OCCAM-MLT-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
occamGenericMonitorModules
|
|
FROM OCCAM-REG-MODULE
|
|
TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY,
|
|
Integer32, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI;
|
|
|
|
occamMltMib MODULE-IDENTITY
|
|
LAST-UPDATED "200104271051Z"
|
|
ORGANIZATION "Occam Networks"
|
|
CONTACT-INFO "email support@occamnetworks.com"
|
|
DESCRIPTION
|
|
"This mib module describes objects used
|
|
to perform Metallic Line Testing on customer
|
|
access lines and to provide results."
|
|
|
|
REVISION "200104271051Z"
|
|
DESCRIPTION "Reformatted certain text"
|
|
|
|
REVISION "200704170000Z"
|
|
DESCRIPTION "replace kOhm with Ohm in DC resistance
|
|
UNITS"
|
|
|
|
REVISION "200702220000Z"
|
|
DESCRIPTION "remove DISPLAY-HINT"
|
|
|
|
REVISION "200609261000Z"
|
|
DESCRIPTION "Removed Gr909 from fuse test result names"
|
|
|
|
REVISION "200602220135Z"
|
|
DESCRIPTION "Initial version."
|
|
::= { occamGenericMonitorModules 3 }
|
|
|
|
-- TEXTUAL-CONVENTIONS --
|
|
|
|
MltTestType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A selection value for requesting or forcing
|
|
a test. A requested test will only run if the
|
|
port is not in use. A forced test will
|
|
immediately shut the port and run the test."
|
|
SYNTAX INTEGER { request ( 1 ) ,
|
|
force ( 2 ) }
|
|
|
|
MltTestStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An indication of test status:
|
|
none = no test has been requested.
|
|
mltbusy = another port is currently being tested.
|
|
complete = the last requested test has completed.
|
|
portInUse = the last requested port is in use,
|
|
the test was not run. Rerunning the test as
|
|
'forced' will shut the port and run the test.
|
|
inProgress = the last requested test is still
|
|
running. mltError = the mlt program reported an
|
|
error and aborted the test.Check the mltErrorText
|
|
object.
|
|
mltNotResponding = the mlt program didn't return
|
|
a result."
|
|
SYNTAX INTEGER {
|
|
none ( 1 ) ,
|
|
mltBusy ( 2 ),
|
|
complete ( 3 ) ,
|
|
portInUse ( 4 ) ,
|
|
inProgress ( 5 ),
|
|
mltError ( 6 ),
|
|
mltNotResponding ( 7 ) }
|
|
|
|
MltTestIdentifier ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An mlt test selection value."
|
|
SYNTAX INTEGER {
|
|
statusSuite ( 1 ) ,
|
|
mltSuite ( 2 ) ,
|
|
activeModeVoltages ( 3 ) ,
|
|
highImpedanceModeVoltages ( 4 ) ,
|
|
dcResistance ( 5 ) ,
|
|
capacitance ( 6 ) ,
|
|
loopDetect ( 7 ) ,
|
|
loopLength ( 8 ) }
|
|
|
|
MltTestHookState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An mlt test hook state value."
|
|
SYNTAX INTEGER {
|
|
onhook ( 1 ) ,
|
|
offhook ( 2 ),
|
|
notAvailable ( 3 ) }
|
|
|
|
MltTestPassFail ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An mlt test pass/fail value."
|
|
SYNTAX INTEGER {
|
|
pass ( 1 ) ,
|
|
fail ( 2 ),
|
|
notAvailable ( 3 ) }
|
|
|
|
MltTestRingerResult ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An mlt ringer test result value."
|
|
SYNTAX INTEGER {
|
|
pass ( 1 ) ,
|
|
fail ( 2 ),
|
|
notAvailable ( 3 ),
|
|
low ( 4 ) }
|
|
|
|
MltTestYesNo ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An mlt test pass/fail value."
|
|
SYNTAX INTEGER {
|
|
yes ( 1 ) ,
|
|
no ( 2 ),
|
|
notAvailable ( 3 ) }
|
|
|
|
-- The Metallic Loop Test Configuration group
|
|
|
|
mltTestConfig OBJECT IDENTIFIER
|
|
::= { occamMltMib 1 }
|
|
|
|
|
|
-- The Metallic Loop Test Status group
|
|
|
|
mltTestStatus OBJECT IDENTIFIER
|
|
::= { occamMltMib 2 }
|
|
|
|
|
|
-- The Metallic Loop Test Results group
|
|
|
|
mltTestResults OBJECT IDENTIFIER
|
|
::= { occamMltMib 3 }
|
|
|
|
-- The Metallic Loop Test Notifications group
|
|
|
|
mltTestNotifications OBJECT IDENTIFIER
|
|
::= { occamMltMib 4 }
|
|
|
|
|
|
-- Objects of the MLT Configuration group
|
|
|
|
mltTestIdentifier OBJECT-TYPE
|
|
SYNTAX MltTestIdentifier
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects the mlt test to be run.
|
|
Setting this value starts a test.
|
|
|
|
This is a required parameter.
|
|
|
|
Approximate expected test durations are as
|
|
follows:
|
|
|
|
statusSuite 1 second
|
|
mltSuite 1 minute
|
|
activeModeVoltages 3 seconds
|
|
highImpedanceModeVoltages 9 seconds
|
|
dcResistance 18 seconds
|
|
capacitance 18 seconds
|
|
loopDetect 9 seconds
|
|
loopLength 9 seconds."
|
|
::= { mltTestConfig 1 }
|
|
|
|
mltTestType OBJECT-TYPE
|
|
SYNTAX MltTestType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects if a test is requested (only run if port
|
|
is not in use) or forced.
|
|
This is an optional parameter. If not specified,
|
|
the request option is used."
|
|
::= { mltTestConfig 2 }
|
|
|
|
mltTestPort OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1 .. 48 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects voice channel on which test will be run.
|
|
This is a required parameter."
|
|
::= { mltTestConfig 3 }
|
|
|
|
mltDcResistanceRange OBJECT-TYPE
|
|
SYNTAX Integer32 ( 0 .. 3 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects DC Resistance range value.
