From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/protelevision/PT3080-MIB | 9498 +++++++++++++++++++++++++++++++++++++++++ 1 file changed, 9498 insertions(+) create mode 100644 MIBS/protelevision/PT3080-MIB (limited to 'MIBS/protelevision/PT3080-MIB') diff --git a/MIBS/protelevision/PT3080-MIB b/MIBS/protelevision/PT3080-MIB new file mode 100644 index 0000000..fbb5954 --- /dev/null +++ b/MIBS/protelevision/PT3080-MIB @@ -0,0 +1,9498 @@ +PT3080-MIB DEFINITIONS ::= BEGIN + +IMPORTS + pt FROM PT-MIB + MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, IpAddress FROM SNMPv2-SMI + MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP, AGENT-CAPABILITIES FROM SNMPv2-CONF + DateAndTime, DisplayString FROM SNMPv2-TC; + +pt3080 MODULE-IDENTITY + LAST-UPDATED "201506220940Z" + ORGANIZATION "ProTelevision Technologies A/S, Denmark" + CONTACT-INFO + "Contact: + + Web: http://www.protelevision.com + + Address: Valhoejs Alle 176, DK-2610 Roedovre, Denmark + Telephone: +45 44700000 + Fax: +45 44700001" + + DESCRIPTION + "This is the MIB file of PT3080 DVB-T/H Modulator. + + Copyright (c) 2008-2015 Protelevision Technologies A/S. + All rights reserved. + Reproduction of this document is authorized on the condition + that the foregoing copyright notice is included." + + REVISION + "201506220940Z" + + DESCRIPTION + "SWPROTELEVISION_P3_1_02_157 build 1441106393" + +::= { pt 3080 } + +pt3080System OBJECT IDENTIFIER ::= { pt3080 1 } +pt3080Mode OBJECT IDENTIFIER ::= { pt3080 2 } +pt3080Input OBJECT IDENTIFIER ::= { pt3080 3 } +pt3080Output OBJECT IDENTIFIER ::= { pt3080 4 } +pt3080Gps OBJECT IDENTIFIER ::= { pt3080 7 } +pt3080TSoIP OBJECT IDENTIFIER ::= { pt3080 10 } +pt3080Monitor OBJECT IDENTIFIER ::= { pt3080 12 } +pt3080Test OBJECT IDENTIFIER ::= { pt3080 13 } +pt3080Alarm OBJECT IDENTIFIER ::= { pt3080 14 } +pt3080Preset OBJECT IDENTIFIER ::= { pt3080 15 } +pt3080Eventlog OBJECT IDENTIFIER ::= { pt3080 16 } +pt3080Comms OBJECT IDENTIFIER ::= { pt3080 17 } +pt3080Demodulator OBJECT IDENTIFIER ::= { pt3080 24 } + +pt3080Precorrector OBJECT IDENTIFIER ::= { pt3080 25 } + +pt3080ASI OBJECT IDENTIFIER ::= { pt3080 30 } + +pt3080Reception OBJECT IDENTIFIER ::= { pt3080 26 } + +pt3080Backplane OBJECT IDENTIFIER ::= { pt3080 27 } + + +pt3080Notifs OBJECT IDENTIFIER ::= { pt3080 64 } + +pt3080Conformance OBJECT IDENTIFIER ::= { pt3080 100 } +pt3080Compliances OBJECT IDENTIFIER ::= { pt3080Conformance 1 } + +-- + +-- +-- pt3080 System sub-tree +-- + +pt3080SystemInstrumentFW1Rev OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The instrument FW1 revision" + ::= { pt3080System 7 } + +pt3080SystemInstrumentFW1RevBL OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The instrument FW1 BL revision" + ::= { pt3080System 8 } + +pt3080SystemInstrumentFW2Rev OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The instrument FW2 revision" + ::= { pt3080System 9 } + +pt3080SystemInstrumentFW2RevBL OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The instrument FW2 BL revision" + ::= { pt3080System 10 } + +pt3080SystemInstrumentFW3Rev OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The instrument FW3 revision" + ::= { pt3080System 11 } + +pt3080SystemInstrumentFW4Rev OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The instrument FW4 revision" + ::= { pt3080System 12 } + +pt3080SystemInstrumentPCBRev OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The instrument PCB revision" + ::= { pt3080System 13 } + +pt3080SystemInstrumentCalibrationRev OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The instrument Calibration revision" + ::= { pt3080System 14 } + +pt3080SystemInstrumentCalibrationDate OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The instrument Calibration date" + ::= { pt3080System 15 } + +pt3080SystemReboot OBJECT-TYPE + SYNTAX INTEGER { keeprunning(0), sameimage(1), otherimage(2), image0(3), image1(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Force a reboot of the device on the designated image now." + ::= { pt3080System 16 } + +pt3080SystemRebootDefaultConfig OBJECT-TYPE + SYNTAX INTEGER { keeprunning(0), reboot(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Restore all parameters to factory default and reboot the device on the same image." + ::= { pt3080System 19 } + +pt3080SystemDateTime OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The current date/time in local timezone of the device. + Format is YYYY MM DD HH MM SS." + ::= { pt3080System 22 } + +pt3080SystemImage0Version OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The image 0 version string." + ::= { pt3080System 24 } + +pt3080SystemImage0InstalledDate OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The date and time image 0 was installed." + ::= { pt3080System 25 } + +pt3080SystemImage1version OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The image 1 version string." + ::= { pt3080System 26 } + +pt3080SystemImage1InstalledDate OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The date and time image 0 was installed." + ::= { pt3080System 27 } + +pt3080SystemServiceLED OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control the Service LED on frontpanel." + ::= { pt3080System 28 } + +pt3080SystemLanguage OBJECT-TYPE + SYNTAX INTEGER { c(0), da-dk(1), ru-ru(2), es-es(3), pt-br(4), it-it(5), de-de(6), fr-fr(7) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls which language is used on web and facia. Change requires + reboot." + ::= { pt3080System 33 } + +pt3080SystemType OBJECT-TYPE + SYNTAX INTEGER { modulator(0), repeater(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The system type to start in on next reboot." + ::= { pt3080System 30 } + +pt3080SystemModulationStandard OBJECT-TYPE + SYNTAX INTEGER { dvbt(0), dvbt2(1), atsc(2), isdbt(3), iboc(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Modulation Standard to start in on next reboot." + ::= { pt3080System 32 } + +pt3080SystemCurrentImage OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The flash Image the device is currently booted from." + ::= { pt3080System 23 } + +pt3080SystemInstrumentKU OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The instrument serial number." + ::= { pt3080System 1 } + +pt3080SystemInstrumentType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The product type designation." + ::= { pt3080System 2 } + +pt3080SystemInstrumentOptions OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The options installed on this instrument." + ::= { pt3080System 6 } + +pt3080SystemDateTimeSync OBJECT-TYPE + SYNTAX INTEGER { manual(0), auto(1), gps(2), ntp(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The method used to synchronize system RTC. Mode auto means use + gps if available else ntp else manual." + ::= { pt3080System 20 } + +pt3080SystemDateTimeSyncActual OBJECT-TYPE + SYNTAX INTEGER { manual(0), auto(1), gps(2), ntp(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The actual method used to synchronize system RTC." + ::= { pt3080System 31 } + +pt3080SystemTimezone OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Time Zone used for displaying Data and Time." + ::= { pt3080System 21 } + +pt3080SystemInstrumentSWRev OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The instrument Software Revision currently running." + ::= { pt3080System 3 } + +pt3080SystemInstrumentBootLoaderRev OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The instrument Bootloader Software Revision." + ::= { pt3080System 4 } + +pt3080SystemInstrumentKernelRev OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The instrument O/S Kernel Version." + ::= { pt3080System 5 } + +pt3080SystemOperationOnTime OBJECT-TYPE + SYNTAX Integer32 + UNITS "1 secs" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of seconds this unit has been turned on since production." + ::= { pt3080System 34 } + +pt3080SystemOperationOnAirTime OBJECT-TYPE + SYNTAX Integer32 + UNITS "1 secs" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of seconds this unit has been unmuted since production." + ::= { pt3080System 35 } + +pt3080SystemOperationNumberOfBoots OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of times this unit has been booted since last factory + default restore." + ::= { pt3080System 36 } + +pt3080SystemBackplaneid OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "ID of the backplane the device is plugged into" + ::= { pt3080System 40 } + +pt3080SystemBackplaneIdRaw OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Raw ID of the backplane the device is plugged into" + ::= { pt3080System 41 } + +pt3080SystemBackplaneIdPcb OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "PCB version of the backplane the device is plugged into" + ::= { pt3080System 42 } + +pt3080SystemBackplaneIdCableOptions OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Cable options of the backplane the device is plugged into" + ::= { pt3080System 43 } + +pt3080SystemBackplaneIdMAnuf OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Manufacture ID of the backplane the device is plugged into" + ::= { pt3080System 44 } + +pt3080SystemBackplaneCalibrationDate OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Calibration date of the backplane the device is plugged into" + ::= { pt3080System 45 } + +pt3080SystemBackplaneCalibrationSw OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Calibration SW version of the backplane the device is plugged + into" + ::= { pt3080System 46 } + +pt3080SystemBackplaneIdPartlist OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Partlist version of the backplane the device is plugged into" + ::= { pt3080System 47 } + + +-- Scheduled Action table -- + +pt3080SystemScheduledActionTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pt3080SystemScheduledActionEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the scheduled actions" + ::= { pt3080System 50 } + +pt3080SystemScheduledActionEntry OBJECT-TYPE + SYNTAX Pt3080SystemScheduledActionEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the scheduled action" + INDEX { pt3080SystemScheduledActionID } + ::= { pt3080SystemScheduledActionTable 1 } + +Pt3080SystemScheduledActionEntry ::= SEQUENCE { + pt3080SystemScheduledActionID Integer32, + pt3080SystemScheduledActionRecurrence INTEGER, + pt3080SystemScheduledActionHour Integer32, + pt3080SystemScheduledActionMinute Integer32, + pt3080SystemScheduledActionWeekday INTEGER, + pt3080SystemScheduledActionMonthDay Integer32, + pt3080SystemScheduledActionDate DisplayString, + pt3080SystemScheduledActionRandomDelay Integer32, + pt3080SystemScheduledActionAction INTEGER, + pt3080SystemScheduledActionRepeaterMode INTEGER, + pt3080SystemScheduledActionPresetNo INTEGER, + pt3080SystemScheduledActionRebootImage INTEGER, + pt3080SystemScheduledActionRebootSystemType INTEGER, + pt3080SystemScheduledActionMute INTEGER, + pt3080SystemScheduledActionSWUpgradeProtocol INTEGER, + pt3080SystemScheduledActionSWUpgradeUsername DisplayString, + pt3080SystemScheduledActionSWUpgradePassword DisplayString, + pt3080SystemScheduledActionSWUpgradeImageServer DisplayString, + pt3080SystemScheduledActionSWUpgradeImagePath DisplayString +} + +pt3080SystemScheduledActionID OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 10 ) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique ID for this scheduled action entry" + ::= { pt3080SystemScheduledActionEntry 1 } + +pt3080SystemScheduledActionRecurrence OBJECT-TYPE + SYNTAX INTEGER { never(0), immediate(1), once(2), hourly(3), daily(4), weekly(5), monthly(6) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The interval at which this scheduled action entry will be executed" + ::= { pt3080SystemScheduledActionEntry 2 } + +pt3080SystemScheduledActionHour OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 23 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The recurrence hour used when pt3080SystemScheduledActionRecurrence is once, hourly, dayly, weekly and monthly." + ::= { pt3080SystemScheduledActionEntry 3 } + +pt3080SystemScheduledActionMinute OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 59 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The recurrence minute used when pt3080SystemScheduledActionRecurrence is once, hourly, dayly, weekly and monthly." + ::= { pt3080SystemScheduledActionEntry 4 } + +pt3080SystemScheduledActionWeekday OBJECT-TYPE + SYNTAX INTEGER { monday(0), tuesday(1), wednesday(2), thursday(3), friday(4), saturday(5), sunday(6) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The recurrence weekday used when pt3080SystemScheduledActionRecurrence is weekly." + ::= { pt3080SystemScheduledActionEntry 5 } + +pt3080SystemScheduledActionMonthDay OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 31 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The recurrence day of the monthe used when pt3080SystemScheduledActionRecurrence is monthly." + ::= { pt3080SystemScheduledActionEntry 6 } + +pt3080SystemScheduledActionDate OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The recurrence date used when pt3080SystemScheduledActionRecurrence is once. + The format is dd/mm/yyyy." + ::= { pt3080SystemScheduledActionEntry 7 } + +pt3080SystemScheduledActionRandomDelay OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 600 ) + UNITS "secs" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "An extra random delay added before the action for this entry is executed. + A setting of x means that a random delay between 0 and x seconds are added." + ::= { pt3080SystemScheduledActionEntry 8 } + +pt3080SystemScheduledActionAction OBJECT-TYPE + SYNTAX INTEGER { none(0), repeatermode(1), preset(2), swupgrade(3), reboot(4), mute(5) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The action for this entry is executed" + ::= { pt3080SystemScheduledActionEntry 9 } + +pt3080SystemScheduledActionRepeaterMode OBJECT-TYPE + SYNTAX INTEGER { auto(0), + digital-iso-repeater(1), + digital-transposer(2), + analog-iso-repeater(3), + analog-transposer(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The new repeater mode to change to when pt3080SystemScheduledActionAction + of type repeatermode is executed" + ::= { pt3080SystemScheduledActionEntry 10 } + +pt3080SystemScheduledActionPresetNo OBJECT-TYPE + SYNTAX INTEGER { auto(0), + digital-iso-repeater(1), + digital-transposer(2), + analog-iso-repeater(3), + analog-transposer(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The preset to load when pt3080SystemScheduledActionAction + of type preset is executed" + ::= { pt3080SystemScheduledActionEntry 11 } + +pt3080SystemScheduledActionRebootImage OBJECT-TYPE + SYNTAX INTEGER { sameimage(0), otherimage(1), image0(2), image1(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The image to reboot to when pt3080SystemScheduledActionAction + of type reboot is executed" + ::= { pt3080SystemScheduledActionEntry 12 } + +pt3080SystemScheduledActionRebootSystemType OBJECT-TYPE + SYNTAX INTEGER { modulator(0), repeater(1), same(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The system type to reboot to when pt3080SystemScheduledActionAction + of type reboot is executed" + ::= { pt3080SystemScheduledActionEntry 13 } + +pt3080SystemScheduledActionMute OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The mute mode to change into when pt3080SystemScheduledActionAction + of type mute is executed" + ::= { pt3080SystemScheduledActionEntry 14 } + +pt3080SystemScheduledActionSWUpgradeProtocol OBJECT-TYPE + SYNTAX INTEGER { http(0), ftp(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The protocol to use into when pt3080SystemScheduledActionAction + of type swupgrade(3) is executed" + ::= { pt3080SystemScheduledActionEntry 15 } + +pt3080SystemScheduledActionSWUpgradeUsername OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The username to use into when pt3080SystemScheduledActionAction + of type swupgrade(3) is executed" + ::= { pt3080SystemScheduledActionEntry 16 } + +pt3080SystemScheduledActionSWUpgradePassword OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The password to use into when pt3080SystemScheduledActionAction + of type swupgrade(3) is executed" + ::= { pt3080SystemScheduledActionEntry 17 } + +pt3080SystemScheduledActionSWUpgradeImageServer OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The server name to use into when pt3080SystemScheduledActionAction + of type swupgrade(3) is executed" + ::= { pt3080SystemScheduledActionEntry 18 } + +pt3080SystemScheduledActionSWUpgradeImagePath OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The image path name to use into when pt3080SystemScheduledActionAction + of type swupgrade(3) is executed" + ::= { pt3080SystemScheduledActionEntry 19 } + +-- +-- pt3080 Mode sub-tree +-- +pt3080ModeListenBroadcast OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control wheter to react on broadcast tx id." + ::= { pt3080Mode 40 } + + +pt3080ModeNetwork OBJECT-TYPE + SYNTAX INTEGER { network-mode-mfn(0), network-mode-sfn(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Network mode multi-frequency-network or single-frequency-network" + ::= { pt3080Mode 1 } + +pt3080ModeHierarchy OBJECT-TYPE + SYNTAX INTEGER { network-hierarchy-none(0), network-hierarchy-h1(1), network-hierarchy-h2(2), network-hierarchy-h4(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Hierarchy mode. Cannot be set if pt3080ModeMipControl is on(1)." + ::= { pt3080Mode 2 } + +pt3080Modeifft OBJECT-TYPE + SYNTAX INTEGER { ifft-mode-2k(0), ifft-mode-4k(1), ifft-mode-8k(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "IFFT 2k, 4k or 8k mode. Cannot be set if pt3080ModeMipControl is on(1)." + ::= { pt3080Mode 3 } + +pt3080ModeCodeRateHighPrio OBJECT-TYPE + SYNTAX INTEGER { + code-rate-1-2(0), + code-rate-2-3(1), + code-rate-3-4(2), + code-rate-5-6(3), + code-rate-7-8(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "High Priority Code Rate. Cannot be set if pt3080ModeMipControl is on(1)." + ::= { pt3080Mode 4 } + +pt3080ModeCodeRateLowPrio OBJECT-TYPE + SYNTAX INTEGER { + code-rate-1-2(0), + code-rate-2-3(1), + code-rate-3-4(2), + code-rate-5-6(3), + code-rate-7-8(4)} + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Low Priority Code Rate. Cannot be set if pt3080ModeMipControl is on(1)." + ::= { pt3080Mode 5 } + +pt3080ModeConstellation OBJECT-TYPE + SYNTAX INTEGER { + qpsk(0), + qam16(1), + qam64(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "If QPSK is selected and Hierarchical is <> NONE, + then Hierarchical will be forced to NONE. Cannot be set if pt3080ModeMipControl is on(1)." + ::= { pt3080Mode 6 } + +pt3080ModeGuardInterval OBJECT-TYPE + SYNTAX INTEGER { + guard-1-32(0), + guard-1-16(1), + guard-1-8(2), + guard-1-4(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Guard Interval. Cannot be set if pt3080ModeMipControl is on(1)." + ::= { pt3080Mode 7 } + +pt3080ModeCellID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Sets the Cell ID value. Cannot be set if pt3080ModeMipControl is on(1)." + ::= { pt3080Mode 8 } + +pt3080ModeEnableCellID OBJECT-TYPE + SYNTAX INTEGER {off(0), on(1)} + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables Cell ID in the TPS information. Cannot be set if pt3080ModeMipControl is on(1). + Cannot be set to off(0) if pt3080ModeEnableDVBH is on(1)" + ::= { pt3080Mode 9 } + +pt3080ModeDeepInterleaver OBJECT-TYPE + SYNTAX INTEGER {off(0), on(1)} + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables Deep Interleaver. Cannot be set if pt3080ModeMipControl is on(1)." + ::= { pt3080Mode 10 } + +pt3080ModeEnableDVBH OBJECT-TYPE + SYNTAX INTEGER {off(0), on(1)} + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables DVB-H mode" + ::= { pt3080Mode 11 } + +pt3080ModeMpeFecLowPrio OBJECT-TYPE + SYNTAX INTEGER {off(0), on(1)} + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables MPE Fec Low Priority. Cannot be set if pt3080ModeMipControl is on(1)." + ::= { pt3080Mode 12 } + +pt3080ModeMpeFecHighPrio OBJECT-TYPE + SYNTAX INTEGER {off(0), on(1)} + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables MPE Fec High Priority. Cannot be set if pt3080ModeMipControl is on(1)." + ::= { pt3080Mode 13 } + +pt3080ModeTimeSlicingLowPrio OBJECT-TYPE + SYNTAX INTEGER {off(0), on(1)} + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables timeslicing High Priority. Cannot be set if pt3080ModeMipControl is on(1)." + ::= { pt3080Mode 14 } + +pt3080ModeTimeSlicingHighPrio OBJECT-TYPE + SYNTAX INTEGER {off(0), on(1)} + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables timeslicing High Priority. Cannot be set if pt3080ModeMipControl is on(1)." + ::= { pt3080Mode 15 } + + +pt3080ModeSfnDelayOffset OBJECT-TYPE + SYNTAX Integer32 ( -9999999 .. 9999999 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "SFN delay offset" + ::= { pt3080Mode 16 } + + +pt3080ModeTxIdent OBJECT-TYPE + SYNTAX Integer32 ( 0..65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The transport stream control identifier" + ::= { pt3080Mode 17 } + +pt3080ModeMipControl OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables transport stream control of modulator" + ::= { pt3080Mode 18 } + +pt3080ModeMfnKeepNullPackets OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables MFN mode keep null packets option" + ::= { pt3080Mode 19 } + +pt3080ModeNetworkDelayHP OBJECT-TYPE + SYNTAX Integer32 + UNITS "100ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current network delay of HP TS" + ::= { pt3080Mode 20 } + +pt3080ModeNetworkDelayMinHP OBJECT-TYPE + SYNTAX Integer32 + UNITS "100ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum network delay of HP TS seen since last reset" + ::= { pt3080Mode 21 } + +pt3080ModeNetworkDelayMaxHP OBJECT-TYPE + SYNTAX Integer32 + UNITS "100ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum network delay of HP TS seen since last reset" + ::= { pt3080Mode 22 } + +pt3080ModeMaxNetworkDelayHP OBJECT-TYPE + SYNTAX Integer32 + UNITS "100ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum allowed network delay, as received from MIP" + ::= { pt3080Mode 23 } + +pt3080ModeNetworkDelayMarginHP OBJECT-TYPE + SYNTAX Integer32 + UNITS "100ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Difference between Actual Network Delay and Max. Allowed Network Delay" + ::= { pt3080Mode 24 } + +pt3080ModeNetworkDelayLP OBJECT-TYPE + SYNTAX Integer32 + UNITS "100ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current network delay of LP TS" + ::= { pt3080Mode 25 } + +pt3080ModeNetworkDelayMinLP OBJECT-TYPE + SYNTAX Integer32 + UNITS "100ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Minimum network delay of LP TS seen since last reset" + ::= { pt3080Mode 26 } + +pt3080ModeNetworkDelayMaxLP OBJECT-TYPE + SYNTAX Integer32 + UNITS "100ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum network delay of LP TS seen since last reset" + ::= { pt3080Mode 27 } + +pt3080ModeMaxNetworkDelayLP OBJECT-TYPE + SYNTAX Integer32 + UNITS "100ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum allowed network delay, as received from MIP" + ::= { pt3080Mode 28 } + +pt3080ModeNetworkDelayMarginLP OBJECT-TYPE + SYNTAX Integer32 + UNITS "100ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Difference between Actual Network Delay and Max. Allowed Network Delay" + ::= { pt3080Mode 29 } + +pt3080ModeNetworkDelayReset OBJECT-TYPE + SYNTAX INTEGER { noop(0), reset(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reset network delay. Always reads back as noop(0)" + ::= { pt3080Mode 30 } + +pt3080ModeDefaultMIPOutputPower OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 1000 ) + UNITS "0.1 dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Default MIP value for Output Power Level. Cannot be set if pt3080ModeMipControlOutputPower is on(1)" + ::= { pt3080Mode 31 } + +pt3080ModeDefaultMIPOutputTimeOffset OBJECT-TYPE + SYNTAX Integer32 ( -9999999 .. 9999999 ) + UNITS "x100ns" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Default MIP value for Output SFN Time Offset. Cannot be set if pt3080ModeMipControlOutputTimeOffset is on(1)" + ::= { pt3080Mode 32 } + +pt3080ModeDefaultMIPOutputCellID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Default MIP value for Output Cell ID. Cannot be set if pt3080ModeMipControlOutputCellId is on(1)" + ::= { pt3080Mode 33 } + +pt3080ModeDefaultMIPOutputFreqOffset OBJECT-TYPE + SYNTAX Integer32 ( -8388608 .. 8388607 ) + UNITS "Hz" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Default MIP value for Output frequency Offset. Cannot be set if pt3080ModeMipControlOutputFreqOffset is on(1)" + ::= { pt3080Mode 34 } + +pt3080ModeMIPMaxSFNDelay OBJECT-TYPE + SYNTAX Integer32 + UNITS "x100ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The MIP value for SFN maximum delay" + ::= { pt3080Mode 35 } + +pt3080ModeMipControlOutputPower OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables transport stream control of ModeDefaultMIPOutputPower" + ::= { pt3080Mode 36 } + +pt3080ModeMipControlOutputTimeOffset OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables transport stream control of ModeDefaultMIPOutputTimeOffset" + ::= { pt3080Mode 37 } + +pt3080ModeMipControlOutputCellId OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables transport stream control of ModeDefaultMIPOutputCellId" + ::= { pt3080Mode 38 } + +pt3080ModeMipControlOutputFreqOffset OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables transport stream control of ModeDefaultMIPOutputFreqOffset" + ::= { pt3080Mode 39 } + + + + + +pt3080ReceptionGainControl OBJECT-TYPE + SYNTAX INTEGER { auto(0), freeze(1), manual(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls the gain function mode." + ::= { pt3080Reception 9 } + +pt3080ReceptionGainManualValue OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 700 ) + UNITS "0.1 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines manual gain value." + ::= { pt3080Reception 10 } + +pt3080ReceptionGainLimitEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls the Reception RF Gain limit function." + ::= { pt3080Reception 11 } + +pt3080ReceptionGainLimit OBJECT-TYPE + SYNTAX Integer32 ( 200 .. 700 ) + UNITS "0.1 db" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines gain limit value." + ::= { pt3080Reception 12 } + +pt3080ReceptionGainCurrent OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.01 db" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current total gain." + ::= { pt3080Reception 13 } + +pt3080ReceptionAGCMode OBJECT-TYPE + SYNTAX INTEGER { slow(0), fast(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls the AGC function mode." + ::= { pt3080Reception 30 } + +pt3080ReceptionAGCHysteresis OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 200 ) + UNITS "0.01 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the AGC function Hysteresis." + ::= { pt3080Reception 31 } + +pt3080ReceptionBandwidth OBJECT-TYPE + SYNTAX INTEGER { r5(0), r6(1), r7(2), r8(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls reception bandwidth" + ::= { pt3080Reception 23 } + +pt3080ReceptionRFFrequency OBJECT-TYPE + SYNTAX Integer32 ( 30000000 .. 954000000 ) + UNITS "1 hz" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the reception frequency for the tuner." + ::= { pt3080Reception 1 } + +pt3080ReceptionRFFrequencyOffset OBJECT-TYPE + SYNTAX Integer32 ( -500000 .. 500000 ) + UNITS "1 hz" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the offset to be added to the reception frequency for + the tuner." + ::= { pt3080Reception 2 } + +pt3080ReceptionRFPolarity OBJECT-TYPE + SYNTAX INTEGER { norm(0), inv(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls RF reception Polarity" + ::= { pt3080Reception 24 } + +pt3080ReceptionRFSquelchEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls the squelch function." + ::= { pt3080Reception 6 } + +pt3080ReceptionRFSquelchThreshold OBJECT-TYPE + SYNTAX Integer32 ( -800 .. -70 ) + UNITS "0.1 dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the Squelch function threshold." + ::= { pt3080Reception 7 } + +pt3080ReceptionRFSquelchHysteresis OBJECT-TYPE + SYNTAX Integer32 ( 10 .. 500 ) + UNITS "0.01 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the Squelch function Hysteresis." + ::= { pt3080Reception 8 } + +pt3080ReceptionRFTrackingFilterEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls the Reception RF Tracking Filter." + ::= { pt3080Reception 35 } + +pt3080ReceptionRFifLevel OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 dB" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current if level from the tuner." + ::= { pt3080Reception 36 } + +pt3080ReceptionRFNominalInputLevel OBJECT-TYPE + SYNTAX Integer32 ( -400 .. 100 ) + UNITS "0.1 dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The nominal input level on the tuner. The dynamic range of the + tuner is from 20dB below nominal level to nominal level" + ::= { pt3080Reception 37 } + +pt3080ReceptionRFInputLevel OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current RF input level on the tuner." + ::= { pt3080Reception 21 } + +pt3080ReceptionRFInputLevelThreshold OBJECT-TYPE + SYNTAX Integer32 ( -8000 .. -700 ) + UNITS "0.01 dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the Input level threshold." + ::= { pt3080Reception 26 } + +pt3080ReceptionRFInputLevelHysteresis OBJECT-TYPE + SYNTAX Integer32 ( 10 .. 