F3-CONNECTGUARD-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
IMPORTS
 | 
						|
    MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, IpAddress
 | 
						|
             FROM SNMPv2-SMI
 | 
						|
    MODULE-COMPLIANCE, OBJECT-GROUP
 | 
						|
             FROM SNMPv2-CONF
 | 
						|
    DateAndTime, DisplayString, TruthValue, RowStatus, StorageType, 
 | 
						|
    MacAddress, VariablePointer, TEXTUAL-CONVENTION, TimeStamp
 | 
						|
             FROM SNMPv2-TC
 | 
						|
    Ipv6Address
 | 
						|
             FROM IPV6-TC
 | 
						|
    InterfaceIndex, ifIndex
 | 
						|
             FROM IF-MIB
 | 
						|
    SecySCI
 | 
						|
             FROM IEEE8021-SECY-MIB
 | 
						|
    PhysicalIndex
 | 
						|
             FROM ENTITY-MIB
 | 
						|
    neIndex, shelfIndex, slotIndex, f3UsbHostIndex, networkElementEntry
 | 
						|
             FROM CM-ENTITY-MIB
 | 
						|
    cmFlowEntry
 | 
						|
             FROM CM-FACILITY-MIB
 | 
						|
    f3AccFlowPointEntry
 | 
						|
             FROM F3-FPM-MIB
 | 
						|
    f3NetFlowPointEntry
 | 
						|
             FROM F3-FPM-MIB
 | 
						|
 | 
						|
    fsp150cm
 | 
						|
             FROM  ADVA-MIB 
 | 
						|
    AdminState, OperationalState, SecondaryState, EthernetMediaType, 
 | 
						|
    EthernetPortSpeed, TrafficDirection, SfpConnectorValue, SfpMediaType,
 | 
						|
    VlanId, VlanPriority, VlanTagType, PriorityMapMode, PerfCounter64,
 | 
						|
    AfpTagControl, VlanEthertype,CmPmIntervalType, CmPmBinAction,
 | 
						|
    F3DisplayString
 | 
						|
             FROM CM-COMMON-MIB;
 | 
						|
 | 
						|
f3ConnectGuardMIB MODULE-IDENTITY
 | 
						|
    LAST-UPDATED    "201607110000Z"
 | 
						|
    ORGANIZATION    "ADVA Optical Networking"
 | 
						|
    CONTACT-INFO
 | 
						|
            "        Jack Chen
 | 
						|
                     ADVA Optical Networking, Inc.
 | 
						|
                Tel: +86755 86217400-8205
 | 
						|
             E-mail: jchen@advaoptical.com
 | 
						|
             Postal: 
 | 
						|
             "
 | 
						|
    DESCRIPTION
 | 
						|
            "This module defines the Connect Guard MIB definitions used by 
 | 
						|
             the F3 (FSP150CM/CC) product lines.
 | 
						|
             Copyright (C) ADVA Optical Networking."
 | 
						|
    REVISION        "201607110000Z"
 | 
						|
    DESCRIPTION
 | 
						|
        "Notes from release 201607110000Z
 | 
						|
          a) added  FlowSecureState back to the mib since the mib has been released
 | 
						|
         Notes from release 201607080000Z
 | 
						|
          a) deprecated f3FlowExtConnectGuardTable moved the attributes to cmFlowTable
 | 
						|
          b) removed f3AccFlowpointExtConnectGuardTable and f3NetFlowpointExtConnectGuardTable
 | 
						|
             and moved the attributes to acc/net flowpoint tables
 | 
						|
         Notes from release 201606200000Z
 | 
						|
          a) added f3ConnectGuardFlowKeyInjectFlowPoint to f3ConnectGuardFlowTable
 | 
						|
         Notes from release 201606170000Z
 | 
						|
          a) added f3MPFlowExtConnectGuardTable
 | 
						|
         Notes from release 201606060000Z
 | 
						|
          a) added f3ConnectGuardFlowKeyExchangeFrameOuterVlanEtherType, f3ConnectGuardFlowKeyExchangeFrameInner1VlanEtherType,
 | 
						|
             and f3ConnectGuardFlowKeyExchangeFrameInner2VlanEtherType to f3ConnectGuardFlowTable
 | 
						|
         Notes from release 201605100000Z
 | 
						|
          a) added f3AccFlowpointExtConnectGuardTable and f3NetFlowpointExtConnectGuardTable
 | 
						|
             to support secure flow on flow point
 | 
						|
         Notes from release 201604120000Z
 | 
						|
          a) added system level scalar f3ConnectGuardCryptoPasswordControl
 | 
						|
         Notes from release 201601260000Z
 | 
						|
          a) add f3ConnectGuardFlowAlias to f3ConnectGuardFlowTable
 | 
						|
         Notes from release 201409120000Z
 | 
						|
          
 | 
						|
         Notes from release 201601040000Z
 | 
						|
           a) add f3ConnectGuardFlowAssociatedMep to f3ConnectGuardFlowTable
 | 
						|
        " 
 | 
						|
    ::= {fsp150cm 36}    
 | 
						|
 | 
						|
-- 
 | 
						|
-- OID definitions
 | 
						|
-- 
 | 
						|
f3ConnectGuardConfigObjects       OBJECT IDENTIFIER ::= {f3ConnectGuardMIB 1}
 | 
						|
f3ConnectGuardPerformanceObjects  OBJECT IDENTIFIER ::= {f3ConnectGuardMIB 2}
 | 
						|
f3ConnectGuardNotifications       OBJECT IDENTIFIER ::= {f3ConnectGuardMIB 3}
 | 
						|
f3ConnectGuardConformance         OBJECT IDENTIFIER ::= {f3ConnectGuardMIB 4}
 | 
						|
 | 
						|
 | 
						|
FlowSecureState ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION
 | 
						|
        "Flow secure state."
 | 
						|
    SYNTAX       INTEGER {
 | 
						|
                   secureNormal (1),
 | 
						|
                   secureBlocked (2),
 | 
						|
                   unsecureNormal (3),
 | 
						|
                   unsecureBlocked (4)
 | 
						|
                 }
 | 
						|
 | 
						|
CipherSuiteType ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
       "This object describes the cipher suite type."
 | 
						|
    SYNTAX INTEGER {
 | 
						|
                gcmAes256(1),
 | 
						|
                gcmAes128(2)
 | 
						|
               }
 | 
						|
 | 
						|
KeyExchangeFrameTagControl ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
       "This object describes the key exchange frame tag mode."
 | 
						|
    SYNTAX INTEGER {
 | 
						|
                autoSelect(1),
 | 
						|
                manual(2)
 | 
						|
               }
 | 
						|
ScSaState ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
       "This object describes the SC State."
 | 
						|
    SYNTAX INTEGER {
 | 
						|
                inUse(1),
 | 
						|
                notInUse(2)
 | 
						|
               }
 | 
						|
 | 
						|
ConnectGuardKeyExMode ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
       "This object describes the Connect Guard Key exchange mode."
 | 
						|
    SYNTAX INTEGER {
 | 
						|
                authPasswordBasedDiffieHellman(1),
 | 
						|
                caBasedDiffieHellman(2),
 | 
						|
                ieee8021x(3)
 | 
						|
               }
 | 
						|
 | 
						|
DiffieHellmanKeyPairLength ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
       "This object describes supported length used in DiffieHellman algorithm."
 | 
						|
    SYNTAX INTEGER {
 | 
						|
                length2048(1),
 | 
						|
                length4096(2)
 | 
						|
               }
 | 
						|
 | 
						|
 | 
						|
ConnectGuardFlowActionType ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION
 | 
						|
        "The action on mac sec flow."
 | 
						|
    SYNTAX       INTEGER {
 | 
						|
                   noAction (1),
 | 
						|
                   restartKeyXchg (2)
 | 
						|
                 }
 | 
						|
 | 
						|
--
 | 
						|
--  Connect Guard Flow Table
 | 
						|
--
 | 
						|
f3ConnectGuardFlowTable  OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF F3ConnectGuardFlowEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A list of entries for the Connect Guard flow."
 | 
						|
    ::= { f3ConnectGuardConfigObjects 1 }
 | 
						|
 | 
						|
f3ConnectGuardFlowEntry  OBJECT-TYPE
 | 
						|
    SYNTAX      F3ConnectGuardFlowEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A conceptual row in the f3ConnectGuardFlowTable."
 | 
						|
    INDEX { neIndex, f3ConnectGuardFlowIndex }
 | 
						|
    ::= { f3ConnectGuardFlowTable 1 }
 | 
						|
 | 
						|
F3ConnectGuardFlowEntry ::= SEQUENCE {
 | 
						|
    f3ConnectGuardFlowIndex                                   Integer32,
 | 
						|
    f3ConnectGuardFlowCipherSuite                             CipherSuiteType,
 | 
						|
    f3ConnectGuardFlowAdminState                              AdminState,
 | 
						|
    f3ConnectGuardFlowSecondaryState                          SecondaryState,
 | 
						|
    f3ConnectGuardFlowOperationalState                        OperationalState,
 | 
						|
    f3ConnectGuardFlowEgressInterface                         VariablePointer,
 | 
						|
    f3ConnectGuardFlowKeyExchangeProfile                      VariablePointer,
 | 
						|
    f3ConnectGuardFlowKeyExchangeFrameTagControl              KeyExchangeFrameTagControl,
 | 
						|
    f3ConnectGuardFlowKeyExchangeFrameOuterVlanEnabled        TruthValue,
 | 
						|
    f3ConnectGuardFlowKeyExchangeFrameOuterVlanId             VlanId,
 | 
						|
    f3ConnectGuardFlowKeyExchangeFrameOuterVlanPriority       VlanPriority,
 | 
						|
    f3ConnectGuardFlowKeyExchangeFrameInner1VlanEnabled       TruthValue,
 | 
						|
    f3ConnectGuardFlowKeyExchangeFrameInner1VlanId            VlanId,
 | 
						|
    f3ConnectGuardFlowKeyExchangeFrameInner1VlanPriority      VlanPriority,
 | 
						|
    f3ConnectGuardFlowKeyExchangeFrameInner2VlanEnabled       TruthValue,
 | 
						|
    f3ConnectGuardFlowKeyExchangeFrameInner2VlanId            VlanId,
 | 
						|
    f3ConnectGuardFlowKeyExchangeFrameInner2VlanPriority      VlanPriority,
 | 
						|
    f3ConnectGuardFlowKeyExchangeInterval                     Integer32,
 | 
						|
    f3ConnectGuardFlowTagsClear                               Integer32,    
 | 
						|
    f3ConnectGuardFlowStorageType                             StorageType,
 | 
						|
    f3ConnectGuardFlowRowStatus                               RowStatus,
 | 
						|
    f3ConnectGuardFlowKeyXchgFailsCounts                      Unsigned32,
 | 
						|
    f3ConnectGuardFlowAction                                  ConnectGuardFlowActionType,
 | 
						|
    f3ConnectGuardFlowReplayProtectionEnabled                 TruthValue,
 | 
						|
    f3ConnectGuardFlowReplayProtectionWindow                  Unsigned32,
 | 
						|
    f3ConnectGuardFlowRemoteMacAddrEnabled                    TruthValue,
 | 
						|
    f3ConnectGuardFlowRemoteMacAddr                           MacAddress,
 | 
						|
    f3ConnectGuardFlowAssociatedMep                           VariablePointer,
 | 
						|
    f3ConnectGuardFlowAlias                                   DisplayString,
 | 
						|
    f3ConnectGuardFlowKeyExchangeFrameOuterVlanEtherType      Unsigned32,
 | 
						|
    f3ConnectGuardFlowKeyExchangeFrameInner1VlanEtherType     Unsigned32,
 | 
						|
    f3ConnectGuardFlowKeyExchangeFrameInner2VlanEtherType     Unsigned32,
 | 
						|
    f3ConnectGuardFlowKeyInjectFlowPoint                      VariablePointer
 | 
						|
}
 | 
						|
 | 
						|
f3ConnectGuardFlowIndex OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "The index of the Connect Guard flow entry."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 1 }
 | 
						|
 | 
						|
f3ConnectGuardFlowCipherSuite OBJECT-TYPE
 | 
						|
    SYNTAX      CipherSuiteType
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object defines the cipher suite type for this flow."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 2 }
 | 
						|
 | 
						|
f3ConnectGuardFlowAdminState OBJECT-TYPE
 | 
						|
    SYNTAX      AdminState
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object represents the Administrative State of the Flow."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 3 }
 | 
						|
 | 
						|
f3ConnectGuardFlowSecondaryState OBJECT-TYPE
 | 
						|
    SYNTAX      SecondaryState
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object represents the Secondary State of the Flow."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 4 }
 | 
						|
 | 
						|
f3ConnectGuardFlowOperationalState OBJECT-TYPE
 | 
						|
    SYNTAX      OperationalState
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object represents the Operational State of the Flow."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 5 }
 | 
						|
 | 
						|
f3ConnectGuardFlowEgressInterface OBJECT-TYPE
 | 
						|
    SYNTAX      VariablePointer
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object defines the Connect Guard Flow egress interface."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 6 }
 | 
						|
 | 
						|
f3ConnectGuardFlowKeyExchangeProfile OBJECT-TYPE
 | 
						|
    SYNTAX      VariablePointer
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object defines the key exchange profile to be used for the secure flow."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 7 }
 | 
						|
 | 
						|
f3ConnectGuardFlowKeyExchangeFrameTagControl OBJECT-TYPE
 | 
						|
    SYNTAX      KeyExchangeFrameTagControl
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object defines the key exchange frame tag mode."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 8 }
 | 
						|
 | 
						|
f3ConnectGuardFlowKeyExchangeFrameOuterVlanEnabled OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object controls the key exchange frame Outer Vlan."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 9 }
 | 
						|
 | 
						|
f3ConnectGuardFlowKeyExchangeFrameOuterVlanId OBJECT-TYPE
 | 
						|
    SYNTAX      VlanId
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object defines the key exchange frame outer Vlan ID"
 | 
						|
    ::= { f3ConnectGuardFlowEntry 10 }
 | 
						|
 | 
						|
f3ConnectGuardFlowKeyExchangeFrameOuterVlanPriority OBJECT-TYPE
 | 
						|
    SYNTAX      VlanPriority
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object defines the key exchange frame outer Vlan Priority."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 11 }
 | 
						|
 | 
						|
f3ConnectGuardFlowKeyExchangeFrameInner1VlanEnabled OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object controls the key exchange frame Inner Vlan."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 12 }
 | 
						|
 | 
						|
f3ConnectGuardFlowKeyExchangeFrameInner1VlanId OBJECT-TYPE
 | 
						|
    SYNTAX      VlanId
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object defines the key exchange frame Inner Vlan ID"
 | 
						|
    ::= { f3ConnectGuardFlowEntry 13 }
 | 
						|
 | 
						|
f3ConnectGuardFlowKeyExchangeFrameInner1VlanPriority OBJECT-TYPE
 | 
						|
    SYNTAX      VlanPriority
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object defines the key exchange frame Inner Vlan Priority."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 14 }
 | 
						|
 | 
						|
f3ConnectGuardFlowKeyExchangeFrameInner2VlanEnabled OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object controls the key exchange frame Inner most Vlan."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 15 }
 | 
						|
 | 
						|
f3ConnectGuardFlowKeyExchangeFrameInner2VlanId OBJECT-TYPE
 | 
						|
    SYNTAX      VlanId
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object defines the key exchange frame Inner most Vlan ID"
 | 
						|
    ::= { f3ConnectGuardFlowEntry 16 }
 | 
						|
 | 
						|
f3ConnectGuardFlowKeyExchangeFrameInner2VlanPriority OBJECT-TYPE
 | 
						|
    SYNTAX      VlanPriority
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object defines the key exchange frame Inner most Vlan Priority."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 17 }
 | 
						|
 | 
						|
 | 
						|
f3ConnectGuardFlowKeyExchangeInterval OBJECT-TYPE
 | 
						|
    SYNTAX     Integer32
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "This object defines the key exchange interval value, in one minute increment"
 | 
						|
    ::= { f3ConnectGuardFlowEntry 18 }
 | 
						|
 | 
						|
f3ConnectGuardFlowTagsClear OBJECT-TYPE
 | 
						|
    SYNTAX     Integer32
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "This object defines the number of tags to by pass in encryption"
 | 
						|
    ::= { f3ConnectGuardFlowEntry 19 }
 | 
						|
 | 
						|
f3ConnectGuardFlowStorageType OBJECT-TYPE
 | 
						|
    SYNTAX     StorageType
 | 
						|
    MAX-ACCESS read-create
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "The type of storage configured for this entry."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 20 }
 | 
						|
 | 
						|
f3ConnectGuardFlowRowStatus OBJECT-TYPE
 | 
						|
    SYNTAX      RowStatus
 | 
						|
    MAX-ACCESS  read-create
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "The status of this row.
