OCCAM-MLT-MIB DEFINITIONS ::= BEGIN
IMPORTS
occamGenericMonitorModules
FROM OCCAM-REG-MODULE
TEXTUAL-CONVENTION
FROM SNMPv2-TC
MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY,
Integer32, NOTIFICATION-TYPE
FROM SNMPv2-SMI;
occamMltMib MODULE-IDENTITY
LAST-UPDATED "200104271051Z"
ORGANIZATION "Occam Networks"
CONTACT-INFO "email support@occamnetworks.com"
DESCRIPTION
"This mib module describes objects used
to perform Metallic Line Testing on customer
access lines and to provide results."
REVISION "200104271051Z"
DESCRIPTION "Reformatted certain text"
REVISION "200704170000Z"
DESCRIPTION "replace kOhm with Ohm in DC resistance
UNITS"
REVISION "200702220000Z"
DESCRIPTION "remove DISPLAY-HINT"
REVISION "200609261000Z"
DESCRIPTION "Removed Gr909 from fuse test result names"
REVISION "200602220135Z"
DESCRIPTION "Initial version."
::= { occamGenericMonitorModules 3 }
-- TEXTUAL-CONVENTIONS --
MltTestType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A selection value for requesting or forcing
a test. A requested test will only run if the
port is not in use. A forced test will
immediately shut the port and run the test."
SYNTAX INTEGER { request ( 1 ) ,
force ( 2 ) }
MltTestStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An indication of test status:
none = no test has been requested.
mltbusy = another port is currently being tested.
complete = the last requested test has completed.
portInUse = the last requested port is in use,
the test was not run. Rerunning the test as
'forced' will shut the port and run the test.
inProgress = the last requested test is still
running. mltError = the mlt program reported an
error and aborted the test.Check the mltErrorText
object.
mltNotResponding = the mlt program didn't return
a result."
SYNTAX INTEGER {
none ( 1 ) ,
mltBusy ( 2 ),
complete ( 3 ) ,
portInUse ( 4 ) ,
inProgress ( 5 ),
mltError ( 6 ),
mltNotResponding ( 7 ) }
MltTestIdentifier ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An mlt test selection value."
SYNTAX INTEGER {
statusSuite ( 1 ) ,
mltSuite ( 2 ) ,
activeModeVoltages ( 3 ) ,
highImpedanceModeVoltages ( 4 ) ,
dcResistance ( 5 ) ,
capacitance ( 6 ) ,
loopDetect ( 7 ) ,
loopLength ( 8 ) }
MltTestHookState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An mlt test hook state value."
SYNTAX INTEGER {
onhook ( 1 ) ,
offhook ( 2 ),
notAvailable ( 3 ) }
MltTestPassFail ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An mlt test pass/fail value."
SYNTAX INTEGER {
pass ( 1 ) ,
fail ( 2 ),
notAvailable ( 3 ) }
MltTestRingerResult ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An mlt ringer test result value."
SYNTAX INTEGER {
pass ( 1 ) ,
fail ( 2 ),
notAvailable ( 3 ),
low ( 4 ) }
MltTestYesNo ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An mlt test pass/fail value."
SYNTAX INTEGER {
yes ( 1 ) ,
no ( 2 ),
notAvailable ( 3 ) }
-- The Metallic Loop Test Configuration group
mltTestConfig OBJECT IDENTIFIER
::= { occamMltMib 1 }
-- The Metallic Loop Test Status group
mltTestStatus OBJECT IDENTIFIER
::= { occamMltMib 2 }
-- The Metallic Loop Test Results group
mltTestResults OBJECT IDENTIFIER
::= { occamMltMib 3 }
-- The Metallic Loop Test Notifications group
mltTestNotifications OBJECT IDENTIFIER
::= { occamMltMib 4 }
-- Objects of the MLT Configuration group
mltTestIdentifier OBJECT-TYPE
SYNTAX MltTestIdentifier
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the mlt test to be run.
Setting this value starts a test.
This is a required parameter.
Approximate expected test durations are as
follows:
statusSuite 1 second
mltSuite 1 minute
activeModeVoltages 3 seconds
highImpedanceModeVoltages 9 seconds
dcResistance 18 seconds
capacitance 18 seconds
loopDetect 9 seconds
loopLength 9 seconds."
::= { mltTestConfig 1 }
mltTestType OBJECT-TYPE
SYNTAX MltTestType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects if a test is requested (only run if port
is not in use) or forced.
This is an optional parameter. If not specified,
the request option is used."
::= { mltTestConfig 2 }
mltTestPort OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 48 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects voice channel on which test will be run.
This is a required parameter."
::= { mltTestConfig 3 }
mltDcResistanceRange OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 3 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects DC Resistance range value.
This is an optional paramater. Default is 0
(auto mode)."
::= { mltTestConfig 4 }
mltLoopLengthMultiplier OBJECT-TYPE
SYNTAX Integer32 ( 10 .. 200 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects loop length multiplier in nf. This is an
optional parameter. If not specified an internal
default value of 83nF/mile is used."