|
|
This is an optional paramater. Default is 0
|
|
(auto mode)."
|
|
::= { mltTestConfig 4 }
|
|
|
|
mltLoopLengthMultiplier OBJECT-TYPE
|
|
SYNTAX Integer32 ( 10 .. 200 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects loop length multiplier in nf. This is an
|
|
optional parameter. If not specified an internal
|
|
default value of 83nF/mile is used."
|
|
::= { mltTestConfig 5 }
|
|
|
|
mltLoopDetectThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 ( 5 .. 200 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects the detection threshold in nF.
|
|
This is an optional parameter. If not supplied,
|
|
a loop detection threshold of 10nF is used."
|
|
::= { mltTestConfig 6 }
|
|
|
|
|
|
-- Objects of the MLT Test Status group
|
|
|
|
mltLastTestStatus OBJECT-TYPE
|
|
SYNTAX MltTestStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the status of the last run mlt test.
|
|
Given that the various mlt tests take several
|
|
seconds to 1 1/2 minutes to run, it is suggested
|
|
that status polls be spaced 10-20 seconds apart.
|
|
Additionally, a monitoring application could
|
|
wait for the testComplete notification."
|
|
::= { mltTestStatus 1 }
|
|
|
|
mltErrorText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the textual error in the case of an
|
|
aborted test."
|
|
::= { mltTestStatus 2 }
|
|
|
|
|
|
-- Objects of the MLT Test Results group
|
|
|
|
-- mlt status results table
|
|
mltStatusResultsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MltStatusResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides result of the status test
|
|
suite."
|
|
::= { mltTestResults 1 }
|
|
|
|
mltStatusResultsEntry OBJECT-TYPE
|
|
SYNTAX MltStatusResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry holding information about results
|
|
of status suite tests.
|
|
|
|
Note that a numerical result value of -999 means
|
|
that there was an error of some sort and the
|
|
value could not be measured."
|
|
INDEX { mltTestPort }
|
|
::= { mltStatusResultsTable 1 }
|
|
|
|
MltStatusResultsEntry ::= SEQUENCE {
|
|
mltStatusAlarm OCTET STRING,
|
|
mltStatusHookState MltTestHookState,
|
|
mltStatusTransversalCurrent Integer32,
|
|
mltStatusLongitudinalCurrent Integer32,
|
|
mltStatusTipVoltage Integer32,
|
|
mltStatusRingVoltage Integer32,
|
|
mltStatusTipRingVoltage Integer32,
|
|
mltStatusVdd Integer32
|
|
}
|
|
|
|
|
|
mltStatusAlarm OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates GNK and/or OTEMP alarms active when
|
|
status test was run."
|
|
::= { mltStatusResultsEntry 1 }
|
|
|
|
|
|
mltStatusHookState OBJECT-TYPE
|
|
SYNTAX MltTestHookState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates line hook state when status test was
|
|
run."
|
|
::= { mltStatusResultsEntry 2 }
|
|
|
|
|
|
mltStatusTransversalCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 mA"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates transversal current when status test
|
|
was run."
|
|
::= { mltStatusResultsEntry 3 }
|
|
|
|
|
|
mltStatusLongitudinalCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 mA"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates Longitudinal current when status test
|
|
was run."
|
|
::= { mltStatusResultsEntry 4 }
|
|
|
|
|
|
mltStatusTipVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates tip voltage when status test was run."
|
|
::= { mltStatusResultsEntry 5 }
|
|
|
|
|
|
mltStatusRingVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates ring voltage when status test was run."
|
|
::= { mltStatusResultsEntry 6 }
|
|
|
|
mltStatusTipRingVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates tip-ring voltage when status test was
|
|
run."
|
|
::= { mltStatusResultsEntry 7 }
|
|
|
|
|
|
mltStatusVdd OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates Vdd when status test was run."
|
|
::= { mltStatusResultsEntry 8 }
|
|
|
|
-- mlt test results table
|
|
mltTestResultsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MltTestResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides result of the mlt test suite.
|
|
Note that a numerical result value of -999 means
|
|
that there was an error of some sort and the
|
|
value could not be measured.
|
|
Also, a resistance value of 9999 means that the
|
|
result was greater than 1000 kOhms, but the exact
|
|
value could not be measured."
|
|
::= { mltTestResults 2 }
|
|
|
|
mltTestResultsEntry OBJECT-TYPE
|
|
SYNTAX MltTestResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry holding information about results
|
|
of mlt suite tests."
|
|
INDEX { mltTestPort }
|
|
::= { mltTestResultsTable 1 }
|
|
|
|
MltTestResultsEntry ::= SEQUENCE {
|
|
mltTestAlarm OCTET STRING,
|
|
mltTestHookState MltTestHookState,
|
|
mltTestVdd Integer32,
|
|
mltTestActiveModeVoltagesVdctr Integer32,
|
|
mltTestActiveModeVoltagesVdctg Integer32,
|
|
mltTestActiveModeVoltagesVdcrg Integer32,
|
|
mltTestActiveModeVoltagesVactr Integer32,
|
|
mltTestActiveModeVoltagesVactg Integer32,
|
|
mltTestActiveModeVoltagesVacrg Integer32,
|
|
mltTestHighImpedanceModeVoltagesVdctr Integer32,
|
|
mltTestHighImpedanceModeVoltagesVdctg Integer32,
|
|
mltTestHighImpedanceModeVoltagesVdcrg Integer32,
|
|
mltTestHighImpedanceModeVoltagesVactr Integer32,
|
|
mltTestHighImpedanceModeVoltagesVactg Integer32,
|
|
mltTestHighImpedanceModeVoltagesVacrg Integer32,
|
|
mltTestDcCurrentsItransversal Integer32,
|
|
mltTestDcCurrentsIlongitudinal Integer32,
|
|
mltTestDcCurrentsItip Integer32,
|
|
mltTestDcCurrentsIring Integer32,
|
|
mltTestCapacitanceCeqtr Integer32,
|
|
mltTestCapacitanceCeqtg Integer32,
|
|
mltTestCapacitanceCeqrg Integer32,
|
|
mltTestResistanceRtr Integer32,
|
|
mltTestResistanceRtg Integer32,
|
|
mltTestResistanceRrg Integer32,
|
|
mltTestGr909HazardousPotentialTestResult MltTestPassFail,
|
|
mltTestGr909ForeignEmfTestResult MltTestPassFail,
|
|
mltTestGr909FuseTestTipFuse MltTestPassFail,
|
|
mltTestGr909FuseTestRingFuse MltTestPassFail,
|
|
mltTestFuseTestTipFuse MltTestPassFail,
|
|
mltTestFuseTestRingFuse MltTestPassFail,
|
|
mltTestGr909ResistiveFaultTestResult MltTestPassFail,
|
|
mltTestGr909ReceiverOffhookTestResult MltTestPassFail,
|
|
mltTestGr909ReceiverOffhookTestResistance1 Integer32,
|
|
mltTestGr909ReceiverOffhookTestResistance2 Integer32,
|
|
mltTestGr909ReceiverOffhookTestDifference Integer32,
|
|
mltTestGr909RingerTestResult MltTestRingerResult,
|
|
mltTestGr909RingerTestRen Integer32,
|
|
mltTestErrors OCTET STRING
|
|
}
|
|
|
|
|
|
mltTestAlarm OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"GNK and OTEMP bits set by the DuSLIC will be
|
|
reported as alarms. GNK is typically cause by
|
|
ground fault or foreign voltage condition.
