825 lines
		
	
	
		
			24 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			825 lines
		
	
	
		
			24 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
 | 
						|
AC-PM-PSTN-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
 | 
						|
    IMPORTS
 | 
						|
       
 | 
						|
 | 
						|
        OBJECT-TYPE, 
 | 
						|
        MODULE-IDENTITY                             FROM SNMPv2-SMI
 | 
						|
        TAddress, 
 | 
						|
        DisplayString, 
 | 
						|
        DateAndTime, TEXTUAL-CONVENTION             FROM SNMPv2-TC
 | 
						|
        IpAddress                                   FROM RFC1155-SMI
 | 
						|
        Unsigned32,
 | 
						|
		Integer32,
 | 
						|
        enterprises                                 FROM SNMPv2-SMI
 | 
						|
		SnmpAdminString								FROM SNMP-FRAMEWORK-MIB
 | 
						|
		audioCodes,       
 | 
						|
		acRegistrations,
 | 
						|
		acGeneric, 
 | 
						|
		acProducts,acBoardMibs,acPerformance		FROM AUDIOCODES-TYPES-MIB;
 | 
						|
 | 
						|
       
 | 
						|
acPMPSTN  MODULE-IDENTITY       
 | 
						|
    LAST-UPDATED "200902050516Z"          --Thursday, February 05, 2009
 | 
						|
    ORGANIZATION "AudioCodes Ltd"
 | 
						|
    CONTACT-INFO
 | 
						|
    "Postal: Support
 | 
						|
			 AudioCodes LTD
 | 
						|
             1 Hayarden Street
 | 
						|
             Airport City 
 | 
						|
			 Lod, ISRAEL 70151
 | 
						|
     Tel:    972-3-9764000
 | 
						|
     Fax:    972-3-9764040
 | 
						|
     Email:  support@audiocodes.com
 | 
						|
     Web:    www.audiocodes.com"		
 | 
						|
		
 | 
						|
 | 
						|
    DESCRIPTION       
 | 
						|
    "The AC-PM-PSTN MIB offers performance monitoring
 | 
						|
For the PSTN related elements in Audiocodes' devices.
 | 
						|
The Configuration sub-tree is for configuring the interval
 | 
						|
Period length for the entire AC-PM-PSTN MIB, and the 
 | 
						|
different tables' thresholds.
 | 
						|
The Data sub-tree presents the tables of monitored
 | 
						|
elements.
 | 
						|
 | 
						|
Note  - for the entire MIB the value (-1) means the value
 | 
						|
Asked for is either not supported or currently not relevant
 | 
						|
(this is for when values asked for are for intervals not yet
 | 
						|
recorded."
 | 
						|
 | 
						|
 | 
						|
 | 
						|
    ::= {acPerformance 10}  
 | 
						|
 | 
						|
 | 
						|
 | 
						|
 | 
						|
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNConfiguration OBJECT IDENTIFIER ::= {acPMPSTN 1}
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNConfigurationPeriodLength OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..894780)
 | 
						|
       MAX-ACCESS read-write
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Length of monitoring intervals for entire MIB. Time is in minutes.
 | 
						|
Access: Instant."
 | 
						|
       ::= {acPMPSTNConfiguration 1}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNConfigurationResetTotalCounters OBJECT-TYPE
 | 
						|
       SYNTAX INTEGER {
 | 
						|
                  resetCountersDone(1)
 | 
						|
,
 | 
						|
                  resetTotalCounters(2)
 | 
						|
 | 
						|
                  }
 | 
						|
       MAX-ACCESS read-write
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Total-Counters Reset.  To reset the total counters, set the
 | 
						|
value of this object to resetTotalCounters(2).
 | 
						|
Access: Instant."
 | 
						|
       ::= {acPMPSTNConfiguration 2}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMTrunkUtilizationAttributes OBJECT IDENTIFIER ::= {acPMPSTNConfiguration 31}
 | 
						|
 | 
						|
 | 
						|
     acPMTrunkUtilizationAttributesHighThreshold OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..32)
 | 
						|
       MAX-ACCESS read-write
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "High threshold.
 | 
						|
Access: Instant."
 | 
						|
       ::= {acPMTrunkUtilizationAttributes 1}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMTrunkUtilizationAttributesLowThreshold OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..32)
 | 
						|
       MAX-ACCESS read-write
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Low threshold.
