442 lines
9.9 KiB
Plaintext
442 lines
9.9 KiB
Plaintext
NSCRTV-HFCEMS-OPTICALAMPLIFIER-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
DisplayString
|
|
FROM RFC1213-MIB
|
|
oaIdent
|
|
FROM NSCRTV-ROOT
|
|
;
|
|
|
|
oaVendorOID OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION ""
|
|
::= { oaIdent 1 }
|
|
|
|
|
|
oaOutputOpticalPower OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0..65535 )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaIdent 2 }
|
|
|
|
oaInputOpticalPower OBJECT-TYPE
|
|
SYNTAX INTEGER ( -128..127 )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaIdent 3 }
|
|
|
|
oaPumpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OaPumpEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaIdent 4 }
|
|
|
|
oaPumpEntry OBJECT-TYPE
|
|
SYNTAX OaPumpEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX { oaPumpIndex }
|
|
::= { oaPumpTable 1 }
|
|
|
|
OaPumpEntry ::=
|
|
SEQUENCE
|
|
{
|
|
oaPumpIndex
|
|
INTEGER,
|
|
oaPumpBIAS
|
|
INTEGER,
|
|
oaPumpTEC
|
|
INTEGER,
|
|
oaPumpTemp
|
|
INTEGER
|
|
}
|
|
|
|
oaPumpIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaPumpEntry 1 }
|
|
|
|
oaPumpBIAS OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0..65535 )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaPumpEntry 2 }
|
|
|
|
oaPumpTEC OBJECT-TYPE
|
|
SYNTAX INTEGER ( -32768..32767 )
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION ""
|
|
::= { oaPumpEntry 3 }
|
|
|
|
oaPumpTemp OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0..32768 )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaPumpEntry 4 }
|
|
|
|
|
|
oaNumberDCPowerSupply OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0..16 )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaIdent 5 }
|
|
|
|
oaDCPowerSupplyMode OBJECT-TYPE
|
|
SYNTAX INTEGER { loadsharing(1), switchedRedundant(2),aloneSupply(3) }
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION " "
|
|
::= { oaIdent 6 }
|
|
|
|
oaDCPowerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OaDCPowerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaIdent 7 }
|
|
|
|
oaDCPowerEntry OBJECT-TYPE
|
|
SYNTAX OaDCPowerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX { oaDCPowerIndex }
|
|
::= { oaDCPowerTable 1 }
|
|
|
|
OaDCPowerEntry ::=
|
|
SEQUENCE
|
|
{
|
|
oaDCPowerIndex
|
|
INTEGER,
|
|
oaDCPowerVoltage
|
|
INTEGER,
|
|
oaDCPowerCurrent
|
|
INTEGER,
|
|
oaDCPowerName
|
|
DisplayString
|
|
}
|
|
|
|
oaDCPowerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaDCPowerEntry 1 }
|
|
|
|
oaDCPowerVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER ( -32768..32767 )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaDCPowerEntry 2 }
|
|
|
|
oaDCPowerCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0..65535 )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaDCPowerEntry 3 }
|
|
|
|
oaDCPowerName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaDCPowerEntry 4 }
|
|
|
|
oaVendorExtend OBJECT IDENTIFIER ::= { oaIdent 8 }
|
|
|
|
AdminEDFAIP OBJECT IDENTIFIER ::= { oaVendorExtend 13 }
|
|
|
|
edfaIPNetTabNum OBJECT IDENTIFIER ::= { AdminEDFAIP 1 }
|
|
edfaIPTable OBJECT IDENTIFIER ::= { AdminEDFAIP 2 }
|
|
|
|
|
|
oaPumpNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION ""
|
|
::= { oaVendorExtend 1 }
|
|
|
|
oaOutputPowerSet OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0..4000 )
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION ""
|
|
::= { oaVendorExtend 2 }
|
|
|
|
oaOutputPowerSetValueMax OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0..4000 )
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION ""
|
|
::= { oaVendorExtend 3 }
|
|
|
|
oaOutputPowerSetValueMin OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0..4000 )
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION ""
|
|
::= { oaVendorExtend 4 }
|
|
|
|
oaFansState OBJECT-TYPE
|
|
SYNTAX INTEGER { on(1), off(2)}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION ""
|
|
::= { oaVendorExtend 5 }
|
|
|
|
oaFansControl OBJECT-TYPE
|
|
SYNTAX INTEGER { on(1), off(2), auto(3) }
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION ""
|
|
::= { oaVendorExtend 6 }
|
|
|
|
oaInputOpticalPower2 OBJECT-TYPE
|
|
SYNTAX INTEGER ( -2000..2000 )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaVendorExtend 7 }
|
|
|
|
oaOpticalOutputNum OBJECT-TYPE
|
|
SYNTAX INTEGER ( -128..127 )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaVendorExtend 8 }
|
|
|
|
oaABControl OBJECT-TYPE
|
|
SYNTAX INTEGER { Auto(1), M(2)}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION ""
|
|
::= { oaVendorExtend 9 }
|
|
|
|
oaDSControl OBJECT-TYPE
|
|
SYNTAX INTEGER { CH(1), CH(2)}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION ""
|
|
::= { oaVendorExtend 10 }
|
|
|
|
oaABState OBJECT-TYPE
|
|
SYNTAX INTEGER { CH(1), CH(2)}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION ""
|
|
::= { oaVendorExtend 11 }
|
|
|
|
oaEDFAAlarmRangeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OaEDFAAlarmRangeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { oaVendorExtend 12 }
|
|
|
|
oaEDFAAlarmRangeEntry OBJECT-TYPE
|
|
SYNTAX OaEDFAAlarmRangeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description."
