mibs/MIBS/audiocodes/AC-PMPSTN-MIB

825 lines
24 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
AC-PM-PSTN-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE,
MODULE-IDENTITY FROM SNMPv2-SMI
TAddress,
DisplayString,
DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC
IpAddress FROM RFC1155-SMI
Unsigned32,
Integer32,
enterprises FROM SNMPv2-SMI
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
audioCodes,
acRegistrations,
acGeneric,
acProducts,acBoardMibs,acPerformance FROM AUDIOCODES-TYPES-MIB;
acPMPSTN MODULE-IDENTITY
LAST-UPDATED "200902050516Z" --Thursday, February 05, 2009
ORGANIZATION "AudioCodes Ltd"
CONTACT-INFO
"Postal: Support
AudioCodes LTD
1 Hayarden Street
Airport City
Lod, ISRAEL 70151
Tel: 972-3-9764000
Fax: 972-3-9764040
Email: support@audiocodes.com
Web: www.audiocodes.com"
DESCRIPTION
"The AC-PM-PSTN MIB offers performance monitoring
For the PSTN related elements in Audiocodes' devices.
The Configuration sub-tree is for configuring the interval
Period length for the entire AC-PM-PSTN MIB, and the
different tables' thresholds.
The Data sub-tree presents the tables of monitored
elements.
Note - for the entire MIB the value (-1) means the value
Asked for is either not supported or currently not relevant
(this is for when values asked for are for intervals not yet
recorded."
::= {acPerformance 10}
acPMPSTNConfiguration OBJECT IDENTIFIER ::= {acPMPSTN 1}
acPMPSTNConfigurationPeriodLength OBJECT-TYPE
SYNTAX Unsigned32 (0..894780)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Length of monitoring intervals for entire MIB. Time is in minutes.
Access: Instant."
::= {acPMPSTNConfiguration 1}
acPMPSTNConfigurationResetTotalCounters OBJECT-TYPE
SYNTAX INTEGER {
resetCountersDone(1)
,
resetTotalCounters(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Total-Counters Reset. To reset the total counters, set the
value of this object to resetTotalCounters(2).
Access: Instant."
::= {acPMPSTNConfiguration 2}
acPMTrunkUtilizationAttributes OBJECT IDENTIFIER ::= {acPMPSTNConfiguration 31}
acPMTrunkUtilizationAttributesHighThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High threshold.
Access: Instant."
::= {acPMTrunkUtilizationAttributes 1}
acPMTrunkUtilizationAttributesLowThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low threshold.
Access: Instant."
::= {acPMTrunkUtilizationAttributes 2}
acPMPSTNChannelsAttributes OBJECT IDENTIFIER ::= {acPMPSTNConfiguration 32}
acPMPSTNChannelsAttributesInServiceHighThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High threshold.
Access: Instant."
::= {acPMPSTNChannelsAttributes 1}
acPMPSTNChannelsAttributesInServiceLowThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low threshold.
Access: Instant."
::= {acPMPSTNChannelsAttributes 2}
acPMPSTNChannelsAttributesOutOfServiceHighThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High threshold.
Access: Instant."
::= {acPMPSTNChannelsAttributes 3}
acPMPSTNChannelsAttributesOutOfServiceLowThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low threshold.
Access: Instant."
::= {acPMPSTNChannelsAttributes 4}
acPMPSTNChannelsAttributesInMaintenanceHighThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High threshold.
Access: Instant."
::= {acPMPSTNChannelsAttributes 5}
acPMPSTNChannelsAttributesInMaintenanceLowThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low threshold.
Access: Instant."
::= {acPMPSTNChannelsAttributes 6}
acPMPSTNData OBJECT IDENTIFIER ::= {acPMPSTN 2}
acPMPSTNDataAcPMPSTNTimeFromStartOfInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time in seconds since the start of the current interval.
MIB specific."
::= {acPMPSTNData 1}
-- ****************************************
-- acPMTrunkUtilization table declaration
-- ****************************************
acPMTrunkUtilizationTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMTrunkUtilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of active channels per trunk (index: trunk number)."
