From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/eltek/ELTEK-BC2000-DC-POWER-MIB | 3795 ++++++++++++++++++++++++++++++++++ 1 file changed, 3795 insertions(+) create mode 100644 MIBS/eltek/ELTEK-BC2000-DC-POWER-MIB (limited to 'MIBS/eltek/ELTEK-BC2000-DC-POWER-MIB') diff --git a/MIBS/eltek/ELTEK-BC2000-DC-POWER-MIB b/MIBS/eltek/ELTEK-BC2000-DC-POWER-MIB new file mode 100644 index 0000000..4a68786 --- /dev/null +++ b/MIBS/eltek/ELTEK-BC2000-DC-POWER-MIB @@ -0,0 +1,3795 @@ +ELTEK-BC2000-DC-POWER-MIB DEFINITIONS ::= BEGIN + + IMPORTS + MODULE-IDENTITY + , OBJECT-TYPE + , NOTIFICATION-TYPE + , OBJECT-IDENTITY + , Counter32 + , Gauge32 + , Integer32 + , enterprises + , IpAddress + -- , Gauge + FROM SNMPv2-SMI + + Gauge + FROM RFC1155-SMI + + DisplayString + , TimeStamp +-- , TimeInterval +-- , TestAndIncr + , AutonomousType + , TEXTUAL-CONVENTION + FROM SNMPv2-TC + +-- MODULE-COMPLIANCE +-- , OBJECT-GROUP +-- FROM SNMPv2-CONF + +-- sysUpTime +-- FROM RFC1213-MIB + ; + + -- + -- date and time in UTC format YYYYMMDDHHmmZ + -- + eltek MODULE-IDENTITY + LAST-UPDATED "201403271038Z" + ORGANIZATION "Eltek Inc." + CONTACT-INFO + "Contact: Eltek Customer Support + Postal: 2925 E. Plano Pkwy + Plano, TX-75074 + Web: http://www.eltek.com + email: techsupport.us@eltek.com + Phone 800-435-4872 + " + DESCRIPTION + "SNMP access to Eltek DC Power systems through the BC2000 controller." + REVISION "201403271038Z" + DESCRIPTION + " Need History here. + MIB Version 2.10 + Final edits to PM (was TRIO) table (branch 17) + MIB Version 2.00 + Synchronized with new release + MIB Version 0.97 + Updated contact information + MIB Version 0.96 + Changed LVD Timers to read-only. Write not supported in this release + MIB Version 0.95 + Traps 70-72 added + Changed vpwrPMIndex variable to non negative integer + MIB Version 0.94 + Fixed module inventory process + Removed unused module test groups + Removed unused thermal probe entries + Changed vpwrBoostDuration from Hours to Seconds + New traps 63-69 added, trap 99 unknown added + Corrected Ringer present MIB + MIB Version 0.93 + Fixed spelling of vpwrBatteryCurrentCapacity + Fixed spelling of vpwrRingerAlarmAFailed + Fixed spelling of vpwrRingerAlarmBFailed + Fixed message with vpwrRingerAlarmBOverTemp + Fixed message with vpwrRingerAlarmBOverCurrent + Changed Centigrade to Celsius + Changed use of battety to battery throughout + Changed vpwrBDTDuration from 480 minutes to 1080 + Updated settable ringer parameters + Spelling corrections + MIB Version 0.92 + Fixed duplicate usage of vpwrTrapsMsgString + Fixed spelling of Gauge data type + MIB Version 0.91 + Version 2 Traps + MIB Version 0.9 + Sept 1, 06 + New Table- System Alarm History + New Table- for BDT Result History + New Table- for AVESTOR Battery + + New Traps - + Aux Alarm Source + Distribution Alarm Source + Battery Capacity Alarm + Battery Alarm Source + Battery SOC Trap + Battery SOH Trap + AC Fail Duration Trap + Battery Operational mode change + + MIB Version 0.8 + Add table to retrieve module inventory info + MIB Version 0.7 + Dec 1, 05 + Fixed HP Openview error + Fixed warnings generated by MG-SOFT + Add table to retrieve rectifier inventory info + MIB Version 0.6 + Feb 10, 2004 Added additional traps. + Defined Ringers and other modules. + Feb 08, 2003 Changed vpwrTrapDestinationTable to vpwrTrapTable + Corrected entry for vpwrTrapTable to be VpwrTrapTableEntry + This fixes errors generated by MG-SOFT mib compiler. + Oct 30, 2002 initial release - version 0.4 + " + + ::= {enterprises 13858} + +PositiveInteger ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d" + STATUS current + DESCRIPTION + "This data type is a non-zero and non-negative value." + SYNTAX Integer32 (1..2147483647) + +NonNegativeInteger ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d" + STATUS current + DESCRIPTION + "This data type is a non-negative value." + SYNTAX Integer32 (0..2147483647) + +GenericEnableDisableTC ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The defines how was BDT started." + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + +SysInputValue ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "These are the results of the system input value definitions." + SYNTAX INTEGER { + disabled(-127), + removed(-126), + shorted(-125), + auxAlarm(-124), + auxNormal(-123), + distAlarm(-122), + distNormal(-121), + undefined(255) + -- (0..127) + } + +-- BatteryOperModeTC ::= TEXTUAL-CONVENTION +-- STATUS current +-- DESCRIPTION +-- "The defines operational mode enumerations for the battery." +-- SYNTAX INTEGER { +-- batModeStandby (0), +-- batModeCharging(1), +-- batModeFloating(2), +-- batModeDischarging(3), +-- batModeNotAvailable(255) +-- } + +VpwrPMCnfgValue ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "These are the results of the system input value definitions." + SYNTAX INTEGER { + disabled(0), + tProbe(1), + auxNO(2), + auxNC(3), + distNO(4), + distNC(5), + undefined(255) + } + + +-- BatteryOperStatusTC ::= TEXTUAL-CONVENTION +-- STATUS current +-- DESCRIPTION +-- "The defines operational mode +-- enumerations for the battery." +-- SYNTAX INTEGER { +-- batStatusOk (0), +-- batStatusMinorFault(1), +-- batStatusMajorFault(2), +-- batStatusNotAvailable(255) +-- } + + +BDTStartSourceTC ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The defines how was BDT started." + SYNTAX INTEGER { + bdtInactive(0), + bdtManualStart(1), + bdtSched01Start1(2), + bdtSched02Start2(3), + bdtSched03Start3(4), + bdtSched04Start4(5), + bdtSched05Start5(6), + bdtSched06Start6(7), + bdtSched07Start7(8), + bdtSched08Start8(9), + bdtSched09Start9(10), + bdtSched10Start10(11), + bdtSched11Start11(12), + bdtSched12Start12(13), + bdtACFailStart(14) + } +BDTResultTC ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The defines how was BDT started." + SYNTAX INTEGER { + bdtResultCleared(0), + bdtResultPassed(1), + bdtResultFailed(2), + bdtResultStopped(3), + bdtResultAborted(4), + bdtResultInProgress(5) + } + + +-- vpwrDcPowerProducts OBJECT IDENTIFIER ::= { eltek 1 } + vpwrDcPowerSystem OBJECT IDENTIFIER ::= { eltek 2 } + vpwrDcPowerRectifier OBJECT IDENTIFIER ::= { eltek 3 } + vpwrDcPowerLvd OBJECT IDENTIFIER ::= { eltek 4 } +-- vpwrDcPowerTest OBJECT IDENTIFIER ::= { eltek 5 } + vpwrDcPowerModuleIdent OBJECT IDENTIFIER ::= { eltek 6 } + vpwrDcPowerBatteryGroup OBJECT IDENTIFIER ::= { eltek 7 } + vpwrDcPowerAlarmGroup OBJECT IDENTIFIER ::= { eltek 8 } + vpwrDcPowerSnmpConfig OBJECT IDENTIFIER ::= { eltek 9 } + vpwrDcPowerTraps OBJECT IDENTIFIER ::= { eltek 10 } + vpwrDcPowerTrapVars OBJECT IDENTIFIER ::= { eltek 11 } + + vpwrDcPowerRinger OBJECT IDENTIFIER ::= { eltek 12 } + vpwrDcPowerDcDcConverter OBJECT IDENTIFIER ::= { eltek 13 } + vpwrDcPowerDcAcInverter OBJECT IDENTIFIER ::= { eltek 14 } + vpwrDcPowerAcLineModule OBJECT IDENTIFIER ::= { eltek 15 } + vpwrDcPowerIoModule OBJECT IDENTIFIER ::= { eltek 16 } + + vpwrDcPowerPMModule OBJECT IDENTIFIER ::= { eltek 17 } + vpwrDcPowerDistModule OBJECT IDENTIFIER ::= { eltek 18 } + vpwrDcPowerBattery OBJECT IDENTIFIER ::= { eltek 19 } + vpwrDcPowerController OBJECT IDENTIFIER ::= { eltek 20 } + vpwrDcPowerUnkModule OBJECT IDENTIFIER ::= { eltek 499 } + thirdPartyProduct OBJECT IDENTIFIER ::= { eltek 500 } + +-- vpwrDcPowerTraps OBJECT IDENTIFIER ::= { vpwrDcPowerTrapsRoot 0 } + + vpwrSystemIdentGroup OBJECT IDENTIFIER ::= { vpwrDcPowerSystem 1 } + vpwrSystemConfigGroup OBJECT IDENTIFIER ::= { vpwrDcPowerSystem 2 } + vpwrSystemParameterGroup OBJECT IDENTIFIER ::= { vpwrDcPowerSystem 3 } + vpwrSystemPanelIdentGroup OBJECT IDENTIFIER ::= { vpwrDcPowerSystem 4 } + vpwrSystemHistoryGroup OBJECT IDENTIFIER ::= { vpwrDcPowerSystem 5 } + vpwrSystemAlarmGroup OBJECT IDENTIFIER ::= { vpwrDcPowerSystem 6 } + + vpwrLvdConfigGroup OBJECT IDENTIFIER ::= { vpwrDcPowerLvd 1 } +-- vpwrLvdAlarmGroup OBJECT IDENTIFIER ::= { vpwrDcPowerLvd 2 } +-- vpwrLvdTestGroup OBJECT IDENTIFIER ::= { vpwrDcPowerLvd 3 } + + vpwrRectifierConfigGroup OBJECT IDENTIFIER ::= { vpwrDcPowerRectifier 1 } + vpwrRectifierAlarmGroup OBJECT IDENTIFIER ::= { vpwrDcPowerRectifier 2 } +-- vpwrRectifierTestGroup OBJECT IDENTIFIER ::= { vpwrDcPowerRectifier 3 } + + vpwrBatteryTempGroup OBJECT IDENTIFIER ::= { vpwrDcPowerBatteryGroup 1 } + vpwrBatteryCurrentGroup OBJECT IDENTIFIER ::= { vpwrDcPowerBatteryGroup 2 } + vpwrBatteryBoostGroup OBJECT IDENTIFIER ::= { vpwrDcPowerBatteryGroup 3 } + vpwrBatteryDischargeTestGroup OBJECT IDENTIFIER ::= { vpwrDcPowerBatteryGroup 4 } + +-- vpwrTrapsMsgString OBJECT IDENTIFIER ::= { vpwrDcPowerTrapVars 1 } + + vpwrRingerConfigGroup OBJECT IDENTIFIER ::= { vpwrDcPowerRinger 1 } + vpwrRingerAlarmGroup OBJECT IDENTIFIER ::= { vpwrDcPowerRinger 2 } + vpwrRingerTestGroup OBJECT IDENTIFIER ::= { vpwrDcPowerRinger 3 } + + vpwrDcDcConverterConfigGroup OBJECT IDENTIFIER ::= { vpwrDcPowerDcDcConverter 1 } + vpwrDcDcConverterAlarmGroup OBJECT IDENTIFIER ::= { vpwrDcPowerDcDcConverter 2 } + vpwrDcDcConverterTestGroup OBJECT IDENTIFIER ::= { vpwrDcPowerDcDcConverter 3 } + + + vpwrDcAcInverterConfigGroup OBJECT IDENTIFIER ::= { vpwrDcPowerDcAcInverter 1 } + vpwrDcAcInverterAlarmGroup OBJECT IDENTIFIER ::= { vpwrDcPowerDcAcInverter 2 } + vpwrDcAcInverterTestGroup OBJECT IDENTIFIER ::= { vpwrDcPowerDcAcInverter 3 } + + vpwrAcLineModuleConfigGroup OBJECT IDENTIFIER ::= { vpwrDcPowerAcLineModule 1 } + vpwrAcLineModuleAlarmGroup OBJECT IDENTIFIER ::= { vpwrDcPowerAcLineModule 2 } + vpwrAcLineModuleTestGroup OBJECT IDENTIFIER ::= { vpwrDcPowerAcLineModule 3 } + + vpwrIoModuleConfigGroup OBJECT IDENTIFIER ::= { vpwrDcPowerIoModule 1 } + vpwrIoModuleAlarmGroup OBJECT IDENTIFIER ::= { vpwrDcPowerIoModule 2 } + vpwrIoModuleTestGroup OBJECT IDENTIFIER ::= { vpwrDcPowerIoModule 3 } + +-- vpwrTrioModuleConfigGroup OBJECT IDENTIFIER ::= { vpwrDcPowerTrioModule 1 } + vpwrPMModuleAlarmGroup OBJECT IDENTIFIER ::= { vpwrDcPowerPMModule 4 } + vpwrPMModuleTestGroup OBJECT IDENTIFIER ::= { vpwrDcPowerPMModule 5 } + +-- +-- PM variables +-- + +-- +-- Trap variables +-- + + vpwrTrapsMsgString OBJECT-TYPE + SYNTAX DisplayString(SIZE (0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " Place holder for trap notification message string" + ::= { vpwrDcPowerTrapVars 1 } + + vpwrTrapUserIpAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Place holder for IP address of the user accessing the system" + ::= { vpwrDcPowerTrapVars 2} + + vpwrTrapAcfDuration OBJECT-TYPE + SYNTAX NonNegativeInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Place holder for duration." + ::= { vpwrDcPowerTrapVars 3} + + vpwrAlarmingSubModuleBitMap OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "indices