mibs/MIBS/accedian/ACD-SFP-MIB

1183 lines
39 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
--
-- Accedian Enterprise Specific MIB
--
-- Copyright (c) 2005-2010, Accedian Networks, Inc.
-- All rights reserved.
--
-- The contents of this document is subject to change without notice.
--
ACD-SFP-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Integer32, Unsigned32
FROM SNMPv2-SMI
DisplayString, TruthValue
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
acdMibs
FROM ACCEDIAN-SMI;
acdSfp MODULE-IDENTITY
LAST-UPDATED "201011100100Z"
ORGANIZATION "Accedian Networks, Inc."
CONTACT-INFO
"Accedian Technical Assistance Center
Accedian Networks, Inc.
4878 Levy, suite 202
Saint-Laurent, Quebec Canada H4R 2P1
E-mail: support@accedian.com"
DESCRIPTION
"The SFPs database for this Accedian Networks device."
REVISION "201011100100Z" -- 10 November 2010
DESCRIPTION
"Add compliance section."
REVISION "200804220100Z" -- 22 April 2008
DESCRIPTION
"Add acdSfpInfoIdType, acdSfpInfoExtIdType and acdSfpInfoTransCode support."
REVISION "200608060100Z" -- 6 Aug 2006
DESCRIPTION
"Initial version of MIB module ACD-SFP-MIB."
::= { acdMibs 4 }
acdSfpNotifications OBJECT IDENTIFIER ::= { acdSfp 5 }
acdSfpMIBObjects OBJECT IDENTIFIER ::= { acdSfp 6 }
acdSfpConformance OBJECT IDENTIFIER ::= { acdSfp 7 }
-----------------------------------------------------------------------
-- The information SFP table
-- This table contains all SFP Info.
---------------------------------------------------------------------------
acdSfpInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcdSfpInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of all SFP info"
::= { acdSfp 1 }
acdSfpInfoEntry OBJECT-TYPE
SYNTAX AcdSfpInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a part of the content of the SFP's 0xA0 EEPROM"
INDEX { acdSfpInfoID }
::= { acdSfpInfoTable 1 }
AcdSfpInfoEntry ::= SEQUENCE {
acdSfpInfoID Unsigned32,
acdSfpInfoConnIdx Unsigned32,
acdSfpInfoConnType INTEGER,
acdSfpInfoVendor DisplayString,
acdSfpInfoVendorOui DisplayString,
acdSfpInfoVendorPn DisplayString,
acdSfpInfoVendorRev DisplayString,
acdSfpInfoWavelength Unsigned32,
acdSfpInfoSerialNum DisplayString,
acdSfpInfoYear Unsigned32,
acdSfpInfoMonth Unsigned32,
acdSfpInfoDay Unsigned32,
acdSfpInfoLot Unsigned32,
acdSfpInfoRev8472 INTEGER,
acdSfpInfoPresent TruthValue,
acdSfpInfoDiag TruthValue,
acdSfpInfoInternal TruthValue,
acdSfpInfoAlm TruthValue,
acdSfpInfoIdType Unsigned32,
acdSfpInfoExtIdType Unsigned32,
acdSfpInfoTransCode DisplayString
}
acdSfpInfoID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique value for each SFP. Its value ranges from 1 to
MAXINT (4 bytes). "
::= { acdSfpInfoEntry 1 }
acdSfpInfoConnIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the connector index on the box. The index
is assigned form left to rigth starting with 1."
::= { acdSfpInfoEntry 2 }
acdSfpInfoConnType OBJECT-TYPE
SYNTAX INTEGER {
sfpSC(1),
sfpFC1COPPER(2),
sfpFC2COPPER(3),
sfpBNC(4),
sfpFCCOAX(5),
sfpFIBERJACK(6),
sfpLC(7),
sfpMTRJ(8),
sfpMU(9),
sfpSG(10),
sfpPIGTAIL(11),
sfpHSSDCII(32),
sfpCOPPERPIGTAIL(33)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The connector value indicates the external optical or electrical
cable connector provided as the media interface."
