701 lines
24 KiB
Plaintext
701 lines
24 KiB
Plaintext
-- *****************************************************************
|
|
-- CERENT-OPTICAL-MONITOR-MIB.mib
|
|
--
|
|
-- Copyright (c) 2002 by Cisco Systems, Inc.
|
|
-- All rights reserved.
|
|
-- *****************************************************************
|
|
|
|
|
|
CERENT-OPTICAL-MONITOR-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
Integer32,
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION,
|
|
TruthValue FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP FROM SNMPv2-CONF
|
|
ifIndex FROM IF-MIB
|
|
cerentModules,
|
|
cerentRequirements,
|
|
cerentGeneric FROM CERENT-GLOBAL-REGISTRY
|
|
CerentPeriod FROM CERENT-TC
|
|
;
|
|
|
|
cerentOpticalMonitorMIB MODULE-IDENTITY
|
|
LAST-UPDATED "0211110000Z" -- 2002/Nov/11
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
CONTACT-INFO "support@Cisco.com
|
|
|
|
Postal:
|
|
Cisco Systems
|
|
1450 N. McDowell Blvd.
|
|
Petaluma, CA 94954
|
|
|
|
Tel: +1-877-323-7368"
|
|
DESCRIPTION
|
|
"This MIB module defines objects to monitor optical
|
|
characteristics and set corresponding thresholds, on the
|
|
optical interfaces in a network element.
|
|
This module is an adaptation of CISCO-OPTICAL-MONITOR-MIB.
|
|
"
|
|
REVISION "0211110000Z" -- 2002/Nov/11
|
|
DESCRIPTION
|
|
"The initial revision of this MIB."
|
|
::={ cerentModules 70 }
|
|
|
|
|
|
-- Textual Conventions
|
|
|
|
OpticalParameterType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value indicates the optical parameter that is
|
|
being monitored. Valid values are -
|
|
|
|
power (1) : Optical Power (AC + DC).
|
|
acPower (2) : Optical AC Power.
|
|
apdTemp (3) : Avalanche Photo Detector Temperature.
|
|
laserTemp (4) : Laser Temperature.
|
|
biasCurrent (5) : Laser bias current.
|
|
peltierCurrent (6) : Laser peltier current.
|
|
xcvrVoltage (7) : Transceiver voltage.
|
|
voa (8) : Variable Optical Attenuation Failure & Degrade Th.
|
|
gain (9) : Optical amplifier gain Failure & Degrade Th.
|
|
oscPower (10) : OSC Optical Power
|
|
addPower (11) : Add Optical Power
|
|
"
|
|
SYNTAX INTEGER {
|
|
power(1),
|
|
acPower(2),
|
|
apdTemp(3),
|
|
laserTemp(4),
|
|
biasCurrent(5),
|
|
peltierCurrent(6),
|
|
xcvrVoltage(7),
|
|
voa(8),
|
|
gain(9),
|
|
oscPower(10),
|
|
addPower(11)
|
|
}
|
|
|
|
|
|
OpticalParameterValue ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of the optical parameter that is being monitored.
|
|
|
|
The range of values varies depending on the type of optical
|
|
parameter being monitored, as identified by a corresponding
|
|
object with syntax OpticalParameterType.
|
|
|
|
when the optical parameter being monitored is 'power' or
|
|
'acpower', the supported range is from -1000 to 1000, in
|
|
1/10ths of dBm.
|
|
Example: Actual power of -40 dbm is represented as -400.
|
|
Actual power level of +30 dBm is represented as 300.
|
|
|
|
When the optical parameter being monitored is 'laserTemp' or
|
|
'apdTemp', the supported range is from -10000 to 30000, in
|
|
1/100ths of degrees centigrade.
|
|
Example: A value of 2355 represents a temperature reading of
|
|
23.55 degrees C.
|
|
|
|
When the optical parameter being monitored is 'biasCurrent',
|
|
the supported range is from 0 to 1000, in 1/10ths of
|
|
percentage (%).
|
|
Example: A value of 500 represents a bias current threshold
|
|
of 50.0 %.
|
|
|
|
When the optical parameter being monitored is 'peltierCurrent',
|
|
the supported range is from 0 to 10000, in milliamperes.
