F3-CONNECTGUARD-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, IpAddress
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
DateAndTime, DisplayString, TruthValue, RowStatus, StorageType,
MacAddress, VariablePointer, TEXTUAL-CONVENTION, TimeStamp
FROM SNMPv2-TC
Ipv6Address
FROM IPV6-TC
InterfaceIndex, ifIndex
FROM IF-MIB
SecySCI
FROM IEEE8021-SECY-MIB
PhysicalIndex
FROM ENTITY-MIB
neIndex, shelfIndex, slotIndex, f3UsbHostIndex, networkElementEntry
FROM CM-ENTITY-MIB
cmFlowEntry
FROM CM-FACILITY-MIB
f3AccFlowPointEntry
FROM F3-FPM-MIB
f3NetFlowPointEntry
FROM F3-FPM-MIB
fsp150cm
FROM ADVA-MIB
AdminState, OperationalState, SecondaryState, EthernetMediaType,
EthernetPortSpeed, TrafficDirection, SfpConnectorValue, SfpMediaType,
VlanId, VlanPriority, VlanTagType, PriorityMapMode, PerfCounter64,
AfpTagControl, VlanEthertype,CmPmIntervalType, CmPmBinAction,
F3DisplayString
FROM CM-COMMON-MIB;
f3ConnectGuardMIB MODULE-IDENTITY
LAST-UPDATED "201607110000Z"
ORGANIZATION "ADVA Optical Networking"
CONTACT-INFO
" Jack Chen
ADVA Optical Networking, Inc.
Tel: +86755 86217400-8205
E-mail: jchen@advaoptical.com
Postal:
"
DESCRIPTION
"This module defines the Connect Guard MIB definitions used by
the F3 (FSP150CM/CC) product lines.
Copyright (C) ADVA Optical Networking."
REVISION "201607110000Z"
DESCRIPTION
"Notes from release 201607110000Z
a) added FlowSecureState back to the mib since the mib has been released
Notes from release 201607080000Z
a) deprecated f3FlowExtConnectGuardTable moved the attributes to cmFlowTable
b) removed f3AccFlowpointExtConnectGuardTable and f3NetFlowpointExtConnectGuardTable
and moved the attributes to acc/net flowpoint tables
Notes from release 201606200000Z
a) added f3ConnectGuardFlowKeyInjectFlowPoint to f3ConnectGuardFlowTable
Notes from release 201606170000Z
a) added f3MPFlowExtConnectGuardTable
Notes from release 201606060000Z
a) added f3ConnectGuardFlowKeyExchangeFrameOuterVlanEtherType, f3ConnectGuardFlowKeyExchangeFrameInner1VlanEtherType,
and f3ConnectGuardFlowKeyExchangeFrameInner2VlanEtherType to f3ConnectGuardFlowTable
Notes from release 201605100000Z
a) added f3AccFlowpointExtConnectGuardTable and f3NetFlowpointExtConnectGuardTable
to support secure flow on flow point
Notes from release 201604120000Z
a) added system level scalar f3ConnectGuardCryptoPasswordControl
Notes from release 201601260000Z
a) add f3ConnectGuardFlowAlias to f3ConnectGuardFlowTable
Notes from release 201409120000Z
Notes from release 201601040000Z
a) add f3ConnectGuardFlowAssociatedMep to f3ConnectGuardFlowTable
"
::= {fsp150cm 36}
--
-- OID definitions
--
f3ConnectGuardConfigObjects OBJECT IDENTIFIER ::= {f3ConnectGuardMIB 1}
f3ConnectGuardPerformanceObjects OBJECT IDENTIFIER ::= {f3ConnectGuardMIB 2}
f3ConnectGuardNotifications OBJECT IDENTIFIER ::= {f3ConnectGuardMIB 3}
f3ConnectGuardConformance OBJECT IDENTIFIER ::= {f3ConnectGuardMIB 4}
FlowSecureState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Flow secure state."
SYNTAX INTEGER {
secureNormal (1),
secureBlocked (2),
unsecureNormal (3),
unsecureBlocked (4)
}
CipherSuiteType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This object describes the cipher suite type."
SYNTAX INTEGER {
gcmAes256(1),
gcmAes128(2)
}
KeyExchangeFrameTagControl ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This object describes the key exchange frame tag mode."
SYNTAX INTEGER {
autoSelect(1),
manual(2)
}
ScSaState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This object describes the SC State."
SYNTAX INTEGER {
inUse(1),
notInUse(2)
}
ConnectGuardKeyExMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This object describes the Connect Guard Key exchange mode."
SYNTAX INTEGER {
authPasswordBasedDiffieHellman(1),
caBasedDiffieHellman(2),
ieee8021x(3)
}
DiffieHellmanKeyPairLength ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This object describes supported length used in DiffieHellman algorithm."
SYNTAX INTEGER {
length2048(1),
length4096(2)
}
ConnectGuardFlowActionType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The action on mac sec flow."
SYNTAX INTEGER {
noAction (1),
restartKeyXchg (2)
}
--
-- Connect Guard Flow Table
--
f3ConnectGuardFlowTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3ConnectGuardFlowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of entries for the Connect Guard flow."
::= { f3ConnectGuardConfigObjects 1 }
f3ConnectGuardFlowEntry OBJECT-TYPE
SYNTAX F3ConnectGuardFlowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3ConnectGuardFlowTable."
INDEX { neIndex, f3ConnectGuardFlowIndex }
::= { f3ConnectGuardFlowTable 1 }
F3ConnectGuardFlowEntry ::= SEQUENCE {
f3ConnectGuardFlowIndex Integer32,
f3ConnectGuardFlowCipherSuite CipherSuiteType,
f3ConnectGuardFlowAdminState AdminState,
f3ConnectGuardFlowSecondaryState SecondaryState,
f3ConnectGuardFlowOperationalState OperationalState,
f3ConnectGuardFlowEgressInterface VariablePointer,
f3ConnectGuardFlowKeyExchangeProfile VariablePointer,
f3ConnectGuardFlowKeyExchangeFrameTagControl KeyExchangeFrameTagControl,
f3ConnectGuardFlowKeyExchangeFrameOuterVlanEnabled TruthValue,
f3ConnectGuardFlowKeyExchangeFrameOuterVlanId VlanId,
f3ConnectGuardFlowKeyExchangeFrameOuterVlanPriority VlanPriority,
f3ConnectGuardFlowKeyExchangeFrameInner1VlanEnabled TruthValue,
f3ConnectGuardFlowKeyExchangeFrameInner1VlanId VlanId,
f3ConnectGuardFlowKeyExchangeFrameInner1VlanPriority VlanPriority,
f3ConnectGuardFlowKeyExchangeFrameInner2VlanEnabled TruthValue,
f3ConnectGuardFlowKeyExchangeFrameInner2VlanId VlanId,
f3ConnectGuardFlowKeyExchangeFrameInner2VlanPriority VlanPriority,
f3ConnectGuardFlowKeyExchangeInterval Integer32,
f3ConnectGuardFlowTagsClear Integer32,
f3ConnectGuardFlowStorageType StorageType,
f3ConnectGuardFlowRowStatus RowStatus,
f3ConnectGuardFlowKeyXchgFailsCounts Unsigned32,
f3ConnectGuardFlowAction ConnectGuardFlowActionType,
f3ConnectGuardFlowReplayProtectionEnabled TruthValue,
f3ConnectGuardFlowReplayProtectionWindow Unsigned32,
f3ConnectGuardFlowRemoteMacAddrEnabled TruthValue,
f3ConnectGuardFlowRemoteMacAddr MacAddress,
f3ConnectGuardFlowAssociatedMep VariablePointer,
f3ConnectGuardFlowAlias DisplayString,
f3ConnectGuardFlowKeyExchangeFrameOuterVlanEtherType Unsigned32,
f3ConnectGuardFlowKeyExchangeFrameInner1VlanEtherType Unsigned32,
f3ConnectGuardFlowKeyExchangeFrameInner2VlanEtherType Unsigned32,
f3ConnectGuardFlowKeyInjectFlowPoint VariablePointer
}
f3ConnectGuardFlowIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the Connect Guard flow entry."
::= { f3ConnectGuardFlowEntry 1 }
f3ConnectGuardFlowCipherSuite OBJECT-TYPE
SYNTAX CipherSuiteType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the cipher suite type for this flow."
::= { f3ConnectGuardFlowEntry 2 }
f3ConnectGuardFlowAdminState OBJECT-TYPE
SYNTAX AdminState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the Administrative State of the Flow."
::= { f3ConnectGuardFlowEntry 3 }
f3ConnectGuardFlowSecondaryState OBJECT-TYPE
SYNTAX SecondaryState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the Secondary State of the Flow."
::= { f3ConnectGuardFlowEntry 4 }
f3ConnectGuardFlowOperationalState OBJECT-TYPE
SYNTAX OperationalState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the Operational State of the Flow."
::= { f3ConnectGuardFlowEntry 5 }
f3ConnectGuardFlowEgressInterface OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Connect Guard Flow egress interface."
::= { f3ConnectGuardFlowEntry 6 }
f3ConnectGuardFlowKeyExchangeProfile OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the key exchange profile to be used for the secure flow."
::= { f3ConnectGuardFlowEntry 7 }
f3ConnectGuardFlowKeyExchangeFrameTagControl OBJECT-TYPE
SYNTAX KeyExchangeFrameTagControl
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the key exchange frame tag mode."
::= { f3ConnectGuardFlowEntry 8 }
f3ConnectGuardFlowKeyExchangeFrameOuterVlanEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the key exchange frame Outer Vlan."
