From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/gigamon/GIGAMON-SNMP-MIB | 813 ++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 813 insertions(+) create mode 100644 MIBS/gigamon/GIGAMON-SNMP-MIB (limited to 'MIBS/gigamon/GIGAMON-SNMP-MIB') diff --git a/MIBS/gigamon/GIGAMON-SNMP-MIB b/MIBS/gigamon/GIGAMON-SNMP-MIB new file mode 100644 index 0000000..7ebfc12 --- /dev/null +++ b/MIBS/gigamon/GIGAMON-SNMP-MIB @@ -0,0 +1,813 @@ +GIGAMON-SNMP-MIB DEFINITIONS ::= BEGIN + +-- +-- Gigamon MIB objects for agent module +-- + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, enterprises, Integer32, Unsigned32, + NOTIFICATION-TYPE FROM SNMPv2-SMI + sysLocation FROM RFC1213-MIB + TEXTUAL-CONVENTION, DisplayString, + PhysAddress, TimeStamp FROM SNMPv2-TC; + +gigamonSnmp MODULE-IDENTITY + LAST-UPDATED "201805150000Z" + ORGANIZATION "www.gigamon.com" + CONTACT-INFO + "postal: Gigamon LLC + 598 Gibraltar Drive + Milpitas, CA 95035 + + email: support@gigamon.com" + DESCRIPTION + "Top-level infrastructure of Gigamon's MIB objects for + GigaVUE-212, GigaVUE-420, GigaVUE-2404, + GigaVUE-HD and GigaVUE-TA1" + + -- HISTORY + REVISION "201805150000Z" + DESCRIPTION + " Fixed smilint errors" + + REVISION "201309250000Z" + DESCRIPTION + "Added powerSupply OID to gigamonSystem MIB group" + + REVISION "201304150000Z" + DESCRIPTION + "Added 'license-mismatch' to gigamonSnmpNotifModuleOperationType" + + REVISION "201212040000Z" + DESCRIPTION + "Added 'up' to gigamonSnmpNotifModuleOperationType" + + REVISION "201205090000Z" + DESCRIPTION + "Added new information found under gigamonSystem MIB group + 1) Updated GigaVUE product line support: + (a) Added GigaVUE-TA1 + (b) Removed G-TAP and GigaVUE-MP + 2) Added speed40000 and speed100000 in gigamonSnmpPortLinkSpeed + for representing 40G and 100G port speed" + + REVISION "201203270000Z" + DESCRIPTION + "Added 'shutdown' to gigamonSnmpNotifModuleOperationType" + + REVISION "201103250000Z" + DESCRIPTION + "Added the following notifications: + - gigamonSnmpCpuUtilHighNotification + - gigamonSnmpUnexpectedShutdownNotification + - gigamonSnmpDiskSpaceLowNotification" + + REVISION "201103240000Z" + DESCRIPTION + "Added G-TAP support" + + REVISION "201103030000Z" + DESCRIPTION + "Added GigaVUE-HD support" + + REVISION "201007101000Z" + DESCRIPTION + "Created notification definitions. First draft" + + ::= { enterprises 26866 } + +-- +-- Gigamon's enterprise-specific management objects +-- +-- top level structure +-- +-- GigaVUE product line - GigaVUE-212, GigaVUE-420, GigaVUE-2404, +-- GigaVUE-HD, GigaVUE-TA1 +gigamonSnmpNotifications OBJECT IDENTIFIER ::= { gigamonSnmp 1 } +gigamonGigaVUE OBJECT IDENTIFIER ::= { gigamonSnmpNotifications 1 } +gigamonSnmpNotificationObjects OBJECT IDENTIFIER + ::= { gigamonSnmpNotifications 2 } + +gigamonSystem OBJECT IDENTIFIER ::= { gigamonSnmp 2 } + +------------------------------------------ +-- System Information +------------------------------------------ +manufacturer OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the manufacturer name of the system." +::= { gigamonSystem 1 } + +model OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the model name of the system." +::= { gigamonSystem 2 } + +name OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the name of the system." +::= { gigamonSystem 3 } + +serialNumber OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the serial number of the system." +::= { gigamonSystem 4 } + +systemDescription OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the description of the system." +::= { gigamonSystem 5 } + +version OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the software version of the system." +::= { gigamonSystem 6 } + +chassisModelNumber OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the chassis model number of the system." +::= { gigamonSystem 7 } + +chassisSerialNumber OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the chassis serial number of the system." +::= { gigamonSystem 8 } + +bladeSerialNumbers OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the blade serial numbers in the system." +::= { gigamonSystem 9 } + +firmwareVersion OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the firmware version of the system." +::= { gigamonSystem 10 } + +hardwareVersion OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the hardware version of the system." +::= { gigamonSystem 11 } + +cpuRAMSize OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the CPU RAM size of the system." +::= { gigamonSystem 