500 ) + UNITS "0.01 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the Input Level Hysteresis." + ::= { pt3080Reception 25 } + +pt3080ReceptionIFFrequency OBJECT-TYPE + SYNTAX INTEGER { if36mhz(0), if36p15mhz(1), if40mhz(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the reception frequency for the tuner." + ::= { pt3080Reception 4 } + +pt3080ReceptionIFPolarity OBJECT-TYPE + SYNTAX INTEGER { norm(0), inv(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls IF reception Polarity" + ::= { pt3080Reception 5 } + +pt3080ReceptionIFInputLevel OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.01 dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows the current IF input level" + ::= { pt3080Reception 22 } + +pt3080ReceptionIFInputPolicy OBJECT-TYPE + SYNTAX INTEGER { rf(0), if(1), rfav(2), ifav(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls RF/IF reception Policy" + ::= { pt3080Reception 3 } + +pt3080ReceptionIFInput OBJECT-TYPE + SYNTAX INTEGER { if(0), rf(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows the current RF/IF input selected" + ::= { pt3080Reception 20 } + +pt3080ReceptionIFRFtoIFHoldoverDelay OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 300 ) + UNITS "1 secs" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The holdover delay for switching reception from RF to IF input." + ::= { pt3080Reception 18 } + +pt3080ReceptionIFIFtoRFHoldoverDelay OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 300 ) + UNITS "1 secs" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The holdover delay for switching reception from IF to RF input." + ::= { pt3080Reception 19 } + +pt3080ReceptionTunerHWVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The tuner HW version." + ::= { pt3080Reception 40 } + +pt3080ReceptionTunerHWType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The tuner HW type." + ::= { pt3080Reception 41 } + +pt3080ReceptionTunerHWID OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The tuner HW ID." + ::= { pt3080Reception 42 } + +pt3080ReceptionTunerHWSerialNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The tuner HW Serial Number." + ::= { pt3080Reception 43 } + +pt3080ReceptionTunerHWCalibrationDate OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The tuner HW Calibration Date." + ::= { pt3080Reception 44 } + +pt3080ReceptionTunerHWCalibrationDataVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The tuner HW Calibration Data Version." + ::= { pt3080Reception 45 } + +pt3080ReceptionTunerHWCalibrationSWVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The tuner HW Calibration SW Version." + ::= { pt3080Reception 46 } + + +-- +-- pt3080 ASI sub-tree +-- + +pt3080ASIInput1SyncTimeout OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 250 ) + UNITS "1 ms" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies the maximum time accepted between received TS packages." + ::= { pt3080ASI 1 } + +pt3080ASIInput2SyncTimeout OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 250 ) + UNITS "1 ms" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies the maximum time accepted between received TS packages." + ::= { pt3080ASI 51 } + +pt3080ASIInput1DataErrorLimit OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 20000 ) + UNITS "0.1 bits/s" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies the alarm limit for date error rate." + ::= { pt3080ASI 2 } + +pt3080ASIInput2DataErrorLimit OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 20000 ) + UNITS "0.1 bits/s" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies the alarm limit for date error rate." + ::= { pt3080ASI 52 } + +pt3080ASIInput1SyncStatus OBJECT-TYPE + SYNTAX INTEGER { locked(0), unlocked(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current state of the sync detector" + ::= { pt3080ASI 3 } + +pt3080ASIInput2SyncStatus OBJECT-TYPE + SYNTAX INTEGER { locked(0), unlocked(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current state of the sync detector" + ::= { pt3080ASI 53 } + +pt3080ASIInput1SyncSignal OBJECT-TYPE + SYNTAX INTEGER { undefined(0), norm(1), inv(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current state of the sync detector signal type" + ::= { pt3080ASI 4 } + +pt3080ASIInput2SyncSignal OBJECT-TYPE + SYNTAX INTEGER { undefined(0), norm(1), inv(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current state of the sync detector signal type" + ::= { pt3080ASI 54 } + +pt3080ASIInput1SyncTSSize OBJECT-TYPE + SYNTAX INTEGER { undefined(0), ts188(1), ts204(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current TS packet size determined by the sync detector" + ::= { pt3080ASI 5 } + +pt3080ASIInput2SyncTSSize OBJECT-TYPE + SYNTAX INTEGER { undefined(0), ts188(1), ts204(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current TS packet size determined by the sync detector" + ::= { pt3080ASI 55 } + +pt3080ASIInput1LineErrors OBJECT-TYPE + SYNTAX Integer32 + UNITS "1 bits" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Counts the number of line errors including IDLE stuffing." + ::= { pt3080ASI 6 } + +pt3080ASIInput2LineErrors OBJECT-TYPE + SYNTAX Integer32 + UNITS "1 bits" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Counts the number of line errors including IDLE stuffing." + ::= { pt3080ASI 56 } + +pt3080ASIInput1LineRate OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Mbps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current line rate" + ::= { pt3080ASI 7 } + +pt3080ASIInput2LineRate OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Mbps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current line rate" + ::= { pt3080ASI 57 } + +pt3080ASIInput1LineErrorRate OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 bits/s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current line error rate" + ::= { pt3080ASI 8 } + +pt3080ASIInput2LineErrorRate OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 bits/s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current line error rate" + ::= { pt3080ASI 58 } + +pt3080ASIInput1DataErrors OBJECT-TYPE + SYNTAX Integer32 + UNITS "1 bits" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Counts the number of data errors excluding IDLE stuffing." + ::= { pt3080ASI 9 } + +pt3080ASIInput2DataErrors OBJECT-TYPE + SYNTAX Integer32 + UNITS "1 bits" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Counts the number of data errors excluding IDLE stuffing." + ::= { pt3080ASI 59 } + +pt3080ASIInput1DataRate OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Mbps/s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current data rate" + ::= { pt3080ASI 10 } + +pt3080ASIInput2DataRate OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Mbps/s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current data rate" + ::= { pt3080ASI 60 } + +pt3080ASIInput1DataErrorRate OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 bits/s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current data error rate" + ::= { pt3080ASI 11 } + +pt3080ASIInput2DataErrorRate OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 bits/s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current data error rate" + ::= { pt3080ASI 61 } + +pt3080ASIInput1ClearErrorCounters OBJECT-TYPE + SYNTAX INTEGER { noop(0), activate(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Clear all error counters and reset all rates" + ::= { pt3080ASI 12 } + +pt3080ASIInput2ClearErrorCounters OBJECT-TYPE + SYNTAX INTEGER { noop(0), activate(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Clear all error counters and reset all rates" + ::= { pt3080ASI 62 } + + +-- +-- pt3080 Input sub-tree +-- + +pt3080InputRefDevType OBJECT-TYPE + SYNTAX INTEGER { tcxo-int(0), ocxo-pt3710-10(1), ocxo-pt3710-20(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Type of TCXO/OCXO" + ::= { pt3080Input 90 } + +pt3080InputRefCalDate OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Calibration Date" + ::= { pt3080Input 91 } + +pt3080InputRefCalVer OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Calibration SW Version" + ::= { pt3080Input 92 } + +pt3080InputRefDirection OBJECT-TYPE + SYNTAX INTEGER { input(0), output(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "monitors the Reference signal direction. state: - inputOutput[inputOutput_INPUT] + - inputOutput[inputOutput_OUTPUT]" + ::= { pt3080Input 1 } + +pt3080InputRefSource OBJECT-TYPE + SYNTAX INTEGER { auto(0), ext(1), int(2), gps(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the input reference synchronisation source. If the value + AUTO is chosen, the source is chosen automatically between + available sources. The order of choice is GPS->EXT10MHz->INT. + If the value EXT is chosen, the external clock is chosen as + source If the value INT is chosen, the internal clock is chosen + as source. If the value GPS is chosen, the GNSS 1PPS clock + is chosen as source." + ::= { pt3080Input 2 } + +pt3080InputRefStatus OBJECT-TYPE + SYNTAX INTEGER { external(0), external-10mhz(1), external-1pps(2), internal(3), gnss(4), asi1(5), asi2(6), ndel(7) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "returns the current input reference synchronisation source." + ::= { pt3080Input 11 } + +pt3080InputRef10MhzImpedance OBJECT-TYPE + SYNTAX INTEGER { o-50(0), himp(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the external 10 MHz input reference synchronisation + source impedance. The value is either 50O or high impedance." + ::= { pt3080Input 3 } + +pt3080InputRef10MhzHoldoverDelay OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 172800 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the external 10 MHz input reference synchronisation + source impedance. The value is either 50O or high impedance." + ::= { pt3080Input 7 } + +pt3080InputRef10MhzHoldoverForever OBJECT-TYPE + SYNTAX INTEGER { no(0), yes(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The holdover delay for input reference source 10MHz failure + is forever" + ::= { pt3080Input 8 } + +pt3080InputRef1PPSImpedance OBJECT-TYPE + SYNTAX INTEGER { o-50(0), himp(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the external 1 PPS input reference synchronisation source + impedance. The value is either 50ohm or high impedance." + ::= { pt3080Input 4 } + +pt3080InputRef1PPSHoldoverDelay OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 172800 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the external 1 PPS input reference synchronisation source + impedance. The value is either 50ohm or high impedance." + ::= { pt3080Input 9 } + +pt3080InputRef1PPSHoldoverForever OBJECT-TYPE + SYNTAX INTEGER { no(0), yes(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The holdover delay for input reference source 1 pps failure + is forever" + ::= { pt3080Input 10 } + +pt3080InputRef1PPSTrigSlope OBJECT-TYPE + SYNTAX INTEGER { rising(0), falling(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the trigger edge of the external 1PPS input reference + clock. The value is either RISING or FALLING." + ::= { pt3080Input 5 } + +pt3080InputRef1PPSTrigLevel OBJECT-TYPE + SYNTAX Integer32 ( 10 .. 16 ) + UNITS "0.1 v" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the trigger level of the external 1PPS input reference + clock" + ::= { pt3080Input 6 } + +pt3080InputASIAutoRoutingDelayHp2Lp OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 300 ) + UNITS "1 secs" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The delay before performing the actual substitution where TS-Primary + -> TS-LP and TS-Secondary -> TS-HP" + ::= { pt3080Input 15 } + +pt3080InputASIAutoRoutingDelayLp2Hp OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 300 ) + UNITS "1 secs" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The delay before performing the actual substitution where TS-Primary + -> TS-HP and TS-Secondary -> TS-LP" + ::= { pt3080Input 16 } + +pt3080InputASIHoldoverTimeout OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 3600 ) + UNITS "1 secs" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The time ASI Holdover will be active, if seamless ASI switching + is not possible" + ::= { pt3080Input 17 } + + +pt3080InputASITSPrimarySource OBJECT-TYPE + SYNTAX INTEGER { + asi-in-1(0), asi-in-2(1), + demodulator-1(2), demodulator-2(3), + tsoip-rx1(4), tsoip-rx2(5), + satRecv(6) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The TS-Primary input source connector selected" + ::= { pt3080Input 12 } + +pt3080InputASITSSecondarySource OBJECT-TYPE + SYNTAX INTEGER { + asi-in-1(0), asi-in-2(1), + demodulator-1(2), demodulator-2(3), + tsoip-rx1(4), tsoip-rx2(5), + satRecv(6) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The TS-Secondary input source connector selected" + ::= { pt3080Input 13 } + +pt3080InputASIAutoRoutingPolicy OBJECT-TYPE + SYNTAX INTEGER { only-use-primary(0), only-use-secondary(1), + use-primary-if-available(2), use-any-available(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The policy to use for TS auto routing" + ::= { pt3080Input 14 } + +pt3080InputTSPrimaryMaxPATDelay OBJECT-TYPE + SYNTAX Integer32 ( 10 .. 10000 ) + UNITS "1 ms" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Max delay between the Program Association Table (PAT) on + the incomming transport stream." + ::= { pt3080Input 18 } + +pt3080InputTSPrimaryMaxPATDelayEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables TS switching if the Max delay between PAT table updates + has been exceeded." + ::= { pt3080Input 19 } + +pt3080InputTSPrimaryExpectedTSID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The TS-ID value expected on the incoming TS stream." + ::= { pt3080Input 20 } + +pt3080InputTSPrimaryExpectedTSIDEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables TS switching if the TS-ID is not the expected value." + ::= { pt3080Input 21 } + +pt3080InputTSPrimaryExpectedNWID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The NW-ID value expected on the incoming TS stream." + ::= { pt3080Input 22 } + +pt3080InputTSPrimaryExpectedNWIDEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables TS switching if the NW-ID is not the expected value." + ::= { pt3080Input 23 } + +pt3080InputTSPrimaryMaxStuffingrate OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 100 ) + UNITS "1 %" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The expected stuffing rate on the incoming TS stream." + ::= { pt3080Input 24 } + +pt3080InputTSPrimaryMaxStuffingrateEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables TS switching if the Stuffing rate is over the expected + value." + ::= { pt3080Input 25 } + +pt3080InputTSPrimaryMinDelaymargin OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 1000 ) + UNITS "1 ms" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The minimum delay margin of the incoming TS stream." + ::= { pt3080Input 64 } + +pt3080InputTSPrimaryMinDelaymarginEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables TS switching if the Minimum Delay margin is not according + to the expected value." + ::= { pt3080Input 65 } + +pt3080InputTSPrimaryMaxMissingmip OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 255 ) + UNITS "1 secs" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The maximum seconds of missing mip information from the incoming + TS stream." + ::= { pt3080Input 68 } + +pt3080InputTSPrimaryMaxMissingmipEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables TS switching if the Maximum missing mip is not according + to the expected value." + ::= { pt3080Input 69 } + +pt3080InputTSSecondaryMaxPATDelay OBJECT-TYPE + SYNTAX Integer32 ( 10 .. 10000 ) + UNITS "1 ms" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Max delay between the Program Association Table (PAT) on + the incomming transport stream." + ::= { pt3080Input 27 } + +pt3080InputTSSecondaryMaxPATDelayEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables TS switching if the Max delay between PAT table updates + has been exceeded." + ::= { pt3080Input 28 } + +pt3080InputTSSecondaryExpectedTSID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The TS-ID value expected on the incoming TS stream." + ::= { pt3080Input 29 } + +pt3080InputTSSecondaryExpectedTSIDEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables TS switching if the TS-ID is not the expected value." + ::= { pt3080Input 30 } + +pt3080InputTSSecondaryExpectedNWID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The NW-ID value expected on the incoming TS stream." + ::= { pt3080Input 31 } + +pt3080InputTSSecondaryExpectedNWIDEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables TS switching if the NW-ID is not the expected value." + ::= { pt3080Input 32 } + +pt3080InputTSSecondaryMaxStuffingrate OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 100 ) + UNITS "1 %" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The expected stuffing rate on the incoming TS stream." + ::= { pt3080Input 33 } + +pt3080InputTSSecondaryMaxStuffingrateEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables TS switching if the Stuffing rate is over the expected + value." + ::= { pt3080Input 34 } + +pt3080InputTSSecondaryMinDelaymargin OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 1000 ) + UNITS "1 ms" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The minimum delay margin of the incoming TS stream." + ::= { pt3080Input 66 } + +pt3080InputTSSecondaryMinDelaymarginEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables TS switching if the Minimum Delay margin is not according + to the expected value." + ::= { pt3080Input 67 } + +pt3080InputTSSecondaryMaxMissingmip OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 255 ) + UNITS "1 secs" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The maximum seconds of missing mip information from the incoming + TS stream." + ::= { pt3080Input 73 } + +pt3080InputTSSecondaryMaxMissingmipEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables TS switching if the Maximum missing mip is not according + to the expected value." + ::= { pt3080Input 74 } + + +pt3080InputTSPrimaryMaxStsJitter OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 500 ) + UNITS "100ns" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Max STS jitter on the TS-Primary" + ::= { pt3080Input 26 } + + +pt3080InputTSSecondaryMaxStsJitter OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 500 ) + UNITS "100ns" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Max STS jitter on the TS-Secondary" + ::= { pt3080Input 35 } + +pt3080InputTSPrimaryStatus OBJECT-TYPE + SYNTAX INTEGER { available(0), unavailable(1), nosync(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current state for TS-Primary. Unavailable means violation of alarms." + ::= { pt3080Input 36 } + +pt3080InputTSSecondaryStatus OBJECT-TYPE + SYNTAX INTEGER { available(0), unavailable(1), nosync(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current state for TS-Secondary. Unavailable means violation of alarms." + ::= { pt3080Input 37 } + +pt3080InputTSHp OBJECT-TYPE + SYNTAX INTEGER { + asi-in-1(0), asi-in-2(1), + demodulator-1(2), demodulator-2(3), + tsoip-rx1(4), tsoip-rx2(5), + satRecv(6) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The input source currently On Air. (TS-HP)" + ::= { pt3080Input 38 } + +pt3080InputTSLp OBJECT-TYPE + SYNTAX INTEGER { + asi-in-1(0), asi-in-2(1), + demodulator-1(2), demodulator-2(3), + tsoip-rx1(4), tsoip-rx2(5), + satRecv(6) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The input source currently used as backup. (TS-LP)" + ::= { pt3080Input 39 } + +pt3080InputEffectiveAutoroutingPolicy OBJECT-TYPE + SYNTAX INTEGER { only-primary(0), only-secondary(1), prefer-primary(2), any-available(3), seamless(4) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Reflects the effective ASI Autorouting Policy" + ::= { pt3080Input 40 } + +pt3080InputTSHpBitrate OBJECT-TYPE + SYNTAX Integer32 + UNITS "Kb/s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current bitrate for On Air TS. (TS-HP)" + ::= { pt3080Input 41 } + +pt3080InputTSHpPacketsBuffered OBJECT-TYPE + SYNTAX Integer32 + UNITS "packets" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current number of packets buffered for On Air TS (TS-HP)" + ::= { pt3080Input 42 } + +pt3080InputTSHpPacketSize OBJECT-TYPE + SYNTAX Integer32 + UNITS "bytes" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current size of packets for On Air TS (TS-HP)" + ::= { pt3080Input 43 } + +pt3080InputTSHpStuffingrate OBJECT-TYPE + SYNTAX Integer32 + UNITS "Kb/s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current NULL stuffing as a percentage of the + current bitrate for On Air TS (TS-HP)" + ::= { pt3080Input 44 } + +pt3080InputTSHpTSID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current Transport Stream ID for On Air TS. (TS-HP)" + ::= { pt3080Input 45 } + +pt3080InputTSHpNWID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current Network ID for On Air TS. (TS-HP)" + ::= { pt3080Input 46 } + +pt3080InputTSLpBitrate OBJECT-TYPE + SYNTAX Integer32 + UNITS "Kb/s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current bitrate for Backup TS. (TS-LP)" + ::= { pt3080Input 47 } + +pt3080InputTSLpPacketsBuffered OBJECT-TYPE + SYNTAX Integer32 + UNITS "packets" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current number of packets buffered for Backup TS. (TS-LP)" + ::= { pt3080Input 48 } + +pt3080InputTSLpPacketSize OBJECT-TYPE + SYNTAX Integer32 + UNITS "bytes" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current size of packets for Backup TS. (TS-LP)" + ::= { pt3080Input 49 } + +pt3080InputTSLpStuffingrate OBJECT-TYPE + SYNTAX Integer32 + UNITS "Permille" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current NULL stuffing as a percentage of the + current bitrate for Backup TS. (TS-LP)" + ::= { pt3080Input 50 } + +pt3080InputTSLpTSID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current Transport Stream ID for Backup TS. (TS-LP)" + ::= { pt3080Input 51 } + +pt3080InputTSLpNWID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current Network ID for Backup TS. (TS-LP)" + ::= { pt3080Input 52 } + +pt3080InputTSPrimaryStsJitter OBJECT-TYPE + SYNTAX Integer32 + UNITS "100ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current STS jitter on the TS-Primary." + ::= { pt3080Input 53 } + +pt3080InputTSPrimaryStsJitterMax OBJECT-TYPE + SYNTAX Integer32 + UNITS "100ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Maximum STS jitter value seen on the TS-Primary" + ::= { pt3080Input 54 } + +pt3080InputTSPrimaryStsJitterMin OBJECT-TYPE + SYNTAX Integer32 + UNITS "100ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum STS jitter value seen on the TS-Primary" + ::= { pt3080Input 55 } + +pt3080InputTSPrimaryStsJitterReset OBJECT-TYPE + SYNTAX INTEGER { noop(0), reset-min-max(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reset the pt3080InputTSPrimaryStsJitterMax and pt3080InputTSPrimaryStsJitterMin values" + ::= { pt3080Input 56 } + +pt3080InputTSSecondaryStsJitter OBJECT-TYPE + SYNTAX Integer32 + UNITS "100ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current STS jitter on the TS-Secondary" + ::= { pt3080Input 57 } + +pt3080InputTSSecondaryStsJitterMax OBJECT-TYPE + SYNTAX Integer32 + UNITS "100ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Maximum STS jitter value seen on the TS-Secondary" + ::= { pt3080Input 58 } + +pt3080InputTSSecondaryStsJitterMin OBJECT-TYPE + SYNTAX Integer32 + UNITS "100ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum STS jitter value seen on the TS-Secondary" + ::= { pt3080Input 59 } + +pt3080InputTSSecondaryStsJitterReset OBJECT-TYPE + SYNTAX INTEGER { noop(0), reset-min-max(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reset the pt3080InputTSSecondaryStsJitterMax and + pt3080InputTSSecondaryStsJitterMin values" + ::= { pt3080Input 60 } + +-- +-- pt3080 Output sub-tree +-- + +pt3080OutputBandwidth OBJECT-TYPE + SYNTAX Integer32 ( 5 .. 8 ) + UNITS "MHz" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Output Bandwidth" + ::= { pt3080Output 4 } + +pt3080OutputChannel OBJECT-TYPE + SYNTAX Integer32 ( 21 .. 69 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Channel settings" + ::= { pt3080Output 5 } + +pt3080OutputSynchronized OBJECT-TYPE + SYNTAX INTEGER { not-synchronized(0), synchronized(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The values of pt3080OutputRfFrequency, pt3080OutputBandwidth and + pt3080OutputChannel are synchronized aaccording to + freq = (bw * channel) + 306000000." + ::= { pt3080Output 6 } + +pt3080OutputMute OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Output mute. When set the mute reason UserRequest is ORed into the mute reason set. + When read it is the logical OR of all mute reasons" + ::= { pt3080Output 7 } + +pt3080OutputPowerLevel OBJECT-TYPE + SYNTAX Integer32 ( 280 .. 490 ) + UNITS "0.1 dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The desired output power level." + ::= { pt3080Output 9 } + + +pt3080OutputIfEnable OBJECT-TYPE + SYNTAX INTEGER { no(0), yes(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control IF output" + ::= { pt3080Output 13 } + +pt3080OutputIfFrequency OBJECT-TYPE + SYNTAX Integer32 ( 35150000 .. 37150000 ) + UNITS "1 Hz" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Output Frequency for I/F" + ::= { pt3080Output 14 } + +pt3080OutputIfPolarity OBJECT-TYPE + SYNTAX INTEGER { norm(0), inv(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control IF output polarity" + ::= { pt3080Output 15 } + +pt3080OutputIfLevel OBJECT-TYPE + SYNTAX Integer32 ( -1000 .. 0 ) + UNITS "0.01 dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Output Level for I/F" + ::= { pt3080Output 16 } + +pt3080OutputMode OBJECT-TYPE + SYNTAX INTEGER { normal(0), standby(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control RF output mode" + ::= { pt3080Output 1 } + +pt3080OutputEffectiveLevel OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.01 dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Effective RF Output Level" + ::= { pt3080Output 17 } + +pt3080OutputActualLevel OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.01 dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual RF Output Level" + ::= { pt3080Output 18 } + +pt3080OutputPolarity OBJECT-TYPE + SYNTAX INTEGER { norm(0), inv(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control RF output polarity" + ::= { pt3080Output 8 } + +pt3080OutputRfFrequency OBJECT-TYPE + SYNTAX Integer32 ( 30000000 .. 860000000 ) + UNITS "1 Hz" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Output RF frequency" + ::= { pt3080Output 2 } + +pt3080OutputRfFrequencyOffset OBJECT-TYPE + SYNTAX Integer32 ( -8388608 .. 8388607 ) + UNITS "1 Hz" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Output RF frequency offset" + ::= { pt3080Output 10 } + +pt3080OutputRfLevel OBJECT-TYPE + SYNTAX Integer32 ( -1000 .. 1000 ) + UNITS "0.01 dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Sets the output level in 0.01dB steps, 0dB is +6dBm on IF, 0dBm + on RF" + ::= { pt3080Output 3 } + +pt3080OutputRfCableMode OBJECT-TYPE + SYNTAX INTEGER { none(0), const(1), auto(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control whether Cable Level loss compensation should be enabled" + ::= { pt3080Output 50 } + +pt3080OutputRfCableConstantLevelOffset OBJECT-TYPE + SYNTAX Integer32 ( -10000 .. 10000 ) + UNITS "0.001 dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Constant level offset to add to RF Output level. Only used if + mode is Constant." + ::= { pt3080Output 51 } + +pt3080OutputRfCableFrequencyLevelOffset0 OBJECT-TYPE + SYNTAX Integer32 ( -10000 .. 10000 ) + UNITS "0.001 dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Frequency depedent level offset to add to RF Output level. Only + used if mode is Automatic." + ::= { pt3080Output 52 } + +pt3080OutputRfCableFrequencyLevelOffset1 OBJECT-TYPE + SYNTAX Integer32 ( -10000 .. 10000 ) + UNITS "0.001 dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Frequency depedent level offset to add to RF Output level. Only + used if mode is Automatic." + ::= { pt3080Output 53 } + +pt3080OutputRfCableFrequencyLevelOffset2 OBJECT-TYPE + SYNTAX Integer32 ( -10000 .. 10000 ) + UNITS "0.001 dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Frequency depedent level offset to add to RF Output level. Only + used if mode is Automatic." + ::= { pt3080Output 54 } + +pt3080OutputRfCableFrequencyLevelOffset3 OBJECT-TYPE + SYNTAX Integer32 ( -10000 .. 10000 ) + UNITS "0.001 dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Frequency depedent level offset to add to RF Output level. Only + used if mode is Automatic." + ::= { pt3080Output 55 } + +pt3080OutputRfCableFrequencyLevelOffset4 OBJECT-TYPE + SYNTAX Integer32 ( -10000 .. 10000 ) + UNITS "0.001 dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Frequency depedent level offset to add to RF Output level. Only + used if mode is Automatic." + ::= { pt3080Output 56 } + +pt3080OutputRfCableFrequencyLevelOffset5 OBJECT-TYPE + SYNTAX Integer32 ( -10000 .. 