mibs/MIBS/calix/E5-120-MIB

10452 lines
280 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- $Log: E5-120-MIB.mib $
-- Revision 1.67 2011/04/28 03:38:13 Alex.Shih
-- Revision 1.66 2011/03/10 09:37:48 swee
-- Remove supported in R5.x or later version info
-- Revision 1.65 2011/02/09 00:24:59 Alex.Shih
-- Revision 1.65 2011/02/09 00:09:50 Alex.Shih
-- Revision 1.64 2011/01/27 09:24:10 Alex.Shih
-- Revision 1.63 2011/01/24 06:02:44 Alex.Shih
-- Revision 1.62 2011/01/07 07:32:03 cylien
-- fix compile error of mibble
-- Revision 1.61 2010/11/15 11:01:01 Alex.Shih
-- Revision 1.60 2010/11/12 02:58:57 cylien
-- Revision 1.59 2010/11/03 11:00:56 john
-- Revision 1.58 2010/10/26 01:35:33 DavidGong
-- Revision 1.57 2010/10/25 10:07:59 Alex.Shih
-- Revision 1.56 2010/10/14 08:58:32 cylien
-- Revision 1.55 2010/09/30 08:23:27 Alex.Shih
-- Revision 1.54 2010/09/30 04:12:02 cylien
-- Revision 1.53 2010/09/29 02:29:27 cylien
-- Revision 1.52 2010/09/29 01:18:50 john
-- Revision 1.51 2010/09/28 01:01:45 DavidGong
-- Revision 1.50 2010/09/23 07:59:17 cylien
-- Revision 1.49 2010/09/16 10:34:06 DavidGong
-- Revision 1.48 2010/09/08 07:02:34 Alex.Shih
-- Revision 1.47 2010/09/08 03:47:53 Alex.Shih
-- Revision 1.46 2010/08/27 09:00:40 John
-- Revision 1.45 2010/08/27 05:45:47 Alex.Shih
-- Revision 1.44 2010/08/10 07:47:54 Alex.Shih
-- Revision 1.43 2010/07/19 05:35:13 John
-- Revision 1.42 2010/07/17 05:59:03 Alex.Shih
-- Revision 1.41 2010/07/16 09:19:43 cylien
-- Revision 1.40 2010/07/09 11:03:17 John
-- Revision 1.39 2010/07/01 11:38:20 davidgong
-- Revision 1.38 2010/07/01 11:12:01 davidgong
-- Revision 1.37 2010/06/30 07:01:19 Alex.Shih
-- Revision 1.36 2010/06/29 06:43:44 Alex.Shih
-- Revision 1.35 2010/06/28 17:05:02 John
-- Revision 1.33 2010/06/24 07:47:21 davidgong
-- Revision 1.32 2010/06/24 05:28:14 davidgong
-- Revision 1.31 2010/06/08 03:52:08 cylien
-- Revision 1.30 2010/06/07 00:57:38 davidgong
-- Revision 1.29 2010/06/03 12:06:07 JeFF
-- Revision 1.28 2010/06/02 01:18:24 Alex.Shih
-- Revision 1.27 2010/05/21 03:57:37 maverick
-- Revision 1.26 2010/04/23 10:46:29 maverick
-- Revision 1.25 2009/11/26 13:06:56 maverick
-- add comment to obsoleted mib entries, mibble checked
-- Revision 1.24 2009/09/15 05:51:30 maverick
-- Revision 1.23 2009/07/27 08:16:55 niceguy
-- Revision 1.22 2009/07/10 10:39:39 maverick
-- Revision 1.21 2009/06/26 11:01:55 John
-- Revision 1.20 2009/06/25 02:47:25 niceguy
-- Revision 1.19 2009/06/10 02:26:38 John
-- Revision 1.18 2009/05/21 12:28:27 maverick
-- Revision 1.17 2009/05/21 04:05:18 John
-- Revision 1.16 2009/05/20 13:04:20 maverick
-- Revision 1.15 2009/05/20 00:58:57 maverick
-- Revision 1.14 2009/04/29 09:45:26 Ives
-- Revision 1.13 2009/04/29 05:51:21 niceguy
-- Revision 1.12 2009/04/21 12:25:22 Ives
-- Revision 1.10 2008/11/12 08:19:34 kenny
-- Revision 1.9 2008/09/26 10:45:17 niceguy
-- Revision 1.8 2008/09/26 05:51:34 maverick
-- Revision 1.7 2008/09/16 08:11:26 kenny
-- Revision 1.6 2008/08/25 07:12:03 kenny
-- Revision 1.5 2008/08/21 10:55:19 kenny
-- Revision 1.4 2008/08/15 10:29:16 maverick
-- Revision 1.3 2008/08/05 06:35:53 maverick
-- Revision 1.2 2008/08/04 12:47:34 maverick
-- Revision 1.1 2008/07/11 09:36:15 maverick
-- Initial revision
-- Revision 1.7 2008/06/27 16:08:09 maverick
-- Revision 1.6 2008/06/23 08:54:10 kenny
-- Revision 1.5 2008/06/10 13:53:03 maverick
-- Revision 1.4 2008/05/30 14:12:22 maverick
-- Revision 1.3 2008/05/20 02:55:59 maverick
-- Revision 1.2 2008/05/13 02:03:13 maverick
-- Revision 1.6 2008/03/07 07:56:43 kenny
-- Revision 1.5 2007/12/14 10:00:11 niceguy
-- Revision 1.4 2007/12/14 02:42:41 niceguy
-- Revision 1.3 2007/12/06 02:03:04 kenny
-- Revision 1.2 2007/12/03 01:54:35 niceguy
-- Revision 1.1 2007/12/03 01:45:30 niceguy
-- Initial revision
-- Initial revision
E5-120-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises
FROM RFC1155-SMI
OBJECT-TYPE, Counter32, Gauge32, Unsigned32, Counter64, IpAddress, TimeTicks, NOTIFICATION-TYPE
FROM SNMPv2-SMI
DisplayString, PhysAddress, ifIndex
FROM RFC1213-MIB
RowStatus, TEXTUAL-CONVENTION
FROM SNMPv2-TC
VlanIndex, PortList, dot1qVlanIndex
FROM Q-BRIDGE-MIB
dot1dTrafficClass
FROM P-BRIDGE-MIB
MacAddress, Timeout, BridgeId, dot1dBasePort
FROM BRIDGE-MIB
dot1agCfmMdIndex, dot1agCfmMaIndex, dot1agCfmMepIdentifier
FROM IEEE8021-CFMD8-MIB;
calixNetworks OBJECT IDENTIFIER ::= { enterprises 6321 }
calixRegistrations OBJECT IDENTIFIER ::= { calixNetworks 1 }
calixProducts OBJECT IDENTIFIER ::= { calixRegistrations 2 }
e5x100 OBJECT IDENTIFIER ::= { calixProducts 3 }
e5x120 OBJECT IDENTIFIER ::= { e5x100 3 }
alarmconf OBJECT IDENTIFIER ::= { e5x120 2 }
diagnostic OBJECT IDENTIFIER ::= { e5x120 4 }
multicast OBJECT IDENTIFIER ::= { e5x120 7 }
port OBJECT IDENTIFIER ::= { e5x120 8 }
profile OBJECT IDENTIFIER ::= { e5x120 9 }
switch OBJECT IDENTIFIER ::= { e5x120 10 }
sys OBJECT IDENTIFIER ::= { e5x120 11 }
trap OBJECT IDENTIFIER ::= { e5x120 12 }
statistics OBJECT IDENTIFIER ::= { e5x120 13 }
clear OBJECT IDENTIFIER ::= { e5x120 14 }
aesSeriesCommon OBJECT IDENTIFIER ::= { e5x120 97 } -- obsoleted since R2.0 by maverick
iesSeriesCommon OBJECT IDENTIFIER ::= { e5x120 98 }
accessSwitchCommonATM OBJECT IDENTIFIER ::= { e5x120 99 }
----------------------------------------
-- alarmconf
----------------------------------------
alarmOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The manager sets the corresponding bit value to 1 to start the operation
and the agent clears the object to zero when the operation is successfully completed.
The various bit positions are:
BIT 1: clear
BIT 2: cutoff"
::= { alarmconf 1 }
-- Alarm Conf Table
alarmConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes alarm configuration."
::= { alarmconf 2 }
alarmConfEntry OBJECT-TYPE
SYNTAX AlarmConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in alarmConfTable."
INDEX { alarmConfId }
::= { alarmConfTable 1 }
AlarmConfEntry ::=
SEQUENCE {
alarmConfId INTEGER,
alarmConfFacility INTEGER,
alarmConfTarget INTEGER,
alarmConfSeverity INTEGER,
alarmConfClearable INTEGER
}
alarmConfId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
5000:vdslLine_up
5001:vdslLine_down
5002:vdsl_tca_lol
5003:vdsl_tca_lof
5004:vdsl_tca_los
5005:vdsl_tca_lop
5006:vdsl_tca_es
5007:vdsl_tca_ses
5008:vdsl_tca_uas
5009:xd_xtuc_loftrap
5010:xd_xtuc_lostrap
5011:xd_xtur_loftrap
5012:xd_xtur_lostrap
5013:xd_xtur_lprtrap
5014:ad_dhcp_rt_full
5015:ad_dhcp_dm_conflict
5016:ad_dhcp_entry_full
5017:ad_dhcp_ip_dup
5018:ad_dhcp_mac_dup
10000:eqptVol_err
10001:eqptEqpttemp_err
10002:eqptFan_err
10003:eqptHw_rtc_fail
10004:eqptHw_mon_fail
10005:eqptCold_start
10006:eqptWarm_start
10007:eqptAlm_input
10008:eqptAlm_input2
10009:eqptAlm_input3
15000:sysReboot
15001:sysAco
15002:sysAlm_clear
15003:sysLogin_fail
15004:sysAnti_spoofing
15005:sysAlm_svrty_change
15006:sysHost_terminate
20000:enetUp
20001:enetDown
30000:cfmError
"
::= { alarmConfEntry 1 }
alarmConfFacility OBJECT-TYPE
SYNTAX INTEGER {
local1(1),
local2(2),
local3(3),
local4(4),
local5(5),
local6(6),
local7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Alarm facility."
::= { alarmConfEntry 2 }
alarmConfTarget OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination which alarms are reported to. Set the bit to 1 to enable the target.
BIT 1: snmp trap
BIT 2: syslog"
::= { alarmConfEntry 3 }
alarmConfSeverity OBJECT-TYPE
SYNTAX INTEGER {
critical(1),
major(2),
minor(3),
info(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Alarm severity"
::= { alarmConfEntry 4 }
alarmConfClearable OBJECT-TYPE
SYNTAX INTEGER {
clearable(1),
unclearable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the object to one indicates that the alarm is to be cleared when user submits alarm clear."
::= { alarmConfEntry 5 }
-- Alarm Current Table
alarmCurrTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmCurrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes current alarm information."
::= { alarmconf 3 }
alarmCurrEntry OBJECT-TYPE
SYNTAX AlarmCurrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in alarmCurrTable."
INDEX { alarmCurrIndex }
::= { alarmCurrTable 1 }
AlarmCurrEntry ::=
SEQUENCE {
alarmCurrIndex INTEGER,
alarmCurrOccurTime TimeTicks,
alarmCurrTrapOid OBJECT IDENTIFIER,
alarmCurrParam1 INTEGER,
alarmCurrParam2 INTEGER,
alarmCurrParam3 INTEGER,
alarmCurrParam4 INTEGER,
alarmCurrParam5 INTEGER,
alarmCurrParam6 INTEGER,
alarmCurrParam7 INTEGER,
alarmCurrParam8 INTEGER,
alarmCurrTimeDescr DisplayString,
alarmCurrSeverity INTEGER,
alarmCurrDescr DisplayString
}
alarmCurrIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the alarm."
::= { alarmCurrEntry 1 }
alarmCurrOccurTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm occurence time (in hundredths of a second) since the system was last re-initialized."
::= { alarmCurrEntry 2 }
alarmCurrTrapOid OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Trap OID of the alarm."
::= { alarmCurrEntry 3 }
alarmCurrParam1 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 1st parameter of the alarm."
::= { alarmCurrEntry 4 }
alarmCurrParam2 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 2nd parameter of the alarm."
::= { alarmCurrEntry 5 }
alarmCurrParam3 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 3rd parameter of the alarm."
::= { alarmCurrEntry 6 }
alarmCurrParam4 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 4th parameter of the alarm."
::= { alarmCurrEntry 7 }
alarmCurrParam5 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 5th parameter of the alarm."
::= { alarmCurrEntry 8 }
alarmCurrParam6 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 6th parameter of the alarm."
::= { alarmCurrEntry 9 }
alarmCurrParam7 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 7th parameter of the alarm."
::= { alarmCurrEntry 10 }
alarmCurrParam8 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 8th parameter of the alarm."
::= { alarmCurrEntry 11 }
alarmCurrTimeDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The string representation of occurence time (YYYY/MM/DD HH:MM:SS)."
::= { alarmCurrEntry 12 }
alarmCurrSeverity OBJECT-TYPE
SYNTAX INTEGER {
critical(1),
major(2),
minor(3),
info(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity of the alarm."
::= { alarmCurrEntry 13 }
alarmCurrDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of the alarm."
::= { alarmCurrEntry 14 }
-- Alarm Severity Port Table
alarmSeverityPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmSeverityPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes the configuration of alarm reporting severity threshold for each port."
::= { alarmconf 4 }
alarmSeverityPortEntry OBJECT-TYPE
SYNTAX AlarmSeverityPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in alarmSeverityPortTable."
INDEX { ifIndex }
::= { alarmSeverityPortTable 1 }
AlarmSeverityPortEntry ::=
SEQUENCE {
severityThresh INTEGER
}
severityThresh OBJECT-TYPE
SYNTAX INTEGER {
critical(1),
major(2),
minor(3),
info(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The minimum alarm severity that is reported."
::= { alarmSeverityPortEntry 1 }
----------------------------------------
-- diagnostic
----------------------------------------
selt OBJECT IDENTIFIER ::= { diagnostic 3 }
ldm OBJECT IDENTIFIER ::= { diagnostic 4 }
--------------------
-- selt
--------------------
seltTarget OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IfIndex of the port which would be performed single end loopback test."
::= { selt 1 }
seltOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The manager sets the object to 1 to start the selt
and the agent clears the object to zero when selt is successfully completed."
::= { selt 2 }
seltStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status description of the selt result."
::= { selt 3 }
seltCableType OBJECT-TYPE
SYNTAX INTEGER {
awg24(1),
awg26(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cable type that selt result indicates."
::= { selt 4 }
seltLoopEstimateLengthFt OBJECT-TYPE
SYNTAX INTEGER
UNITS "feet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The estimated loop length that selt result indicates."
::= { selt 5 }
seltLoopEstimateLengthMeter OBJECT-TYPE
SYNTAX INTEGER
UNITS "meter"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The estimated loop length that selt result indicates."
::= { selt 6 }
--------------------
-- ldm
--------------------
ldmTarget OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IfIndex of the port which would be performed ldm test."
::= { ldm 1 }
ldmOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The manager sets the object to 1 to start the ldm test
and the agent clears the object to zero when ldm test is successfully completed."
::= { ldm 2 }
ldmStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status description of ldm test result."
::= { ldm 3 }
ldmXtucLoopAttenuation OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop Attenuation."
::= { ldm 4 }
ldmXtucSignalAttenuation OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal Attenuation."
::= { ldm 5 }
ldmXtucSignalMargin OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal Margin."
::= { ldm 6 }
ldmXtucAggregateTxPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual Aggregate Transmit Power."
::= { ldm 7 }
ldmXtucAttainableBitRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "bits per second"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Attainable Bit Rate."
::= { ldm 8 }
ldmXturLoopAttenuation OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop Attenuation."
::= { ldm 9 }
ldmXturSignalAttenuation OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal Attenuation."
::= { ldm 10 }
ldmXturSignalMargin OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal Margin."
::= { ldm 11 }
ldmXturAggregateTxPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual Aggregate Transmit Power."
::= { ldm 12 }
ldmXturAttainableBitRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "bits per second"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Attainable Bit Rate."
::= { ldm 13 }
ldmXtucNumOfSubcarriersPerPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of subcarriers per port for ATU-C."
::= { ldm 14 }
ldmXturNumOfSubcarriersPerPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of subcarriers per port for ATU-R."
::= { ldm 15 }
ldmXtucHlinScale OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Scale of Hlin."
::= { ldm 16 }
ldmXtucHlinReal1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides real part of Hlin for the first 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 17 }
ldmXtucHlinReal2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides real part of Hlin for the last 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 18 }
ldmXtucHlinImage1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides image part of Hlin for the first 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 19 }
ldmXtucHlinImage2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides image part of Hlin for the last 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 20 }
ldmXtucHlog1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Hlog for the first 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 21 }
ldmXtucHlog2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Hlog for the last 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 22 }
ldmXtucQln1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides QLN for the first 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 23 }
ldmXtucQln2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides QLN for the last 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 24 }
ldmXtucSnr1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides SNR for the first 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 25 }
ldmXtucSnr2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides SNR for the last 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 26 }
ldmXturHlinScale OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Scale of Hlin."
::= { ldm 27 }
ldmXturHlinReal OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Real part of Hlin. Each subcarrier takes two octets to store the value."
::= { ldm 28 }
ldmXturHlinImage OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Image part of Hlin. Each subcarrier takes two octets to store the value."
::= { ldm 29 }
ldmXturHlog OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hlog of subcarrier. Each subcarrier takes two octets to store the value."
::= { ldm 30 }
ldmXturQln OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"QLN of subcarrier. Each subcarrier takes two octets to store the value."
::= { ldm 31 }
ldmXturSnr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SNR of subcarrier. Each subcarrier takes two octets to store the value."
::= { ldm 32 }
ldmXtucHlogGroupFactor OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Hlog group factor of ATU-C."
::= { ldm 33 }
ldmXtucQlnGroupFactor OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Qln group factor of ATU-C."
::= { ldm 34 }
ldmXtucSnrGroupFactor OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Snr group factor of ATU-C."
::= { ldm 35 }
ldmXturHlogGroupFactor OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Hlog group factor of ATU-R."
::= { ldm 36 }
ldmXturQlnGroupFactor OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Qln group factor of ATU-R."
::= { ldm 37 }
ldmXturSnrGroupFactor OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Snr group factor of ATU-R."
::= { ldm 38 }
----------------------------------------
-- multicast
----------------------------------------
-- Obsoleted in calix MRD20 since Revision 1.20 at 2009/06/25 by niceguy
-- Object mcastBandwidth, igmpCount below is kept for e5-110 R1.x below. Not used for R2.x and above.
mcastBandwidth OBJECT IDENTIFIER ::= { multicast 4 }
igmpCount OBJECT IDENTIFIER ::= { multicast 5 }
mvlan OBJECT IDENTIFIER ::= { multicast 6 }
queryVid OBJECT IDENTIFIER ::= { multicast 7 }
igmpTimer OBJECT IDENTIFIER ::= { multicast 11 }
auditQuery OBJECT IDENTIFIER ::= { multicast 12 }
igmpProfile OBJECT IDENTIFIER ::= { multicast 13 }
igmpEnable OBJECT-TYPE
SYNTAX INTEGER {
enableProxy(1),
enableSnooping(2),
disable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable IGMP protocol."
::= { multicast 1 }
igmpVersion OBJECT-TYPE
SYNTAX INTEGER {
v2(1),
v3(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting IGMP version."
::= { multicast 9 }
igmpLeaveMode OBJECT-TYPE
SYNTAX INTEGER {
immediateLeave(1),
lastMemberQuery(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure IGMP leave message handling mode."
::= { multicast 10 }
--------------------
-- bandwidth
--------------------
-- removed in calix MRD20
-- To support multiple version of E5-1xx (Currently R1.x and R2.x), we keep all those useful entries in the MIB
mcastDefaultBandwidth OBJECT-TYPE
SYNTAX INTEGER (1..100000)
UNITS "Kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default bandwidth requirement for a multicast channel."
::= { mcastBandwidth 1 }
maxNumOfMcastBw OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of row entries that user can create in mcastBwTable."
::= { mcastBandwidth 2 }
-- mcastBwTable
mcastBwTable OBJECT-TYPE
SYNTAX SEQUENCE OF McastBwEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines bandwidth budget for a range of multicast IP channels."
::= { mcastBandwidth 3 }
mcastBwEntry OBJECT-TYPE
SYNTAX McastBwEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of mcastBwTable."
INDEX { mcastBwIndex, mcastBwStartIp, mcastBwEndIp }
::= { mcastBwTable 1 }
McastBwEntry ::=
SEQUENCE {
mcastBwIndex INTEGER,
mcastBwStartIp IpAddress,
mcastBwEndIp IpAddress,
mcastBwBandwidth INTEGER,
mcastBwRowStatus RowStatus
}
mcastBwIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index which specify the entry."
::= { mcastBwEntry 1 }
mcastBwStartIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The start multicast IP of the bandwidth control range."
::= { mcastBwEntry 2 }
mcastBwEndIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The end multicast IP of the bandwidth control range."
::= { mcastBwEntry 3 }
mcastBwBandwidth OBJECT-TYPE
SYNTAX INTEGER
UNITS "Kbps"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The bandwidth budget for the multicast IP channels."
::= { mcastBwEntry 4 }
mcastBwRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of the entry."
::= { mcastBwEntry 5 }
-- mcastBwPortTable
mcastBwPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF McastBwPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table specify the multicast bandwidth control of the port."
::= { mcastBandwidth 4 }
mcastBwPortEntry OBJECT-TYPE
SYNTAX McastBwPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of mcastBwPortTable."
INDEX { ifIndex }
::= { mcastBwPortTable 1 }
McastBwPortEntry ::=
SEQUENCE {
mcastBwPortEnable INTEGER,
mcastBwPortBandwidth INTEGER
}
mcastBwPortEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable multicast bandwidth control for a port."
::= { mcastBwPortEntry 1 }
mcastBwPortBandwidth OBJECT-TYPE
SYNTAX INTEGER
UNITS "Kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set bandwidth threshold for a port."
::= { mcastBwPortEntry 2 }
--------------------
-- igmpCount
--------------------
-- removed in calix MRD20
-- To support multiple version of E5-1xx (Currently R1.x and R2.x), we keep all those useful entries in the MIB
igmpCountPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpCountPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table specify the IGMP count limiting of the port."
::= { igmpCount 1 }
igmpCountPortEntry OBJECT-TYPE
SYNTAX IgmpCountPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of igmpCountPortTable."
INDEX { ifIndex }
::= { igmpCountPortTable 1 }
IgmpCountPortEntry ::=
SEQUENCE {
igmpCountPortEnable INTEGER,
igmpCountPortLimit INTEGER
}
igmpCountPortEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable IGMP count limiting for a port."
::= { igmpCountPortEntry 1 }
igmpCountPortLimit OBJECT-TYPE
SYNTAX INTEGER (0..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum allowed IGMP report count for a port."
::= { igmpCountPortEntry 2 }
--------------------
-- mvlan
--------------------
maxNumOfMvlan OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of row entries that user can create in mvlanTable."
::= { mvlan 1 }
-- mvlanTable
mvlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF MvlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing static configuration information for
each multicast VLAN configured into the device."
::= { mvlan 2 }
mvlanEntry OBJECT-TYPE
SYNTAX MvlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of mvlanTable."
INDEX { mvlanIndex }
::= { mvlanTable 1 }
MvlanEntry ::=
SEQUENCE {
mvlanIndex VlanIndex,
mvlanName DisplayString,
mvlanEgressPorts PortList,
mvlanUntaggedPorts PortList,
mvlanRowStatus RowStatus
}
mvlanIndex OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VLAN-ID refering to this VLAN."
::= { mvlanEntry 1 }
mvlanName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An administratively assigned string, which may be used to identify the VLAN."
::= { mvlanEntry 2 }
mvlanEgressPorts OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The set of ports which are permanently assigned to the
egress list for this multicast VLAN."
::= { mvlanEntry 3 }
mvlanUntaggedPorts OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The set of ports which should transmit egress packets
for this multicast VLAN as untagged."
::= { mvlanEntry 4 }
mvlanRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the status of this entry."
::= { mvlanEntry 5 }
-- mvlanTranslateTable
mvlanTranslateTable OBJECT-TYPE
SYNTAX SEQUENCE OF MvlanTranslateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains multicast to VLAN translation."
::= { mvlan 3 }
mvlanTranslateEntry OBJECT-TYPE
SYNTAX MvlanTranslateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of mvlanTranslateTable."
INDEX { dot1qVlanIndex, mvlanTranslateIndex }
::= { mvlanTranslateTable 1 }
MvlanTranslateEntry ::=
SEQUENCE {
mvlanTranslateIndex INTEGER,
mvlanTranslateStartIp IpAddress,
mvlanTranslateEndIp IpAddress
}
mvlanTranslateIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index which specif the entry."
::= { mvlanTranslateEntry 1 }
mvlanTranslateStartIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The start IP of the multicast VLAN translation."
::= { mvlanTranslateEntry 2 }
mvlanTranslateEndIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The end IP of the multicast VLAN translation."
::= { mvlanTranslateEntry 3 }
--------------------
-- queryVid
--------------------
maxNumOfQryVid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of row entries that user can create in qryVidConfTable."
::= { queryVid 1 }
-- qryVidConfTable
qryVidConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QryVidConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines statically set VLANs used for response IGMP report."
::= { queryVid 2 }
qryVidConfEntry OBJECT-TYPE
SYNTAX QryVidConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in qryVidConfTable."