::= { acdSfpInfoEntry 3 }
acdSfpInfoVendor OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor name is a 16 character field that contains ASCII
characters, left-aligned and padded on the right with ASCII
spaces (20h). The vendor name shall be the full name of the
corporation, a commonly accepted abbreviation of the name of
the corporation, the SCSI company code for the corporation,
or the stock exchange code for the corporation. At least one
of the vendor name or the vendor OUI fields shall contain
valid serial data."
::= { acdSfpInfoEntry 4 }
acdSfpInfoVendorOui OBJECT-TYPE
SYNTAX DisplayString (SIZE (3))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor organizationally unique identifier field (vendor OUI)
is a 3-byte field that contains the IEEE Company Identifier for
the vendor. A value of all zero in the 3-byte field indicates
that the Vendor OUI is unspecified."
::= { acdSfpInfoEntry 5 }
acdSfpInfoVendorPn OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor part number (vendor PN) is a 16-byte field that
contains ASCII characters, leftaligned and padded on the
right with ASCII spaces (20h), defining the vendor's part
number or product name. A value of all zero in the 16-byte
field indicates that the vendor PN is unspecified."
::= { acdSfpInfoEntry 6 }
acdSfpInfoVendorRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor revision number (vendor rev) is a 4-byte field that
contains ASCII characters, leftaligned and padded on the right
with ASCII spaces (20h), defining the vendor's product revision
number. A value of all zero in the 4-byte field indicates that
the vendor PN is unspecified."
::= { acdSfpInfoEntry 7 }
acdSfpInfoWavelength OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Nominal transmitter output wavelength at room temperature. 16 bit
value with byte 60 as high order byte and byte 61 as low order
byte. The laser wavelength is equal to the 16 bit integer
value in nm. This field allows the user to read the laser
wavelength directly, so it is not necessary to infer it from the
transceiver Code for Electronic Compatibility."
::= { acdSfpInfoEntry 8 }
acdSfpInfoSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor serial number (vendor SN) is a 16 character field that
contains ASCII characters, left-aligned and padded on the right
with ASCII spaces (20h), defining the vendor's serial number for
the transceiver. A value of all zero in the 16-byte field indicates
that the vendor PN is unspecified."
::= { acdSfpInfoEntry 9 }
acdSfpInfoYear OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the year of manufacturing."
::= { acdSfpInfoEntry 10 }
acdSfpInfoMonth OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the month of manufacturing."
::= { acdSfpInfoEntry 11 }
acdSfpInfoDay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the day of manufacturing."
::= { acdSfpInfoEntry 12 }
acdSfpInfoLot OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the Lot number of manufacturing."
::= { acdSfpInfoEntry 13 }
acdSfpInfoRev8472 OBJECT-TYPE
SYNTAX INTEGER {
undefined(0),
rev93(1),
rev94(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate to which revision this SFP is compatible."
::= { acdSfpInfoEntry 14 }
acdSfpInfoPresent OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the SFP is present or not."
::= { acdSfpInfoEntry 15 }
acdSfpInfoDiag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the SFP supports Digital Diagnostics."
::= { acdSfpInfoEntry 16 }
acdSfpInfoInternal OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the SFP supports internal calibration. If
externally calibrated, the measurements are raw A/D values and must
be converted to real world units using calibration constants
stored in EEPROM locations 56 to 95 at 2 wire serial bus address
A2h. Calibration is valid over vendor specified operating
temperature and voltage. Alarm and warning threshold values
should be interpreted in the same manner as real time 16 bit data."
::= { acdSfpInfoEntry 17 }
acdSfpInfoAlm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the SFP supports Alarm and warning
thresholds for the Digital Diagnostics."
::= { acdSfpInfoEntry 18 }
acdSfpInfoIdType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The identifier value specifies the physical device described by
the two-wire interface information. This value shall be included
in the two-wire interface data (see SFF-8472 for details)."
::= { acdSfpInfoEntry 19 }
acdSfpInfoExtIdType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The extended identifier value provides additional information
about the transceiver. The field should be set to 04h for all SFP
modules indicating two-wire interface ID module definition (see
SFF-8472 for details)."
