mibs/MIBS/adva/F3-PBB-MIB

504 lines
19 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
F3-PBB-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
MODULE-IDENTITY, OBJECT-TYPE, Integer32
FROM SNMPv2-SMI
DisplayString, TruthValue, MacAddress, VariablePointer
FROM SNMPv2-TC
cmEthernetAccPortEntry, cmEthernetNetPortEntry, cmFlowEntry,
FlowTagControl
FROM CM-FACILITY-MIB
ipManagementTunnelEntry
FROM CM-IP-MIB
PerfCounter64
FROM CM-COMMON-MIB
cmEthernetNetPortStatsEntry, cmEthernetNetPortHistoryEntry
FROM CM-PERFORMANCE-MIB
fsp150cm
FROM ADVA-MIB;
f3PBBMIB MODULE-IDENTITY
LAST-UPDATED "201210080000Z"
ORGANIZATION "ADVA Optical Networking"
CONTACT-INFO
" Raghav Trivedi
ADVA Optical Networking, Inc.
Tel: +1 972 759-1239
E-mail: rtrivedi@advaoptical.com
Postal: 2301 N. Greenville Ave. #300
Richardson, TX USA 75082"
DESCRIPTION
"This module defines the Facility MIB definitions used by
the F3 (FSP150CM/CC) product lines.
Copyright (C) ADVA Optical Networking."
REVISION "201210080000Z"
DESCRIPTION
"Notes from release 201210080000Z. "
::= {fsp150cm 21}
--
-- OID definitions
--
f3PBBConfigObjects OBJECT IDENTIFIER ::= {f3PBBMIB 1}
f3PBBPerformanceObjects OBJECT IDENTIFIER ::= {f3PBBMIB 2}
f3PBBConformance OBJECT IDENTIFIER ::= {f3PBBMIB 3}
--
-- f3PbbEthernetAccPortTable
--
f3PbbEthernetAccPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3PbbEthernetAccPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of entries corresponding to PBB function on the net port"
::= { f3PBBConfigObjects 1 }
f3PbbEthernetAccPortEntry OBJECT-TYPE
SYNTAX F3PbbEthernetAccPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3PbbEthernetAccPortTable."
AUGMENTS { cmEthernetAccPortEntry }
::= { f3PbbEthernetAccPortTable 1 }
F3PbbEthernetAccPortEntry ::= SEQUENCE {
f3PbbEthernetAccPortITagLoopbackMask INTEGER,
f3PbbEthernetAccPortITagLoopback1 DisplayString,
f3PbbEthernetAccPortITagLoopback2 DisplayString,
f3PbbEthernetAccPortITagLoopback3 DisplayString
}
f3PbbEthernetAccPortITagLoopbackMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows to specify which itag loopback has been enabled.
1: Itag 1 loopback enabled, 2: Itag 2 loopback enabled, 4: Itag 4 loopback enabled."
::= { f3PbbEthernetAccPortEntry 1 }
f3PbbEthernetAccPortITagLoopback1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows specification of the Itag 1 to be looped back when port is in
vlan(terminal/facility) loopback configuration. This is valid only if the
corresponding bit in f3PbbEthernetAccPortITagLoopbackMask is set. The value
to be specified should be in the form X-Y where X is the ISID and Y is the ITAG Priority.
If Y is specified as a *, all Priorities (0 to 7) are looped back."
::= { f3PbbEthernetAccPortEntry 2 }
f3PbbEthernetAccPortITagLoopback2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows specification of the Itag 2 to be looped back when port is in
vlan(terminal/facility) loopback configuration. This is valid only if the
corresponding bit in f3PbbEthernetAccPortITagLoopbackMask is set. The value
to be specified should be in the form X-Y where X is the ISID and Y is the ITAG Priority.
If Y is specified as a *, all Priorities (0 to 7) are looped back."
::= { f3PbbEthernetAccPortEntry 3 }
f3PbbEthernetAccPortITagLoopback3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows specification of the Itag 3 to be looped back when port is in
vlan(terminal/facility) loopback configuration. This is valid only if the
corresponding bit in f3PbbEthernetAccPortITagLoopbackMask is set. The value
to be specified should be in the form X-Y where X is the ISID and Y is the ITAG Priority.
If Y is specified as a *, all Priorities (0 to 7) are looped back."
