From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/dkt/IDKT-F2-MIB | 377 +++++++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 377 insertions(+) create mode 100644 MIBS/dkt/IDKT-F2-MIB (limited to 'MIBS/dkt/IDKT-F2-MIB') diff --git a/MIBS/dkt/IDKT-F2-MIB b/MIBS/dkt/IDKT-F2-MIB new file mode 100644 index 0000000..d8738c9 --- /dev/null +++ b/MIBS/dkt/IDKT-F2-MIB @@ -0,0 +1,377 @@ +IDKT-F2-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, Integer32, + Counter32 FROM SNMPv2-SMI + OBJECT-GROUP FROM SNMPv2-CONF + dkt FROM DKT-MIB + MacAddress FROM SNMPv2-TC; + +f2MIB MODULE-IDENTITY + LAST-UPDATED "201504210000Z" + ORGANIZATION "DKT A/S" + CONTACT-INFO + "postal: DKT A/S + Fanoevej 6 + DK-4060 Kirke Saaby + Denmark + + email: info@dktcomega.com" + DESCRIPTION "DKT 797xx series MIB." + ::= { dkt 15 } + +f2SwitchEngine OBJECT IDENTIFIER ::= { f2MIB 1 } + +f2IGMPSnooping OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Starts/stops IGMP snooping, input parameter 0 = stops IGMP snooping, 1 = starts IGMP snooping. Per Default IGMP snooping is disabled." + ::= { f2SwitchEngine 1 } + +f2MTU OBJECT-TYPE + SYNTAX INTEGER (0..8960) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Set and get MTU. The following values are valid: 3072, 4096, 6144, 8960 (3k, 4k, 6k and 8960 bytes)" + ::= { f2SwitchEngine 2 } + +f2FWDTable OBJECT-TYPE + SYNTAX SEQUENCE OF F2FWDMacAddressEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Get learned MAC addresses from LAN side of switch engine" + ::= { f2SwitchEngine 3 } + +f2FWDMacAddressEntry OBJECT-TYPE + SYNTAX F2FWDMacAddressEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Learned MAC address from LAN side of switch engine" + ::= { f2FWDTable 1 } + +F2FWDMacAddressEntry ::= SEQUENCE { + F2FWDMacAddress OCTET STRING +} + +F2FWDMacAddress OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "MAC address from LAN" + ::= { f2FWDMacAddressEntry 1 } + +f2Ports OBJECT IDENTIFIER ::= { f2MIB 2 } + +f2CPUPort OBJECT IDENTIFIER ::= { f2Ports 1 } + +f2CPUPortAutoNegotiation OBJECT-TYPE + SYNTAX INTEGER (0..10) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays auto negotiation state for the port." + ::= { f2CPUPort 1 } + +f2CPUPortSpeedMode OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(0..10)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the speed and duplex mode on the port." + ::= { f2CPUPort 2 } + + +f2CPUPortLinkStatus OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the Link status for the port" + ::= { f2CPUPort 3 } + + +f2CPUPortFlowControl OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control" + ::= { f2CPUPort 4 } + + +f2CPUPortEnable OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status for CPU port. Always 1 for enabled." + ::= { f2CPUPort 5 } + + +f2WANPort OBJECT IDENTIFIER ::= { f2Ports 2 } + +f2WANPortAutoNegotiation OBJECT-TYPE + SYNTAX INTEGER (0..10) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays auto negotiation state for the port." + ::= { f2WANPort 1 } + +f2WANPortSpeedMode OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(0..10)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)" + ::= { f2WANPort 2 } + + +f2WANPortLinkStatus OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the Link status for the port" + ::= { f2WANPort 3 } + + +f2WANPortFlowControl OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control" + ::= { f2WANPort 4 } + + +f2WANPortEnable OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status for WAN port. Always 1 for enabled." + ::= { f2WANPort 5 } + + + +f2LAN1Port OBJECT IDENTIFIER ::= { f2Ports 3 } + +f2LAN1PortAutoNegotiation OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays auto negotiation state for the port." + ::= { f2LAN1Port 1 } + +f2LAN1PortSpeedMode OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(0..10)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)" + ::= { f2LAN1Port 