::= { f3ConnectGuardFlowEntry 9 }
f3ConnectGuardFlowKeyExchangeFrameOuterVlanId OBJECT-TYPE
SYNTAX VlanId
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the key exchange frame outer Vlan ID"
::= { f3ConnectGuardFlowEntry 10 }
f3ConnectGuardFlowKeyExchangeFrameOuterVlanPriority OBJECT-TYPE
SYNTAX VlanPriority
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the key exchange frame outer Vlan Priority."
::= { f3ConnectGuardFlowEntry 11 }
f3ConnectGuardFlowKeyExchangeFrameInner1VlanEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the key exchange frame Inner Vlan."
::= { f3ConnectGuardFlowEntry 12 }
f3ConnectGuardFlowKeyExchangeFrameInner1VlanId OBJECT-TYPE
SYNTAX VlanId
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the key exchange frame Inner Vlan ID"
::= { f3ConnectGuardFlowEntry 13 }
f3ConnectGuardFlowKeyExchangeFrameInner1VlanPriority OBJECT-TYPE
SYNTAX VlanPriority
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the key exchange frame Inner Vlan Priority."
::= { f3ConnectGuardFlowEntry 14 }
f3ConnectGuardFlowKeyExchangeFrameInner2VlanEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the key exchange frame Inner most Vlan."
::= { f3ConnectGuardFlowEntry 15 }
f3ConnectGuardFlowKeyExchangeFrameInner2VlanId OBJECT-TYPE
SYNTAX VlanId
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the key exchange frame Inner most Vlan ID"
::= { f3ConnectGuardFlowEntry 16 }
f3ConnectGuardFlowKeyExchangeFrameInner2VlanPriority OBJECT-TYPE
SYNTAX VlanPriority
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the key exchange frame Inner most Vlan Priority."
::= { f3ConnectGuardFlowEntry 17 }
f3ConnectGuardFlowKeyExchangeInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the key exchange interval value, in one minute increment"
::= { f3ConnectGuardFlowEntry 18 }
f3ConnectGuardFlowTagsClear OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the number of tags to by pass in encryption"
::= { f3ConnectGuardFlowEntry 19 }
f3ConnectGuardFlowStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of storage configured for this entry."
::= { f3ConnectGuardFlowEntry 20 }
f3ConnectGuardFlowRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this row.
An entry MUST NOT exist in the active state unless all
objects in the entry have an appropriate value, as described
in the description clause for each writable object.
The values of f3ConnectGuardFlowRowStatus supported are
createAndGo(4) and destroy(6). All mandatory attributes
must be specified in a single SNMP SET request with
f3ConnectGuardFlowRowStatus value as createAndGo(4).
Upon successful row creation, this variable has a
value of active(1).
The f3ConnectGuardFlowRowStatus object may be modified if
the associated instance of this object is equal to active(1)."
::= { f3ConnectGuardFlowEntry 21 }
f3ConnectGuardFlowKeyXchgFailsCounts OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object counts number of times key exchange protocol failed."
::= { f3ConnectGuardFlowEntry 22 }
f3ConnectGuardFlowAction OBJECT-TYPE
SYNTAX ConnectGuardFlowActionType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object describe operation on the Connect Guard flow."
::= { f3ConnectGuardFlowEntry 23 }
f3ConnectGuardFlowReplayProtectionEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object can be used to enable/disable replay proctection."
::= { f3ConnectGuardFlowEntry 24 }
f3ConnectGuardFlowReplayProtectionWindow OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines replay proctection window value."
::= { f3ConnectGuardFlowEntry 25 }
f3ConnectGuardFlowRemoteMacAddrEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object can be used to enable/disable remote MAC Address that used as the destination MAC address in the
key exchange protocol packets."
::= { f3ConnectGuardFlowEntry 26 }
f3ConnectGuardFlowRemoteMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines remote MAC Address value."
::= { f3ConnectGuardFlowEntry 27 }
f3ConnectGuardFlowAssociatedMep OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object speicify the mep object to use as trigger for key exchange failure"
::= { f3ConnectGuardFlowEntry 28 }
f3ConnectGuardFlowAlias OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object speicify the connect guard flow's alias."
::= { f3ConnectGuardFlowEntry 29 }
f3ConnectGuardFlowKeyExchangeFrameOuterVlanEtherType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Outer vlan ether type used in key exchange."
::= { f3ConnectGuardFlowEntry 30 }
f3ConnectGuardFlowKeyExchangeFrameInner1VlanEtherType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Inner1 vlan ether type used in key exchange."
::= { f3ConnectGuardFlowEntry 31 }
f3ConnectGuardFlowKeyExchangeFrameInner2VlanEtherType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Inner2 vlan ether type used in key exchange."
::= { f3ConnectGuardFlowEntry 32 }
f3ConnectGuardFlowKeyInjectFlowPoint OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Pointer to a flowpoint used to up inject key exchange frames in case of ERP."
::= { f3ConnectGuardFlowEntry 33 }
--
-- Key Exchange Profile Table
--
f3ConnectGuardKeyExchangeProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3ConnectGuardKeyExchangeProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of entries for the key exchange profile."
::= { f3ConnectGuardConfigObjects 2 }
f3ConnectGuardKeyExchangeProfileEntry OBJECT-TYPE
SYNTAX F3ConnectGuardKeyExchangeProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3ConnectGuardKeyExchangeProfileTable."
INDEX { f3ConnectGuardKeyExchangeProfileIndex }
::= { f3ConnectGuardKeyExchangeProfileTable 1 }
F3ConnectGuardKeyExchangeProfileEntry ::= SEQUENCE {
f3ConnectGuardKeyExchangeProfileIndex Integer32,
f3ConnectGuardKeyExchangeProfileName DisplayString,
f3ConnectGuardKeyExchangeProfileUserId DisplayString,
f3ConnectGuardKeyExchangeProfileMode ConnectGuardKeyExMode,
f3ConnectGuardKeyExchangeProfileAuthPassword DisplayString,
f3ConnectGuardKeyExchangeProfileDiffieHellmanKeyPairLen DiffieHellmanKeyPairLength,
f3ConnectGuardKeyExchangeProfileStorageType StorageType,
f3ConnectGuardKeyExchangeProfileRowStatus RowStatus
}
f3ConnectGuardKeyExchangeProfileIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the key exchange profile."
::= { f3ConnectGuardKeyExchangeProfileEntry 1 }
f3ConnectGuardKeyExchangeProfileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of this profile."
::= { f3ConnectGuardKeyExchangeProfileEntry 2 }
f3ConnectGuardKeyExchangeProfileUserId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user name who created this profile. It is automatically set by the system."
::= { f3ConnectGuardKeyExchangeProfileEntry 3 }
f3ConnectGuardKeyExchangeProfileMode OBJECT-TYPE
SYNTAX ConnectGuardKeyExMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The key exchange mode."
::= { f3ConnectGuardKeyExchangeProfileEntry 4 }
f3ConnectGuardKeyExchangeProfileAuthPassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The authentication password for this profile."
::= { f3ConnectGuardKeyExchangeProfileEntry 5 }
f3ConnectGuardKeyExchangeProfileDiffieHellmanKeyPairLen OBJECT-TYPE
SYNTAX DiffieHellmanKeyPairLength
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Diffie-Hellman key pair length for this profile."
::= { f3ConnectGuardKeyExchangeProfileEntry 6 }
f3ConnectGuardKeyExchangeProfileStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of storage configured for this entry."
::= { f3ConnectGuardKeyExchangeProfileEntry 7 }
f3ConnectGuardKeyExchangeProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this row.
An entry MUST NOT exist in the active state unless all
objects in the entry have an appropriate value, as described
in the description clause for each writable object.
The values of f3ConnectGuardKeyExchangeProfileRowStatus supported are
createAndGo(4) and destroy(6). All mandatory attributes
must be specified in a single SNMP SET request with
f3ConnectGuardKeyExchangeProfileRowStatus value as createAndGo(4).
Upon successful row creation, this variable has a
value of active(1).
The f3ConnectGuardKeyExchangeProfileRowStatus object may be modified if
the associated instance of this object is equal to active(1)."
::= { f3ConnectGuardKeyExchangeProfileEntry 8 }
--
-- TX SC Table
--
f3ConnectGuardTxSCTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3ConnectGuardTxSCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of entries for the Connect Guard TX SC."
::= { f3ConnectGuardConfigObjects 3 }
f3ConnectGuardTxSCEntry OBJECT-TYPE
SYNTAX F3ConnectGuardTxSCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3ConnectGuardTxSCTable."
INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardTxSCIndex }
::= { f3ConnectGuardTxSCTable 1 }
F3ConnectGuardTxSCEntry ::= SEQUENCE {
f3ConnectGuardTxSCIndex Integer32,
f3ConnectGuardTxSCI SecySCI,
f3ConnectGuardTxScState ScSaState,
f3ConnectGuardCurrentTxSa Integer32,
f3ConnectGuardPreviousTxSa Integer32,
f3ConnectGuardTxScCreateTime DateAndTime,
f3ConnectGuardTxScStartTime DateAndTime,
f3ConnectGuardTxScStopTime DateAndTime
}
f3ConnectGuardTxSCIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the Connect Guard TX SC entry."
::= { f3ConnectGuardTxSCEntry 1 }
f3ConnectGuardTxSCI OBJECT-TYPE
SYNTAX SecySCI
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the Connect Guard TX SCI."
::= { f3ConnectGuardTxSCEntry 2 }
f3ConnectGuardTxScState OBJECT-TYPE
SYNTAX ScSaState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines the Tx Sc State."
::= { f3ConnectGuardTxSCEntry 3 }
f3ConnectGuardCurrentTxSa OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines the AN number of current Tx SA.
-1 means no current Tx SA."