12 } + +cpuUtilization OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the CPU utilization of the system." +::= { gigamonSystem 13 } + +fans OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the fans in the system." +::= { gigamonSystem 14 } + +temperatureSensors OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the temperature sensors in the system." +::= { gigamonSystem 15 } + +powerSupply OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the power supplies in the system." +::= { gigamonSystem 16 } + +---- + +-- Product Type Information +gigamonProducts OBJECT IDENTIFIER ::= { gigamonSnmp 3 } +gigamonGV2404 OBJECT IDENTIFIER ::= { gigamonProducts 1 } +gigamonGV420 OBJECT IDENTIFIER ::= { gigamonProducts 2 } +gigamonGV212 OBJECT IDENTIFIER ::= { gigamonProducts 3 } +gigamonGV216 OBJECT IDENTIFIER ::= { gigamonProducts 4 } + +---- + +------------------------------------------ +-- Objects used in Gigamon Notifications +------------------------------------------ +gigamonSnmpNotifLevel OBJECT-TYPE + SYNTAX INTEGER { + information(1), + minor(2), + major(3), + critical(4) + } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "It acts as a payload for the level of Gigamon's Notifications." +::= { gigamonSnmpNotificationObjects 1 } + +gigamonSnmpNotifDescription OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "It acts as a payload for the description of Gigamon's Notifications. + The value is to describe the reason for the notification." +::= { gigamonSnmpNotificationObjects 2 } + +gigamonSnmpNotifOpType OBJECT-TYPE + SYNTAX INTEGER { + read(1), + write(2), + delete(3), + validate(4), + change(5) + } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "It specifies the type of operation of Gigamon's Notifications." +::= { gigamonSnmpNotificationObjects 3 } + +gigamonSnmpNotifPortName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The alpha-numerical name of a port shown in Gigamon's Notifications." +::= { gigamonSnmpNotificationObjects 4 } + +gigamonSnmpNotifPortLinkStatus OBJECT-TYPE + SYNTAX INTEGER { + down(0), + up(1) + } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "It indicates port link status of Gigamon's Notifications." +::= { gigamonSnmpNotificationObjects 5 } + +gigamonSnmpNotifTAPRelayStatus OBJECT-TYPE + SYNTAX INTEGER { + none(0), + passive(1), + active(2) + } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "It indicates TAP relay status of Gigamon's Notifications." +::= { gigamonSnmpNotificationObjects 6 } + +gigamonSnmpNotifRxTxType OBJECT-TYPE + SYNTAX INTEGER { + rx(0), + tx(1) + } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "It indicates Incoming/RX or outgoing/TX packets" +::= { gigamonSnmpNotificationObjects 7 } + +gigamonSnmpNotifRxTxErrorType OBJECT-TYPE + SYNTAX INTEGER { + under-size(0), + fragments(1), + obsolete(2), + jabbers(3), + crc-align(4), + unknown(5) + } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "It indicates RX/TX error type of Gigamon's Notifications." +::= { gigamonSnmpNotificationObjects 8 } + +gigamonSnmpNotifCounter OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "32-bit Counter." +::= { gigamonSnmpNotificationObjects 9 } + +gigamonSnmpNotifFirmwareName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Name of GigaVUE firmware." +::= { gigamonSnmpNotificationObjects 10 } + +gigamonSnmpNotifModuleOperationType OBJECT-TYPE + SYNTAX INTEGER { + removed(0), + inserted(1), + changed(2), + mismatch(3), + shutdown(4), + up(5), + license-mismatch(6) + } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "It indicates the operation performed on module" +::= { gigamonSnmpNotificationObjects 11 } + +gigamonSnmpNotifModuleName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Module name of GigaVUE module" +::= { gigamonSnmpNotificationObjects 12 } + +gigamonNotifSlotNumber OBJECT-TYPE + SYNTAX INTEGER { + mid-plane(0), + slot-1(1), + slot-2(2), + slot-3(3), + gigaLink-Back(4), + daughter-Card(5), + slot-4(10), + slot-5(11), + slot-6(12), + slot-7(13), + slot-8(14), + slot-CC1(15), + slot-CC2(16) + } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Slot number" +::= { gigamonSnmpNotificationObjects 13 } + +gigamonSnmpNotifUserName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "User login name typed in" +::= { gigamonSnmpNotificationObjects 14 } + +gigamonSnmpNotifFileName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Saved configuration file name" +::= { gigamonSnmpNotificationObjects 15 } + +gigamonNotifPowerStatus OBJECT-TYPE + SYNTAX INTEGER { + failure(-1), + abnormal(0), + normal(1) + } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Power Status" +::= { gigamonSnmpNotificationObjects 16 } + +gigamonSnmpNotifHardWareName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Description of Hardware" +::= { gigamonSnmpNotificationObjects 17 } + +gigamonSnmpNotifGigaVUE420SlotNumber OBJECT-TYPE + SYNTAX INTEGER { + mid-plane(0), + expansion-slot-1(1), + expansion-slot-2(2), + expansion-slot-3(3), + expansion-slot-4(4), + expansion-slot-5(5), + x1-slot(6), + x2-slot(7), + x3-slot(8), + x4-slot(9) + } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Slot number" +::= { gigamonSnmpNotificationObjects 18 } + +gigamonSnmpNotifFanName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Name of fan" +::= { gigamonSnmpNotificationObjects 19 } + +gigamonNotifFanStatus OBJECT-TYPE + SYNTAX INTEGER { + failure(-1), + abnormal(0), + normal(1) + } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Fan Status" +::= { gigamonSnmpNotificationObjects 20 } + +gigamonSnmpNotifUtilizationAlarm OBJECT-TYPE + SYNTAX INTEGER { + below(0), + exceed(1) + } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "It indicates over-threshold port utilization alarm of Gigamon's Notifications." +::= { gigamonSnmpNotificationObjects 21 } + +gigamonSnmpNotifUtilizationThreshold OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Utilization threshold percentage" +::= { gigamonSnmpNotificationObjects 22 } + +gigamonSnmpBatteryLevel OBJECT-TYPE + SYNTAX INTEGER { + batteryChargeComplete(0), + downBelow75(1), + downBelow50(2), + downBelow25(3), + shutDownSystem(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " battery level: + 0 - battery charge complete + 1 - battery level has been down below 75% + 2 - battery level has been down below 50% + 3 - battery level has been down below 25% + 4 - battery level has down to 15% or below and shutting down the system " + ::= { gigamonSnmpNotificationObjects 23 } + +gigamonSnmpPortLinkSpeed OBJECT-TYPE + SYNTAX INTEGER { + notApply(0), + speed10(1), + speed100(2), + speed1000(3), + speed10000(4), + speed40000(5), + speed100000(6) + } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + " port link speed: + 0 - Not Apply if link is down + 1 - 10 Mbps + 2 - 100 Mbps + 3 - 1000 Mbps + 4 - 10000 Mbps + 5 - 40000 Mbps + 6 - 100000 Mbps " + ::= { gigamonSnmpNotificationObjects 24 } + +gigamonSnmpPortLinkDuplex OBJECT-TYPE + SYNTAX INTEGER { + notApply(0), + full(1), + half(2) + } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + " port link duplex: + 0 - Not Apply if link is down + 1 - full duplex + 2 - half duplex " + ::= { gigamonSnmpNotificationObjects 25 } + +gigamonSnmpNotifCpuIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Index of CPU, starting from 0" + ::= { gigamonSnmpNotificationObjects 26 } + +gigamonSnmpNotifFsMountPoint OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Mount point for this filesystem" + ::= { gigamonSnmpNotificationObjects 27 } + +gigamonSnmpPowerSource OBJECT-TYPE + SYNTAX INTEGER { + mainPower(0), + poe(1), + power48V(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " power source: + 0 - main power + 1 - poe(Power over Ethernet) + 2 - -48V Power " + ::= { gigamonSnmpNotificationObjects 28 } + +gigamonSnmpNotifBpsUnitName OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Name of BPS unit" + ::= { gigamonSnmpNotificationObjects 29 } + +gigamonSnmpNotifBpsFailoverStatus OBJECT-TYPE + SYNTAX INTEGER { + primary(0), + secondary(1) + } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Inline-bypass active unit change" + ::= { gigamonSnmpNotificationObjects 30 } + +--------------------------- +-- Gigamon Notifications +--------------------------- +gigamonSnmpResetSystemNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription} + STATUS current + DESCRIPTION + "System reset notification triggered by cold or warm start." + ::= { gigamonGigaVUE 1 } + +gigamonSnmpUserAuthFailNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription, + gigamonSnmpNotifUserName} + STATUS current + DESCRIPTION + "Failure in user login operation is the triggered Event." + ::= { gigamonGigaVUE 2 } + +gigamonSnmpFirmwareChangeNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription, + gigamonSnmpNotifFirmwareName } + STATUS current + DESCRIPTION + "Firmware Change notification is the Edge/Level Triggered Event." + ::= { gigamonGigaVUE 3 } + +gigamonSnmpConfigSaveNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription, + gigamonSnmpNotifFileName } + STATUS current + DESCRIPTION + "Config save notification is the Edge/Level Triggered Event." + ::= { gigamonGigaVUE 4 } + +gigamonSnmpModuleChangeNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription, + gigamonSnmpNotifModuleOperationType, + gigamonSnmpNotifModuleName, + gigamonNotifSlotNumber } + STATUS current + DESCRIPTION + "GigaVUE HW module swapping is the triggered Event." + ::= { gigamonGigaVUE 5 } + +gigamonSnmpPacketDropNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription, + gigamonSnmpNotifPortName, + gigamonSnmpNotifCounter } + STATUS current + DESCRIPTION + "Packet Drop notification is the Edge/Level Triggered Event." + ::= { gigamonGigaVUE 6 } + + +gigamonSnmpTapRelayChangeNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription, + gigamonSnmpNotifPortName, + gigamonSnmpNotifTAPRelayStatus } + STATUS current + DESCRIPTION + "TAP relay change notification is the Edge/Level Triggered Event." + ::= { gigamonGigaVUE 7 } + +gigamonSnmpPortLinkChangeNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription, + gigamonSnmpNotifPortName, + gigamonSnmpNotifPortLinkStatus } + STATUS current + DESCRIPTION + "Port link status change notification is the Edge/Level Triggered Event." + ::= { gigamonGigaVUE 8 } + +gigamonSnmpRxTxErrorNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription, + gigamonSnmpNotifPortName, + gigamonSnmpNotifRxTxType, + gigamonSnmpNotifRxTxErrorType, + gigamonSnmpNotifCounter } + STATUS current + DESCRIPTION + "Packet receive/transmit error notification is the Edge/Level Triggered Event." + ::= { gigamonGigaVUE 9 } + +gigamonPowerChangeNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription, + gigamonNotifPowerStatus } + STATUS current + DESCRIPTION + "Power supply status change notification is the Edge/Level Triggered Event." + ::= { gigamonGigaVUE 10 } + +gigamonFanChangeNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription, + gigamonSnmpNotifFanName, + gigamonNotifFanStatus } + STATUS current + DESCRIPTION + "Fan status change notification is the Edge/Level Triggered Event." + ::= { gigamonGigaVUE 11 } + +gigamonSnmpOverThresholdChangeNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription, + gigamonSnmpNotifPortName, + gigamonSnmpNotifUtilizationAlarm, + gigamonSnmpNotifUtilizationThreshold } + STATUS current + DESCRIPTION + "Utilization alarm notification is the Edge/Level Triggered Event." + ::= { gigamonGigaVUE 12 } + +gigamonSnmpBatteryLevelChangeNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription, + gigamonSnmpBatteryLevel } + STATUS current + DESCRIPTION + "Battery level down notification." + ::= { gigamonGigaVUE 13 } + +gigamonLinkSpeedStatusChangeNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription, + gigamonSnmpNotifPortName, + gigamonSnmpPortLinkSpeed, + gigamonSnmpPortLinkDuplex, + gigamonSnmpNotifPortLinkStatus } + STATUS current + DESCRIPTION + "Link status or speed change notification. " + ::= { gigamonGigaVUE 14 } + +gigamonPowerSourceChangeNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription, + gigamonSnmpPowerSource, + gigamonNotifPowerStatus } + STATUS current + DESCRIPTION + "Power source or status change notification." + ::= { gigamonGigaVUE 15 } + +gigamonSnmpCpuUtilHighNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription, + gigamonSnmpNotifCpuIndex, + gigamonSnmpNotifUtilizationThreshold } + STATUS current + DESCRIPTION + "The average CPU utilization in the past minute has gone + above the acceptable threshold" + ::= { gigamonGigaVUE 16 } + +gigamonSnmpUnexpectedShutdownNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription } + STATUS current + DESCRIPTION + "The system has shut down unexpectedly" + ::= { gigamonGigaVUE 17 } + +gigamonSnmpDiskSpaceLowNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription, + gigamonSnmpNotifFsMountPoint } + STATUS current + DESCRIPTION + "Free space in one of the filesystems is low" + ::= { gigamonGigaVUE 18 } + +gigamonSnmpWatchdogResetNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription} + STATUS current + DESCRIPTION + "System reset notification triggered by watchdog timer." + ::= { gigamonGigaVUE 19 } + +gigamonSnmpBpsFailoverNotification NOTIFICATION-TYPE + OBJECTS { gigamonSnmpNotifHardWareName, + gigamonSnmpNotifLevel, + gigamonSnmpNotifDescription, + gigamonSnmpNotifBpsUnitName, + gigamonSnmpNotifBpsFailoverStatus } + STATUS current + DESCRIPTION + "Inline-bypass active unit change notification is the Edge/Level Triggered Event." + ::= { gigamonGigaVUE 20 } + +END -- cgit v1.2.3