|
|
|
|
When the optical parameter being monitored is 'xcvrVoltage',
|
|
the supported range is from 0 to 100000, in 1/10ths of
|
|
millivolts.
|
|
Example: A Value of 115 represents a transceiver voltage
|
|
reading of 11.5 millivolts.
|
|
|
|
The distinguished value of '-1000000' indicates that the object
|
|
has not yet been initialized or does not apply.
|
|
"
|
|
SYNTAX Integer32 ( -1000000..1000000 )
|
|
|
|
|
|
OpticalIfDirection ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value indicates the direction being monitored at
|
|
the optical interface.
|
|
"
|
|
SYNTAX INTEGER {
|
|
receive(1),
|
|
transmit(2),
|
|
notApplicable(3)
|
|
}
|
|
|
|
|
|
-- MIB Object Definitions
|
|
|
|
cerentOpticalMonitorMIBObjects OBJECT IDENTIFIER ::=
|
|
{cerentGeneric 30 }
|
|
|
|
-- groups in this MIB module
|
|
|
|
cerentOpticalMonGroup OBJECT IDENTIFIER ::=
|
|
{cerentOpticalMonitorMIBObjects 1 }
|
|
|
|
cerentOpticalPMGroup OBJECT IDENTIFIER ::=
|
|
{cerentOpticalMonitorMIBObjects 2 }
|
|
|
|
-- cOpticalMonTable
|
|
|
|
cOpticalMonTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF COpticalMonEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides objects to monitor optical
|
|
parameters in a network element. It also provides
|
|
objects for setting high and low threshold levels, with
|
|
configurable severities, on these monitored parameters."
|
|
::={ cerentOpticalMonGroup 1 }
|
|
|
|
cOpticalMonEntry OBJECT-TYPE
|
|
SYNTAX COpticalMonEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the cOpticalMonTable provides objects to
|
|
monitor an optical parameter and set threshold levels
|
|
on that parameter, at an optical interface.
|
|
|
|
Note that the set of monitored optical parameters may vary
|
|
based on interface type and direction.
|
|
|
|
Examples of interfaces that can have an entry in this table
|
|
include optical transceivers optical amplifiers,
|
|
and optical attenuators."
|
|
INDEX { ifIndex, cOpticalMonDirection,
|
|
cOpticalMonParameterType }
|
|
::={ cOpticalMonTable 1 }
|
|
|
|
|
|
COpticalMonEntry ::= SEQUENCE {
|
|
cOpticalMonDirection OpticalIfDirection,
|
|
cOpticalMonParameterType OpticalParameterType,
|
|
cOpticalParameterValue OpticalParameterValue,
|
|
cOpticalParamHighAlarmThresh OpticalParameterValue,
|
|
cOpticalParamHighWarning15MinThresh OpticalParameterValue,
|
|
cOpticalParamHighWarning1DayThresh OpticalParameterValue,
|
|
cOpticalParamLowAlarmThresh OpticalParameterValue,
|
|
cOpticalParamLowWarning15MinThresh OpticalParameterValue,
|
|
cOpticalParamLowWarning1DayThresh OpticalParameterValue,
|
|
cOpticalParamLowDegradeThresh OpticalParameterValue,
|
|
cOpticalParamHighDegradeThresh OpticalParameterValue
|
|
}
|
|
|
|
cOpticalMonDirection OBJECT-TYPE
|
|
SYNTAX OpticalIfDirection
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an index into the cOpticalMonTable
|
|
and indicates the direction monitored for the
|
|
optical interface, in this entry."
|
|
::={ cOpticalMonEntry 1 }
|
|
|
|
|
|
cOpticalMonParameterType OBJECT-TYPE
|
|
SYNTAX OpticalParameterType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an index into the cOpticalMonTable
|
|
and specifies the optical parameter that is being monitored,
|
|
in this entry."
|
|
::={ cOpticalMonEntry 2 }
|
|
|
|
cOpticalParameterValue OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object gives the value measured for the particular
|
|
optical parameter specified by the cOpticalMonParameterType
|
|
object."
|
|
::={ cOpticalMonEntry 3 }
|
|
|
|
cOpticalParamHighAlarmThresh OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to set a high alarm threshold on the
|
|
optical parameter being monitored.
|
|
|
|
If the measured value of the parameter,is greater than the
|
|
value configured in this object, an alarm will be raised.