10000 ) + UNITS "0.001 dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Frequency depedent level offset to add to RF Output level. Only + used if mode is Automatic." + ::= { pt3080Output 57 } + +pt3080OutputRfDetectedActualLevel OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.01 dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Detected Output Level for RF" + ::= { pt3080Output 19 } + +pt3080OutputRfDetectedLowerLevelLimit OBJECT-TYPE + SYNTAX Integer32 ( 2 .. 50 ) + UNITS "0.1 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Limit to how much lower the detected RF output level can be + than the configured level." + ::= { pt3080Output 20 } + +pt3080OutputRfDetectedLowerLevelcontrol OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether the lower limit for RF output level is enforced." + ::= { pt3080Output 21 } + +pt3080OutputRfDetectedHigherLevelLimit OBJECT-TYPE + SYNTAX Integer32 ( 2 .. 50 ) + UNITS "0.1 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Limit to how much higher the detected RF output level can be + than the configured level." + ::= { pt3080Output 22 } + +pt3080OutputRfDetectedHigherLevelcontrol OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether the higher limit for RF output level is enforced." + ::= { pt3080Output 23 } + +pt3080OutputRfAlcControl OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether the ALC system is enabled or disabled." + ::= { pt3080Output 30 } + +pt3080OutputRfAlcSense OBJECT-TYPE + SYNTAX INTEGER { rfsense1(0), rfsense2(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls which sense port is used by the ALC system if the ALC + is enabled." + ::= { pt3080Output 31 } + +pt3080OutputRfAlcSetpointPort1 OBJECT-TYPE + SYNTAX Integer32 ( -11000 .. 11000 ) + UNITS "0.01 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ALC setpoint for RF Sense Port 1" + ::= { pt3080Output 32 } + +pt3080OutputRfAlcSetpointPort2 OBJECT-TYPE + SYNTAX Integer32 ( -11000 .. 11000 ) + UNITS "0.01 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "ALC setpoint for RF Sense Port 2" + ::= { pt3080Output 33 } + +pt3080OutputRfAlcStatus OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status for whether the ALC system is enabled or disabled." + ::= { pt3080Output 34 } + +pt3080OutputRfAlcStatusInformation OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Information on the state of the ALC system." + ::= { pt3080Output 35 } + + +-- +-- pt3080 GPS sub-tree +-- + +pt3080GpsBias OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the bias to be either on or off for the GPS antenna + DC supply (5V or 3V DC). An active GPS antenna requires a power + supply i.e. requires this parameter to set to ON." + ::= { pt3080Gps 4 } + +pt3080GpsbiasVoltage OBJECT-TYPE + SYNTAX INTEGER { gpsant-5v(0), gpsant-33v(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the gps antenna bias voltage. An active GPS antenna + requires a power supply of either 3V or 5V." + ::= { pt3080Gps 15 } + +pt3080GpsCableDelay OBJECT-TYPE + SYNTAX Integer32 ( -18125 .. 13750 ) + UNITS "0.1 ns" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the antenna cable compensation delay. If the GPS antenna + is situated far away from the receiver itself the signal will + be delayed and must be compensated." + ::= { pt3080Gps 12 } + +pt3080GpsHoldoverForever OBJECT-TYPE + SYNTAX INTEGER { no(0), yes(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines whether the GPS system is allowed to operate infinitely + (YES) following loss of GPS locking using the internal GPS + chip oscillator or not (NO).In case NO is chosen the GPS holdover + time applies." + ::= { pt3080Gps 11 } + +pt3080GpsHoldoverTime OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 172800 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines the GPS holdover time. This value is ignored if the + holdover forever (see below) is set to YES If the GPS locking + is lost the system is allowed to continue operating for holdover + time seconds using the internal GPS chip oscillator. If - when + the holdover time interval expires - the GPS locking it still + lost, the GPS operation will be maintained using external timing + if present. If external timing is not present the GPS operation + will be maintained using the internal motherboard oscillator." + ::= { pt3080Gps 10 } + +pt3080GpsSatelliteSystemGPS OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether GPS satellites are used to obtain position + and timing information." + ::= { pt3080Gps 16 } + +pt3080GpsSatelliteSystemGLONASS OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether GLONASS satellites are used to obtain position + and timing information." + ::= { pt3080Gps 17 } + +pt3080GpsSatelliteSystemGALILEO OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether GALILEO satellites are used to obtain position + and timing information." + ::= { pt3080Gps 18 } + +pt3080GpsSatelliteSystemCOMPASS OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether COMPASS satellites are used to obtain position + and timing information." + ::= { pt3080Gps 19 } + +pt3080GpsVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Returns the GPS chip firmware version as a string." + ::= { pt3080Gps 9 } + +pt3080Gps1PPSStatus OBJECT-TYPE + SYNTAX INTEGER { locked(0), unlocked(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Returns the current locking state of the GPS system. The value + LOCKED indicates that the GPS system is locked to a sufficient + number of satellites to perform well. UNLOCKED indicates that + it is not. For the GPS system to perform well at least 4 satellites + must be visible with a proper signal to noise ratio." + ::= { pt3080Gps 1 } + +pt3080GpsState OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Returns a string describing the GPS state. For informational + purposes." + ::= { pt3080Gps 13 } + +pt3080GpsVisibleSatellitesSnr OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 dBHz" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Returns the average signal to noise ratio of all visible satellites + via the built-in GPS receiver" + ::= { pt3080Gps 14 } + +pt3080GpsVisibleSatellites OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Returns the number of currently visible satellites via the built-in + GPS receiver. A satellite is visible if at all detectable by + the GPS system i.e. regardless of signal to noise ratio. Note + that the upper value N can change with the launch of new satellites. + For some time, however, the GPS system has had a total of 24 + satellites." + ::= { pt3080Gps 2 } + +pt3080GpsTrackedSatellites OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Returns the number of currently tracked satellites via the GPS + receiver." + ::= { pt3080Gps 3 } + +pt3080GpsLongtitude OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Returns - as a string - the current longtitude derived from + the received GPS signal(s). The string format is DDD MM SS C. + according to the following: - DD denotes degrees in the intervals + [0 .. 180]. MM and SS denote minutes/seconds in the interval + [0 .. 59]. C denotes E, W (East, West)." + ::= { pt3080Gps 6 } + +pt3080GpsLatitude OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Returns - as a string - the current latitude derived from the + received GPS signal(s). The string format is DD MM SS C. according + to the following: - DD denotes degrees in the intervals [0 + .. 90]. MM and SS denote minutes/seconds in the interval [0 + .. 59]. C denotes N, S (North, South)." + ::= { pt3080Gps 7 } + +pt3080GpsAltitude OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Returns - as a string - the current altitude derived from the + received GPS signal(s). The string format is HHHH.c;. according + to the following: HHHH.c denotes the altitude in metres with + one digit after the comma. The altitude can be negative." + ::= { pt3080Gps 8 } + + +-- +-- pt3080 ChannelFilters sub-tree +-- + + + + +-- +-- Pt3080 TSoIP sub-tree +-- + +pt3080TSoIPRx1ReceiverEnable OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables the reception of IP/UDP packets with transport stream + data to be forward into the modulator." + ::= { pt3080TSoIP 15 } + +pt3080TSoIPRx2ReceiverEnable OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables the reception of IP/UDP packets with transport stream + data to be forward into the modulator." + ::= { pt3080TSoIP 45 } + +pt3080TSoIPRx1LanSelect OBJECT-TYPE + SYNTAX INTEGER { flan(0), alan(1), tlan(2), blan(3), plan(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies which virtual LAN interface to receive IP/UDP packets + from." + ::= { pt3080TSoIP 11 } + +pt3080TSoIPRx2LanSelect OBJECT-TYPE + SYNTAX INTEGER { flan(0), alan(1), tlan(2), blan(3), plan(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies which virtual LAN interface to receive IP/UDP packets + from." + ::= { pt3080TSoIP 41 } + +pt3080TSoIPRx1Multicast OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables the reception of Multicast IP/UDP packets with transport + stream data to be forward into the modulator. If disabled, + only unicast IP/UDP packets are considdered." + ::= { pt3080TSoIP 12 } + +pt3080TSoIPRx2Multicast OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables the reception of Multicast IP/UDP packets with transport + stream data to be forward into the modulator. If disabled, + only unicast IP/UDP packets are considdered." + ::= { pt3080TSoIP 42 } + +pt3080TSoIPRx1Protocol OBJECT-TYPE + SYNTAX INTEGER { udp(0), rtp(1), auto(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects which protocol to expect incoming packets to have." + ::= { pt3080TSoIP 13 } + +pt3080TSoIPRx2Protocol OBJECT-TYPE + SYNTAX INTEGER { udp(0), rtp(1), auto(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects which protocol to expect incoming packets to have." + ::= { pt3080TSoIP 43 } + +pt3080TSoIPRx1Portnumber OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies which UDP port number to receive IP/UDP packets from." + ::= { pt3080TSoIP 14 } + +pt3080TSoIPRx2Portnumber OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies which UDP port number to receive IP/UDP packets from." + ::= { pt3080TSoIP 44 } + +pt3080TSoIPRx1PacketErrorRatioLimit OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 500 ) + UNITS "0.1 %" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies limit for the Packet Error Ratio. If the limit is + exceeded and alarm is raised." + ::= { pt3080TSoIP 16 } + +pt3080TSoIPRx2PacketErrorRatioLimit OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 500 ) + UNITS "0.1 %" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies limit for the Packet Error Ratio. If the limit is + exceeded and alarm is raised." + ::= { pt3080TSoIP 46 } + +pt3080TSoIPRx1MinumimLatency OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 5000 ) + UNITS "0.1 ms" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies the minimum time incoming data is buffered. The value + configured might be modified by FEC row/column sized on the + incoming data." + ::= { pt3080TSoIP 10 } + +pt3080TSoIPRx2MinumimLatency OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 5000 ) + UNITS "0.1 ms" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies the minimum time incoming data is buffered. The value + configured might be modified by FEC row/column sized on the + incoming data." + ::= { pt3080TSoIP 40 } + +pt3080TSoIPRx1SyncTimeout OBJECT-TYPE + SYNTAX Integer32 ( 16 .. 250 ) + UNITS "1 ms" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies the maximum time accepted between received TS packages." + ::= { pt3080TSoIP 9 } + +pt3080TSoIPRx2SyncTimeout OBJECT-TYPE + SYNTAX Integer32 ( 16 .. 250 ) + UNITS "1 ms" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies the maximum time accepted between received TS packages." + ::= { pt3080TSoIP 39 } + +pt3080TSoIPRx1Status OBJECT-TYPE + SYNTAX INTEGER { locked(0), unlocked(1), disabled(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current status of the receiver. Locked means minimum of + 3 IP/UDP frames received per second." + ::= { pt3080TSoIP 17 } + +pt3080TSoIPRx2Status OBJECT-TYPE + SYNTAX INTEGER { locked(0), unlocked(1), disabled(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current status of the receiver. Locked means minimum of + 3 IP/UDP frames received per second." + ::= { pt3080TSoIP 47 } + +pt3080TSoIPRx1CurrentIPAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current receive IP address for the TSoIP interface." + ::= { pt3080TSoIP 18 } + +pt3080TSoIPRx2CurrentIPAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current receive IP address for the TSoIP interface." + ::= { pt3080TSoIP 48 } + +pt3080TSoIPRx1IpBitrate OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.001 Mbps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows the current bitrate of uncoming traffic for this UDP port." + ::= { pt3080TSoIP 26 } + +pt3080TSoIPRx2IpBitrate OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.001 Mbps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows the current bitrate of uncoming traffic for this UDP port." + ::= { pt3080TSoIP 56 } + +pt3080TSoIPRx1PacketErrorRatio OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 %" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows the current error ratio of uncoming traffic for this UDP + port." + ::= { pt3080TSoIP 20 } + +pt3080TSoIPRx2PacketErrorRatio OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 %" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows the current error ratio of uncoming traffic for this UDP + port." + ::= { pt3080TSoIP 50 } + +pt3080TSoIPRx1SequenceErrors OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of sequence errors on this channel on the TSoIP interface." + ::= { pt3080TSoIP 19 } + +pt3080TSoIPRx2SequenceErrors OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of sequence errors on this channel on the TSoIP interface." + ::= { pt3080TSoIP 49 } + +pt3080TSoIPRx1LostIPFrames OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of lost IP frames on the channel on the TSoIP interface. + The sequence numbers of frames employed by the RTP protocol + are used to determine this statistic." + ::= { pt3080TSoIP 21 } + +pt3080TSoIPRx2LostIPFrames OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of lost IP frames on the channel on the TSoIP interface. + The sequence numbers of frames employed by the RTP protocol + are used to determine this statistic." + ::= { pt3080TSoIP 51 } + +pt3080TSoIPRx1CorrectedIPFrames OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of corrected IP frames (via FEC) on this cannel on + the TSoIP interface." + ::= { pt3080TSoIP 22 } + +pt3080TSoIPRx2CorrectedIPFrames OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of corrected IP frames (via FEC) on this cannel on + the TSoIP interface." + ::= { pt3080TSoIP 52 } + +pt3080TSoIPRx1OverrunIPFrames OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of IP frames lost on the channel on the TSoIP interface + due to overrun. Overrun happens when the outgoing rate of the + modulator is lower that the incoming rate of TSoIP data." + ::= { pt3080TSoIP 30 } + +pt3080TSoIPRx2OverrunIPFrames OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of IP frames lost on the channel on the TSoIP interface + due to overrun. Overrun happens when the outgoing rate of the + modulator is lower that the incoming rate of TSoIP data." + ::= { pt3080TSoIP 60 } + +pt3080TSoIPRx1PacketsPerFrame OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The curent number of TS packets per IP frames on this cannel + on the TSoIP interface." + ::= { pt3080TSoIP 25 } + +pt3080TSoIPRx2PacketsPerFrame OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The curent number of TS packets per IP frames on this cannel + on the TSoIP interface." + ::= { pt3080TSoIP 55 } + +pt3080TSoIPRx1TSPacketSize OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The curent size of TS packets on this cannel on the TSoIP interface. + Usually 188 or 204." + ::= { pt3080TSoIP 29 } + +pt3080TSoIPRx2TSPacketSize OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The curent size of TS packets on this cannel on the TSoIP interface. + Usually 188 or 204." + ::= { pt3080TSoIP 59 } + +pt3080TSoIPRx1FecColumn OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The curent FEC Column (L) number for this cannel on the TSoIP + interface." + ::= { pt3080TSoIP 23 } + +pt3080TSoIPRx2FecColumn OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The curent FEC Column (L) number for this cannel on the TSoIP + interface." + ::= { pt3080TSoIP 53 } + +pt3080TSoIPRx1FecRow OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The curent FEC Row (D) number for this cannel on the TSoIP interface." + ::= { pt3080TSoIP 24 } + +pt3080TSoIPRx2FecRow OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The curent FEC Row (D) number for this cannel on the TSoIP interface." + ::= { pt3080TSoIP 54 } + +pt3080TSoIPRx1QueueSize OBJECT-TYPE + SYNTAX Integer32 + UNITS "1 Frames" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The curent queue size for this cannel on the TSoIP interface." + ::= { pt3080TSoIP 27 } + +pt3080TSoIPRx2QueueSize OBJECT-TYPE + SYNTAX Integer32 + UNITS "1 Frames" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The curent queue size for this cannel on the TSoIP interface." + ::= { pt3080TSoIP 57 } + +pt3080TSoIPRx1CurrentLatency OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 ms" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current latency incurrent by queue size on this channel + on the TSoIP interface." + ::= { pt3080TSoIP 28 } + +pt3080TSoIPRx2CurrentLatency OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 ms" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current latency incurrent by queue size on this channel + on the TSoIP interface." + ::= { pt3080TSoIP 58 } + + + +-- +-- pt3080 Monitor sub-tree +-- + +pt3080MonitorSource OBJECT-TYPE + SYNTAX INTEGER { asi-in1(0), asi-in2(1), aux1(2), aux2(3), tsoiprx1(4), tsoiprx2(5), ts-hp(6), ts-lp(7), backplane1(8), backplane2(9) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects the source to be monitored on the ASI monitor output." + ::= { pt3080Monitor 1 } + +pt3080MonitorTSoIPEnable OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable or disable the generation of monitor data over TSoIP." + ::= { pt3080Monitor 10 } + +pt3080MonitorTSoIPSource OBJECT-TYPE + SYNTAX INTEGER { asi-in1(0), asi-in2(1), aux1(2), aux2(3), tsoiprx1(4), tsoiprx2(5), ts-hp(6), ts-lp(7), backplane1(8), backplane2(9) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects the source to be monitored on the TSoIP monitor output." + ::= { pt3080Monitor 11 } + +pt3080MonitorTSoIPMulticastLanSelect OBJECT-TYPE + SYNTAX INTEGER { flan(0), alan(1), tlan(2), blan(3), plan(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies which virtual LAN interface to transmit Multicast + IP/UDP packets out via." + ::= { pt3080Monitor 25 } + +pt3080MonitorTSoIPDestIPAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects the destination IP address of the data to be monitored + on the TSoIP monitor output." + ::= { pt3080Monitor 12 } + +pt3080MonitorTSoIPDestPort OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects the destination UDP Port number of the data to be monitored + on the TSoIP monitor output." + ::= { pt3080Monitor 13 } + +pt3080MonitorTSoIPProtocol OBJECT-TYPE + SYNTAX INTEGER { udp(0), rtp(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects the protocol to be used on the TSoIP monitor output." + ::= { pt3080Monitor 14 } + +pt3080MonitorTSoIPEnableFec OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable or disable FEC protocol on the output data from the TSoIP + Monitor." + ::= { pt3080Monitor 15 } + +pt3080MonitorTSoIPFecColumn OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 20 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects the FEC protocoll Column number (L) of the data to be + monitored on the TSoIP monitor output." + ::= { pt3080Monitor 16 } + +pt3080MonitorTSoIPFecRow OBJECT-TYPE + SYNTAX Integer32 ( 4 .. 20 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects the FEC protocol Row number (D) of the data to be monitored + on the TSoIP monitor output." + ::= { pt3080Monitor 17 } + +pt3080MonitorTSoIPFecSkew OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 4 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects the FEC protocol Skew (non block alignment of FEC Frame) + of the data to be monitored on the TSoIP monitor output." + ::= { pt3080Monitor 18 } + +pt3080MonitorTSoIPKeepNullPackets OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Retain or discard Null packets of the generation of monitor + data over TSoIP." + ::= { pt3080Monitor 19 } + +pt3080MonitorTSoIPPacketsPerFrame OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 7 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Set the number of TS packets to send per IP frame on the TSoIP + monitor output." + ::= { pt3080Monitor 20 } + +pt3080MonitorTSoIPUDPChecksum OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Generate UDP checksum in the outgoing packets of the TSoIP Monitor." + ::= { pt3080Monitor 21 } + +pt3080MonitorTSoIPDSCP OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 255 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects the value of the TOS/DSCP field in IP packets to be + sent on the TSoIP monitor output." + ::= { pt3080Monitor 22 } + +pt3080MonitorTSoIPTTL OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 255 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects the value of the TTL (Time-To-Live) field in IP packets + to be sent on the TSoIP monitor output." + ::= { pt3080Monitor 23 } + +pt3080MonitorTSoIPGenerateError OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 1000 ) + UNITS "0.1 %" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Artificially generate an error rate as a percentage of frames + lost on the TSoIP monitor output." + ::= { pt3080Monitor 24 } + +pt3080MonitorTSoIPIpBitrate OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.001 Mbps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current rate IP packets traffic to be sent on the TSoIP + monitor output." + ::= { pt3080Monitor 30 } + +pt3080MonitorTSoIPTSSize OBJECT-TYPE + SYNTAX Integer32 + UNITS "1 bytes" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current TS packet size (188 or 204) on the TSoIP monitor + output." + ::= { pt3080Monitor 32 } + +pt3080MonitorTSoIPLostIPFrames OBJECT-TYPE + SYNTAX Integer32 + UNITS "1 Mbps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of IP packets traffic generated but lost on the TSoIP + monitor output." + ::= { pt3080Monitor 31 } + + +-- +-- pt3080 Test sub-tree +-- + +pt3080TestEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), scar(1), sweep2(2), prbs-on(3), prbs-auto(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "controls the test signal generation. This cannot be used when + network mode is SFN. Only a subset is available in repeater + mode. test signal output state: - testSignalsArray[testSignals_OFF] + Normal operation. No test signal. - testSignalsArray[testSignals_SCAR] + A single carrier output is provided. - testSignalsArray[testSignals_SWEEP2] + A test signal with full spectrum bandwidth and a 3dB peak to + average power ratio. (OFDM PPR-3). - testSignalsArray[testSignals_PRBSON] + Forced transmission of stuffing data only (null packets) irrespective + of the status of the MPEG-2 transport stream input. - testSignalsArray[testSignals_PRBSAUTO] + Automatic transmission of spectrum based on stuffing data when + no MPEG-2 TS input is available." + ::= { pt3080Test 1 } + +pt3080TestEnableReconnect OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether the test signal shall reconnect after reset. + This value is saved in non-volatile memory and thus survives + a reboot. - onOffArray[TEXT_INDEX_OFF] The selected test signal + will be set to OFF after reset. - onOffArray[TEXT_INDEX_ON] + The selected test signal will be output after reset." + ::= { pt3080Test 2 } + +pt3080TestScarrierLevel OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control level of the single carrier test signal." + ::= { pt3080Test 3 } + +pt3080TestscarrierFrequencyOffset OBJECT-TYPE + SYNTAX Integer32 ( -4000000 .. 4000000 ) + UNITS "1 Hz" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Control frequency offset of the single carrier test signal." + ::= { pt3080Test 4 } + + +-- +-- pt3080 Alarm sub-tree +-- + +-- Group Alarm table -- + +pt3080GroupAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pt3080GroupAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the group alarms" + ::= { pt3080Alarm 1 } + +pt3080GroupAlarmEntry OBJECT-TYPE + SYNTAX Pt3080GroupAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the alarms" + INDEX { pt3080GroupAlarmID } + ::= { pt3080GroupAlarmTable 1 } + +Pt3080GroupAlarmEntry ::= SEQUENCE { + pt3080GroupAlarmID Integer32, + pt3080GroupAlarmDescription DisplayString, + pt3080GroupAlarmState INTEGER, + pt3080GroupAlarmActionEventlog INTEGER, + pt3080GroupAlarmActionRelay1 INTEGER, + pt3080GroupAlarmActionRelay2 INTEGER, + pt3080GroupAlarmActionTrap INTEGER, + pt3080GroupAlarmActionEmail INTEGER, + pt3080GroupAlarmActionAlarmLED INTEGER, + pt3080GroupAlarmActionForceMode INTEGER +} + +pt3080GroupAlarmID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 255 ) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique ID for this alarm" + ::= { pt3080GroupAlarmEntry 1 } + +pt3080GroupAlarmDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description for this alarm" + ::= { pt3080GroupAlarmEntry 2 } + +pt3080GroupAlarmState OBJECT-TYPE + SYNTAX INTEGER { off(0), activated(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current GroupAlarm state condition" + ::= { pt3080GroupAlarmEntry 3 } + +pt3080GroupAlarmActionEventlog OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an event in the eventlog" + ::= { pt3080GroupAlarmEntry 4 } + +pt3080GroupAlarmActionRelay1 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay1" + ::= { pt3080GroupAlarmEntry 5 } + +pt3080GroupAlarmActionRelay2 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay2" + ::= { pt3080GroupAlarmEntry 6 } + +pt3080GroupAlarmActionTrap OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate a trap" + ::= { pt3080GroupAlarmEntry 7 } + +pt3080GroupAlarmActionEmail OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an email" + ::= { pt3080GroupAlarmEntry 8 } + +pt3080GroupAlarmActionAlarmLED OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm turn Alarm LED on frontpanel on" + ::= { pt3080GroupAlarmEntry 9 } + +pt3080GroupAlarmActionForceMode OBJECT-TYPE + SYNTAX INTEGER { none(0), mute(1), reboot(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm mute output" + ::= { pt3080GroupAlarmEntry 10 } + + + +-- ASI TS-Primary Alarm table -- + +pt3080ASITSPrimaryAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pt3080ASITSPrimaryAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the ASI TS-Primary alarms" + ::= { pt3080Alarm 5 } + +pt3080ASITSPrimaryAlarmEntry OBJECT-TYPE + SYNTAX Pt3080ASITSPrimaryAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the alarms" + INDEX { pt3080ASITSPrimaryAlarmID } + ::= { pt3080ASITSPrimaryAlarmTable 1 } + +Pt3080ASITSPrimaryAlarmEntry ::= SEQUENCE { + pt3080ASITSPrimaryAlarmID Integer32, + pt3080ASITSPrimaryAlarmDescription DisplayString, + pt3080ASITSPrimaryAlarmState INTEGER, + pt3080ASITSPrimaryAlarmActionEventlog INTEGER, + pt3080ASITSPrimaryAlarmActionRelay1 INTEGER, + pt3080ASITSPrimaryAlarmActionRelay2 INTEGER, + pt3080ASITSPrimaryAlarmActionTrap INTEGER, + pt3080ASITSPrimaryAlarmActionEmail INTEGER, + pt3080ASITSPrimaryAlarmActionAlarmLED INTEGER, + pt3080ASITSPrimaryAlarmActionForceMode INTEGER +} + +pt3080ASITSPrimaryAlarmID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 255 ) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique ID for this alarm" + ::= { pt3080ASITSPrimaryAlarmEntry 1 } + +pt3080ASITSPrimaryAlarmDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description for this alarm" + ::= { pt3080ASITSPrimaryAlarmEntry 2 } + +pt3080ASITSPrimaryAlarmState OBJECT-TYPE + SYNTAX INTEGER { off(0), activated(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current ASITSPrimaryAlarm state condition" + ::= { pt3080ASITSPrimaryAlarmEntry 3 } + +pt3080ASITSPrimaryAlarmActionEventlog OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an event in the eventlog" + ::= { pt3080ASITSPrimaryAlarmEntry 4 } + +pt3080ASITSPrimaryAlarmActionRelay1 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay1" + ::= { pt3080ASITSPrimaryAlarmEntry 5 } + +pt3080ASITSPrimaryAlarmActionRelay2 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay2" + ::= { pt3080ASITSPrimaryAlarmEntry 6 } + +pt3080ASITSPrimaryAlarmActionTrap OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate a trap" + ::= { pt3080ASITSPrimaryAlarmEntry 7 } + +pt3080ASITSPrimaryAlarmActionEmail OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an