BLUECOAT-SG-SENSOR-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, TimeStamp, TruthValue, DisplayString
|
|
FROM SNMPv2-TC
|
|
blueCoatMgmt
|
|
FROM BLUECOAT-MIB;
|
|
|
|
deviceSensorMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201511260300Z"
|
|
ORGANIZATION "Blue Coat Systems, Inc."
|
|
CONTACT-INFO "support.services@bluecoat.com
|
|
http://www.bluecoat.com"
|
|
DESCRIPTION "The sensor MIB is used to monitor
|
|
the values of sensors"
|
|
REVISION "201511260300Z"
|
|
DESCRIPTION "Add new value (notInstalled) to SensorStatus"
|
|
REVISION "201307110300Z"
|
|
DESCRIPTION "Access level for deviceSensorTrapEnabled changed."
|
|
REVISION "200711050300Z"
|
|
DESCRIPTION "Minor corrections and reformatting."
|
|
REVISION "200211060300Z"
|
|
DESCRIPTION "Initial revision of this MIB."
|
|
::= { blueCoatMgmt 1 }
|
|
|
|
deviceSensorMIBObjects
|
|
OBJECT IDENTIFIER ::= { deviceSensorMIB 1 }
|
|
|
|
deviceSensorMIBNotifications
|
|
OBJECT IDENTIFIER ::= { deviceSensorMIB 2 }
|
|
|
|
deviceSensorMIBNotificationsPrefix
|
|
OBJECT IDENTIFIER ::= { deviceSensorMIBNotifications 0 }
|
|
|
|
-- textual conventions
|
|
|
|
SensorUnits ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Sensor measurement unit types. Valid values are:
|
|
other(1) - a measure other than those listed below.
|
|
truthvalue(2) - value takes { true(1), false(2) }.
|
|
specialEnum(3) - value takes user defined enumerated values.
|
|
volts(4) - electrical potential.
|
|
celsius(5) - temperature.
|
|
rpm(6) - revolutions per minute."
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
truthvalue(2),
|
|
specialEnum(3),
|
|
volts(4),
|
|
celsius(5),
|
|
rpm(6)
|
|
}
|
|
|
|
SensorCode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Interpretation of the current sensor value."
|
|
SYNTAX INTEGER {
|
|
ok(1),
|
|
unknown(2),
|
|
notInstalled(3),
|
|
voltageLowWarning(4),
|
|
voltageLowCritical(5),
|
|
noPower(6),
|
|
voltageHighWarning(7),
|
|
voltageHighCritical(8),
|
|
voltageHighSevere(9),
|
|
temperatureHighWarning(10),
|
|
temperatureHighCritical(11),
|
|
temperatureHighSevere(12),
|
|
fanSlowWarning(13),
|
|
fanSlowCritical(14),
|
|
fanStopped(15)
|
|
}
|
|
|
|
ExpBase10 ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION "Exponent base 10 for the current sensor value.
|
|
For example '-1' means value*(1/10)."
|
|
SYNTAX Integer32 (-24..24)
|
|
|
|
SensorValue ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION "For sensors that measure volts and celsius,
|
|
this item is a fixed point number.
|
|
For sensors that measure rpm, this item
|
|
can take only nonnegative values.
|
|
For sensors of type truthvalue, this item
|
|
can take only two values: true(1), false(2).
|
|
For sensors of type specialEnum, this item
|
|
can take any value."
|
|
SYNTAX Integer32 (-1000000000..1000000000)
|
|
|
|
SensorStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Indicates the operational status of the sensor.
|
|
ok(1) means the agent can read the sensor value.
|
|
unavailable(2) means that the agent presently
|
|
can not report the sensor value.
|
|
nonoperational(3) means that the sensor is broken.
|
|
notInstalled(4) means that the sensor or device is not present."
