-- CERENT-OPTICAL-MONITOR-MIB.mib
--
-- Copyright (c) 2002 by Cisco Systems, Inc.
-- All rights reserved.
-- *****************************************************************
CERENT-OPTICAL-MONITOR-MIB DEFINITIONS ::= BEGIN
IMPORTS
Integer32,
MODULE-IDENTITY,
OBJECT-TYPE FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
TruthValue FROM SNMPv2-TC
MODULE-COMPLIANCE,
OBJECT-GROUP FROM SNMPv2-CONF
ifIndex FROM IF-MIB
cerentModules,
cerentRequirements,
cerentGeneric FROM CERENT-GLOBAL-REGISTRY
CerentPeriod FROM CERENT-TC
;
cerentOpticalMonitorMIB MODULE-IDENTITY
LAST-UPDATED "0211110000Z" -- 2002/Nov/11
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO "support@Cisco.com
Postal:
Cisco Systems
1450 N. McDowell Blvd.
Petaluma, CA 94954
Tel: +1-877-323-7368"
DESCRIPTION
"This MIB module defines objects to monitor optical
characteristics and set corresponding thresholds, on the
optical interfaces in a network element.
This module is an adaptation of CISCO-OPTICAL-MONITOR-MIB.
"
REVISION "0211110000Z" -- 2002/Nov/11
DESCRIPTION
"The initial revision of this MIB."
::={ cerentModules 70 }
-- Textual Conventions
OpticalParameterType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This value indicates the optical parameter that is
being monitored. Valid values are -
power (1) : Optical Power (AC + DC).
acPower (2) : Optical AC Power.
apdTemp (3) : Avalanche Photo Detector Temperature.
laserTemp (4) : Laser Temperature.
biasCurrent (5) : Laser bias current.
peltierCurrent (6) : Laser peltier current.
xcvrVoltage (7) : Transceiver voltage.
voa (8) : Variable Optical Attenuation Failure & Degrade Th.
gain (9) : Optical amplifier gain Failure & Degrade Th.
oscPower (10) : OSC Optical Power
addPower (11) : Add Optical Power
"
SYNTAX INTEGER {
power(1),
acPower(2),
apdTemp(3),
laserTemp(4),
biasCurrent(5),
peltierCurrent(6),
xcvrVoltage(7),
voa(8),
gain(9),
oscPower(10),
addPower(11)
}
OpticalParameterValue ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The value of the optical parameter that is being monitored.
The range of values varies depending on the type of optical
parameter being monitored, as identified by a corresponding
object with syntax OpticalParameterType.
when the optical parameter being monitored is 'power' or
'acpower', the supported range is from -1000 to 1000, in
1/10ths of dBm.
Example: Actual power of -40 dbm is represented as -400.
Actual power level of +30 dBm is represented as 300.
When the optical parameter being monitored is 'laserTemp' or
'apdTemp', the supported range is from -10000 to 30000, in
1/100ths of degrees centigrade.
Example: A value of 2355 represents a temperature reading of
23.55 degrees C.
When the optical parameter being monitored is 'biasCurrent',
the supported range is from 0 to 1000, in 1/10ths of
percentage (%).
Example: A value of 500 represents a bias current threshold
of 50.0 %.
When the optical parameter being monitored is 'peltierCurrent',
the supported range is from 0 to 10000, in milliamperes.
When the optical parameter being monitored is 'xcvrVoltage',
the supported range is from 0 to 100000, in 1/10ths of
millivolts.
Example: A Value of 115 represents a transceiver voltage
reading of 11.5 millivolts.
The distinguished value of '-1000000' indicates that the object
has not yet been initialized or does not apply.
"
SYNTAX Integer32 ( -1000000..1000000 )
OpticalIfDirection ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This value indicates the direction being monitored at
the optical interface.
"
SYNTAX INTEGER {
receive(1),
transmit(2),
notApplicable(3)
}
-- MIB Object Definitions
cerentOpticalMonitorMIBObjects OBJECT IDENTIFIER ::=
{cerentGeneric 30 }
-- groups in this MIB module
cerentOpticalMonGroup OBJECT IDENTIFIER ::=
{cerentOpticalMonitorMIBObjects 1 }
cerentOpticalPMGroup OBJECT IDENTIFIER ::=
{cerentOpticalMonitorMIBObjects 2 }
-- cOpticalMonTable
cOpticalMonTable OBJECT-TYPE
SYNTAX SEQUENCE OF COpticalMonEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides objects to monitor optical
parameters in a network element. It also provides
objects for setting high and low threshold levels, with
configurable severities, on these monitored parameters."