 | 
						|
            An entry MUST NOT exist in the active state unless all
 | 
						|
            objects in the entry have an appropriate value, as described
 | 
						|
            in the description clause for each writable object.
 | 
						|
 | 
						|
            The values of f3ConnectGuardFlowRowStatus supported are
 | 
						|
            createAndGo(4) and destroy(6).  All mandatory attributes
 | 
						|
            must be specified in a single SNMP SET request with
 | 
						|
            f3ConnectGuardFlowRowStatus value as createAndGo(4).
 | 
						|
            Upon successful row creation, this variable has a
 | 
						|
            value of active(1).
 | 
						|
 | 
						|
            The f3ConnectGuardFlowRowStatus object may be modified if
 | 
						|
            the associated instance of this object is equal to active(1)."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 21 }
 | 
						|
 | 
						|
f3ConnectGuardFlowKeyXchgFailsCounts OBJECT-TYPE
 | 
						|
    SYNTAX     Unsigned32
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "This object counts number of times key exchange protocol failed."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 22 }
 | 
						|
 | 
						|
f3ConnectGuardFlowAction OBJECT-TYPE
 | 
						|
    SYNTAX     ConnectGuardFlowActionType
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "This object describe operation on the Connect Guard flow."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 23 }
 | 
						|
 | 
						|
f3ConnectGuardFlowReplayProtectionEnabled OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object can be used to enable/disable replay proctection."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 24 }
 | 
						|
 | 
						|
f3ConnectGuardFlowReplayProtectionWindow OBJECT-TYPE
 | 
						|
    SYNTAX      Unsigned32
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object defines replay proctection window value."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 25 }
 | 
						|
 | 
						|
f3ConnectGuardFlowRemoteMacAddrEnabled OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object can be used to enable/disable remote MAC Address that used as the destination MAC address in the 
 | 
						|
            key exchange protocol packets."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 26 }
 | 
						|
 | 
						|
f3ConnectGuardFlowRemoteMacAddr OBJECT-TYPE
 | 
						|
    SYNTAX      MacAddress
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object defines remote MAC Address value."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 27 }
 | 
						|
 | 
						|
 | 
						|
f3ConnectGuardFlowAssociatedMep OBJECT-TYPE
 | 
						|
    SYNTAX      VariablePointer
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object speicify the mep object to use as trigger for key exchange failure"
 | 
						|
    ::= { f3ConnectGuardFlowEntry 28 }
 | 
						|
 | 
						|
 | 
						|
f3ConnectGuardFlowAlias OBJECT-TYPE
 | 
						|
    SYNTAX      DisplayString (SIZE(0..64))
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "This object speicify the connect guard flow's alias."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 29 }
 | 
						|
 | 
						|
f3ConnectGuardFlowKeyExchangeFrameOuterVlanEtherType  OBJECT-TYPE
 | 
						|
     SYNTAX      Unsigned32
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
           "Outer vlan ether type used in key exchange."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 30 }
 | 
						|
 | 
						|
f3ConnectGuardFlowKeyExchangeFrameInner1VlanEtherType  OBJECT-TYPE
 | 
						|
     SYNTAX      Unsigned32
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
           "Inner1 vlan ether type used in key exchange."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 31 }
 | 
						|
 | 
						|
f3ConnectGuardFlowKeyExchangeFrameInner2VlanEtherType  OBJECT-TYPE
 | 
						|
     SYNTAX      Unsigned32
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
           "Inner2 vlan ether type used in key exchange."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 32 }
 | 
						|
 | 
						|
f3ConnectGuardFlowKeyInjectFlowPoint  OBJECT-TYPE
 | 
						|
     SYNTAX      VariablePointer
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
           "Pointer to a flowpoint used to up inject key exchange frames in case of ERP."
 | 
						|
    ::= { f3ConnectGuardFlowEntry 33 }
 | 
						|
 | 
						|
--
 | 
						|
--  Key Exchange Profile Table
 | 
						|
--
 | 
						|
f3ConnectGuardKeyExchangeProfileTable  OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF F3ConnectGuardKeyExchangeProfileEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A list of entries for the key exchange profile."
 | 
						|
    ::= { f3ConnectGuardConfigObjects 2 }
 | 
						|
 | 
						|
f3ConnectGuardKeyExchangeProfileEntry  OBJECT-TYPE
 | 
						|
    SYNTAX      F3ConnectGuardKeyExchangeProfileEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A conceptual row in the f3ConnectGuardKeyExchangeProfileTable."
 | 
						|
    INDEX { f3ConnectGuardKeyExchangeProfileIndex }
 | 
						|
    ::= { f3ConnectGuardKeyExchangeProfileTable 1 }
 | 
						|
 | 
						|
F3ConnectGuardKeyExchangeProfileEntry ::= SEQUENCE {
 | 
						|
    f3ConnectGuardKeyExchangeProfileIndex                     Integer32,
 | 
						|
    f3ConnectGuardKeyExchangeProfileName                      DisplayString,
 | 
						|
    f3ConnectGuardKeyExchangeProfileUserId                    DisplayString,
 | 
						|
    f3ConnectGuardKeyExchangeProfileMode                      ConnectGuardKeyExMode,
 | 
						|
    f3ConnectGuardKeyExchangeProfileAuthPassword              DisplayString,
 | 
						|
    f3ConnectGuardKeyExchangeProfileDiffieHellmanKeyPairLen   DiffieHellmanKeyPairLength,
 | 
						|
    f3ConnectGuardKeyExchangeProfileStorageType               StorageType,
 | 
						|
    f3ConnectGuardKeyExchangeProfileRowStatus                 RowStatus  
 | 
						|
}
 | 
						|
 | 
						|
f3ConnectGuardKeyExchangeProfileIndex OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "The index of the key exchange profile."
 | 
						|
    ::= { f3ConnectGuardKeyExchangeProfileEntry 1 }
 | 
						|
 | 
						|
f3ConnectGuardKeyExchangeProfileName OBJECT-TYPE
 | 
						|
    SYNTAX      DisplayString
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "The name of this profile."
 | 
						|
    ::= { f3ConnectGuardKeyExchangeProfileEntry 2 }
 | 
						|
 | 
						|
f3ConnectGuardKeyExchangeProfileUserId OBJECT-TYPE
 | 
						|
    SYNTAX      DisplayString
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "The user name who created this profile. It is automatically set by the system."
 | 
						|
    ::= { f3ConnectGuardKeyExchangeProfileEntry 3 }
 | 
						|
 | 
						|
f3ConnectGuardKeyExchangeProfileMode OBJECT-TYPE
 | 
						|
    SYNTAX      ConnectGuardKeyExMode
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "The key exchange mode."
 | 
						|
    ::= { f3ConnectGuardKeyExchangeProfileEntry 4 }
 | 
						|
 | 
						|
f3ConnectGuardKeyExchangeProfileAuthPassword OBJECT-TYPE
 | 
						|
    SYNTAX      DisplayString
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "The authentication password for this profile."
 | 
						|
    ::= { f3ConnectGuardKeyExchangeProfileEntry 5 }
 | 
						|
 | 
						|
f3ConnectGuardKeyExchangeProfileDiffieHellmanKeyPairLen OBJECT-TYPE
 | 
						|
    SYNTAX      DiffieHellmanKeyPairLength
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "The Diffie-Hellman key pair length for this profile."
 | 
						|
    ::= { f3ConnectGuardKeyExchangeProfileEntry 6 }
 | 
						|
 | 
						|
f3ConnectGuardKeyExchangeProfileStorageType OBJECT-TYPE
 | 
						|
    SYNTAX     StorageType
 | 
						|
    MAX-ACCESS read-create
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "The type of storage configured for this entry."
 | 
						|
    ::= { f3ConnectGuardKeyExchangeProfileEntry 7 }
 | 
						|
 | 
						|
f3ConnectGuardKeyExchangeProfileRowStatus OBJECT-TYPE
 | 
						|
    SYNTAX      RowStatus
 | 
						|
    MAX-ACCESS  read-create
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "The status of this row.
 | 
						|
            An entry MUST NOT exist in the active state unless all
 | 
						|
            objects in the entry have an appropriate value, as described
 | 
						|
            in the description clause for each writable object.
 | 
						|
 | 
						|
            The values of f3ConnectGuardKeyExchangeProfileRowStatus supported are
 | 
						|
            createAndGo(4) and destroy(6).  All mandatory attributes
 | 
						|
            must be specified in a single SNMP SET request with
 | 
						|
            f3ConnectGuardKeyExchangeProfileRowStatus value as createAndGo(4).
 | 
						|
            Upon successful row creation, this variable has a
 | 
						|
            value of active(1).
 | 
						|
 | 
						|
            The f3ConnectGuardKeyExchangeProfileRowStatus object may be modified if
 | 
						|
            the associated instance of this object is equal to active(1)."
 | 
						|
    ::= { f3ConnectGuardKeyExchangeProfileEntry 8 }
 | 
						|
 | 
						|
--
 | 
						|
--  TX SC Table
 | 
						|
--
 | 
						|
f3ConnectGuardTxSCTable  OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF F3ConnectGuardTxSCEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A list of entries for the Connect Guard TX SC."
 | 
						|
    ::= { f3ConnectGuardConfigObjects 3 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCEntry  OBJECT-TYPE
 | 
						|
    SYNTAX      F3ConnectGuardTxSCEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A conceptual row in the f3ConnectGuardTxSCTable."
 | 
						|
    INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardTxSCIndex }
 | 
						|
    ::= { f3ConnectGuardTxSCTable 1 }
 | 
						|
 | 
						|
F3ConnectGuardTxSCEntry ::= SEQUENCE {
 | 
						|
    f3ConnectGuardTxSCIndex                               Integer32,
 | 
						|
    f3ConnectGuardTxSCI                                   SecySCI,
 | 
						|
    f3ConnectGuardTxScState                               ScSaState,
 | 
						|
    f3ConnectGuardCurrentTxSa                             Integer32,
 | 
						|
    f3ConnectGuardPreviousTxSa                            Integer32,
 | 
						|
    f3ConnectGuardTxScCreateTime                          DateAndTime,
 | 
						|
    f3ConnectGuardTxScStartTime                           DateAndTime,
 | 
						|
    f3ConnectGuardTxScStopTime                            DateAndTime
 | 
						|
}
 | 
						|
 | 
						|
f3ConnectGuardTxSCIndex OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "The index of the Connect Guard TX SC entry."
 | 
						|
    ::= { f3ConnectGuardTxSCEntry 1 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCI OBJECT-TYPE
 | 
						|
    SYNTAX      SecySCI
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "The index of the Connect Guard TX SCI."
 | 
						|
    ::= { f3ConnectGuardTxSCEntry 2 }
 | 
						|
 | 
						|
f3ConnectGuardTxScState OBJECT-TYPE
 | 
						|
    SYNTAX     ScSaState
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "This object defines the Tx Sc State."