::= { f3PbbEthernetAccPortEntry 4 }
--
-- f3PbbEthernetNetPortTable
--
f3PbbEthernetNetPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3PbbEthernetNetPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of entries corresponding to PBB function on the net port"
::= { f3PBBConfigObjects 2 }
f3PbbEthernetNetPortEntry OBJECT-TYPE
SYNTAX F3PbbEthernetNetPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3PbbEthernetNetPortTable."
AUGMENTS { cmEthernetNetPortEntry }
::= { f3PbbEthernetNetPortTable 1 }
F3PbbEthernetNetPortEntry ::= SEQUENCE {
f3PbbEthernetNetPortBackboneMacAddress MacAddress,
f3PbbEthernetNetPortITagLoopbackMask INTEGER,
f3PbbEthernetNetPortITagLoopback1 DisplayString,
f3PbbEthernetNetPortITagLoopback2 DisplayString,
f3PbbEthernetNetPortITagLoopback3 DisplayString
}
f3PbbEthernetNetPortBackboneMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is mac address of backbone network port."
::= { f3PbbEthernetNetPortEntry 1 }
f3PbbEthernetNetPortITagLoopbackMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows to specify which itag loopback has been enabled.
1: Itag 1 loopback enabled, 2: Itag 2 loopback enabled, 4: Itag 4 loopback enabled."
::= { f3PbbEthernetNetPortEntry 2 }
f3PbbEthernetNetPortITagLoopback1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows specification of the Itag 1 to be looped back when port is in
vlan(terminal/facility) loopback configuration. This is valid only if the
corresponding bit in f3PbbEthernetNetPortITagLoopbackMask is set. The value
to be specified should be in the form X-Y where X is the ISID and Y is the ITAG Priority.
If Y is specified as a *, all Priorities (0 to 7) are looped back."
::= { f3PbbEthernetNetPortEntry 3 }
f3PbbEthernetNetPortITagLoopback2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows specification of the Itag 2 to be looped back when port is in
vlan(terminal/facility) loopback configuration. This is valid only if the
corresponding bit in f3PbbEthernetNetPortITagLoopbackMask is set. The value
to be specified should be in the form X-Y where X is the ISID and Y is the ITAG Priority.
If Y is specified as a *, all Priorities (0 to 7) are looped back."
::= { f3PbbEthernetNetPortEntry 4 }
f3PbbEthernetNetPortITagLoopback3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows specification of the Itag 3 to be looped back when port is in
vlan(terminal/facility) loopback configuration. This is valid only if the
corresponding bit in f3PbbEthernetNetPortITagLoopbackMask is set. The value
to be specified should be in the form X-Y where X is the ISID and Y is the ITAG Priority.
If Y is specified as a *, all Priorities (0 to 7) are looped back."
::= { f3PbbEthernetNetPortEntry 5 }
--
-- f3PbbFlowTable
--
f3PbbFlowTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3PbbFlowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of entries corresponding to PBB function on the flow"
::= { f3PBBConfigObjects 3 }
f3PbbFlowEntry OBJECT-TYPE
SYNTAX F3PbbFlowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3PbbFlowTable."
AUGMENTS { cmFlowEntry }
::= { f3PbbFlowTable 1 }
F3PbbFlowEntry ::= SEQUENCE {
f3PbbFlowITagControl FlowTagControl,
f3PbbFlowITagISID Integer32,
f3PbbFlowITagPriority Integer32,
f3PbbFlowBackboneMacDestinationEnabled TruthValue,
f3PbbFlowBackboneMacDestinationAddress MacAddress,
f3PbbFlowA2NPbbCapableFlag TruthValue
}
f3PbbFlowITagControl OBJECT-TYPE
SYNTAX FlowTagControl
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows specification of the tag management
operation on the I-TAG. Supported types are 'none', 'push', and 'pushisid'.
and it must be none while ctagcontrol or stagcontrol is not none."
::= { f3PbbFlowEntry 1 }
f3PbbFlowITagISID OBJECT-TYPE
SYNTAX Integer32 (256..16777214)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to specify the ITagISID. Its rang from 256 to 16777214."
::= { f3PbbFlowEntry 2 }
f3PbbFlowITagPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to specify the priority of ITag. Its rang from 0 to 7."
