From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/wut/WebGraph-Thermo-Hygrometer-MIB | 2215 +++++++++++++++++++++++++++++++ 1 file changed, 2215 insertions(+) create mode 100644 MIBS/wut/WebGraph-Thermo-Hygrometer-MIB (limited to 'MIBS/wut/WebGraph-Thermo-Hygrometer-MIB') diff --git a/MIBS/wut/WebGraph-Thermo-Hygrometer-MIB b/MIBS/wut/WebGraph-Thermo-Hygrometer-MIB new file mode 100644 index 0000000..c0bb453 --- /dev/null +++ b/MIBS/wut/WebGraph-Thermo-Hygrometer-MIB @@ -0,0 +1,2215 @@ +WebGraph-Thermo-Hygrometer-MIB DEFINITIONS ::= BEGIN +---------------------------------------------------------------- +-- Revison: 1.26 +---------------------------------------------------------------- +-- 03.08.2006 wtWebGraphThermHygroSensorNo korrigiert +-- +---------------------------------------------------------------- +-- Revison: 1.25 +---------------------------------------------------------------- +-- 28.06.2006 New: Community String Trap +-- +---------------------------------------------------------------- +-- Revison: 1.24 +---------------------------------------------------------------- +-- 26.07.2005 #57606, WebGraph Thermo-Hygrometer +-- CRON Zeitfunktion +---------------------------------------------------------------- +-- Revison: 1.23 +---------------------------------------------------------------- +-- 14.07.2005 #57606, WebGraph Thermo-Hygrometer +-- FTP Funktionen +---------------------------------------------------------------- +-- Revison: 1.22 +---------------------------------------------------------------- +-- 17.05.2005 #57606, WebGraph Thermo-Hygrometer +-- Trap NMS annotations +---------------------------------------------------------------- +-- Revison: 1.21 +---------------------------------------------------------------- +-- 19.04.2005 #57606, WebGraph Thermo-Hygrometer +-- Mail Authentication +---------------------------------------------------------------- +-- Revison: 1.20 +---------------------------------------------------------------- +-- 05.11.2004 #57606, WebGraph Themo-Hygrometer +-- Neu: Syslog +-- +---------------------------------------------------------------- +-- Revison: 1.19 +---------------------------------------------------------------- +-- 08.09.2004 #57606 WebGraph Thermo-Hygrometer +-- Neu: +-- wtWebGraphThermHygroAlarmRHMin +-- wtWebGraphThermHygroAlarmRHMax +-- wtWebGraphThermHygroAlarmRHHysteresis +-- wtWebGraphThermHygroPortSensorSelect +-- wtWebGraphThermHygroAlarmDeltaTemp +-- wtWebGraphThermHygroAlarmAHMin +-- wtWebGraphThermHygroAlarmAHMax +---------------------------------------------------------------- +-- Revison: 1.18 +---------------------------------------------------------------- +-- 21.07.2004 #57601/3/4, Webio Digital +-- Neu: +-- Diagnosis +---------------------------------------------------------------- +-- Revison: 1.17 +---------------------------------------------------------------- +-- 28.06.2004 #57630/1/2, Webio Digital +-- Neu: Puls Mode +---------------------------------------------------------------- +-- Revison: 1.16 +---------------------------------------------------------------- +-- 16.04.2004 neu: #57632, Webio Digital EA24x24 +-- +-- #57630/1, Webio Digital EA12x12 +-- Neu: +-- wtWebioEA12x12InputCounterClear +---------------------------------------------------------------- +-- Revison: 1.15 +---------------------------------------------------------------- +-- 27.02.2004 #57630/1, Webio Digital EA12x12 +-- Neu: +-- Länge erweitert auf 32 Bit: +-- wtWebioEA12x12InputValue +-- wtWebioEA12x12OutputValue +-- wtWebioEA12x12LoadControlView +-- wtWebioEA12x12LCShutDownView +-- wtWebioEA12x12SetOutput +-- wtWebioEA12x12AlarmInputTrigger +-- wtWebioEA12x12AlarmOutputTrigger +-- wtWebioEA12x12PortOutputSafetyState +---------------------------------------------------------------- +-- Revison: 1.14 +---------------------------------------------------------------- +-- 16.02.2004 #57630/1, Webio Digital EA12x12 +-- Neu: +-- Texte: Location, Contact +-- SNMP: ColdStart, WarmStart, ComunityString Read/RW +-- Alarm: ColdStart / WarmStart trigger +-- +-- #57601, 1xWebThermometer +-- #57603, 2xWebThermometer +-- #57604, 8xWebThermometer +-- Neu: +-- Alarm Hysterese +-- Alarm Clear Traps und Mails +---------------------------------------------------------------- +-- Revison: 1.13 +---------------------------------------------------------------- +-- 05.02.2004 #57601, 1xWebThermometer +-- #57603, 2xWebThermometer +-- #57604, 8xWebThermometer +-- Neu: +-- Texte: Location, Contact +-- SNMP: ColdStart, WarmStart, ComunityString Read/RW +-- Alarm: ColdStart / WarmStart trigger +---------------------------------------------------------------- +-- Revison: 1.12 +---------------------------------------------------------------- +-- 05.11.2003 #57601, 1xWebThermometer +-- #57603, 2xWebThermometer +-- #57604, 8xWebThermometer +-- Neu: +-- Mail Option: CSV attachment +-- Offsetkalibrierung +-- Alarm: Tcp Client mode +---------------------------------------------------------------- +-- Revison: 1.11 +---------------------------------------------------------------- +-- 28.10.2003 #57630/1, Webio Digital EA12x12 +-- Neue Feature: +-- Alarm : TCP Client mode +-- INPUTS: Pulsfilter +---------------------------------------------------------------- +-- Revison: 1.10 +---------------------------------------------------------------- +-- 04.07.2003 #57630, Webio Digital EA12x12 +-- Neuer Menübaum, neue Binärmodi +-- +---------------------------------------------------------------- +-- Revison: 1.09 +---------------------------------------------------------------- +-- 24.03.2003 Trap Enterprise (Type 1, 2) korrigiert +-- +---------------------------------------------------------------- +-- Revison: 1.08 +---------------------------------------------------------------- +-- 04.03.2003 Abgleich der Sprachversionen DE/US +-- +---------------------------------------------------------------- +-- Revison: 1.07 +---------------------------------------------------------------- +-- 25.02.2003 Korrektur US: wtWebioEA12x12LoadControl +---------------------------------------------------------------- +-- Revison: 1.06 +---------------------------------------------------------------- +-- 24.02.2003 Neu: +-- #57630, Webio EA12x12, LoadControl Group +-- Korrektur: Trap variable Namen +---------------------------------------------------------------- +-- Revison: 1.05 +---------------------------------------------------------------- +-- 21.01.2003 Neu: +-- #57630, Webio EA12x12 +---------------------------------------------------------------- +-- Revison: 1.04 +---------------------------------------------------------------- +-- 02.01.2003 Neu: +-- #57601, 1xWebThermometer +-- #57603, 2xWebThermometer, 8 Alarme +---------------------------------------------------------------- +-- Revison: 1.03 +---------------------------------------------------------------- +-- 21.11.2002 Neu: +-- #57604, 2xWebThermometer, BOOTP, StartupSite +-- #57603, 8xWebThermometer, BOOTP, StartupSite +---------------------------------------------------------------- +-- Revison: 1.02 +---------------------------------------------------------------- +-- 26.07.2002 Neu: +-- #57604, 2xWebThermometer +-- #57603, 8xWebThermometer +-- + + IMPORTS + + OBJECT-TYPE FROM RFC-1212 + TRAP-TYPE FROM RFC-1215 + DisplayString, PhysAddress FROM RFC1213-MIB + enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI; + + +-- IpAddress ::= +-- [APPLICATION 0] +-- IMPLICIT OCTET STRING (SIZE (4)) +-- Counter ::= +-- [APPLICATION 1] +-- IMPLICIT INTEGER (0..4294967295) +-- Gauge ::= +-- [APPLICATION 2] +-- IMPLICIT INTEGER (0..4294967295) +-- TimeTicks ::= +-- [APPLICATION 3] +-- IMPLICIT INTEGER (0..4294967295) + + +-- DisplayString ::= OCTET STRING +-- PhysAddress ::= OCTET STRING + +-- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 } +-- privat OBJECT IDENTIFIER ::= { internet 4 } +-- enterprises OBJECT IDENTIFIER ::= { privat 1 } + + + +-- Wiesemann & Theis Com-Server MIB + + wut OBJECT IDENTIFIER ::= { enterprises 5040 } + wtComServer OBJECT IDENTIFIER ::= { wut 1 } + wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 } + + +-- wtWebGraph Tree + + wtWebGraphThermHygro OBJECT IDENTIFIER ::= { wtWebio 9 } + +-- wtWebGraphThermHygro Tree + + wtWebGraphThermHygroTemp OBJECT IDENTIFIER ::= { wtWebGraphThermHygro 1 } + wtWebGraphThermHygroSessCntrl OBJECT IDENTIFIER ::= { wtWebGraphThermHygro 2 } + wtWebGraphThermHygroConfig OBJECT IDENTIFIER ::= { wtWebGraphThermHygro 3 } + wtWebGraphThermHygroDiag OBJECT IDENTIFIER ::= { wtWebGraphThermHygro 4 } + +-- wtWebGraphThermHygroConfig Tree + + wtWebGraphThermHygroDevice OBJECT IDENTIFIER ::= { wtWebGraphThermHygroConfig 1 } + wtWebGraphThermHygroPorts OBJECT IDENTIFIER ::= { wtWebGraphThermHygroConfig 2 } + wtWebGraphThermHygroManufact OBJECT IDENTIFIER ::= { wtWebGraphThermHygroConfig 3 } + +-- wtWebGraphThermHygroDevice Tree + + wtWebGraphThermHygroText OBJECT IDENTIFIER ::= { wtWebGraphThermHygroDevice 1 } + wtWebGraphThermHygroTimeDate OBJECT IDENTIFIER ::= { wtWebGraphThermHygroDevice 2 } + wtWebGraphThermHygroBasic OBJECT IDENTIFIER ::= { wtWebGraphThermHygroDevice 3 } + wtWebGraphThermHygroDatalogger OBJECT IDENTIFIER ::= { wtWebGraphThermHygroDevice 4 } + wtWebGraphThermHygroAlarm OBJECT IDENTIFIER ::= { wtWebGraphThermHygroDevice 5 } + +-- wtWebGraphThermHygroTimeDate Tree + + wtWebGraphThermHygroTimeZone OBJECT IDENTIFIER ::= { wtWebGraphThermHygroTimeDate 1 } + wtWebGraphThermHygroTimeServer OBJECT IDENTIFIER ::= { wtWebGraphThermHygroTimeDate 2 } + wtWebGraphThermHygroDeviceClock OBJECT IDENTIFIER ::= { wtWebGraphThermHygroTimeDate 3 } + +-- wtWebGraphThermHygroBasic Tree + + wtWebGraphThermHygroNetwork OBJECT IDENTIFIER ::= { wtWebGraphThermHygroBasic 1 } + wtWebGraphThermHygroHTTP OBJECT IDENTIFIER ::= { wtWebGraphThermHygroBasic 2 } + wtWebGraphThermHygroMail OBJECT IDENTIFIER ::= { wtWebGraphThermHygroBasic 3 } + wtWebGraphThermHygroSNMP OBJECT IDENTIFIER ::= { wtWebGraphThermHygroBasic 4 } + wtWebGraphThermHygroUDP OBJECT IDENTIFIER ::= { wtWebGraphThermHygroBasic 5 } + wtWebGraphThermHygroSyslog OBJECT IDENTIFIER ::= { wtWebGraphThermHygroBasic 6 } + wtWebGraphThermHygroFTP OBJECT IDENTIFIER ::= { wtWebGraphThermHygroBasic 7 } + + + +-- wtWebGraphThermHygroTemp Group +------------------------ + +wtWebGraphThermHygroSensors OBJECT-TYPE + SYNTAX INTEGER (1..2) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Anzahl der Sensoren" + ::= { wtWebGraphThermHygroTemp 1 } + +-- Interface Table + +wtWebGraphThermHygroSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebGraphThermHygroSensorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste der Sensoren." + ::= { wtWebGraphThermHygroTemp 2 } + +wtWebGraphThermHygroSensorEntry OBJECT-TYPE + SYNTAX WtWebGraphThermHygroSensorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Nummern der Sensoren." + INDEX { wtWebGraphThermHygroSensorNo } + ::= { wtWebGraphThermHygroSensorTable 1 } + +WtWebGraphThermHygroSensorEntry ::= SEQUENCE { + wtWebGraphThermHygroSensorNo INTEGER +} + +wtWebGraphThermHygroSensorNo OBJECT-TYPE + SYNTAX INTEGER (1..2) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Nummer des Sensors." + ::= { wtWebGraphThermHygroSensorEntry 1 } + + +-- wtWebGraphThermHygroTempValue Table + +wtWebGraphThermHygroTempValueTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebGraphThermHygroTempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste Sensormesswerte korrespondiernd zu den Kanalnummern." + ::= { wtWebGraphThermHygroTemp 3 } + +wtWebGraphThermHygroTempValueEntry OBJECT-TYPE + SYNTAX WtWebGraphThermHygroTempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Messwerte der Sensoren." + INDEX { wtWebGraphThermHygroSensorNo } + ::= { wtWebGraphThermHygroTempValueTable 1 } + +WtWebGraphThermHygroTempValueEntry ::= SEQUENCE{ + wtWebGraphThermHygroTempValue OCTET STRING +} + +wtWebGraphThermHygroTempValue OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (5)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Messwert des Sensors, ASCII, 5 Zeichen lang." + ::= { wtWebGraphThermHygroTempValueEntry 1 } + +-- wtWebGraphThermHygroBinaryTempValue Table + +wtWebGraphThermHygroBinaryTempValueTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebGraphThermHygroBinaryTempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste binärer Messwerte korrespondiernd zu den Kanalnummern." + ::= { wtWebGraphThermHygroTemp 4 } + +wtWebGraphThermHygroBinaryTempValueEntry OBJECT-TYPE + SYNTAX WtWebGraphThermHygroBinaryTempValueEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Binäre Messwerte der Sensoren." + INDEX { wtWebGraphThermHygroSensorNo } + ::= { wtWebGraphThermHygroBinaryTempValueTable 1 } + +WtWebGraphThermHygroBinaryTempValueEntry ::= SEQUENCE{ + wtWebGraphThermHygroBinaryTempValue INTEGER +} + +wtWebGraphThermHygroBinaryTempValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Binärer Messwert des Sensors in 1/10 Grad Celcius oder 1/10 Prozent, + vorzeichenbehaftete Zahl, der Wert 0x4FFF6 zeigt einen + ungültigen Messwert an." + ::= { wtWebGraphThermHygroBinaryTempValueEntry 1 } + +-- wtWebGraphThermHygroSessCntrl Group +-------------------------------- + +wtWebGraphThermHygroSessCntrlPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Durch Eintrag diese Passworts wird eine Session eröffnet, die durch Schreiben einer 1 + in wtWebGraphThermHygroSessCntrlLogout beendet wird. Gelesen liefert diese Variable einen String der + Länge Null." + ::= { wtWebGraphThermHygroSessCntrl 1 } + +wtWebGraphThermHygroSessCntrlConfigMode OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermHygroSessCntrl-NoSession(0), + wtWebGraphThermHygroSessCntrl-Session(1) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Wenn sich das Gerät im SNMP-Konfigurationsmodus befindet, wird der Wert + 1 zurückgeliefert, ansonsten 0. Ist der ausgelesene Wert 0 + obwohl das Passwort geschrieben wurde, befindet sich das Gerät bereits + im Configmodus und die Variablen können nur gelesen werden." + ::= { wtWebGraphThermHygroSessCntrl 2 } + +wtWebGraphThermHygroSessCntrlLogout OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Wenn sich das Gerät im Konfigurationsmodus befindet und die Session wurde + von diesem SNMP Manager eröffnet, kann durch Schreiben einer 1 in diese + Variable die Session beendet werden und alle Parameter werden gespeichert. + Durch Schreiben einer 2 werden alle Eingaben wieder verworfen. + Gelesen liefert diese Variable den Wert 0." + ::= { wtWebGraphThermHygroSessCntrl 3 } + +wtWebGraphThermHygroSessCntrlAdminPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieses Passwort