::= { acdSfpInfoEntry 20 }
acdSfpInfoTransCode OBJECT-TYPE
SYNTAX DisplayString (SIZE (8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The following bit significant indicators define the electronic
or optical interfaces that are supported by the transceiver. At
least one bit shall be set in this field (see SFF-8472 for details)."
::= { acdSfpInfoEntry 21 }
-----------------------------------------------------------------------
-- The Digital Diagnostics SFP table
-- This table contains all SFP Digital Diagnostics.
---------------------------------------------------------------------------
acdSfpDiagTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcdSfpDiagEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of all SFP Digital Diagnostics"
::= { acdSfp 2 }
acdSfpDiagEntry OBJECT-TYPE
SYNTAX AcdSfpDiagEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a part the content of the SFP's 0xA0 EEPROM"
INDEX { acdSfpDiagID }
::= { acdSfpDiagTable 1 }
AcdSfpDiagEntry ::= SEQUENCE {
acdSfpDiagID Unsigned32,
acdSfpDiagConnIdx Unsigned32,
acdSfpDiagTemp Integer32,
acdSfpDiagVcc Unsigned32,
acdSfpDiagLbc Unsigned32,
acdSfpDiagTxPwr Unsigned32,
acdSfpDiagRxPwr Unsigned32,
acdSfpDiagTxPwrdBm DisplayString,
acdSfpDiagRxPwrdBm DisplayString
}
acdSfpDiagID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique value for each SFP. Its value ranges from 1 to
MAXINT (4 bytes). "
::= { acdSfpDiagEntry 1 }
acdSfpDiagConnIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the connector index on the box. The index
is assigned form left to rigth starting with 1."
::= { acdSfpDiagEntry 2 }
acdSfpDiagTemp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Internally measured transceiver temperature. Represented as a
16 bit signed twos complement value in degrees Celsius, yielding
a total range of -128C to +128C."
::= { acdSfpDiagEntry 3 }
acdSfpDiagVcc OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Internally measured transceiver supply voltage. Represented as
a 16 bit unsigned integer with the voltage defined as the full
16 bit value (0 to 65535) with LSB equal to 100 micro-Volt,
yielding a total range of 0 to +6.55 Volts."
::= { acdSfpDiagEntry 4 }
acdSfpDiagLbc OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured TX bias current in micro-Amps yielding a total range of
0 to 131 mA."
::= { acdSfpDiagEntry 5 }
acdSfpDiagTxPwr OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured TX output power in mW. Represented as a 16 bit unsigned
integer with the power defined as the full 16 bit value (0 to 65535)
with LSB equal to 0.1 micro-Watt, yielding a total range of 0
to 6.5535 mW (~ -40 to +8.2 dBm)."
::= { acdSfpDiagEntry 6 }
acdSfpDiagRxPwr OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured Rx input power in mW. Represented as a 16 bit unsigned
integer with the power defined as the full 16 bit value (0 to 65535)
with LSB equal to 0.1 micro-Watt, yielding a total range of 0
to 6.5535 mW (~ -40 to +8.2 dBm)."
::= { acdSfpDiagEntry 7 }
acdSfpDiagTxPwrdBm OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured TX output power in dBm (~ -40 to +8.2 dBm)."
::= { acdSfpDiagEntry 8 }
acdSfpDiagRxPwrdBm OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured Rx input power in dBm (~ -40 to +8.2 dBm)."
::= { acdSfpDiagEntry 9 }
-----------------------------------------------------------------------
-- The Alarm and Warning Thresholds SFP table
-- This table contains all SFP Alarm and Warning Thresholds.