of alarming sources are encoded as a bit-map + e.g., + source 1 and source 2 will be encoded as hex 3. + source 1 and 3 will be encoded as hex 5. + " + ::= { vpwrDcPowerTrapVars 4 } + + vpwrBatteryCurrentCapacity OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " Place holder for total battery capacity" + ::= { vpwrDcPowerTrapVars 5 } + + vpwrAlarmingModuleIndex OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "index of alarming module. + " + ::= { vpwrDcPowerTrapVars 6 } + vpwrAlarmingModuleOID OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "It indicates the type of the module by specifiying its OID" + ::= { vpwrDcPowerTrapVars 7} + + vpwrAlarmingModuleBitMap OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "indices of alarming sources are encoded as a bit-map + e.g., + source 1 and source 2 will be encoded as hex 3. + source 1 and 3 will be encoded as hex 5. + " + ::= { vpwrDcPowerTrapVars 8 } + + vpwrBatteryRemainingTime OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " Place holder for remaining battery + time at the current load + " + ::= { vpwrDcPowerTrapVars 9 } + -- + -- The Identification group. + -- + + + vpwrIdentManufacturer OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..31)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of the DC Power manufacturer." + ::= { vpwrSystemIdentGroup 1 } + + + vpwrIdentModel OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..15)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The DC Power Model designation." + ::= { vpwrSystemIdentGroup 2 } + + vpwrIdentControllerVersion OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..15)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The hardware/firmware version(s). This variable + may or may not have the same value as + vpwrIdentAgentSoftwareVersion." + ::= { vpwrSystemIdentGroup 3 } + + vpwrIdentAgentSoftwareVersion OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..15)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The SNMP agent software version. This variable may or + may not have the same value as + vpwrIdentControllerVersion." + ::= { vpwrSystemIdentGroup 4 } + + vpwrIdentName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..31)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A string identifying the system. This object should be + set by the administrator." + ::= { vpwrSystemIdentGroup 5 } + + -- + -- The System Identifier group. + -- All objects in this group are read-only. It describes + -- various modules (rectifiers, converters, ringers, LVDs, etc.) that make up + -- the power system and are inserted into a shelf(.1) or panel(.2) + -- + vpwrSystemIdentTable OBJECT-TYPE + SYNTAX SEQUENCE OF VpwrSystemIdentEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " This table describes shelves and modules + that make up the sysetm. + " + ::= { vpwrSystemIdentGroup 6 } + + -- + -- The System Identifier Entry. Defines the sequence for module tables. + -- + vpwrSystemIdentEntry OBJECT-TYPE + SYNTAX VpwrSystemIdentEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing information applicable to a + particular alarm." + INDEX { vpwrBayIndex, vpwrModuleIndex } + ::= { vpwrSystemIdentTable 1 } + + + VpwrSystemIdentEntry ::= SEQUENCE { + vpwrBayIndex PositiveInteger, + vpwrModuleIndex PositiveInteger, + vpwrModuleOID OBJECT IDENTIFIER , + vpwrModuleCurrent INTEGER , + vpwrModuleOperStatus INTEGER , + vpwrModuleCapacity INTEGER + } + + -- + -- The System Shelf Identifier group. + -- + -- vpwrShelfIdentEntry OBJECT-TYPE + -- SYNTAX VpwrSystemIdentEntry + -- MAX-ACCESS not-accessible + -- STATUS current + -- DESCRIPTION + -- "An entry containing information applicable to a + -- particular module making up the system." + -- INDEX { vpwrBayIndex, vpwrModuleIndex } + -- ::= { vpwrSystemIdentTable 1 } + -- + vpwrBayIndex OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Identifies shelf number that this module belongs to. + The possible values are 1 through 16 limited by vpwrSystemShelfCapacity." + ::= { vpwrSystemIdentEntry 1 } + + vpwrModuleIndex OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object identifies the module by its position in the shelf. + Module numbering is left to right starting with module 1. So, the + module in the first slot has an index of 1, the next module is 2 and + so on." + ::= { vpwrSystemIdentEntry 2 } + + vpwrModuleOID OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "It indicates the type of the module by specifiying its OID" + ::= { vpwrSystemIdentEntry 3} + + vpwrModuleCurrent OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The meaning of this object depends upon the module type + which is indicated by vpwrModuleOID as follows + - Current for Rectifier module in centiamps. + - Not Applicable for LVD module + " + ::= { vpwrSystemIdentEntry 4} + + vpwrModuleOperStatus OBJECT-TYPE + SYNTAX INTEGER { + moduleStatusOK(0), + moduleStatusAlarm(1), + moduleStatusDisabled(2), + moduleStatusRingerAOn(3), + moduleStatusRingerBOn(4), + moduleStatusUnknown(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates current over all status of the module." + ::= { vpwrSystemIdentEntry 5} + + vpwrModuleCapacity OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The meaning of this object depends upon the module type + which is indicated by vpwrModuleOID as follows + - Capacity for Rectifier module. + - Not Applicable for LVD module + " + ::= { vpwrSystemIdentEntry 6} + + + + -- + -- The System Panel Identifier group. + -- + + vpwrPanelStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF VpwrPanelStatusEntrySEQ + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " This table describes shelves and modules + that make up the panels. + " + ::= { vpwrSystemPanelIdentGroup 1 } + + vpwrPanelStatus OBJECT-TYPE + SYNTAX VpwrPanelStatusEntrySEQ + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing information applicable to a + particular panel making up the system." + INDEX { vpwrPanelStatusIndex, vpwrPanelStatusModuleIndex } + ::= { vpwrPanelStatusTable 1 } + + VpwrPanelStatusEntrySEQ ::= SEQUENCE { + vpwrPanelStatusIndex PositiveInteger, + vpwrPanelStatusModuleIndex PositiveInteger, + vpwrPanelStatusModuleOID OBJECT IDENTIFIER , + vpwrPanelStatusModuleCurrent INTEGER , + vpwrpanelStatusModuleOperStatus INTEGER , + vpwrPanelStatusModuleCapacity INTEGER + } + + vpwrPanelStatusIndex OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Identifies panel number that this module belongs to. + The possible values are 1 through 8, starting from the top." + ::= { vpwrPanelStatus 1 } + + vpwrPanelStatusModuleIndex OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object identifies the module within the panel. + The orentation of modules within the panel is mappable." + ::= { vpwrPanelStatus 2 } + + vpwrPanelStatusModuleOID OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The module OID." + ::= { vpwrPanelStatus 3} + + vpwrPanelStatusModuleCurrent OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current measured by the device (if applicable). LVD current reported in deciAmps. + " + ::= { vpwrPanelStatus 4} + + vpwrpanelStatusModuleOperStatus OBJECT-TYPE + SYNTAX INTEGER { + moduleStatusOK(0), + moduleStatusAlarm(1), + moduleStatusDisabled(2), + moduleStatusRingerAOn(3), + moduleStatusRingerBOn(4), + moduleStatusUnknown(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates current over all status of the module." + ::= { vpwrPanelStatus 5} + + vpwrPanelStatusModuleCapacity OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum capacity of the module (if applicable)." + ::= { vpwrPanelStatus 6} + + + vpwrPanelIdentTable OBJECT-TYPE + SYNTAX SEQUENCE OF VpwrPanelIdentEntrySEQ + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " This table describes shelves and modules + that make up the panels. + " + ::= { vpwrSystemPanelIdentGroup 2 } + + + + vpwrPanelIdentEntry OBJECT-TYPE + SYNTAX VpwrPanelIdentEntrySEQ + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing information applicable to a + particular panel making up the system." + INDEX { vpwrPanelIndex, vpwrPanelModuleIndex } + ::= { vpwrPanelIdentTable 1 } + + + + + VpwrPanelIdentEntrySEQ ::= SEQUENCE { + vpwrPanelIndex PositiveInteger, + vpwrPanelModuleIndex PositiveInteger, + vpwrPanelModuleSerNum OBJECT IDENTIFIER , + vpwrPanelModuleModelName OBJECT IDENTIFIER , + vpwrPanelModuleFWVer OBJECT IDENTIFIER , + vpwrPanelModuleTestDate INTEGER + } + + vpwrPanelIndex OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Identifies panel number that this module belongs to. + The possible values are 1 through 8, starting from the top." + ::= { vpwrPanelIdentEntry 1 } + + vpwrPanelModuleIndex OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object identifies the module within the panel. + The orentation of modules within the panel is mappable." + ::= { vpwrPanelIdentEntry 2 } + + vpwrPanelModuleSerNum OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The module serial number." + ::= { vpwrPanelIdentEntry 3} + + vpwrPanelModuleModelName OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The model name of the device." + ::= { vpwrPanelIdentEntry 4} + + vpwrPanelModuleFWVer OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The module firmware version." + ::= { vpwrPanelIdentEntry 5} + + vpwrPanelModuleTestDate OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The manufacturing test date." + ::= { vpwrPanelIdentEntry 6} + +-- +-- Power Module inventory info +-- + vpwrDcPowerModuleIdentTable OBJECT-TYPE + SYNTAX SEQUENCE OF DCPowerModuleIdentEntrySEQ + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " This table describes power modules + that make up the system. + " + ::= { vpwrDcPowerModuleIdent 1 } + + -- + -- The Module Identifier Entry. Defines the sequence for module tables. + -- + + vpwrDcPowerModuleIdentEntry OBJECT-TYPE + SYNTAX DCPowerModuleIdentEntrySEQ + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing information applicable to a + power module." + INDEX { vpwrBayIndex1, vpwrDCModuleIndex } + ::= { vpwrDcPowerModuleIdentTable 1 } + + + DCPowerModuleIdentEntrySEQ ::= SEQUENCE { + vpwrBayIndex1 PositiveInteger, + vpwrDCModuleIndex PositiveInteger, + vpwrModuleSerialNumber DisplayString , + vpwrModuleModelNumber DisplayString , + vpwrModuleFwVersion DisplayString , + vpwrModuleTestDate DisplayString , + vpwrModuleOperHours Counter32 + } + + vpwrBayIndex1 OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Identifies shelf number that this module belongs to. + The possible values are 1 through 2, starting from the top." + ::= { vpwrDcPowerModuleIdentEntry 1 } + + vpwrDCModuleIndex OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object identifies the module within the shelf." + ::= { vpwrDcPowerModuleIdentEntry 2 } + + + vpwrModuleSerialNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Serial Number of the module" + ::= { vpwrDcPowerModuleIdentEntry 3} + + vpwrModuleModelNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Model Number of the module." + ::= { vpwrDcPowerModuleIdentEntry 4} + + vpwrModuleFwVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Firmware version of the module." + ::= { vpwrDcPowerModuleIdentEntry 5} + + vpwrModuleTestDate OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Date when the module was last tested." + ::= { vpwrDcPowerModuleIdentEntry 6} + + vpwrModuleOperHours OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Cumulative Operating Hours." + ::= { vpwrDcPowerModuleIdentEntry 7} + + + + +-- + -- + -- The System History group. + -- + vpwrSysHistAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF VpwrSysHistAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " This table provides a list of most recent alarms. + " + ::= { vpwrSystemHistoryGroup 1 } + + + vpwrSysHistAlarmEntry OBJECT-TYPE + SYNTAX VpwrSysHistAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry describing an alarm." + INDEX { vpwrSysHistAlarmIndex} + ::= { vpwrSysHistAlarmTable 1 } + + VpwrSysHistAlarmEntry ::= SEQUENCE { + vpwrSysHistAlarmIndex PositiveInteger, + vpwrSysHistAlarmDescription DisplayString + } + + vpwrSysHistAlarmIndex OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Alarm index." + ::= { vpwrSysHistAlarmEntry 1 } + + vpwrSysHistAlarmDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Alarm description including time stamp." + ::= { vpwrSysHistAlarmEntry 2 } + + + +-- +-- -- +--The System Configuration Parameters group. +-- -- + + vpwrSystemTempCompensation OBJECT-TYPE + SYNTAX INTEGER { + tempCompDisabled(0), + tempCompEnabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter enables/disables temperature compensation. + " + REFERENCE " " + + ::= {vpwrSystemConfigGroup 1} + + vpwrSystemTempCompStartTemperature OBJECT-TYPE + SYNTAX INTEGER (25..60) + UNITS "degrees Centigrade" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " The temperature at which temperature compensation becomes + active. + " + REFERENCE " " + ::= {vpwrSystemConfigGroup 2} + + vpwrSystemTempCompStopVoltage OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " When temperature compensation is active, vpwrSystemTempCompStopVoltage is the + limit to which float voltage will be reduced. + For example, to set this voltage to 51.75 volts enter a value of 5175. + " + REFERENCE " " + ::= {vpwrSystemConfigGroup 3} + + vpwrSystemTempCompensationSlope OBJECT-TYPE + SYNTAX INTEGER (0..250) + UNITS " milli-Volts per degrees Centigrade" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " The rate at which float voltage is changed, within the specified limits, + when temperature compensation is active. + " + REFERENCE " " + ::= {vpwrSystemConfigGroup 4} + + vpwrSystemThermalSenseType OBJECT-TYPE + SYNTAX INTEGER { + internal(0), + external(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter selects the temperature sensing point for temperature + compensation (in)activation. + " + REFERENCE " " + ::= {vpwrSystemConfigGroup 5} + + vpwrSystemHVAlarmSetpoint OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System High voltage alarm voltage setting. + " + ::= { vpwrSystemConfigGroup 6} + vpwrSystemBDAlarmSetpoint OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System Battery Discharge voltage setting." + ::= { vpwrSystemConfigGroup 7} + +-- +-- Threshold for Internal Temperature Trap +-- + vpwrSystemInternalTempLThreshold OBJECT-TYPE + SYNTAX INTEGER + UNITS "degrees Centigrade" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Temperature value at which temperature compensation inactive (clear) + trap would be sent if temperature compensation was active when this + value is reached. + " + ::= { vpwrSystemConfigGroup 8} + + vpwrSystemInternalTempUThreshold OBJECT-TYPE + SYNTAX INTEGER + UNITS "degrees Centigrade" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Temperature value at which temperature compensation active (set) trap + would be sent. + " + ::= { vpwrSystemConfigGroup 9} + + -- + -- The System Current Operating Parameters group. + -- + + + vpwrSystemShelfCapacity OBJECT-TYPE + SYNTAX INTEGER (1..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " It describes the maximum number of shelves that can/are controlled + by the controller. Each shelf is uniquely numbered in the range + from 1 to vpwrShelfCapacity. + " + REFERENCE " " + ::= {vpwrSystemParameterGroup 1} + + vpwrSystemVoltage OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " The current system voltage. + " + REFERENCE " " + ::= {vpwrSystemParameterGroup 2} + + vpwrSystemCurrent OBJECT-TYPE + SYNTAX INTEGER + UNITS " Amperes" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " The current system current. + " + REFERENCE " " + ::= {vpwrSystemParameterGroup 3} + + vpwrSystemControllerState OBJECT-TYPE + SYNTAX INTEGER { + systemControllerStateUnknown(0), + systemControllerStateNormal(1), + systemControllerStateChange(2) , + systemControllerStateAlarm(3), + systemControllerStateMenu(4 ), + systemControllerStateIrActive(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " Current System state as shown on the enhanced display. + " + REFERENCE " " + ::= {vpwrSystemParameterGroup 4} + + + vpwrSystemInternalTemperature OBJECT-TYPE + SYNTAX INTEGER + UNITS "degrees Centigrade" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " The current controller internal temperature. + " + REFERENCE " " + ::= {vpwrSystemParameterGroup 5} + + vpwrSystemTempCompensationState OBJECT-TYPE + SYNTAX INTEGER { + systemTempCompInactive(0), + systemTempCompActive(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " Active or Inactive. Applicable only if temperature compensation is enabled. + This means that the controller is temperature compensating the float voltage. + " + REFERENCE " " + ::= {vpwrSystemParameterGroup 6} + + vpwrSystemType OBJECT-TYPE + SYNTAX INTEGER { + sysType48V (0), + sysType24V(1) , + sysType12V(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This parameter describes the type of the system being managed. + This object is set by Eltek Valere Inc. + " + ::= { vpwrSystemParameterGroup 7 } + + vpwrSystemCumulativeUpTime OBJECT-TYPE + SYNTAX Gauge + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This parameter describes the cumulative runtime in seconds + of the Eltek Valere controller. + " + ::= { vpwrSystemParameterGroup 8 } + + vpwrSystemBatteryRemainingTime OBJECT-TYPE + SYNTAX PositiveInteger + UNITS "Hours" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This parameter describes the remaining battery capacity + based upon installed battery capacity and + plant load. This number would change as the SOC + parameters of the batteries changes. + " + ::= { vpwrSystemParameterGroup 9 } + + -- + -- The System Alarm group. + -- + + + vpwrSystemAlarmMajor OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " Indicates a Major Alarm exists on the system. + " + REFERENCE " " + ::= {vpwrSystemAlarmGroup 1} + + vpwrSystemAlarmMinor OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " Indicates a Minor Alarm exists on the system. + " + REFERENCE " " + ::= {vpwrSystemAlarmGroup 2} + + vpwrSystemACFailAlarm OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " One or more rectifiers have reported AC failure. If system + is configured to report rectifier communication failure as AC fail + this alarm will report. + " + REFERENCE " " + ::= {vpwrSystemAlarmGroup 3} + + vpwrSystemHighVoltageWarningAlarm OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " System has exceeded High Voltage Warning Setpoint. Check for high voltage on system bus. + " + REFERENCE " " + ::= {vpwrSystemAlarmGroup 4} + + + vpwrSystemHighVoltageShutdownAlarm OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " One or more rectifiers have shut down due to high voltage present on output. Check bus voltage + and reseat rectifiers that have indicated this problem. + " + REFERENCE " " + ::= {vpwrSystemAlarmGroup 5} + + vpwrSystemBatteryonDischargeAlarm OBJECT-TYPE + SYNTAX INTEGER { + systemTempCompInactive(0), + systemTempCompActive(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " System voltage has currently dropped below the alarm setpoint. This may be due to battery testing or AC failure. + " + REFERENCE " " + ::= {vpwrSystemAlarmGroup 6} + + vpwrSystemLowVoltageWarningAlarm OBJECT-TYPE + SYNTAX INTEGER { + sysType48V (0), + sysType24V(1) , + sysType12V(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "System Voltage has dropped below setpoint for Low Voltage Alarm. This may occur during battery testing or AC failure + " + ::= { vpwrSystemAlarmGroup 7 } + + vpwrSystemLVDOpenAlarm OBJECT-TYPE + SYNTAX Gauge + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "One or more contactors have opened. This occurs normally during system power on. If it occurs during operation this may + indicate system is operating below LVD disconnect voltage. + " + ::= { vpwrSystemAlarmGroup 8 } + + vpwrSystemDistributionAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "One or more distribution alarm inputs are reporting an error condition. Check source of alarm and correct issue. + " + ::= { vpwrSystemAlarmGroup 9 } + + vpwrSystemAuxiliaryAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "One or more Auxliary alarm inputs are reporting an error condition. Check source of alarm and correct issue. + " + ::= { vpwrSystemAlarmGroup 10 } + + vpwrSystemRedundantCapAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The system load has exceeded the requirements for redundancy. This may be a temporary system overload condition or caused by a rectifier alarm. + " + ::= { vpwrSystemAlarmGroup 11 } + + vpwrSystemRectIShareAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "One or more rectifiers are reporting a mismatch in current. This may be due to mismatched rectifier models or one or more rectifiers not current sharing + " + ::= { vpwrSystemAlarmGroup 12 } + + vpwrSystemSnglRectAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + " + ::= { vpwrSystemAlarmGroup 13 } + + vpwrSystemMultRectAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + " + ::= { vpwrSystemAlarmGroup 14 } + + vpwrSystemModlCommAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + " + ::= { vpwrSystemAlarmGroup 15 } + + vpwrSystemOverTempAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + " + ::= { vpwrSystemAlarmGroup 16 } + + vpwrSystemThermRAAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Thermal Runaway has occurred on system. Check temperature inputs. + " + ::= { vpwrSystemAlarmGroup 17 } + + vpwrSystemBDTAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "System has entered Battery Discharge Test mode + " + ::= { vpwrSystemAlarmGroup 18 } + + vpwrSystemRectUVAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Rectifier output has dropped 1V below Low Voltage Alarm setpoint + " + ::= { vpwrSystemAlarmGroup 19 } + + vpwrSystemMultRectUVAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + " + ::= { vpwrSystemAlarmGroup 20 } + + vpwrSystemSnglRngrAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + " + ::= { vpwrSystemAlarmGroup 21 } + + vpwrSystemMultRngrAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + " + ::= { vpwrSystemAlarmGroup 22 } + + vpwrSystemTempProbeAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Temp probe input missing or failed + " + ::= { vpwrSystemAlarmGroup 23 } + + vpwrSystemRngrCommAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ringer Module has stopped communicating with Controller. + " + ::= { vpwrSystemAlarmGroup 24 } + + vpwrSystemDistPMCommAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "One or more distribution alarm modules, TRIOs, or PM modules has stopped communicating with Controller. + " + ::= { vpwrSystemAlarmGroup 25 } + + vpwrSystemRectILimitAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Rectifier has reached current limit setpoint. + " + ::= { vpwrSystemAlarmGroup 26 } + + vpwrSystemMultRectILimitAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + " + ::= { vpwrSystemAlarmGroup 27 } + + vpwrSystemUnmappedI2CCANAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Recheck all I2C and CAN dip switch settings. One or more devices in conflict. + " + ::= { vpwrSystemAlarmGroup 28 } + + vpwrSystemConfigErrAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Recheck all I2C and CAN dip switch settings. One or more devices in conflict. + " + ::= { vpwrSystemAlarmGroup 29 } + + vpwrSystemDispFWAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + " + ::= { vpwrSystemAlarmGroup 30 } + + vpwrSystemUndefinedAlarm OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " + " + ::= { vpwrSystemAlarmGroup 31 } + + -- vpwrSystemModlCommAlarm OBJECT-TYPE + -- SYNTAX PositiveInteger + -- MAX-ACCESS read-only + -- STATUS current + -- DESCRIPTION + -- " + -- " + -- ::= { vpwrSystemAlarmGroup 32 } + + -- + -- The System LVD Operating Setpoints group. + -- + + vpwrLvdWarningSetpoint OBJECT-TYPE + SYNTAX INTEGER + UNITS " * .01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "LVD Warning voltage setpoint." + ::= { vpwrLvdConfigGroup 1} + + vpwrLvdDisconnectSetpoint OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "LVD disconnect voltage setpoint." + ::= { vpwrLvdConfigGroup 2} + vpwrLvdReconnectSetpoint OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "LVD Reconnect voltage setpoint." + ::= { vpwrLvdConfigGroup 3} + vpwrLvdReconnectDelayTimer OBJECT-TYPE + SYNTAX INTEGER (20..240) + UNITS " Seconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The delay time, in seconds, before LVD is reconnected" + ::= { vpwrLvdConfigGroup 4} + -- + -- The System LVD Operating Setpoints group. + -- + + vpwrLvd2DisconnectSetpoint OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "LVD disconnect voltage setpoint." + ::= { vpwrLvdConfigGroup 7} + vpwrLvd2ReconnectSetpoint OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "LVD Reconnect voltage setpoint." + ::= { vpwrLvdConfigGroup 8} + vpwrLvd2ReconnectDelayTimer OBJECT-TYPE + SYNTAX INTEGER (20..240) + UNITS " Seconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The delay time, in seconds, before LVD is reconnected" + ::= { vpwrLvdConfigGroup 9} + + + -- + -- The System LVD Operating Setpoints group. + -- + + vpwrLvd3DisconnectSetpoint OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "LVD disconnect voltage setpoint." + ::= { vpwrLvdConfigGroup 11} + vpwrLvd3ReconnectSetpoint OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "LVD Reconnect voltage setpoint." + ::= { vpwrLvdConfigGroup 12} + vpwrLvd3ReconnectDelayTimer OBJECT-TYPE + SYNTAX INTEGER (20..240) + UNITS " Seconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The delay time, in seconds, before LVD is reconnected" + ::= { vpwrLvdConfigGroup 13} + + -- + -- The System LVD Operating Setpoints group. + -- + + + vpwrLvd4DisconnectSetpoint OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "LVD disconnect voltage setpoint." + ::= { vpwrLvdConfigGroup 15} + vpwrLvd4ReconnectSetpoint OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "LVD Reconnect voltage setpoint." + ::= { vpwrLvdConfigGroup 16} + vpwrLvd4ReconnectDelayTimer OBJECT-TYPE + SYNTAX INTEGER (20..240) + UNITS " Seconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The delay time, in seconds, before LVD is reconnected" + ::= { vpwrLvdConfigGroup 17} + +-- vpwrLvd4DisconnectDelayTimer OBJECT-TYPE +-- SYNTAX INTEGER (20..240) +-- UNITS " Seconds" +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- "The delay time, in seconds, before LVD is reconnected" +-- ::= { vpwrLvdConfigGroup 18} + -- + -- The Rectifier Operating Parameters group. + -- + + vpwrRectifierFVSetpoint OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System Float Voltage setting" + ::= { vpwrRectifierConfigGroup 1} + vpwrRectifierHVSDSetpoint OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "System High Voltage Shutdown voltage setting" + ::= { vpwrRectifierConfigGroup 2} + + vpwrRectifierCurrentLimitAdminState OBJECT-TYPE + SYNTAX INTEGER { + rectCurrentLimitDisabled(0), + rectCurrentLimitEnabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter allows enabling or rectifier current limit" + REFERENCE " " + + ::= {vpwrRectifierConfigGroup 3} + + vpwrRectifierCurrentLimit OBJECT-TYPE + SYNTAX INTEGER (5..220) + UNITS "Amperes" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Rectifier current limit setpoint" + ::= { vpwrRectifierConfigGroup 4} + + vpwrRectifierFallbackAdminState OBJECT-TYPE + SYNTAX GenericEnableDisableTC + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables Rectifier to use + Fallback Voltage when it loses + communication with the controller. + This applies to all rectifiers." + ::= { vpwrRectifierConfigGroup 5} + + vpwrRectifierFallbackVoltage OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fallback Voltage setpoint to use + when rectifier loses + communication with the controller. + This applies to all rectifiers." + ::= { vpwrRectifierConfigGroup 6} + + -- + -- The Alarm group. + -- + + + vpwrAlarmsPresent OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The present number of active alarm conditions." + ::= { vpwrDcPowerAlarmGroup 1 } + + vpwrAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF VpwrAlarmEntrySEQ + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of alarm table entries. The table contains + zero, one, or multiple rows at any time depending upon + the number of alarm conditions in effect. The table + is initially empty at agent startup. The agent + creates a row in the table each time a condition is + detected and deletes that row when that condition no + longer exists. + The vpwrAlarmIndex, for each type of module starts at 1 + and is limited by the total number of alarms that can be + generated by the module. + + Alarms are named by an AutonomousType (OBJECT + IDENTIFIER), vpwrAlarmDescr, to allow a single table to + reflect alarms for different types of modules. + + The number of rows in the table at any given time is + reflected by the value of vpwrAlarmsPresent." + + ::= { vpwrDcPowerAlarmGroup 2 } + + vpwrAlarmEntry OBJECT-TYPE + SYNTAX VpwrAlarmEntrySEQ + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing information applicable to a + particular alarm." + INDEX { vpwrBayIndex, vpwrModuleIndex, vpwrAlarmIndex } + ::= { vpwrAlarmTable 1 } + + VpwrAlarmEntrySEQ ::= SEQUENCE { + vpwrAlarmIndex PositiveInteger, + vpwrAlarmDescr AutonomousType, + vpwrAlarmTime TimeStamp + } + + vpwrAlarmIndex OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Identifies the alarm associated with the module. + It is unique on per module type basis. For example, + multiple rectifiers can have the same alarm and therefore same + vpwrAlarmIndex active at any one time. + " + ::= { vpwrAlarmEntry 1 } + + + vpwrAlarmDescr OBJECT-TYPE + SYNTAX AutonomousType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A reference to an alarm description object. The + object referenced should not be accessible, but rather + be used to provide a unique description of the alarm + condition." + ::= { vpwrAlarmEntry 2 } + + vpwrAlarmTime OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime when the alarm condition was + detected." + + ::= { vpwrAlarmEntry 3 } + + + + -- + -- The Battery Group + -- + + + + vpwrBatteryTempTable OBJECT-TYPE + SYNTAX SEQUENCE OF VpwrBatteryTempEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table describes battery temperature probes. + " + ::= { vpwrBatteryTempGroup 1 } + + vpwrBatteryTempEntry OBJECT-TYPE + SYNTAX VpwrBatteryTempEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing information applicable to a + particular temperature probe." + INDEX { vpwrBatteryTempIndex } + ::= { vpwrBatteryTempTable 1 } + + VpwrBatteryTempEntry ::= SEQUENCE { + vpwrBatteryTempIndex INTEGER, + vpwrBatteryTempName DisplayString, + vpwrBatteryTemp SysInputValue + } + + vpwrBatteryTempIndex OBJECT-TYPE + SYNTAX INTEGER (0..