|
|
OTEMP is set when the DuSLIC is experiencing
|
|
thermal overload. This parameter is
|
|
non-intrusive."
|
|
::= { mltTestResultsEntry 1 }
|
|
|
|
mltTestHookState OBJECT-TYPE
|
|
SYNTAX MltTestHookState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hook state reflects the DuSLIC hook bit
|
|
(offhook/onhook). This parameter is
|
|
non-intrusive."
|
|
::= { mltTestResultsEntry 2 }
|
|
|
|
mltTestVdd OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"On HDPOTS, internal Voltage VDD will be
|
|
reported and compared to statistically derived
|
|
thresholds.
|
|
This parameter is intrusive during offhook but
|
|
will be available during onhook."
|
|
::= { mltTestResultsEntry 3 }
|
|
|
|
mltTestActiveModeVoltagesVdctr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring
|
|
in a normal no shutdown state. AC voltages for
|
|
T-R, T-G and R-G will be reported.
|
|
Active mode measurements will not be available
|
|
when alarm is detected. This parameter is
|
|
intrusive and will be available in shutdown
|
|
state only."
|
|
::= { mltTestResultsEntry 4 }
|
|
|
|
mltTestActiveModeVoltagesVdctg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring
|
|
in a normal no shutdown state. AC voltages for
|
|
T-R, T-G and R-G will be reported.
|
|
Active mode measurements will not be available
|
|
when alarm is detected. This parameter is
|
|
intrusive and will be available in shutdown
|
|
state only."
|
|
::= { mltTestResultsEntry 5 }
|
|
|
|
mltTestActiveModeVoltagesVdcrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring
|
|
in a normal no shutdown state. AC voltages for
|
|
T-R, T-G and R-G will be reported.
|
|
Active mode measurements will not be available
|
|
when alarm is detected. This parameter is
|
|
intrusive and will be available in shutdown
|
|
state only."
|
|
::= { mltTestResultsEntry 6 }
|
|
|
|
mltTestActiveModeVoltagesVactr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring
|
|
in a normal no shutdown state. Thus, VT and VR
|
|
measurements should be 0 volt.
|
|
AC voltages for T-R, T-G and R-G will be
|
|
reported. Active mode measurements will not be
|
|
available when alarm is detected. This parameter
|
|
is intrusive and will be available in shutdown
|
|
state only."
|
|
::= { mltTestResultsEntry 7 }
|
|
|
|
mltTestActiveModeVoltagesVactg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring
|
|
in a normal no shutdown state. Thus, VT and VR
|
|
measurements should be 0 volt. AC voltages for T-R, T-G
|
|
and R-G will be reported. Active mode measurements will
|
|
not be available when alarm is detected. This parameter
|
|
is intrusive and will be available in shutdown state
|
|
only."
|
|
::= { mltTestResultsEntry 8 }
|
|
|
|
mltTestActiveModeVoltagesVacrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring in a
|
|
normal no shutdown state. Thus, VT and VR measurements
|
|
should be 0 volt. AC voltages for T-R, T-G and R-G will
|
|
be reported. Active mode measurements will not be
|
|
available when alarm is detected. This parameter is
|
|
intrusive and will be available in shutdown state only."
|
|
|
|
::= { mltTestResultsEntry 9 }
|
|
|
|
mltTestHighImpedanceModeVoltagesVdctr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring DC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. DC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltTestResultsEntry 10 }
|
|
|
|
mltTestHighImpedanceModeVoltagesVdctg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring DC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. DC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltTestResultsEntry 11 }
|
|
|
|
mltTestHighImpedanceModeVoltagesVdcrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring DC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. DC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltTestResultsEntry 12 }
|
|
|
|
mltTestHighImpedanceModeVoltagesVactr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring AC Voltages (Foreign
|
|
Voltages): In this mode, the DuSLIC tip and ring are in
|
|
high impedance. The measured voltages represent foreign
|
|
voltages. AC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltTestResultsEntry 13 }
|
|
|
|
mltTestHighImpedanceModeVoltagesVactg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring AC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. AC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltTestResultsEntry 14 }
|
|
|
|
mltTestHighImpedanceModeVoltagesVacrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring AC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. AC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltTestResultsEntry 15 }
|
|
|
|
mltTestDcCurrentsItransversal OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 mA"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Four DC currents will be reported: IT, IL, It and Ir.
|
|
In normal condition, currents will be measured in
|
|
active mode. These measurements will not be available if
|
|
alarm is present."