---------------------------------------------------------------------------
acdSfpThreshTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcdSfpThreshEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of all SFP Alarm and Warning Thresholds"
::= { acdSfp 3 }
acdSfpThreshEntry OBJECT-TYPE
SYNTAX AcdSfpThreshEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" This is a part the content of the SFP's 0xA0 EEPROM"
INDEX { acdSfpThreshID }
::= { acdSfpThreshTable 1 }
AcdSfpThreshEntry ::= SEQUENCE {
acdSfpThreshID Unsigned32,
acdSfpThreshConnIdx Unsigned32,
acdSfpThreshTempHighAlm Integer32,
acdSfpThreshTempLowAlm Integer32,
acdSfpThreshTempHighWarn Integer32,
acdSfpThreshTempLowWarn Integer32,
acdSfpThreshVccHighAlm Unsigned32,
acdSfpThreshVccLowAlm Unsigned32,
acdSfpThreshVccHighWarn Unsigned32,
acdSfpThreshVccLowWarn Unsigned32,
acdSfpThreshLbcHighAlm Unsigned32,
acdSfpThreshLbcLowAlm Unsigned32,
acdSfpThreshLbcHighWarn Unsigned32,
acdSfpThreshLbcLowWarn Unsigned32,
acdSfpThreshTxPwrHighAlm Unsigned32,
acdSfpThreshTxPwrLowAlm Unsigned32,
acdSfpThreshTxPwrHighWarn Unsigned32,
acdSfpThreshTxPwrLowWarn Unsigned32,
acdSfpThreshRxPwrHighAlm Unsigned32,
acdSfpThreshRxPwrLowAlm Unsigned32,
acdSfpThreshRxPwrHighWarn Unsigned32,
acdSfpThreshRxPwrLowWarn Unsigned32,
acdSfpThreshTxPwrHighAlmdBm DisplayString,
acdSfpThreshTxPwrLowAlmdBm DisplayString,
acdSfpThreshTxPwrHighWarndBm DisplayString,
acdSfpThreshTxPwrLowWarndBm DisplayString,
acdSfpThreshRxPwrHighAlmdBm DisplayString,
acdSfpThreshRxPwrLowAlmdBm DisplayString,
acdSfpThreshRxPwrHighWarndBm DisplayString,
acdSfpThreshRxPwrLowWarndBm DisplayString
}
acdSfpThreshID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique value for each SFP. Its value ranges from 1 to
MAXINT (4 bytes). "
::= { acdSfpThreshEntry 1 }
acdSfpThreshConnIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the connector index on the box. The index
is assigned form left to rigth starting with 1."
::= { acdSfpThreshEntry 2 }
acdSfpThreshTempHighAlm OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Alarm transceiver temperature. Represented as a 16 bit
signed twos complement value in degrees Celsius, yielding
a total range of -128C to +128C."
::= { acdSfpThreshEntry 3 }
acdSfpThreshTempLowAlm OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Alarm transceiver temperature. Represented as a 16 bit
signed twos complement value in degrees Celsius, yielding
a total range of -128C to +128C."
::= { acdSfpThreshEntry 4 }
acdSfpThreshTempHighWarn OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Warning transceiver temperature. Represented as a 16 bit
signed twos complement value in degrees Celsius, yielding
a total range of -128C to +128C."
::= { acdSfpThreshEntry 5 }
acdSfpThreshTempLowWarn OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Warning transceiver temperature. Represented as a 16 bit
signed twos complement value in degrees Celsius, yielding
a total range of -128C to +128C."
::= { acdSfpThreshEntry 6 }
acdSfpThreshVccHighAlm OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Alarm transceiver supply voltage. Represented as
a 16 bit unsigned integer with the voltage defined as the full
16 bit value (0 to 65535) with LSB equal to 100 micro-Volt,
yielding a total range of 0 to +6.55 Volts."
::= { acdSfpThreshEntry 7 }
acdSfpThreshVccLowAlm OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Alarm transceiver supply voltage. Represented as
a 16 bit unsigned integer with the voltage defined as the full
16 bit value (0 to 65535) with LSB equal to 100 micro-Volt,
yielding a total range of 0 to +6.55 Volts."
::= { acdSfpThreshEntry 8 }
acdSfpThreshVccHighWarn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Warning transceiver supply voltage. Represented as
a 16 bit unsigned integer with the voltage defined as the full
16 bit value (0 to 65535) with LSB equal to 100 micro-Volt,
yielding a total range of 0 to +6.55 Volts."
