From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/ray/RAY-MIB | 1148 ++++++++++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 1148 insertions(+) create mode 100644 MIBS/ray/RAY-MIB (limited to 'MIBS/ray/RAY-MIB') diff --git a/MIBS/ray/RAY-MIB b/MIBS/ray/RAY-MIB new file mode 100644 index 0000000..e52feea --- /dev/null +++ b/MIBS/ray/RAY-MIB @@ -0,0 +1,1148 @@ +RAY-MIB DEFINITIONS ::= BEGIN + IMPORTS + enterprises, IpAddress, Gauge + FROM RFC1155-SMI + MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, + Unsigned32, TimeTicks, Counter32, Gauge32, Integer32, Counter64 + FROM SNMPv2-SMI + DateAndTime, TEXTUAL-CONVENTION + FROM SNMPv2-TC + MODULE-COMPLIANCE, OBJECT-GROUP + FROM SNMPv2-CONF + mib-2 FROM SNMPv2-SMI + snmpTraps + FROM SNMPv2-MIB; + +ray MODULE-IDENTITY + LAST-UPDATED "201610040000Z" + ORGANIZATION "Racom s.r.o" + CONTACT-INFO + "Racom s.r.o + Mirova 1283 + 592 31 Nove Mesto na Morave + Czech Republic + Tel: +420 565 659 511 + Fax: +420 565 659 512 + E-mail: racom@racom.eu" + DESCRIPTION "The MIB module defines management objects for RAy product series. Revision 201610040000Z." + REVISION "201610040000Z" + DESCRIPTION "Latest version of this MIB module" + ::= { racom 1 } + +DisplayString ::= OCTET STRING + +PhysAddress ::= OCTET STRING + +ServiceState ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "System service or device state." + SYNTAX INTEGER { + na (0), -- service/device state not available + up (1), -- service is running or device is up + down (2) -- service is not running or device is down + } + +AlarmState ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Alarm status." + SYNTAX INTEGER { + na (0), -- alarm state not available + up (1), -- alarm up + down (2), -- alarm down + ack (3) -- alarm up and acknowledged + } + +OptionSetting ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Setting of some options." + SYNTAX INTEGER { + na (0), + on (1), + off (2) + } + +ModulationList ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Radio channel modulations numerical list" + SYNTAX INTEGER { + na (0), + qpsk (1), + qam16 (2), + qam32 (3), + qam64 (4), + qam128 (5), + qam256 (6) + } + + +racom OBJECT IDENTIFIER ::= { enterprises 33555 } + +station OBJECT IDENTIFIER ::= {ray 1} +interface OBJECT IDENTIFIER ::= {ray 2} +statistic OBJECT IDENTIFIER ::= {ray 3} +rayTraps OBJECT IDENTIFIER ::= {ray 10} +ray2Traps OBJECT IDENTIFIER ::= {ray 11} + +-- station MIB + +product OBJECT IDENTIFIER ::= {station 1} +info OBJECT IDENTIFIER ::= {station 2} +status OBJECT IDENTIFIER ::= {station 3} +chassis OBJECT IDENTIFIER ::= {station 4} +system OBJECT IDENTIFIER ::= {station 5} +access OBJECT IDENTIFIER ::= {station 6} +authorization OBJECT IDENTIFIER ::= {station 7} +alarm OBJECT IDENTIFIER ::= {station 8} + +-- product MIB + +productName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Product name." + ::= { product 1 } + +serialNumber OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Product serial number." + ::= { product 2 } + +unitType OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..4)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Station type (L or H) and number of the Ethernet ports (1 or 2)." + ::= { product 3 } + +-- info MIB + +deviceName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Station name." + ::= { info 1 } + +swVer OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Firmware version." + ::= { info 2 } + +swVerRadio OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Radio firmware version." + ::= { info 3 } + +-- status mib +systemStatus OBJECT-TYPE + SYNTAX INTEGER { + na (0), + ok (1), + warning (2), + alarm (3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Unit status." + ::= { status 1 } + +lineStatus OBJECT-TYPE + SYNTAX INTEGER { + na (0), + ok (1), + analyzer (2), + connecting (3), + searching (4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Radio link status. Supported by RAy10 only." + ::= { status 2 } + +peerNumber OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Peer station serial number." + ::= { status 3 } + +rfPowerStatus OBJECT-TYPE + SYNTAX INTEGER { + na (0), + ok (1), + fail (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "RF Power amplifier OK/Failure." + ::= { status 4 } + +searchModeDisabled OBJECT-TYPE + SYNTAX OptionSetting + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Search mode disabled on/off. Supported by RAy10 only." + ::= { status 5 } + +ethPeer OBJECT-TYPE + SYNTAX ServiceState + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Peer station user Ethernet link status. Not supported by RAy2." + ::= { status 6 } + +securePeerMode OBJECT-TYPE + SYNTAX OptionSetting + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Secure peer mode. Not supported by RAy10." + ::= { status 7 } + +lineStatusII OBJECT-TYPE + SYNTAX INTEGER { + na (0), + setup (1), + single (2), + connecting (3), + authorizing (4), + ok (5), + analyzer (6) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Radio link status. Not supported by RAy10." + ::= { status 8 } + +eth1Link OBJECT-TYPE + SYNTAX ServiceState + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Ethernet 1 link status. Supported by RAy2 only." + ::= { status 9 } + +eth2Link OBJECT-TYPE + SYNTAX ServiceState + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Ethernet 2 link status. Supported by RAy2 only." + ::= { status 10 } + + +-- chassis mib +temperatureModem OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Modem temperature in hundredths of Celsius (C)." + ::= { chassis 1 } + +temperatureRadio OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Radio temperature in hundredths of Celsius (C)." + ::= { chassis 2} + +voltageUnit OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Power supply voltage in tenths of Volts (V)." + ::= { chassis 3 } + +voltageSource OBJECT-TYPE + SYNTAX INTEGER { + na (0), + aux (1), + poe (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Source of supply voltage. Supported by RAy2 only." + ::= { chassis 4 } + + +-- system mib +useCpu OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION "System use CPU in %." + ::= { system 1 } + +useMemory OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION "System use memory in %." + ::= { system 2 } + +useLogStorage OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Use storage for log in %." + ::= { system 3 } + +-- access mib +sshd OBJECT-TYPE + SYNTAX INTEGER { + on (1), + onlykey (2), + off (3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Management interface: SSH." + ::= { access 1 } + +telnetd OBJECT-TYPE + SYNTAX OptionSetting + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Management interface: Telnet." + ::= { access 2 } + +httpd OBJECT-TYPE + SYNTAX OptionSetting + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Management interface: HTTP." + ::= { access 3 } + +ip OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Management interface: IP address." + ::= { access 4 } + +mac OBJECT-TYPE + SYNTAX PhysAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Management interface: MAC address." + ::= { access 5 } + +managementVlan OBJECT-TYPE + SYNTAX OptionSetting + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Management interface: VLAN on/off." + ::= { access 6 } + +managementVlanId OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Management interface: VLAN ID." + ::= { access 7 } + +wifiHAP OBJECT-TYPE + SYNTAX OptionSetting + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Management interface: WiFi Host Access Point." + ::= { access 8 } + + +-- authorization mib +keyTable OBJECT-TYPE + SYNTAX SEQUENCE OF KeyEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "List of product key entries. Supported by RAy10 only." + ::= { authorization 1 } + +keyEntry OBJECT-TYPE + SYNTAX KeyEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Product key entry. Supported by RAy10 only." + INDEX { keyName } + ::= { keyTable 1 } + +KeyEntry ::= + SEQUENCE { + keyName DisplayString + } + +keyName OBJECT-TYPE + SYNTAX DisplayString(SIZE(1..64)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Product key name. Supported by RAy10 only." + ::= { keyEntry 1 } + +-- alarm mib +alarmTemperature OBJECT-TYPE + SYNTAX AlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Temperature