::= { f3ConnectGuardTxSCEntry 4 }
f3ConnectGuardPreviousTxSa OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines the AN number of previous Tx SA.
-1 means no previous Tx SA."
::= { f3ConnectGuardTxSCEntry 5 }
f3ConnectGuardTxScCreateTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines the system time when the SC was created."
::= { f3ConnectGuardTxSCEntry 6 }
f3ConnectGuardTxScStartTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system time when this transmitting SC last started
transmitting Connect Guard frames."
::= { f3ConnectGuardTxSCEntry 7 }
f3ConnectGuardTxScStopTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system time when this transmitting SC last stopped
transmitting Connect Guard frames."
::= { f3ConnectGuardTxSCEntry 8}
--
-- RX SC Table
--
f3ConnectGuardRxSCTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3ConnectGuardRxSCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of entries for the Connect Guard RX SC."
::= { f3ConnectGuardConfigObjects 4 }
f3ConnectGuardRxSCEntry OBJECT-TYPE
SYNTAX F3ConnectGuardRxSCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3ConnectGuardRxSCTable."
INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardRxSCIndex }
::= { f3ConnectGuardRxSCTable 1 }
F3ConnectGuardRxSCEntry ::= SEQUENCE {
f3ConnectGuardRxSCIndex Integer32,
f3ConnectGuardRxSCI SecySCI,
f3ConnectGuardRxScState ScSaState,
f3ConnectGuardCurrentRxSa Integer32,
f3ConnectGuardRxScCreateTime DateAndTime,
f3ConnectGuardRxScStartTime DateAndTime,
f3ConnectGuardRxScStopTime DateAndTime
}
f3ConnectGuardRxSCIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The RX SC number."
::= { f3ConnectGuardRxSCEntry 1 }
f3ConnectGuardRxSCI OBJECT-TYPE
SYNTAX SecySCI
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SCI value, includes 8 bytes."
::= { f3ConnectGuardRxSCEntry 2 }
f3ConnectGuardRxScState OBJECT-TYPE
SYNTAX ScSaState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of the receiving SC in the SecY.
inUse(1) : means any of SAs for this SC is in use.
notInUse(2) : means no SAs for this SC is in use."
::= { f3ConnectGuardRxSCEntry 3}
f3ConnectGuardCurrentRxSa OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The AN number of current Rx SA, -1 means no current Rx SA."
::= { f3ConnectGuardRxSCEntry 4}
f3ConnectGuardRxScCreateTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system time when this receiving SC was created."
::= { f3ConnectGuardRxSCEntry 5 }
f3ConnectGuardRxScStartTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system time when this receiving SC last started
receiving ConnectGuard frames."
::= { f3ConnectGuardRxSCEntry 6 }
f3ConnectGuardRxScStopTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system time when this receiving SC last stopped
receiving ConnectGuard frames."
::= { f3ConnectGuardRxSCEntry 7}
--
-- Tx SA Management Table
--
f3ConnectGuardTxSATable OBJECT-TYPE
SYNTAX SEQUENCE OF F3ConnectGuardTxSAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table for providing information about the status of each
transmitting SA supported by the MAC security entity."
REFERENCE
"IEEE 802.1AE Clause 10.7.21"
::= { f3ConnectGuardConfigObjects 5 }
f3ConnectGuardTxSAEntry OBJECT-TYPE
SYNTAX F3ConnectGuardTxSAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing transmitting SA management information
applicable to a particular SA."
INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardTxSCIndex, f3ConnectGuardTxSAIndex }
::= { f3ConnectGuardTxSATable 1 }
F3ConnectGuardTxSAEntry ::= SEQUENCE {
f3ConnectGuardTxSAIndex Unsigned32,
f3ConnectGuardTxSAState INTEGER,
f3ConnectGuardTxSANextPN Unsigned32,
f3ConnectGuardTxSASAKUnchanged TruthValue,
f3ConnectGuardTxSACreatedTime DateAndTime,
f3ConnectGuardTxSAStartedTime DateAndTime,
f3ConnectGuardTxSAStoppedTime DateAndTime
}
f3ConnectGuardTxSAIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The association number (AN) for identifying a transmitting
SA."
REFERENCE
"IEEE 802.1AE Clause 10.7.21"
::= { f3ConnectGuardTxSAEntry 1 }
f3ConnectGuardTxSAState OBJECT-TYPE
SYNTAX ScSaState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of the transmitting SA.
inUse(1) : means this SA is in use.
notInUse(2) : means this SA is not in use."
REFERENCE
"IEEE 802.1AE Clause 10.7.22"
::= { f3ConnectGuardTxSAEntry 2 }
f3ConnectGuardTxSANextPN OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The next packet number (PN) that will be used in transmitting
ConnectGuard frames in the SA."
REFERENCE
"IEEE 802.1AE Clause 10.7.21"
::= { f3ConnectGuardTxSAEntry 3 }
f3ConnectGuardTxSASAKUnchanged OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to an SAK that is unchanged for the life
of the transmitting SA."
REFERENCE
"IEEE 802.1AE Clause 10.7.21"
::= { f3ConnectGuardTxSAEntry 4 }
f3ConnectGuardTxSACreatedTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system time when this transmitting SA was created."
REFERENCE
"IEEE 802.1AE Clause 10.7.22"
::= { f3ConnectGuardTxSAEntry 5 }
f3ConnectGuardTxSAStartedTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system time when this transmitting SA last started
transmitting ConnectGuard frames."
REFERENCE
"IEEE 802.1AE Clause 10.7.22"
::= { f3ConnectGuardTxSAEntry 6 }
f3ConnectGuardTxSAStoppedTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system time when this transmitting SA last stopped
transmitting ConnectGuard frames."
REFERENCE
"IEEE 802.1AE Clause 10.7.22"
::= { f3ConnectGuardTxSAEntry 7 }
--
-- Rx SA Management Table
--
f3ConnectGuardRxSATable OBJECT-TYPE
SYNTAX SEQUENCE OF F3ConnectGuardRxSAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table for providing information about the status of each
transmitting SA supported by the MAC security entity."
REFERENCE
"IEEE 802.1AE Clause 10.7.21"
::= { f3ConnectGuardConfigObjects 6 }
f3ConnectGuardRxSAEntry OBJECT-TYPE
SYNTAX F3ConnectGuardRxSAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing transmitting SA management information
applicable to a particular SA."
INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardRxSCIndex, f3ConnectGuardRxSAIndex }
::= { f3ConnectGuardRxSATable 1 }
F3ConnectGuardRxSAEntry ::= SEQUENCE {
f3ConnectGuardRxSAIndex Unsigned32,
f3ConnectGuardRxSAState INTEGER,
f3ConnectGuardRxSANextPN Unsigned32,
f3ConnectGuardRxSASAKUnchanged TruthValue,
f3ConnectGuardRxSACreatedTime DateAndTime,
f3ConnectGuardRxSAStartedTime DateAndTime,
f3ConnectGuardRxSAStoppedTime DateAndTime
}
f3ConnectGuardRxSAIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The association number (AN) for identifying a transmitting
SA."
REFERENCE
"IEEE 802.1AE Clause 10.7.21"
::= { f3ConnectGuardRxSAEntry 1 }
f3ConnectGuardRxSAState OBJECT-TYPE
SYNTAX ScSaState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of the transmitting SA.
inUse(1) : means this SA is in use.
notInUse(2) : means this SA is not in use."
REFERENCE
"IEEE 802.1AE Clause 10.7.22"
::= { f3ConnectGuardRxSAEntry 2 }
f3ConnectGuardRxSANextPN OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The next packet number (PN) that will be used in transmitting
ConnectGuard frames in the SA."
REFERENCE
"IEEE 802.1AE Clause 10.7.21"
::= { f3ConnectGuardRxSAEntry 3 }
f3ConnectGuardRxSASAKUnchanged OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to an SAK that is unchanged for the life
of the transmitting SA."
REFERENCE
"IEEE 802.1AE Clause 10.7.21"
::= { f3ConnectGuardRxSAEntry 4 }
f3ConnectGuardRxSACreatedTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system time when this transmitting SA was created."
REFERENCE
"IEEE 802.1AE Clause 10.7.22"
::= { f3ConnectGuardRxSAEntry 5 }
f3ConnectGuardRxSAStartedTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system time when this transmitting SA last started
transmitting ConnectGuard frames."
REFERENCE
"IEEE 802.1AE Clause 10.7.22"
::= { f3ConnectGuardRxSAEntry 6 }
f3ConnectGuardRxSAStoppedTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system time when this transmitting SA last stopped
transmitting ConnectGuard frames."
REFERENCE
"IEEE 802.1AE Clause 10.7.22"
::= { f3ConnectGuardRxSAEntry 7 }
--
-- flow extension Table
--
f3FlowExtConnectGuardTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3FlowExtConnectGuardEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A list of entries corresponding to Flow for configuration purposes.
This table has been deprecated. Attributes have been moved to
cmFlowTable."
::= { f3ConnectGuardConfigObjects 7 }
f3FlowExtConnectGuardEntry OBJECT-TYPE
SYNTAX F3FlowExtConnectGuardEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A conceptual row in the f3FlowExtConnectGuardTable."
AUGMENTS { cmFlowEntry }
::= { f3FlowExtConnectGuardTable 1 }
F3FlowExtConnectGuardEntry ::= SEQUENCE {
f3FlowRefConnectGuardFlowObject VariablePointer,
f3FlowSecureBlockingEnabled TruthValue,
f3FlowSecureState FlowSecureState
}
f3FlowRefConnectGuardFlowObject OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies Mac Sec flow object OID."
