { sntp 11 } + + sNTPServerRetries OBJECT-TYPE + SYNTAX INTEGER (0..10) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of times the PTP will retry after an SNTP server + fails to respond." + ::= { sntp 12 } + + sNTPServerTimeout OBJECT-TYPE + SYNTAX INTEGER (1..15) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time (in seconds) the PTP will wait for a response from + an SNTP server." + ::= { sntp 13 } + + sNTPServerTableNumber OBJECT-TYPE + SYNTAX INTEGER (2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of entries in the SNTPServerTable." + ::= { sntp 14 } + + -- SNTPServerTable group attribute definitions + -- + sNTPServerTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..2) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Index range for the SNTPServerTable." + ::= { sNTPServerTableEntry 1 } + + sNTPServerPortNumber OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP port number of the SNTP server. Defaults to port + 123." + ::= { sNTPServerTableEntry 3 } + + sNTPServerStatus OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status message reflecting the result of communications + with the SNTP server when last polled" + ::= { sNTPServerTableEntry 4 } + + sNTPServerInternetAddressType OBJECT-TYPE + SYNTAX INTEGER { + unknown(0), + ipv4(1), + ipv6(2), + ipv4z(3), + ipv6z(4), + unknown6(5), + unknown7(6), + unknown8(7), + unknown9(8), + unknown10(9), + unknown11(10), + unknown12(11), + unknown13(12), + unknown14(13), + unknown15(14), + unknown16(15), + dns(16) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of Internet address specified by the associated + sNTPServerInternetAddress." + ::= { sNTPServerTableEntry 5 } + + sNTPServerInternetAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Internet address of a valid SNTP server" + ::= { sNTPServerTableEntry 6 } + + -- Reset group attribute definitions + -- + systemReset OBJECT-TYPE + SYNTAX INTEGER { + running(0), + consoleReboot(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Setting this attribute to '1' will cause a system + reboot. NB: a system reboot will apply any pending new + settings held in memory" + ::= { reset 1 } + + -- Versions group attribute definitions + -- + softwareVersion OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..63)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current software version" + ::= { versions 1 } + + hardwareVersion OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..63)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Hardware platform version" + ::= { versions 2 } + + secondarySoftwareVersion OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..63)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Secondary software version, used when the primary + software image is invalid or erased" + ::= { versions 3 } + + bootVersion OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..63)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Boot code software version" + ::= { versions 4 } + + -- PubStats group attribute definitions + -- + receiveDataRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average data rate over the last one second interval + (kbps)" + ::= { pubStats 1 } + + transmitDataRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average data rate over the last one second interval + (kbps)" + ::= { pubStats 2 } + + aggregateDataRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average data rate over the last one second interval + (kbps)" + ::= { pubStats 3 } + + wirelessLinkAvailability OBJECT-TYPE + SYNTAX INTEGER (0..1000000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Link availability calculated since the last reset of the + system counters, as a percentage multiplied by 10000 to + give four decimal places of precision" + ::= { pubStats 4 } + + wirelessLinkStatus OBJECT-TYPE + SYNTAX INTEGER { + up(0), + registering(1), + searching(2), + acquiring(3), + radarCAC(4), + initialising(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current status of the