 | 
						|
Access: Instant."
 | 
						|
       ::= {acPMTrunkUtilizationAttributes 2}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNChannelsAttributes OBJECT IDENTIFIER ::= {acPMPSTNConfiguration 32}
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNChannelsAttributesInServiceHighThreshold OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..32)
 | 
						|
       MAX-ACCESS read-write
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "High threshold.
 | 
						|
Access: Instant."
 | 
						|
       ::= {acPMPSTNChannelsAttributes 1}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNChannelsAttributesInServiceLowThreshold OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..32)
 | 
						|
       MAX-ACCESS read-write
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Low threshold.
 | 
						|
Access: Instant."
 | 
						|
       ::= {acPMPSTNChannelsAttributes 2}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNChannelsAttributesOutOfServiceHighThreshold OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..32)
 | 
						|
       MAX-ACCESS read-write
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "High threshold.
 | 
						|
Access: Instant."
 | 
						|
       ::= {acPMPSTNChannelsAttributes 3}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNChannelsAttributesOutOfServiceLowThreshold OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..32)
 | 
						|
       MAX-ACCESS read-write
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Low threshold.
 | 
						|
Access: Instant."
 | 
						|
       ::= {acPMPSTNChannelsAttributes 4}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNChannelsAttributesInMaintenanceHighThreshold OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..32)
 | 
						|
       MAX-ACCESS read-write
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "High threshold.
 | 
						|
Access: Instant."
 | 
						|
       ::= {acPMPSTNChannelsAttributes 5}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNChannelsAttributesInMaintenanceLowThreshold OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..32)
 | 
						|
       MAX-ACCESS read-write
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Low threshold.
 | 
						|
Access: Instant."
 | 
						|
       ::= {acPMPSTNChannelsAttributes 6}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNData OBJECT IDENTIFIER ::= {acPMPSTN 2}
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNDataAcPMPSTNTimeFromStartOfInterval OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..2147483647)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "The time in seconds since the start of the current interval.
 | 
						|
MIB specific."
 | 
						|
       ::= {acPMPSTNData 1}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     -- ****************************************
 | 
						|
     -- acPMTrunkUtilization table declaration
 | 
						|
     -- ****************************************
 | 
						|
     acPMTrunkUtilizationTable OBJECT-TYPE
 | 
						|
       SYNTAX SEQUENCE OF AcPMTrunkUtilizationEntry
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Number of active channels per trunk (index: trunk number)."
 | 
						|
       ::= {acPMPSTNData 21}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     -- ****************************************
 | 
						|
     -- acPMTrunkUtilization table entry
 | 
						|
     -- ****************************************
 | 
						|
     acPMTrunkUtilizationEntry OBJECT-TYPE
 | 
						|
       SYNTAX AcPMTrunkUtilizationEntry
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           ""
 | 
						|
       INDEX {acPMTrunkUtilizationTrunkNum,acPMTrunkUtilizationInterval}
 | 
						|
       ::= {acPMTrunkUtilizationTable 1}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     -- ****************************************
 | 
						|
     -- acPMTrunkUtilization TABLE
 | 
						|
     -- ****************************************
 | 
						|
     AcPMTrunkUtilizationEntry ::= SEQUENCE {
 | 
						|
       acPMTrunkUtilizationTrunkNum                    Unsigned32,
 | 
						|
       acPMTrunkUtilizationInterval                    Unsigned32,
 | 
						|
       acPMTrunkUtilizationVal                         Gauge32,
 | 
						|
       acPMTrunkUtilizationAverage                     Integer32,
 | 
						|
       acPMTrunkUtilizationMax                         Integer32,
 | 
						|
       acPMTrunkUtilizationMin                         Integer32,
 | 
						|
       acPMTrunkUtilizationVolume                      Counter32,
 | 
						|
       acPMTrunkUtilizationTimeBelowLowThreshold       Integer32,
 | 
						|
       acPMTrunkUtilizationTimeBetweenThresholds       Integer32,
 | 
						|
       acPMTrunkUtilizationTimeAboveHighThreshold      Integer32,
 | 
						|
       acPMTrunkUtilizationFullDayAverage              Integer32,
 | 
						|
       acPMTrunkUtilizationTotal                       Integer32
 | 
						|
     }
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMTrunkUtilizationTrunkNum OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..83)
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Trunk number.