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index into temperature table" + ::= { vpwrBatteryTempEntry 1} + + vpwrBatteryTempName OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..8)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A string identifying probe location." + ::= { vpwrBatteryTempEntry 2} + + vpwrBatteryTemp OBJECT-TYPE + SYNTAX SysInputValue + UNITS "degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current temperature as recorded by the probe." + ::= { vpwrBatteryTempEntry 3} + + +-- Threshold for Battery Temperature Trap + + vpwrBatteryTempLThreshold OBJECT-TYPE + SYNTAX INTEGER + UNITS "degrees Celsius" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Temperature value at which a clear trap would be sent. + All three battery temperature must be at or below this value + to trigger this trap. + " + ::= { vpwrBatteryTempGroup 2} + + vpwrBatteryTempUThreshold OBJECT-TYPE + SYNTAX INTEGER + UNITS "degrees Celsius" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Temperature value at which a set trap would be sent. + Any one of the three battery temperatures at or exceeding this limit + would trigger the trap. + " + ::= { vpwrBatteryTempGroup 3} + + batteryTempCompensation OBJECT-TYPE + SYNTAX INTEGER { + tempCompDisabled(0), + tempCompEnabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter enables/disables temperature compensation. + " + REFERENCE " " + + ::= {vpwrBatteryTempGroup 4} + + batteryTempCompHighStartTemperature OBJECT-TYPE + SYNTAX INTEGER (25..60) + UNITS "degrees Celsius" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " The temperature at which temperature compensation becomes + active. + " + REFERENCE " " + ::= {vpwrBatteryTempGroup 5} + + batteryTempCompHighStopVoltage OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " When temperature compensation is active, batteryTempCompHighStopVoltage is the + limit to which float voltage will be reduced. + For example, to set this voltage to 51.75 volts enter a value of 5175. + " + REFERENCE " " + ::= {vpwrBatteryTempGroup 6} + + batteryTempCompHighSlope OBJECT-TYPE + SYNTAX INTEGER (0..250) + UNITS " milli-Volts per degrees Celsius" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " The rate at which float voltage is changed, within the specified limits, + when temperature compensation is active. + " + REFERENCE " " + ::= {vpwrBatteryTempGroup 7} + + + batteryTempCompLowStartTemperature OBJECT-TYPE + SYNTAX INTEGER + UNITS "degrees Celsius" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " The temperature at which temperature compensation becomes + active. + " + REFERENCE " " + ::= {vpwrBatteryTempGroup 8} + + batteryTempCompLowStopVoltage OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " When temperature compensation is active, batteryTempCompLowStopVoltage is the + limit to which float voltage will be reduced. + For example, to set this voltage to 51.75 volts enter a value of 5175. + " + REFERENCE " " + ::= {vpwrBatteryTempGroup 9} + + batteryTempCompLowSlope OBJECT-TYPE + SYNTAX INTEGER (0..250) + UNITS " milli-Volts per degrees Celsius" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " The rate at which float voltage is changed, within the specified limits, + when temperature compensation is active. + " + REFERENCE " " + ::= {vpwrBatteryTempGroup 10} + + batteryTempCompRunawayTemperature OBJECT-TYPE + SYNTAX INTEGER (25..60) + UNITS "degrees Celsius" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " The temperature at which system voltage will be set to + batteryTempCompRunawayStopVoltage. + " + REFERENCE " " + ::= {vpwrBatteryTempGroup 11} + + batteryTempCompRunawayStopVoltage OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " When temperature compensation is enabled, float voltage will be reduced to + batteryTempCompRunawayStopVoltage if temperature + reaches batteryTempCompRunawayTemperature. + " + REFERENCE " " + ::= {vpwrBatteryTempGroup 12} + + batteryTempCompSenseSource OBJECT-TYPE + SYNTAX INTEGER { + internal(0), + external(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter selects the temperature sensing point for temperature + compensation (in)activation. + " + REFERENCE " " + ::= {vpwrBatteryTempGroup 13} + + batteryTempCompRunawayState OBJECT-TYPE + SYNTAX INTEGER { + inactive(0), + active(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " This parameter selects the temperature sensing point for temperature + compensation (in)activation. + " + REFERENCE " " + ::= {vpwrBatteryTempGroup 14} + +-- thermalProbeTable OBJECT-TYPE +-- SYNTAX SEQUENCE OF ThermalProbeEntry +-- MAX-ACCESS not-accessible +-- STATUS current +-- DESCRIPTION +-- "This table describes battery temperature probes. +-- " +-- ::= { vpwrBatteryTempGroup 15 } +-- +-- thermalProbeEntry OBJECT-TYPE +-- SYNTAX ThermalProbeEntry +-- MAX-ACCESS not-accessible +-- STATUS current +-- DESCRIPTION +-- "An entry containing information applicable to a +-- particular temperature probe." +-- INDEX { vpwrBatteryTempIndex } +-- AUGMENTS {vpwrBatteryTempEntry} +-- ::= { thermalProbeTable 1 } +-- +-- ThermalProbeEntry ::= SEQUENCE { +-- thermalProbeState INTEGER +-- } +-- +-- thermalProbeState OBJECT-TYPE +-- SYNTAX INTEGER { +-- notPresent(0), +-- present(1), +-- removed(2), +-- shorted(3) +-- } +-- MAX-ACCESS read-only +-- STATUS current +-- DESCRIPTION +-- "State of thermal probe." +-- ::= { thermalProbeEntry 1} + + +-- +-- The SNMP Configuration Parameters +-- + + vpwrTrapTable OBJECT-TYPE + SYNTAX SEQUENCE OF VpwrTrapEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of possible trap destinations depending upon + the criticality of the trap. + " + ::= { vpwrDcPowerSnmpConfig 1 } + + vpwrTrapEntry OBJECT-TYPE + SYNTAX VpwrTrapEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing information applicable to a + particular trap destination." + INDEX { vpwrTrapIpIndex } + ::= { vpwrTrapTable 1 } + + VpwrTrapEntry ::= SEQUENCE { + vpwrTrapIpIndex INTEGER, + vpwrTrapIpAddress IpAddress, + vpwrTrapCriticality INTEGER + } + vpwrTrapIpIndex OBJECT-TYPE + SYNTAX INTEGER (0..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Trap Entry Index " + ::= { vpwrTrapEntry 1} + + vpwrTrapIpAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Trap destination IP Address" + ::= { vpwrTrapEntry 2} + + vpwrTrapCriticality OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Criticality of traps sent to this IP Address" + ::= { vpwrTrapEntry 3} + + + vpwrReadCommunityString OBJECT-TYPE + SYNTAX DisplayString(SIZE (3..8)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This allows setting password to be able to do Get operations" + ::= { vpwrDcPowerSnmpConfig 2 } + + vpwrWriteCommunityString OBJECT-TYPE + SYNTAX DisplayString(SIZE (3..8)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This allows setting password to be able to do Get and Set + operations. + The read-access is not allowed in the actual implementation. + " + ::= { vpwrDcPowerSnmpConfig 3 } + + vpwrTrapCommunityString OBJECT-TYPE + SYNTAX DisplayString(SIZE (3..8)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This allows setting community string required for the + trap to be accepted at the destination. + " + ::= { vpwrDcPowerSnmpConfig 4 } + + vpwrTrapVersion OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This allows setting the version of trap message sent from the system" + ::= { vpwrDcPowerSnmpConfig 5 } + + + +-- +-- LVD Alarm Group +-- + +-- vpwrLvdAlarmContactorOpen OBJECT-IDENTITY +-- STATUS current +-- DESCRIPTION +-- "Contactor open" +-- ::= {vpwrLvdAlarmGroup 1 } + + +-- vpwrLvdAlarmCBOpen OBJECT-IDENTITY +-- STATUS current +-- DESCRIPTION +-- "Circuit Breaker open" +-- ::= {vpwrLvdAlarmGroup 2 } + +-- vpwrTrapLvdFuseOpen OBJECT-IDENTITY +-- STATUS current +-- DESCRIPTION +-- "Fuse open" +-- ::= {vpwrLvdAlarmGroup 3 } + +-- vpwrLvdAlarmWarning OBJECT-IDENTITY +-- STATUS current +-- DESCRIPTION +-- "Plant Voltage below warning threshold" +-- ::= {vpwrLvdAlarmGroup 4 } + +-- +-- Rectifier Alarm Group +-- + + vpwrRectAlarmDCFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + " + " + ::= {vpwrRectifierAlarmGroup 1} + + vpwrRectAlarmBoostFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + " + " + ::= {vpwrRectifierAlarmGroup 2} + + vpwrRectAlarmACFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + " + " + ::= {vpwrRectifierAlarmGroup 3} + + vpwrRectAlarmHVSD OBJECT-IDENTITY + STATUS current + DESCRIPTION + " + " + ::= {vpwrRectifierAlarmGroup 4} + + vpwrRectAlarmFanFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + " + " + ::= {vpwrRectifierAlarmGroup 5} + + vpwrRectAlarmAmbTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + " + " + ::= {vpwrRectifierAlarmGroup 6} + vpwrRectAlarmIntTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + " + " + ::= {vpwrRectifierAlarmGroup 7} + + vpwrRectAlarmIShare OBJECT-IDENTITY + STATUS current + DESCRIPTION + " + " + ::= {vpwrRectifierAlarmGroup 8} + + vpwrRectAlarmUV OBJECT-IDENTITY + STATUS current + DESCRIPTION + " + " + ::= {vpwrRectifierAlarmGroup 9} + + vpwrRectAlarmLowVoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + " + " + ::= {vpwrRectifierAlarmGroup 10} + + vpwrRectAlarmReserved OBJECT-IDENTITY + STATUS current + DESCRIPTION + " + " + ::= {vpwrRectifierAlarmGroup 11} + + vpwrRectAlarmDCEnable OBJECT-IDENTITY + STATUS current + DESCRIPTION + " + " + ::= {vpwrRectifierAlarmGroup 12} + + vpwrRectAlarmRemoteShutdown OBJECT-IDENTITY + STATUS current + DESCRIPTION + " + " + ::= {vpwrRectifierAlarmGroup 13} + + vpwrRectAlarmModDisableShutdown OBJECT-IDENTITY + STATUS current + DESCRIPTION + " + " + ::= {vpwrRectifierAlarmGroup 14} + + vpwrRectAlarmShortPinShutdown OBJECT-IDENTITY + STATUS current + DESCRIPTION + " + " + ::= {vpwrRectifierAlarmGroup 15} + + vpwrRectAlarmBoostComm OBJECT-IDENTITY + STATUS current + DESCRIPTION + " + " + ::= {vpwrRectifierAlarmGroup 16} + + + + + + sysAlarmConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF SysAlarmConfigEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table describes system alarm configuration and current + status. + " + ::= { vpwrDcPowerAlarmGroup 3 } + + sysAlarmConfigEntry OBJECT-TYPE + SYNTAX SysAlarmConfigEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing information applicable to a + particular system alarm." + INDEX { sysAlarmIndex } + ::= { sysAlarmConfigTable 1 } + + SysAlarmConfigEntry ::= SEQUENCE { + sysAlarmIndex INTEGER, + sysAlarmDefaultName DisplayString, + sysAlarmCustomName DisplayString, + sysAlarmSeverity INTEGER , + sysAlarmToRelayMapping DisplayString , + sysAlarmOperStatus INTEGER + } + + sysAlarmIndex OBJECT-TYPE + SYNTAX INTEGER (0..