From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/liebert/LIEBERT-GP-FLEXIBLE-COND-MIB | 5534 +++++++++++++++++++++++++++++ 1 file changed, 5534 insertions(+) create mode 100644 MIBS/liebert/LIEBERT-GP-FLEXIBLE-COND-MIB (limited to 'MIBS/liebert/LIEBERT-GP-FLEXIBLE-COND-MIB') diff --git a/MIBS/liebert/LIEBERT-GP-FLEXIBLE-COND-MIB b/MIBS/liebert/LIEBERT-GP-FLEXIBLE-COND-MIB new file mode 100644 index 0000000..43b1dbb --- /dev/null +++ b/MIBS/liebert/LIEBERT-GP-FLEXIBLE-COND-MIB @@ -0,0 +1,5534 @@ +LIEBERT-GP-FLEXIBLE-CONDITIONS-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, + OBJECT-IDENTITY + FROM SNMPv2-SMI + liebertFlexibleConditionsModuleReg + FROM LIEBERT-GP-REGISTRATION-MIB + lgpFlexConditions + FROM LIEBERT-GP-CONDITIONS-MIB + ; + +-- ============================================================================= +-- Module Identification and Registration +-- ============================================================================= + +liebertGlobalProductsFlexibleConditionsModule MODULE-IDENTITY + LAST-UPDATED "201810020000Z" + ORGANIZATION "Liebert Corporation" + CONTACT-INFO + "Contact: Technical Support + + Postal: + Liebert Corporation + 1050 Dearborn Drive + P.O. Box 29186 + Columbus OH, 43229 + US + + Tel: +1 (800) 222-5877 + + E-mail: liebert.monitoring@vertivco.com + Web: www.vertivco.com" + + DESCRIPTION + "The MIB module used to register Liebert SNMP OIDs. + + Copyright 2000-2018 Liebert Corporation. All rights reserved. + Reproduction of this document is authorized on the condition + that the forgoing copyright notice is included. + + This Specification is supplied 'AS IS' and Liebert Corporation + makes no warranty, either express or implied, as to the use, + operation, condition, or performance of the Specification." + + REVISION "201810020000Z" + DESCRIPTION + "Compiled From GDD Version: 6825.1" + + + ::= { liebertFlexibleConditionsModuleReg 1 } + +-- ============================================================================= +-- lgpFlexConditions - Liebert Conditions Registrations +-- ============================================================================= + +lgpFlexConditionsWellKnown OBJECT IDENTIFIER + -- STATUS current + -- DESCRIPTION + -- "Liebert well known conditions are defined by OIDs that + -- reside in this sub-tree." + ::= { lgpFlexConditions 1 } + +-- ============================================================================= +-- lgpFlexConditionsWellKnown - Liebert "well-known" Conditions +-- ============================================================================= + +lgpCondId4122SystemInputPowerProblem OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The input is not qualified to provide power to the system." + ::= { lgpFlexConditionsWellKnown 4122 } + +lgpCondId4132BypassOverloadPhaseA OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An overload exists on output phase A while operating on the bypass." + ::= { lgpFlexConditionsWellKnown 4132 } + +lgpCondId4133BypassOverloadPhaseB OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An overload exists on output phase B while operating on the bypass." + ::= { lgpFlexConditionsWellKnown 4133 } + +lgpCondId4134BypassOverloadPhaseC OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An overload exists on output phase C while operating on the bypass." + ::= { lgpFlexConditionsWellKnown 4134 } + +lgpCondId4135BypassNotAvailable OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A problem associated with the bypass has been detected." + ::= { lgpFlexConditionsWellKnown 4135 } + +lgpCondId4137BypassAutoRetransferPrimed OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Automatic retransfer from bypass to inverter is possible." + ::= { lgpFlexConditionsWellKnown 4137 } + +lgpCondId4138BypassAutoRetransferFailed OBJECT-IDENTITY + STATUS current + DESCRIPTION + "After performing a recoverable transfer to bypass, an attempt to + auto retransfer from bypass to inverter failed." + ::= { lgpFlexConditionsWellKnown 4138 } + +lgpCondId4139BypassExcessAutoRetransfers OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The number of auto retransfers, from bypass to inverter, has + exceeded the maximum for a specified time interval." + ::= { lgpFlexConditionsWellKnown 4139 } + +lgpCondId4140BypassRestartInhibitExternal OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Restart of the bypass is inhibited by the state of an external + signal." + ::= { lgpFlexConditionsWellKnown 4140 } + +lgpCondId4141BypassBreakerClosed OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The bypass breaker is closed." + ::= { lgpFlexConditionsWellKnown 4141 } + +lgpCondId4142BypassStaticSwitchOverload OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Bypass off due to static switch overload." + ::= { lgpFlexConditionsWellKnown 4142 } + +lgpCondId4143BypassStaticSwitchUnavailable OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The static bypass is unavailable to support the critical load." + ::= { lgpFlexConditionsWellKnown 4143 } + +lgpCondId4144BypassExcessivePulseParallel OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has performed too many pulse parallel operations within + a specified time interval." + ::= { lgpFlexConditionsWellKnown 4144 } + +lgpCondId4145BypassAutoTransferFailed OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An automatic transfer to static bypass failed." + ::= { lgpFlexConditionsWellKnown 4145 } + +lgpCondId4146SystemInputPhsRotationError OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The power conductors on the input line are not wired to the UPS in + the sequence preferred for the rectifier (A-B-C)." + ::= { lgpFlexConditionsWellKnown 4146 } + +lgpCondId4147SystemInputCurrentLimit OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The RMS input current has reached the input current limit + threshold." + ::= { lgpFlexConditionsWellKnown 4147 } + +lgpCondId4162BatteryLow OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The calculated battery time remaining has reached the low battery + threshold." + ::= { lgpFlexConditionsWellKnown 4162 } + +lgpCondId4163OutputOffEndofDischarge OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Output turned off due to battery reaching end-of-discharge." + ::= { lgpFlexConditionsWellKnown 4163 } + +lgpCondId4164BatteryChargingError OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The battery is not charging properly." + ::= { lgpFlexConditionsWellKnown 4164 } + +lgpCondId4165BatteryChargingReducedExtrnl OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Using a reduced battery charging algorithm due to an external + signal." + ::= { lgpFlexConditionsWellKnown 4165 } + +lgpCondId4166BatteryCapacityLow OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery capacity is low." + ::= { lgpFlexConditionsWellKnown 4166 } + +lgpCondId4167OutputOff OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Output is off." + ::= { lgpFlexConditionsWellKnown 4167 } + +lgpCondId4168BatteryDischarging OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The battery is discharging." + ::= { lgpFlexConditionsWellKnown 4168 } + +lgpCondId4169BatteryTemperatureImbalance OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Excessive temperature differences between battery sensors detected." + ::= { lgpFlexConditionsWellKnown 4169 } + +lgpCondId4170BatteryEqualize OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The rectifier output voltage is increased to equalize the battery + voltage level." + ::= { lgpFlexConditionsWellKnown 4170 } + +lgpCondId4171BatteryManualTestInProgress OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Manual battery test is in progress." + ::= { lgpFlexConditionsWellKnown 4171 } + +lgpCondId4172BatteryAutoTestInProgress OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Automatic battery test is in progress." + ::= { lgpFlexConditionsWellKnown 4172 } + +lgpCondId4173MainBatteryDisconnectOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Main battery disconnect is open." + ::= { lgpFlexConditionsWellKnown 4173 } + +lgpCondId4174BatteryTemperatureSensorFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A battery temperature sensor fault has been detected." + ::= { lgpFlexConditionsWellKnown 4174 } + +lgpCondId4175BypassFrequencyError OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The bypass frequency is outside the inverter synchronization + limits." + ::= { lgpFlexConditionsWellKnown 4175 } + +lgpCondId4176BatteryCircuitBreaker1Open OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 1 is open." + ::= { lgpFlexConditionsWellKnown 4176 } + +lgpCondId4177BatteryBreaker1OpenFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 1 failed to open." + ::= { lgpFlexConditionsWellKnown 4177 } + +lgpCondId4178BatteryBreaker1CloseFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 1 failed to close." + ::= { lgpFlexConditionsWellKnown 4178 } + +lgpCondId4179BatteryCircuitBreaker2Open OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 2 is open." + ::= { lgpFlexConditionsWellKnown 4179 } + +lgpCondId4180BatteryBreaker2OpenFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 2 failed to open." + ::= { lgpFlexConditionsWellKnown 4180 } + +lgpCondId4181BatteryBreaker2CloseFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 2 failed to close." + ::= { lgpFlexConditionsWellKnown 4181 } + +lgpCondId4182BatteryCircuitBreaker3Open OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 3 is open." + ::= { lgpFlexConditionsWellKnown 4182 } + +lgpCondId4183BatteryBreaker3OpenFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 3 failed to open." + ::= { lgpFlexConditionsWellKnown 4183 } + +lgpCondId4184BatteryBreaker3CloseFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 3 failed to close." + ::= { lgpFlexConditionsWellKnown 4184 } + +lgpCondId4185BatteryCircuitBreaker4Open OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 4 is open." + ::= { lgpFlexConditionsWellKnown 4185 } + +lgpCondId4186BatteryBreaker4OpenFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 4 failed to open." + ::= { lgpFlexConditionsWellKnown 4186 } + +lgpCondId4187BatteryBreaker4CloseFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 4 failed to close." + ::= { lgpFlexConditionsWellKnown 4187 } + +lgpCondId4188BatteryCircuitBreaker5Open OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 5 is open." + ::= { lgpFlexConditionsWellKnown 4188 } + +lgpCondId4189BatteryBreaker5OpenFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 5 failed to open." + ::= { lgpFlexConditionsWellKnown 4189 } + +lgpCondId4190BatteryBreaker5CloseFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 5 failed to close." + ::= { lgpFlexConditionsWellKnown 4190 } + +lgpCondId4191BatteryCircuitBreaker6Open OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 6 is open." + ::= { lgpFlexConditionsWellKnown 4191 } + +lgpCondId4192BatteryBreaker6OpenFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 6 failed to open." + ::= { lgpFlexConditionsWellKnown 4192 } + +lgpCondId4193BatteryBreaker6CloseFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 6 failed to close." + ::= { lgpFlexConditionsWellKnown 4193 } + +lgpCondId4194BatteryCircuitBreaker7Open OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 7 is open." + ::= { lgpFlexConditionsWellKnown 4194 } + +lgpCondId4195BatteryBreaker7OpenFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 7 failed to open." + ::= { lgpFlexConditionsWellKnown 4195 } + +lgpCondId4196BatteryBreaker7CloseFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 7 failed to close." + ::= { lgpFlexConditionsWellKnown 4196 } + +lgpCondId4197BatteryCircuitBreaker8Open OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 8 is open." + ::= { lgpFlexConditionsWellKnown 4197 } + +lgpCondId4198BatteryBreaker8OpenFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 8 failed to open." + ::= { lgpFlexConditionsWellKnown 4198 } + +lgpCondId4199BatteryBreaker8CloseFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery circuit breaker 8 failed to close." + ::= { lgpFlexConditionsWellKnown 4199 } + +lgpCondId4200BatteryChargingInhibited OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery charging is inhibited due to an external inhibit signal." + ::= { lgpFlexConditionsWellKnown 4200 } + +lgpCondId4213SystemShutdownEPO OBJECT-IDENTITY + STATUS current + DESCRIPTION + "System shutdown due to Emergency Power Off (EPO)." + ::= { lgpFlexConditionsWellKnown 4213 } + +lgpCondId4214SystemShutdownREPO OBJECT-IDENTITY + STATUS current + DESCRIPTION + "System shutdown due to Remote Emergency Power Off (REPO)." + ::= { lgpFlexConditionsWellKnown 4214 } + +lgpCondId4215SystemOutputOff OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system output is off." + ::= { lgpFlexConditionsWellKnown 4215 } + +lgpCondId4216BypassBackfeedDetected OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system detected a voltage on the bypass when none was expected." + ::= { lgpFlexConditionsWellKnown 4216 } + +lgpCondId4217BypassManualXfrInhibited OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Manual transfer from inverter to bypass is inhibited - bypass not + qualified." + ::= { lgpFlexConditionsWellKnown 4217 } + +lgpCondId4218BypassManualRexfrInhibited OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Manual transfer from bypass to inverter is inhibited - inverter + output not qualified." + ::= { lgpFlexConditionsWellKnown 4218 } + +lgpCondId4219BatteryOverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A battery temperature sensor is reporting a value above a + threshold." + ::= { lgpFlexConditionsWellKnown 4219 } + +lgpCondId4220BatteryExternalMonitor1 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "External battery monitor 1 - battery maintenance required." + ::= { lgpFlexConditionsWellKnown 4220 } + +lgpCondId4221BatteryExternalMonitor2 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "External battery monitor 2 - battery maintenance required." + ::= { lgpFlexConditionsWellKnown 4221 } + +lgpCondId4222BatteryGroundFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery system ground fault amperage exceeds the threshold." + ::= { lgpFlexConditionsWellKnown 4222 } + +lgpCondId4229EmergencyPowerOffLatched OBJECT-IDENTITY + STATUS current + DESCRIPTION + "System output is off - 'Emergency Power Off (EPO) - latched' + requires manual reset." + ::= { lgpFlexConditionsWellKnown 4229 } + +lgpCondId4230SystemOutputLowPowerFactor OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system output power factor is low, resulting in reduced output + capacity." + ::= { lgpFlexConditionsWellKnown 4230 } + +lgpCondId4231OutputCurrentExceedsThreshold OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Output current for one or more phases exceeds a threshold." + ::= { lgpFlexConditionsWellKnown 4231 } + +lgpCondId4233InverterFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Inverter failure - inverter output is off." + ::= { lgpFlexConditionsWellKnown 4233 } + +lgpCondId4234InverterOverloadPhaseA OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Inverter is operating with an overload on phase A." + ::= { lgpFlexConditionsWellKnown 4234 } + +lgpCondId4235InverterOverloadPhaseB OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Inverter is operating with an overload on phase B." + ::= { lgpFlexConditionsWellKnown 4235 } + +lgpCondId4236InverterOverloadPhaseC OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Inverter is operating with an overload on phase C." + ::= { lgpFlexConditionsWellKnown 4236 } + +lgpCondId4237InverterInhibitExternal OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Restart of the inverter is inhibited by an external signal." + ::= { lgpFlexConditionsWellKnown 4237 } + +lgpCondId4238InverterOutBreakerOpenFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Inverter output breaker failed to open." + ::= { lgpFlexConditionsWellKnown 4238 } + +lgpCondId4239InverterOutBreakerCloseFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Inverter output breaker failed to close." + ::= { lgpFlexConditionsWellKnown 4239 } + +lgpCondId4270InputContact01 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external input contact 1." + ::= { lgpFlexConditionsWellKnown 4270 } + +lgpCondId4271InputContact02 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external input contact 2." + ::= { lgpFlexConditionsWellKnown 4271 } + +lgpCondId4272InputContact03 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external input contact 3." + ::= { lgpFlexConditionsWellKnown 4272 } + +lgpCondId4273InputContact04 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external input contact 4." + ::= { lgpFlexConditionsWellKnown 4273 } + +lgpCondId4274InputContact05 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external input contact 5." + ::= { lgpFlexConditionsWellKnown 4274 } + +lgpCondId4275InputContact06 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external input contact 6." + ::= { lgpFlexConditionsWellKnown 4275 } + +lgpCondId4276InputContact07 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external input contact 7." + ::= { lgpFlexConditionsWellKnown 4276 } + +lgpCondId4277InputContact08 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external input contact 8." + ::= { lgpFlexConditionsWellKnown 4277 } + +lgpCondId4278InputContact09 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external input contact 9." + ::= { lgpFlexConditionsWellKnown 4278 } + +lgpCondId4279InputContact10 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external input contact 10." + ::= { lgpFlexConditionsWellKnown 4279 } + +lgpCondId4280InputContact11 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external input contact 11." + ::= { lgpFlexConditionsWellKnown 4280 } + +lgpCondId4281InputContact12 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external input contact 12." + ::= { lgpFlexConditionsWellKnown 4281 } + +lgpCondId4282InputContact13 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external input contact 13." + ::= { lgpFlexConditionsWellKnown 4282 } + +lgpCondId4283InputContact14 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external input contact 14." + ::= { lgpFlexConditionsWellKnown 4283 } + +lgpCondId4284InputContact15 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external input contact 15." + ::= { lgpFlexConditionsWellKnown 4284 } + +lgpCondId4285InputContact16 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external input contact 16." + ::= { lgpFlexConditionsWellKnown 4285 } + +lgpCondId4286OutputAmpOverUserLimitPhsA OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The phase A output has exceeded the user amperage threshold." + ::= { lgpFlexConditionsWellKnown 4286 } + +lgpCondId4287OutputAmpOverUserLimitPhsB OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The phase B output has exceeded the user amperage threshold." + ::= { lgpFlexConditionsWellKnown 4287 } + +lgpCondId4288OutputAmpOverUserLimitPhsC OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The phase C output has exceeded the user amperage threshold." + ::= { lgpFlexConditionsWellKnown 4288 } + +lgpCondId4289InverterTransferInhibitExt OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Transfer of critical bus source to inverter is inhibited by an + external signal." + ::= { lgpFlexConditionsWellKnown 4289 } + +lgpCondId4290InverterShutdownOverload OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The inverter has shutdown due to a sustained overload." + ::= { lgpFlexConditionsWellKnown 4290 } + +lgpCondId4294InletAirOverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The inlet air exceeds the maximum temperature threshold." + ::= { lgpFlexConditionsWellKnown 4294 } + +lgpCondId4295RectifierFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Rectifier failure - rectifier is off." + ::= { lgpFlexConditionsWellKnown 4295 } + +lgpCondId4296RectifierOperationInhibitExt OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The operation of the rectifier is inhibited by an external signal." + ::= { lgpFlexConditionsWellKnown 4296 } + +lgpCondId4297UPSOutputonInverter OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The output power is supplied by the inverter." + ::= { lgpFlexConditionsWellKnown 4297 } + +lgpCondId4298UPSOutputonBypass OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The output power is supplied by the bypass." + ::= { lgpFlexConditionsWellKnown 