 | 
						|
0 is the first trunk."
 | 
						|
       ::= {acPMTrunkUtilizationEntry 1}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMTrunkUtilizationInterval OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..2)
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Interval index.
 | 
						|
0 - current period (incomplete monitoring - mid period).
 | 
						|
1 - Last full period.
 | 
						|
2 - One before last."
 | 
						|
       ::= {acPMTrunkUtilizationEntry 2}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMTrunkUtilizationVal OBJECT-TYPE
 | 
						|
       SYNTAX Gauge32
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Value of gauge or counter."
 | 
						|
       ::= {acPMTrunkUtilizationEntry 3}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMTrunkUtilizationAverage OBJECT-TYPE
 | 
						|
       SYNTAX Integer32 (-1..2147483647)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Average value within the period time."
 | 
						|
       ::= {acPMTrunkUtilizationEntry 4}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMTrunkUtilizationMax OBJECT-TYPE
 | 
						|
       SYNTAX Integer32 (-1..2147483647)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Maximum value within the period time."
 | 
						|
       ::= {acPMTrunkUtilizationEntry 5}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMTrunkUtilizationMin OBJECT-TYPE
 | 
						|
       SYNTAX Integer32 (-1..2147483647)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Minimum value within the period time."
 | 
						|
       ::= {acPMTrunkUtilizationEntry 6}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMTrunkUtilizationVolume OBJECT-TYPE
 | 
						|
       SYNTAX Counter32
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Activity volume."
 | 
						|
       ::= {acPMTrunkUtilizationEntry 7}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMTrunkUtilizationTimeBelowLowThreshold OBJECT-TYPE
 | 
						|
       SYNTAX Integer32 (-1..100)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Percent of interval time for which gauge is below what was determined
 | 
						|
as the low threshold."
 | 
						|
       ::= {acPMTrunkUtilizationEntry 8}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMTrunkUtilizationTimeBetweenThresholds OBJECT-TYPE
 | 
						|
       SYNTAX Integer32 (-1..100)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Percent of interval time for which gauge is above what was determined
 | 
						|
as the high threshold."
 | 
						|
       ::= {acPMTrunkUtilizationEntry 9}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMTrunkUtilizationTimeAboveHighThreshold OBJECT-TYPE
 | 
						|
       SYNTAX Integer32 (-1..100)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Percent of interval time for which gauge is between what were
 | 
						|
determined as the low and high thresholds."
 | 
						|
       ::= {acPMTrunkUtilizationEntry 10}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMTrunkUtilizationFullDayAverage OBJECT-TYPE
 | 
						|
       SYNTAX Integer32 (-1..2147483647)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "The average of full 24 hours."
 | 
						|
       ::= {acPMTrunkUtilizationEntry 11}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMTrunkUtilizationTotal OBJECT-TYPE
 | 
						|
       SYNTAX Integer32 (-1..2147483647)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Total since last reset."
 | 
						|
       ::= {acPMTrunkUtilizationEntry 12}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     -- ****************************************
 | 
						|
     -- acPMPSTNTrunkActivitySeconds table declaration
 | 
						|
     -- ****************************************
 | 
						|
     acPMPSTNTrunkActivitySecondsTable OBJECT-TYPE
 | 
						|
       SYNTAX SEQUENCE OF AcPMPSTNTrunkActivitySecondsEntry
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Counts activity seconds on the trunk."
 | 
						|
       ::= {acPMPSTNData 22}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     -- ****************************************
 | 
						|
     -- acPMPSTNTrunkActivitySeconds table entry
 | 
						|
     -- ****************************************
 | 
						|
     acPMPSTNTrunkActivitySecondsEntry OBJECT-TYPE
 | 
						|
       SYNTAX AcPMPSTNTrunkActivitySecondsEntry
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           ""
 | 
						|
       INDEX {acPMPSTNTrunkActivitySecondsTrunkNum,acPMPSTNTrunkActivitySecondsInterval}
 | 
						|
       ::= {acPMPSTNTrunkActivitySecondsTable 1}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     -- ****************************************
 | 
						|
     -- acPMPSTNTrunkActivitySeconds TABLE
 | 
						|
     -- ****************************************
 | 
						|
     AcPMPSTNTrunkActivitySecondsEntry ::= SEQUENCE {
 | 
						|
       acPMPSTNTrunkActivitySecondsTrunkNum            Unsigned32,
 | 
						|
       acPMPSTNTrunkActivitySecondsInterval            Unsigned32,
 | 
						|
       acPMPSTNTrunkActivitySecondsVal                 Gauge32,
 | 
						|
       acPMPSTNTrunkActivitySecondsTotal               Integer32,
 | 
						|
       acPMPSTNTrunkActivitySecondsVolume              Counter32
 | 
						|
     }
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNTrunkActivitySecondsTrunkNum OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..83)
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Trunk number.
