From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/transition/TN-ELPS-MIB | 586 ++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 586 insertions(+) create mode 100644 MIBS/transition/TN-ELPS-MIB (limited to 'MIBS/transition/TN-ELPS-MIB') diff --git a/MIBS/transition/TN-ELPS-MIB b/MIBS/transition/TN-ELPS-MIB new file mode 100644 index 0000000..fb2375a --- /dev/null +++ b/MIBS/transition/TN-ELPS-MIB @@ -0,0 +1,586 @@ +-- ***************************************************************** +-- TN-ELPS-MIB.my : TN Ethernet Linear Protection Switch MIB +-- +-- Author : Angela Xing +-- update by Tony Lei +-- Copyright (c) 2009 by Transition Networks, Inc. +-- All rights reserved. +-- +-- ************************************************************************************************* +-- + +TN-ELPS-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, + NOTIFICATION-TYPE, + OBJECT-TYPE, + Unsigned32, + Gauge32 + FROM SNMPv2-SMI + MODULE-COMPLIANCE, + OBJECT-GROUP, + NOTIFICATION-GROUP + FROM SNMPv2-CONF + RowStatus,TruthValue, + MacAddress + FROM SNMPv2-TC -- [RFC2579] + InterfaceIndex + FROM IF-MIB + Dot1agCfmMepId + FROM IEEE8021-CFM-MIB + tnProducts + FROM TRANSITION-SMI + tnProtectionMIB + FROM TN-PROTECTION-MIB; + +-- +-- main body +-- +tnElpsMib OBJECT IDENTIFIER ::= { tnProtectionMIB 2 } + +tnElpsMibNotifications OBJECT IDENTIFIER ::= { tnElpsMib 0 } +tnElpsMibObjects OBJECT IDENTIFIER ::= { tnElpsMib 1 } +tnElpsMibConformance OBJECT IDENTIFIER ::= { tnElpsMib 2 } +-- +-- sub Objects list +-- +tnElpsCfgMgmt OBJECT IDENTIFIER ::= { tnElpsMibObjects 1 } +tnElpsStateMgmt OBJECT IDENTIFIER ::= { tnElpsMibObjects 2 } +tnElpsLinkOverMgmt OBJECT IDENTIFIER ::= { tnElpsMibObjects 3 } + +-- Textual Conventions +TnElpsProtSwitchState ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Indicates ELPS protection switch state." + SYNTAX INTEGER { + disabled (1), + noRequestW (2), + noRequestP (3), + lockout (4), + forcedSwitch (5), + signalFailW (6), + signalFailP (7), + manualSwitchW (8), + manualSwitchP (9), + waitToRestore (10), + exerciseW (11), + exerciseP (12), + reverseRequestW (13), + reverseRequestP (14), + doNotRevert (15) + } + +TnElpsDefectState ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Indicates ELPS working/protecting state." + SYNTAX INTEGER { + signalOk (1), + signalFail (2), + signalDegrade (3) + } + +TnElpsRequestType ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Indicates ELPS received/transmitted APS request type." + SYNTAX INTEGER { + noRequest (1), + doNotRevert (2), + reverseRequest (3), + exercise (4), + wait2Restore (5), + manualSwitch (6), + signalDegrade (7), + signalFailForWorking (8), + forcedWwitch (9), + signalFailForProtection (10), + lockoutOfProtection (11) + } + +-- ****************************************************************** +-- NOTIFICATIONS (TRAPS) +-- These notifications will be sent to the management entity +-- whenever a MEP loses/restores contact with one or more other MEPs. +-- ****************************************************************** + +tnElpsAlarmUp NOTIFICATION-TYPE + OBJECTS { tnElpsProtectionState, + tnElpsWFlowState, + tnElpsPFlowState, + tnElpsArchitectureMismatch, + tnElpsAPSOnWorking, + tnElpsSwitchingIncomplete + } + STATUS current + DESCRIPTION + "A Elps has a persistent defect condition. A notification + (fault alarm) is sent to the management entity with the OID + of the Elps that has detected the fault. + + The management entity receiving the notification can identify + the system from the network source address of the + notification, and can identify the ELPS reporting the defect + by the indices in the OID of the variables in the notification: + + tnElpsInstance - Also the index of the EPLS state table entry + (tnElpsStateTable). + " + ::= { tnElpsMibNotifications 1 } + +tnElpsAlarmDown NOTIFICATION-TYPE + OBJECTS { tnElpsProtectionState, + tnElpsWFlowState, + tnElpsPFlowState, + tnElpsArchitectureMismatch, + tnElpsAPSOnWorking, + tnElpsSwitchingIncomplete + } + STATUS current + DESCRIPTION + "A Elps has a persistent defect condition. A notification + (fault alarm) is sent to the management entity with the OID + of the Elps that has detected the fault. + + The management entity receiving the notification can identify + the system from the network source address of the + notification, and can identify the ELPS reporting the defect + by the indices in the OID of the variables in the notification: + + tnElpsInstance - Also the index of the EPLS state table entry + (tnElpsStateTable). + " + ::= { tnElpsMibNotifications 2 } + + +-- ****************************************************************** +-- TN Elps Cfg Table +-- ****************************************************************** +tnElpsCfgTable OBJECT-TYPE + SYNTAX SEQUENCE OF TnElpsCfgEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table provides configuration of ELPS." + ::= { tnElpsCfgMgmt 1 } + +tnElpsCfgEntry OBJECT-TYPE + SYNTAX TnElpsCfgEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A entry in the table represents a configuration for ELPS." + INDEX { tnElpsInstance } + ::= { tnElpsCfgTable 1 } + +TnElpsCfgEntry ::= + SEQUENCE{ + tnElpsInstance Unsigned32, + tnElpsDomain INTEGER, + tnElpsArchitecture INTEGER, + tnElpsWFlowPortId InterfaceIndex, + tnElpsPFlowPortId InterfaceIndex, + tnElpsWSfMepId Dot1agCfmMepId, + tnElpsPSfMepId Dot1agCfmMepId, + tnElpsApsMepId Dot1agCfmMepId, + tnElpsConfigured TruthValue, + tnElpsDirection INTEGER, + tnElpsApsEnable TruthValue, + tnElpsRevertiveEnable TruthValue, + tnElpsWTRTime INTEGER, + tnElpsHoldOffTime INTEGER, + tnElpsCmd INTEGER, + tnElpsStatus RowStatus + } + +tnElpsInstance OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The ID of the ELPS." + ::= { tnElpsCfgEntry 1 } + +tnElpsDomain OBJECT-TYPE + SYNTAX INTEGER { + port (1) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Port: This will create a ELPS in the Port Domain. 'W/P Flow' is a Port." + ::= { tnElpsCfgEntry 2} + +tnElpsArchitecture OBJECT-TYPE + SYNTAX INTEGER{ + onePlusOne (1), + oneForOne (2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Port: This will create a 1+1 ELPS. + Port: This will create a 1:1 ELPS." + ::= { tnElpsCfgEntry 3} + +tnElpsWFlowPortId OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The working flow for the ELPS - See 'Domain' above." + ::= { tnElpsCfgEntry 4} + +tnElpsPFlowPortId OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The protecting flow for the ELPS - See 'Domain' above." + ::= { tnElpsCfgEntry 5} + +tnElpsWSfMepId OBJECT-TYPE + SYNTAX Dot1agCfmMepId + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The working Signal Fail reporting MEP." + ::= { tnElpsCfgEntry 6} + +tnElpsPSfMepId OBJECT-TYPE + SYNTAX Dot1agCfmMepId + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The protecting Signal Fail reporting MEP." + ::= { tnElpsCfgEntry 7} + +tnElpsApsMepId OBJECT-TYPE + SYNTAX Dot1agCfmMepId + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The APS PDU handling MEP." + ::= { tnElpsCfgEntry 8} + +tnElpsConfigured OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "False: This ELPS is only created and has not yet been configured - is not active. + True: This ELPS is configured - is active." + ::= { tnElpsCfgEntry 9 } + +tnElpsDirection OBJECT-TYPE + SYNTAX INTEGER{ + unidirectional (1), + bidirectional (2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Unidirectional: ELPS in the two ends can select traffic from different + working/protecting flow. This is only