From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/carel/CAREL-RITTAL-LCP-3311-MIB | 801 +++++++++ MIBS/carel/CAREL-ug40cdz-MIB | 1546 ++++++++++++++++ MIBS/carel/KELVIN-pCOWeb-Chiller-MIB | 3278 ++++++++++++++++++++++++++++++++++ MIBS/carel/SCS-ks-MIB | 248 +++ 4 files changed, 5873 insertions(+) create mode 100644 MIBS/carel/CAREL-RITTAL-LCP-3311-MIB create mode 100644 MIBS/carel/CAREL-ug40cdz-MIB create mode 100644 MIBS/carel/KELVIN-pCOWeb-Chiller-MIB create mode 100644 MIBS/carel/SCS-ks-MIB (limited to 'MIBS/carel') diff --git a/MIBS/carel/CAREL-RITTAL-LCP-3311-MIB b/MIBS/carel/CAREL-RITTAL-LCP-3311-MIB new file mode 100644 index 0000000..54f30b4 --- /dev/null +++ b/MIBS/carel/CAREL-RITTAL-LCP-3311-MIB @@ -0,0 +1,801 @@ +-- ***************************************************************** +-- CAREL-RITTAL-LCP-3311-MIB +-- MIB for rittal 3311 lcp chillers using a carel pcoweb card (SK 3311.320) +-- +-- June, 2021 Gregory Bers, Limburg, Belgium +-- +-- System OID found under .1.3.6.1.2.1.1.2.0 +-- +-- Documentation: https://github.com/epiecs/carel-pco-mibs +-- +-- PCO settings +-- System OID: 1.3.6.1.4.1.9839.2606.1 +-- Enterprise OID: 9839.2606 +-- ***************************************************************** + +CAREL-RITTAL-LCP-3311-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, enterprises, OBJECT-TYPE, Integer32 + FROM SNMPv2-SMI + OBJECT-GROUP + FROM SNMPv2-CONF + TEXTUAL-CONVENTION + FROM SNMPv2-TC + ; + +carel MODULE-IDENTITY + LAST-UPDATED "202106290000Z" + ORGANIZATION "Epiecs" + CONTACT-INFO + "EPIECS + epiecs.be + + Email: gregorybers@epiecs.be" + DESCRIPTION + "Custom MIB for Rittal LCP 3311 chillers connected to a pco web card" + + REVISION + "202106290000Z" + + DESCRIPTION + "First draft containing the values outlined in the 3311.320 docs + https://www.rittal.com/imf/none/3_4342/3311320_Instructions_spec__EN" + + ::= { enterprises 9839 } + +-- tree under 9839 + rittal OBJECT IDENTIFIER ::= { carel 2606 } + rittalLCP3311 OBJECT IDENTIFIER ::= { rittal 2 } + sensors OBJECT IDENTIFIER ::= { rittalLCP3311 1 } + digital OBJECT IDENTIFIER ::= { sensors 1 } + analog OBJECT IDENTIFIER ::= { sensors 2 } + integer OBJECT IDENTIFIER ::= { sensors 3 } + +-- +-- object groups +-- + +-- integerSensors OBJECT-GROUP +-- OBJECTS { fanSpeedPercent, fanSpeedRpm } +-- STATUS current +-- DESCRIPTION +-- "A collection of all sensors providing integer values" +-- ::= { integer 1 } + +-- +-- conversions +-- + +DivBy10 ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d-1" + STATUS current + DESCRIPTION "Fixed point, one decimal" + SYNTAX Integer32 + +-- +-- digital objects +-- + + -- .1.3.6.1.4.1.9839.2606.2.1.1.2 +compressorOverloadAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Compressor overload alarm + ok (0), + alarm (1)" + ::= { digital 2 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.3 +highPressureAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High pressure alarm + ok (0), + alarm (1)" + ::= { digital 3 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.8 +remoteOnOff OBJECT-TYPE + SYNTAX INTEGER { + off (0), + on (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Remote On/Off + off (0), + on (1)" + ::= { digital 8 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.11 +inverterAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Inverter alarm + ok (0), + alarm (1)" + ::= { digital 11 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.12 +driveAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Power+ drive off-line alarm + ok (0), + alarm (1)" + ::= { digital 12 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.17 +inverterOnOff OBJECT-TYPE + SYNTAX INTEGER { + off (0), + on (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Inverter On/Off + off (0), + on (1)" + ::= { digital 17 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.23 +generalAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "General alarm + alarm (0), + ok (1)" + ::= { digital 23 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.29 +resetAllAlarms OBJECT-TYPE + SYNTAX INTEGER { + no (0), + yes (1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reset all alarms + no (0), + yes (1)" + ::= { digital 29 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.30 +compressorEnvelopeAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Compressor forced off working out envelope + ok (0), + alarm (1)" + ::= { digital 30 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.31 +compressorStartupFailureAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Compressor startup failure alarm, reached max retries + ok (0), + alarm (1)" + ::= { digital 31 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.33 +maxDischargeTemperatureAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum discharge temperature has been reached + ok (0), + alarm (1)" + ::= { digital 33 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.35 +compressorDeltaPressureAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Delta pressure too big to startup compressor + ok (0), + alarm (1)" + ::= { digital 35 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.36 +oilReturnAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Oil return alarm for when the compressor is running. Lubrication issue. + ok (0), + alarm (1)" + ::= { digital 36 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.38 +outputTemperatureTopProbeAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Top output temperature probe broken + ok (0), + alarm (1)" + ::= { digital 38 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.39 +outputTemperatureMidProbeAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Mid output temperature probe broken + ok (0), + alarm (1)" + ::= { digital 39 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.40 +outputTemperatureBottomProbeAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bottom output temperature probe broken + ok (0), + alarm (1)" + ::= { digital 40 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.42 +inputTemperatureTopProbeAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Top input temperature probe broken + ok (0), + alarm (1)" + ::= { digital 42 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.43 +inputTemperatureMidProbeAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Mid input temperature probe broken + ok (0), + alarm (1)" + ::= { digital 43 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.44 +inputTemperatureBottomProbeAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bottom input temperature probe broken + ok (0), + alarm (1)" + ::= { digital 44 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.45 +compressorDischargeTemperatureProbeAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Compressor discharge temperature probe broken + ok (0), + alarm (1)" + ::= { digital 45 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.46 +compressorSuctionTemperatureProbeAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Compressor suction temperature probe broken + ok (0), + alarm (1)" + ::= { digital 46 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.47 +compressorDischargePressureProbeAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Compressor discharge pressure probe broken + ok (0), + alarm (1)" + ::= { digital 47 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.48 +compressorSuctionPressureProbeAlarm OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + alarm (1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Compressor suction pressure probe broken + ok (0), + alarm (1)" + ::= { digital 48 } + + -- .1.3.6.1.4.1.9839.2606.2.1.1.100 +reboot OBJECT-TYPE + SYNTAX INTEGER { + no (0), + yes (1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reboot the system + no (0), + yes (1)" + ::= { digital 100 } + +-- +-- integer objects +-- + + -- .1.3.6.1.4.1.9839.2606.2.1.3.1 +compressorRotorSpeedHz OBJECT-TYPE + SYNTAX INTEGER (0..9999) + UNITS "Hz" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Compressor rotor speed in Hz" + ::= { integer 1 } + + -- .1.3.6.1.4.1.9839.2606.2.1.3.2 +driverPowerStatus OBJECT-TYPE + SYNTAX INTEGER { + stop (1), + run (2), + alarm (3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Driver power status + stop (1), + run (2), + alarm (3)" + ::= { integer 2 } + + -- .1.3.6.1.4.1.9839.2606.2.1.3.3 +currentErrorCode OBJECT-TYPE + SYNTAX INTEGER { + OK (0), + ALA02 (2), + ALA03 (3), + ALA04 (4), + ALA05 (5), + ALA06 (6), + ALA07 (7), + ALA08 (8), + ALA09 (9), + ALA10 (10), + ALA11 (11), + ALA12 (12), + ALB01 (13), + ALB02 (14), + ALB03 (15), + ALC01 (16), + ALC03 (17), + ALC04 (18), + ALC05 (19), + ALC06 (20), + ALF01 (21), + ALD02 (22), + ALD03 (23), + ALD04 (24), + ALD05 (25), + ALD06 (26), + ALD07 (27), + ALD08 (28), + ALD09 (29), + ALL01 (30), + ALL02 (31), + ALL99 (32), + ALW04 (33) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current error code" + ::= { integer 3 } + + -- .1.3.6.1.4.1.9839.2606.2.1.3.4 +driverTemperature OBJECT-TYPE + SYNTAX DivBy10 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Driver Power+ Temperature" + ::= { integer 4 } + + -- .1.3.6.1.4.1.9839.2606.2.1.3.5 +dcBusVoltage OBJECT-TYPE + SYNTAX DivBy10 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Power+ DC Voltage" + ::= { integer 5 } + + -- .1.3.6.1.4.1.9839.2606.2.1.3.6 +motorVoltage OBJECT-TYPE + SYNTAX DivBy10 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Motor Voltage" + ::= { integer 6 } + + -- .1.3.6.1.4.1.9839.2606.2.1.3.7 +powerRequest OBJECT-TYPE + SYNTAX DivBy10 + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Request of power for inverter after envelop" + ::= { integer 7 } + + -- .1.3.6.1.4.1.9839.2606.2.1.3.13 +unitOnOff OBJECT-TYPE + SYNTAX INTEGER { + off (0), + on (1), + energy-save (2), + auto (3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Unit on/off state + off (0), + on (1), + energy-save (2), + auto (3) + " + ::= { integer 13 } + + -- .1.3.6.1.4.1.9839.2606.2.1.3.14 +envelopeZone OBJECT-TYPE + SYNTAX INTEGER { + ok (0), + maximum-compression-ratio (1), + maximum-discharge-power (2), + current-limit (3), + maximum-suction-power(4), + minimum-compression-ratio (5), + minimum-delta-power (6), + minimum-discharge-power(7), + minimum-suction-power (8) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "envelope zone + ok (0), + maximum compression ratio (1), + maximum discharge power (2), + current limit (3), + maximum suction power(4), + minimum compression ratio (5), + minimum delta power (6), + minimum discharge power(7), + minimum suction power (8) + " + ::= { integer 14 } + + -- .1.3.6.1.4.1.9839.2606.2.1.3.16 +coolingCapacity OBJECT-TYPE + SYNTAX INTEGER (0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual EVD valve cooling capacity" + ::= { integer 16 } + + -- .1.3.6.1.4.1.9839.2606.2.1.3.17 +evdValveSteps OBJECT-TYPE + SYNTAX INTEGER (0..540) + UNITS "steps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "EVD valve steps position" + ::= { integer 17 } + + -- .1.3.6.1.4.1.9839.2606.2.1.3.28 +fanSpeedPercent OBJECT-TYPE + SYNTAX INTEGER (0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The fan speed percentage" + ::= { integer 28 } + + -- .1.3.6.1.4.1.9839.2606.2.1.3.29 +fanSpeedRpm OBJECT-TYPE + SYNTAX INTEGER (0..3700) + UNITS "rpm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The fan speed rpm" + ::= { integer 29 } + + -- .1.3.6.1.4.1.9839.2606.2.1.3.30 +evdValveOpening OBJECT-TYPE + SYNTAX INTEGER (0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual EVD valve opening" + ::= { integer 30 } + +-- +-- analog objects +-- + + -- .1.3.6.1.4.1.9839.2606.2.1.2.2 +outputTemperatureTopSensor OBJECT-TYPE + SYNTAX DivBy10 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Top sensor output temperature in Celcius" + ::= { analog 2 } + + -- .1.3.6.1.4.1.9839.2606.2.1.2.3 +outputTemperatureMidSensor OBJECT-TYPE + SYNTAX DivBy10 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Mid sensor output temperature in Celcius" + ::= { analog 3 } + + -- .1.3.6.1.4.1.9839.2606.2.1.2.4 +outputTemperatureBottomSensor OBJECT-TYPE + SYNTAX DivBy10 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bottom sensor output temperature in Celcius" + ::= { analog 4 } + + -- .1.3.6.1.4.1.9839.2606.2.1.2.6 +inputTemperatureTopSensor OBJECT-TYPE + SYNTAX DivBy10 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Top sensor input temperature in Celcius" + ::= { analog 6 } + + -- .1.3.6.1.4.1.9839.2606.2.1.2.7 +inputTemperatureMidSensor OBJECT-TYPE + SYNTAX DivBy10 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Mid sensor input temperature in Celcius" + ::= { analog 7 } + + -- .1.3.6.1.4.1.9839.2606.2.1.2.8 +inputTemperatureBottomSensor OBJECT-TYPE + SYNTAX DivBy10 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bottom sensor input temperature in Celcius" + ::= { analog 8 } + + -- .1.3.6.1.4.1.9839.2606.2.1.2.9 +compressorDischargeTemperature OBJECT-TYPE + SYNTAX DivBy10 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Compressor discharge temperature" + ::= { analog 9 } + + -- .1.3.6.1.4.1.9839.2606.2.1.2.10 +compressorSuctionTemperature OBJECT-TYPE + SYNTAX DivBy10 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Compressor suction temperature" + ::= { analog 10 } + + -- .1.3.6.1.4.1.9839.2606.2.1.2.11 +compressorDischargePressure OBJECT-TYPE + SYNTAX DivBy10 + UNITS "bar" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Compressor discharge pressure" + ::= { analog 11 } + + -- .1.3.6.1.4.1.9839.2606.2.1.2.12 +compressorSuctionPressure OBJECT-TYPE + SYNTAX DivBy10 + UNITS "bar" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Compressor suction pressure" + ::= { analog 12 } + + -- .1.3.6.1.4.1.9839.2606.2.1.2.13 +evaporatorTemperature OBJECT-TYPE + SYNTAX DivBy10 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Evaporator temperature from Low pressure conversion" + ::= { analog 13 } + + -- .1.3.6.1.4.1.9839.2606.2.1.2.14 +condensingTemperature OBJECT-TYPE + SYNTAX DivBy10 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Condensing temperature from High pressure conversion" + ::= { analog 14 } + + -- .1.3.6.1.4.1.9839.2606.2.1.2.21 +inputTemperatureAverage OBJECT-TYPE + SYNTAX DivBy10 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average input temperature in Celcius" + ::= { analog 21 } + + -- .1.3.6.1.4.1.9839.2606.2.1.2.22 +outputTemperatureAverage OBJECT-TYPE + SYNTAX DivBy10 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Average output temperature in Celcius" + ::= { analog 22 } + + -- .1.3.6.1.4.1.9839.2606.2.1.2.45 +compressorRotorSpeed OBJECT-TYPE + SYNTAX DivBy10 + UNITS "rps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Compressor rotor speed" + ::= { analog 45 } + + -- .1.3.6.1.4.1.9839.2606.2.1.2.46 +compressorMotorCurrent OBJECT-TYPE + SYNTAX DivBy10 + UNITS "A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Compressor motor current" + ::= { analog 46 } + + -- .1.3.6.1.4.1.9839.2606.2.1.2.48 +lcpSetpoint OBJECT-TYPE + SYNTAX DivBy10 + UNITS "C" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Main LCP setpoint" + ::= { analog 48 } + +END diff --git a/MIBS/carel/CAREL-ug40cdz-MIB b/MIBS/carel/CAREL-ug40cdz-MIB new file mode 100644 index 0000000..7f9e462 --- /dev/null +++ b/MIBS/carel/CAREL-ug40cdz-MIB @@ -0,0 +1,1546 @@ +-- +-- CAREL-ug40cdz.MIB +-- MIB generated by CAREL +-- Tuesday, 11 April 2006 +-- + + CAREL-ug40cdz-MIB DEFINITIONS ::= BEGIN + + IMPORTS + OBJECT-GROUP FROM SNMPv2-CONF + sysContact, sysName, + sysLocation FROM SNMPv2-MIB + enterprises, MODULE-IDENTITY, + OBJECT-TYPE, Integer32 FROM SNMPv2-SMI + DisplayString FROM RFC1213-MIB; + + ug40cdzMIB MODULE-IDENTITY + LAST-UPDATED "200604111645Z" -- April 11, 2006 at 16:45 GMT + ORGANIZATION "CAREL SpA" + CONTACT-INFO + " + Carel SpA + Via dell'Industria, 11 + 35020 Brugine (PD) Italy + Tel: +39 049 9716611 + E-mail: carel@carel.com + " + DESCRIPTION + "This is the MIB module for the UG40 Close Control Uniflair device." + REVISION "200604111645Z" -- April 11, 2006 at 16:45 GMT + DESCRIPTION + "This is the original version of the MIB" + ::= { instruments 1 } + +-- +-- Node definitions +-- + + -- 1.3.6.1.4.1.9839 + carel OBJECT IDENTIFIER ::= { enterprises 9839 } + + -- 1.3.6.1.4.1.9839.1 + systm OBJECT IDENTIFIER ::= { carel 1 } + + -- 1.3.6.1.4.1.9839.1.1 + agentRelease OBJECT-TYPE + SYNTAX Integer32 + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Release of the Agent." + ::= { systm 1 } + + -- 1.3.6.1.4.1.9839.1.2 + agentCode OBJECT-TYPE + SYNTAX Integer32 + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Code of the Agent. 