::= { mltTestConfig 5 }
mltLoopDetectThreshold OBJECT-TYPE
SYNTAX Integer32 ( 5 .. 200 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the detection threshold in nF.
This is an optional parameter. If not supplied,
a loop detection threshold of 10nF is used."
::= { mltTestConfig 6 }
-- Objects of the MLT Test Status group
mltLastTestStatus OBJECT-TYPE
SYNTAX MltTestStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the status of the last run mlt test.
Given that the various mlt tests take several
seconds to 1 1/2 minutes to run, it is suggested
that status polls be spaced 10-20 seconds apart.
Additionally, a monitoring application could
wait for the testComplete notification."
::= { mltTestStatus 1 }
mltErrorText OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the textual error in the case of an
aborted test."
::= { mltTestStatus 2 }
-- Objects of the MLT Test Results group
-- mlt status results table
mltStatusResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MltStatusResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides result of the status test
suite."
::= { mltTestResults 1 }
mltStatusResultsEntry OBJECT-TYPE
SYNTAX MltStatusResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry holding information about results
of status suite tests.
Note that a numerical result value of -999 means
that there was an error of some sort and the
value could not be measured."
INDEX { mltTestPort }
::= { mltStatusResultsTable 1 }
MltStatusResultsEntry ::= SEQUENCE {
mltStatusAlarm OCTET STRING,
mltStatusHookState MltTestHookState,
mltStatusTransversalCurrent Integer32,
mltStatusLongitudinalCurrent Integer32,
mltStatusTipVoltage Integer32,
mltStatusRingVoltage Integer32,
mltStatusTipRingVoltage Integer32,
mltStatusVdd Integer32
}
mltStatusAlarm OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates GNK and/or OTEMP alarms active when
status test was run."
::= { mltStatusResultsEntry 1 }
mltStatusHookState OBJECT-TYPE
SYNTAX MltTestHookState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates line hook state when status test was
run."
::= { mltStatusResultsEntry 2 }
mltStatusTransversalCurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates transversal current when status test
was run."
::= { mltStatusResultsEntry 3 }
mltStatusLongitudinalCurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates Longitudinal current when status test
was run."
::= { mltStatusResultsEntry 4 }
mltStatusTipVoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates tip voltage when status test was run."
::= { mltStatusResultsEntry 5 }
mltStatusRingVoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates ring voltage when status test was run."
::= { mltStatusResultsEntry 6 }
mltStatusTipRingVoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates tip-ring voltage when status test was
run."
::= { mltStatusResultsEntry 7 }
mltStatusVdd OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates Vdd when status test was run."
::= { mltStatusResultsEntry 8 }
-- mlt test results table
mltTestResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MltTestResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides result of the mlt test suite.
Note that a numerical result value of -999 means
that there was an error of some sort and the
value could not be measured.
Also, a resistance value of 9999 means that the
result was greater than 1000 kOhms, but the exact
value could not be measured."
::= { mltTestResults 2 }
mltTestResultsEntry OBJECT-TYPE
SYNTAX MltTestResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry holding information about results
of mlt suite tests."
INDEX { mltTestPort }
::= { mltTestResultsTable 1 }
MltTestResultsEntry ::= SEQUENCE {
mltTestAlarm OCTET STRING,
mltTestHookState MltTestHookState,
mltTestVdd Integer32,
mltTestActiveModeVoltagesVdctr Integer32,
mltTestActiveModeVoltagesVdctg Integer32,
mltTestActiveModeVoltagesVdcrg Integer32,
mltTestActiveModeVoltagesVactr Integer32,
mltTestActiveModeVoltagesVactg Integer32,
mltTestActiveModeVoltagesVacrg Integer32,
mltTestHighImpedanceModeVoltagesVdctr Integer32,
mltTestHighImpedanceModeVoltagesVdctg Integer32,
mltTestHighImpedanceModeVoltagesVdcrg Integer32,
mltTestHighImpedanceModeVoltagesVactr Integer32,
mltTestHighImpedanceModeVoltagesVactg Integer32,
mltTestHighImpedanceModeVoltagesVacrg Integer32,
mltTestDcCurrentsItransversal Integer32,
mltTestDcCurrentsIlongitudinal Integer32,
mltTestDcCurrentsItip Integer32,
mltTestDcCurrentsIring Integer32,
mltTestCapacitanceCeqtr Integer32,
mltTestCapacitanceCeqtg Integer32,
mltTestCapacitanceCeqrg Integer32,
mltTestResistanceRtr Integer32,
mltTestResistanceRtg Integer32,
mltTestResistanceRrg Integer32,
mltTestGr909HazardousPotentialTestResult MltTestPassFail,
mltTestGr909ForeignEmfTestResult MltTestPassFail,
mltTestGr909FuseTestTipFuse MltTestPassFail,
mltTestGr909FuseTestRingFuse MltTestPassFail,
mltTestFuseTestTipFuse MltTestPassFail,
mltTestFuseTestRingFuse MltTestPassFail,
mltTestGr909ResistiveFaultTestResult MltTestPassFail,
mltTestGr909ReceiverOffhookTestResult MltTestPassFail,
mltTestGr909ReceiverOffhookTestResistance1 Integer32,
mltTestGr909ReceiverOffhookTestResistance2 Integer32,
mltTestGr909ReceiverOffhookTestDifference Integer32,
mltTestGr909RingerTestResult MltTestRingerResult,
mltTestGr909RingerTestRen Integer32,
mltTestErrors OCTET STRING
}
mltTestAlarm OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"GNK and OTEMP bits set by the DuSLIC will be
reported as alarms. GNK is typically cause by
ground fault or foreign voltage condition.