INDEX { qryVid }
::= { qryVidConfTable 1 }
QryVidConfEntry ::=
SEQUENCE {
qryVid INTEGER,
qryVidRowStatus RowStatus
}
qryVid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VLAN ID."
::= { qryVidConfEntry 1 }
qryVidRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the status of this entry."
::= { qryVidConfEntry 2 }
-- qryVidStatusTable
qryVidStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF QryVidStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table shows statically set or dynamically learned VLANs used for response IGMP report."
::= { queryVid 3 }
qryVidStatusEntry OBJECT-TYPE
SYNTAX QryVidStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in qryVidStatusTable."
INDEX { qryVid }
::= { qryVidStatusTable 1 }
QryVidStatusEntry ::=
SEQUENCE {
qryVidType INTEGER
}
qryVidType OBJECT-TYPE
SYNTAX INTEGER {
static(1),
dynamic(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VLAN type."
::= { qryVidStatusEntry 1 }
--------------------
-- igmpTimer
--------------------
igmpQryInterval OBJECT-TYPE
SYNTAX INTEGER (10..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set IGMP query interval, 10~1000 in seconds."
::= { igmpTimer 1 }
igmpRobust OBJECT-TYPE
SYNTAX INTEGER (1..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set IGMP query Robustness, 1~5."
::= { igmpTimer 2 }
igmpQryRespInterval OBJECT-TYPE
SYNTAX INTEGER (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set IGMP query response interval, 1~100 in 100 milliseconds."
::= { igmpTimer 3 }
igmpLastMemQryInterval OBJECT-TYPE
SYNTAX INTEGER (1..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set IGMP Last Member Query interval, 1~5 in 100 milliseconds."
::= { igmpTimer 4 }
igmpLastMemQryRobust OBJECT-TYPE
SYNTAX INTEGER (1..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set Last Member Query Robustness, 1~5."
::= { igmpTimer 5 }
--------------------
-- auditQuery
--------------------
auditQryEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable IGMP audit query."
::= { auditQuery 1 }
auditQryInterval OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set IGMP Audit Query Interval, 1~4 in 100 milliseconds."
::= { auditQuery 2 }
auditQryRobust OBJECT-TYPE
SYNTAX INTEGER (1..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set IGMP Audit Query Robustness, 1~5."
::= { auditQuery 3 }
--------------------
-- igmpProfile
--------------------
maxNumberOfIgmpProfiles OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max number of IGMP profiles in the system."
::= { igmpProfile 1 }
igmpProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains IGMP Profiles."
::= { igmpProfile 2 }
igmpProfileEntry OBJECT-TYPE
SYNTAX IgmpProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of IGMP Profile table."
INDEX {IMPLIED igmpProfileName }
::= { igmpProfileTable 1 }
IgmpProfileEntry ::=
SEQUENCE {
igmpProfileName DisplayString,
igmpProfileEnable INTEGER,
igmpProfileMaxGroup INTEGER,
igmpProfileRowStatus RowStatus
}
igmpProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IGMP Profile name."
::= { igmpProfileEntry 1 }
igmpProfileEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable IGMP Profile."
::= { igmpProfileEntry 2 }
igmpProfileMaxGroup OBJECT-TYPE
SYNTAX INTEGER (1..64)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set maximum allowed multicast group, 1~64."
::= { igmpProfileEntry 3 }
igmpProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of the IGMP Profile entry."
::= { igmpProfileEntry 4 }
igmpFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains IGMP Filters."
::= { igmpProfile 3 }
igmpFilterEntry OBJECT-TYPE
SYNTAX IgmpFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of IGMP Filter table."
INDEX { igmpProfileName, igmpFilterIndex }
::= { igmpFilterTable 1 }
IgmpFilterEntry ::=
SEQUENCE {
igmpFilterIndex INTEGER,
igmpFilterStartIp IpAddress,
igmpFilterEndIp IpAddress
}
igmpFilterIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index which specifies the filter rule."
::= { igmpFilterEntry 1 }
igmpFilterStartIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The start IP of the filter rule."
::= { igmpFilterEntry 2 }
igmpFilterEndIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The end IP of the filter rule."
::= { igmpFilterEntry 3 }
igmpProfilePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpProfilePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table specifies the IGMP Profile of the port."
::= { igmpProfile 4 }
igmpProfilePortEntry OBJECT-TYPE
SYNTAX IgmpProfilePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in igmpProfilePortTable."
INDEX { ifIndex }
::= { igmpProfilePortTable 1 }
IgmpProfilePortEntry ::=
SEQUENCE {
igmpProfilePortProfile OCTET STRING
}
igmpProfilePortProfile OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IGMP Profile of the port."
::= { igmpProfilePortEntry 1 }
----------------------------------------
-- port
----------------------------------------
-- Since we define it latter, mark the definition here
-- subrPortTable OBJECT IDENTIFIER ::= { port 1 }
-- adslPort OBJECT IDENTIFIER ::= { port 2 }
vdslPort OBJECT IDENTIFIER ::= { port 3 }
pvc OBJECT IDENTIFIER ::= { port 4 }
-- ppvc OBJECT IDENTIFIER ::= { port 5 }
rpvc OBJECT IDENTIFIER ::= { port 8 }
-- Since we define it latter, mark the definition here
-- dsBcastDisableTable OBJECT IDENTIFIER ::= { port 9 }
paepvc OBJECT IDENTIFIER ::= { port 10 }
tlspvc OBJECT IDENTIFIER ::= { port 11 }
-- ipbpvc OBJECT IDENTIFIER ::= { port 12 }
dtpvc OBJECT IDENTIFIER ::= { port 13 }
snrMgn OBJECT IDENTIFIER ::= { port 15 }
dslRate OBJECT IDENTIFIER ::= { port 16 }
-- G.bond start from 51
gbond OBJECT IDENTIFIER ::= { port 51 }
-- Subscriber Port Table
subrPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF SubrPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes subscriber attributes for the port."
::= { port 1 }
subrPortEntry OBJECT-TYPE
SYNTAX SubrPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in subrPortTable."
INDEX { ifIndex }
::= { subrPortTable 1 }
SubrPortEntry ::=
SEQUENCE {
subrPortName DisplayString,
subrPortTel DisplayString
}
subrPortName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of the subscriber."
::= { subrPortEntry 1 }
subrPortTel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Telephone number of the subscriber."
::= { subrPortEntry 2 }
--------------------
-- adslPort
--------------------
-- ADSL Line Table
-- adslLineConfTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF AdslLineConfEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table includes common attributes describing the ADSL line."
-- ::= { adslPort 1 }
--
-- adslLineConfEntry OBJECT-TYPE
-- SYNTAX AdslLineConfEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry in adslLineConfTable."
-- INDEX { ifIndex }
-- ::= { adslLineConfTable 1 }
--
-- AdslLineConfEntry ::=
-- SEQUENCE {
-- adslLineConfAdslMode INTEGER,
-- adslLineConfAnnexL INTEGER,
-- adslLineConfAnnexM INTEGER,
-- adslLineConfAnnexI INTEGER,
-- adslLineConfOptionMask INTEGER,
-- adslLineConfPowerMgmt INTEGER,
-- adslLineConfPowerMode INTEGER,
-- adslLineConfAturMaxTxPower INTEGER,
-- adslLineConfAtucMaxTxPower INTEGER,
-- adslLineConfMaxRxPower INTEGER,
-- adslLineConfAturCarrierMask OCTET STRING,
-- adslLineConfAtucCarrierMask0 OCTET STRING,
-- adslLineConfAtucCarrierMask1 OCTET STRING,
-- adslLineConfAturInp INTEGER,
-- adslLineConfAtucInp INTEGER,
-- adslLineConfL0Time INTEGER,
-- adslLineConfL2Time INTEGER,
-- adslLineConfL2ATPR INTEGER,
-- adslLineConfL2ATPRT INTEGER,
-- adslLineConfMaxL2Rate INTEGER,
-- adslLineConfMinL2Rate INTEGER,
-- adslLineConfL0toL2Rate INTEGER
-- }
--
-- adslLineConfAdslMode OBJECT-TYPE
-- SYNTAX INTEGER {
-- gDotLite(1),
-- gDotDmt(2),
-- t1Dot413(3),
-- auto(4),
-- etsi(5),
-- adsl2(6),
-- adsl2Plus(7)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "G.lite and T1.413 are only applicable to annex A board.
-- ETSI is only applicable to annex B board."
-- ::= { adslLineConfEntry 1 }
--
-- adslLineConfAnnexL OBJECT-TYPE
-- SYNTAX INTEGER {
-- enableNarrowMode(1),
-- enableWideMode(2),
-- disable(3)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Enable/disable annex L for the port(Only in AnnexA)."
-- ::= { adslLineConfEntry 2 }
--
-- adslLineConfAnnexM OBJECT-TYPE
-- SYNTAX INTEGER {
-- enable(1),
-- disable(2)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Enable/disable annex M for the port(For BCM AnnexA solution)."
-- ::= { adslLineConfEntry 3 }
--
-- adslLineConfAnnexI OBJECT-TYPE
-- SYNTAX INTEGER {
-- enable(1),
-- disable(2)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Enable/disable annex I for the port(For BCM AnnexA solution)."
-- ::= { adslLineConfEntry 4 }
--
-- adslLineConfOptionMask OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The semantic for each bit is:
-- BIT 1 : Disable Trellis
-- BIT 2 : Disable Reed-Solomon
-- BIT 3 : Disable upstream bitswap
-- BIT 4 : Disable downstream bitswap
-- BIT 5 : Disable 1-bit constellation
-- BIT 6 : Disable transmit windowing
-- BIT 7 : Disable s=0.5 support (ADSL1 only)
-- BIT 8 : Disable G.lite rate limit (ADSL1 only)"
-- ::= { adslLineConfEntry 5 }
--
-- adslLineConfPowerMgmt OBJECT-TYPE
-- SYNTAX INTEGER {
-- enableL2(1),
-- enableL2(2),
-- disable(3)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Enable/disable power management for the port."
-- ::= { adslLineConfEntry 6 }
--
-- adslLineConfPowerMode OBJECT-TYPE
-- SYNTAX INTEGER {
-- fix(1),
-- priorityToPower(2),
-- priorityToRate(3)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The power mode of the ADSL line."
-- ::= { adslLineConfEntry 7 }
--
-- adslLineConfAturMaxTxPower OBJECT-TYPE
-- SYNTAX INTEGER (-130..200)
-- UNITS "tenth dBm"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The maximum allowed transmit power of ATU-R."
-- ::= { adslLineConfEntry 8 }
--
-- adslLineConfAtucMaxTxPower OBJECT-TYPE
-- SYNTAX INTEGER (-50..200)
-- UNITS "tenth dBm"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The maximum allowed transmit power of ATU-C."
-- ::= { adslLineConfEntry 9 }
--
-- adslLineConfMaxRxPower OBJECT-TYPE
-- SYNTAX INTEGER (-255..255)
-- UNITS "tenth dBm"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The maximum aggregate received power."
-- ::= { adslLineConfEntry 10 }
--
-- adslLineConfAturCarrierMask OBJECT-TYPE
-- SYNTAX OCTET STRING
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The upstream carrier mask. For CTLM AnnexA solution, bin is from 0 to 31;
-- CTLM AnnexB solution, bin is from 0 to 63; BCM solution, bin is from 0 to 63.
-- Bit set to 1 indicates the bin is masked off."
-- ::= { adslLineConfEntry 11 }
--
-- adslLineConfAtucCarrierMask0 OBJECT-TYPE
-- SYNTAX OCTET STRING
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The downstream carrier mask. For CTLM AnnexA solution, bin is from 32 to 255;
-- CTLM AnnexB solution, bin is from 64 to 255; BCM solution, bin is from 32 to 255.
-- Bit set to 1 indicates the bin is masked off."
-- ::= { adslLineConfEntry 12 }
--
-- adslLineConfAtucCarrierMask1 OBJECT-TYPE
-- SYNTAX OCTET STRING
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The downstream carrier mask from bin 256 to 511. Bit set to 1 indicates
-- the bin is masked off."
-- ::= { adslLineConfEntry 13 }
--
-- adslLineConfAturInp OBJECT-TYPE
-- SYNTAX INTEGER {
-- zero(1),
-- zero_point_five(2),
-- one(3),
-- two(4),
-- four(5),
-- eight(6),
-- sixteen(7)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The upstream Impulse Noise Protection minimum setting in unit of DMT symbol.
-- For CTLM solution, user can set value from 1 ~ 4,
-- but for BCM solution, user can set value from 1 ~ 7."
-- ::= { adslLineConfEntry 14 }
--
-- adslLineConfAtucInp OBJECT-TYPE
-- SYNTAX INTEGER {
-- zero(1),
-- zero_point_five(2),
-- one(3),
-- two(4),
-- four(5),
-- eight(6),
-- sixteen(7)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The downstream Impulse Noise Protection minimum setting in unit of DMT symbol.
-- For CTLM solution, user can set value from 1 ~ 4,
-- but for BCM solution, user can set value from 1 ~ 7."
-- ::= { adslLineConfEntry 15 }
--
--
-- adslLineConfL0Time OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Set the minimum time in seconds that the ADSL line
-- must stay in L0 power mode before changing to the L2 power mode.
-- For CTLM solution, the range is 120 ~ 65535;
-- for BCM solution, the range is 10 ~ 65535."
-- ::= { adslLineConfEntry 16 }
--
-- adslLineConfL2Time OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Set minimum time in seconds that the ADSL line must stay in the
-- L2 power mode before reducing the power again in the L2 power mode.
-- For CTLM solution, the range is 60 ~ 65535;
-- for BCM solution, the range is 10 ~ 65535."
-- ::= { adslLineConfEntry 17 }
--
-- adslLineConfL2ATPR OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "dB"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Set the maximum Aggregate Transmit Power Reduction (ATPR)
-- in decibels (dB) that is permitted in a L2 power reduction.
-- The system can gradually decrease the ADSL line transmission power
-- while it is in the L2 power mode. This is the largest individual
-- power reduction allowed in the L2 power mode.
-- For CTLM solution, the range is 1 ~ 5(dB);
-- for BCM solution, the range is 0 ~ 15(dB)."
-- ::= { adslLineConfEntry 18 }
--
-- adslLineConfL2ATPRT OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "dB"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "the maximum Aggregate Transmit Power Reduction Total (ATPRT)
-- in decibels (dB) that is permitted in the L2 power mode.
-- This is the total transmit power decrease that is allowed
-- to occur in the L2 power mode.
-- For CTLM solution, the range is 1 ~ 40(dB);
-- for BCM solution, the range is 0 ~ 15(dB)."
-- ::= { adslLineConfEntry 19 }
--
--
-- adslLineConfMaxL2Rate OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "kbps"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "configured maximum L2 rate.
-- (32~4096 Kbps, 4 Kbps resolution. For CTLM solution, 0 for system assign; for BCM solution, default:4096.)"
-- ::= { adslLineConfEntry 20 }
--
-- adslLineConfMinL2Rate OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "kbps"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "configured minimum L2 rate.
-- (32~4096 Kbps, 4 Kbps resolution, For CTLM solution, 0 for system assign; for BCM solution, default:32.)"
-- ::= { adslLineConfEntry 21 }
--
-- adslLineConfL0toL2Rate OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "kbps"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "configured transition L0 to L2 rate.
-- (<=min_l2rate/2 and >= 16 Kbps, For CTLM solution, 0 for system assign; for BCM solution, default:16.)"
-- ::= { adslLineConfEntry 22 }
--
-- ADSL Port Batch Set
--
-- adslPortBatchSet OBJECT IDENTIFIER ::= { adslPort 3 }
--
-- adslPortTarget OBJECT-TYPE
-- SYNTAX OCTET STRING
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The managed object is used for identify the target on which
-- the port configuration should be performed. The target is encoded as:
-- Byte 1: 0, Reserved(chaises)
-- Byte 2~3: 0,0 Reserved(slot)
-- Byte 4: 0, reserved
-- Byte 5~11:each octet specifies a set of eight ports, with the first
-- octet specifying ports 1 through 8, etc."
-- ::= { adslPortBatchSet 1 }
--
-- adslPortOps OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The managed object is for ADSL line configuration. When the EMS
-- wants to issue the desired operation, the EMS shall send SNMP-SET message to set
-- the corresponding bit value to be 1. The various bit positions are:
-- BIT 1: enable port
-- BIT 2: disable port
-- BIT 3: set ADSL mode
-- BIT 4: set line profile
-- BIT 5: set alarm profile
-- BIT 6: enable Annex L to be narrow mode(Only in AnnexA)
-- BIT 7: enable Annex L to be wide mode(Only in AnnexA)
-- BIT 8: disable Annex L(Only in AnnexA)
-- BIT 9: enable Annex M (For BCM AnnexA solution)
-- BIT 10: disable Annex M (For BCM AnnexA solution)
-- BIT 11: enable Annex I (For BCM AnnexA solution)
-- BIT 12: disable Annex I (For BCM AnnexA solution)
-- BIT 13: set option mask
-- BIT 14: enable power management mode to be L2
-- BIT 15: enable power management mode to be L2
-- BIT 16: disable power management mode
-- BIT 17: set power mode to be fixed
-- BIT 18: set power mode to be priority to power
-- BIT 19: set power mode to be priority to rate
-- BIT 20: set ATU-R max Tx power
-- BIT 21: set ATU-C max Tx power
-- BIT 22: set max Rx power
-- BIT 23: set ATU-R carrier mask
-- BIT 24: set ATU-C carrier mask
-- BIT 25: set ATU-R INP minimum setting
-- BIT 26: set ATU-C INP minimum setting"
-- ::= { adslPortBatchSet 2 }
--
-- adslPortOps2 OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The managed object is for ADSL line configuration. When the EMS
-- wants to issue the desired operation, the EMS shall send SNMP-SET message to set
-- the corresponding bit value to be 1. The various bit positions are:
-- BIT 1: set L0 Time
-- BIT 2: set L2 Time
-- BIT 3: set L2 ATPR
-- BIT 4: set L2 ATPRT
-- BIT 5: set maximum L2 rate
-- BIT 6: set minimum L2 rate
-- BIT 7: set transition L0 to L2 rate"
-- ::= { adslPortBatchSet 3 }
--
--
-- adslModeForBatchSet OBJECT-TYPE
-- SYNTAX INTEGER {
-- gDotLite(1),
-- gDotDmt(2),
-- t1Dot413(3),
-- auto(4),
-- etsi(5),
-- adsl2(6),
-- adsl2Plus(7)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "G.lite and T1.413 are only applicable to annex A board.
-- ETSI is only applicable to annex B board."
-- ::= { adslPortBatchSet 4 }
--
-- adslLineProfileForBatchSet OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (1..31))
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The ADSL line profile."
-- ::= { adslPortBatchSet 5 }
--
-- adslAlarmProfileForBatchSet OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (1..31))
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The ADSL alarm profile."
-- ::= { adslPortBatchSet 6 }
--
-- adslOptionMaskForBatchSet OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The semantic for each bit is identical to the object adslLineConfOptionMask."
-- ::= { adslPortBatchSet 7 }
--
-- adslAturMaxTxPowerForBatchSet OBJECT-TYPE
-- SYNTAX INTEGER (-130..200)
-- UNITS "tenth dBm"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The maximum allowed transmit power of ATU-R."
-- ::= { adslPortBatchSet 8 }
--
-- adslAtucMaxTxPowerForBatchSet OBJECT-TYPE
-- SYNTAX INTEGER (-50..200)
-- UNITS "tenth dBm"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The maximum allowed transmit power of ATU-C."
-- ::= { adslPortBatchSet 9 }
--
-- adslMaxRxPowerForBatchSet OBJECT-TYPE
-- SYNTAX INTEGER (-255..255)
-- UNITS "tenth dBm"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The maximum aggregate received power."
-- ::= { adslPortBatchSet 10 }
--
-- adslAturCarrierMaskForBatchSet OBJECT-TYPE
-- SYNTAX OCTET STRING
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The upstream carrier mask.For CTLM AnnexA solution, bin is from 0 to 31;
-- CTLM AnnexB solution, bin is from 0 to 63; BCM solution, bin is from 0 to 63.
-- Bit set to 1 indicates the bin is masked off."
-- ::= { adslPortBatchSet 11 }
--
-- adslAtucCarrierMask0ForBatchSet OBJECT-TYPE
-- SYNTAX OCTET STRING
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The downstream carrier mask from bin 32 to 255. Bit set to 1 indicates
-- the bin is masked off."
-- ::= { adslPortBatchSet 12 }
--
-- adslAtucCarrierMask1ForBatchSet OBJECT-TYPE
-- SYNTAX OCTET STRING
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The downstream carrier mask from bin 256 to 511. Bit set to 1 indicates
-- the bin is masked off."
-- ::= { adslPortBatchSet 13 }
--
-- adslAturInpForBatchSet OBJECT-TYPE
-- SYNTAX INTEGER {
-- zero(1),
-- zero_point_five(2),
-- one(3),
-- two(4),
-- four(5),
-- eight(6),
-- sixteen(7)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The upstream Impulse Noise Protection minimum setting in unit of DMT symbol.
-- For CTLM solution, user can set value from 1 ~ 4, but for BCM solution, user can set value from 1 ~ 7."
-- ::= { adslPortBatchSet 14 }
--
-- adslAtucInpForBatchSet OBJECT-TYPE
-- SYNTAX INTEGER {
-- zero(1),
-- zero_point_five(2),
-- one(3),
-- two(4),
-- four(5),
-- eight(6),
-- sixteen(7)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The downstream Impulse Noise Protection minimum setting in unit of DMT symbol.
-- For CTLM solution, user can set value from 1 ~ 4, but for BCM solution, user can set value from 1 ~ 7."
-- ::= { adslPortBatchSet 15 }
--
--
-- adslL0TimeForBatchSet OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Set the minimum time in seconds that the ADSL line
-- must stay in L0 power mode before changing to the L2 power mode.
-- For CTLM solution, the range is 120 ~ 65535; for BCM solution, the range is 10 ~ 65535."
-- ::= { adslPortBatchSet 16 }
--
-- adslL2TimeForBatchSet OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Set minimum time in seconds that the ADSL line
-- must stay in the L2 power mode before reducing the power
-- again in the L2 power mode.
-- For CTLM solution, the range is 60 ~ 65535; for BCM solution, the range is 10 ~ 65535."
-- ::= { adslPortBatchSet 17 }
--
-- adslL2ATPRForBatchSet OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "dB"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Set the maximum Aggregate Transmit Power Reduction (ATPR)
-- in decibels (dB) that is permitted in a L2 power reduction.
-- The system can gradually decrease the ADSL line transmission power
-- while it is in the L2 power mode. This is the largest individual
-- power reduction allowed in the L2 power mode.
-- For CTLM solution, the range is 1 ~ 5(dB); for BCM solution, the range is 0 ~ 15(dB)."
-- ::= { adslPortBatchSet 18 }
--
-- adslL2ATPRTForBatchSet OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "dB"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "the maximum Aggregate Transmit Power Reduction Total (ATPRT)
-- in decibels (dB) that is permitted in the L2 power mode.
-- This is the total transmit power decrease that is allowed
-- to occur in the L2 power mode.
-- For CTLM solution, the range is 1 ~ 40(dB); for BCM solution, the range is 0 ~ 15(dB)."
-- ::= { adslPortBatchSet 19 }
--
-- adslMaxL2RateForBatchSet OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "kbps"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "configured maximum L2 rate.
-- (32~4096 Kbps, 4 Kbps resolution. For CTLM solution, 0 for system assign; for BCM solution, default:4096.)"
-- ::= { adslPortBatchSet 20 }
--
-- adslMinL2RateForBatchSet OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "kbps"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "configured minimum L2 rate.
-- (32~4096 Kbps, 4 Kbps resolution, For CTLM solution, 0 for system assign; for BCM solution, default:32.)"
-- ::= { adslPortBatchSet 21 }
--
-- adslL0toL2RateForBatchSet OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "kbps"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "configured transition L0 to L2 rate.
-- (<=min_l2rate/2 and >= 16 Kbps, For CTLM solution, 0 for system assign; for BCM solution, default:16.)"
-- ::= { adslPortBatchSet 22 }
--
-- Line Status
--
-- adslLineStatusTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF AdslLineStatusEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table includes the ADSL line status."
-- ::= { adslPort 4 }
--
-- adslLineStatusEntry OBJECT-TYPE
-- SYNTAX AdslLineStatusEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry in adslLineStatusTable."
-- INDEX { ifIndex }
-- ::= { adslLineStatusTable 1 }
--
-- AdslLineStatusEntry ::=
-- SEQUENCE {
-- adslLineStatusMode INTEGER,
-- adslLineUpTime INTEGER
-- }
--
-- adslLineStatusMode OBJECT-TYPE
-- SYNTAX INTEGER {
-- gDotLite(1),
-- gDotDmt(2),
-- t1Dot413(3),
-- etsi(4),
-- adsl2(5),
-- adsl2Plus(6),
-- none(7)
-- }
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The link up mode of the ADSL line."
-- ::= { adslLineStatusEntry 1 }
--
-- adslLineUpTime OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The link up time of the ADSL line, in unit of seconds"
-- ::= { adslLineStatusEntry 2 }
--
-- Power Mgmt Parameter Table
--
-- powerMgmtParamTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF PowerMgmtParamEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table defines L0 to L2 power transition parameters."
-- ::= { adslPort 5 }
--
-- powerMgmtParamEntry OBJECT-TYPE
-- SYNTAX PowerMgmtParamEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry in powerMgmtParamTable."