 | 
						|
    ::= { f3ConnectGuardTxSCEntry 3 }
 | 
						|
 | 
						|
f3ConnectGuardCurrentTxSa OBJECT-TYPE
 | 
						|
    SYNTAX     Integer32
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "This object defines the AN number of current Tx SA.
 | 
						|
            -1 means no current Tx SA."
 | 
						|
    ::= { f3ConnectGuardTxSCEntry 4 }
 | 
						|
 | 
						|
f3ConnectGuardPreviousTxSa OBJECT-TYPE
 | 
						|
    SYNTAX     Integer32
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "This object defines the AN number of previous Tx SA.
 | 
						|
            -1 means no previous Tx SA."
 | 
						|
    ::= { f3ConnectGuardTxSCEntry 5 }
 | 
						|
 | 
						|
f3ConnectGuardTxScCreateTime OBJECT-TYPE
 | 
						|
    SYNTAX     DateAndTime
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "This object defines the system time when the SC was created."
 | 
						|
    ::= { f3ConnectGuardTxSCEntry 6 }
 | 
						|
 | 
						|
f3ConnectGuardTxScStartTime OBJECT-TYPE
 | 
						|
    SYNTAX     DateAndTime
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "The system time when this transmitting SC last started
 | 
						|
 	           transmitting Connect Guard frames."
 | 
						|
    ::= { f3ConnectGuardTxSCEntry 7 }
 | 
						|
 | 
						|
f3ConnectGuardTxScStopTime OBJECT-TYPE
 | 
						|
    SYNTAX     DateAndTime
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "The system time when this transmitting SC last stopped
 | 
						|
 	           transmitting Connect Guard frames."
 | 
						|
    ::= { f3ConnectGuardTxSCEntry 8}
 | 
						|
 | 
						|
--
 | 
						|
--  RX SC Table
 | 
						|
--
 | 
						|
f3ConnectGuardRxSCTable  OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF F3ConnectGuardRxSCEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A list of entries for the Connect Guard RX SC."
 | 
						|
    ::= { f3ConnectGuardConfigObjects 4 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCEntry  OBJECT-TYPE
 | 
						|
    SYNTAX      F3ConnectGuardRxSCEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A conceptual row in the f3ConnectGuardRxSCTable."
 | 
						|
    INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardRxSCIndex }
 | 
						|
    ::= { f3ConnectGuardRxSCTable 1 }
 | 
						|
 | 
						|
F3ConnectGuardRxSCEntry ::= SEQUENCE {
 | 
						|
    f3ConnectGuardRxSCIndex             Integer32,
 | 
						|
    f3ConnectGuardRxSCI                 SecySCI,
 | 
						|
    f3ConnectGuardRxScState             ScSaState,
 | 
						|
    f3ConnectGuardCurrentRxSa           Integer32,
 | 
						|
    f3ConnectGuardRxScCreateTime        DateAndTime,
 | 
						|
    f3ConnectGuardRxScStartTime         DateAndTime,
 | 
						|
    f3ConnectGuardRxScStopTime          DateAndTime
 | 
						|
}
 | 
						|
 | 
						|
f3ConnectGuardRxSCIndex OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "The RX SC number."
 | 
						|
    ::= { f3ConnectGuardRxSCEntry 1 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCI OBJECT-TYPE
 | 
						|
    SYNTAX      SecySCI
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
           "The SCI value, includes 8 bytes."
 | 
						|
    ::= { f3ConnectGuardRxSCEntry 2 }
 | 
						|
 | 
						|
f3ConnectGuardRxScState OBJECT-TYPE
 | 
						|
    SYNTAX     ScSaState
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "The state of the receiving SC in the SecY.
 | 
						|
            inUse(1) : means any of SAs for this SC is in use.
 | 
						|
            notInUse(2) : means no SAs for this SC is in use."
 | 
						|
    ::= { f3ConnectGuardRxSCEntry 3}
 | 
						|
 | 
						|
f3ConnectGuardCurrentRxSa OBJECT-TYPE
 | 
						|
    SYNTAX     Integer32
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "The AN number of current Rx SA, -1 means no current Rx SA."
 | 
						|
    ::= { f3ConnectGuardRxSCEntry 4}
 | 
						|
 | 
						|
f3ConnectGuardRxScCreateTime OBJECT-TYPE
 | 
						|
    SYNTAX     DateAndTime
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "The system time when this receiving SC was created."
 | 
						|
    ::= { f3ConnectGuardRxSCEntry 5 }
 | 
						|
 | 
						|
f3ConnectGuardRxScStartTime OBJECT-TYPE
 | 
						|
    SYNTAX     DateAndTime
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "The system time when this receiving SC last started
 | 
						|
             receiving ConnectGuard frames."
 | 
						|
    ::= { f3ConnectGuardRxSCEntry 6 }
 | 
						|
 | 
						|
f3ConnectGuardRxScStopTime OBJECT-TYPE
 | 
						|
    SYNTAX     DateAndTime
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "The system time when this receiving SC last stopped
 | 
						|
             receiving ConnectGuard frames."
 | 
						|
    ::= { f3ConnectGuardRxSCEntry 7}
 | 
						|
 | 
						|
--
 | 
						|
-- Tx SA Management Table
 | 
						|
--
 | 
						|
 | 
						|
f3ConnectGuardTxSATable    OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF F3ConnectGuardTxSAEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "A table for providing information about the status of each
 | 
						|
         transmitting SA supported by the MAC security entity."
 | 
						|
    REFERENCE
 | 
						|
        "IEEE 802.1AE Clause 10.7.21"
 | 
						|
    ::= { f3ConnectGuardConfigObjects 5 }
 | 
						|
 | 
						|
f3ConnectGuardTxSAEntry    OBJECT-TYPE
 | 
						|
    SYNTAX      F3ConnectGuardTxSAEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "An entry containing transmitting SA management information
 | 
						|
         applicable to a particular SA."
 | 
						|
    INDEX   { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardTxSCIndex, f3ConnectGuardTxSAIndex } 
 | 
						|
    ::= { f3ConnectGuardTxSATable 1 }
 | 
						|
 | 
						|
F3ConnectGuardTxSAEntry ::= SEQUENCE {
 | 
						|
    f3ConnectGuardTxSAIndex              Unsigned32,
 | 
						|
    f3ConnectGuardTxSAState              INTEGER,
 | 
						|
    f3ConnectGuardTxSANextPN             Unsigned32,
 | 
						|
    f3ConnectGuardTxSASAKUnchanged       TruthValue,
 | 
						|
    f3ConnectGuardTxSACreatedTime        DateAndTime,
 | 
						|
    f3ConnectGuardTxSAStartedTime        DateAndTime,
 | 
						|
    f3ConnectGuardTxSAStoppedTime        DateAndTime
 | 
						|
}
 | 
						|
 | 
						|
f3ConnectGuardTxSAIndex    OBJECT-TYPE
 | 
						|
    SYNTAX      Unsigned32
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The association number (AN) for identifying a transmitting
 | 
						|
         SA."
 | 
						|
    REFERENCE
 | 
						|
        "IEEE 802.1AE Clause 10.7.21"
 | 
						|
    ::= { f3ConnectGuardTxSAEntry 1 }
 | 
						|
 | 
						|
f3ConnectGuardTxSAState    OBJECT-TYPE
 | 
						|
    SYNTAX      ScSaState
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The current status of the transmitting SA.
 | 
						|
         inUse(1) : means this SA is in use.
 | 
						|
         notInUse(2) : means this SA is not in use."
 | 
						|
    REFERENCE
 | 
						|
        "IEEE 802.1AE Clause 10.7.22"
 | 
						|
    ::= { f3ConnectGuardTxSAEntry 2 }
 | 
						|
 | 
						|
f3ConnectGuardTxSANextPN    OBJECT-TYPE
 | 
						|
    SYNTAX      Unsigned32
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The next packet number (PN) that will be used in transmitting
 | 
						|
         ConnectGuard frames in the SA."
 | 
						|
    REFERENCE
 | 
						|
        "IEEE 802.1AE Clause 10.7.21"
 | 
						|
    ::= { f3ConnectGuardTxSAEntry 3 }
 | 
						|
 | 
						|
f3ConnectGuardTxSASAKUnchanged    OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "A reference to an SAK that is unchanged for the life
 | 
						|
         of the transmitting SA."
 | 
						|
    REFERENCE
 | 
						|
        "IEEE 802.1AE Clause 10.7.21"
 | 
						|
    ::= { f3ConnectGuardTxSAEntry 4 }
 | 
						|
 | 
						|
f3ConnectGuardTxSACreatedTime    OBJECT-TYPE
 | 
						|
    SYNTAX      DateAndTime
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The system time when this transmitting SA was created."
 | 
						|
    REFERENCE
 | 
						|
        "IEEE 802.1AE Clause 10.7.22"
 | 
						|
    ::= { f3ConnectGuardTxSAEntry 5 }
 | 
						|
 | 
						|
f3ConnectGuardTxSAStartedTime    OBJECT-TYPE
 | 
						|
    SYNTAX      DateAndTime
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The system time when this transmitting SA last started
 | 
						|
         transmitting ConnectGuard frames."
 | 
						|
    REFERENCE
 | 
						|
        "IEEE 802.1AE Clause 10.7.22"
 | 
						|
    ::= { f3ConnectGuardTxSAEntry 6 }
 | 
						|
 | 
						|
f3ConnectGuardTxSAStoppedTime    OBJECT-TYPE
 | 
						|
    SYNTAX      DateAndTime
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The system time when this transmitting SA last stopped
 | 
						|
         transmitting ConnectGuard frames."
 | 
						|
    REFERENCE
 | 
						|
        "IEEE 802.1AE Clause 10.7.22"
 | 
						|
    ::= { f3ConnectGuardTxSAEntry 7 }
 | 
						|
 | 
						|
--
 | 
						|
-- Rx SA Management Table
 | 
						|
--
 | 
						|
 | 
						|
f3ConnectGuardRxSATable    OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF F3ConnectGuardRxSAEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "A table for providing information about the status of each
 | 
						|
         transmitting SA supported by the MAC security entity."
 | 
						|
    REFERENCE
 | 
						|
        "IEEE 802.1AE Clause 10.7.21"
 | 
						|
    ::= { f3ConnectGuardConfigObjects 6 }
 | 
						|
 | 
						|
f3ConnectGuardRxSAEntry    OBJECT-TYPE
 | 
						|
    SYNTAX      F3ConnectGuardRxSAEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "An entry containing transmitting SA management information
 | 
						|
         applicable to a particular SA."
 | 
						|
    INDEX   { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardRxSCIndex, f3ConnectGuardRxSAIndex } 
 | 
						|
    ::= { f3ConnectGuardRxSATable 1 }
 | 
						|
 | 
						|
F3ConnectGuardRxSAEntry ::= SEQUENCE {
 | 
						|
    f3ConnectGuardRxSAIndex              Unsigned32,
 | 
						|
    f3ConnectGuardRxSAState              INTEGER,
 | 
						|
    f3ConnectGuardRxSANextPN             Unsigned32,
 | 
						|
    f3ConnectGuardRxSASAKUnchanged       TruthValue,
 | 
						|
    f3ConnectGuardRxSACreatedTime        DateAndTime,
 | 
						|
    f3ConnectGuardRxSAStartedTime        DateAndTime,
 | 
						|
    f3ConnectGuardRxSAStoppedTime        DateAndTime
 | 
						|
}
 | 
						|
 | 
						|
f3ConnectGuardRxSAIndex    OBJECT-TYPE
 | 
						|
    SYNTAX      Unsigned32
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The association number (AN) for identifying a transmitting
 | 
						|
         SA."
 | 
						|
    REFERENCE
 | 
						|
        "IEEE 802.1AE Clause 10.7.21"
 | 
						|
    ::= { f3ConnectGuardRxSAEntry 1 }
 | 
						|
 | 
						|
f3ConnectGuardRxSAState    OBJECT-TYPE
 | 
						|
    SYNTAX      ScSaState
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The current status of the transmitting SA.
 | 
						|
         inUse(1) : means this SA is in use.
 | 
						|
         notInUse(2) : means this SA is not in use."
 | 
						|
    REFERENCE
 | 
						|
        "IEEE 802.1AE Clause 10.7.22"
 | 
						|
    ::= { f3ConnectGuardRxSAEntry 2 }
 | 
						|
 | 
						|
f3ConnectGuardRxSANextPN    OBJECT-TYPE
 | 
						|
    SYNTAX      Unsigned32
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The next packet number (PN) that will be used in transmitting
 | 
						|
         ConnectGuard frames in the SA."
 | 
						|
    REFERENCE
 | 
						|
        "IEEE 802.1AE Clause 10.7.21"
 | 
						|
    ::= { f3ConnectGuardRxSAEntry 3 }
 | 
						|
 | 
						|
f3ConnectGuardRxSASAKUnchanged    OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "A reference to an SAK that is unchanged for the life
 | 
						|
         of the transmitting SA."
 | 
						|
    REFERENCE
 | 
						|
        "IEEE 802.1AE Clause 10.7.21"
 | 
						|
    ::= { f3ConnectGuardRxSAEntry 4 }
 | 
						|
 | 
						|
f3ConnectGuardRxSACreatedTime    OBJECT-TYPE
 | 
						|
    SYNTAX      DateAndTime
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The system time when this transmitting SA was created."
 | 
						|
    REFERENCE
 | 
						|
        "IEEE 802.1AE Clause 10.7.22"
 | 
						|
    ::= { f3ConnectGuardRxSAEntry 5 }
 | 
						|
 | 
						|
f3ConnectGuardRxSAStartedTime    OBJECT-TYPE
 | 
						|
    SYNTAX      DateAndTime
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The system time when this transmitting SA last started
 | 
						|
         transmitting ConnectGuard frames."