4298 } + +lgpCondId4299OutputLoadonMaintBypass OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The output power is supplied by the maintenance bypass." + ::= { lgpFlexConditionsWellKnown 4299 } + +lgpCondId4300InternalCommunicationsFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The control has detected a communication failure of a component on + the internal communication bus." + ::= { lgpFlexConditionsWellKnown 4300 } + +lgpCondId4308DCBusGroundFaultPositive OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A ground fault has been detected on the positive DC Bus link." + ::= { lgpFlexConditionsWellKnown 4308 } + +lgpCondId4309DCBusGroundFaultNegative OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A ground fault has been detected on the negative DC Bus link." + ::= { lgpFlexConditionsWellKnown 4309 } + +lgpCondId4310EquipmentOverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Equipment over temperature summary event." + ::= { lgpFlexConditionsWellKnown 4310 } + +lgpCondId4311SystemFanFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "System fan failure - one or more fans have failed." + ::= { lgpFlexConditionsWellKnown 4311 } + +lgpCondId4313PasswordChanged OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Password changed." + ::= { lgpFlexConditionsWellKnown 4313 } + +lgpCondId4314PowerSupplyFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Power supply failure." + ::= { lgpFlexConditionsWellKnown 4314 } + +lgpCondId4315OnGenerator OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A generator is supplying the power to the system." + ::= { lgpFlexConditionsWellKnown 4315 } + +lgpCondId4316AutoRestartInProgress OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Auto restart is in progress." + ::= { lgpFlexConditionsWellKnown 4316 } + +lgpCondId4317AutoRestartInhibitedExt OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Auto restart inhibited due to an external signal." + ::= { lgpFlexConditionsWellKnown 4317 } + +lgpCondId4320InitiatedTransfertoBypass OBJECT-IDENTITY + STATUS current + DESCRIPTION + "User initiated manual transfer to bypass." + ::= { lgpFlexConditionsWellKnown 4320 } + +lgpCondId4321InitiatedTransfertoInverter OBJECT-IDENTITY + STATUS current + DESCRIPTION + "User initiated manual transfer to inverter." + ::= { lgpFlexConditionsWellKnown 4321 } + +lgpCondId4322BatteryTestPassed OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery test passed." + ::= { lgpFlexConditionsWellKnown 4322 } + +lgpCondId4323BatteryTestFailed OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery test failed." + ::= { lgpFlexConditionsWellKnown 4323 } + +lgpCondId4324BatteryTestManuallyStopped OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The battery test was manually stopped prior to completion." + ::= { lgpFlexConditionsWellKnown 4324 } + +lgpCondId4325BackfeedBreakerOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The backfeed breaker is in the open position." + ::= { lgpFlexConditionsWellKnown 4325 } + +lgpCondId4341VelocityAuthenticationFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Notification of a message rejected by Velocity due to an + authentication failure." + ::= { lgpFlexConditionsWellKnown 4341 } + +lgpCondId4360ReceptacleOverCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a receptacle over current condition." + ::= { lgpFlexConditionsWellKnown 4360 } + +lgpCondId4361ReceptacleUnderCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a receptacle under current condition." + ::= { lgpFlexConditionsWellKnown 4361 } + +lgpCondId4382SystemInputCurrentImbalance OBJECT-IDENTITY + STATUS current + DESCRIPTION + "System Input Currents are Imbalanced." + ::= { lgpFlexConditionsWellKnown 4382 } + +lgpCondId4383BypassStaticSwitchOffExtrnl OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Bypass static switch is off due to the state of an external signal." + ::= { lgpFlexConditionsWellKnown 4383 } + +lgpCondId4384BatteryEoDDisconnect OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery disconnect due to end-of-discharge." + ::= { lgpFlexConditionsWellKnown 4384 } + +lgpCondId4389SystemOutputFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A fault has been detected in the system output." + ::= { lgpFlexConditionsWellKnown 4389 } + +lgpCondId4390InverterOffExternal OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Inverter is off (operation is inhibited) due to external signal + state." + ::= { lgpFlexConditionsWellKnown 4390 } + +lgpCondId4391InverterStaticSwitchSCRShort OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a short across one or more inverter static + switch Silicon Controlled Rectifiers (SCR)." + ::= { lgpFlexConditionsWellKnown 4391 } + +lgpCondId4392TemperatureSensorError OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more temperature sensors cannot provide a valid temperature + reading (i.e. sensor failure, wiring failure, sense circuit + failure, etc)." + ::= { lgpFlexConditionsWellKnown 4392 } + +lgpCondId4406BranchOverCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module over current condition." + ::= { lgpFlexConditionsWellKnown 4406 } + +lgpCondId4407BranchUnderCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module under current condition." + ::= { lgpFlexConditionsWellKnown 4407 } + +lgpCondId4416BranchOverCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module over current condition." + ::= { lgpFlexConditionsWellKnown 4416 } + +lgpCondId4417BranchUnderCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module under current condition." + ::= { lgpFlexConditionsWellKnown 4417 } + +lgpCondId4421BranchFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more conditions indicate a Branch Receptacle Module failure + , service is required." + ::= { lgpFlexConditionsWellKnown 4421 } + +lgpCondId4436PDUOverCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module over current condition." + ::= { lgpFlexConditionsWellKnown 4436 } + +lgpCondId4437PDUUnderCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module under current condition." + ::= { lgpFlexConditionsWellKnown 4437 } + +lgpCondId4438SystemInternalTemperatureRise OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Excessive temperature rise internal to the system (i.e. difference + between the output versus input temperature is too large)." + ::= { lgpFlexConditionsWellKnown 4438 } + +lgpCondId4439AutomaticRestartFailed OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Automatic restart failed." + ::= { lgpFlexConditionsWellKnown 4439 } + +lgpCondId4440FuseFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A summary event indicating one or more fuse failures." + ::= { lgpFlexConditionsWellKnown 4440 } + +lgpCondId4441SystemControllerError OBJECT-IDENTITY + STATUS current + DESCRIPTION + "System controller internal error." + ::= { lgpFlexConditionsWellKnown 4441 } + +lgpCondId4442SystemBreakersOpenFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more breakers in the system failed to open." + ::= { lgpFlexConditionsWellKnown 4442 } + +lgpCondId4448PDUOverCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module over current condition." + ::= { lgpFlexConditionsWellKnown 4448 } + +lgpCondId4449PDUUnderCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module under current condition." + ::= { lgpFlexConditionsWellKnown 4449 } + +lgpCondId4468PDUOverCurrentL1 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module over current condition on line 1." + ::= { lgpFlexConditionsWellKnown 4468 } + +lgpCondId4469PDUOverCurrentL2 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module over current condition on line 2." + ::= { lgpFlexConditionsWellKnown 4469 } + +lgpCondId4470PDUOverCurrentL3 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module over current condition on line 3." + ::= { lgpFlexConditionsWellKnown 4470 } + +lgpCondId4471PDUUnderCurrentL1 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module under current condition on line 1." + ::= { lgpFlexConditionsWellKnown 4471 } + +lgpCondId4472PDUUnderCurrentL2 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module under current condition on line 2." + ::= { lgpFlexConditionsWellKnown 4472 } + +lgpCondId4473PDUUnderCurrentL3 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module under current condition on line 3." + ::= { lgpFlexConditionsWellKnown 4473 } + +lgpCondId4492ReceptaclePowerStateOn OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The receptacle power state changed to the ON state." + ::= { lgpFlexConditionsWellKnown 4492 } + +lgpCondId4493ReceptaclePowerStateOff OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The receptacle power state changed to the OFF state." + ::= { lgpFlexConditionsWellKnown 4493 } + +lgpCondId4494BranchBreakerOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Branch Receptacle Module's input breaker is open." + ::= { lgpFlexConditionsWellKnown 4494 } + +lgpCondId4495DeviceConfigurationChange OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Device Configuration Change." + ::= { lgpFlexConditionsWellKnown 4495 } + +lgpCondId4496BasicDisplayModuleRemoved OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Basic Display Module Removed." + ::= { lgpFlexConditionsWellKnown 4496 } + +lgpCondId4497BasicDisplayModuleDiscovered OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Basic Display Module Discovered." + ::= { lgpFlexConditionsWellKnown 4497 } + +lgpCondId4500PDUOverCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a power module over current condition." + ::= { lgpFlexConditionsWellKnown 4500 } + +lgpCondId4501PDUUnderCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a power module under current condition." + ::= { lgpFlexConditionsWellKnown 4501 } + +lgpCondId4502PDUFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more conditions indicate a power module failure, service is + required." + ::= { lgpFlexConditionsWellKnown 4502 } + +lgpCondId4503PDUCommunicationFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Internal communications failure with the Power Module." + ::= { lgpFlexConditionsWellKnown 4503 } + +lgpCondId4504BranchRemoved OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Branch Receptacle Module Removed." + ::= { lgpFlexConditionsWellKnown 4504 } + +lgpCondId4505BranchDiscovered OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Branch Receptacle Module Discovered." + ::= { lgpFlexConditionsWellKnown 4505 } + +lgpCondId4506BranchOverCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a Branch Receptacle Module over current + condition." + ::= { lgpFlexConditionsWellKnown 4506 } + +lgpCondId4507BranchCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a Branch Receptacle Module under current + condition." + ::= { lgpFlexConditionsWellKnown 4507 } + +lgpCondId4508ReceptacleLoadRemoved OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The receptacle's load stopped drawing power." + ::= { lgpFlexConditionsWellKnown 4508 } + +lgpCondId4509ReceptacleLoadAdded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The receptacle's load started to draw power." + ::= { lgpFlexConditionsWellKnown 4509 } + +lgpCondId4523ModuleRemoved OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Module Removed." + ::= { lgpFlexConditionsWellKnown 4523 } + +lgpCondId4524ModuleAdded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Module Added." + ::= { lgpFlexConditionsWellKnown 4524 } + +lgpCondId4550FirmwareUpdateRequired OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Module compatibility error requires a system firmware update to + resolve." + ::= { lgpFlexConditionsWellKnown 4550 } + +lgpCondId4551GenericTestEvent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A generic test event designed to evaluate system handling of + events." + ::= { lgpFlexConditionsWellKnown 4551 } + +lgpCondId4580OverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An over temperature condition was detected." + ::= { lgpFlexConditionsWellKnown 4580 } + +lgpCondId4581UnderTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An under temperature condition was detected." + ::= { lgpFlexConditionsWellKnown 4581 } + +lgpCondId4588OverRelativeHumidity OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An over relative humidity condition was detected." + ::= { lgpFlexConditionsWellKnown 4588 } + +lgpCondId4589UnderRelativeHumidity OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An under relative humidity condition was detected." + ::= { lgpFlexConditionsWellKnown 4589 } + +lgpCondId4601ExternalAirSensorAOverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Ext Air Sensor A Temperature] has exceeded [External Air Over + Temp Threshold]." + ::= { lgpFlexConditionsWellKnown 4601 } + +lgpCondId4604ExternalAirSensorBOverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Ext Air Sensor B Temperature] has exceeded [External Air Over + Temp Threshold]." + ::= { lgpFlexConditionsWellKnown 4604 } + +lgpCondId4608ExtAirSensorAUnderTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Ext Air Sensor A Temperature] has dropped below [Ext Air Under + Temp Threshold]." + ::= { lgpFlexConditionsWellKnown 4608 } + +lgpCondId4611ExtAirSensorBUnderTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Ext Air Sensor B Temperature] has dropped below [Ext Air Under + Temp Threshold]." + ::= { lgpFlexConditionsWellKnown 4611 } + +lgpCondId4615ExtDewPointOverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "At least one dew point temperature reading ([Ext Air Sensor A Dew + Point Temp], [Ext Air Sensor B Dew Point Temp]...) has exceeded + [Ext Dew Point Over Temp Threshold]." + ::= { lgpFlexConditionsWellKnown 4615 } + +lgpCondId4618ExternalAirSensorAIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external air sensor A is disconnected or the signal is out of + range." + ::= { lgpFlexConditionsWellKnown 4618 } + +lgpCondId4621ExternalAirSensorBIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external air sensor B is disconnected or the signal is out of + range." + ::= { lgpFlexConditionsWellKnown 4621 } + +lgpCondId4626SupplyChilledWaterOverTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Supply Fluid Temperature] has exceeded [High Supply Fluid + Temperature Threshold]." + ::= { lgpFlexConditionsWellKnown 4626 } + +lgpCondId4629SupplyChilledWaterTempSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The supply chilled water temperature sensor is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 4629 } + +lgpCondId4634SupplyRefrigerantOverTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Event that is activated when [Supply Refrigerant Temperature] + exceeds [Supply Refrig Over Temp Threshold]. The event is + deactivated when the temperature drops below the threshold." + ::= { lgpFlexConditionsWellKnown 4634 } + +lgpCondId4637SupplyRefrigerantUnderTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Supply Refrigerant Temperature] has dropped below a specified + threshold." + ::= { lgpFlexConditionsWellKnown 4637 } + +lgpCondId4640SupplyRefrigerantTempSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The supply refrigeramt temperature sensor is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 4640 } + +lgpCondId4645SupplyFluidOverTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Supply Fluid Temperature] has exceeded [Supply Fluid Over Temp + Threshold]." + ::= { lgpFlexConditionsWellKnown 4645 } + +lgpCondId4648SupplyFluidUnderTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Supply Fluid Temperature] has dropped below a specified threshold." + ::= { lgpFlexConditionsWellKnown 4648 } + +lgpCondId4651SupplyFluidTempSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The supply fluid temperature sensor is disconnected or the signal + is out of range." + ::= { lgpFlexConditionsWellKnown 4651 } + +lgpCondId4656Pump1LossofFlow OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Loss of flow is detected in pump 1. The loss of flow condition + occurs when no differential pressure is detected across the pump." + ::= { lgpFlexConditionsWellKnown 4656 } + +lgpCondId4659Pump2LossofFlow OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Loss of flow is detected in pump 2. The loss of flow condition + occurs when no differential pressure is detected across the pump." + ::= { lgpFlexConditionsWellKnown 4659 } + +lgpCondId4662PumpShortCycle OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Pumps have short cycled. A short cycle is defined as turning on + and off a number of times over a set time period." + ::= { lgpFlexConditionsWellKnown 4662 } + +lgpCondId4669Compressor1AHighHeadPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor 1A high head pressure." + ::= { lgpFlexConditionsWellKnown 4669 } + +lgpCondId4672Compressor1BHighHeadPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor 1B high head pressure." + ::= { lgpFlexConditionsWellKnown 4672 } + +lgpCondId4675Compressor2AHighHeadPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor 2A high head pressure." + ::= { lgpFlexConditionsWellKnown 4675 } + +lgpCondId4678Compressor2BHighHeadPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor 2B high head pressure." + ::= { lgpFlexConditionsWellKnown 4678 } + +lgpCondId4681Compressor1AShortCycle OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor 1A short cycle. A short cycle is defined as turning on + and off a number of times over a set time period." + ::= { lgpFlexConditionsWellKnown 4681 } + +lgpCondId4684Compressor1BShortCycle OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor 1B short cycle. A short cycle is defined as turning on + and off a number of times over a set time period." + ::= { lgpFlexConditionsWellKnown 4684 } + +lgpCondId4687Compressor2AShortCycle OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor 2A short cycle. A short cycle is defined as turning on + and off a number of times over a set time period." + ::= { lgpFlexConditionsWellKnown 4687 } + +lgpCondId4690Compressor2BShortCycle OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor 2B short cycle. A short cycle is defined as turning on + and off a number of times over a set time period." + ::= { lgpFlexConditionsWellKnown 4690 } + +lgpCondId4693Tandem1LowSuctionPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "'Tandem compressors' 1 low suction pressure." + ::= { lgpFlexConditionsWellKnown 4693 } + +lgpCondId4696Tandem2LowSuctionPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "'Tandem compressors' 2 low suction pressure." + ::= { lgpFlexConditionsWellKnown 4696 } + +lgpCondId4703ChilledWaterControlValvePosition OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Chilled water valve out of position. Chilled water control valve + position does not match expected value." + ::= { lgpFlexConditionsWellKnown 4703 } + +lgpCondId4711SystemCondensationDetected OBJECT-IDENTITY + STATUS current + DESCRIPTION + "System condensation detected." + ::= { lgpFlexConditionsWellKnown 4711 } + +lgpCondId4714ShutdownLossOfPower OBJECT-IDENTITY + STATUS current + DESCRIPTION + "System lost power. This event becomes active when the unit is + powered on following an unexpected loss of power." + ::= { lgpFlexConditionsWellKnown 4714 } + +lgpCondId4720SmokeDetected OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Smoke detected." + ::= { lgpFlexConditionsWellKnown 4720 } + +lgpCondId4723WaterUnderFloor OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Water under the floor is detected." + ::= { lgpFlexConditionsWellKnown 4723 } + +lgpCondId4726ServiceRequired OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Unit requires servicing." + ::= { lgpFlexConditionsWellKnown 4726 } + +lgpCondId4729FanIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more fans are not operating within their operational + parameters." + ::= { lgpFlexConditionsWellKnown 4729 } + +lgpCondId4732ReceptacleLoadDropped OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The receptacle's load is not drawing power." + ::= { lgpFlexConditionsWellKnown 4732 } + +lgpCondId4740BatteryAutomaticTestInhibited OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Automatic (scheduled) battery tests are inhibited." + ::= { lgpFlexConditionsWellKnown 4740 } + +lgpCondId4741BatterySelfTest OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery self test is in progress." + ::= { lgpFlexConditionsWellKnown 4741 } + +lgpCondId4742BatteryLowShutdown OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery disconnect due to end-of-discharge." + ::= { lgpFlexConditionsWellKnown 4742 } + +lgpCondId4747EquipmentTemperatureSensorFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more temperature sensors report a temperature outside of + the range of expected operation." + ::= { lgpFlexConditionsWellKnown 4747 } + +lgpCondId4749SystemFanFailureRedundant OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Redundant system fan failure." + ::= { lgpFlexConditionsWellKnown 4749 } + +lgpCondId4750MultipleFanFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Multiple fan failure." + ::= { lgpFlexConditionsWellKnown 4750 } + +lgpCondId4753MainControllerFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A Main Controller fault has been detected." + ::= { lgpFlexConditionsWellKnown 4753 } + +lgpCondId4754SystemBreakersCloseFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more breakers in the system failed to close." + ::= { lgpFlexConditionsWellKnown 4754 } + +lgpCondId4755InputFilterCycleLock OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The input filter disconnect is open due to exceeding the maximum + number of cycles." + ::= { lgpFlexConditionsWellKnown 4755 } + +lgpCondId4756ServiceCodeActive OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Service code is running." + ::= { lgpFlexConditionsWellKnown 4756 } + +lgpCondId4757LBSActive OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Load Bus Sync option is active." + ::= { lgpFlexConditionsWellKnown 4757 } + +lgpCondId4758LBSInhibited OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected that conditions to perform Load Bus Sync + are not satisfied." + ::= { lgpFlexConditionsWellKnown 4758 } + +lgpCondId4759LeadingPowerFactor OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The leading output Power Factor has fallen below a specified value." + ::= { lgpFlexConditionsWellKnown 4759 } + +lgpCondId4760ControlsResetRequired OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A controls reset is required due to one or more critical settings + changing." + ::= { lgpFlexConditionsWellKnown 4760 } + +lgpCondId4823ParallelCommWarning OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Parallel communication bus warning." + ::= { lgpFlexConditionsWellKnown 4823 } + +lgpCondId4824SystemCommFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Failure of a device on the multi-module system communication bus." + ::= { lgpFlexConditionsWellKnown 4824 } + +lgpCondId4825LossofRedundancy OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The multi-module collection doesn't have enough modules to satisfy + the redundancy configuration." + ::= { lgpFlexConditionsWellKnown 4825 } + +lgpCondId4826BPSSStartupInhibit OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Bypass Static Switch startup is inhibited." + ::= { lgpFlexConditionsWellKnown 4826 } + +lgpCondId4827MMSTransferInhibit OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The critical load can not be manually transferred from inverter to + bypass." + ::= { lgpFlexConditionsWellKnown 4827 } + +lgpCondId4828MMSRetransferInhibit OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The critical load can not be manually retransferred from bypass to + inverter." + ::= { lgpFlexConditionsWellKnown 4828 } + +lgpCondId4830MMSLossofSyncPulse OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Multi-module system loss of sync pulse." + ::= { lgpFlexConditionsWellKnown 4830 } + +lgpCondId4831MMSOverload OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Multi-module system overload." + ::= { lgpFlexConditionsWellKnown 4831 } + +lgpCondId4834MMSOnBattery OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The multi-module system is on battery." + ::= { lgpFlexConditionsWellKnown 4834 } + +lgpCondId4835MMSLowBatteryWarning OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Multi-module system low battery warning." + ::= { lgpFlexConditionsWellKnown 4835 } + +lgpCondId4906LowAmbientTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a low ambient temperature condition." + ::= { lgpFlexConditionsWellKnown 4906 } + +lgpCondId4907HighAmbientTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a high ambient temperature condition." + ::= { lgpFlexConditionsWellKnown 4907 } + +lgpCondId4908LowOverallVoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a low battery string overall voltage + condition." + ::= { lgpFlexConditionsWellKnown 4908 } + +lgpCondId4909HighOverallVoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a high battery string overall voltage + condition." + ::= { lgpFlexConditionsWellKnown 4909 } + +lgpCondId4910HighBatteryStringCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a high battery string current condition." + ::= { lgpFlexConditionsWellKnown 4910 } + +lgpCondId4911LowBatteryStringFloatCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a low battery string float current + condition." + ::= { lgpFlexConditionsWellKnown 4911 } + +lgpCondId4912HighBatteryStringFloatCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a high battery string float current + condition." + ::= { lgpFlexConditionsWellKnown 4912 } + +lgpCondId4913HighBatteryStringRippleCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a high battery string ripple current + condition." + ::= { lgpFlexConditionsWellKnown 4913 } + +lgpCondId4914BatteryStringDischargeDetected OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a battery string discharge condition." + ::= { lgpFlexConditionsWellKnown 4914 } + +lgpCondId4915MaximumDischargeTimeExceeded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected an excessive discharge time condition." + ::= { lgpFlexConditionsWellKnown 4915 } + +lgpCondId4916DischargeLowOverallVoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a low battery string overall voltage + condition during a discharge." + ::= { lgpFlexConditionsWellKnown 4916 } + +lgpCondId4917DischargeLowCellVoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a low cell voltage condition during a + discharge." + ::= { lgpFlexConditionsWellKnown 4917 } + +lgpCondId4918DischargeHighBatteryStringCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a high battery string current condition + during a discharge." + ::= { lgpFlexConditionsWellKnown 4918 } + +lgpCondId4919ExcessiveCelltoCellTemperatureDeviation OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected an excessive cell to cell temperature + deviation condition." + ::= { lgpFlexConditionsWellKnown 4919 } + +lgpCondId4920ExcessiveCelltoAmbientTemperatureDeviation OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected an excessive cell to ambient temperature + deviation condition." + ::= { lgpFlexConditionsWellKnown 4920 } + +lgpCondId4964LowCellVoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a low cell voltage condition." + ::= { lgpFlexConditionsWellKnown 4964 } + +lgpCondId4965HighCellVoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a high cell voltage condition." + ::= { lgpFlexConditionsWellKnown 4965 } + +lgpCondId4966LowCellTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a low cell temperature condition." + ::= { lgpFlexConditionsWellKnown 4966 } + +lgpCondId4967HighCellTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a high cell temperature condition." + ::= { lgpFlexConditionsWellKnown 4967 } + +lgpCondId4968LowInternalResistance OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a low internal resistance condition." + ::= { lgpFlexConditionsWellKnown 4968 } + +lgpCondId4969HighInternalResistance OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a high internal resistance condition." + ::= { lgpFlexConditionsWellKnown 4969 } + +lgpCondId4970HighIntercellResistance OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a high intercell resistance condition." + ::= { lgpFlexConditionsWellKnown 4970 } + +lgpCondId4978IntertierResistanceHigh OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a high intertier resistance condition." + ::= { lgpFlexConditionsWellKnown 4978 } + +lgpCondId4980SupplyChilledWaterLossofFlow OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Supply chilled water or glycol flow is too low." + ::= { lgpFlexConditionsWellKnown 4980 } + +lgpCondId4983SupplyRefrigOverTempBand1 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Supply Refrigerant Temperature] is above the upper threshold + specified by [Supply Refrig Temp Band 1]." + ::= { lgpFlexConditionsWellKnown 4983 } + +lgpCondId4986SupplyRefrigUnderTempBand1 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Supply Refrigerant Temperature] is below the lower threshold + specified by [Supply Refrig Temp Band 1]." + ::= { lgpFlexConditionsWellKnown 4986 } + +lgpCondId4990SupplyRefrigOverTempBand2 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Supply Refrigerant Temperature] is above the upper threshold + specified by [Supply Refrig Temp Band 2]." + ::= { lgpFlexConditionsWellKnown 4990 } + +lgpCondId4993SupplyRefrigUnderTempBand2 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Supply Refrigerant Temperature] is below the lower threshold + specified by [Supply Refrig Temp Band 2]." + ::= { lgpFlexConditionsWellKnown 4993 } + +lgpCondId4996Inverter1ShortCycle OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Inverter for pump 1 has short cycled and is temporarily locked out + from further operation to protect from thermal overload. A short + cycle is defined as powering on and off a number of times over a + set time period." + ::= { lgpFlexConditionsWellKnown 4996 } + +lgpCondId4999Inverter2ShortCycle OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Inverter for pump 2 has short cycled and is temporarily locked out + from further operation to protect from thermal overload. A short + cycle is defined as powering on and off a number of times over a + set time period." + ::= { lgpFlexConditionsWellKnown 4999 } + +lgpCondId5015SupplyAirOverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Supply Air Temperature] has exceeded [High Supply Air Temperature + Threshold]." + ::= { lgpFlexConditionsWellKnown 5015 } + +lgpCondId5019SupplyAirUnderTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Supply Air Temperature] has dropped below [Low Supply Air + Temperature Threshold]." + ::= { lgpFlexConditionsWellKnown 5019 } + +lgpCondId5023ReturnAirOverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Return Air Temperature] has exceeded [High Return Air Temperature + Threshold]." + ::= { lgpFlexConditionsWellKnown 5023 } + +lgpCondId5026SupplyAirSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The air sensor at the outlet of the unit is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 5026 } + +lgpCondId5034HighReturnHumidity OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Return Humidity] has exceeded [High Return Humidity Threshold]." + ::= { lgpFlexConditionsWellKnown 5034 } + +lgpCondId5036LowReturnHumidity OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Return Humidity] has dropped below [Low Return Humidity + Threshold]." + ::= { lgpFlexConditionsWellKnown 5036 } + +lgpCondId5037HumidifierHoursExceeded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Operating hours for the humidifier have exceeded the threshold." + ::= { lgpFlexConditionsWellKnown 5037 } + +lgpCondId5038DehumidifierHoursExceeded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Operating hours for the dehumidifier have exceeded the threshold." + ::= { lgpFlexConditionsWellKnown 5038 } + +lgpCondId5039HumidifierUnderCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The electrical current to the humidifier has dropped below its + lower threshold." + ::= { lgpFlexConditionsWellKnown 5039 } + +lgpCondId5040HumidifierOverCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The electrical current to the humidifier has exceeded its upper + threshold." + ::= { lgpFlexConditionsWellKnown 5040 } + +lgpCondId5041HumidifierLowWater OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The water level in the humidifier has dropped below its threshold." + ::= { lgpFlexConditionsWellKnown 5041 } + +lgpCondId5042HumidifierCylinderWorn OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Humidifier cylinder is not operating properly and needs to be + replaced." + ::= { lgpFlexConditionsWellKnown 5042 } + +lgpCondId5043HumidifierIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Humidifier issue detected, causing it to be locked out." + ::= { lgpFlexConditionsWellKnown 5043 } + +lgpCondId5044ExtHumidifierLockout OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The humidifier is shut down and disabled by an external input + signal." + ::= { lgpFlexConditionsWellKnown 5044 } + +lgpCondId5045HumidifierControlBoardNotDetected OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Humidifier control board is required to be connected, but no + signal is detected." + ::= { lgpFlexConditionsWellKnown 5045 } + +lgpCondId5046ReturnHumidityOutOfProportionalBand OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Return Humidity] has exceeded the upper limit of + [Dehumidification Proportional Band], or has dropped below the + lower limit of [Humidification Proportional Band] ], for an + extended period of time." + ::= { lgpFlexConditionsWellKnown 5046 } + +lgpCondId5053LossofAirFlow OBJECT-IDENTITY + STATUS current + DESCRIPTION + "No air flow through the unit due to failure of all fans." + ::= { lgpFlexConditionsWellKnown 5053 } + +lgpCondId5054FanHoursExceeded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Operating hours for the unit blower fan have exceeded the + threshold." + ::= { lgpFlexConditionsWellKnown 5054 } + +lgpCondId5055TopFanIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The top fan is not operating within its normal parameters." + ::= { lgpFlexConditionsWellKnown 5055 } + +lgpCondId5056BottomFanIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The bottom fan is not operating within its normal parameters." + ::= { lgpFlexConditionsWellKnown 5056 } + +lgpCondId5060RemoteSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Remote sensor is disconnected or the signal is out of range." + ::= { lgpFlexConditionsWellKnown 5060 } + +lgpCondId5062Compressor1LowSuctionPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor 1 low suction pressure." + ::= { lgpFlexConditionsWellKnown 5062 } + +lgpCondId5063Compressor1HoursExceeded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Operating hours for compressor 1 have exceeded the threshold." + ::= { lgpFlexConditionsWellKnown 5063 } + +lgpCondId5064DigScrollComp1TempSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Digital scroll compressor 1 temperature sensor is disconnected or + the signal is out of range." + ::= { lgpFlexConditionsWellKnown 5064 } + +lgpCondId5065DigScrollComp1OverTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Digital scroll compressor 1 shut off because its head temperature + has exceeded the upper threshold." + ::= { lgpFlexConditionsWellKnown 5065 } + +lgpCondId5066Compressor1LowPressureTransducerIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor 1 low pressure transducer is disconnected or the signal + is out of range." + ::= { lgpFlexConditionsWellKnown 5066 } + +lgpCondId5067ExtCompressorLockout OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The compressor is shut down and disabled by an external input + signal." + ::= { lgpFlexConditionsWellKnown 5067 } + +lgpCondId5068ReheaterOverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The temperature of the reheater has exceeded its threshold." + ::= { lgpFlexConditionsWellKnown 5068 } + +lgpCondId5069ElectricReheater1HoursExceeded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Operating hours for electric reheater 1 have exceeded the + threshold." + ::= { lgpFlexConditionsWellKnown 5069 } + +lgpCondId5070ExtReheatLockout OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The reheater is shut down and disabled by an external input signal." + ::= { lgpFlexConditionsWellKnown 5070 } + +lgpCondId5071Condenser1Issue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Condenser 1 is not operating within its normal parameters." + ::= { lgpFlexConditionsWellKnown 5071 } + +lgpCondId5072CondenserVFDIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The condenser fan Variable Frequency Drive is offline." + ::= { lgpFlexConditionsWellKnown 5072 } + +lgpCondId5073CondenserTVSSIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The condenser Transient Voltage Surge Suppressor or Surge + Protection Device has failed." + ::= { lgpFlexConditionsWellKnown 5073 } + +lgpCondId5104ExtOverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A temperature has exceeded its threshold, as indicated by an + external input signal." + ::= { lgpFlexConditionsWellKnown 5104 } + +lgpCondId5105ExtLossofFlow OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Loss of flow is detected, as indicated by an external input signal." + ::= { lgpFlexConditionsWellKnown 5105 } + +lgpCondId5106ExtCondenserPumpHighWater OBJECT-IDENTITY + STATUS current + DESCRIPTION + "High water is detected in the condensate pump by the auxiliary + float, as indicated by an external input signal." + ::= { lgpFlexConditionsWellKnown 5106 } + +lgpCondId5107ExtStandbyGlycolPumpOn OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The standby glycol pump is on, as indicated by an external input + signal." + ::= { lgpFlexConditionsWellKnown 5107 } + +lgpCondId5108ExternalFireDetected OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Fire detected, as indicated by an external input signal." + ::= { lgpFlexConditionsWellKnown 5108 } + +lgpCondId5109UnitOn OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Unit was turned on." + ::= { lgpFlexConditionsWellKnown 5109 } + +lgpCondId5110UnitOff OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Unit was turned off." + ::= { lgpFlexConditionsWellKnown 5110 } + +lgpCondId5111UnitStandby OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Unit was placed in standby mode." + ::= { lgpFlexConditionsWellKnown 5111 } + +lgpCondId5112UnitPartialShutdown OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An event has occurred requiring some system components to be + shutdown and disabled." + ::= { lgpFlexConditionsWellKnown 5112 } + +lgpCondId5113UnitShutdown OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An event has occurred requiring the unit to be shutdown and + disabled to prevent damage to the system." + ::= { lgpFlexConditionsWellKnown 5113 } + +lgpCondId5114WaterLeakageDetectorSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The water leakage detector sensor is disconnected or the signal is + out of range." + ::= { lgpFlexConditionsWellKnown 5114 } + +lgpCondId5115BMSCommunicationsTimeout OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Building Management System (or external monitoring system) has not + communicated with the system within the expected timeframe." + ::= { lgpFlexConditionsWellKnown 5115 } + +lgpCondId5116MaintenanceDue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The calculated maintenance date has been reached." + ::= { lgpFlexConditionsWellKnown 5116 } + +lgpCondId5117MaintenanceCompleted OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Maintenance has been completed on the unit." + ::= { lgpFlexConditionsWellKnown 5117 } + +lgpCondId5118CloggedAirFilter OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Air filter is dirty and needs to be (cleaned or) replaced." + ::= { lgpFlexConditionsWellKnown 5118 } + +lgpCondId5119RAMBatteryIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "RAM or RAM backup battery is not operating correctly." + ::= { lgpFlexConditionsWellKnown 5119 } + +lgpCondId5120MasterUnitCommunicationLost OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Communication with master unit has been lost." + ::= { lgpFlexConditionsWellKnown 5120 } + +lgpCondId5121HighPowerShutdown OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Supply to high power components has been shutdown." + ::= { lgpFlexConditionsWellKnown 5121 } + +lgpCondId5126DigScrollComp2OverTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Digital scroll compressor 2 shut off because its head temperature + has exceeded the upper threshold." + ::= { lgpFlexConditionsWellKnown 5126 } + +lgpCondId5144OutputOfUf OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The output frequency has exceeded a specified range