::= { f3FlowExtConnectGuardEntry 1 }
f3FlowSecureBlockingEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object can be used to enable/disable secure block."
::= { f3FlowExtConnectGuardEntry 2 }
f3FlowSecureState OBJECT-TYPE
SYNTAX FlowSecureState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the secure state of this flow."
::= { f3FlowExtConnectGuardEntry 3 }
f3ConnectGuardConfigScalars OBJECT IDENTIFIER ::= {f3ConnectGuardConfigObjects 8}
f3ConnectGuardPasswordScalars OBJECT IDENTIFIER ::= {f3ConnectGuardConfigObjects 9}
f3ConnectGuardCryptoPassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the second level password for the crypto user.
This password is required to modify ConnectGuard objects.
Every set request that involves a ConnectGuard object should
include this variable with correct password value to succeed."
::= { f3ConnectGuardPasswordScalars 1 }
f3ConnectGuardRestoreFactoryApproved OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Crypto user can use this object to enable/disable restore factory defaults on the NID."
::= { f3ConnectGuardConfigScalars 1 }
f3ConnectGuardSoftwareVersionApproved OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object describes the software version that crypto user approved for upgrade."
::= { f3ConnectGuardConfigScalars 2 }
f3ConnectGuardSoftwareInstallApproved OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Crypto user can use this object to enable/disable sofware install on the NID."
::= { f3ConnectGuardConfigScalars 3 }
f3ConnectGuardRestoreDatabaseApproved OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Crypto user can use this object to enable/disable restore database on the NID."
::= { f3ConnectGuardConfigScalars 4 }
f3ConnectGuardConfigFileLoadApproved OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Crypto user can use this object to enable/disable config file operation on the NID."
::= { f3ConnectGuardConfigScalars 5 }
f3ConnectGuardCryptoPasswordControl OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A system level attribute to disable/enable crypto password request when changing ConnectGuard attributes."
::= { f3ConnectGuardConfigScalars 6 }
--
-- PERFORMANCE
--
--
-- Mac Sec Flow Current Statistics Table
--
f3ConnectGuardFlowStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3ConnectGuardFlowStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of Mac Sec Flow statistics.
These reflect the current data."
::= { f3ConnectGuardPerformanceObjects 1 }
f3ConnectGuardFlowStatsEntry OBJECT-TYPE
SYNTAX F3ConnectGuardFlowStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3ConnectGuardFlowStatsTable.
Entries exist in this table for each Connect Guard Flow."
INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardFlowStatsIndex }
::= { f3ConnectGuardFlowStatsTable 1 }
F3ConnectGuardFlowStatsEntry ::= SEQUENCE {
f3ConnectGuardFlowStatsIndex Integer32,
f3ConnectGuardFlowStatsIntervalType CmPmIntervalType,
f3ConnectGuardFlowStatsValid TruthValue,
f3ConnectGuardFlowStatsAction CmPmBinAction,
f3ConnectGuardFlowStatsTxUntaggedPkts PerfCounter64,
f3ConnectGuardFlowStatsTxTooLongPkts PerfCounter64,
f3ConnectGuardFlowStatsRxUntaggedPkts PerfCounter64,
f3ConnectGuardFlowStatsRxNotagPkts PerfCounter64,
f3ConnectGuardFlowStatsRxBadtagPkts PerfCounter64,
f3ConnectGuardFlowStatsRxUnknownSCIPkts PerfCounter64,
f3ConnectGuardFlowStatsRxNoSCIPkts PerfCounter64,
f3ConnectGuardFlowStatsRxOverrunPkts PerfCounter64
}
f3ConnectGuardFlowStatsIndex OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer index value used to uniquely identify
this Connect Guard Flow statistics entry.
1 - 15min
2 - 1day
3 - rollover
4 - 5min"
::= { f3ConnectGuardFlowStatsEntry 1 }
f3ConnectGuardFlowStatsIntervalType OBJECT-TYPE
SYNTAX CmPmIntervalType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the type of collection, i.e. whether it is
15 Min, 1 Day or rollover."
::= { f3ConnectGuardFlowStatsEntry 2 }
f3ConnectGuardFlowStatsValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the validity of the bin."
::= { f3ConnectGuardFlowStatsEntry 3 }
f3ConnectGuardFlowStatsAction OBJECT-TYPE
SYNTAX CmPmBinAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allows the operator to clear the bin."
::= { f3ConnectGuardFlowStatsEntry 4 }
f3ConnectGuardFlowStatsTxUntaggedPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted packets without the MAC security tag (SecTAG)."
::= { f3ConnectGuardFlowStatsEntry 5 }
f3ConnectGuardFlowStatsTxTooLongPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted packets discarded because the packet
length is greater than the ifMtu of the Common Port interface."
::= { f3ConnectGuardFlowStatsEntry 6 }
f3ConnectGuardFlowStatsRxUntaggedPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received packets without the MAC security tag(SecTAG)."
::= { f3ConnectGuardFlowStatsEntry 7 }
f3ConnectGuardFlowStatsRxNotagPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received packets discarded without the MAC security tag (SecTAG)."
::= { f3ConnectGuardFlowStatsEntry 8 }
f3ConnectGuardFlowStatsRxBadtagPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received packets discarded with an invalid
SecTAG or a zero value PN or an invalid ICV."
::= { f3ConnectGuardFlowStatsEntry 9 }
f3ConnectGuardFlowStatsRxUnknownSCIPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received packets with unknown SCI."
::= { f3ConnectGuardFlowStatsEntry 10 }
f3ConnectGuardFlowStatsRxNoSCIPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received packets discarded with unknown SCI information."
::= { f3ConnectGuardFlowStatsEntry 11 }
f3ConnectGuardFlowStatsRxOverrunPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets discarded because the number of
received packets exceeded the cryptographic performance
capabilities."
::= { f3ConnectGuardFlowStatsEntry 12 }
--
-- Mac Sec Flow History Statistics Table
--
f3ConnectGuardFlowHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3ConnectGuardFlowHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of Connect Guard Flow history statistics.
These reflect the history data."
::= { f3ConnectGuardPerformanceObjects 2 }
f3ConnectGuardFlowHistoryEntry OBJECT-TYPE
SYNTAX F3ConnectGuardFlowHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3ConnectGuardFlowHistoryTable.
Entries exist in this table for each Connect Guard Flow."
INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardFlowStatsIndex, f3ConnectGuardFlowHistoryIndex }
::= { f3ConnectGuardFlowHistoryTable 1 }
F3ConnectGuardFlowHistoryEntry ::= SEQUENCE {
f3ConnectGuardFlowHistoryIndex Integer32,
f3ConnectGuardFlowHistoryTime DateAndTime,
f3ConnectGuardFlowHistoryValid TruthValue,
f3ConnectGuardFlowHistoryAction CmPmBinAction,
f3ConnectGuardFlowHistoryTxUntaggedPkts PerfCounter64,
f3ConnectGuardFlowHistoryTxTooLongPkts PerfCounter64,
f3ConnectGuardFlowHistoryRxUntaggedPkts PerfCounter64,
f3ConnectGuardFlowHistoryRxNotagPkts PerfCounter64,
f3ConnectGuardFlowHistoryRxBadtagPkts PerfCounter64,
f3ConnectGuardFlowHistoryRxUnknownSCIPkts PerfCounter64,
f3ConnectGuardFlowHistoryRxNoSCIPkts PerfCounter64,
f3ConnectGuardFlowHistoryRxOverrunPkts PerfCounter64
}
f3ConnectGuardFlowHistoryIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer index value used to uniquely identify
this Connect Guard Flow statistics entry."
::= { f3ConnectGuardFlowHistoryEntry 1 }
f3ConnectGuardFlowHistoryTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the time of history bin creation."
::= { f3ConnectGuardFlowHistoryEntry 2 }
f3ConnectGuardFlowHistoryValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the validity of the bin."
::= { f3ConnectGuardFlowHistoryEntry 3 }
f3ConnectGuardFlowHistoryAction OBJECT-TYPE
SYNTAX CmPmBinAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allows the operator to clear the bin."
::= { f3ConnectGuardFlowHistoryEntry 4 }
f3ConnectGuardFlowHistoryTxUntaggedPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted packets without the MAC security tag (SecTAG)."
::= { f3ConnectGuardFlowHistoryEntry 5 }
f3ConnectGuardFlowHistoryTxTooLongPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted packets discarded because the packet
length is greater than the ifMtu of the Common Port interface."
::= { f3ConnectGuardFlowHistoryEntry 6 }
f3ConnectGuardFlowHistoryRxUntaggedPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received packets without the MAC security tag(SecTAG)."
::= { f3ConnectGuardFlowHistoryEntry 7 }
f3ConnectGuardFlowHistoryRxNotagPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received packets discarded without the MAC security tag (SecTAG)."
::= { f3ConnectGuardFlowHistoryEntry 8 }
f3ConnectGuardFlowHistoryRxBadtagPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received packets discarded with an invalid
SecTAG or a zero value PN or an invalid ICV."
::= { f3ConnectGuardFlowHistoryEntry 9 }
f3ConnectGuardFlowHistoryRxUnknownSCIPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received packets with unknown SCI."
::= { f3ConnectGuardFlowHistoryEntry 10 }
f3ConnectGuardFlowHistoryRxNoSCIPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received packets discarded with unknown SCI information."
::= { f3ConnectGuardFlowHistoryEntry 11 }
f3ConnectGuardFlowHistoryRxOverrunPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets discarded because the number of
received packets exceeded the cryptographic performance
capabilities."
::= { f3ConnectGuardFlowHistoryEntry 12 }
--
-- Connect Guard Flow Threshold Table
--
f3ConnectGuardFlowThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3ConnectGuardFlowThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of entries that allow manageability of Connect Guard Flow
Thresholds."