OTEMP is set when the DuSLIC is experiencing
thermal overload. This parameter is
non-intrusive."
::= { mltTestResultsEntry 1 }
mltTestHookState OBJECT-TYPE
SYNTAX MltTestHookState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hook state reflects the DuSLIC hook bit
(offhook/onhook). This parameter is
non-intrusive."
::= { mltTestResultsEntry 2 }
mltTestVdd OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"On HDPOTS, internal Voltage VDD will be
reported and compared to statistically derived
thresholds.
This parameter is intrusive during offhook but
will be available during onhook."
::= { mltTestResultsEntry 3 }
mltTestActiveModeVoltagesVdctr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring
in a normal no shutdown state. AC voltages for
T-R, T-G and R-G will be reported.
Active mode measurements will not be available
when alarm is detected. This parameter is
intrusive and will be available in shutdown
state only."
::= { mltTestResultsEntry 4 }
mltTestActiveModeVoltagesVdctg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring
in a normal no shutdown state. AC voltages for
T-R, T-G and R-G will be reported.
Active mode measurements will not be available
when alarm is detected. This parameter is
intrusive and will be available in shutdown
state only."
::= { mltTestResultsEntry 5 }
mltTestActiveModeVoltagesVdcrg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring
in a normal no shutdown state. AC voltages for
T-R, T-G and R-G will be reported.
Active mode measurements will not be available
when alarm is detected. This parameter is
intrusive and will be available in shutdown
state only."
::= { mltTestResultsEntry 6 }
mltTestActiveModeVoltagesVactr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring
in a normal no shutdown state. Thus, VT and VR
measurements should be 0 volt.
AC voltages for T-R, T-G and R-G will be
reported. Active mode measurements will not be
available when alarm is detected. This parameter
is intrusive and will be available in shutdown
state only."
::= { mltTestResultsEntry 7 }
mltTestActiveModeVoltagesVactg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring
in a normal no shutdown state. Thus, VT and VR
measurements should be 0 volt. AC voltages for T-R, T-G
and R-G will be reported. Active mode measurements will
not be available when alarm is detected. This parameter
is intrusive and will be available in shutdown state
only."
::= { mltTestResultsEntry 8 }
mltTestActiveModeVoltagesVacrg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring in a
normal no shutdown state. Thus, VT and VR measurements
should be 0 volt. AC voltages for T-R, T-G and R-G will
be reported. Active mode measurements will not be
available when alarm is detected. This parameter is
intrusive and will be available in shutdown state only."
::= { mltTestResultsEntry 9 }
mltTestHighImpedanceModeVoltagesVdctr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring DC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. DC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltTestResultsEntry 10 }
mltTestHighImpedanceModeVoltagesVdctg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring DC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. DC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltTestResultsEntry 11 }
mltTestHighImpedanceModeVoltagesVdcrg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring DC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. DC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltTestResultsEntry 12 }
mltTestHighImpedanceModeVoltagesVactr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring AC Voltages (Foreign
Voltages): In this mode, the DuSLIC tip and ring are in
high impedance. The measured voltages represent foreign
voltages. AC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltTestResultsEntry 13 }
mltTestHighImpedanceModeVoltagesVactg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring AC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. AC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltTestResultsEntry 14 }
mltTestHighImpedanceModeVoltagesVacrg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring AC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. AC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltTestResultsEntry 15 }
mltTestDcCurrentsItransversal OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Four DC currents will be reported: IT, IL, It and Ir.
In normal condition, currents will be measured in
active mode. These measurements will not be available if
alarm is present."
::= { mltTestResultsEntry 16 }
mltTestDcCurrentsIlongitudinal OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Four DC currents will be reported: IT, IL, It and Ir.
In normal condition, currents will be measured in active
mode. These measurements will not be available if alarm
is present."
::= { mltTestResultsEntry 17 }
mltTestDcCurrentsItip OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Four DC currents will be reported: IT, IL, It and Ir.
In normal condition, currents will be measured in active
mode. These measurements will not be available if alarm
is present."