for a + specified period of time." + ::= { lgpFlexConditionsWellKnown 5144 } + +lgpCondId5145MMSModuleAlarmActive OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Active alarm or fault of any module in a multi-module system." + ::= { lgpFlexConditionsWellKnown 5145 } + +lgpCondId5146CompressorPumpDownIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Unable to pump down suction-side pressure during compressor + shutdown." + ::= { lgpFlexConditionsWellKnown 5146 } + +lgpCondId5147ReturnAirSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The air sensor at the inlet of the unit is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 5147 } + +lgpCondId5148CompressorHighPressureTransducerIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor high pressure transducer is disconnected or the signal + is out of range." + ::= { lgpFlexConditionsWellKnown 5148 } + +lgpCondId5149BatteryNotQualified OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The UPS battery voltage is not qualified. This event will be + detected even in the absence of battery disconnect or when it is + open." + ::= { lgpFlexConditionsWellKnown 5149 } + +lgpCondId5150BatteryTerminalsReversed OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The measured battery voltage is a negative value due to reverse + battery terminal connections." + ::= { lgpFlexConditionsWellKnown 5150 } + +lgpCondId5151BatteryConverterFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery converter failure. This is a summary event caused by one + or more power sub-modules in a UPS module." + ::= { lgpFlexConditionsWellKnown 5151 } + +lgpCondId5152InverterSCROpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected an open across one or more inverter static + switch Silicon Controlled Rectifiers." + ::= { lgpFlexConditionsWellKnown 5152 } + +lgpCondId5153LoadSharingFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Difference between any phase inverter current of unit and the + relevant average output current of parallel system is more than a + specific percent of nominal current." + ::= { lgpFlexConditionsWellKnown 5153 } + +lgpCondId5154DCBusAbnormal OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected an abnormal DC Bus Voltage." + ::= { lgpFlexConditionsWellKnown 5154 } + +lgpCondId5155MainsInputNeutralLost OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Loss of neutral in the input source is detected." + ::= { lgpFlexConditionsWellKnown 5155 } + +lgpCondId5156LoadImpactTransfer OBJECT-IDENTITY + STATUS current + DESCRIPTION + "On bypass as result of load impact." + ::= { lgpFlexConditionsWellKnown 5156 } + +lgpCondId5157UserOperationInvalid OBJECT-IDENTITY + STATUS current + DESCRIPTION + "User attempted an invalid operation." + ::= { lgpFlexConditionsWellKnown 5157 } + +lgpCondId5158PowerSubModuleFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more failures detected in power module, inverter or + rectifier." + ::= { lgpFlexConditionsWellKnown 5158 } + +lgpCondId5178OutputOvervoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more of the output phase voltages has exceeded the limit." + ::= { lgpFlexConditionsWellKnown 5178 } + +lgpCondId5179OutputUndervoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more of the output phase voltages has dropped below the + limit." + ::= { lgpFlexConditionsWellKnown 5179 } + +lgpCondId5180OutputOvercurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more of the phase currents has exceeded the limit." + ::= { lgpFlexConditionsWellKnown 5180 } + +lgpCondId5181NeutralOvercurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system's neutral current has exceeded the limit." + ::= { lgpFlexConditionsWellKnown 5181 } + +lgpCondId5182GroundOvercurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "System ground current has exceeded the limit." + ::= { lgpFlexConditionsWellKnown 5182 } + +lgpCondId5183OutputVoltageTHD OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Total Harmonic Distortion of the voltage on one or more of the + output phases has exceeded the limit." + ::= { lgpFlexConditionsWellKnown 5183 } + +lgpCondId5184OutputFrequencyError OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The output frequency is outside a specified range." + ::= { lgpFlexConditionsWellKnown 5184 } + +lgpCondId5185TransformerOvertemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Indicates a unit transformer overtemperature condition." + ::= { lgpFlexConditionsWellKnown 5185 } + +lgpCondId5212PanelSummaryStatus OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The status for the panel. Detects and annunciates upon occurrence + of any branch or panelboard main breaker active event." + ::= { lgpFlexConditionsWellKnown 5212 } + +lgpCondId5213PanelOvervoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more of the phase voltages of this panel has exceeded the + limit." + ::= { lgpFlexConditionsWellKnown 5213 } + +lgpCondId5214PanelUndervoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more of the phase voltages of this panel is less than the + limit." + ::= { lgpFlexConditionsWellKnown 5214 } + +lgpCondId5215PanelOvercurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more of the phase currents of this panel has exceeded the + limit." + ::= { lgpFlexConditionsWellKnown 5215 } + +lgpCondId5216PanelNeutralOvercurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Neutral current of this panel has exceeded the limit." + ::= { lgpFlexConditionsWellKnown 5216 } + +lgpCondId5217PanelGroundOvercurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Ground current of this panel has exceeded the limit." + ::= { lgpFlexConditionsWellKnown 5217 } + +lgpCondId5226BranchOvercurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The current in one or more phases of this branch exceeds the limit." + ::= { lgpFlexConditionsWellKnown 5226 } + +lgpCondId5227BranchUndercurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The current in one or more phases of this branch is less than the + limit." + ::= { lgpFlexConditionsWellKnown 5227 } + +lgpCondId5245SubfeedPhaseOvercurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more of the phase currents in this subfeed has exceeded the + limit." + ::= { lgpFlexConditionsWellKnown 5245 } + +lgpCondId5246SubfeedNeutralOvercurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Neutral current in this subfeed has exceeded the limit." + ::= { lgpFlexConditionsWellKnown 5246 } + +lgpCondId5247SubfeedGroundOvercurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Ground current of this subfeed has exceeded the limit." + ::= { lgpFlexConditionsWellKnown 5247 } + +lgpCondId5249EventState OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The present state of this digital event input." + ::= { lgpFlexConditionsWellKnown 5249 } + +lgpCondId5263CompressorNotStopping OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor commanded to stop, but continues to run." + ::= { lgpFlexConditionsWellKnown 5263 } + +lgpCondId5269CompressorHoursExceeded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Compressor Hours] has exceeded [Compressor Hours Threshold]." + ::= { lgpFlexConditionsWellKnown 5269 } + +lgpCondId5270CompressorHighHeadPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor is shut down due to high head pressure." + ::= { lgpFlexConditionsWellKnown 5270 } + +lgpCondId5271CompressorLowSuctionPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor is shut down due to low suction pressure." + ::= { lgpFlexConditionsWellKnown 5271 } + +lgpCondId5272CompressorThermalOverload OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor is shut down due to thermal overload." + ::= { lgpFlexConditionsWellKnown 5272 } + +lgpCondId5273CompressorLowOilPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor low oil pressure." + ::= { lgpFlexConditionsWellKnown 5273 } + +lgpCondId5274CompressorHeadPressureOverThreshold OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor head pressure has exceeded an upper threshold." + ::= { lgpFlexConditionsWellKnown 5274 } + +lgpCondId5275CompressorLossofDifferentialPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor is shut down due to low differential pressure." + ::= { lgpFlexConditionsWellKnown 5275 } + +lgpCondId5277CondenserFanIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Condenser fan is not operating within its operational parameters." + ::= { lgpFlexConditionsWellKnown 5277 } + +lgpCondId5278LowCondenserRefrigerantPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Refrigerant pressure in condenser coil is too low." + ::= { lgpFlexConditionsWellKnown 5278 } + +lgpCondId5280LowFluidPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Fluid Pressure] has dropped below a specified threshold." + ::= { lgpFlexConditionsWellKnown 5280 } + +lgpCondId5293ReturnFluidOverTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Return Fluid Temperature] has exceeded a specified threshold." + ::= { lgpFlexConditionsWellKnown 5293 } + +lgpCondId5294ReturnFluidUnderTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Return Fluid Temperature] has dropped below a specified threshold." + ::= { lgpFlexConditionsWellKnown 5294 } + +lgpCondId5295ReturnFluidTempSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The return fluid temperature sensor is disconnected or the signal + is out of range." + ::= { lgpFlexConditionsWellKnown 5295 } + +lgpCondId5296TeamworkReturnFluidTempSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The return fluid temperature sensors for all Teamwork units are + disconnected or the signals are out of range." + ::= { lgpFlexConditionsWellKnown 5296 } + +lgpCondId5297AllPumpsLossofFlow OBJECT-IDENTITY + STATUS current + DESCRIPTION + "System is shut down due to loss of flow in all available pumps." + ::= { lgpFlexConditionsWellKnown 5297 } + +lgpCondId5300PumpHoursExceeded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Pump Hours] has exceeded [Pump Hours Threshold]." + ::= { lgpFlexConditionsWellKnown 5300 } + +lgpCondId5306FreeCoolingValveHoursExceeded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Free Cooling Valve Hours] has exceeded [Free Cooling Valve Hours + Threshold]." + ::= { lgpFlexConditionsWellKnown 5306 } + +lgpCondId5308EvaporatorInletTempSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The evaporator inlet temperature sensor is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 5308 } + +lgpCondId5309TeamworkEvaporatorInletTempSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The evaporator inlet temperature sensors for all Teamwork units + are disconnected or the signals are out of range." + ::= { lgpFlexConditionsWellKnown 5309 } + +lgpCondId5310EvaporatorFluidFreezeAutoReset OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Evaporator outlet fluid temperature has dropped below the freeze + threshold. Evaporator has been shut down, but will restart when + the temperature rises above the threshold." + ::= { lgpFlexConditionsWellKnown 5310 } + +lgpCondId5311EvaporatorFluidFreezeManualResetRequired OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Evaporator outlet fluid temperature has dropped below the freeze + threshold. Evaporator has been shut down and requires a manual + reset." + ::= { lgpFlexConditionsWellKnown 5311 } + +lgpCondId5315SubgroupEventOccurredDuringCommunicationLoss OBJECT-IDENTITY + STATUS current + DESCRIPTION + "While subgroup unit communication was lost, an event occurred on + the subgroup unit. Please check subgroup unit event log." + ::= { lgpFlexConditionsWellKnown 5315 } + +lgpCondId5335ReturnAirUnderTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Return Air Temperature] has dropped below [Low Return Air + Temperature Threshold]." + ::= { lgpFlexConditionsWellKnown 5335 } + +lgpCondId5349ExtAirSensorAHighHumidity OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Ext Air Sensor A Humidity] has exceeded [Ext Air Sensor A High + Humidity Threshold]." + ::= { lgpFlexConditionsWellKnown 5349 } + +lgpCondId5351ExtAirSensorALowHumidity OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Ext Air Sensor A Humidity] has dropped below [Ext Air Sensor A + Low Humidity Threshold]." + ::= { lgpFlexConditionsWellKnown 5351 } + +lgpCondId5352CompressorShortCycle OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor short cycle. A short cycle is defined as turning on and + off a number of times over a set time period." + ::= { lgpFlexConditionsWellKnown 5352 } + +lgpCondId5354DigScrollCompDischargeTempSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Digital scroll compressor discharge temperature sensor is + disconnected or the signal is out of range." + ::= { lgpFlexConditionsWellKnown 5354 } + +lgpCondId5355DigScrollCompOverTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Digital scroll compressor is shut down due to head temperature + exceeding an upper threshold." + ::= { lgpFlexConditionsWellKnown 5355 } + +lgpCondId5361ExtFreeCoolingLockout OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Free cooling is disabled by an external input signal." + ::= { lgpFlexConditionsWellKnown 5361 } + +lgpCondId5362FreeCoolingTempSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The free cooling fluid temperature sensor is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 5362 } + +lgpCondId5365HotWaterHotGasValveHoursExceeded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Hot Water / Hot Gas Valve Hours] has exceeded [Hot Water / Hot + Gas Valve Hours Threshold]." + ::= { lgpFlexConditionsWellKnown 5365 } + +lgpCondId5368ElectricReheaterHoursExceeded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Electric Reheater Hours] has exceeded [Electric Reheaters Hours + Threshold]." + ::= { lgpFlexConditionsWellKnown 5368 } + +lgpCondId5376MainFanOverload OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Main fan is shut down due to thermal overload." + ::= { lgpFlexConditionsWellKnown 5376 } + +lgpCondId5377Condenser OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Condenser is not operating within its operational parameters." + ::= { lgpFlexConditionsWellKnown 5377 } + +lgpCondId5415ExtLossofAirBlower OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Loss of air blower is detected, as indicated by an external input + signal." + ::= { lgpFlexConditionsWellKnown 5415 } + +lgpCondId5416ExtStandbyUnitOn OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Standby unit is on, as indicated by an external input signal." + ::= { lgpFlexConditionsWellKnown 5416 } + +lgpCondId5417DigitalOutputBoardNotDetected OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Digital output board is required to be connected, but no signal is + detected." + ::= { lgpFlexConditionsWellKnown 5417 } + +lgpCondId5418UnitCodeMissing OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Unit code has not been entered and saved." + ::= { lgpFlexConditionsWellKnown 5418 } + +lgpCondId5419UnitCommunicationLost OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Master has lost communication with one or more networked units." + ::= { lgpFlexConditionsWellKnown 5419 } + +lgpCondId5422OvertemperaturePowerOff OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Power turned off because equipment over temperature limit." + ::= { lgpFlexConditionsWellKnown 5422 } + +lgpCondId5423TooManySensors OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The number of sensors connected to the PDU exceeds the allowable + limit." + ::= { lgpFlexConditionsWellKnown 5423 } + +lgpCondId5432TransformerOvertemperaturePowerOff OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Output power shutdown due to high transformer temperature." + ::= { lgpFlexConditionsWellKnown 5432 } + +lgpCondId5433TransformerOvertemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Transformer temperature has exceeded the limit." + ::= { lgpFlexConditionsWellKnown 5433 } + +lgpCondId5434TransformerTemperatureSensorFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Transformer temperature sensor has failed." + ::= { lgpFlexConditionsWellKnown 5434 } + +lgpCondId5436LowAmbientTemperatureProbeTwo OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a low ambient temperature condition on + temperature probe 2." + ::= { lgpFlexConditionsWellKnown 5436 } + +lgpCondId5437HighAmbientTemperatureProbeTwo OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a high ambient temperature condition on + temperature probe 2." + ::= { lgpFlexConditionsWellKnown 5437 } + +lgpCondId5438ThermalRunawayDetected OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a thermal runaway condition." + ::= { lgpFlexConditionsWellKnown 5438 } + +lgpCondId5439BatteryStringEqualize OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a battery string equalize condition." + ::= { lgpFlexConditionsWellKnown 5439 } + +lgpCondId5440BatteryStringOffline OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected the battery string is offline." + ::= { lgpFlexConditionsWellKnown 5440 } + +lgpCondId5442DischargeLowCellVoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a low cell voltage condition during a + discharge." + ::= { lgpFlexConditionsWellKnown 5442 } + +lgpCondId5447MMSPowerSharing OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A module is not sharing power with the other modules in a multi + -module system." + ::= { lgpFlexConditionsWellKnown 5447 } + +lgpCondId5453ModuleInStandbyIntelligentParalleling OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Module is placed into standby operation per Intelligent + Paralleling." + ::= { lgpFlexConditionsWellKnown 5453 } + +lgpCondId5456ECOModeActive OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Conditions for Activation or Automatic Reactivation have been + satisfied." + ::= { lgpFlexConditionsWellKnown 5456 } + +lgpCondId5457ECOModeSuspended OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ECO Mode session is suspended." + ::= { lgpFlexConditionsWellKnown 5457 } + +lgpCondId5458ExcessECOSuspends OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Number of automatic suspensions has exceeded the ECO Mode - + Maximum Auto Suspensions setting." + ::= { lgpFlexConditionsWellKnown 5458 } + +lgpCondId5471DoorOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An open door was detected." + ::= { lgpFlexConditionsWellKnown 5471 } + +lgpCondId5472DoorSensorDisconnected OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Door sensor disconnect detected." + ::= { lgpFlexConditionsWellKnown 5472 } + +lgpCondId5479ContactClosureOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An open circuit was detected." + ::= { lgpFlexConditionsWellKnown 5479 } + +lgpCondId5480ContactClosureClosed OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A closed circuit was detected." + ::= { lgpFlexConditionsWellKnown 5480 } + +lgpCondId5492ExtSystemCondensationDetected OBJECT-IDENTITY + STATUS current + DESCRIPTION + "External system condensation detected." + ::= { lgpFlexConditionsWellKnown 5492 } + +lgpCondId5495ExtFanIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more fans are not operating within their operational + parameters." + ::= { lgpFlexConditionsWellKnown 5495 } + +lgpCondId5500ExtRemoteShutdown OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Unit is shut down by a remote signal." + ::= { lgpFlexConditionsWellKnown 5500 } + +lgpCondId5505HotAisleTempOutofRange OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The air temperature in the Hot aisle is either above [Hot Aisle + Over Temp Threshold] or below [Hot Aisle Under Temp Threshold]." + ::= { lgpFlexConditionsWellKnown 5505 } + +lgpCondId5508ColdAisleTempOutofRange OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The air temperature in the cold aisle is either above [Cold Aisle + Over Temp Threshold] or below [Cold Aisle Under Temp Threshold]." + ::= { lgpFlexConditionsWellKnown 5508 } + +lgpCondId5512RemoteShutdown OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Unit is shut down by a remote signal." + ::= { lgpFlexConditionsWellKnown 5512 } + +lgpCondId5513CompressorCapacityReduced OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor capacity has been reduced." + ::= { lgpFlexConditionsWellKnown 5513 } + +lgpCondId5514CompressorLowPressureTransducerIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor low pressure transducer is disconnected or the signal + is out of range." + ::= { lgpFlexConditionsWellKnown 5514 } + +lgpCondId5524PDUNeutralOverCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a