|
|
|
|
When the cOpticalMonParameterType object is set to 'power'
|
|
for the receive direction at a transceiver, this object
|
|
specifies the receiver saturation level."
|
|
::={ cOpticalMonEntry 4 }
|
|
|
|
|
|
cOpticalParamHighWarning15MinThresh OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to set a high warning 15 minute threshold
|
|
on the optical parameter being monitored.
|
|
|
|
If the measured value of the parameter,is greater than the
|
|
value configured in this object, an alarm may be raised."
|
|
::={ cOpticalMonEntry 5 }
|
|
|
|
cOpticalParamHighWarning1DayThresh OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to set a high warning 1 day threshold on
|
|
the optical parameter being monitored.
|
|
|
|
If the measured value of the parameter,is greater than the
|
|
value configured in this object, an alarm may be raised."
|
|
::={ cOpticalMonEntry 6 }
|
|
|
|
cOpticalParamLowAlarmThresh OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to set a low alarm threshold on the
|
|
optical parameter being monitored.
|
|
|
|
If the measured value of the parameter,goes lower than the
|
|
value configured in this object, an alarm will be raised.
|
|
|
|
When the cOpticalMonParameterType object is set to 'power'
|
|
for the receive direction and when the interface supports
|
|
alarms based on loss of light, this object specifies the
|
|
optical power threshold for declaring loss of light. Also,
|
|
when optical amplifiers are present in the network, in the
|
|
receive direction, this value may need to be configured,
|
|
since the noise floor may be higher than the minimum
|
|
sensitivity of the receiver."
|
|
::={ cOpticalMonEntry 7 }
|
|
|
|
cOpticalParamLowWarning15MinThresh OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to set a low warning 15 minute threshold
|
|
on the optical parameter being monitored.
|
|
|
|
If the measured value of the parameter,goes lower than the
|
|
value configured in this object, an alarm will be raised."
|
|
::={ cOpticalMonEntry 8 }
|
|
|
|
cOpticalParamLowWarning1DayThresh OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to set a low warning 1 day threshold
|
|
on the optical parameter being monitored.
|
|
|
|
If the measured value of the parameter,goes lower than the
|
|
value configured in this object, an alarm will be raised."
|
|
::={ cOpticalMonEntry 9 }
|
|
|
|
cOpticalParamLowDegradeThresh OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to set a low degrade threshold
|
|
on the optical parameter being monitored.
|
|
|
|
If the measured value of the parameter,goes lower than the
|
|
value configured in this object, a degrade alarm will be raised."
|
|
::={ cOpticalMonEntry 10 }
|
|
|
|
cOpticalParamHighDegradeThresh OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to set a high degrade threshold
|
|
on the optical parameter being monitored.
|
|
|
|
If the measured value of the parameter,goes lower than the
|
|
value configured in this object, a degrade alarm will be raised."
|
|
::={ cOpticalMonEntry 11 }
|
|
|
|
|
|
-- cOpticalPMCurrent Table
|
|
|
|
cOpticalPMCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF COpticalPMCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table stores performance monitoring data for the
|
|
various optical parameters, collected over the current
|
|
interval."
|
|
::={ cerentOpticalPMGroup 1 }
|
|
|
|
cOpticalPMCurrentEntry OBJECT-TYPE
|
|
SYNTAX COpticalPMCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the cOpticalPMCurrentTable. It contains
|
|
performance monitoring data for an optical parameter,
|
|
collected over the current interval.
|
|
|
|
Note that the set of monitored optical parameters may vary
|
|
based on interface type and direction.
|
|
|
|
Examples of interfaces that can have an entry in this table
|
|
include optical transceivers, optical amplifiers, and optical
|
|
attenuators."
|
|
INDEX { ifIndex,
|
|
cOpticalPMCurrentDirection,
|
|
cOpticalPMCurrentParamType,
|
|
cOpticalPMCurrentPeriod}
|
|
::={ cOpticalPMCurrentTable 1 }
|
|
|
|
COpticalPMCurrentEntry ::= SEQUENCE {
|
|
cOpticalPMCurrentDirection OpticalIfDirection,
|
|
cOpticalPMCurrentParamType OpticalParameterType,
|
|
cOpticalPMCurrentPeriod CerentPeriod,
|
|
cOpticalPMCurrentMaxParam OpticalParameterValue,
|
|
cOpticalPMCurrentMinParam OpticalParameterValue,
|
|
cOpticalPMCurrentMeanParam OpticalParameterValue
|
|
}
|
|
|
|
|
|
cOpticalPMCurrentDirection OBJECT-TYPE
|
|
SYNTAX OpticalIfDirection
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an index into the cOpticalPMCurrentTable
|
|
and indicates the direction monitored
|
|
for the optical interface, in this entry."