email" + ::= { pt3080ASITSPrimaryAlarmEntry 8 } + +pt3080ASITSPrimaryAlarmActionAlarmLED OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm turn Alarm LED on frontpanel on" + ::= { pt3080ASITSPrimaryAlarmEntry 9 } + +pt3080ASITSPrimaryAlarmActionForceMode OBJECT-TYPE + SYNTAX INTEGER { none(0), mute(1), reboot(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm mute output" + ::= { pt3080ASITSPrimaryAlarmEntry 10 } + +-- ASI TS-Secondary Alarm table -- + +pt3080ASITSSecondaryAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pt3080ASITSSecondaryAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the ASI alarms" + ::= { pt3080Alarm 6 } + +pt3080ASITSSecondaryAlarmEntry OBJECT-TYPE + SYNTAX Pt3080ASITSSecondaryAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the alarms" + INDEX { pt3080ASITSSecondaryAlarmID } + ::= { pt3080ASITSSecondaryAlarmTable 1 } + +Pt3080ASITSSecondaryAlarmEntry ::= SEQUENCE { + pt3080ASITSSecondaryAlarmID Integer32, + pt3080ASITSSecondaryAlarmDescription DisplayString, + pt3080ASITSSecondaryAlarmState INTEGER, + pt3080ASITSSecondaryAlarmActionEventlog INTEGER, + pt3080ASITSSecondaryAlarmActionRelay1 INTEGER, + pt3080ASITSSecondaryAlarmActionRelay2 INTEGER, + pt3080ASITSSecondaryAlarmActionTrap INTEGER, + pt3080ASITSSecondaryAlarmActionEmail INTEGER, + pt3080ASITSSecondaryAlarmActionAlarmLED INTEGER, + pt3080ASITSSecondaryAlarmActionForceMode INTEGER +} + +pt3080ASITSSecondaryAlarmID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 255 ) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique ID for this alarm" + ::= { pt3080ASITSSecondaryAlarmEntry 1 } + +pt3080ASITSSecondaryAlarmDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description for this alarm" + ::= { pt3080ASITSSecondaryAlarmEntry 2 } + +pt3080ASITSSecondaryAlarmState OBJECT-TYPE + SYNTAX INTEGER { off(0), activated(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current ASITSSecondaryAlarm state condition" + ::= { pt3080ASITSSecondaryAlarmEntry 3 } + +pt3080ASITSSecondaryAlarmActionEventlog OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an event in the eventlog" + ::= { pt3080ASITSSecondaryAlarmEntry 4 } + +pt3080ASITSSecondaryAlarmActionRelay1 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay1" + ::= { pt3080ASITSSecondaryAlarmEntry 5 } + +pt3080ASITSSecondaryAlarmActionRelay2 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay2" + ::= { pt3080ASITSSecondaryAlarmEntry 6 } + +pt3080ASITSSecondaryAlarmActionTrap OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate a trap" + ::= { pt3080ASITSSecondaryAlarmEntry 7 } + +pt3080ASITSSecondaryAlarmActionEmail OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an email" + ::= { pt3080ASITSSecondaryAlarmEntry 8 } + +pt3080ASITSSecondaryAlarmActionAlarmLED OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm turn Alarm LED on frontpanel on" + ::= { pt3080ASITSSecondaryAlarmEntry 9 } + +pt3080ASITSSecondaryAlarmActionForceMode OBJECT-TYPE + SYNTAX INTEGER { none(0), mute(1), reboot(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm mute output" + ::= { pt3080ASITSSecondaryAlarmEntry 10 } + +-- SFN Alarm table -- + +pt3080SFNAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pt3080SFNAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the SFN alarms" + ::= { pt3080Alarm 7 } + +pt3080SFNAlarmEntry OBJECT-TYPE + SYNTAX Pt3080SFNAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the alarms" + INDEX { pt3080SFNAlarmID } + ::= { pt3080SFNAlarmTable 1 } + +Pt3080SFNAlarmEntry ::= SEQUENCE { + pt3080SFNAlarmID Integer32, + pt3080SFNAlarmDescription DisplayString, + pt3080SFNAlarmState INTEGER, + pt3080SFNAlarmActionEventlog INTEGER, + pt3080SFNAlarmActionRelay1 INTEGER, + pt3080SFNAlarmActionRelay2 INTEGER, + pt3080SFNAlarmActionTrap INTEGER, + pt3080SFNAlarmActionEmail INTEGER, + pt3080SFNAlarmActionAlarmLED INTEGER, + pt3080SFNAlarmActionForceMode INTEGER +} + +pt3080SFNAlarmID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 255 ) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique ID for this alarm" + ::= { pt3080SFNAlarmEntry 1 } + +pt3080SFNAlarmDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description for this alarm" + ::= { pt3080SFNAlarmEntry 2 } + +pt3080SFNAlarmState OBJECT-TYPE + SYNTAX INTEGER { off(0), activated(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current SFNAlarm state condition" + ::= { pt3080SFNAlarmEntry 3 } + +pt3080SFNAlarmActionEventlog OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an event in the eventlog" + ::= { pt3080SFNAlarmEntry 4 } + +pt3080SFNAlarmActionRelay1 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay1" + ::= { pt3080SFNAlarmEntry 5 } + +pt3080SFNAlarmActionRelay2 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay2" + ::= { pt3080SFNAlarmEntry 6 } + +pt3080SFNAlarmActionTrap OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate a trap" + ::= { pt3080SFNAlarmEntry 7 } + +pt3080SFNAlarmActionEmail OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an email" + ::= { pt3080SFNAlarmEntry 8 } + +pt3080SFNAlarmActionAlarmLED OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm turn Alarm LED on frontpanel on" + ::= { pt3080SFNAlarmEntry 9 } + +pt3080SFNAlarmActionForceMode OBJECT-TYPE + SYNTAX INTEGER { none(0), mute(1), reboot(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm mute output" + ::= { pt3080SFNAlarmEntry 10 } + + + +-- Reference Alarm table -- + +pt3080ReferenceAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pt3080ReferenceAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the Reference alarms" + ::= { pt3080Alarm 8 } + +pt3080ReferenceAlarmEntry OBJECT-TYPE + SYNTAX Pt3080ReferenceAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the alarms" + INDEX { pt3080ReferenceAlarmID } + ::= { pt3080ReferenceAlarmTable 1 } + +Pt3080ReferenceAlarmEntry ::= SEQUENCE { + pt3080ReferenceAlarmID Integer32, + pt3080ReferenceAlarmDescription DisplayString, + pt3080ReferenceAlarmState INTEGER, + pt3080ReferenceAlarmActionEventlog INTEGER, + pt3080ReferenceAlarmActionRelay1 INTEGER, + pt3080ReferenceAlarmActionRelay2 INTEGER, + pt3080ReferenceAlarmActionTrap INTEGER, + pt3080ReferenceAlarmActionEmail INTEGER, + pt3080ReferenceAlarmActionAlarmLED INTEGER, + pt3080ReferenceAlarmActionForceMode INTEGER +} + +pt3080ReferenceAlarmID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 255 ) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique ID for this alarm" + ::= { pt3080ReferenceAlarmEntry 1 } + +pt3080ReferenceAlarmDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description for this alarm" + ::= { pt3080ReferenceAlarmEntry 2 } + +pt3080ReferenceAlarmState OBJECT-TYPE + SYNTAX INTEGER { off(0), activated(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current ReferenceAlarm state condition" + ::= { pt3080ReferenceAlarmEntry 3 } + +pt3080ReferenceAlarmActionEventlog OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an event in the eventlog" + ::= { pt3080ReferenceAlarmEntry 4 } + +pt3080ReferenceAlarmActionRelay1 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay1" + ::= { pt3080ReferenceAlarmEntry 5 } + +pt3080ReferenceAlarmActionRelay2 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay2" + ::= { pt3080ReferenceAlarmEntry 6 } + +pt3080ReferenceAlarmActionTrap OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate a trap" + ::= { pt3080ReferenceAlarmEntry 7 } + +pt3080ReferenceAlarmActionEmail OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an email" + ::= { pt3080ReferenceAlarmEntry 8 } + +pt3080ReferenceAlarmActionAlarmLED OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm turn Alarm LED on frontpanel on" + ::= { pt3080ReferenceAlarmEntry 9 } + +pt3080ReferenceAlarmActionForceMode OBJECT-TYPE + SYNTAX INTEGER { none(0), mute(1), reboot(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm mute output" + ::= { pt3080ReferenceAlarmEntry 10 } + + +-- RF Alarm table -- + +pt3080RFAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pt3080RFAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the RF alarms" + ::= { pt3080Alarm 9 } + +pt3080RFAlarmEntry OBJECT-TYPE + SYNTAX Pt3080RFAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the alarms" + INDEX { pt3080RFAlarmID } + ::= { pt3080RFAlarmTable 1 } + +Pt3080RFAlarmEntry ::= SEQUENCE { + pt3080RFAlarmID Integer32, + pt3080RFAlarmDescription DisplayString, + pt3080RFAlarmState INTEGER, + pt3080RFAlarmActionEventlog INTEGER, + pt3080RFAlarmActionRelay1 INTEGER, + pt3080RFAlarmActionRelay2 INTEGER, + pt3080RFAlarmActionTrap INTEGER, + pt3080RFAlarmActionEmail INTEGER, + pt3080RFAlarmActionAlarmLED INTEGER, + pt3080RFAlarmActionForceMode INTEGER +} + +pt3080RFAlarmID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 255 ) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique ID for this alarm" + ::= { pt3080RFAlarmEntry 1 } + +pt3080RFAlarmDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description for this alarm" + ::= { pt3080RFAlarmEntry 2 } + +pt3080RFAlarmState OBJECT-TYPE + SYNTAX INTEGER { off(0), activated(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current RFAlarm state condition" + ::= { pt3080RFAlarmEntry 3 } + +pt3080RFAlarmActionEventlog OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an event in the eventlog" + ::= { pt3080RFAlarmEntry 4 } + +pt3080RFAlarmActionRelay1 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay1" + ::= { pt3080RFAlarmEntry 5 } + +pt3080RFAlarmActionRelay2 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay2" + ::= { pt3080RFAlarmEntry 6 } + +pt3080RFAlarmActionTrap OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate a trap" + ::= { pt3080RFAlarmEntry 7 } + +pt3080RFAlarmActionEmail OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an email" + ::= { pt3080RFAlarmEntry 8 } + +pt3080RFAlarmActionAlarmLED OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm turn Alarm LED on frontpanel on" + ::= { pt3080RFAlarmEntry 9 } + +pt3080RFAlarmActionForceMode OBJECT-TYPE + SYNTAX INTEGER { none(0), mute(1), reboot(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm mute output" + ::= { pt3080RFAlarmEntry 10 } + +-- GPS Alarm table -- + +pt3080GPSAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pt3080GPSAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the GPS alarms" + ::= { pt3080Alarm 10 } + +pt3080GPSAlarmEntry OBJECT-TYPE + SYNTAX Pt3080GPSAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the alarms" + INDEX { pt3080GPSAlarmID } + ::= { pt3080GPSAlarmTable 1 } + +Pt3080GPSAlarmEntry ::= SEQUENCE { + pt3080GPSAlarmID Integer32, + pt3080GPSAlarmDescription DisplayString, + pt3080GPSAlarmState INTEGER, + pt3080GPSAlarmActionEventlog INTEGER, + pt3080GPSAlarmActionRelay1 INTEGER, + pt3080GPSAlarmActionRelay2 INTEGER, + pt3080GPSAlarmActionTrap INTEGER, + pt3080GPSAlarmActionEmail INTEGER, + pt3080GPSAlarmActionAlarmLED INTEGER, + pt3080GPSAlarmActionForceMode INTEGER +} + +pt3080GPSAlarmID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 255 ) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique ID for this alarm" + ::= { pt3080GPSAlarmEntry 1 } + +pt3080GPSAlarmDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description for this alarm" + ::= { pt3080GPSAlarmEntry 2 } + +pt3080GPSAlarmState OBJECT-TYPE + SYNTAX INTEGER { off(0), activated(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current GPSAlarm state condition" + ::= { pt3080GPSAlarmEntry 3 } + +pt3080GPSAlarmActionEventlog OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an event in the eventlog" + ::= { pt3080GPSAlarmEntry 4 } + +pt3080GPSAlarmActionRelay1 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay1" + ::= { pt3080GPSAlarmEntry 5 } + +pt3080GPSAlarmActionRelay2 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay2" + ::= { pt3080GPSAlarmEntry 6 } + +pt3080GPSAlarmActionTrap OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate a trap" + ::= { pt3080GPSAlarmEntry 7 } + +pt3080GPSAlarmActionEmail OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an email" + ::= { pt3080GPSAlarmEntry 8 } + +pt3080GPSAlarmActionAlarmLED OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm turn Alarm LED on frontpanel on" + ::= { pt3080GPSAlarmEntry 9 } + +pt3080GPSAlarmActionForceMode OBJECT-TYPE + SYNTAX INTEGER { none(0), mute(1), reboot(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm mute output" + ::= { pt3080GPSAlarmEntry 10 } + + +-- TSoIP Alarm table -- + +pt3080TSoIPAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pt3080TSoIPAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the TSoIP alarms" + ::= { pt3080Alarm 12 } + +pt3080TSoIPAlarmEntry OBJECT-TYPE + SYNTAX Pt3080TSoIPAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the alarms" + INDEX { pt3080TSoIPAlarmID } + ::= { pt3080TSoIPAlarmTable 1 } + +Pt3080TSoIPAlarmEntry ::= SEQUENCE { + pt3080TSoIPAlarmID Integer32, + pt3080TSoIPAlarmDescription DisplayString, + pt3080TSoIPAlarmState INTEGER, + pt3080TSoIPAlarmActionEventlog INTEGER, + pt3080TSoIPAlarmActionRelay1 INTEGER, + pt3080TSoIPAlarmActionRelay2 INTEGER, + pt3080TSoIPAlarmActionTrap INTEGER, + pt3080TSoIPAlarmActionEmail INTEGER, + pt3080TSoIPAlarmActionAlarmLED INTEGER, + pt3080TSoIPAlarmActionForceMode INTEGER +} + +pt3080TSoIPAlarmID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 255 ) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique ID for this alarm" + ::= { pt3080TSoIPAlarmEntry 1 } + +pt3080TSoIPAlarmDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description for this alarm" + ::= { pt3080TSoIPAlarmEntry 2 } + +pt3080TSoIPAlarmState OBJECT-TYPE + SYNTAX INTEGER { off(0), activated(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current TSoIPAlarm state condition" + ::= { pt3080TSoIPAlarmEntry 3 } + +pt3080TSoIPAlarmActionEventlog OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an event in the eventlog" + ::= { pt3080TSoIPAlarmEntry 4 } + +pt3080TSoIPAlarmActionRelay1 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay1" + ::= { pt3080TSoIPAlarmEntry 5 } + +pt3080TSoIPAlarmActionRelay2 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay2" + ::= { pt3080TSoIPAlarmEntry 6 } + +pt3080TSoIPAlarmActionTrap OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate a trap" + ::= { pt3080TSoIPAlarmEntry 7 } + +pt3080TSoIPAlarmActionEmail OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an email" + ::= { pt3080TSoIPAlarmEntry 8 } + +pt3080TSoIPAlarmActionAlarmLED OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm turn Alarm LED on frontpanel on" + ::= { pt3080TSoIPAlarmEntry 9 } + +pt3080TSoIPAlarmActionForceMode OBJECT-TYPE + SYNTAX INTEGER { none(0), mute(1), reboot(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm mute output" + ::= { pt3080TSoIPAlarmEntry 10 } + +-- External Alarm table -- + +pt3080ExternalAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pt3080ExternalAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the External alarms" + ::= { pt3080Alarm 13 } + +pt3080ExternalAlarmEntry OBJECT-TYPE + SYNTAX Pt3080ExternalAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the alarms" + INDEX { pt3080ExternalAlarmID } + ::= { pt3080ExternalAlarmTable 1 } + +Pt3080ExternalAlarmEntry ::= SEQUENCE { + pt3080ExternalAlarmID Integer32, + pt3080ExternalAlarmDescription DisplayString, + pt3080ExternalAlarmState INTEGER, + pt3080ExternalAlarmActionEventlog INTEGER, + pt3080ExternalAlarmActionRelay1 INTEGER, + pt3080ExternalAlarmActionRelay2 INTEGER, + pt3080ExternalAlarmActionTrap INTEGER, + pt3080ExternalAlarmActionEmail INTEGER, + pt3080ExternalAlarmActionAlarmLED INTEGER, + pt3080ExternalAlarmActionForceMode INTEGER +} + +pt3080ExternalAlarmID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 255 ) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique ID for this alarm" + ::= { pt3080ExternalAlarmEntry 1 } + +pt3080ExternalAlarmDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description for this alarm" + ::= { pt3080ExternalAlarmEntry 2 } + +pt3080ExternalAlarmState OBJECT-TYPE + SYNTAX INTEGER { off(0), activated(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current ExternalAlarm state condition" + ::= { pt3080ExternalAlarmEntry 3 } + +pt3080ExternalAlarmActionEventlog OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an event in the eventlog" + ::= { pt3080ExternalAlarmEntry 4 } + +pt3080ExternalAlarmActionRelay1 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay1" + ::= { pt3080ExternalAlarmEntry 5 } + +pt3080ExternalAlarmActionRelay2 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay2" + ::= { pt3080ExternalAlarmEntry 6 } + +pt3080ExternalAlarmActionTrap OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate a trap" + ::= { pt3080ExternalAlarmEntry 7 } + +pt3080ExternalAlarmActionEmail OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an email" + ::= { pt3080ExternalAlarmEntry 8 } + +pt3080ExternalAlarmActionAlarmLED OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm turn Alarm LED on frontpanel on" + ::= { pt3080ExternalAlarmEntry 9 } + +pt3080ExternalAlarmActionForceMode OBJECT-TYPE + SYNTAX INTEGER { none(0), mute(1), reboot(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm mute output" + ::= { pt3080ExternalAlarmEntry 10 } + +-- HW Monitor Alarm table -- + +pt3080HWMonitorAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pt3080HWMonitorAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the HW Monitor alarms" + ::= { pt3080Alarm 14 } + +pt3080HWMonitorAlarmEntry OBJECT-TYPE + SYNTAX Pt3080HWMonitorAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the alarms" + INDEX { pt3080HWMonitorAlarmID } + ::= { pt3080HWMonitorAlarmTable 1 } + +Pt3080HWMonitorAlarmEntry ::= SEQUENCE { + pt3080HWMonitorAlarmID Integer32, + pt3080HWMonitorAlarmDescription DisplayString, + pt3080HWMonitorAlarmState INTEGER, + pt3080HWMonitorAlarmActionEventlog INTEGER, + pt3080HWMonitorAlarmActionRelay1 INTEGER, + pt3080HWMonitorAlarmActionRelay2 INTEGER, + pt3080HWMonitorAlarmActionTrap INTEGER, + pt3080HWMonitorAlarmActionEmail INTEGER, + pt3080HWMonitorAlarmActionAlarmLED INTEGER, + pt3080HWMonitorAlarmActionForceMode INTEGER +} + +pt3080HWMonitorAlarmID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 255 ) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique ID for this alarm" + ::= { pt3080HWMonitorAlarmEntry 1 } + +pt3080HWMonitorAlarmDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description for this alarm" + ::= { pt3080HWMonitorAlarmEntry 2 } + +pt3080HWMonitorAlarmState OBJECT-TYPE + SYNTAX INTEGER { off(0), activated(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current HWMonitorAlarm state condition" + ::= { pt3080HWMonitorAlarmEntry 3 } + +pt3080HWMonitorAlarmActionEventlog OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an event in the eventlog" + ::= { pt3080HWMonitorAlarmEntry 4 } + +pt3080HWMonitorAlarmActionRelay1 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay1" + ::= { pt3080HWMonitorAlarmEntry 5 } + +pt3080HWMonitorAlarmActionRelay2 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay2" + ::= { pt3080HWMonitorAlarmEntry 6 } + +pt3080HWMonitorAlarmActionTrap OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate a trap" + ::= { pt3080HWMonitorAlarmEntry 7 } + +pt3080HWMonitorAlarmActionEmail OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an email" + ::= { pt3080HWMonitorAlarmEntry 8 } + +pt3080HWMonitorAlarmActionAlarmLED OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm turn Alarm LED on frontpanel on" + ::= { pt3080HWMonitorAlarmEntry 9 } + +pt3080HWMonitorAlarmActionForceMode OBJECT-TYPE + SYNTAX INTEGER { none(0), mute(1), reboot(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm mute output" + ::= { pt3080HWMonitorAlarmEntry 10 } + +-- Communications Alarm table -- + +pt3080CommsAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pt3080CommsAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the Communication alarms" + ::= { pt3080Alarm 15 } + +pt3080CommsAlarmEntry OBJECT-TYPE + SYNTAX Pt3080CommsAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the alarms" + INDEX { pt3080CommsAlarmID } + ::= { pt3080CommsAlarmTable 1 } + +Pt3080CommsAlarmEntry ::= SEQUENCE { + pt3080CommsAlarmID Integer32, + pt3080CommsAlarmDescription DisplayString, + pt3080CommsAlarmState INTEGER, + pt3080CommsAlarmActionEventlog INTEGER, + pt3080CommsAlarmActionRelay1 INTEGER, + pt3080CommsAlarmActionRelay2 INTEGER, + pt3080CommsAlarmActionTrap INTEGER, + pt3080CommsAlarmActionEmail INTEGER, + pt3080CommsAlarmActionAlarmLED INTEGER, + pt3080CommsAlarmActionForceMode INTEGER +} + +pt3080CommsAlarmID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 255 ) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique ID for this alarm" + ::= { pt3080CommsAlarmEntry 1 } + +pt3080CommsAlarmDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description for this alarm" + ::= { pt3080CommsAlarmEntry 2 } + +pt3080CommsAlarmState OBJECT-TYPE + SYNTAX INTEGER { off(0), activated(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current CommsAlarm state condition" + ::= { pt3080CommsAlarmEntry 3 } + +pt3080CommsAlarmActionEventlog OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an event in the eventlog" + ::= { pt3080CommsAlarmEntry 4 } + +pt3080CommsAlarmActionRelay1 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay1" + ::= { pt3080CommsAlarmEntry 5 } + +pt3080CommsAlarmActionRelay2 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay2" + ::= { pt3080CommsAlarmEntry 6 } + +pt3080CommsAlarmActionTrap OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate a trap" + ::= { pt3080CommsAlarmEntry 7 } + +pt3080CommsAlarmActionEmail OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an email" + ::= { pt3080CommsAlarmEntry 8 } + +pt3080CommsAlarmActionAlarmLED OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm turn Alarm LED on frontpanel on" + ::= { pt3080CommsAlarmEntry 9 } + +pt3080CommsAlarmActionForceMode OBJECT-TYPE + SYNTAX INTEGER { none(0), mute(1), reboot(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm mute output" + ::= { pt3080CommsAlarmEntry 10 } + +-- ASI Alarm table -- + +pt3080ASIAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pt3080ASIAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the ASI alarms" + ::= { pt3080Alarm 16 } + +pt3080ASIAlarmEntry OBJECT-TYPE + SYNTAX Pt3080ASIAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the alarms" + INDEX { pt3080ASIAlarmID } + ::= { pt3080ASIAlarmTable 1 } + +Pt3080ASIAlarmEntry ::= SEQUENCE { + pt3080ASIAlarmID Integer32, + pt3080ASIAlarmDescription DisplayString, + pt3080ASIAlarmState INTEGER, + pt3080ASIAlarmActionEventlog INTEGER, + pt3080ASIAlarmActionRelay1 INTEGER, + pt3080ASIAlarmActionRelay2 INTEGER, + pt3080ASIAlarmActionTrap INTEGER, + pt3080ASIAlarmActionEmail INTEGER, + pt3080ASIAlarmActionAlarmLED INTEGER, + pt3080ASIAlarmActionForceMode INTEGER +} + +pt3080ASIAlarmID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 255 ) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique ID for this alarm" + ::= { pt3080ASIAlarmEntry 1 } + +pt3080ASIAlarmDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description for this alarm" + ::= { pt3080ASIAlarmEntry 2 } + +pt3080ASIAlarmState OBJECT-TYPE + SYNTAX INTEGER { off(0), activated(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current ASIAlarm state condition" + ::= { pt3080ASIAlarmEntry 3 } + +pt3080ASIAlarmActionEventlog OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an event in the eventlog" + ::= { pt3080ASIAlarmEntry 4 } + +pt3080ASIAlarmActionRelay1 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay1" + ::= { pt3080ASIAlarmEntry 5 } + +pt3080ASIAlarmActionRelay2 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay2" + ::= { pt3080ASIAlarmEntry 6 } + +pt3080ASIAlarmActionTrap OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate a trap" + ::= { pt3080ASIAlarmEntry 7 } + +pt3080ASIAlarmActionEmail OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an email" + ::= { pt3080ASIAlarmEntry 8 } + +pt3080ASIAlarmActionAlarmLED OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm turn Alarm LED on frontpanel on" + ::= { pt3080ASIAlarmEntry 9 } + +pt3080ASIAlarmActionForceMode OBJECT-TYPE + SYNTAX INTEGER { none(0), mute(1), reboot(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm mute output" + ::= { pt3080ASIAlarmEntry 10 } + +-- Demodulator Alarm table -- + +pt3080DemodulatorAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pt3080DemodulatorAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the Demodulator alarms" + ::= { pt3080Alarm 17 } + +pt3080DemodulatorAlarmEntry OBJECT-TYPE + SYNTAX Pt3080DemodulatorAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the alarms" + INDEX { pt3080DemodulatorAlarmID } + ::= { pt3080DemodulatorAlarmTable 1 } + +Pt3080DemodulatorAlarmEntry ::= SEQUENCE { + pt3080DemodulatorAlarmID Integer32, + pt3080DemodulatorAlarmDescription DisplayString, + pt3080DemodulatorAlarmState INTEGER, + pt3080DemodulatorAlarmActionEventlog INTEGER, + pt3080DemodulatorAlarmActionRelay1 INTEGER, + pt3080DemodulatorAlarmActionRelay2 INTEGER, + pt3080DemodulatorAlarmActionTrap INTEGER, + pt3080DemodulatorAlarmActionEmail INTEGER, + pt3080DemodulatorAlarmActionAlarmLED INTEGER, + pt3080DemodulatorAlarmActionForceMode INTEGER +} + +pt3080DemodulatorAlarmID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 255 ) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique ID for this alarm" + ::= { pt3080DemodulatorAlarmEntry 1 } + +pt3080DemodulatorAlarmDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description for this alarm" + ::= { pt3080DemodulatorAlarmEntry 2 } + +pt3080DemodulatorAlarmState OBJECT-TYPE + SYNTAX INTEGER { off(0), activated(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current DemodulatorAlarm state condition" + ::= { pt3080DemodulatorAlarmEntry 3 } + +pt3080DemodulatorAlarmActionEventlog OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an event in the eventlog" + ::= { pt3080DemodulatorAlarmEntry 4 } + +pt3080DemodulatorAlarmActionRelay1 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay1" + ::= { pt3080DemodulatorAlarmEntry 5 } + +pt3080DemodulatorAlarmActionRelay2 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay2" + ::= { pt3080DemodulatorAlarmEntry 6 } + +pt3080DemodulatorAlarmActionTrap OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate a trap" + ::= { pt3080DemodulatorAlarmEntry 7 } + +pt3080DemodulatorAlarmActionEmail OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an email" + ::= { pt3080DemodulatorAlarmEntry 8 } + +pt3080DemodulatorAlarmActionAlarmLED OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm turn Alarm LED on frontpanel on" + ::= { pt3080DemodulatorAlarmEntry 9 } + +pt3080DemodulatorAlarmActionForceMode OBJECT-TYPE + SYNTAX INTEGER { none(0), mute(1), reboot(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm mute output" + ::= { pt3080DemodulatorAlarmEntry 10 } + +-- Internal Alarm table -- + +pt3080InternalAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pt3080InternalAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the Internal alarms" + ::= { pt3080Alarm 18 } + +pt3080InternalAlarmEntry OBJECT-TYPE + SYNTAX Pt3080InternalAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the alarms" + INDEX { pt3080InternalAlarmID } + ::= { pt3080InternalAlarmTable 1 } + +Pt3080InternalAlarmEntry ::= SEQUENCE { + pt3080InternalAlarmID Integer32, + pt3080InternalAlarmDescription DisplayString, + pt3080InternalAlarmState INTEGER, + pt3080InternalAlarmActionEventlog INTEGER, + pt3080InternalAlarmActionRelay1 INTEGER, + pt3080InternalAlarmActionRelay2 INTEGER, + pt3080InternalAlarmActionTrap INTEGER, + pt3080InternalAlarmActionEmail INTEGER, + pt3080InternalAlarmActionAlarmLED INTEGER, + pt3080InternalAlarmActionForceMode INTEGER +} + +pt3080InternalAlarmID OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 255 ) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique ID for this alarm" + ::= { pt3080InternalAlarmEntry 1 } + +pt3080InternalAlarmDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description for this alarm" + ::= { pt3080InternalAlarmEntry 2 } + +pt3080InternalAlarmState OBJECT-TYPE + SYNTAX INTEGER { off(0), activated(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current InternalAlarm state condition" + ::= { pt3080InternalAlarmEntry 3 } + +pt3080InternalAlarmActionEventlog OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an event in the eventlog" + ::= { pt3080InternalAlarmEntry 4 } + +pt3080InternalAlarmActionRelay1 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay1" + ::= { pt3080InternalAlarmEntry 5 } + +pt3080InternalAlarmActionRelay2 OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm activate relay2" + ::= { pt3080InternalAlarmEntry 6 } + +pt3080InternalAlarmActionTrap OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate a trap" + ::= { pt3080InternalAlarmEntry 7 } + +pt3080InternalAlarmActionEmail OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm generate an email" + ::= { pt3080InternalAlarmEntry 8 } + +pt3080InternalAlarmActionAlarmLED OBJECT-TYPE + SYNTAX INTEGER { disabled(0), enabled(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm turn Alarm LED on frontpanel on" + ::= { pt3080InternalAlarmEntry 9 } + +pt3080InternalAlarmActionForceMode OBJECT-TYPE + SYNTAX INTEGER { none(0), mute(1), reboot(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the current alarm mute output" + ::= { pt3080InternalAlarmEntry 10 } + + +-- DVB-T2 Mode-A Alarm table -- + + +-- +-- pt3080 Preset sub-tree +-- + +pt3080PresetTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pt3080PresetEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the presets" + ::= { pt3080Preset 1 } + +pt3080PresetEntry OBJECT-TYPE + SYNTAX Pt3080PresetEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the presets" + INDEX { pt3080PresetNo } + ::= { pt3080PresetTable 1 } + +Pt3080PresetEntry ::= SEQUENCE { + pt3080PresetNo Integer32, + pt3080PresetName DisplayString +} + +pt3080PresetNo OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 10 ) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique number for this preset" + ::= { pt3080PresetEntry 1 } + +pt3080PresetName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Name for this preset" + ::= { pt3080PresetEntry 2 } + +pt3080PresetRecall OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 10 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Install this preset into current running parameter set. + Value will always read as 0 and setting it to 0 has no effect." + ::= { pt3080Preset 2 } + +pt3080PresetStore OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 8 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Store the currently running parameter set into this preset + Value will always read as 0 and setting it to 0 has no effect." + ::= { pt3080Preset 3 } + +-- +-- pt3080 Eventlog sub-tree +-- + +pt3080EventlogTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pt3080EventlogEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the group alarms" + ::= { pt3080Eventlog 1 } + +pt3080EventlogEntry OBJECT-TYPE + SYNTAX Pt3080EventlogEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the alarms" + INDEX { pt3080EventlogNo } + ::= { pt3080EventlogTable 1 } + +Pt3080EventlogEntry ::= SEQUENCE { + pt3080EventlogNo Integer32, + pt3080EventlogID Integer32, + pt3080EventlogTimestamp DateAndTime, + pt3080EventlogText DisplayString +} + +pt3080EventlogNo OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 2047 ) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique number for this event" + ::= { pt3080EventlogEntry 1 } + +pt3080EventlogID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique ID for this type of event" + ::= { pt3080EventlogEntry 2 } + +pt3080EventlogTimestamp OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Timestamp for this event" + ::= { pt3080EventlogEntry 3 } + +pt3080EventlogText OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Text for this event" + ::= { pt3080EventlogEntry 4 } + +pt3080EventlogClear OBJECT-TYPE + SYNTAX INTEGER { noop(0), clear(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Clear the entire eventlog by setting the value to 1." + ::= { pt3080Eventlog 2 } + +pt3080EventlogEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable eventlog by setting the value to 1." + ::= { pt3080Eventlog 3 } + +pt3080EventlogMode OBJECT-TYPE + SYNTAX INTEGER { fifo(0), full(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Set eventlog mode to FIFO for keeping the newest entries. + Set eventlog mode to FULL for keeping the oldest entries." + ::= { pt3080Eventlog 4 } + +-- +-- pt3080 Comms sub-tree +-- + +pt3080CommsAlarmEmailReceiver OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The email address of the receipiant of alarm emails." + ::= { pt3080Comms 34 } + +pt3080CommsSeparatedSwitchPorts OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Will the ports on the switch in the backplane forward LAN traffic + to each other or will they be separated and only forward traffic + to/from the modulator/repeater." + ::= { pt3080Comms 98 } + +pt3080CommsBroadcastStormProtection OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable broadcast (and multicast) storm Protection. This + will limit the network ingress rate on physical Ethernet port + 0 and 1 to roughly 100mbit/s." + ::= { pt3080Comms 94 } + +pt3080CommsLocalPhysicalInterface OBJECT-TYPE + SYNTAX INTEGER { eth0(0), eth1(1), eth2(2), eth3(3), eth4(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Physical Ethernet Interface of this (virtual) interface." + ::= { pt3080Comms 80 } + +pt3080CommsLocalDhcpMode OBJECT-TYPE + SYNTAX INTEGER { off(0), client(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable DHCP client on this interface." + ::= { pt3080Comms 3 } + +pt3080CommsLocalStaticIpAddr OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The static IP address for this interface. Will be used if DHCP + is disabled or unavailable." + ::= { pt3080Comms 1 } + +pt3080CommsLocalStaticNetmask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The static IP netmask for this interface. Will be used if DHCP + is disabled or unavailable." + ::= { pt3080Comms 2 } + +pt3080CommsLocalIpMulticastAddr OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast address for this interface." + ::= { pt3080Comms 100 } + +pt3080CommsLocalIpMulticastSourceFilterMode OBJECT-TYPE + SYNTAX INTEGER { sfinclude(0), sfexclude(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies whether the Multicast Source Filter IP Address list + is: SFINCLUDE: ONLY receive multicast frames from the source + addresses in the list. SFEXCLUDE: Receive all multicast frames + EXCEPT from the source addresses in the list." + ::= { pt3080Comms 190 } + +pt3080CommsLocalIpMulticastSourceFilterAddress1 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 1 for this interface." + ::= { pt3080Comms 200 } + +pt3080CommsLocalIpMulticastSourceFilterAddress2 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 2 for this interface." + ::= { pt3080Comms 201 } + +pt3080CommsLocalIpMulticastSourceFilterAddress3 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 3 for this interface." + ::= { pt3080Comms 202 } + +pt3080CommsLocalIpMulticastSourceFilterAddress4 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 4 for this interface." + ::= { pt3080Comms 203 } + +pt3080CommsLocalIpMulticastSourceFilterAddress5 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 5 for this interface." + ::= { pt3080Comms 204 } + +pt3080CommsLocalIpMulticastSourceFilterAddress6 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 6 for this interface." + ::= { pt3080Comms 205 } + +pt3080CommsLocalVlanEnable OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable VLAN on this interface." + ::= { pt3080Comms 101 } + +pt3080CommsLocalVlanId OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 4095 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "VLAN ID to use on this interface, if VLAN is enabled. Please + note that VLAN ID 4001 and 4002 are used for internal switching + and thus cannot be used on any interface." + ::= { pt3080Comms 102 } + +pt3080CommsLocalServiceSNMP OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable SNMP service on this interface." + ::= { pt3080Comms 103 } + +pt3080CommsLocalServiceSCPI OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable SCPI service on this interface." + ::= { pt3080Comms 104 } + +pt3080CommsLocalServiceTSoIP OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable TSoIP service on this interface." + ::= { pt3080Comms 105 } + +pt3080CommsLocalServiceRIP OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable RIP service on this interface." + ::= { pt3080Comms 106 } + +pt3080CommsLocalCurrentIpAddr OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current IP address for this interface." + ::= { pt3080Comms 4 } + +pt3080CommsLocalCurrentNetmask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current IP netmask for this interface." + ::= { pt3080Comms 5 } + +pt3080CommsRemoteEnable OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable this interface." + ::= { pt3080Comms 117 } + +pt3080CommsRemotePhysicalInterface OBJECT-TYPE + SYNTAX INTEGER { eth0(0), eth1(1), eth2(2), eth3(3), eth4(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Physical Ethernet Interface of this (virtual) interface." + ::= { pt3080Comms 81 } + +pt3080CommsRemoteDhcpMode OBJECT-TYPE + SYNTAX INTEGER { off(0), client(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable DHCP client on this interface." + ::= { pt3080Comms 73 } + +pt3080CommsRemoteStaticIpAddr OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The static IP address for this interface. Will be used if DHCP + is disabled or unavailable." + ::= { pt3080Comms 7 } + +pt3080CommsRemoteStaticNetmask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The static IP netmask for this interface. Will be used if DHCP + is disabled or unavailable." + ::= { pt3080Comms 8 } + +pt3080CommsRemoteIpMulticastAddr OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast address for this interface." + ::= { pt3080Comms 110 } + +pt3080CommsRemoteIpMulticastSourceFilterMode OBJECT-TYPE + SYNTAX INTEGER { sfinclude(0), sfexclude(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies whether the Multicast Source Filter IP Address list + is: SFINCLUDE: ONLY receive multicast frames from the source + addresses in the list. SFEXCLUDE: Receive all multicast frames + EXCEPT from the source addresses in the list." + ::= { pt3080Comms 191 } + +pt3080CommsRemoteIpMulticastSourceFilterAddress1 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 1 for this interface." + ::= { pt3080Comms 220 } + +pt3080CommsRemoteIpMulticastSourceFilterAddress2 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 2 for this interface." + ::= { pt3080Comms 221 } + +pt3080CommsRemoteIpMulticastSourceFilterAddress3 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 3 for this interface." + ::= { pt3080Comms 222 } + +pt3080CommsRemoteIpMulticastSourceFilterAddress4 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 4 for this interface." + ::= { pt3080Comms 223 } + +pt3080CommsRemoteIpMulticastSourceFilterAddress5 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 5 for this interface." + ::= { pt3080Comms 224 } + +pt3080CommsRemoteIpMulticastSourceFilterAddress6 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 6 for this interface." + ::= { pt3080Comms 225 } + +pt3080CommsRemoteVlanEnable OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable VLAN on this interface." + ::= { pt3080Comms 111 } + +pt3080CommsRemoteVlanId OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 4095 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "VLAN ID to use on this interface, if VLAN is enabled. Please + note that VLAN ID 4001 and 4002 are used for internal switching + and thus cannot be used on any interface." + ::= { pt3080Comms 112 } + +pt3080CommsRemoteServiceSNMP OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable SNMP service on this interface." + ::= { pt3080Comms 113 } + +pt3080CommsRemoteServiceSCPI OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable SCPI service on this interface." + ::= { pt3080Comms 114 } + +pt3080CommsRemoteServiceTSoIP OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable TSoIP service on this interface." + ::= { pt3080Comms 115 } + +pt3080CommsRemoteServiceWeb OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable WEB (http) service on this interface." + ::= { pt3080Comms 116 } + +pt3080CommsRemoteServiceRIP OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable RIP service on this interface." + ::= { pt3080Comms 118 } + +pt3080CommsRemoteCurrentIpAddr OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current IP address for this interface." + ::= { pt3080Comms 10 } + +pt3080CommsRemoteCurrentNetmask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current IP netmask for this interface." + ::= { pt3080Comms 11 } + +pt3080CommsGbeAdminEnable OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable this interface." + ::= { pt3080Comms 127 } + +pt3080CommsGbeAdminPhysicalInterface OBJECT-TYPE + SYNTAX INTEGER { eth0(0), eth1(1), eth2(2), eth3(3), eth4(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Physical Ethernet Interface of this (virtual) interface." + ::= { pt3080Comms 82 } + +pt3080CommsGbeAdminDhcpMode OBJECT-TYPE + SYNTAX INTEGER { off(0), client(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable DHCP client on this interface." + ::= { pt3080Comms 74 } + +pt3080CommsGbeAdminStaticIpAddr OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The static IP address for this interface. Will be used if DHCP + is disabled or unavailable." + ::= { pt3080Comms 13 } + +pt3080CommsGbeAdminStaticNetmask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The static IP netmask for this interface. Will be used if DHCP + is disabled or unavailable." + ::= { pt3080Comms 14 } + +pt3080CommsGbeAdminIpMulticastAddr OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast address for this interface." + ::= { pt3080Comms 120 } + +pt3080CommsGbeAdminIpMulticastSourceFilterMode OBJECT-TYPE + SYNTAX INTEGER { sfinclude(0), sfexclude(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies whether the Multicast Source Filter IP Address list + is: SFINCLUDE: ONLY receive multicast frames from the source + addresses in the list. SFEXCLUDE: Receive all multicast frames + EXCEPT from the source addresses in the list." + ::= { pt3080Comms 192 } + +pt3080CommsGbeAdminIpMulticastSourceFilterAddress1 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 1 for this interface." + ::= { pt3080Comms 230 } + +pt3080CommsGbeAdminIpMulticastSourceFilterAddress2 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 2 for this interface." + ::= { pt3080Comms 231 } + +pt3080CommsGbeAdminIpMulticastSourceFilterAddress3 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 3 for this interface." + ::= { pt3080Comms 232 } + +pt3080CommsGbeAdminIpMulticastSourceFilterAddress4 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 4 for this interface." + ::= { pt3080Comms 233 } + +pt3080CommsGbeAdminIpMulticastSourceFilterAddress5 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 5 for this interface." + ::= { pt3080Comms 234 } + +pt3080CommsGbeAdminIpMulticastSourceFilterAddress6 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 6 for this interface." + ::= { pt3080Comms 235 } + +pt3080CommsGbeAdminVlanEnable OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable VLAN on this interface." + ::= { pt3080Comms 121 } + +pt3080CommsGbeAdminVlanId OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 4095 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "VLAN ID to use on this interface, if VLAN is enabled. Please + note that VLAN ID 4001 and 4002 are used for internal switching + and thus cannot be used on any interface." + ::= { pt3080Comms 122 } + +pt3080CommsGbeAdminServiceSNMP OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable SNMP service on this interface." + ::= { pt3080Comms 123 } + +pt3080CommsGbeAdminServiceSCPI OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable SCPI service on this interface." + ::= { pt3080Comms 124 } + +pt3080CommsGbeAdminServiceTSoIP OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable TSoIP service on this interface." + ::= { pt3080Comms 125 } + +pt3080CommsGbeAdminServiceWeb OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable Web (http) service on this interface." + ::= { pt3080Comms 126 } + +pt3080CommsGbeAdminServiceRIP OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable RIP service on this interface." + ::= { pt3080Comms 128 } + +pt3080CommsGbeAdminCurrentIpAddr OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current IP address for this interface." + ::= { pt3080Comms 16 } + +pt3080CommsGbeAdminCurrentNetmask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current IP netmask for this interface." + ::= { pt3080Comms 17 } + +pt3080CommsBackupEnable OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable this interface." + ::= { pt3080Comms 150 } + +pt3080CommsBackupPhysicalInterface OBJECT-TYPE + SYNTAX INTEGER { eth0(0), eth1(1), eth2(2), eth3(3), eth4(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Physical Ethernet Interface of this (virtual) interface." + ::= { pt3080Comms 151 } + +pt3080CommsBackupDhcpMode OBJECT-TYPE + SYNTAX INTEGER { off(0), client(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable DHCP client on this interface." + ::= { pt3080Comms 75 } + +pt3080CommsBackupStaticIpAddr OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The static IP address for this interface. Will be used if DHCP + is disabled or unavailable." + ::= { pt3080Comms 152 } + +pt3080CommsBackupStaticNetmask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The static IP netmask for this interface. Will be used if DHCP + is disabled or unavailable." + ::= { pt3080Comms 153 } + +pt3080CommsBackupIpMulticastAddr OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast address for this interface." + ::= { pt3080Comms 154 } + +pt3080CommsBackupIpMulticastSourceFilterMode OBJECT-TYPE + SYNTAX INTEGER { sfinclude(0), sfexclude(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies whether the Multicast Source Filter IP Address list + is: SFINCLUDE: ONLY receive multicast frames from the source + addresses in the list. SFEXCLUDE: Receive all multicast frames + EXCEPT from the source addresses in the list." + ::= { pt3080Comms 193 } + +pt3080CommsBackupIpMulticastSourceFilterAddress1 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 1 for this interface." + ::= { pt3080Comms 170 } + +pt3080CommsBackupIpMulticastSourceFilterAddress2 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 2 for this interface." + ::= { pt3080Comms 171 } + +pt3080CommsBackupIpMulticastSourceFilterAddress3 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 3 for this interface." + ::= { pt3080Comms 172 } + +pt3080CommsBackupIpMulticastSourceFilterAddress4 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 4 for this interface." + ::= { pt3080Comms 173 } + +pt3080CommsBackupIpMulticastSourceFilterAddress5 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 5 for this interface." + ::= { pt3080Comms 174 } + +pt3080CommsBackupIpMulticastSourceFilterAddress6 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 6 for this interface." + ::= { pt3080Comms 175 } + +pt3080CommsBackupVlanEnable OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable VLAN on this interface." + ::= { pt3080Comms 155 } + +pt3080CommsBackupVlanId OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 4095 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "VLAN ID to use on this interface, if VLAN is enabled. Please + note that VLAN ID 4001 and 4002 are used for internal switching + and thus cannot be used on any interface." + ::= { pt3080Comms 156 } + +pt3080CommsBackupServiceSNMP OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable SNMP service on this interface." + ::= { pt3080Comms 157 } + +pt3080CommsBackupServiceSCPI OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable SCPI service on this interface." + ::= { pt3080Comms 158 } + +pt3080CommsBackupServiceTSoIP OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable TSoIP service on this interface." + ::= { pt3080Comms 159 } + +pt3080CommsBackupServiceWeb OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable Web (http) service on this interface." + ::= { pt3080Comms 160 } + +pt3080CommsBackupServiceRIP OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable RIP service on this interface." + ::= { pt3080Comms 161 } + +pt3080CommsBackupCurrentIpAddr OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current IP address for this interface." + ::= { pt3080Comms 162 } + +pt3080CommsBackupCurrentNetmask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current IP netmask for this interface." + ::= { pt3080Comms 163 } + +pt3080CommsPortEnable OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable this interface." + ::= { pt3080Comms 2500 } + +pt3080CommsPortPhysicalInterface OBJECT-TYPE + SYNTAX INTEGER { eth0(0), eth1(1), eth2(2), eth3(3), eth4(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Physical Ethernet Interface of this (virtual) interface." + ::= { pt3080Comms 2151 } + +pt3080CommsPortDhcpMode OBJECT-TYPE + SYNTAX INTEGER { off(0), client(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable DHCP client on this interface." + ::= { pt3080Comms 2075 } + +pt3080CommsPortStaticIpAddr OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The static IP address for this interface. Will be used if DHCP + is disabled or unavailable." + ::= { pt3080Comms 2152 } + +pt3080CommsPortStaticNetmask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The static IP netmask for this interface. Will be used if DHCP + is disabled or unavailable." + ::= { pt3080Comms 2153 } + +pt3080CommsPortIpMulticastAddr OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast address for this interface." + ::= { pt3080Comms 2154 } + +pt3080CommsPortIpMulticastSourceFilterMode OBJECT-TYPE + SYNTAX INTEGER { sfinclude(0), sfexclude(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Specifies whether the Multicast Source Filter IP Address list + is: SFINCLUDE: ONLY receive multicast frames from the source + addresses in the list. SFEXCLUDE: Receive all multicast frames + EXCEPT from the source addresses in the list." + ::= { pt3080Comms 2193 } + +pt3080CommsPortIpMulticastSourceFilterAddress1 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 1 for this interface." + ::= { pt3080Comms 2170 } + +pt3080CommsPortIpMulticastSourceFilterAddress2 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 2 for this interface." + ::= { pt3080Comms 2171 } + +pt3080CommsPortIpMulticastSourceFilterAddress3 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 3 for this interface." + ::= { pt3080Comms 2172 } + +pt3080CommsPortIpMulticastSourceFilterAddress4 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 4 for this interface." + ::= { pt3080Comms 2173 } + +pt3080CommsPortIpMulticastSourceFilterAddress5 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 5 for this interface." + ::= { pt3080Comms 2174 } + +pt3080CommsPortIpMulticastSourceFilterAddress6 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP Multicast Source Filter address no 6 for this interface." + ::= { pt3080Comms 2175 } + +pt3080CommsPortVlanEnable OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable VLAN on this interface." + ::= { pt3080Comms 2155 } + +pt3080CommsPortVlanId OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 4095 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "VLAN ID to use on this interface, if VLAN is enabled. Please + note that VLAN ID 4001 and 4002 are used for internal switching + and thus cannot be used on any interface." + ::= { pt3080Comms 2156 } + +pt3080CommsPortServiceSNMP OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable SNMP service on this interface." + ::= { pt3080Comms 2157 } + +pt3080CommsPortServiceSCPI OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable SCPI service on this interface." + ::= { pt3080Comms 2158 } + +pt3080CommsPortServiceTSoIP OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable TSoIP service on this interface." + ::= { pt3080Comms 2159 } + +pt3080CommsPortServiceWeb OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable Web (http) service on this interface." + ::= { pt3080Comms 2160 } + +pt3080CommsPortServiceRIP OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable RIP service on this interface." + ::= { pt3080Comms 2161 } + +pt3080CommsPortCurrentIpAddr OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current IP address for this interface." + ::= { pt3080Comms 2162 } + +pt3080CommsPortCurrentNetmask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current IP netmask for this interface." + ::= { pt3080Comms 2163 } + +pt3080CommsSNMPServicePort OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The UDP port number used for SNMP Service." + ::= { pt3080Comms 55 } + +pt3080CommsSNMPReadOnlyCommunity OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Read-only community string used to access the SNMP Service." + ::= { pt3080Comms 56 } + +pt3080CommsSNMPReadWriteCommunity OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Read-Write community string used to access the SNMP Service." + ::= { pt3080Comms 57 } + +pt3080CommsSNMPTrapCommunity OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Trap community string used when sending SNMP Traps." + ::= { pt3080Comms 58 } + +pt3080CommsSNMPTrapDestination OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The destination IP address for the SNMP traps." + ::= { pt3080Comms 59 } + +pt3080CommsSNMPTrapDestination2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The destination 2 IP address for the SNMP traps." + ::= { pt3080Comms 419 } + +pt3080CommsSNMPTrapDestination3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The destination 3 IP address for the SNMP traps." + ::= { pt3080Comms 779 } + +pt3080CommsSNMPTrapDestination4 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The destination 4 IP address for the SNMP traps." + ::= { pt3080Comms 1139 } + +pt3080CommsSNMPTrapDestination5 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The destination 5 IP address for the SNMP traps." + ::= { pt3080Comms 1499 } + +pt3080CommsSNMPTrapDestinationPort OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The UDP port number used for Trap destination ." + ::= { pt3080Comms 60 } + +pt3080CommsSNMPTrapDestinationPort2 OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The UDP port number used for Trap destination 2." + ::= { pt3080Comms 420 } + +pt3080CommsSNMPTrapDestinationPort3 OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The UDP port number used for Trap destination 3." + ::= { pt3080Comms 780 } + +pt3080CommsSNMPTrapDestinationPort4 OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The UDP port number used for Trap destination 4." + ::= { pt3080Comms 1140 } + +pt3080CommsSNMPTrapDestinationPort5 OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The UDP port number used for Trap destination 5." + ::= { pt3080Comms 1500 } + +pt3080CommsStaticGateway OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The static IP address for the default router (gateway). Will + be used unless DHCP is enabled and the DHCP server is configured + to include a default router address." + ::= { pt3080Comms 29 } + +pt3080CommsCurrentGateway OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Current IP address for the default router (gateway)." + ::= { pt3080Comms 30 } + +pt3080CommsStaticHostname OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The static hostname for the device. Will be used if DHCP is + disabled or unavailable." + ::= { pt3080Comms 27 } + +pt3080CommsCurrentHostname OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The static hostname for the device. Will be used if DHCP is + disabled or unavailable." + ::= { pt3080Comms 28 } + +pt3080CommsStaticDNSDomain OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The static DNS domain name for the device. Will be used if DHCP + is disabled or unavailable." + ::= { pt3080Comms 25 } + +pt3080CommsCurrentDNSDomain OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current DNS domain name for the device." + ::= { pt3080Comms 26 } + +pt3080CommsStaticDNS1ServerAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP address of DNS server 1." + ::= { pt3080Comms 19 } + +pt3080CommsStaticDNS2ServerAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP address of DNS server 2." + ::= { pt3080Comms 21 } + +pt3080CommsStaticDNS3ServerAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP address of DNS server 3." + ::= { pt3080Comms 23 } + +pt3080CommsCurrentDNS1ServerAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Current IP address of DNS server 1." + ::= { pt3080Comms 20 } + +pt3080CommsCurrentDNS2ServerAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Current IP address of DNS server 2." + ::= { pt3080Comms 22 } + +pt3080CommsCurrentDNS3ServerAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Current IP address of DNS server 3." + ::= { pt3080Comms 24 } + +pt3080CommsStaticNtpServerAddress OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The DNS name or IP address of the NTP server." + ::= { pt3080Comms 31 } + +pt3080CommsCurrentNtpServerAddress OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Current IP address of the NTP server." + ::= { pt3080Comms 32 } + +pt3080CommsEmailServerAddress OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP address of the Email (SMTP) server." + ::= { pt3080Comms 33 } + +pt3080CommsWebServicePort OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The TCP port number used for Web Service." + ::= { pt3080Comms 35 } + +pt3080CommsSCPIServicePort OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The TCP port number used for SCPI Service." + ::= { pt3080Comms 36 } + +pt3080CommsSCPIServerBaudrate OBJECT-TYPE + SYNTAX INTEGER { r2400(0), r4800(1), r9600(2), r19200(3), r38400(4), r57600(5), r115200(6) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Baudrate used for SCPI Service on serial port." + ::= { pt3080Comms 37 } + +pt3080CommsSCPIUartInterface OBJECT-TYPE + SYNTAX INTEGER { rs232(0), rs485(1), rs485hd(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Interface used for SCPI Service on serial port." + ::= { pt3080Comms 39 } + +pt3080CommsRipPort OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 65535 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The UDP port number used for RIP Service." + ::= { pt3080Comms 38 } + +pt3080CommsIGMPVersion OBJECT-TYPE + SYNTAX INTEGER { auto(0), v1(1), v2(2), v3(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Select which IGMP Version to use." + ::= { pt3080Comms 99 } + +pt3080CommsIGMPQueryRobustnessCount OBJECT-TYPE + SYNTAX Integer32 ( 2 .. 