1=WebGate" + ::= { systm 2 } + + -- 1.3.6.1.4.1.9839.2 + instruments OBJECT IDENTIFIER ::= { carel 2 } + + -- 1.3.6.1.4.1.9839.2.0 + webGateInfo OBJECT IDENTIFIER ::= { instruments 0 } + + -- 1.3.6.1.4.1.9839.2.0.1 + agentParameters OBJECT IDENTIFIER ::= { webGateInfo 1 } + + -- 1.3.6.1.4.1.9839.2.0.1.1 + netSize OBJECT-TYPE + SYNTAX Integer32 (1..16) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Network size. It corresponds to the number of units connected to the WebGate. " + ::= { agentParameters 1 } + + -- 1.3.6.1.4.1.9839.2.0.1.2 + baudRate OBJECT-TYPE + SYNTAX Integer32 (1200 | 2400 |4800 |9600 | 19200) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Baudrate of the Carel network. " + ::= { agentParameters 2 } + + -- 1.3.6.1.4.1.9839.2.0.2 + unitTypeGroup OBJECT IDENTIFIER ::= { webGateInfo 2 } + + -- 1.3.6.1.4.1.9839.2.0.2.1 + unit1-Type OBJECT-TYPE + SYNTAX DisplayString + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Type of the unit having serial address 1. " + ::= { unitTypeGroup 1 } + + -- ... You will have how many unitX-Type objects as the value of netSize is + + -- 1.3.6.1.4.1.9839.2.0.3 + unitCodeGroup OBJECT IDENTIFIER ::= { webGateInfo 3 } + + -- 1.3.6.1.4.1.9839.2.0.3.1 + unit1-Code OBJECT-TYPE + SYNTAX Integer32 + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Code of the unit having serial address 1. " + ::= { unitCodeGroup 1 } + + -- ... You will have how many unitX-Code objects as the value of netSize is + + -- 1.3.6.1.4.1.9839.2.0.4 + unitSoftwareReleaseGroup OBJECT IDENTIFIER ::= { webGateInfo 4 } + + -- 1.3.6.1.4.1.9839.2.0.3.1 + unit1-SoftwareRelease OBJECT-TYPE + SYNTAX Integer32 + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Software release of the unit having serial address 1. " + ::= { unitSoftwareReleaseGroup 1 } + + -- ... You will have how many unitX-SoftwareRelease objects as the value of netSize is + + -- 1.3.6.1.4.1.9839.2.0.5 + unitMinSoftwareReleaseGroup OBJECT IDENTIFIER ::= { webGateInfo 5 } + + -- 1.3.6.1.4.1.9839.2.0.5.1 + unit1-MinSoftwareRelease OBJECT-TYPE + SYNTAX Integer32 + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Minimum software release of the unit having serial address 1. " + ::= { unitMinSoftwareReleaseGroup 1 } + + -- ... You will have how many unitX-MinSoftwareRelease objects as the value of netSize is + + -- 1.3.6.1.4.1.9839.2.0.6 + unitMaxSoftwareReleaseGroup OBJECT IDENTIFIER ::= { webGateInfo 6 } + + -- 1.3.6.1.4.1.9839.2.0.6.1 + unit1-MaxSoftwareRelease OBJECT-TYPE + SYNTAX Integer32 + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Maximum software release of the unit having serial address 1. " + ::= { unitMaxSoftwareReleaseGroup 1 } + + -- ... You will have how many unitX-MaxSoftwareRelease objects as the value of netSize is + + -- 1.3.6.1.4.1.9839.2.0.7 + unitNoAnswerCounterGroup OBJECT IDENTIFIER ::= { webGateInfo 7 } + + -- 1.3.6.1.4.1.9839.2.0.7.1 + unit1-NoAnswerCounter OBJECT-TYPE + SYNTAX Integer32 + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "No answer counter of the unit having serial address 1. " + ::= { unitNoAnswerCounterGroup 1 } + + -- ... You will have how many unitX-NoAnswerCounter objects as the value of netSize is + + -- 1.3.6.1.4.1.9839.2.0.8 + unitErrorChecksumCounterGroup OBJECT IDENTIFIER ::= { webGateInfo 8 } + + -- 1.3.6.1.4.1.9839.2.0.8.1 + unit1-ErrorChecksumCounter OBJECT-TYPE + SYNTAX Integer32 + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Error checksum counter of the unit having serial address 1. " + ::= { unitErrorChecksumCounterGroup 1 } + + -- ... You will have how many unitX-ErrorChecksumCounter objects as the value of netSize is + + -- 1.3.6.1.4.1.9839.2.0.9 + unitTimeoutCounterGroup OBJECT IDENTIFIER ::= { webGateInfo 9 } + + -- 1.3.6.1.4.1.9839.2.0.9.1 + unit1-TimeoutCounter OBJECT-TYPE + SYNTAX Integer32 + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Timeout counter of the unit having serial address 1. " + ::= { unitTimeoutCounterGroup 1 } + + -- ... You will have how many unitX-TimeoutCounter objects as the value of netSize is + + -- 1.3.6.1.4.1.9839.2.1 + -- ug40cdzMIB OBJECT IDENTIFIER ::= { instruments 1 } + + -- 1.3.6.1.4.1.9839.2.1.1 + digitalObjects OBJECT IDENTIFIER ::= { ug40cdzMIB 1 } + + -- 1.3.6.1.4.1.9839.2.1.1.1 + systemOn OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "System On (Fan)" + ::= { digitalObjects 1 } + + -- 1.3.6.1.4.1.9839.2.1.1.2 + compressore1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Compressor 1" + ::= { digitalObjects 2 } + + -- 1.3.6.1.4.1.9839.2.1.1.3 + compressore2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Compressor 2" + ::= { digitalObjects 3 } + + -- 1.3.6.1.4.1.9839.2.1.1.4 + compressore3 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Compressor 3" + ::= { digitalObjects 4 } + + -- 1.3.6.1.4.1.9839.2.1.1.5 + compressore4 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Compressor 4" + ::= { digitalObjects 5 } + + -- 1.3.6.1.4.1.9839.2.1.1.6 + heating1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Heating 1" + ::= { digitalObjects 6 } + + -- 1.3.6.1.4.1.9839.2.1.1.7 + heating2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Heating 2" + ::= { digitalObjects 7 } + + -- 1.3.6.1.4.1.9839.2.1.1.9 + hotGasCoil OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Hot Gas Coil" + ::= { digitalObjects 9 } + + -- 1.3.6.1.4.1.9839.2.1.1.10 + dehumidification OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Dehumidification" + ::= { digitalObjects 10 } + + -- 1.3.6.1.4.1.9839.2.1.1.11 + humidification OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Humidification" + ::= { digitalObjects 11 } + + -- 1.3.6.1.4.1.9839.2.1.1.12 + emerg OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Main Power Loss" + ::= { digitalObjects 12 } + + -- 1.3.6.1.4.1.9839.2.1.1.20 + alarmAccess OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Tampering Alarm" + ::= { digitalObjects 20 } + + -- 1.3.6.1.4.1.9839.2.1.1.21 + alarmRoomHT OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Room High Temperature" + ::= { digitalObjects 21 } + + -- 1.3.6.1.4.1.9839.2.1.1.22 + alarmRoomLT OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Room Low Temperature" + ::= { digitalObjects 22 } + + -- 1.3.6.1.4.1.9839.2.1.1.23 + alarmRoomHH OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Room High Humidity" + ::= { digitalObjects 23 } + + -- 1.3.6.1.4.1.9839.2.1.1.24 + alarmRoomLH OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Room Low Humidity" + ::= { digitalObjects 24 } + + -- 1.3.6.1.4.1.9839.2.1.1.25 + alarmRoomEAP OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Room T+H Limits by External Sensors" + ::= { digitalObjects 25 } + + -- 1.3.6.1.4.1.9839.2.1.1.26 + alarmFilter OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Clogged Filter" + ::= { digitalObjects 26 } + + -- 1.3.6.1.4.1.9839.2.1.1.27 + alarmFlood OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Water Leakage Detected" + ::= { digitalObjects 27 } + + -- 1.3.6.1.4.1.9839.2.1.1.28 + alarmAirFlow OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Loss of Air Flow" + ::= { digitalObjects 28 } + + -- 1.3.6.1.4.1.9839.2.1.1.29 + alarmHeater OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Heater Overheating" + ::= { digitalObjects 29 } + + -- 1.3.6.1.4.1.9839.2.1.1.30 + alarmHP1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Circuit 1 High Pressure" + ::= { digitalObjects 30 } + + -- 1.3.6.1.4.1.9839.2.1.1.31 + alarmHP2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Circuit 1 High Pressure" + ::= { digitalObjects 31 } + + -- 1.3.6.1.4.1.9839.2.1.1.32 + alarmLP1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Circuit 1 Low Pressure" + ::= { digitalObjects 32 } + + -- 1.3.6.1.4.1.9839.2.1.1.33 + alarmLP2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Circuit 2 Low Pressure" + ::= { digitalObjects 33 } + + -- 1.3.6.1.4.1.9839.2.1.1.34 + alarmEXV1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Circuit 1 Electronic Valve Failure" + ::= { digitalObjects 34 } + + -- 1.3.6.1.4.1.9839.2.1.1.35 + alarmEXV2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Circuit 2 Electronic Valve Failure" + ::= { digitalObjects 35 } + + -- 1.3.6.1.4.1.9839.2.1.1.36 + alarmPSE OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Wrong Phase Sequence" + ::= { digitalObjects 36 } + + -- 1.3.6.1.4.1.9839.2.1.1.37 + alarmSmokeFire OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: SMOKE-FIRE DETECTED" + ::= { digitalObjects 37 } + + -- 1.3.6.1.4.1.9839.2.1.1.38 + alarmLAN OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Interrupted LAN Alarm" + ::= { digitalObjects 38 } + + -- 1.3.6.1.4.1.9839.2.1.1.39 + alarmHUHC OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Humidifier High Current" + ::= { digitalObjects 39 } + + -- 1.3.6.1.4.1.9839.2.1.1.40 + alarmHUPL OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Humidifier Power Loss" + ::= { digitalObjects 40 } + + -- 1.3.6.1.4.1.9839.2.1.1.41 + alarmHUWL OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Humidifier Water Loss" + ::= { digitalObjects 41 } + + -- 1.3.6.1.4.1.9839.2.1.1.42 + alarmCWDHT OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: CW Temperature too High for Dehumidification" + ::= { digitalObjects 42 } + + -- 1.3.6.1.4.1.9839.2.1.1.43 + alarmCWF OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: CW Valve Failure or Water Flow too Low" + ::= { digitalObjects 43 } + + -- 1.3.6.1.4.1.9839.2.1.1.44 + alarmCWFF OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Loss of Water Flow" + ::= { digitalObjects 44 } + + -- 1.3.6.1.4.1.9839.2.1.1.45 + alarmCWHT OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: High Chilled Water Temperature" + ::= { digitalObjects 45 } + + -- 1.3.6.1.4.1.9839.2.1.1.46 + alarmRTS OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Room Temp. Sensor Failed/Disconnected" + ::= { digitalObjects 46 } + + -- 1.3.6.1.4.1.9839.2.1.1.47 + alarmHWS OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Hot Water Temp. Sensor Failed/Disconnected" + ::= { digitalObjects 47 } + + -- 1.3.6.1.4.1.9839.2.1.1.48 + alarmCWS OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Chilled Water Temp. Sensor Failed/Disconnected" + ::= { digitalObjects 48 } + + -- 1.3.6.1.4.1.9839.2.1.1.49 + alarmOTS OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Outdoor Temperature Sensor Failed/Disconnected" + ::= { digitalObjects 49 } + + -- 1.3.6.1.4.1.9839.2.1.1.50 + alarmDTS OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Delivery Air Temp. Sensor Failed/Disconnected" + ::= { digitalObjects 50 } + + -- 1.3.6.1.4.1.9839.2.1.1.51 + alarmRHS OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Room Humidity Sensor Failed/Disconnected" + ::= { digitalObjects 51 } + + -- 1.3.6.1.4.1.9839.2.1.1.52 + alarmCWOTS OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm: Chilled Water Outlet T. Sensor Failed/Disconnected" + ::= { digitalObjects 52 } + + -- 1.3.6.1.4.1.9839.2.1.1.53 + alarmC1Hours OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "ServiceAlarm: Compressor 1 hour counter threshold" + ::= { digitalObjects 53 } + + -- 1.3.6.1.4.1.9839.2.1.1.54 + alarmC2Hours OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "ServiceAlarm: Compressor 2 hour counter threshold" + ::= { digitalObjects 54 } + + -- 1.3.6.1.4.1.9839.2.1.1.55 + alarmC3Hours OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "ServiceAlarm: Compressor 3 hour counter threshold" + ::= { digitalObjects 55 } + + -- 1.3.6.1.4.1.9839.2.1.1.56 + alarmC4Hours OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "ServiceAlarm: Compressor 4 hour counter threshold" + ::= { digitalObjects 56 } + + -- 1.3.6.1.4.1.9839.2.1.1.57 + alarmFilterHours OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "ServiceAlarm: Air Filter hour counter threshold" + ::= { digitalObjects 57 } + + -- 1.3.6.1.4.1.9839.2.1.1.58 + alarmHeat1Hours OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "ServiceAlarm: Heater 1 hour counter threshold" + ::= { digitalObjects 58 } + + -- 1.3.6.1.4.1.9839.2.1.1.59 + alarmHeat2Hours OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "ServiceAlarm: Heater 1 hour counter threshold" + ::= { digitalObjects 59 } + + -- 1.3.6.1.4.1.9839.2.1.1.60 + alarmHumHours OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "ServiceAlarm: Humidifier hour