::={ cerentOpticalMonGroup 1 }
cOpticalMonEntry OBJECT-TYPE
SYNTAX COpticalMonEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the cOpticalMonTable provides objects to
monitor an optical parameter and set threshold levels
on that parameter, at an optical interface.
Note that the set of monitored optical parameters may vary
based on interface type and direction.
Examples of interfaces that can have an entry in this table
include optical transceivers optical amplifiers,
and optical attenuators."
INDEX { ifIndex, cOpticalMonDirection,
cOpticalMonParameterType }
::={ cOpticalMonTable 1 }
COpticalMonEntry ::= SEQUENCE {
cOpticalMonDirection OpticalIfDirection,
cOpticalMonParameterType OpticalParameterType,
cOpticalParameterValue OpticalParameterValue,
cOpticalParamHighAlarmThresh OpticalParameterValue,
cOpticalParamHighWarning15MinThresh OpticalParameterValue,
cOpticalParamHighWarning1DayThresh OpticalParameterValue,
cOpticalParamLowAlarmThresh OpticalParameterValue,
cOpticalParamLowWarning15MinThresh OpticalParameterValue,
cOpticalParamLowWarning1DayThresh OpticalParameterValue,
cOpticalParamLowDegradeThresh OpticalParameterValue,
cOpticalParamHighDegradeThresh OpticalParameterValue
}
cOpticalMonDirection OBJECT-TYPE
SYNTAX OpticalIfDirection
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is an index into the cOpticalMonTable
and indicates the direction monitored for the
optical interface, in this entry."
::={ cOpticalMonEntry 1 }
cOpticalMonParameterType OBJECT-TYPE
SYNTAX OpticalParameterType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is an index into the cOpticalMonTable
and specifies the optical parameter that is being monitored,
in this entry."
::={ cOpticalMonEntry 2 }
cOpticalParameterValue OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the value measured for the particular
optical parameter specified by the cOpticalMonParameterType
object."
::={ cOpticalMonEntry 3 }
cOpticalParamHighAlarmThresh OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to set a high alarm threshold on the
optical parameter being monitored.
If the measured value of the parameter,is greater than the
value configured in this object, an alarm will be raised.
When the cOpticalMonParameterType object is set to 'power'
for the receive direction at a transceiver, this object
specifies the receiver saturation level."
::={ cOpticalMonEntry 4 }
cOpticalParamHighWarning15MinThresh OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to set a high warning 15 minute threshold
on the optical parameter being monitored.
If the measured value of the parameter,is greater than the
value configured in this object, an alarm may be raised."
::={ cOpticalMonEntry 5 }
cOpticalParamHighWarning1DayThresh OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to set a high warning 1 day threshold on
the optical parameter being monitored.
If the measured value of the parameter,is greater than the
value configured in this object, an alarm may be raised."
::={ cOpticalMonEntry 6 }
cOpticalParamLowAlarmThresh OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to set a low alarm threshold on the
optical parameter being monitored.
If the measured value of the parameter,goes lower than the
value configured in this object, an alarm will be raised.
When the cOpticalMonParameterType object is set to 'power'
for the receive direction and when the interface supports
alarms based on loss of light, this object specifies the
optical power threshold for declaring loss of light. Also,
when optical amplifiers are present in the network, in the
receive direction, this value may need to be configured,
since the noise floor may be higher than the minimum
sensitivity of the receiver."
::={ cOpticalMonEntry 7 }
cOpticalParamLowWarning15MinThresh OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to set a low warning 15 minute threshold
on the optical parameter being monitored.
If the measured value of the parameter,goes lower than the
value configured in this object, an alarm will be raised."
::={ cOpticalMonEntry 8 }
cOpticalParamLowWarning1DayThresh OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to set a low warning 1 day threshold
on the optical parameter being monitored.
If the measured value of the parameter,goes lower than the
value configured in this object, an alarm will be raised."
::={ cOpticalMonEntry 9 }
cOpticalParamLowDegradeThresh OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to set a low degrade threshold
on the optical parameter being monitored.
If the measured value of the parameter,goes lower than the
value configured in this object, a degrade alarm will be raised."
::={ cOpticalMonEntry 10 }
cOpticalParamHighDegradeThresh OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to set a high degrade threshold
on the optical parameter being monitored.
If the measured value of the parameter,goes lower than the
value configured in this object, a degrade alarm will be raised."
::={ cOpticalMonEntry 11 }
-- cOpticalPMCurrent Table
cOpticalPMCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF COpticalPMCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table stores performance monitoring data for the
various optical parameters, collected over the current
interval."