 | 
						|
    REFERENCE
 | 
						|
        "IEEE 802.1AE Clause 10.7.22"
 | 
						|
    ::= { f3ConnectGuardRxSAEntry 6 }
 | 
						|
 | 
						|
f3ConnectGuardRxSAStoppedTime    OBJECT-TYPE
 | 
						|
    SYNTAX      DateAndTime
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
        "The system time when this transmitting SA last stopped
 | 
						|
         transmitting ConnectGuard frames."
 | 
						|
    REFERENCE
 | 
						|
        "IEEE 802.1AE Clause 10.7.22"
 | 
						|
    ::= { f3ConnectGuardRxSAEntry 7 }
 | 
						|
 | 
						|
--
 | 
						|
-- flow extension Table
 | 
						|
--
 | 
						|
f3FlowExtConnectGuardTable OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF F3FlowExtConnectGuardEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      deprecated
 | 
						|
    DESCRIPTION
 | 
						|
            "A list of entries corresponding to Flow for configuration purposes.
 | 
						|
             This table has been deprecated. Attributes have been moved to 
 | 
						|
             cmFlowTable."
 | 
						|
    ::= { f3ConnectGuardConfigObjects 7 }
 | 
						|
 | 
						|
f3FlowExtConnectGuardEntry OBJECT-TYPE
 | 
						|
    SYNTAX      F3FlowExtConnectGuardEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      deprecated
 | 
						|
    DESCRIPTION
 | 
						|
            "A conceptual row in the f3FlowExtConnectGuardTable."
 | 
						|
    AUGMENTS { cmFlowEntry }
 | 
						|
    ::= { f3FlowExtConnectGuardTable 1 }
 | 
						|
 | 
						|
F3FlowExtConnectGuardEntry ::= SEQUENCE {
 | 
						|
    f3FlowRefConnectGuardFlowObject       VariablePointer,
 | 
						|
    f3FlowSecureBlockingEnabled           TruthValue,
 | 
						|
    f3FlowSecureState                     FlowSecureState
 | 
						|
}
 | 
						|
 | 
						|
f3FlowRefConnectGuardFlowObject OBJECT-TYPE
 | 
						|
    SYNTAX     VariablePointer
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
          "This object specifies Mac Sec flow object OID."
 | 
						|
     ::= { f3FlowExtConnectGuardEntry 1 }
 | 
						|
 | 
						|
f3FlowSecureBlockingEnabled OBJECT-TYPE
 | 
						|
    SYNTAX     TruthValue
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
          "This object can be used to enable/disable secure block."
 | 
						|
     ::= { f3FlowExtConnectGuardEntry 2 }
 | 
						|
 | 
						|
f3FlowSecureState OBJECT-TYPE
 | 
						|
    SYNTAX     FlowSecureState
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
          "This object specifies the secure state of this flow."
 | 
						|
     ::= { f3FlowExtConnectGuardEntry 3 }
 | 
						|
 | 
						|
f3ConnectGuardConfigScalars    OBJECT IDENTIFIER ::= {f3ConnectGuardConfigObjects 8}
 | 
						|
f3ConnectGuardPasswordScalars  OBJECT IDENTIFIER ::= {f3ConnectGuardConfigObjects 9}
 | 
						|
 | 
						|
f3ConnectGuardCryptoPassword OBJECT-TYPE
 | 
						|
    SYNTAX     DisplayString
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "This is the second level password for the crypto user. 
 | 
						|
        This password is required to modify ConnectGuard objects. 
 | 
						|
        Every set request that involves a ConnectGuard object should 
 | 
						|
        include this variable with correct password value to succeed."
 | 
						|
    ::= { f3ConnectGuardPasswordScalars 1 }
 | 
						|
 | 
						|
f3ConnectGuardRestoreFactoryApproved OBJECT-TYPE
 | 
						|
    SYNTAX     TruthValue
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "Crypto user can use this object to enable/disable restore factory defaults on the NID."
 | 
						|
    ::= { f3ConnectGuardConfigScalars 1 }
 | 
						|
 | 
						|
f3ConnectGuardSoftwareVersionApproved OBJECT-TYPE
 | 
						|
    SYNTAX     DisplayString
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "This object describes the software version that crypto user approved for upgrade."
 | 
						|
    ::= { f3ConnectGuardConfigScalars 2 }
 | 
						|
 | 
						|
f3ConnectGuardSoftwareInstallApproved OBJECT-TYPE
 | 
						|
    SYNTAX     TruthValue
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "Crypto user can use this object to enable/disable sofware install on the NID."
 | 
						|
    ::= { f3ConnectGuardConfigScalars 3 }
 | 
						|
 | 
						|
f3ConnectGuardRestoreDatabaseApproved OBJECT-TYPE
 | 
						|
    SYNTAX     TruthValue
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "Crypto user can use this object to enable/disable restore database on the NID."
 | 
						|
    ::= { f3ConnectGuardConfigScalars 4 }
 | 
						|
 | 
						|
f3ConnectGuardConfigFileLoadApproved OBJECT-TYPE
 | 
						|
    SYNTAX     TruthValue
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "Crypto user can use this object to enable/disable config file operation on the NID."
 | 
						|
    ::= { f3ConnectGuardConfigScalars 5 }
 | 
						|
 | 
						|
f3ConnectGuardCryptoPasswordControl OBJECT-TYPE
 | 
						|
    SYNTAX     TruthValue
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "A system level attribute to disable/enable crypto password request when changing ConnectGuard attributes."
 | 
						|
    ::= { f3ConnectGuardConfigScalars 6 }
 | 
						|
 | 
						|
--
 | 
						|
-- PERFORMANCE 
 | 
						|
--
 | 
						|
 | 
						|
--
 | 
						|
-- Mac Sec Flow Current Statistics Table
 | 
						|
--
 | 
						|
f3ConnectGuardFlowStatsTable OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF F3ConnectGuardFlowStatsEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A collection of Mac Sec Flow statistics.  
 | 
						|
             These reflect the current data."
 | 
						|
    ::= { f3ConnectGuardPerformanceObjects 1 }
 | 
						|
 | 
						|
f3ConnectGuardFlowStatsEntry OBJECT-TYPE
 | 
						|
    SYNTAX      F3ConnectGuardFlowStatsEntry 
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A conceptual row in the f3ConnectGuardFlowStatsTable.
 | 
						|
             Entries exist in this table for each Connect Guard Flow."
 | 
						|
    INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardFlowStatsIndex }
 | 
						|
    ::= { f3ConnectGuardFlowStatsTable 1 }
 | 
						|
 | 
						|
F3ConnectGuardFlowStatsEntry ::= SEQUENCE {
 | 
						|
    f3ConnectGuardFlowStatsIndex                     Integer32,
 | 
						|
    f3ConnectGuardFlowStatsIntervalType              CmPmIntervalType,
 | 
						|
    f3ConnectGuardFlowStatsValid                     TruthValue,
 | 
						|
    f3ConnectGuardFlowStatsAction                    CmPmBinAction,
 | 
						|
    f3ConnectGuardFlowStatsTxUntaggedPkts            PerfCounter64,
 | 
						|
    f3ConnectGuardFlowStatsTxTooLongPkts             PerfCounter64,
 | 
						|
    f3ConnectGuardFlowStatsRxUntaggedPkts            PerfCounter64,
 | 
						|
    f3ConnectGuardFlowStatsRxNotagPkts               PerfCounter64,
 | 
						|
    f3ConnectGuardFlowStatsRxBadtagPkts              PerfCounter64,
 | 
						|
    f3ConnectGuardFlowStatsRxUnknownSCIPkts          PerfCounter64,
 | 
						|
    f3ConnectGuardFlowStatsRxNoSCIPkts               PerfCounter64,
 | 
						|
    f3ConnectGuardFlowStatsRxOverrunPkts             PerfCounter64
 | 
						|
}
 | 
						|
 | 
						|
f3ConnectGuardFlowStatsIndex OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32 (1..4)
 | 
						|
    MAX-ACCESS  not-accessible 
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "An arbitrary integer index value used to uniquely identify
 | 
						|
            this Connect Guard Flow statistics entry. 
 | 
						|
            1 - 15min
 | 
						|
            2 - 1day
 | 
						|
            3 - rollover
 | 
						|
            4 - 5min"
 | 
						|
    ::= { f3ConnectGuardFlowStatsEntry 1 }
 | 
						|
 | 
						|
f3ConnectGuardFlowStatsIntervalType OBJECT-TYPE
 | 
						|
    SYNTAX      CmPmIntervalType
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Indicates the type of collection, i.e. whether it is
 | 
						|
             15 Min, 1 Day or rollover."
 | 
						|
    ::= { f3ConnectGuardFlowStatsEntry 2 }
 | 
						|
 | 
						|
f3ConnectGuardFlowStatsValid OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Indicates the validity of the bin."
 | 
						|
    ::= { f3ConnectGuardFlowStatsEntry 3 }
 | 
						|
 | 
						|
f3ConnectGuardFlowStatsAction OBJECT-TYPE
 | 
						|
    SYNTAX      CmPmBinAction
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Allows the operator to clear the bin."
 | 
						|
    ::= { f3ConnectGuardFlowStatsEntry 4 }
 | 
						|
 | 
						|
f3ConnectGuardFlowStatsTxUntaggedPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of transmitted packets without the MAC	security tag (SecTAG)."
 | 
						|
     ::= { f3ConnectGuardFlowStatsEntry 5 }
 | 
						|
 | 
						|
f3ConnectGuardFlowStatsTxTooLongPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of transmitted packets discarded because the packet
 | 
						|
 	        length is greater than the ifMtu of the Common Port interface."
 | 
						|
     ::= { f3ConnectGuardFlowStatsEntry 6 }
 | 
						|
 | 
						|
f3ConnectGuardFlowStatsRxUntaggedPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of received packets without the MAC security tag(SecTAG)."
 | 
						|
     ::= { f3ConnectGuardFlowStatsEntry 7 }
 | 
						|
 | 
						|
f3ConnectGuardFlowStatsRxNotagPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of received packets discarded without the MAC security tag (SecTAG)."
 | 
						|
     ::= { f3ConnectGuardFlowStatsEntry 8 }
 | 
						|
 | 
						|
f3ConnectGuardFlowStatsRxBadtagPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of received packets discarded with an invalid
 | 
						|
 	        SecTAG or a zero value PN or an invalid ICV."
 | 
						|
     ::= { f3ConnectGuardFlowStatsEntry 9 }
 | 
						|
 | 
						|
f3ConnectGuardFlowStatsRxUnknownSCIPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of received packets with unknown SCI."
 | 
						|
     ::= { f3ConnectGuardFlowStatsEntry 10 }
 | 
						|
 | 
						|
f3ConnectGuardFlowStatsRxNoSCIPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of received packets discarded with unknown SCI information."
 | 
						|
     ::= { f3ConnectGuardFlowStatsEntry 11 }
 | 
						|
 | 
						|
f3ConnectGuardFlowStatsRxOverrunPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of packets discarded because the number of
 | 
						|
         received packets exceeded the cryptographic performance
 | 
						|
         capabilities."
 | 
						|
     ::= { f3ConnectGuardFlowStatsEntry 12 }
 | 
						|
 | 
						|
--
 | 
						|
-- Mac Sec Flow History Statistics Table
 | 
						|
--
 | 
						|
f3ConnectGuardFlowHistoryTable OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF F3ConnectGuardFlowHistoryEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A collection of Connect Guard Flow history statistics.  
 | 
						|
             These reflect the history data."
 | 
						|
    ::= { f3ConnectGuardPerformanceObjects 2 }
 | 
						|
 | 
						|
f3ConnectGuardFlowHistoryEntry OBJECT-TYPE
 | 
						|
    SYNTAX      F3ConnectGuardFlowHistoryEntry 
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A conceptual row in the f3ConnectGuardFlowHistoryTable.
 | 
						|
             Entries exist in this table for each Connect Guard Flow."
 | 
						|
    INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardFlowStatsIndex, f3ConnectGuardFlowHistoryIndex }
 | 
						|
    ::= { f3ConnectGuardFlowHistoryTable 1 }
 | 
						|
 | 
						|
F3ConnectGuardFlowHistoryEntry ::= SEQUENCE {
 | 
						|
    f3ConnectGuardFlowHistoryIndex                     Integer32,
 | 
						|
    f3ConnectGuardFlowHistoryTime                      DateAndTime,
 | 
						|
    f3ConnectGuardFlowHistoryValid                     TruthValue,
 | 
						|
    f3ConnectGuardFlowHistoryAction                    CmPmBinAction,
 | 
						|
    f3ConnectGuardFlowHistoryTxUntaggedPkts            PerfCounter64,
 | 
						|
    f3ConnectGuardFlowHistoryTxTooLongPkts             PerfCounter64,
 | 
						|
    f3ConnectGuardFlowHistoryRxUntaggedPkts            PerfCounter64,
 | 
						|
    f3ConnectGuardFlowHistoryRxNotagPkts               PerfCounter64,
 | 
						|
    f3ConnectGuardFlowHistoryRxBadtagPkts              PerfCounter64,
 | 
						|
    f3ConnectGuardFlowHistoryRxUnknownSCIPkts          PerfCounter64,
 | 
						|
    f3ConnectGuardFlowHistoryRxNoSCIPkts               PerfCounter64,
 | 
						|
    f3ConnectGuardFlowHistoryRxOverrunPkts             PerfCounter64
 | 
						|
}
 | 
						|
 | 
						|
f3ConnectGuardFlowHistoryIndex OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32
 | 
						|
    MAX-ACCESS  not-accessible 
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "An arbitrary integer index value used to uniquely identify
 | 
						|
            this Connect Guard Flow statistics entry."
 | 
						|
    ::= { f3ConnectGuardFlowHistoryEntry 1 }
 | 
						|
 | 
						|
f3ConnectGuardFlowHistoryTime OBJECT-TYPE
 | 
						|
    SYNTAX      DateAndTime
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Indicates the time of history bin creation."