alarm state. Supported by RAy2 only." + ::= { alarm 1 } + +alarmVoltageLow OBJECT-TYPE + SYNTAX AlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Low voltage alarm state. Supported by RAy2 only." + ::= { alarm 2 } + +alarmVoltageHigh OBJECT-TYPE + SYNTAX AlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION "High voltage alarm state. Supported by RAy2 only." + ::= { alarm 3 } + +alarmRss OBJECT-TYPE + SYNTAX AlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION "RSS alarm state. Supported by RAy2 only." + ::= { alarm 4 } + +alarmSnr OBJECT-TYPE + SYNTAX AlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION "SNR alarm state. Supported by RAy2 only." + ::= { alarm 5 } + +alarmBer OBJECT-TYPE + SYNTAX AlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION "BER alarm state. Supported by RAy2 only." + ::= { alarm 6 } + +alarmPeerDisconnected OBJECT-TYPE + SYNTAX AlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Peer disconnect alarm state. Supported by RAy2 only." + ::= { alarm 7 } + +alarmEth1Down OBJECT-TYPE + SYNTAX AlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Ethernet 1 Link Down alarm state. Supported by RAy2 only." + ::= { alarm 8 } + +alarmEth2Down OBJECT-TYPE + SYNTAX AlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Ethernet 2 Link Down alarm state. Supported by RAy2 only." + ::= { alarm 9 } + +alarmRfPowerFail OBJECT-TYPE + SYNTAX AlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION "RF Power Fail alarm state. Supported by RAy2 only." + ::= { alarm 10 } + +alarmNetBitrate OBJECT-TYPE + SYNTAX AlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Air Speed below Limit alarm state. Supported by RAy2 only." + ::= { alarm 11 } + +alarmWifiOn OBJECT-TYPE + SYNTAX AlarmState + MAX-ACCESS read-only + STATUS current + DESCRIPTION "WiFi Host Access Oint on. Supported by RAy2 only." + ::= { alarm 12 } + + +-- interface mib +ifRadio OBJECT IDENTIFIER ::= {interface 1} +ifEth OBJECT IDENTIFIER ::= {interface 2} + +-- radio mib +rxChannel OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..8)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Receiver channel ID." + ::= { ifRadio 1 } + +txChannel OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..8)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Transceiver channel ID." + ::= { ifRadio 2 } + +rxFreq OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Receiver frequency in kHz." + ::= { ifRadio 3 } + +txFreq OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Transceiver frequency in kHz." + ::= { ifRadio 4 } + +rxModulation OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Rx modulation text ID." + ::= { ifRadio 5 } + +txModulation OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Tx modulation text ID." + ::= { ifRadio 6 } + +rxModulationIndex OBJECT-TYPE + SYNTAX ModulationList + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Rx modulation index." + ::= { ifRadio 7 } + +txModulationIndex OBJECT-TYPE + SYNTAX ModulationList + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Tx modulation index." + ::= { ifRadio 8 } + +bandwidth OBJECT-TYPE + SYNTAX INTEGER { + na (0), + bw-28MHz (1), + bw-14MHz (2), + bw-7MHz (3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Radio channel bandwidth. Supported by RAy10 only." + ::= { ifRadio 9 } + +coding OBJECT-TYPE + SYNTAX INTEGER { + na (0), + low (1), + hi (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel coding level. Supported by RAy10 only." + ::= { ifRadio 10 } + +matching OBJECT-TYPE + SYNTAX OptionSetting + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel matching." + ::= { ifRadio 11 } + +rfPowerConfigured OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Configured RF Power in dBm." + ::= { ifRadio 12 } + +netBitrate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current net bitrate in kbps." + ::= { ifRadio 13 } + +maxNetBitrate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Maximum net bitrate in Mbps." + ::= { ifRadio 14 } + +bandwidthKHz OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Radio channel bandwidth in kHz. Not supported by RAy10." + ::= { ifRadio 