16 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Number of Query Replies sent. The higher a number, the more + robust IGMP setup is. At the cost of traffic on the network. + Note: Changing this parameter doesnt take effect on a network + interface until it has (re-)enabled." + ::= { pt3080Comms 97 } + +pt3080CommsIGMPv3UnsolicitedReportInterval OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 60000 ) + UNITS "1 ms" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The time interval between unsolicited IGMPv3 reports being sent. + See RFC3376. The number of such report being sent is controlled + by the Query Robustness Count." + ::= { pt3080Comms 96 } + +pt3080CommsIGMPv2UnsolicitedReportInterval OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 60000 ) + UNITS "1 ms" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The time interval between unsolicited IGMPv2/v1 reports being + sent. See RFC2236. The number of such report being sent is + controlled by the Query Robustness Count." + ::= { pt3080Comms 95 } + +pt3080CommsAccessAllowed OBJECT-TYPE + SYNTAX INTEGER { remote(0), local-disable-set(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Current access mode allowed: Remote: SNMP via Ethernet, Local: + Frontpanel" + ::= { pt3080Comms 48 } + +pt3080CommsAccessAllowedTimeout OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 1440 ) + UNITS "1 min" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Timeout (in minutes) before local mode reverts to remote mode." + ::= { pt3080Comms 49 } + +pt3080CommsAccessAllowedTimeLeft OBJECT-TYPE + SYNTAX Integer32 + UNITS "1 secs" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current time left (in seconds) before local mode reverts to + remote mode." + ::= { pt3080Comms 50 } + + +pt3080CommsAccessPasswordObserver OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The access password for Observer level access. Will always read as empty." + ::= { pt3080Comms 51 } + +pt3080CommsAccessPasswordOperator OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The access password for Operator level access. Will always read as empty." + ::= { pt3080Comms 52 } + +pt3080CommsAccessPasswordAdministrator OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The access password for Administrator level access. Will always read as empty." + ::= { pt3080Comms 53 } + + +pt3080CommsStaticRouteTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pt3080CommsStaticRouteEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the static routing table entries" + ::= { pt3080Comms 300 } + +pt3080CommsStaticRouteEntry OBJECT-TYPE + SYNTAX Pt3080CommsStaticRouteEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the static network routing table" + INDEX { pt3080CommsStaticRouteNO } + ::= { pt3080CommsStaticRouteTable 1 } + +Pt3080CommsStaticRouteEntry ::= SEQUENCE { + pt3080CommsStaticRouteNO Integer32, + pt3080CommsStaticRouteType INTEGER, + pt3080CommsStaticRoutePrefix IpAddress, + pt3080CommsStaticRoutePrefixSize Integer32, + pt3080CommsStaticRouteTarget IpAddress, + pt3080CommsStaticRoutePhysicalInterface INTEGER +} + +pt3080CommsStaticRouteNO OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 16 ) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Unique ID for this static route entry" + ::= { pt3080CommsStaticRouteEntry 1 } + +pt3080CommsStaticRouteType OBJECT-TYPE + SYNTAX INTEGER { unused(0), normal(1), physicalif(2), recursive(3), drop(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Type of a Route table entry." + ::= { pt3080CommsStaticRouteEntry 2 } + +pt3080CommsStaticRoutePrefix OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP address part of prefix for a route table entry. + If the address is 0.0.0.0, the entry will not be used." + ::= { pt3080CommsStaticRouteEntry 3 } + +pt3080CommsStaticRoutePrefixSize OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 32 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The number of bits in the network part of the prefix for route table entry $. + If the number is 0 (zero), the entry will not be used." + ::= { pt3080CommsStaticRouteEntry 4 } + +pt3080CommsStaticRouteTarget OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The target IP address for a route table entry. + Only used if pt3080CommsStaticRouteType is normal(1) or recursive(3). + If the target address is 0.0.0.0, the entry will not be used." + ::= { pt3080CommsStaticRouteEntry 5 } + +pt3080CommsStaticRoutePhysicalInterface OBJECT-TYPE + SYNTAX INTEGER { eth0(0), eth1(1), eth2(2), eth3(3), eth4(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Physical Ethernet Interface to use for a Route table entry. + Only used when pt3080CommsStaticRouteType is physicalif(2)." + ::= { pt3080CommsStaticRouteEntry 6 } + + + + +-- +-- pt3080 Demodulator sub-tree +-- +pt3080DemodulatorFollowMode OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls the Demodulators follow mode." + ::= { pt3080Demodulator 1 } + +pt3080Demodulator1Available OBJECT-TYPE + SYNTAX INTEGER { no(0), yes(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status on the availability of Demodulator 1" + ::= { pt3080Demodulator 2 } + +pt3080Demodulator2Available OBJECT-TYPE + SYNTAX INTEGER { no(0), yes(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status on the availability of Demodulator 2" + ::= { pt3080Demodulator 29 } + +pt3080Demodulator1FWVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Demodulator 1 firmware version string" + ::= { pt3080Demodulator 3 } + +pt3080Demodulator2FWVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Demodulator 2 firmware version string" + ::= { pt3080Demodulator 30 } + +pt3080Demodulator1OutputTS OBJECT-TYPE + SYNTAX INTEGER { hp(0), lp(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls which TS demodulator 1 shall output" + ::= { pt3080Demodulator 4 } + +pt3080Demodulator2OutputTS OBJECT-TYPE + SYNTAX INTEGER { hp(0), lp(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls which TS demodulator 2 shall output" + ::= { pt3080Demodulator 31 } + +pt3080Demodulator1MerLimit OBJECT-TYPE + SYNTAX Integer32 ( 10 .. 240 ) + UNITS "0.1 dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Lower limit for MER Level" + ::= { pt3080Demodulator 5 } + +pt3080Demodulator2MerLimit OBJECT-TYPE + SYNTAX Integer32 ( 10 .. 240 ) + UNITS "0.1 dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Lower limit for MER Level" + ::= { pt3080Demodulator 32 } + +pt3080Demodulator1PreVirterbiErrorRateLimit OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 1000000 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Upper limit for Pre-Virterbi Bit Error Rate" + ::= { pt3080Demodulator 6 } + +pt3080Demodulator2PreVirterbiErrorRateLimit OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 1000000 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Upper limit for Pre-Virterbi Bit Error Rate" + ::= { pt3080Demodulator 33 } + +pt3080Demodulator1PostVirterbiErrorRateLimit OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 1000000 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Upper limit for Post-Virterbi Bit Error Rate" + ::= { pt3080Demodulator 7 } + +pt3080Demodulator2PostVirterbiErrorRateLimit OBJECT-TYPE + SYNTAX Integer32 ( 1 .. 1000000 ) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Upper limit for Post-Virterbi Bit Error Rate" + ::= { pt3080Demodulator 34 } + +pt3080Demodulator1FelStatus OBJECT-TYPE + SYNTAX INTEGER { locked(0), unlocked(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Received signal locked status on Demodulator 1" + ::= { pt3080Demodulator 8 } + +pt3080Demodulator2FelStatus OBJECT-TYPE + SYNTAX INTEGER { locked(0), unlocked(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Received signal locked status on Demodulator 2" + ::= { pt3080Demodulator 35 } + +pt3080Demodulator1UncorrectedPackets OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of uncorrected packets received in Demodulator 1 since + boot or since counter was last cleared." + ::= { pt3080Demodulator 9 } + +pt3080Demodulator2UncorrectedPackets OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of uncorrected packets received in Demodulator 2 since + boot or since counter was last cleared." + ::= { pt3080Demodulator 36 } + +pt3080Demodulator1Mer OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current MER level for Demodulator 1" + ::= { pt3080Demodulator 11 } + +pt3080Demodulator2Mer OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current MER level for Demodulator 2" + ::= { pt3080Demodulator 38 } + +pt3080Demodulator1PreVirterbiErrorRate OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 x1e-7" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current Pre-Virterbi Bit Error Rate for Demodulator 1" + ::= { pt3080Demodulator 12 } + +pt3080Demodulator2PreVirterbiErrorRate OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 x1e-7" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current Pre-Virterbi Bit Error Rate for Demodulator 2" + ::= { pt3080Demodulator 39 } + +pt3080Demodulator1PostVirterbiErrorRate OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 x1e-7" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current Post-Virterbi Bit Error Rate for Demodulator 1" + ::= { pt3080Demodulator 13 } + +pt3080Demodulator2PostVirterbiErrorRate OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 x1e-7" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current Post-Virterbi Bit Error Rate for Demodulator 2" + ::= { pt3080Demodulator 40 } + +pt3080Demodulator1ActualGuardInterval OBJECT-TYPE + SYNTAX INTEGER { g1-32(0), g1-16(1), g1-8(2), g1-4(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Guard Interval for the received signal on Demodulator 1" + ::= { pt3080Demodulator 14 } + +pt3080Demodulator2ActualGuardInterval OBJECT-TYPE + SYNTAX INTEGER { g1-32(0), g1-16(1), g1-8(2), g1-4(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Guard Interval for the received signal on Demodulator 2" + ::= { pt3080Demodulator 41 } + +pt3080Demodulator1Actualifft OBJECT-TYPE + SYNTAX INTEGER { f2k(0), f4k(1), f8k(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "IFFT for the received signal on Demodulator 1" + ::= { pt3080Demodulator 15 } + +pt3080Demodulator2Actualifft OBJECT-TYPE + SYNTAX INTEGER { f2k(0), f4k(1), f8k(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "IFFT for the received signal on Demodulator 2" + ::= { pt3080Demodulator 42 } + +pt3080Demodulator1ActualConstellation OBJECT-TYPE + SYNTAX INTEGER { qpsk(0), qam16(1), qam64(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Constellation for the received signal on Demodulator 1" + ::= { pt3080Demodulator 16 } + +pt3080Demodulator2ActualConstellation OBJECT-TYPE + SYNTAX INTEGER { qpsk(0), qam16(1), qam64(2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Constellation for the received signal on Demodulator 2" + ::= { pt3080Demodulator 43 } + +pt3080Demodulator1ActualHierarchy OBJECT-TYPE + SYNTAX INTEGER { none(0), h-1(1), h-2(2), h-4(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Hierarchy for the received signal on Demodulator 1" + ::= { pt3080Demodulator 17 } + +pt3080Demodulator2ActualHierarchy OBJECT-TYPE + SYNTAX INTEGER { none(0), h-1(1), h-2(2), h-4(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Hierarchy for the received signal on Demodulator 2" + ::= { pt3080Demodulator 44 } + +pt3080Demodulator1ActualCodeRateHighPrio OBJECT-TYPE + SYNTAX INTEGER { r1-2(0), r2-3(1), r3-4(2), r5-6(3), r7-8(4) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Priority Code Rate for the received signal on Demodulator + 1" + ::= { pt3080Demodulator 18 } + +pt3080Demodulator2ActualCodeRateHighPrio OBJECT-TYPE + SYNTAX INTEGER { r1-2(0), r2-3(1), r3-4(2), r5-6(3), r7-8(4) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Priority Code Rate for the received signal on Demodulator + 2" + ::= { pt3080Demodulator 45 } + +pt3080Demodulator1ActualCodeRateLowPrio OBJECT-TYPE + SYNTAX INTEGER { r1-2(0), r2-3(1), r3-4(2), r5-6(3), r7-8(4) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Priority Code Rate for the received signal on Demodulator + 1" + ::= { pt3080Demodulator 19 } + +pt3080Demodulator2ActualCodeRateLowPrio OBJECT-TYPE + SYNTAX INTEGER { r1-2(0), r2-3(1), r3-4(2), r5-6(3), r7-8(4) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Priority Code Rate for the received signal on Demodulator + 2" + ::= { pt3080Demodulator 46 } + +pt3080Demodulator1ActualDeepInterleaver OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Deep Interleaver for the received signal on Demodulator 1" + ::= { pt3080Demodulator 20 } + +pt3080Demodulator2ActualDeepInterleaver OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Deep Interleaver for the received signal on Demodulator 2" + ::= { pt3080Demodulator 47 } + +pt3080Demodulator1ActualMpeFecHighPrio OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Priority MPE/FEC mode for the received signal on Demodulator + 1" + ::= { pt3080Demodulator 21 } + +pt3080Demodulator2ActualMpeFecHighPrio OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Priority MPE/FEC mode for the received signal on Demodulator + 2" + ::= { pt3080Demodulator 48 } + +pt3080Demodulator1ActualMpeFecLowPrio OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low Priority MPE/FEC mode for the received signal on Demodulator + 1" + ::= { pt3080Demodulator 22 } + +pt3080Demodulator2ActualMpeFecLowPrio OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low Priority MPE/FEC mode for the received signal on Demodulator + 2" + ::= { pt3080Demodulator 49 } + +pt3080Demodulator1ActualTimeSlicingHighPrio OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Priority timeslicing mode for the received signal on Demodulator + 1" + ::= { pt3080Demodulator 23 } + +pt3080Demodulator2ActualTimeSlicingHighPrio OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High Priority timeslicing mode for the received signal on Demodulator + 2" + ::= { pt3080Demodulator 50 } + +pt3080Demodulator1ActualTimeSlicingLowPrio OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low Priority timeslicing mode for the received signal on Demodulator + 1" + ::= { pt3080Demodulator 24 } + +pt3080Demodulator2ActualTimeSlicingLowPrio OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low Priority timeslicing mode for the received signal on Demodulator + 2" + ::= { pt3080Demodulator 51 } + +pt3080Demodulator1ActualCellID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current Cell ID value for the received signal on Demodulator + 1" + ::= { pt3080Demodulator 25 } + +pt3080Demodulator2ActualCellID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current Cell ID value for the received signal on Demodulator + 1" + ::= { pt3080Demodulator 52 } + +pt3080Demodulator1ActualDVBHMode OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "DVB-H mode for the received signal on Demodulator 1" + ::= { pt3080Demodulator 26 } + +pt3080Demodulator2ActualDVBHMode OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "DVB-H mode for the received signal on Demodulator 2" + ::= { pt3080Demodulator 53 } + + + +-- +-- pt3080 Precorrector sub-tree +-- + +pt3080PrecorrectorLinearAdaptive OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Linear precorrection curve active in the system" + ::= { pt3080Precorrector 79 } + +pt3080PrecorrectorLinearMode OBJECT-TYPE + SYNTAX INTEGER { monitoring(0), static(1), adaptive(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "selection of the operational mode for the linear precorrector +
(note: legacy term used for backward compatibility. MONITORING + Equal to the mode named BYPASS in the WEB GUI )" + ::= { pt3080Precorrector 2 } + +pt3080PrecorrectorLinearSenseEnable OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "By using this, it is possible to control wether to use the linear + Sense Input or not." + ::= { pt3080Precorrector 46 } + +pt3080PrecorrectorLinearMonitorStatus OBJECT-TYPE + SYNTAX INTEGER { not-running(0), monitoring(1), initialising(2), initialising-0(3), initialising-10(4), initialising-20(5), initialising-30(6), initialising-40(7), initialising-50(8), initialising-60(9), initialising-70(10), initialising-80(11), initialising-90(12), auto-applying(13), completed(14) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "linear Precor state" + ::= { pt3080Precorrector 24 } + +pt3080PrecorrectorLinearMonitorSenseLevel OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Level meassured at the linear sense input with offset defined + by attenuation" + ::= { pt3080Precorrector 22 } + +pt3080PrecorrectorLinearMonitorSenseValid OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is linear sense input information valid" + ::= { pt3080Precorrector 23 } + +pt3080PrecorrectorLinearMonitorSenseBadCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of bad/invalid sense counts, made by the linear adaptive + precorrector." + ::= { pt3080Precorrector 8 } + +pt3080PrecorrectorLinearMonitorAmplitudeRipple OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 dB" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Amplitude ripple" + ::= { pt3080Precorrector 26 } + +pt3080PrecorrectorLinearMonitorAmplitudeRippleValid OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is amplitude ripple information valid" + ::= { pt3080Precorrector 30 } + +pt3080PrecorrectorLinearMonitorGroupDelay OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 ns" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Group delay" + ::= { pt3080Precorrector 27 } + +pt3080PrecorrectorLinearMonitorGroupDelayValid OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is group delay information valid" + ::= { pt3080Precorrector 31 } + +pt3080PrecorrectorLinearMonitorDiscartedIterations OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of iterations discarded by the linear adaptive precorrector + due to noisy signal samples." + ::= { pt3080Precorrector 47 } + +pt3080PrecorrectorLinearMonitorIterations OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of iterations made by the linear adaptive precorrector." + ::= { pt3080Precorrector 19 } + +pt3080PrecorrectorLinearAdaptiveMode OBJECT-TYPE + SYNTAX INTEGER { idle(0), autorun(1), runtotarget(2), continuous(3), single(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "selection of the operational mode for the linear adaptive precorrector +
(note: legacy term used for backward compatibility. IDLE + Equal to the mode named MONITORING in the WEB GUI )" + ::= { pt3080Precorrector 1 } + +pt3080PrecorrectorLinearAdaptiveAmplitudeRippleTargetLevel OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 10000 ) + UNITS "0.1 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define a adaptive target level for the amplitude ripple" + ::= { pt3080Precorrector 42 } + +pt3080PrecorrectorLinearAdaptiveAmplitudeRippleTargetHysteresis OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 100000 ) + UNITS "0.01 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define a adaptive target level hysteresis for the amplitude + ripple" + ::= { pt3080Precorrector 14 } + +pt3080PrecorrectorLinearAdaptiveAmplitudeRippleEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable amplitude ripple as a trigger for the AUTORUN and RUNTOTARGET + modes" + ::= { pt3080Precorrector 10 } + +pt3080PrecorrectorLinearAdaptiveGroupDelayTargetLevel OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 10000 ) + UNITS "0.1 ns" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define a adaptive target level for the group delay" + ::= { pt3080Precorrector 43 } + +pt3080PrecorrectorLinearAdaptiveGroupDelayTargetHysteresis OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 100000 ) + UNITS "0.01 ns" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define a adaptive target level hysteresis for the group delay" + ::= { pt3080Precorrector 15 } + +pt3080PrecorrectorLinearAdaptiveGroupDelayEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable group delay as a trigger for the AUTORUN and RUNTOTARGET + modes" + ::= { pt3080Precorrector 11 } + +pt3080PrecorrectorLinearAttenuation OBJECT-TYPE + SYNTAX Integer32 ( -1000 .. 1000 ) + UNITS "0.1 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define a attenuation level for the sense input" + ::= { pt3080Precorrector 78 } + +pt3080PrecorrectorNonlinearAdaptive OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Non-Linear precorrection curve active in the system" + ::= { pt3080Precorrector 80 } + +pt3080PrecorrectorNonlinearMode OBJECT-TYPE + SYNTAX INTEGER { monitoring(0), static(1), adaptive(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "selection of the operational mode for the non-linear precorrector +
(note: legacy term used for backward compatibility. MONITORING + Equal to the mode named BYPASS in the WEB GUI )" + ::= { pt3080Precorrector 4 } + +pt3080PrecorrectorNonlinearSenseEnable OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "By using this, it is possible to control wether to use the nonlinear + Sense Input or not." + ::= { pt3080Precorrector 48 } + +pt3080PrecorrectorNonlinearMonitorStatus OBJECT-TYPE + SYNTAX INTEGER { not-running(0), monitoring(1), initialising(2), initialising-0(3), initialising-10(4), initialising-20(5), initialising-30(6), initialising-40(7), initialising-50(8), initialising-60(9), initialising-70(10), initialising-80(11), initialising-90(12), auto-applying(13), completed(14) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Nonlinear Precor state" + ::= { pt3080Precorrector 40 } + +pt3080PrecorrectorNonlinearMonitorSenseLevel OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Level meassured at the Nonlinear sense input with offset defined + by attenuation" + ::= { pt3080Precorrector 38 } + +pt3080PrecorrectorNonlinearMonitorSenseValid OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is Nonlinear sense input information valid" + ::= { pt3080Precorrector 39 } + +pt3080PrecorrectorNonlinearMonitorSenseBadCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of bad/invalid sense counts, made by the nonlinear adaptive + precorrector." + ::= { pt3080Precorrector 9 } + +pt3080PrecorrectorNonlinearMonitorLowerShoulderLevel OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 dB" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Lower shoulder level" + ::= { pt3080Precorrector 28 } + +pt3080PrecorrectorNonlinearMonitorLowerShoulderValid OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is Lower shoulder information valid" + ::= { pt3080Precorrector 32 } + +pt3080PrecorrectorNonlinearMonitorUpperShoulderLevel OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 dB" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Upper shoulder level" + ::= { pt3080Precorrector 29 } + +pt3080PrecorrectorNonlinearMonitorUpperShoulderValid OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is Upper shoulder information valid" + ::= { pt3080Precorrector 33 } + +pt3080PrecorrectorNonlinearMonitorDiscartedIterations OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of iterations discarded by the non-linear adaptive precorrector + dur to noisy signal samples." + ::= { pt3080Precorrector 49 } + +pt3080PrecorrectorNonlinearMonitorIterations OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of iterations made by the nonlinear adaptive precorrector." + ::= { pt3080Precorrector 35 } + +pt3080PrecorrectorNonlinearMonitorMer OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 dB" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "MER" + ::= { pt3080Precorrector 50 } + +pt3080PrecorrectorNonlinearMonitorMerValid OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is MER information valid" + ::= { pt3080Precorrector 51 } + +pt3080PrecorrectorNonlinearMonitorPapr OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 dB" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "PAPR level" + ::= { pt3080Precorrector 52 } + +pt3080PrecorrectorNonlinearMonitorPaprValid OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is Papr information valid" + ::= { pt3080Precorrector 53 } + +pt3080PrecorrectorNonlinearAttenuation OBJECT-TYPE + SYNTAX Integer32 ( -1000 .. 1000 ) + UNITS "0.1 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define a attenuation level for the sense input" + ::= { pt3080Precorrector 77 } + +pt3080PrecorrectorNonlinearAdaptiveMode OBJECT-TYPE + SYNTAX INTEGER { idle(0), autorun(1), runtotarget(2), continuous(3), single(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "selection of the operational mode for the non-linear adaptive + precorrector