::= { mltTestResultsEntry 18 }
mltTestDcCurrentsIring OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Four DC currents will be reported: IT, IL, It and Ir.
In normal condition, currents will be measured in active
mode. These measurements will not be available if alarm
is present."
::= { mltTestResultsEntry 19 }
mltTestCapacitanceCeqtr OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Capacitance measurements will support only single
element (2 terminal) circuit. In the presence of a
network of capacitance (figure 3), the individual
capacitance will not be resolved. The equivalent
capacitances CEQtr, CEQtg and CEQrg will be reported.
They represent the following:
CEQtr = Ctr + Ctg/4 + Crg/4
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
Capacitance measurements will not be available if fuse
test fails or alarm is present. This test is intrusive
and will be available in shutdown state only."
::= { mltTestResultsEntry 20 }
mltTestCapacitanceCeqtg OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Capacitance measurements will support only single
element (2 terminal)
circuit. In the presence of a network of capacitance
(figure 3), the
individual capacitance will not be resolved. The
equivalent capacitances CEQtr, CEQtg and CEQrg will be
reported. They represent the following:
CEQtr = Ctr + Ctg/4 + Crg/4
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
Capacitance measurements will not be available if fuse
test fails or alarm is present. This test is intrusive
and will be available in shutdown state only."
::= { mltTestResultsEntry 21 }
mltTestCapacitanceCeqrg OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Capacitance measurements will support only single
element (2 terminal) circuit. In the presence of a
network of capacitance (figure 3), the individual
capacitance will not be resolved. The equivalent
capacitances CEQtr, CEQtg and CEQrg will be reported.
They represent the following:
CEQtr = Ctr + Ctg/4 + Crg/4
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
Capacitance measurements will not be available if fuse
test fails or alarm is present. This test is intrusive
and will be available in shutdown state only."
::= { mltTestResultsEntry 22 }
mltTestResistanceRtr OBJECT-TYPE
SYNTAX Integer32
UNITS "Ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DC resistance measurements will be based on a 3
terminal circuit model. Rtr, Rtg and Rrg will be
provided. User will have the option of specifying 3
resistance ranges: (1) low, (2) medium, (3) high. If not
specified, auto mode will be used. Resistance
measurements will not be available if fuse test fails or
alarm is present. This parameter is intrusive. This test
is intrusive and will be available in shutdown state `
only."
::= { mltTestResultsEntry 23 }
mltTestResistanceRtg OBJECT-TYPE
SYNTAX Integer32
UNITS "Ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DC resistance measurements will be based on a 3
terminal circuit model. Rtr, Rtg and Rrg will be
provided. User will have the option of specifying
3 resistance ranges: (1) low, (2) medium, (3) high. If
not specified, auto mode will be used. Resistance
measurements will not be available if fuse test fails or
alarm is present. This parameter is intrusive. This test
is intrusive and will be available in shutdown state
only."
::= { mltTestResultsEntry 24 }
mltTestResistanceRrg OBJECT-TYPE
SYNTAX Integer32
UNITS "Ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DC resistance measurements will be based on a 3
terminal circuit model. Rtr, Rtg and Rrg will be
provided. User will have the option of specifying
3 resistance ranges: (1) low, (2) medium, (3) high. If
not specified, auto mode will be used. Resistance
measurements will not be available if fuse test fails or
alarm is present. This parameter is intrusive. This test
is intrusive and will be available in shutdown state
only."
::= { mltTestResultsEntry 25 }
mltTestGr909HazardousPotentialTestResult OBJECT-TYPE
SYNTAX MltTestPassFail
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test fails if the T-G or R-G ac voltage is greater
than 50 volts rms or the T-G or R-G dc voltage is
greater than 135 volts. This test will report pass/fail.
This test is intrusive and will be available in shutdown
state only."
::= { mltTestResultsEntry 26 }
mltTestGr909ForeignEmfTestResult OBJECT-TYPE
SYNTAX MltTestPassFail
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test fails if the T-G or R-G ac voltage is greater
than 50 volts rms or the T-G or R-G dc voltage is
greater than 135 volts. This test will report pass/fail.
This test is intrusive and will be available in shutdown
state only."
::= { mltTestResultsEntry 27 }
mltTestGr909FuseTestTipFuse OBJECT-TYPE
SYNTAX MltTestPassFail
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This test determines if these fuses are blown. This
test will return pass/fail for tip and ring. This test
will not be performed if alarm is present. This
parameter is intrusive. This test is intrusive and will
be available in shutdown state only.
This object is obsolete. Object name was changed."
::= { mltTestResultsEntry 28 }
mltTestGr909FuseTestRingFuse OBJECT-TYPE
SYNTAX MltTestPassFail
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This test determines if these fuses are blown. This
test will return pass/fail for tip and ring. This test
will not be performed if alarm is present. This
parameter is intrusive. This test is intrusive and will
be available in shutdown state only.
This object is obsolete. Object name was changed."