::={ cerentOpticalPMGroup 1 }
cOpticalPMCurrentEntry OBJECT-TYPE
SYNTAX COpticalPMCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the cOpticalPMCurrentTable. It contains
performance monitoring data for an optical parameter,
collected over the current interval.
Note that the set of monitored optical parameters may vary
based on interface type and direction.
Examples of interfaces that can have an entry in this table
include optical transceivers, optical amplifiers, and optical
attenuators."
INDEX { ifIndex,
cOpticalPMCurrentDirection,
cOpticalPMCurrentParamType,
cOpticalPMCurrentPeriod}
::={ cOpticalPMCurrentTable 1 }
COpticalPMCurrentEntry ::= SEQUENCE {
cOpticalPMCurrentDirection OpticalIfDirection,
cOpticalPMCurrentParamType OpticalParameterType,
cOpticalPMCurrentPeriod CerentPeriod,
cOpticalPMCurrentMaxParam OpticalParameterValue,
cOpticalPMCurrentMinParam OpticalParameterValue,
cOpticalPMCurrentMeanParam OpticalParameterValue
}
cOpticalPMCurrentDirection OBJECT-TYPE
SYNTAX OpticalIfDirection
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is an index into the cOpticalPMCurrentTable
and indicates the direction monitored
for the optical interface, in this entry."
::={ cOpticalPMCurrentEntry 1 }
cOpticalPMCurrentParamType OBJECT-TYPE
SYNTAX OpticalParameterType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is an index into the
cOpticalPMCurrentTable and specifies the optical parameter
that is being monitored, in this entry."
::={ cOpticalPMCurrentEntry 2 }
cOpticalPMCurrentPeriod OBJECT-TYPE
SYNTAX CerentPeriod
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is an index into the
cOpticalPMCurrentTable and indicates whether the
optical parameter values given in this entry, are collected
over a period of 15 minutes or 24 hours."
::={ cOpticalPMCurrentEntry 3 }
cOpticalPMCurrentMaxParam OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the maximum value measured for the optical
parameter, in the current 15 minute or 24 hour interval."
::={ cOpticalPMCurrentEntry 4 }
cOpticalPMCurrentMinParam OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the minimum value measured for the optical
parameter, in the current 15 minute or 24 hour interval."
::={ cOpticalPMCurrentEntry 5 }
cOpticalPMCurrentMeanParam OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the average value of the measured optical
parameter, in the current 15 minute or 24 hour interval."
::={ cOpticalPMCurrentEntry 6 }
-- cOpticalPMInterval Table
cOpticalPMIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF COpticalPMIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table stores performance monitoring data for the
various optical parameters, collected over current and
previous intervals.
This table can have entries for up to 96 complete 15 minute
intervals."
::={ cerentOpticalPMGroup 2 }
cOpticalPMIntervalEntry OBJECT-TYPE
SYNTAX COpticalPMIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the cOpticalPMIntervalTable. It contains
performance monitoring data for an optical parameter,
collected over current and previous intervals.
Note that the set of monitored optical parameters may vary
based on interface type and direction.
Examples of interfaces that can have an entry in this table
include optical transceivers, optical amplifiers, and optical
attenuators."
INDEX { ifIndex,
cOpticalPMIntervalDirection,
cOpticalPMIntervalParamType,
cOpticalPMIntervalPeriod,
cOpticalPMIntervalNumber}
::={ cOpticalPMIntervalTable 1 }
COpticalPMIntervalEntry ::= SEQUENCE {
cOpticalPMIntervalDirection OpticalIfDirection,
cOpticalPMIntervalParamType OpticalParameterType,
cOpticalPMIntervalPeriod CerentPeriod,
cOpticalPMIntervalNumber Integer32,
cOpticalPMIntervalMaxParam OpticalParameterValue,
cOpticalPMIntervalMinParam OpticalParameterValue,
cOpticalPMIntervalMeanParam OpticalParameterValue,
cOpticalPMIntervalValidData TruthValue
}
cOpticalPMIntervalDirection OBJECT-TYPE
SYNTAX OpticalIfDirection
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is an index into the cOpticalPMIntervalTable
and indicates the direction monitored
for the optical interface, in this entry."
::={ cOpticalPMIntervalEntry 1 }
cOpticalPMIntervalParamType OBJECT-TYPE
SYNTAX OpticalParameterType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is an index into the
cOpticalPMIntervalTable and specifies the optical parameter
that is being monitored, in this entry."
::={ cOpticalPMIntervalEntry 2 }
cOpticalPMIntervalPeriod OBJECT-TYPE
SYNTAX CerentPeriod
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is an index into the
cOpticalPMIntervalTable and indicates whether the
optical parameter values given in this entry, are collected
over a period of 15 minutes or 24 hours."