|
|
SYNTAX INTEGER {
|
|
ok(1),
|
|
unavailable(2),
|
|
nonoperational(3),
|
|
notInstalled(4)
|
|
}
|
|
|
|
--
|
|
-- MIB variables
|
|
--
|
|
|
|
deviceSensorValues
|
|
OBJECT IDENTIFIER ::= { deviceSensorMIBObjects 1 }
|
|
|
|
--
|
|
-- deviceSensorValueTable
|
|
--
|
|
|
|
deviceSensorValueTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DeviceSensorValueEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of sensors."
|
|
::= { deviceSensorValues 1 }
|
|
|
|
deviceSensorValueEntry OBJECT-TYPE
|
|
SYNTAX DeviceSensorValueEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An deviceSensorValueTable entry describes the
|
|
present reading of a sensor, the measurement units
|
|
and sensor operational status."
|
|
INDEX { deviceSensorIndex }
|
|
::= { deviceSensorValueTable 1 }
|
|
|
|
DeviceSensorValueEntry ::= SEQUENCE {
|
|
deviceSensorIndex INTEGER,
|
|
deviceSensorTrapEnabled TruthValue,
|
|
deviceSensorUnits SensorUnits,
|
|
deviceSensorScale ExpBase10,
|
|
deviceSensorValue SensorValue,
|
|
deviceSensorCode SensorCode,
|
|
deviceSensorStatus SensorStatus,
|
|
deviceSensorTimeStamp TimeStamp,
|
|
deviceSensorName DisplayString
|
|
}
|
|
|
|
deviceSensorIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An arbitrary value which uniquely identifies the sensor"
|
|
::= { deviceSensorValueEntry 1 }
|
|
|
|
deviceSensorTrapEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This variable controls generation of
|
|
deviceSensorTrap for this sensor.
|
|
When this variable is true(1), generation of
|
|
deviceSensorTrap is enabled. When this variable
|
|
is false(2), generation of deviceSensorTrap is
|
|
disabled. The default start-up value is true(1)."
|
|
::= { deviceSensorValueEntry 2 }
|
|
|
|
deviceSensorUnits OBJECT-TYPE
|
|
SYNTAX SensorUnits
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This variable indicates the type of data
|
|
reported by the deviceSensorValue.
|
|
This variable is set by the agent at start-up
|
|
and the value does not change during operation."
|
|
::= { deviceSensorValueEntry 3 }
|
|
|
|
deviceSensorScale OBJECT-TYPE
|
|
SYNTAX ExpBase10
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power of 10 to apply to the value
|
|
reported by the deviceSensorValue.
|
|
This variable is set by the agent at start-up
|
|
and the value does not change during operation."
|
|
::= { deviceSensorValueEntry 4 }
|
|
|
|
deviceSensorValue OBJECT-TYPE
|
|
SYNTAX SensorValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This variable reports the most recent measurement
|
|
seen by the sensor. To correctly display or interpret
|
|
this variable's value, you must also know
|
|
deviceSensorUnits."
|
|
::= { deviceSensorValueEntry 5 }
|
|
|
|
deviceSensorCode OBJECT-TYPE
|
|
SYNTAX SensorCode
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This variable reports how to interpret
|
|
deviceSensorValue for the sensor."
|
|
::= { deviceSensorValueEntry 6 }
|
|
|
|
deviceSensorStatus OBJECT-TYPE
|
|
SYNTAX SensorStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This variable indicates the present operational
|
|
status of the sensor."
|
|
::= { deviceSensorValueEntry 7 }
|
|
|
|
deviceSensorTimeStamp OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
UNITS "Hundredths of seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This variable indicates the age of the value
|
|
reported by deviceSensorValue."
|
|
::= { deviceSensorValueEntry 8 }
|
|
|
|
deviceSensorName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The textual name of the sensor."
|
|
::= { deviceSensorValueEntry 9 }
|
|
|
|
--
|
|
-- notifications
|
|
--
|
|
|
|
deviceSensorTrap NOTIFICATION-TYPE
|
|
OBJECTS { deviceSensorName, deviceSensorValue, deviceSensorCode }
|
|
STATUS current
|
|
DESCRIPTION "The sensor value warrants a notification."
|
|
::= { deviceSensorMIBNotificationsPrefix 1 }
|
|
|
|
END
|