mibs/MIBS/bluecoat/BLUECOAT-SG-SENSOR-MIB

245 lines
9.1 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
BLUECOAT-SG-SENSOR-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, TimeStamp, TruthValue, DisplayString
FROM SNMPv2-TC
blueCoatMgmt
FROM BLUECOAT-MIB;
deviceSensorMIB MODULE-IDENTITY
LAST-UPDATED "201511260300Z"
ORGANIZATION "Blue Coat Systems, Inc."
CONTACT-INFO "support.services@bluecoat.com
http://www.bluecoat.com"
DESCRIPTION "The sensor MIB is used to monitor
the values of sensors"
REVISION "201511260300Z"
DESCRIPTION "Add new value (notInstalled) to SensorStatus"
REVISION "201307110300Z"
DESCRIPTION "Access level for deviceSensorTrapEnabled changed."
REVISION "200711050300Z"
DESCRIPTION "Minor corrections and reformatting."
REVISION "200211060300Z"
DESCRIPTION "Initial revision of this MIB."
::= { blueCoatMgmt 1 }
deviceSensorMIBObjects
OBJECT IDENTIFIER ::= { deviceSensorMIB 1 }
deviceSensorMIBNotifications
OBJECT IDENTIFIER ::= { deviceSensorMIB 2 }
deviceSensorMIBNotificationsPrefix
OBJECT IDENTIFIER ::= { deviceSensorMIBNotifications 0 }
-- textual conventions
SensorUnits ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Sensor measurement unit types. Valid values are:
other(1) - a measure other than those listed below.
truthvalue(2) - value takes { true(1), false(2) }.
specialEnum(3) - value takes user defined enumerated values.
volts(4) - electrical potential.
celsius(5) - temperature.
rpm(6) - revolutions per minute."
SYNTAX INTEGER {
other(1),
truthvalue(2),
specialEnum(3),
volts(4),
celsius(5),
rpm(6)
}
SensorCode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Interpretation of the current sensor value."
SYNTAX INTEGER {
ok(1),
unknown(2),
notInstalled(3),
voltageLowWarning(4),
voltageLowCritical(5),
noPower(6),
voltageHighWarning(7),
voltageHighCritical(8),
voltageHighSevere(9),
temperatureHighWarning(10),
temperatureHighCritical(11),
temperatureHighSevere(12),
fanSlowWarning(13),
fanSlowCritical(14),
fanStopped(15)
}
ExpBase10 ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION "Exponent base 10 for the current sensor value.
For example '-1' means value*(1/10)."
SYNTAX Integer32 (-24..24)
SensorValue ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION "For sensors that measure volts and celsius,
this item is a fixed point number.
For sensors that measure rpm, this item
can take only nonnegative values.
For sensors of type truthvalue, this item
can take only two values: true(1), false(2).
For sensors of type specialEnum, this item
can take any value."
SYNTAX Integer32 (-1000000000..1000000000)
SensorStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Indicates the operational status of the sensor.
ok(1) means the agent can read the sensor value.
unavailable(2) means that the agent presently
can not report the sensor value.
nonoperational(3) means that the sensor is broken.
notInstalled(4) means that the sensor or device is not present."
SYNTAX INTEGER {
ok(1),
unavailable(2),
nonoperational(3),
notInstalled(4)
}
--
-- MIB variables
--
deviceSensorValues
OBJECT IDENTIFIER ::= { deviceSensorMIBObjects 1 }
--
-- deviceSensorValueTable
--
deviceSensorValueTable OBJECT-TYPE
SYNTAX SEQUENCE OF DeviceSensorValueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of sensors."
::= { deviceSensorValues 1 }
deviceSensorValueEntry OBJECT-TYPE
SYNTAX DeviceSensorValueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An deviceSensorValueTable entry describes the
present reading of a sensor, the measurement units
and sensor operational status."
INDEX { deviceSensorIndex }
::= { deviceSensorValueTable 1 }
DeviceSensorValueEntry ::= SEQUENCE {
deviceSensorIndex INTEGER,
deviceSensorTrapEnabled TruthValue,
deviceSensorUnits SensorUnits,
deviceSensorScale ExpBase10,
deviceSensorValue SensorValue,
deviceSensorCode SensorCode,
deviceSensorStatus SensorStatus,
deviceSensorTimeStamp TimeStamp,
deviceSensorName DisplayString
}
deviceSensorIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An arbitrary value which uniquely identifies the sensor"
::= { deviceSensorValueEntry 1 }
deviceSensorTrapEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This variable controls generation of
deviceSensorTrap for this sensor.
When this variable is true(1), generation of
deviceSensorTrap is enabled. When this variable
is false(2), generation of deviceSensorTrap is
disabled. The default start-up value is true(1)."
::= { deviceSensorValueEntry 2 }
deviceSensorUnits OBJECT-TYPE
SYNTAX SensorUnits
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This variable indicates the type of data
reported by the deviceSensorValue.
This variable is set by the agent at start-up
and the value does not change during operation."
::= { deviceSensorValueEntry 3 }
deviceSensorScale OBJECT-TYPE
SYNTAX ExpBase10
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Power of 10 to apply to the value
reported by the deviceSensorValue.
This variable is set by the agent at start-up
and the value does not change during operation."
::= { deviceSensorValueEntry 4 }
deviceSensorValue OBJECT-TYPE
SYNTAX SensorValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This variable reports the most recent measurement
seen by the sensor. To correctly display or interpret
this variable's value, you must also know
deviceSensorUnits."
::= { deviceSensorValueEntry 5 }
deviceSensorCode OBJECT-TYPE
SYNTAX SensorCode
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This variable reports how to interpret
deviceSensorValue for the sensor."
::= { deviceSensorValueEntry 6 }
deviceSensorStatus OBJECT-TYPE
SYNTAX SensorStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This variable indicates the present operational
status of the sensor."
::= { deviceSensorValueEntry 7 }
deviceSensorTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
UNITS "Hundredths of seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This variable indicates the age of the value
reported by deviceSensorValue."
::= { deviceSensorValueEntry 8 }
deviceSensorName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The textual name of the sensor."
::= { deviceSensorValueEntry 9 }
--
-- notifications
--
deviceSensorTrap NOTIFICATION-TYPE
OBJECTS { deviceSensorName, deviceSensorValue, deviceSensorCode }
STATUS current
DESCRIPTION "The sensor value warrants a notification."
::= { deviceSensorMIBNotificationsPrefix 1 }
END