|
|
::={ cOpticalPMCurrentEntry 1 }
|
|
|
|
cOpticalPMCurrentParamType OBJECT-TYPE
|
|
SYNTAX OpticalParameterType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an index into the
|
|
cOpticalPMCurrentTable and specifies the optical parameter
|
|
that is being monitored, in this entry."
|
|
::={ cOpticalPMCurrentEntry 2 }
|
|
|
|
cOpticalPMCurrentPeriod OBJECT-TYPE
|
|
SYNTAX CerentPeriod
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an index into the
|
|
cOpticalPMCurrentTable and indicates whether the
|
|
optical parameter values given in this entry, are collected
|
|
over a period of 15 minutes or 24 hours."
|
|
::={ cOpticalPMCurrentEntry 3 }
|
|
|
|
cOpticalPMCurrentMaxParam OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object gives the maximum value measured for the optical
|
|
parameter, in the current 15 minute or 24 hour interval."
|
|
::={ cOpticalPMCurrentEntry 4 }
|
|
|
|
cOpticalPMCurrentMinParam OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object gives the minimum value measured for the optical
|
|
parameter, in the current 15 minute or 24 hour interval."
|
|
::={ cOpticalPMCurrentEntry 5 }
|
|
|
|
cOpticalPMCurrentMeanParam OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object gives the average value of the measured optical
|
|
parameter, in the current 15 minute or 24 hour interval."
|
|
::={ cOpticalPMCurrentEntry 6 }
|
|
|
|
-- cOpticalPMInterval Table
|
|
|
|
cOpticalPMIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF COpticalPMIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table stores performance monitoring data for the
|
|
various optical parameters, collected over current and
|
|
previous intervals.
|
|
|
|
This table can have entries for up to 96 complete 15 minute
|
|
intervals."
|
|
::={ cerentOpticalPMGroup 2 }
|
|
|
|
cOpticalPMIntervalEntry OBJECT-TYPE
|
|
SYNTAX COpticalPMIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the cOpticalPMIntervalTable. It contains
|
|
performance monitoring data for an optical parameter,
|
|
collected over current and previous intervals.
|
|
|
|
Note that the set of monitored optical parameters may vary
|
|
based on interface type and direction.
|
|
|
|
Examples of interfaces that can have an entry in this table
|
|
include optical transceivers, optical amplifiers, and optical
|
|
attenuators."
|
|
INDEX { ifIndex,
|
|
cOpticalPMIntervalDirection,
|
|
cOpticalPMIntervalParamType,
|
|
cOpticalPMIntervalPeriod,
|
|
cOpticalPMIntervalNumber}
|
|
::={ cOpticalPMIntervalTable 1 }
|
|
|
|
COpticalPMIntervalEntry ::= SEQUENCE {
|
|
cOpticalPMIntervalDirection OpticalIfDirection,
|
|
cOpticalPMIntervalParamType OpticalParameterType,
|
|
cOpticalPMIntervalPeriod CerentPeriod,
|
|
cOpticalPMIntervalNumber Integer32,
|
|
cOpticalPMIntervalMaxParam OpticalParameterValue,
|
|
cOpticalPMIntervalMinParam OpticalParameterValue,
|
|
cOpticalPMIntervalMeanParam OpticalParameterValue,
|
|
cOpticalPMIntervalValidData TruthValue
|
|
}
|
|
|
|
|
|
cOpticalPMIntervalDirection OBJECT-TYPE
|
|
SYNTAX OpticalIfDirection
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an index into the cOpticalPMIntervalTable
|
|
and indicates the direction monitored
|
|
for the optical interface, in this entry."
|
|
::={ cOpticalPMIntervalEntry 1 }
|
|
|
|
cOpticalPMIntervalParamType OBJECT-TYPE
|
|
SYNTAX OpticalParameterType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an index into the
|
|
cOpticalPMIntervalTable and specifies the optical parameter
|
|
that is being monitored, in this entry."