|
|
::= { mltTestResultsEntry 16 }
|
|
|
|
mltTestDcCurrentsIlongitudinal OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 mA"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Four DC currents will be reported: IT, IL, It and Ir.
|
|
In normal condition, currents will be measured in active
|
|
mode. These measurements will not be available if alarm
|
|
is present."
|
|
::= { mltTestResultsEntry 17 }
|
|
|
|
mltTestDcCurrentsItip OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 mA"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Four DC currents will be reported: IT, IL, It and Ir.
|
|
In normal condition, currents will be measured in active
|
|
mode. These measurements will not be available if alarm
|
|
is present."
|
|
::= { mltTestResultsEntry 18 }
|
|
|
|
mltTestDcCurrentsIring OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 mA"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Four DC currents will be reported: IT, IL, It and Ir.
|
|
In normal condition, currents will be measured in active
|
|
mode. These measurements will not be available if alarm
|
|
is present."
|
|
::= { mltTestResultsEntry 19 }
|
|
|
|
mltTestCapacitanceCeqtr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Capacitance measurements will support only single
|
|
element (2 terminal) circuit. In the presence of a
|
|
network of capacitance (figure 3), the individual
|
|
capacitance will not be resolved. The equivalent
|
|
capacitances CEQtr, CEQtg and CEQrg will be reported.
|
|
They represent the following:
|
|
|
|
CEQtr = Ctr + Ctg/4 + Crg/4
|
|
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
|
|
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
|
|
|
|
Capacitance measurements will not be available if fuse
|
|
test fails or alarm is present. This test is intrusive
|
|
and will be available in shutdown state only."
|
|
::= { mltTestResultsEntry 20 }
|
|
|
|
mltTestCapacitanceCeqtg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Capacitance measurements will support only single
|
|
element (2 terminal)
|
|
circuit. In the presence of a network of capacitance
|
|
(figure 3), the
|
|
individual capacitance will not be resolved. The
|
|
equivalent capacitances CEQtr, CEQtg and CEQrg will be
|
|
reported. They represent the following:
|
|
|
|
CEQtr = Ctr + Ctg/4 + Crg/4
|
|
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
|
|
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
|
|
|
|
Capacitance measurements will not be available if fuse
|
|
test fails or alarm is present. This test is intrusive
|
|
and will be available in shutdown state only."
|
|
::= { mltTestResultsEntry 21 }
|
|
|
|
mltTestCapacitanceCeqrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Capacitance measurements will support only single
|
|
element (2 terminal) circuit. In the presence of a
|
|
network of capacitance (figure 3), the individual
|
|
capacitance will not be resolved. The equivalent
|
|
capacitances CEQtr, CEQtg and CEQrg will be reported.
|
|
They represent the following:
|
|
|
|
CEQtr = Ctr + Ctg/4 + Crg/4
|
|
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
|
|
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
|
|
|
|
Capacitance measurements will not be available if fuse
|
|
test fails or alarm is present. This test is intrusive
|
|
and will be available in shutdown state only."
|
|
::= { mltTestResultsEntry 22 }
|
|
|
|
mltTestResistanceRtr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Ohm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DC resistance measurements will be based on a 3
|
|
terminal circuit model. Rtr, Rtg and Rrg will be
|
|
provided. User will have the option of specifying 3
|
|
resistance ranges: (1) low, (2) medium, (3) high. If not
|
|
specified, auto mode will be used. Resistance
|
|
measurements will not be available if fuse test fails or
|
|
alarm is present. This parameter is intrusive. This test
|
|
is intrusive and will be available in shutdown state `
|
|
only."
|
|
::= { mltTestResultsEntry 23 }
|
|
|
|
mltTestResistanceRtg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Ohm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DC resistance measurements will be based on a 3
|
|
terminal circuit model. Rtr, Rtg and Rrg will be
|
|
provided. User will have the option of specifying
|
|
3 resistance ranges: (1) low, (2) medium, (3) high. If
|
|
not specified, auto mode will be used. Resistance
|
|
measurements will not be available if fuse test fails or
|
|
alarm is present. This parameter is intrusive. This test
|
|
is intrusive and will be available in shutdown state
|
|
only."
|
|
::= { mltTestResultsEntry 24 }
|
|
|
|
mltTestResistanceRrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Ohm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DC resistance measurements will be based on a 3
|
|
terminal circuit model. Rtr, Rtg and Rrg will be
|
|
provided. User will have the option of specifying
|
|
3 resistance ranges: (1) low, (2) medium, (3) high. If
|
|
not specified, auto mode will be used. Resistance
|
|
measurements will not be available if fuse test fails or
|
|
alarm is present. This parameter is intrusive. This test
|
|
is intrusive and will be available in shutdown state
|
|
only."
|
|
::= { mltTestResultsEntry 25 }
|
|
|
|
mltTestGr909HazardousPotentialTestResult OBJECT-TYPE
|
|
SYNTAX MltTestPassFail
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test fails if the T-G or R-G ac voltage is greater
|
|
than 50 volts rms or the T-G or R-G dc voltage is
|
|
greater than 135 volts. This test will report pass/fail.
|
|
This test is intrusive and will be available in shutdown
|
|
state only."
|
|
::= { mltTestResultsEntry 26 }
|
|
|
|
mltTestGr909ForeignEmfTestResult OBJECT-TYPE
|
|
SYNTAX MltTestPassFail
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test fails if the T-G or R-G ac voltage is greater
|
|
than 50 volts rms or the T-G or R-G dc voltage is
|
|
greater than 135 volts. This test will report pass/fail.
|
|
This test is intrusive and will be available in shutdown
|
|
state only."
|
|
::= { mltTestResultsEntry 27 }
|
|
|
|
mltTestGr909FuseTestTipFuse OBJECT-TYPE
|
|
SYNTAX MltTestPassFail
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"This test determines if these fuses are blown. This
|
|
test will return pass/fail for tip and ring. This test
|
|
will not be performed if alarm is present. This
|
|
parameter is intrusive. This test is intrusive and will
|
|
be available in shutdown state only.
|
|
|
|
This object is obsolete. Object name was changed."