neutral over current condition." + ::= { lgpFlexConditionsWellKnown 5524 } + +lgpCondId5531CondenserCommunicationLost OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Communication with condenser unit has been lost." + ::= { lgpFlexConditionsWellKnown 5531 } + +lgpCondId5535CondenserOutsideAirTempSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Condenser outside air temperature sensor is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 5535 } + +lgpCondId5536CondenserOutsideAirTempOutofOperatingRange OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Condenser Outside Air Temperature] is either above an upper + threshold or below a lower threshold." + ::= { lgpFlexConditionsWellKnown 5536 } + +lgpCondId5537CondenserControlBoardIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The condenser control board is reporting an issue." + ::= { lgpFlexConditionsWellKnown 5537 } + +lgpCondId5539CondenserRefrigerantPressureOverThreshold OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Condenser refrigerant pressure has exceeded a threshold." + ::= { lgpFlexConditionsWellKnown 5539 } + +lgpCondId5540CondenserRefrigerantPressureUnderThreshold OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Condenser refrigerant pressure has dropped below a threshold." + ::= { lgpFlexConditionsWellKnown 5540 } + +lgpCondId5541CondenserRefrigerantPressureSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Condenser refrigerant pressure sensor is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 5541 } + +lgpCondId5542CondenserSupplyRefrigerantOverTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Condenser supply refrigerant temperature has exceeded a threshold." + ::= { lgpFlexConditionsWellKnown 5542 } + +lgpCondId5543CondenserSupplyRefrigerantUnderTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Condenser supply refrigerant temperature has dropped below a + specified threshold." + ::= { lgpFlexConditionsWellKnown 5543 } + +lgpCondId5544CondenserSupplyRefrigerantTempSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Condenser supply refrigerant temperature sensor is disconnected or + the signal is out of range." + ::= { lgpFlexConditionsWellKnown 5544 } + +lgpCondId5545CondenserMaxFanSpeedOverride OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Fan speed exceeding the maximum set point in order to alleviate a + high temperature or pressure condition." + ::= { lgpFlexConditionsWellKnown 5545 } + +lgpCondId5559EvaporatorReturnFluidOverTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Evaporator Return Fluid Temperature] has exceeded a threshold. + The event is deactivated when the temperature drops below the + threshold." + ::= { lgpFlexConditionsWellKnown 5559 } + +lgpCondId5560EvaporatorReturnFluidUnderTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Evaporator Return Fluid Temperature] has dropped below a + threshold. The event is deactivated when the temperature rises + above the threshold." + ::= { lgpFlexConditionsWellKnown 5560 } + +lgpCondId5561LBSActiveMaster OBJECT-IDENTITY + STATUS current + DESCRIPTION + "This UPS system has been selected as the functional Master Load + Bus Synchronization (LBS) system." + ::= { lgpFlexConditionsWellKnown 5561 } + +lgpCondId5562LBSActiveSlave OBJECT-IDENTITY + STATUS current + DESCRIPTION + "This UPS system is synchronized to the output bus of the UPS + system that has been selected as the Master Load Bus + Synchronization (LBS) system." + ::= { lgpFlexConditionsWellKnown 5562 } + +lgpCondId5563DCBusLowFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The DC Bus voltage has reached a critical low level." + ::= { lgpFlexConditionsWellKnown 5563 } + +lgpCondId5564FanContactorOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The fan contactor is open." + ::= { lgpFlexConditionsWellKnown 5564 } + +lgpCondId5565FanContactorOpenFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The fan contactor failed to open." + ::= { lgpFlexConditionsWellKnown 5565 } + +lgpCondId5566FanContactorCloseFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The fan contactor failed to close." + ::= { lgpFlexConditionsWellKnown 5566 } + +lgpCondId5567IPInhibit OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The intelligent paralleling operation is inhibited." + ::= { lgpFlexConditionsWellKnown 5567 } + +lgpCondId5568InputUndervoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more of the input phase voltages has dropped below the + limit." + ::= { lgpFlexConditionsWellKnown 5568 } + +lgpCondId5569InputOvervoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more of the input phase voltages has exceeded the limit." + ::= { lgpFlexConditionsWellKnown 5569 } + +lgpCondId5573AmbientAirSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Ambient air sensor is disconnected or the signal is out of range." + ::= { lgpFlexConditionsWellKnown 5573 } + +lgpCondId5577ExtDewPointUnderTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "At least one dew point temperature reading ([Ext Air Sensor A Dew + Point Temp], [Ext Air Sensor B Dew Point Temp]...) has dropped + below [Ext Dew Point Under Temp Threshold]." + ::= { lgpFlexConditionsWellKnown 5577 } + +lgpCondId5578DewPointOverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Dew point temperature reading has exceeded the upper threshold." + ::= { lgpFlexConditionsWellKnown 5578 } + +lgpCondId5579DewPointUnderTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Dew point temperature reading has dropped below the lower + threshold." + ::= { lgpFlexConditionsWellKnown 5579 } + +lgpCondId5588UnspecifiedGeneralEvent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more unspecified events active. See local unit display for + further details." + ::= { lgpFlexConditionsWellKnown 5588 } + +lgpCondId5593RemoteSensorAverageOverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Remote Sensor Average Temperature] has exceeded [Remote Sensor + Over Temp Threshold]." + ::= { lgpFlexConditionsWellKnown 5593 } + +lgpCondId5594RemoteSensorAverageUnderTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Remote Sensor Average Temperature] has dropped below [Remote + Sensor Under Temp Threshold]." + ::= { lgpFlexConditionsWellKnown 5594 } + +lgpCondId5595RemoteSensorSystemAverageOverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Remote Sensor System Average Temperature] has exceeded [Remote + Sensor Over Temp Threshold]." + ::= { lgpFlexConditionsWellKnown 5595 } + +lgpCondId5596RemoteSensorSystemAverageUnderTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Remote Sensor System Average Temperature] has dropped below + [Remote Sensor Under Temp Threshold]." + ::= { lgpFlexConditionsWellKnown 5596 } + +lgpCondId5597RemoteSensorOverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Remote Sensor Temperature] has exceeded [Remote Sensor Over Temp + Threshold]." + ::= { lgpFlexConditionsWellKnown 5597 } + +lgpCondId5598RemoteSensorUnderTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Remote Sensor Temperature] has dropped below [Remote Sensor Under + Temp Threshold]." + ::= { lgpFlexConditionsWellKnown 5598 } + +lgpCondId5600AirEconomizerEmergencyOverride OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Indoor room temperature has exceeded its upper threshold and the + outdoor air damper has been opened for emergency cooling." + ::= { lgpFlexConditionsWellKnown 5600 } + +lgpCondId5601AirEconomizerReducedAirflow OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Air economizer filter is dirty and needs to be cleaned or replaced." + ::= { lgpFlexConditionsWellKnown 5601 } + +lgpCondId5604CompressorSuperheatOverThreshold OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor discharge refrigerant superheat temperature has + exceeded an upper threshold." + ::= { lgpFlexConditionsWellKnown 5604 } + +lgpCondId5609ThermalRunawayCelltoAmbientTemperatureEvent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The delta temperature between a cell temperature and the ambient + temperature has exceeded the thermal runaway cell to ambient + temperature threshold." + ::= { lgpFlexConditionsWellKnown 5609 } + +lgpCondId5610ThermalRunawayCelltoCellTemperatureEvent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The delta temperature between two cells has exceeded the thermal + runaway cell to cell temperature threshold." + ::= { lgpFlexConditionsWellKnown 5610 } + +lgpCondId5611ThermalRunawayChargerCurrentLevelOneEvent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Battery-String charger current has exceeded the thermal + runaway charger current level one threshold." + ::= { lgpFlexConditionsWellKnown 5611 } + +lgpCondId5612ThermalRunawayChargerCurrentLevelTwoEvent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Battery-String charger current has exceeded the thermal + runaway charger current level two threshold." + ::= { lgpFlexConditionsWellKnown 5612 } + +lgpCondId5617TemperatureControlSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The air sensor selected for cooling control is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 5617 } + +lgpCondId5621EEVSuperheatBelowThreshold OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Electronic expansion valve refrigerant low superheat event." + ::= { lgpFlexConditionsWellKnown 5621 } + +lgpCondId5622EEVDischargeTempAboveThreshold OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Electronic expansion valve refrigerant high discharge temperature + event." + ::= { lgpFlexConditionsWellKnown 5622 } + +lgpCondId5623EEVBatteryIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Electronic expansion valve battery cannot be recharged and needs + to be replaced." + ::= { lgpFlexConditionsWellKnown 5623 } + +lgpCondId5624EEVPowerIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Electronic expansion valve lost power and is running on battery + backup." + ::= { lgpFlexConditionsWellKnown 5624 } + +lgpCondId5625EEVUnspecifiedGeneralEvent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more unspecified electronic expansion valve events active. + See local unit display for further details." + ::= { lgpFlexConditionsWellKnown 5625 } + +lgpCondId5629StaticPressureSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The static pressure sensor is disconnected or the signal is out of + range." + ::= { lgpFlexConditionsWellKnown 5629 } + +lgpCondId5630HighStaticPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "High static pressure event." + ::= { lgpFlexConditionsWellKnown 5630 } + +lgpCondId5631LowStaticPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Low static pressure event." + ::= { lgpFlexConditionsWellKnown 5631 } + +lgpCondId5636PumpUnspecifiedGeneralEvent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more unspecified pump events active. See local unit display + for further details." + ::= { lgpFlexConditionsWellKnown 5636 } + +lgpCondId5637CondenserUnitUnspecifiedGeneralEvent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more unspecified condenser unit events active. See local + unit display for further details." + ::= { lgpFlexConditionsWellKnown 5637 } + +lgpCondId5638CondenserCircuitUnspecifiedGeneralEvent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more unspecified condenser circuit events active. See local + unit display for further details." + ::= { lgpFlexConditionsWellKnown 5638 } + +lgpCondId5642SFAReservedEvent1 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5642 } + +lgpCondId5643SFAReservedEvent2 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5643 } + +lgpCondId5644SFAReservedEvent3 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5644 } + +lgpCondId5645SFAReservedEvent4 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5645 } + +lgpCondId5646SFAReservedEvent5 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5646 } + +lgpCondId5647SFAReservedEvent6 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5647 } + +lgpCondId5648SFAReservedEvent7 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5648 } + +lgpCondId5649SFAReservedEvent8 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5649 } + +lgpCondId5650SFAReservedEvent9 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5650 } + +lgpCondId5651SFAReservedEvent10 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5651 } + +lgpCondId5652SFAReservedEvent11 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5652 } + +lgpCondId5653SFAReservedEvent12 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5653 } + +lgpCondId5654SFAReservedEvent13 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5654 } + +lgpCondId5655SFAReservedEvent14 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5655 } + +lgpCondId5656SFAReservedEvent15 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5656 } + +lgpCondId5657SFAReservedEvent16 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5657 } + +lgpCondId5658SFAReservedEvent17 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5658 } + +lgpCondId5659SFAReservedEvent18 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5659 } + +lgpCondId5660SFAReservedEvent19 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5660 } + +lgpCondId5661SFAReservedEvent20 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5661 } + +lgpCondId5662SFAReservedEvent21 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5662 } + +lgpCondId5663SFAReservedEvent22 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5663 } + +lgpCondId5664SFAReservedEvent23 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5664 } + +lgpCondId5665SFAReservedEvent24 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5665 } + +lgpCondId5666SFAReservedEvent25 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 5666 } + +lgpCondId5768OutletAirOvertemperatureLimit OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The difference between the outlet air temperature and inlet air + temperature exceeds a specified maximum temperature." + ::= { lgpFlexConditionsWellKnown 5768 } + +lgpCondId5769EMOShutdown OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An Emergency Module Off command has been detected." + ::= { lgpFlexConditionsWellKnown 5769 } + +lgpCondId5770TopOutletFanFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Top outlet fan fault - one or more top outlet fans have failed." + ::= { lgpFlexConditionsWellKnown 5770 } + +lgpCondId5771MMSOverCapacity OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The multi-module system load is larger than the apparent power + limit setting." + ::= { lgpFlexConditionsWellKnown 5771 } + +lgpCondId5773CompressorCapacityNormal OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor has returned to normal load capacity." + ::= { lgpFlexConditionsWellKnown 5773 } + +lgpCondId5774CompressorContactorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor contactor is not closing during compressor startup or + is not opening during compressor shutdown." + ::= { lgpFlexConditionsWellKnown 5774 } + +lgpCondId5775UnitShutdownUnspecifiedGeneralEvent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more unspecified unit shutdown events active. See local + unit display for further details." + ::= { lgpFlexConditionsWellKnown 5775 } + +lgpCondId5776PDULowVoltageLN OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module under voltage condition (LN)." + ::= { lgpFlexConditionsWellKnown 5776 } + +lgpCondId5777PDULowVoltageLL OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module under voltage condition (LL)." + ::= { lgpFlexConditionsWellKnown 5777 } + +lgpCondId5778PDULowVoltageL1L2 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a line-to-line under voltage condition (L1 + -L2)." + ::= { lgpFlexConditionsWellKnown 5778 } + +lgpCondId5779PDULowVoltageL2L3 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a line-to-line under voltage condition (L2 + -L3)." + ::= { lgpFlexConditionsWellKnown 5779 } + +lgpCondId5780PDULowVoltageL3L1 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a line-to-line under voltage condition (L3 + -L1)." + ::= { lgpFlexConditionsWellKnown 5780 } + +lgpCondId5781PDULowVoltageL1N OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a line to neutral under voltage condition + (L1-N)." + ::= { lgpFlexConditionsWellKnown 5781 } + +lgpCondId5782PDULowVoltageL2N OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a line to neutral under voltage condition + (L2-N)." + ::= { lgpFlexConditionsWellKnown 5782 } + +lgpCondId5783PDULowVoltageL3N OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a line to neutral under voltage condition + (L3-N)." + ::= { lgpFlexConditionsWellKnown 5783 } + +lgpCondId5784BranchLowVoltageLN OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module under voltage condition (LN)." + ::= { lgpFlexConditionsWellKnown 5784 } + +lgpCondId5785BranchLowVoltageLL OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module under voltage condition (LL)." + ::= { lgpFlexConditionsWellKnown 5785 } + +lgpCondId5786BranchLowVoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module under voltage condition." + ::= { lgpFlexConditionsWellKnown 5786 } + +lgpCondId5788ContTieActive OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Continuous Power Tie Active." + ::= { lgpFlexConditionsWellKnown 5788 } + +lgpCondId5792UserkWhReset OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The user kWh accumulator was reset to zero by the operator." + ::= { lgpFlexConditionsWellKnown 5792 } + +lgpCondId5796PeakkWReset OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Peak kW was reset." + ::= { lgpFlexConditionsWellKnown 5796 } + +lgpCondId5798BypassOverload OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Bypass overloaded, reduce load immediately." + ::= { lgpFlexConditionsWellKnown 5798 } + +lgpCondId5801LowBatteryShutdownImminent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "If active and guaranteed shutdown is enabled, a low battery + reserve condition exists that will shutdown the UPS." + ::= { lgpFlexConditionsWellKnown 5801 } + +lgpCondId5806OutputOverload OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An overload exists on the output." + ::= { lgpFlexConditionsWellKnown 5806 } + +lgpCondId5807OutputOffPending OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Output off pending - shutdown imminent." + ::= { lgpFlexConditionsWellKnown 5807 } + +lgpCondId5808SystemShutdownOutputShort OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Shutdown was due to a short on the output." + ::= { lgpFlexConditionsWellKnown 5808 } + +lgpCondId5809SystemShutdownLowBattery OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Shutdown was due to a low battery condition." + ::= { lgpFlexConditionsWellKnown 5809 } + +lgpCondId5810SystemShutdownRemoteShutdown OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Shutdown was due to a remote communications shutdown command." + ::= { lgpFlexConditionsWellKnown 5810 } + +lgpCondId5811SystemShutdownHardwareFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Shutdown was due to an externally applied hardware control signal." + ::= { lgpFlexConditionsWellKnown 5811 } + +lgpCondId5817LossofRedundancy OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has an insufficient number of power modules to provide + redundancy." + ::= { lgpFlexConditionsWellKnown 5817 } + +lgpCondId5818PowerModuleFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more conditions indicate a power module failure, service is + required." + ::= { lgpFlexConditionsWellKnown 5818 } + +lgpCondId5819PowerModuleWarning OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more power modules is reporting a warning condition." + ::= { lgpFlexConditionsWellKnown 5819 } + +lgpCondId5838PowerModuleFanFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Power Module has detected a fan fault." + ::= { lgpFlexConditionsWellKnown 5838 } + +lgpCondId5839PowerModuleOverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Power Module has detected an over temperature condition." + ::= { lgpFlexConditionsWellKnown 5839 } + +lgpCondId5840PowerModuleShutdownOverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Power Module has shutdown due to over temperature." + ::= { lgpFlexConditionsWellKnown 5840 } + +lgpCondId5842ChargerModuleFanFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Charger Module has detected a fan fault." + ::= { lgpFlexConditionsWellKnown 5842 } + +lgpCondId5847BatteryModuleTemperatureSensorFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A Battery Module temperature sensor fault has been detected." + ::= { lgpFlexConditionsWellKnown 5847 } + +lgpCondId5848BatteryModuleOverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Battery Module has detected an over temperature condition." + ::= { lgpFlexConditionsWellKnown 5848 } + +lgpCondId5849ReplaceBatteryModule OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Battery Module needs to be replaced." + ::= { lgpFlexConditionsWellKnown 5849 } + +lgpCondId5850SystemShutdownTransformerOverTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "System shutdown due to transformer over temperature." + ::= { lgpFlexConditionsWellKnown 5850 } + +lgpCondId5851MaximumLoadAlarm OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Maximum load alarm indicating load setting has been exceeded." + ::= { lgpFlexConditionsWellKnown 5851 } + +lgpCondId5856BatteryModuleFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more battery modules are reporting a fault condition." + ::= { lgpFlexConditionsWellKnown 5856 } + +lgpCondId5857BatteryModuleWarning OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more battery modules are reporting a warning condition." + ::= { lgpFlexConditionsWellKnown 5857 } + +lgpCondId5862CheckAirFilter OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Please check air filter, it may need to be cleaned or replaced." + ::= { lgpFlexConditionsWellKnown 5862 } + +lgpCondId5863TransformerFanFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The transformer fan has failed." + ::= { lgpFlexConditionsWellKnown 5863 } + +lgpCondId5865NoLoadWarning OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Indicates the UPS has output voltage but the output current is + below a set threshold [No Load Warning Current Threshold] for a + set period of time [No Load Warning Delay]." + ::= { lgpFlexConditionsWellKnown 5865 } + +lgpCondId5871BatteryOverTemperatureLimit OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A battery temperature sensor is reporting a value above a + predetermined limit." + ::= { lgpFlexConditionsWellKnown 5871 } + +lgpCondId5873UnexpectedMainBatteryDisconnectClosure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The main battery disconnect has closed unexpectedly." + ::= { lgpFlexConditionsWellKnown 5873 } + +lgpCondId5874BatteryOverVoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected that the battery voltage has exceeded a + predetermined limit." + ::= { lgpFlexConditionsWellKnown 5874 } + +lgpCondId5875BatteryFuseFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more battery fuse faults has occurred." + ::= { lgpFlexConditionsWellKnown 5875 } + +lgpCondId5878MainBatteryDisconnectForcedToUnlock OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The main battery disconnect is forced to the unlocked state." + ::= { lgpFlexConditionsWellKnown 5878 } + +lgpCondId5879VdcBackfeed OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The voltage between battery and DC bus measurements is out of + tolerance." + ::= { lgpFlexConditionsWellKnown 5879 } + +lgpCondId5880RectifierConfigurationChangeRequest OBJECT-IDENTITY + STATUS current + DESCRIPTION + "This event indicates that the battery is not configured and PFC is + not enabled." + ::= { lgpFlexConditionsWellKnown 5880 } + +lgpCondId5881RegenerationActive OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Regeneration operation is active." + ::= { lgpFlexConditionsWellKnown 5881 } + +lgpCondId5882RegenerationOperationTerminated OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Regeneration operation is not active." + ::= { lgpFlexConditionsWellKnown 5882 } + +lgpCondId5883RegenerationOperationFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Regeneration operation has been terminated due to bypass source + instability or unit misoperation." + ::= { lgpFlexConditionsWellKnown 5883 } + +lgpCondId5884ProgramInputContact01 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "When the signal from [Program Input Contact 01] is active the + function assigned to this contact is executed." + ::= { lgpFlexConditionsWellKnown 5884 } + +lgpCondId5885ProgramInputContact02 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "When the signal from [Program Input Contact 02] is active the + function assigned to this contact is executed." + ::= { lgpFlexConditionsWellKnown 5885 } + +lgpCondId5886ProgramInputContact03 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "When the signal from [Program Input Contact 03] is active the + function assigned to this contact is executed." + ::= { lgpFlexConditionsWellKnown 5886 } + +lgpCondId5887ProgramInputContact04 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "When the signal from [Program Input Contact 04] is active the + function assigned to this contact is executed." + ::= { lgpFlexConditionsWellKnown 5887 } + +lgpCondId5888ProgramInputContact05 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "When the signal from [Program Input Contact 05] is active the + function assigned to this contact is executed." + ::= { lgpFlexConditionsWellKnown 5888 } + +lgpCondId5889ProgramInputContact06 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "When the signal from [Program Input Contact 06] is active the + function assigned to this contact is executed." + ::= { lgpFlexConditionsWellKnown 5889 } + +lgpCondId5890ProgramInputContact07 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "When the signal from [Program Input Contact 07] is active the + function assigned to this contact is executed." + ::= { lgpFlexConditionsWellKnown 5890 } + +lgpCondId5891ProgramInputContact08 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "When the signal from [Program Input Contact 08] is active the + function assigned to this contact is executed." + ::= { lgpFlexConditionsWellKnown 5891 } + +lgpCondId5892ProgramInputContact09 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "When the signal from [Program Input Contact 09] is active the + function assigned to this contact is executed." + ::= { lgpFlexConditionsWellKnown 5892 } + +lgpCondId5893ProgramInputContact10 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "When the signal from [Program Input Contact 10] is active the + function assigned to this contact is executed." + ::= { lgpFlexConditionsWellKnown 5893 } + +lgpCondId5894ProgramInputContact11 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "When the signal from [Program Input Contact 11] is active the + function assigned to this contact is executed." + ::= { lgpFlexConditionsWellKnown 5894 } + +lgpCondId5895ProgramInputContact12 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "When the signal from [Program Input Contact 12] is active the + function assigned to this contact is executed." + ::= { lgpFlexConditionsWellKnown 5895 } + +lgpCondId5896GroundFaultDetected OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a ground fault on a Battery-String." + ::= { lgpFlexConditionsWellKnown 5896 } + +lgpCondId5902ReturnHumiditySensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The humidity sensor at the inlet of the unit is disconnected or + the signal is out of range." + ::= { lgpFlexConditionsWellKnown 5902 } + +lgpCondId5903CompressorLowDifferentialPressureLockout OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor exceeded maximum startup attempts due to low + differential pressure. Compressor is shutdown and has been + disabled." + ::= { lgpFlexConditionsWellKnown 5903 } + +lgpCondId5906AirflowSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Airflow sensor is disconnected or the signal is out of range." + ::= { lgpFlexConditionsWellKnown 5906 } + +lgpCondId5907ExtAirDamperPositionIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Air damper position does not match expected value, as indicated by + an external input signal." + ::= { lgpFlexConditionsWellKnown 5907 } + +lgpCondId5908ExtPowerSourceAFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Unit main power source A failure, as indicated by an external + input signal." + ::= { lgpFlexConditionsWellKnown 5908 } + +lgpCondId5909ExtPowerSourceBFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Unit main power source B failure, as indicated by an external + input signal." + ::= { lgpFlexConditionsWellKnown 5909 } + +lgpCondId5910StaticPressureSensorOutofRange OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Static pressure sensor signal is out of its configured range." + ::= { lgpFlexConditionsWellKnown 5910 } + +lgpCondId5911FluidTemperatureSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The fluid temperature sensor is disconnected or the signal is out + of range." + ::= { lgpFlexConditionsWellKnown 5911 } + +lgpCondId5912FluidFlowSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The fluid flow sensor is disconnected or the signal is out of + range." + ::= { lgpFlexConditionsWellKnown 5912 } + +lgpCondId5914OverDifferentialPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An over differential pressure condition was detected." + ::= { lgpFlexConditionsWellKnown 5914 } + +lgpCondId5915UnderDifferentialPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An under differential pressure condition was detected." + ::= { lgpFlexConditionsWellKnown 5915 } + +lgpCondId5924MixedModeLockout OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Mixed mode has been entered too many times over a rolling time + period and has been temporarily disabled. Mixed mode is defined + as the use of a compressor on one refrigeration circuit and the + use of a refrigerant pump on the other circuit." + ::= { lgpFlexConditionsWellKnown 5924 } + +lgpCondId5928UnbalancedLoadCondition OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a line-to-line unbalanced load condition." + ::= { lgpFlexConditionsWellKnown 5928 } + +lgpCondId5939BranchOverCurrentProtection OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Branch Receptacle Module's over current protection is + triggered." + ::= { lgpFlexConditionsWellKnown 5939 } + +lgpCondId5948BranchLowVoltageLL OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a module under voltage condition (LL)." + ::= { lgpFlexConditionsWellKnown 5948 } + +lgpCondId5957BypassInputVoltageFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected the bypass voltage is unqualified." + ::= { lgpFlexConditionsWellKnown 5957 } + +lgpCondId5958BatteryTemperatureOutofRange OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery temperature is outside of acceptable range." + ::= { lgpFlexConditionsWellKnown 5958 } + +lgpCondId5960InverterOverload OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Inverter in overload fault." + ::= { lgpFlexConditionsWellKnown 5960 } + +lgpCondId5966AuxAirTempDeviceCommunicationLost OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Communication with external auxiliary device providing an air + temperature value has been lost." + ::= { lgpFlexConditionsWellKnown 5966 } + +lgpCondId5967ModbusPowerMeterCommunicationLost OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Communication with Modbus power meter has been lost." + ::= { lgpFlexConditionsWellKnown 5967 } + +lgpCondId5968InverterDesaturation OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Inverter Desaturation." + ::= { lgpFlexConditionsWellKnown 5968 } + +lgpCondId5969GenericDICFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The control board reports a fault - Service required." + ::= { lgpFlexConditionsWellKnown 5969 } + +lgpCondId5970GroundFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An AC phase to ground fault or three phase fault to ground exists + on the output of the UPS." + ::= { lgpFlexConditionsWellKnown 5970 } + +lgpCondId5973InputBreakerOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The main input breaker is open." + ::= { lgpFlexConditionsWellKnown 5973 } + +lgpCondId5974NeutralBreakerOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The neutral breaker is open." + ::= { lgpFlexConditionsWellKnown 5974 } + +lgpCondId5975OutputBreakerOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The output breaker is open." + ::= { lgpFlexConditionsWellKnown 5975 } + +lgpCondId5976MaintenanceBypassBreakerClosed OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The maintenance bypass breaker is closed." + ::= { lgpFlexConditionsWellKnown 5976 } + +lgpCondId5977BatteryBreakerOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The battery circuit is open." + ::= { lgpFlexConditionsWellKnown 5977 } + +lgpCondId5978RectifierIsolationBreakerRFBOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The rectifier isolation breaker (RFB) indicates that it is in the + open position." + ::= { lgpFlexConditionsWellKnown 5978 } + +lgpCondId5982BypassBreakerSBBOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The bypass circuit breaker (SBB) indicates that it is in the open + position." + ::= { lgpFlexConditionsWellKnown 5982 } + +lgpCondId5983BypassIsolationBreakerBIBOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The bypass isolation breaker (BIB) indicates that it is in the + open position." + ::= { lgpFlexConditionsWellKnown 5983 } + +lgpCondId5984BypassUndervoltageWarning OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The voltage on one or more bypass phases is less than a specified + percentage of the nominal voltage." + ::= { lgpFlexConditionsWellKnown 5984 } + +lgpCondId5985BypassStaticSwitchBPSSOn OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Bypass Static Switch has been turned on." + ::= { lgpFlexConditionsWellKnown 5985 } + +lgpCondId5998BattOvtempWarning OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A battery temperature sensor is reporting a value above the + setpoint." + ::= { lgpFlexConditionsWellKnown 5998 } + +lgpCondId6009InverterOutputBreakerOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The inverter output breaker indicates that it is in the open + position." + ::= { lgpFlexConditionsWellKnown 6009 } + +lgpCondId6011EquipmentOverTempWarning OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Equipment over temperature warning is a summary event based on the + detection of at least one measured temperature exceeding a + threshold." + ::= { lgpFlexConditionsWellKnown 6011 } + +lgpCondId6012EquipmentOvertemperatureLimit OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The equipment air temperature has exceeded its maximum set point." + ::= { lgpFlexConditionsWellKnown 6012 } + +lgpCondId6045RectifierInputBreakerOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The rectifier isolation breaker indicates that it is in the open + position." + ::= { lgpFlexConditionsWellKnown 6045 } + +lgpCondId6046LoadonUPS OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The output is being supplied power from the inverter." + ::= { lgpFlexConditionsWellKnown 6046 } + +lgpCondId6047Core2CoreFuseFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Core-2-core fuse failure." + ::= { lgpFlexConditionsWellKnown 6047 } + +lgpCondId6052SystemOutputBreakerOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system output breaker is open." + ::= { lgpFlexConditionsWellKnown 6052 } + +lgpCondId6059InverterRelayFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The inverter relay has malfunctioned." + ::= { lgpFlexConditionsWellKnown 6059 } + +lgpCondId6060TransfertoBypassSystemOverload OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The UPS System has transferred to bypass because the active power + modules cannot support the critical load." + ::= { lgpFlexConditionsWellKnown 6060 } + +lgpCondId6061InputSourceBackfeed OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The battery is backfeeding the input source." + ::= { lgpFlexConditionsWellKnown 6061 } + +lgpCondId6062LossofSynchronization OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The inverter and bypass are no longer synchronized. ." + ::= { lgpFlexConditionsWellKnown 6062 } + +lgpCondId6063BatteryConverterCurrentLimit OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The battery converter has reached is maximum current limit. ." + ::= { lgpFlexConditionsWellKnown 6063 } + +lgpCondId6064LBSCableFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Load Bus Sync communications is abnormal. A problem with the LBS + cable may exist." + ::= { lgpFlexConditionsWellKnown 6064 } + +lgpCondId6065BatteryChargeEqualizationTimeout OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The battery equalizing is time out." + ::= { lgpFlexConditionsWellKnown 6065 } + +lgpCondId6066ParallelCableFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The UPS parallel system communications is abnormal. A problem with + the parallel cable may exist." + ::= { lgpFlexConditionsWellKnown 6066 } + +lgpCondId6067BatteryFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A short circuit exists in the battery system." + ::= { lgpFlexConditionsWellKnown 6067 } + +lgpCondId6068BatteryRoomAlarm OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The ambient temperature of the battery room is abnormal." + ::= { lgpFlexConditionsWellKnown 6068 } + +lgpCondId6080UPSCCommunicationFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The UPSC has failed to communicate in a designated time period." + ::= { lgpFlexConditionsWellKnown 6080 } + +lgpCondId6092Compressor1BThermalOverload OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Fixed compressor 1B is shut down due to thermal overload." + ::= { lgpFlexConditionsWellKnown 6092 } + +lgpCondId6093Compressor2BThermalOverload OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Fixed compressor 2B is shut down due to thermal overload." + ::= { lgpFlexConditionsWellKnown 6093 } + +lgpCondId6094Compressor1BHoursExceeded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Fixed compressor 1B run hours have exceeded the threshold." + ::= { lgpFlexConditionsWellKnown 6094 } + +lgpCondId6095Compressor2BHoursExceeded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Fixed compressor 2B run hours have exceeded the threshold." + ::= { lgpFlexConditionsWellKnown 6095 } + +lgpCondId6100CondenserRemoteShutdown OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Condenser is shut down by a remote signal." + ::= { lgpFlexConditionsWellKnown 6100 } + +lgpCondId6105ExternalCondenserTVSSIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The condenser Transient Voltage Surge Suppressor or Surge + Protection Device has failed, as indicated by an external input + signal." + ::= { lgpFlexConditionsWellKnown 6105 } + +lgpCondId6106ExternalCondenserVFDIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The condenser fan Variable Frequency Drive is offline, as + indicated by an external input signal." + ::= { lgpFlexConditionsWellKnown 6106 } + +lgpCondId6107ExternalCondenserIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Condenser is not operating within its operational parameters, as + indicated by an external input signal." + ::= { lgpFlexConditionsWellKnown 6107 } + +lgpCondId6119Slotsnotavailable OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The number of sensors exceeds the number of allocated slots and + cannot be displayed." + ::= { lgpFlexConditionsWellKnown 6119 } + +lgpCondId6180BatteryUnderVoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery voltage is too low." + ::= { lgpFlexConditionsWellKnown 6180 } + +lgpCondId6182ReplaceBattery OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The battery is due for replacement." + ::= { lgpFlexConditionsWellKnown 6182 } + +lgpCondId6186InputFrequencyDeviation OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The input frequency is outside of the normal range." + ::= { lgpFlexConditionsWellKnown 6186 } + +lgpCondId6187ShutdownPending OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Shutdown is pending." + ::= { lgpFlexConditionsWellKnown 6187 } + +lgpCondId6194SystemRebootCommandIssued OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reboot command issued to the system." + ::= { lgpFlexConditionsWellKnown 6194 } + +lgpCondId6203SensorAdded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Sensor Added." + ::= { lgpFlexConditionsWellKnown 6203 } + +lgpCondId6204SensorRemoved OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Sensor Removed." + ::= { lgpFlexConditionsWellKnown 6204 } + +lgpCondId6205WaterLeakDetected OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Water leak