-- INDEX { ifIndex }
-- ::= { powerMgmtParamTable 1 }
--
-- PowerMgmtParamEntry ::=
-- SEQUENCE {
-- powerMgmtL0Time INTEGER,
-- powerMgmtL2Time INTEGER,
-- powerMgmtL2Atpr INTEGER,
-- powerMgmtL2Atprt INTEGER,
-- powerMgmtL2MinRate INTEGER,
-- powerMgmtL2MaxRate INTEGER,
-- powerMgmtL2ThreshRate INTEGER
-- }
--
-- powerMgmtL0Time OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "second"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The object specifies the minimum time in L0 mode before L2 mode may be entered."
-- ::= { powerMgmtParamEntry 1 }
--
-- powerMgmtL2Time OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "second"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The object specifies the minimum time in L2 mode before trimming and in between power trims."
-- ::= { powerMgmtParamEntry 2 }
--
-- powerMgmtL2Atpr OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "dB"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The maximum Aggregate Transmit Power Reduction."
-- ::= { powerMgmtParamEntry 3 }
--
-- powerMgmtL2Atprt OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "dB"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The maximum Aggregate Transmit Power Reduction Total."
-- ::= { powerMgmtParamEntry 4 }
--
-- powerMgmtL2MinRate OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "Kbps"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The object specifies the minimum L2 rate."
-- ::= { powerMgmtParamEntry 5 }
--
-- powerMgmtL2MaxRate OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "Kbps"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The object specifies the maximum L2 rate."
-- ::= { powerMgmtParamEntry 6 }
--
-- powerMgmtL2ThreshRate OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "Kbps"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The object specifies the rate threshold that triggers the line entering L0 or L2 mode."
-- ::= { powerMgmtParamEntry 7 }
--
-- Power Mgmt PSD Table
-- Not support in 7324 RU R4.0.2
-- powerMgmtPSDTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF PowerMgmtPSDEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table provides the PSD setting for both ATU-C and ATU-R."
-- ::= { adslPort 6 }
--
-- powerMgmtPSDEntry OBJECT-TYPE
-- SYNTAX PowerMgmtPSDEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry in powerMgmtPSDTable."
-- INDEX { ifIndex }
-- ::= { powerMgmtPSDTable 1 }
--
-- PowerMgmtPSDEntry ::=
-- SEQUENCE {
-- powerMgmtAtucMaxPSD INTEGER,
-- powerMgmtAturMaxPSD INTEGER
-- }
--
-- powerMgmtAtucMaxPSD OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "0.1dBm/Hz"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The object specifies the maximum ATU-C PSD."
-- ::= { powerMgmtPSDEntry 1 }
--
-- powerMgmtAturMaxPSD OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "0.1dBm/Hz"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The object specifies the maximum ATU-R PSD."
-- ::= { powerMgmtPSDEntry 2 }
--------------------
-- vdslPort
--------------------
-- VDSL Line Table
vdslLineConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF VdslLineConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes common attributes describing the VDSL line.
This table is supported by R2.00 and later versions."
::= { vdslPort 1 }
vdslLineConfEntry OBJECT-TYPE
SYNTAX VdslLineConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in vdslLineConfTable."
INDEX { ifIndex }
::= { vdslLineConfTable 1 }
VdslLineConfEntry ::=
SEQUENCE {
vdslLineConfUpbo INTEGER,
vdslLineConfVdslProfile INTEGER,
-- vdslLineConfFrequencyPlan INTEGER,
vdslLineConfRfiBand INTEGER,
vdslLineConfIpqosProfile DisplayString,
vdslLineConfVturInp INTEGER,
vdslLineConfVtucInp INTEGER,
vdslLineConfOptionMask INTEGER,
vdslLineConfUpboForceLength INTEGER,
vdslLineConfPsdShape INTEGER,
vdslLineConfDpbo INTEGER,
vdslLineConfDpboParamEsel INTEGER,
vdslLineConfDpboParamEscma INTEGER,
vdslLineConfDpboParamEscmb INTEGER,
vdslLineConfDpboParamEscmc INTEGER,
vdslLineConfDpboParamMus INTEGER,
vdslLineConfDpboParamFmin INTEGER,
vdslLineConfDpboParamFmax INTEGER,
vdslLineConfDpboParamPsdId INTEGER
-- vdslLineConfPMask INTEGER
}
vdslLineConfUpbo OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable upstream power backoff control."
::= { vdslLineConfEntry 1 }
vdslLineConfVdslProfile OBJECT-TYPE
SYNTAX INTEGER {
vdsl8a(1),
vdsl8b(2),
vdsl8c(3),
vdsl8d(4),
vdsl12a(5),
vdsl12b(6),
vdsl17a(7),
auto(8),
adsl2plus(9),
vdsl2(10),
gdmt(11),
glite(12),
adsl2(13),
t1413(14),
vdsl2adsl2(15),
vdsl2gdmt(16),
vdsl2glite(17),
vdsl2t1413(18)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set VDSL profile."
::= { vdslLineConfEntry 2 }
-- vdslLineConfFrequencyPlan OBJECT-TYPE
-- SYNTAX INTEGER {
-- plan997(1),
-- plan998(2)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Set VDSL frequency plan."
-- ::= { vdslLineConfEntry 3 }
vdslLineConfRfiBand OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
ansi(2),
etsi(3),
custom(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set VDSL customized RFI configuration.
disable: not apply RFI notch to port
ansi: use pre-defined ANSI RFI notch
etsi: use pre-defined ETSI notch
custom: user needs to define customized RFI notch band through vdslRfiCustomTable"
::= { vdslLineConfEntry 4 }
vdslLineConfIpqosProfile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { vdslLineConfEntry 5 }
vdslLineConfVturInp OBJECT-TYPE
SYNTAX INTEGER (0..160)
UNITS "0.1 DTM symbol"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VTUR minimum INP value"
::= { vdslLineConfEntry 6 }
vdslLineConfVtucInp OBJECT-TYPE
SYNTAX INTEGER (0..160)
UNITS "0.1 DTM symbol"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VTUC mimimum INT value"
::= { vdslLineConfEntry 7 }
vdslLineConfOptionMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Bit1: disable Trellis coding in ADSL mode
Bit2: disable Reed-Solomon coding for ADSL
Bit3: disable upstream bitswaps
Bit4: disable downstream bitwaps
Bit5: disable upstream 1-bit constellation support
Bit6: disable the transmit windowing in ADSL2+ mode
Bit7: disable S=0.5 support in G.dmt
Bit8: reserved
Bit9: enable nitro
Bit10: enable ADSL2 Annex L
Bit11: enable ADSL2+ Annex M
Bit12: enable US PTM optimization
Bit13: enable DS PTM optimization
Bit14: enable US PHYR
Bit15: enable DS PHYR"
::= { vdslLineConfEntry 8 }
vdslLineConfUpboForceLength OBJECT-TYPE
SYNTAX INTEGER (-5..1270)
UNITS "0.1dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"-1 means max(kl0_CO,kl0_CPE).
-2 means min(kl0_CO,kl0_CPE).
-3 means kl0_CO.
-4 means kl0_CPE.
-5 means kl0_CPE + delta as calculated from.
"
::= { vdslLineConfEntry 9 }
vdslLineConfPsdShape OBJECT-TYPE
SYNTAX INTEGER {
vdsl2aNus0(1),
vdsl2aEu32(2),
vdsl2aEu36(3),
vdsl2aEu40(4),
vdsl2aEu44(5),
vdsl2aEu48(6),
vdsl2aEu52(7),
vdsl2aEu56(8),
vdsl2aEu60(9),
vdsl2aEu64(10),
vdsl2aEu128(11),
vdsl1fttexAnsiM1(12),
vdsl1fttexAnsiM2(13),
vdsl1fttcabAnsiM1(14),
vdsl1fttcabAnsiM2(15),
vdsl1fttexAnsiM1E(16),
vdsl1fttexAnsiM2E(17),
vdslFttcabAnsiM1E(18),
vdslFttcabAnsiM2E(19),
vdsl2aCt(20),
vdsl2b8x1(21),
vdsl2b8x2(22),
vdsl2b8x3(23),
vdsl2b8x4(24),
vdsl2b8x5(25),
vdsl2b8x6(26),
vdsl2b8x7(27),
vdsl2b8x8(28),
vdsl2b8x9(29),
vdsl2b8x10(30),
vdsl2b8x11(31),
vdsl2b8x12(32),
vdsl2b8x13(33),
vdsl2b8x14(34),
vdsl2b8x15(35),
vdsl2b8x16(36),
vdsl2b7x1(37),
vdsl2b7x2(38),
vdsl2b7x3(39),
vdsl2b7x4(40),
vdsl2b7x5(41),
vdsl2b7x6(42),
vdsl2b7x7(43),
vdsl2b7x8(44),
vdsl2b7x9(45),
vdsl2b7x10(46),
vdsl2btAnfp(47),
vdsl2c138b(48),
vdsl2c276b(49),
vdsl2c138co(50),
vdsl2c276co(51),
vdsl2cTcmisdn(52),
vdsl1QAMCompatible(53)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"PSD mask type"
::= { vdslLineConfEntry 10 }
vdslLineConfDpbo OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable DPBO"
::= { vdslLineConfEntry 11 }
vdslLineConfDpboParamEsel OBJECT-TYPE
SYNTAX INTEGER (0..511)
UNITS "0.5dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DPBO ESEL parameter"
::= { vdslLineConfEntry 12 }
vdslLineConfDpboParamEscma OBJECT-TYPE
SYNTAX INTEGER (0..640)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DPBO ESCMA parameter -1~1.5 in step of 1/256."
::= { vdslLineConfEntry 13 }
vdslLineConfDpboParamEscmb OBJECT-TYPE
SYNTAX INTEGER (0..640)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DPBO ESCMB parameter -1~1.5 in step of 1/256."
::= { vdslLineConfEntry 14 }
vdslLineConfDpboParamEscmc OBJECT-TYPE
SYNTAX INTEGER (0..640)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DPBO ESCMC parameter -1~1.5 in step of 1/256."
::= { vdslLineConfEntry 15 }
vdslLineConfDpboParamMus OBJECT-TYPE
SYNTAX INTEGER (0..255)
UNITS "-0.5 dBm/Hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DPBO MUS parameter."
::= { vdslLineConfEntry 16 }
vdslLineConfDpboParamFmin OBJECT-TYPE
SYNTAX INTEGER (0..2048)
UNITS "4.3125kHz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DPBO FMIN parameter"
::= { vdslLineConfEntry 17 }
vdslLineConfDpboParamFmax OBJECT-TYPE
SYNTAX INTEGER (32..6956)
UNITS "4.3125kHz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DPBO FMAX parameter"
::= { vdslLineConfEntry 18 }
vdslLineConfDpboParamPsdId OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
psdCo(1),
psdFlat(2),
psdCabAnsi(3),
psdCabEtsi(4),
psdExchEtsi(5),
psdExchAnsi(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Valid range for setting is 1~6."
::= { vdslLineConfEntry 19 }
-- vdslLineConfPMask OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "
-- Bit1: G.DMT (G.992.1)
-- Bit2: G.LITE (G.992.2)
-- Bit3: ADSL2 (G.992.3)
-- Bit5: ADSL2+ (G.992.5)
-- Bit6: ANSI T1.413
-- Bit8: G.993.2 VDSL profile 8a
-- Bit9: G.993.2 VDSL profile 8b
-- Bit10: G.993.2 VDSL profile 8c
-- Bit11: G.993.2 VDSL profile 8d
-- Bit12: G.993.2 VDSL profile 12a
-- Bit13: G.993.2 VDSL profile 12b
-- Bit14: G.993.2 VDSL profile 17a"
-- ::= { vdslLineConfEntry 20 }
vdslVlan OBJECT IDENTIFIER ::= { vdslPort 2 }
-- vdslPortConfTable
vdslPortConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF VdslPortConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes common attributes describing the VDSL port.
This table is supported by R2.00 and later versions."
::= { vdslVlan 1 }
vdslPortConfEntry OBJECT-TYPE
SYNTAX VdslPortConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in vdslPortConfTable."
INDEX { ifIndex }
::= { vdslPortConfTable 1 }
VdslPortConfEntry ::=
SEQUENCE {
-- vdslPortConfPvid VlanIndex,
-- vdslPortConfPriority INTEGER,
-- vdslPortConfAcceptableFrameType INTEGER,
vdslPortConfTlsEnable INTEGER,
vdslPortConfTlsVid VlanIndex,
vdslPortConfTlsPriority INTEGER,
vdslPortConfDtEnable INTEGER,
vdslPortConfDtSVid VlanIndex,
vdslPortConfDtSPriority INTEGER,
vdslPortConfDtCVid VlanIndex,
vdslPortConfDtCPriority INTEGER
}
-- vdslPortConfPvid OBJECT-TYPE
-- SYNTAX VlanIndex
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The PVID, the VLAN ID assigned to untagged frames or
-- Priority-Tagged frames received on this port."
-- ::= { vdslPortConfEntry 1 }
--
-- vdslPortConfPriority OBJECT-TYPE
-- SYNTAX INTEGER (0..7)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The default ingress User Priority for this port."
-- ::= { vdslPortConfEntry 2 }
--
-- vdslPortConfAcceptableFrameType OBJECT-TYPE
-- SYNTAX INTEGER {
-- admitAll(1),
-- admitOnlyVlanTagged(2)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "When this is admitOnlyVlanTagged(2) the device will
-- discard untagged frames or Priority-Tagged frames
-- received on this port. When admitAll(1), untagged
-- frames or Priority-Tagged frames received on this port
-- will be accepted and assigned to the PVID for this port"
-- ::= { vdslPortConfEntry 3 }
vdslPortConfTlsEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable the transparent LAN service."
::= { vdslPortConfEntry 4 }
vdslPortConfTlsVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The transparent LAN service s-tag VID."
::= { vdslPortConfEntry 5 }
vdslPortConfTlsPriority OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The transparent LAN service s-tag priority."
::= { vdslPortConfEntry 6 }
vdslPortConfDtEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable the Double Tagging service."
::= { vdslPortConfEntry 7 }
vdslPortConfDtSVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Double Tagging service s-tag VID."
::= { vdslPortConfEntry 8 }
vdslPortConfDtSPriority OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Double Tagging service s-tag priority."
::= { vdslPortConfEntry 9 }
vdslPortConfDtCVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Double Tagging service c-tag VID."
::= { vdslPortConfEntry 10 }
vdslPortConfDtCPriority OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Double Tagging service c-tag priority."
::= { vdslPortConfEntry 11 }
-- vdslPortVlanTranslateTable
vdslPortVlanTranslateTable OBJECT-TYPE
SYNTAX SEQUENCE OF VdslPortVlanTranslateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains VLAN translation."
::= { vdslVlan 2 }
vdslPortVlanTranslateEntry OBJECT-TYPE
SYNTAX VdslPortVlanTranslateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in vdslPortVlanTranslateTable."
INDEX { ifIndex , vdslPortVlanTranslateVpi , vdslPortVlanTranslateVci , vdslPortVlanTranslateCvid }
::= { vdslPortVlanTranslateTable 1 }
VdslPortVlanTranslateEntry ::=
SEQUENCE {
vdslPortVlanTranslateVpi INTEGER,
vdslPortVlanTranslateVci INTEGER,
vdslPortVlanTranslateCxvid VlanIndex,
vdslPortVlanTranslateCvid VlanIndex,
vdslPortVlanTranslateSvid VlanIndex,
vdslPortVlanTranslateDsonly INTEGER,
vdslPortVlanTranslateRowStatus RowStatus
}
vdslPortVlanTranslateVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI of the vtt."
::= { vdslPortVlanTranslateEntry 1 }
vdslPortVlanTranslateVci OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI of the vtt."
::= { vdslPortVlanTranslateEntry 2 }
vdslPortVlanTranslateCxvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CXVID of the vtt."
::= { vdslPortVlanTranslateEntry 3 }
vdslPortVlanTranslateCvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CVID of the vtt."
::= { vdslPortVlanTranslateEntry 4 }
vdslPortVlanTranslateSvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SVID of the vtt."
::= { vdslPortVlanTranslateEntry 5 }
vdslPortVlanTranslateDsonly OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Donwstream direction only of the vtt."
::= { vdslPortVlanTranslateEntry 6 }
vdslPortVlanTranslateRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in this table."
::= { vdslPortVlanTranslateEntry 7 }
-- vdslPortVlanTable
-- vdslPortVlanTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF VdslPortVlanEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table includes common attributes describing the VDSL port.
-- This table is supported by R2.00 and later versions."
-- ::= { vdslVlan 2 }
--
-- vdslPortVlanEntry OBJECT-TYPE
-- SYNTAX VdslPortVlanEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry in vdslPortVlanTable."
-- INDEX { ifIndex, dot1qVlanIndex }
-- ::= { vdslPortVlanTable 1 }
--
-- VdslPortVlanEntry ::=
-- SEQUENCE {
-- vdslPortVlanReg INTEGER,
-- vdslPortVlanTag INTEGER,
-- vdslPortVlanRowStatus RowStatus
-- }
--
-- vdslPortVlanReg OBJECT-TYPE
-- SYNTAX INTEGER {
-- egress(1),
-- forbidden(2)
-- }
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "The port is egress or forbidden for this VLAN."
-- ::= { vdslPortVlanEntry 1 }
--
-- vdslPortVlanTag OBJECT-TYPE
-- SYNTAX INTEGER {
-- tag(1),
-- untag(2)
-- }
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "The port should transmit egress packets for this VLAN as tagged or untagged."
-- ::= { vdslPortVlanEntry 2 }
--
-- vdslPortVlanRowStatus OBJECT-TYPE
-- SYNTAX RowStatus
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "This object is used to create a new row or delete an existing row in this table."
-- ::= { vdslPortVlanEntry 3 }
-- vdslVlanStaticTable
-- vdslVlanStaticTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF VdslVlanStaticEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "A table containing static configuration information for
-- each VLAN configured into the device by (local or
-- network) management. All entries are permanent and will
-- be restored after the device is reset.
-- This table is supported by R2.00 and later versions."
-- ::= { vdslVlan 3 }
--
-- vdslVlanStaticEntry OBJECT-TYPE
-- SYNTAX VdslVlanStaticEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry in vdslVlanStaticTable."
-- INDEX { dot1qVlanIndex }
-- ::= { vdslVlanStaticTable 1 }
--
-- VdslVlanStaticEntry ::=
-- SEQUENCE {
-- vdslVlanStaticEgressPorts PortList,
-- vdslVlanStaticUntaggedPorts PortList,
-- vdslVlanStaticRowStatus RowStatus
-- }
--
-- vdslVlanStaticEgressPorts OBJECT-TYPE
-- SYNTAX PortList
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "The set of ports which are permanently assigned to the
-- egress list for this VLAN by management."
-- ::= { vdslVlanStaticEntry 1 }
--
-- vdslVlanStaticUntaggedPorts OBJECT-TYPE
-- SYNTAX PortList
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "The set of ports which should transmit egress packets for this VLAN as untagged."
-- ::= { vdslVlanStaticEntry 2 }
--
-- vdslVlanStaticRowStatus OBJECT-TYPE
-- SYNTAX RowStatus
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "This object indicates the status of this entry."
-- ::= { vdslVlanStaticEntry 3 }
-- vdslPortPvlanTable
vdslPortPvlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF VdslPortPvlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Protocol VLAN configuration table."
::= { vdslVlan 4 }
vdslPortPvlanEntry OBJECT-TYPE
SYNTAX VdslPortPvlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in vdslPortPvlanTable."
INDEX { ifIndex, vdslPortPvlanEtype }
::= { vdslPortPvlanTable 1 }
VdslPortPvlanEntry ::=
SEQUENCE {
vdslPortPvlanEtype Unsigned32,
vdslPortPvlanVid VlanIndex,
vdslPortPvlanPriority INTEGER,
vdslPortPvlanRowStatus RowStatus
}
vdslPortPvlanEtype OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"0~0xffff."
::= { vdslPortPvlanEntry 1 }
vdslPortPvlanVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
""
::= { vdslPortPvlanEntry 2 }
vdslPortPvlanPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
""
::= { vdslPortPvlanEntry 3 }
vdslPortPvlanRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
""
::= { vdslPortPvlanEntry 4 }
-- VDSL RFI Custom Table
vdslRfiCustomTable OBJECT-TYPE
SYNTAX SEQUENCE OF VdslRfiCustomEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes VDSL customized RFI configuration.
This table is supported by R2.00 and later versions."
::= { vdslPort 3 }
vdslRfiCustomEntry OBJECT-TYPE
SYNTAX VdslRfiCustomEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in vdslRfiCustomTable."
INDEX { vdslRfiCustomIndex }
::= { vdslRfiCustomTable 1 }
VdslRfiCustomEntry ::=
SEQUENCE {
vdslRfiCustomIndex INTEGER,
vdslRfiCustomStartFreq INTEGER,
vdslRfiCustomEndFreq INTEGER,
vdslRfiCustomEnable INTEGER
}
vdslRfiCustomIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the table."
::= { vdslRfiCustomEntry 1 }
vdslRfiCustomStartFreq OBJECT-TYPE
SYNTAX INTEGER
UNITS "KHz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The start value of the customized frequency range."
::= { vdslRfiCustomEntry 2 }
vdslRfiCustomEndFreq OBJECT-TYPE
SYNTAX INTEGER
UNITS "KHz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The end value of the customized frequency range."
::= { vdslRfiCustomEntry 3 }
vdslRfiCustomEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable the customized frequency range setting."
::= { vdslRfiCustomEntry 4 }
-- vdslLineConfUpboParamTable
vdslLineConfUpboParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF VdslLineConfUpboParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes VDSL UPBO configuration."
::= { vdslPort 4 }
vdslLineConfUpboParamEntry OBJECT-TYPE
SYNTAX VdslLineConfUpboParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in vdslLineConfUpboParamTable."
INDEX { ifIndex,vdslLineConfUpboParamBand }
::= { vdslLineConfUpboParamTable 1 }
VdslLineConfUpboParamEntry ::=
SEQUENCE {
vdslLineConfUpboParamBand INTEGER,
vdslLineConfUpboParamA INTEGER,
vdslLineConfUpboParamB INTEGER
}
vdslLineConfUpboParamBand OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the table."
::= { vdslLineConfUpboParamEntry 1 }
vdslLineConfUpboParamA OBJECT-TYPE
SYNTAX INTEGER (4000..8095)
UNITS "0.01 dBm/Hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { vdslLineConfUpboParamEntry 2 }
vdslLineConfUpboParamB OBJECT-TYPE
SYNTAX INTEGER (0..4095)
UNITS "0.01 dBm/Hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { vdslLineConfUpboParamEntry 3 }
-- vdslLineConfDpboTable
vdslLineConfDpboTable OBJECT-TYPE
SYNTAX SEQUENCE OF VdslLineConfDpboEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes VDSL DPBO configuration."
::= { vdslPort 5 }
vdslLineConfDpboEntry OBJECT-TYPE
SYNTAX VdslLineConfDpboEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in vdslLineConfDpboTable."
INDEX { ifIndex, vdslLineConfDpboIndex }
::= { vdslLineConfDpboTable 1 }
VdslLineConfDpboEntry ::=
SEQUENCE {
vdslLineConfDpboIndex INTEGER,
vdslLineConfDpboTone INTEGER,
vdslLineConfDpboPsd INTEGER
}
vdslLineConfDpboIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the table."
::= { vdslLineConfDpboEntry 1 }
vdslLineConfDpboTone OBJECT-TYPE
SYNTAX INTEGER (1..512)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { vdslLineConfDpboEntry 2 }
vdslLineConfDpboPsd OBJECT-TYPE
SYNTAX INTEGER (0..255)
UNITS "-0.5dBm/Hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { vdslLineConfDpboEntry 3 }
--------------------
-- pvc
--------------------
maxNumOfPvcs OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of PVCs which could be created on a port."
::= { pvc 1 }
-- PVC Table
pvcTable OBJECT-TYPE
SYNTAX SEQUENCE OF PvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes PVC configuration."
::= { pvc 2 }
pvcEntry OBJECT-TYPE
SYNTAX PvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in pvcTable."
INDEX { ifIndex, pvcVpi, pvcVci, pvcPvid }
::= { pvcTable 1 }
PvcEntry ::=
SEQUENCE {
-- Common --
pvcVpi INTEGER,
pvcVci INTEGER,
pvcPvid VlanIndex,
pvcPriority INTEGER,
pvcProfile DisplayString,
pvcAuto INTEGER,
-- Only for pvc --
pvcEncap INTEGER,
-- Only for paepvc --
pvcAcName DisplayString,
pvcServiceName DisplayString,
pvcHelloTime INTEGER,
-- Other --
pvcRowStatus RowStatus
}
-- Common --
pvcVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI of the pvc."
::= { pvcEntry 1 }
pvcVci OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI of the pvc."
::= { pvcEntry 2 }
pvcPvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Default VID of the pvc."
::= { pvcEntry 3 }
pvcPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"802.1p default priority of the pvc."
::= { pvcEntry 5 }
pvcProfile OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the row in the ipqosProfileTable.
"
::= { pvcEntry 6 }
pvcAuto OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/disable auto detection for PPPoE/PPPoA encapsulation."
::= { pvcEntry 14 }
-- Only for PVC --
pvcEncap OBJECT-TYPE
SYNTAX INTEGER {
llc(1),
vc(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Encapsulation of the pvc."
::= { pvcEntry 7 }
-- Other --
pvcRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in this table."
