mibs/MIBS/cdata/NSCRTV-HFCEMS-OPTICALAMPLIFIER-MIB

442 lines
9.9 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
NSCRTV-HFCEMS-OPTICALAMPLIFIER-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM RFC1213-MIB
oaIdent
FROM NSCRTV-ROOT
;
oaVendorOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS optional
DESCRIPTION ""
::= { oaIdent 1 }
oaOutputOpticalPower OBJECT-TYPE
SYNTAX INTEGER ( 0..65535 )
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { oaIdent 2 }
oaInputOpticalPower OBJECT-TYPE
SYNTAX INTEGER ( -128..127 )
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { oaIdent 3 }
oaPumpTable OBJECT-TYPE
SYNTAX SEQUENCE OF OaPumpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
::= { oaIdent 4 }
oaPumpEntry OBJECT-TYPE
SYNTAX OaPumpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { oaPumpIndex }
::= { oaPumpTable 1 }
OaPumpEntry ::=
SEQUENCE
{
oaPumpIndex
INTEGER,
oaPumpBIAS
INTEGER,
oaPumpTEC
INTEGER,
oaPumpTemp
INTEGER
}
oaPumpIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { oaPumpEntry 1 }
oaPumpBIAS OBJECT-TYPE
SYNTAX INTEGER ( 0..65535 )
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { oaPumpEntry 2 }
oaPumpTEC OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
ACCESS read-only
STATUS optional
DESCRIPTION ""
::= { oaPumpEntry 3 }
oaPumpTemp OBJECT-TYPE
SYNTAX INTEGER ( 0..32768 )
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { oaPumpEntry 4 }
oaNumberDCPowerSupply OBJECT-TYPE
SYNTAX INTEGER ( 0..16 )
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { oaIdent 5 }
oaDCPowerSupplyMode OBJECT-TYPE
SYNTAX INTEGER { loadsharing(1), switchedRedundant(2),aloneSupply(3) }
ACCESS read-only
STATUS optional
DESCRIPTION " "
::= { oaIdent 6 }
oaDCPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF OaDCPowerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
::= { oaIdent 7 }
oaDCPowerEntry OBJECT-TYPE
SYNTAX OaDCPowerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { oaDCPowerIndex }
::= { oaDCPowerTable 1 }
OaDCPowerEntry ::=
SEQUENCE
{
oaDCPowerIndex
INTEGER,
oaDCPowerVoltage
INTEGER,
oaDCPowerCurrent
INTEGER,
oaDCPowerName
DisplayString
}
oaDCPowerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { oaDCPowerEntry 1 }
oaDCPowerVoltage OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { oaDCPowerEntry 2 }
oaDCPowerCurrent OBJECT-TYPE
SYNTAX INTEGER ( 0..65535 )
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { oaDCPowerEntry 3 }
oaDCPowerName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { oaDCPowerEntry 4 }
oaVendorExtend OBJECT IDENTIFIER ::= { oaIdent 8 }
AdminEDFAIP OBJECT IDENTIFIER ::= { oaVendorExtend 13 }
edfaIPNetTabNum OBJECT IDENTIFIER ::= { AdminEDFAIP 1 }
edfaIPTable OBJECT IDENTIFIER ::= { AdminEDFAIP 2 }
oaPumpNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION ""
::= { oaVendorExtend 1 }
oaOutputPowerSet OBJECT-TYPE
SYNTAX INTEGER ( 0..4000 )
ACCESS read-write
STATUS optional
DESCRIPTION ""
::= { oaVendorExtend 2 }
oaOutputPowerSetValueMax OBJECT-TYPE
SYNTAX INTEGER ( 0..4000 )
ACCESS read-only
STATUS optional
DESCRIPTION ""
::= { oaVendorExtend 3 }
oaOutputPowerSetValueMin OBJECT-TYPE
SYNTAX INTEGER ( 0..4000 )
ACCESS read-only
STATUS optional
DESCRIPTION ""
::= { oaVendorExtend 4 }
oaFansState OBJECT-TYPE
SYNTAX INTEGER { on(1), off(2)}
ACCESS read-only
STATUS optional
DESCRIPTION ""
::= { oaVendorExtend 5 }