|
|
INDEX { oaEDFAAlarmRangeIndex }
|
|
::= { oaEDFAAlarmRangeTable 1 }
|
|
|
|
|
|
OaEDFAAlarmRangeEntry ::=
|
|
SEQUENCE {
|
|
oaEDFAAlarmRangeIndex
|
|
INTEGER,
|
|
oaEDFAAlarmRangeDecr
|
|
OCTET STRING,
|
|
oaEDFAAlarmRangeHIHItoHI
|
|
INTEGER,
|
|
oaEDFAAlarmRangeHIHItoLO
|
|
INTEGER,
|
|
oaEDFAAlarmRangeHItoHI
|
|
INTEGER,
|
|
oaEDFAAlarmRangeHItoLO
|
|
INTEGER,
|
|
oaEDFAAlarmRangeLOtoHI
|
|
INTEGER,
|
|
oaEDFAAlarmRangeLOtoLO
|
|
INTEGER,
|
|
oaEDFAAlarmRangeLOLOtoHI
|
|
INTEGER,
|
|
oaEDFAAlarmRangeLOLOtoLO
|
|
INTEGER,
|
|
oaEDFAAlarmRangeDDtoHI
|
|
INTEGER,
|
|
oaEDFAAlarmRangeDDtoLO
|
|
INTEGER
|
|
}
|
|
|
|
oaEDFAAlarmRangeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description."
|
|
::= { oaEDFAAlarmRangeEntry 1 }
|
|
|
|
oaEDFAAlarmRangeDecr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description."
|
|
::= { oaEDFAAlarmRangeEntry 2 }
|
|
|
|
oaEDFAAlarmRangeHIHItoHI OBJECT-TYPE
|
|
SYNTAX INTEGER ( -32768..32767 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description."
|
|
::= { oaEDFAAlarmRangeEntry 3 }
|
|
|
|
oaEDFAAlarmRangeHIHItoLO OBJECT-TYPE
|
|
SYNTAX INTEGER ( -32768..32767 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description."
|
|
::= { oaEDFAAlarmRangeEntry 4 }
|
|
|
|
oaEDFAAlarmRangeHItoHI OBJECT-TYPE
|
|
SYNTAX INTEGER ( -32768..32767 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description."
|
|
::= { oaEDFAAlarmRangeEntry 5 }
|
|
|
|
oaEDFAAlarmRangeHItoLO OBJECT-TYPE
|
|
SYNTAX INTEGER ( -32768..32767 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description."
|
|
::= { oaEDFAAlarmRangeEntry 6 }
|
|
|
|
oaEDFAAlarmRangeLOtoHI OBJECT-TYPE
|
|
SYNTAX INTEGER ( -32768..32767 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description."
|
|
::= { oaEDFAAlarmRangeEntry 7 }
|
|
|
|
oaEDFAAlarmRangeLOtoLO OBJECT-TYPE
|
|
SYNTAX INTEGER ( -32768..32767 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description."
|
|
::= { oaEDFAAlarmRangeEntry 8 }
|
|
|
|
oaEDFAAlarmRangeLOLOtoHI OBJECT-TYPE
|
|
SYNTAX INTEGER ( -32768..32767 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description."
|
|
::= { oaEDFAAlarmRangeEntry 9 }
|
|
|
|
oaEDFAAlarmRangeLOLOtoLO OBJECT-TYPE
|
|
SYNTAX INTEGER ( -32768..32767 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description."
|
|
::= { oaEDFAAlarmRangeEntry 10 }
|
|
|
|
oaEDFAAlarmRangeDDtoHI OBJECT-TYPE
|
|
SYNTAX INTEGER ( -32768..32767 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description."
|
|
::= { oaEDFAAlarmRangeEntry 11 }
|
|
|
|
oaEDFAAlarmRangeDDtoLO OBJECT-TYPE
|
|
SYNTAX INTEGER ( -32768..32767 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description."
|
|
::= { oaEDFAAlarmRangeEntry 12 }
|
|
|
|
edfaIPNetTabNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { AdminEDFAIP 1 }
|
|
|
|
edfaIPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EdfaNetIPEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { AdminEDFAIP 2 }
|
|
|
|
EdfaNetIPEntry OBJECT-TYPE
|
|
SYNTAX EdfaNetIPEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX { MachineNetIpIndex }
|
|
::= { edfaIPTable 1 }
|
|
|
|
EdfaNetIPEntry ::=
|
|
SEQUENCE
|
|
{
|
|
MachineNetIpIndex
|
|
INTEGER,
|
|
MachineNetIpDecr
|
|
DisplayString,
|
|
MachineNetIpMessg
|
|
IpAddress
|
|
}
|
|
|
|
MachineNetIpIndex OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0..10 )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { EdfaNetIPEntry 1 }
|
|
|
|
MachineNetIpDecr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { EdfaNetIPEntry 2 }
|
|
|
|
MachineNetIpMessg OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { EdfaNetIPEntry 3 }
|
|
|
|
|
|
END |