 | 
						|
    ::= { f3ConnectGuardFlowHistoryEntry 2 }
 | 
						|
 | 
						|
f3ConnectGuardFlowHistoryValid OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Indicates the validity of the bin."
 | 
						|
    ::= { f3ConnectGuardFlowHistoryEntry 3 }
 | 
						|
 | 
						|
f3ConnectGuardFlowHistoryAction OBJECT-TYPE
 | 
						|
    SYNTAX      CmPmBinAction
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Allows the operator to clear the bin."
 | 
						|
    ::= { f3ConnectGuardFlowHistoryEntry 4 }
 | 
						|
 | 
						|
f3ConnectGuardFlowHistoryTxUntaggedPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of transmitted packets without the MAC	security tag (SecTAG)."
 | 
						|
     ::= { f3ConnectGuardFlowHistoryEntry 5 }
 | 
						|
 | 
						|
f3ConnectGuardFlowHistoryTxTooLongPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of transmitted packets discarded because the packet
 | 
						|
 	        length is greater than the ifMtu of the Common Port interface."
 | 
						|
     ::= { f3ConnectGuardFlowHistoryEntry 6 }
 | 
						|
 | 
						|
f3ConnectGuardFlowHistoryRxUntaggedPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of received packets without the MAC security tag(SecTAG)."
 | 
						|
     ::= { f3ConnectGuardFlowHistoryEntry 7 }
 | 
						|
 | 
						|
f3ConnectGuardFlowHistoryRxNotagPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of received packets discarded without the MAC security tag (SecTAG)."
 | 
						|
     ::= { f3ConnectGuardFlowHistoryEntry 8 }
 | 
						|
 | 
						|
f3ConnectGuardFlowHistoryRxBadtagPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of received packets discarded with an invalid
 | 
						|
 	        SecTAG or a zero value PN or an invalid ICV."
 | 
						|
     ::= { f3ConnectGuardFlowHistoryEntry 9 }
 | 
						|
 | 
						|
f3ConnectGuardFlowHistoryRxUnknownSCIPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of received packets with unknown SCI."
 | 
						|
     ::= { f3ConnectGuardFlowHistoryEntry 10 }
 | 
						|
 | 
						|
f3ConnectGuardFlowHistoryRxNoSCIPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of received packets discarded with unknown SCI information."
 | 
						|
     ::= { f3ConnectGuardFlowHistoryEntry 11 }
 | 
						|
 | 
						|
f3ConnectGuardFlowHistoryRxOverrunPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of packets discarded because the number of
 | 
						|
         received packets exceeded the cryptographic performance
 | 
						|
         capabilities."
 | 
						|
     ::= { f3ConnectGuardFlowHistoryEntry 12 }
 | 
						|
 | 
						|
--
 | 
						|
-- Connect Guard Flow Threshold Table
 | 
						|
--
 | 
						|
f3ConnectGuardFlowThresholdTable OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF F3ConnectGuardFlowThresholdEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A table of entries that allow manageability of Connect Guard Flow
 | 
						|
             Thresholds."
 | 
						|
    ::= { f3ConnectGuardPerformanceObjects 3 }
 | 
						|
 | 
						|
f3ConnectGuardFlowThresholdEntry OBJECT-TYPE
 | 
						|
    SYNTAX      F3ConnectGuardFlowThresholdEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A conceptual row in the f3PtpAccPortFlowPointThresholdTable."
 | 
						|
    INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardFlowStatsIndex, 
 | 
						|
            f3ConnectGuardFlowThresholdIndex }
 | 
						|
    ::= { f3ConnectGuardFlowThresholdTable 1 }
 | 
						|
 | 
						|
F3ConnectGuardFlowThresholdEntry ::= SEQUENCE {
 | 
						|
    f3ConnectGuardFlowThresholdIndex       Integer32,
 | 
						|
    f3ConnectGuardFlowThresholdInterval    CmPmIntervalType,
 | 
						|
    f3ConnectGuardFlowThresholdVariable    VariablePointer,
 | 
						|
    f3ConnectGuardFlowThresholdValueLo     Unsigned32,
 | 
						|
    f3ConnectGuardFlowThresholdValueHi     Unsigned32,
 | 
						|
    f3ConnectGuardFlowThresholdMonValue    PerfCounter64
 | 
						|
}
 | 
						|
 | 
						|
f3ConnectGuardFlowThresholdIndex OBJECT-TYPE
 | 
						|
    SYNTAX     Integer32 (1..65535)
 | 
						|
    MAX-ACCESS not-accessible 
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "An index that uniquely identifies an entry in the
 | 
						|
        f3ConnectGuardFlowThresholdTable."
 | 
						|
    ::= { f3ConnectGuardFlowThresholdEntry 1 }
 | 
						|
 | 
						|
f3ConnectGuardFlowThresholdInterval OBJECT-TYPE
 | 
						|
    SYNTAX     CmPmIntervalType
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "The interval over which monitored value is
 | 
						|
        sampled and compared with the specified threshold."
 | 
						|
    ::= { f3ConnectGuardFlowThresholdEntry 2 }
 | 
						|
 | 
						|
f3ConnectGuardFlowThresholdVariable OBJECT-TYPE
 | 
						|
    SYNTAX     VariablePointer
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "The object identifier of the particular variable to be
 | 
						|
        sampled."
 | 
						|
    ::= { f3ConnectGuardFlowThresholdEntry 3 }
 | 
						|
 | 
						|
f3ConnectGuardFlowThresholdValueLo OBJECT-TYPE
 | 
						|
    SYNTAX     Unsigned32
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "Lower 32 bits of the threshold value."
 | 
						|
    ::= { f3ConnectGuardFlowThresholdEntry 4 }
 | 
						|
 | 
						|
f3ConnectGuardFlowThresholdValueHi OBJECT-TYPE
 | 
						|
    SYNTAX     Unsigned32
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "Higher 32 bits of the threshold value."
 | 
						|
    ::= { f3ConnectGuardFlowThresholdEntry 5 }
 | 
						|
 | 
						|
f3ConnectGuardFlowThresholdMonValue OBJECT-TYPE
 | 
						|
    SYNTAX     PerfCounter64
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "Monitored value corresponding to f3ConnectGuardFlowThresholdVariable."
 | 
						|
    ::= { f3ConnectGuardFlowThresholdEntry 6 }
 | 
						|
 | 
						|
 | 
						|
--
 | 
						|
-- Connect Guard TX SC Current Statistics Table
 | 
						|
--
 | 
						|
f3ConnectGuardTxSCStatsTable OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF F3ConnectGuardTxSCStatsEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A collection of Connect Guard TxSC statistics.  
 | 
						|
             These reflect the current data."
 | 
						|
    ::= { f3ConnectGuardPerformanceObjects 4 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCStatsEntry OBJECT-TYPE
 | 
						|
    SYNTAX      F3ConnectGuardTxSCStatsEntry 
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A conceptual row in the f3ConnectGuardTxSCStatsTable.
 | 
						|
             Entries exist in this table for each Connect Guard TxSC."
 | 
						|
    INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardTxSCIndex, f3ConnectGuardTxSCStatsIndex }
 | 
						|
    ::= { f3ConnectGuardTxSCStatsTable 1 }
 | 
						|
 | 
						|
F3ConnectGuardTxSCStatsEntry ::= SEQUENCE {
 | 
						|
    f3ConnectGuardTxSCStatsIndex                     Integer32,
 | 
						|
    f3ConnectGuardTxSCStatsIntervalType              CmPmIntervalType,
 | 
						|
    f3ConnectGuardTxSCStatsValid                     TruthValue,
 | 
						|
    f3ConnectGuardTxSCStatsAction                    CmPmBinAction,
 | 
						|
    f3ConnectGuardTxSCStatsTxProtectedPkts           PerfCounter64,
 | 
						|
    f3ConnectGuardTxSCStatsTxEncryptedPkts           PerfCounter64,
 | 
						|
    f3ConnectGuardTxSCStatsTxOctetsProtected         PerfCounter64,
 | 
						|
    f3ConnectGuardTxSCStatsTxOctetsEncrypted         PerfCounter64
 | 
						|
}
 | 
						|
 | 
						|
 | 
						|
f3ConnectGuardTxSCStatsIndex OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32 (1..4)
 | 
						|
    MAX-ACCESS  not-accessible 
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "An arbitrary integer index value used to uniquely identify
 | 
						|
            this Connect Guard TX SC statistics entry. 
 | 
						|
            1 - 15min
 | 
						|
            2 - 1day
 | 
						|
            3 - rollover
 | 
						|
            4 - 5min"
 | 
						|
    ::= { f3ConnectGuardTxSCStatsEntry 1 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCStatsIntervalType OBJECT-TYPE
 | 
						|
    SYNTAX      CmPmIntervalType
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Indicates the type of collection, i.e. whether it is
 | 
						|
             15 Min, 1 Day or rollover."
 | 
						|
    ::= { f3ConnectGuardTxSCStatsEntry 2 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCStatsValid OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Indicates the validity of the bin."
 | 
						|
    ::= { f3ConnectGuardTxSCStatsEntry 3 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCStatsAction OBJECT-TYPE
 | 
						|
    SYNTAX      CmPmBinAction
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Allows the operator to clear the bin."
 | 
						|
    ::= { f3ConnectGuardTxSCStatsEntry 4 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCStatsTxProtectedPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of integrity protected but not encrypted packets."
 | 
						|
     ::= { f3ConnectGuardTxSCStatsEntry 5 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCStatsTxEncryptedPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of integrity protected and encrypted packets."
 | 
						|
     ::= { f3ConnectGuardTxSCStatsEntry 6 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCStatsTxOctetsProtected OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of plain text octets that are integrity protected
 | 
						|
        	but not encrypted."
 | 
						|
     ::= { f3ConnectGuardTxSCStatsEntry 7 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCStatsTxOctetsEncrypted OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of plain text octets that are integrity protected
 | 
						|
 	        and encrypted."
 | 
						|
     ::= { f3ConnectGuardTxSCStatsEntry 8 }
 | 
						|
 | 
						|
--
 | 
						|
-- Connect Guard TX SC History Statistics Table
 | 
						|
--
 | 
						|
f3ConnectGuardTxSCHistoryTable OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF F3ConnectGuardTxSCHistoryEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A collection of Connect Guard TxSC history statistics.  
 | 
						|
             These reflect the history data."
 | 
						|
    ::= { f3ConnectGuardPerformanceObjects 5 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCHistoryEntry OBJECT-TYPE
 | 
						|
    SYNTAX      F3ConnectGuardTxSCHistoryEntry 
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A conceptual row in the f3ConnectGuardTxSCHistoryTable.
 | 
						|
             Entries exist in this table for each Connect Guard TX SC."
 | 
						|
    INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardTxSCIndex, f3ConnectGuardTxSCStatsIndex, f3ConnectGuardTxSCHistoryIndex }
 | 
						|
    ::= { f3ConnectGuardTxSCHistoryTable 1 }
 | 
						|
 | 
						|
F3ConnectGuardTxSCHistoryEntry ::= SEQUENCE {
 | 
						|
    f3ConnectGuardTxSCHistoryIndex                     Integer32,
 | 
						|
    f3ConnectGuardTxSCHistoryTime                      DateAndTime,
 | 
						|
    f3ConnectGuardTxSCHistoryValid                     TruthValue,
 | 
						|
    f3ConnectGuardTxSCHistoryAction                    CmPmBinAction,
 | 
						|
    f3ConnectGuardTxSCHistoryTxProtectedPkts           PerfCounter64,
 | 
						|
    f3ConnectGuardTxSCHistoryTxEncryptedPkts           PerfCounter64,
 | 
						|
    f3ConnectGuardTxSCHistoryTxOctetsProtected         PerfCounter64,
 | 
						|
    f3ConnectGuardTxSCHistoryTxOctetsEncrypted         PerfCounter64
 | 
						|
}
 | 
						|
 | 
						|
f3ConnectGuardTxSCHistoryIndex OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32
 | 
						|
    MAX-ACCESS  not-accessible 
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "An arbitrary integer index value used to uniquely identify
 | 
						|
            this Connect Guard TxSC statistics entry."
 | 
						|
    ::= { f3ConnectGuardTxSCHistoryEntry 1 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCHistoryTime OBJECT-TYPE
 | 
						|
    SYNTAX      DateAndTime
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Indicates the time of history bin creation."
 | 
						|
    ::= { f3ConnectGuardTxSCHistoryEntry 2 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCHistoryValid OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Indicates the validity of the bin."
 | 
						|
    ::= { f3ConnectGuardTxSCHistoryEntry 3 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCHistoryAction OBJECT-TYPE
 | 
						|
    SYNTAX      CmPmBinAction
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Allows the operator to clear the bin."
 | 
						|
    ::= { f3ConnectGuardTxSCHistoryEntry 4 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCHistoryTxProtectedPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of integrity protected but not encrypted packets."
 | 
						|
     ::= { f3ConnectGuardTxSCHistoryEntry 5 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCHistoryTxEncryptedPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of integrity protected and encrypted packets."
 | 
						|
     ::= { f3ConnectGuardTxSCHistoryEntry 6 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCHistoryTxOctetsProtected OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of plain text octets that are integrity protected
 | 
						|
        	but not encrypted."
 | 
						|
     ::= { f3ConnectGuardTxSCHistoryEntry 7 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCHistoryTxOctetsEncrypted OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of plain text octets that are integrity protected
 | 
						|
 	        and encrypted."
 | 
						|
     ::= { f3ConnectGuardTxSCHistoryEntry 8 }
 | 
						|
 | 
						|
--
 | 
						|
-- Connect Guard TX SC Threshold Table
 | 
						|
--
 | 
						|
f3ConnectGuardTxSCThresholdTable OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF F3ConnectGuardTxSCThresholdEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A table of entries that allow manageability of Connect Guard TxSC
 | 
						|
             Thresholds."