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Index into system alarm table" + ::= { sysAlarmConfigEntry 1} + + sysAlarmDefaultName OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..8)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Default alarm name." + ::= { sysAlarmConfigEntry 2} + + sysAlarmCustomName OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..8)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A custom alarm name." + ::= { sysAlarmConfigEntry 3} + + sysAlarmSeverity OBJECT-TYPE + SYNTAX INTEGER { + none(0), + major(1), + minor(2), + majorAndMinor(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Alarm Severity as denoted by Major and Minor Alarm Mask" + ::= { sysAlarmConfigEntry 4} + + sysAlarmToRelayMapping OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..8)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "No additional mapping = 0 + Map to Relay A = 1 + Map to Relay B = 2 + Map to Relay C = 4 + Map to Relay D = 8 + Map to Relay E = 16 + Map to Relay F = 32 + Map to Relay A and B = (1 + 2) and so on + The major/minor classification of alarms automatically + associates it with Major/Minor relay. Assigning a null + mapping here does not override vpwrPMRelayAlarmSeverity for + the alarm. + It should be used to define mapping to additional relays. + " + ::= { sysAlarmConfigEntry 5} + + sysAlarmOperStatus OBJECT-TYPE + SYNTAX INTEGER { + inactive(0), + active(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates current alarm status" + ::= { sysAlarmConfigEntry 6} + + + + + sysAlarmComFailState OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1), + other(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable generation of comm fail alarm." + ::= { vpwrDcPowerAlarmGroup 4 } + + sysAlarmIShareState OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1), + other(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable generation of current share alarm." + ::= { vpwrDcPowerAlarmGroup 5} + + sysAlarmRedundancyState OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + nPlus1(1), + nPlus2(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable generation of redundancy alarm." + ::= { vpwrDcPowerAlarmGroup 6} + + sysAlarmComFailToACFailState OBJECT-TYPE + SYNTAX INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable generation of ACF upon Com Fail" + ::= { vpwrDcPowerAlarmGroup 7} + +------------------------------------------------------------------------------------------- + + vpwrDCPowerLampTest OBJECT-TYPE + SYNTAX INTEGER{ + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Lamp Test for modules" + ::= { eltek 5 } + + vpwrPMCnfgTable OBJECT-TYPE + SYNTAX SEQUENCE OF VpwrPMCnfgEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table shows the current configuration of the TRIO/PM86000/Controller inputs." + ::= { vpwrDcPowerPMModule 1 } + + vpwrPMCnfgEntry OBJECT-TYPE + SYNTAX VpwrPMCnfgEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing current configuration of the TRIO/PM86000/Controller inputs." + INDEX { vpwrPMIndex } + ::= { vpwrPMCnfgTable 1 } + + VpwrPMCnfgEntry ::= SEQUENCE { + vpwrPMIndex NonNegativeInteger, + vpwrPMDescription DisplayString, + vpwrPMCnfg1 VpwrPMCnfgValue, + vpwrPMCnfg2 VpwrPMCnfgValue, + vpwrPMCnfg3 VpwrPMCnfgValue, + vpwrPMCnfg4 VpwrPMCnfgValue, + vpwrPMCnfg5 VpwrPMCnfgValue, + vpwrPMCnfg6 VpwrPMCnfgValue, + vpwrPMCnfg7 VpwrPMCnfgValue, + vpwrPMCnfg8 VpwrPMCnfgValue + } + + vpwrPMIndex OBJECT-TYPE + SYNTAX NonNegativeInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " This parameter describes which TRIO/PM86000 device is being accessed." + ::= {vpwrPMCnfgEntry 1} + + vpwrPMDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " This parameter describes the configuration of the TRIO/PM86000 device." + ::= {vpwrPMCnfgEntry 2} + + vpwrPMCnfg1 OBJECT-TYPE + SYNTAX VpwrPMCnfgValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter gets the current configuration of the TRIO/PM86000, input 1" + ::= {vpwrPMCnfgEntry 3} + + vpwrPMCnfg2 OBJECT-TYPE + SYNTAX VpwrPMCnfgValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter gets the current configuration of the TRIO/PM86000, input 2" + ::= {vpwrPMCnfgEntry 4} + + vpwrPMCnfg3 OBJECT-TYPE + SYNTAX VpwrPMCnfgValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter gets the current configuration of the TRIO/PM86000, input 3" + ::= {vpwrPMCnfgEntry 5} + + vpwrPMCnfg4 OBJECT-TYPE + SYNTAX VpwrPMCnfgValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter gets the current configuration of the TRIO/PM86000, input 4" + ::= {vpwrPMCnfgEntry 6} + + vpwrPMCnfg5 OBJECT-TYPE + SYNTAX VpwrPMCnfgValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter gets the current configuration of the TRIO/PM86000, input 5" + ::= {vpwrPMCnfgEntry 7} + + vpwrPMCnfg6 OBJECT-TYPE + SYNTAX VpwrPMCnfgValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter gets the current configuration of the TRIO/PM86000, input 6" + ::= {vpwrPMCnfgEntry 8} + + vpwrPMCnfg7 OBJECT-TYPE + SYNTAX VpwrPMCnfgValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter gets the current configuration of the TRIO (PM86000), input 7" + ::= {vpwrPMCnfgEntry 9} + + vpwrPMCnfg8 OBJECT-TYPE + SYNTAX VpwrPMCnfgValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter gets the current configuration of the TRIO/PM86000, input 8" + ::= {vpwrPMCnfgEntry 10} + +------------------------------------------------------------------------------------------- + + vpwrPMInputStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF VpwrPMInputStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table shows the current values of the TRIO/PM86000/Controller inputs." + ::= { vpwrDcPowerPMModule 2 } + + vpwrPMInputStatusEntry OBJECT-TYPE + SYNTAX VpwrPMInputStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing current state of the TRIO/PM86000/Controller inputs." + INDEX { vpwrPMIndex1 } + ::= { vpwrPMInputStatusTable 1 } + + VpwrPMInputStatusEntry ::= SEQUENCE { + vpwrPMIndex1 NonNegativeInteger, + vpwrPMDescription1 DisplayString, + vpwrPMInput1State SysInputValue, + vpwrPMInput2State SysInputValue, + vpwrPMInput3State SysInputValue, + vpwrPMInput4State SysInputValue, + vpwrPMInput5State SysInputValue, + vpwrPMInput6State SysInputValue, + vpwrPMInput7State SysInputValue, + vpwrPMInput8State SysInputValue + } + + vpwrPMIndex1 OBJECT-TYPE + SYNTAX NonNegativeInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " This parameter describes which TRIO/PM86000 device is being accessed." + ::= {vpwrPMInputStatusEntry 1} + + vpwrPMDescription1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " This parameter describes the input values of the TRIO/PM86000 device." + ::= {vpwrPMInputStatusEntry 2} + + vpwrPMInput1State OBJECT-TYPE + SYNTAX SysInputValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " This parameter gets the current state of input 1" + ::= {vpwrPMInputStatusEntry 3} + + vpwrPMInput2State OBJECT-TYPE + SYNTAX SysInputValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " This parameter gets the current state of input 2" + ::= {vpwrPMInputStatusEntry 4} + + vpwrPMInput3State OBJECT-TYPE + SYNTAX SysInputValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " This parameter gets the current state of input 3" + ::= {vpwrPMInputStatusEntry 5} + + vpwrPMInput4State OBJECT-TYPE + SYNTAX SysInputValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " This parameter gets the current state of input 4" + ::= {vpwrPMInputStatusEntry 6} + + vpwrPMInput5State OBJECT-TYPE + SYNTAX SysInputValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " This parameter gets the current state of input 5" + ::= {vpwrPMInputStatusEntry 7} + + vpwrPMInput6State OBJECT-TYPE + SYNTAX SysInputValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " This parameter gets the current state of input 6" + ::= {vpwrPMInputStatusEntry 8} + + vpwrPMInput7State OBJECT-TYPE + SYNTAX SysInputValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " This parameter gets the current state of input 7" + ::= {vpwrPMInputStatusEntry 9} + + vpwrPMInput8State OBJECT-TYPE + SYNTAX SysInputValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " This parameter gets the current state of input 8" + ::= {vpwrPMInputStatusEntry 10} + +------------------------------------------------------------------------------------------- + vpwrPMRelayCtrlTable OBJECT-TYPE + SYNTAX SEQUENCE OF VpwrPMRelayCtrlEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table describes/controls system relays." + ::= { vpwrDcPowerPMModule 3 } + + vpwrPMRelayCtrlEntry OBJECT-TYPE + SYNTAX VpwrPMRelayCtrlEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing current state of the relays." + INDEX { vpwrPMIndex2 } + ::= { vpwrPMRelayCtrlTable 1 } + + VpwrPMRelayCtrlEntry ::= SEQUENCE { + vpwrPMIndex2 NonNegativeInteger, + vpwrPMDescription2 DisplayString, + vpwrPMRelay1State INTEGER, + vpwrPMRelay2State INTEGER, + vpwrPMRelay3State INTEGER, + vpwrPMRelay4State INTEGER, + vpwrPMRelay5State INTEGER, + vpwrPMRelay6State INTEGER + } + + vpwrPMIndex2 OBJECT-TYPE + SYNTAX NonNegativeInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " This parameter describes the TRIO/PM device" + ::= {vpwrPMRelayCtrlEntry 1} + + vpwrPMDescription2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " This parameter describes the TRIO/PM device" + ::= {vpwrPMRelayCtrlEntry 2} + + vpwrPMRelay1State OBJECT-TYPE + SYNTAX INTEGER { + vpwrPMRelayOff(0), + vpwrPMRelayOn(1), + undefined(255) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter sets the current state of relay 1" + ::= {vpwrPMRelayCtrlEntry 3} + + vpwrPMRelay2State OBJECT-TYPE + SYNTAX INTEGER { + vpwrPMRelayOff(0), + vpwrPMRelayOn(1), + undefined(255) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter sets the current state of relay 2" + ::= {vpwrPMRelayCtrlEntry 4} + + vpwrPMRelay3State OBJECT-TYPE + SYNTAX INTEGER { + vpwrPMRelayOff(0), + vpwrPMRelayOn(1), + undefined(255) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter sets the current state of relay 3" + ::= {vpwrPMRelayCtrlEntry 5} + + vpwrPMRelay4State OBJECT-TYPE + SYNTAX INTEGER { + vpwrPMRelayOff(0), + vpwrPMRelayOn(1), + undefined(255) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter sets the current state of relay 4" + ::= {vpwrPMRelayCtrlEntry 6} + + vpwrPMRelay5State OBJECT-TYPE + SYNTAX INTEGER { + vpwrPMRelayOff(0), + vpwrPMRelayOn(1), + undefined(255) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter sets the current state of relay 5" + ::= {vpwrPMRelayCtrlEntry 7} + + vpwrPMRelay6State OBJECT-TYPE + SYNTAX INTEGER { + vpwrPMRelayOff(0), + vpwrPMRelayOn(1), + undefined(255) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter sets the current state of relay 6" + ::= {vpwrPMRelayCtrlEntry 8} + + + + -- + -- The Ringer Configuration Parameters group. + -- + + + vpwrRingerIndex OBJECT-TYPE + SYNTAX INTEGER (0..2) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter allows selecting ringer A or Ringer B as the active ringer. + " + ::= {vpwrRingerConfigGroup 1} + + vpwrRingerParameterAdminState OBJECT-TYPE + SYNTAX INTEGER { + ringerDisabled(0), + ringerAOn(1) , + ringerBOn(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter allows selecting ringer A or Ringer B as the active ringer. + " + ::= {vpwrRingerConfigGroup 2} + + vpwrRingerParameterAcVoltage OBJECT-TYPE + SYNTAX INTEGER (7000..10000) + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter sets the output AC voltage of the ringer. + " + ::= {vpwrRingerConfigGroup 3} + + vpwrRingerParameterDcVoltage OBJECT-TYPE + SYNTAX INTEGER (0..5500 ) + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter sets the DC offset value of the ringer. + " + ::= {vpwrRingerConfigGroup 4} + + vpwrRingerParameterFrequency OBJECT-TYPE + SYNTAX INTEGER (17..50) + UNITS " Hz" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter sets the ringer AC frequency. + " + ::= {vpwrRingerConfigGroup 5} + + vpwrRingerNumberPresent OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The present number of ringer modules." + ::= { vpwrRingerConfigGroup 6 } + + +-- +-- ringer Alarm Group +-- + + vpwrRingerAlarmAFailed OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Ringer A Failed" + ::= {vpwrRingerAlarmGroup 1 } + + vpwrRingerAlarmAOverTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Ringer A Heatsink Over-Temperature" + ::= {vpwrRingerAlarmGroup 2 } + + vpwrRingerAlarmAOverCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Ringer A Over-Current protection" + ::= {vpwrRingerAlarmGroup 3 } + + vpwrRingerAlarmBFailed OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Ringer B Failed" + ::= {vpwrRingerAlarmGroup 4 } + + vpwrRingerAlarmBOverTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Ringer B Heatsink Over-Temperature" + ::= {vpwrRingerAlarmGroup 5 } + + vpwrRingerAlarmBOverCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Ringer B Over-Current protection" + ::= {vpwrRingerAlarmGroup 6 } + + + + vpwrBoostAdminState OBJECT-TYPE + SYNTAX INTEGER { + boostDisabled(0), + boostEnabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter allows enabling or disabling boost. + " + REFERENCE " " + + ::= {vpwrBatteryBoostGroup 1} + + vpwrBoostVoltage OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + " + REFERENCE " " + ::= {vpwrBatteryBoostGroup 2} + + vpwrBoostDuration OBJECT-TYPE + SYNTAX INTEGER (1..921599) + UNITS "Seconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " Number of seconds for boost. + " + REFERENCE " " + ::= {vpwrBatteryBoostGroup 3} + + vpwrBoostOperState OBJECT-TYPE + SYNTAX INTEGER { + boostInactive(0), + boostActive(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter allows starting or stopping boost if it is enabled. + " + REFERENCE " " + + ::= {vpwrBatteryBoostGroup 4} + + + vpwrBatteryCurrentLimitAdminState OBJECT-TYPE + SYNTAX INTEGER { + batteryCurrentLimitDisabled(0), + batteryCurrentLimitEnabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " This parameter allows enabling or disabling battery current limit. + " + REFERENCE " " + + ::= {vpwrBatteryCurrentGroup 1} + + vpwrBatteryCurrentLimit OBJECT-TYPE + SYNTAX INTEGER (5..600) + UNITS "Ampere" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " + " + REFERENCE " " + ::= {vpwrBatteryCurrentGroup 2} + + vpwrBatteryCurrent OBJECT-TYPE + SYNTAX INTEGER + UNITS "Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Battery current + " + REFERENCE " " + ::= {vpwrBatteryCurrentGroup 3} + + + + vpwrBDTAdminState OBJECT-TYPE + SYNTAX INTEGER { + bdtManualDisabled(0), + bdtManualEnabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " Enable / Disable Battery Discharge Test execution. + " + REFERENCE " " + + ::= {vpwrBatteryDischargeTestGroup 1} + + vpwrBDTDuration OBJECT-TYPE + SYNTAX INTEGER (0..64799) + UNITS "Seconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "BDT Duration Setpoint. + " + REFERENCE " " + ::= {vpwrBatteryDischargeTestGroup 2} + vpwrBDTAlarmVoltage OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "BDT Alarm Voltage Setpoint. + " + REFERENCE " " + ::= {vpwrBatteryDischargeTestGroup 3} + + vpwrBDTAbortVoltage OBJECT-TYPE + SYNTAX INTEGER + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "BDT Abort Voltage Setpoint. + " + REFERENCE " " + ::= {vpwrBatteryDischargeTestGroup 4} + + vpwrBDTAlarmCoefficient OBJECT-TYPE + SYNTAX INTEGER + UNITS "None" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Deprecated. Always returns 1 + " + REFERENCE " " + ::= {vpwrBatteryDischargeTestGroup 5} + + vpwrBDTOperState OBJECT-TYPE + SYNTAX INTEGER { + bdtInactive(0), + bdtManualStart(1), + bdtACFailStart(14) + + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " Start/Stop Battery Discharge Test execution. + " + REFERENCE " " + + ::= {vpwrBatteryDischargeTestGroup 6} + + vpwrBDTClearAlarm OBJECT-TYPE + SYNTAX INTEGER { + bdtNoAlarm(0), + bdtAlarmPresent(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " Clears any active BDT alarm. + " + REFERENCE " " + + ::= {vpwrBatteryDischargeTestGroup 7} + + vpwrBDTActualTime OBJECT-TYPE + SYNTAX INTEGER + UNITS "minutes" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " Actual BDT runtime in minutes. + " + REFERENCE " " + + ::= {vpwrBatteryDischargeTestGroup 8} + + vpwrBDTAlarmDelay OBJECT-TYPE + SYNTAX INTEGER + UNITS "minutes" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " Delay, in minutes, before checking and raising + BDT alarm. + Test: Plant Voltage <= BDTAlarmVoltage + " + REFERENCE " " + + ::= {vpwrBatteryDischargeTestGroup 9} + vpwrBDTResult OBJECT-TYPE + SYNTAX BDTResultTC + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " Results of BDT. + " + REFERENCE " " + + ::= {vpwrBatteryDischargeTestGroup 10} + + vpwrBDTAutoAdminState OBJECT-TYPE + SYNTAX INTEGER { + bdtAutoDisabled(0), + bdtAutoEnabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " Enable /Disable Battery Discharge Test data collection + upon detecting AC Fail condition. + " + REFERENCE " " + + ::= {vpwrBatteryDischargeTestGroup 11} + +-- +-- BDT History Start + -- + -- The System History group. + -- + vpwrBDTHistTable OBJECT-TYPE + SYNTAX SEQUENCE OF VpwrBDTHistEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " This table provides results of past BDT test. + " + ::= { vpwrBatteryDischargeTestGroup 12 } + + + vpwrBDTHistEntry OBJECT-TYPE + SYNTAX VpwrBDTHistEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing information applicable to a + particular BDT History." + + INDEX { vpwrBDTHistIndex } + + ::= { vpwrBDTHistTable 1 } + VpwrBDTHistEntry ::= SEQUENCE { + vpwrBDTHistIndex PositiveInteger, + vpwrBDTHistDateTime DisplayString, + vpwrBDTHistDuration PositiveInteger, + vpwrBDTHistAlarmVoltage PositiveInteger, + vpwrBDTHistAbortVoltage PositiveInteger, + vpwrBDTHistStartMethod BDTStartSourceTC, + vpwrBDTHistResult BDTResultTC, + vpwrBDTHistActualTime PositiveInteger, + vpwrBDTHistStartVoltage PositiveInteger, + vpwrBDTHistEndVoltage PositiveInteger + } + + vpwrBDTHistIndex OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "BDT History index." + ::= { vpwrBDTHistEntry 1 } + + vpwrBDTHistDateTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " BDT run date as + yr-mm-dd hh:mm + " + REFERENCE " " + ::= {vpwrBDTHistEntry 2} + vpwrBDTHistDuration OBJECT-TYPE + SYNTAX PositiveInteger + UNITS "Minutes" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "BDT duration at the time + this test was run. + " + REFERENCE " " + ::= {vpwrBDTHistEntry 3} + + vpwrBDTHistAlarmVoltage OBJECT-TYPE + SYNTAX PositiveInteger + UNITS " *.01 Volts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "BDT Alarm Voltage setpoint when + this test was run. + " + REFERENCE " " + ::= {vpwrBDTHistEntry 4} + + vpwrBDTHistAbortVoltage OBJECT-TYPE + SYNTAX PositiveInteger + UNITS " *.01 Volts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "BDT Abort Voltage setpoint when + this test was run. + " + REFERENCE " " + ::= {vpwrBDTHistEntry 5} + + + vpwrBDTHistStartMethod OBJECT-TYPE + SYNTAX BDTStartSourceTC + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "How Battery Discharge Test + was started. + " + REFERENCE " " + + ::= {vpwrBDTHistEntry 6} + + vpwrBDTHistResult OBJECT-TYPE + SYNTAX BDTResultTC + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " Results of BDT. + " + REFERENCE " " + + ::= {vpwrBDTHistEntry 7} + + vpwrBDTHistActualTime OBJECT-TYPE + SYNTAX PositiveInteger + UNITS "minutes" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " Actual BDT runtime in minutes. + " + REFERENCE " " + + ::= {vpwrBDTHistEntry 8} + + vpwrBDTHistStartVoltage OBJECT-TYPE + SYNTAX PositiveInteger + UNITS " *.01 Volts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Plant Voltage at the time + the BDT was started. + " + REFERENCE " " + + ::= {vpwrBDTHistEntry 9} + vpwrBDTHistEndVoltage OBJECT-TYPE + SYNTAX PositiveInteger + UNITS " *.01 Volts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Plant Voltage at the time + the BDT was completed. + " + REFERENCE " " + + ::= {vpwrBDTHistEntry 10} + +-- BDT History End + +-- BDT scheduled Start + -- + -- The System History group. + -- + vpwrBDTSchedTable OBJECT-TYPE + SYNTAX SEQUENCE OF VpwrBDTSchedEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " This table provides the list of the 12 BDTs that can be + scheduled. Need to set date(month and day) and + time (hh and minutes) when the test should be + started. + " + ::= { vpwrBatteryDischargeTestGroup 13 } + + + vpwrBDTSchedEntry OBJECT-TYPE + SYNTAX VpwrBDTSchedEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry describing an alarm." + INDEX { vpwrBDTSchedIndex} + ::= { vpwrBDTSchedTable 1 } + + VpwrBDTSchedEntry ::= SEQUENCE { + vpwrBDTSchedIndex PositiveInteger, + vpwrBDTSchedMonth PositiveInteger, + vpwrBDTSchedDay PositiveInteger, + vpwrBDTSchedHour PositiveInteger, + vpwrBDTSchedMinute PositiveInteger + } + + vpwrBDTSchedIndex OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "BDT Sched index." + ::= { vpwrBDTSchedEntry 1 } + + vpwrBDTSchedDay OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " 1 to 28,29,30 or 31 depending upon the month + " + REFERENCE " " + ::= {vpwrBDTSchedEntry 2} + + vpwrBDTSchedMonth OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " range 1 to 12 + " + REFERENCE " " + ::= {vpwrBDTSchedEntry 3} + + vpwrBDTSchedHour OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " range 0 to 23 + " + REFERENCE " " + ::= {vpwrBDTSchedEntry 4} + + vpwrBDTSchedMinute OBJECT-TYPE + SYNTAX PositiveInteger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + " range 0 to 59 + " + REFERENCE " " + ::= {vpwrBDTSchedEntry 5} + + +-- BDT Scheduled End + +-- +-- traps +-- +-- New Rules for trap numbering +-- Rules are even number = trap set +-- odd number = trap clear + +vpwrTrapPowerMajorAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "Major Alarm" + ::= {vpwrDcPowerTraps 1} + + vpwrTrapPowerMinorAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "Minor Alarm" + ::= {vpwrDcPowerTraps 2} + + vpwrTrapACFAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "AC Fail Alarm" + ::= {vpwrDcPowerTraps 3} + + vpwrTrapHVAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "High Voltage Warning Alarm" + ::= {vpwrDcPowerTraps 4} + + vpwrTrapHVSDAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "High Voltage Shutdown Alarm" + ::= {vpwrDcPowerTraps 5} + + vpwrTrapBDAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "Battery on Discharge Alarm" + ::= {vpwrDcPowerTraps 6} + + vpwrTrapLVDWarningAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "LVD Warning Alarm" + ::= {vpwrDcPowerTraps 7} + + vpwrTrapLVDOpenAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "LVD Open Alarm" + ::= {vpwrDcPowerTraps 8} + + vpwrTrapDistAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "Distribution Open Alarm" + ::= {vpwrDcPowerTraps 9} + + vpwrTrapAuxAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "Auxiliary System Alarm" + ::= {vpwrDcPowerTraps 10} + + vpwrTrapSystemRedundancyAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "System Redundant Capacity Alarm" + ::= {vpwrDcPowerTraps 11} + + vpwrTrapIShareAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "Rectifier Current Share Alarm" + ::= {vpwrDcPowerTraps 12} + + vpwrTrapModuleFailAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "Single Rectifier Fail Alarm" + ::= {vpwrDcPowerTraps 13} + + vpwrTrapMultipleModuleFailAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "Multiple Rectifier Fail Alarm" + ::= {vpwrDcPowerTraps 14} + + vpwrTrapModuleCommAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "Power Module Communication Alarm" + ::= {vpwrDcPowerTraps 15} + + vpwrTrapSystemOverTemperatureAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "System Over Temperature Alarm" + ::= {vpwrDcPowerTraps 16} + + vpwrTrapSystemOK NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "SYSTEM OK - No Active Alarms" + ::= {vpwrDcPowerTraps 17} + + vpwrTrapModuleInserted NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString, vpwrBayIndex, vpwrModuleIndex } + STATUS current + DESCRIPTION "A new module has been inserted into the system" + ::= {vpwrDcPowerTraps 18} + + vpwrTrapModuleRemoved NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString,vpwrBayIndex, vpwrModuleIndex } + STATUS current + DESCRIPTION "A module has been removed from the system" + ::= {vpwrDcPowerTraps 19} + + vpwrTrapThermalCompActive NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "Thermal compensation has become active" + ::= {vpwrDcPowerTraps 20} + + vpwrTrapThermalCompInactive NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "Thermal compensation has been de-activated" + ::= {vpwrDcPowerTraps 21} + + vpwrTrapInternalTempAlarmSet NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Internal Temperature upper threshold exceeded" + ::= {vpwrDcPowerTraps 22} + + vpwrTrapInternalTempAlarmCleared NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Internal Temperature within limits" + ::= {vpwrDcPowerTraps 23} + + vpwrTrapBatteryTempAlarmSet NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + At least one Battery Temperature exceeded upper threshold" + ::= {vpwrDcPowerTraps 24} + + vpwrTrapBatteryTempAlarmCleared NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + All Battery Temperatures within limits" + ::= {vpwrDcPowerTraps 25} + + vpwrTrapLoginFail NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Admin login failed due to wrong username/password" + ::= {vpwrDcPowerTraps 26} + + vpwrTrapLoginSuccess NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Admin login successful" + ::= {vpwrDcPowerTraps 27} + + vpwrTrapLogout NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Admin logout" + ::= {vpwrDcPowerTraps 28} + + vpwrTrapAdminPwdChange NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Config change submitted with invalid access" + ::= {vpwrDcPowerTraps 29} + + vpwrTrapIllegalConfigSubmit NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Config change submitted with invalid access" + ::= {vpwrDcPowerTraps 30} + + vpwrTrapCfgChange NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Config change submitted" + ::= {vpwrDcPowerTraps 31} + + vpwrTrapClearEventHistory NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Clear Event history buffer clear request" + ::= {vpwrDcPowerTraps 32} + + vpwrTrapSwDownloadNoReboot NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + System software upgrade without reboot" + ::= {vpwrDcPowerTraps 33} + + vpwrTrapSwDownloadAndReboot NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + System reboot due to software upgrade" + ::= {vpwrDcPowerTraps 34} + + vpwrTrapSystemClockChange NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + System clock updated" + ::= {vpwrDcPowerTraps 35} + + vpwrTrapModuleAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Module Alarm" + ::= {vpwrDcPowerTraps 36} + + vpwrTrapOIDChange NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Change in OID" + ::= {vpwrDcPowerTraps 37} + + vpwrTrapThermalRunaway NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "Thermal Runaway Alarm" + ::= {vpwrDcPowerTraps 38} + + vpwrTrapBatteryDischargeTestAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "System Voltage dropped to BDT Alarm Setpoint" + ::= {vpwrDcPowerTraps 39} + + vpwrTrapBayUnnameAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Unassigned Bay Fail Alarm" + ::= {vpwrDcPowerTraps 40} + + vpwrTrapPMComFailAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + PM Communication Fail Alarm" + ::= {vpwrDcPowerTraps 41} + + vpwrTrapFuseOverloadAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Fuse Overload Alarm" + ::= {vpwrDcPowerTraps 42} + + vpwrTrapPeripheralAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Peripheral Alarm." + ::= {vpwrDcPowerTraps 43} + + vpwrTrapThermalProbeAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "Thermal Probe Missing Alarm" + ::= {vpwrDcPowerTraps 44} + + vpwrTrapBayCommAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Bay Communication Alarm" + ::= {vpwrDcPowerTraps 45} + + vpwrTrapDistributionCommAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "Distribution Communication Alarm" + ::= {vpwrDcPowerTraps 46} + + vpwrTrapConverterAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Single Converter Fail Alarm" + ::= {vpwrDcPowerTraps 47} + + vpwrTrapMultipleConvFailAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Multiple Converter Fail Alarm" + ::= {vpwrDcPowerTraps 48} + + vpwrTrapDGUAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! For Future Use. !!! + DGU Alarm" + ::= {vpwrDcPowerTraps 49} + + vpwrTrapConfigErrorAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "Configuration Error" + ::= {vpwrDcPowerTraps 50} + + vpwrTrapDisplayFirmwareMismatchAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Display Firmware Mismatch" + ::= {vpwrDcPowerTraps 51} + + vpwrTrapConverterInputFailAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Converter Input Fail Alarm" + ::= {vpwrDcPowerTraps 52} + + vpwrTrapBatteryRechgIlimitFailAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Battery Recharge Current Limit Fail" + ::= {vpwrDcPowerTraps 53} + + vpwrTrapSystemAlive NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "Periodic Keepalive trap" + ::= {vpwrDcPowerTraps 54} + + vpwrTrapSystemAuxAlmSource NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString, + vpwrAlarmingModuleOID, + vpwrAlarmingModuleIndex, + vpwrAlarmingSubModuleBitMap } + STATUS current + DESCRIPTION + "Source of Auxilary Alarms. + Indicates the module and the aux within + the module causing alarms" + ::= {vpwrDcPowerTraps 55} + + vpwrTrapSystemDistAlmSource NOTIFICATION-TYPE + OBJECTS{ vpwrTrapsMsgString, + vpwrAlarmingModuleOID, + vpwrAlarmingModuleIndex, + vpwrAlarmingSubModuleBitMap } + STATUS current + DESCRIPTION + "Source of Distribution Alarms. + Indicates the module and the dist within + the module causing alarms" + ::= {vpwrDcPowerTraps 56} + + vpwrTrapSystemBatCapacityAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString, + vpwrSystemCurrent, + vpwrBatteryCurrentCapacity } + STATUS current + DESCRIPTION + "Plant Load exceeds Plant Battery Current Capacity. + Useful for batteries that limit maximum discharge current + It will not be sent out for VRLA batteries, eg" + + ::= {vpwrDcPowerTraps 58} + + vpwrTrapSystemACFClearAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString, + vpwrTrapAcfDuration} + STATUS current + DESCRIPTION + "AC Fail (ACF) Conditioned Cleared Alarm. + Duration is in minutes. + " + ::= {vpwrDcPowerTraps 61} + + vpwrTrapSystemACFSetAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString, + vpwrTrapAcfDuration} + STATUS current + DESCRIPTION + "ACF Conditioned detected Alarm. + The duration would always be zero. + Msg String: ACF Alarm Set + " + ::= {vpwrDcPowerTraps 62} + + vpwrTrapSystemBatCapacityLeft NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString, + vpwrBatteryRemainingTime } + STATUS current + DESCRIPTION + "!!! For Future Use. !!! + Battery Useful Capacity Remaining" + ::= {vpwrDcPowerTraps 64} + + vpwrTrapRectifierUVAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString, vpwrBayIndex, vpwrModuleIndex } + STATUS current + DESCRIPTION "Rectifier Under Voltage Alarm" + ::= {vpwrDcPowerTraps 65} + + vpwrTrapMultRectifierUVAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! For Future Use. !!! + Multiple Rectifier Under Voltage Alarm" + ::= {vpwrDcPowerTraps 66} + + vpwrTrapRingerAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "Ringer Alarm" + ::= {vpwrDcPowerTraps 67} + + vpwrTrapMultRingerAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString} + STATUS current + DESCRIPTION "!!! For Future Use. !!! + Multiple Ringer Alarm" + ::= {vpwrDcPowerTraps 68} + + vpwrTrapI2CCANAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString} + STATUS current + DESCRIPTION "!!! For Future Use. !!! + Unmapped I2C/CAN Address Alarm + One of your I2C or CAN devices + has a duplicate or invalid address + and can not be mapped. Please + recheck all device addresses." + ::= {vpwrDcPowerTraps 69} + +vpwrTrapRectifierIlimitAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString, vpwrBayIndex, vpwrModuleIndex } + STATUS current + DESCRIPTION "Rectifier Current Limit Alarm" + ::= {vpwrDcPowerTraps 70} + + vpwrTrapMultRectifierIlimitAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "!!! For Future Use. !!! + Multiple Rectifier Current Limit Alarm" + ::= {vpwrDcPowerTraps 71} + + vpwrTrapRingerCommAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString } + STATUS current + DESCRIPTION "Ringer Communication Alarm" + ::= {vpwrDcPowerTraps 72} + + vpwrTrapUnassignedAlarm NOTIFICATION-TYPE + OBJECTS { vpwrTrapsMsgString} + STATUS current + DESCRIPTION "!!! NOT VALID FOR BC2000 CONTROLLER !!! + Unassigned Alarm(Trap) - Check Web Page" + ::= {vpwrDcPowerTraps 99} + +END -- cgit v1.2.3