::= { acdSfpThreshEntry 9 }
acdSfpThreshVccLowWarn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Warning transceiver supply voltage. Represented as
a 16 bit unsigned integer with the voltage defined as the full
16 bit value (0 to 65535) with LSB equal to 100 micro-Volt,
yielding a total range of 0 to +6.55 Volts."
::= { acdSfpThreshEntry 10 }
acdSfpThreshLbcHighAlm OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Alarm TX bias current in micro-Amps yielding a total range of
0 to 131 mA."
::= { acdSfpThreshEntry 11 }
acdSfpThreshLbcLowAlm OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Alarm TX bias current in micro-Amps yielding a total range of
0 to 131 mA."
::= { acdSfpThreshEntry 12 }
acdSfpThreshLbcHighWarn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Warning TX bias current in micro-Amps yielding a total range of
0 to 131 mA."
::= { acdSfpThreshEntry 13 }
acdSfpThreshLbcLowWarn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Warning TX bias current in micro-Amps yielding a total range of
0 to 131 mA."
::= { acdSfpThreshEntry 14 }
acdSfpThreshTxPwrHighAlm OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Alarm TX output power in mW. Represented as a 16 bit unsigned
integer with the power defined as the full 16 bit value (0 to 65535)
with LSB equal to 0.1 micro-Watt, yielding a total range of 0
to 6.5535 mW (~ -40 to +8.2 dBm)."
::= { acdSfpThreshEntry 15 }
acdSfpThreshTxPwrLowAlm OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Alarm TX output power in mW. Represented as a 16 bit unsigned
integer with the power defined as the full 16 bit value (0 to 65535)
with LSB equal to 0.1 micro-Watt, yielding a total range of 0
to 6.5535 mW (~ -40 to +8.2 dBm)."
::= { acdSfpThreshEntry 16 }
acdSfpThreshTxPwrHighWarn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Warning TX output power in mW. Represented as a 16 bit unsigned
integer with the power defined as the full 16 bit value (0 to 65535)
with LSB equal to 0.1 micro-Watt, yielding a total range of 0
to 6.5535 mW (~ -40 to +8.2 dBm)."
::= { acdSfpThreshEntry 17 }
acdSfpThreshTxPwrLowWarn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Warning TX output power in mW. Represented as a 16 bit unsigned
integer with the power defined as the full 16 bit value (0 to 65535)
with LSB equal to 0.1 micro-Watt, yielding a total range of 0
to 6.5535 mW (~ -40 to +8.2 dBm)."
::= { acdSfpThreshEntry 18 }
acdSfpThreshRxPwrHighAlm OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Alarm RX input power in mW. Represented as a 16 bit unsigned
integer with the power defined as the full 16 bit value (0 to 65535)
with LSB equal to 0.1 micro-Watt, yielding a total range of 0
to 6.5535 mW (~ -40 to +8.2 dBm)."
::= { acdSfpThreshEntry 19 }
acdSfpThreshRxPwrLowAlm OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Alarm RX input power in mW. Represented as a 16 bit unsigned
integer with the power defined as the full 16 bit value (0 to 65535)
with LSB equal to 0.1 micro-Watt, yielding a total range of 0
to 6.5535 mW (~ -40 to +8.2 dBm)."
::= { acdSfpThreshEntry 20 }
acdSfpThreshRxPwrHighWarn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Warning RX input power in mW. Represented as a 16 bit unsigned
integer with the power defined as the full 16 bit value (0 to 65535)
with LSB equal to 0.1 micro-Watt, yielding a total range of 0
to 6.5535 mW (~ -40 to +8.2 dBm)."
::= { acdSfpThreshEntry 21 }
acdSfpThreshRxPwrLowWarn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Warning RX input power in mW. Represented as a 16 bit unsigned
integer with the power defined as the full 16 bit value (0 to 65535)
with LSB equal to 0.1 micro-Watt, yielding a total range of 0
to 6.5535 mW (~ -40 to +8.2 dBm)."
::= { acdSfpThreshEntry 22 }
acdSfpThreshTxPwrHighAlmdBm OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Alarm TX output power in dBm (~ -40 to +8.2 dBm)."