 | 
						|
0 is the first trunk."
 | 
						|
       ::= {acPMPSTNTrunkActivitySecondsEntry 1}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNTrunkActivitySecondsInterval OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..2)
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Interval index.
 | 
						|
0 - current period (incomplete monitoring - mid period).
 | 
						|
1 - Last full period.
 | 
						|
2 - One before last."
 | 
						|
       ::= {acPMPSTNTrunkActivitySecondsEntry 2}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNTrunkActivitySecondsVal OBJECT-TYPE
 | 
						|
       SYNTAX Gauge32
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Value of gauge or counter."
 | 
						|
       ::= {acPMPSTNTrunkActivitySecondsEntry 3}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNTrunkActivitySecondsTotal OBJECT-TYPE
 | 
						|
       SYNTAX Integer32 (-1..2147483647)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Total since last reset."
 | 
						|
       ::= {acPMPSTNTrunkActivitySecondsEntry 4}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNTrunkActivitySecondsVolume OBJECT-TYPE
 | 
						|
       SYNTAX Counter32
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Activity volume."
 | 
						|
       ::= {acPMPSTNTrunkActivitySecondsEntry 5}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNChannels OBJECT IDENTIFIER ::= {acPMPSTNData 31}
 | 
						|
 | 
						|
 | 
						|
     -- ****************************************
 | 
						|
     -- acPMPSTNNumOfChannelsInService table declaration
 | 
						|
     -- ****************************************
 | 
						|
     acPMPSTNNumOfChannelsInServiceTable OBJECT-TYPE
 | 
						|
       SYNTAX SEQUENCE OF AcPMPSTNNumOfChannelsInServiceEntry
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Channels in service, per trunk."
 | 
						|
       ::= {acPMPSTNChannels 1}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     -- ****************************************
 | 
						|
     -- acPMPSTNNumOfChannelsInService table entry
 | 
						|
     -- ****************************************
 | 
						|
     acPMPSTNNumOfChannelsInServiceEntry OBJECT-TYPE
 | 
						|
       SYNTAX AcPMPSTNNumOfChannelsInServiceEntry
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           ""
 | 
						|
       INDEX {acPMPSTNNumOfChannelsInServiceTrunkNum,acPMPSTNNumOfChannelsInServiceInterval}
 | 
						|
       ::= {acPMPSTNNumOfChannelsInServiceTable 1}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     -- ****************************************
 | 
						|
     -- acPMPSTNNumOfChannelsInService TABLE
 | 
						|
     -- ****************************************
 | 
						|
     AcPMPSTNNumOfChannelsInServiceEntry ::= SEQUENCE {
 | 
						|
       acPMPSTNNumOfChannelsInServiceTrunkNum          Unsigned32,
 | 
						|
       acPMPSTNNumOfChannelsInServiceInterval          Unsigned32,
 | 
						|
       acPMPSTNNumOfChannelsInServiceVal               Gauge32,
 | 
						|
       acPMPSTNNumOfChannelsInServiceAverage           Integer32,
 | 
						|
       acPMPSTNNumOfChannelsInServiceMax               Integer32,
 | 
						|
       acPMPSTNNumOfChannelsInServiceMin               Integer32,
 | 
						|
       acPMPSTNNumOfChannelsInServiceVolume            Counter32
 | 
						|
     }
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsInServiceTrunkNum OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..83)
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Trunk number.
 | 
						|
0 is the first trunk."
 | 
						|
       ::= {acPMPSTNNumOfChannelsInServiceEntry 1}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsInServiceInterval OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..2)
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Interval index.
 | 
						|
0 - current period (incomplete monitoring - mid period).
 | 
						|
1 - Last full period.
 | 
						|
2 - One before last."