::= { pvcEntry 8 }
-- Only for PAEPVC --
pvcAcName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Access concentrator name for paepvc."
::= { pvcEntry 11 }
pvcServiceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Service name for paepvc."
::= { pvcEntry 12 }
pvcHelloTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The system will close the PVC if there are not any LCP echo messages passed through during the LCP hello time."
::= { pvcEntry 13 }
-- PVC state --
pvcStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF PvcStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table show current PVC status."
::= { pvc 3 }
pvcStateEntry OBJECT-TYPE
SYNTAX PvcStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in pvcStateTable."
INDEX { ifIndex, pvcStateVpi, pvcStateVci, pvcStatePvid }
::= { pvcStateTable 1 }
PvcStateEntry ::=
SEQUENCE {
pvcStateVpi INTEGER,
pvcStateVci INTEGER,
pvcStatePvid VlanIndex,
pvcStatePriority INTEGER,
--pvcStateCvid VlanIndex,
--pvcStateCPriority INTEGER,
--pvcStateMode DisplayString,
pvcStateChannelType DisplayString,
pvcStateEncap DisplayString
}
pvcStateVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI of the pvc."
::= { pvcStateEntry 1 }
pvcStateVci OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI of the pvc."
::= { pvcStateEntry 2 }
pvcStatePvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Default VID of the pvc."
::= { pvcStateEntry 3 }
pvcStatePriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"802.1p default priority of the pvc."
::= { pvcStateEntry 4 }
--pvcStateCvid OBJECT-TYPE
--SYNTAX VlanIndex
--MAX-ACCESS read-only
--STATUS current
--DESCRIPTION
--"Default C-VID for paepvc."
--::= { pvcStateEntry 5 }
--pvcStateCPriority OBJECT-TYPE
--SYNTAX INTEGER (0..7)
--MAX-ACCESS read-only
--STATUS current
--DESCRIPTION
--"802.1p default C-priority for paepvc."
--::= { pvcStateEntry 6 }
--pvcStateMode OBJECT-TYPE
--SYNTAX DisplayString (SIZE (1..31))
--MAX-ACCESS read-only
--STATUS current
--DESCRIPTION
--"The value of this object identifies the link mode at runntime."
--::= { pvcStateEntry 7 }
pvcStateChannelType OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the channel type at runtime."
::= { pvcStateEntry 8 }
pvcStateEncap OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the channel encapsulation at runtime."
::= { pvcStateEntry 9 }
-- Upstream Rate Limit Table
-- pvcUsRateLimitTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF PvcUsRateLimitEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table defines the upstream rate limit for each PVC."
-- ::= { pvc 4 }
--
-- pvcUsRateLimitEntry OBJECT-TYPE
-- SYNTAX PvcUsRateLimitEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry in pvcUsRateLimitTable."
-- INDEX { ifIndex, pvcVpi, pvcVci }
-- ::= { pvcUsRateLimitTable 1 }
--
-- PvcUsRateLimitEntry ::=
-- SEQUENCE {
-- pvcUsRateLimitEnable INTEGER,
-- pvcUsRateLimit INTEGER
-- }
--
-- pvcUsRateLimitEnable OBJECT-TYPE
-- SYNTAX INTEGER {
-- enable(1),
-- disable(2)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Enable/disable upstream rate limit for a PVC."
-- ::= { pvcUsRateLimitEntry 1 }
--
-- pvcUsRateLimit OBJECT-TYPE
-- SYNTAX INTEGER
-- UNITS "Kbps"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Upstream rate limit in Kbps for a PVC."
-- ::= { pvcUsRateLimitEntry 2 }
--
--------------------
-- priority pvc
--------------------
-- maxNumOfPriorityPvcs OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The maximum number of priority PVCs which could be created on a port."
-- ::= { ppvc 1 }
-- Priority PVC Table
-- ppvcTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF PpvcEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table includes priority PVC configuration."
-- ::= { ppvc 2 }
--
-- ppvcEntry OBJECT-TYPE
-- SYNTAX PpvcEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry in ppvcTable."
-- INDEX { ifIndex, ppvcVpi, ppvcVci, ppvcPvid }
-- ::= { ppvcTable 1 }
--
-- PpvcEntry ::=
-- SEQUENCE {
-- ppvcVpi INTEGER,
-- ppvcVci INTEGER,
-- ppvcPvid VlanIndex,
-- ppvcEncap INTEGER,
-- ppvcPriority INTEGER,
-- ppvcRowStatus RowStatus
-- }
--
-- ppvcVpi OBJECT-TYPE
-- SYNTAX INTEGER (0..255)
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "VPI of the ppvc."
-- ::= { ppvcEntry 1 }
--
-- ppvcVci OBJECT-TYPE
-- SYNTAX INTEGER (1..65535)
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "VCI of the ppvc."
-- ::= { ppvcEntry 2 }
--
-- ppvcPvid OBJECT-TYPE
-- SYNTAX VlanIndex
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Default VID of the ppvc."
-- ::= { ppvcEntry 3 }
--
-- ppvcEncap OBJECT-TYPE
-- SYNTAX INTEGER {
-- llc(1),
-- vc(2)
-- }
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "Encapsulation of the ppvc."
-- ::= { ppvcEntry 4 }
--
-- ppvcPriority OBJECT-TYPE
-- SYNTAX INTEGER (0..7)
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "802.1p default priority of the ppvc."
-- ::= { ppvcEntry 5 }
--
-- ppvcRowStatus OBJECT-TYPE
-- SYNTAX RowStatus
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "This object is used to create a new row or delete an existing row in this table."
-- ::= { ppvcEntry 6 }
-- Priority PVC Member Table
-- ppvcMemberTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF PpvcMemberEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table includes priority PVC member configuration."
-- ::= { ppvc 4 }
--
-- ppvcMemberEntry OBJECT-TYPE
-- SYNTAX PpvcMemberEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry in ppvcMemberTable."
-- INDEX { ifIndex, ppvcVpi, ppvcVci, ppvcMemberVpi, ppvcMemberVci, ppvcMemberPriority }
-- ::= { ppvcMemberTable 1 }
--
-- PpvcMemberEntry ::=
-- SEQUENCE {
-- ppvcMemberVpi INTEGER,
-- ppvcMemberVci INTEGER,
-- ppvcMemberPriority INTEGER,
-- ppvcMemberProfileDS DisplayString,
-- ppvcMemberRowStatus RowStatus,
-- ppvcMemberProfileUS DisplayString
-- }
--
-- ppvcMemberVpi OBJECT-TYPE
-- SYNTAX INTEGER (0..255)
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "VPI of the member ppvc."
-- ::= { ppvcMemberEntry 1 }
--
-- ppvcMemberVci OBJECT-TYPE
-- SYNTAX INTEGER (1..65535)
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "VCI of the member ppvc."
-- ::= { ppvcMemberEntry 2 }
--
-- ppvcMemberPriority OBJECT-TYPE
-- SYNTAX INTEGER (0..7)
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "802.1p default priority of the member ppvc."
-- ::= { ppvcMemberEntry 3 }
--
-- ppvcMemberProfileDS OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (1..31))
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "The profile of the member ppvc in DS side."
-- ::= { ppvcMemberEntry 4 }
--
-- ppvcMemberRowStatus OBJECT-TYPE
-- SYNTAX RowStatus
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "This object is used to create a new row or delete an existing row in this table."
-- ::= { ppvcMemberEntry 5 }
--
-- ppvcMemberProfileUS OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (1..31))
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "The profile of the member ppvc in US side."
-- ::= { ppvcMemberEntry 6 }
-------------------------------
-- 2684 routed mode pvc (rpvc)
-------------------------------
-- Routed Gateway Table
rpvcGatewayTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpvcGatewayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes Routed Gateway configuration."
::= { rpvc 1 }
rpvcGatewayEntry OBJECT-TYPE
SYNTAX RpvcGatewayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in Routed Gateway table."
INDEX { rpvcGatewayIp }
::= { rpvcGatewayTable 1 }
RpvcGatewayEntry ::=
SEQUENCE {
rpvcGatewayIp IpAddress,
rpvcGatewayVlanId VlanIndex,
rpvcGatewayRowStatus RowStatus,
rpvcGatewayPriority INTEGER
}
rpvcGatewayIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP of RPVC gateway."
::= { rpvcGatewayEntry 1 }
rpvcGatewayVlanId OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Vlan id send to this RPVC gateway."
::= { rpvcGatewayEntry 2 }
rpvcGatewayRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in this table."
::= { rpvcGatewayEntry 3 }
rpvcGatewayPriority OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"802.1p p bit send to this RPVC gateway."
::= { rpvcGatewayEntry 4 }
-- Routed PVC Table
rpvcTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes RPVC configuration."
::= { rpvc 2 }
rpvcEntry OBJECT-TYPE
SYNTAX RpvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in rpvcTable."
INDEX { ifIndex, rpvcVpi, rpvcVci, rpvcIp, rpvcNetmask }
::= { rpvcTable 1 }
RpvcEntry ::=
SEQUENCE {
rpvcVpi INTEGER,
rpvcVci INTEGER,
rpvcEncap INTEGER,
rpvcProfile DisplayString,
rpvcIp IpAddress,
rpvcNetmask IpAddress,
rpvcGatewayIpAddress IpAddress,
rpvcRowStatus RowStatus
}
rpvcVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI of the rpvc."
::= { rpvcEntry 1 }
rpvcVci OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI of the rpvc."
::= { rpvcEntry 2 }
rpvcEncap OBJECT-TYPE
SYNTAX INTEGER {
llc(1),
vc(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Encapsulation of the rpvc."
::= { rpvcEntry 3 }
rpvcProfile OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ipqos profile of the rpvc."
::= { rpvcEntry 4 }
rpvcIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP of the rpvc."
::= { rpvcEntry 5 }
rpvcNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP mask of the rpvc IP."
::= { rpvcEntry 6 }
rpvcGatewayIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The gateway IP of rpvc."
::= { rpvcEntry 7 }
rpvcRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in this table."
::= { rpvcEntry 8 }
-- Routed PVC Routed Domain Table
rpvcRouteDomainTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpvcRouteDomainEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes RPVC route domain configuration."
::= { rpvc 3 }
rpvcRouteDomainEntry OBJECT-TYPE
SYNTAX RpvcRouteDomainEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in rpvcRouteDomainTable."
INDEX { ifIndex, rpvcRouteDomainVpi, rpvcRouteDomainVci, rpvcRouteDomainIp, rpvcRouteDomainNetmask }
::= { rpvcRouteDomainTable 1 }
RpvcRouteDomainEntry ::=
SEQUENCE {
rpvcRouteDomainVpi INTEGER,
rpvcRouteDomainVci INTEGER,
rpvcRouteDomainIp IpAddress,
rpvcRouteDomainNetmask IpAddress,
rpvcRouteDomainRowStatus RowStatus
}
rpvcRouteDomainVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI of the rpvc."
::= { rpvcRouteDomainEntry 1 }
rpvcRouteDomainVci OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI of the rpvc."
::= { rpvcRouteDomainEntry 2 }
rpvcRouteDomainIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The route domain IP."
::= { rpvcRouteDomainEntry 3 }
rpvcRouteDomainNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP mask of the route domain IP."
::= { rpvcRouteDomainEntry 4 }
rpvcRouteDomainRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in this table."
::= { rpvcRouteDomainEntry 5 }
rpvcArpAgingTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set RPVC ARP proxy aging time 10..10000 seconds,
0 to disable againg."
::= { rpvc 4 }
rpvcArpFlush OBJECT-TYPE
SYNTAX INTEGER {
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Flush the RPVC ARP proxy table."
::= { rpvc 5 }
--------------------
-- dsBcastDisableTable
--------------------
dsBcastDisableTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsBcastDisableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes Down Stream Bcast configuration."
::= { port 9 }
dsBcastDisableEntry OBJECT-TYPE
SYNTAX DsBcastDisableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in Down Stream Bcast table."
INDEX { ifIndex, dsBcastDisableVlanId }
::= { dsBcastDisableTable 1 }
DsBcastDisableEntry ::=
SEQUENCE {
dsBcastDisableVlanId INTEGER,
dsBcastDisableRowStatus RowStatus
}
dsBcastDisableVlanId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"downstream broadcast disabled vid."
::= { dsBcastDisableEntry 1 }
dsBcastDisableRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in this table."
::= { dsBcastDisableEntry 2 }
--------------------
-- paepvc
--------------------
-- PPPoAoE PVC Table
paepvcTable OBJECT-TYPE
SYNTAX SEQUENCE OF PaepvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes PPPoAoE PVC configuration."
::= { paepvc 1 }
paepvcEntry OBJECT-TYPE
SYNTAX PaepvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of paepvcTable."
INDEX { ifIndex, paepvcVpi, paepvcVci, paepvcPvid }
::= { paepvcTable 1 }
PaepvcEntry ::=
SEQUENCE {
paepvcVpi INTEGER,
paepvcVci INTEGER,
paepvcPvid VlanIndex,
paepvcEncap INTEGER,
paepvcPriority INTEGER,
paepvcProfile DisplayString,
paepvcAcName DisplayString,
paepvcServiceName DisplayString,
paepvcHelloTime INTEGER,
paepvcRowStatus RowStatus,
paepvcCvid VlanIndex,
paepvcCPriority INTEGER
}
paepvcVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI of the pvc."
::= { paepvcEntry 1 }
paepvcVci OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI of the pvc."
::= { paepvcEntry 2 }
paepvcPvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Default VID of the pvc."
::= { paepvcEntry 3 }
paepvcEncap OBJECT-TYPE
SYNTAX INTEGER {
llc(1),
vc(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Encapsulation of the paepvc."
::= { paepvcEntry 4 }
paepvcPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"802.1p default priority of the pvc."
::= { paepvcEntry 5 }
paepvcProfile OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the row in the ipqosProfileTable."
::= { paepvcEntry 6 }
paepvcAcName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Access concentrator name."
::= { paepvcEntry 7 }
paepvcServiceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Service name."
::= { paepvcEntry 8 }
paepvcHelloTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The system will close the PVC if there are not any LCP echo messages passed through
during the LCP hello time."
::= { paepvcEntry 9 }
paepvcRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in this table."
::= { paepvcEntry 10 }
paepvcCvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Default C-VID of the pvc."
::= { paepvcEntry 12 }
paepvcCPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"802.1p default C-priority of the pvc."
::= { paepvcEntry 13 }
--------------------
-- tlspvc
--------------------
-- TLS PVC Table
tlspvcTable OBJECT-TYPE
SYNTAX SEQUENCE OF TlspvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes Transparent LAN Service (TLS) PVC configuration."
::= { tlspvc 1 }
tlspvcEntry OBJECT-TYPE
SYNTAX TlspvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of tlspvcTable."
INDEX { ifIndex, tlspvcVpi, tlspvcVci, tlspvcSvid }
::= { tlspvcTable 1 }
TlspvcEntry ::=
SEQUENCE {
tlspvcVpi INTEGER,
tlspvcVci INTEGER,
tlspvcSvid VlanIndex,
tlspvcEncap INTEGER,
tlspvcSpriority INTEGER,
tlspvcProfile DisplayString,
tlspvcRowStatus RowStatus
}
tlspvcVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI of the pvc."
::= { tlspvcEntry 1 }
tlspvcVci OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI of the pvc."
::= { tlspvcEntry 2 }
tlspvcSvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"s-tag VLAN ID of the pvc."
::= { tlspvcEntry 3 }
tlspvcEncap OBJECT-TYPE
SYNTAX INTEGER {
llc(1),
vc(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Encapsulation of the tlspvc."
::= { tlspvcEntry 4 }
tlspvcSpriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"s-tag priority of the pvc."
::= { tlspvcEntry 5 }
tlspvcProfile OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the row in the ipqosProfileTable."
::= { tlspvcEntry 6 }
tlspvcRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in this table."
::= { tlspvcEntry 7 }
--------------------
-- ipbpvc
--------------------
-- Domain Table
-- ipbpvcDomainTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF IpbpvcDomainEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table includes ipbpvc domain configuration.
-- This table is supported by R3.00 and later versions."
-- ::= { ipbpvc 1 }
--
-- ipbpvcDomainEntry OBJECT-TYPE
-- SYNTAX IpbpvcDomainEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry of ipbpvcDomainTable."
-- INDEX { ipbpvcDomainName }
-- ::= { ipbpvcDomainTable 1 }
--
-- IpbpvcDomainEntry ::=
-- SEQUENCE {
-- ipbpvcDomainName OCTET STRING,
-- ipbpvcDomainRowStatus RowStatus
-- }
--
-- ipbpvcDomainName OBJECT-TYPE
-- SYNTAX OCTET STRING
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Name of the domain."
-- ::= { ipbpvcDomainEntry 1 }
--
-- ipbpvcDomainRowStatus OBJECT-TYPE
-- SYNTAX RowStatus
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "Row status of the table."
-- ::= { ipbpvcDomainEntry 2 }
-- Domain VLAN Table
-- ipbpvcDomainVlanTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF IpbpvcDomainVlanEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table includes ipbpvc domain VLAN configuration.
-- This table is supported by R3.00 and later versions."
-- ::= { ipbpvc 2 }
--
-- ipbpvcDomainVlanEntry OBJECT-TYPE
-- SYNTAX IpbpvcDomainVlanEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry of ipbpvcDomainVlanTable."
-- INDEX { ipbpvcDomainName, ipbpvcDomainVlanId }
-- ::= { ipbpvcDomainVlanTable 1 }
--
-- IpbpvcDomainVlanEntry ::=
-- SEQUENCE {
-- ipbpvcDomainVlanId VlanIndex,
-- ipbpvcDomainDhcpVlanEnable INTEGER,
-- ipbpvcDomainVlanRowStatus RowStatus
-- }
--
-- ipbpvcDomainVlanId OBJECT-TYPE
-- SYNTAX VlanIndex
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Set VLAN to join or leave the specified domain."
-- ::= { ipbpvcDomainVlanEntry 1 }
--
-- ipbpvcDomainDhcpVlanEnable OBJECT-TYPE
-- SYNTAX INTEGER {
-- enable(1),
-- disable(2)
-- }
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "Enable/disable DHCP VLAN in a domain."
-- ::= { ipbpvcDomainVlanEntry 2 }
--
-- ipbpvcDomainVlanRowStatus OBJECT-TYPE
-- SYNTAX RowStatus
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "Row status of the table used to create/delete an entry."
-- ::= { ipbpvcDomainVlanEntry 3 }
-- Edge Router Table
-- ipbpvcEdgeRouterTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF IpbpvcEdgeRouterEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table includes ipbpvc edge router configuration.
-- This table is supported by R3.00 and later versions."
-- ::= { ipbpvc 3 }
--
-- ipbpvcEdgeRouterEntry OBJECT-TYPE
-- SYNTAX IpbpvcEdgeRouterEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry of ipbpvcEdgeRouterTable."
-- INDEX { ipbpvcDomainName, ipbpvcEdgeRouterIp, ipbpvcEdgeRouterMask, ipbpvcEdgeRouterVid }
-- ::= { ipbpvcEdgeRouterTable 1 }
--
-- IpbpvcEdgeRouterEntry ::=
-- SEQUENCE {
-- ipbpvcEdgeRouterIp IpAddress,
-- ipbpvcEdgeRouterMask INTEGER,
-- ipbpvcEdgeRouterVid VlanIndex,
-- ipbpvcEdgeRouterRowStatus RowStatus
-- }
--
-- ipbpvcEdgeRouterIp OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "IP address of the edge router."
-- ::= { ipbpvcEdgeRouterEntry 1 }
--
-- ipbpvcEdgeRouterVid OBJECT-TYPE
-- SYNTAX VlanIndex
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "VLAN ID of the edge router."
-- ::= { ipbpvcEdgeRouterEntry 2 }
--
-- ipbpvcEdgeRouterMask OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Netmask of the edge router."
-- ::= { ipbpvcEdgeRouterEntry 3 }
--
-- ipbpvcEdgeRouterRowStatus OBJECT-TYPE
-- SYNTAX RowStatus
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "Row status of the table used to create/delete an entry."
-- ::= { ipbpvcEdgeRouterEntry 4 }
-- Interface Table
-- ipbpvcInterfaceTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF IpbpvcInterfaceEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table includes ipbpvc interface configuration.
-- This table is supported by R3.00 and later versions."
-- ::= { ipbpvc 4 }
--
-- ipbpvcInterfaceEntry OBJECT-TYPE
-- SYNTAX IpbpvcInterfaceEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry of ipbpvcInterfaceTable."
-- INDEX { ipbpvcDomainName, ipbpvcInterfaceIp, ipbpvcInterfaceMask, ipbpvcInterfaceVid }
-- ::= { ipbpvcInterfaceTable 1 }
--
-- IpbpvcInterfaceEntry ::=
-- SEQUENCE {
-- ipbpvcInterfaceIp IpAddress,
-- ipbpvcInterfaceMask INTEGER,
-- ipbpvcInterfaceVid VlanIndex,
-- ipbpvcInterfaceIfIndex INTEGER,
-- ipbpvcInterfaceVpi INTEGER,
-- ipbpvcInterfaceVci INTEGER,
-- ipbpvcInterfaceRowStatus RowStatus
-- }
--
-- ipbpvcInterfaceIp OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "IP address of the interface."
-- ::= { ipbpvcInterfaceEntry 1 }
--
-- ipbpvcInterfaceMask OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Netmask of the interface."
-- ::= { ipbpvcInterfaceEntry 2 }
--
-- ipbpvcInterfaceVid OBJECT-TYPE
-- SYNTAX VlanIndex
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "VLAN ID of the interface."
-- ::= { ipbpvcInterfaceEntry 3 }
--
-- ipbpvcInterfaceIfIndex OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "IfIndex of the interface."
-- ::= { ipbpvcInterfaceEntry 4 }
--
-- ipbpvcInterfaceVpi OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "VPI of the interface."
-- ::= { ipbpvcInterfaceEntry 5 }
--
-- ipbpvcInterfaceVci OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "VCI of the interface."
-- ::= { ipbpvcInterfaceEntry 6 }
--
-- ipbpvcInterfaceRowStatus OBJECT-TYPE
-- SYNTAX RowStatus
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "Row status of the table used to create/delete an entry."
-- ::= { ipbpvcInterfaceEntry 7 }
-- Route Table
-- ipbpvcRouteTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF IpbpvcRouteEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table includes ipbpvc route configuration.
-- This table is supported by R3.00 and later versions."
-- ::= { ipbpvc 5 }
--
-- ipbpvcRouteEntry OBJECT-TYPE
-- SYNTAX IpbpvcRouteEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry of ipbpvcRouteTable."
-- INDEX { ipbpvcDomainName, ipbpvcRouteIp, ipbpvcRouteMask, ipbpvcRouteNextHop }
-- ::= { ipbpvcRouteTable 1 }
--
-- IpbpvcRouteEntry ::=
-- SEQUENCE {
-- ipbpvcRouteIp IpAddress,
-- ipbpvcRouteMask INTEGER,
-- ipbpvcRouteNextHop IpAddress,
-- ipbpvcRouteMetric INTEGER,
-- ipbpvcRoutePriority INTEGER,
-- ipbpvcRouteRowStatus RowStatus
-- }
--
-- ipbpvcRouteIp OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "IP address of the route."
-- ::= { ipbpvcRouteEntry 1 }
--
-- ipbpvcRouteMask OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Netmask of the route."
-- ::= { ipbpvcRouteEntry 2 }
--
-- ipbpvcRouteNextHop OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Next hop IP address of the route."
-- ::= { ipbpvcRouteEntry 3 }
--
-- ipbpvcRouteMetric OBJECT-TYPE
-- SYNTAX INTEGER (1..15)
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "Metric of the route."
-- ::= { ipbpvcRouteEntry 4 }
--
-- ipbpvcRoutePriority OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "Priority of the route. Note that the default value of this object is 8, which means
-- we keep the original priority of the packet(frame)."
-- ::= { ipbpvcRouteEntry 5 }
--
-- ipbpvcRouteRowStatus OBJECT-TYPE
-- SYNTAX RowStatus
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "Row status of the table used to create/delete an entry."
-- ::= { ipbpvcRouteEntry 6 }
-- PVC Table
-- ipbpvcTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF IpbpvcEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table includes ipbpvc configuration.
-- This table is supported by R3.00 and later versions."
-- ::= { ipbpvc 6 }
--
-- ipbpvcEntry OBJECT-TYPE
-- SYNTAX IpbpvcEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry of ipbpvcTable."
-- INDEX { ifIndex, ipbpvcVpi, ipbpvcVci, ipbpvcPvid }
-- ::= { ipbpvcTable 1 }
--
-- IpbpvcEntry ::=
-- SEQUENCE {
-- ipbpvcVpi INTEGER,
-- ipbpvcVci INTEGER,
-- ipbpvcPvid INTEGER,
-- ipbpvcEncap INTEGER,
-- ipbpvcPriority INTEGER,
-- ipbpvcProfile OCTET STRING,
-- ipbpvcRowStatus RowStatus,
-- ipbpvcProfileUS OCTET STRING
-- }
--
-- ipbpvcVpi OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "VPI of the PVC."
-- ::= { ipbpvcEntry 1 }
--
-- ipbpvcVci OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "VCI of the PVC."
-- ::= { ipbpvcEntry 2 }
--
-- ipbpvcPvid OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "PVID of the PVC."
-- ::= { ipbpvcEntry 3 }
--
-- ipbpvcEncap OBJECT-TYPE
-- SYNTAX INTEGER {
-- ipoe(1),
-- reserved(2),
-- ipoa(3)
-- }
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "Type of the PVC."