::= { f3ConnectGuardPerformanceObjects 3 }
f3ConnectGuardFlowThresholdEntry OBJECT-TYPE
SYNTAX F3ConnectGuardFlowThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3PtpAccPortFlowPointThresholdTable."
INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardFlowStatsIndex,
f3ConnectGuardFlowThresholdIndex }
::= { f3ConnectGuardFlowThresholdTable 1 }
F3ConnectGuardFlowThresholdEntry ::= SEQUENCE {
f3ConnectGuardFlowThresholdIndex Integer32,
f3ConnectGuardFlowThresholdInterval CmPmIntervalType,
f3ConnectGuardFlowThresholdVariable VariablePointer,
f3ConnectGuardFlowThresholdValueLo Unsigned32,
f3ConnectGuardFlowThresholdValueHi Unsigned32,
f3ConnectGuardFlowThresholdMonValue PerfCounter64
}
f3ConnectGuardFlowThresholdIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the
f3ConnectGuardFlowThresholdTable."
::= { f3ConnectGuardFlowThresholdEntry 1 }
f3ConnectGuardFlowThresholdInterval OBJECT-TYPE
SYNTAX CmPmIntervalType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interval over which monitored value is
sampled and compared with the specified threshold."
::= { f3ConnectGuardFlowThresholdEntry 2 }
f3ConnectGuardFlowThresholdVariable OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object identifier of the particular variable to be
sampled."
::= { f3ConnectGuardFlowThresholdEntry 3 }
f3ConnectGuardFlowThresholdValueLo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Lower 32 bits of the threshold value."
::= { f3ConnectGuardFlowThresholdEntry 4 }
f3ConnectGuardFlowThresholdValueHi OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Higher 32 bits of the threshold value."
::= { f3ConnectGuardFlowThresholdEntry 5 }
f3ConnectGuardFlowThresholdMonValue OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Monitored value corresponding to f3ConnectGuardFlowThresholdVariable."
::= { f3ConnectGuardFlowThresholdEntry 6 }
--
-- Connect Guard TX SC Current Statistics Table
--
f3ConnectGuardTxSCStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3ConnectGuardTxSCStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of Connect Guard TxSC statistics.
These reflect the current data."
::= { f3ConnectGuardPerformanceObjects 4 }
f3ConnectGuardTxSCStatsEntry OBJECT-TYPE
SYNTAX F3ConnectGuardTxSCStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3ConnectGuardTxSCStatsTable.
Entries exist in this table for each Connect Guard TxSC."
INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardTxSCIndex, f3ConnectGuardTxSCStatsIndex }
::= { f3ConnectGuardTxSCStatsTable 1 }
F3ConnectGuardTxSCStatsEntry ::= SEQUENCE {
f3ConnectGuardTxSCStatsIndex Integer32,
f3ConnectGuardTxSCStatsIntervalType CmPmIntervalType,
f3ConnectGuardTxSCStatsValid TruthValue,
f3ConnectGuardTxSCStatsAction CmPmBinAction,
f3ConnectGuardTxSCStatsTxProtectedPkts PerfCounter64,
f3ConnectGuardTxSCStatsTxEncryptedPkts PerfCounter64,
f3ConnectGuardTxSCStatsTxOctetsProtected PerfCounter64,
f3ConnectGuardTxSCStatsTxOctetsEncrypted PerfCounter64
}
f3ConnectGuardTxSCStatsIndex OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer index value used to uniquely identify
this Connect Guard TX SC statistics entry.
1 - 15min
2 - 1day
3 - rollover
4 - 5min"
::= { f3ConnectGuardTxSCStatsEntry 1 }
f3ConnectGuardTxSCStatsIntervalType OBJECT-TYPE
SYNTAX CmPmIntervalType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the type of collection, i.e. whether it is
15 Min, 1 Day or rollover."
::= { f3ConnectGuardTxSCStatsEntry 2 }
f3ConnectGuardTxSCStatsValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the validity of the bin."
::= { f3ConnectGuardTxSCStatsEntry 3 }
f3ConnectGuardTxSCStatsAction OBJECT-TYPE
SYNTAX CmPmBinAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allows the operator to clear the bin."
::= { f3ConnectGuardTxSCStatsEntry 4 }
f3ConnectGuardTxSCStatsTxProtectedPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of integrity protected but not encrypted packets."
::= { f3ConnectGuardTxSCStatsEntry 5 }
f3ConnectGuardTxSCStatsTxEncryptedPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of integrity protected and encrypted packets."
::= { f3ConnectGuardTxSCStatsEntry 6 }
f3ConnectGuardTxSCStatsTxOctetsProtected OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of plain text octets that are integrity protected
but not encrypted."
::= { f3ConnectGuardTxSCStatsEntry 7 }
f3ConnectGuardTxSCStatsTxOctetsEncrypted OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of plain text octets that are integrity protected
and encrypted."
::= { f3ConnectGuardTxSCStatsEntry 8 }
--
-- Connect Guard TX SC History Statistics Table
--
f3ConnectGuardTxSCHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3ConnectGuardTxSCHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of Connect Guard TxSC history statistics.
These reflect the history data."
::= { f3ConnectGuardPerformanceObjects 5 }
f3ConnectGuardTxSCHistoryEntry OBJECT-TYPE
SYNTAX F3ConnectGuardTxSCHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3ConnectGuardTxSCHistoryTable.
Entries exist in this table for each Connect Guard TX SC."
INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardTxSCIndex, f3ConnectGuardTxSCStatsIndex, f3ConnectGuardTxSCHistoryIndex }
::= { f3ConnectGuardTxSCHistoryTable 1 }
F3ConnectGuardTxSCHistoryEntry ::= SEQUENCE {
f3ConnectGuardTxSCHistoryIndex Integer32,
f3ConnectGuardTxSCHistoryTime DateAndTime,
f3ConnectGuardTxSCHistoryValid TruthValue,
f3ConnectGuardTxSCHistoryAction CmPmBinAction,
f3ConnectGuardTxSCHistoryTxProtectedPkts PerfCounter64,
f3ConnectGuardTxSCHistoryTxEncryptedPkts PerfCounter64,
f3ConnectGuardTxSCHistoryTxOctetsProtected PerfCounter64,
f3ConnectGuardTxSCHistoryTxOctetsEncrypted PerfCounter64
}
f3ConnectGuardTxSCHistoryIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer index value used to uniquely identify
this Connect Guard TxSC statistics entry."
::= { f3ConnectGuardTxSCHistoryEntry 1 }
f3ConnectGuardTxSCHistoryTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the time of history bin creation."
::= { f3ConnectGuardTxSCHistoryEntry 2 }
f3ConnectGuardTxSCHistoryValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the validity of the bin."
::= { f3ConnectGuardTxSCHistoryEntry 3 }
f3ConnectGuardTxSCHistoryAction OBJECT-TYPE
SYNTAX CmPmBinAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allows the operator to clear the bin."
::= { f3ConnectGuardTxSCHistoryEntry 4 }
f3ConnectGuardTxSCHistoryTxProtectedPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of integrity protected but not encrypted packets."
::= { f3ConnectGuardTxSCHistoryEntry 5 }
f3ConnectGuardTxSCHistoryTxEncryptedPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of integrity protected and encrypted packets."
::= { f3ConnectGuardTxSCHistoryEntry 6 }
f3ConnectGuardTxSCHistoryTxOctetsProtected OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of plain text octets that are integrity protected
but not encrypted."
::= { f3ConnectGuardTxSCHistoryEntry 7 }
f3ConnectGuardTxSCHistoryTxOctetsEncrypted OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of plain text octets that are integrity protected
and encrypted."
::= { f3ConnectGuardTxSCHistoryEntry 8 }
--
-- Connect Guard TX SC Threshold Table
--
f3ConnectGuardTxSCThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3ConnectGuardTxSCThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of entries that allow manageability of Connect Guard TxSC
Thresholds."
::= { f3ConnectGuardPerformanceObjects 6 }
f3ConnectGuardTxSCThresholdEntry OBJECT-TYPE
SYNTAX F3ConnectGuardTxSCThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3ConnectGuardTxSCThresholdEntry."
INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardTxSCIndex, f3ConnectGuardTxSCStatsIndex,
f3ConnectGuardTxSCThresholdIndex }
::= { f3ConnectGuardTxSCThresholdTable 1 }
F3ConnectGuardTxSCThresholdEntry ::= SEQUENCE {
f3ConnectGuardTxSCThresholdIndex Integer32,
f3ConnectGuardTxSCThresholdInterval CmPmIntervalType,
f3ConnectGuardTxSCThresholdVariable VariablePointer,
f3ConnectGuardTxSCThresholdValueLo Unsigned32,
f3ConnectGuardTxSCThresholdValueHi Unsigned32,
f3ConnectGuardTxSCThresholdMonValue PerfCounter64
}
f3ConnectGuardTxSCThresholdIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the
f3ConnectGuardTxSCThresholdTable."
::= { f3ConnectGuardTxSCThresholdEntry 1 }
f3ConnectGuardTxSCThresholdInterval OBJECT-TYPE
SYNTAX CmPmIntervalType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interval over which monitored value is
sampled and compared with the specified threshold."
::= { f3ConnectGuardTxSCThresholdEntry 2 }
f3ConnectGuardTxSCThresholdVariable OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object identifier of the particular variable to be
sampled."
::= { f3ConnectGuardTxSCThresholdEntry 3 }
f3ConnectGuardTxSCThresholdValueLo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Lower 32 bits of the threshold value."