 | 
						|
    ::= { f3ConnectGuardPerformanceObjects 6 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCThresholdEntry OBJECT-TYPE
 | 
						|
    SYNTAX      F3ConnectGuardTxSCThresholdEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A conceptual row in the f3ConnectGuardTxSCThresholdEntry."
 | 
						|
    INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardTxSCIndex, f3ConnectGuardTxSCStatsIndex, 
 | 
						|
            f3ConnectGuardTxSCThresholdIndex }
 | 
						|
    ::= { f3ConnectGuardTxSCThresholdTable 1 }
 | 
						|
 | 
						|
F3ConnectGuardTxSCThresholdEntry ::= SEQUENCE {
 | 
						|
    f3ConnectGuardTxSCThresholdIndex       Integer32,
 | 
						|
    f3ConnectGuardTxSCThresholdInterval    CmPmIntervalType,
 | 
						|
    f3ConnectGuardTxSCThresholdVariable    VariablePointer,
 | 
						|
    f3ConnectGuardTxSCThresholdValueLo     Unsigned32,
 | 
						|
    f3ConnectGuardTxSCThresholdValueHi     Unsigned32,
 | 
						|
    f3ConnectGuardTxSCThresholdMonValue    PerfCounter64
 | 
						|
}
 | 
						|
 | 
						|
f3ConnectGuardTxSCThresholdIndex OBJECT-TYPE
 | 
						|
    SYNTAX     Integer32 (1..65535)
 | 
						|
    MAX-ACCESS not-accessible 
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "An index that uniquely identifies an entry in the
 | 
						|
        f3ConnectGuardTxSCThresholdTable."
 | 
						|
    ::= { f3ConnectGuardTxSCThresholdEntry 1 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCThresholdInterval OBJECT-TYPE
 | 
						|
    SYNTAX     CmPmIntervalType
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "The interval over which monitored value is
 | 
						|
        sampled and compared with the specified threshold."
 | 
						|
    ::= { f3ConnectGuardTxSCThresholdEntry 2 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCThresholdVariable OBJECT-TYPE
 | 
						|
    SYNTAX     VariablePointer
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "The object identifier of the particular variable to be
 | 
						|
        sampled."
 | 
						|
    ::= { f3ConnectGuardTxSCThresholdEntry 3 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCThresholdValueLo OBJECT-TYPE
 | 
						|
    SYNTAX     Unsigned32
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "Lower 32 bits of the threshold value."
 | 
						|
    ::= { f3ConnectGuardTxSCThresholdEntry 4 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCThresholdValueHi OBJECT-TYPE
 | 
						|
    SYNTAX     Unsigned32
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "Higher 32 bits of the threshold value."
 | 
						|
    ::= { f3ConnectGuardTxSCThresholdEntry 5 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCThresholdMonValue OBJECT-TYPE
 | 
						|
    SYNTAX     PerfCounter64
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "Monitored value corresponding to f3ConnectGuardTxSCThresholdVariable."
 | 
						|
    ::= { f3ConnectGuardTxSCThresholdEntry 6 }
 | 
						|
 | 
						|
--
 | 
						|
-- Connect Guard RX SC Current Statistics Table
 | 
						|
--
 | 
						|
f3ConnectGuardRxSCStatsTable OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF F3ConnectGuardRxSCStatsEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A collection of Connect Guard RxSC statistics.  
 | 
						|
             These reflect the current data."
 | 
						|
    ::= { f3ConnectGuardPerformanceObjects 7 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCStatsEntry OBJECT-TYPE
 | 
						|
    SYNTAX      F3ConnectGuardRxSCStatsEntry 
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A conceptual row in the f3ConnectGuardRxSCStatsTable.
 | 
						|
             Entries exist in this table for each Connect Guard RxSC."
 | 
						|
    INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardRxSCIndex, f3ConnectGuardRxSCStatsIndex }
 | 
						|
    ::= { f3ConnectGuardRxSCStatsTable 1 }
 | 
						|
 | 
						|
F3ConnectGuardRxSCStatsEntry ::= SEQUENCE {
 | 
						|
    f3ConnectGuardRxSCStatsIndex                     Integer32,
 | 
						|
    f3ConnectGuardRxSCStatsIntervalType              CmPmIntervalType,
 | 
						|
    f3ConnectGuardRxSCStatsValid                     TruthValue,
 | 
						|
    f3ConnectGuardRxSCStatsAction                    CmPmBinAction,
 | 
						|
    f3ConnectGuardRxSCStatsRxUnusedSAPkts            PerfCounter64,
 | 
						|
    f3ConnectGuardRxSCStatsRxNoUsingSAPkts           PerfCounter64,
 | 
						|
    f3ConnectGuardRxSCStatsRxLatePkts                PerfCounter64,
 | 
						|
    f3ConnectGuardRxSCStatsRxNotValidPkts            PerfCounter64,
 | 
						|
    f3ConnectGuardRxSCStatsRxInvalidPkts             PerfCounter64,
 | 
						|
    f3ConnectGuardRxSCStatsRxDelayedPkts             PerfCounter64,
 | 
						|
    f3ConnectGuardRxSCStatsRxUncheckedPkts           PerfCounter64,
 | 
						|
    f3ConnectGuardRxSCStatsRxOKPkts                  PerfCounter64,
 | 
						|
    f3ConnectGuardRxSCStatsRxOctetsValidated         PerfCounter64,
 | 
						|
    f3ConnectGuardRxSCStatsRxOctetsDecrypted         PerfCounter64
 | 
						|
}
 | 
						|
 | 
						|
 | 
						|
f3ConnectGuardRxSCStatsIndex OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32 (1..4)
 | 
						|
    MAX-ACCESS  not-accessible 
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "An arbitrary integer index value used to uniquely identify
 | 
						|
            this Connect Guard Rx SC statistics entry. 
 | 
						|
            1 - 15min
 | 
						|
            2 - 1day
 | 
						|
            3 - rollover
 | 
						|
            4 - 5min"
 | 
						|
    ::= { f3ConnectGuardRxSCStatsEntry 1 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCStatsIntervalType OBJECT-TYPE
 | 
						|
    SYNTAX      CmPmIntervalType
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Indicates the type of collection, i.e. whether it is
 | 
						|
             15 Min, 1 Day or rollover."
 | 
						|
    ::= { f3ConnectGuardRxSCStatsEntry 2 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCStatsValid OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Indicates the validity of the bin."
 | 
						|
    ::= { f3ConnectGuardRxSCStatsEntry 3 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCStatsAction OBJECT-TYPE
 | 
						|
    SYNTAX      CmPmBinAction
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Allows the operator to clear the bin."
 | 
						|
    ::= { f3ConnectGuardRxSCStatsEntry 4 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCStatsRxUnusedSAPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The summation of counter secyRxSAStatsUnusedSAPkts
 | 
						|
 	        information for all the SAs."
 | 
						|
     ::= { f3ConnectGuardRxSCStatsEntry 5 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCStatsRxNoUsingSAPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The summation of counter secyRxSAStatsNoUsingSAPkts 
 | 
						|
 	        information for all the SAs."
 | 
						|
     ::= { f3ConnectGuardRxSCStatsEntry 6 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCStatsRxLatePkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "the number of received packets that have
 | 
						|
 	        been discarded with the condition : secyReplayProtect is equal
 | 
						|
 	        to true and the PN of the packet is lower than the lower bound
 | 
						|
 	        replay check PN."
 | 
						|
     ::= { f3ConnectGuardRxSCStatsEntry 7 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCStatsRxNotValidPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The summation of counter secyRxSAStatsNotValidPkts
 | 
						|
 	        information for all the SAs."
 | 
						|
     ::= { f3ConnectGuardRxSCStatsEntry 8 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCStatsRxInvalidPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The summation of counter secyRxSAStatsInvalidPkts
 | 
						|
 	        information for all the SAs."
 | 
						|
     ::= { f3ConnectGuardRxSCStatsEntry 9 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCStatsRxDelayedPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of packets with the condition
 | 
						|
 	        that the PN of the packets is lower than the lower bound
 | 
						|
 	        replay protection PN."
 | 
						|
     ::= { f3ConnectGuardRxSCStatsEntry 10 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCStatsRxUncheckedPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of packets with the following condition:
 | 
						|
 	        -secyValidateFrames is disabled or
 | 
						|
 	        -secyValidateFrames is not disabled and the packet is not
 | 
						|
 	           encrypted and the integrity check has failed or
 | 
						|
 	        -secyValidateFrames is not disable and the packet is
 | 
						|
 	           encrypted and integrity check has failed."
 | 
						|
     ::= { f3ConnectGuardRxSCStatsEntry 11 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCStatsRxOKPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The summation of counter secyRxSAStatsOKPkts
 | 
						|
         information for all the SAs."
 | 
						|
     ::= { f3ConnectGuardRxSCStatsEntry 12 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCStatsRxOctetsValidated OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of octets of plaintext recovered from received
 | 
						|
         	packets that were integrity protected but not encrypted."
 | 
						|
     ::= { f3ConnectGuardRxSCStatsEntry 13 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCStatsRxOctetsDecrypted OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of octets of plaintext recovered from received
 | 
						|
 	        packets that were integrity protected and encrypted."
 | 
						|
     ::= { f3ConnectGuardRxSCStatsEntry 14 }
 | 
						|
 | 
						|
 | 
						|
--
 | 
						|
-- Connect Guard RX SC History Statistics Table
 | 
						|
--
 | 
						|
f3ConnectGuardRxSCHistoryTable OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF F3ConnectGuardRxSCHistoryEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A collection of Connect Guard RxSC history statistics.  
 | 
						|
             These reflect the history data."
 | 
						|
    ::= { f3ConnectGuardPerformanceObjects 8 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCHistoryEntry OBJECT-TYPE
 | 
						|
    SYNTAX      F3ConnectGuardRxSCHistoryEntry 
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A conceptual row in the f3ConnectGuardRxSCHistoryTable.
 | 
						|
             Entries exist in this table for each Connect Guard Flow RX SC."
 | 
						|
    INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardRxSCIndex, f3ConnectGuardRxSCStatsIndex, f3ConnectGuardRxSCHistoryIndex }
 | 
						|
    ::= { f3ConnectGuardRxSCHistoryTable 1 }
 | 
						|
 | 
						|
F3ConnectGuardRxSCHistoryEntry ::= SEQUENCE {
 | 
						|
    f3ConnectGuardRxSCHistoryIndex                     Integer32,
 | 
						|
    f3ConnectGuardRxSCHistoryTime                      DateAndTime,
 | 
						|
    f3ConnectGuardRxSCHistoryValid                     TruthValue,
 | 
						|
    f3ConnectGuardRxSCHistoryAction                    CmPmBinAction,
 | 
						|
    f3ConnectGuardRxSCHistoryRxUnusedSAPkts            PerfCounter64,
 | 
						|
    f3ConnectGuardRxSCHistoryRxNoUsingSAPkts           PerfCounter64,
 | 
						|
    f3ConnectGuardRxSCHistoryRxLatePkts                PerfCounter64,
 | 
						|
    f3ConnectGuardRxSCHistoryRxNotValidPkts            PerfCounter64,
 | 
						|
    f3ConnectGuardRxSCHistoryRxInvalidPkts             PerfCounter64,
 | 
						|
    f3ConnectGuardRxSCHistoryRxDelayedPkts             PerfCounter64,
 | 
						|
    f3ConnectGuardRxSCHistoryRxUncheckedPkts           PerfCounter64,
 | 
						|
    f3ConnectGuardRxSCHistoryRxOKPkts                  PerfCounter64,
 | 
						|
    f3ConnectGuardRxSCHistoryRxOctetsValidated         PerfCounter64,
 | 
						|
    f3ConnectGuardRxSCHistoryRxOctetsDecrypted         PerfCounter64
 | 
						|
}
 | 
						|
 | 
						|
f3ConnectGuardRxSCHistoryIndex OBJECT-TYPE
 | 
						|
    SYNTAX      Integer32
 | 
						|
    MAX-ACCESS  not-accessible 
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "An arbitrary integer index value used to uniquely identify
 | 
						|
            this Connect Guard RxSC statistics entry."
 | 
						|
    ::= { f3ConnectGuardRxSCHistoryEntry 1 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCHistoryTime OBJECT-TYPE
 | 
						|
    SYNTAX      DateAndTime
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Indicates the time of history bin creation."
 | 
						|
    ::= { f3ConnectGuardRxSCHistoryEntry 2 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCHistoryValid OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Indicates the validity of the bin."
 | 
						|
    ::= { f3ConnectGuardRxSCHistoryEntry 3 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCHistoryAction OBJECT-TYPE
 | 
						|
    SYNTAX      CmPmBinAction
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Allows the operator to clear the bin."
 | 
						|
    ::= { f3ConnectGuardRxSCHistoryEntry 4 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCHistoryRxUnusedSAPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The summation of counter secyRxSAStatsUnusedSAPkts
 | 
						|
 	        information for all the SAs."
 | 
						|
     ::= { f3ConnectGuardRxSCHistoryEntry 5 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCHistoryRxNoUsingSAPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The summation of counter secyRxSAStatsNoUsingSAPkts 
 | 
						|
 	        information for all the SAs."
 | 
						|
     ::= { f3ConnectGuardRxSCHistoryEntry 6 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCHistoryRxLatePkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "the number of received packets that have
 | 
						|
 	        been discarded with the condition : secyReplayProtect is equal
 | 
						|
 	        to true and the PN of the packet is lower than the lower bound
 | 
						|
 	        replay check PN."
 | 
						|
     ::= { f3ConnectGuardRxSCHistoryEntry 7 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCHistoryRxNotValidPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The summation of counter secyRxSAStatsNotValidPkts
 | 
						|
 	        information for all the SAs."
 | 
						|
     ::= { f3ConnectGuardRxSCHistoryEntry 8 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCHistoryRxInvalidPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The summation of counter secyRxSAStatsInvalidPkts
 | 
						|
 	        information for all the SAs."