schützt den Zugang der Variablen mit Administratorrechten. Es kann nur vom + Administrator verändert werden. Wurde kein Passwort vergeben so ist public das gültige Passwort. + Gelesen liefert diese Variable einen Null-Pointer." + ::= { wtWebGraphThermHygroSessCntrl 4 } + +wtWebGraphThermHygroSessCntrlConfigPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieses Passwort schützt den Zugang der Variablen mit Configuratorrechten. Es kann vom + Administrator und vom Configurator verändert werden. Wurde kein Passwort vergeben so ist + public das gültige Passwort.Gelesen liefert diese Variable einen Null-Pointer." + ::= { wtWebGraphThermHygroSessCntrl 5 } + + +-- wtWebGraphThermHygroText Group +------------------------ + +wtWebGraphThermHygroDeviceName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name des Webio's, der userdefinierbar ist." + ::= { wtWebGraphThermHygroText 1 } + +wtWebGraphThermHygroDeviceText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Beschreibung des Webio's, die userdefinierbar ist." + ::= { wtWebGraphThermHygroText 2 } + +wtWebGraphThermHygroDeviceLocation OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Aufstellort des Webio's, die userdefinierbar ist." + ::= { wtWebGraphThermHygroText 3 } + +wtWebGraphThermHygroDeviceContact OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Kontaktadresse im Servicefall des Webio's, die userdefinierbar ist." + ::= { wtWebGraphThermHygroText 4 } + +-- wtWebGraphThermHygroTimeZone Group +---------------------------- + +wtWebGraphThermHygroTzOffsetHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset Stunden der Zeitzone (Winterzeit) in Bezug auf UTC." + ::= { wtWebGraphThermHygroTimeZone 1 } + +wtWebGraphThermHygroTzOffsetMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset Minuten der Zeitzone (Winterzeit) in Bezug auf UTC." + ::= { wtWebGraphThermHygroTimeZone 2 } + +wtWebGraphThermHygroTzEnable OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Bedingung: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 1-7: ungenutzt + Bit 0 : Apply Timezone" + ::= { wtWebGraphThermHygroTimeZone 3 } + +wtWebGraphThermHygroStTzOffsetHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset Stunden der Zeitzone (Sommerzeit) in Bezug auf UTC." + ::= { wtWebGraphThermHygroTimeZone 4 } + +wtWebGraphThermHygroStTzOffsetMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset Minuten der Zeitzone (Sommerzeit) in Bezug auf UTC." + ::= { wtWebGraphThermHygroTimeZone 5 } + +wtWebGraphThermHygroStTzEnable OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Bedingung: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 1-7: ungenutzt + Bit 0 : Apply Summertime" + ::= { wtWebGraphThermHygroTimeZone 6 } + +wtWebGraphThermHygroStTzStartMonth OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermHygroStartMonth-January(1), + wtWebGraphThermHygroStartMonth-February(2), + wtWebGraphThermHygroStartMonth-March(3), + wtWebGraphThermHygroStartMonth-April(4), + wtWebGraphThermHygroStartMonth-May(5), + wtWebGraphThermHygroStartMonth-June(6), + wtWebGraphThermHygroStartMonth-July(7), + wtWebGraphThermHygroStartMonth-August(8), + wtWebGraphThermHygroStartMonth-September(9), + wtWebGraphThermHygroStartMonth-October(10), + wtWebGraphThermHygroStartMonth-November(11), + wtWebGraphThermHygroStartMonth-December(12) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Monat, in dem von Winterzeit auf Sommerzeit umgestellt wird." + ::= { wtWebGraphThermHygroTimeZone 7 } + +wtWebGraphThermHygroStTzStartMode OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermHygroStartMode-first(1), + wtWebGraphThermHygroStartMode-second(2), + wtWebGraphThermHygroStartMode-third(3), + wtWebGraphThermHygroStartMode-fourth(4), + wtWebGraphThermHygroStartMode-last(5) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Modus des Wochentages, bei dem von Winterzeit auf Sommerzeit umgestellt wird." + ::= { wtWebGraphThermHygroTimeZone 8 } + +wtWebGraphThermHygroStTzStartWday OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermHygroStartWday-Sunday(1), + wtWebGraphThermHygroStartWday-Monday(2), + wtWebGraphThermHygroStartWday-Tuesday(3), + wtWebGraphThermHygroStartWday-Thursday(4), + wtWebGraphThermHygroStartWday-Wednesday(5), + wtWebGraphThermHygroStartWday-Friday(6), + wtWebGraphThermHygroStartWday-Saturday(7) + } + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Wochentag, bei dem von Winterzeit auf Sommerzeit umgestellt wird" + ::= { wtWebGraphThermHygroTimeZone 9 } + +wtWebGraphThermHygroStTzStartHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Stunde, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC + umgestellt wird." + ::= { wtWebGraphThermHygroTimeZone 10 } + +wtWebGraphThermHygroStTzStartMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minute, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC + umgestellt wird." + ::= { wtWebGraphThermHygroTimeZone 11 } + +wtWebGraphThermHygroStTzStopMonth OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermHygroStopMonth-January(1), + wtWebGraphThermHygroStopMonth-February(2), + wtWebGraphThermHygroStopMonth-March(3), + wtWebGraphThermHygroStopMonth-April(4), + wtWebGraphThermHygroStopMonth-May(5), + wtWebGraphThermHygroStopMonth-June(6), + wtWebGraphThermHygroStopMonth-July(7), + wtWebGraphThermHygroStopMonth-August(8), + wtWebGraphThermHygroStopMonth-September(9), + wtWebGraphThermHygroStopMonth-October(10), + wtWebGraphThermHygroStopMonth-November(11), + wtWebGraphThermHygroStopMonth-December(12) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Monat, bei dem von Sommerzeit auf Winterzeit umgestellt wird." + ::= { wtWebGraphThermHygroTimeZone 12 } + +wtWebGraphThermHygroStTzStopMode OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermHygroStopMode-first(1), + wtWebGraphThermHygroStopMode-second(2), + wtWebGraphThermHygroStopMode-third(3), + wtWebGraphThermHygroStopMode-fourth(4), + wtWebGraphThermHygroStopMode-last(5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Modus des Wochentages, bei dem von Sommerzeit auf Winterzeit umgestellt wird." + ::= { wtWebGraphThermHygroTimeZone 13 } + +wtWebGraphThermHygroStTzStopWday OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermHygroStopWday-Sunday(1), + wtWebGraphThermHygroStopWday-Monday(2), + wtWebGraphThermHygroStopWday-Tuesday(3), + wtWebGraphThermHygroStopWday-Thursday(4), + wtWebGraphThermHygroStopWday-Wednesday(5), + wtWebGraphThermHygroStopWday-Friday(6), + wtWebGraphThermHygroStopWday-Saturday(7) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Wochentage, bei dem von Sommerzeit auf Winterzeit umgestellt wird." + ::= { wtWebGraphThermHygroTimeZone 14 } + +wtWebGraphThermHygroStTzStopHrs OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Stunde, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC + umgestellt wird." + ::= { wtWebGraphThermHygroTimeZone 15 } + +wtWebGraphThermHygroStTzStopMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minute, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC + umgestellt wird." + ::= { wtWebGraphThermHygroTimeZone 16 } + +-- wtWebGraphThermHygroTimeServer Group +---------------------------- + +wtWebGraphThermHygroTimeServer1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse oder Name des 1. Time Servers in ASCII" + ::= { wtWebGraphThermHygroTimeServer 1 } + +wtWebGraphThermHygroTimeServer2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse oder Name des 2. Time Servers in ASCII" + ::= { wtWebGraphThermHygroTimeServer 2 } + +wtWebGraphThermHygroTsEnable OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Bedingung: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 1-7: ungenutzt + Bit 0 : Apply Time Server" + ::= { wtWebGraphThermHygroTimeServer 3 } + +wtWebGraphThermHygroTsSyncTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Die Abfrage der Timeserver erfolgt zu dieser vollen Stunde (0-23)." + ::= { wtWebGraphThermHygroTimeServer 4 } + +-- wtWebGraphThermHygroDeviceClock Group +---------------------------- + +wtWebGraphThermHygroClockHrs OBJECT-TYPE + SYNTAX INTEGER (0..23) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Uhrzeit Stunde, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebGraphThermHygroDeviceClock 1 } + +wtWebGraphThermHygroClockMin OBJECT-TYPE + SYNTAX INTEGER (0..59) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Uhrzeit Minute, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebGraphThermHygroDeviceClock 2 } + +wtWebGraphThermHygroClockDay OBJECT-TYPE + SYNTAX INTEGER (1..31) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Datum: Tag des Monats, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebGraphThermHygroDeviceClock 3 } + +wtWebGraphThermHygroClockMonth OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermHygroClockMonth-January(1), + wtWebGraphThermHygroClockMonth-February(2), + wtWebGraphThermHygroClockMonth-March(3), + wtWebGraphThermHygroClockMonth-April(4), + wtWebGraphThermHygroClockMonth-May(5), + wtWebGraphThermHygroClockMonth-June(6), + wtWebGraphThermHygroClockMonth-July(7), + wtWebGraphThermHygroClockMonth-August(8), + wtWebGraphThermHygroClockMonth-September(9), + wtWebGraphThermHygroClockMonth-October(10), + wtWebGraphThermHygroClockMonth-November(11), + wtWebGraphThermHygroClockMonth-December(12) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Datum: Monat, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebGraphThermHygroDeviceClock 4 } + +wtWebGraphThermHygroClockYear OBJECT-TYPE + SYNTAX INTEGER (0..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Datum: Jahr, unter Berücksichtigung der Zeitzoneneinstellungen." + ::= { wtWebGraphThermHygroDeviceClock 5 } + + +-- wtWebGraphThermHygroNetwork Group +------------------------ + +wtWebGraphThermHygroIpAddress OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse des Webio's" + ::= { wtWebGraphThermHygroNetwork 1 } + +wtWebGraphThermHygroSubnetMask OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Subnetmask des Webio's" + ::= { wtWebGraphThermHygroNetwork 2 } + +wtWebGraphThermHygroGateway OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Gateway des Webio's" + ::= { wtWebGraphThermHygroNetwork 3 } + +wtWebGraphThermHygroDnsServer1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse des 1. DNS Servers in ASCII" + ::= { wtWebGraphThermHygroNetwork 4 } + +wtWebGraphThermHygroDnsServer2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse des 2. DNS Servers in ASCII" + ::= { wtWebGraphThermHygroNetwork 5 } + +wtWebGraphThermHygroAddConfig OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Zusatzkonfiguration (1=EIN): + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: BOOTP disable + " + ::= { wtWebGraphThermHygroNetwork 6 } + +-- wtWebGraphThermHygroHTTP Group +-------------------------------- + +wtWebGraphThermHygroStartup OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Legt die Startseite fest, nur eine Auswahl zulässig: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 2: user.htm + Bit 1: home.htm + Bit 0: index.htm" + ::= { wtWebGraphThermHygroHTTP 1 } + +wtWebGraphThermHygroGetHeaderEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Wenn freigeschaltet, wird eine Erkennungssequenz nach + jeder GET-Anfrage der Antwort vorangestellt: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 1-7: ungenutzt + Bit 0 : GET Header enable" + ::= { wtWebGraphThermHygroHTTP 2 } + +wtWebGraphThermHygroHttpPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "HTTP Port, an den die TCP-Anfragen gesendet werden können (Default: 80)." + ::= { wtWebGraphThermHygroHTTP 3 } + +-- wtWebGraphThermHygroMail Group +-------------------------------- + +wtWebGraphThermHygroMailAdName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Gerätename für die Mail-Administration." + ::= { wtWebGraphThermHygroMail 1 } + +wtWebGraphThermHygroMailReply OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reply-Adresse für den Mailserver." + ::= { wtWebGraphThermHygroMail 2 } + +wtWebGraphThermHygroMailServer OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name oder Ip-Adresse des Mailservers." + ::= { wtWebGraphThermHygroMail 3 } + +wtWebGraphThermHygroMailEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Erlaubt das versenden von Mails: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 1-7: ungenutzt + Bit 0 : Mail enable" + ::= { wtWebGraphThermHygroMail 4 } + +wtWebGraphThermHygroMailAuthentication OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Auswahl des Authenticationmodi: + die OCTETS werden bitweise interpretiert, es darf nur ein Bit gesetzt sein. + Bit 0 entspricht dem LSB. + OCTET 1: ungenutzt + OCTET 2: ungenutzt + OCTET 3: ungenutzt + OCTET 4: Bit 3-7: ungenutzt + Bit 2 : POP3 vor SMTP + Bit 1 : ESMTP, Authentifizierung + Bit 0 : SMTP, keine Authentifizierung" + ::= { wtWebGraphThermHygroMail 5 } + +wtWebGraphThermHygroMailAuthUser OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name des Postfaches / Postfachusers." + ::= { wtWebGraphThermHygroMail 6 } + +wtWebGraphThermHygroMailAuthPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Passwort zur Identifizierung des Users." + ::= { wtWebGraphThermHygroMail 7 } + +wtWebGraphThermHygroMailPop3Server OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name oder Ip-Adresse des POP3 Servers." + ::= { wtWebGraphThermHygroMail 8 } + +-- wtWebGraphThermHygroSNMP Group +-------------------------------- + +wtWebGraphThermHygroSnmpCommunityStringRead OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Community string read only" + ::= { wtWebGraphThermHygroSNMP 1 } + +wtWebGraphThermHygroSnmpCommunityStringReadWrite OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Community string read / write" + ::= { wtWebGraphThermHygroSNMP 2 } + +wtWebGraphThermHygroSystemTrapManagerIP OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name oder IP-Adresse des SNMP-Managers, der den System Trap entgegen nimmt." + ::= { wtWebGraphThermHygroSNMP 3 } + +wtWebGraphThermHygroSystemTrapEnable OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Triggerbedingungen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: ColdStart + Bit 1: WarmStart + Bit 2-7: ungenutzt" + ::= { wtWebGraphThermHygroSNMP 4 } + +wtWebGraphThermHygroSnmpEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bit 0 schaltet SNMP frei: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 1-7: ungenutzt + Bit 0 : SNMP enable" + ::= { wtWebGraphThermHygroSNMP 5 } + +wtWebGraphThermHygroSnmpCommunityStringTrap OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Community string der Traps." + ::= { wtWebGraphThermHygroSNMP 6 } + + +-- wtWebGraphThermHygroUDP