|
|
::= { mltTestResultsEntry 28 }
|
|
|
|
mltTestGr909FuseTestRingFuse OBJECT-TYPE
|
|
SYNTAX MltTestPassFail
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"This test determines if these fuses are blown. This
|
|
test will return pass/fail for tip and ring. This test
|
|
will not be performed if alarm is present. This
|
|
parameter is intrusive. This test is intrusive and will
|
|
be available in shutdown state only.
|
|
|
|
This object is obsolete. Object name was changed."
|
|
::= { mltTestResultsEntry 29 }
|
|
|
|
mltTestFuseTestTipFuse OBJECT-TYPE
|
|
SYNTAX MltTestPassFail
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test determines if these fuses are blown. This
|
|
test will return pass/fail for tip and ring. This test
|
|
will not be performed if alarm is present. This
|
|
parameter is intrusive. This test is intrusive and will
|
|
be available in shutdown state only."
|
|
::= { mltTestResultsEntry 38 }
|
|
|
|
mltTestFuseTestRingFuse OBJECT-TYPE
|
|
SYNTAX MltTestPassFail
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test determines if these fuses are blown. This
|
|
test will return pass/fail for tip and ring. This test
|
|
will not be performed if alarm is present. This
|
|
parameter is intrusive. This test is intrusive and will
|
|
be available in shutdown state only."
|
|
::= { mltTestResultsEntry 39 }
|
|
|
|
mltTestGr909ResistiveFaultTestResult OBJECT-TYPE
|
|
SYNTAX MltTestPassFail
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test fails if the T-R, T-G or R-G dc resistance is
|
|
less than 150k ohm. This test will not be performed if
|
|
fuse test fails or alarm is present. This test will
|
|
return pass/fail. This test is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltTestResultsEntry 30 }
|
|
|
|
mltTestGr909ReceiverOffhookTestResult OBJECT-TYPE
|
|
SYNTAX MltTestPassFail
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test fails if a non-linearity in the T-R dc
|
|
resistance of greater than 15% when measured at two
|
|
different voltage levels exists. This test will not be
|
|
performed if fuse test fails or alarm is present. This
|
|
test will return the DC resistances at two different
|
|
operating points and the percent difference between the
|
|
two DC resistances. This test is intrusive and will be
|
|
available in shutdown state only. "
|
|
::= { mltTestResultsEntry 31 }
|
|
|
|
mltTestGr909ReceiverOffhookTestResistance1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Ohm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test fails if a non-linearity in the T-R dc
|
|
resistance of greater than 15% when measured at two
|
|
different voltage levels exists. This test will not be
|
|
performed if fuse test fails or alarm is present. This
|
|
test will return the DC resistances at two different
|
|
operating points and the percent difference between the
|
|
two DC resistances. This test is intrusive and will be
|
|
available in shutdown state only. "
|
|
::= { mltTestResultsEntry 32 }
|
|
|
|
mltTestGr909ReceiverOffhookTestResistance2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Ohm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test fails if a non-linearity in the T-R dc
|
|
resistance of greater than 15% when measured at two
|
|
different voltage levels exists. This test will not be
|
|
performed if fuse test fails or alarm is present. This
|
|
test will return the DC resistances at two different
|
|
operating points and the percent difference between the
|
|
two DC resistances. This test is intrusive and will be
|
|
available in shutdown state only. "
|
|
::= { mltTestResultsEntry 33 }
|
|
|
|
mltTestGr909ReceiverOffhookTestDifference OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "%"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test fails if a non-linearity in the T-R dc
|
|
resistance of greater than 15% when measured at two
|
|
different voltage levels exists. This test will not be
|
|
performed if fuse test fails or alarm is present. This
|
|
test will return the DC resistances at two different
|
|
operating points and the percent difference between the
|
|
two DC resistances. This test is intrusive and will be
|
|
available in shutdown state only. "
|
|
::= { mltTestResultsEntry 34 }
|
|
|
|
mltTestGr909RingerTestResult OBJECT-TYPE
|
|
SYNTAX MltTestRingerResult
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test fails when the equivalent ringer count across
|
|
tip and ring is less than 0.175 REN or greater than 5
|
|
REN. This test will not run if fuse test fails or alarm
|
|
is present. This test will report passed/fail and the
|
|
REN number. This parameter is intrusive and will be
|
|
available in shutdown state shutdown only."
|
|
::= { mltTestResultsEntry 35 }
|
|
|
|
mltTestGr909RingerTestRen OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 REN"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test fails when the equivalent ringer count across
|
|
tip and ring is less than 0.175 REN or greater than 5
|
|
REN. This test will not run if fuse test fails or alarm
|
|
is present. This test will report passed/fail and the
|
|
REN number. This parameter is intrusive and will be
|
|
available in shutdown state shutdown only."
|
|
::= { mltTestResultsEntry 36 }
|
|
|
|
mltTestErrors OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates GNK and/or OTEMP alarms active when test was
|
|
run."
|
|
::= { mltTestResultsEntry 37 }
|
|
|
|
-- mlt active mode voltages results table
|
|
mltActiveModeVoltagesResultsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MltActiveModeVoltagesResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides results of the mlt active mode
|
|
voltages test.
|
|
Note that a numerical result value of -999 means that
|
|
there was an error of some sort and the value could not
|
|
be measured."
|
|
::= { mltTestResults 3 }
|
|
|
|
mltActiveModeVoltagesResultsEntry OBJECT-TYPE
|
|
SYNTAX MltActiveModeVoltagesResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry holding information about results
|
|
of mlt active mode voltages test."
|
|
INDEX { mltTestPort }
|
|
::= { mltActiveModeVoltagesResultsTable 1 }
|
|
|
|
MltActiveModeVoltagesResultsEntry ::= SEQUENCE {
|
|
mltActiveModeVoltagesVdctr Integer32,
|
|
mltActiveModeVoltagesVdctg Integer32,
|
|
mltActiveModeVoltagesVdcrg Integer32,
|
|
mltActiveModeVoltagesVactr Integer32,
|
|
mltActiveModeVoltagesVactg Integer32,
|
|
mltActiveModeVoltagesVacrg Integer32,
|
|
mltActiveModeVoltagesErrors OCTET STRING
|
|
}
|
|
|
|
mltActiveModeVoltagesVdctr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring in a
|
|
normal no shutdown state. AC voltages for T-R, T-G and
|
|
R-G will be reported.