counter threshold" + ::= { digitalObjects 60 } + + -- 1.3.6.1.4.1.9839.2.1.1.61 + alarmUnitHours OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "ServiceAlarm: Unit hour counter threshold" + ::= { digitalObjects 61 } + + -- 1.3.6.1.4.1.9839.2.1.1.62 + alarmDI2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm by Digital Input 2" + ::= { digitalObjects 62 } + + -- 1.3.6.1.4.1.9839.2.1.1.63 + alarmDI4 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm by Digital Input 4" + ::= { digitalObjects 63 } + + -- 1.3.6.1.4.1.9839.2.1.1.64 + alarmDI6 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Alarm by Digital Input 6" + ::= { digitalObjects 64 } + + -- 1.3.6.1.4.1.9839.2.1.1.65 + alarmHum OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Humidifier General Alarm" + ::= { digitalObjects 65 } + + -- 1.3.6.1.4.1.9839.2.1.1.66 + alarmGeneral OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "General Alarm" + ::= { digitalObjects 66 } + + -- 1.3.6.1.4.1.9839.2.1.1.67 + alarm2ndLevel OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Standby Unit Switchover Alarm" + ::= { digitalObjects 67 } + + -- 1.3.6.1.4.1.9839.2.1.1.68 + alarmA OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Type A Alarm" + ::= { digitalObjects 68 } + + -- 1.3.6.1.4.1.9839.2.1.1.69 + alarmB OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Type B Alarm" + ::= { digitalObjects 69 } + + -- 1.3.6.1.4.1.9839.2.1.1.70 + alarmC OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Type C Alarm" + ::= { digitalObjects 70 } + + -- 1.3.6.1.4.1.9839.2.1.1.71 + selDXCW OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "DX/CW Switch on TC Units" + ::= { digitalObjects 71 } + + -- 1.3.6.1.4.1.9839.2.1.1.72 + selSW OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Summer/Winter Switchover" + ::= { digitalObjects 72 } + + -- 1.3.6.1.4.1.9839.2.1.1.75 + systemOnOff OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "System On-Off" + ::= { digitalObjects 75 } + + -- 1.3.6.1.4.1.9839.2.1.1.76 + resetAlarm OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Alarm Reset" + ::= { digitalObjects 76 } + + -- 1.3.6.1.4.1.9839.2.1.1.77 + resetHrsFilt OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Filter Run Hours Reset" + ::= { digitalObjects 77 } + + -- 1.3.6.1.4.1.9839.2.1.1.78 + resetHrC1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Compressor 1 Run Hours Reset" + ::= { digitalObjects 78 } + + -- 1.3.6.1.4.1.9839.2.1.1.79 + resetHrC2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Compressor 2 Run Hours Reset" + ::= { digitalObjects 79 } + + -- 1.3.6.1.4.1.9839.2.1.1.80 + resetHrC3 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Compressor 3 Run Hours Reset" + ::= { digitalObjects 80 } + + -- 1.3.6.1.4.1.9839.2.1.1.81 + resetHrC4 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Compressor 4 Run Hours Reset" + ::= { digitalObjects 81 } + + -- 1.3.6.1.4.1.9839.2.1.1.82 + resetStC1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Compressor 1 Starting Counter Reset " + ::= { digitalObjects 82 } + + -- 1.3.6.1.4.1.9839.2.1.1.83 + resetStC2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Compressor 2 Starting Counter Reset " + ::= { digitalObjects 83 } + + -- 1.3.6.1.4.1.9839.2.1.1.84 + resetStC3 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Compressor 3 Starting Counter Reset " + ::= { digitalObjects 84 } + + -- 1.3.6.1.4.1.9839.2.1.1.85 + resetStC4 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Compressor 4 Starting Counter Reset " + ::= { digitalObjects 85 } + + -- 1.3.6.1.4.1.9839.2.1.1.86 + resetHrH1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Heater 1 Run Hours Reset" + ::= { digitalObjects 86 } + + + -- 1.3.6.1.4.1.9839.2.1.1.87 + resetHrH2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Heater 2 Run Hours Reset" + ::= { digitalObjects 87 } + + -- 1.3.6.1.4.1.9839.2.1.1.88 + resetStH1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Heater 1 Starting Counter Reset" + ::= { digitalObjects 88 } + + -- 1.3.6.1.4.1.9839.2.1.1.89 + resetStH2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Heater 2 Starting Counter Reset" + ::= { digitalObjects 89 } + + -- 1.3.6.1.4.1.9839.2.1.1.90 + resetHrHU OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Humidifier Run Hours Reset" + ::= { digitalObjects 90 } + + -- 1.3.6.1.4.1.9839.2.1.1.91 + resetStHU OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Humidifier Starting Counter Reset" + ::= { digitalObjects 91 } + + -- 1.3.6.1.4.1.9839.2.1.1.92 + resetHrACU OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Unit Run Hours Reset" + ::= { digitalObjects 92 } + + -- 1.3.6.1.4.1.9839.2.1.1.95 + sleepmode OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Setback Mode (Sleep Mode)" + ::= { digitalObjects 95 } + + -- 1.3.6.1.4.1.9839.2.1.1.96 + smtest OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Sleep Mode Test" + ::= { digitalObjects 96 } + + -- 1.3.6.1.4.1.9839.2.1.1.97 + enablemeanT OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Local/Mean Usage of Values" + ::= { digitalObjects 97 } + + + -- 1.3.6.1.4.1.9839.2.1.2 + analogObjects OBJECT IDENTIFIER ::= { ug40cdzMIB 2 } + + -- 1.3.6.1.4.1.9839.2.1.2.1 + roomTemp OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Room Temperature" + ::= { analogObjects 1 } + + -- 1.3.6.1.4.1.9839.2.1.2.2 + outdoorTemp OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Ambient Temperature" + ::= { analogObjects 2 } + + -- 1.3.6.1.4.1.9839.2.1.2.3 + deliveryTemp OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Delivery Air Temperature" + ::= { analogObjects 3 } + + -- 1.3.6.1.4.1.9839.2.1.2.4 + cwTemp OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Chilled Water Temperature" + ::= { analogObjects 4 } + + -- 1.3.6.1.4.1.9839.2.1.2.5 + hwTemp OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Hot Water Temperature" + ::= { analogObjects 5 } + + -- 1.3.6.1.4.1.9839.2.1.2.6 + roomRH OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "rH%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Room Relative Humidity" + ::= { analogObjects 6 } + + -- 1.3.6.1.4.1.9839.2.1.2.7 + cwoTemp OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Chilled Water Outlet Temperature" + ::= { analogObjects 7 } + + -- 1.3.6.1.4.1.9839.2.1.2.8 + evapPress1 OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "bar" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Circuit 1 Evaporating Pressure" + ::= { analogObjects 8 } + + -- 1.3.6.1.4.1.9839.2.1.2.9 + evapPress2 OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "bar" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Circuit 2 Evaporating Pressure" + ::= { analogObjects 9 } + + -- 1.3.6.1.4.1.9839.2.1.2.10 + suctTemp1 OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Circuit 1 Suction Temperature" + ::= { analogObjects 10 } + + -- 1.3.6.1.4.1.9839.2.1.2.11 + suctTemp2 OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Circuit 2 Suction Temperature" + ::= { analogObjects 11 } + + -- 1.3.6.1.4.1.9839.2.1.2.12 + evapTemp1 OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Circuit 1 Evap.Temperature" + ::= { analogObjects 12 } + + -- 1.3.6.1.4.1.9839.2.1.2.13 + evapTemp2 OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Circuit 2 Evap.Temperature" + ::= { analogObjects 13 } + + -- 1.3.6.1.4.1.9839.2.1.2.14 + ssh1 OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Circuit 1 Superheat" + ::= { analogObjects 14 } + + -- 1.3.6.1.4.1.9839.2.1.2.15 + ssh2 OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Circuit 2 Superheat" + ::= { analogObjects 15 } + + -- 1.3.6.1.4.1.9839.2.1.2.16 + coolRamp OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Cooling Valve Ramp" + ::= { analogObjects 16 } + + -- 1.3.6.1.4.1.9839.2.1.2.17 + heatRamp OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Heating Valve Ramp" + ::= { analogObjects 17 } + + -- 1.3.6.1.4.1.9839.2.1.2.18 + fanSpeed OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Evapor. Fan Speed" + ::= { analogObjects 18 } + + -- 1.3.6.1.4.1.9839.2.1.2.20 + coolSetP OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Cooling Set Point" + ::= { analogObjects 20 } + + -- 1.3.6.1.4.1.9839.2.1.2.21 + coolDiff OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Cooling Prop.Band" + ::= { analogObjects 21 } + + -- 1.3.6.1.4.1.9839.2.1.2.22 + cool2SetP OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Cooling 2nd Set Point" + ::= { analogObjects 22 } + + -- 1.3.6.1.4.1.9839.2.1.2.23 + heatSetP OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Heating Set point" + ::= { analogObjects 23 } + + -- 1.3.6.1.4.1.9839.2.1.2.24 + heat2SetP OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Heating 2nd Set point" + ::= { analogObjects 24 } + + -- 1.3.6.1.4.1.9839.2.1.2.25 + heatDiff OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Heating Prop.Band" + ::= { analogObjects 25 } + + -- 1.3.6.1.4.1.9839.2.1.2.26 + thrsHT OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C x10" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "High Room Temperature Alarm Threshold" + ::= { analogObjects 26 } + + -- 1.3.6.1.4.1.9839.2.1.2.27 + thrsLT OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C x10" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Low Room Temperature Alarm Threshold" + ::= { analogObjects 27 } + + -- 1.3.6.1.4.1.9839.2.1.2.28 + smCoolSetp OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Setback Mode: Cooling Setpoint" + ::= { analogObjects 28 } + + -- 1.3.6.1.4.1.9839.2.1.2.29 + smHeatSetp OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Setback Mode: Heating Setpoint" + ::= { analogObjects 29 } + + -- 1.3.6.1.4.1.9839.2.1.2.30 + cwDehumSetp OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "CW Setpoint to Start Dehumidification" + ::= { analogObjects 30 } + + -- 1.3.6.1.4.1.9839.2.1.2.31 + cwHtThrsh OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "CW High Temperature Alarm Threshold" + ::= { analogObjects 31 } + + -- 1.3.6.1.4.1.9839.2.1.2.32 + cwModeSetp OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "CW Setpoint to start CW Operating Mode (Only TC Units)" + ::= { analogObjects 32 } + + -- 1.3.6.1.4.1.9839.2.1.2.33 + radcoolSpES OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Radcooler Setpoint in Energy Saving Mode" + ::= { analogObjects 33 } + + -- 1.3.6.1.4.1.9839.2.1.2.34 + radcoolSpDX OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Radcooler Setpoint in DX Mode" + ::= { analogObjects 34 } + + -- 1.3.6.1.4.1.9839.2.1.2.35 + delTempLimit OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C x10" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Delivery Temperature Low Limit Setpoint" + ::= { analogObjects 35 } + + -- 1.3.6.1.4.1.9839.2.1.2.36 + dtAutChgMLT OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "degrees C" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Delta Temperature for Automatic Mean/Local Changeover" + ::= { analogObjects 36 } + + + -- 1.3.6.1.4.1.9839.2.1.3 + integerObjects OBJECT IDENTIFIER ::= { ug40cdzMIB 3 } + + -- 1.3.6.1.4.1.9839.2.1.3.1 + filterWorkH OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "h" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Air Filter Working Houres" + ::= { integerObjects 1 } + + -- 1.3.6.1.4.1.9839.2.1.3.2 + unitWorkH OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "h" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Unit Working Houres" + ::= { integerObjects 2 } + + -- 1.3.6.1.4.1.9839.2.1.3.3 + compr1WorkH OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "h" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Compressor 1 Run Hours" + ::= { integerObjects 3 } + + -- 1.3.6.1.4.1.9839.2.1.3.4 + compr2WorkH OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "h" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Compressor 2 Run Hours" + ::= { integerObjects 4 } + + -- 1.3.6.1.4.1.9839.2.1.3.5 + compr3WorkH OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "h" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Compressor 3 Run Hours" + ::= { integerObjects 5 } + + -- 1.3.6.1.4.1.9839.2.1.3.6 + compr4WorkH OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "h" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Compressor 4 Run Hours" + ::= { integerObjects 6 } + + -- 1.3.6.1.4.1.9839.2.1.3.7 + heat1WorkH OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "h" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Heater 1 Run Hours" + ::= { integerObjects 7 } + + -- 1.3.6.1.4.1.9839.2.1.3.8 + heat2WorkH OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "h" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Heater 2 Run Hours" + ::= { integerObjects 8 } + + -- 1.3.6.1.4.1.9839.2.1.3.9 + humiWorkH OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "h" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Humidifier Run Hours" + ::= { integerObjects 9 } + + -- 1.3.6.1.4.1.9839.2.1.3.12 + dehumPband OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "rH%" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Dehumidification Prop.Band" + ::= { integerObjects 12 } + + -- 1.3.6.1.4.1.9839.2.1.3.13 + humidPband OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "rH%" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Humidification Prop.Band" + ::= { integerObjects 13 } + + -- 1.3.6.1.4.1.9839.2.1.3.14 + hhAlarmThrsh OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "rH%" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "High Humidity Alarm Threshold" + ::= { integerObjects 14 } + + -- 1.3.6.1.4.1.9839.2.1.3.15 + lhAlarmThrsh OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "rH%" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Low Humidity Alarm Threshold" + ::= { integerObjects 15 } + + -- 1.3.6.1.4.1.9839.2.1.3.16 + dehumSetp OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "rH%" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Dehumidification Setpoint" + ::= { integerObjects 16 } + + -- 1.3.6.1.4.1.9839.2.1.3.17 + smDehumSetp OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "rH%" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Setback Mode: Dehumidification Setpoint" + ::= { integerObjects 17 } + + -- 1.3.6.1.4.1.9839.2.1.3.18 + humidSetp OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "rH%" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Humidification Setpoint" + ::= { integerObjects 18 } + + -- 1.3.6.1.4.1.9839.2.1.3.19 + smHumidSetp OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "rH%" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Setback Mode: Humidification Setpoint" + ::= { integerObjects 19 } + + -- 1.3.6.1.4.1.9839.2.1.3.20 + pwOnDelay OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "s" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Restart Delay" + ::= { integerObjects 20 } + + -- 1.3.6.1.4.1.9839.2.1.3.21 + regulDelay OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "s" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Regulation Start Transitory" + ::= { integerObjects 21 } + + -- 1.3.6.1.4.1.9839.2.1.3.22 + lowPdelay OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "s" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Low Pressure Delay" + ::= { integerObjects 22 } + + -- 1.3.6.1.4.1.9839.2.1.3.23 + thAlarmdelay OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "min" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Temp./Humid.Limits Alarm Delay" + ::= { integerObjects 23 } + + -- 1.3.6.1.4.1.9839.2.1.3.24 + regExcTime OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "min" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Anti-Hunting Constant" + ::= { integerObjects 24 } + + -- 1.3.6.1.4.1.9839.2.1.3.25 + stdbyTime OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "h" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Stand-by Cycle Base Time" + ::= { integerObjects 25 } + + -- 1.3.6.1.4.1.9839.2.1.3.27 + lanUnit OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "n" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Number of LAN Units" + ::= { integerObjects 27 } + + -- 1.3.6.1.4.1.9839.2.1.3.28 + smCycleTime OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "min" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Sleep Mode Testing Cycle Time" + ::= { integerObjects 28 } + + -- 1.3.6.1.4.1.9839.2.1.3.29 + exv1steps OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "n" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Circuit 1 EXV Valve Position" + ::= { integerObjects 29 } + + -- 1.3.6.1.4.1.9839.2.1.3.30 + exv2steps OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + UNITS "n" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Circuit 2 EXV Valve Position" + ::= { integerObjects 30 } + + + + END + +-- +-- CAREL-ug40cdz.MIB +-- diff --git a/MIBS/carel/KELVIN-pCOWeb-Chiller-MIB b/MIBS/carel/KELVIN-pCOWeb-Chiller-MIB new file mode 100644 index 0000000..c0f6b4d --- /dev/null +++ b/MIBS/carel/KELVIN-pCOWeb-Chiller-MIB @@ -0,0 +1,3278 @@ +-- +-- kelvin-pCOWeb-Chiller.MIB +-- MIB generated by KELVIN +-- Friday, 13 September 2013 +-- + + KELVIN-pCOWeb-Chiller-MIB DEFINITIONS ::= BEGIN + + IMPORTS + OBJECT-GROUP + FROM SNMPv2-CONF + sysContact, sysName, sysLocation + FROM SNMPv2-MIB + enterprises, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32 + FROM SNMPv2-SMI; + + kelvin-pCOWebMIB-Chiller MODULE-IDENTITY + LAST-UPDATED "201309131602Z" -- September 13, 2013 at 16:02 GMT + ORGANIZATION "KELVIN srl / Rittal Gmbh" + CONTACT-INFO + " + KELVIN srl / Rittal Gmbh + Via delgli Imprenditori, 15 + 37067 Valeggio sul Mincio (VR) Italy + Tel: +39 045 6372711 + E-mail: info@kelvinitaly.it + " + DESCRIPTION + "This is the MIB module for the kelvin-pCOWeb-Chiller device." + REVISION "201309131602Z" -- September 13, 2013 at 16:02 GMT + DESCRIPTION "New MIB Chiller" + + ::= { instruments 1 } + + +-- +-- Node definitions +-- + + -- 1.3.6.1.4.1.9839 + carel OBJECT IDENTIFIER ::= { enterprises 9839 } + + -- 1.3.6.1.4.1.9839.1 + systm OBJECT IDENTIFIER ::= { carel 1 } + + -- 1.3.6.1.4.1.9839.1.1 + agentRelease OBJECT-TYPE + SYNTAX Integer32 + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Release of the Agent." + ::= { systm 1 } + + -- 1.3.6.1.4.1.9839.1.2 + agentCode OBJECT-TYPE + SYNTAX Integer32 + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Code of the Agent. 2=pCOWeb." + ::= { systm 2 } + + -- 1.3.6.1.4.1.9839.2 + instruments OBJECT IDENTIFIER ::= { carel 2 } + + -- 1.3.6.1.4.1.9839.2.0 + pCOWebInfo OBJECT IDENTIFIER ::= { instruments 0 } + + + -- 1.3.6.1.4.1.9839.2.0.10 + pCOStatusgroup OBJECT IDENTIFIER ::= { pCOWebInfo 10 } + + -- 1.3.6.1.4.1.9839.2.0.10.1 + pCOId1-Status OBJECT-TYPE + SYNTAX Integer32 + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Status of pCOId1. 0=Offline, 1=Init, 2=Online" + ::= { pCOStatusgroup 1 } + + -- ... You will have how many pCOIdX-Status objects as the pCOs connected to pCOWeb. + + -- 1.3.6.1.4.1.9839.2.0.11 + pCOErrorsNumbergroup OBJECT IDENTIFIER ::= { pCOWebInfo 11 } + + -- 1.3.6.1.4.1.9839.2.0.11.1 + pCOId1-ErrorsNumber OBJECT-TYPE + SYNTAX Integer32 + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of Communication Errors from pCOId1 to pCOWeb." + ::= { pCOErrorsNumbergroup 1 } + + -- ... You will have how many pCOIdX-ErrorsNumber objects as the pCOs connected to pCOWeb. + + + + -- 1.3.6.1.4.1.9839.2.1.1 + digitalObjects OBJECT IDENTIFIER ::= { kelvin-pCOWebMIB-Chiller 1 } + + -- 1.3.6.1.4.1.9839.2.1.2 + analogObjects OBJECT IDENTIFIER ::= { kelvin-pCOWebMIB-Chiller 2 } + + -- 1.3.6.1.4.1.9839.2.1.3 + integerObjects OBJECT IDENTIFIER ::= { kelvin-pCOWebMIB-Chiller 3 } + + -- DIGITAL VARIABLE + + -- 1.3.6.1.4.1.9839.2.1.1.1 + al-pa1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "High pressure switch 1 alarm" + ::= { digitalObjects 1 } + + -- 1.3.6.1.4.1.9839.2.1.1.2 + al-pa2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "High pressure switch 2 alarm" + ::= { digitalObjects 2 } + + -- 1.3.6.1.4.1.9839.2.1.1.3 + al-pb1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Low pressure switch 1 alarm" + ::= { digitalObjects 3 } + + -- 1.3.6.1.4.1.9839.2.1.1.4 + al-pb2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Low pressure switch 2 alarm" + ::= { digitalObjects 4 } + + -- 1.3.6.1.4.1.9839.2.1.1.5 + --al-ta OBJECT-TYPE + -- SYNTAX Integer32 (0..1) + -- UNITS "N/A" + -- MAX-ACCESS read-only + -- STATUS current + -- DESCRIPTION "Antifreeze alarm" + --::= { digitalObjects 5 } + + -- 1.3.6.1.4.1.9839.2.1.1.6 + al-le OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Water level alarm" + ::= { digitalObjects 6 } + + -- 1.3.6.1.4.1.9839.2.1.1.7 + --din-7 OBJECT-TYPE + -- SYNTAX Integer32 (0..1) + -- UNITS "N/A" + -- MAX-ACCESS read-only + -- STATUS current + -- DESCRIPTION "Digital input 7" + --::= { digitalObjects 7 } + + -- 1.3.6.1.4.1.9839.2.1.1.8 + al-idrofrigo-fl1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Flow switch alarm" + ::= { digitalObjects 8 } + + -- 1.3.6.1.4.1.9839.2.1.1.9 + static-press-alarm OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Water static pressure alarm" + ::= { digitalObjects 9 } + + -- 1.3.6.1.4.1.9839.2.1.1.10 + w-static-press-alarm OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Water static pressure warning" + ::= { digitalObjects 10 } + + -- 1.3.6.1.4.1.9839.2.1.1.11 + flow-value-alarm OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Flow rate alarm" + ::= { digitalObjects 11 } + + -- 1.3.6.1.4.1.9839.2.1.1.12 + al-q-comp1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overload compressor 1 circuit 1 alarm" + ::= { digitalObjects 12 } + + -- 1.3.6.1.4.1.9839.2.1.1.13 + al-q-comp2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overload compressor 2 circuit 1 alarm" + ::= { digitalObjects 13 } + + -- 1.3.6.1.4.1.9839.2.1.1.14 + al-q-comp3 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overload compressor 3 circuit 1 alarm" + ::= { digitalObjects 14 } + + -- 1.3.6.1.4.1.9839.2.1.1.15 + al-q-comp4 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overload compressor 1 circuit 2 alarm" + ::= { digitalObjects 15 } + + -- 1.3.6.1.4.1.9839.2.1.1.16 + al-q-comp5 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overload compressor 2 circuit 2 alarm" + ::= { digitalObjects 16 } + + -- 1.3.6.1.4.1.9839.2.1.1.17 + al-q-comp6 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overload compressor 3 circuit 2 alarm" + ::= { digitalObjects 17 } + + -- 1.3.6.1.4.1.9839.2.1.1.18 + al-q-fan-1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overload fans circuit 1" + ::= { digitalObjects 18 } + + -- 1.3.6.1.4.1.9839.2.1.1.19 + al-q-fan-2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overload fans circuit 2" + ::= { digitalObjects 19 } + + -- 1.3.6.1.4.1.9839.2.1.1.20 + al-q-fan11 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overload fan 1 circuit 1 alarm" + ::= { digitalObjects 20 } + + -- 1.3.6.1.4.1.9839.2.1.1.21 + al-q-fan12 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overload fan 2 circuit 1 alarm" + ::= { digitalObjects 21 } + + -- 1.3.6.1.4.1.9839.2.1.1.22 + al-q-fan13 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overload fan 3 circuit 1 alarm" + ::= { digitalObjects 22 } + + -- 1.3.6.1.4.1.9839.2.1.1.23 + al-q-fan14 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overload fan 4 circuit 1 alarm" + ::= { digitalObjects 23 } + + -- 1.3.6.1.4.1.9839.2.1.1.24 + al-q-fan21 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overload fan 1 circuit 2 alarm" + ::= { digitalObjects 24 } + + -- 1.3.6.1.4.1.9839.2.1.1.25 + al-q-fan22 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overload fan 2 circuit 2 alarm" + ::= { digitalObjects 25 } + + -- 1.3.6.1.4.1.9839.2.1.1.26 + al-q-fan-23 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overload fan 3 circuit 2 alarm" + ::= { digitalObjects 26 } + + -- 1.3.6.1.4.1.9839.2.1.1.27 + al-q-fan24 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overload fan 4 circuit 2 alarm" + ::= { digitalObjects 27 } + + -- 1.3.6.1.4.1.9839.2.1.1.28 + al-idrofrigo-pump1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overload pump 1 alarm" + ::= { digitalObjects 28 } + + -- 1.3.6.1.4.1.9839.2.1.1.29 + al-idrofrigo-pump2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overload pump 2 alarm" + ::= { digitalObjects 29 } + + -- 1.3.6.1.4.1.9839.2.1.1.30 + al-phase-cont OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Wrong phase rotation alarm" + ::= { digitalObjects 30 } + + -- 1.3.6.1.4.1.9839.2.1.1.31 + al-door-sw OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Back Door open alarm" + ::= { digitalObjects 31 } + + -- 1.3.6.1.4.1.9839.2.1.1.32 + compressor-FlowRate OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Compressor FlowRate Management" + ::= { digitalObjects 32 } + + -- 1.3.6.1.4.1.9839.2.1.1.33 + setpoint-inv-pumps OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Setpoint Type for Inverter pumps" + ::= { digitalObjects 33 } + + -- 1.3.6.1.4.1.9839.2.1.1.34 + enable-pumps-redundance OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable Pumps redundance" + ::= { digitalObjects 34 } + + -- 1.3.6.1.4.1.9839.2.1.1.35 + enable-chiller-redundance OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable Chiller redundance" + ::= { digitalObjects 35 } + + -- 1.3.6.1.4.1.9839.2.1.1.36 + status-in-alarm OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Status in alarm" + ::= { digitalObjects 36 } + + -- 1.3.6.1.4.1.9839.2.1.1.37 + compressor-recovery OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Compressor Recovery" + ::= { digitalObjects 37 } + + -- 1.3.6.1.4.1.9839.2.1.1.38 + enable-thermal-redundance OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable Thermal redundance" + ::= { digitalObjects 38 } + + -- 1.3.6.1.4.1.9839.2.1.1.39 + enable-multi-pumps-function OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable multi-pumps function" + ::= { digitalObjects 39 } + + -- 1.3.6.1.4.1.9839.2.1.1.40 + enable-pumps-offline OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable function pumps-Offline" + ::= { digitalObjects 40 } + + -- 1.3.6.1.4.1.9839.2.1.1.41 + enable-3way-valve OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable 3way valve" + ::= { digitalObjects 41 } + + -- 1.3.6.1.4.1.9839.2.1.1.42 + enable-speed-up-FCM OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable speed-up FCM" + ::= { digitalObjects 42 } + + -- 1.3.6.1.4.1.9839.2.1.1.43 + enable-soft-start-FCM OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable soft-start FCM" + ::= { digitalObjects 43 } + + -- 1.3.6.1.4.1.9839.2.1.1.44 + enable-freecooling OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable Freecooling" + ::= { digitalObjects 44} + + -- 1.3.6.1.4.1.9839.2.1.1.45 + enable-rot-FIFO-FC OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable rotation FIFO Freecooling" + ::= { digitalObjects 45} + + -- 1.3.6.1.4.1.9839.2.1.1.46 + enable-HT-function OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable HT-function" + ::= { digitalObjects 46 } + + -- 1.3.6.1.4.1.9839.2.1.1.47 + enable-PID-Fc-valve OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable PID-regulation for Freecooling valve" + ::= { digitalObjects 47 } + + -- 1.3.6.1.4.1.9839.2.1.1.48 + enable-Fc-Thermal-Exclusion OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable Freecooling Thermal Exclusion" + ::= { digitalObjects 48 } + + -- 1.3.6.1.4.1.9839.2.1.1.49 + manual-Reset-Ext-Drycooler-Alarm OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Manual Reset External Dry-cooler Alarm" + ::= { digitalObjects 49 } + + + -- 1.3.6.1.4.1.9839.2.1.1.50 + enable-static-press-Alarm OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable static pressure Alarm" + ::= { digitalObjects 50 } + + -- 1.3.6.1.4.1.9839.2.1.1.51 + manual-reset-static-press-Alarm OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Manual reset static pressure Alarm" + ::= { digitalObjects 51 } + + -- 1.3.6.1.4.1.9839.2.1.1.52 + enable-static-press-Warning OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable static pressure Warning" + ::= { digitalObjects 52 } + + -- 1.3.6.1.4.1.9839.2.1.1.53 + manual-reset-static-press-Warning OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Manual reset static pressure Warning" + ::= { digitalObjects 53 } + + -- 1.3.6.1.4.1.9839.2.1.1.54 + enable-diff-press-Alarm OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable differential pressure Alarm" + ::= { digitalObjects 54 } + + -- 1.3.6.1.4.1.9839.2.1.1.55 + manual-reset-diff-press-Alarm OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Manual reset differential pressure Alarm" + ::= { digitalObjects 55 } + + -- 1.3.6.1.4.1.9839.2.1.1.56 + enable-pressure-recovery OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable pressure recovery" + ::= { digitalObjects 56 } + + -- 1.3.6.1.4.1.9839.2.1.1.57 + enable-Flow-Rate-Alarm OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable Flow-Rate Alarm" + ::= { digitalObjects 57 } + + -- 1.3.6.1.4.1.9839.2.1.1.58 + manual-reset-Flow-Rate-Alarm OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Manual reset Flow-Rate Alarm" + ::= { digitalObjects 58 } + + -- 1.3.6.1.4.1.9839.2.1.1.59 + enable-Flow-Rate-recovery OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable Flow-Rate recovery" + ::= { digitalObjects 59 } + + -- 1.3.6.1.4.1.9839.2.1.1.60 + enable-pCOWeb OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable pCOWeb" + ::= { digitalObjects 60 } + + -- 1.3.6.1.4.1.9839.2.1.1.61 + fc-single-chiller OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Freecooling single chiller function" + ::= { digitalObjects 61 } + + + + --new index + + -- 1.3.6.1.4.1.9839.2.1.1.75 + al-idrofrigo-pump-c-1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Condensation pump 1 breaker switch alarm" + ::= { digitalObjects 75 } + + -- 1.3.6.1.4.1.9839.2.1.1.76 + al-idrofrigo-pump-c-2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Condensation pump 2 breaker switch alarm" + ::= { digitalObjects 76 } + + + -- 1.3.6.1.4.1.9839.2.1.1.80 + al-idrofrigo-fl-C OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Condensation flow switch alarm" + ::= { digitalObjects 80 } + + --new end + + + + + -- 1.3.6.1.4.1.9839.2.1.1.100 + c11-on OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Compressor 1 circuit 1 ON" + ::= { digitalObjects 100 } + + -- 1.3.6.1.4.1.9839.2.1.1.101 + c12-on OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Compressor 2 circuit 1 ON" + ::= { digitalObjects 101 } + + -- 1.3.6.1.4.1.9839.2.1.1.102 + c13-on OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Compressor 3 circuit 1 ON" + ::= { digitalObjects 102 } + + -- 1.3.6.1.4.1.9839.2.1.1.103 + c21-on OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Compressor 1 circuit 2 ON" + ::= { digitalObjects 103 } + + -- 1.3.6.1.4.1.9839.2.1.1.104 + c22-on OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Compressor 2 circuit 2 ON" + ::= { digitalObjects 104 } + + -- 1.3.6.1.4.1.9839.2.1.1.105 + c23-on OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Compressor 3 circuit 2 ON" + ::= { digitalObjects 105 } + + -- 1.3.6.1.4.1.9839.2.1.1.106 + pump1-on OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Pump 1 ON" + ::= { digitalObjects 106 } + + -- 1.3.6.1.4.1.9839.2.1.1.107 + pump2-on OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Pump 2 ON" + ::= { digitalObjects 107 } + + -- 1.3.6.1.4.1.9839.2.1.1.108 + on-fan-gr1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Fans group 1 ON" + ::= { digitalObjects 108 } + + -- 1.3.6.1.4.1.9839.2.1.1.109 + on-fan-gr2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Fans group 2 ON" + ::= { digitalObjects 109 } + + -- 1.3.6.1.4.1.9839.2.1.1.110 + fc-on OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Freecooling or external dry-cooler 1 ON" + ::= { digitalObjects 110 } + + -- 1.3.6.1.4.1.9839.2.1.1.130 + en-on-off-rem OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Remote on-off" + ::= { digitalObjects 130 } + + -- 1.3.6.1.4.1.9839.2.1.1.131 + unit-on OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Chiller ON" + ::= { digitalObjects 131 } + + + --new index + + -- 1.3.6.1.4.1.9839.2.1.1.148 + disch-alarm-scw-1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Discharge screw compressor 1 alarm" + ::= { digitalObjects 148 } + + -- 1.3.6.1.4.1.9839.2.1.1.149 + disch-alarm-scw-2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Discharge screw compressor 2 alarm" + ::= { digitalObjects 149 } + + + -- 1.3.6.1.4.1.9839.2.1.1.150 + al-probe-inlet OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Inlet probe alarm (broken or disconnected)" + ::= { digitalObjects 150 } + + + -- 1.3.6.1.4.1.9839.2.1.1.151 + al-probe-amb OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Ambient probe alarm (broken or disconnected)" + ::= { digitalObjects 151 } + + + -- 1.3.6.1.4.1.9839.2.1.1.152 + al-frigo-fl1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Flow switch alarm (cooling alarm)" + ::= { digitalObjects 152 } + + + -- 1.3.6.1.4.1.9839.2.1.1.153 + al-idro-pump1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Pump 1 hydraulic alarm" + ::= { digitalObjects 153 } + + + -- 1.3.6.1.4.1.9839.2.1.1.154 + al-idro-pump2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Pump 2 hydraulic alarm" + ::= { digitalObjects 154 } + + + -- 1.3.6.1.4.1.9839.2.1.1.155 + al-idro-fl1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Flow switch alarm (hydraulic alarm)" + ::= { digitalObjects 155 } + + + -- 1.3.6.1.4.1.9839.2.1.1.156 + al-warning-fl1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Flow switch alarm (warning alarm)" + ::= { digitalObjects 156 } + + + -- 1.3.6.1.4.1.9839.2.1.1.157 + al-hi-water-temp OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "High Temperature alarm" + ::= { digitalObjects 157 } + + + -- 1.3.6.1.4.1.9839.2.1.1.158 + al-lo-water-temp OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Low Temperature alarm" + ::= { digitalObjects 158 } + + -- 1.3.6.1.4.1.9839.2.1.1.159 + al-ta-probe1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Antifreeze/evaporator probe 1 alarm" + ::= { digitalObjects 159 } + + + -- 1.3.6.1.4.1.9839.2.1.1.160 + al-hi-press OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "High condensation pressure alarm" + ::= { digitalObjects 160 } + + -- 1.3.6.1.4.1.9839.2.1.1.161 + al-lo-press OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Low condensation pressure alarm" + ::= { digitalObjects 161 } + + + -- 1.3.6.1.4.1.9839.2.1.1.162 + al-probe-evap-1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Antifreeze/evaporator probe 1 alarm (broken or disconnected)" + ::= { digitalObjects 162 } + + + -- 1.3.6.1.4.1.9839.2.1.1.163 + al-probe-evap-2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Antifreeze/evaporator probe 2 alarm (broken or disconnected)" + ::= { digitalObjects 163 } + + + -- 1.3.6.1.4.1.9839.2.1.1.164 + al-hi-press-1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "High condensation pressure 1 alarm" + ::= { digitalObjects 164 } + + + -- 1.3.6.1.4.1.9839.2.1.1.165 + al-hi-press-2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "High condensation pressure 2 alarm" + ::= { digitalObjects 165 } + + + -- 1.3.6.1.4.1.9839.2.1.1.166 + al-lo-press-1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Low condensation pressure 1 alarm" + ::= { digitalObjects 166 } + + + -- 1.3.6.1.4.1.9839.2.1.1.167 + al-lo-press-2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Low condensation pressure 2 alarm" + ::= { digitalObjects 167 } + + + -- 1.3.6.1.4.1.9839.2.1.1.168 + al-probe-tank OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Tank/Out probe alarm (broken or disconnected)" + ::= { digitalObjects 168 } + + + -- 1.3.6.1.4.1.9839.2.1.1.169 + off-line-1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Chiller 1 offline" + ::= { digitalObjects 169 } + + -- 1.3.6.1.4.1.9839.2.1.1.170 + off-line-2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Chiller 2 offline" + ::= { digitalObjects 170 } + + -- 1.3.6.1.4.1.9839.2.1.1.171 + off-line-3 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Chiller 3 offline" + ::= { digitalObjects 171 } + + -- 1.3.6.1.4.1.9839.2.1.1.172 + off-line-4 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Chiller 4 offline" + ::= { digitalObjects 172 } + + -- 1.3.6.1.4.1.9839.2.1.1.173 + off-line-5 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Chiller 5 offline" + ::= { digitalObjects 173 } + + + -- 1.3.6.1.4.1.9839.2.1.1.174 + off-line-6 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Chiller 6 offline" + ::= { digitalObjects 174 } + + -- 1.3.6.1.4.1.9839.2.1.1.175 + off-line-7 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Chiller 7 offline" + ::= { digitalObjects 175 } + + -- 1.3.6.1.4.1.9839.2.1.1.176 + off-line-8 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Chiller 8 offline" + ::= { digitalObjects 176 } + + -- 1.3.6.1.4.1.9839.2.1.1.177 + al-ta-probe2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Antifreeze/evaporator probe 2 alarm" + ::= { digitalObjects 177 } + + + -- 1.3.6.1.4.1.9839.2.1.1.178 + al-sms OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "SMS alarm" + ::= { digitalObjects 178 } + + + -- 1.3.6.1.4.1.9839.2.1.1.179 + al-modem OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Modem alarm" + ::= { digitalObjects 179 } + + + -- 1.3.6.1.4.1.9839.2.1.1.180 + sms-coda-alarm OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "SMS coda alarm" + ::= { digitalObjects 180 } + + + -- 1.3.6.1.4.1.9839.2.1.1.181 + al-probe-fc OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Freecooling probe alarm (broken or disconnected)" + ::= { digitalObjects 181 } + + + -- 1.3.6.1.4.1.9839.2.1.1.182 + al-maint-pw1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Maintenance pump 1 alarm)" + ::= { digitalObjects 182 } + + -- 1.3.6.1.4.1.9839.2.1.1.183 + al-maint-pw2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Maintenance pump 2 alarm)" + ::= { digitalObjects 183 } + + + -- 1.3.6.1.4.1.9839.2.1.1.184 + al-hi-temp-rid OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "High temperature alarm (redundance)" + ::= { digitalObjects 184 } + + -- 1.3.6.1.4.1.9839.2.1.1.185 + al-q-fc-sep OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DryCooler breaker switch alarm" + ::= { digitalObjects 185 } + + -- 1.3.6.1.4.1.9839.2.1.1.186 + al-p-wat2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Water pressure 2 alarm" + ::= { digitalObjects 186 } + + + -- 1.3.6.1.4.1.9839.2.1.1.187 + al-p-wat1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Water pressure 1 alarm" + ::= { digitalObjects 187 } + + + -- 1.3.6.1.4.1.9839.2.1.1.188 + al-foult-flow-p1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Pump 1 flow alarm" + ::= { digitalObjects 188 } + + + -- 1.3.6.1.4.1.9839.2.1.1.189 + al-foult-flow-p2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Pump 2 flow alarm" + ::= { digitalObjects 189 } + + -- 1.3.6.1.4.1.9839.2.1.1.190 + al-foult-fl1-p1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Pump 1 flow-switch alarm" + ::= { digitalObjects 190 } + + -- 1.3.6.1.4.1.9839.2.1.1.191 + al-foult-fl1-p2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Pump 2 flow-switch alarm" + ::= { digitalObjects 191 } + + -- 1.3.6.1.4.1.9839.2.1.1.192 + al-warning-le OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Water level warning" + ::= { digitalObjects 192 } + + + -- 1.3.6.1.4.1.9839.2.1.1.193 + al-frigo-fl-C OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Flow switch condensation alarm (cooling alarm)" + ::= { digitalObjects 193 } + + -- 1.3.6.1.4.1.9839.2.1.1.194 + al-idro-pump-c-1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Pump 1 condensation hydraulic alarm" + ::= { digitalObjects 194 } + + -- 1.3.6.1.4.1.9839.2.1.1.195 + al-idro-pump-c-2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Pump 2 condensation hydraulic alarm" + ::= { digitalObjects 195 } + + + -- 1.3.6.1.4.1.9839.2.1.1.196 + al-idro-fl-C OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Flow switch condensation alarm (hydraulic alarm)" + ::= { digitalObjects 196 } + + -- 1.3.6.1.4.1.9839.2.1.1.197 + al-warning-fl-C OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Flow switch condensation alarm (warning alarm)" + ::= { digitalObjects 197 } + + -- 1.3.6.1.4.1.9839.2.1.1.198 + al-foul-fl-C-p1 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Pump 1 condensation flow-switch alarm" + ::= { digitalObjects 198 } + + -- 1.3.6.1.4.1.9839.2.1.1.199 + al-foul-fl-C-p2 OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Pump 2 condensation flow-switch alarm" + ::= { digitalObjects 199 } + + + --new end + + + + + -- ANALOG VARIABLE + + -- 1.3.6.1.4.1.9839.2.1.2.1 + setpoint-antifreeze1 OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Setpoint Antifreeze 1" + ::= { analogObjects 1 } + + -- 1.3.6.1.4.1.9839.2.1.2.2 + setpoint-antifreeze2 OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Setpoint Antifreeze 2" + ::= { analogObjects 2 } + + -- 1.3.6.1.4.1.9839.2.1.2.3 + setpoint-Compensation OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Setpoint Compensation" + ::= { analogObjects 3 } + + -- 1.3.6.1.4.1.9839.2.1.2.4 + hysteresis-Compensation OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Hysteresis Compensation" + ::= { analogObjects 4 } + + -- 1.3.6.1.4.1.9839.2.1.2.5 + max-Compensation OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Max. Compensation" + ::= { analogObjects 5 } + + -- 1.3.6.1.4.1.9839.2.1.2.6 + setpoint-Differential OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Setpoint Differential" + ::= { analogObjects 6 } + + -- 1.3.6.1.4.1.9839.2.1.2.7 + high-Limit OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "High Limit" + ::= { analogObjects 7 } + + -- 1.3.6.1.4.1.9839.2.1.2.8 + low-Limit OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Low Limit" + ::= { analogObjects 8 } + + -- 1.3.6.1.4.1.9839.2.1.2.9 + max-Setpoint-Differential OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Max. Setpoint Differential" + ::= { analogObjects 9 } + + -- 1.3.6.1.4.1.9839.2.1.2.10 + min-Setpoint-Differential OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Min. Setpoint Differential" + ::= { analogObjects 10 } + + -- 1.3.6.1.4.1.9839.2.1.2.11 + setpoint-ASB-Inverter-pumps OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Setpoint ASB Inverter pumps" + ::= { analogObjects 11 } + + -- 1.3.6.1.4.1.9839.2.1.2.12 + setpoint-DIFF-Inverter-pumps OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Setpoint DIFF Inverter pumps" + ::= { analogObjects 12 } + + -- 1.3.6.1.4.1.9839.2.1.2.13 + pressure-Out OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Pressure Out" + ::= { analogObjects 13 } + + -- 1.3.6.1.4.1.9839.2.1.2.14 + proportional-Band-Inverter-Pumps-PID OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Proportional Band Inverter Pumps PID" + ::= { analogObjects 14 } + + -- 1.3.6.1.4.1.9839.2.1.2.15 + integral-Time-Inverter-Pumps-PID OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Integral Time Inverter Pumps PID" + ::= { analogObjects 15 } + + -- 1.3.6.1.4.1.9839.2.1.2.16 + derivative-Time-Inverter-Pumps-PID OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Derivative Time Inverter Pumps PID" + ::= { analogObjects 16 } + + -- 1.3.6.1.4.1.9839.2.1.2.17 + hysteresis-Thermal-redundance OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Hysteresis Thermal redundance" + ::= { analogObjects 17 } + + -- 1.3.6.1.4.1.9839.2.1.2.18 + min-Opening-3Way-Valve-Hydraulic OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Min. Opening 3Way Valve Hydraulic" + ::= { analogObjects 18 } + + -- 1.3.6.1.4.1.9839.2.1.2.19 + max-Opening-3Way-Valve-Hydraulic OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Max. Opening 3Way Valve Hydraulic" + ::= { analogObjects 19 } + + -- 1.3.6.1.4.1.9839.2.1.2.20 + proportional-Band-3Way-Valve-Hydrauli-PID OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Proportional Band 3Way Valve Hydraulic PID" + ::= { analogObjects 20 } + + + -- 1.3.6.1.4.1.9839.2.1.2.21 + setpoint-FCM OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Setpoint FCM" + ::= { analogObjects 21 } + + -- 1.3.6.1.4.1.9839.2.1.2.22 + hysteresis-FCM OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Hysteresis FCM" + ::= { analogObjects 22 } + + -- 1.3.6.1.4.1.9839.2.1.2.23 + max-Out-Speed-FCM OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Max. Out Speed FCM" + ::= { analogObjects 23 } + + -- 1.3.6.1.4.1.9839.2.1.2.24 + min-Out-Speed-FCM OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Min. Out Speed FCM" + ::= { analogObjects 24 } + + -- 1.3.6.1.4.1.9839.2.1.2.25 + hysteresis-Cut-off-FCM OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Hysteresis Cut-off FCM" + ::= { analogObjects 25 } + + -- 1.3.6.1.4.1.9839.2.1.2.26 + max-Pressure-Alarm-FCM OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Max. Pressure Alarm FCM" + ::= { analogObjects 26 } + + -- 1.3.6.1.4.1.9839.2.1.2.27 + hysteresis-Max-Pressure-Alarm-FCM OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Hysteresis Max.Pressure Alarm FCM" + ::= { analogObjects 27 } + + -- 1.3.6.1.4.1.9839.2.1.2.28 + max-Out-FCM OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Max. Out FCM" + ::= { analogObjects 28 } + + -- 1.3.6.1.4.1.9839.2.1.2.29 + min-Pressure-Alarm-FCM OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Min. Pressure Alarm FCM" + ::= { analogObjects 29 } + + -- 1.3.6.1.4.1.9839.2.1.2.30 + hysteresis-Min-Pressure-Alarm-FCM OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Hysteresis Min.Pressure Alarm FCM" + ::= { analogObjects 30 } + + -- 1.3.6.1.4.1.9839.2.1.2.31 + min-Out-FCM OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Min. Out FCM" + ::= { analogObjects 31 } + + -- 1.3.6.1.4.1.9839.2.1.2.32 + delta-Freecooling OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Delta Freecooling" + ::= { analogObjects 32 } + + -- 1.3.6.1.4.1.9839.2.1.2.33 + hysteresis-Freecooling OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Hysteresis Freecooling" + ::= { analogObjects 33 } + + -- 1.3.6.1.4.1.9839.2.1.2.34 + proportional-Band-Freecooling-PID OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Proportional Band Freecooling PID" + ::= { analogObjects 34 } + + -- 1.3.6.1.4.1.9839.2.1.2.35 + offset-Freecooling-PID OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Offset Freecooling PID" + ::= { analogObjects 35 } + + -- 1.3.6.1.4.1.9839.2.1.2.36 + temperature-Overlap-Freecooling OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Temperature Overlap Freecooling" + ::= { analogObjects 36 } + + -- 1.3.6.1.4.1.9839.2.1.2.37 + min-out-freecooling OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Min. out freecooling" + ::= { analogObjects 37 } + + -- 1.3.6.1.4.1.9839.2.1.2.38 + neutral-zone-K-costant OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Neutral zone K costant" + ::= { analogObjects 38 } + + -- 1.3.6.1.4.1.9839.2.1.2.39 + neutral-zone-V-variable OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Neutral zone V variable" + ::= { analogObjects 39 } + + -- 1.3.6.1.4.1.9839.2.1.2.40 + proportional-Band-freecooling-Valve-PID OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Proportional Band freecooling Valve PID" + ::= { analogObjects 40 } + + -- 1.3.6.1.4.1.9839.2.1.2.41 + offset-Freecooling-Valve-PID OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Offset Freecooling Valve PID" + ::= { analogObjects 41 } + + -- 1.3.6.1.4.1.9839.2.1.2.42 + temperature-A-B OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Temperature A-B" + ::= { analogObjects 42 } + + -- 1.3.6.1.4.1.9839.2.1.2.43 + delta-Thermal-Excusion-Freecoling OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Delta Thermal Excusion Freecoling" + ::= { analogObjects 43 } + + -- 1.3.6.1.4.1.9839.2.1.2.44 + hysteresis-Thermal-Excusion-Freecoling OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "hysteresis Thermal Excusion Freecoling" + ::= { analogObjects 44 } + + -- 1.3.6.1.4.1.9839.2.1.2.45 + alarm-Setpoint-Static-Pressure-Hydraulic-circuit OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Alarm Setpoint Static Pressure Hydraulic circuit" + ::= { analogObjects 45 } + + -- 1.3.6.1.4.1.9839.2.1.2.46 + warnig-Setpoint-Static-Pressure-Hydraulic-circuit OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Warnig Setpoint Static Pressure Hydraulic circuit" + ::= { analogObjects 46 } + + -- 1.3.6.1.4.1.9839.2.1.2.47 + alarm-Setpoint-Differential-Pressure-Hydraulic-circuit OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Alarm Setpoint Differential Pressure Hydraulic circuit" + ::= { analogObjects 47 } + + -- 1.3.6.1.4.1.9839.2.1.2.48 + alarm-Setpoint-Flow-Rate-Hydraulic-circuit OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Alarm Setpoint Flow-Rate Hydraulic circuit" + ::= { analogObjects 48 } + + + + + -- 1.3.6.1.4.1.9839.2.1.2.50 + tempertaure-Cut-off-FCM OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Tempertaure Cut-off FCM" + ::= { analogObjects 50 } + + + -- 1.3.6.1.4.1.9839.2.1.2.59 + set-effective OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Set-effective" + ::= { analogObjects 59 } + + + + + -- 1.3.6.1.4.1.9839.2.1.2.60 + set-fc OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Freecooling or drycooler Set-point" + ::= { analogObjects 60 } + + -- 1.3.6.1.4.1.9839.2.1.2.61 + setpoint-a-us OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Set-point MAIN" + ::= { analogObjects 61 } + + -- 1.3.6.1.4.1.9839.2.1.2.62 + max-setpoint OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Max.setpoint" + ::= { analogObjects 62 } + + -- 1.3.6.1.4.1.9839.2.1.2.63 + min-setpoint OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Min.setpoint" + ::= { analogObjects 63 } + + -- 1.3.6.1.4.1.9839.2.1.2.64 + diff OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "differential" + ::= { analogObjects 64 } + + -- 1.3.6.1.4.1.9839.2.1.2.65 + max-diff OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Max. differential" + ::= { analogObjects 65 } + + -- 1.3.6.1.4.1.9839.2.1.2.66 + min-diff OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Min.Differential" + ::= { analogObjects 66 } + + -- 1.3.6.1.4.1.9839.2.1.2.67 + fcs-out OBJECT-TYPE + SYNTAX Integer32 (0..1000) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Fans speed controller output %" + ::= { analogObjects 67 } + + -- 1.3.6.1.4.1.9839.2.1.2.70 + water-temp OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Tank - Process water temperature" + ::= { analogObjects 70 } + + -- 1.3.6.1.4.1.9839.2.1.2.71 + temp-inlet OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Water inlet temperature" + ::= { analogObjects 71 } + + -- 1.3.6.1.4.1.9839.2.1.2.72 + temp-outlet OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Water outlet temperature" + ::= { analogObjects 72 } + + -- 1.3.6.1.4.1.9839.2.1.2.73 + flow-value OBJECT-TYPE + SYNTAX Integer32 (-9999..9999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Flow rate value" + ::= { analogObjects 73 } + + -- 1.3.6.1.4.1.9839.2.1.2.74 + amp-value OBJECT-TYPE + SYNTAX Integer32 (-9999..9999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current cunsumption" + ::= { analogObjects 74 } + + -- 1.3.6.1.4.1.9839.2.1.2.75 + ta-probe-temp-1 OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Antifreeze 1 temperature monitoring " + ::= { analogObjects 75 } + + -- 1.3.6.1.4.1.9839.2.1.2.76 + ta-probe-temp-2 OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Antifreeze 2 temperature monitoring" + ::= { analogObjects 76 } + + -- 1.3.6.1.4.1.9839.2.1.2.77 + pressione1 OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Condensation pressure circuit 1" + ::= { analogObjects 77 } + + -- 1.3.6.1.4.1.9839.2.1.2.78 + pressione2 OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Condensation pressure circuit 2" + ::= { analogObjects 78 } + + -- 1.3.6.1.4.1.9839.2.1.2.79 + pump-sp-press OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Pump discharge pressure " + ::= { analogObjects 79 } + + -- 1.3.6.1.4.1.9839.2.1.2.80 + p-wat2 OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Pump suction or static pressure" + ::= { analogObjects 80 } + + -- 1.3.6.1.4.1.9839.2.1.2.81 + temp-amb OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Ambient temperature" + ::= { analogObjects 81 } + + -- 1.3.6.1.4.1.9839.2.1.2.82 + temp-fc OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Inlet - freecooling temperature" + ::= { analogObjects 82 } + + + + -- 1.3.6.1.4.1.9839.2.1.2.90 + pp1 OBJECT-TYPE + SYNTAX Integer32 (0..100) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Pump 1 speed" + ::= { analogObjects 90 } + + -- 1.3.6.1.4.1.9839.2.1.2.91 + pp2 OBJECT-TYPE + SYNTAX Integer32 (0..100) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Pump 2 speed" + ::= { analogObjects 91 } + + + -- 1.3.6.1.4.1.9839.2.1.2.100 + cooling-capacity OBJECT-TYPE + SYNTAX Integer32 (0..9999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Cooling Capacity" + ::= { analogObjects 100 } + + -- 1.3.6.1.4.1.9839.2.1.2.101 + freecooling-capacity OBJECT-TYPE + SYNTAX Integer32 (0..9999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "FreeCooling Capacity" + ::= { analogObjects 101 } + + -- 1.3.6.1.4.1.9839.2.1.2.102 + total-capacity OBJECT-TYPE + SYNTAX Integer32 (0..9999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "TotalCooling Capacity" + ::= { analogObjects 102 } + + + + + -- INTEGER VARIABLE + + -- 1.3.6.1.4.1.9839.2.1.3.6 + ip-Address1 OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IP Address 1 (XXX.xxx.xxx.xxx)" + ::= { integerObjects 6 } + + -- 1.3.6.1.4.1.9839.2.1.3.7 + ip-Address2 OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IP Address 2 (xxx.XXX.xxx.xxx)" + ::= { integerObjects 7 } + + -- 1.3.6.1.4.1.9839.2.1.3.8 + ip-Address3 OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IP Address 3 (xxx.xxx.XXX.xxx)" + ::= { integerObjects 8 } + + -- 1.3.6.1.4.1.9839.2.1.3.9 + ip-Address4 OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IP Address 4 (xxx.xxx.xxx.XXX)" + ::= { integerObjects 9 } + + -- 1.3.6.1.4.1.9839.2.1.3.10 + netMask OBJECT-TYPE + SYNTAX Integer32 (8..32) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "NetMask 8-16-24-32" + ::= { integerObjects 10 } + + -- 1.3.6.1.4.1.9839.2.1.3.11 + gateway1 OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Gateway 1 (XXX.xxx.xxx.xxx)" + ::= { integerObjects 11 } + + -- 1.3.6.1.4.1.9839.2.1.3.12 + gateway2 OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Gateway 2 (xxx.XXX.xxx.xxx)" + ::= { integerObjects 12 } + + -- 1.3.6.1.4.1.9839.2.1.3.13 + gateway3 OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Gateway 3 (xxx.xxx.XXX.xxx)" + ::= { integerObjects 13 } + + -- 1.3.6.1.4.1.9839.2.1.3.14 + gateway4 OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Gateway 4 (xxx.xxx.xxx.XXX)" + ::= { integerObjects 14 } + + + -- 1.3.6.1.4.1.9839.2.1.3.15 + dns1-1 OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DNS (1) 1 (XXX.xxx.xxx.xxx)" + ::= { integerObjects 15 } + + -- 1.3.6.1.4.1.9839.2.1.3.16 + dns1-2 OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DNS (1) 2 (xxx.XXX.xxx.xxx)" + ::= { integerObjects 16 } + + -- 1.3.6.1.4.1.9839.2.1.3.17 + dns1-3 OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DNS (1) 3 (xxx.xxx.XXX.xxx)" + ::= { integerObjects 17 } + + -- 1.3.6.1.4.1.9839.2.1.3.18 + dns1-4 OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DNS (1) 4 (xxx.xxx.xxx.XXX)" + ::= { integerObjects 18 } + + + -- 1.3.6.1.4.1.9839.2.1.3.19 + dns2-1 OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DNS (2) 1 (XXX.xxx.xxx.xxx)" + ::= { integerObjects 19 } + + -- 1.3.6.1.4.1.9839.2.1.3.20 + dns2-2 OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DNS (2) 2 (xxx.XXX.xxx.xxx)" + ::= { integerObjects 20 } + + -- 1.3.6.1.4.1.9839.2.1.3.21 + dns2-3 OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DNS (2) 3 (xxx.xxx.XXX.xxx)" + ::= { integerObjects 21 } + + -- 1.3.6.1.4.1.9839.2.1.3.22 + dns2-4 OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DNS (2) 4 (xxx.xxx.xxx.XXX)" + ::= { integerObjects 22 } + + + + + + + + -- 1.3.6.1.4.1.9839.2.1.3.26 + ip-Address1-Out OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IP Address Out 1 (XXX.xxx.xxx.xxx)" + ::= { integerObjects 26 } + + -- 1.3.6.1.4.1.9839.2.1.3.27 + ip-Address2-Out OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IP Address Out 2 (xxx.XXX.xxx.xxx)" + ::= { integerObjects 27 } + + -- 1.3.6.1.4.1.9839.2.1.3.28 + ip-Address3-Out OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IP Address Out 3 (xxx.xxx.XXX.xxx)" + ::= { integerObjects 28 } + + -- 1.3.6.1.4.1.9839.2.1.3.29 + ip-Address4-Out OBJECT-TYPE + SYNTAX Integer32 (1..255) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IP Address Out 4 (xxx.xxx.xxx.XXX)" + ::= { integerObjects 29 } + + + + -- 1.3.6.1.4.1.9839.2.1.3.30 + starting-delay-Second-Pump OBJECT-TYPE + SYNTAX Integer32 (0..99) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Starting delay Second Pump" + ::= { integerObjects 30 } + + -- 1.3.6.1.4.1.9839.2.1.3.31 + starting-delay-btw-Pump-Compressor OBJECT-TYPE + SYNTAX Integer32 (0..32767) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Starting delay btw Pump - Compressor" + ::= { integerObjects 31 } + + -- 1.3.6.1.4.1.9839.2.1.3.32 + overlap-time-Pumps OBJECT-TYPE + SYNTAX Integer32 (0..