::= {acPMPSTNData 21}
-- ****************************************
-- acPMTrunkUtilization table entry
-- ****************************************
acPMTrunkUtilizationEntry OBJECT-TYPE
SYNTAX AcPMTrunkUtilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMTrunkUtilizationTrunkNum,acPMTrunkUtilizationInterval}
::= {acPMTrunkUtilizationTable 1}
-- ****************************************
-- acPMTrunkUtilization TABLE
-- ****************************************
AcPMTrunkUtilizationEntry ::= SEQUENCE {
acPMTrunkUtilizationTrunkNum Unsigned32,
acPMTrunkUtilizationInterval Unsigned32,
acPMTrunkUtilizationVal Gauge32,
acPMTrunkUtilizationAverage Integer32,
acPMTrunkUtilizationMax Integer32,
acPMTrunkUtilizationMin Integer32,
acPMTrunkUtilizationVolume Counter32,
acPMTrunkUtilizationTimeBelowLowThreshold Integer32,
acPMTrunkUtilizationTimeBetweenThresholds Integer32,
acPMTrunkUtilizationTimeAboveHighThreshold Integer32,
acPMTrunkUtilizationFullDayAverage Integer32,
acPMTrunkUtilizationTotal Integer32
}
acPMTrunkUtilizationTrunkNum OBJECT-TYPE
SYNTAX Unsigned32 (0..83)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Trunk number.
0 is the first trunk."
::= {acPMTrunkUtilizationEntry 1}
acPMTrunkUtilizationInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMTrunkUtilizationEntry 2}
acPMTrunkUtilizationVal OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMTrunkUtilizationEntry 3}
acPMTrunkUtilizationAverage OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value within the period time."
::= {acPMTrunkUtilizationEntry 4}
acPMTrunkUtilizationMax OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value within the period time."
::= {acPMTrunkUtilizationEntry 5}
acPMTrunkUtilizationMin OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value within the period time."
::= {acPMTrunkUtilizationEntry 6}
acPMTrunkUtilizationVolume OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Activity volume."
::= {acPMTrunkUtilizationEntry 7}
acPMTrunkUtilizationTimeBelowLowThreshold OBJECT-TYPE
SYNTAX Integer32 (-1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent of interval time for which gauge is below what was determined
as the low threshold."
::= {acPMTrunkUtilizationEntry 8}
acPMTrunkUtilizationTimeBetweenThresholds OBJECT-TYPE
SYNTAX Integer32 (-1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent of interval time for which gauge is above what was determined
as the high threshold."
::= {acPMTrunkUtilizationEntry 9}
acPMTrunkUtilizationTimeAboveHighThreshold OBJECT-TYPE
SYNTAX Integer32 (-1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
::= {acPMTrunkUtilizationEntry 10}
acPMTrunkUtilizationFullDayAverage OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average of full 24 hours."
::= {acPMTrunkUtilizationEntry 11}
acPMTrunkUtilizationTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMTrunkUtilizationEntry 12}
-- ****************************************
-- acPMPSTNTrunkActivitySeconds table declaration
-- ****************************************
acPMPSTNTrunkActivitySecondsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMPSTNTrunkActivitySecondsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Counts activity seconds on the trunk."
::= {acPMPSTNData 22}
-- ****************************************
-- acPMPSTNTrunkActivitySeconds table entry
-- ****************************************
acPMPSTNTrunkActivitySecondsEntry OBJECT-TYPE
SYNTAX AcPMPSTNTrunkActivitySecondsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMPSTNTrunkActivitySecondsTrunkNum,acPMPSTNTrunkActivitySecondsInterval}
::= {acPMPSTNTrunkActivitySecondsTable 1}
-- ****************************************
-- acPMPSTNTrunkActivitySeconds TABLE
-- ****************************************
AcPMPSTNTrunkActivitySecondsEntry ::= SEQUENCE {
acPMPSTNTrunkActivitySecondsTrunkNum Unsigned32,
acPMPSTNTrunkActivitySecondsInterval Unsigned32,
acPMPSTNTrunkActivitySecondsVal Gauge32,
acPMPSTNTrunkActivitySecondsTotal Integer32,
acPMPSTNTrunkActivitySecondsVolume Counter32
}
acPMPSTNTrunkActivitySecondsTrunkNum OBJECT-TYPE
SYNTAX Unsigned32 (0..83)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Trunk number.
0 is the first trunk."