::= { f3PbbFlowEntry 3 }
f3PbbFlowBackboneMacDestinationEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether can assign BMAC value.
When enabled, user can assign a unicast BMAC as B_DA for this EVC
When disabled, 01-1E-83-<I-SID> will be used as B-DA."
::= { f3PbbFlowEntry 4 }
f3PbbFlowBackboneMacDestinationAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Customer can configure the backbone MAC destination address, the
default value is 01-1E-83-<I-SID>."
::= { f3PbbFlowEntry 5 }
f3PbbFlowA2NPbbCapableFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When it is false, Drop PBB frames in the A2N direction (FPGA function),
Allow to PUSH I-TAG on this flow;
When A2NPbbCapableFlag is TRUE,
Pass PBB frames in the A2N direction (FPGA function), Software allow PUSH I-TAG on this flow(normal)
will not allow to PUSH S-TAG on this flow, will not allow to PUSH C-TAG on this flow,
Software will allow to PUSH C-TAG/S-TAG on this flow."
::= { f3PbbFlowEntry 6 }
--
-- f3PbbIpManagementTunnelTable
--
f3PbbIpManagementTunnelTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3PbbIpManagementTunnelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of entries corresponding to PBB function on the mngt tunnel"
::= { f3PBBConfigObjects 4 }
f3PbbIpManagementTunnelEntry OBJECT-TYPE
SYNTAX F3PbbIpManagementTunnelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3PbbIpManagementTunnelTable."
AUGMENTS { ipManagementTunnelEntry }
::= { f3PbbIpManagementTunnelTable 1 }
F3PbbIpManagementTunnelEntry ::= SEQUENCE {
f3PbbIpManagementTunnelItagEnabled TruthValue,
f3PbbIpManagementTunnelISID Integer32,
f3PbbIpManagementTunnelIPriority Integer32,
f3PbbIpManagementTunnelBackboneMacDestinationEnabled TruthValue,
f3PbbIpManagementTunnelBackboneMacDestinationAddress MacAddress
}
f3PbbIpManagementTunnelItagEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object ITAG whether enabled, It is Enabled only When management tunnel type is ISID based.
By default it is disabled"
::= { f3PbbIpManagementTunnelEntry 1 }
f3PbbIpManagementTunnelISID OBJECT-TYPE
SYNTAX Integer32(256..16777214)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Only applicable when iTagEnabled = enabled (ISID is shown to user, but in IFM data type here is ITAG)."
::= { f3PbbIpManagementTunnelEntry 2 }
f3PbbIpManagementTunnelIPriority OBJECT-TYPE
SYNTAX Integer32(0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Only applicable when iTagEnabled = enabled (ISID is shown to user, but in IFM data type here is ITAG, no use at present)."
::= { f3PbbIpManagementTunnelEntry 3 }
f3PbbIpManagementTunnelBackboneMacDestinationEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled, we will use provisioned B-MAC for ARP and for management packets.
When disabled, we will use backbone group MAC address for ARP and get B-DA from ARP response
By default, it is disabled"
::= { f3PbbIpManagementTunnelEntry 4 }
f3PbbIpManagementTunnelBackboneMacDestinationAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User must set a valid MAC address, Only applicable when iTagEnabled = enabled
By default, it is 00:00:00:00:00:00"
::= { f3PbbIpManagementTunnelEntry 5 }
--
-- PBB Net Port Statistics Table
--
f3PbbEthernetNetPortStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3PbbEthernetNetPortStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of pbb Ethernet Network Port related statistics.
These reflect the current data."
::= { f3PBBPerformanceObjects 1 }
f3PbbEthernetNetPortStatsEntry OBJECT-TYPE
SYNTAX F3PbbEthernetNetPortStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3PbbEthernetNetPortStatsTable.
Entries exist in this table for each Ethernet interface/port."
AUGMENTS { cmEthernetNetPortStatsEntry }
::= { f3PbbEthernetNetPortStatsTable 1 }
F3PbbEthernetNetPortStatsEntry ::= SEQUENCE {
f3PbbEthernetNetPortStatsPbbUniBdaDiscard PerfCounter64,
f3PbbEthernetNetPortStatsPbbGroupBdaDiscard PerfCounter64
}
f3PbbEthernetNetPortStatsPbbUniBdaDiscard OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of PBB frames (BDA is not backbone group MAC)
discarded due to receive BDA which is not matching the
port's PBB MAC address when port is non-promiscuous mode."