detected." + ::= { lgpFlexConditionsWellKnown 6205 } + +lgpCondId6210FirmwareUpdateInProgress OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Firmware update has started and is in progress." + ::= { lgpFlexConditionsWellKnown 6210 } + +lgpCondId6211FirmwareUpdateCompletedSuccessfully OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Firmware update has completed successfully." + ::= { lgpFlexConditionsWellKnown 6211 } + +lgpCondId6212FirmwareUpdateCompletedUnsuccessfully OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Firmware update has completed, but was not successful." + ::= { lgpFlexConditionsWellKnown 6212 } + +lgpCondId6216PrechargeCircuitFailed OBJECT-IDENTITY + STATUS current + DESCRIPTION + "DC Bus precharge/discharge didn't reach specified level within a + specified time." + ::= { lgpFlexConditionsWellKnown 6216 } + +lgpCondId6217MemoryCardRemoved OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The memory card on the control board has been removed." + ::= { lgpFlexConditionsWellKnown 6217 } + +lgpCondId6218AutoCalibrationActive OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system is automatically calibrating ADC channels." + ::= { lgpFlexConditionsWellKnown 6218 } + +lgpCondId6219AutoCalibrationFailed OBJECT-IDENTITY + STATUS current + DESCRIPTION + "ADC channel calibration has failed." + ::= { lgpFlexConditionsWellKnown 6219 } + +lgpCondId6220ModuleOutputBreakerOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The module output breaker is open." + ::= { lgpFlexConditionsWellKnown 6220 } + +lgpCondId6221NeutralVoltageFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Voltage observed on neutral line." + ::= { lgpFlexConditionsWellKnown 6221 } + +lgpCondId6222BranchLoadLoss OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Loss of load on branch detected. Branch circuit breaker might be + open." + ::= { lgpFlexConditionsWellKnown 6222 } + +lgpCondId6225RemoteSensorLowHumidity OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Remote sensor humidity has dropped below a lower threshold. The + event is deactivated when the humidity rises above the threshold." + ::= { lgpFlexConditionsWellKnown 6225 } + +lgpCondId6226RemoteSensorHighHumidity OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Remote sensor humidity has exceeded an upper threshold. The event + is deactivated when the humidity drops below the threshold." + ::= { lgpFlexConditionsWellKnown 6226 } + +lgpCondId6227RemoteSensorAverageLowHumidity OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The average humidity of multiple remote sensors on the cooling + unit has dropped below a lower threshold. The event is + deactivated when the humidity rises above the threshold." + ::= { lgpFlexConditionsWellKnown 6227 } + +lgpCondId6228RemoteSensorAverageHighHumidity OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The average humidity of multiple remote sensors on the cooling + unit has exceeded an upper threshold. The event is deactivated + when the humidity drops below the threshold." + ::= { lgpFlexConditionsWellKnown 6228 } + +lgpCondId6229RemoteSensorSystemAverageLowHumidity OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The average humidity of multiple remote sensors on interconnected + cooling units in a single system has dropped below a lower + threshold. The event is deactivated when the humidity rises + above the threshold." + ::= { lgpFlexConditionsWellKnown 6229 } + +lgpCondId6230RemoteSensorSystemAverageHighHumidity OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The average humidity of multiple remote sensors on interconnected + cooling units in a single system has exceeded an upper threshold. + The event is deactivated when the humidity drops below the + threshold." + ::= { lgpFlexConditionsWellKnown 6230 } + +lgpCondId6231LowCompressorSuperheat OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor suction superheat has dropped below a lower threshold." + ::= { lgpFlexConditionsWellKnown 6231 } + +lgpCondId6232SECUnspecifiedGeneralEvent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "One or more unspecified events active for the Superheat and + Envelope Controller. See local unit display for further details." + ::= { lgpFlexConditionsWellKnown 6232 } + +lgpCondId6233SECCommunicationLost OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Communication with the Superheat and Envelope Controller has been + lost. The event is deactivated when communication is re + -established." + ::= { lgpFlexConditionsWellKnown 6233 } + +lgpCondId6236PowerSourceAIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "No power is detected at power source input 'A'." + ::= { lgpFlexConditionsWellKnown 6236 } + +lgpCondId6237PowerSourceBIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "No power is detected at power source input 'B'." + ::= { lgpFlexConditionsWellKnown 6237 } + +lgpCondId6239FluidValveHoursExceeded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Operating hours for the fluid valve have exceeded the threshold." + ::= { lgpFlexConditionsWellKnown 6239 } + +lgpCondId6253BoosterFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Booster failure - boost is off." + ::= { lgpFlexConditionsWellKnown 6253 } + +lgpCondId6254ChargerFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Charger Failure - Charger is off." + ::= { lgpFlexConditionsWellKnown 6254 } + +lgpCondId6274UnitTopReturnAirSensorFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Return air sensor at the top of the unit is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 6274 } + +lgpCondId6275UnitMiddleReturnAirSensorFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Return air sensor in the middle of the unit is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 6275 } + +lgpCondId6276UnitBottomReturnAirSensorFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Return air sensor at the bottom of the unit is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 6276 } + +lgpCondId6277UnitTopSupplyAirSensorFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Supply air sensor at the top of the unit is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 6277 } + +lgpCondId6278UnitMiddleFirstSupplyAirSensorFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "First supply air sensor in the middle of the unit is disconnected + or the signal is out of range." + ::= { lgpFlexConditionsWellKnown 6278 } + +lgpCondId6279UnitBottomSupplyAirSensorFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Supply air sensor at the bottom of the unit is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 6279 } + +lgpCondId6284UnitMiddleSecondSupplyAirSensorFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Second supply air sensor in the middle of the unit is disconnected + or the signal is out of range." + ::= { lgpFlexConditionsWellKnown 6284 } + +lgpCondId6293ChilledWaterControlActive OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Chilled water inlet temperature control function is enabled due to + 'bad' water." + ::= { lgpFlexConditionsWellKnown 6293 } + +lgpCondId6294ChilledWaterFlowTransducerFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Chilled water flow transducer is disconnected or the signal is out + of range." + ::= { lgpFlexConditionsWellKnown 6294 } + +lgpCondId6295ChilledWaterInletTemperatureSensorFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Chilled water inlet temperature sensor is disconnected or the + signal is out of range. The sensor is mandatory for the chilled + water flow function." + ::= { lgpFlexConditionsWellKnown 6295 } + +lgpCondId6296ChilledWaterHighInletTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Chilled water inlet temperature has exceeded an upper threshold." + ::= { lgpFlexConditionsWellKnown 6296 } + +lgpCondId6297Modbus010VModuleCommunicationFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Modbus 0-10V module for managing the second Chilled Water circuit + valve is disconnected or the signal is out of range." + ::= { lgpFlexConditionsWellKnown 6297 } + +lgpCondId6299RackDoorsOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Rack doors opened due to supply air temperature exceeding the + [Rack Door Open High Supply Air Temperature Threshold]." + ::= { lgpFlexConditionsWellKnown 6299 } + +lgpCondId6303TeamStaticPressureSensorFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The team static pressure sensor is disconnected or the signal is + out of range." + ::= { lgpFlexConditionsWellKnown 6303 } + +lgpCondId6304HeatingLockout OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Heating is shut down and disabled." + ::= { lgpFlexConditionsWellKnown 6304 } + +lgpCondId6305FreeCoolingStoppedHighRoomTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Free cooling is temporarily disabled due to room temperature + exceeding a preset delta above the the set point." + ::= { lgpFlexConditionsWellKnown 6305 } + +lgpCondId6306ColdAisleTemperatureHumidityTeamSensorFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Cold aisle team sensor measuring air temperature and humidity is + disconnected or the signal is out of range." + ::= { lgpFlexConditionsWellKnown 6306 } + +lgpCondId6309ColdAisleAirSensorFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Cold aisle sensor measuring air temperature and humidity is + disconnected or the signal is out of range." + ::= { lgpFlexConditionsWellKnown 6309 } + +lgpCondId6310ChilledWaterInletTemperatureControlActive OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Chilled water inlet temperature control is active." + ::= { lgpFlexConditionsWellKnown 6310 } + +lgpCondId6313ChilledWaterInletTemperatureSensorFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Chilled water inlet temperature sensor is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 6313 } + +lgpCondId6314ChilledWaterOutletTemperatureSensorFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Chilled water outlet temperature sensor is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 6314 } + +lgpCondId6315ChilledWaterFlowMeterSensorFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Chilled water flow meter sensor is disconnected or the signal is + out of range." + ::= { lgpFlexConditionsWellKnown 6315 } + +lgpCondId6333Bypassoutofsync OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Bypass and Inverter inputs are not in sync." + ::= { lgpFlexConditionsWellKnown 6333 } + +lgpCondId6348SystemOutputoffasrequested OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The UPS has shutdown as requested, i.e., the output is off." + ::= { lgpFlexConditionsWellKnown 6348 } + +lgpCondId6349SystemOffasrequested OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The entire UPS has shutdown as commanded." + ::= { lgpFlexConditionsWellKnown 6349 } + +lgpCondId6350GeneralFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A general fault in the UPS has been detected." + ::= { lgpFlexConditionsWellKnown 6350 } + +lgpCondId6351UPSAwaitingPower OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The UPS output is off and the UPS is awaiting the return of input + power." + ::= { lgpFlexConditionsWellKnown 6351 } + +lgpCondId6352AutonomyCalibration OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Calibration test occurred." + ::= { lgpFlexConditionsWellKnown 6352 } + +lgpCondId6353GeneralWarning OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A warning in the UPS has been detected." + ::= { lgpFlexConditionsWellKnown 6353 } + +lgpCondId6354BatteryCharging OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The UPS battery is charging (battery charge percentage lower than + 98)." + ::= { lgpFlexConditionsWellKnown 6354 } + +lgpCondId6355BackfeedRelayFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Bypass SCR is wrongly on or commutated." + ::= { lgpFlexConditionsWellKnown 6355 } + +lgpCondId6356BatteryCircuitOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Battery Circuit Open." + ::= { lgpFlexConditionsWellKnown 6356 } + +lgpCondId6357SystemRestartPending OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A request for UPS restart has been received." + ::= { lgpFlexConditionsWellKnown 6357 } + +lgpCondId6358PipeTemperatureSensorFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Air temperature sensor located in the pipe is not sending a valid + value." + ::= { lgpFlexConditionsWellKnown 6358 } + +lgpCondId6362SFAReservedEvent26 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6362 } + +lgpCondId6363SFAReservedEvent27 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6363 } + +lgpCondId6364SFAReservedEvent28 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6364 } + +lgpCondId6365SFAReservedEvent29 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6365 } + +lgpCondId6366SFAReservedEvent30 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6366 } + +lgpCondId6367SFAReservedEvent31 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6367 } + +lgpCondId6368SFAReservedEvent32 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6368 } + +lgpCondId6369SFAReservedEvent33 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6369 } + +lgpCondId6370SFAReservedEvent34 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6370 } + +lgpCondId6371SFAReservedEvent35 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6371 } + +lgpCondId6372SFAReservedEvent36 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6372 } + +lgpCondId6373SFAReservedEvent37 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6373 } + +lgpCondId6374SFAReservedEvent38 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6374 } + +lgpCondId6375SFAReservedEvent39 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6375 } + +lgpCondId6376SFAReservedEvent40 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6376 } + +lgpCondId6377SFAReservedEvent41 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6377 } + +lgpCondId6378SFAReservedEvent42 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6378 } + +lgpCondId6379SFAReservedEvent43 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6379 } + +lgpCondId6380SFAReservedEvent44 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6380 } + +lgpCondId6381SFAReservedEvent45 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6381 } + +lgpCondId6382SFAReservedEvent46 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6382 } + +lgpCondId6383SFAReservedEvent47 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6383 } + +lgpCondId6384SFAReservedEvent48 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6384 } + +lgpCondId6385SFAReservedEvent49 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6385 } + +lgpCondId6386SFAReservedEvent50 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Reserved event for SFA use." + ::= { lgpFlexConditionsWellKnown 6386 } + +lgpCondId6438PowerModuleInputCurrentAbnormal OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Input current of the power module is abnormal." + ::= { lgpFlexConditionsWellKnown 6438 } + +lgpCondId6439PowerModuleBalancerofDCBusFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Balancer of DC Bus in the power module has failed." + ::= { lgpFlexConditionsWellKnown 6439 } + +lgpCondId6440PowerModuleFuseFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A summary event indicating one or more fuse failures in the power + module." + ::= { lgpFlexConditionsWellKnown 6440 } + +lgpCondId6441PowerModulePowerSupplyFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Power module power supply failure." + ::= { lgpFlexConditionsWellKnown 6441 } + +lgpCondId6450PDUPoweredOn OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The PDU was powered on." + ::= { lgpFlexConditionsWellKnown 6450 } + +lgpCondId6453InputWiringFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The neutral/ground conductors on the input wiring are not properly + bonded, or the line/neutral conductors have been swapped." + ::= { lgpFlexConditionsWellKnown 6453 } + +lgpCondId6454DCtoDCConverterFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A failure has occurred in the battery discharge circuit." + ::= { lgpFlexConditionsWellKnown 6454 } + +lgpCondId6455LeakSensorCableFault OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A fault is detected in the 'Leak Sensor' cable." + ::= { lgpFlexConditionsWellKnown 6455 } + +lgpCondId6518StandbyUnitActivatedDuetoChillerFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "External chiller unit has failed for this unit, so the standby + cooling unit has been activated." + ::= { lgpFlexConditionsWellKnown 6518 } + +lgpCondId6522PDUResidualOverCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a PDU residual over current condition." + ::= { lgpFlexConditionsWellKnown 6522 } + +lgpCondId6527PDUOverCurrentProtection OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The PDU over current protection is triggered." + ::= { lgpFlexConditionsWellKnown 6527 } + +lgpCondId6528PowerModuleLeverUnlocked OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The power module is inactive because the lever is in the unlocked + position." + ::= { lgpFlexConditionsWellKnown 6528 } + +lgpCondId6529HardwareMismatch OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The assigned system model settings do not match the actual + installed hardware. The module count is wrong, or a module of the + wrong type is installed." + ::= { lgpFlexConditionsWellKnown 6529 } + +lgpCondId6530SupplyNTCAirSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The supply NTC air sensor is disconnected or the signal is out of + range." + ::= { lgpFlexConditionsWellKnown 6530 } + +lgpCondId6531ExternalAirSensorCIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external air sensor C is disconnected or the signal is out of + range." + ::= { lgpFlexConditionsWellKnown 6531 } + +lgpCondId6532ExternalAirSensorDIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external air sensor D is disconnected or the signal is out of + range." + ::= { lgpFlexConditionsWellKnown 6532 } + +lgpCondId6533ExternalAirSensorEIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The external air sensor E is disconnected or the signal is out of + range." + ::= { lgpFlexConditionsWellKnown 6533 } + +lgpCondId6534PumpThermalOverload OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Pump is shut down due to thermal overload." + ::= { lgpFlexConditionsWellKnown 6534 } + +lgpCondId6535XDModuleCommunicationLost OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Communication with XD Module has been lost." + ::= { lgpFlexConditionsWellKnown 6535 } + +lgpCondId6536MMSCapacityExceeded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The critical load is larger than the redundant rating of a 1+N + redundant multi-module system." + ::= { lgpFlexConditionsWellKnown 6536 } + +lgpCondId6538TSAControlInputIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The analog input used to set the air temperature set point for + cooling control is disconnected or the signal is out of range." + ::= { lgpFlexConditionsWellKnown 6538 } + +lgpCondId6539ChilledWaterValveHoursExceeded OBJECT-IDENTITY + STATUS current + DESCRIPTION + "[Chilled Water Valve Hours] has exceeded [Chilled Water Valve + Operating Hours Threshold]." + ::= { lgpFlexConditionsWellKnown 6539 } + +lgpCondId6540FSAControlInputIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The analog input used to set the air temperature set point for fan + speed control is disconnected or the signal is out of range." + ::= { lgpFlexConditionsWellKnown 6540 } + +lgpCondId6541AutoTuneLicenseExpiring OBJECT-IDENTITY + STATUS current + DESCRIPTION + "License for the AutoTune feature has not been refreshed in 30 days + and will be expiring soon." + ::= { lgpFlexConditionsWellKnown 6541 } + +lgpCondId6542AutoTuneLicenseExpired OBJECT-IDENTITY + STATUS current + DESCRIPTION + "License for the AutoTune feature has expired." + ::= { lgpFlexConditionsWellKnown 6542 } + +lgpCondId6543UnitInStandbyDueToCoolingLoss OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Unit forced into standby because it is unable to provide any + cooling." + ::= { lgpFlexConditionsWellKnown 6543 } + +lgpCondId6544ControlUnitsRemoteShutdownMismatch OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The remote shutdown status of the primary control unit does not + match the remote shutdown status of the secondary control unit." + ::= { lgpFlexConditionsWellKnown 6544 } + +lgpCondId6545SecondaryControlUnitCommunicationLost OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The primary control unit has lost Ethernet communications with the + secondary control unit." + ::= { lgpFlexConditionsWellKnown 6545 } + +lgpCondId6546ControlUnitsUnitCodeMismatch OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Unit codes for the primary and secondary control units do not + match." + ::= { lgpFlexConditionsWellKnown 6546 } + +lgpCondId6547SSAControlInputIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The analog input used to set the static pressure set point for fan + speed control is disconnected or the signal is out of range." + ::= { lgpFlexConditionsWellKnown 6547 } + +lgpCondId6574SubfeedPhaseUndercurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Subfeed breaker phase current has dropped below the threshold." + ::= { lgpFlexConditionsWellKnown 6574 } + +lgpCondId6587TransferCountCleared OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A system event indicating the transfer count has been cleared." + ::= { lgpFlexConditionsWellKnown 6587 } + +lgpCondId6588EnergyCounterCleared OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A system event indicating the energy counter (e.g. KWH) has been + cleared." + ::= { lgpFlexConditionsWellKnown 6588 } + +lgpCondId6589HistoryLogsFull OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The history logs are full." + ::= { lgpFlexConditionsWellKnown 6589 } + +lgpCondId6590HistoryLogsCleared OBJECT-IDENTITY + STATUS current + DESCRIPTION + "History logs have been cleared." + ::= { lgpFlexConditionsWellKnown 6590 } + +lgpCondId6591EventLogCleared OBJECT-IDENTITY + STATUS current + DESCRIPTION + "All past alarms and faults have been cleared." + ::= { lgpFlexConditionsWellKnown 6591 } + +lgpCondId6592SystemDateChanged OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system date has been updated." + ::= { lgpFlexConditionsWellKnown 6592 } + +lgpCondId6593SystemTimeChanged OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system time has been updated." + ::= { lgpFlexConditionsWellKnown 6593 } + +lgpCondId6594AccessPasswordChanged OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The access password has been changed." + ::= { lgpFlexConditionsWellKnown 6594 } + +lgpCondId6595ConfigModified OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A setpoint has been updated." + ::= { lgpFlexConditionsWellKnown 6595 } + +lgpCondId6612SCRShort OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The SCR is in a short condition." + ::= { lgpFlexConditionsWellKnown 6612 } + +lgpCondId6613SCROpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The SCR is in an open condition." + ::= { lgpFlexConditionsWellKnown 6613 } + +lgpCondId6614ACPowerSupplyFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A failure of the AC Power Supply has been detected." + ::= { lgpFlexConditionsWellKnown 6614 } + +lgpCondId6615DCPowerSupplyFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A failure of the DC Power Supply has been detected." + ::= { lgpFlexConditionsWellKnown 6615 } + +lgpCondId6616VoltageSensorFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A voltage sensor failure has been detected." + ::= { lgpFlexConditionsWellKnown 6616 } + +lgpCondId6617SCRSensorFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The SCR sensor module failed." + ::= { lgpFlexConditionsWellKnown 6617 } + +lgpCondId6618CurrentSensorFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The current sensor module failed." + ::= { lgpFlexConditionsWellKnown 6618 } + +lgpCondId6619GateDriveFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The Gate Drive module failed." + ::= { lgpFlexConditionsWellKnown 6619 } + +lgpCondId6620SurgeFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The surge module failed for the input source." + ::= { lgpFlexConditionsWellKnown 6620 } + +lgpCondId6621FastUnderVoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Fast under voltage detected." + ::= { lgpFlexConditionsWellKnown 6621 } + +lgpCondId6622SlowUnderVoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Slow under voltage detected." + ::= { lgpFlexConditionsWellKnown 6622 } + +lgpCondId6623OverVoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Over voltage detected." + ::= { lgpFlexConditionsWellKnown 6623 } + +lgpCondId6624OverUnderFrequencyFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An over or under frequency condition has been detected." + ::= { lgpFlexConditionsWellKnown 6624 } + +lgpCondId6625GeneralSourceFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A non-specific failure has been detected in the source." + ::= { lgpFlexConditionsWellKnown 6625 } + +lgpCondId6626OverCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "An over current has been detected." + ::= { lgpFlexConditionsWellKnown 6626 } + +lgpCondId6627PeakCurrentOffLimit OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The peak current has exceeded the setpoint defined by I-PK Xfer + Lockout." + ::= { lgpFlexConditionsWellKnown 6627 } + +lgpCondId6628SyncFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A phase rotation/out of synchronization failure has been detected." + ::= { lgpFlexConditionsWellKnown 6628 } + +lgpCondId6629InputOverVoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Input over voltage." + ::= { lgpFlexConditionsWellKnown 6629 } + +lgpCondId6630InputUnderVoltage OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Input under voltage." + ::= { lgpFlexConditionsWellKnown 6630 } + +lgpCondId6631InputOverUnderFrequency OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Input over/under frequency." + ::= { lgpFlexConditionsWellKnown 6631 } + +lgpCondId6635VoltageSenseFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Output voltage sense failure." + ::= { lgpFlexConditionsWellKnown 6635 } + +lgpCondId6636LoadonAlternateSource OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The load is on the alternate source." + ::= { lgpFlexConditionsWellKnown 6636 } + +lgpCondId6637UnderVoltageFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Output under voltage failure." + ::= { lgpFlexConditionsWellKnown 6637 } + +lgpCondId6638OutputOverCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Output is over current." + ::= { lgpFlexConditionsWellKnown 6638 } + +lgpCondId6639GroundOverCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Ground is over current." + ::= { lgpFlexConditionsWellKnown 6639 } + +lgpCondId6640NeutralOverCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Neutral is over current." + ::= { lgpFlexConditionsWellKnown 6640 } + +lgpCondId6641LoadVoltageTHD OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Load voltage THD has exceeded the set limit." + ::= { lgpFlexConditionsWellKnown 6641 } + +lgpCondId6662ControlLogicFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A control logic module has failed." + ::= { lgpFlexConditionsWellKnown 6662 } + +lgpCondId6663PowerSupplyLogicFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "A power supply module has failed." + ::= { lgpFlexConditionsWellKnown 6663 } + +lgpCondId6664ExternalCommsFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "External communications failure." + ::= { lgpFlexConditionsWellKnown 6664 } + +lgpCondId6665HeatSinkOverTemp OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system heat sink temperature has exceeded design limits." + ::= { lgpFlexConditionsWellKnown 6665 } + +lgpCondId6666AutomaticTransferInhibited OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Automatic transfer is inhibited." + ::= { lgpFlexConditionsWellKnown 6666 } + +lgpCondId6667InputSourceTransferInhibited OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Input source transfer is inhibited." + ::= { lgpFlexConditionsWellKnown 6667 } + +lgpCondId6676CB1ShuntTrip OBJECT-IDENTITY + STATUS current + DESCRIPTION + "CB1 Shunt Trip event." + ::= { lgpFlexConditionsWellKnown 6676 } + +lgpCondId6677CB2ShuntTrip OBJECT-IDENTITY + STATUS current + DESCRIPTION + "CB2 Shunt Trip event." + ::= { lgpFlexConditionsWellKnown 6677 } + +lgpCondId6678CB6NeutralOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "CB6 neutral open event." + ::= { lgpFlexConditionsWellKnown 6678 } + +lgpCondId6679ContactorNeutralFail OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Contactor Neutral Fail event." + ::= { lgpFlexConditionsWellKnown 6679 } + +lgpCondId6680CB1BreakerOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "CB1 Breaker open event. Normal state is breaker closed. Latched + state is breaker open." + ::= { lgpFlexConditionsWellKnown 6680 } + +lgpCondId6681CB2BreakerOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "CB2 Breaker open event. Normal state is breaker closed. Latched + state is breaker open." + ::= { lgpFlexConditionsWellKnown 6681 } + +lgpCondId6682CB4BreakerClosed OBJECT-IDENTITY + STATUS current + DESCRIPTION + "CB4 breaker closed event. Normal state is breaker open. Latched + state is breaker closed." + ::= { lgpFlexConditionsWellKnown 6682 } + +lgpCondId6683CB5BreakerClosed OBJECT-IDENTITY + STATUS current + DESCRIPTION + "CB5 breaker closed event. Normal state is breaker open. Latched + state is breaker closed." + ::= { lgpFlexConditionsWellKnown 6683 } + +lgpCondId6684CB3BreakerOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "CB3 breaker open event. Normal state is breaker closed. Latched + state is breaker open." + ::= { lgpFlexConditionsWellKnown 6684 } + +lgpCondId6685CB3ABreakerOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "CB3A breaker open event. Normal state is breaker closed. Latched + state is breaker open." + ::= { lgpFlexConditionsWellKnown 6685 } + +lgpCondId6686CB6BreakerOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "CB6 breaker open event. Normal state is breaker closed. Latched + state is breaker open." + ::= { lgpFlexConditionsWellKnown 6686 } + +lgpCondId6687CB7BreakerOpen OBJECT-IDENTITY + STATUS current + DESCRIPTION + "CB7 breaker open event. Normal state is breaker closed. Latched + state is breaker open." + ::= { lgpFlexConditionsWellKnown 6687 } + +lgpCondId6691GroupIndependentOn OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The group standby/cascade state for this unit has been overridden. + The unit has been forced on." + ::= { lgpFlexConditionsWellKnown 6691 } + +lgpCondId6692GroupIndependentOff OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The group standby/cascade state for this unit has been overridden. + The unit has been forced off." + ::= { lgpFlexConditionsWellKnown 6692 } + +lgpCondId6693BranchResidualOverCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a branch residual over current condition." + ::= { lgpFlexConditionsWellKnown 6693 } + +lgpCondId6694ReceptacleResidualOverCurrent OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The system has detected a receptacle residual over current + condition." + ::= { lgpFlexConditionsWellKnown 6694 } + +lgpCondId6728BuckOn OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The input voltage is currently being bucked (lowered) by the + inverter." + ::= { lgpFlexConditionsWellKnown 6728 } + +lgpCondId6729BoostOn OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The input voltage is currently being boosted (raised) by the + inverter." + ::= { lgpFlexConditionsWellKnown 6729 } + +lgpCondId6739Compressor1HighPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor 1 High Pressure." + ::= { lgpFlexConditionsWellKnown 6739 } + +lgpCondId6740Compressor2HighPressure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor 2 High Pressure." + ::= { lgpFlexConditionsWellKnown 6740 } + +lgpCondId6741Compressor1ThermalOverload OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor 1 Thermal Overload." + ::= { lgpFlexConditionsWellKnown 6741 } + +lgpCondId6742Compressor2ThermalOverload OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor 2 Thermal Overload." + ::= { lgpFlexConditionsWellKnown 6742 } + +lgpCondId6758CompressorFreezeProtection OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compressor has entered the freeze protection phase." + ::= { lgpFlexConditionsWellKnown 6758 } + +lgpCondId6773FanTemperatureCompensationLimitReached OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Unit is configured for fan temperature compensation, and the fan + control set point cannot be reduced any further due to high + remote air temperature sensor readings." + ::= { lgpFlexConditionsWellKnown 6773 } + +lgpCondId6774ModbusECFanCommunicationLost OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Communication with Modbus EC fan has been lost." + ::= { lgpFlexConditionsWellKnown 6774 } + +lgpCondId6785AnalogTemperatureControlIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Analog input used for creating the control temperature (instead of + reading a sensor) is disconnected or the signal is out of range." + ::= { lgpFlexConditionsWellKnown 6785 } + +lgpCondId6786SubgroupFirmwareUpdateRequired OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Mismatch of subgroup firmware. Both the primary and secondary + control boards must be running the same firmware version." + ::= { lgpFlexConditionsWellKnown 6786 } + +lgpCondId6787SubgroupSecondaryControlUnitIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Subgroup secondary control unit is reporting an unspecified issue." + ::= { lgpFlexConditionsWellKnown 6787 } + +lgpCondId6788EEVCommunicationLost OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Communication with Electronic Expansion Valve unit has been lost." + ::= { lgpFlexConditionsWellKnown 6788 } + +lgpCondId6789EEVMotorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Electronic Expansion Valve stepper motor issue." + ::= { lgpFlexConditionsWellKnown 6789 } + +lgpCondId6790EEVFeedbackIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Electronic Expansion Valve feedback error." + ::= { lgpFlexConditionsWellKnown 6790 } + +lgpCondId6791EEVPressureSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Electronic Expansion Valve refrigerant pressure sensor is + disconnected or the signal is out of range." + ::= { lgpFlexConditionsWellKnown 6791 } + +lgpCondId6792EEVCoilTemperatureSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Electronic Expansion Valve coil temperature sensor is disconnected + or the signal is out of range." + ::= { lgpFlexConditionsWellKnown 6792 } + +lgpCondId6793EEVDischargeTemperatureSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Electronic Expansion Valve discharge temperature sensor is + disconnected or the signal is out of range." + ::= { lgpFlexConditionsWellKnown 6793 } + +lgpCondId6794EEVSumpTemperatureSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Electronic Expansion Valve sump temperature sensor is disconnected + or the signal is out of range." + ::= { lgpFlexConditionsWellKnown 6794 } + +lgpCondId6795EEVBatteryTestIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Electronic Expansion Valve battery state cannot be determined." + ::= { lgpFlexConditionsWellKnown 6795 } + +lgpCondId6796EEVBatteryPersistentIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Electronic Expansion Valve has continuously detected a 'bad' + battery condition for an extended period of time." + ::= { lgpFlexConditionsWellKnown 6796 } + +lgpCondId6798PumpCycleLockOut OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Pump is locked out due to multiple pump-to-compressor transitions + at cold ambient air temperature." + ::= { lgpFlexConditionsWellKnown 6798 } + +lgpCondId6799PumpBoardFirmwareUpdateRequired OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Mismatch of pump board firmware. All pump boards must be running + the same firmware version." + ::= { lgpFlexConditionsWellKnown 6799 } + +lgpCondId6800PumpControlBoardIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Pump is shut down due to a pump control board issue. Control + board must be rebooted." + ::= { lgpFlexConditionsWellKnown 6800 } + +lgpCondId6801PumpInvalidDataShutdown OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Pump is shut down due to invalid data." + ::= { lgpFlexConditionsWellKnown 6801 } + +lgpCondId6802PumpInputPressureSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Pump input refrigerant pressure sensor is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 6802 } + +lgpCondId6803PumpInputTemperatureSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Pump input refrigerant temperature sensor is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 6803 } + +lgpCondId6804PumpOutputPressureSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Pump output refrigerant pressure sensor is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 6804 } + +lgpCondId6805PumpOutputTemperatureSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Pump output refrigerant temperature sensor is disconnected or the + signal is out of range." + ::= { lgpFlexConditionsWellKnown 6805 } + +lgpCondId6806PumpCommunicationLost OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Communication with pump unit has been lost." + ::= { lgpFlexConditionsWellKnown 6806 } + +lgpCondId6807PumpRemoteShutdown OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Pump is shut down by a remote signal." + ::= { lgpFlexConditionsWellKnown 6807 } + +lgpCondId6808PumpUSBEthernetPortIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Pump control board USB or Ethernet interface has failed." + ::= { lgpFlexConditionsWellKnown 6808 } + +lgpCondId6809PumpStartupFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Multiple attempts to start the pump have failed." + ::= { lgpFlexConditionsWellKnown 6809 } + +lgpCondId6810PumpInverterFailure OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Pump inverter is reporting a failure." + ::= { lgpFlexConditionsWellKnown 6810 } + +lgpCondId6811PumpTVSSIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Pump Transient Voltage Surge Suppressor or Surge Protection Device + has failed." + ::= { lgpFlexConditionsWellKnown 6811 } + +lgpCondId6812PumpHighSuperheat OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Pump inlet refrigerant superheat temperature is too high, or the + pump has been running too long with the condenser fan off." + ::= { lgpFlexConditionsWellKnown 6812 } + +lgpCondId6813CondenserHighAmbientAirTempDelta OBJECT-IDENTITY + STATUS current + DESCRIPTION + "The difference between condenser measured ambient air temperatures + has been too large for an extended period of time." + ::= { lgpFlexConditionsWellKnown 6813 } + +lgpCondId6814CondenserLeeTempOptionMismatch OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Lee-Temp option configured at a condenser unit does not match Lee + -Temp option configured at the control unit." + ::= { lgpFlexConditionsWellKnown 6814 } + +lgpCondId6815CondenserBoardFirmwareUpdateRequired OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Mismatch of condenser board firmware. All condenser boards must + be running the same firmware version." + ::= { lgpFlexConditionsWellKnown 6815 } + +lgpCondId6816CondenserToPumpHighRefrigerantTempDelta OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Temperature delta between the condenser output refrigerant and + pump inlet refrigerant is too large." + ::= { lgpFlexConditionsWellKnown 6816 } + +lgpCondId6817CondenserRefrigerantTypeMismatch OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Refrigerant type configured at condenser unit does not match + refrigerant type configured at the control unit." + ::= { lgpFlexConditionsWellKnown 6817 } + +lgpCondId6818ExternalSupplyFluidHighTemperature OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Supply fluid temperature has exceeded a threshold, as indicated by + an external input signal." + ::= { lgpFlexConditionsWellKnown 6818 } + +lgpCondId6819ExternalSupplyFluidTempSensorIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Supply fluid temperature sensor is disconnected or the signal is + out of range, as indicated by an external input signal." + ::= { lgpFlexConditionsWellKnown 6819 } + +lgpCondId6822AuditLogUpdate OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Audit log has been updated." + ::= { lgpFlexConditionsWellKnown 6822 } + +lgpCondId6824ExternalSupplyFluidFlowIssue OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Supply fluid flow issue, as indicated by an external input signal." + ::= { lgpFlexConditionsWellKnown 6824 } + +END -- cgit v1.2.3