(note: legacy term used for backward compatibility. + IDLE Equal to the mode named MONITORING in the WEB GUI )" + ::= { pt3080Precorrector 3 } + +pt3080PrecorrectorNonlinearAdaptiveAveraging OBJECT-TYPE + SYNTAX INTEGER { no(0), yes(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Choose wether or not to use averaging calulations" + ::= { pt3080Precorrector 54 } + +pt3080PrecorrectorNonlinearAdaptiveMaxRfPaprEnable OBJECT-TYPE + SYNTAX INTEGER { disable(0), enable(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable the modulator's output PAPR limiter function" + ::= { pt3080Precorrector 55 } + +pt3080PrecorrectorNonlinearAdaptiveMaxRfPaprLimit OBJECT-TYPE + SYNTAX Integer32 ( 20 .. 180 ) + UNITS "0.1 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Maximum RF PAPR Limitation" + ::= { pt3080Precorrector 56 } + +pt3080PrecorrectorNonlinearAdaptiveMerTarget OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 800 ) + UNITS "0.1 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define a target level for the MER" + ::= { pt3080Precorrector 57 } + +pt3080PrecorrectorNonlinearAdaptiveMerTargetHysteresis OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 1000 ) + UNITS "0.01 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define a target MER hysteresis" + ::= { pt3080Precorrector 58 } + +pt3080PrecorrectorNonlinearAdaptiveMerEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable MER as a trigger for the AUTORUN and RUNTOTARGET modes" + ::= { pt3080Precorrector 59 } + +pt3080PrecorrectorNonlinearAdaptiveLowerShoulderTargetLevel OBJECT-TYPE + SYNTAX Integer32 ( -800 .. 0 ) + UNITS "0.1 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define a adaptive target level for the lower shoulder" + ::= { pt3080Precorrector 44 } + +pt3080PrecorrectorNonlinearAdaptiveLowerShoulderTargetHysteresis OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 1000 ) + UNITS "0.01 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define a adaptive target level hysteresis for the lower shoulder" + ::= { pt3080Precorrector 16 } + +pt3080PrecorrectorNonlinearAdaptiveLowerShoulderEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable shoulder level (lower) as a trigger for the AUTORUN and + RUNTOTARGET modes" + ::= { pt3080Precorrector 12 } + +pt3080PrecorrectorNonlinearAdaptiveUpperShoulderTargetLevel OBJECT-TYPE + SYNTAX Integer32 ( -800 .. 0 ) + UNITS "0.1 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define a adaptive target level for the upper shoulder" + ::= { pt3080Precorrector 45 } + +pt3080PrecorrectorNonlinearAdaptiveUpperShoulderTargetHysteresis OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 1000 ) + UNITS "0.01 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Define a adaptive target level hysteresis for the upper shoulder" + ::= { pt3080Precorrector 17 } + +pt3080PrecorrectorNonlinearAdaptiveUpperShoulderEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable shoulder level (upper) as a trigger for the AUTORUN and + RUNTOTARGET modes" + ::= { pt3080Precorrector 13 } + +pt3080PrecorrectorPaprClipping OBJECT-TYPE + SYNTAX Integer32 ( 200 .. 1200 ) + UNITS "0.01 dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "set the built-in peak clipper function. The value 'max' corresponds + to an unclipped COFDM signal (12dB peak to average ratio). + The value 'min' correspondsto COFDM signal where all peaks >2dB + above average power are clipped. When feeding the output from + the modulator through an amplifier the best overall performance + result is normally obtained if the clipper value used by modulator + clips the signal just a fraction before the amplifier would + clip the signal." + ::= { pt3080Precorrector 60 } + +pt3080PrecorrectorPaprShaping OBJECT-TYPE + SYNTAX Integer32 ( 0 .. 100 ) + UNITS "1 %" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Set the output peak shaping filter hardness. The value 'min' + correspond to traditional 'hard-clipping' where the clipper + noise is equally distributed below, inside and above the COFDM + spectrum (clipper noise clearly visible in the form of noise + above and below the spectrum. The value 'max' corresponds to + maximum soft clipping where the clipper noise in the sidebands + (above and below the COFDM spectrum) is subjected to maximum + suppression while still maintaining the exact clipper value + (peak-to-average-ration). The suppression of the sideband noise + is obtained as a tradeoff against the in band performance. + The clip filter setting is typically selected as a compromise + between spectrum shoulder performance and in-band signal performance + (MER)." + ::= { pt3080Precorrector 61 } + +pt3080PrecorrectorClipperMode OBJECT-TYPE + SYNTAX INTEGER { monitoring(0), static(1), adaptive(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selection between no, static (manual) and adaptive clipper function" + ::= { pt3080Precorrector 74 } + +pt3080PrecorrectorClipperAdaptive OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Clipper shaped by the OptiClipper algorithm" + ::= { pt3080Precorrector 75 } + +pt3080PrecorrectorClipperEnable OBJECT-TYPE + SYNTAX INTEGER { off(0), on(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Clipper enable" + ::= { pt3080Precorrector 76 } + +pt3080PrecorrectorClipperAdaptiveMode OBJECT-TYPE + SYNTAX INTEGER { monitoring(0), continuous(1), single(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selection of the operational mode for the adaptive clipper function" + ::= { pt3080Precorrector 63 } + +pt3080PrecorrectorClipperAdaptiveShaping OBJECT-TYPE + SYNTAX Integer32 ( 99 .. 100 ) + UNITS "1 %" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Depricated Therefore min and max value are set to 100% Set the + peak shaping filter hardness. The value 'min' correspond to + traditional 'hard-clipping' where the clipper noise is equally + distributed below, inside and above the COFDM spectrum (clipper + noise clearly visible in the form of noise above and below + the spectrum. The value 'max' corresponds to maximum soft clipping + where the clipper noise in the sidebands (above and below the + COFDM spectrum) is subjected to maximum suppression while still + maintaining the exact clipper value (peak-to-average-ration). + The suppression of the sideband noise is obtained as a tradeoff + against the in band performance. The clip filter setting is + typically selected as a compromise between spectrum shoulder + performance and in-band signal performance (MER)." + ::= { pt3080Precorrector 81 } + +pt3080PrecorrectorClipperMonitorStatus OBJECT-TYPE + SYNTAX INTEGER { not-running(0), monitoring(1), initialising(2), initialising-0(3), initialising-10(4), initialising-20(5), initialising-30(6), initialising-40(7), initialising-50(8), initialising-60(9), initialising-70(10), initialising-80(11), initialising-90(12), auto-applying(13), completed(14) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "OptiClipper state" + ::= { pt3080Precorrector 64 } + +pt3080PrecorrectorClipperMonitorShoulderLevelLower OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 dB" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Lower shoulder level" + ::= { pt3080Precorrector 65 } + +pt3080PrecorrectorClipperMonitorShoulderLevelLowerValid OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is Lower shoulder information valid" + ::= { pt3080Precorrector 66 } + +pt3080PrecorrectorClipperMonitorShoulderLevelUpper OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 dB" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Upper shoulder level" + ::= { pt3080Precorrector 67 } + +pt3080PrecorrectorClipperMonitorShoulderLevelUpperValid OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is Upper shoulder information valid" + ::= { pt3080Precorrector 68 } + +pt3080PrecorrectorClipperMonitorMer OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 dB" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "MER level" + ::= { pt3080Precorrector 69 } + +pt3080PrecorrectorClipperMonitorMerValid OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is MER information valid" + ::= { pt3080Precorrector 70 } + +pt3080PrecorrectorClipperMonitorPapr OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 dB" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "PAPR level" + ::= { pt3080Precorrector 71 } + +pt3080PrecorrectorClipperMonitorPaprValid OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is Papr information valid" + ::= { pt3080Precorrector 72 } + +pt3080PrecorrectorClipperMonitorIterations OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of Iterations performed by the OptiClipper algorithm" + ::= { pt3080Precorrector 73 } + + +pt3080PrecorrectorLastTurnAroundTime OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "PrecorrectorLastTurnAroundTime " + ::= { pt3080Precorrector 6 } + +pt3080PrecorrectorSecondsSinceLastUpdate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "PrecorrectorSecondsSinceLastUpdate " + ::= { pt3080Precorrector 7 } + +pt3080PrecorrectorLinCleanrun OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "PrecorrectorLinCleanrun " + ::= { pt3080Precorrector 18 } + +pt3080PrecorrectorNlinCleanrun OBJECT-TYPE + SYNTAX INTEGER { no(0), yes(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "PrecorrectorNlinCleanrun " + ::= { pt3080Precorrector 34 } + +pt3080PrecorrectorLinearLoadNeutral OBJECT-TYPE + SYNTAX INTEGER { noop(0), load(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "PrecorrectorLinearLoadNeutral " + ::= { pt3080Precorrector 20 } + +pt3080PrecorrectorLinearLoadFactory OBJECT-TYPE + SYNTAX INTEGER { noop(0), load(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "PrecorrectorLinearLoadFactory " + ::= { pt3080Precorrector 21 } + +pt3080PrecorrectorLinearUpdateFactoryCurve OBJECT-TYPE + SYNTAX INTEGER { noop(0), update(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "PrecorrectorLinearUpdateFactoryCurve " + ::= { pt3080Precorrector 25 } + +pt3080PrecorrectorNonlinearLoadNeutral OBJECT-TYPE + SYNTAX INTEGER { noop(0), load(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "PrecorrectorNonlinearLoadNeutral " + ::= { pt3080Precorrector 36 } + +pt3080PrecorrectorNonlinearLoadFactory OBJECT-TYPE + SYNTAX INTEGER { noop(0), load(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "PrecorrectorNonlinearLoadFactory " + ::= { pt3080Precorrector 37 } + +pt3080PrecorrectorNonlinearUpdateFactoryCurve OBJECT-TYPE + SYNTAX INTEGER { noop(0), update(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "PrecorrectorNonlinearUpdateFactoryCurve " + ::= { pt3080Precorrector 41 } + +-- +-- pt3080 Backplane sub-tree +-- + +pt3080BackplanePolarityHardMute OBJECT-TYPE + SYNTAX INTEGER { activelow(0), activehigh(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Set the polarity of the Hard Mute input pin on the PTT2 backplane." + ::= { pt3080Backplane 1 } + +pt3080BackplanePolarityRFFail OBJECT-TYPE + SYNTAX INTEGER { activelow(0), activehigh(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Set the polarity of the RF Fail output pin on the PTT2 backplane." + ::= { pt3080Backplane 2 } + + +-- +-- pt3080 Notifications sub-tree +-- + +pt3080Notif OBJECT IDENTIFIER ::= { pt3080Notifs 0 } + +pt3080NotifMessage OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The current alarm notification message" + ::= { pt3080Notifs 1 } + +pt3080NotifState OBJECT-TYPE + SYNTAX INTEGER { off(0), activated(1) } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The current alarm notification state" + ::= { pt3080Notifs 2 } + + +pt3080NotifLocalTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The time the current alarm notification state changed" + ::= { pt3080Notifs 3 } + + +-- SNMPv2 compliance nonsense -- +pt3080Compliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for systems supporting + the this MIB." + MODULE -- this module + MANDATORY-GROUPS { + pt3080SystemGroup, pt3080InputGroup, pt3080OutputGroup, + pt3080MonitorGroup, + pt3080TestGroup, pt3080AlarmGroup, pt3080PresetGroup, + pt3080EventlogGroup, pt3080CommsGroup, pt3080PrecorrectorGroup + } + GROUP pt3080ModeGroup + DESCRIPTION + "This group is optional." + GROUP pt3080GpsGroup + DESCRIPTION + "This group is optional." + GROUP pt3080ChannelFilterGroup + DESCRIPTION + "This group is optional." + GROUP pt3080TSoIPGroup + DESCRIPTION + "This group is optional." + GROUP pt3080DemodulatorGroup + DESCRIPTION + "This group is optional." + GROUP pt3080ReceptionGroup + DESCRIPTION + "This group is optional." + GROUP pt3080ASIGroup + DESCRIPTION + "This group is optional." + ::= { pt3080Compliances 1 } + + pt3080Groups OBJECT IDENTIFIER ::= { pt3080Conformance 2 } + + pt3080SystemGroup OBJECT-GROUP + OBJECTS { + pt3080SystemInstrumentFW1Rev, + pt3080SystemInstrumentFW1RevBL, + pt3080SystemInstrumentFW2Rev, + pt3080SystemInstrumentFW2RevBL, + pt3080SystemInstrumentFW3Rev, + pt3080SystemInstrumentFW4Rev, + pt3080SystemInstrumentPCBRev, + pt3080SystemInstrumentCalibrationRev, + pt3080SystemInstrumentCalibrationDate, + pt3080SystemReboot, + pt3080SystemRebootDefaultConfig, + pt3080SystemDateTime, + pt3080SystemImage0Version, + pt3080SystemImage0InstalledDate, + pt3080SystemImage1version, + pt3080SystemImage1InstalledDate, + pt3080SystemScheduledActionRecurrence, + pt3080SystemScheduledActionHour, + pt3080SystemScheduledActionMinute, + pt3080SystemScheduledActionWeekday, + pt3080SystemScheduledActionMonthDay, + pt3080SystemScheduledActionDate, + pt3080SystemScheduledActionRandomDelay, + pt3080SystemScheduledActionAction, + pt3080SystemScheduledActionRepeaterMode, + pt3080SystemScheduledActionPresetNo, + pt3080SystemScheduledActionRebootImage, + pt3080SystemScheduledActionRebootSystemType, + pt3080SystemScheduledActionMute, + pt3080SystemScheduledActionSWUpgradeProtocol, + pt3080SystemScheduledActionSWUpgradeUsername, + pt3080SystemScheduledActionSWUpgradePassword, + pt3080SystemScheduledActionSWUpgradeImageServer, + pt3080SystemScheduledActionSWUpgradeImagePath, + pt3080SystemServiceLED +, + pt3080SystemLanguage +, + pt3080SystemType, + pt3080SystemModulationStandard, + pt3080SystemCurrentImage, + pt3080SystemInstrumentKU, + pt3080SystemInstrumentType, + pt3080SystemInstrumentOptions, + pt3080SystemDateTimeSync, + pt3080SystemDateTimeSyncActual, + pt3080SystemTimezone, + pt3080SystemInstrumentSWRev, + pt3080SystemInstrumentBootLoaderRev, + pt3080SystemInstrumentKernelRev, + pt3080SystemOperationOnTime, + pt3080SystemOperationOnAirTime, + pt3080SystemOperationNumberOfBoots, + pt3080SystemBackplaneid, + pt3080SystemBackplaneIdRaw, + pt3080SystemBackplaneIdPcb, + pt3080SystemBackplaneIdCableOptions, + pt3080SystemBackplaneIdMAnuf, + pt3080SystemBackplaneCalibrationDate, + pt3080SystemBackplaneCalibrationSw, + pt3080SystemBackplaneIdPartlist + } + STATUS current + DESCRIPTION + "System group" + ::= { pt3080Groups 1} + + pt3080ModeGroup OBJECT-GROUP + OBJECTS { + pt3080ModeListenBroadcast + , + pt3080ModeNetwork, + pt3080ModeHierarchy, + pt3080Modeifft, + pt3080ModeCodeRateHighPrio, + pt3080ModeCodeRateLowPrio, + pt3080ModeConstellation, + pt3080ModeGuardInterval, + pt3080ModeCellID, + pt3080ModeEnableCellID, + pt3080ModeDeepInterleaver, + pt3080ModeEnableDVBH, + pt3080ModeMpeFecLowPrio, + pt3080ModeMpeFecHighPrio, + pt3080ModeTimeSlicingLowPrio, + pt3080ModeTimeSlicingHighPrio, + pt3080ModeSfnDelayOffset, + pt3080ModeTxIdent, + pt3080ModeMipControl, + pt3080ModeNetworkDelayHP, + pt3080ModeNetworkDelayMinHP, + pt3080ModeNetworkDelayMaxHP, + pt3080ModeMaxNetworkDelayHP, + pt3080ModeNetworkDelayMarginHP, + pt3080ModeNetworkDelayLP, + pt3080ModeNetworkDelayMinLP, + pt3080ModeNetworkDelayMaxLP, + pt3080ModeMaxNetworkDelayLP, + pt3080ModeNetworkDelayMarginLP, + pt3080ModeNetworkDelayReset, + pt3080ModeDefaultMIPOutputPower, + pt3080ModeDefaultMIPOutputTimeOffset, + pt3080ModeDefaultMIPOutputCellID, + pt3080ModeDefaultMIPOutputFreqOffset, + pt3080ModeMIPMaxSFNDelay, + pt3080ModeMipControlOutputPower, + pt3080ModeMipControlOutputTimeOffset, + pt3080ModeMipControlOutputCellId, + pt3080ModeMipControlOutputFreqOffset, + pt3080ModeMfnKeepNullPackets + } + STATUS current + DESCRIPTION + "DVB-T Mode group" + ::= { pt3080Groups 2} + + pt3080InputGroup OBJECT-GROUP + OBJECTS { + pt3080InputASITSPrimarySource, + pt3080InputASITSSecondarySource, + pt3080InputASIAutoRoutingPolicy, + pt3080InputTSPrimaryMaxPATDelay, + pt3080InputTSPrimaryMaxPATDelayEnable, + pt3080InputTSPrimaryExpectedTSID, + pt3080InputTSPrimaryExpectedTSIDEnable, + pt3080InputTSPrimaryExpectedNWID, + pt3080InputTSPrimaryExpectedNWIDEnable, + pt3080InputTSPrimaryMaxStuffingrate, + pt3080InputTSPrimaryMaxStuffingrateEnable, + pt3080InputTSPrimaryMinDelaymargin, + pt3080InputTSPrimaryMinDelaymarginEnable, + pt3080InputTSPrimaryMaxMissingmip, + pt3080InputTSPrimaryMaxMissingmipEnable, + pt3080InputTSSecondaryMaxPATDelay, + pt3080InputTSSecondaryMaxPATDelayEnable, + pt3080InputTSSecondaryExpectedTSID, + pt3080InputTSSecondaryExpectedTSIDEnable, + pt3080InputTSSecondaryExpectedNWID, + pt3080InputTSSecondaryExpectedNWIDEnable, + pt3080InputTSSecondaryMaxStuffingrate, + pt3080InputTSSecondaryMaxStuffingrateEnable, + pt3080InputTSSecondaryMinDelaymargin, + pt3080InputTSSecondaryMinDelaymarginEnable, + pt3080InputTSSecondaryMaxMissingmip, + pt3080InputTSSecondaryMaxMissingmipEnable +, + pt3080InputTSPrimaryMaxStsJitter, + pt3080InputTSSecondaryMaxStsJitter, + pt3080InputTSPrimaryStatus, + pt3080InputTSSecondaryStatus, + pt3080InputTSHp, + pt3080InputTSLp, + pt3080InputEffectiveAutoroutingPolicy, + pt3080InputTSHpBitrate, + pt3080InputTSLpBitrate, + pt3080InputTSHpPacketsBuffered, + pt3080InputTSHpPacketSize, + pt3080InputTSHpStuffingrate, + pt3080InputTSHpTSID, + pt3080InputTSLpPacketsBuffered, + pt3080InputTSLpPacketSize, + pt3080InputTSLpStuffingrate, + pt3080InputTSLpTSID, + + pt3080InputTSHpNWID, + pt3080InputTSLpNWID, + pt3080InputTSPrimaryStsJitter, + pt3080InputTSPrimaryStsJitterMax, + pt3080InputTSPrimaryStsJitterMin, + pt3080InputTSPrimaryStsJitterReset, + pt3080InputTSSecondaryStsJitter, + pt3080InputTSSecondaryStsJitterMax, + pt3080InputTSSecondaryStsJitterMin, + pt3080InputTSSecondaryStsJitterReset, + pt3080InputRefDevType, + pt3080InputRefCalDate, + pt3080InputRefCalVer +, + pt3080InputRefDirection + +, + pt3080InputRefSource, + pt3080InputRefStatus, + pt3080InputRef10MhzImpedance, + pt3080InputRef10MhzHoldoverDelay, + pt3080InputRef10MhzHoldoverForever, + pt3080InputRef1PPSImpedance, + pt3080InputRef1PPSHoldoverDelay, + pt3080InputRef1PPSHoldoverForever, + pt3080InputRef1PPSTrigSlope, + pt3080InputRef1PPSTrigLevel, + pt3080InputASIAutoRoutingDelayHp2Lp, + pt3080InputASIAutoRoutingDelayLp2Hp, + pt3080InputASIHoldoverTimeout + } + STATUS current + DESCRIPTION + "Input group" + ::= { pt3080Groups 3} + + pt3080OutputGroup OBJECT-GROUP + OBJECTS { + pt3080OutputIfEnable, + pt3080OutputIfFrequency, + pt3080OutputIfPolarity, + pt3080OutputIfLevel, + pt3080OutputMode, + pt3080OutputEffectiveLevel, + pt3080OutputActualLevel, + pt3080OutputPolarity, + pt3080OutputRfFrequency, + pt3080OutputRfFrequencyOffset, + pt3080OutputRfLevel, + pt3080OutputRfCableMode, + pt3080OutputRfCableConstantLevelOffset, + pt3080OutputRfCableFrequencyLevelOffset0, + pt3080OutputRfCableFrequencyLevelOffset1, + pt3080OutputRfCableFrequencyLevelOffset2, + pt3080OutputRfCableFrequencyLevelOffset3, + pt3080OutputRfCableFrequencyLevelOffset4, + pt3080OutputRfCableFrequencyLevelOffset5, + pt3080OutputRfDetectedActualLevel, + pt3080OutputRfDetectedLowerLevelLimit, + pt3080OutputRfDetectedLowerLevelcontrol, + pt3080OutputRfDetectedHigherLevelLimit, + pt3080OutputRfDetectedHigherLevelcontrol, + pt3080OutputRfAlcControl, + pt3080OutputRfAlcSense, + pt3080OutputRfAlcSetpointPort1, + pt3080OutputRfAlcSetpointPort2, + pt3080OutputRfAlcStatus, + pt3080OutputRfAlcStatusInformation + ,pt3080OutputBandwidth, + pt3080OutputChannel, + pt3080OutputSynchronized, + pt3080OutputMute, + pt3080OutputPowerLevel + } + STATUS current + DESCRIPTION + "Output group" + ::= { pt3080Groups 4} + + pt3080GpsGroup OBJECT-GROUP + OBJECTS { + pt3080GpsBias, + pt3080GpsbiasVoltage +, + pt3080GpsCableDelay +, + pt3080GpsHoldoverForever, + pt3080GpsHoldoverTime, + pt3080GpsSatelliteSystemGPS, + pt3080GpsSatelliteSystemGLONASS, + pt3080GpsSatelliteSystemGALILEO, + pt3080GpsSatelliteSystemCOMPASS, + pt3080GpsVersion, + pt3080Gps1PPSStatus, + pt3080GpsState, + pt3080GpsVisibleSatellitesSnr, + pt3080GpsVisibleSatellites, + pt3080GpsTrackedSatellites, + pt3080GpsLongtitude, + pt3080GpsLatitude, + pt3080GpsAltitude + } + STATUS current + DESCRIPTION + "GPS group" + ::= { pt3080Groups 7} + + pt3080ChannelFilterGroup OBJECT-GROUP + OBJECTS { + pt3080ChannelFiltersSelect + } + STATUS current + DESCRIPTION + "Channel Filter group" + ::= { pt3080Groups 8} + + + + pt3080TSoIPGroup OBJECT-GROUP + OBJECTS { + pt3080TSoIPRx1ReceiverEnable, + pt3080TSoIPRx2ReceiverEnable, + pt3080TSoIPRx1LanSelect, + pt3080TSoIPRx2LanSelect, + pt3080TSoIPRx1Multicast, + pt3080TSoIPRx2Multicast, + pt3080TSoIPRx1Protocol, + pt3080TSoIPRx2Protocol, + pt3080TSoIPRx1Portnumber, + pt3080TSoIPRx2Portnumber, + pt3080TSoIPRx1PacketErrorRatioLimit, + pt3080TSoIPRx2PacketErrorRatioLimit, + pt3080TSoIPRx1MinumimLatency, + pt3080TSoIPRx2MinumimLatency, + pt3080TSoIPRx1SyncTimeout, + pt3080TSoIPRx2SyncTimeout, + pt3080TSoIPRx1Status, + pt3080TSoIPRx2Status, + pt3080TSoIPRx1CurrentIPAddress, + pt3080TSoIPRx2CurrentIPAddress, + pt3080TSoIPRx1IpBitrate, + pt3080TSoIPRx2IpBitrate, + pt3080TSoIPRx1PacketErrorRatio, + pt3080TSoIPRx2PacketErrorRatio, + pt3080TSoIPRx1SequenceErrors, + pt3080TSoIPRx2SequenceErrors, + pt3080TSoIPRx1LostIPFrames, + pt3080TSoIPRx2LostIPFrames, + pt3080TSoIPRx1CorrectedIPFrames, + pt3080TSoIPRx2CorrectedIPFrames, + pt3080TSoIPRx1OverrunIPFrames, + pt3080TSoIPRx2OverrunIPFrames, + pt3080TSoIPRx1PacketsPerFrame, + pt3080TSoIPRx2PacketsPerFrame, + pt3080TSoIPRx1TSPacketSize, + pt3080TSoIPRx2TSPacketSize, + pt3080TSoIPRx1FecColumn, + pt3080TSoIPRx2FecColumn, + pt3080TSoIPRx1FecRow, + pt3080TSoIPRx2FecRow, + pt3080TSoIPRx1QueueSize, + pt3080TSoIPRx2QueueSize, + pt3080TSoIPRx1CurrentLatency, + pt3080TSoIPRx2CurrentLatency + } + STATUS current + DESCRIPTION + "TSoIP group" + ::= { pt3080Groups 10} + + pt3080MonitorGroup OBJECT-GROUP + OBJECTS { + pt3080MonitorSource, + pt3080MonitorTSoIPEnable, + pt3080MonitorTSoIPSource, + pt3080MonitorTSoIPMulticastLanSelect, + pt3080MonitorTSoIPDestIPAddress, + pt3080MonitorTSoIPDestPort, + pt3080MonitorTSoIPProtocol, + pt3080MonitorTSoIPEnableFec, + pt3080MonitorTSoIPFecColumn, + pt3080MonitorTSoIPFecRow, + pt3080MonitorTSoIPFecSkew, + pt3080MonitorTSoIPKeepNullPackets, + pt3080MonitorTSoIPPacketsPerFrame, + pt3080MonitorTSoIPUDPChecksum, + pt3080MonitorTSoIPDSCP, + pt3080MonitorTSoIPTTL, + pt3080MonitorTSoIPGenerateError, + pt3080MonitorTSoIPIpBitrate, + pt3080MonitorTSoIPTSSize, + pt3080MonitorTSoIPLostIPFrames + } + STATUS current + DESCRIPTION + "Signal monitor group" + ::= { pt3080Groups 12} + + pt3080TestGroup OBJECT-GROUP + OBJECTS { + pt3080TestEnable, + pt3080TestEnableReconnect, + pt3080TestScarrierLevel, + pt3080TestscarrierFrequencyOffset + } + STATUS current + DESCRIPTION + "Test Signal group" + ::= { pt3080Groups 13} + + pt3080AlarmGroup OBJECT-GROUP + OBJECTS { + pt3080GroupAlarmDescription, + pt3080GroupAlarmState, + pt3080GroupAlarmActionEventlog, + pt3080GroupAlarmActionRelay1, + pt3080GroupAlarmActionRelay2, + pt3080GroupAlarmActionTrap, + pt3080GroupAlarmActionEmail, + pt3080GroupAlarmActionAlarmLED, + pt3080GroupAlarmActionForceMode, + pt3080ASITSPrimaryAlarmDescription, + pt3080ASITSPrimaryAlarmState, + pt3080ASITSPrimaryAlarmActionEventlog, + pt3080ASITSPrimaryAlarmActionRelay1, + pt3080ASITSPrimaryAlarmActionRelay2, + pt3080ASITSPrimaryAlarmActionTrap, + pt3080ASITSPrimaryAlarmActionEmail, + pt3080ASITSPrimaryAlarmActionAlarmLED, + pt3080ASITSPrimaryAlarmActionForceMode, + pt3080ASITSSecondaryAlarmDescription, + pt3080ASITSSecondaryAlarmState, + pt3080ASITSSecondaryAlarmActionEventlog, + pt3080ASITSSecondaryAlarmActionRelay1, + pt3080ASITSSecondaryAlarmActionRelay2, + pt3080ASITSSecondaryAlarmActionTrap, + pt3080ASITSSecondaryAlarmActionEmail, + pt3080ASITSSecondaryAlarmActionAlarmLED, + pt3080ASITSSecondaryAlarmActionForceMode, + pt3080SFNAlarmDescription, + pt3080SFNAlarmState, + pt3080SFNAlarmActionEventlog, + pt3080SFNAlarmActionRelay1, + pt3080SFNAlarmActionRelay2, + pt3080SFNAlarmActionTrap, + pt3080SFNAlarmActionEmail, + pt3080SFNAlarmActionAlarmLED, + pt3080SFNAlarmActionForceMode, + pt3080TSoIPAlarmDescription, + pt3080TSoIPAlarmState, + pt3080TSoIPAlarmActionEventlog, + pt3080TSoIPAlarmActionRelay1, + pt3080TSoIPAlarmActionRelay2, + pt3080TSoIPAlarmActionTrap, + pt3080TSoIPAlarmActionEmail, + pt3080TSoIPAlarmActionAlarmLED, + pt3080TSoIPAlarmActionForceMode, + pt3080DemodulatorAlarmDescription, + pt3080DemodulatorAlarmState, + pt3080DemodulatorAlarmActionEventlog, + pt3080DemodulatorAlarmActionRelay1, + pt3080DemodulatorAlarmActionRelay2, + pt3080DemodulatorAlarmActionTrap, + pt3080DemodulatorAlarmActionEmail, + pt3080DemodulatorAlarmActionAlarmLED, + pt3080DemodulatorAlarmActionForceMode, + pt3080ReferenceAlarmDescription, + pt3080ReferenceAlarmState, + pt3080ReferenceAlarmActionEventlog, + pt3080ReferenceAlarmActionRelay1, + pt3080ReferenceAlarmActionRelay2, + pt3080ReferenceAlarmActionTrap, + pt3080ReferenceAlarmActionEmail, + pt3080ReferenceAlarmActionAlarmLED, + pt3080ReferenceAlarmActionForceMode, + pt3080RFAlarmDescription, + pt3080RFAlarmState, + pt3080RFAlarmActionEventlog, + pt3080RFAlarmActionRelay1, + pt3080RFAlarmActionRelay2, + pt3080RFAlarmActionTrap, + pt3080RFAlarmActionEmail, + pt3080RFAlarmActionAlarmLED, + pt3080RFAlarmActionForceMode, + pt3080GPSAlarmDescription, + pt3080GPSAlarmState, + pt3080GPSAlarmActionEventlog, + pt3080GPSAlarmActionRelay1, + pt3080GPSAlarmActionRelay2, + pt3080GPSAlarmActionTrap, + pt3080GPSAlarmActionEmail, + pt3080GPSAlarmActionAlarmLED, + pt3080GPSAlarmActionForceMode, + pt3080ExternalAlarmDescription, + pt3080ExternalAlarmState, + pt3080ExternalAlarmActionEventlog, + pt3080ExternalAlarmActionRelay1, + pt3080ExternalAlarmActionRelay2, + pt3080ExternalAlarmActionTrap, + pt3080ExternalAlarmActionEmail, + pt3080ExternalAlarmActionAlarmLED, + pt3080ExternalAlarmActionForceMode, + pt3080HWMonitorAlarmDescription, + pt3080HWMonitorAlarmState, + pt3080HWMonitorAlarmActionEventlog, + pt3080HWMonitorAlarmActionRelay1, + pt3080HWMonitorAlarmActionRelay2, + pt3080HWMonitorAlarmActionTrap, + pt3080HWMonitorAlarmActionEmail, + pt3080HWMonitorAlarmActionAlarmLED, + pt3080HWMonitorAlarmActionForceMode, + pt3080CommsAlarmDescription, + pt3080CommsAlarmState, + pt3080CommsAlarmActionEventlog, + pt3080CommsAlarmActionRelay1, + pt3080CommsAlarmActionRelay2, + pt3080CommsAlarmActionTrap, + pt3080CommsAlarmActionEmail, + pt3080CommsAlarmActionAlarmLED, + pt3080CommsAlarmActionForceMode, + pt3080InternalAlarmDescription, + pt3080InternalAlarmState, + pt3080InternalAlarmActionEventlog, + pt3080InternalAlarmActionRelay1, + pt3080InternalAlarmActionRelay2, + pt3080InternalAlarmActionTrap, + pt3080InternalAlarmActionEmail, + pt3080InternalAlarmActionAlarmLED, + pt3080InternalAlarmActionForceMode, + pt3080ASIAlarmDescription, + pt3080ASIAlarmState, + pt3080ASIAlarmActionEventlog, + pt3080ASIAlarmActionRelay1, + pt3080ASIAlarmActionRelay2, + pt3080ASIAlarmActionTrap, + pt3080ASIAlarmActionEmail, + pt3080ASIAlarmActionAlarmLED, + pt3080ASIAlarmActionForceMode + } + STATUS current + DESCRIPTION + "Alarm group" + ::= { pt3080Groups 14} + + pt3080PresetGroup OBJECT-GROUP + OBJECTS { + pt3080PresetName, + pt3080PresetRecall, + pt3080PresetStore + } + STATUS current + DESCRIPTION + "Preset group" + ::= { pt3080Groups 15} + + pt3080EventlogGroup OBJECT-GROUP + OBJECTS { + pt3080EventlogID, + pt3080EventlogTimestamp, + pt3080EventlogText, + pt3080EventlogClear, + pt3080EventlogEnable, + pt3080EventlogMode + } + STATUS current + DESCRIPTION + "Eventlog group" + ::= { pt3080Groups 16} + + pt3080CommsGroup OBJECT-GROUP + OBJECTS { + pt3080CommsAccessPasswordObserver, + pt3080CommsAccessPasswordOperator, + pt3080CommsAccessPasswordAdministrator, + pt3080CommsStaticRouteType, + pt3080CommsStaticRoutePrefix, + pt3080CommsStaticRoutePrefixSize, + pt3080CommsStaticRouteTarget, + pt3080CommsStaticRoutePhysicalInterface, + pt3080CommsAlarmEmailReceiver, + pt3080CommsSeparatedSwitchPorts, + pt3080CommsBroadcastStormProtection, + pt3080CommsLocalPhysicalInterface, + pt3080CommsLocalDhcpMode, + pt3080CommsLocalStaticIpAddr, + pt3080CommsLocalStaticNetmask, + pt3080CommsLocalIpMulticastAddr, + pt3080CommsLocalIpMulticastSourceFilterMode, + pt3080CommsLocalIpMulticastSourceFilterAddress1, + pt3080CommsLocalIpMulticastSourceFilterAddress2, + pt3080CommsLocalIpMulticastSourceFilterAddress3, + pt3080CommsLocalIpMulticastSourceFilterAddress4, + pt3080CommsLocalIpMulticastSourceFilterAddress5, + pt3080CommsLocalIpMulticastSourceFilterAddress6, + pt3080CommsLocalVlanEnable, + pt3080CommsLocalVlanId, + pt3080CommsLocalServiceSNMP, + pt3080CommsLocalServiceSCPI, + pt3080CommsLocalServiceTSoIP, + pt3080CommsLocalServiceRIP, + pt3080CommsLocalCurrentIpAddr, + pt3080CommsLocalCurrentNetmask, + pt3080CommsRemoteEnable, + pt3080CommsRemotePhysicalInterface, + pt3080CommsRemoteDhcpMode, + pt3080CommsRemoteStaticIpAddr, + pt3080CommsRemoteStaticNetmask, + pt3080CommsRemoteIpMulticastAddr, + pt3080CommsRemoteIpMulticastSourceFilterMode, + pt3080CommsRemoteIpMulticastSourceFilterAddress1, + pt3080CommsRemoteIpMulticastSourceFilterAddress2, + pt3080CommsRemoteIpMulticastSourceFilterAddress3, + pt3080CommsRemoteIpMulticastSourceFilterAddress4, + pt3080CommsRemoteIpMulticastSourceFilterAddress5, + pt3080CommsRemoteIpMulticastSourceFilterAddress6, + pt3080CommsRemoteVlanEnable, + pt3080CommsRemoteVlanId, + pt3080CommsRemoteServiceSNMP, + pt3080CommsRemoteServiceSCPI, + pt3080CommsRemoteServiceTSoIP, + pt3080CommsRemoteServiceWeb, + pt3080CommsRemoteServiceRIP, + pt3080CommsRemoteCurrentIpAddr, + pt3080CommsRemoteCurrentNetmask, + pt3080CommsGbeAdminEnable, + pt3080CommsGbeAdminPhysicalInterface, + pt3080CommsGbeAdminDhcpMode, + pt3080CommsGbeAdminStaticIpAddr, + pt3080CommsGbeAdminStaticNetmask, + pt3080CommsGbeAdminIpMulticastAddr, + pt3080CommsGbeAdminIpMulticastSourceFilterMode, + pt3080CommsGbeAdminIpMulticastSourceFilterAddress1, + pt3080CommsGbeAdminIpMulticastSourceFilterAddress2, + pt3080CommsGbeAdminIpMulticastSourceFilterAddress3, + pt3080CommsGbeAdminIpMulticastSourceFilterAddress4, + pt3080CommsGbeAdminIpMulticastSourceFilterAddress5, + pt3080CommsGbeAdminIpMulticastSourceFilterAddress6, + pt3080CommsGbeAdminVlanEnable, + pt3080CommsGbeAdminVlanId, + pt3080CommsGbeAdminServiceSNMP, + pt3080CommsGbeAdminServiceSCPI, + pt3080CommsGbeAdminServiceTSoIP, + pt3080CommsGbeAdminServiceWeb, + pt3080CommsGbeAdminServiceRIP, + pt3080CommsGbeAdminCurrentIpAddr, + pt3080CommsGbeAdminCurrentNetmask, + pt3080CommsBackupEnable, + pt3080CommsBackupPhysicalInterface, + pt3080CommsBackupDhcpMode, + pt3080CommsBackupStaticIpAddr, + pt3080CommsBackupStaticNetmask, + pt3080CommsBackupIpMulticastAddr, + pt3080CommsBackupIpMulticastSourceFilterMode, + pt3080CommsBackupIpMulticastSourceFilterAddress1, + pt3080CommsBackupIpMulticastSourceFilterAddress2, + pt3080CommsBackupIpMulticastSourceFilterAddress3, + pt3080CommsBackupIpMulticastSourceFilterAddress4, + pt3080CommsBackupIpMulticastSourceFilterAddress5, + pt3080CommsBackupIpMulticastSourceFilterAddress6, + pt3080CommsBackupVlanEnable, + pt3080CommsBackupVlanId, + pt3080CommsBackupServiceSNMP, + pt3080CommsBackupServiceSCPI, + pt3080CommsBackupServiceTSoIP, + pt3080CommsBackupServiceWeb, + pt3080CommsBackupServiceRIP, + pt3080CommsBackupCurrentIpAddr, + pt3080CommsBackupCurrentNetmask, + pt3080CommsPortEnable, + pt3080CommsPortPhysicalInterface, + pt3080CommsPortDhcpMode, + pt3080CommsPortStaticIpAddr, + pt3080CommsPortStaticNetmask, + pt3080CommsPortIpMulticastAddr, + pt3080CommsPortIpMulticastSourceFilterMode, + pt3080CommsPortIpMulticastSourceFilterAddress1, + pt3080CommsPortIpMulticastSourceFilterAddress2, + pt3080CommsPortIpMulticastSourceFilterAddress3, + pt3080CommsPortIpMulticastSourceFilterAddress4, + pt3080CommsPortIpMulticastSourceFilterAddress5, + pt3080CommsPortIpMulticastSourceFilterAddress6, + pt3080CommsPortVlanEnable, + pt3080CommsPortVlanId, + pt3080CommsPortServiceSNMP, + pt3080CommsPortServiceSCPI, + pt3080CommsPortServiceTSoIP, + pt3080CommsPortServiceWeb, + pt3080CommsPortServiceRIP, + pt3080CommsPortCurrentIpAddr, + pt3080CommsPortCurrentNetmask, + pt3080CommsSNMPServicePort, + pt3080CommsSNMPReadOnlyCommunity, + pt3080CommsSNMPReadWriteCommunity, + pt3080CommsSNMPTrapCommunity, + pt3080CommsSNMPTrapDestination, + pt3080CommsSNMPTrapDestination2, + pt3080CommsSNMPTrapDestination3, + pt3080CommsSNMPTrapDestination4, + pt3080CommsSNMPTrapDestination5, + pt3080CommsSNMPTrapDestinationPort, + pt3080CommsSNMPTrapDestinationPort2, + pt3080CommsSNMPTrapDestinationPort3, + pt3080CommsSNMPTrapDestinationPort4, + pt3080CommsSNMPTrapDestinationPort5, + pt3080CommsStaticGateway, + pt3080CommsCurrentGateway, + pt3080CommsStaticHostname, + pt3080CommsCurrentHostname, + pt3080CommsStaticDNSDomain, + pt3080CommsCurrentDNSDomain, + pt3080CommsStaticDNS1ServerAddress, + pt3080CommsStaticDNS2ServerAddress, + pt3080CommsStaticDNS3ServerAddress, + pt3080CommsCurrentDNS1ServerAddress, + pt3080CommsCurrentDNS2ServerAddress, + pt3080CommsCurrentDNS3ServerAddress, + pt3080CommsStaticNtpServerAddress, + pt3080CommsCurrentNtpServerAddress, + pt3080CommsEmailServerAddress, + pt3080CommsWebServicePort, + pt3080CommsSCPIServicePort, + pt3080CommsSCPIServerBaudrate, + pt3080CommsSCPIUartInterface, + pt3080CommsRipPort, + pt3080CommsIGMPVersion, + pt3080CommsIGMPQueryRobustnessCount, + pt3080CommsIGMPv3UnsolicitedReportInterval, + pt3080CommsIGMPv2UnsolicitedReportInterval, + pt3080CommsAccessAllowed, + pt3080CommsAccessAllowedTimeout, + pt3080CommsAccessAllowedTimeLeft + } + STATUS current + DESCRIPTION + "Data network communications group" + ::= { pt3080Groups 17} + + pt3080DemodulatorGroup OBJECT-GROUP + OBJECTS { + pt3080DemodulatorFollowMode, + pt3080Demodulator1Available, + pt3080Demodulator2Available, + pt3080Demodulator1FWVersion, + pt3080Demodulator2FWVersion, + pt3080Demodulator1OutputTS, + pt3080Demodulator2OutputTS, + pt3080Demodulator1MerLimit, + pt3080Demodulator2MerLimit, + pt3080Demodulator1PreVirterbiErrorRateLimit, + pt3080Demodulator2PreVirterbiErrorRateLimit, + pt3080Demodulator1PostVirterbiErrorRateLimit, + pt3080Demodulator2PostVirterbiErrorRateLimit, + pt3080Demodulator1FelStatus, + pt3080Demodulator2FelStatus, + pt3080Demodulator1UncorrectedPackets, + pt3080Demodulator2UncorrectedPackets, + pt3080Demodulator1Mer, + pt3080Demodulator2Mer, + pt3080Demodulator1PreVirterbiErrorRate, + pt3080Demodulator2PreVirterbiErrorRate, + pt3080Demodulator1PostVirterbiErrorRate, + pt3080Demodulator2PostVirterbiErrorRate, + pt3080Demodulator1ActualGuardInterval, + pt3080Demodulator2ActualGuardInterval, + pt3080Demodulator1Actualifft, + pt3080Demodulator2Actualifft, + pt3080Demodulator1ActualConstellation, + pt3080Demodulator2ActualConstellation, + pt3080Demodulator1ActualHierarchy, + pt3080Demodulator2ActualHierarchy, + pt3080Demodulator1ActualCodeRateHighPrio, + pt3080Demodulator2ActualCodeRateHighPrio, + pt3080Demodulator1ActualCodeRateLowPrio, + pt3080Demodulator2ActualCodeRateLowPrio, + pt3080Demodulator1ActualDeepInterleaver, + pt3080Demodulator2ActualDeepInterleaver, + pt3080Demodulator1ActualMpeFecHighPrio, + pt3080Demodulator2ActualMpeFecHighPrio, + pt3080Demodulator1ActualMpeFecLowPrio, + pt3080Demodulator2ActualMpeFecLowPrio, + pt3080Demodulator1ActualTimeSlicingHighPrio, + pt3080Demodulator2ActualTimeSlicingHighPrio, + pt3080Demodulator1ActualTimeSlicingLowPrio, + pt3080Demodulator2ActualTimeSlicingLowPrio, + pt3080Demodulator1ActualCellID, + pt3080Demodulator2ActualCellID, + pt3080Demodulator1ActualDVBHMode, + pt3080Demodulator2ActualDVBHMode + } + STATUS current + DESCRIPTION + "Demodulator group" + ::= { pt3080Groups 24} + + pt3080PrecorrectorGroup OBJECT-GROUP + OBJECTS { + pt3080PrecorrectorLastTurnAroundTime, + pt3080PrecorrectorSecondsSinceLastUpdate, + pt3080PrecorrectorLinCleanrun, + pt3080PrecorrectorNlinCleanrun, + pt3080PrecorrectorLinearLoadNeutral, + pt3080PrecorrectorLinearLoadFactory, + pt3080PrecorrectorLinearUpdateFactoryCurve, + pt3080PrecorrectorNonlinearLoadNeutral, + pt3080PrecorrectorNonlinearLoadFactory, + pt3080PrecorrectorNonlinearUpdateFactoryCurve, + pt3080PrecorrectorLinearAdaptive, + pt3080PrecorrectorLinearMode, + pt3080PrecorrectorLinearSenseEnable, + pt3080PrecorrectorLinearMonitorStatus, + pt3080PrecorrectorLinearMonitorSenseLevel, + pt3080PrecorrectorLinearMonitorSenseValid, + pt3080PrecorrectorLinearMonitorSenseBadCount, + pt3080PrecorrectorLinearMonitorAmplitudeRipple, + pt3080PrecorrectorLinearMonitorAmplitudeRippleValid, + pt3080PrecorrectorLinearMonitorGroupDelay, + pt3080PrecorrectorLinearMonitorGroupDelayValid, + pt3080PrecorrectorLinearMonitorDiscartedIterations, + pt3080PrecorrectorLinearMonitorIterations, + pt3080PrecorrectorLinearAdaptiveMode, + pt3080PrecorrectorLinearAdaptiveAmplitudeRippleTargetLevel, + pt3080PrecorrectorLinearAdaptiveAmplitudeRippleTargetHysteresis, + pt3080PrecorrectorLinearAdaptiveAmplitudeRippleEnable, + pt3080PrecorrectorLinearAdaptiveGroupDelayTargetLevel, + pt3080PrecorrectorLinearAdaptiveGroupDelayTargetHysteresis, + pt3080PrecorrectorLinearAdaptiveGroupDelayEnable, + pt3080PrecorrectorLinearAttenuation, + pt3080PrecorrectorNonlinearAdaptive, + pt3080PrecorrectorNonlinearMode, + pt3080PrecorrectorNonlinearSenseEnable, + pt3080PrecorrectorNonlinearMonitorStatus, + pt3080PrecorrectorNonlinearMonitorSenseLevel, + pt3080PrecorrectorNonlinearMonitorSenseValid, + pt3080PrecorrectorNonlinearMonitorSenseBadCount, + pt3080PrecorrectorNonlinearMonitorLowerShoulderLevel, + pt3080PrecorrectorNonlinearMonitorLowerShoulderValid, + pt3080PrecorrectorNonlinearMonitorUpperShoulderLevel, + pt3080PrecorrectorNonlinearMonitorUpperShoulderValid, + pt3080PrecorrectorNonlinearMonitorDiscartedIterations, + pt3080PrecorrectorNonlinearMonitorIterations, + pt3080PrecorrectorNonlinearMonitorMer, + pt3080PrecorrectorNonlinearMonitorMerValid, + pt3080PrecorrectorNonlinearMonitorPapr, + pt3080PrecorrectorNonlinearMonitorPaprValid, + pt3080PrecorrectorNonlinearAttenuation, + pt3080PrecorrectorNonlinearAdaptiveMode, + pt3080PrecorrectorNonlinearAdaptiveAveraging, + pt3080PrecorrectorNonlinearAdaptiveMaxRfPaprEnable, + pt3080PrecorrectorNonlinearAdaptiveMaxRfPaprLimit, + pt3080PrecorrectorNonlinearAdaptiveMerTarget, + pt3080PrecorrectorNonlinearAdaptiveMerTargetHysteresis, + pt3080PrecorrectorNonlinearAdaptiveMerEnable, + pt3080PrecorrectorNonlinearAdaptiveLowerShoulderTargetLevel, + pt3080PrecorrectorNonlinearAdaptiveLowerShoulderTargetHysteresis, + pt3080PrecorrectorNonlinearAdaptiveLowerShoulderEnable, + pt3080PrecorrectorNonlinearAdaptiveUpperShoulderTargetLevel, + pt3080PrecorrectorNonlinearAdaptiveUpperShoulderTargetHysteresis, + pt3080PrecorrectorNonlinearAdaptiveUpperShoulderEnable, + pt3080PrecorrectorPaprClipping, + pt3080PrecorrectorPaprShaping, + pt3080PrecorrectorClipperMode, + pt3080PrecorrectorClipperAdaptive, + pt3080PrecorrectorClipperEnable, + pt3080PrecorrectorClipperAdaptiveMode, + pt3080PrecorrectorClipperAdaptiveShaping, + pt3080PrecorrectorClipperMonitorStatus, + pt3080PrecorrectorClipperMonitorShoulderLevelLower, + pt3080PrecorrectorClipperMonitorShoulderLevelLowerValid, + pt3080PrecorrectorClipperMonitorShoulderLevelUpper, + pt3080PrecorrectorClipperMonitorShoulderLevelUpperValid, + pt3080PrecorrectorClipperMonitorMer, + pt3080PrecorrectorClipperMonitorMerValid, + pt3080PrecorrectorClipperMonitorPapr, + pt3080PrecorrectorClipperMonitorPaprValid, + pt3080PrecorrectorClipperMonitorIterations + } + STATUS current + DESCRIPTION + "Precorrector group" + ::= { pt3080Groups 25} + + pt3080ReceptionGroup OBJECT-GROUP + OBJECTS { + pt3080ReceptionGainControl, + pt3080ReceptionGainManualValue, + pt3080ReceptionGainLimitEnable, + pt3080ReceptionGainLimit, + pt3080ReceptionGainCurrent, + pt3080ReceptionAGCMode, + pt3080ReceptionAGCHysteresis, + pt3080ReceptionBandwidth, + pt3080ReceptionRFFrequency, + pt3080ReceptionRFFrequencyOffset, + pt3080ReceptionRFPolarity, + pt3080ReceptionRFSquelchEnable, + pt3080ReceptionRFSquelchThreshold, + pt3080ReceptionRFSquelchHysteresis, + pt3080ReceptionRFTrackingFilterEnable, + pt3080ReceptionRFifLevel, + pt3080ReceptionRFNominalInputLevel, + pt3080ReceptionRFInputLevel, + pt3080ReceptionRFInputLevelThreshold, + pt3080ReceptionRFInputLevelHysteresis, + pt3080ReceptionIFFrequency, + pt3080ReceptionIFPolarity, + pt3080ReceptionIFInputLevel, + pt3080ReceptionIFInputPolicy, + pt3080ReceptionIFInput, + pt3080ReceptionIFRFtoIFHoldoverDelay, + pt3080ReceptionIFIFtoRFHoldoverDelay, + pt3080ReceptionTunerHWVersion, + pt3080ReceptionTunerHWType, + pt3080ReceptionTunerHWID, + pt3080ReceptionTunerHWSerialNumber, + pt3080ReceptionTunerHWCalibrationDate, + pt3080ReceptionTunerHWCalibrationDataVersion, + pt3080ReceptionTunerHWCalibrationSWVersion + } + STATUS current + DESCRIPTION + "Reception group" + ::= { pt3080Groups 26} + + pt3080BackplaneGroup OBJECT-GROUP + OBJECTS { + pt3080BackplanePolarityHardMute, + pt3080BackplanePolarityRFFail + } + STATUS current + DESCRIPTION + "Backplane group" + ::= { pt3080Groups 27} + + + pt3080ASIGroup OBJECT-GROUP + OBJECTS { + pt3080ASIInput1SyncTimeout, + pt3080ASIInput2SyncTimeout, + pt3080ASIInput1DataErrorLimit, + pt3080ASIInput2DataErrorLimit, + pt3080ASIInput1SyncStatus, + pt3080ASIInput2SyncStatus, + pt3080ASIInput1SyncSignal, + pt3080ASIInput2SyncSignal, + pt3080ASIInput1SyncTSSize, + pt3080ASIInput2SyncTSSize, + pt3080ASIInput1LineErrors, + pt3080ASIInput2LineErrors, + pt3080ASIInput1LineRate, + pt3080ASIInput2LineRate, + pt3080ASIInput1LineErrorRate, + pt3080ASIInput2LineErrorRate, + pt3080ASIInput1DataErrors, + pt3080ASIInput2DataErrors, + pt3080ASIInput1DataRate, + pt3080ASIInput2DataRate, + pt3080ASIInput1DataErrorRate, + pt3080ASIInput2DataErrorRate, + pt3080ASIInput1ClearErrorCounters, + pt3080ASIInput2ClearErrorCounters + } + STATUS current + DESCRIPTION + "ASI media group" + ::= { pt3080Groups 30} + + pt3080NotifsGroup OBJECT-GROUP + OBJECTS { + pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime + } + STATUS current + DESCRIPTION + "Notification objects group" + ::= { pt3080Groups 64 } + +-- +-- Agent Capability +-- +pt3080Agent AGENT-CAPABILITIES + PRODUCT-RELEASE "SWPROTELEVISION_P3_1_02_157 build 1441106393" + STATUS current + DESCRIPTION "PT2080 DVB-T/H Modulator agent" + SUPPORTS PT2080-MIB + INCLUDES { + pt3080SystemGroup, + pt3080ModeGroup, + pt3080GpsGroup, + pt3080ChannelFilterGroup, + pt3080TSoIPGroup, + pt3080MonitorGroup, + pt3080TestGroup, + pt3080AlarmGroup, + pt3080PresetGroup, + pt3080EventlogGroup, + pt3080CommsGroup, + pt3080DemodulatorGroup, + pt3080BackplaneGroup, + pt3080ReceptionGroup, + pt3080ASIGroup + } +::= { pt3080Conformance 3 } + + +-- +-- System Notifications (aka Traps) +-- +pt3080NotificationsGroups OBJECT IDENTIFIER ::= { pt3080Conformance 4 } + +pt3080NotifModulatorAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Modulator Alarms" + ::= { pt3080Notif 3 } + +pt3080NotifTSPrimaryAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "ASI TS Primary Alarms" + ::= { pt3080Notif 5 } + +pt3080NotifTSSecondaryAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "ASI TS Secondary Alarms" + ::= { pt3080Notif 6 } + +pt3080NotifSFNAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "SFN Alarms" + ::= { pt3080Notif 7 } + +pt3080NotifRefenceClockAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Reference Alarms" + ::= { pt3080Notif 8 } + +pt3080NotifRFAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "RF Alarms" + ::= { pt3080Notif 9 } + +pt3080NotifGNSSAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "GNSS Alarms" + ::= { pt3080Notif 10 } + +pt3080NotifTSoIPAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TSoIP Alarms" + ::= { pt3080Notif 12 } + +pt3080NotifExternalAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "External Alarms" + ::= { pt3080Notif 13 } + +pt3080NotifHWMonitorAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "HW Monitor Alarms" + ::= { pt3080Notif 14 } + +pt3080NotifCommAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Communications Alarms" + ::= { pt3080Notif 15 } + +pt3080NotifASIAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "ASI Alarms" + ::= { pt3080Notif 16 } + +pt3080NotifInternalAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Internal Alarms" + ::= { pt3080Notif 18 } + +pt3080NotifTSPrimarySyncLossAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Primary Sync Loss" + ::= { pt3080Notif 21 } + +pt3080NotifTSPrimarySyncErrorAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Primary Sync Error" + ::= { pt3080Notif 22 } + +pt3080NotifTSPrimaryPCRErrorAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Primary PCR Error" + ::= { pt3080Notif 23 } + +pt3080NotifTSPrimaryPATLossAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Primary PAT Loss" + ::= { pt3080Notif 24 } + +pt3080NotifTSPrimaryTSIDWrongAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Primary Transport Stream ID" + ::= { pt3080Notif 25 } + +pt3080NotifTSPrimaryNWIDWrongAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Primary Network ID" + ::= { pt3080Notif 26 } + +pt3080NotifTSPrimaryStuffingRateExceededAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Primary Stuffing Rate" + ::= { pt3080Notif 27 } + +pt3080NotifTSPrimaryBufferPoolExceededAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Primary Buffer Pool" + ::= { pt3080Notif 28 } + +pt3080NotifTSPrimarySTSJitterExceededAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Primary STS Jitter" + ::= { pt3080Notif 29 } + +pt3080NotifTSPrimaryMIPDataMissingAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Primary MIP Data Missing" + ::= { pt3080Notif 30 } + +pt3080NotifTSPrimaryMIPPriorityBadAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Primary Bad Priority in MIP" + ::= { pt3080Notif 31 } + +pt3080NotifTSSecondarySyncLossAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Secondary Sync Loss" + ::= { pt3080Notif 32 } + +pt3080NotifTSSecondarySyncErrorAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Secondary Sync Error" + ::= { pt3080Notif 33 } + +pt3080NotifTSSecondaryPCRErrorAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Secondary PCR Error" + ::= { pt3080Notif 34 } + +pt3080NotifTSSecondaryPATLossAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Secondary PAT Loss" + ::= { pt3080Notif 35 } + +pt3080NotifTSSecondaryTSIDWrongAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Secondary Transport Stream ID" + ::= { pt3080Notif 36 } + +pt3080NotifTSSecondaryNWIDWrongAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Secondary Network ID" + ::= { pt3080Notif 37 } + +pt3080NotifTSSecondaryStuffingRateExceededAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Secondary Stuffing Rate" + ::= { pt3080Notif 38 } + +pt3080NotifTSSecondaryBufferPoolExceededAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Secondary Buffer Pool" + ::= { pt3080Notif 39 } + +pt3080NotifTSSecondarySTSJitterExceededAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Secondary STS Jitter" + ::= { pt3080Notif 40 } + +pt3080NotifTSSecondaryMIPDataMissingAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Secondary MIP Data Missing" + ::= { pt3080Notif 41 } + +pt3080NotifTSSecondaryMIPPriorityBadAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Secondary Bad Priority in MIP" + ::= { pt3080Notif 42 } + +pt3080NotifRFOverloadProtectionAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Overload Protection" + ::= { pt3080Notif 44 } + +pt3080NotifCommeth0Alarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "ETH0 Conn. State" + ::= { pt3080Notif 55 } + +pt3080NotifCommeth1Alarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "ETH1 Conn. State" + ::= { pt3080Notif 56 } + +pt3080NotifCommeth2Alarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "ETH2 Conn. State" + ::= { pt3080Notif 57 } + +pt3080NotifCommeth3Alarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "ETH3 Conn. State" + ::= { pt3080Notif 58 } + +pt3080NotifCommeth4Alarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "ETH4 Conn. State" + ::= { pt3080Notif 59 } + +pt3080NotifExternalInput1Alarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Alarm Input 1" + ::= { pt3080Notif 72 } + +pt3080NotifExternalInput2Alarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Alarm Input 2" + ::= { pt3080Notif 73 } + +pt3080NotifExternalInput3Alarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Alarm Input 3" + ::= { pt3080Notif 74 } + +pt3080NotifExternalInput4Alarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Alarm Input 4" + ::= { pt3080Notif 75 } + +pt3080NotifRefenceClockExtern1PPSLossAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Ext. 1PPS Loss" + ::= { pt3080Notif 76 } + +pt3080NotifRefenceClockIntern1PPSLossAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Int. 10MHz Loss" + ::= { pt3080Notif 77 } + +pt3080NotifRefenceClockExtern10MHzLossAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Ext. 10MHz Loss" + ::= { pt3080Notif 78 } + +pt3080NotifRFAlcRangeAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "ALC Range" + ::= { pt3080Notif 79 } + +pt3080NotifSFNResyncAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "SFN Resync Error" + ::= { pt3080Notif 80 } + +pt3080NotifSFNTSPrimaryMaxDelayOffsetExceededAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Primary SFN Max Delay + Offset OOR" + ::= { pt3080Notif 81 } + +pt3080NotifSFNTSPrimaryNetworkDelayExceededAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Primary SFN NW Delay Greater Than Max" + ::= { pt3080Notif 82 } + +pt3080NotifSFNTSSecondaryMaxDelayOffsetExceededAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Secondary SFN Max. Delay + Offset OOR" + ::= { pt3080Notif 84 } + +pt3080NotifSFNTSSecondaryNetworkDelayExceededAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Secondary SFN NW Delay Greater Than Max" + ::= { pt3080Notif 85 } + +pt3080NotifRFLevelOutOfRangeAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "RF Level Out of Range" + ::= { pt3080Notif 87 } + +pt3080NotifRefenceClockNTPSyncLossAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "NTP Sync Loss" + ::= { pt3080Notif 89 } + +pt3080NotifSFNTSPrimarySeamlessDelayTooSmallAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Primary Delay Margin too Small for Seamless and Holdover" + ::= { pt3080Notif 92 } + +pt3080NotifSFNTSPrimaryMIPConfigErrorAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Primary SFN and MIP Config Differ" + ::= { pt3080Notif 93 } + +pt3080NotifSFNTSSecondarySeamlessDelayTooSmallAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Secondary Delay Margin too Small for Seamless and Holdover" + ::= { pt3080Notif 94 } + +pt3080NotifSFNTSSecondaryMIPConfigErrorAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Secondary SFN and MIP Config Differ" + ::= { pt3080Notif 95 } + +pt3080NotifGNSSUnlockedAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "GNSS Unlocked" + ::= { pt3080Notif 98 } + +pt3080NotifGNSSAntennaFaultAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "GNSS Antenna Fault" + ::= { pt3080Notif 107 } + +pt3080NotifGNSSHoldOverAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "GNSS Holdover" + ::= { pt3080Notif 108 } + +pt3080NotifRefenceClockExternal10MHzHoldOverAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Ext. 10MHz Ref Holdover" + ::= { pt3080Notif 109 } + +pt3080NotifRefenceClockExternal1PPSHoldOverAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Ext. 1PPS Ref Holdover" + ::= { pt3080Notif 110 } + +pt3080NotifASIASI1ErrorRateEceeededAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "ASI-IN1 Error Rate" + ::= { pt3080Notif 113 } + +pt3080NotifASIASI2ErrorRateEceeededAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "ASI-IN2 Error Rate" + ::= { pt3080Notif 114 } + +pt3080NotifTSoIPRx1PackageErrorRationExceededAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TSoIP RX1 Package Error Ratio Exceeded" + ::= { pt3080Notif 115 } + +pt3080NotifTSoIPRx2PackageErrorRationExceededAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TSoIP RX2 Package Error Ratio Exceeded" + ::= { pt3080Notif 117 } + +pt3080NotifTSoIPRx1SyncLossAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TSoIP RX1 Signal Loss" + ::= { pt3080Notif 119 } + +pt3080NotifTSoIPRx2SyncLossAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TSoIP RX2 Signal Loss" + ::= { pt3080Notif 121 } + +pt3080NotifInternalBackplaneAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Backplane Status" + ::= { pt3080Notif 129 } + +pt3080NotifInternalReferenceClockAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Reference Status" + ::= { pt3080Notif 132 } + +pt3080NotifInternalUpConverterAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Upconverter Status" + ::= { pt3080Notif 134 } + +pt3080NotifInternalDownConverterAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Downconverter Status" + ::= { pt3080Notif 135 } + +pt3080NotifInternalMainboardAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Main board Status" + ::= { pt3080Notif 136 } + +pt3080NotifInternalBatteryAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Main Board Battery" + ::= { pt3080Notif 137 } + +pt3080NotifInternalFirmware1Alarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Firmware 1 Status" + ::= { pt3080Notif 139 } + +pt3080NotifInternalGNSSAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "GNSS Status" + ::= { pt3080Notif 142 } + +pt3080NotifInternalSatelliteAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Satrecv Status" + ::= { pt3080Notif 143 } + +pt3080NotifInternalEthAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "EtherNet Port Failure" + ::= { pt3080Notif 146 } + +pt3080NotifHWMonitorFPGAAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Main Board FPGA Temperature" + ::= { pt3080Notif 156 } + +pt3080NotifHWMonitorMainBoardCPUTemperatureAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Main Board CPU Temperature" + ::= { pt3080Notif 157 } + +pt3080NotifHWMonitorMainBoardTemperatureAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Main Board Temperature" + ::= { pt3080Notif 158 } + +pt3080NotifHWMonitorLeftFanAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Left Chassis Fan" + ::= { pt3080Notif 159 } + +pt3080NotifHWMonitorRightFan2Alarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Right Chassis Fan" + ::= { pt3080Notif 160 } + +pt3080NotifHWMonitorBackplaneTemperatureAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Backplane Temperature" + ::= { pt3080Notif 162 } + +pt3080NotifTSPrimaryInputTSHoldOverAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Input TS Holdover" + ::= { pt3080Notif 180 } + +pt3080NotifInternalPLLUnlockedAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "PLL Out of Lock" + ::= { pt3080Notif 182 } + +pt3080NotifExternalInput5Alarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Alarm Input 5" + ::= { pt3080Notif 183 } + +pt3080NotifSFNUntimedModeAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "SFN Mode Untimed" + ::= { pt3080Notif 184 } + +pt3080NotifSFNFreeRunningModeAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "SFN Mode Free Running" + ::= { pt3080Notif 185 } + +pt3080NotifExternalInput6Alarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Alarm Input 6" + ::= { pt3080Notif 186 } + +pt3080NotifExternalInput7Alarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Alarm Input 7" + ::= { pt3080Notif 187 } + +pt3080NotifExternalInput8Alarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "Alarm Input 8" + ::= { pt3080Notif 188 } + +pt3080NotifTSPrimaryDelayMarginAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Primary Delay Margin" + ::= { pt3080Notif 190 } + +pt3080NotifTSSecondaryDelayMarginAlarm NOTIFICATION-TYPE + OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime } + STATUS current + DESCRIPTION + "TS Secondary Delay Margin" + ::= { pt3080Notif 191 } + +pt3080NotifGroupModulatorAlarm NOTIFICATION-GROUP + NOTIFICATIONS { + pt3080NotifModulatorAlarm + } + STATUS current + DESCRIPTION + "Modulator Alarms" + ::= { pt3080NotificationsGroups 3 } + +pt3080NotifGroupTSPrimaryAlarm NOTIFICATION-GROUP + NOTIFICATIONS { + pt3080NotifTSPrimaryAlarm, + pt3080NotifTSPrimarySyncLossAlarm, + pt3080NotifTSPrimarySyncErrorAlarm, + pt3080NotifTSPrimaryPCRErrorAlarm, + pt3080NotifTSPrimaryPATLossAlarm, + pt3080NotifTSPrimaryTSIDWrongAlarm, + pt3080NotifTSPrimaryNWIDWrongAlarm, + pt3080NotifTSPrimaryStuffingRateExceededAlarm, + pt3080NotifTSPrimaryBufferPoolExceededAlarm, + pt3080NotifTSPrimarySTSJitterExceededAlarm, + pt3080NotifTSPrimaryMIPDataMissingAlarm, + pt3080NotifTSPrimaryMIPPriorityBadAlarm, + pt3080NotifTSPrimaryInputTSHoldOverAlarm, + pt3080NotifTSPrimaryDelayMarginAlarm + } + STATUS current + DESCRIPTION + "ASI TS Primary Alarms" + ::= { pt3080NotificationsGroups 5 } + +pt3080NotifGroupTSSecondaryAlarm NOTIFICATION-GROUP + NOTIFICATIONS { + pt3080NotifTSSecondaryAlarm, + pt3080NotifTSSecondarySyncLossAlarm, + pt3080NotifTSSecondarySyncErrorAlarm, + pt3080NotifTSSecondaryPCRErrorAlarm, + pt3080NotifTSSecondaryPATLossAlarm, + pt3080NotifTSSecondaryTSIDWrongAlarm, + pt3080NotifTSSecondaryNWIDWrongAlarm, + pt3080NotifTSSecondaryStuffingRateExceededAlarm, + pt3080NotifTSSecondaryBufferPoolExceededAlarm, + pt3080NotifTSSecondarySTSJitterExceededAlarm, + pt3080NotifTSSecondaryMIPDataMissingAlarm, + pt3080NotifTSSecondaryMIPPriorityBadAlarm, + pt3080NotifTSSecondaryDelayMarginAlarm + } + STATUS current + DESCRIPTION + "ASI TS Secondary Alarms" + ::= { pt3080NotificationsGroups 6 } + +pt3080NotifGroupSFNAlarm NOTIFICATION-GROUP + NOTIFICATIONS { + pt3080NotifSFNAlarm, + pt3080NotifSFNResyncAlarm, + pt3080NotifSFNTSPrimaryMaxDelayOffsetExceededAlarm, + pt3080NotifSFNTSPrimaryNetworkDelayExceededAlarm, + pt3080NotifSFNTSSecondaryMaxDelayOffsetExceededAlarm, + pt3080NotifSFNTSSecondaryNetworkDelayExceededAlarm, + pt3080NotifSFNTSPrimarySeamlessDelayTooSmallAlarm, + pt3080NotifSFNTSPrimaryMIPConfigErrorAlarm, + pt3080NotifSFNTSSecondarySeamlessDelayTooSmallAlarm, + pt3080NotifSFNTSSecondaryMIPConfigErrorAlarm, + pt3080NotifSFNUntimedModeAlarm, + pt3080NotifSFNFreeRunningModeAlarm + } + STATUS current + DESCRIPTION + "SFN Alarms" + ::= { pt3080NotificationsGroups 7 } + +pt3080NotifGroupRefenceClockAlarm NOTIFICATION-GROUP + NOTIFICATIONS { + pt3080NotifRefenceClockAlarm, + pt3080NotifRefenceClockExtern1PPSLossAlarm, + pt3080NotifRefenceClockIntern1PPSLossAlarm, + pt3080NotifRefenceClockExtern10MHzLossAlarm, + pt3080NotifRefenceClockNTPSyncLossAlarm, + pt3080NotifRefenceClockExternal10MHzHoldOverAlarm, + pt3080NotifRefenceClockExternal1PPSHoldOverAlarm + } + STATUS current + DESCRIPTION + "Reference Alarms" + ::= { pt3080NotificationsGroups 8 } + +pt3080NotifGroupRFAlarm NOTIFICATION-GROUP + NOTIFICATIONS { + pt3080NotifRFAlarm, + pt3080NotifRFOverloadProtectionAlarm, + pt3080NotifRFAlcRangeAlarm, + pt3080NotifRFLevelOutOfRangeAlarm + } + STATUS current + DESCRIPTION + "RF Alarms" + ::= { pt3080NotificationsGroups 9 } + +pt3080NotifGroupGNSSAlarm NOTIFICATION-GROUP + NOTIFICATIONS { + pt3080NotifGNSSAlarm, + pt3080NotifGNSSUnlockedAlarm, + pt3080NotifGNSSAntennaFaultAlarm, + pt3080NotifGNSSHoldOverAlarm + } + STATUS current + DESCRIPTION + "GNSS Alarms" + ::= { pt3080NotificationsGroups 10 } + +pt3080NotifGroupTSoIPAlarm NOTIFICATION-GROUP + NOTIFICATIONS { + pt3080NotifTSoIPAlarm, + pt3080NotifTSoIPRx1PackageErrorRationExceededAlarm, + pt3080NotifTSoIPRx2PackageErrorRationExceededAlarm, + pt3080NotifTSoIPRx1SyncLossAlarm, + pt3080NotifTSoIPRx2SyncLossAlarm + } + STATUS current + DESCRIPTION + "TSoIP Alarms" + ::= { pt3080NotificationsGroups 12 } + +pt3080NotifGroupExternalAlarm NOTIFICATION-GROUP + NOTIFICATIONS { + pt3080NotifExternalAlarm, + pt3080NotifExternalInput1Alarm, + pt3080NotifExternalInput2Alarm, + pt3080NotifExternalInput3Alarm, + pt3080NotifExternalInput4Alarm, + pt3080NotifExternalInput5Alarm, + pt3080NotifExternalInput6Alarm, + pt3080NotifExternalInput7Alarm, + pt3080NotifExternalInput8Alarm + } + STATUS current + DESCRIPTION + "External Alarms" + ::= { pt3080NotificationsGroups 13 } + +pt3080NotifGroupHWMonitorAlarm NOTIFICATION-GROUP + NOTIFICATIONS { + pt3080NotifHWMonitorAlarm, + pt3080NotifHWMonitorFPGAAlarm, + pt3080NotifHWMonitorMainBoardCPUTemperatureAlarm, + pt3080NotifHWMonitorMainBoardTemperatureAlarm, + pt3080NotifHWMonitorLeftFanAlarm, + pt3080NotifHWMonitorRightFan2Alarm, + pt3080NotifHWMonitorBackplaneTemperatureAlarm + } + STATUS current + DESCRIPTION + "HW Monitor Alarms" + ::= { pt3080NotificationsGroups 14 } + +pt3080NotifGroupCommAlarm NOTIFICATION-GROUP + NOTIFICATIONS { + pt3080NotifCommAlarm, + pt3080NotifCommeth0Alarm, + pt3080NotifCommeth1Alarm, + pt3080NotifCommeth2Alarm, + pt3080NotifCommeth3Alarm, + pt3080NotifCommeth4Alarm + } + STATUS current + DESCRIPTION + "Communications Alarms" + ::= { pt3080NotificationsGroups 15 } + +pt3080NotifGroupASIAlarm NOTIFICATION-GROUP + NOTIFICATIONS { + pt3080NotifASIAlarm, + pt3080NotifASIASI1ErrorRateEceeededAlarm, + pt3080NotifASIASI2ErrorRateEceeededAlarm + } + STATUS current + DESCRIPTION + "ASI Alarms" + ::= { pt3080NotificationsGroups 16 } + +pt3080NotifGroupInternalAlarm NOTIFICATION-GROUP + NOTIFICATIONS { + pt3080NotifInternalAlarm, + pt3080NotifInternalBackplaneAlarm, + pt3080NotifInternalReferenceClockAlarm, + pt3080NotifInternalUpConverterAlarm, + pt3080NotifInternalDownConverterAlarm, + pt3080NotifInternalMainboardAlarm, + pt3080NotifInternalBatteryAlarm, + pt3080NotifInternalFirmware1Alarm, + pt3080NotifInternalGNSSAlarm, + pt3080NotifInternalSatelliteAlarm, + pt3080NotifInternalEthAlarm, + pt3080NotifInternalPLLUnlockedAlarm + } + STATUS current + DESCRIPTION + "Internal Alarms" + ::= { pt3080NotificationsGroups 18 } + +END -- cgit v1.2.3