Group +-------------------------------- + +wtWebGraphThermHygroUdpPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Udp Port, an den die Udp-Anfragen GET Single gesendet werden können" + ::= { wtWebGraphThermHygroUDP 1 } + +wtWebGraphThermHygroUdpEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Schaltet UDP frei: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 1-7: ungenutzt + Bit 0 : UDP enable" + ::= { wtWebGraphThermHygroUDP 2 } + +-- wtWebGraphThermHygroSyslog Group +-------------------------------- + +wtWebGraphThermHygroSyslogServerIP OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name oder IP-Adresse des Syslog-Servers, der die Syslog-Nachricht entgegen nimmt." + ::= { wtWebGraphThermHygroSyslog 1 } + +wtWebGraphThermHygroSyslogServerPort OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Portnummer des Syslog-Servers, default ist 514." + ::= { wtWebGraphThermHygroSyslog 2 } + +wtWebGraphThermHygroSyslogSystemMessagesEnable OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Triggerbedingungen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: ColdStart + Bit 1: WarmStart + Bit 2: Diag Messages + Bit 3-7: ungenutzt" + ::= { wtWebGraphThermHygroSyslog 3 } + +wtWebGraphThermHygroSyslogEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bit 0 schaltet Syslog frei: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 1-7: ungenutzt + Bit 0 : Syslog enable" + ::= { wtWebGraphThermHygroSyslog 4 } + +-- wtWebGraphThermHygroFTP Group +-------------------------------- + +wtWebGraphThermHygroFTPServerIP OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name oder IP-Adresse des FTP-Servers, der die FTP-Nachricht entgegen nimmt." + ::= { wtWebGraphThermHygroFTP 1 } + +wtWebGraphThermHygroFTPServerControlPort OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Portnummer des Kontrollports des FTP-Servers, default ist 21." + ::= { wtWebGraphThermHygroFTP 2 } + +wtWebGraphThermHygroFTPUserName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "FTP Loggin: Name des Anwenders." + ::= { wtWebGraphThermHygroFTP 3 } + +wtWebGraphThermHygroFTPPassword OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "FTP Loggin: Passwort des Anwenders." + ::= { wtWebGraphThermHygroFTP 4 } + +wtWebGraphThermHygroFTPAccount OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "FTP Loggin: Account-Name des Anwenderkontos." + ::= { wtWebGraphThermHygroFTP 5 } + +wtWebGraphThermHygroFTPOption OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bit 0 schaltet den FTP Server in den Passiv-Modus, + der Client kontrolliert die Datenverbindung allein: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 1-7: ungenutzt + Bit 0 : PASV enable" + ::= { wtWebGraphThermHygroFTP 6 } + +wtWebGraphThermHygroFTPEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bit 0 schaltet FTP frei: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 1-7: ungenutzt + Bit 0 : FTP enable" + ::= { wtWebGraphThermHygroFTP 7 } + + +-- wtWebGraphThermHygroDatalogger Group +-------------------------------- + +wtWebGraphThermHygroLoggerTimebase OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermHygroDatalogger-1Min(1), + wtWebGraphThermHygroDatalogger-5Min(2), + wtWebGraphThermHygroDatalogger-15Min(3), + wtWebGraphThermHygroDatalogger-60Min(4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Zeitbasis des Dataloggers" + ::= { wtWebGraphThermHygroDatalogger 1 } + +wtWebGraphThermHygroLoggerSensorSel OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Triggerbedingungen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0 : Sensor 1 + Bit 1 : Sensor 2 + Bit 2-7: ungenutzt" + ::= { wtWebGraphThermHygroDatalogger 2 } + +wtWebGraphThermHygroDisplaySensorSel OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Die hier ausgewählten Sensoren werden grafisch angezeigt: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: Sensor 1 + Bit 1: Sensor 2 + Bit 2-7: ungenutzt" + ::= { wtWebGraphThermHygroDatalogger 3 } + +-- Graph Sensor Color Table + +wtWebGraphThermHygroSensorColorTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebGraphThermHygroSensorColorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste der Sensorfarben in der grafischen Darstellung." + ::= { wtWebGraphThermHygroDatalogger 4 } + +wtWebGraphThermHygroSensorColorEntry OBJECT-TYPE + SYNTAX WtWebGraphThermHygroSensorColorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Nummern der Sensoren." + INDEX { wtWebGraphThermHygroSensorNo } + ::= { wtWebGraphThermHygroSensorColorTable 1 } + +WtWebGraphThermHygroSensorColorEntry ::= SEQUENCE { + wtWebGraphThermHygroSensorColor OCTET STRING +} + +wtWebGraphThermHygroSensorColor OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(3)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Farbe des Sensors in der grafischen Darstellung." + ::= { wtWebGraphThermHygroSensorColorEntry 1 } + +wtWebGraphThermHygroAutoScaleEnable OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bit 0 schaltet Vertical Auto Scale frei: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 1-7: ungenutzt + Bit 0 : Auto Scale enable" + ::= { wtWebGraphThermHygroDatalogger 5 } + +wtWebGraphThermHygroVerticalUpperLimit OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Definiert die maximal sichtbare Temperatur für die grafische Darstellung. + Temperatur in Grad mit maximal 2 Nachkommastellen." + ::= { wtWebGraphThermHygroDatalogger 6 } + +wtWebGraphThermHygroVerticalLowerLimit OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Definiert die Minal sichtbare Temperatur für die grafische Darstellung. + Temperatur in Grad mit maximal 2 Nachkommastellen." + ::= { wtWebGraphThermHygroDatalogger 7 } + +wtWebGraphThermHygroHorizontalZoom OBJECT-TYPE + SYNTAX INTEGER { + wtWebGraphThermHygroZoom-25Min(1), + wtWebGraphThermHygroZoom-75Min(2), + wtWebGraphThermHygroZoom-5Std(3), + wtWebGraphThermHygroZoom-30Std(4), + wtWebGraphThermHygroZoom-5Tage(5), + wtWebGraphThermHygroZoom-25Tage(6) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Definiert den default Zoom." + ::= { wtWebGraphThermHygroDatalogger 8 } + +-- wtWebGraphThermHygroAlarm Group +---------------------------- + +wtWebGraphThermHygroAlarmCount OBJECT-TYPE + SYNTAX INTEGER (1..8) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Anzahl der unabhängigen Alarme." + ::= { wtWebGraphThermHygroAlarm 1 } + +-- Alarm Interface Table + +wtWebGraphThermHygroAlarmIfTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebGraphThermHygroAlarmIfEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste der Alarmindizes." + ::= { wtWebGraphThermHygroAlarm 2 } + +wtWebGraphThermHygroAlarmIfEntry OBJECT-TYPE + SYNTAX WtWebGraphThermHygroAlarmIfEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Nummern der Alarme." + INDEX { wtWebGraphThermHygroAlarmNo } + ::= { wtWebGraphThermHygroAlarmIfTable 1 } + +WtWebGraphThermHygroAlarmIfEntry ::= SEQUENCE { + wtWebGraphThermHygroAlarmNo INTEGER +} + +wtWebGraphThermHygroAlarmNo OBJECT-TYPE + SYNTAX INTEGER (1..8) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Nummer des Alarms." + ::= { wtWebGraphThermHygroAlarmIfEntry 1 } + +-- Alarm Table + +wtWebGraphThermHygroAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebGraphThermHygroAlarmEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste der Einstellungen abhängig von der