 | 
						|
       ::= {acPMPSTNNumOfChannelsInServiceEntry 2}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsInServiceVal OBJECT-TYPE
 | 
						|
       SYNTAX Gauge32
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Value of gauge or counter."
 | 
						|
       ::= {acPMPSTNNumOfChannelsInServiceEntry 3}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsInServiceAverage OBJECT-TYPE
 | 
						|
       SYNTAX Integer32 (-1..2147483647)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Average value within the period time."
 | 
						|
       ::= {acPMPSTNNumOfChannelsInServiceEntry 4}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsInServiceMax OBJECT-TYPE
 | 
						|
       SYNTAX Integer32 (-1..2147483647)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Maximum value within the period time."
 | 
						|
       ::= {acPMPSTNNumOfChannelsInServiceEntry 5}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsInServiceMin OBJECT-TYPE
 | 
						|
       SYNTAX Integer32 (-1..2147483647)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Minimum value within the period time."
 | 
						|
       ::= {acPMPSTNNumOfChannelsInServiceEntry 6}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsInServiceVolume OBJECT-TYPE
 | 
						|
       SYNTAX Counter32
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Activity volume."
 | 
						|
       ::= {acPMPSTNNumOfChannelsInServiceEntry 7}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     -- ****************************************
 | 
						|
     -- acPMPSTNNumOfChannelsOutOfService table declaration
 | 
						|
     -- ****************************************
 | 
						|
     acPMPSTNNumOfChannelsOutOfServiceTable OBJECT-TYPE
 | 
						|
       SYNTAX SEQUENCE OF AcPMPSTNNumOfChannelsOutOfServiceEntry
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Channels out of service, per trunk."
 | 
						|
       ::= {acPMPSTNChannels 2}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     -- ****************************************
 | 
						|
     -- acPMPSTNNumOfChannelsOutOfService table entry
 | 
						|
     -- ****************************************
 | 
						|
     acPMPSTNNumOfChannelsOutOfServiceEntry OBJECT-TYPE
 | 
						|
       SYNTAX AcPMPSTNNumOfChannelsOutOfServiceEntry
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           ""
 | 
						|
       INDEX {acPMPSTNNumOfChannelsOutOfServiceTrunkNum,acPMPSTNNumOfChannelsOutOfServiceInterval}
 | 
						|
       ::= {acPMPSTNNumOfChannelsOutOfServiceTable 1}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     -- ****************************************
 | 
						|
     -- acPMPSTNNumOfChannelsOutOfService TABLE
 | 
						|
     -- ****************************************
 | 
						|
     AcPMPSTNNumOfChannelsOutOfServiceEntry ::= SEQUENCE {
 | 
						|
       acPMPSTNNumOfChannelsOutOfServiceTrunkNum       Unsigned32,
 | 
						|
       acPMPSTNNumOfChannelsOutOfServiceInterval       Unsigned32,
 | 
						|
       acPMPSTNNumOfChannelsOutOfServiceVal            Gauge32,
 | 
						|
       acPMPSTNNumOfChannelsOutOfServiceAverage        Integer32,
 | 
						|
       acPMPSTNNumOfChannelsOutOfServiceMax            Integer32,
 | 
						|
       acPMPSTNNumOfChannelsOutOfServiceMin            Integer32,
 | 
						|
       acPMPSTNNumOfChannelsOutOfServiceVolume         Counter32
 | 
						|
     }
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsOutOfServiceTrunkNum OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..83)
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Trunk number.
 | 
						|
0 is the first trunk."
 | 
						|
       ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 1}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsOutOfServiceInterval OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..2)
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Interval index.
 | 
						|
0 - current period (incomplete monitoring - mid period).
 | 
						|
1 - Last full period.
 | 
						|
2 - One before last."
 | 
						|
       ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 2}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsOutOfServiceVal OBJECT-TYPE
 | 
						|
       SYNTAX Gauge32
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Value of gauge or counter."
 | 
						|
       ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 3}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsOutOfServiceAverage OBJECT-TYPE
 | 
						|
       SYNTAX Integer32 (-1..2147483647)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Average value within the period time."
 | 
						|
       ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 4}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsOutOfServiceMax OBJECT-TYPE
 | 
						|
       SYNTAX Integer32 (-1..2147483647)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Maximum value within the period time."