::= { f3PbbEthernetNetPortStatsEntry 1 }
f3PbbEthernetNetPortStatsPbbGroupBdaDiscard OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of PBB frames discarded due to mismatch of I-SID in I-TAG and I-SID
in backbone group MAC in the B-DA when port is non-promiscuous mode."
::= { f3PbbEthernetNetPortStatsEntry 2 }
--
-- PBB Net Port History Statistics Table
--
f3PbbEthernetNetPortHistoryStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3PbbEthernetNetPortHistoryStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of pbb Ethernet Network Port related statistics.
These reflect the current data."
::= { f3PBBPerformanceObjects 2 }
f3PbbEthernetNetPortHistoryStatsEntry OBJECT-TYPE
SYNTAX F3PbbEthernetNetPortHistoryStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the f3PbbEthernetNetPortHistoryStatsTable.
Entries exist in this table for each Ethernet interface/port."
AUGMENTS { cmEthernetNetPortHistoryEntry }
::= { f3PbbEthernetNetPortHistoryStatsTable 1 }
F3PbbEthernetNetPortHistoryStatsEntry ::= SEQUENCE {
f3PbbEthernetNetPortHistoryStatsPbbUniBdaDiscard PerfCounter64,
f3PbbEthernetNetPortHistoryStatsPbbGroupBdaDiscard PerfCounter64
}
f3PbbEthernetNetPortHistoryStatsPbbUniBdaDiscard OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of PBB frames (BDA is not backbone group MAC)
discarded due to receive BDA which is not matching the
port's PBB MAC address when port is non-promiscuous mode."
::= { f3PbbEthernetNetPortHistoryStatsEntry 1 }
f3PbbEthernetNetPortHistoryStatsPbbGroupBdaDiscard OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of PBB frames discarded due to mismatch of I-SID in I-TAG and I-SID
in backbone group MAC in the B-DA when port is non-promiscuous mode."
::= { f3PbbEthernetNetPortHistoryStatsEntry 2 }
--
--Conformance
--
f3PBBCompliances OBJECT IDENTIFIER ::= {f3PBBConformance 1}
f3PBBGroups OBJECT IDENTIFIER ::= {f3PBBConformance 2}
f3PBBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to the PBB Object
group."
MODULE -- this module
MANDATORY-GROUPS {
f3PbbConfigGroup, f3PbbStatsGroup
}
::= { f3PBBCompliances 1 }
f3PbbConfigGroup OBJECT-GROUP
OBJECTS {
f3PbbEthernetAccPortITagLoopbackMask, f3PbbEthernetAccPortITagLoopback1,
f3PbbEthernetAccPortITagLoopback2, f3PbbEthernetAccPortITagLoopback3,
f3PbbEthernetNetPortBackboneMacAddress, f3PbbEthernetNetPortITagLoopbackMask,
f3PbbEthernetNetPortITagLoopback1, f3PbbEthernetNetPortITagLoopback2,
f3PbbEthernetNetPortITagLoopback3,
f3PbbFlowITagControl, f3PbbFlowITagISID,
f3PbbFlowITagPriority, f3PbbFlowBackboneMacDestinationEnabled,
f3PbbFlowBackboneMacDestinationAddress, f3PbbFlowA2NPbbCapableFlag,
f3PbbIpManagementTunnelItagEnabled, f3PbbIpManagementTunnelISID,
f3PbbIpManagementTunnelIPriority, f3PbbIpManagementTunnelBackboneMacDestinationEnabled,
f3PbbIpManagementTunnelBackboneMacDestinationAddress
}
STATUS current
DESCRIPTION
"A collection of objects used to manage the F3 PBB Functionality
."
::= { f3PBBGroups 1 }
f3PbbStatsGroup OBJECT-GROUP
OBJECTS {
f3PbbEthernetNetPortStatsPbbUniBdaDiscard, f3PbbEthernetNetPortStatsPbbGroupBdaDiscard,
f3PbbEthernetNetPortHistoryStatsPbbUniBdaDiscard, f3PbbEthernetNetPortHistoryStatsPbbGroupBdaDiscard
}
STATUS current
DESCRIPTION
"A collection of objects used to manage the F3 PBB Functionality
."
::= { f3PBBGroups 2 }
END