 | 
						|
     ::= { f3ConnectGuardRxSCHistoryEntry 9 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCHistoryRxDelayedPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of packets with the condition
 | 
						|
 	        that the PN of the packets is lower than the lower bound
 | 
						|
 	        replay protection PN."
 | 
						|
     ::= { f3ConnectGuardRxSCHistoryEntry 10 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCHistoryRxUncheckedPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of packets with the following condition:
 | 
						|
 	        -secyValidateFrames is disabled or
 | 
						|
 	        -secyValidateFrames is not disabled and the packet is not
 | 
						|
 	           encrypted and the integrity check has failed or
 | 
						|
 	        -secyValidateFrames is not disable and the packet is
 | 
						|
 	           encrypted and integrity check has failed."
 | 
						|
     ::= { f3ConnectGuardRxSCHistoryEntry 11 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCHistoryRxOKPkts OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The summation of counter secyRxSAStatsOKPkts
 | 
						|
         information for all the SAs."
 | 
						|
     ::= { f3ConnectGuardRxSCHistoryEntry 12 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCHistoryRxOctetsValidated OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of octets of plaintext recovered from received
 | 
						|
         	packets that were integrity protected but not encrypted."
 | 
						|
     ::= { f3ConnectGuardRxSCHistoryEntry 13 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCHistoryRxOctetsDecrypted OBJECT-TYPE
 | 
						|
     SYNTAX     PerfCounter64
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of octets of plaintext recovered from received
 | 
						|
 	        packets that were integrity protected and encrypted."
 | 
						|
     ::= { f3ConnectGuardRxSCHistoryEntry 14 }
 | 
						|
 | 
						|
--
 | 
						|
-- Connect Guard RX SC Threshold Table
 | 
						|
--
 | 
						|
f3ConnectGuardRxSCThresholdTable OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF F3ConnectGuardRxSCThresholdEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A table of entries that allow manageability of Connect Guard RxSC
 | 
						|
             Thresholds."
 | 
						|
    ::= { f3ConnectGuardPerformanceObjects 9 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCThresholdEntry OBJECT-TYPE
 | 
						|
    SYNTAX      F3ConnectGuardRxSCThresholdEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A conceptual row in the f3ConnectGuardRxSCThresholdEntry."
 | 
						|
    INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardRxSCIndex, f3ConnectGuardRxSCStatsIndex, 
 | 
						|
            f3ConnectGuardRxSCThresholdIndex }
 | 
						|
    ::= { f3ConnectGuardRxSCThresholdTable 1 }
 | 
						|
 | 
						|
F3ConnectGuardRxSCThresholdEntry ::= SEQUENCE {
 | 
						|
    f3ConnectGuardRxSCThresholdIndex       Integer32,
 | 
						|
    f3ConnectGuardRxSCThresholdInterval    CmPmIntervalType,
 | 
						|
    f3ConnectGuardRxSCThresholdVariable    VariablePointer,
 | 
						|
    f3ConnectGuardRxSCThresholdValueLo     Unsigned32,
 | 
						|
    f3ConnectGuardRxSCThresholdValueHi     Unsigned32,
 | 
						|
    f3ConnectGuardRxSCThresholdMonValue    PerfCounter64
 | 
						|
}
 | 
						|
 | 
						|
f3ConnectGuardRxSCThresholdIndex OBJECT-TYPE
 | 
						|
    SYNTAX     Integer32 (1..65535)
 | 
						|
    MAX-ACCESS not-accessible 
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "An index that uniquely identifies an entry in the
 | 
						|
         f3ConnectGuardRxSCThresholdTable."
 | 
						|
    ::= { f3ConnectGuardRxSCThresholdEntry 1 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCThresholdInterval OBJECT-TYPE
 | 
						|
    SYNTAX     CmPmIntervalType
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "The interval over which monitored value is
 | 
						|
         sampled and compared with the specified threshold."
 | 
						|
    ::= { f3ConnectGuardRxSCThresholdEntry 2 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCThresholdVariable OBJECT-TYPE
 | 
						|
    SYNTAX     VariablePointer
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "The object identifier of the particular variable to be
 | 
						|
         sampled."
 | 
						|
    ::= { f3ConnectGuardRxSCThresholdEntry 3 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCThresholdValueLo OBJECT-TYPE
 | 
						|
    SYNTAX     Unsigned32
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "Lower 32 bits of the threshold value."
 | 
						|
    ::= { f3ConnectGuardRxSCThresholdEntry 4 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCThresholdValueHi OBJECT-TYPE
 | 
						|
    SYNTAX     Unsigned32
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "Higher 32 bits of the threshold value."
 | 
						|
    ::= { f3ConnectGuardRxSCThresholdEntry 5 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCThresholdMonValue OBJECT-TYPE
 | 
						|
    SYNTAX     PerfCounter64
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
        "Monitored value corresponding to f3ConnectGuardRxSCThresholdVariable."
 | 
						|
    ::= { f3ConnectGuardRxSCThresholdEntry 6 }
 | 
						|
 | 
						|
--
 | 
						|
-- Connect Guard Tx SA Statistics Table
 | 
						|
--
 | 
						|
f3ConnectGuardTxSAStatsTable OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF F3ConnectGuardTxSAStatsEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A collection of Connect Guard Tx SA statistics.  
 | 
						|
             These reflect the current data."
 | 
						|
    ::= { f3ConnectGuardPerformanceObjects 10 }
 | 
						|
 | 
						|
f3ConnectGuardTxSAStatsEntry OBJECT-TYPE
 | 
						|
    SYNTAX      F3ConnectGuardTxSAStatsEntry 
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A conceptual row in the f3ConnectGuardTxSAStatsTable.
 | 
						|
             Entries exist in this table for each Connect Guard TxSA."
 | 
						|
    INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardTxSCIndex,f3ConnectGuardTxSAIndex }
 | 
						|
    ::= { f3ConnectGuardTxSAStatsTable 1 }
 | 
						|
 | 
						|
F3ConnectGuardTxSAStatsEntry ::= SEQUENCE {
 | 
						|
    f3ConnectGuardTxSAStatsProtectedPkts         PerfCounter64,
 | 
						|
    f3ConnectGuardTxSAStatsEncryptedPkts         PerfCounter64
 | 
						|
}
 | 
						|
 | 
						|
f3ConnectGuardTxSAStatsProtectedPkts OBJECT-TYPE
 | 
						|
    SYNTAX      PerfCounter64
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "The number of integrity protected but not encrypted packets
 | 
						|
 	           for this transmitting SA."
 | 
						|
    ::= { f3ConnectGuardTxSAStatsEntry 1 }
 | 
						|
 | 
						|
f3ConnectGuardTxSAStatsEncryptedPkts OBJECT-TYPE
 | 
						|
    SYNTAX      PerfCounter64
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "The number of integrity protected and encrypted packets for
 | 
						|
 	           this transmitting SA."
 | 
						|
    ::= { f3ConnectGuardTxSAStatsEntry 2 }
 | 
						|
 | 
						|
--
 | 
						|
-- Connect Guard Rx SA Statistics Table
 | 
						|
--
 | 
						|
f3ConnectGuardRxSAStatsTable OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF F3ConnectGuardRxSAStatsEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A collection of Connect Guard Rx SA statistics.  
 | 
						|
             These reflect the current data."
 | 
						|
    ::= { f3ConnectGuardPerformanceObjects 11 }
 | 
						|
 | 
						|
f3ConnectGuardRxSAStatsEntry OBJECT-TYPE
 | 
						|
    SYNTAX      F3ConnectGuardRxSAStatsEntry 
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "A conceptual row in the f3ConnectGuardRxSAStatsTable.
 | 
						|
             Entries exist in this table for each Connect Guard RxSA."
 | 
						|
    INDEX { neIndex, f3ConnectGuardFlowIndex, f3ConnectGuardRxSCIndex ,f3ConnectGuardRxSAIndex }
 | 
						|
    ::= { f3ConnectGuardRxSAStatsTable 1 }
 | 
						|
 | 
						|
F3ConnectGuardRxSAStatsEntry ::= SEQUENCE {
 | 
						|
    f3ConnectGuardRxSAStatsUnusedSAPkts          PerfCounter64,
 | 
						|
    f3ConnectGuardRxSAStatsNoUsingSAPkts         PerfCounter64,
 | 
						|
    f3ConnectGuardRxSAStatsNotValidPkts          PerfCounter64,
 | 
						|
    f3ConnectGuardRxSAStatsInvalidPkts           PerfCounter64,
 | 
						|
    f3ConnectGuardRxSAStatsOKPkts                PerfCounter64
 | 
						|
}
 | 
						|
 | 
						|
f3ConnectGuardRxSAStatsUnusedSAPkts OBJECT-TYPE
 | 
						|
    SYNTAX      PerfCounter64
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "For this SA which is not currently in use, the number of
 | 
						|
            received, unencrypted, packets with secyValidateFrames
 | 
						|
            not in the strict mode."
 | 
						|
    ::= { f3ConnectGuardRxSAStatsEntry 1 }
 | 
						|
 | 
						|
f3ConnectGuardRxSAStatsNoUsingSAPkts OBJECT-TYPE
 | 
						|
    SYNTAX      PerfCounter64
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "For this SA which is not currently in use, the number of
 | 
						|
            received packets that have been discarded, and have
 | 
						|
            either the packets encrypted or the secyValidateFrames set to
 | 
						|
            strict mode."
 | 
						|
    ::= { f3ConnectGuardRxSAStatsEntry 2 }
 | 
						|
 | 
						|
f3ConnectGuardRxSAStatsNotValidPkts OBJECT-TYPE
 | 
						|
    SYNTAX      PerfCounter64
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "For this SA, the number discarded packets with the
 | 
						|
            condition that the packets are not valid and one of the
 | 
						|
            following conditions are true: either secyValidateFrames in
 | 
						|
            strict mode or the packets encrypted."
 | 
						|
    ::= { f3ConnectGuardRxSAStatsEntry 3 }
 | 
						|
 | 
						|
f3ConnectGuardRxSAStatsInvalidPkts OBJECT-TYPE
 | 
						|
    SYNTAX      PerfCounter64
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "For this SA, the number of packets with the condition
 | 
						|
            that the packets are not valid and secyValidateFrames is in
 | 
						|
            check mode."
 | 
						|
    ::= { f3ConnectGuardRxSAStatsEntry 4 }
 | 
						|
 | 
						|
f3ConnectGuardRxSAStatsOKPkts OBJECT-TYPE
 | 
						|
    SYNTAX      PerfCounter64
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "For this SA, the number of validated packets."
 | 
						|
    ::= { f3ConnectGuardRxSAStatsEntry 5 }
 | 
						|
 | 
						|
---
 | 
						|
---Notifications
 | 
						|
---
 | 
						|
f3ConnectGuardFlowThresholdCrossingAlert NOTIFICATION-TYPE
 | 
						|
    OBJECTS {
 | 
						|
                f3ConnectGuardFlowThresholdIndex,       
 | 
						|
                f3ConnectGuardFlowThresholdInterval,
 | 
						|
                f3ConnectGuardFlowThresholdVariable,
 | 
						|
                f3ConnectGuardFlowThresholdValueLo,
 | 
						|
                f3ConnectGuardFlowThresholdValueHi,
 | 
						|
                f3ConnectGuardFlowThresholdMonValue
 | 
						|
            }
 | 
						|
    STATUS  current
 | 
						|
    DESCRIPTION
 | 
						|
            "This trap is sent each time a threshold on a PM condition
 | 
						|
             on an Connect Guard flow is crossed."
 | 
						|
  ::= { f3ConnectGuardNotifications 1 }
 | 
						|
 | 
						|
f3ConnectGuardTxSCThresholdCrossingAlert NOTIFICATION-TYPE
 | 
						|
    OBJECTS {
 | 
						|
                f3ConnectGuardTxSCThresholdIndex,       
 | 
						|
                f3ConnectGuardTxSCThresholdInterval,
 | 
						|
                f3ConnectGuardTxSCThresholdVariable,
 | 
						|
                f3ConnectGuardTxSCThresholdValueLo,
 | 
						|
                f3ConnectGuardTxSCThresholdValueHi,
 | 
						|
                f3ConnectGuardTxSCThresholdMonValue
 | 
						|
            }
 | 
						|
    STATUS  current
 | 
						|
    DESCRIPTION
 | 
						|
            "This trap is sent each time a threshold on a PM condition
 | 
						|
             on an Connect Guard Tx SC is crossed."
 | 
						|
  ::= { f3ConnectGuardNotifications 2 }
 | 
						|
 | 
						|
f3ConnectGuardRxSCThresholdCrossingAlert NOTIFICATION-TYPE
 | 
						|
    OBJECTS {
 | 
						|
                f3ConnectGuardRxSCThresholdIndex,       
 | 
						|
                f3ConnectGuardRxSCThresholdInterval,
 | 
						|
                f3ConnectGuardRxSCThresholdVariable,
 | 
						|
                f3ConnectGuardRxSCThresholdValueLo,
 | 
						|
                f3ConnectGuardRxSCThresholdValueHi,
 | 
						|
                f3ConnectGuardRxSCThresholdMonValue
 | 
						|
            }
 | 
						|
    STATUS  current
 | 
						|
    DESCRIPTION
 | 
						|
            "This trap is sent each time a threshold on a PM condition
 | 
						|
             on an Connect Guard Rx SC is crossed."
 | 
						|
  ::= { f3ConnectGuardNotifications 3 }
 | 
						|
 | 
						|
f3ConnectGuardStateChangeTrap NOTIFICATION-TYPE
 | 
						|
    OBJECTS {
 | 
						|
                f3FlowSecureState
 | 
						|
            }
 | 
						|
    STATUS  current
 | 
						|
    DESCRIPTION
 | 
						|
            "This trap is sent each time secure state value changed."