-- ::= { ipbpvcEntry 4 }
--
-- ipbpvcPriority OBJECT-TYPE
-- SYNTAX INTEGER (0..7)
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "Priority of the PVC."
-- ::= { ipbpvcEntry 5 }
--
-- ipbpvcProfile OBJECT-TYPE
-- SYNTAX OCTET STRING
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "Profile of the PVC."
-- ::= { ipbpvcEntry 6 }
--
-- ipbpvcRowStatus OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "Row status of the table used to create/delete an entry."
-- ::= { ipbpvcEntry 7 }
--
-- ipbpvcProfileUS OBJECT-TYPE
-- SYNTAX OCTET STRING
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "US Profile of the PVC."
-- ::= { ipbpvcEntry 8 }
-- ARP Proxy
-- arpproxy OBJECT IDENTIFIER ::= { ipbpvc 8 }
--
-- arpproxyAge OBJECT-TYPE
-- SYNTAX INTEGER (10..10000)
-- UNITS "second"
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Aging time of the ARP proxy.
-- This object is supported by R3.00 and later versions."
-- ::= { arpproxy 1 }
--
-- arpproxyFlush OBJECT IDENTIFIER ::= { arpproxy 2 }
--
-- arpproxyFlushTarget OBJECT-TYPE
-- SYNTAX INTEGER {
-- all(1),
-- edgerouter(2),
-- interface(3)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The target whose ARP table to be flushed.
-- This object is supported by R3.00 and later versions."
-- ::= { arpproxyFlush 1 }
--
-- arpproxyFlushOps OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Set the object to 1 to start flushing.
-- This object is supported by R3.00 and later versions."
-- ::= { arpproxyFlush 2 }
--
-- arpproxyFlushEdgeRouterIp OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Flush ARP table for the specified edge router.
-- This object is supported by R3.00 and later versions."
-- ::= { arpproxyFlush 3 }
--
-- arpproxyFlushEdgeRouterVid OBJECT-TYPE
-- SYNTAX VlanIndex
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Flush ARP table for the specified edge router.
-- This object is supported by R3.00 and later versions."
-- ::= { arpproxyFlush 4 }
--
-- arpproxyFlushInterfaceIp OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Flush ARP table for the specified interface.
-- This object is supported by R3.00 and later versions."
-- ::= { arpproxyFlush 5 }
--
-- arpproxyFlushInterfaceMask OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Flush ARP table for the specified interface.
-- This object is supported by R3.00 and later versions."
-- ::= { arpproxyFlush 6 }
--
-- arpproxyFlushInterfaceVid OBJECT-TYPE
-- SYNTAX VlanIndex
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Flush ARP table for the specified interface.
-- This object is supported by R3.00 and later versions."
-- ::= { arpproxyFlush 7 }
--
--------------------
-- dtpvc
--------------------
-- DT PVC Table
dtpvcTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtpvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes Double Tagging (DT) PVC configuration."
::= { dtpvc 1 }
dtpvcEntry OBJECT-TYPE
SYNTAX DtpvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dtpvcTable."
INDEX { ifIndex, dtpvcVpi, dtpvcVci, dtpvcSvid }
::= { dtpvcTable 1 }
DtpvcEntry ::=
SEQUENCE {
-- Common --
dtpvcVpi INTEGER,
dtpvcVci INTEGER,
dtpvcSvid VlanIndex,
dtpvcSpriority INTEGER,
dtpvcCvid VlanIndex,
dtpvcCpriority INTEGER,
dtpvcEncap INTEGER,
dtpvcProfile DisplayString,
dtpvcRowStatus RowStatus,
dtpvcAuto INTEGER,
-- Only for dtpvc --
dtpvcSuperChannel INTEGER,
-- Only for paepvc --
dtpvcAcName DisplayString,
dtpvcServiceName DisplayString,
dtpvcHelloTime INTEGER
}
-- Common --
dtpvcVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI of the pvc."
::= { dtpvcEntry 1 }
dtpvcVci OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI of the pvc."
::= { dtpvcEntry 2 }
dtpvcSvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"s-tag VLAN ID of the pvc."
::= { dtpvcEntry 3 }
dtpvcSpriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"s-tag priority of the pvc."
::= { dtpvcEntry 4 }
dtpvcCvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"c-tag VLAN ID of the pvc."
::= { dtpvcEntry 5 }
dtpvcCpriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"c-tag priority of the pvc."
::= { dtpvcEntry 6 }
dtpvcEncap OBJECT-TYPE
SYNTAX INTEGER {
llc(1),
vc(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Encapsulation of the dtpvc."
::= { dtpvcEntry 7 }
dtpvcProfile OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the row in the ipqosProfileTable."
::= { dtpvcEntry 8 }
dtpvcRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in this table."
::= { dtpvcEntry 9 }
dtpvcAuto OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/disable auto detection for PPPoE/PPPoA encapsulation."
::= { dtpvcEntry 14 }
-- Only for DTPVC --
dtpvcSuperChannel OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specified the configured DTPVC is a super channel."
::= { dtpvcEntry 10 }
-- Only for PAEPVC --
dtpvcAcName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Access concentrator name for paepvc."
::= { dtpvcEntry 11 }
dtpvcServiceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Service name for paepvc."
::= { dtpvcEntry 12 }
dtpvcHelloTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The system will close the PVC if there are not any LCP echo messages passed through during the LCP hello time."
::= { dtpvcEntry 13 }
-- DTPVC state --
dtpvcStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtpvcStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table show current DTPVC status."
::= { dtpvc 2 }
dtpvcStateEntry OBJECT-TYPE
SYNTAX DtpvcStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in dtpvcStateTable."
INDEX { ifIndex, dtpvcStateVpi, dtpvcStateVci, dtpvcStateSvid }
::= { dtpvcStateTable 1 }
DtpvcStateEntry ::=
SEQUENCE {
dtpvcStateVpi INTEGER,
dtpvcStateVci INTEGER,
dtpvcStateSvid VlanIndex,
dtpvcStateSPriority INTEGER,
dtpvcStateCvid VlanIndex,
dtpvcStateCPriority INTEGER,
--dtpvcStateMode DisplayString,
dtpvcStateChannelType DisplayString,
dtpvcStateEncap DisplayString
}
dtpvcStateVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI of the dtpvc."
::= { dtpvcStateEntry 1 }
dtpvcStateVci OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI of the dtpvc."
::= { dtpvcStateEntry 2 }
dtpvcStateSvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Default S-VID of the dtpvc."
::= { dtpvcStateEntry 3 }
dtpvcStateSPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"S-priority of the dtpvc."
::= { dtpvcStateEntry 4 }
dtpvcStateCvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Default C-VID of the dtpvc."
::= { dtpvcStateEntry 5 }
dtpvcStateCPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"C-priority of the dtpvc."
::= { dtpvcStateEntry 6 }
--dtpvcStateMode OBJECT-TYPE
--SYNTAX DisplayString (SIZE (1..31))
--MAX-ACCESS read-only
--STATUS current
--DESCRIPTION
--"The value of this object identifies the link mode at runntime."
--::= { dtpvcStateEntry 7 }
dtpvcStateChannelType OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the channel type at runtime."
::= { dtpvcStateEntry 8 }
dtpvcStateEncap OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the channel encapsulation at runtime."
::= { dtpvcStateEntry 9 }
--------------------
-- snrMgn
--------------------
-- snrMgnTable
snrMgnTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnrMarginEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing the per port SNR Margin configuration."
::= { snrMgn 1 }
snrMgnEntry OBJECT-TYPE
SYNTAX SnrMarginEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of snrMgnTable."
INDEX { ifIndex }
::= { snrMgnTable 1 }
SnrMarginEntry ::=
SEQUENCE {
snrMgnMode INTEGER,
snrMgnUcTarget INTEGER,
snrMgnUcMax INTEGER,
snrMgnUcMin INTEGER,
snrMgnUcDownshift INTEGER,
snrMgnUcUpshift INTEGER,
snrMgnUrTarget INTEGER,
snrMgnUrMax INTEGER,
snrMgnUrMin INTEGER,
snrMgnUrDownshift INTEGER,
snrMgnUrUpshift INTEGER
}
snrMgnMode OBJECT-TYPE
SYNTAX INTEGER {
profile(0),
line(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure DSL SNR margin configuration mode of the specified ports.
Profile: the SNR margin configuration comes from DSL profile.
Line: the SNR margin configuration comes from line configuration."
::= { snrMgnEntry 1 }
snrMgnUcTarget OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Target Signal/Noise Margin.
This is the Noise Margin the modem must achieve
with a BER of 10-7 or better to successfully complete
initialization."
::= { snrMgnEntry 2 }
snrMgnUcMax OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Maximum acceptable Signal/Noise Margin.
If the Noise Margin is above this the modem should
attempt to reduce its power output to optimize its
operation."
::= { snrMgnEntry 3 }
snrMgnUcMin OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Minimum acceptable Signal/Noise Margin.
If the noise margin falls below this level, the modem
should attempt to increase its power output. If that
is not possible the modem will attempt to
re-initialize or shut down."
::= { snrMgnEntry 4 }
snrMgnUcDownshift OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Signal/Noise Margin for rate downshift.
If the noise margin falls below this level, the modem
should attempt to decrease its transmit rate. In
the case that RADSL mode is not present,
the value will be `0'."
::= { snrMgnEntry 5 }
snrMgnUcUpshift OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Signal/Noise Margin for rate upshift.
If the noise margin rises above this level, the modem
should attempt to increase its transmit rate. In
the case that RADSL is not present, the value will
be `0'."
::= { snrMgnEntry 6 }
snrMgnUrTarget OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Target Signal/Noise Margin.
This is the Noise Margin the modem must achieve
with a BER of 10-7 or better to successfully complete
initialization."
::= { snrMgnEntry 7 }
snrMgnUrMax OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Maximum acceptable Signal/Noise Margin.
If the Noise Margin is above this the modem should
attempt to reduce its power output to optimize its
operation."
::= { snrMgnEntry 8 }
snrMgnUrMin OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Minimum acceptable Signal/Noise Margin.
If the noise margin falls below this level, the modem
should attempt to increase its power output. If that
is not possible the modem will attempt to
re-initialize or shut down."
::= { snrMgnEntry 9 }
snrMgnUrDownshift OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Signal/Noise Margin for rate downshift.
If the noise margin falls below this level, the modem
should attempt to decrease its transmit rate.
In the case that RADSL mode is not present,
the value will be `0'."
::= { snrMgnEntry 10 }
snrMgnUrUpshift OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Signal/Noise Margin for rate upshift.
If the noise margin rises above this level, the modem
should attempt to increase its transmit rate.
In the case that RADSL is not present,
the value will be `0'."
::= { snrMgnEntry 11 }
--------------------
-- dsl rate
--------------------
-- dslRateTable
dslRateTable OBJECT-TYPE
SYNTAX SEQUENCE OF DslRateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing the per port DSL Rate configuration."
::= { dslRate 1 }
dslRateEntry OBJECT-TYPE
SYNTAX DslRateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dslRateTable."
INDEX { ifIndex }
::= { dslRateTable 1 }
DslRateEntry ::=
SEQUENCE {
dslRateMode INTEGER,
dslRateLatencyMode INTEGER,
dslRateXtucMaxInterleaveDelay INTEGER,
dslRateXtucMaxTxRate Unsigned32,
dslRateXtucMinTxRate Unsigned32,
dslRateXturMaxInterleaveDelay INTEGER,
dslRateXturMaxTxRate Unsigned32,
dslRateXturMinTxRate Unsigned32
}
dslRateMode OBJECT-TYPE
SYNTAX INTEGER {
profile(0),
line(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure DSL Rate configuration mode of the specified ports.
Profile: the DSL Rate configuration comes from DSL profile.
Line: the DSL Rate configuration comes from line configuration."
::= { dslRateEntry 1 }
dslRateLatencyMode OBJECT-TYPE
SYNTAX INTEGER {
interleave(1),
fast(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The latency mode is fast or interleave"
::= { dslRateEntry 2 }
dslRateXtucMaxInterleaveDelay OBJECT-TYPE
SYNTAX INTEGER (0..255)
UNITS "milli-seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured maximum Interleave Delay for this channel.
Interleave delay applies only to the interleave channel
and defines the mapping (relative spacing) between
subsequent input bytes at the interleaver input and
their placement in the bit stream at the interleaver
output. Larger numbers provide greater separation
between consecutive input bytes in the output bit
stream allowing for improved impulse noise immunity
at the expense of payload latency."
::= { dslRateEntry 3 }
dslRateXtucMaxTxRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Maximum Transmit rate for `Fast' or `Interleave' channels,
in bps."
::= { dslRateEntry 4 }
dslRateXtucMinTxRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Minimum Transmit rate for `Fast' or `Interleave' channels,
in bps"
::= { dslRateEntry 5 }
dslRateXturMaxInterleaveDelay OBJECT-TYPE
SYNTAX INTEGER (0..255)
UNITS "milli-seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured maximum Interleave Delay for this channel.
Interleave delay applies only to the interleave channel
and defines the mapping (relative spacing) between
subsequent input bytes at the interleaver input and
their placement in the bit stream at the interleaver
output. Larger numbers provide greater separation
between consecutive input bytes in the output bit
stream allowing for improved impulse noise immunity
at the expense of payload latency"
::= { dslRateEntry 6 }
dslRateXturMaxTxRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Target Signal/Noise Margin.
This is the Noise Margin the modem must achieve
with a BER of 10-7 or better to successfully complete
initialization."
::= { dslRateEntry 7 }
dslRateXturMinTxRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Maximum Transmit rate for `Fast' or `Interleave' channels,
in bps."
::= { dslRateEntry 8 }
--------------------
-- gbond
--------------------
-- gbondTable
gbondGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF GbondGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing the G.Bond configuration information for
each bonding group of the device."
::= { gbond 1 }
gbondGroupEntry OBJECT-TYPE
SYNTAX GbondGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of gbondTable."
INDEX { gbondGroupName }
::= { gbondGroupTable 1 }
GbondGroupEntry ::=
SEQUENCE {
gbondGroupName OCTET STRING,
gbondGroupPorts OCTET STRING,
-- gbondGroupSid INTEGER,
gbondGroupUpRate Unsigned32,
gbondGroupDownRate Unsigned32,
gbondGroupRowStatus RowStatus
}
gbondGroupName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An administratively assigned string, which may be used to identify bonding group."
::= { gbondGroupEntry 1 }
gbondGroupPorts OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The set of ports which are currently assigned to the
bonding group of specified group name.
Byte 1: Reserved(chassis)
Byte 2~3: Reserved(slot)
Byte 4: Reserved
Byte 5~11:each octet specifies a set of eight ports, with the first
octet specifying ports 1 through 8, etc."
::= { gbondGroupEntry 2 }
-- gbondGroupSid OBJECT-TYPE
-- SYNTAX INTEGER {
-- sid8(1),
-- sid12(2)
-- }
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "This object indicates the sequence index mode of the bonding group."
-- ::= { gbondGroupEntry 3 }
gbondGroupUpRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The UP stream rate."
::= { gbondGroupEntry 4 }
gbondGroupDownRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DOWN stream rate."
::= { gbondGroupEntry 5 }
gbondGroupRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the status of this entry."
::= { gbondGroupEntry 6 }
----------------------------------------
-- profile
----------------------------------------
sraShiftMarginProfile OBJECT IDENTIFIER ::= { profile 1 }
ipqosProfile OBJECT IDENTIFIER ::= { profile 8 }
--------------------
-- sraShiftMarginProfile
--------------------
-- sraShiftMarginProfile
sraShiftMarginProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF SraShiftMarginProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes sra shift margin related configuration."
::= { sraShiftMarginProfile 1 }
sraShiftMarginProfileEntry OBJECT-TYPE
SYNTAX SraShiftMarginProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in ipqosProfileTable."
INDEX { sraShiftMarginProfileName }
::= { sraShiftMarginProfileTable 1 }
SraShiftMarginProfileEntry ::=
SEQUENCE {
sraShiftMarginProfileName DisplayString,
xtucConfDownshiftSnrMgn INTEGER,
xtucConfUpshiftSnrMgn INTEGER,
xtucConfDownshiftTime INTEGER,
xtucConfUpshiftTime INTEGER,
xturConfDownshiftSnrMgn INTEGER,
xturConfUpshiftSnrMgn INTEGER,
xturConfDownshiftTime INTEGER,
xturConfUpshiftTime INTEGER,
sraShiftMarginProfileStatus RowStatus
}
sraShiftMarginProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies a row in this table."
::= { sraShiftMarginProfileEntry 1 }
xtucConfDownshiftSnrMgn OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the downstream SRA Down Shift Margin in units of 0.25 dB, for a range of 0 to 31.75 dB. in unit of 1 db."
::= { sraShiftMarginProfileEntry 2 }
xtucConfUpshiftSnrMgn OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the downstream SRA UP Shift Margin in units of 0.25 dB, for a range of 0 to 31.75 dB. in unit of 1 db."
::= { sraShiftMarginProfileEntry 3 }
xtucConfDownshiftTime OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the downstream SRA Down Shift time in units of 1 sec , for a range of 0 to 16383 sec. in unit of 1 sec."
::= { sraShiftMarginProfileEntry 4 }
xtucConfUpshiftTime OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the downstream SRA UP Shift time in units of 1 sec , for a range of 0 to 16383 sec. in unit of 1 sec."
::= { sraShiftMarginProfileEntry 5 }
xturConfDownshiftSnrMgn OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the upstream SRA Down Shift Margin in units of 0.25 dB, for a range of 0 to 31.75 dB. in unit of 1 db."
::= { sraShiftMarginProfileEntry 6 }
xturConfUpshiftSnrMgn OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the upstream SRA UP Shift Margin in units of 0.25 dB, for a range of 0 to 31.75 dB. in unit of 1 db."
::= { sraShiftMarginProfileEntry 7 }
xturConfDownshiftTime OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the upstream SRA Down Shift time in units of 1 sec , for a range of 0 to 16383 sec. in unit of 1 sec."
::= { sraShiftMarginProfileEntry 8 }
xturConfUpshiftTime OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the upstream SRA UP Shift time in units of 1 sec , for a range of 0 to 16383 sec. in unit of 1 sec."
::= { sraShiftMarginProfileEntry 9 }
sraShiftMarginProfileStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or modify or delete an existing row in this table."
::= { sraShiftMarginProfileEntry 10 }
--------------------
-- ipqosProfile
--------------------
-- ipqosProfileTable
maxNumOfIpqosProfiles OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of IPQOS profiles supported by the system."
::= { ipqosProfile 1 }
ipqosProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpqosProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes IPQOS related configuration."
::= { ipqosProfile 2 }
ipqosProfileEntry OBJECT-TYPE
SYNTAX IpqosProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in ipqosProfileTable."
INDEX { ipqosProfileName , ipqosProfileNumOfQueue }
::= { ipqosProfileTable 1 }
IpqosProfileEntry ::=
SEQUENCE {
ipqosProfileName DisplayString,
ipqosProfileNumOfQueue INTEGER,
ipqosProfileRowStatus RowStatus
}
ipqosProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used by the IPQOS profile table in order to identify a row of this table."
::= { ipqosProfileEntry 1 }
ipqosProfileNumOfQueue OBJECT-TYPE
SYNTAX INTEGER (1..8)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of IPQOS queues."
::= { ipqosProfileEntry 2 }
ipqosProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in the table."
::= { ipqosProfileEntry 3 }
-- ipqosProfileQueueTable
ipqosProfileQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpqosProfileQueueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes IPQOS queue related configuration."
::= { ipqosProfile 3 }
ipqosProfileQueueEntry OBJECT-TYPE
SYNTAX IpqosProfileQueueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in ipqosProfileQueueTable."
INDEX { ipqosProfileName , ipqosProfileQueueIndex }
::= { ipqosProfileQueueTable 1 }
IpqosProfileQueueEntry ::=
SEQUENCE {
ipqosProfileQueueIndex INTEGER,
ipqosProfileQueuePIR INTEGER,
ipqosProfileQueueCIR INTEGER,
ipqosProfileQueuePBS INTEGER,
ipqosProfileQueueCBS INTEGER,
ipqosProfileQueueLevel INTEGER,
ipqosProfileQueueWeight INTEGER
}
ipqosProfileQueueIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IPQOS queue index."
::= { ipqosProfileQueueEntry 1 }
ipqosProfileQueuePIR OBJECT-TYPE
SYNTAX INTEGER (512..131072)
UNITS "Kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Peak rate.(multiple of 256)"
::= { ipqosProfileQueueEntry 2 }
ipqosProfileQueueCIR OBJECT-TYPE
SYNTAX INTEGER (256..65536)
UNITS "Kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Commited rate.(multiple of 256)"
::= { ipqosProfileQueueEntry 3 }
ipqosProfileQueuePBS OBJECT-TYPE
SYNTAX INTEGER (3072..65536)
UNITS "byte"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Peak burst size.(mutiple of 256)"
::= { ipqosProfileQueueEntry 4 }
ipqosProfileQueueCBS OBJECT-TYPE
SYNTAX INTEGER (3072..65536)
UNITS "byts"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Commited burst size.(mutiple of 256)"
::= { ipqosProfileQueueEntry 5 }
ipqosProfileQueueLevel OBJECT-TYPE
SYNTAX INTEGER (0..7)
UNITS "byts"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Queue level."
::= { ipqosProfileQueueEntry 6 }
ipqosProfileQueueWeight OBJECT-TYPE
SYNTAX INTEGER (1..127)
UNITS "byts"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Queue weight."
::= { ipqosProfileQueueEntry 7 }
----------------------------------------
-- switch
----------------------------------------
dot3ad OBJECT IDENTIFIER ::= { switch 6 }
dscp OBJECT IDENTIFIER ::= { switch 10 }
vlanIsolation OBJECT IDENTIFIER ::= { switch 12 }
enetMtu OBJECT IDENTIFIER ::= { switch 13 }
tpid OBJECT IDENTIFIER ::= { switch 14 }
cfm OBJECT IDENTIFIER ::= { switch 15 }
-- Standalone IP DSLAM puts all ACL features in 'switch', from OID 51
dhcp OBJECT IDENTIFIER ::= { switch 51 }
macfilter OBJECT IDENTIFIER ::= { switch 53 }
dhcpSnoop OBJECT IDENTIFIER ::= { switch 55 }
acl OBJECT IDENTIFIER ::= { switch 56 }
pppoeAgent OBJECT IDENTIFIER ::= { switch 57 }
n1mac OBJECT IDENTIFIER ::= { switch 58 }
macff OBJECT IDENTIFIER ::= { switch 60 }
--------------------
-- dot3ad
--------------------
dot3adTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot3adEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table contains 802.3ad configuration."
::= { dot3ad 1 }
dot3adEntry OBJECT-TYPE
SYNTAX Dot3adEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { dot3adGroupId }
::= { dot3adTable 1 }
Dot3adEntry ::=
SEQUENCE {
dot3adGroupId INTEGER,
dot3adEnable INTEGER
}
dot3adGroupId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Group ID 1 for the subtending group and 2 for the uplink group."
::= { dot3adEntry 1 }
dot3adEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
enableWithLacp(2),
disable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable 802.3ad function."
::= { dot3adEntry 2 }
lacpPriority OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"LACP system priority."
::= { dot3ad 2 }
lacpTimeout OBJECT-TYPE
SYNTAX INTEGER {
shorttimeout(1),
longtimeout(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time interval to exchange LACP packets in order to check that the peer port
in the trunk group is still up."
::= { dot3ad 3 }
portTrunkingTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortTrunkingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table contains current status of port trunking."
::= { dot3ad 4 }
portTrunkingEntry OBJECT-TYPE
SYNTAX PortTrunkingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { portTrunkingGroupId }
::= { portTrunkingTable 1 }
PortTrunkingEntry ::=
SEQUENCE {
portTrunkingGroupId INTEGER,
portTrunkingStatus INTEGER,
portTrunkingPortList PortList
}
portTrunkingGroupId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Group ID 1 for the subtending group and 2 for the uplink group."
::= { portTrunkingEntry 1 }
portTrunkingStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port trunking status."
::= { portTrunkingEntry 2 }
portTrunkingPortList OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port list which actually joins the trunking group."
::= { portTrunkingEntry 3 }
--------------------
-- dscp
--------------------
dscpMappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF DscpMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table contains DSCP mapping configuration for the adsl ports."
::= { dscp 1 }
dscpMappingEntry OBJECT-TYPE
SYNTAX DscpMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dscpMappingTable."
INDEX { dscpSrcCodePoint }
::= { dscpMappingTable 1 }
DscpMappingEntry ::=
SEQUENCE {
dscpSrcCodePoint INTEGER,
-- dscpMapCodePoint INTEGER,
dscpMapPriority INTEGER
}
dscpSrcCodePoint OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DSCP source code point used for mapping."
::= { dscpMappingEntry 1 }
-- dscpMapCodePoint OBJECT-TYPE
-- SYNTAX INTEGER (0..63)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The mapping code point that will replace the source code point in the incoming packet."
-- ::= { dscpMappingEntry 2 }
dscpMapPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mapping p bits that will replace the source p bits in the incoming packet."
::= { dscpMappingEntry 3 }
--- pfchen
dscpPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF DscpPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table contains DSCP mapping configuration for the adsl ports."
::= { dscp 2 }
dscpPortEntry OBJECT-TYPE
SYNTAX DscpPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dscpPortTable."
INDEX { ifIndex }
::= { dscpPortTable 1 }
DscpPortEntry ::=
SEQUENCE {
dscpStatusEnable INTEGER
}
dscpStatusEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DSCP port status."