::= { mltTestResultsEntry 29 }
mltTestFuseTestTipFuse OBJECT-TYPE
SYNTAX MltTestPassFail
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test determines if these fuses are blown. This
test will return pass/fail for tip and ring. This test
will not be performed if alarm is present. This
parameter is intrusive. This test is intrusive and will
be available in shutdown state only."
::= { mltTestResultsEntry 38 }
mltTestFuseTestRingFuse OBJECT-TYPE
SYNTAX MltTestPassFail
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test determines if these fuses are blown. This
test will return pass/fail for tip and ring. This test
will not be performed if alarm is present. This
parameter is intrusive. This test is intrusive and will
be available in shutdown state only."
::= { mltTestResultsEntry 39 }
mltTestGr909ResistiveFaultTestResult OBJECT-TYPE
SYNTAX MltTestPassFail
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test fails if the T-R, T-G or R-G dc resistance is
less than 150k ohm. This test will not be performed if
fuse test fails or alarm is present. This test will
return pass/fail. This test is intrusive and will be
available in shutdown state only."
::= { mltTestResultsEntry 30 }
mltTestGr909ReceiverOffhookTestResult OBJECT-TYPE
SYNTAX MltTestPassFail
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test fails if a non-linearity in the T-R dc
resistance of greater than 15% when measured at two
different voltage levels exists. This test will not be
performed if fuse test fails or alarm is present. This
test will return the DC resistances at two different
operating points and the percent difference between the
two DC resistances. This test is intrusive and will be
available in shutdown state only. "
::= { mltTestResultsEntry 31 }
mltTestGr909ReceiverOffhookTestResistance1 OBJECT-TYPE
SYNTAX Integer32
UNITS "Ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test fails if a non-linearity in the T-R dc
resistance of greater than 15% when measured at two
different voltage levels exists. This test will not be
performed if fuse test fails or alarm is present. This
test will return the DC resistances at two different
operating points and the percent difference between the
two DC resistances. This test is intrusive and will be
available in shutdown state only. "
::= { mltTestResultsEntry 32 }
mltTestGr909ReceiverOffhookTestResistance2 OBJECT-TYPE
SYNTAX Integer32
UNITS "Ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test fails if a non-linearity in the T-R dc
resistance of greater than 15% when measured at two
different voltage levels exists. This test will not be
performed if fuse test fails or alarm is present. This
test will return the DC resistances at two different
operating points and the percent difference between the
two DC resistances. This test is intrusive and will be
available in shutdown state only. "
::= { mltTestResultsEntry 33 }
mltTestGr909ReceiverOffhookTestDifference OBJECT-TYPE
SYNTAX Integer32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test fails if a non-linearity in the T-R dc
resistance of greater than 15% when measured at two
different voltage levels exists. This test will not be
performed if fuse test fails or alarm is present. This
test will return the DC resistances at two different
operating points and the percent difference between the
two DC resistances. This test is intrusive and will be
available in shutdown state only. "
::= { mltTestResultsEntry 34 }
mltTestGr909RingerTestResult OBJECT-TYPE
SYNTAX MltTestRingerResult
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test fails when the equivalent ringer count across
tip and ring is less than 0.175 REN or greater than 5
REN. This test will not run if fuse test fails or alarm
is present. This test will report passed/fail and the
REN number. This parameter is intrusive and will be
available in shutdown state shutdown only."
::= { mltTestResultsEntry 35 }
mltTestGr909RingerTestRen OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 REN"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test fails when the equivalent ringer count across
tip and ring is less than 0.175 REN or greater than 5
REN. This test will not run if fuse test fails or alarm
is present. This test will report passed/fail and the
REN number. This parameter is intrusive and will be
available in shutdown state shutdown only."
::= { mltTestResultsEntry 36 }
mltTestErrors OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates GNK and/or OTEMP alarms active when test was
run."
::= { mltTestResultsEntry 37 }
-- mlt active mode voltages results table
mltActiveModeVoltagesResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MltActiveModeVoltagesResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides results of the mlt active mode
voltages test.
Note that a numerical result value of -999 means that
there was an error of some sort and the value could not
be measured."
::= { mltTestResults 3 }
mltActiveModeVoltagesResultsEntry OBJECT-TYPE
SYNTAX MltActiveModeVoltagesResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry holding information about results
of mlt active mode voltages test."
INDEX { mltTestPort }
::= { mltActiveModeVoltagesResultsTable 1 }
MltActiveModeVoltagesResultsEntry ::= SEQUENCE {
mltActiveModeVoltagesVdctr Integer32,
mltActiveModeVoltagesVdctg Integer32,
mltActiveModeVoltagesVdcrg Integer32,
mltActiveModeVoltagesVactr Integer32,
mltActiveModeVoltagesVactg Integer32,
mltActiveModeVoltagesVacrg Integer32,
mltActiveModeVoltagesErrors OCTET STRING
}
mltActiveModeVoltagesVdctr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring in a
normal no shutdown state. AC voltages for T-R, T-G and
R-G will be reported.