::= { f3ConnectGuardTxSCThresholdEntry 4 }
f3ConnectGuardTxSCThresholdValueHi OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Higher 32 bits of the threshold value."
::= { f3ConnectGuardTxSCThresholdEntry 5 }
f3ConnectGuardTxSCThresholdMonValue OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Monitored value corresponding to f3ConnectGuardTxSCThresholdVariable."
::= { f3ConnectGuardTxSCThresholdEntry 6 }
--
-- Connect Guard RX SC Current Statistics Table
--
f3ConnectGuardRxSCStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3ConnectGuardRxSCStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of Connect Guard RxSC statistics.
These reflect the current data."
::= { f3ConnectGuardPerformanceObjects 7 }
f3ConnectGuardRxSCStatsEntry OBJECT-TYPE
SYNTAX F3ConnectGuardRxSCStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3ConnectGuardRxSCStatsTable.
Entries exist in this table for each Connect Guard RxSC."
INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardRxSCIndex, f3ConnectGuardRxSCStatsIndex }
::= { f3ConnectGuardRxSCStatsTable 1 }
F3ConnectGuardRxSCStatsEntry ::= SEQUENCE {
f3ConnectGuardRxSCStatsIndex Integer32,
f3ConnectGuardRxSCStatsIntervalType CmPmIntervalType,
f3ConnectGuardRxSCStatsValid TruthValue,
f3ConnectGuardRxSCStatsAction CmPmBinAction,
f3ConnectGuardRxSCStatsRxUnusedSAPkts PerfCounter64,
f3ConnectGuardRxSCStatsRxNoUsingSAPkts PerfCounter64,
f3ConnectGuardRxSCStatsRxLatePkts PerfCounter64,
f3ConnectGuardRxSCStatsRxNotValidPkts PerfCounter64,
f3ConnectGuardRxSCStatsRxInvalidPkts PerfCounter64,
f3ConnectGuardRxSCStatsRxDelayedPkts PerfCounter64,
f3ConnectGuardRxSCStatsRxUncheckedPkts PerfCounter64,
f3ConnectGuardRxSCStatsRxOKPkts PerfCounter64,
f3ConnectGuardRxSCStatsRxOctetsValidated PerfCounter64,
f3ConnectGuardRxSCStatsRxOctetsDecrypted PerfCounter64
}
f3ConnectGuardRxSCStatsIndex OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer index value used to uniquely identify
this Connect Guard Rx SC statistics entry.
1 - 15min
2 - 1day
3 - rollover
4 - 5min"
::= { f3ConnectGuardRxSCStatsEntry 1 }
f3ConnectGuardRxSCStatsIntervalType OBJECT-TYPE
SYNTAX CmPmIntervalType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the type of collection, i.e. whether it is
15 Min, 1 Day or rollover."
::= { f3ConnectGuardRxSCStatsEntry 2 }
f3ConnectGuardRxSCStatsValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the validity of the bin."
::= { f3ConnectGuardRxSCStatsEntry 3 }
f3ConnectGuardRxSCStatsAction OBJECT-TYPE
SYNTAX CmPmBinAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allows the operator to clear the bin."
::= { f3ConnectGuardRxSCStatsEntry 4 }
f3ConnectGuardRxSCStatsRxUnusedSAPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The summation of counter secyRxSAStatsUnusedSAPkts
information for all the SAs."
::= { f3ConnectGuardRxSCStatsEntry 5 }
f3ConnectGuardRxSCStatsRxNoUsingSAPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The summation of counter secyRxSAStatsNoUsingSAPkts
information for all the SAs."
::= { f3ConnectGuardRxSCStatsEntry 6 }
f3ConnectGuardRxSCStatsRxLatePkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"the number of received packets that have
been discarded with the condition : secyReplayProtect is equal
to true and the PN of the packet is lower than the lower bound
replay check PN."
::= { f3ConnectGuardRxSCStatsEntry 7 }
f3ConnectGuardRxSCStatsRxNotValidPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The summation of counter secyRxSAStatsNotValidPkts
information for all the SAs."
::= { f3ConnectGuardRxSCStatsEntry 8 }
f3ConnectGuardRxSCStatsRxInvalidPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The summation of counter secyRxSAStatsInvalidPkts
information for all the SAs."
::= { f3ConnectGuardRxSCStatsEntry 9 }
f3ConnectGuardRxSCStatsRxDelayedPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets with the condition
that the PN of the packets is lower than the lower bound
replay protection PN."
::= { f3ConnectGuardRxSCStatsEntry 10 }
f3ConnectGuardRxSCStatsRxUncheckedPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets with the following condition:
-secyValidateFrames is disabled or
-secyValidateFrames is not disabled and the packet is not
encrypted and the integrity check has failed or
-secyValidateFrames is not disable and the packet is
encrypted and integrity check has failed."
::= { f3ConnectGuardRxSCStatsEntry 11 }
f3ConnectGuardRxSCStatsRxOKPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The summation of counter secyRxSAStatsOKPkts
information for all the SAs."
::= { f3ConnectGuardRxSCStatsEntry 12 }
f3ConnectGuardRxSCStatsRxOctetsValidated OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets of plaintext recovered from received
packets that were integrity protected but not encrypted."
::= { f3ConnectGuardRxSCStatsEntry 13 }
f3ConnectGuardRxSCStatsRxOctetsDecrypted OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets of plaintext recovered from received
packets that were integrity protected and encrypted."
::= { f3ConnectGuardRxSCStatsEntry 14 }
--
-- Connect Guard RX SC History Statistics Table
--
f3ConnectGuardRxSCHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3ConnectGuardRxSCHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of Connect Guard RxSC history statistics.
These reflect the history data."
::= { f3ConnectGuardPerformanceObjects 8 }
f3ConnectGuardRxSCHistoryEntry OBJECT-TYPE
SYNTAX F3ConnectGuardRxSCHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3ConnectGuardRxSCHistoryTable.
Entries exist in this table for each Connect Guard Flow RX SC."
INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardRxSCIndex, f3ConnectGuardRxSCStatsIndex, f3ConnectGuardRxSCHistoryIndex }
::= { f3ConnectGuardRxSCHistoryTable 1 }
F3ConnectGuardRxSCHistoryEntry ::= SEQUENCE {
f3ConnectGuardRxSCHistoryIndex Integer32,
f3ConnectGuardRxSCHistoryTime DateAndTime,
f3ConnectGuardRxSCHistoryValid TruthValue,
f3ConnectGuardRxSCHistoryAction CmPmBinAction,
f3ConnectGuardRxSCHistoryRxUnusedSAPkts PerfCounter64,
f3ConnectGuardRxSCHistoryRxNoUsingSAPkts PerfCounter64,
f3ConnectGuardRxSCHistoryRxLatePkts PerfCounter64,
f3ConnectGuardRxSCHistoryRxNotValidPkts PerfCounter64,
f3ConnectGuardRxSCHistoryRxInvalidPkts PerfCounter64,
f3ConnectGuardRxSCHistoryRxDelayedPkts PerfCounter64,
f3ConnectGuardRxSCHistoryRxUncheckedPkts PerfCounter64,
f3ConnectGuardRxSCHistoryRxOKPkts PerfCounter64,
f3ConnectGuardRxSCHistoryRxOctetsValidated PerfCounter64,
f3ConnectGuardRxSCHistoryRxOctetsDecrypted PerfCounter64
}
f3ConnectGuardRxSCHistoryIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer index value used to uniquely identify
this Connect Guard RxSC statistics entry."
::= { f3ConnectGuardRxSCHistoryEntry 1 }
f3ConnectGuardRxSCHistoryTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the time of history bin creation."
::= { f3ConnectGuardRxSCHistoryEntry 2 }
f3ConnectGuardRxSCHistoryValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the validity of the bin."
::= { f3ConnectGuardRxSCHistoryEntry 3 }
f3ConnectGuardRxSCHistoryAction OBJECT-TYPE
SYNTAX CmPmBinAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allows the operator to clear the bin."
::= { f3ConnectGuardRxSCHistoryEntry 4 }
f3ConnectGuardRxSCHistoryRxUnusedSAPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The summation of counter secyRxSAStatsUnusedSAPkts
information for all the SAs."
::= { f3ConnectGuardRxSCHistoryEntry 5 }
f3ConnectGuardRxSCHistoryRxNoUsingSAPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The summation of counter secyRxSAStatsNoUsingSAPkts
information for all the SAs."
::= { f3ConnectGuardRxSCHistoryEntry 6 }
f3ConnectGuardRxSCHistoryRxLatePkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"the number of received packets that have
been discarded with the condition : secyReplayProtect is equal
to true and the PN of the packet is lower than the lower bound
replay check PN."
::= { f3ConnectGuardRxSCHistoryEntry 7 }
f3ConnectGuardRxSCHistoryRxNotValidPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The summation of counter secyRxSAStatsNotValidPkts
information for all the SAs."
::= { f3ConnectGuardRxSCHistoryEntry 8 }
f3ConnectGuardRxSCHistoryRxInvalidPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The summation of counter secyRxSAStatsInvalidPkts
information for all the SAs."
::= { f3ConnectGuardRxSCHistoryEntry 9 }
f3ConnectGuardRxSCHistoryRxDelayedPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets with the condition
that the PN of the packets is lower than the lower bound
replay protection PN."
::= { f3ConnectGuardRxSCHistoryEntry 10 }
f3ConnectGuardRxSCHistoryRxUncheckedPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets with the following condition:
-secyValidateFrames is disabled or
-secyValidateFrames is not disabled and the packet is not
encrypted and the integrity check has failed or
-secyValidateFrames is not disable and the packet is
encrypted and integrity check has failed."