wireless link" + ::= { pubStats 5 } + + byteErrorRatio OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Reciprocal of the byte error ratio calculated since the + last reset of the system counters" + ::= { pubStats 6 } + + receiveModulationModeDetail OBJECT-TYPE + SYNTAX INTEGER { + runningAtMaximumReceiveMode(0), + runningAtUserConfiguredMaxModulationMode(1), + restrictedBecauseInstallationIsArmed(2), + restrictedBecauseOfByteErrorsOnTheWirelessLink(3), + restrictedBecauseTheLinkParametersAreUpdating(4), + restrictedBecauseChannelChangeIsInProgress(5), + restrictedDueToTheLowEthernetLinkSpeed(6), + runningAtMaximumReceiveModeForChannelBandwidth(7), + limitedByTheWirelessConditions(8), + restrictedBecauseFullCapabilityTrialLicenseExpired(9) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The reason for the current receive modulation mode" + ::= { pubStats 7 } + + dataBridgingAvailability OBJECT-TYPE + SYNTAX INTEGER (0..1000000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Link availability bridging Ethernet Data traffic + calculated since the last reset of the system counters, + as a percentage multiplied by 10000 to give four decimal + places of precision" + ::= { pubStats 8 } + + -- Encryption group attribute definitions + -- + encryptionAlgorithm OBJECT-TYPE + SYNTAX INTEGER { + none(0), + aESRijndael(1), + aES192bitRijndael(2), + aES256bitRijndael(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Encryption Algorithm used by the wireless link. NB: + A system reboot is required to activate changes to this + attribute. NB: The same Encryption Algorithm must be + configured at BOTH ends of the link for it to function + correctly" + ::= { encryption 1 } + + -- TDDControl group attribute definitions + -- + tDDSynchronizationMode OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TDD Synchronization Mode selection" + ::= { tDDControl 1 } + + -- AAAControl group attribute definitions + -- + userTableNumber OBJECT-TYPE + SYNTAX INTEGER (1..10) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of entries in the userTable" + ::= { aAAControl 1 } + + -- UserTable group attribute definitions + -- + userTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..10) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "used to index values in the userTable." + ::= { userTableEntry 1 } + + userName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..67)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "User name which must be entered, along with the + appropriate password, in order to gain access to the + system." + ::= { userTableEntry 2 } + + userRole OBJECT-TYPE + SYNTAX INTEGER { + readOnly(0), + systemAdministrator(1), + securityOfficer(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Role of the selected user. A Security Officer has access + to and can modify all settings. A System Administrator + has access to and can modify all non-security settings. A + Read Only user can view settings, but cannot make any + changes." + ::= { userTableEntry 3 } + + userEnabled OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Enable / Disable the selected user" + ::= { userTableEntry 4 } + + userPassword OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..67)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "User password, which must be entered in order to gain + access to the system." + ::= { userTableEntry 5 } + + -- SyslogControl group attribute definitions + -- + syslogClient OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Enable or disable the syslog client" + ::= { syslogControl 1 } + + syslogState OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The syslog service has been enabled or disabled" + ::= { syslogControl 2 } + + -- RouterProtocols group attribute definitions + -- + microwaveAdaptiveBandwidth OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Enable support of Microwave Adaptive Bandwidth Protocol. + MAB is disabled if link symmetry is configured as + Adaptive" + ::= { routerProtocols 