::= { dscpPortEntry 1 }
--------------------
-- Vlan Isolation
--------------------
vlanIsolationTable OBJECT-TYPE
SYNTAX SEQUENCE OF VlanIsolationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table contains configuration of isolated VLAN."
::= { vlanIsolation 1 }
vlanIsolationEntry OBJECT-TYPE
SYNTAX VlanIsolationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of vlanIsolationTable."
INDEX { dot1qVlanIndex }
::= { vlanIsolationTable 1 }
VlanIsolationEntry ::=
SEQUENCE {
vlanIsolationRowStatus INTEGER
}
vlanIsolationRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status of the table used to create/delete an entry."
::= { vlanIsolationEntry 1 }
--------------------
-- enet MTU
--------------------
enetMtuEntry OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the MTU size for layer 2 frame, size from 1526 to 1532, default value is 1526."
::= { enetMtu 1 }
--------------------
-- TPID (Tag Protocol Identifier)
--------------------
tpidEntry OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets TPID(Tag Protocol Identifier) of tagged frame, 0~FFFF."
::= { tpid 1 }
--------------------
-- CFM
--------------------
-- cfmLoopbackPortTable
cfmLoopbackPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfmLoopbackPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains CFM information."
::= { cfm 1 }
cfmLoopbackPortEntry OBJECT-TYPE
SYNTAX CfmLoopbackPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in cfmLoopbackPortTable."
INDEX { ifIndex }
::= { cfmLoopbackPortTable 1 }
CfmLoopbackPortEntry ::= SEQUENCE {
cfmLoopbackPortState INTEGER
}
cfmLoopbackPortState OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CFM loopback enable/disable on the port."
::= { cfmLoopbackPortEntry 1 }
-- cfmMIPTable
cfmMIPTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfmMIPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { cfm 2 }
cfmMIPEntry OBJECT-TYPE
SYNTAX CfmMIPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in cfmMIPTable."
INDEX { dot1agCfmMdIndex, cfmPort }
::= { cfmMIPTable 1 }
CfmMIPEntry ::=
SEQUENCE {
cfmPort INTEGER,
cfmMIPRowStatus RowStatus,
cfmMIPMacAddr PhysAddress
}
-- cfmLevel OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { cfmMIPEntry 1 }
--
-- cfmVlanID OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { cfmMIPEntry 2 }
cfmPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { cfmMIPEntry 3 }
cfmMIPRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
""
::= { cfmMIPEntry 4 }
cfmMIPMacAddr OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CFM MIP mac address"
::= { cfmMIPEntry 5 }
cfmActionEnableStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CFM Action enable status for the CO device"
::= { cfm 3 }
cfmMode OBJECT-TYPE
SYNTAX INTEGER {
mode802Dot1Ag(1),
modeYDot1731(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CFM follow standard mode"
::= { cfm 4 }
cfmLbmTimeout OBJECT-TYPE
SYNTAX INTEGER (100..86400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CFM LBM timeout, 100-86400 ms"
::= { cfm 5 }
cfmLbmDataTlvLength OBJECT-TYPE
SYNTAX INTEGER (0..1400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CFM LBM data tlv length, 0-1400 bytes"
::= { cfm 6 }
-- cfmLbrTable
cfmLbrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfmLbrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains CFM LBR results."
::= { cfm 7 }
cfmLbrEntry OBJECT-TYPE
SYNTAX CfmLbrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in cfmLbrTable."
INDEX { dot1agCfmMdIndex, dot1agCfmMaIndex, dot1agCfmMepIdentifier, cfmLbmIndex, cfmLbrIndex}
::= { cfmLbrTable 1 }
CfmLbrEntry ::= SEQUENCE {
cfmLbmIndex INTEGER,
cfmLbrIndex INTEGER,
cfmLbrSrcMac PhysAddress,
cfmLbrStatus INTEGER,
cfmLbrRtt INTEGER
}
cfmLbmIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CFM lbm index."
::= { cfmLbrEntry 1 }
cfmLbrIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CFM lbr index."
::= { cfmLbrEntry 2 }
cfmLbrSrcMac OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CFM lbr source address."
::= { cfmLbrEntry 3 }
cfmLbrStatus OBJECT-TYPE
SYNTAX INTEGER {
ready(1),
notready(2),
xmit(3),
success(4),
timeout(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CFM lbr status."
::= { cfmLbrEntry 4 }
cfmLbrRtt OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CFM lbr rtt in ms."
::= { cfmLbrEntry 5 }
--------------------
-- DHCP Relay
--------------------
dhcpRelay82Table OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpRelay82Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains DHCP Relay configuration."
::= { dhcp 2 }
dhcpRelay82Entry OBJECT-TYPE
SYNTAX DhcpRelay82Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of DHCP Relay table."
INDEX { dot1qVlanIndex }
::= { dhcpRelay82Table 1 }
DhcpRelay82Entry ::=
SEQUENCE {
dhcpRelay82PrimaryServer IpAddress,
dhcpRelay82SecondaryServer IpAddress,
dhcpRelay82ActiveServer INTEGER,
dhcpRelay82Enable INTEGER,
dhcpRelay82Info DisplayString,
dhcpRelay82RelayMode INTEGER,
dhcpRelay82Suboption2Enable INTEGER,
dhcpRelay82Suboption2Info DisplayString,
dhcpRelay82EntryEnable INTEGER,
dhcpRelay82EntryOptionMode INTEGER,
dhcpRelay82VlanIp IpAddress,
dhcpRelay82VlanMask INTEGER,
dhcpRelay82VlanGateway IpAddress,
dhcpRelay82ThirdServer IpAddress,
dhcpRelay82FourthServer IpAddress,
dhcpRelay82FifthServer IpAddress,
dhcpRelay82ServerVid INTEGER
}
dhcpRelay82PrimaryServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the DHCP Relay primary server."
::= { dhcpRelay82Entry 1 }
dhcpRelay82SecondaryServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the DHCP Relay secondary server."
::= { dhcpRelay82Entry 2 }
dhcpRelay82ActiveServer OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
secondary(2),
third(3),
fourth(4),
fifth(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current active DHCP Relay server."
::= { dhcpRelay82Entry 3 }
dhcpRelay82Enable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/disable DHCP relay and Option82 function."
::= { dhcpRelay82Entry 4 }
dhcpRelay82Info OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..23))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"User specific Option82 information."
::= { dhcpRelay82Entry 5 }
dhcpRelay82RelayMode OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
all(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"DHCP relay mode."
::= { dhcpRelay82Entry 6 }
dhcpRelay82Suboption2Enable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/disable Option 82 sub-option 2."
::= { dhcpRelay82Entry 8 }
dhcpRelay82Suboption2Info OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"User specified information for Option 82 sub-option 2."
::= { dhcpRelay82Entry 9 }
dhcpRelay82EntryEnable OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
all(2),
disable(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/disable DHCP Relay"
::= { dhcpRelay82Entry 10 }
dhcpRelay82EntryOptionMode OBJECT-TYPE
SYNTAX INTEGER {
private(1),
tr101(2),
customer-remote-id(3),
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Option82 format."
::= { dhcpRelay82Entry 11 }
dhcpRelay82VlanIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the DHCP Relay interface for this VLAN."
::= { dhcpRelay82Entry 12 }
dhcpRelay82VlanMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The network mask of the DHCP Relay interface for this VLAN."
::= { dhcpRelay82Entry 13 }
dhcpRelay82VlanGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gateway of the DHCP Relay interface for this VLAN."
::= { dhcpRelay82Entry 14 }
dhcpRelay82ThirdServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the DHCP Relay third server."
::= { dhcpRelay82Entry 15 }
dhcpRelay82FourthServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the DHCP Relay fourth server."
::= { dhcpRelay82Entry 16 }
dhcpRelay82FifthServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the DHCP Relay fifth server."
::= { dhcpRelay82Entry 17 }
dhcpRelay82ServerVid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The VID of the DHCP Relay server for this VLAN."
::= { dhcpRelay82Entry 18 }
-- dhcpRelayTest
dhcpRelayTest OBJECT IDENTIFIER ::= { dhcp 8 }
dhcpRelayTestVid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the VID of the test server."
::= { dhcpRelayTest 1 }
dhcpRelayTestIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the IP of the test server."
::= { dhcpRelayTest 2 }
dhcpRelayTestOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the object to 1 to test DHCP server."
::= { dhcpRelayTest 3 }
dhcpRelayTestStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display testing server status."
::= { dhcpRelayTest 4 }
-- dhcpRelayArp
dhcpRelayArp OBJECT IDENTIFIER ::= { dhcp 9 }
dhcpRelayArpShowTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpRelayArpShowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table displays DHCP ARP."
::= { dhcpRelayArp 1 }
dhcpRelayArpShowEntry OBJECT-TYPE
SYNTAX DhcpRelayArpShowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dhcpRelayArpShowTable."
INDEX { dhcpRelayArpShowVid, dhcpRelayArpShowIp }
::= { dhcpRelayArpShowTable 1 }
DhcpRelayArpShowEntry ::=
SEQUENCE {
dhcpRelayArpShowVid INTEGER,
dhcpRelayArpShowIp IpAddress,
dhcpRelayArpShowMac PhysAddress
}
dhcpRelayArpShowVid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display the VID of the DHCP ARP entry."
::= { dhcpRelayArpShowEntry 1 }
dhcpRelayArpShowIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display the IP of the DHCP ARP entry."
::= { dhcpRelayArpShowEntry 2 }
dhcpRelayArpShowMac OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display the MAC of the DHCP ARP entry."
::= { dhcpRelayArpShowEntry 3 }
dhcpRelayArpFlushOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the object to 1 to start flushing."
::= { dhcpRelayArp 2 }
--------------------
-- MAC Filter
--------------------
-- MAC Filter Port Table
macFilterPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFilterPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes the status of mac filtering for each port."
::= { macfilter 1 }
macFilterPortEntry OBJECT-TYPE
SYNTAX MacFilterPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in macFilterPortTable."
INDEX { ifIndex }
::= { macFilterPortTable 1 }
MacFilterPortEntry ::=
SEQUENCE {
macFilterPortEnable INTEGER,
macFilterPortMacCount INTEGER,
macFilterPortFilterMode INTEGER
}
macFilterPortEnable OBJECT-TYPE
SYNTAX INTEGER {
enableMacFilter(1),
enableMacCount(2),
-- enableOuiFilter(3),
disable(4),
enableMacFilterAndMacCount(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable MAC filtering for the port."
::= { macFilterPortEntry 1 }
macFilterPortMacCount OBJECT-TYPE
SYNTAX INTEGER (1..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The total number of MAC addresses allowed for the port."
::= { macFilterPortEntry 2 }
macFilterPortFilterMode OBJECT-TYPE
SYNTAX INTEGER {
accept(1),
deny(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mac filter mode (accept or deny) for the port."
::= { macFilterPortEntry 3 }
maxNumOfMacFiltersInSystem OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max number of mac filters supported in the system."
::= { macfilter 2 }
maxNumOfMacFiltersPerPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max number of mac filters supported per port."
::= { macfilter 3 }
currNumOfMacFiltersInSystem OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of mac filters in the system."
::= { macfilter 4 }
-- MAC Table
macFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains the mac filter addresses."
::= { macfilter 5 }
macFilterEntry OBJECT-TYPE
SYNTAX MacFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of macFilterTable."
INDEX { ifIndex, macFilterAddr }
::= { macFilterTable 1 }
MacFilterEntry ::=
SEQUENCE {
macFilterAddr PhysAddress,
macFilterRowStatus RowStatus
}
macFilterAddr OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mac address which can pass through or be rejected from the port."
::= { macFilterEntry 1 }
macFilterRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of the entry."
::= { macFilterEntry 2 }
-- Batch Set for MAC Filter
macfilterBatchSet OBJECT IDENTIFIER ::= { macfilter 6 }
macfilterTarget OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This managed object is used for identify the target on which
the port configuration should be performed. The target is encoded as:
Byte 1: 0, Reserved(chassis)
Byte 2~3: 0, Reserved(slot)
Byte 4: 0, reserved
Byte 5~11:each octet specifies a set of eight ports, with the first
octet specifying ports 1 through 8, etc."
::= { macfilterBatchSet 1 }
macfilterOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The corresponding bit is set to 1 to start the operation.
The various bit positions are:
BIT 1: enable mac filter
BIT 2: enable mac count filter
BIT 3: disable mac filter
BIT 4: set mac count
BIT 5: disable mac count filter."
::= { macfilterBatchSet 2 }
macFilterMacCountForBatchSet OBJECT-TYPE
SYNTAX INTEGER (1..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The total number of MAC addresses allowed for a port."
::= { macfilterBatchSet 3 }
-- OUI Filter Table
ouiFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF OuiFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains the OUI filter addresses."
::= { macfilter 7 }
ouiFilterEntry OBJECT-TYPE
SYNTAX OuiFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of ouiFilterTable."
INDEX { ifIndex, ouiFilterAddr }
::= { ouiFilterTable 1 }
OuiFilterEntry ::=
SEQUENCE {
ouiFilterAddr OCTET STRING,
ouiFilterRowStatus RowStatus
}
ouiFilterAddr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The first three bytes of the mac address which can pass through or be rejected from the port."
::= { ouiFilterEntry 1 }
ouiFilterRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of the entry."
::= { ouiFilterEntry 2 }
maxNumOfOuiFiltersPerPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max number of OUI filters supported per port."
::= { macfilter 8 }
ouiFilterPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF OuiFilterPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes the status of oui filtering for each port."
::= { macfilter 9 }
ouiFilterPortEntry OBJECT-TYPE
SYNTAX OuiFilterPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in macFilterPortTable."
INDEX { ifIndex }
::= { ouiFilterPortTable 1 }
OuiFilterPortEntry ::=
SEQUENCE {
ouiFilterPortEnable INTEGER,
ouiFilterPortFilterMode INTEGER
}
ouiFilterPortEnable OBJECT-TYPE
SYNTAX INTEGER {
enableOuiFilter(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable oui filtering for the port."
::= { ouiFilterPortEntry 1 }
ouiFilterPortFilterMode OBJECT-TYPE
SYNTAX INTEGER {
accept(1),
deny(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The oui filter mode (accept or deny) for the port."
::= { ouiFilterPortEntry 2 }
--------------------
-- DHCP Snoop
--------------------
-- dhcpSnoopPortTable
dhcpSnoopPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpSnoopPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes DHCP snooping enable/disable for each port."
::= { dhcpSnoop 1 }
dhcpSnoopPortEntry OBJECT-TYPE
SYNTAX DhcpSnoopPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dhcpSnoopPortTable."
INDEX { ifIndex }
::= { dhcpSnoopPortTable 1 }
DhcpSnoopPortEntry ::=
SEQUENCE {
dhcpSnoopEnable INTEGER,
dhcpSnoopMaxcnt INTEGER,
dhcpSnoopSmacverifyEnable INTEGER
}
dhcpSnoopEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable DHCP snooping for a port."
::= { dhcpSnoopPortEntry 1 }
dhcpSnoopMaxcnt OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the max entries of the DHCP ARP table."
::= { dhcpSnoopPortEntry 2 }
dhcpSnoopSmacverifyEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable DHCP source MAC verify for a port."
::= { dhcpSnoopPortEntry 3 }
-- dhcpSnoopOperation
dhcpSnoopTarget OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This managed object is used for identify the target on which
the operation should be performed. The target is encoded as:
Byte 1: the octet specifies a set of eight chassis, chassis 0 through 7
Byte 2~3: each octet specifies a set of eight slots, with the
first octet specifying slots 1 through 8 and the second
octet specifying slots 9 through 16.
Byte 4: reserved
Byte 5~11:each octet specifies a set of eight ports, with the first
octet specifying ports 1 through 8, etc."
::= { dhcpSnoop 2 }
dhcpSnoopOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The corresponding bit is set to 1 to start the operation.
The various bit positions are:
BIT 1: DHCP snooping table flush."
::= { dhcpSnoop 3 }
-- dhcpStaticTable
dhcpStaticTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpStaticEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines DHCP static IP addresses."
::= { dhcpSnoop 4 }
dhcpStaticEntry OBJECT-TYPE
SYNTAX DhcpStaticEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dhcpStaticTable."
INDEX { ifIndex, dhcpStaticIpAddr }
::= { dhcpStaticTable 1 }
DhcpStaticEntry ::=
SEQUENCE {
dhcpStaticIpAddr IpAddress,
dhcpStaticRowStatus RowStatus
}
dhcpStaticIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address which can pass through the port."
::= { dhcpStaticEntry 1 }
dhcpStaticRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status of the table entry."
::= { dhcpStaticEntry 2 }
maxNumOfDhcpStaticIp OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of DHCP static IP addresses which can be created for a port."
::= { dhcpSnoop 5 }
dhcpSnoopMaxcntMode OBJECT-TYPE
SYNTAX INTEGER {
replace(1),
drop(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When DHCP snooping table is full, new DHCP lease will replace first one in option 0 or will be dropped in option 1."
::= { dhcpSnoop 6 }
--------------------
-- ACL Rule
--------------------
-- aclSetTable
aclSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF AclSetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"aclsetTable."
::= { acl 1 }
aclSetEntry OBJECT-TYPE
SYNTAX AclSetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of aclSetTable."
INDEX { ifIndex, aclSetVpi, aclSetVci, aclSetProfileName }
::= { aclSetTable 1 }
AclSetEntry ::=
SEQUENCE {
aclSetVpi INTEGER,
aclSetVci INTEGER,
aclSetProfileName DisplayString,
aclSetRowStatus RowStatus
}
aclSetVpi OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI value"
::= { aclSetEntry 1 }
aclSetVci OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI value"
::= { aclSetEntry 2 }
aclSetProfileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ACL Profile name"
::= { aclSetEntry 3 }
aclSetRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus of aclSetEntry"
::= { aclSetEntry 4 }
-- aclProfileTable
aclProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF AclProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"aclProfileTable."
::= { acl 2 }
aclProfileEntry OBJECT-TYPE
SYNTAX AclProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of aclProfileTable."
INDEX { aclProfileRuleName }
::= { aclProfileTable 1 }
AclProfileEntry ::=
SEQUENCE {
aclProfileRuleName DisplayString,
aclProfileRuleNumber INTEGER,
aclProfileActionNumber INTEGER,
aclProfileRuleParamMask INTEGER,
aclProfileRuleEtype INTEGER,
aclProfileRuleVid INTEGER,
aclProfileRuleSmac PhysAddress,
aclProfileRuleDmac PhysAddress,
aclProfileRulePriority INTEGER,
aclProfileRuleProtocol INTEGER,
-- aclProfileRuleSrcIP IpAddress,
-- aclProfileRuleSrcIPMask INTEGER,
-- aclProfileRuleDestIP IpAddress,
-- aclProfileRuleDestIPMask INTEGER,
-- aclProfileRuleStartTos INTEGER,
-- aclProfileRuleEndTos INTEGER,
-- aclProfileRuleSrcStartPort INTEGER,
-- aclProfileRuleSrcEndPort INTEGER,
-- aclProfileRuleDestStartPort INTEGER,
-- aclProfileRuleDestEndPort INTEGER,
aclProfileActionRate INTEGER,
aclProfileActionrvlan INTEGER,
aclProfileActionrpri INTEGER,
aclProfileRowStatus RowStatus,
aclProfileRuleSip IpAddress,
aclProfileRuleDip IpAddress,
aclProfileRuleSport INTEGER,
aclProfileRuleDport INTEGER
}
aclProfileRuleName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Profile rule name"
::= { aclProfileEntry 1 }
aclProfileRuleNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The managed object is for acl profile rule configuration.
etype <etype> vlan <vid> (1),
etype <etype> smac <mac> (2),
etype <etype> dmac <mac> (3),
vlan <vid> smac <mac> (4),
vlan <vid> dmac <mac> (5),
smac <mac> dmac <mac> (6),
vlan <vid> priority <priority> (7),
etype <etype> (8),
vlan <vid> (9),
smac <mac> (10),
dmac <mac> (11),
priority <priority> (12),
protocol <protocol> (13),
vlan <vid> sip <ip> (14),
vlan <vid> dip <ip> (15),
vlan <vid> sport tcp|udp <port> (16),
vlan <vid> dport tcp|udp <port> (17) "
::= { aclProfileEntry 2 }
aclProfileActionNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile action number.
Bit 1: rate
Bit 2: rvlan
Bit 3: rpri
Bit 4: deny
Bit 1, Bit 2 & Bit 3 can multiple selection."
::= { aclProfileEntry 3 }
aclProfileRuleParamMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile rule parameter mask.
BIT 1: srcip <ip>/<mask>
BIT 2: dstip <ip>/<mask>
BIT 3: tos <stos> <etos>
BIT 4: srcport <sport> <eport>
BIT 5: dstport <sport> <eport>"
::= { aclProfileEntry 4 }
aclProfileRuleEtype OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile rule etype"
::= { aclProfileEntry 5 }
aclProfileRuleVid OBJECT-TYPE
SYNTAX INTEGER (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile rule vid"
::= { aclProfileEntry 6 }
aclProfileRuleSmac OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile rule source MAC"
::= { aclProfileEntry 7 }
aclProfileRuleDmac OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile rule destination MAC"
::= { aclProfileEntry 8 }
aclProfileRulePriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile rule priority"
::= { aclProfileEntry 9 }
aclProfileRuleProtocol OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile rule protocol.
icmp(1),igmp(2),ip(4),tcp(6),
udp(17),gre(47),ospf(89),
other ptype"
::= { aclProfileEntry 10 }
-- aclProfileRuleSrcIP OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Profile rule source IP"
-- ::= { aclProfileEntry 11 }
--
-- aclProfileRuleSrcIPMask OBJECT-TYPE
-- SYNTAX INTEGER (0..32)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The subnet mask of source IP mask"
-- ::= { aclProfileEntry 12 }
--
-- aclProfileRuleDestIP OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Profile rule source IP"
-- ::= { aclProfileEntry 13 }
--
-- aclProfileRuleDestIPMask OBJECT-TYPE
-- SYNTAX INTEGER (0..32)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The subnet mask of dest IP mask"
-- ::= { aclProfileEntry 14 }
--
-- aclProfileRuleStartTos OBJECT-TYPE
-- SYNTAX INTEGER (0..255)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Profile rule start type of service"
-- ::= { aclProfileEntry 15 }
--
-- aclProfileRuleEndTos OBJECT-TYPE
-- SYNTAX INTEGER (0..255)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Profile rule end type of service"
-- ::= { aclProfileEntry 16 }
--
-- aclProfileRuleSrcStartPort OBJECT-TYPE
-- SYNTAX INTEGER (0..65535)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Profile rule source start port"
-- ::= { aclProfileEntry 17 }
--
-- aclProfileRuleSrcEndPort OBJECT-TYPE
-- SYNTAX INTEGER (0..65535)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Profile rule source end port"
-- ::= { aclProfileEntry 18 }
--
-- aclProfileRuleDestStartPort OBJECT-TYPE
-- SYNTAX INTEGER (0..65535)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Profile rule destination start port"
-- ::= { aclProfileEntry 19 }
--
-- aclProfileRuleDestEndPort OBJECT-TYPE
-- SYNTAX INTEGER (0..65535)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Profile rule destination end port"
-- ::= { aclProfileEntry 20 }
aclProfileActionRate OBJECT-TYPE
SYNTAX INTEGER (32..65472)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile action to replace to this rate"
::= { aclProfileEntry 21 }
aclProfileActionrvlan OBJECT-TYPE
SYNTAX INTEGER (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile action to replace to this vlan"
::= { aclProfileEntry 22 }
aclProfileActionrpri OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile action to replace to this priority"
::= { aclProfileEntry 23 }
aclProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The row status of the entry."
::= { aclProfileEntry 24 }
aclProfileRuleSip OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Source IP."
::= { aclProfileEntry 25 }
aclProfileRuleDip OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Destination IP."
::= { aclProfileEntry 26 }
aclProfileRuleSport OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Source port."
::= { aclProfileEntry 27 }
aclProfileRuleDport OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Destination port."
::= { aclProfileEntry 28 }
--------------------
-- PPPoE Agent
--------------------
-- pppoeAgentTable
pppoeAgentTable OBJECT-TYPE
SYNTAX SEQUENCE OF PppoeAgentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains PPPoE intermediate agent configuration."
::= { pppoeAgent 1 }
pppoeAgentEntry OBJECT-TYPE
SYNTAX PppoeAgentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of pppoeAgentTable."
INDEX { dot1qVlanIndex }
::= { pppoeAgentTable 1 }
PppoeAgentEntry ::=
SEQUENCE {
pppoeAgentEnable INTEGER,
pppoeAgentInfo DisplayString,
pppoeAgentRowStatus RowStatus,
pppoeAgentOptionMode INTEGER
}
pppoeAgentEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/disable PppoE intermediate agent function."
::= { pppoeAgentEntry 1 }
pppoeAgentInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..23))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"User specific Option82 information."
::= { pppoeAgentEntry 2 }
pppoeAgentRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status of the table entry."
::= { pppoeAgentEntry 3 }
pppoeAgentOptionMode OBJECT-TYPE
SYNTAX INTEGER {
private(1),
tr101(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Option82 format."
::= { pppoeAgentEntry 4 }
maxNumOfPppoeAgentConf OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of rows that can be created in pppoeAgentTable."
::= { pppoeAgent 2 }
--------------------
-- n1mac
--------------------
n1macReplaceMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This MAC address will be used to replace client's MAC address."