Alarmnummer." + ::= { wtWebGraphThermHygroAlarm 3 } + +wtWebGraphThermHygroAlarmEntry OBJECT-TYPE + SYNTAX WtWebGraphThermHygroAlarmEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Alarm-Parameter der einzelnen Alarme." + INDEX { wtWebGraphThermHygroAlarmNo } + ::= { wtWebGraphThermHygroAlarmTable 1 } + +WtWebGraphThermHygroAlarmEntry ::= SEQUENCE { + wtWebGraphThermHygroAlarmTrigger OCTET STRING, + wtWebGraphThermHygroAlarmMin OCTET STRING, + wtWebGraphThermHygroAlarmMax OCTET STRING, + wtWebGraphThermHygroAlarmHysteresis OCTET STRING, + wtWebGraphThermHygroAlarmDelay OCTET STRING, + wtWebGraphThermHygroAlarmInterval OCTET STRING, + wtWebGraphThermHygroAlarmEnable OCTET STRING, + wtWebGraphThermHygroAlarmEMailAddr OCTET STRING, + wtWebGraphThermHygroAlarmMailSubject OCTET STRING, + wtWebGraphThermHygroAlarmMailText OCTET STRING, + wtWebGraphThermHygroAlarmManagerIP OCTET STRING, + wtWebGraphThermHygroAlarmTrapText OCTET STRING, + wtWebGraphThermHygroAlarmMailOptions OCTET STRING, + wtWebGraphThermHygroAlarmTcpIpAddr OCTET STRING, + wtWebGraphThermHygroAlarmTcpPort INTEGER, + wtWebGraphThermHygroAlarmTcpText OCTET STRING, + wtWebGraphThermHygroAlarmClearMailSubject OCTET STRING, + wtWebGraphThermHygroAlarmClearMailText OCTET STRING, + wtWebGraphThermHygroAlarmClearTrapText OCTET STRING, + wtWebGraphThermHygroAlarmClearTcpText OCTET STRING, + wtWebGraphThermHygroAlarmDeltaTemp OCTET STRING, + wtWebGraphThermHygroAlarmRHMin OCTET STRING, + wtWebGraphThermHygroAlarmRHMax OCTET STRING, + wtWebGraphThermHygroAlarmRHHysteresis OCTET STRING, + wtWebGraphThermHygroAlarmAHMin OCTET STRING, + wtWebGraphThermHygroAlarmAHMax OCTET STRING, + wtWebGraphThermHygroAlarmSyslogIpAddr OCTET STRING, + wtWebGraphThermHygroAlarmSyslogPort INTEGER, + wtWebGraphThermHygroAlarmSyslogText OCTET STRING, + wtWebGraphThermHygroAlarmSyslogClearText OCTET STRING, + wtWebGraphThermHygroAlarmFtpDataPort OCTET STRING, + wtWebGraphThermHygroAlarmFtpFileName OCTET STRING, + wtWebGraphThermHygroAlarmFtpText OCTET STRING, + wtWebGraphThermHygroAlarmFtpClearText OCTET STRING, + wtWebGraphThermHygroAlarmFtpOption OCTET STRING, + wtWebGraphThermHygroAlarmTimerCron OCTET STRING + +} + +wtWebGraphThermHygroAlarmTrigger OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Triggerbedingungen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: + Bit 0: Timer + Bit 1: ColdStart + Bit 2: WarmStart + Bit 3: Sensor lost + Bit 4-7 ungenutzt + Octet 4: + Bit 0: Sensor 1 + Bit 1: Sensor 2 + Bit 2-7: ungenutzt" + ::= { wtWebGraphThermHygroAlarmEntry 1 } + +wtWebGraphThermHygroAlarmMin OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minimum Temperatur in Grad mit maximal 2 Nachkommastellen." + ::= { wtWebGraphThermHygroAlarmEntry 2 } + +wtWebGraphThermHygroAlarmMax OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximum Temperatur in Grad mit maximal 2 Nachkommastellen." + ::= { wtWebGraphThermHygroAlarmEntry 3 } + +wtWebGraphThermHygroAlarmHysteresis OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bei Überschreiten der Temperatur Min+Hyst. und Unterschreiten der Temperatur Max-Hyst. + wird der Alarm gelöscht: pos. Temperaturdifferenz in Grad mit maximal 2 Nachkommastellen." + ::= { wtWebGraphThermHygroAlarmEntry 4 } + +wtWebGraphThermHygroAlarmDelay OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Der Alarm wird erst ausgelöst, wenn für die Dauer dieser Zeit + die Alarmbedingungen erfüllt sind (Zeit in Minuten)." + ::= { wtWebGraphThermHygroAlarmEntry 5 } + +wtWebGraphThermHygroAlarmInterval OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Sendeintervall von Alarmmeldungen." + ::= { wtWebGraphThermHygroAlarmEntry 6 } + +wtWebGraphThermHygroAlarmEnable OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Alarmfreischaltung: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0: Mail Enable + Bit 1: SNMP Trap enable + Bit 2: TCP Client enable" + ::= { wtWebGraphThermHygroAlarmEntry 7 } + +wtWebGraphThermHygroAlarmEMailAddr OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "E-Mail Adresse, an die die Alarmmail gesendet werden soll." + ::= { wtWebGraphThermHygroAlarmEntry 8 } + +wtWebGraphThermHygroAlarmMailSubject OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Betreffzeile der Alarmmail." + ::= { wtWebGraphThermHygroAlarmEntry 9 } + +wtWebGraphThermHygroAlarmMailText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Text der Alarmmail: liefert die aktuelle Temperatur; n = 1..8. + liefert die aktuelle Zeit." + ::= { wtWebGraphThermHygroAlarmEntry 10 } + +wtWebGraphThermHygroAlarmManagerIP OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name oder IP-Adresse des SNMP-Managers, der den Trap entgegen nimmt." + ::= { wtWebGraphThermHygroAlarmEntry 11 } + +wtWebGraphThermHygroAlarmTrapText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieser Text wird im Trapbody gesendet." + ::= { wtWebGraphThermHygroAlarmEntry 12 } + +wtWebGraphThermHygroAlarmMailOptions OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Optionen: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0 : Attach Thermo.csv Enable + Bit 1 : CSV-Data_since_last_report + Bit 2-7: ungenutzt" + ::= { wtWebGraphThermHygroAlarmEntry 13 } + +wtWebGraphThermHygroAlarmTcpIpAddr OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse des Gerätes, dass eine TCP-Nachricht empfangen soll." + ::= { wtWebGraphThermHygroAlarmEntry 14 } + +wtWebGraphThermHygroAlarmTcpPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Portnummer des Gerätes, dass eine TCP-Nachricht empfangen soll." + ::= { wtWebGraphThermHygroAlarmEntry 15 } + +wtWebGraphThermHygroAlarmTcpText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieser Text wird im TCP Trapbody gesendet." + ::= { wtWebGraphThermHygroAlarmEntry 16 } + +wtWebGraphThermHygroAlarmClearMailSubject OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Betreffzeile der Alarm Clear Mail." + ::= { wtWebGraphThermHygroAlarmEntry 17 } + +wtWebGraphThermHygroAlarmClearMailText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Text der Alarm Clear Mail: liefert die aktuelle Temperatur; n = 1..8. + liefert die aktuelle Zeit." + ::= { wtWebGraphThermHygroAlarmEntry 18 } + +wtWebGraphThermHygroAlarmClearTrapText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieser Text wird im Trapbody gesendet." + ::= { wtWebGraphThermHygroAlarmEntry 19 } + +wtWebGraphThermHygroAlarmClearTcpText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieser Text wird im TCP Trapbody gesendet." + ::= { wtWebGraphThermHygroAlarmEntry 20 } + +wtWebGraphThermHygroAlarmDeltaTemp OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximale Temperaturänderung in Grad/min mit maximal 2 Nachkommastellen. + Es wird ein Mittelwert einer Periode von 5 Minuten verglichen." + ::= { wtWebGraphThermHygroAlarmEntry 21 } + +wtWebGraphThermHygroAlarmRHMin OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minimum rel. Feuchte in Prozent mit maximal 2 Nachkommastellen." + ::= { wtWebGraphThermHygroAlarmEntry 22 } + +wtWebGraphThermHygroAlarmRHMax OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximum rel.Feuchte in Prozent mit maximal 2 Nachkommastellen." + ::= { wtWebGraphThermHygroAlarmEntry 23 } + +wtWebGraphThermHygroAlarmRHHysteresis OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Hysterese rel. Feuchte in Prozent mit maximal 