1 } + + mABNominalModulationMode OBJECT-TYPE + SYNTAX INTEGER { + modAcquisition(0), + modBpsk63percent(1), + modQpsk63percentSingle(2), + modTransient1(3), + modQpsk87percentSingle(4), + modTransient2(5), + mod16qam63percentSingleA(6), + modTransient3(7), + mod16qam87percentSingle(8), + modTransient4(9), + mod64qam75percentSingle(10), + modTransient5(11), + mod64qam92percentSingle(12), + modTransient6(13), + mod256qam81percentSingle(14), + mod16qam63percentSingleB(15), + mod16qam63percentDual(16), + modTransient7(17), + mod16qam87percentDual(18), + modTransient8(19), + mod64qam75percentDual(20), + modTransient9(21), + mod64qam92percentDual(22), + modTransient10(23), + mod256qam81percentDual(24) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Nominal modulation mode is the desired modulation + mode. MAB VSM packets are generated when the current + modulation mode falls below the nominal modulation." + ::= { routerProtocols 2 } + + mABTransmissionInterval OBJECT-TYPE + SYNTAX INTEGER { + transmissionInterval1s(0), + transmissionInterval10s(1), + transmissionInterval60s(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum interval (in seconds) between successive MAB + vendor specific messages (VSM). These VSM are sent when + the current transmit capacity falls below the configured + MAB Nominal Modulation Mode." + ::= { routerProtocols 3 } + + mABHoldoffPeriod OBJECT-TYPE + SYNTAX INTEGER (10..60) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The period (in seconds) over which transmit capacity is + averaged over to determine when the wireless link has + degraded" + ::= { routerProtocols 4 } + + mABMaintenanceLevel OBJECT-TYPE + SYNTAX INTEGER (0..7) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maintenance Levels (0-7) determines the destination MAC + address of MAB vendor specific messages." + ::= { routerProtocols 5 } + + useVLANForMABProtocol OBJECT-TYPE + SYNTAX INTEGER { + noVLANTagging(0), + iEEE8021QTaggedCTagType8100(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This controls whether MAB vendor specific messages (VSM) + packets use VLAN tags or not." + ::= { routerProtocols 6 } + + mABProtocolVID OBJECT-TYPE + SYNTAX INTEGER (0..4094) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This VLAN VID (0-4094) will be included in MAB vendor + specific messages (VSM) packets." + ::= { routerProtocols 7 } + + mABProtocolVLANPriority OBJECT-TYPE + SYNTAX INTEGER (0..7) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This VLAN Priority (0-7) will be included in MAB vendor + specific messages (VSM) packets." + ::= { routerProtocols 8 } + + mABState OBJECT-TYPE + SYNTAX INTEGER { + normal(0), + degraded(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current state of MAB Protocol. A state of 'Normal' on a + green background indicates that a PTP link is operating + at nominal capacity" + ::= { routerProtocols 9 } + + mABNominalTransmitCapacity OBJECT-TYPE + SYNTAX INTEGER (0..1000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The nominal Tx capacity used in MAB Vendor Specific + Messages for the selected nominal modulation mode " + ::= { routerProtocols 10 } + + mABCurrentTransmitCapacity OBJECT-TYPE + SYNTAX INTEGER (0..1000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current Tx capacity of the wireless link used in the + last MAB Vendor Specific Message transmitted." + ::= { routerProtocols 11 } + + -- CableDiagnostics group attribute definitions + -- + cableDiagnosticsPorts OBJECT-TYPE + SYNTAX BITS { + auxPort(6), + mainPSUPort(7) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Select ports on which Cable Diagnostics must be + executed" + ::= { cableDiagnostics 1 } + + cableDiagnosticsControl OBJECT-TYPE + SYNTAX INTEGER { + startTest(0), + testInProgress(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Set this attribute to 'Test in Progress' to start a + Cable Diagnostics test" + ::= { cableDiagnostics 2 } + + cableDiagnosticsWarning OBJECT-TYPE + SYNTAX INTEGER { + idle(0), + testInProgress(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Normal Ethernet operation is disrupted when a Cable + Diagnostics test is in progress" + ::= { cableDiagnostics 3 } + + cableDiagnosticsResultTableNumber OBJECT-TYPE + SYNTAX INTEGER (1..