 | 
						|
       ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 5}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsOutOfServiceMin OBJECT-TYPE
 | 
						|
       SYNTAX Integer32 (-1..2147483647)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Minimum value within the period time."
 | 
						|
       ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 6}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsOutOfServiceVolume OBJECT-TYPE
 | 
						|
       SYNTAX Counter32
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Activity volume."
 | 
						|
       ::= {acPMPSTNNumOfChannelsOutOfServiceEntry 7}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     -- ****************************************
 | 
						|
     -- acPMPSTNNumOfChannelsInMaintenance table declaration
 | 
						|
     -- ****************************************
 | 
						|
     acPMPSTNNumOfChannelsInMaintenanceTable OBJECT-TYPE
 | 
						|
       SYNTAX SEQUENCE OF AcPMPSTNNumOfChannelsInMaintenanceEntry
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Channels in maintenance status (not in-service), per trunk."
 | 
						|
       ::= {acPMPSTNChannels 3}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     -- ****************************************
 | 
						|
     -- acPMPSTNNumOfChannelsInMaintenance table entry
 | 
						|
     -- ****************************************
 | 
						|
     acPMPSTNNumOfChannelsInMaintenanceEntry OBJECT-TYPE
 | 
						|
       SYNTAX AcPMPSTNNumOfChannelsInMaintenanceEntry
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           ""
 | 
						|
       INDEX {acPMPSTNNumOfChannelsInMaintenanceTrunkNum,acPMPSTNNumOfChannelsInMaintenanceInterval}
 | 
						|
       ::= {acPMPSTNNumOfChannelsInMaintenanceTable 1}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     -- ****************************************
 | 
						|
     -- acPMPSTNNumOfChannelsInMaintenance TABLE
 | 
						|
     -- ****************************************
 | 
						|
     AcPMPSTNNumOfChannelsInMaintenanceEntry ::= SEQUENCE {
 | 
						|
       acPMPSTNNumOfChannelsInMaintenanceTrunkNum      Unsigned32,
 | 
						|
       acPMPSTNNumOfChannelsInMaintenanceInterval      Unsigned32,
 | 
						|
       acPMPSTNNumOfChannelsInMaintenanceVal           Gauge32,
 | 
						|
       acPMPSTNNumOfChannelsInMaintenanceAverage       Integer32,
 | 
						|
       acPMPSTNNumOfChannelsInMaintenanceMax           Integer32,
 | 
						|
       acPMPSTNNumOfChannelsInMaintenanceMin           Integer32,
 | 
						|
       acPMPSTNNumOfChannelsInMaintenanceVolume        Counter32
 | 
						|
     }
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsInMaintenanceTrunkNum OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..83)
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Trunk number.
 | 
						|
0 is the first trunk."
 | 
						|
       ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 1}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsInMaintenanceInterval OBJECT-TYPE
 | 
						|
       SYNTAX Unsigned32 (0..2)
 | 
						|
       MAX-ACCESS not-accessible
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Interval index.
 | 
						|
0 - current period (incomplete monitoring - mid period).
 | 
						|
1 - Last full period.
 | 
						|
2 - One before last."
 | 
						|
       ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 2}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsInMaintenanceVal OBJECT-TYPE
 | 
						|
       SYNTAX Gauge32
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Value of gauge or counter."
 | 
						|
       ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 3}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsInMaintenanceAverage OBJECT-TYPE
 | 
						|
       SYNTAX Integer32 (-1..2147483647)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Average value within the period time."
 | 
						|
       ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 4}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsInMaintenanceMax OBJECT-TYPE
 | 
						|
       SYNTAX Integer32 (-1..2147483647)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Maximum value within the period time."
 | 
						|
       ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 5}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsInMaintenanceMin OBJECT-TYPE
 | 
						|
       SYNTAX Integer32 (-1..2147483647)
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Minimum value within the period time."
 | 
						|
       ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 6}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
     acPMPSTNNumOfChannelsInMaintenanceVolume OBJECT-TYPE
 | 
						|
       SYNTAX Counter32
 | 
						|
       MAX-ACCESS read-only
 | 
						|
       STATUS current
 | 
						|
       DESCRIPTION
 | 
						|
           "Activity volume."
 | 
						|
       ::= {acPMPSTNNumOfChannelsInMaintenanceEntry 7}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
 | 
						|
 | 
						|
END
 |