2 Nachkommastellen." + ::= { wtWebGraphThermHygroAlarmEntry 24 } + +wtWebGraphThermHygroAlarmAHMin OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Minimum abs. Feuchte in g/(m*m*m) mit maximal 2 Nachkommastellen." + ::= { wtWebGraphThermHygroAlarmEntry 25 } + +wtWebGraphThermHygroAlarmAHMax OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Maximum abs. Feuchte in g/(m*m*m) mit maximal 2 Nachkommastellen." + ::= { wtWebGraphThermHygroAlarmEntry 26 } + +wtWebGraphThermHygroAlarmSyslogIpAddr OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "IP-Adresse des Gerätes, dass eine Syslog-Nachricht empfangen soll." + ::= { wtWebGraphThermHygroAlarmEntry 27 } + +wtWebGraphThermHygroAlarmSyslogPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Portnummer des Gerätes, dass eine Syslog-Nachricht empfangen soll, default Port ist 514." + ::= { wtWebGraphThermHygroAlarmEntry 28 } + +wtWebGraphThermHygroAlarmSyslogText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Jede Syslog-Nachricht beginnt mit einem Prioritätsschlüssel, einem Zeitstempel und der Host Ip-Nummer gemäß RFC3164. + Dieser Text wird im darauf folgenden Syslog-Nachrichtenteil gesendet." + ::= { wtWebGraphThermHygroAlarmEntry 29 } + +wtWebGraphThermHygroAlarmSyslogClearText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Jede Syslog-Nachricht beginnt mit einem Prioritätsschlüssel, einem Zeitstempel und der Host Ip-Nummer gemäß RFC3164. + Dieser Text wird im darauf folgenden Syslog-Nachrichtenteil gesendet." + ::= { wtWebGraphThermHygroAlarmEntry 30 } + +wtWebGraphThermHygroAlarmFtpDataPort OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Lokaler Datenport: 1..65535 oder AUTO: der nächste ungenutzte Port wird automatisch zugewiesen." + ::= { wtWebGraphThermHygroAlarmEntry 31 } + +wtWebGraphThermHygroAlarmFtpFileName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Der File Name kann auch Pfadinformationen enthalten." + ::= { wtWebGraphThermHygroAlarmEntry 32 } + +wtWebGraphThermHygroAlarmFtpText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieser Text wird in die angegebene Datei geschrieben." + ::= { wtWebGraphThermHygroAlarmEntry 33 } + +wtWebGraphThermHygroAlarmFtpClearText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Dieser Text wird in die angegebene Datei geschrieben." + ::= { wtWebGraphThermHygroAlarmEntry 34 } + +wtWebGraphThermHygroAlarmFtpOptions OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Optionen, nur eine Option darf eingeschaltet sein: + STORE = Datei ersetzen + APPEND = Nachrichten ans Dateiende anhängen + + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0 : STORE + Bit 1 : APPEND + Bit 2-7: ungenutzt" + ::= { wtWebGraphThermHygroAlarmEntry 35 } + +wtWebGraphThermHygroAlarmTimerCron OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Diser Eintrag enthält 5 Leerzeichen- oder Tab-getrente Felder zur Definition von zeitgesteuerten + Ausgabe von Alarmnachrichten. Jedes der 5 Felder muss mit der aktuelle Zeit übereinstimmen, um + das Senden einer Nachricht auszulösen, Wochentag und Monatstag werden getrennt ausgewertet. + Feld möglicher Zahlenbereich + 1: Minuten 0-59 + 2. Stunden 0-23, 0 ist Mitternacht + 3: Monatstag 1-31 + 4: Monat 1-12 + 5: Wochentag 0-6, 0 ist Sonntag + + Für jedes Feld kann nun angegeben werden: + - eine ganze Zahl aus dem angegebenen Zahlenbereich + - ein Teil-Zahlenbereich (wie z.B. 1-5) innerhalb des angegebenen Zahlenbereichs + - eine mit Komma getrennte Liste von ganzen Zahlen oder Tei-Zahlenbereichen (wie z.B. 2,4-6,8,10) + - ein Stern * (deckt den gesamten erlaubten Bereich ab) + - ein / gibt die Schrittweite bei Teil-Zahlenbereichen an (z.B. 0-59/2 jede zweite Minute)." + ::= { wtWebGraphThermHygroAlarmEntry 36 } + +-- wtWebGraphThermHygroPorts Group +---------------------------- + +-- Table + +wtWebGraphThermHygroPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF WtWebGraphThermHygroPortEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Liste der Einstellungen abhängig von der Sensornummer." + ::= { wtWebGraphThermHygroPorts 1 } + +wtWebGraphThermHygroPortEntry OBJECT-TYPE + SYNTAX WtWebGraphThermHygroPortEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Sensor-Parameter der einzelnen Sensoren." + INDEX { wtWebGraphThermHygroSensorNo } + ::= { wtWebGraphThermHygroPortTable 1 } + +WtWebGraphThermHygroPortEntry ::= SEQUENCE { + wtWebGraphThermHygroPortName OCTET STRING, + wtWebGraphThermHygroPortText OCTET STRING, + wtWebGraphThermHygroPortOffset1 OCTET STRING, + wtWebGraphThermHygroPortTemperature1 OCTET STRING, + wtWebGraphThermHygroPortOffset2 OCTET STRING, + wtWebGraphThermHygroPortTemperature2 OCTET STRING, + wtWebGraphThermHygroPortComment OCTET STRING, + wtWebGraphThermHygroPortSensorSelect OCTET STRING +} + +wtWebGraphThermHygroPortName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Name des Sensors." + ::= { wtWebGraphThermHygroPortEntry 1 } + +wtWebGraphThermHygroPortText OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Beschreibung des Sensors." + ::= { wtWebGraphThermHygroPortEntry 2 } + +wtWebGraphThermHygroPortOffset1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 1." + ::= { wtWebGraphThermHygroPortEntry 3 } + +wtWebGraphThermHygroPortTemperature1 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Referenztemperatur 1 in Grad mit max. 2 Nachkommastellen." + ::= { wtWebGraphThermHygroPortEntry 4 } + +wtWebGraphThermHygroPortOffset2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 2." + ::= { wtWebGraphThermHygroPortEntry 5 } + +wtWebGraphThermHygroPortTemperature2 OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Referenztemperatur 2 in Grad mit max. 2 Nachkommastellen." + ::= { wtWebGraphThermHygroPortEntry 6 } + +wtWebGraphThermHygroPortComment OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Offset-Kalibrierung: Angaben zu Datum, Referenzgerät, Operator." + ::= { wtWebGraphThermHygroPortEntry 7 } + +wtWebGraphThermHygroPortSensorSelect OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(4)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Binär kodierte Optionen für Sensor 1: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0 : PT100 + Bit 1 : PT1000 (default) + Bit 2-7: ungenutzt + + Binär kodierte Optionen für Sensor 2: + Octet 1: ungenutzt + Octet 2: ungenutzt + Octet 3: ungenutzt + Octet 4: + Bit 0 : W&T Sensor rel. Feuchte (default) + Bit 1 : Skalar 0-2.5V + Bit 2 : Disconnect + Bit 3-7: ungenutzt" + ::= { wtWebGraphThermHygroPortEntry 8 } + +-- wtWebGraphThermHygroManufact Group +---------------------------- + +wtWebGraphThermHygroMfName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Hersteller Firmenname" + ::= { wtWebGraphThermHygroManufact 1 } + +wtWebGraphThermHygroMfAddr OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Adresse des Herstellers." + ::= { wtWebGraphThermHygroManufact 2 } + +wtWebGraphThermHygroMfHotline OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Hotline des Herstellers." + ::= { wtWebGraphThermHygroManufact 3 } + +wtWebGraphThermHygroMfInternet OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Internet-Adresse des Herstellers." + ::= { wtWebGraphThermHygroManufact 4 } + +wtWebGraphThermHygroMfDeviceTyp OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Gerätebezeichnung (Typ) des Herstellers." + ::= { wtWebGraphThermHygroManufact 