::= { n1mac 1 }
n1macPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF N1macPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table contains N to 1 MAC configuration for DSL ports."
::= { n1mac 2 }
n1macPortEntry OBJECT-TYPE
SYNTAX N1macPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of n1macPortTable."
INDEX { ifIndex }
::= { n1macPortTable 1 }
N1macPortEntry ::=
SEQUENCE {
n1macStatusEnable INTEGER
}
n1macStatusEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port status of n1mac function."
::= { n1macPortEntry 1 }
----------------------------------------
-- macff
----------------------------------------
macFfTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains MAC Force Forwarding configuration."
::= { macff 1 }
macFfEntry OBJECT-TYPE
SYNTAX MacFfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of macFfTable."
INDEX { macFfIndex }
::= { macFfTable 1 }
MacFfEntry ::=
SEQUENCE {
macFfIndex INTEGER,
macFfVid INTEGER,
macFfArIP IpAddress,
-- macFfArMask INTEGER,
macFfSrcIP IpAddress,
macFfSrcMask INTEGER,
macFfRowStatus RowStatus
}
macFfIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the MACFF."
::= { macFfEntry 1 }
macFfVid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The VLAN-ID refering to this AR/AS."
::= { macFfEntry 2 }
macFfArIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP of this AR/AS"
::= { macFfEntry 3 }
macFfSrcIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The source IP address of the MACFF."
::= { macFfEntry 4 }
macFfSrcMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The subnet mask of source IP mask."
::= { macFfEntry 5 }
macFfRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of the MacFfEntry entry."
::= { macFfEntry 6 }
macFfArpFlush OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the object to 1 to flush mac table."
::= { macff 3 }
maxNumOfMacFfVlanInSystem OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max number of macff Vlans supported in the system."
::= { macff 4 }
macFfVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFfVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains MAC Force Forwarding Vlan configuration."
::= { macff 5 }
macFfVlanEntry OBJECT-TYPE
SYNTAX MacFfVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of macFfVlanTable."
INDEX { dot1qVlanIndex }
::= { macFfVlanTable 1 }
MacFfVlanEntry ::=
SEQUENCE {
macFfVlanRowstatus INTEGER
-- macFfVlanUnknownUnicast INTEGER removed since R3.1
}
macFfVlanRowstatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status of the table used to create/delete an entry."
::= { macFfVlanEntry 1 }
-- removed since R3.1
-- macFfVlanUnknownUnicast OBJECT-TYPE
-- SYNTAX INTEGER {
-- flood(1),
-- drop(2)
-- }
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "Setting downstream unknown uni-cast packet on macff vlan to flooding or dropping."
-- ::= { macFfVlanEntry 2 }
macFfStaticIPTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFfStaticIPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" "
::= { macff 6 }
macFfStaticIPEntry OBJECT-TYPE
SYNTAX MacFfStaticIPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of macFfTable."
INDEX { macFfStaticIPPort, macFfStaticIPVid, macFfstaticIP , macFfStaticIPMask}
::= { macFfStaticIPTable 1 }
MacFfStaticIPEntry ::=
SEQUENCE {
macFfStaticIPPort INTEGER,
macFfStaticIPVid INTEGER,
macFfstaticIP IpAddress,
macFfStaticIPMask INTEGER,
macFfStaticIPRowStatus RowStatus
}
macFfStaticIPPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The port number, 1 ~ 48."
::= { macFfStaticIPEntry 1 }
macFfStaticIPVid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VLAN ID of the IP range, 1 ~ 4094, the vid should be enable the MACFF function first."
::= { macFfStaticIPEntry 2 }
macFfstaticIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The specified IP range."
::= { macFfStaticIPEntry 3 }
macFfStaticIPMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mask_bits is 24 .. 32."
::= { macFfStaticIPEntry 4 }
macFfStaticIPRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status used to configure the table entry."
::= { macFfStaticIPEntry 5 }
-- Server Mac --
macFfServerMacTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFfServerMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" "
::= { macff 7 }
macFfServerMacEntry OBJECT-TYPE
SYNTAX MacFfServerMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of macFfTable."
INDEX { macFfServerMacVid, macFfServerMacAddr}
::= { macFfServerMacTable 1 }
MacFfServerMacEntry ::=
SEQUENCE {
macFfServerMacVid INTEGER,
macFfServerMacAddr PhysAddress,
macFfServerMacRowStatus RowStatus
}
macFfServerMacVid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VLAN ID of the IP range, 1 ~ 4094, the vid should be enable the MACFF function first."
::= { macFfServerMacEntry 1 }
macFfServerMacAddr OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mac address."
::= { macFfServerMacEntry 2 }
macFfServerMacRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status used to configure the table entry."
::= { macFfServerMacEntry 3 }
----------------------------------------
-- sys
----------------------------------------
timeSetup OBJECT IDENTIFIER ::= { sys 4 }
accessCtrl OBJECT IDENTIFIER ::= { sys 5 }
extAlarm OBJECT IDENTIFIER ::= { sys 8 }
user OBJECT IDENTIFIER ::= { sys 9 }
usbCastCtrl OBJECT IDENTIFIER ::= { sys 10}
dsQos OBJECT IDENTIFIER ::= { sys 11}
fwUpgrade OBJECT IDENTIFIER ::= { sys 14}
delayedReboot OBJECT IDENTIFIER ::= {sys 15}
stdioTimeout OBJECT-TYPE
SYNTAX INTEGER (0..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the stdio timeout, 0~300 minutes."
::= { sys 12 }
isConfigChanged OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If system configuration has been changed."
::= { sys 13 }
--------------------
-- Time Setup
--------------------
-- dayLightSaving
dayLightSaving OBJECT IDENTIFIER ::= { timeSetup 7 }
dayLightSavingAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { dayLightSaving 1 }
dayLightSavingStartTime OBJECT IDENTIFIER ::= { dayLightSaving 2 }
dayLightSavingStartMonth OBJECT-TYPE
SYNTAX INTEGER {
Jan(1),
Feb(2),
Mar(3),
Apr(4),
May(5),
Jun(6),
Jul(7),
Aug(8),
Sep(9),
Oct(10),
Nov(11),
Dec(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { dayLightSavingStartTime 1 }
dayLightSavingStartWeek OBJECT-TYPE
SYNTAX INTEGER {
First(1),
Second(2),
Third(3),
Fourth(4),
Last(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { dayLightSavingStartTime 2 }
dayLightSavingStartWday OBJECT-TYPE
SYNTAX INTEGER {
Sun(1),
Mon(2),
Tus(3),
Wed(4),
Thu(5),
Fri(6),
Sat(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { dayLightSavingStartTime 3 }
dayLightSavingStartHour OBJECT-TYPE
SYNTAX INTEGER {
"0:00"(0),
"1:00"(1),
"2:00"(2),
"3:00"(3),
"4:00"(4),
"5:00"(5),
"6:00"(6),
"7:00"(7),
"8:00"(8),
"9:00"(9),
"10:00"(10),
"11:00"(11),
"12:00"(12),
"13:00"(13),
"14:00"(14),
"15:00"(15),
"16:00"(16),
"17:00"(17),
"18:00"(18),
"19:00"(19),
"20:00"(20),
"21:00"(21),
"22:00"(22),
"23:00"(23),
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"1: 01:00,
2: 02:00
3: 03:00
4: 04:00
5: 05:00
6: 06:00
7: 07:00
8: 08:00
9: 09:00
10: 10:00
11: 11:00
12: 12:00
13: 13:00
14: 14:00
15: 15:00
16: 16:00
17: 17:00
18: 18:00
19: 19:00
20: 20:00
21: 21:00
22: 22:00
23: 23:00"
::= { dayLightSavingStartTime 4 }
dayLightSavingEndTime OBJECT IDENTIFIER ::= { dayLightSaving 3 }
dayLightSavingEndMonth OBJECT-TYPE
SYNTAX INTEGER {
Jan(1),
Feb(2),
Mar(3),
Apr(4),
May(5),
Jun(6),
Jul(7),
Aug(8),
Sep(9),
Oct(10),
Nov(11),
Dec(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { dayLightSavingEndTime 1 }
dayLightSavingEndWeek OBJECT-TYPE
SYNTAX INTEGER {
First(1),
Second(2),
Third(3),
Fourth(4),
Last(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { dayLightSavingEndTime 2 }
dayLightSavingEndWday OBJECT-TYPE
SYNTAX INTEGER {
Sun(1),
Mon(2),
Tus(3),
Wed(4),
Thu(5),
Fri(6),
Sat(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { dayLightSavingEndTime 3 }
dayLightSavingEndHour OBJECT-TYPE
SYNTAX INTEGER {
"0:00"(0),
"1:00"(1),
"2:00"(2),
"3:00"(3),
"4:00"(4),
"5:00"(5),
"6:00"(6),
"7:00"(7),
"8:00"(8),
"9:00"(9),
"10:00"(10),
"11:00"(11),
"12:00"(12),
"13:00"(13),
"14:00"(14),
"15:00"(15),
"16:00"(16),
"17:00"(17),
"18:00"(18),
"19:00"(19),
"20:00"(20),
"21:00"(21),
"22:00"(22),
"23:00"(23),
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"1: 01:00,
2: 02:00
3: 03:00
4: 04:00
5: 05:00
6: 06:00
7: 07:00
8: 08:00
9: 09:00
10: 10:00
11: 11:00
12: 12:00
13: 13:00
14: 14:00
15: 15:00
16: 16:00
17: 17:00
18: 18:00
19: 19:00
20: 20:00
21: 21:00
22: 22:00
23: 23:00"
::= { dayLightSavingEndTime 4 }
--------------------
-- Access Control
--------------------
-- Secured Client Table
securedClientTable OBJECT-TYPE
SYNTAX SEQUENCE OF SecuredClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains information about secured clients."
::= { accessCtrl 2 }
securedClientEntry OBJECT-TYPE
SYNTAX SecuredClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of secured client entry."
INDEX { securedClientIndex }
::= { securedClientTable 1 }
SecuredClientEntry ::=
SEQUENCE {
securedClientIndex INTEGER,
securedClientStartIp IpAddress,
securedClientEndIp IpAddress,
securedClientService INTEGER,
securedClientEnable INTEGER
}
securedClientIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the entry."
::= { securedClientEntry 1 }
securedClientStartIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The starting IP address of the secured client set."
::= { securedClientEntry 2 }
securedClientEndIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ending IP address of the secured client set."
::= { securedClientEntry 3 }
securedClientService OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Each bit corresponds to a service. The bit is set to 1 if the
service is enabled, and set to 0 if the service is disabled.
The various bit positions are:
BIT 1: telnet
BIT 2: ftp
BIT 3: web
BIT 4: icmp
BIT 5: not support
BIT 6: snmp."
::= { securedClientEntry 4 }
securedClientEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable the entry."
::= { securedClientEntry 5 }
--------------------
-- extAlarm
--------------------
extAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExtAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains external alarm information."
::= { extAlarm 1 }
extAlarmEntry OBJECT-TYPE
SYNTAX ExtAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of external alarm table."
INDEX { extAlarmIndex }
::= { extAlarmTable 1 }
ExtAlarmEntry ::=
SEQUENCE {
extAlarmIndex INTEGER,
extAlarmName OCTET STRING,
extAlarmStatus OCTET STRING,
extAlarmTriggeredMode INTEGER
}
extAlarmIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the entry."
::= { extAlarmEntry 1 }
extAlarmName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The external alarm name."
::= { extAlarmEntry 2 }
extAlarmStatus OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Dispaly 'Normal' or 'Alarm' string"
::= { extAlarmEntry 3 }
extAlarmTriggeredMode OBJECT-TYPE
SYNTAX INTEGER {
closeAlarm(1),
openAlarm(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The external alarm triggered mode."
::= { extAlarmEntry 4 }
--------------------
-- User Management
--------------------
userAuthMode OBJECT-TYPE
SYNTAX INTEGER {
local(1),
radius(2),
localThenRadius(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User authentication procsssing mode."
::= { user 1 }
userAuthServerIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the authentication server."
::= { user 2 }
userAuthServerPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port of the authentication server."
::= { user 3 }
userAuthServerSecret OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The secret between the authentication server and the NE for authentication process."
::= { user 4 }
-- userTable
userTable OBJECT-TYPE
SYNTAX SEQUENCE OF UserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains user information."
::= { user 5 }
userEntry OBJECT-TYPE
SYNTAX UserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of userTable."
INDEX { userName }
::= { userTable 1 }
UserEntry ::=
SEQUENCE {
userName DisplayString,
userPassword DisplayString,
userPriviledge INTEGER,
userRowStatus RowStatus
}
userName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user name."
::= { userEntry 1 }
userPassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The user password."
::= { userEntry 2 }
userPriviledge OBJECT-TYPE
SYNTAX INTEGER {
high(1),
middle(2),
low(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The user priviledge to decide what operation the user can and cannot do."
::= { userEntry 3 }
userRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status used to create or delete a user."
::= { userEntry 4 }
userAuthDefaultPriviledge OBJECT-TYPE
SYNTAX INTEGER {
high(1),
middle(2),
low(3),
deny(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The user default priviledge to be assigned when radius authentication succeds
but no user priviledge information(radius service-type) is provided."
::= { user 6 }
--------------------
-- Upstream Broadcast
--------------------
usBcastCtrlEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable upstream broadcast control."
::= { usbCastCtrl 1 }
usBcastCtrlRate OBJECT-TYPE
SYNTAX INTEGER
UNITS "Kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { usbCastCtrl 2 }
--------------------
-- Downstream QoS
--------------------
dsQosEnableMode OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
vlan(2),
dscp(3),
ippre(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable internal overriding mode to VLAN, DSCP or IP Precedence, or disable the overriding mode."
::= { dsQos 1 }
dsQosDefaultPri OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the internal default p.bit after overiding. All values not configured in the
overriding table are assigned to the default p.bit"
::= { dsQos 2 }
dsQoSOverridingTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsQoSOverridingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes downstream QoS overriding information."
::= { dsQos 3 }
dsQoSOverridingEntry OBJECT-TYPE
SYNTAX DsQoSOverridingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in dsQoSOverridingTable."
INDEX { dsQosPriority }
::= { dsQoSOverridingTable 1 }
DsQoSOverridingEntry ::=
SEQUENCE {
dsQosPriority INTEGER,
dsQosValueList DisplayString
}
dsQosPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Internal P.bit after overriding."
::= { dsQoSOverridingEntry 1 }
dsQosValueList OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN ID, DSCP, or IP Precedence based on the internal overriding mode configured.
VLAN ID 1 ~ 4094, DSCP 0 ~ 63, IP Precedence 0 ~ 7. value_list example: <1>, <1,3>, <1,5,6~10>."
::= { dsQoSOverridingEntry 2 }
--------------------
-- fwUpgrade
--------------------
fwUpgradeVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure the target firmware version that will be upgraded."
::= { fwUpgrade 1 }
fwUpgradeCheck OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable firmware upgrade version checking feature."
::= { fwUpgrade 2 }
fwUpgradeStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display current firmware upgrade status."
::= { fwUpgrade 3 }
--------------------
-- delayedReboot
--------------------
delayedRebootTimer OBJECT-TYPE
SYNTAX INTEGER
UNITS "sec"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"5~1800 secs, 0: reboot immediately."
::= { delayedReboot 1 }
delayedRebootRemainingTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "sec"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display the remaining time of scheduled reboot."
::= { delayedReboot 2 }
delayedRebootCancel OBJECT-TYPE
SYNTAX INTEGER {
cancel(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"cancel the scheduled reboot."
::= { delayedReboot 3 }
----------------------------------------
-- statistics
----------------------------------------
dhcpStats OBJECT IDENTIFIER ::= { statistics 11 }
paepvcStats OBJECT IDENTIFIER ::= { statistics 12 }
macStats OBJECT IDENTIFIER ::= { statistics 13 }
-- ipbpvcStats OBJECT IDENTIFIER ::= { statistics 14 }
n1macStats OBJECT IDENTIFIER ::= { statistics 15 }
enetStats OBJECT IDENTIFIER ::= { statistics 16 }
vdslStats OBJECT IDENTIFIER ::= { statistics 17 }
macffStats OBJECT IDENTIFIER ::= { statistics 19 }
adslStats OBJECT IDENTIFIER ::= { statistics 20 }
--------------------
-- IGMP
--------------------
igmpQueryCntTotal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of IGMP query messages received."
::= { statistics 1 }
igmpReportCntTotal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of IGMP report messages received."
::= { statistics 2 }
igmpLeaveCntTotal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of IGMP leave messages received."
::= { statistics 3 }
igmpNumOfActiveGroups OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of IGMP learned groups."
::= { statistics 4 }
-- igmpGroupTable
igmpGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes igmp group information."
::= { statistics 5 }
igmpGroupEntry OBJECT-TYPE
SYNTAX IgmpGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in igmpGroupTable."
INDEX { igmpGroupIp }
::= { igmpGroupTable 1 }
IgmpGroupEntry ::=
SEQUENCE {
igmpGroupIp IpAddress,
igmpGroupvid INTEGER,
igmpGroupnumberOfMembers INTEGER,
igmpGroupMemberPorts PortList
}
igmpGroupIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"igmp group IP"
::= { igmpGroupEntry 1 }
igmpGroupvid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"vlan id"
::= { igmpGroupEntry 2 }
igmpGroupnumberOfMembers OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number Of Members"
::= { igmpGroupEntry 3 }
igmpGroupMemberPorts OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Group Member Ports"
::= { igmpGroupEntry 4 }
-- igmpGroupPortTable
igmpGroupPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpGroupPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes igmp Group port information."
::= { statistics 6 }
igmpGroupPortEntry OBJECT-TYPE
SYNTAX IgmpGroupPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in igmpGroupPortTable."
INDEX { ifIndex , igmpGroupPortIp , igmpGroupPortvid}
::= { igmpGroupPortTable 1 }
IgmpGroupPortEntry ::=
SEQUENCE {
igmpGroupPortIp IpAddress,
igmpGroupPortvid INTEGER
}
igmpGroupPortIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Igmp Group IP"
::= { igmpGroupPortEntry 1 }
igmpGroupPortvid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Igmp Group vid"
::= { igmpGroupPortEntry 2 }
-- igmpGroupV2Table
igmpGroupV2Table OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpGroupV2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that displays IGMP learned group member information."
::= { statistics 7 }
igmpGroupV2Entry OBJECT-TYPE
SYNTAX IgmpGroupV2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of igmpGroupV2Table."
INDEX { igmpGroupV2Vid, igmpGroupV2Ip }
::= { igmpGroupV2Table 1 }
IgmpGroupV2Entry ::=
SEQUENCE {
igmpGroupV2Vid VlanIndex,
igmpGroupV2Ip IpAddress,
igmpGroupV2NumOfMembers INTEGER,
igmpGroupV2MemberPorts PortList
}
igmpGroupV2Vid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IGMP group VLAN ID."
::= { igmpGroupV2Entry 1 }
igmpGroupV2Ip OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The multicast IP address."
::= { igmpGroupV2Entry 2 }
igmpGroupV2NumOfMembers OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of member ports in the group."
::= { igmpGroupV2Entry 3 }
igmpGroupV2MemberPorts OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The member port list of the group."
::= { igmpGroupV2Entry 4 }
-- igmpGroupPortV2Table
igmpGroupPortV2Table OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpGroupPortV2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that displays IGMP joined groups in this port."
::= { statistics 8 }
igmpGroupPortV2Entry OBJECT-TYPE
SYNTAX IgmpGroupPortV2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of igmpGroupPortV2Table."
INDEX { ifIndex, igmpGroupPortV2Vid, igmpGroupPortV2Ip, igmpGroupPortV2SourceIp }
::= { igmpGroupPortV2Table 1 }
IgmpGroupPortV2Entry ::=
SEQUENCE {
igmpGroupPortV2Vid VlanIndex,
igmpGroupPortV2Ip IpAddress,
igmpGroupPortV2SourceIp IpAddress
}
igmpGroupPortV2Vid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IGMP group VLAN ID."
::= { igmpGroupPortV2Entry 1 }
igmpGroupPortV2Ip OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The multicast IP address."
::= { igmpGroupPortV2Entry 2 }
igmpGroupPortV2SourceIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The source IP address that joins the IGMP group."
::= { igmpGroupPortV2Entry 3 }
-- igmpPortCtrlPduTable
igmpPortCtrlPduTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpPortCtrlPduEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that displays IGMP related counter values in this port."
::= { statistics 9 }
igmpPortCtrlPduEntry OBJECT-TYPE
SYNTAX IgmpPortCtrlPduEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of igmpPortCtrlPduTable."
INDEX { ifIndex }
::= { igmpPortCtrlPduTable 1 }
IgmpPortCtrlPduEntry ::=
SEQUENCE {
igmpPortCtrlPduQueryCnt Counter32,
igmpPortCtrlPduReportCnt Counter32,
igmpPortCtrlPduLeaveCnt Counter32,
igmpPortNumOfActiveGroups INTEGER,
igmpPortCtrlAuditLeaveCnt Counter32
}
igmpPortCtrlPduQueryCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of IGMP query messages received in this port."
::= { igmpPortCtrlPduEntry 1 }
igmpPortCtrlPduReportCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of IGMP report messages received in this port."
::= { igmpPortCtrlPduEntry 2 }
igmpPortCtrlPduLeaveCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of IGMP leave messages received in this port."
::= { igmpPortCtrlPduEntry 3 }
igmpPortNumOfActiveGroups OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of active IGMP groups in this port."
::= { igmpPortCtrlPduEntry 4 }
igmpPortCtrlAuditLeaveCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of groups left by audit query."
::= { igmpPortCtrlPduEntry 5 }
--------------------
-- vdslStats
--------------------
-- vdslLineStatsTable
vdslLineStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF VdslLineStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table displays VDSL line statistics."
::= { vdslStats 2 }
vdslLineStatsEntry OBJECT-TYPE
SYNTAX VdslLineStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of vdslLineStatsTable."
INDEX { ifIndex }
::= { vdslLineStatsTable 1 }
VdslLineStatsEntry ::=
SEQUENCE {
vdslLineStatsVtucBits1 OCTET STRING,
vdslLineStatsVtucBits2 OCTET STRING,
vdslLineStatsVtucBits3 OCTET STRING,
vdslLineStatsVtucBits4 OCTET STRING,
vdslLineStatsVturBits1 OCTET STRING,
vdslLineStatsVturBits2 OCTET STRING,
vdslLineStatsVturBits3 OCTET STRING,
vdslLineStatsVturBits4 OCTET STRING,
vdslLineStatsVtucGain1 OCTET STRING,
vdslLineStatsVtucGain2 OCTET STRING,
vdslLineStatsVtucGain3 OCTET STRING,
vdslLineStatsVtucGain4 OCTET STRING,
vdslLineStatsVtucGain5 OCTET STRING,
vdslLineStatsVtucGain6 OCTET STRING,
vdslLineStatsVtucGain7 OCTET STRING,
vdslLineStatsVtucGain8 OCTET STRING,
vdslLineStatsVturGain1 OCTET STRING,
vdslLineStatsVturGain2 OCTET STRING,
vdslLineStatsVturGain3 OCTET STRING,
vdslLineStatsVturGain4 OCTET STRING,
vdslLineStatsVturGain5 OCTET STRING,
vdslLineStatsVturGain6 OCTET STRING,
vdslLineStatsVturGain7 OCTET STRING,
vdslLineStatsVturGain8 OCTET STRING,
vdslLineStatsVtucHlog OCTET STRING,
vdslLineStatsVturHlog OCTET STRING,
vdslLineStatsVtucQln OCTET STRING,
vdslLineStatsVturQln OCTET STRING,
vdslLineStatsVtucSnr OCTET STRING,
vdslLineStatsVturSnr OCTET STRING,
vdslLineStatsVtucTssi OCTET STRING,
vdslLineStatsVturTssi OCTET STRING,
vdslLineStatsProtocol INTEGER
}
vdslLineStatsVtucBits1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Bits for the VTU-C 1024 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 15."
::= { vdslLineStatsEntry 1 }
vdslLineStatsVtucBits2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Bits for the VTU-C 1024 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 15."
::= { vdslLineStatsEntry 2 }
vdslLineStatsVtucBits3 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Bits for the VTU-C 1024 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 15."
::= { vdslLineStatsEntry 3 }
vdslLineStatsVtucBits4 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Bits for the VTU-C 1024 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 15."
::= { vdslLineStatsEntry 4 }
vdslLineStatsVturBits1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Bits for the VTU-R 1024 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 15."
::= { vdslLineStatsEntry 5 }
vdslLineStatsVturBits2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Bits for the VTU-R 1024 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 15."
::= { vdslLineStatsEntry 6 }
vdslLineStatsVturBits3 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Bits for the VTU-R 1024 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 15."
::= { vdslLineStatsEntry 7 }
vdslLineStatsVturBits4 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Bits for the VTU-R 1024 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 15."
::= { vdslLineStatsEntry 8 }
vdslLineStatsVtucGain1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 9 }
vdslLineStatsVtucGain2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 10 }
vdslLineStatsVtucGain3 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 11 }
vdslLineStatsVtucGain4 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 12 }
vdslLineStatsVtucGain5 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 13 }
vdslLineStatsVtucGain6 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 14 }
vdslLineStatsVtucGain7 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 15 }
vdslLineStatsVtucGain8 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 16 }
vdslLineStatsVturGain1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 17 }
vdslLineStatsVturGain2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 18 }
vdslLineStatsVturGain3 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 19 }
vdslLineStatsVturGain4 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 20 }
vdslLineStatsVturGain5 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 21 }
vdslLineStatsVturGain6 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 22 }
vdslLineStatsVturGain7 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 23 }
vdslLineStatsVturGain8 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 24 }
vdslLineStatsVtucHlog OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Hlog for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The real Hlog(f) value is represented as (6-m(i)/10), with m(i) in the range 0 to 1022.