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Overlap time Pumps" + ::= { integerObjects 32 } + + -- 1.3.6.1.4.1.9839.2.1.3.33 + working-time-Pumps OBJECT-TYPE + SYNTAX Integer32 (1..9999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Working time Pumps" + ::= { integerObjects 33 } + + -- 1.3.6.1.4.1.9839.2.1.3.34 + running-time-Chillers OBJECT-TYPE + SYNTAX Integer32 (0..32767) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Running time Chillers" + ::= { integerObjects 34 } + + -- 1.3.6.1.4.1.9839.2.1.3.35 + overlap-time-Chillers OBJECT-TYPE + SYNTAX Integer32 (0..32767) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Overlap time Chillers" + ::= { integerObjects 35 } + + -- 1.3.6.1.4.1.9839.2.1.3.36 + n-chillers-Max OBJECT-TYPE + SYNTAX Integer32 (1..8) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "N chillers Max" + ::= { integerObjects 36 } + + -- 1.3.6.1.4.1.9839.2.1.3.37 + n-chillers-ON OBJECT-TYPE + SYNTAX Integer32 (1..8) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "N chillers ON" + ::= { integerObjects 37 } + + -- 1.3.6.1.4.1.9839.2.1.3.38 + n-pumps-ON OBJECT-TYPE + SYNTAX Integer32 (1..8) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "N pumps ON" + ::= { integerObjects 38 } + + -- 1.3.6.1.4.1.9839.2.1.3.39 + time-Enable-Pumps-Chiller-Offline OBJECT-TYPE + SYNTAX Integer32 (0..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Time Enable Pumps - Chiller Offline" + ::= { integerObjects 39 } + + -- 1.3.6.1.4.1.9839.2.1.3.40 + time-Running-Pumps-Chiller-Offline OBJECT-TYPE + SYNTAX Integer32 (0..9999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Time Running Pumps - Chiller Offline" + ::= { integerObjects 40 } + + -- 1.3.6.1.4.1.9839.2.1.3.41 + integral-Time-3Way-Valve-Hydraulic-PID OBJECT-TYPE + SYNTAX Integer32 (0..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Integral Time 3Way Valve Hydraulic (PID)" + ::= { integerObjects 41 } + + -- 1.3.6.1.4.1.9839.2.1.3.42 + derivative-Time-3Way-Valve-Hydraulic-PID OBJECT-TYPE + SYNTAX Integer32 (0..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Derivative Time 3Way Valve Hydraulic (PID)" + ::= { integerObjects 42 } + + -- 1.3.6.1.4.1.9839.2.1.3.43 + output-Address-3Way-Valve-Hydraulic OBJECT-TYPE + SYNTAX Integer32 (0..6) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Output Address 3Way Valve Hydraulic" + ::= { integerObjects 43 } + + + -- 1.3.6.1.4.1.9839.2.1.3.44 + time-Speed-Up-FCM OBJECT-TYPE + SYNTAX Integer32 (0..99) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Time Speed-Up (FCM)" + ::= { integerObjects 44 } + + -- 1.3.6.1.4.1.9839.2.1.3.45 + time-Soft-Start-FCM OBJECT-TYPE + SYNTAX Integer32 (0..100) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Time Soft-Start (FCM)" + ::= { integerObjects 45 } + + + + + + -- 1.3.6.1.4.1.9839.2.1.3.47 + delay-Freecooling OBJECT-TYPE + SYNTAX Integer32 (0..9999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Delay Freecooling" + ::= { integerObjects 47 } + + -- 1.3.6.1.4.1.9839.2.1.3.48 + integral-Time-Freeccoling-PID OBJECT-TYPE + SYNTAX Integer32 (0..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Integral Time Freeccoling (PID)" + ::= { integerObjects 48 } + + -- 1.3.6.1.4.1.9839.2.1.3.49 + derivative-Time-Freeccoling-PID OBJECT-TYPE + SYNTAX Integer32 (0..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Derivative Time Freeccoling (PID)" + ::= { integerObjects 49 } + + -- 1.3.6.1.4.1.9839.2.1.3.50 + time-Min-On-Freecooling-Chiller-timing OBJECT-TYPE + SYNTAX Integer32 (0..32767) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Time Min. On (Freecooling - Chiller timing)" + ::= { integerObjects 50 } + + -- 1.3.6.1.4.1.9839.2.1.3.51 + time-Min-Off-Freecooling-Chiller-timing OBJECT-TYPE + SYNTAX Integer32 (0..32767) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Time Min. Off (Freecooling - Chiller timing)" + ::= { integerObjects 51 } + + -- 1.3.6.1.4.1.9839.2.1.3.52 + time-Min-Different-Freecooling-Chiller-timing OBJECT-TYPE + SYNTAX Integer32 (0..32767) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Time Min. Different (Freecooling - Chiller timing)" + ::= { integerObjects 52 } + + -- 1.3.6.1.4.1.9839.2.1.3.53 + time-Min-Same-Freecooling-Chiller-timing OBJECT-TYPE + SYNTAX Integer32 (0..32767) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Time Min. Same (Freecooling - Chiller timing)" + ::= { integerObjects 53 } + + -- 1.3.6.1.4.1.9839.2.1.3.54 + integral-Time-Freeccoling-Valve-PID OBJECT-TYPE + SYNTAX Integer32 (0..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Integral Time Freeccoling Valve (PID)" + ::= { integerObjects 54 } + + -- 1.3.6.1.4.1.9839.2.1.3.55 + derivative-Time-Freeccoling-Valve-PID OBJECT-TYPE + SYNTAX Integer32 (0..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Derivative Time Freeccoling Valve (PID)" + ::= { integerObjects 55 } + + + -- 1.3.6.1.4.1.9839.2.1.3.56 + output-Address-Valve-Freecooling OBJECT-TYPE + SYNTAX Integer32 (0..6) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Output Address Valve Freecooling" + ::= { integerObjects 56 } + + -- 1.3.6.1.4.1.9839.2.1.3.57 + delay-Freecooling-Thermal-Exclusion OBJECT-TYPE + SYNTAX Integer32 (0..999) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Delay Freecoolimg Thermal Exclusion" + ::= { integerObjects 57 } + + -- 1.3.6.1.4.1.9839.2.1.3.58 + n-of-alarm-External-Dry-Cooler OBJECT-TYPE + SYNTAX Integer32 (0..9) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "N of alarm (External Dry-Cooler)" + ::= { integerObjects 58 } + + + + + + -- 1.3.6.1.4.1.9839.2.1.3.59 + delay-Alarm-Static-Pressure OBJECT-TYPE + SYNTAX Integer32 (0..99) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Delay Alarm (Static Pressure)" + ::= { integerObjects 59 } + + -- 1.3.6.1.4.1.9839.2.1.3.60 + n-of-Alarm-Static-Pressure OBJECT-TYPE + SYNTAX Integer32 (1..10) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "N of Alarm (Static Pressure)" + ::= { integerObjects 60 } + + -- 1.3.6.1.4.1.9839.2.1.3.61 + delay-Warning-Static-Pressure OBJECT-TYPE + SYNTAX Integer32 (0..99) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Delay Warning (Static Pressure)" + ::= { integerObjects 61 } + + -- 1.3.6.1.4.1.9839.2.1.3.62 + n-of-Warning-Static-Pressure OBJECT-TYPE + SYNTAX Integer32 (1..10) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "N of Warning (Static Pressure)" + ::= { integerObjects 62 } + + -- 1.3.6.1.4.1.9839.2.1.3.63 + n-of-Alarm-Differential-Pressure OBJECT-TYPE + SYNTAX Integer32 (1..10) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "N of Alarm (Differential Pressure)" + ::= { integerObjects 63 } + + + -- 1.3.6.1.4.1.9839.2.1.3.64 + priming-Time-Hydraulic-Pressure OBJECT-TYPE + SYNTAX Integer32 (0..99) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Priming Time (Hydraulic Pressure)" + ::= { integerObjects 64 } + + -- 1.3.6.1.4.1.9839.2.1.3.65 + delay-priming-Time-Hydraulic-Pressure OBJECT-TYPE + SYNTAX Integer32 (0..99) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Delay Priming Time (Hydraulic Pressure)" + ::= { integerObjects 65 } + + -- 1.3.6.1.4.1.9839.2.1.3.66 + output-Address-Alarm-Static-Pressure OBJECT-TYPE + SYNTAX Integer32 (0..18) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Output Address Alarm (Static Pressure)" + ::= { integerObjects 66 } + + -- 1.3.6.1.4.1.9839.2.1.3.67 + n-of-Alarm-Flow-Rate OBJECT-TYPE + SYNTAX Integer32 (1..10) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "N of Alarm (Flow Rate)" + ::= { integerObjects 67 } + + + -- 1.3.6.1.4.1.9839.2.1.3.68 + priming-Time-Flow-Rate OBJECT-TYPE + SYNTAX Integer32 (0..99) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Priming Time (Flow Rate)" + ::= { integerObjects 68 } + + -- 1.3.6.1.4.1.9839.2.1.3.69 + delay-priming-Time-Flow-Rate OBJECT-TYPE + SYNTAX Integer32 (0..99) + UNITS "N/A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Delay Priming Time (Flow Rate)" + ::= { integerObjects 69 } + + + + + + -- 1.3.6.1.4.1.9839.2.1.3.70 + bms-address-IDENT OBJECT-TYPE + SYNTAX Integer32 (1..200) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "BMS address (IDENT)" + ::= { integerObjects 70 } + + + + + + + + + -- 1.3.6.1.4.1.9839.2.1.3.99 + chiller-name0 OBJECT-TYPE + SYNTAX Integer32 (0..9999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Chiller Model - Article Number - 0" + ::= { integerObjects 99 } + + + + -- 1.3.6.1.4.1.9839.2.1.3.100 + chiller-name1 OBJECT-TYPE + SYNTAX Integer32 (0..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Chiller Model - Article Number - 1" + ::= { integerObjects 100 } + + + + + + -- 1.3.6.1.4.1.9839.2.1.3.123 + current-day OBJECT-TYPE + SYNTAX Integer32 (1..31) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Day" + ::= { integerObjects 123 } + + -- 1.3.6.1.4.1.9839.2.1.3.124 + current-month OBJECT-TYPE + SYNTAX Integer32 (1..12) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Month" + ::= { integerObjects 124 } + + -- 1.3.6.1.4.1.9839.2.1.3.125 + current-year OBJECT-TYPE + SYNTAX Integer32 (0..99) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Year" + ::= { integerObjects 125 } + + -- 1.3.6.1.4.1.9839.2.1.3.126 + current-hour OBJECT-TYPE + SYNTAX Integer32 (0..23) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Hour" + ::= { integerObjects 126 } + + -- 1.3.6.1.4.1.9839.2.1.3.127 + current-minute OBJECT-TYPE + SYNTAX Integer32 (0..59) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Minute" + ::= { integerObjects 127 } + + + + -- 1.3.6.1.4.1.9839.2.1.3.150 + chiller-mode-operation OBJECT-TYPE + SYNTAX Integer32 (0..4) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Chiller mode operation" + ::= { integerObjects 150 } + + + +-- +-- Trap definitions +-- + + -- 1.3.6.1.4.1.9839.2.1.100 + trapObjects OBJECT IDENTIFIER ::= { kelvin-pCOWebMIB-Chiller 100 } + + + + + -- 1.3.6.1.4.1.9839.2.1.100.1 + high-pressure-switch-1-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "High pressure switch 1 alarm" + ::= { trapObjects 1 } + + -- 1.3.6.1.4.1.9839.2.1.100.2 + high-pressure-switch-2-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "High pressure switch 2 alarm" + ::= { trapObjects 2 } + + -- 1.3.6.1.4.1.9839.2.1.100.3 + low-pressure-switch-1-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Low pressure switch 1 alarm" + ::= { trapObjects 3 } + + -- 1.3.6.1.4.1.9839.2.1.100.4 + low-pressure-switch-2-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Low pressure switch 2 alarm" + ::= { trapObjects 4 } + + -- 1.3.6.1.4.1.9839.2.1.100.5 + --antifreeze-alarm NOTIFICATION-TYPE + -- STATUS current + -- DESCRIPTION "Antifreeze alarm" + -- ::= { trapObjects 5 } + + -- 1.3.6.1.4.1.9839.2.1.100.6 + water-level-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Water level alarm" + ::= { trapObjects 6 } + + -- 1.3.6.1.4.1.9839.2.1.100.7 + --digital-input-7 NOTIFICATION-TYPE + -- STATUS current + -- DESCRIPTION "Digital input 7" + -- ::= { trapObjects 7 } + + -- 1.3.6.1.4.1.9839.2.1.100.8 + flow-switch-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Flow switch alarm" + ::= { trapObjects 8 } + + -- 1.3.6.1.4.1.9839.2.1.100.9 + water-static-pressure-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Water static pressure alarm" + ::= { trapObjects 9 } + + -- 1.3.6.1.4.1.9839.2.1.100.10 + water-static-pressure-warning NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Water static pressure warning" + ::= { trapObjects 10 } + + -- 1.3.6.1.4.1.9839.2.1.100.11 + flow-rate-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Flow rate alarm" + ::= { trapObjects 11 } + + -- 1.3.6.1.4.1.9839.2.1.100.12 + overload-compressor1-circuit1-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Overload compressor 1 circuit 1 alarm" + ::= { trapObjects 12 } + + -- 1.3.6.1.4.1.9839.2.1.100.13 + overload-compressor2-circuit1-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Overload compressor 2 circuit 1 alarm" + ::= { trapObjects 13 } + + -- 1.3.6.1.4.1.9839.2.1.100.14 + overload-compressor3-circuit1-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Overload compressor 3 circuit 1 alarm" + ::= { trapObjects 14 } + + -- 1.3.6.1.4.1.9839.2.1.100.15 + overload-compressor1-circuit2-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Overload compressor 1 circuit 2 alarm" + ::= { trapObjects 15 } + + -- 1.3.6.1.4.1.9839.2.1.100.16 + overload-compressor2-circuit2-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Overload compressor 2 circuit 2 alarm" + ::= { trapObjects 16 } + + -- 1.3.6.1.4.1.9839.2.1.100.17 + overload-compressor3-circuit2-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Overload compressor 3 circuit 2 alarm" + ::= { trapObjects 17 } + + -- 1.3.6.1.4.1.9839.2.1.100.18 + overload-fans-circuit1 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Overload fans circuit 1" + ::= { trapObjects 18 } + + -- 1.3.6.1.4.1.9839.2.1.100.19 + overload-fans-circuit2 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Overload fans circuit 2" + ::= { trapObjects 19 } + + -- 1.3.6.1.4.1.9839.2.1.100.20 + overload-fan1-circuit1-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Overload fan 1 circuit 1 alarm" + ::= { trapObjects 20 } + + -- 1.3.6.1.4.1.9839.2.1.100.21 + overload-fan2-circuit1-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Overload fan 2 circuit 1 alarm" + ::= { trapObjects 21 } + + -- 1.3.6.1.4.1.9839.2.1.100.22 + overload-fan3-circuit1-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Overload fan 3 circuit 1 alarm" + ::= { trapObjects 22 } + + -- 1.3.6.1.4.1.9839.2.1.100.23 + overload-fan4-circuit1-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Overload fan 4 circuit 1 alarm" + ::= { trapObjects 23 } + + -- 1.3.6.1.4.1.9839.2.1.100.24 + overload-fan1-circuit-2-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Overload fan 1 circuit 2 alarm" + ::= { trapObjects 24 } + + -- 1.3.6.1.4.1.9839.2.1.100.25 + overload-fan2-circuit2-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Overload fan 2 circuit 2 alarm" + ::= { trapObjects 25 } + + -- 1.3.6.1.4.1.9839.2.1.100.26 + overload-fan3-circuit2-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Overload fan 3 circuit 2 alarm" + ::= { trapObjects 26 } + + -- 1.3.6.1.4.1.9839.2.1.100.27 + overload-fan4-circuit2-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Overload fan 4 circuit 2 alarm" + ::= { trapObjects 27 } + + -- 1.3.6.1.4.1.9839.2.1.100.28 + overload-pump1-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Overload pump 1 alarm" + ::= { trapObjects 28 } + + -- 1.3.6.1.4.1.9839.2.1.100.29 + overload-pump2-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Overload pump 2 alarm" + ::= { trapObjects 29 } + + -- 1.3.6.1.4.1.9839.2.1.100.30 + wrong-phase-rotation-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Wrong phase rotation alarm" + ::= { trapObjects 30 } + + -- 1.3.6.1.4.1.9839.2.1.100.31 + back-Door-open-alarm NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Back Door open alarm" + ::= { trapObjects 31 } + + + + --new