Active mode measurements will not be available when
alarm is detected. This parameter is intrusive and will
be available in shutdown state only."
::= { mltActiveModeVoltagesResultsEntry 1 }
mltActiveModeVoltagesVdctg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring in a
normal no shutdown state. AC voltages for T-R, T-G and
R-G will be reported. Active mode measurements will not
be available when alarm is detected. This parameter is
intrusive and will be available in shutdown state only."
::= { mltActiveModeVoltagesResultsEntry 2 }
mltActiveModeVoltagesVdcrg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring in a
normal no shutdown state. AC voltages for T-R, T-G and
R-G will be reported. Active mode measurements will not
be available when alarm is detected. This parameter is
intrusive and will be available in shutdown state only."
::= { mltActiveModeVoltagesResultsEntry 3 }
mltActiveModeVoltagesVactr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring in a
normal no shutdown state. Thus, VT and VR measurements
should be 0 volt. AC voltages for T-R, T-G and R-G will
be reported. Active mode measurements will not be
available when alarm is detected. This parameter is
intrusive and will be available in shutdown state only."
::= { mltActiveModeVoltagesResultsEntry 4 }
mltActiveModeVoltagesVactg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring in a
normal no shutdown state. Thus, VT and VR measurements
should be 0 volt. AC voltages for T-R, T-G and R-G will
be reported. Active mode measurements will not be
available when alarm is detected. This parameter is
intrusive and will be available in shutdown state only."
::= { mltActiveModeVoltagesResultsEntry 5 }
mltActiveModeVoltagesVacrg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring in a
normal no shutdown state. Thus, VT and VR measurements
should be 0 volt. AC voltages for T-R, T-G and R-G will
be reported.
Active mode measurements will not be available when
alarm is detected. This parameter is intrusive and will
be available in shutdown state only."
::= { mltActiveModeVoltagesResultsEntry 6 }
mltActiveModeVoltagesErrors OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates GNK and/or OTEMP alarms active when test was
run."
::= { mltActiveModeVoltagesResultsEntry 7 }
-- mlt high impedance mode voltages results table
mltHighImpedanceModeVoltagesResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF
MltHighImpedanceModeVoltagesResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides result of the mlt test suite.
Note that a numerical result value of -999 means that
there was an error of some sort and the value could not
be measured."
::= { mltTestResults 4 }
mltHighImpedanceModeVoltagesResultsEntry OBJECT-TYPE
SYNTAX MltHighImpedanceModeVoltagesResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry holding information about results
of mlt high impedance mode voltages test."
INDEX { mltTestPort }
::= { mltHighImpedanceModeVoltagesResultsTable 1 }
MltHighImpedanceModeVoltagesResultsEntry ::= SEQUENCE {
mltHighImpedanceModeVoltagesVdctr Integer32,
mltHighImpedanceModeVoltagesVdctg Integer32,
mltHighImpedanceModeVoltagesVdcrg Integer32,
mltHighImpedanceModeVoltagesVactr Integer32,
mltHighImpedanceModeVoltagesVactg Integer32,
mltHighImpedanceModeVoltagesVacrg Integer32,
mltHighImpedanceModeVoltagesErrors OCTET STRING
}
mltHighImpedanceModeVoltagesVdctr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring DC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. DC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltHighImpedanceModeVoltagesResultsEntry 1 }
mltHighImpedanceModeVoltagesVdctg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring DC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. DC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltHighImpedanceModeVoltagesResultsEntry 2 }
mltHighImpedanceModeVoltagesVdcrg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring DC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. DC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltHighImpedanceModeVoltagesResultsEntry 3 }
mltHighImpedanceModeVoltagesVactr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring AC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. AC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltHighImpedanceModeVoltagesResultsEntry 4 }
mltHighImpedanceModeVoltagesVactg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring AC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. AC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltHighImpedanceModeVoltagesResultsEntry 5 }
mltHighImpedanceModeVoltagesVacrg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring AC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. AC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltHighImpedanceModeVoltagesResultsEntry 6 }
mltHighImpedanceModeVoltagesErrors OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates GNK and/or OTEMP alarms active when test was
run."
::= { mltHighImpedanceModeVoltagesResultsEntry 7 }
-- mlt DC resistance results table
mltDcResistanceResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MltDcResistanceResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides result of the DC resistance test.
Note that a numerical result value of -999 means that
there was an error of some sort and the value could not
be measured. Also, a resistance value of 9999 means
that the result was greater than 1000 kOhms, but the
exact value could not be measured."
::= { mltTestResults 5 }
mltDcResistanceResultsEntry OBJECT-TYPE
SYNTAX MltDcResistanceResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry holding information about results
of mlt DC resistance test."