|
|
Active mode measurements will not be available when
|
|
alarm is detected. This parameter is intrusive and will
|
|
be available in shutdown state only."
|
|
::= { mltActiveModeVoltagesResultsEntry 1 }
|
|
|
|
mltActiveModeVoltagesVdctg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring in a
|
|
normal no shutdown state. AC voltages for T-R, T-G and
|
|
R-G will be reported. Active mode measurements will not
|
|
be available when alarm is detected. This parameter is
|
|
intrusive and will be available in shutdown state only."
|
|
::= { mltActiveModeVoltagesResultsEntry 2 }
|
|
|
|
mltActiveModeVoltagesVdcrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring in a
|
|
normal no shutdown state. AC voltages for T-R, T-G and
|
|
R-G will be reported. Active mode measurements will not
|
|
be available when alarm is detected. This parameter is
|
|
intrusive and will be available in shutdown state only."
|
|
::= { mltActiveModeVoltagesResultsEntry 3 }
|
|
|
|
mltActiveModeVoltagesVactr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring in a
|
|
normal no shutdown state. Thus, VT and VR measurements
|
|
should be 0 volt. AC voltages for T-R, T-G and R-G will
|
|
be reported. Active mode measurements will not be
|
|
available when alarm is detected. This parameter is
|
|
intrusive and will be available in shutdown state only."
|
|
::= { mltActiveModeVoltagesResultsEntry 4 }
|
|
|
|
mltActiveModeVoltagesVactg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring in a
|
|
normal no shutdown state. Thus, VT and VR measurements
|
|
should be 0 volt. AC voltages for T-R, T-G and R-G will
|
|
be reported. Active mode measurements will not be
|
|
available when alarm is detected. This parameter is
|
|
intrusive and will be available in shutdown state only."
|
|
::= { mltActiveModeVoltagesResultsEntry 5 }
|
|
|
|
mltActiveModeVoltagesVacrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring in a
|
|
normal no shutdown state. Thus, VT and VR measurements
|
|
should be 0 volt. AC voltages for T-R, T-G and R-G will
|
|
be reported.
|
|
Active mode measurements will not be available when
|
|
alarm is detected. This parameter is intrusive and will
|
|
be available in shutdown state only."
|
|
|
|
::= { mltActiveModeVoltagesResultsEntry 6 }
|
|
|
|
mltActiveModeVoltagesErrors OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates GNK and/or OTEMP alarms active when test was
|
|
run."
|
|
::= { mltActiveModeVoltagesResultsEntry 7 }
|
|
|
|
-- mlt high impedance mode voltages results table
|
|
mltHighImpedanceModeVoltagesResultsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF
|
|
MltHighImpedanceModeVoltagesResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides result of the mlt test suite.
|
|
Note that a numerical result value of -999 means that
|
|
there was an error of some sort and the value could not
|
|
be measured."
|
|
::= { mltTestResults 4 }
|
|
|
|
mltHighImpedanceModeVoltagesResultsEntry OBJECT-TYPE
|
|
SYNTAX MltHighImpedanceModeVoltagesResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry holding information about results
|
|
of mlt high impedance mode voltages test."
|
|
INDEX { mltTestPort }
|
|
::= { mltHighImpedanceModeVoltagesResultsTable 1 }
|
|
|
|
MltHighImpedanceModeVoltagesResultsEntry ::= SEQUENCE {
|
|
mltHighImpedanceModeVoltagesVdctr Integer32,
|
|
mltHighImpedanceModeVoltagesVdctg Integer32,
|
|
mltHighImpedanceModeVoltagesVdcrg Integer32,
|
|
mltHighImpedanceModeVoltagesVactr Integer32,
|
|
mltHighImpedanceModeVoltagesVactg Integer32,
|
|
mltHighImpedanceModeVoltagesVacrg Integer32,
|
|
mltHighImpedanceModeVoltagesErrors OCTET STRING
|
|
}
|
|
|
|
mltHighImpedanceModeVoltagesVdctr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring DC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. DC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltHighImpedanceModeVoltagesResultsEntry 1 }
|
|
|
|
mltHighImpedanceModeVoltagesVdctg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring DC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. DC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltHighImpedanceModeVoltagesResultsEntry 2 }
|
|
|
|
mltHighImpedanceModeVoltagesVdcrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring DC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. DC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltHighImpedanceModeVoltagesResultsEntry 3 }
|
|
|
|
mltHighImpedanceModeVoltagesVactr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring AC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. AC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltHighImpedanceModeVoltagesResultsEntry 4 }
|
|
|
|
mltHighImpedanceModeVoltagesVactg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring AC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. AC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltHighImpedanceModeVoltagesResultsEntry 5 }
|
|
|
|
mltHighImpedanceModeVoltagesVacrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring AC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. AC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltHighImpedanceModeVoltagesResultsEntry 6 }
|
|
|
|
mltHighImpedanceModeVoltagesErrors OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates GNK and/or OTEMP alarms active when test was
|
|
run."
|
|
::= { mltHighImpedanceModeVoltagesResultsEntry 7 }
|
|
|
|
-- mlt DC resistance results table
|
|
mltDcResistanceResultsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MltDcResistanceResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides result of the DC resistance test.
|
|
Note that a numerical result value of -999 means that
|
|
there was an error of some sort and the value could not
|
|
be measured. Also, a resistance value of 9999 means
|
|
that the result was greater than 1000 kOhms, but the
|
|
exact value could not be measured."
|
|
::= { mltTestResults 5 }
|
|
|
|
mltDcResistanceResultsEntry OBJECT-TYPE
|
|
SYNTAX MltDcResistanceResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry holding information about results
|
|
of mlt DC resistance test."