::= { acdSfpThreshEntry 23 }
acdSfpThreshTxPwrLowAlmdBm OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Alarm TX output power in dBm (~ -40 to +8.2 dBm)."
::= { acdSfpThreshEntry 24 }
acdSfpThreshTxPwrHighWarndBm OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Warning TX output power in dBm (~ -40 to +8.2 dBm)."
::= { acdSfpThreshEntry 25 }
acdSfpThreshTxPwrLowWarndBm OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Warning TX output power in dBm (~ -40 to +8.2 dBm)."
::= { acdSfpThreshEntry 26 }
acdSfpThreshRxPwrHighAlmdBm OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Alarm Rx input power in dBm (~ -40 to +8.2 dBm)."
::= { acdSfpThreshEntry 27 }
acdSfpThreshRxPwrLowAlmdBm OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Alarm Rx input power in dBm (~ -40 to +8.2 dBm)."
::= { acdSfpThreshEntry 28 }
acdSfpThreshRxPwrHighWarndBm OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Warning Rx input power in dBm (~ -40 to +8.2 dBm)."
::= { acdSfpThreshEntry 29 }
acdSfpThreshRxPwrLowWarndBm OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Warning Rx input power in dBm (~ -40 to +8.2 dBm)."
::= { acdSfpThreshEntry 30 }
------------------------------------------------------------------------------
-- The Alarm and Warning Thresholds SFP Status table
-- This table contains all statuses for the SFP Alarm and Warning Thresholds.
------------------------------------------------------------------------------
acdSfpThreshStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcdSfpThreshStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of all SFP Digital Diagnostics Thresholds statuses"
::= { acdSfp 4 }
acdSfpThreshStatusEntry OBJECT-TYPE
SYNTAX AcdSfpThreshStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a part the content of the SFP's 0xA2 EEPROM"
INDEX { acdSfpThreshStatusID }
::= { acdSfpThreshStatusTable 1 }
AcdSfpThreshStatusEntry ::= SEQUENCE {
acdSfpThreshStatusID Unsigned32,
acdSfpThreshStatusConnIdx Unsigned32,
acdSfpThreshStatusTempHighAlm TruthValue,
acdSfpThreshStatusTempLowAlm TruthValue,
acdSfpThreshStatusTempHighWarn TruthValue,
acdSfpThreshStatusTempLowWarn TruthValue,
acdSfpThreshStatusVccHighAlm TruthValue,
acdSfpThreshStatusVccLowAlm TruthValue,
acdSfpThreshStatusVccHighWarn TruthValue,
acdSfpThreshStatusVccLowWarn TruthValue,
acdSfpThreshStatusLbcHighAlm TruthValue,
acdSfpThreshStatusLbcLowAlm TruthValue,
acdSfpThreshStatusLbcHighWarn TruthValue,
acdSfpThreshStatusLbcLowWarn TruthValue,
acdSfpThreshStatusTxPwrHighAlm TruthValue,
acdSfpThreshStatusTxPwrLowAlm TruthValue,
acdSfpThreshStatusTxPwrHighWarn TruthValue,
acdSfpThreshStatusTxPwrLowWarn TruthValue,
acdSfpThreshStatusRxPwrHighAlm TruthValue,
acdSfpThreshStatusRxPwrLowAlm TruthValue,
acdSfpThreshStatusRxPwrHighWarn TruthValue,
acdSfpThreshStatusRxPwrLowWarn TruthValue
}
acdSfpThreshStatusID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique value for each SFP. Its value ranges from 1 to
MAXINT (4 bytes). "
::= { acdSfpThreshStatusEntry 1 }
acdSfpThreshStatusConnIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the connector index on the box. The index
is assigned form left to rigth starting with 1."
::= { acdSfpThreshStatusEntry 2 }
acdSfpThreshStatusTempHighAlm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the temperature reaches or overpasses the High
alarm threshold."
::= { acdSfpThreshStatusEntry 3 }
acdSfpThreshStatusTempLowAlm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the temperature reaches or underpasses the Low
alarm threshold."