::= {acPMPSTNTrunkActivitySecondsEntry 1}
acPMPSTNTrunkActivitySecondsInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMPSTNTrunkActivitySecondsEntry 2}
acPMPSTNTrunkActivitySecondsVal OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMPSTNTrunkActivitySecondsEntry 3}
acPMPSTNTrunkActivitySecondsTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total since last reset."
::= {acPMPSTNTrunkActivitySecondsEntry 4}
acPMPSTNTrunkActivitySecondsVolume OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Activity volume."
::= {acPMPSTNTrunkActivitySecondsEntry 5}
acPMPSTNChannels OBJECT IDENTIFIER ::= {acPMPSTNData 31}
-- ****************************************
-- acPMPSTNNumOfChannelsInService table declaration
-- ****************************************
acPMPSTNNumOfChannelsInServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMPSTNNumOfChannelsInServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Channels in service, per trunk."
::= {acPMPSTNChannels 1}
-- ****************************************
-- acPMPSTNNumOfChannelsInService table entry
-- ****************************************
acPMPSTNNumOfChannelsInServiceEntry OBJECT-TYPE
SYNTAX AcPMPSTNNumOfChannelsInServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMPSTNNumOfChannelsInServiceTrunkNum,acPMPSTNNumOfChannelsInServiceInterval}
::= {acPMPSTNNumOfChannelsInServiceTable 1}
-- ****************************************
-- acPMPSTNNumOfChannelsInService TABLE
-- ****************************************
AcPMPSTNNumOfChannelsInServiceEntry ::= SEQUENCE {
acPMPSTNNumOfChannelsInServiceTrunkNum Unsigned32,
acPMPSTNNumOfChannelsInServiceInterval Unsigned32,
acPMPSTNNumOfChannelsInServiceVal Gauge32,
acPMPSTNNumOfChannelsInServiceAverage Integer32,
acPMPSTNNumOfChannelsInServiceMax Integer32,
acPMPSTNNumOfChannelsInServiceMin Integer32,
acPMPSTNNumOfChannelsInServiceVolume Counter32
}
acPMPSTNNumOfChannelsInServiceTrunkNum OBJECT-TYPE
SYNTAX Unsigned32 (0..83)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Trunk number.
0 is the first trunk."
::= {acPMPSTNNumOfChannelsInServiceEntry 1}
acPMPSTNNumOfChannelsInServiceInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMPSTNNumOfChannelsInServiceEntry 2}
acPMPSTNNumOfChannelsInServiceVal OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMPSTNNumOfChannelsInServiceEntry 3}
acPMPSTNNumOfChannelsInServiceAverage OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value within the period time."
::= {acPMPSTNNumOfChannelsInServiceEntry 4}
acPMPSTNNumOfChannelsInServiceMax OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value within the period time."
::= {acPMPSTNNumOfChannelsInServiceEntry 5}
acPMPSTNNumOfChannelsInServiceMin OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value within the period time."
::= {acPMPSTNNumOfChannelsInServiceEntry 6}
acPMPSTNNumOfChannelsInServiceVolume OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Activity volume."
::= {acPMPSTNNumOfChannelsInServiceEntry 7}
-- ****************************************
-- acPMPSTNNumOfChannelsOutOfService table declaration
-- ****************************************
acPMPSTNNumOfChannelsOutOfServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMPSTNNumOfChannelsOutOfServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Channels out of service, per trunk."
::= {acPMPSTNChannels 2}
-- ****************************************
-- acPMPSTNNumOfChannelsOutOfService table entry
-- ****************************************
acPMPSTNNumOfChannelsOutOfServiceEntry OBJECT-TYPE
SYNTAX AcPMPSTNNumOfChannelsOutOfServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMPSTNNumOfChannelsOutOfServiceTrunkNum,acPMPSTNNumOfChannelsOutOfServiceInterval}
::= {acPMPSTNNumOfChannelsOutOfServiceTable 1}
-- ****************************************
-- acPMPSTNNumOfChannelsOutOfService TABLE
-- ****************************************
AcPMPSTNNumOfChannelsOutOfServiceEntry ::= SEQUENCE {
acPMPSTNNumOfChannelsOutOfServiceTrunkNum Unsigned32,
acPMPSTNNumOfChannelsOutOfServiceInterval Unsigned32,
acPMPSTNNumOfChannelsOutOfServiceVal Gauge32,
acPMPSTNNumOfChannelsOutOfServiceAverage Integer32,
acPMPSTNNumOfChannelsOutOfServiceMax Integer32,
acPMPSTNNumOfChannelsOutOfServiceMin Integer32,
acPMPSTNNumOfChannelsOutOfServiceVolume Counter32
}
acPMPSTNNumOfChannelsOutOfServiceTrunkNum OBJECT-TYPE
SYNTAX Unsigned32 (0..83)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Trunk number.