INDEX { mltTestPort }
::= { mltDcResistanceResultsTable 1 }
MltDcResistanceResultsEntry ::= SEQUENCE {
mltDcResistanceRtr Integer32,
mltDcResistanceRtg Integer32,
mltDcResistanceRrg Integer32,
mltDcResistanceErrors OCTET STRING
}
mltDcResistanceRtr OBJECT-TYPE
SYNTAX Integer32
UNITS "Ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DC resistance measurements will be based on a 3
terminal circuit model. Rtr, Rtg and Rrg will be
provided. User will have the option of specifying
3 resistance ranges: (1) low, (2) medium, (3) high. If
not specified, auto mode will be used. Resistance
measurements will not be available if fuse test fails or
alarm is present. This parameter is intrusive. This test
is intrusive and will be available in shutdown state
only."
::= { mltDcResistanceResultsEntry 1 }
mltDcResistanceRtg OBJECT-TYPE
SYNTAX Integer32
UNITS "Ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DC resistance measurements will be based on a 3
terminal circuit model. Rtr, Rtg and Rrg will be
provided. User will have the option of specifying
3 resistance ranges: (1) low, (2) medium, (3) high. If
not specified, auto mode will be used. Resistance
measurements will not be available if fuse test fails or
alarm is present. This parameter is intrusive. This test
is intrusive and will be available in shutdown state
only."
::= { mltDcResistanceResultsEntry 2 }
mltDcResistanceRrg OBJECT-TYPE
SYNTAX Integer32
UNITS "Ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DC resistance measurements will be based on a 3
terminal circuit model. Rtr, Rtg and Rrg will be
provided. User will have the option of specifying
3 resistance ranges: (1) low, (2) medium, (3) high. If
not specified, auto mode will be used. Resistance
measurements will not be available if fuse test fails or
alarm is present. This parameter is intrusive. This test
is intrusive and will be available in shutdown state
only."
::= { mltDcResistanceResultsEntry 3 }
mltDcResistanceErrors OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates GNK and/or OTEMP alarms active when test was
run."
::= { mltDcResistanceResultsEntry 4 }
-- mlt capacitance results table
mltCapacitanceResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MltCapacitanceResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides result of the mlt test suite.
Note that a numerical result value of -999 means that
there was an error of some sort and the value could not
be measured."
::= { mltTestResults 6 }
mltCapacitanceResultsEntry OBJECT-TYPE
SYNTAX MltCapacitanceResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry holding information about results
of mlt capacitance test."
INDEX { mltTestPort }
::= { mltCapacitanceResultsTable 1 }
MltCapacitanceResultsEntry ::= SEQUENCE {
mltCapacitanceCeqtr Integer32,
mltCapacitanceCeqtg Integer32,
mltCapacitanceCeqrg Integer32,
mltCapacitanceErrors OCTET STRING
}
mltCapacitanceCeqtr OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Capacitance measurements will support only single
element (2 terminal) circuit. In the presence of a
network of capacitance (figure 3), the individual
capacitance will not be resolved. The equivalent
capacitances CEQtr, CEQtg and CEQrg will be reported.
They represent the following:
CEQtr = Ctr + Ctg/4 + Crg/4
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
Capacitance measurements will not be available if fuse
test fails or alarm is present. This test is intrusive
and will be available in shutdown state only."
::= { mltCapacitanceResultsEntry 1 }
mltCapacitanceCeqtg OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Capacitance measurements will support only single
element (2 terminal) circuit. In the presence of a
network of capacitance (figure 3), the individual
capacitance will not be resolved. The equivalent
capacitances CEQtr, CEQtg and CEQrg will be reported.
They represent the following:
CEQtr = Ctr + Ctg/4 + Crg/4
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
Capacitance measurements will not be available if fuse
test fails or alarm is present. This test is intrusive
and will be available in shutdown state only."
::= { mltCapacitanceResultsEntry 2 }
mltCapacitanceCeqrg OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Capacitance measurements will support only single
element (2 terminal) circuit. In the presence of a
network of capacitance (figure 3), the individual
capacitance will not be resolved. The equivalent
capacitances CEQtr, CEQtg and CEQrg will be reported.
They represent the following:
CEQtr = Ctr + Ctg/4 + Crg/4
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
Capacitance measurements will not be available if fuse
test fails or alarm is present. This test is intrusive
and will be available in shutdown state only."
::= { mltCapacitanceResultsEntry 3 }
mltCapacitanceErrors OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates GNK and/or OTEMP alarms active when test was
run."
::= { mltCapacitanceResultsEntry 4 }
-- mlt loop detect results table
mltLoopDetectResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MltLoopDetectResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides result of the mlt loop detect test.
Note that a numerical result value of -999 means that
there was an error of some sort and the value could not
be measured."
::= { mltTestResults 7 }
mltLoopDetectResultsEntry OBJECT-TYPE
SYNTAX MltLoopDetectResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry holding information about results
of mlt loop detect test."