 | 
						|
  ::= { f3ConnectGuardNotifications 4 }
 | 
						|
 | 
						|
--
 | 
						|
-- Conformance
 | 
						|
--
 | 
						|
f3ConnectGuardCompliances OBJECT IDENTIFIER ::= {f3ConnectGuardConformance 1}
 | 
						|
f3ConnectGuardGroups      OBJECT IDENTIFIER ::= {f3ConnectGuardConformance 2}
 | 
						|
 | 
						|
f3ConnectGuardCompliance MODULE-COMPLIANCE
 | 
						|
    STATUS  current
 | 
						|
    DESCRIPTION
 | 
						|
            "Describes the requirements for conformance to the Connect Guard."
 | 
						|
    MODULE  -- this module
 | 
						|
        MANDATORY-GROUPS {
 | 
						|
              f3ConnectGuardObjectsGroup, f3ConnectGuardPerfGroup
 | 
						|
        }
 | 
						|
    ::= { f3ConnectGuardCompliances 1 }
 | 
						|
 | 
						|
f3ConnectGuardObjectsGroup OBJECT-GROUP
 | 
						|
    OBJECTS {
 | 
						|
        f3ConnectGuardFlowIndex,f3ConnectGuardFlowEgressInterface,
 | 
						|
        f3ConnectGuardFlowAdminState,f3ConnectGuardFlowSecondaryState,
 | 
						|
        f3ConnectGuardFlowOperationalState,f3ConnectGuardFlowCipherSuite,
 | 
						|
        f3ConnectGuardFlowKeyExchangeProfile,f3ConnectGuardFlowKeyExchangeFrameTagControl,
 | 
						|
        f3ConnectGuardFlowKeyExchangeFrameOuterVlanEnabled,
 | 
						|
        f3ConnectGuardFlowKeyExchangeFrameOuterVlanId,
 | 
						|
        f3ConnectGuardFlowKeyExchangeFrameOuterVlanPriority,
 | 
						|
        f3ConnectGuardFlowKeyExchangeFrameInner1VlanEnabled,
 | 
						|
        f3ConnectGuardFlowKeyExchangeFrameInner1VlanId,
 | 
						|
        f3ConnectGuardFlowKeyExchangeFrameInner1VlanPriority,
 | 
						|
        f3ConnectGuardFlowKeyExchangeFrameInner2VlanEnabled,
 | 
						|
        f3ConnectGuardFlowKeyExchangeFrameInner2VlanId,
 | 
						|
        f3ConnectGuardFlowKeyExchangeFrameInner2VlanPriority,
 | 
						|
        f3ConnectGuardFlowKeyExchangeInterval,f3ConnectGuardFlowTagsClear,
 | 
						|
        f3ConnectGuardFlowStorageType,f3ConnectGuardFlowRowStatus,
 | 
						|
        f3ConnectGuardFlowKeyXchgFailsCounts,f3ConnectGuardFlowAction,
 | 
						|
        f3ConnectGuardFlowReplayProtectionEnabled,
 | 
						|
        f3ConnectGuardFlowReplayProtectionWindow,f3ConnectGuardFlowRemoteMacAddrEnabled,
 | 
						|
        f3ConnectGuardFlowRemoteMacAddr, f3ConnectGuardFlowAssociatedMep,
 | 
						|
        f3ConnectGuardFlowAlias,
 | 
						|
        f3ConnectGuardFlowKeyExchangeFrameOuterVlanEtherType,
 | 
						|
        f3ConnectGuardFlowKeyExchangeFrameInner1VlanEtherType,
 | 
						|
        f3ConnectGuardFlowKeyExchangeFrameInner2VlanEtherType,
 | 
						|
        f3ConnectGuardFlowKeyInjectFlowPoint,
 | 
						|
 | 
						|
        f3ConnectGuardKeyExchangeProfileIndex,
 | 
						|
        f3ConnectGuardKeyExchangeProfileName,
 | 
						|
        f3ConnectGuardKeyExchangeProfileUserId,
 | 
						|
        f3ConnectGuardKeyExchangeProfileMode,
 | 
						|
        f3ConnectGuardKeyExchangeProfileAuthPassword,
 | 
						|
        f3ConnectGuardKeyExchangeProfileDiffieHellmanKeyPairLen,
 | 
						|
        f3ConnectGuardKeyExchangeProfileStorageType,
 | 
						|
        f3ConnectGuardKeyExchangeProfileRowStatus,
 | 
						|
 | 
						|
        f3ConnectGuardTxSCIndex,
 | 
						|
        f3ConnectGuardTxSCI,
 | 
						|
        f3ConnectGuardTxScState,
 | 
						|
        f3ConnectGuardCurrentTxSa,
 | 
						|
        f3ConnectGuardPreviousTxSa,
 | 
						|
        f3ConnectGuardTxScCreateTime,
 | 
						|
        f3ConnectGuardTxScStartTime,
 | 
						|
        f3ConnectGuardTxScStopTime,
 | 
						|
 | 
						|
        f3ConnectGuardRxSCIndex,
 | 
						|
        f3ConnectGuardRxSCI,
 | 
						|
        f3ConnectGuardRxScState,
 | 
						|
        f3ConnectGuardCurrentRxSa,
 | 
						|
        f3ConnectGuardRxScCreateTime,
 | 
						|
        f3ConnectGuardRxScStartTime,
 | 
						|
        f3ConnectGuardRxScStopTime,
 | 
						|
 | 
						|
        f3ConnectGuardTxSAIndex,
 | 
						|
        f3ConnectGuardTxSAState,
 | 
						|
        f3ConnectGuardTxSANextPN,
 | 
						|
        f3ConnectGuardTxSASAKUnchanged,
 | 
						|
        f3ConnectGuardTxSACreatedTime,
 | 
						|
        f3ConnectGuardTxSAStartedTime,
 | 
						|
        f3ConnectGuardTxSAStoppedTime,
 | 
						|
 | 
						|
        f3ConnectGuardRxSAIndex,
 | 
						|
        f3ConnectGuardRxSAState,
 | 
						|
        f3ConnectGuardRxSANextPN,
 | 
						|
        f3ConnectGuardRxSASAKUnchanged,
 | 
						|
        f3ConnectGuardRxSACreatedTime,
 | 
						|
        f3ConnectGuardRxSAStartedTime,
 | 
						|
        f3ConnectGuardRxSAStoppedTime,        
 | 
						|
        f3ConnectGuardCryptoPassword, f3ConnectGuardRestoreFactoryApproved,f3ConnectGuardSoftwareVersionApproved,
 | 
						|
        f3ConnectGuardSoftwareInstallApproved,f3ConnectGuardRestoreDatabaseApproved,f3ConnectGuardConfigFileLoadApproved        
 | 
						|
    }
 | 
						|
    STATUS  current
 | 
						|
    DESCRIPTION
 | 
						|
            "A collection of objects used to manage the Connect Guard functionality."
 | 
						|
    ::= { f3ConnectGuardGroups 1 }
 | 
						|
 | 
						|
 | 
						|
 | 
						|
f3ConnectGuardPerfGroup OBJECT-GROUP
 | 
						|
    OBJECTS {
 | 
						|
        f3ConnectGuardFlowStatsIndex,f3ConnectGuardFlowStatsIntervalType,
 | 
						|
        f3ConnectGuardFlowStatsValid,f3ConnectGuardFlowStatsAction,
 | 
						|
        f3ConnectGuardFlowStatsTxUntaggedPkts,f3ConnectGuardFlowStatsTxTooLongPkts,
 | 
						|
        f3ConnectGuardFlowStatsRxUntaggedPkts,f3ConnectGuardFlowStatsRxNotagPkts,
 | 
						|
        f3ConnectGuardFlowStatsRxBadtagPkts,f3ConnectGuardFlowStatsRxUnknownSCIPkts,
 | 
						|
        f3ConnectGuardFlowStatsRxNoSCIPkts,f3ConnectGuardFlowStatsRxOverrunPkts,
 | 
						|
 | 
						|
        
 | 
						|
        f3ConnectGuardFlowHistoryIndex,f3ConnectGuardFlowHistoryTime,
 | 
						|
        f3ConnectGuardFlowHistoryValid,f3ConnectGuardFlowHistoryAction,
 | 
						|
        f3ConnectGuardFlowHistoryTxUntaggedPkts,f3ConnectGuardFlowHistoryTxTooLongPkts,
 | 
						|
        f3ConnectGuardFlowHistoryRxUntaggedPkts,f3ConnectGuardFlowHistoryRxNotagPkts,
 | 
						|
        f3ConnectGuardFlowHistoryRxBadtagPkts,f3ConnectGuardFlowHistoryRxUnknownSCIPkts,
 | 
						|
        f3ConnectGuardFlowHistoryRxNoSCIPkts,f3ConnectGuardFlowHistoryRxOverrunPkts,
 | 
						|
 | 
						|
        f3ConnectGuardFlowThresholdIndex,f3ConnectGuardFlowThresholdInterval,
 | 
						|
        f3ConnectGuardFlowThresholdVariable,f3ConnectGuardFlowThresholdValueLo,
 | 
						|
        f3ConnectGuardFlowThresholdValueHi,f3ConnectGuardFlowThresholdMonValue,
 | 
						|
 | 
						|
        f3ConnectGuardTxSCStatsIndex,f3ConnectGuardTxSCStatsIntervalType,
 | 
						|
        f3ConnectGuardTxSCStatsValid,f3ConnectGuardTxSCStatsAction,
 | 
						|
        f3ConnectGuardTxSCStatsTxProtectedPkts,f3ConnectGuardTxSCStatsTxEncryptedPkts,
 | 
						|
        f3ConnectGuardTxSCStatsTxOctetsProtected,f3ConnectGuardTxSCStatsTxOctetsEncrypted,
 | 
						|
 | 
						|
        f3ConnectGuardTxSCHistoryIndex,f3ConnectGuardTxSCHistoryTime,
 | 
						|
        f3ConnectGuardTxSCHistoryValid,f3ConnectGuardTxSCHistoryAction,
 | 
						|
        f3ConnectGuardTxSCHistoryTxProtectedPkts,f3ConnectGuardTxSCHistoryTxEncryptedPkts,
 | 
						|
        f3ConnectGuardTxSCHistoryTxOctetsProtected,f3ConnectGuardTxSCHistoryTxOctetsEncrypted,
 | 
						|
 | 
						|
        f3ConnectGuardTxSCThresholdIndex,f3ConnectGuardTxSCThresholdInterval,
 | 
						|
        f3ConnectGuardTxSCThresholdVariable,f3ConnectGuardTxSCThresholdValueLo,
 | 
						|
        f3ConnectGuardTxSCThresholdValueHi,f3ConnectGuardTxSCThresholdMonValue,
 | 
						|
 | 
						|
        f3ConnectGuardRxSCStatsIndex,f3ConnectGuardRxSCStatsIntervalType,
 | 
						|
        f3ConnectGuardRxSCStatsValid,f3ConnectGuardRxSCStatsAction,
 | 
						|
        f3ConnectGuardRxSCStatsRxUnusedSAPkts,f3ConnectGuardRxSCStatsRxNoUsingSAPkts,
 | 
						|
        f3ConnectGuardRxSCStatsRxLatePkts,f3ConnectGuardRxSCStatsRxNotValidPkts,
 | 
						|
        f3ConnectGuardRxSCStatsRxInvalidPkts,f3ConnectGuardRxSCStatsRxDelayedPkts,
 | 
						|
        f3ConnectGuardRxSCStatsRxUncheckedPkts,f3ConnectGuardRxSCStatsRxOKPkts,
 | 
						|
        f3ConnectGuardRxSCStatsRxOctetsValidated,f3ConnectGuardRxSCStatsRxOctetsDecrypted,
 | 
						|
 | 
						|
        f3ConnectGuardRxSCHistoryIndex,f3ConnectGuardRxSCHistoryTime,
 | 
						|
        f3ConnectGuardRxSCHistoryValid,f3ConnectGuardRxSCHistoryAction,
 | 
						|
        f3ConnectGuardRxSCHistoryRxUnusedSAPkts,f3ConnectGuardRxSCHistoryRxNoUsingSAPkts,
 | 
						|
        f3ConnectGuardRxSCHistoryRxLatePkts,f3ConnectGuardRxSCHistoryRxNotValidPkts,
 | 
						|
        f3ConnectGuardRxSCHistoryRxInvalidPkts,f3ConnectGuardRxSCHistoryRxDelayedPkts,
 | 
						|
        f3ConnectGuardRxSCHistoryRxUncheckedPkts,f3ConnectGuardRxSCHistoryRxOKPkts,
 | 
						|
        f3ConnectGuardRxSCHistoryRxOctetsValidated,f3ConnectGuardRxSCHistoryRxOctetsDecrypted,
 | 
						|
 | 
						|
        f3ConnectGuardRxSCThresholdIndex,f3ConnectGuardRxSCThresholdInterval,
 | 
						|
        f3ConnectGuardRxSCThresholdVariable,f3ConnectGuardRxSCThresholdValueLo,
 | 
						|
        f3ConnectGuardRxSCThresholdValueHi,f3ConnectGuardRxSCThresholdMonValue,
 | 
						|
 | 
						|
        f3ConnectGuardTxSAStatsProtectedPkts,f3ConnectGuardTxSAStatsEncryptedPkts,
 | 
						|
        
 | 
						|
        f3ConnectGuardRxSAStatsUnusedSAPkts,f3ConnectGuardRxSAStatsNoUsingSAPkts,
 | 
						|
        f3ConnectGuardRxSAStatsNotValidPkts,f3ConnectGuardRxSAStatsInvalidPkts,
 | 
						|
        f3ConnectGuardRxSAStatsOKPkts
 | 
						|
    }
 | 
						|
    STATUS  current
 | 
						|
    DESCRIPTION
 | 
						|
            "A collection of objects performance used to manage the Connect Guard functionality."
 | 
						|
    ::= { f3ConnectGuardGroups 2 }
 | 
						|
END
 |