0 is the first trunk."
::= {acPMPSTNNumOfChannelsOutOfServiceEntry 1}
acPMPSTNNumOfChannelsOutOfServiceInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMPSTNNumOfChannelsOutOfServiceEntry 2}
acPMPSTNNumOfChannelsOutOfServiceVal OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMPSTNNumOfChannelsOutOfServiceEntry 3}
acPMPSTNNumOfChannelsOutOfServiceAverage OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value within the period time."
::= {acPMPSTNNumOfChannelsOutOfServiceEntry 4}
acPMPSTNNumOfChannelsOutOfServiceMax OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value within the period time."
::= {acPMPSTNNumOfChannelsOutOfServiceEntry 5}
acPMPSTNNumOfChannelsOutOfServiceMin OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value within the period time."
::= {acPMPSTNNumOfChannelsOutOfServiceEntry 6}
acPMPSTNNumOfChannelsOutOfServiceVolume OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Activity volume."
::= {acPMPSTNNumOfChannelsOutOfServiceEntry 7}
-- ****************************************
-- acPMPSTNNumOfChannelsInMaintenance table declaration
-- ****************************************
acPMPSTNNumOfChannelsInMaintenanceTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMPSTNNumOfChannelsInMaintenanceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Channels in maintenance status (not in-service), per trunk."
::= {acPMPSTNChannels 3}
-- ****************************************
-- acPMPSTNNumOfChannelsInMaintenance table entry
-- ****************************************
acPMPSTNNumOfChannelsInMaintenanceEntry OBJECT-TYPE
SYNTAX AcPMPSTNNumOfChannelsInMaintenanceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acPMPSTNNumOfChannelsInMaintenanceTrunkNum,acPMPSTNNumOfChannelsInMaintenanceInterval}
::= {acPMPSTNNumOfChannelsInMaintenanceTable 1}
-- ****************************************
-- acPMPSTNNumOfChannelsInMaintenance TABLE
-- ****************************************
AcPMPSTNNumOfChannelsInMaintenanceEntry ::= SEQUENCE {
acPMPSTNNumOfChannelsInMaintenanceTrunkNum Unsigned32,
acPMPSTNNumOfChannelsInMaintenanceInterval Unsigned32,
acPMPSTNNumOfChannelsInMaintenanceVal Gauge32,
acPMPSTNNumOfChannelsInMaintenanceAverage Integer32,
acPMPSTNNumOfChannelsInMaintenanceMax Integer32,
acPMPSTNNumOfChannelsInMaintenanceMin Integer32,
acPMPSTNNumOfChannelsInMaintenanceVolume Counter32
}
acPMPSTNNumOfChannelsInMaintenanceTrunkNum OBJECT-TYPE
SYNTAX Unsigned32 (0..83)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Trunk number.
0 is the first trunk."
::= {acPMPSTNNumOfChannelsInMaintenanceEntry 1}
acPMPSTNNumOfChannelsInMaintenanceInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMPSTNNumOfChannelsInMaintenanceEntry 2}
acPMPSTNNumOfChannelsInMaintenanceVal OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of gauge or counter."
::= {acPMPSTNNumOfChannelsInMaintenanceEntry 3}
acPMPSTNNumOfChannelsInMaintenanceAverage OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value within the period time."
::= {acPMPSTNNumOfChannelsInMaintenanceEntry 4}
acPMPSTNNumOfChannelsInMaintenanceMax OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value within the period time."
::= {acPMPSTNNumOfChannelsInMaintenanceEntry 5}
acPMPSTNNumOfChannelsInMaintenanceMin OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value within the period time."
::= {acPMPSTNNumOfChannelsInMaintenanceEntry 6}
acPMPSTNNumOfChannelsInMaintenanceVolume OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Activity volume."
::= {acPMPSTNNumOfChannelsInMaintenanceEntry 7}
END