::= { f3ConnectGuardRxSCHistoryEntry 11 }
f3ConnectGuardRxSCHistoryRxOKPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The summation of counter secyRxSAStatsOKPkts
information for all the SAs."
::= { f3ConnectGuardRxSCHistoryEntry 12 }
f3ConnectGuardRxSCHistoryRxOctetsValidated OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets of plaintext recovered from received
packets that were integrity protected but not encrypted."
::= { f3ConnectGuardRxSCHistoryEntry 13 }
f3ConnectGuardRxSCHistoryRxOctetsDecrypted OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets of plaintext recovered from received
packets that were integrity protected and encrypted."
::= { f3ConnectGuardRxSCHistoryEntry 14 }
--
-- Connect Guard RX SC Threshold Table
--
f3ConnectGuardRxSCThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3ConnectGuardRxSCThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of entries that allow manageability of Connect Guard RxSC
Thresholds."
::= { f3ConnectGuardPerformanceObjects 9 }
f3ConnectGuardRxSCThresholdEntry OBJECT-TYPE
SYNTAX F3ConnectGuardRxSCThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3ConnectGuardRxSCThresholdEntry."
INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardRxSCIndex, f3ConnectGuardRxSCStatsIndex,
f3ConnectGuardRxSCThresholdIndex }
::= { f3ConnectGuardRxSCThresholdTable 1 }
F3ConnectGuardRxSCThresholdEntry ::= SEQUENCE {
f3ConnectGuardRxSCThresholdIndex Integer32,
f3ConnectGuardRxSCThresholdInterval CmPmIntervalType,
f3ConnectGuardRxSCThresholdVariable VariablePointer,
f3ConnectGuardRxSCThresholdValueLo Unsigned32,
f3ConnectGuardRxSCThresholdValueHi Unsigned32,
f3ConnectGuardRxSCThresholdMonValue PerfCounter64
}
f3ConnectGuardRxSCThresholdIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the
f3ConnectGuardRxSCThresholdTable."
::= { f3ConnectGuardRxSCThresholdEntry 1 }
f3ConnectGuardRxSCThresholdInterval OBJECT-TYPE
SYNTAX CmPmIntervalType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interval over which monitored value is
sampled and compared with the specified threshold."
::= { f3ConnectGuardRxSCThresholdEntry 2 }
f3ConnectGuardRxSCThresholdVariable OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object identifier of the particular variable to be
sampled."
::= { f3ConnectGuardRxSCThresholdEntry 3 }
f3ConnectGuardRxSCThresholdValueLo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Lower 32 bits of the threshold value."
::= { f3ConnectGuardRxSCThresholdEntry 4 }
f3ConnectGuardRxSCThresholdValueHi OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Higher 32 bits of the threshold value."
::= { f3ConnectGuardRxSCThresholdEntry 5 }
f3ConnectGuardRxSCThresholdMonValue OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Monitored value corresponding to f3ConnectGuardRxSCThresholdVariable."
::= { f3ConnectGuardRxSCThresholdEntry 6 }
--
-- Connect Guard Tx SA Statistics Table
--
f3ConnectGuardTxSAStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3ConnectGuardTxSAStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of Connect Guard Tx SA statistics.
These reflect the current data."
::= { f3ConnectGuardPerformanceObjects 10 }
f3ConnectGuardTxSAStatsEntry OBJECT-TYPE
SYNTAX F3ConnectGuardTxSAStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3ConnectGuardTxSAStatsTable.
Entries exist in this table for each Connect Guard TxSA."
INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardTxSCIndex,f3ConnectGuardTxSAIndex }
::= { f3ConnectGuardTxSAStatsTable 1 }
F3ConnectGuardTxSAStatsEntry ::= SEQUENCE {
f3ConnectGuardTxSAStatsProtectedPkts PerfCounter64,
f3ConnectGuardTxSAStatsEncryptedPkts PerfCounter64
}
f3ConnectGuardTxSAStatsProtectedPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of integrity protected but not encrypted packets
for this transmitting SA."
::= { f3ConnectGuardTxSAStatsEntry 1 }
f3ConnectGuardTxSAStatsEncryptedPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of integrity protected and encrypted packets for
this transmitting SA."
::= { f3ConnectGuardTxSAStatsEntry 2 }
--
-- Connect Guard Rx SA Statistics Table
--
f3ConnectGuardRxSAStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3ConnectGuardRxSAStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of Connect Guard Rx SA statistics.
These reflect the current data."
::= { f3ConnectGuardPerformanceObjects 11 }
f3ConnectGuardRxSAStatsEntry OBJECT-TYPE
SYNTAX F3ConnectGuardRxSAStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3ConnectGuardRxSAStatsTable.
Entries exist in this table for each Connect Guard RxSA."
INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardRxSCIndex ,f3ConnectGuardRxSAIndex }
::= { f3ConnectGuardRxSAStatsTable 1 }
F3ConnectGuardRxSAStatsEntry ::= SEQUENCE {
f3ConnectGuardRxSAStatsUnusedSAPkts PerfCounter64,
f3ConnectGuardRxSAStatsNoUsingSAPkts PerfCounter64,
f3ConnectGuardRxSAStatsNotValidPkts PerfCounter64,
f3ConnectGuardRxSAStatsInvalidPkts PerfCounter64,
f3ConnectGuardRxSAStatsOKPkts PerfCounter64
}
f3ConnectGuardRxSAStatsUnusedSAPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For this SA which is not currently in use, the number of
received, unencrypted, packets with secyValidateFrames
not in the strict mode."
::= { f3ConnectGuardRxSAStatsEntry 1 }
f3ConnectGuardRxSAStatsNoUsingSAPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For this SA which is not currently in use, the number of
received packets that have been discarded, and have
either the packets encrypted or the secyValidateFrames set to
strict mode."
::= { f3ConnectGuardRxSAStatsEntry 2 }
f3ConnectGuardRxSAStatsNotValidPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For this SA, the number discarded packets with the
condition that the packets are not valid and one of the
following conditions are true: either secyValidateFrames in
strict mode or the packets encrypted."
::= { f3ConnectGuardRxSAStatsEntry 3 }
f3ConnectGuardRxSAStatsInvalidPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For this SA, the number of packets with the condition
that the packets are not valid and secyValidateFrames is in
check mode."
::= { f3ConnectGuardRxSAStatsEntry 4 }
f3ConnectGuardRxSAStatsOKPkts OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For this SA, the number of validated packets."
::= { f3ConnectGuardRxSAStatsEntry 5 }
---
---Notifications
---
f3ConnectGuardFlowThresholdCrossingAlert NOTIFICATION-TYPE
OBJECTS {
f3ConnectGuardFlowThresholdIndex,
f3ConnectGuardFlowThresholdInterval,
f3ConnectGuardFlowThresholdVariable,
f3ConnectGuardFlowThresholdValueLo,
f3ConnectGuardFlowThresholdValueHi,
f3ConnectGuardFlowThresholdMonValue
}
STATUS current
DESCRIPTION
"This trap is sent each time a threshold on a PM condition
on an Connect Guard flow is crossed."
::= { f3ConnectGuardNotifications 1 }
f3ConnectGuardTxSCThresholdCrossingAlert NOTIFICATION-TYPE
OBJECTS {
f3ConnectGuardTxSCThresholdIndex,
f3ConnectGuardTxSCThresholdInterval,
f3ConnectGuardTxSCThresholdVariable,
f3ConnectGuardTxSCThresholdValueLo,
f3ConnectGuardTxSCThresholdValueHi,
f3ConnectGuardTxSCThresholdMonValue
}
STATUS current
DESCRIPTION
"This trap is sent each time a threshold on a PM condition
on an Connect Guard Tx SC is crossed."
::= { f3ConnectGuardNotifications 2 }
f3ConnectGuardRxSCThresholdCrossingAlert NOTIFICATION-TYPE
OBJECTS {
f3ConnectGuardRxSCThresholdIndex,
f3ConnectGuardRxSCThresholdInterval,
f3ConnectGuardRxSCThresholdVariable,
f3ConnectGuardRxSCThresholdValueLo,
f3ConnectGuardRxSCThresholdValueHi,
f3ConnectGuardRxSCThresholdMonValue
}
STATUS current
DESCRIPTION
"This trap is sent each time a threshold on a PM condition
on an Connect Guard Rx SC is crossed."
::= { f3ConnectGuardNotifications 3 }
f3ConnectGuardStateChangeTrap NOTIFICATION-TYPE
OBJECTS {
f3FlowSecureState
}
STATUS current
DESCRIPTION
"This trap is sent each time secure state value changed."
::= { f3ConnectGuardNotifications 4 }
--
-- Conformance
--
f3ConnectGuardCompliances OBJECT IDENTIFIER ::= {f3ConnectGuardConformance 1}
f3ConnectGuardGroups OBJECT IDENTIFIER ::= {f3ConnectGuardConformance 2}
f3ConnectGuardCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to the Connect Guard."