5 } + +wtWebGraphThermHygroMfOrderNo OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Bestellnummer des Gerätes des Herstellers." + ::= { wtWebGraphThermHygroManufact 6 } + +-- wtWebGraphThermHygroDiag Group +---------------------------- + +wtWebGraphThermHygroDiagErrorCount OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Anzahl der Einträge im Fehlerspeicher." + ::= { wtWebGraphThermHygroDiag 1 } + +wtWebGraphThermHygroDiagBinaryError OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Bitweise kodierte Fehlerursachen." + ::= { wtWebGraphThermHygroDiag 2 } + +wtWebGraphThermHygroDiagErrorIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Der Wert dieser Variable wird als Index für die Ausgabe + eines Fehlertextes (wtWebGraphThermHygroDiagErrorMessage) verwendet. + Die Fehler im Speicher sind von 1 bis wtWebGraphThermHygroDiagErrorCount durchnummeriert. + Nach dem Schreiben einens gültigen Wertes in diese Variable kann der dazugehörige Text + in wtWebGraphThermHygroDiagErrorMessage ausgelesen werden." + ::= { wtWebGraphThermHygroDiag 3 } + +wtWebGraphThermHygroDiagErrorMessage OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Abhängig vom Wert wtWebGraphThermHygroDiagErrorIndex wird ein Fehlertext angezeigt." + ::= { wtWebGraphThermHygroDiag 4 } + +wtWebGraphThermHygroDiagErrorClear OBJECT-TYPE + SYNTAX INTEGER + ACCESS write-only + STATUS mandatory + DESCRIPTION + "Durch Schreiben eine 1 in diese Variable, wird der Fehlerspeicher gelöscht." + ::= { wtWebGraphThermHygroDiag 5 } + +-- TRAP DEFINITIONS + +-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen + +wtWebGraphThermHygroAlert1 TRAP-TYPE + ENTERPRISE wtWebGraphThermHygro + VARIABLES { wtWebGraphThermHygroAlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 1 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Alarm 1" + --#SUMMARY "Alarm 1: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 31 + +wtWebGraphThermHygroAlert2 TRAP-TYPE + ENTERPRISE wtWebGraphThermHygro + VARIABLES { wtWebGraphThermHygroAlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 2 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Alarm 2" + --#SUMMARY "Alarm 2: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 32 + +wtWebGraphThermHygroAlert3 TRAP-TYPE + ENTERPRISE wtWebGraphThermHygro + VARIABLES { wtWebGraphThermHygroAlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 3 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Alarm 3" + --#SUMMARY "Alarm 3: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 33 + +wtWebGraphThermHygroAlert4 TRAP-TYPE + ENTERPRISE wtWebGraphThermHygro + VARIABLES { wtWebGraphThermHygroAlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 4 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Alarm 4" + --#SUMMARY "Alarm 4: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 34 + +wtWebGraphThermHygroAlert5 TRAP-TYPE + ENTERPRISE wtWebGraphThermHygro + VARIABLES { wtWebGraphThermHygroAlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 5 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Alarm 5" + --#SUMMARY "Alarm 5: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 35 + +wtWebGraphThermHygroAlert6 TRAP-TYPE + ENTERPRISE wtWebGraphThermHygro + VARIABLES { wtWebGraphThermHygroAlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 6 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Alarm 6" + --#SUMMARY "Alarm 6: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 36 + +wtWebGraphThermHygroAlert7 TRAP-TYPE + ENTERPRISE wtWebGraphThermHygro + VARIABLES { wtWebGraphThermHygroAlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 7 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Alarm 7" + --#SUMMARY "Alarm 7: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 37 + +wtWebGraphThermHygroAlert8 TRAP-TYPE + ENTERPRISE wtWebGraphThermHygro + VARIABLES { wtWebGraphThermHygroAlarmTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 8 ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Alarm 8" + --#SUMMARY "Alarm 8: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 38 + +wtWebGraphThermHygroAlert9 TRAP-TYPE + ENTERPRISE wtWebGraphThermHygro + VARIABLES { wtWebGraphThermHygroAlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 1 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Release Alarm 1" + --#SUMMARY "Release Alarm 1: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 91 + +wtWebGraphThermHygroAlert10 TRAP-TYPE + ENTERPRISE wtWebGraphThermHygro + VARIABLES { wtWebGraphThermHygroAlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 2 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Release Alarm 2" + --#SUMMARY "Release Alarm 2: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 92 + +wtWebGraphThermHygroAlert11 TRAP-TYPE + ENTERPRISE wtWebGraphThermHygro + VARIABLES { wtWebGraphThermHygroAlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 3 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Release Alarm 3" + --#SUMMARY "Release Alarm 3: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 93 + +wtWebGraphThermHygroAlert12 TRAP-TYPE + ENTERPRISE wtWebGraphThermHygro + VARIABLES { wtWebGraphThermHygroAlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 4 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Release Alarm 4" + --#SUMMARY "Release Alarm 4: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 94 + +wtWebGraphThermHygroAlert13 TRAP-TYPE + ENTERPRISE wtWebGraphThermHygro + VARIABLES { wtWebGraphThermHygroAlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 5 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Release Alarm 5" + --#SUMMARY "Release Alarm 5: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 95 + +wtWebGraphThermHygroAlert14 TRAP-TYPE + ENTERPRISE wtWebGraphThermHygro + VARIABLES { wtWebGraphThermHygroAlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 6 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Release Alarm 6" + --#SUMMARY "Release Alarm 6: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 96 + +wtWebGraphThermHygroAlert15 TRAP-TYPE + ENTERPRISE wtWebGraphThermHygro + VARIABLES { wtWebGraphThermHygroAlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 7 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Release Alarm 7" + --#SUMMARY "Release Alarm 7: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 97 + +wtWebGraphThermHygroAlert16 TRAP-TYPE + ENTERPRISE wtWebGraphThermHygro + VARIABLES { wtWebGraphThermHygroAlarmClearTrapText } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn der Alarm 8 gelöscht wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Release Alarm 8" + --#SUMMARY "Release Alarm 8: %s" + --#ARGUMENTS {0} + --#SEVERITY INFORMATIONAL + --#TIMEINDEX 99 + --#STATE OPERATIONAL + ::= 98 + +wtWebGraphThermHygroAlertDiag TRAP-TYPE + ENTERPRISE wtWebGraphThermHygro + VARIABLES { + wtWebGraphThermHygroDiagErrorIndex, + wtWebGraphThermHygroDiagErrorMessage + } + DESCRIPTION + "Dieser SNMP-Trap wird generiert, wenn eine Diagnose/Error-Message ausgelöst wurde, + das SNMP-Trap-Enable gesetzt ist und + SNMP in Enable freigegeben ist." + -- NMS trap annotation + --#TYPE "Thermo-Hygrometer Diagnose Error" + --#SUMMARY "Diagnose error index: %d, Message: %s." + --#ARGUMENTS {0,1} + --#SEVERITY MAJOR + --#TIMEINDEX 99 + --#STATE DEGRADED + ::= 110 + +END -- cgit v1.2.3