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of rows in the Cable Diagnostics Result Table." + ::= { cableDiagnostics 4 } + + -- CableDiagnosticsResultTable group attribute definitions + -- + cableDiagnosticsResultTableIndex OBJECT-TYPE + SYNTAX INTEGER (1..2) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Cable Diagnostics Port value used to index into the + result table." + ::= { cableDiagnosticsResultTableEntry 1 } + + cableDiagnosticsResultsDateTime OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Date and Time when a Cable Diagnostics test was last + executed" + ::= { cableDiagnosticsResultTableEntry 2 } + + cableDiagPair1Results OBJECT-TYPE + SYNTAX INTEGER { + ok(0), + unknown(1), + inProgress(2), + notTested(3), + openCircuit(4), + shortCircuit(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The result of the most recent execution of Cable + Diagnostics on cable pair 1. According to the T658B + wiring scheme, pair 1 is pins 4 & 5 on the RJ45 socket on + the ODU. Open Circuit is reported when the impedance is + greater than 330 ohms. Short Circuit is reported when the + impedance is less than 33 ohms. Unknown is reported when + a continuous signal is received from the link partner for + 125 ms, preventing start of the test." + ::= { cableDiagnosticsResultTableEntry 3 } + + cableDiagPair1Distance OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The distance in meters from the ODU to the fault + detected on the cable pair during the most recent + execution of Cable Diagnostics. Faults in cables longer + than 160 meters (525 feet) may not be detected. The error + margin is +/-2 meters (6.5 feet)." + ::= { cableDiagnosticsResultTableEntry 4 } + + cableDiagPair2Results OBJECT-TYPE + SYNTAX INTEGER { + ok(0), + unknown(1), + inProgress(2), + notTested(3), + openCircuit(4), + shortCircuit(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The result of the most recent execution of Cable + Diagnostics on cable pair 2. According to the T658B + wiring scheme, pair 2 is pins 1 & 2 on the RJ45 socket on + the ODU. Open Circuit is reported when the impedance is + greater than 330 ohms. Short Circuit is reported when the + impedance is less than 33 ohms. Unknown is reported when + a continuous signal is received from the link partner for + 125 ms, preventing start of the test." + ::= { cableDiagnosticsResultTableEntry 5 } + + cableDiagPair2Distance OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The distance in meters from the ODU to the fault + detected on the cable pair during the most recent + execution of Cable Diagnostics. Faults in cables longer + than 160 meters (525 feet) may not be detected. The error + margin is +/-2 meters (6.5 feet)." + ::= { cableDiagnosticsResultTableEntry 6 } + + cableDiagPair3Results OBJECT-TYPE + SYNTAX INTEGER { + ok(0), + unknown(1), + inProgress(2), + notTested(3), + openCircuit(4), + shortCircuit(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The result of the most recent execution of Cable + Diagnostics on cable pair 3. According to the T658B + wiring scheme, pair 3 is pins 3 & 6 on the RJ45 socket on + the ODU. Open Circuit is reported when the impedance is + greater than 330 ohms. Short Circuit is reported when the + impedance is less than 33 ohms. Unknown is reported when + a continuous signal is received from the link partner for + 125 ms, preventing start of the test." + ::= { cableDiagnosticsResultTableEntry 7 } + + cableDiagPair3Distance OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The distance in meters from the ODU to the fault + detected on the cable pair during the most recent + execution of Cable Diagnostics. Faults in cables longer + than 160 meters (525 feet) may not be detected. The error + margin is +/-2 meters (6.5 feet)." + ::= { cableDiagnosticsResultTableEntry 8 } + + cableDiagPair4Results OBJECT-TYPE + SYNTAX INTEGER { + ok(0), + unknown(1), + inProgress(2), + notTested(3), + openCircuit(4), + shortCircuit(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The result of the most recent execution of Cable + Diagnostics on cable pair 4. According to the T658B + wiring scheme, pair 4 is pins 7 & 8 on the RJ45 socket on + the ODU. Open Circuit is reported when the impedance is + greater than 330 ohms. Short Circuit is reported when the + impedance is less than 33 ohms. Unknown is reported when + a continuous signal is received from the link partner for + 125 ms, preventing start of the test." + ::= { cableDiagnosticsResultTableEntry 9 } + + cableDiagPair4Distance OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The distance in meters from the ODU to the fault + detected on the cable pair during the most recent + execution of Cable Diagnostics. Faults in cables longer + than 160 meters (525 feet) may not be detected. The error + margin is +/-2 meters (6.5 feet)." + ::= { cableDiagnosticsResultTableEntry 10 } + + -- Supplementary group attribute definitions + -- + longitude OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..19)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The longitude of the unit, measured in decimal degrees. + This object is set by the SNMP manager and has no + internal function." + ::= { supplementary 1 } + + latitude OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..19)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The latitude of the unit, measured in decimal degrees. + This object is set by the SNMP manager and has no + internal function." + ::= { supplementary 2 } + + altitude OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The altitude of the unit, measured in meters. This + object is set by the SNMP manager and has no internal + function." + ::= { supplementary 3 } + + -- Enterprise NOTIFICATION definitions + -- + + channelChangeTrap NOTIFICATION-TYPE + OBJECTS { receiveChannel } + STATUS current + DESCRIPTION "The PTP radio has changed wireless channel. + This has been caused by either + i) mandatory radar avoidance, + a DFS impulsive interference event will also be + detected, + or + ii) Dynamic Spectrum Optimization, (DSO) + DSO improves link performance by selecting the + most appropriate transmit and receive channels + with the lowest level of interference." + ::= { ptpTrapPrefix 1 } + + dfsImpulsiveInterferenceTrap NOTIFICATION-TYPE + OBJECTS { receiveChannel } + STATUS current + DESCRIPTION "DFS impulsive interference detected event" + ::= { ptpTrapPrefix 2 } + + mainPSUPortStatusTrap NOTIFICATION-TYPE + OBJECTS { mainPSUPortStatus } + STATUS current + DESCRIPTION + "Current status of the Main PSU Ethernet link. NB: a + change of state may generate an SNMP trap and/or SMTP + email alert" + ::= { ptpTrapPrefix 3 } + + mainPSUPortDisabledWarningTrap NOTIFICATION-TYPE + OBJECTS { mainPSUPortDisabledWarning } + STATUS current + DESCRIPTION + "The SNMP ifAdminStatus of the interface has disabled + Ethernet traffic" + ::= { ptpTrapPrefix 4 } + + mainPSUPortConfigurationMismatchTrap NOTIFICATION-TYPE + OBJECTS { mainPSUPortConfigurationMismatch } + STATUS current + DESCRIPTION + "The detection of Ethernet fragments (runt packets) when + the link is in full duplex is an indication of an + auto-negotiation or forced configuration mismatch" + ::= { ptpTrapPrefix 5 } + + auxPortStatusTrap NOTIFICATION-TYPE + OBJECTS { auxPortStatus } + STATUS current + DESCRIPTION + "Current status of the Aux Ethernet link. NB: a change of + state may generate an SNMP trap and/or SMTP email alert" + ::= { ptpTrapPrefix 6 } + + auxPortDisabledWarningTrap NOTIFICATION-TYPE + OBJECTS { auxPortDisabledWarning } + STATUS current + DESCRIPTION + "The SNMP ifAdminStatus of the interface has disabled + Ethernet traffic" + ::= { ptpTrapPrefix 7 } + + regulatoryBandTrap NOTIFICATION-TYPE + OBJECTS { regulatoryBand } + STATUS current + DESCRIPTION + "The Regulatory Band prohibits the wireless unit from + operating outside the regulated limits. An invalid + Regulatory Band may be caused by a missing or incorrect + License Key, a corrupt MAC Address or an attempt to + configure a Regulatory Band not allowed by the License + Key. NB: a change of state may generate an SNMP trap + and/or SMTP email alert." + ::= { ptpTrapPrefix 8 } + + installStatusTrap NOTIFICATION-TYPE + OBJECTS { installStatus } + STATUS current + DESCRIPTION + "A non-zero value indicates that signalling was received + with the wrong MAC address or a mismatched link name. NB: + It is very unusual to detect this, because units with + mis-configured Target MAC Address will normally fail to + establish a wireless link. However, rare circumstances + may establish a partial wireless link and detect this + situation. NB: A non-zero value on start-up, or a change + of value during operation, may generate an SNMP trap + and/or SMTP email alert" + ::= { ptpTrapPrefix 9 } + + installArmStateTrap NOTIFICATION-TYPE + OBJECTS { installArmState } + STATUS current + DESCRIPTION + "Indicates if the unit is being installed. NB: a change + of state may generate an SNMP trap and/or SMTP email + alert" + ::= { ptpTrapPrefix 10 } + + unitOutOfCalibrationTrap NOTIFICATION-TYPE + OBJECTS { unitOutOfCalibration } + STATUS current + DESCRIPTION + "The unit is out of calibration" + ::= { ptpTrapPrefix 11 } + + auxPortPowerOverEthernetOutputStatusTrap NOTIFICATION-TYPE + OBJECTS { auxPortPowerOverEthernetOutputStatus } + STATUS current + DESCRIPTION + "Current status of the Power Over Ethernet (PoE) output + of the Aux port" + ::= { ptpTrapPrefix 12 } + + incompatibleRegulatoryBandsTrap NOTIFICATION-TYPE + OBJECTS { incompatibleRegulatoryBands } + STATUS current + DESCRIPTION + "The master and slave units have incompatible regulatory + bands. NB: Both units must have compatible license keys" + ::= { ptpTrapPrefix 14 } + + noWirelessChannelAvailableTrap NOTIFICATION-TYPE + OBJECTS { noWirelessChannelAvailable } + STATUS current + DESCRIPTION + "Spectrum Management was unable to locate a suitable + wireless channel to operate on" + ::= { ptpTrapPrefix 15 } + + wirelessLinkDisabledWarningTrap NOTIFICATION-TYPE + OBJECTS { wirelessLinkDisabledWarning } + STATUS current + DESCRIPTION + "The SNMP ifAdminStatus of the wireless interface has + disabled wireless traffic" + ::= { ptpTrapPrefix 16 } + + auxPortConfigurationMismatchTrap NOTIFICATION-TYPE + OBJECTS { auxPortConfigurationMismatch } + STATUS current + DESCRIPTION + "The detection of Ethernet fragments (runt packets) when + the link is in full duplex is an indication of an + auto-negotiation or forced configuration mismatch. This + alarm is only raised if an Out-of-Band Management Mode + has been configured." + ::= { ptpTrapPrefix 17 } + + sFPErrorTrap NOTIFICATION-TYPE + OBJECTS { sFPError } + STATUS current + DESCRIPTION + "If the SFP link is not OK, there are five possible + causes: Either a SFP has been installed but the license + key does not include SFP fiber support, a fiber link + could not be established even though no LOS was detected + (i.e. an optical carrier was detected, which could be due + to a broken TX fiber, or because the link is disabled at + the fiber link partner), a fiber link could not be + established and LOS is detected (i.e. no optical carrier + is detected), the installed SFP is not supported or the + installed SFP failed to initialize correctly. NB: a + change of status may generate an SNMP trap and/or SMTP + email alert" + ::= { ptpTrapPrefix 18 } + + sFPPortStatusTrap NOTIFICATION-TYPE + OBJECTS { sFPPortStatus } + STATUS current + DESCRIPTION + "Current status of the SFP Ethernet link. NB: a change of + state may generate an SNMP trap and/or SMTP email alert" + ::= { ptpTrapPrefix 19 } + + incompatibleMasterAndSlaveTrap NOTIFICATION-TYPE + OBJECTS { incompatibleMasterAndSlave } + STATUS current + DESCRIPTION + "A non-zero value indicates that the master and slave + ends of a link are different hardware products, or have + different software versions. NB: It is very unusual to + detect this, because incompatible units will normally + fail to establish a wireless link. However, some + combinations may establish a partial wireless link and + detect this situation. NB: A non-zero value may generate + an SNMP trap and/or SMTP email alert" + ::= { ptpTrapPrefix 20 } + + sNTPSyncTrap NOTIFICATION-TYPE + OBJECTS { sNTPSync } + STATUS current + DESCRIPTION + "If SNTP Sync fails then check the server settings in the + Remote Management page, or disable SNTP" + ::= { ptpTrapPrefix 21 } + + tDDSynchronizationAlarmTrap NOTIFICATION-TYPE + OBJECTS { tDDSynchronizationAlarm } + STATUS current + DESCRIPTION + "Not Synchronized indicates failure of the external + timing system for a period greater than the holdover + timer. TDD frame timing will have drifted, and this link + may cause interference with other links in a synchronized + network. Timing System Failure is an early warning, + indicating that 80% of the holdover period has expired." + ::= { ptpTrapPrefix 22 } + + sFPPortDisabledWarningTrap NOTIFICATION-TYPE + OBJECTS { sFPPortDisabledWarning } + STATUS current + DESCRIPTION + "The SNMP ifAdminStatus of the interface has disabled + Ethernet traffic" + ::= { ptpTrapPrefix 23 } + + sFPPortConfigurationMismatchTrap NOTIFICATION-TYPE + OBJECTS { sFPPortConfigurationMismatch } + STATUS current + DESCRIPTION + "The detection of Ethernet fragments (runt packets) when + the link is in full duplex is an indication of an + auto-negotiation or forced configuration mismatch. This + alarm is only raised if an Out-of-Band Management Mode + has been configured." + ::= { ptpTrapPrefix 24 } + + linkModeOptimizationMismatchTrap NOTIFICATION-TYPE + OBJECTS { linkModeOptimizationMismatch } + STATUS current + DESCRIPTION + "The remote node of this link has been configured with a + different link mode optimization" + ::= { ptpTrapPrefix 25 } + + tDMInterfaceStatusTrap NOTIFICATION-TYPE + OBJECTS { tDMInterfaceStatus } + STATUS current + DESCRIPTION + "@Current status of the connection to the TDM Box. A + state of 'Up' on a green background indicates that the + TDM Box is connected OK. When connecting a TDM Box only + the Main Ethernet port should be used" + ::= { ptpTrapPrefix 26 } + + tDMChannelStatusTrap NOTIFICATION-TYPE + OBJECTS { tDMChannelStatus } + STATUS current + DESCRIPTION + "Current status of the TDM channels. A value of 0 + indicates that a TDM channel is established" + ::= { ptpTrapPrefix 27 } + + tDMChannelLoopbackTrap NOTIFICATION-TYPE + OBJECTS { tDMChannelLoopback } + STATUS current + DESCRIPTION + "The loopback status of TDM channels. This is intended + for installation testing and should be set to 'None' for + normal operation. The wire connections to a unit can be + tested by applying a 'Copper' loopback to the local unit. + The wireless connection to the remote unit can be tested + by applying a 'Wireless' loopback to the remote unit with + no loopback on the local unit. NB: a change of state may + generate an SNMP trap and/or SMTP email alert" + ::= { ptpTrapPrefix 28 } + + nIDULanPortStatusTrap NOTIFICATION-TYPE + OBJECTS { nIDULanPortStatus } + STATUS current + DESCRIPTION + "Current status of the NIDU LAN Ethernet link. NB: a + change of state may generate an SNMP trap and/or SMTP + email alert" + ::= { ptpTrapPrefix 29 } + + syslogStateTrap NOTIFICATION-TYPE + OBJECTS { syslogState } + STATUS current + DESCRIPTION + "The syslog service has been enabled or disabled" + ::= { ptpTrapPrefix 30 } + + syslogLocalNearlyFullTrap NOTIFICATION-TYPE + STATUS current + DESCRIPTION "The syslog local log is nearly full (90%)" + ::= { ptpTrapPrefix 31 } + + syslogLocalWrappedTrap NOTIFICATION-TYPE + STATUS current + DESCRIPTION "The syslog local log has wrapped" + ::= { ptpTrapPrefix 32 } + + syslogClientTrap NOTIFICATION-TYPE + OBJECTS { syslogClient } + STATUS current + DESCRIPTION + "Enable or disable the syslog client" + ::= { ptpTrapPrefix 33 } + + secureModeAlarmTrap NOTIFICATION-TYPE + OBJECTS { secureModeAlarm } + STATUS current + DESCRIPTION + "The secure mode (e.g. FIPS, UC-APL) state of the unit. + The secure mode is not configured(1) state indicates that + the unit is capable of secure mode operation, and one or + more of the following security materials has not been + configured: Key Of Keys, Private Key, Public Certificate, + DRNG Entropy Status, Wireless Encryption Key. The secure + mode mode is configured but not active(2) state indicates + that the unit is capable of secure mode operation, and + the security material has been configured, but the + configuration of interfaces is not consistent with secure + mode operation. The secure mode is not supported(3) state + indicates that the unit is not capable of secure mode + operation. The secure mode capability requires + appropriate hardware compatibility, license key and + software image." + ::= { ptpTrapPrefix 34 } + + dataBridgingStatusAlarmTrap NOTIFICATION-TYPE + OBJECTS { dataBridgingStatusAlarm } + STATUS current + DESCRIPTION + "Ethernet Data traffic bridging is disabled because the + wireless link is not operating at the configured Lowest + Data Modulation Mode" + ::= { ptpTrapPrefix 35 } + + licenseRemainingTrialPeriodAlarmTrap NOTIFICATION-TYPE + OBJECTS { licenseRemainingTrialPeriodAlarm } + STATUS current + DESCRIPTION + "If the full capability trial license period is about to + expire then purchase a license upgrade from your + reseller." + ::= { ptpTrapPrefix 36 } + + capacityVariantMismatchTrap NOTIFICATION-TYPE + OBJECTS { capacityVariantMismatch } + STATUS current + DESCRIPTION + "The remote node of this link has a lower link capacity. + Operating with a reduced effective link capacity." + ::= { ptpTrapPrefix 37 } + + maxLinkRangeExceededTrap NOTIFICATION-TYPE + OBJECTS { maxLinkRangeExceeded } + STATUS current + DESCRIPTION + "The measured link range is greater than the maximum + allowed by the license key. The link will operate at a + reduced capacity while this condition applies. This alarm + is only raised if the license specifies a maximum link + range and the trial license is not active." + ::= { ptpTrapPrefix 38 } + + tDMConfigurationMismatchTrap NOTIFICATION-TYPE + OBJECTS { tDMConfigurationMismatch } + STATUS current + DESCRIPTION + "Current status of the configuration of the TDM Box. A + state of 'Ok' on a green background indicates that the + TDM Box configuration is matched OK with the remote end." + ::= { ptpTrapPrefix 39 } + + nIDULanPortDisabledWarningTrap NOTIFICATION-TYPE + OBJECTS { nIDULanPortDisabledWarning } + STATUS current + DESCRIPTION + "The SNMP ifAdminStatus of the interface has disabled + Ethernet traffic" + ::= { ptpTrapPrefix 40 } + + nIDULanPortConfigurationMismatchTrap NOTIFICATION-TYPE + OBJECTS { nIDULanPortConfigurationMismatch } + STATUS current + DESCRIPTION + "The detection of Ethernet fragments (runt packets) when + the link is in full duplex is an indication of an + auto-negotiation or forced configuration mismatch." + ::= { ptpTrapPrefix 41 } + + secondDataBridgingStatusAlarmTrap NOTIFICATION-TYPE + OBJECTS { secondDataBridgingStatusAlarm } + STATUS current + DESCRIPTION + "Bridging of Ethernet traffic from Second Data Service + has been disabled because the wireless link is not + operating at the configured Lowest Second Data Modulation + Mode" + ::= { ptpTrapPrefix 42 } + + transparentClockSourcePortAlarmTrap NOTIFICATION-TYPE + OBJECTS { transparentClockSourcePortAlarm } + STATUS current + DESCRIPTION + "Transparent Clock will not function properly because + SFP, the selected clock source port is not FIBER" + ::= { ptpTrapPrefix 43 } + + portAllocationMismatchTrap NOTIFICATION-TYPE + OBJECTS { portAllocationMismatch } + STATUS current + DESCRIPTION + "The local and remote ODUs have different services + configured." + ::= { ptpTrapPrefix 44 } + + END -- cgit v1.2.3