index + + -- 1.3.6.1.4.1.9839.2.1.100.75 + alarm-idrofrigo-pump-c-1 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Condensation pump 1 breaker switch alarm" + ::= { trapObjects 75 } + + -- 1.3.6.1.4.1.9839.2.1.100.76 + alarm-idrofrigo-pump-c-2 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Condensation pump 2 breaker switch alarm" + ::= { trapObjects 76 } + + + -- 1.3.6.1.4.1.9839.2.1.100.80 + alarm-idrofrigo-fl-C NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Condensation flow switch alarm" + ::= { trapObjects 80 } + + --new index + + + + -- 1.3.6.1.4.1.9839.2.1.100.130 + remote-on-off NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Remote on-off" + ::= { trapObjects 130 } + + -- 1.3.6.1.4.1.9839.2.1.100.131 + chiller-ON-OFF NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Chiller ON/OFF" + ::= { trapObjects 131 } + + + + + --new index + + -- 1.3.6.1.4.1.9839.2.1.100.148 + alarm-disch-scw-1 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Discharge screw compressor 1 alarm" + ::= { trapObjects 148 } + + -- 1.3.6.1.4.1.9839.2.1.100.149 + alarm-disch-scw-2 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Discharge screw compressor 2 alarm" + ::= { trapObjects 149 } + + + -- 1.3.6.1.4.1.9839.2.1.100.150 + alarm-probe-inlet NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Inlet probe alarm (broken or disconnected)" + ::= { trapObjects 150 } + + + -- 1.3.6.1.4.1.9839.2.1.100.151 + alarm-probe-amb NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Ambient probe alarm (broken or disconnected)" + ::= { trapObjects 151 } + + + -- 1.3.6.1.4.1.9839.2.1.100.152 + alarm-frigo-fl1 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Flow switch alarm (cooling alarm)" + ::= { trapObjects 152 } + + + -- 1.3.6.1.4.1.9839.2.1.100.153 + alarm-idro-pump1 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Pump 1 hydraulic alarm" + ::= { trapObjects 153 } + + + -- 1.3.6.1.4.1.9839.2.1.100.154 + alarm-idro-pump2 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Pump 2 hydraulic alarm" + ::= { trapObjects 154 } + + + -- 1.3.6.1.4.1.9839.2.1.100.155 + alarm-idro-fl1 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Flow switch alarm (hydraulic alarm)" + ::= { trapObjects 155 } + + + -- 1.3.6.1.4.1.9839.2.1.100.156 + alarm-warning-fl1 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Flow switch alarm (warning alarm)" + ::= { trapObjects 156 } + + + -- 1.3.6.1.4.1.9839.2.1.100.157 + alarm-hi-water-temp NOTIFICATION-TYPE + STATUS current + DESCRIPTION "High Temperature alarm" + ::= { trapObjects 157 } + + + -- 1.3.6.1.4.1.9839.2.1.100.158 + alarm-lo-water-temp NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Low Temperature alarm" + ::= { trapObjects 158 } + + -- 1.3.6.1.4.1.9839.2.1.100.159 + alarm-ta-probe1 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Antifreeze/evaporator probe 1 alarm" + ::= { trapObjects 159 } + + + -- 1.3.6.1.4.1.9839.2.1.100.160 + alarm-hi-press NOTIFICATION-TYPE + STATUS current + DESCRIPTION "High condensation pressure alarm" + ::= { trapObjects 160 } + + -- 1.3.6.1.4.1.9839.2.1.100.161 + alarm-lo-press NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Low condensation pressure alarm" + ::= { trapObjects 161 } + + + -- 1.3.6.1.4.1.9839.2.1.100.162 + alarm-probe-evap-1 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Antifreeze/evaporator probe 1 alarm (broken or disconnected)" + ::= { trapObjects 162 } + + + -- 1.3.6.1.4.1.9839.2.1.100.163 + alarm-probe-evap-2 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Antifreeze/evaporator probe 2 alarm (broken or disconnected)" + ::= { trapObjects 163 } + + + -- 1.3.6.1.4.1.9839.2.1.100.164 + alarm-hi-press-1 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "High condensation pressure 1 alarm" + ::= { trapObjects 164 } + + + -- 1.3.6.1.4.1.9839.2.1.100.165 + alarm-hi-press-2 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "High condensation pressure 2 alarm" + ::= { trapObjects 165 } + + + -- 1.3.6.1.4.1.9839.2.1.100.166 + alarm-lo-press-1 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Low condensation pressure 1 alarm" + ::= { trapObjects 166 } + + + -- 1.3.6.1.4.1.9839.2.1.100.167 + alarm-lo-press-2 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Low condensation pressure 2 alarm" + ::= { trapObjects 167 } + + + -- 1.3.6.1.4.1.9839.2.1.100.168 + alarm-probe-tank NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Tank/Out probe alarm (broken or disconnected)" + ::= { trapObjects 168 } + + + -- 1.3.6.1.4.1.9839.2.1.100.169 + alarm-off-line-1 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Chiller 1 offline" + ::= { trapObjects 169 } + + -- 1.3.6.1.4.1.9839.2.1.100.170 + alarm-off-line-2 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Chiller 2 offline" + ::= { trapObjects 170 } + + -- 1.3.6.1.4.1.9839.2.1.100.171 + alarm-off-line-3 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Chiller 3 offline" + ::= { trapObjects 171 } + + -- 1.3.6.1.4.1.9839.2.1.100.172 + alarm-off-line-4 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Chiller 4 offline" + ::= { trapObjects 172 } + + -- 1.3.6.1.4.1.9839.2.1.100.173 + alarm-off-line-5 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Chiller 5 offline" + ::= { trapObjects 173 } + + + -- 1.3.6.1.4.1.9839.2.1.100.174 + alarm-off-line-6 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Chiller 6 offline" + ::= { trapObjects 174 } + + -- 1.3.6.1.4.1.9839.2.1.100.175 + alarm-off-line-7 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Chiller 7 offline" + ::= { trapObjects 175 } + + -- 1.3.6.1.4.1.9839.2.1.100.176 + alarm-off-line-8 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Chiller 8 offline" + ::= { trapObjects 176 } + + -- 1.3.6.1.4.1.9839.2.1.100.177 + alarm-ta-probe2 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Antifreeze/evaporator probe 2 alarm" + ::= { trapObjects 177 } + + + -- 1.3.6.1.4.1.9839.2.1.100.178 + alarm-sms NOTIFICATION-TYPE + STATUS current + DESCRIPTION "SMS alarm" + ::= { trapObjects 178 } + + + -- 1.3.6.1.4.1.9839.2.1.100.179 + alarm-modem NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Modem alarm" + ::= { trapObjects 179 } + + + -- 1.3.6.1.4.1.9839.2.1.100.180 + alarm-sms-coda NOTIFICATION-TYPE + STATUS current + DESCRIPTION "SMS coda alarm" + ::= { trapObjects 180 } + + + -- 1.3.6.1.4.1.9839.2.1.100.181 + alarm-probe-fc NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Freecooling probe alarm (broken or disconnected)" + ::= { trapObjects 181 } + + + -- 1.3.6.1.4.1.9839.2.1.100.182 + alarm-maint-pw1 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Maintenance pump 1 alarm)" + ::= { trapObjects 182 } + + -- 1.3.6.1.4.1.9839.2.1.100.183 + alarm-maint-pw2 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Maintenance pump 2 alarm)" + ::= { trapObjects 183 } + + + -- 1.3.6.1.4.1.9839.2.1.100.184 + alarm-hi-temp-rid NOTIFICATION-TYPE + STATUS current + DESCRIPTION "High temperature alarm (redundance)" + ::= { trapObjects 184 } + + -- 1.3.6.1.4.1.9839.2.1.100.185 + alarm-q-fc-sep NOTIFICATION-TYPE + STATUS current + DESCRIPTION "DryCooler breaker switch alarm" + ::= { trapObjects 185 } + + -- 1.3.6.1.4.1.9839.2.1.100.186 + alarm-p-wat2 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Water pressure 2 alarm" + ::= { trapObjects 186 } + + + -- 1.3.6.1.4.1.9839.2.1.100.187 + alarm-p-wat1 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Water pressure 1 alarm" + ::= { trapObjects 187 } + + + -- 1.3.6.1.4.1.9839.2.1.100.188 + alarm-foult-flow-p1 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Pump 1 flow alarm" + ::= { trapObjects 188 } + + + -- 1.3.6.1.4.1.9839.2.1.100.189 + alarm-foult-flow-p2 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Pump 2 flow alarm" + ::= { trapObjects 189 } + + -- 1.3.6.1.4.1.9839.2.1.100.190 + alarm-foult-fl1-p1 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Pump 1 flow-switch alarm" + ::= { trapObjects 190 } + + -- 1.3.6.1.4.1.9839.2.1.100.191 + alarm-foult-fl1-p2 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Pump 2 flow-switch alarm" + ::= { trapObjects 191 } + + -- 1.3.6.1.4.1.9839.2.1.100.192 + alarm-warning-le NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Water level warning" + ::= { trapObjects 192 } + + + -- 1.3.6.1.4.1.9839.2.1.100.193 + alarm-frigo-fl-C NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Flow switch condensation alarm (cooling alarm)" + ::= { trapObjects 193 } + + -- 1.3.6.1.4.1.9839.2.1.100.194 + alarm-idro-pump-c-1 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Pump 1 condensation hydraulic alarm" + ::= { trapObjects 194 } + + -- 1.3.6.1.4.1.9839.2.1.100.195 + alarm-idro-pump-c-2 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Pump 2 condensation hydraulic alarm" + ::= { trapObjects 195 } + + + -- 1.3.6.1.4.1.9839.2.1.100.196 + alarm-idro-fl-C NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Flow switch condensation alarm (hydraulic alarm)" + ::= { trapObjects 196 } + + -- 1.3.6.1.4.1.9839.2.1.100.197 + alarm-warning-fl-C NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Flow switch condensation alarm (warning alarm)" + ::= { trapObjects 197 } + + -- 1.3.6.1.4.1.9839.2.1.100.198 + alarm-foul-fl-C-p1 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Pump 1 condensation flow-switch alarm" + ::= { trapObjects 198 } + + -- 1.3.6.1.4.1.9839.2.1.100.199 + alarm-foul-fl-C-p2 NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Pump 2 condensation flow-switch alarm" + ::= { trapObjects 199 } + + + --new end + + END + +-- +-- kelvin-pCOWeb-Chiller.MIB +-- diff --git a/MIBS/carel/SCS-ks-MIB b/MIBS/carel/SCS-ks-MIB new file mode 100644 index 0000000..b7af805 --- /dev/null +++ b/MIBS/carel/SCS-ks-MIB @@ -0,0 +1,248 @@ +-- +-- SCS-ks.MIB +-- MIB generated by https://github.com/Torch09 +-- Thursday, 05 November 2020 +-- + + SCS-ks-MIB DEFINITIONS ::= BEGIN + + IMPORTS + OBJECT-GROUP + FROM SNMPv2-CONF + sysContact, sysName, sysLocation + FROM SNMPv2-MIB + enterprises, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32 + FROM SNMPv2-SMI + DisplayString + FROM RFC1213-MIB + enterprises, IpAddress, Counter, Gauge + FROM RFC1155-SMI + ifIndex, ifEntry + FROM IF-MIB; + + scs-ks MODULE-IDENTITY + LAST-UPDATED "202011051805Z" + ORGANIZATION "None" + CONTACT-INFO + " + None + GH: https://github.com/Torch09 + Mail: torch09gh@gmail.com + " + DESCRIPTION + "This is the unofficial MIB module for the SCS KS." + REVISION "202011051805Z" + DESCRIPTION "scs ks MIB" + + ::= { systm 1 } + + +-- +-- Node definitions +-- + + -- 1.3.6.1.4.1.9839 + carel OBJECT IDENTIFIER ::= { enterprises 9839 } + + -- 1.3.6.1.4.1.9839.1 + systm OBJECT IDENTIFIER ::= { carel 1 } + + -- 1.3.6.1.4.1.9839.1.2 + scs OBJECT IDENTIFIER ::= { systm 2 } + + + -- SCS VARIABLE + + -- 1.3.6.1.4.1.9839.1.2.1 + status-evaporator-fan OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Evaporator Fan alarm 0=OK;1=Error" + ::= { scs 1 } + + -- 1.3.6.1.4.1.9839.1.2.2 + status-condenser-fan OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Condenser Fan alarm 0=OK;1=Error" + ::= { scs 2 } + + -- 1.3.6.1.4.1.9839.1.2.3 + status-compressor OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Compressor alarm 0=OK;1=Error" + ::= { scs 3 } + + -- 1.3.6.1.4.1.9839.1.2.4 + status-heater-thermal-protection OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Heater thermal protection alarm 0=OK;1=Error" + ::= { scs 4 } + + -- 1.3.6.1.4.1.9839.1.2.5 + status-exhaust-air-sensor OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Exhaust air sensor alarm 0=OK;1=Error" + ::= { scs 5 } + + -- 1.3.6.1.4.1.9839.1.2.6 + status-supply-air-sensor OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Supply air sensor alarm 0=OK;1=Error" + ::= { scs 6 } + + -- 1.3.6.1.4.1.9839.1.2.7 + status-outside-sensor OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Outside temperature sensor alarm 0=OK;1=Error" + ::= { scs 7 } + + -- 1.3.6.1.4.1.9839.1.2.8 + status-room-temperature-sensor OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Temperature room sensor alarm 0=OK;1=Error" + ::= { scs 8 } + + -- 1.3.6.1.4.1.9839.1.2.9 + status-room-humidity-sensor OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Humidity room sensor alarm 0=OK;1=Error" + ::= { scs 9 } + + -- 1.3.6.1.4.1.9839.1.2.10 + status-min-exhaust-air-temperature OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Minimum exhaust air temperature alarm 0=OK;1=Error" + ::= { scs 10 } + + -- 1.3.6.1.4.1.9839.1.2.11 + status-max-exhaust-air-temperature OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Maximum exhaust air temperature alarm 0=OK;1=Error" + ::= { scs 11 } + + -- 1.3.6.1.4.1.9839.1.2.12 + status-min-supply-air-temperature OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Minimum supply air temperature alarm 0=OK;1=Error" + ::= { scs 12 } + + -- 1.3.6.1.4.1.9839.1.2.13 + status-water-sensor OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Water sensor alarm 0=OK;1=Error" + ::= { scs 13 } + + -- 1.3.6.1.4.1.9839.1.2.14 + status-filter-monitoring OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Filter monitoring alarm 0=OK;1=Error" + ::= { scs 14 } + + -- 1.3.6.1.4.1.9839.1.2.15 + exhaust-air-temperature OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Exhaust air temperature 235 = 23.5 degree Celsius" + ::= { scs 15 } + + -- 1.3.6.1.4.1.9839.1.2.16 + supply-air-temperature OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Supply air temperature 235 = 23.5 degree Celsius" + ::= { scs 16 } + + -- 1.3.6.1.4.1.9839.1.2.17 + outside-air-temperature OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Outside air temperature 235 = 23.5 degree Celsius" + ::= { scs 17 } + + -- 1.3.6.1.4.1.9839.1.2.18 + room-temperature OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Room temperature 235 = 23.5 degree Celsius" + ::= { scs 18 } + + -- 1.3.6.1.4.1.9839.1.2.19 + room-humidity OBJECT-TYPE + SYNTAX Integer32 (-999..999) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Room humidity 235 = 23.5 %" + ::= { scs 19 } + + -- 1.3.6.1.4.1.9839.1.2.20 + status-operational-status OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Operational status 0=Off;1=Running" + ::= { scs 20 } + + -- 1.3.6.1.4.1.9839.1.2.21 + status-collective-fault OBJECT-TYPE + SYNTAX Integer32 (0..1) + UNITS "N/A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Collective fault alarm 0=Error;1=Ok" + ::= { scs 21 } + END + +-- +-- SCS-ks.MIB +-- -- cgit v1.2.3