::={ cOpticalPMIntervalEntry 3 }
cOpticalPMIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is an index into the cOpticalPMIntervalTable.
It is a number between 1 and 96, which identifies the
interval for which the set of optical parameter values is
available. The interval identified by 1 is the most recent
15 minute or 24 hour interval, and the interval
identified by N is the interval immediately preceding the one
identified by N-1."
::={ cOpticalPMIntervalEntry 4 }
cOpticalPMIntervalMaxParam OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the maximum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval."
::={ cOpticalPMIntervalEntry 5 }
cOpticalPMIntervalMinParam OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the minimum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval."
::={ cOpticalPMIntervalEntry 6 }
cOpticalPMIntervalMeanParam OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the average value of the measured optical
parameter, in a particular 15 minute or 24 hour interval."
::={ cOpticalPMIntervalEntry 7 }
cOpticalPMIntervalValidData OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates if the data for this
interval is valid."
::= { cOpticalPMIntervalEntry 8 }
-- MIB Conformance Statements
cerentOpticalMonitorMIBConformance OBJECT IDENTIFIER ::=
{ cerentRequirements 20 }
cerentOpticalMonitorMIBCompliances OBJECT IDENTIFIER ::=
{ cerentOpticalMonitorMIBConformance 1 }
cerentOpticalMonitorMIBGroups OBJECT IDENTIFIER ::=
{ cerentOpticalMonitorMIBConformance 2 }
cerentOpticalMonitorMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for network elements that
monitor optical characteristics and set thresholds on the
optical interfaces in a network element."
MODULE -- this module
MANDATORY-GROUPS { cerentOpticalMIBMonGroup }
GROUP cerentOpticalMIBThresholdGroup
DESCRIPTION
"This group is required for network elements that support
thresholds on optical parameters."
GROUP cerentOpticalMIBPMGroup
DESCRIPTION
"This group is required for network elements that
support collection of optical performance monitoring
data for 15 minute or 24 hour intervals."
OBJECT cOpticalParamHighAlarmThresh
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cOpticalParamHighWarning15MinThresh
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cOpticalParamHighWarning1DayThresh
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cOpticalParamLowAlarmThresh
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cOpticalParamLowWarning15MinThresh
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT cOpticalParamLowWarning1DayThresh
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::={ cerentOpticalMonitorMIBCompliances 1 }
-- Units of Conformance
cerentOpticalMIBMonGroup OBJECT-GROUP
OBJECTS {
cOpticalParameterValue
}
STATUS current
DESCRIPTION
"A mandatory object that provides monitoring of optical
characteristics."
::={ cerentOpticalMonitorMIBGroups 1 }
cerentOpticalMIBThresholdGroup OBJECT-GROUP
OBJECTS {
cOpticalParamHighAlarmThresh,
cOpticalParamHighWarning15MinThresh,
cOpticalParamHighWarning1DayThresh,
cOpticalParamLowAlarmThresh,
cOpticalParamLowWarning15MinThresh,
cOpticalParamLowWarning1DayThresh
}
STATUS current
DESCRIPTION
"A collection of objects that support thresholds on optical
parameters and provide status information when the thresholds
are exceeded or cleared."
::={ cerentOpticalMonitorMIBGroups 2 }
cerentOpticalMIBPMGroup OBJECT-GROUP
OBJECTS {
cOpticalPMCurrentMaxParam,
cOpticalPMCurrentMinParam,
cOpticalPMCurrentMeanParam,
cOpticalPMIntervalMaxParam,
cOpticalPMIntervalMinParam,
cOpticalPMIntervalMeanParam,
cOpticalPMIntervalValidData
}
STATUS current
DESCRIPTION
"A collection of objects that provide optical performance
monitoring data for 15 minute and 24 hour intervals."
::={ cerentOpticalMonitorMIBGroups 3 }
cerentOpticalDwdmNetworkMIBThresholdGroup OBJECT-GROUP
OBJECTS {
cOpticalParamHighAlarmThresh,
cOpticalParamHighWarning15MinThresh,
cOpticalParamHighWarning1DayThresh,
cOpticalParamLowAlarmThresh,
cOpticalParamLowWarning15MinThresh,
cOpticalParamLowWarning1DayThresh,
cOpticalParamLowDegradeThresh,
cOpticalParamHighDegradeThresh
}
STATUS current
DESCRIPTION
"A collection of objects that support thresholds on optical
DWDM Network parameters and provide status information when
the thresholds are exceeded or cleared."
::={ cerentOpticalMonitorMIBGroups 4 }
END