possible in case + of 1+1. + Bidirectional: ELPS in the two ends is selecting traffic from the same + working/protecting flow. This requires APS enabled. + This is mandatory for 1:1." + ::= { tnElpsCfgEntry 10 } + +tnElpsApsEnable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The Automatic Protection Switching protocol can be enabled/disabled. This is mandatory for 1:1. + " + ::= { tnElpsCfgEntry 11 } + +tnElpsRevertiveEnable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The revertive switching to working flow can be enabled/disabled. + " + ::= { tnElpsCfgEntry 12 } + +tnElpsWTRTime OBJECT-TYPE + SYNTAX INTEGER{ + disabled (0), + t10sec (1), + t30sec (2), + t5min (3), + t6min (4), + t7min (5), + t8min (6), + t9min (7), + t10min (8), + t11min (9), + t12min (10) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The Wait To Restore timing value to be used in revertive switching. + " + ::= { tnElpsCfgEntry 13 } + +tnElpsHoldOffTime OBJECT-TYPE + SYNTAX INTEGER{ + disabled (0), + t100ms (1), + t200ms (2), + t300ms (3), + t400ms (4), + t500ms (5), + t600ms (6), + t700ms (7), + t800ms (8), + t900ms (9), + t1s (10), + t2s (11), + t3s (12), + t4s (13), + t5s (14), + t6s (15), + t7s (16), + t8s (17), + t9s (18), + t10s (19) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The timing value to be used to make persistent check on Signal Fail before switching. + " + ::= { tnElpsCfgEntry 14 } + +tnElpsCmd OBJECT-TYPE + SYNTAX INTEGER{ + none (0), + clear (1), + lockOut (2), + forcedSwitch (3), + manualSwitchP (4), + manualSwitchW (5), + exercise (6), + freeze (7), + lockOutLocal (8) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "None: There is no active local command on this instance. + Clear: The active local command will be cleared. + Lock Out: This ELPS is locked to working (not active). In case of 1:N (more than one ELPS with same protecting flow) - + when one ELPS switch to protecting flow, other ELPS is enforced this command + Forced Switch: Forced switch to protecting. + Manual Switch P: Manual switch to protecting. + Manual Switch W: Manual switch to working - this is only possible in 1:1 non-revertive. + Exercise: Exercise of the protocol - not traffic effecting. + Freeze: This ELPS is locally freezed - ignoring all input. + Lock Out Local: This ELPS is locally 'locked out' - ignoring local SF detected on working." + ::= { tnElpsCfgEntry 15 } + +tnElpsStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The status of the row. + The writable columns in a row can not be changed if the row + is active. All columns must have a valid value before a row + can be activated." + ::= { tnElpsCfgEntry 16 } +-- ****************************************************************** +-- TN Elps state table +-- ****************************************************************** +tnElpsStateTable OBJECT-TYPE + SYNTAX SEQUENCE OF TnElpsStateEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table provides configuration about ELPS state" + ::= { tnElpsStateMgmt 1 } + +tnElpsStateEntry OBJECT-TYPE + SYNTAX TnElpsStateEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This entry represents configuration about ELPS state" + INDEX { tnElpsInstance } + ::= { tnElpsStateTable 1 } + +TnElpsStateEntry ::= SEQUENCE{ + tnElpsProtectionState TnElpsProtSwitchState, + tnElpsWFlowState TnElpsDefectState, + tnElpsPFlowState TnElpsDefectState, + tnElpsTransmitRequestType TnElpsRequestType, + tnElpsTransmitRequestedSignal Unsigned32, + tnElpsTransmitBridgedSignal Unsigned32, + tnElpsReceiveRequestType TnElpsRequestType, + tnElpsReceiveRequestedSignal Unsigned32, + tnElpsReceiveBridgedSignal Unsigned32, + tnElpsArchitectureMismatch TruthValue, + tnElpsAPSOnWorking TruthValue, + tnElpsSwitchingIncomplete TruthValue, + tnElpsNoApsReceived