2 } + + +f2LAN1PortLinkStatus OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the Link status for the port" + ::= { f2LAN1Port 3 } + + +f2LAN1PortFlowControl OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control" + ::= { f2LAN1Port 4 } + + +f2LAN1PortEnable OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables/Disables LAN1 port. Set to 1 for Enabled set to 0 for Disabled." + ::= { f2LAN1Port 5 } + + + +f2LAN2Port OBJECT IDENTIFIER ::= { f2Ports 4 } + +f2LAN2PortAutoNegotiation OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays auto negotiation state for the port." + ::= { f2LAN2Port 1 } + +f2LAN2PortSpeedMode OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(0..10)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)" + ::= { f2LAN2Port 2 } + + +f2LAN2PortLinkStatus OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the Link status for the port" + ::= { f2LAN2Port 3 } + + +f2LAN2PortFlowControl OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control" + ::= { f2LAN2Port 4 } + + +f2LAN2PortEnable OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables/Disables LAN2 port. Set to 1 for Enabled set to 0 for Disabled." + ::= { f2LAN2Port 5 } + + + +f2LAN3Port OBJECT IDENTIFIER ::= { f2Ports 5 } + +f2LAN3PortAutoNegotiation OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays auto negotiation state for the port." + ::= { f2LAN3Port 1 } + +f2LAN3PortSpeedMode OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(0..10)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)" + ::= { f2LAN3Port 2 } + + +f2LAN3PortLinkStatus OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the Link status for the port" + ::= { f2LAN3Port 3 } + + +f2LAN3PortFlowControl OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control" + ::= { f2LAN3Port 4 } + + +f2LAN3PortEnable OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables/Disables LAN3 port. Set to 1 for Enabled set to 0 for Disabled." + ::= { f2LAN3Port 5 } + + +f2LAN4Port OBJECT IDENTIFIER ::= { f2Ports 6 } + +f2LAN4PortAutoNegotiation OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays auto negotiation state for the port." + ::= { f2LAN4Port 1 } + +f2LAN4PortSpeedMode OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(0..10)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)" + ::= { f2LAN4Port 2 } + + +f2LAN4PortLinkStatus OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the Link status for the port" + ::= { f2LAN4Port 3 } + + +f2LAN4PortFlowControl OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control" + ::= { f2LAN4Port 4 } + + +f2LAN4PortEnable OBJECT-TYPE + SYNTAX INTEGER (0..1) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables/Disables LAN4 port. Set to 1 for Enabled set to 0 for Disabled." + ::= { f2LAN4Port 5 } + + + + +f2ModuleGroup OBJECT-GROUP + OBJECTS { + f2SwitchEngine, + f2IGMPSnooping, + f2MTU, + f2Ports, + f2CPUPort, + f2CPUPortAutoNegotiation, f2CPUPortSpeedMode, f2CPUPortLinkStatus, f2CPUPortFlowControl, f2CPUPortEnable, + f2WANPort, + f2WANPortAutoNegotiation, f2WANPortSpeedMode, f2WANPortLinkStatus, f2WANPortFlowControl, f2WANPortEnable, + f2LAN1Port, + f2LAN1PortAutoNegotiation, f2LAN1PortSpeedMode, f2LAN1PortLinkStatus, f2LAN1PortFlowControl, f2LAN1PortEnable, + f2LAN2Port, + f2LAN2PortAutoNegotiation, f2LAN2PortSpeedMode, f2LAN2PortLinkStatus, f2LAN2PortFlowControl, f2LAN2PortEnable, + f2LAN3Port, + f2LAN3PortAutoNegotiation, f2LAN3PortSpeedMode, f2LAN3PortLinkStatus, f2LAN3PortFlowControl, f2LAN3PortEnable, + f2LAN4Port, + f2LAN4PortAutoNegotiation, f2LAN4PortSpeedMode, f2LAN4PortLinkStatus, f2LAN4PortFlowControl, f2LAN4PortEnable + } + STATUS current + DESCRIPTION + "The objects are related to the DKT 797xx series module, MIB rev 09." + ::= { f2MIB 3 } + + +END -- cgit v1.2.3