A special value m=1023 indicates that no measurement could be done for the
sub-carrier group becauseit is out of the passband or that the attenuation
is out of range to be represented. Each value in this array is 16 bits wide."
::= { vdslLineStatsEntry 25 }
vdslLineStatsVturHlog OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Hlog for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The real Hlog(f) value is represented as (6-m(i)/10), with m(i) in the range 0 to 1022.
A special value m=1023 indicates that no measurement could be done for the
sub-carrier group because it is out of the passband or that the attenuation
is out ofrange to be represented. Each value in this array is 16 bits wide."
::= { vdslLineStatsEntry 26 }
vdslLineStatsVtucQln OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Qln for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The QLN(f) is represented as ( -23-n(i)/2), with n(i) in the range 0 to 254.
A special value n(i)=255 indicates that no measurement could be done for the
sub-carrier group. Each value in this array is 8 bits wide."
::= { vdslLineStatsEntry 27 }
vdslLineStatsVturQln OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Qln for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The QLN(f) is represented as ( -23-n(i)/2), with n(i) in the range 0 to 254.
A special value n(i)=255 indicates that no measurement could be done for the
sub-carrier group. Each value in this array is 8 bits wide."
::= { vdslLineStatsEntry 28 }
vdslLineStatsVtucSnr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Snr for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
Octet i is set to a value in the range 0 to 254 (-32 + vdslLineStatsVtucSnr (i)/2) in dB
(i.e., -32 to 95dB). Each value in this array is 8 bits wide."
::= { vdslLineStatsEntry 29 }
vdslLineStatsVturSnr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Snr for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
Octet i is set to a value in the range 0 to 254 (-32 + vdslLineStatsVturSnr (i)/2) in dB
(i.e., -32 to 95dB). Each value in this array is 8 bits wide."
::= { vdslLineStatsEntry 30 }
vdslLineStatsVtucTssi OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Tssi for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
Each value in this array is 16 bits wide.
The tssi value is represented as a multiple of 1/32768 on linear scale."
::= { vdslLineStatsEntry 31 }
vdslLineStatsVturTssi OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Tssi for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
Each value in this array is 16 bits wide.
The tssi value is represented as a multiple of 1/32768 on linear scale."
::= { vdslLineStatsEntry 32 }
vdslLineStatsProtocol OBJECT-TYPE
SYNTAX INTEGER {
none(1),
vdsl8a(2),
vdsl8b(3),
vdsl8c(4),
vdsl8d(5),
vdsl12a(6),
vdsl12b(7),
vdsl17a(8),
gdmt(9),
glite(10),
adsl2(11),
adsl2plus(12),
t1413(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual line protocol."
::= { vdslLineStatsEntry 33 }
--------------------
-- DHCP
--------------------
-- dhcpSnoopIpTable
dhcpSnoopIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpSnoopIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table shows the IP addresses and netmasks offered by the DHCP server."
::= { dhcpStats 1 }
dhcpSnoopIpEntry OBJECT-TYPE
SYNTAX DhcpSnoopIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dhcpSnoopIpTable."
INDEX { ifIndex, dhcpSnoopIp }
::= { dhcpSnoopIpTable 1 }
DhcpSnoopIpEntry ::=
SEQUENCE {
dhcpSnoopIp IpAddress,
dhcpSnoopMac PhysAddress,
dhcpSnoopVid VlanIndex,
dhcpSnoopMask INTEGER,
dhcpSnoopGateway IpAddress,
dhcpSnoopRouteMap OCTET STRING
}
dhcpSnoopIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The snooped IP address."
::= { dhcpSnoopIpEntry 1 }
dhcpSnoopMac OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The snooped MAC address."
::= { dhcpSnoopIpEntry 2 }
dhcpSnoopVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The snooped VLAN ID."
::= { dhcpSnoopIpEntry 3 }
dhcpSnoopMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The snooped IP mask"
::= { dhcpSnoopIpEntry 4 }
dhcpSnoopGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The snooped Gateway."
::= { dhcpSnoopIpEntry 5 }
dhcpSnoopRouteMap OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The refrence bit map of the dhcp route"
::= { dhcpSnoopIpEntry 6 }
-- dhcpSnoopCounterTable
dhcpSnoopCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpSnoopCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table shows the DHCP statistics."
::= { dhcpStats 2 }
dhcpSnoopCounterEntry OBJECT-TYPE
SYNTAX DhcpSnoopCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dhcpSnoopCounterTable."
INDEX { ifIndex }
::= { dhcpSnoopCounterTable 1 }
DhcpSnoopCounterEntry ::=
SEQUENCE {
dhcpDiscovery Counter64,
dhcpOffer Counter64,
dhcpRequest Counter64,
dhcpAck Counter64,
dhcpAckBySnoopFull Counter64
}
dhcpDiscovery OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of received DHCP server discovery packets."
::= { dhcpSnoopCounterEntry 1 }
dhcpOffer OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of received DHCP server offer packets."
::= { dhcpSnoopCounterEntry 2 }
dhcpRequest OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of received DHCP IP request packets."
::= { dhcpSnoopCounterEntry 3 }
dhcpAck OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of received DHCP IP acknowledge packets."
::= { dhcpSnoopCounterEntry 4 }
dhcpAckBySnoopFull OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of received DHCP IP acknowledge packets that replace the oldest snooping
entry in snooping table due to table full."
::= { dhcpSnoopCounterEntry 5 }
dhcpRouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains dhcp route information."
::= { dhcpStats 3 }
dhcpRouteEntry OBJECT-TYPE
SYNTAX DhcpRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dhcpRouteTable."
INDEX { dhcpRouteIndex }
::= { dhcpRouteTable 1 }
DhcpRouteEntry ::=
SEQUENCE {
dhcpRouteIndex INTEGER,
dhcpRouteVid VlanIndex,
dhcpRouteIP IpAddress,
dhcpRouteMask INTEGER,
dhcpRouteGwIP IpAddress
}
dhcpRouteIndex OBJECT-TYPE
SYNTAX INTEGER (1..24)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { dhcpRouteEntry 1 }
dhcpRouteVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VLAN-ID refering to this dhcp route."
::= { dhcpRouteEntry 2 }
dhcpRouteIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP of this dhcp route"
::= { dhcpRouteEntry 3 }
dhcpRouteMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The subnet mask of source IP mask."
::= { dhcpRouteEntry 4 }
dhcpRouteGwIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The gateway IP address."
::= { dhcpRouteEntry 5 }
--------------------
-- PAE PVC
--------------------
-- paepvcSessionTable
paepvcSessionTable OBJECT-TYPE
SYNTAX SEQUENCE OF PaepvcSessionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table shows the paepvc session statistics."
::= { paepvcStats 1 }
paepvcSessionEntry OBJECT-TYPE
SYNTAX PaepvcSessionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of paepvcSessionTable."
INDEX { ifIndex , paepvcSessionVpi, paepvcSessionVci }
::= { paepvcSessionTable 1 }
PaepvcSessionEntry ::=
SEQUENCE {
paepvcSessionVpi INTEGER,
paepvcSessionVci INTEGER,
paepvcSessionState INTEGER,
paepvcSessionId INTEGER,
paepvcSessionUptime Unsigned32,
paepvcSessionacname DisplayString,
paepvcSessionsrvcname DisplayString
}
paepvcSessionVpi OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PAEPVC VPI."
::= { paepvcSessionEntry 1 }
paepvcSessionVci OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PAEPVC VCI."
::= { paepvcSessionEntry 2 }
paepvcSessionState OBJECT-TYPE
SYNTAX INTEGER {
down(1),
pppoe(2),
ppp(3),
up(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PAEPVC status."
::= { paepvcSessionEntry 3 }
paepvcSessionId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PAEPVC session ID."
::= { paepvcSessionEntry 4 }
paepvcSessionUptime OBJECT-TYPE
SYNTAX Unsigned32
UNITS "second"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PAEPVC session uptime."
::= { paepvcSessionEntry 5 }
paepvcSessionacname OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Access concentrator name."
::= { paepvcSessionEntry 6 }
paepvcSessionsrvcname OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Service name."
::= { paepvcSessionEntry 7 }
-- paepvcCountTable
paepvcCountTable OBJECT-TYPE
SYNTAX SEQUENCE OF PaepvcCountEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table shows the paepvc counters."
::= { paepvcStats 2 }
paepvcCountEntry OBJECT-TYPE
SYNTAX PaepvcCountEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of paepvcCountTable."
INDEX { ifIndex , paepvcCountVpi, paepvcCountVci }
::= { paepvcCountTable 1 }
PaepvcCountEntry ::=
SEQUENCE {
paepvcCountVpi INTEGER,
paepvcCountVci INTEGER,
paepvcCountPppLcpCfgReqRx Unsigned32,
paepvcCountPppLcpEchoReqRx Unsigned32,
paepvcCountPppLcpEchoReplyRx Unsigned32,
paepvcCountPadiTx Unsigned32,
paepvcCountPadoRx Unsigned32,
paepvcCountPadrTx Unsigned32,
paepvcCountPadsRx Unsigned32,
paepvcCountPadtTx Unsigned32,
paepvcCountPadtRx Unsigned32,
paepvcCountSrvcnameErrRx Unsigned32,
paepvcCountAcSystemErrRx Unsigned32,
paepvcCountGenericErrTx Unsigned32,
paepvcCountGenericErrRx Unsigned32
}
paepvcCountVpi OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PAEPVC VPI."
::= { paepvcCountEntry 1 }
paepvcCountVci OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PAEPVC VCI."
::= { paepvcCountEntry 2 }
paepvcCountPppLcpCfgReqRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ppp lcp config-request received."
::= { paepvcCountEntry 3 }
paepvcCountPppLcpEchoReqRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ppp lcp echo-request received."
::= { paepvcCountEntry 4 }
paepvcCountPppLcpEchoReplyRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ppp lcp echo-reply received."
::= { paepvcCountEntry 5 }
paepvcCountPadiTx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe padi transfered"
::= { paepvcCountEntry 6 }
paepvcCountPadoRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe pado received"
::= { paepvcCountEntry 7 }
paepvcCountPadrTx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe padr transfered"
::= { paepvcCountEntry 8 }
paepvcCountPadsRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe pads received"
::= { paepvcCountEntry 9 }
paepvcCountPadtTx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe padt transfered"
::= { paepvcCountEntry 10 }
paepvcCountPadtRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe padt received"
::= { paepvcCountEntry 11 }
paepvcCountSrvcnameErrRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe service name error received"
::= { paepvcCountEntry 12 }
paepvcCountAcSystemErrRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe access concentrator name error received"
::= { paepvcCountEntry 13 }
paepvcCountGenericErrTx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe generic error transfered"
::= { paepvcCountEntry 14 }
paepvcCountGenericErrRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe generic error received"
::= { paepvcCountEntry 15 }
--------------------
-- MAC
--------------------
macDisplayTarget OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This managed object is a filter used for identify the target from which
the MAC addresses are learned in macTable. The target could be:
99: all ports in the system
98: all subscriber ports
97: all Ethernet ports
IfIndex is used for identifying subscriber ports and Ethernet Ports(e.g. 1 ~ 50)."
::= { macStats 1 }
-- macTable
macTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains information about unicast
entries for which the bridge has forwarding and/or
filtering information. This information is used
by the transparent bridging function in
determining how to propagate a received frame."
::= { macStats 2 }
macEntry OBJECT-TYPE
SYNTAX MacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of macTable."
INDEX { dot1qVlanIndex, macAddress }
::= { macTable 1 }
MacEntry ::=
SEQUENCE {
macAddress MacAddress,
macPort INTEGER,
macStatus INTEGER,
macVid VlanIndex
}
macAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unicast MAC address for which the bridge has
forwarding and/or filtering information."
::= { macEntry 1 }
macPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port from which the mac address has been learned."
::= { macEntry 2 }
macStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
invalid(2),
learned(3),
self(4),
mgmt(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of this entry."
::= { macEntry 3 }
macVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vlan id of this entry."
::= { macEntry 4 }
--------------------
-- ipbpvc
--------------------
-- arpproxyTable
-- arpproxyTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF ArpproxyEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "Display ARP table. This table is supported by R3.00 and later versions."
-- ::= { ipbpvcStats 1 }
--
-- arpproxyEntry OBJECT-TYPE
-- SYNTAX ArpproxyEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry of arpproxyTable."
-- INDEX { ipbpvcDomainName, arpproxyIp }
-- ::= { arpproxyTable 1 }
--
-- ArpproxyEntry ::=
-- SEQUENCE {
-- arpproxyIp IpAddress,
-- arpproxyMac MacAddress,
-- arpproxyIfIndex INTEGER,
-- arpproxyVpi INTEGER,
-- arpproxyVci INTEGER,
-- arpproxyInterfaceIp IpAddress,
-- arpproxyInterfaceMask INTEGER,
-- arpproxyInterfaceVid VlanIndex,
-- arpproxyDhcpIp INTEGER,
-- arpproxyType INTEGER
-- }
--
-- arpproxyIp OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { arpproxyEntry 1 }
--
-- arpproxyMac OBJECT-TYPE
-- SYNTAX MacAddress
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { arpproxyEntry 2 }
--
-- arpproxyIfIndex OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { arpproxyEntry 3 }
--
-- arpproxyVpi OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { arpproxyEntry 4 }
--
-- arpproxyVci OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { arpproxyEntry 5 }
--
-- arpproxyInterfaceIp OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { arpproxyEntry 6 }
--
-- arpproxyInterfaceMask OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { arpproxyEntry 7 }
--
-- arpproxyInterfaceVid OBJECT-TYPE
-- SYNTAX VlanIndex
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { arpproxyEntry 8 }
--
-- arpproxyDhcpIp OBJECT-TYPE
-- SYNTAX INTEGER {
-- true(1),
-- false(2)
-- }
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { arpproxyEntry 9 }
--
-- arpproxyType OBJECT-TYPE
-- SYNTAX INTEGER {
-- upstream(1),
-- downstream(2)
-- }
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { arpproxyEntry 10 }
--
-- ipbpvcIfDynamicTable
--
-- ipbpvcIfDynamicTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF IpbpvcIfDynamicEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "Display runtime interfaces. This table is supported by R3.00 and later versions."
-- ::= { ipbpvcStats 2 }
--
-- ipbpvcIfDynamicEntry OBJECT-TYPE
-- SYNTAX IpbpvcIfDynamicEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry of ipbpvcIfDynamicTable."
-- INDEX { ipbpvcDomainName, ipbpvcIfDynamicIp, ipbpvcIfDynamicMask, ipbpvcDomainVlanId }
-- ::= { ipbpvcIfDynamicTable 1 }
--
-- IpbpvcIfDynamicEntry ::=
-- SEQUENCE {
-- ipbpvcIfDynamicIp IpAddress,
-- ipbpvcIfDynamicMask INTEGER,
-- ipbpvcIfDynamicIfIndex INTEGER,
-- ipbpvcIfDynamicVpi INTEGER,
-- ipbpvcIfDynamicVci INTEGER
-- }
--
-- ipbpvcIfDynamicIp OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { ipbpvcIfDynamicEntry 1 }
--
-- ipbpvcIfDynamicMask OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { ipbpvcIfDynamicEntry 2 }
--
-- ipbpvcIfDynamicIfIndex OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { ipbpvcIfDynamicEntry 3 }
--
-- ipbpvcIfDynamicVpi OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { ipbpvcIfDynamicEntry 4 }
--
-- ipbpvcIfDynamicVci OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { ipbpvcIfDynamicEntry 5 }
--
-- ipbpvcRouteDynamicTable
--
-- ipbpvcRouteDynamicTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF IpbpvcRouteDynamicEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "Display runtime routing table. This table is supported by R3.00 and later versions."
-- ::= { ipbpvcStats 3 }
--
-- ipbpvcRouteDynamicEntry OBJECT-TYPE
-- SYNTAX IpbpvcRouteDynamicEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry of ipbpvcRouteDynamicTable."
-- INDEX { ipbpvcDomainName, ipbpvcRouteDynamicType, ipbpvcRouteDynamicIp, ipbpvcRouteDynamicMask }
-- ::= { ipbpvcRouteDynamicTable 1 }
--
-- IpbpvcRouteDynamicEntry ::=
-- SEQUENCE {
-- ipbpvcRouteDynamicType INTEGER,
-- ipbpvcRouteDynamicIp IpAddress,
-- ipbpvcRouteDynamicMask INTEGER,
-- ipbpvcRouteDynamicNextHop IpAddress,
-- ipbpvcRouteDynamicMetric INTEGER,
-- ipbpvcRouteDynamicPriority INTEGER
-- }
--
-- ipbpvcRouteDynamicType OBJECT-TYPE
-- SYNTAX INTEGER {
-- upstream(1),
-- downstream(2)
-- }
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { ipbpvcRouteDynamicEntry 1 }
--
-- ipbpvcRouteDynamicIp OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { ipbpvcRouteDynamicEntry 2 }
--
-- ipbpvcRouteDynamicMask OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { ipbpvcRouteDynamicEntry 3 }
--
-- ipbpvcRouteDynamicNextHop OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { ipbpvcRouteDynamicEntry 4 }
--
-- ipbpvcRouteDynamicMetric OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { ipbpvcRouteDynamicEntry 5 }
--
-- ipbpvcRouteDynamicPriority OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { ipbpvcRouteDynamicEntry 6 }
------------------------------
-- n1macStats
------------------------------
n1macTable OBJECT-TYPE
SYNTAX SEQUENCE OF N1macEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains information about N to 1
MAC translation, including connection type,
session id/IP and MAC address."
::= { n1macStats 1 }
n1macEntry OBJECT-TYPE
SYNTAX N1macEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of n1macTable."
INDEX { ifIndex, n1macProtoVal}
::= { n1macTable 1 }
N1macEntry ::=
SEQUENCE {
n1macProtoVal Unsigned32,
n1macProtoType INTEGER,
n1macMacAddr MacAddress
}
n1macProtoVal OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The protocol value of specified connection. If the connection
is pppoe/pppoaoe, the value stands for session id; if the
connection is ipoe/ipoaoe, the value means IP address."
::= { n1macEntry 1 }
n1macProtoType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ipoe(2),
ipoaoe(3),
pppoe(4),
pppoaoe(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Protocol type of the connection which the MAC is translated."
::= { n1macEntry 2 }
n1macMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The translated MAC address."
::= { n1macEntry 3 }
------------------------------
-- enetStats
------------------------------
enetPrimaryPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" IfIndex is used for identifying the Primary Ethernet Port when dot3ad is disabled."
::= { enetStats 1 }
enetSfpInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF EnetSfpInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes sfp info of enet port."
::= { enetStats 2 }
enetSfpInfoEntry OBJECT-TYPE
SYNTAX EnetSfpInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in enetSfpInfoTable."
INDEX {ifIndex}
::= { enetSfpInfoTable 1 }
EnetSfpInfoEntry ::=
SEQUENCE {
enetSfpInfoTxpower INTEGER,
enetSfpInfoRxpower INTEGER,
enetSfpInfoTemperature INTEGER,
enetSfpInfoTxBias INTEGER,
enetSfpInfoVoltage INTEGER
}
enetSfpInfoTxpower OBJECT-TYPE
SYNTAX INTEGER (1..65535)
UNITS "10^-4 mW"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured Tx Output Power."
::= { enetSfpInfoEntry 1 }
enetSfpInfoRxpower OBJECT-TYPE
SYNTAX INTEGER (1..65535)
UNITS "10^-4 C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured Rx Output Power."
::= { enetSfpInfoEntry 2 }
enetSfpInfoTemperature OBJECT-TYPE
SYNTAX INTEGER (-1280000..1280000)
UNITS "10^-4 C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured temperature."
::= { enetSfpInfoEntry 3 }
enetSfpInfoTxBias OBJECT-TYPE
SYNTAX INTEGER (0..131000)
UNITS "10^-3 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured tx bias."
::= { enetSfpInfoEntry 4 }
enetSfpInfoVoltage OBJECT-TYPE
SYNTAX INTEGER (0..65000)
UNITS "0.1mV"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured voltage."
::= { enetSfpInfoEntry 5 }
----------------------------------------
-- macFfStats
----------------------------------------
macFfStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFfStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains MAC Force Forwarding static configuration and dynamic information."
::= { macffStats 1 }
macFfStatsEntry OBJECT-TYPE
SYNTAX MacFfStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of macFfStatsTable."
INDEX { macFfStatsIndex }
::= { macFfStatsTable 1 }
MacFfStatsEntry ::=
SEQUENCE {
macFfStatsIndex INTEGER,
macFfStatsVid VlanIndex,
macFfStatsArIP IpAddress,
macFfStatsSrcIP IpAddress,
macFfStatsSrcMask INTEGER
}
macFfStatsIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the MACFF."
::= { macFfStatsEntry 1 }
macFfStatsVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VLAN-ID refering to this AR/AS."
::= { macFfStatsEntry 2 }
macFfStatsArIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP of this AR/AS"
::= { macFfStatsEntry 3 }
macFfStatsSrcIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The source IP address of the MACFF."
::= { macFfStatsEntry 4 }
macFfStatsSrcMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The subnet mask of source IP mask."
::= { macFfStatsEntry 5 }
macFfArpTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFfArpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains MAC Force Forwarding ARP information."
::= { macffStats 2 }
macFfArpEntry OBJECT-TYPE
SYNTAX MacFfArpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of macFfArpTable."
INDEX { macFfArpVid, macFfArpIP}
::= { macFfArpTable 1 }
MacFfArpEntry ::=
SEQUENCE {
macFfArpVid VlanIndex,
macFfArpIP IpAddress,
macFfArpPort INTEGER,
macFfArpMac PhysAddress
}
macFfArpVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VLAN-ID refering to this AR/AS."
::= { macFfArpEntry 1 }
macFfArpIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP of this AR/AS."
::= { macFfArpEntry 2 }
macFfArpPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port of this AR/AS."
::= { macFfArpEntry 3 }
macFfArpMac OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the AR or AS."
::= { macFfArpEntry 4 }
macFfArpCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFfArpCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains MAC Force Forwarding ARP counter information."
::= { macffStats 3 }
macFfArpCounterEntry OBJECT-TYPE
SYNTAX MacFfArpCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of macFfArpCounterTable."
INDEX { ifIndex }
::= { macFfArpCounterTable 1 }
MacFfArpCounterEntry ::=
SEQUENCE {
macFfArpCounterRequestTX Counter32,
macFfArpCounterRequestRX Counter32,
macFfArpCounterRequestRXDrop Counter32,
macFfArpCounterReplyTX Counter32,
macFfArpCounterReplyRX Counter32,
macFfArpCounterReplyRXDrop Counter32
}
macFfArpCounterRequestTX OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ARP Request TX counter."
::= { macFfArpCounterEntry 1 }
macFfArpCounterRequestRX OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ARP Request RX counter."
::= { macFfArpCounterEntry 2 }
macFfArpCounterRequestRXDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ARP Request RX drop counter."
::= { macFfArpCounterEntry 3 }
macFfArpCounterReplyTX OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ARP Reply TX counter."
::= { macFfArpCounterEntry 4 }
macFfArpCounterReplyRX OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ARP Reply RX counter."
::= { macFfArpCounterEntry 5 }
macFfArpCounterReplyRXDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ARP Reply RX drop counter."
::= { macFfArpCounterEntry 6 }
------------------------------
-- adslStats
------------------------------
adslPortUtilTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdslPortUtilEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes adsl port utilization."
::= { adslStats 1 }
adslPortUtilEntry OBJECT-TYPE
SYNTAX AdslPortUtilEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in adslPortUtilEntry."
INDEX {ifIndex}
::= { adslPortUtilTable 1 }
AdslPortUtilEntry ::=
SEQUENCE {
adslPortUtilTx INTEGER,
adslPortUtilRx INTEGER,
adslStatsXturInp DisplayString,
adslStatsXtucInp DisplayString
}
adslPortUtilTx OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measure adsl port's tx utilization."
::= { adslPortUtilEntry 1 }
adslPortUtilRx OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measure adsl port's rx utilization."
::= { adslPortUtilEntry 2 }
adslStatsXturInp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"XTUR minimum INP value."
::= { adslPortUtilEntry 3 }
adslStatsXtucInp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"XTUC minimum INP valu."
::= { adslPortUtilEntry 4 }
----------------------------------------
-- clear
----------------------------------------
counterClearTarget OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This managed object is used for identify the target on which
the counter would be cleared. The target is encoded as:
Byte 1: reserved
Byte 2~3: reserved
Byte 4: reserved
Byte 5~11:each octet specifies a set of eight ports, with the first
octet specifying ports 1 through 8, etc."
::= { clear 1 }
counterClearOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The corresponding bit is set to 1 to start the operation.
The various bit positions are:
BIT 1: clear interface counters
BIT 2: clear pvc packet counters
BIT 3: not support
BIT 4: not support
BIT 5: clear DHCP counters
BIT 6: clear IGMP counters
BIT 7: clear IGMP port counters"
::= { clear 2 }
counterClearVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VPI of the pvc whose counters would be cleared."
::= { clear 3 }
counterClearVci OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VCI of the pvc whose counters would be cleared."
::= { clear 4 }
END