|
|
INDEX { mltTestPort }
|
|
::= { mltDcResistanceResultsTable 1 }
|
|
|
|
MltDcResistanceResultsEntry ::= SEQUENCE {
|
|
mltDcResistanceRtr Integer32,
|
|
mltDcResistanceRtg Integer32,
|
|
mltDcResistanceRrg Integer32,
|
|
mltDcResistanceErrors OCTET STRING
|
|
}
|
|
|
|
|
|
mltDcResistanceRtr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Ohm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DC resistance measurements will be based on a 3
|
|
terminal circuit model. Rtr, Rtg and Rrg will be
|
|
provided. User will have the option of specifying
|
|
3 resistance ranges: (1) low, (2) medium, (3) high. If
|
|
not specified, auto mode will be used. Resistance
|
|
measurements will not be available if fuse test fails or
|
|
alarm is present. This parameter is intrusive. This test
|
|
is intrusive and will be available in shutdown state
|
|
only."
|
|
::= { mltDcResistanceResultsEntry 1 }
|
|
|
|
mltDcResistanceRtg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Ohm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DC resistance measurements will be based on a 3
|
|
terminal circuit model. Rtr, Rtg and Rrg will be
|
|
provided. User will have the option of specifying
|
|
3 resistance ranges: (1) low, (2) medium, (3) high. If
|
|
not specified, auto mode will be used. Resistance
|
|
measurements will not be available if fuse test fails or
|
|
alarm is present. This parameter is intrusive. This test
|
|
is intrusive and will be available in shutdown state
|
|
only."
|
|
::= { mltDcResistanceResultsEntry 2 }
|
|
|
|
mltDcResistanceRrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Ohm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DC resistance measurements will be based on a 3
|
|
terminal circuit model. Rtr, Rtg and Rrg will be
|
|
provided. User will have the option of specifying
|
|
3 resistance ranges: (1) low, (2) medium, (3) high. If
|
|
not specified, auto mode will be used. Resistance
|
|
measurements will not be available if fuse test fails or
|
|
alarm is present. This parameter is intrusive. This test
|
|
is intrusive and will be available in shutdown state
|
|
only."
|
|
::= { mltDcResistanceResultsEntry 3 }
|
|
|
|
mltDcResistanceErrors OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates GNK and/or OTEMP alarms active when test was
|
|
run."
|
|
::= { mltDcResistanceResultsEntry 4 }
|
|
|
|
-- mlt capacitance results table
|
|
mltCapacitanceResultsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MltCapacitanceResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides result of the mlt test suite.
|
|
Note that a numerical result value of -999 means that
|
|
there was an error of some sort and the value could not
|
|
be measured."
|
|
::= { mltTestResults 6 }
|
|
|
|
mltCapacitanceResultsEntry OBJECT-TYPE
|
|
SYNTAX MltCapacitanceResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry holding information about results
|
|
of mlt capacitance test."
|
|
INDEX { mltTestPort }
|
|
::= { mltCapacitanceResultsTable 1 }
|
|
|
|
MltCapacitanceResultsEntry ::= SEQUENCE {
|
|
mltCapacitanceCeqtr Integer32,
|
|
mltCapacitanceCeqtg Integer32,
|
|
mltCapacitanceCeqrg Integer32,
|
|
mltCapacitanceErrors OCTET STRING
|
|
}
|
|
|
|
mltCapacitanceCeqtr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Capacitance measurements will support only single
|
|
element (2 terminal) circuit. In the presence of a
|
|
network of capacitance (figure 3), the individual
|
|
capacitance will not be resolved. The equivalent
|
|
capacitances CEQtr, CEQtg and CEQrg will be reported.
|
|
They represent the following:
|
|
|
|
CEQtr = Ctr + Ctg/4 + Crg/4
|
|
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
|
|
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
|
|
|
|
Capacitance measurements will not be available if fuse
|
|
test fails or alarm is present. This test is intrusive
|
|
and will be available in shutdown state only."
|
|
::= { mltCapacitanceResultsEntry 1 }
|
|
|
|
mltCapacitanceCeqtg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Capacitance measurements will support only single
|
|
element (2 terminal) circuit. In the presence of a
|
|
network of capacitance (figure 3), the individual
|
|
capacitance will not be resolved. The equivalent
|
|
capacitances CEQtr, CEQtg and CEQrg will be reported.
|
|
They represent the following:
|
|
|
|
CEQtr = Ctr + Ctg/4 + Crg/4
|
|
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
|
|
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
|
|
|
|
Capacitance measurements will not be available if fuse
|
|
test fails or alarm is present. This test is intrusive
|
|
and will be available in shutdown state only."
|
|
::= { mltCapacitanceResultsEntry 2 }
|
|
|
|
mltCapacitanceCeqrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Capacitance measurements will support only single
|
|
element (2 terminal) circuit. In the presence of a
|
|
network of capacitance (figure 3), the individual
|
|
capacitance will not be resolved. The equivalent
|
|
capacitances CEQtr, CEQtg and CEQrg will be reported.
|
|
They represent the following:
|
|
|
|
CEQtr = Ctr + Ctg/4 + Crg/4
|
|
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
|
|
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
|
|
|
|
Capacitance measurements will not be available if fuse
|
|
test fails or alarm is present. This test is intrusive
|
|
and will be available in shutdown state only."
|
|
::= { mltCapacitanceResultsEntry 3 }
|
|
|
|
mltCapacitanceErrors OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates GNK and/or OTEMP alarms active when test was
|
|
run."
|
|
::= { mltCapacitanceResultsEntry 4 }
|
|
|
|
-- mlt loop detect results table
|
|
mltLoopDetectResultsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MltLoopDetectResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides result of the mlt loop detect test.
|
|
Note that a numerical result value of -999 means that
|
|
there was an error of some sort and the value could not
|
|
be measured."
|
|
::= { mltTestResults 7 }
|
|
|
|
mltLoopDetectResultsEntry OBJECT-TYPE
|
|
SYNTAX MltLoopDetectResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry holding information about results
|
|
of mlt loop detect test."