TruthValue + } + +tnElpsProtectionState OBJECT-TYPE + SYNTAX TnElpsProtSwitchState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "ELPS Protection state" + ::= { tnElpsStateEntry 1} + +tnElpsWFlowState OBJECT-TYPE + SYNTAX TnElpsDefectState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "signalOk: State of working flow is ok + signalFail: State of working flow is Signal Fail + signalDegrade: State of working flow is Signal Degrade (for future use)" + ::= { tnElpsStateEntry 2} + +tnElpsPFlowState OBJECT-TYPE + SYNTAX TnElpsDefectState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "signalOk: State of protecting flow is ok + signalFail: State of protecting flow is Signal Fail + signalDegrade: State of protecting flow is Signal Degrade (for future use)" + ::= { tnElpsStateEntry 3} + +tnElpsTransmitRequestType OBJECT-TYPE + SYNTAX TnElpsRequestType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The transmitted request type." + ::= { tnElpsStateEntry 4} + +tnElpsTransmitRequestedSignal OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The transmitted request signal." + ::= { tnElpsStateEntry 5} + +tnElpsTransmitBridgedSignal OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The transmitted bridged signal." + ::= { tnElpsStateEntry 6} + +tnElpsReceiveRequestType OBJECT-TYPE + SYNTAX TnElpsRequestType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The requested type that is received from APS." + ::= { tnElpsStateEntry 7} + +tnElpsReceiveRequestedSignal OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The requested signal received from APS." + ::= { tnElpsStateEntry 8} + +tnElpsReceiveBridgedSignal OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The bridged signal received from APS ." + ::= { tnElpsStateEntry 9} + +tnElpsArchitectureMismatch OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The architecture indicated in the received APS does not match the locally configured." + ::= { tnElpsStateEntry 10} + +tnElpsAPSOnWorking OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "APS is received on the working flow." + ::= { tnElpsStateEntry 11} + +tnElpsSwitchingIncomplete OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Traffic is not selected from the same flow instance in the two ends." + ::= { tnElpsStateEntry 12} + +tnElpsNoApsReceived OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "APS PDU is not received from the other end." + ::= { tnElpsStateEntry 13} + +-- ****************************************************************** +-- TN Elps LinkOver table +-- ****************************************************************** +tnElpsLinkOverTable OBJECT-TYPE + SYNTAX SEQUENCE OF TnElpsLinkOverEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table provides configuration about ELPS Link Over based on the SOAM DM" + ::= { tnElpsLinkOverMgmt 1 } + +tnElpsLinkOverEntry OBJECT-TYPE + SYNTAX TnElpsLinkOverEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This entry represents configuration about ELPS Link Over" + INDEX { tnElpsInstance } + ::= { tnElpsLinkOverTable 1 } + +TnElpsLinkOverEntry ::= SEQUENCE{ + tnElpsLinkOverEnabled TruthValue, + tnElpsLinkOverDeltaValue Unsigned32 +} + +tnElpsLinkOverEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The feature about the DM LinkOver can be enabled and disabeld. + False: This feature is disabled. + True: This ELPS is enabled." + ::= { tnElpsLinkOverEntry 1 } + +tnElpsLinkOverDeltaValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Delta value is ranged from 6 to 120. If the value that is on one link subtract the other one is + larger than the delta value, the data flow will be swithed to the link that own the better DM value." + ::= { tnElpsLinkOverEntry 2 } +END -- cgit v1.2.3