15 } + +channelArrangement OBJECT-TYPE + SYNTAX INTEGER { + na (0), + accp (1), + acap (2), + ccdp (3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel arrangement. Not supported by RAy10." + ::= { ifRadio 16 } + +rfPowerCurrent OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current RF Power in dBm. Not supported by RAy10." + ::= { ifRadio 17 } + +-- ifEth mib + +ifEthTable OBJECT-TYPE + SYNTAX SEQUENCE OF IfEthEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "List of Ethernet interfaces." + ::= { ifEth 1 } + +ifEthEntry OBJECT-TYPE + SYNTAX IfEthEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Ethernet interface entry." + INDEX { speed } + ::= { ifEthTable 1 } + +IfEthEntry ::= + SEQUENCE { + speed Integer32, + duplex INTEGER, + mdix INTEGER, + autonego OptionSetting, + pause OptionSetting, + asymPause OptionSetting + } + +speed OBJECT-TYPE + SYNTAX Integer32(1..1000000000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Ethernet speed." + ::= { ifEthEntry 1 } +duplex OBJECT-TYPE + SYNTAX INTEGER { + na (0), + full (1), + half (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Ethernet duplex." + ::= { ifEthEntry 2 } + +mdix OBJECT-TYPE + SYNTAX INTEGER { + na (0), + mdi (1), + mdi-x (2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Ethernet MDI-X / MDI." + ::= { ifEthEntry 3 } + +autonego OBJECT-TYPE + SYNTAX OptionSetting + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Ethernet autonego." + ::= { ifEthEntry 4 } + +pause OBJECT-TYPE + SYNTAX OptionSetting + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Ethernet pause." + ::= { ifEthEntry 5 } + +asymPause OBJECT-TYPE + SYNTAX OptionSetting + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Ethernet asymmetric pause." + ::= { ifEthEntry 6 } + +prioritized OBJECT-TYPE + SYNTAX OptionSetting + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Ethernet prioritized VLAN support. Supported by RAy10 only." + ::= { ifEth 2 } + +vlanId OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Ethernet prioritized VLAN ID. Supported by RAy10 only." + ::= { ifEth 3 } + +serviceVlanId OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Ethernet service VLAN ID between local and remote station. Not supported by RAy2." + ::= { ifEth 4 } + + +-- statistic mib +modemR OBJECT IDENTIFIER ::= {statistic 1} +radio OBJECT IDENTIFIER ::= {statistic 2} +ethernet OBJECT IDENTIFIER ::= {statistic 3} + + -- statistic radiomodem ethernet mib +rxPauseFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of received Control frames with a valid PAUSE op-code. Supported by RAy10 only." + ::= { modemR 1 } + +rxControlFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of received Control frames. Supported by RAy10 only." + ::= { modemR 2 } + +rxBroadcast OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of received packets with a broadcast destination address. Supported by RAy10 only." + ::= { modemR 3 } + +rxMulticast OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of received packets with a multicast destination address. Supported by RAy10 only." + ::= { modemR 4 } + +rxDones OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of successfully received packets. Supported by RAy10 only." + ::= { modemR 5 } + +rxOutOfRangeErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of received frames larger than 1518 bytes (the frame Type/Length field is indicating a value larger than 1518 bytes). Supported by RAy10 only." + ::= { modemR 6 } + +rxCrcErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of received frames with the CRC which does not match the internally generated CRC. Supported by RAy10 only." + ::= { modemR 7 } + +rxCodeErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of received packets with one or more erroneous nibbles. Supported by RAy10 only." + ::= { modemR 8 } + +rxFalseCarrierErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Rx false carrier errors. Supported by RAy10 only." + ::= { modemR 9 } + +rxDroppedPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of dropped packets. Supported by RAy10 only." + ::= { modemR 10 } + +rxHCBytes OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of received bytes. Supported by RAy10 only." + ::= { modemR 11 } + +txPauseFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of transmitted Control frames with a valid PAUSE op-code. Supported by RAy10 only." + ::= { modemR 12 } + +txControlFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of transmitted Control frames. Supported by RAy10 only." + ::= { modemR 13 } + +txBroadcast OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of transmitted packets with a broadcast destination address. Supported by RAy10 only." + ::= { modemR 14 } + +txMulticast OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of transmitted packets with a multicast destination address. Supported by RAy10 only." + ::= { modemR 15 } + +txDones OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of successfully transmitted packets. Supported by RAy10 only." + ::= { modemR 16 } + +txLengthCheckErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of transmitted packets with the frame Length field (not a Type field) value that does not match the actual data byte length. Supported by RAy10 only." + ::= { modemR 17 } + +txCrcErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of transmitted frames with the CRC which does not match the internally generated CRC. Supported by RAy10 only." + ::= { modemR 18 } + +txCollisions OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Tx collisions. Supported by RAy10 only." + ::= { modemR 19 } + +txHCBytes OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of transmitted bytes. Supported by RAy10 only." + ::= { modemR 20 } + +-- statistic radio mib + +rss OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Receiving RSS indicator in decimal dBm (-39 -> -3,9)." + ::= { radio 1 } + +snr OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Receiving SNR indicator in decimal dB (39 -> 3,9)." + ::= { radio 2 } + +fecBlockCounter OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Total block counter for BER calculation. Block size is 2048 bits. Supported by RAy10 only." + ::= { radio 3 } + +fecUncorrectBlockCounter OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Incorrect block counter for BER calculation. Block size is 2048 bits. Supported by RAy10 only." + ::= { radio 4 } + +timeAllConnect OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overall link uptime." + ::= { radio 5 } + +timeAllDisconnect OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Overall link downtime." + ::= { radio 6 } + +timeMaxDisconnect OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The longest drop (disconnecting)." + ::= { radio 7 } + +numDisconnect OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of drops (disconnecting)." + ::= { radio 8 } + +reliability OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Reliability in thousandths of %." + ::= { radio 9 } + +linkUptime OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current radio link uptime. Not supported by RAy10." + ::= { radio 10 } + +ber OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Bit Error Rate (BER) multiplied by 10^9. Not supported by RAy10." + ::= { radio 11 } + +-- statistic Ethernet mib + +ethInThroughput OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Input Ethernet 1 data port throughput in kbps. Not supported by RAy10." + ::= { ethernet 1 } + +ethOutThroughput OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Output Ethernet 1 data port throughput in kbps. Not supported by RAy10." + ::= { ethernet 2 } + +eth2InThroughput OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Input Ethernet 2 data port throughput in kbps. Supported by RAy2 only." + ::= { ethernet 3 } + +eth2OutThroughput OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Output Ethernet 2 data port throughput in kbps. Supported by RAy2 only." + ::= { ethernet 4 } + + +-- definition traps + +airDisconnect NOTIFICATION-TYPE + OBJECTS { lineStatus } + STATUS current + DESCRIPTION + "Air line disconnected. Not supported by RAy2." + ::= { rayTraps 1 } + +airConnect NOTIFICATION-TYPE + OBJECTS { lineStatus } + STATUS current + DESCRIPTION + "Air line connected after