INDEX { mltTestPort }
::= { mltLoopDetectResultsTable 1 }
MltLoopDetectResultsEntry ::= SEQUENCE {
mltLoopDetectLoopCapacitance Integer32,
mltLoopDetectDetectionThreshold Integer32,
mltLoopDetectLoopDetected MltTestYesNo,
mltLoopDetectErrors OCTET STRING
}
mltLoopDetectLoopCapacitance OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop detection will be based on tip-ring capacitance
measurement. User will be able to specify the detection
threshold. If not supplied,loop detection threshold of
10 nF will be used. This test will not be available if
fuse test fails or alarm is present. This test is
intrusive and will be available in shutdown state only."
::= { mltLoopDetectResultsEntry 1 }
mltLoopDetectDetectionThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop detection will be based on tip-ring capacitance
measurement. User will be able to specify the detection
threshold. If not supplied, loop detection threshold of
10 nF will be used. This test will not be available if
fuse test fails or alarm is present. This test is
intrusive and will be available in shutdown state only."
::= { mltLoopDetectResultsEntry 2 }
mltLoopDetectLoopDetected OBJECT-TYPE
SYNTAX MltTestYesNo
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop detection will be based on tip-ring capacitance
measurement. User will be able to specify the detection
threshold. If not supplied, loop detection threshold
of 10 nF will be used. This test will not be available
if fuse test fails or alarm is present. This test is
intrusive and will be available in shutdown state only."
::= { mltLoopDetectResultsEntry 3 }
mltLoopDetectErrors OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates GNK and/or OTEMP alarms active when test
was run."
::= { mltLoopDetectResultsEntry 4 }
-- mlt loop length results table
mltLoopLengthResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MltLoopLengthResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides result of the mlt loop length test.
Note that a numerical result value of -999 means that
there was an error of some sort and the value could
not be measured."
::= { mltTestResults 8 }
mltLoopLengthResultsEntry OBJECT-TYPE
SYNTAX MltLoopLengthResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry holding information about results
of mlt loop length test."
INDEX { mltTestPort }
::= { mltLoopLengthResultsTable 1 }
MltLoopLengthResultsEntry ::= SEQUENCE {
mltLoopLengthCapacitanceFactor Integer32,
mltLoopLengthLoopCapacitance Integer32,
mltLoopLengthLoopLength Integer32,
mltLoopLengthUncompensatedLoopCapacitance Integer32,
mltLoopLengthUncompensatedLoopLength Integer32,
mltLoopLengthErrors OCTET STRING
}
mltLoopLengthCapacitanceFactor OBJECT-TYPE
SYNTAX Integer32
UNITS "nF/mile"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop length estimate will be based on tip-ring
capacitance measurement. User will be able to
specify the loop length multiplier. If not supplied,
loop length multiplier of 83 nF/ mile will be used.
This test will not be available if fuse test fails
or alarm is present. This test is intrusive and will
be available in shutdown state only."
::= { mltLoopLengthResultsEntry 1 }
mltLoopLengthLoopCapacitance OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop length estimate will be based on tip-ring
capacitance measurement. User will be able to specify
the loop length multiplier. If not supplied, loop length
multiplier of 83 nF/ mile will be used. This test will
not be available if fuse test fails or alarm is present.
This test is intrusive and will be available in shutdown
state only. "
::= { mltLoopLengthResultsEntry 2 }
mltLoopLengthLoopLength OBJECT-TYPE
SYNTAX Integer32
UNITS "ft"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop length estimate will be based on tip-ring
capacitance measurement. User will be able to specify
the loop length multiplier. If not supplied, loop length
multiplier of 83 nF/ mile will be used. This test will
not be available if fuse test fails or alarm is present.
This test is intrusive and will be available in shutdown
state only. "
::= { mltLoopLengthResultsEntry 3 }
mltLoopLengthUncompensatedLoopCapacitance OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop length estimate will be based on tip-ring
capacitance measurement. User will be able to specify
the loop length multiplier. If not supplied, loop length
multiplier of 83 nF/ mile will be used. This test will
not be available if fuse test fails or alarm is present.
This test is intrusive and will be available in shutdown
state only. This value has no DSL correction."
::= { mltLoopLengthResultsEntry 4 }
mltLoopLengthUncompensatedLoopLength OBJECT-TYPE
SYNTAX Integer32
UNITS "ft"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop length estimate will be based on tip-ring
capacitance measurement. User will be able to specify
the loop length multiplier. If not supplied, loop length
multiplier of 83 nF/ mile will be used. This test will
not be available if fuse test fails or alarm is present.
This test is intrusive and will be available in shutdown
state only. This value has no DSL correction."
::= { mltLoopLengthResultsEntry 5 }
mltLoopLengthErrors OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates GNK and/or OTEMP alarms active when test was
run."
::= { mltLoopLengthResultsEntry 6 }
-- notifications
mltTestCompletedNotification NOTIFICATION-TYPE
OBJECTS { mltTestIdentifier, mltTestPort,
mltLastTestStatus, mltErrorText }
STATUS current
DESCRIPTION
"This notification is sent to the
requesting host when the requested mlt
test has completed."
::= { mltTestNotifications 1 }
END