oaFansControl OBJECT-TYPE
SYNTAX INTEGER { on(1), off(2), auto(3) }
ACCESS read-write
STATUS optional
DESCRIPTION ""
::= { oaVendorExtend 6 }
oaInputOpticalPower2 OBJECT-TYPE
SYNTAX INTEGER ( -2000..2000 )
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { oaVendorExtend 7 }
oaOpticalOutputNum OBJECT-TYPE
SYNTAX INTEGER ( -128..127 )
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { oaVendorExtend 8 }
oaABControl OBJECT-TYPE
SYNTAX INTEGER { Auto(1), M(2)}
ACCESS read-only
STATUS optional
DESCRIPTION ""
::= { oaVendorExtend 9 }
oaDSControl OBJECT-TYPE
SYNTAX INTEGER { CH(1), CH(2)}
ACCESS read-only
STATUS optional
DESCRIPTION ""
::= { oaVendorExtend 10 }
oaABState OBJECT-TYPE
SYNTAX INTEGER { CH(1), CH(2)}
ACCESS read-only
STATUS optional
DESCRIPTION ""
::= { oaVendorExtend 11 }
oaEDFAAlarmRangeTable OBJECT-TYPE
SYNTAX SEQUENCE OF OaEDFAAlarmRangeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { oaVendorExtend 12 }
oaEDFAAlarmRangeEntry OBJECT-TYPE
SYNTAX OaEDFAAlarmRangeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { oaEDFAAlarmRangeIndex }
::= { oaEDFAAlarmRangeTable 1 }
OaEDFAAlarmRangeEntry ::=
SEQUENCE {
oaEDFAAlarmRangeIndex
INTEGER,
oaEDFAAlarmRangeDecr
OCTET STRING,
oaEDFAAlarmRangeHIHItoHI
INTEGER,
oaEDFAAlarmRangeHIHItoLO
INTEGER,
oaEDFAAlarmRangeHItoHI
INTEGER,
oaEDFAAlarmRangeHItoLO
INTEGER,
oaEDFAAlarmRangeLOtoHI
INTEGER,
oaEDFAAlarmRangeLOtoLO
INTEGER,
oaEDFAAlarmRangeLOLOtoHI
INTEGER,
oaEDFAAlarmRangeLOLOtoLO
INTEGER,
oaEDFAAlarmRangeDDtoHI
INTEGER,
oaEDFAAlarmRangeDDtoLO
INTEGER
}
oaEDFAAlarmRangeIndex OBJECT-TYPE
SYNTAX INTEGER (1..12)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 1 }
oaEDFAAlarmRangeDecr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 2 }
oaEDFAAlarmRangeHIHItoHI OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 3 }
oaEDFAAlarmRangeHIHItoLO OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 4 }
oaEDFAAlarmRangeHItoHI OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 5 }
oaEDFAAlarmRangeHItoLO OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 6 }
oaEDFAAlarmRangeLOtoHI OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 7 }
oaEDFAAlarmRangeLOtoLO OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 8 }
oaEDFAAlarmRangeLOLOtoHI OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 9 }
oaEDFAAlarmRangeLOLOtoLO OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 10 }
oaEDFAAlarmRangeDDtoHI OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 11 }
oaEDFAAlarmRangeDDtoLO OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 12 }
edfaIPNetTabNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { AdminEDFAIP 1 }
edfaIPTable OBJECT-TYPE
SYNTAX SEQUENCE OF EdfaNetIPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
::= { AdminEDFAIP 2 }
EdfaNetIPEntry OBJECT-TYPE
SYNTAX EdfaNetIPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { MachineNetIpIndex }
::= { edfaIPTable 1 }
EdfaNetIPEntry ::=
SEQUENCE
{
MachineNetIpIndex
INTEGER,
MachineNetIpDecr
DisplayString,
MachineNetIpMessg
IpAddress
}
MachineNetIpIndex OBJECT-TYPE
SYNTAX INTEGER ( 0..10 )
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { EdfaNetIPEntry 1 }
MachineNetIpDecr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { EdfaNetIPEntry 2 }
MachineNetIpMessg OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION ""
::= { EdfaNetIPEntry 3 }
END