|
|
INDEX { mltTestPort }
|
|
::= { mltLoopDetectResultsTable 1 }
|
|
|
|
MltLoopDetectResultsEntry ::= SEQUENCE {
|
|
mltLoopDetectLoopCapacitance Integer32,
|
|
mltLoopDetectDetectionThreshold Integer32,
|
|
mltLoopDetectLoopDetected MltTestYesNo,
|
|
mltLoopDetectErrors OCTET STRING
|
|
}
|
|
|
|
mltLoopDetectLoopCapacitance OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop detection will be based on tip-ring capacitance
|
|
measurement. User will be able to specify the detection
|
|
threshold. If not supplied,loop detection threshold of
|
|
10 nF will be used. This test will not be available if
|
|
fuse test fails or alarm is present. This test is
|
|
intrusive and will be available in shutdown state only."
|
|
::= { mltLoopDetectResultsEntry 1 }
|
|
|
|
mltLoopDetectDetectionThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop detection will be based on tip-ring capacitance
|
|
measurement. User will be able to specify the detection
|
|
threshold. If not supplied, loop detection threshold of
|
|
10 nF will be used. This test will not be available if
|
|
fuse test fails or alarm is present. This test is
|
|
intrusive and will be available in shutdown state only."
|
|
::= { mltLoopDetectResultsEntry 2 }
|
|
|
|
mltLoopDetectLoopDetected OBJECT-TYPE
|
|
SYNTAX MltTestYesNo
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop detection will be based on tip-ring capacitance
|
|
measurement. User will be able to specify the detection
|
|
threshold. If not supplied, loop detection threshold
|
|
of 10 nF will be used. This test will not be available
|
|
if fuse test fails or alarm is present. This test is
|
|
intrusive and will be available in shutdown state only."
|
|
::= { mltLoopDetectResultsEntry 3 }
|
|
|
|
mltLoopDetectErrors OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates GNK and/or OTEMP alarms active when test
|
|
was run."
|
|
::= { mltLoopDetectResultsEntry 4 }
|
|
|
|
-- mlt loop length results table
|
|
mltLoopLengthResultsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MltLoopLengthResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides result of the mlt loop length test.
|
|
Note that a numerical result value of -999 means that
|
|
there was an error of some sort and the value could
|
|
not be measured."
|
|
::= { mltTestResults 8 }
|
|
|
|
mltLoopLengthResultsEntry OBJECT-TYPE
|
|
SYNTAX MltLoopLengthResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry holding information about results
|
|
of mlt loop length test."
|
|
INDEX { mltTestPort }
|
|
::= { mltLoopLengthResultsTable 1 }
|
|
|
|
MltLoopLengthResultsEntry ::= SEQUENCE {
|
|
mltLoopLengthCapacitanceFactor Integer32,
|
|
mltLoopLengthLoopCapacitance Integer32,
|
|
mltLoopLengthLoopLength Integer32,
|
|
mltLoopLengthUncompensatedLoopCapacitance Integer32,
|
|
mltLoopLengthUncompensatedLoopLength Integer32,
|
|
mltLoopLengthErrors OCTET STRING
|
|
}
|
|
|
|
mltLoopLengthCapacitanceFactor OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF/mile"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop length estimate will be based on tip-ring
|
|
capacitance measurement. User will be able to
|
|
specify the loop length multiplier. If not supplied,
|
|
loop length multiplier of 83 nF/ mile will be used.
|
|
This test will not be available if fuse test fails
|
|
or alarm is present. This test is intrusive and will
|
|
be available in shutdown state only."
|
|
::= { mltLoopLengthResultsEntry 1 }
|
|
|
|
mltLoopLengthLoopCapacitance OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop length estimate will be based on tip-ring
|
|
capacitance measurement. User will be able to specify
|
|
the loop length multiplier. If not supplied, loop length
|
|
multiplier of 83 nF/ mile will be used. This test will
|
|
not be available if fuse test fails or alarm is present.
|
|
This test is intrusive and will be available in shutdown
|
|
state only. "
|
|
::= { mltLoopLengthResultsEntry 2 }
|
|
|
|
mltLoopLengthLoopLength OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "ft"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop length estimate will be based on tip-ring
|
|
capacitance measurement. User will be able to specify
|
|
the loop length multiplier. If not supplied, loop length
|
|
multiplier of 83 nF/ mile will be used. This test will
|
|
not be available if fuse test fails or alarm is present.
|
|
This test is intrusive and will be available in shutdown
|
|
state only. "
|
|
::= { mltLoopLengthResultsEntry 3 }
|
|
|
|
mltLoopLengthUncompensatedLoopCapacitance OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop length estimate will be based on tip-ring
|
|
capacitance measurement. User will be able to specify
|
|
the loop length multiplier. If not supplied, loop length
|
|
multiplier of 83 nF/ mile will be used. This test will
|
|
not be available if fuse test fails or alarm is present.
|
|
This test is intrusive and will be available in shutdown
|
|
state only. This value has no DSL correction."
|
|
::= { mltLoopLengthResultsEntry 4 }
|
|
|
|
mltLoopLengthUncompensatedLoopLength OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "ft"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop length estimate will be based on tip-ring
|
|
capacitance measurement. User will be able to specify
|
|
the loop length multiplier. If not supplied, loop length
|
|
multiplier of 83 nF/ mile will be used. This test will
|
|
not be available if fuse test fails or alarm is present.
|
|
This test is intrusive and will be available in shutdown
|
|
state only. This value has no DSL correction."
|
|
::= { mltLoopLengthResultsEntry 5 }
|
|
|
|
|
|
mltLoopLengthErrors OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates GNK and/or OTEMP alarms active when test was
|
|
run."
|
|
::= { mltLoopLengthResultsEntry 6 }
|
|
|
|
-- notifications
|
|
|
|
mltTestCompletedNotification NOTIFICATION-TYPE
|
|
OBJECTS { mltTestIdentifier, mltTestPort,
|
|
mltLastTestStatus, mltErrorText }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent to the
|
|
requesting host when the requested mlt
|
|
test has completed."
|
|
::= { mltTestNotifications 1 }
|
|
|
|
|
|
|
|
END
|