::= { acdSfpThreshStatusEntry 4 }
acdSfpThreshStatusTempHighWarn OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the temperature reaches or overpasses the High
warning threshold."
::= { acdSfpThreshStatusEntry 5 }
acdSfpThreshStatusTempLowWarn OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the temperature reaches or underpasses the Low
warning threshold."
::= { acdSfpThreshStatusEntry 6 }
acdSfpThreshStatusVccHighAlm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the supply voltage reaches or overpasses the High
alarm threshold."
::= { acdSfpThreshStatusEntry 7 }
acdSfpThreshStatusVccLowAlm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the supply voltage reaches or underpasses the Low
alarm threshold."
::= { acdSfpThreshStatusEntry 8 }
acdSfpThreshStatusVccHighWarn OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the supply voltage reaches or overpasses the High
warning threshold."
::= { acdSfpThreshStatusEntry 9 }
acdSfpThreshStatusVccLowWarn OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the supply voltage reaches or underpasses the Low
warning threshold."
::= { acdSfpThreshStatusEntry 10 }
acdSfpThreshStatusLbcHighAlm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the Laser Bias Current reaches or overpasses
the High alarm threshold."
::= { acdSfpThreshStatusEntry 11 }
acdSfpThreshStatusLbcLowAlm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the Laser Bias Current reaches or underpasses
the Low alarm threshold."
::= { acdSfpThreshStatusEntry 12 }
acdSfpThreshStatusLbcHighWarn OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the Laser Bias Current reaches or overpasses
the High warning threshold."
::= { acdSfpThreshStatusEntry 13 }
acdSfpThreshStatusLbcLowWarn OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the Laser Bias Current reaches or underpasses
the Low warning threshold."
::= { acdSfpThreshStatusEntry 14 }
acdSfpThreshStatusTxPwrHighAlm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the Transmit Power reaches or overpasses the High
alarm threshold."
::= { acdSfpThreshStatusEntry 15 }
acdSfpThreshStatusTxPwrLowAlm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the Transmit Power reaches or underpasses the Low
alarm threshold."
::= { acdSfpThreshStatusEntry 16 }
acdSfpThreshStatusTxPwrHighWarn OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the Transmit Power reaches or overpasses the High
warning threshold."
::= { acdSfpThreshStatusEntry 17 }
acdSfpThreshStatusTxPwrLowWarn OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the Transmit Power reaches or underpasses the Low
warning threshold."
::= { acdSfpThreshStatusEntry 18 }
acdSfpThreshStatusRxPwrHighAlm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the Receive Power reaches or overpasses the High
alarm threshold."
::= { acdSfpThreshStatusEntry 19 }
acdSfpThreshStatusRxPwrLowAlm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the Receive Power reaches or underpasses the Low
alarm threshold."
::= { acdSfpThreshStatusEntry 20 }
acdSfpThreshStatusRxPwrHighWarn OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the Receive Power reaches or overpasses the High
warning threshold."
::= { acdSfpThreshStatusEntry 21 }
acdSfpThreshStatusRxPwrLowWarn OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the Receive Power reaches or underpasses the Low
warning threshold."
::= { acdSfpThreshStatusEntry 22 }
---------------------------------------------------------------------------
-- ACD-SFP-MIB Module - Conformance Information
---------------------------------------------------------------------------
acdSfpCompliances OBJECT IDENTIFIER ::= { acdSfpConformance 1 }
acdSfpGroups OBJECT IDENTIFIER ::= { acdSfpConformance 2 }
---------------------------------------------------------------------------
-- Units of conformance
---------------------------------------------------------------------------
acdSfpInfoGroup OBJECT-GROUP
OBJECTS {
acdSfpInfoConnIdx,
acdSfpInfoConnType,
acdSfpInfoVendor,
acdSfpInfoVendorOui,
acdSfpInfoVendorPn,
acdSfpInfoVendorRev,
acdSfpInfoWavelength,
acdSfpInfoSerialNum,
acdSfpInfoYear,
acdSfpInfoMonth,
acdSfpInfoDay,
acdSfpInfoLot,
acdSfpInfoRev8472,
acdSfpInfoPresent,
acdSfpInfoDiag,
acdSfpInfoInternal,
acdSfpInfoAlm,
acdSfpInfoIdType,
acdSfpInfoExtIdType,
acdSfpInfoTransCode
}
STATUS current
DESCRIPTION
"Objects for the SFP information Group."