MODULE -- this module
MANDATORY-GROUPS {
f3ConnectGuardObjectsGroup, f3ConnectGuardPerfGroup
}
::= { f3ConnectGuardCompliances 1 }
f3ConnectGuardObjectsGroup OBJECT-GROUP
OBJECTS {
f3ConnectGuardFlowIndex,f3ConnectGuardFlowEgressInterface,
f3ConnectGuardFlowAdminState,f3ConnectGuardFlowSecondaryState,
f3ConnectGuardFlowOperationalState,f3ConnectGuardFlowCipherSuite,
f3ConnectGuardFlowKeyExchangeProfile,f3ConnectGuardFlowKeyExchangeFrameTagControl,
f3ConnectGuardFlowKeyExchangeFrameOuterVlanEnabled,
f3ConnectGuardFlowKeyExchangeFrameOuterVlanId,
f3ConnectGuardFlowKeyExchangeFrameOuterVlanPriority,
f3ConnectGuardFlowKeyExchangeFrameInner1VlanEnabled,
f3ConnectGuardFlowKeyExchangeFrameInner1VlanId,
f3ConnectGuardFlowKeyExchangeFrameInner1VlanPriority,
f3ConnectGuardFlowKeyExchangeFrameInner2VlanEnabled,
f3ConnectGuardFlowKeyExchangeFrameInner2VlanId,
f3ConnectGuardFlowKeyExchangeFrameInner2VlanPriority,
f3ConnectGuardFlowKeyExchangeInterval,f3ConnectGuardFlowTagsClear,
f3ConnectGuardFlowStorageType,f3ConnectGuardFlowRowStatus,
f3ConnectGuardFlowKeyXchgFailsCounts,f3ConnectGuardFlowAction,
f3ConnectGuardFlowReplayProtectionEnabled,
f3ConnectGuardFlowReplayProtectionWindow,f3ConnectGuardFlowRemoteMacAddrEnabled,
f3ConnectGuardFlowRemoteMacAddr, f3ConnectGuardFlowAssociatedMep,
f3ConnectGuardFlowAlias,
f3ConnectGuardFlowKeyExchangeFrameOuterVlanEtherType,
f3ConnectGuardFlowKeyExchangeFrameInner1VlanEtherType,
f3ConnectGuardFlowKeyExchangeFrameInner2VlanEtherType,
f3ConnectGuardFlowKeyInjectFlowPoint,
f3ConnectGuardKeyExchangeProfileIndex,
f3ConnectGuardKeyExchangeProfileName,
f3ConnectGuardKeyExchangeProfileUserId,
f3ConnectGuardKeyExchangeProfileMode,
f3ConnectGuardKeyExchangeProfileAuthPassword,
f3ConnectGuardKeyExchangeProfileDiffieHellmanKeyPairLen,
f3ConnectGuardKeyExchangeProfileStorageType,
f3ConnectGuardKeyExchangeProfileRowStatus,
f3ConnectGuardTxSCIndex,
f3ConnectGuardTxSCI,
f3ConnectGuardTxScState,
f3ConnectGuardCurrentTxSa,
f3ConnectGuardPreviousTxSa,
f3ConnectGuardTxScCreateTime,
f3ConnectGuardTxScStartTime,
f3ConnectGuardTxScStopTime,
f3ConnectGuardRxSCIndex,
f3ConnectGuardRxSCI,
f3ConnectGuardRxScState,
f3ConnectGuardCurrentRxSa,
f3ConnectGuardRxScCreateTime,
f3ConnectGuardRxScStartTime,
f3ConnectGuardRxScStopTime,
f3ConnectGuardTxSAIndex,
f3ConnectGuardTxSAState,
f3ConnectGuardTxSANextPN,
f3ConnectGuardTxSASAKUnchanged,
f3ConnectGuardTxSACreatedTime,
f3ConnectGuardTxSAStartedTime,
f3ConnectGuardTxSAStoppedTime,
f3ConnectGuardRxSAIndex,
f3ConnectGuardRxSAState,
f3ConnectGuardRxSANextPN,
f3ConnectGuardRxSASAKUnchanged,
f3ConnectGuardRxSACreatedTime,
f3ConnectGuardRxSAStartedTime,
f3ConnectGuardRxSAStoppedTime,
f3ConnectGuardCryptoPassword, f3ConnectGuardRestoreFactoryApproved,f3ConnectGuardSoftwareVersionApproved,
f3ConnectGuardSoftwareInstallApproved,f3ConnectGuardRestoreDatabaseApproved,f3ConnectGuardConfigFileLoadApproved
}
STATUS current
DESCRIPTION
"A collection of objects used to manage the Connect Guard functionality."
::= { f3ConnectGuardGroups 1 }
f3ConnectGuardPerfGroup OBJECT-GROUP
OBJECTS {
f3ConnectGuardFlowStatsIndex,f3ConnectGuardFlowStatsIntervalType,
f3ConnectGuardFlowStatsValid,f3ConnectGuardFlowStatsAction,
f3ConnectGuardFlowStatsTxUntaggedPkts,f3ConnectGuardFlowStatsTxTooLongPkts,
f3ConnectGuardFlowStatsRxUntaggedPkts,f3ConnectGuardFlowStatsRxNotagPkts,
f3ConnectGuardFlowStatsRxBadtagPkts,f3ConnectGuardFlowStatsRxUnknownSCIPkts,
f3ConnectGuardFlowStatsRxNoSCIPkts,f3ConnectGuardFlowStatsRxOverrunPkts,
f3ConnectGuardFlowHistoryIndex,f3ConnectGuardFlowHistoryTime,
f3ConnectGuardFlowHistoryValid,f3ConnectGuardFlowHistoryAction,
f3ConnectGuardFlowHistoryTxUntaggedPkts,f3ConnectGuardFlowHistoryTxTooLongPkts,
f3ConnectGuardFlowHistoryRxUntaggedPkts,f3ConnectGuardFlowHistoryRxNotagPkts,
f3ConnectGuardFlowHistoryRxBadtagPkts,f3ConnectGuardFlowHistoryRxUnknownSCIPkts,
f3ConnectGuardFlowHistoryRxNoSCIPkts,f3ConnectGuardFlowHistoryRxOverrunPkts,
f3ConnectGuardFlowThresholdIndex,f3ConnectGuardFlowThresholdInterval,
f3ConnectGuardFlowThresholdVariable,f3ConnectGuardFlowThresholdValueLo,
f3ConnectGuardFlowThresholdValueHi,f3ConnectGuardFlowThresholdMonValue,
f3ConnectGuardTxSCStatsIndex,f3ConnectGuardTxSCStatsIntervalType,
f3ConnectGuardTxSCStatsValid,f3ConnectGuardTxSCStatsAction,
f3ConnectGuardTxSCStatsTxProtectedPkts,f3ConnectGuardTxSCStatsTxEncryptedPkts,
f3ConnectGuardTxSCStatsTxOctetsProtected,f3ConnectGuardTxSCStatsTxOctetsEncrypted,
f3ConnectGuardTxSCHistoryIndex,f3ConnectGuardTxSCHistoryTime,
f3ConnectGuardTxSCHistoryValid,f3ConnectGuardTxSCHistoryAction,
f3ConnectGuardTxSCHistoryTxProtectedPkts,f3ConnectGuardTxSCHistoryTxEncryptedPkts,
f3ConnectGuardTxSCHistoryTxOctetsProtected,f3ConnectGuardTxSCHistoryTxOctetsEncrypted,
f3ConnectGuardTxSCThresholdIndex,f3ConnectGuardTxSCThresholdInterval,
f3ConnectGuardTxSCThresholdVariable,f3ConnectGuardTxSCThresholdValueLo,
f3ConnectGuardTxSCThresholdValueHi,f3ConnectGuardTxSCThresholdMonValue,
f3ConnectGuardRxSCStatsIndex,f3ConnectGuardRxSCStatsIntervalType,
f3ConnectGuardRxSCStatsValid,f3ConnectGuardRxSCStatsAction,
f3ConnectGuardRxSCStatsRxUnusedSAPkts,f3ConnectGuardRxSCStatsRxNoUsingSAPkts,
f3ConnectGuardRxSCStatsRxLatePkts,f3ConnectGuardRxSCStatsRxNotValidPkts,
f3ConnectGuardRxSCStatsRxInvalidPkts,f3ConnectGuardRxSCStatsRxDelayedPkts,
f3ConnectGuardRxSCStatsRxUncheckedPkts,f3ConnectGuardRxSCStatsRxOKPkts,
f3ConnectGuardRxSCStatsRxOctetsValidated,f3ConnectGuardRxSCStatsRxOctetsDecrypted,
f3ConnectGuardRxSCHistoryIndex,f3ConnectGuardRxSCHistoryTime,
f3ConnectGuardRxSCHistoryValid,f3ConnectGuardRxSCHistoryAction,
f3ConnectGuardRxSCHistoryRxUnusedSAPkts,f3ConnectGuardRxSCHistoryRxNoUsingSAPkts,
f3ConnectGuardRxSCHistoryRxLatePkts,f3ConnectGuardRxSCHistoryRxNotValidPkts,
f3ConnectGuardRxSCHistoryRxInvalidPkts,f3ConnectGuardRxSCHistoryRxDelayedPkts,
f3ConnectGuardRxSCHistoryRxUncheckedPkts,f3ConnectGuardRxSCHistoryRxOKPkts,
f3ConnectGuardRxSCHistoryRxOctetsValidated,f3ConnectGuardRxSCHistoryRxOctetsDecrypted,
f3ConnectGuardRxSCThresholdIndex,f3ConnectGuardRxSCThresholdInterval,
f3ConnectGuardRxSCThresholdVariable,f3ConnectGuardRxSCThresholdValueLo,
f3ConnectGuardRxSCThresholdValueHi,f3ConnectGuardRxSCThresholdMonValue,
f3ConnectGuardTxSAStatsProtectedPkts,f3ConnectGuardTxSAStatsEncryptedPkts,
f3ConnectGuardRxSAStatsUnusedSAPkts,f3ConnectGuardRxSAStatsNoUsingSAPkts,
f3ConnectGuardRxSAStatsNotValidPkts,f3ConnectGuardRxSAStatsInvalidPkts,
f3ConnectGuardRxSAStatsOKPkts
}
STATUS current
DESCRIPTION
"A collection of objects performance used to manage the Connect Guard functionality."
::= { f3ConnectGuardGroups 2 }
END