being disconnected. Not supported by RAy2." + ::= { rayTraps 2 } + +airWdog NOTIFICATION-TYPE + OBJECTS { lineStatus } + STATUS current + DESCRIPTION + "Air watch dog. Supported by RAy10 only." + ::= { rayTraps 3 } + +tempAlarm NOTIFICATION-TYPE + OBJECTS { temperatureModem } + STATUS current + DESCRIPTION + "Temperature exceeded the threshold. Not supported by RAy2." + ::= { rayTraps 4 } + +powerAlarm NOTIFICATION-TYPE + OBJECTS { voltageUnit } + STATUS current + DESCRIPTION + "Power voltage is out of the thresholds. Not supported by RAy2." + ::= { rayTraps 5 } + +memoryAlarm NOTIFICATION-TYPE + OBJECTS { useMemory } + STATUS current + DESCRIPTION + "Memory use exceeded the threshold. Supported by RAy10 only." + ::= { rayTraps 6 } + +rssAlarm NOTIFICATION-TYPE + OBJECTS { rss } + STATUS current + DESCRIPTION + "RSS exceeded the threshold. Not supported by RAy2." + ::= { rayTraps 7 } + +snrAlarm NOTIFICATION-TYPE + OBJECTS { snr } + STATUS current + DESCRIPTION + "SNR exceeded the threshold. Not supported by RAy2." + ::= { rayTraps 8 } + +berAlarm NOTIFICATION-TYPE + OBJECTS { fecUncorrectBlockCounter, fecBlockCounter } + STATUS current + DESCRIPTION + "BER exceeded the threshold. Not supported by RAy2." + ::= { rayTraps 9 } + +rfPowerFail NOTIFICATION-TYPE + OBJECTS { rfPowerStatus } + STATUS current + DESCRIPTION + "RF Power amplifier failure. Not supported." + ::= { rayTraps 10 } + +peerEthLinkDown NOTIFICATION-TYPE + OBJECTS { ethPeer } + STATUS current + DESCRIPTION + "Peer station Ethernet link Up/Down. Not supported by RAy2." + ::= { rayTraps 11 } + + +-- RAy2 trap definitions + +tr2TemperatureAlarm NOTIFICATION-TYPE + OBJECTS { temperatureModem, + alarmTemperature } + STATUS current + DESCRIPTION + "Temperature exceeded the threshold. Supported by RAy2 only." + ::= { ray2Traps 1 } + +tr2VoltageLowAlarm NOTIFICATION-TYPE + OBJECTS { voltageUnit, + alarmVoltageLow } + STATUS current + DESCRIPTION + "Supply voltage below minimal threshold. Supported by RAy2 only." + ::= { ray2Traps 2 } + +tr2VoltageHighAlarm NOTIFICATION-TYPE + OBJECTS { voltageUnit, + alarmVoltageHigh } + STATUS current + DESCRIPTION + "Supply voltage above maximal threshold. Supported by RAy2 only." + ::= { ray2Traps 3 } + +tr2RssAlarm NOTIFICATION-TYPE + OBJECTS { rss, + alarmRss } + STATUS current + DESCRIPTION + "RSS exceeded the threshold. Supported by RAy2 only." + ::= { ray2Traps 4 } + +tr2SnrAlarm NOTIFICATION-TYPE + OBJECTS { snr, + alarmSnr } + STATUS current + DESCRIPTION + "SNR exceeded the threshold. Supported by RAy2 only." + ::= { ray2Traps 5 } + +tr2BerAlarm NOTIFICATION-TYPE + OBJECTS { ber, + alarmBer } + STATUS current + DESCRIPTION + "BER exceeded the threshold. Supported by RAy2 only." + ::= { ray2Traps 6 } + +tr2AirDisconnect NOTIFICATION-TYPE + OBJECTS { lineStatusII, + alarmPeerDisconnected } + STATUS current + DESCRIPTION + "Air line disconnected. Supported by RAy2 only." + ::= { ray2Traps 7 } + +tr2AirConnect NOTIFICATION-TYPE + OBJECTS { lineStatusII, + alarmPeerDisconnected } + STATUS current + DESCRIPTION + "Air line connected after being disconnected. Supported by RAy2 (up to fw 2.1.7.0) only." + ::= { ray2Traps 8 } + +tr2Eth1LinkDown NOTIFICATION-TYPE + OBJECTS { eth1Link, + alarmEth1Down } + STATUS current + DESCRIPTION + "Local station Ethernet 1 link Up/Down. Supported by RAy2 only." + ::= { ray2Traps 9 } + +tr2Eth21LinkDown NOTIFICATION-TYPE + OBJECTS { eth2Link, + alarmEth2Down } + STATUS current + DESCRIPTION + "Local station Ethernet 2 link Up/Down. Supported by RAy2 only." + ::= { ray2Traps 10 } + +tr2RfPowerFail NOTIFICATION-TYPE + OBJECTS { rfPowerStatus, + alarmRfPowerFail } + STATUS current + DESCRIPTION + "RF Power amplifier failure. Supported by RAy2 only." + ::= { ray2Traps 11 } + +tr2NetBitrate NOTIFICATION-TYPE + OBJECTS { netBitrate, + alarmNetBitrate } + STATUS current + DESCRIPTION + "Air speed below threshold. Supported by RAy2 only." + ::= { ray2Traps 12 } + +tr2WifiOn NOTIFICATION-TYPE + OBJECTS { wifiHAP, + alarmWifiOn } + STATUS current + DESCRIPTION + "WiFi Host Access Point is on. Supported by RAy2 only." + ::= { ray2Traps 13 } + +END -- cgit v1.2.3