::= { acdSfpGroups 1 }
acdSfpDiagGroup OBJECT-GROUP
OBJECTS {
acdSfpDiagConnIdx,
acdSfpDiagTemp,
acdSfpDiagVcc,
acdSfpDiagLbc,
acdSfpDiagTxPwr,
acdSfpDiagRxPwr,
acdSfpDiagTxPwrdBm,
acdSfpDiagRxPwrdBm
}
STATUS current
DESCRIPTION
"Objects for the SFP diagnostics Group."
::= { acdSfpGroups 2 }
acdSfpThreshGroup OBJECT-GROUP
OBJECTS {
acdSfpThreshConnIdx,
acdSfpThreshTempHighAlm,
acdSfpThreshTempLowAlm,
acdSfpThreshTempHighWarn,
acdSfpThreshTempLowWarn,
acdSfpThreshVccHighAlm,
acdSfpThreshVccLowAlm,
acdSfpThreshVccHighWarn,
acdSfpThreshVccLowWarn,
acdSfpThreshLbcHighAlm,
acdSfpThreshLbcLowAlm,
acdSfpThreshLbcHighWarn,
acdSfpThreshLbcLowWarn,
acdSfpThreshTxPwrHighAlm,
acdSfpThreshTxPwrLowAlm,
acdSfpThreshTxPwrHighWarn,
acdSfpThreshTxPwrLowWarn,
acdSfpThreshRxPwrHighAlm,
acdSfpThreshRxPwrLowAlm,
acdSfpThreshRxPwrHighWarn,
acdSfpThreshRxPwrLowWarn,
acdSfpThreshTxPwrHighAlmdBm,
acdSfpThreshTxPwrLowAlmdBm,
acdSfpThreshTxPwrHighWarndBm,
acdSfpThreshTxPwrLowWarndBm,
acdSfpThreshRxPwrHighAlmdBm,
acdSfpThreshRxPwrLowAlmdBm,
acdSfpThreshRxPwrHighWarndBm,
acdSfpThreshRxPwrLowWarndBm
}
STATUS current
DESCRIPTION
"Objects for the SFP thresholds Group."
::= { acdSfpGroups 3 }
acdSfpThreshStatusGroup OBJECT-GROUP
OBJECTS {
acdSfpThreshStatusConnIdx,
acdSfpThreshStatusTempHighAlm,
acdSfpThreshStatusTempLowAlm,
acdSfpThreshStatusTempHighWarn,
acdSfpThreshStatusTempLowWarn,
acdSfpThreshStatusVccHighAlm,
acdSfpThreshStatusVccLowAlm,
acdSfpThreshStatusVccHighWarn,
acdSfpThreshStatusVccLowWarn,
acdSfpThreshStatusLbcHighAlm,
acdSfpThreshStatusLbcLowAlm,
acdSfpThreshStatusLbcHighWarn,
acdSfpThreshStatusLbcLowWarn,
acdSfpThreshStatusTxPwrHighAlm,
acdSfpThreshStatusTxPwrLowAlm,
acdSfpThreshStatusTxPwrHighWarn,
acdSfpThreshStatusTxPwrLowWarn,
acdSfpThreshStatusRxPwrHighAlm,
acdSfpThreshStatusRxPwrLowAlm,
acdSfpThreshStatusRxPwrHighWarn,
acdSfpThreshStatusRxPwrLowWarn
}
STATUS current
DESCRIPTION
"Objects for the SFP threshold status Group."
::= { acdSfpGroups 4 }
acdSfpCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for support of the ACD-SFP-MIB module."
MODULE
MANDATORY-GROUPS {
acdSfpInfoGroup,
acdSfpDiagGroup,
acdSfpThreshGroup,
acdSfpThreshStatusGroup
}
::= { acdSfpCompliances 1 }
END