|
|
::={ cOpticalPMIntervalEntry 2 }
|
|
|
|
cOpticalPMIntervalPeriod OBJECT-TYPE
|
|
SYNTAX CerentPeriod
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an index into the
|
|
cOpticalPMIntervalTable and indicates whether the
|
|
optical parameter values given in this entry, are collected
|
|
over a period of 15 minutes or 24 hours."
|
|
::={ cOpticalPMIntervalEntry 3 }
|
|
|
|
cOpticalPMIntervalNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an index into the cOpticalPMIntervalTable.
|
|
It is a number between 1 and 96, which identifies the
|
|
interval for which the set of optical parameter values is
|
|
available. The interval identified by 1 is the most recent
|
|
15 minute or 24 hour interval, and the interval
|
|
identified by N is the interval immediately preceding the one
|
|
identified by N-1."
|
|
::={ cOpticalPMIntervalEntry 4 }
|
|
|
|
cOpticalPMIntervalMaxParam OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object gives the maximum value measured for the optical
|
|
parameter, in a particular 15 minute or 24 hour interval."
|
|
::={ cOpticalPMIntervalEntry 5 }
|
|
|
|
cOpticalPMIntervalMinParam OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object gives the minimum value measured for the optical
|
|
parameter, in a particular 15 minute or 24 hour interval."
|
|
::={ cOpticalPMIntervalEntry 6 }
|
|
|
|
cOpticalPMIntervalMeanParam OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object gives the average value of the measured optical
|
|
parameter, in a particular 15 minute or 24 hour interval."
|
|
::={ cOpticalPMIntervalEntry 7 }
|
|
|
|
cOpticalPMIntervalValidData OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates if the data for this
|
|
interval is valid."
|
|
::= { cOpticalPMIntervalEntry 8 }
|
|
|
|
|
|
-- MIB Conformance Statements
|
|
|
|
cerentOpticalMonitorMIBConformance OBJECT IDENTIFIER ::=
|
|
{ cerentRequirements 20 }
|
|
|
|
cerentOpticalMonitorMIBCompliances OBJECT IDENTIFIER ::=
|
|
{ cerentOpticalMonitorMIBConformance 1 }
|
|
|
|
cerentOpticalMonitorMIBGroups OBJECT IDENTIFIER ::=
|
|
{ cerentOpticalMonitorMIBConformance 2 }
|
|
|
|
|
|
cerentOpticalMonitorMIBCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for network elements that
|
|
monitor optical characteristics and set thresholds on the
|
|
optical interfaces in a network element."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { cerentOpticalMIBMonGroup }
|
|
|
|
GROUP cerentOpticalMIBThresholdGroup
|
|
DESCRIPTION
|
|
"This group is required for network elements that support
|
|
thresholds on optical parameters."
|
|
|
|
GROUP cerentOpticalMIBPMGroup
|
|
DESCRIPTION
|
|
"This group is required for network elements that
|
|
support collection of optical performance monitoring
|
|
data for 15 minute or 24 hour intervals."
|
|
|
|
OBJECT cOpticalParamHighAlarmThresh
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cOpticalParamHighWarning15MinThresh
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cOpticalParamHighWarning1DayThresh
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cOpticalParamLowAlarmThresh
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cOpticalParamLowWarning15MinThresh
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT cOpticalParamLowWarning1DayThresh
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
::={ cerentOpticalMonitorMIBCompliances 1 }
|
|
|
|
-- Units of Conformance
|
|
|
|
cerentOpticalMIBMonGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cOpticalParameterValue
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A mandatory object that provides monitoring of optical
|
|
characteristics."
|
|
::={ cerentOpticalMonitorMIBGroups 1 }
|
|
|
|
cerentOpticalMIBThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cOpticalParamHighAlarmThresh,
|
|
cOpticalParamHighWarning15MinThresh,
|
|
cOpticalParamHighWarning1DayThresh,
|
|
cOpticalParamLowAlarmThresh,
|
|
cOpticalParamLowWarning15MinThresh,
|
|
cOpticalParamLowWarning1DayThresh
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects that support thresholds on optical
|
|
parameters and provide status information when the thresholds
|
|
are exceeded or cleared."
|
|
::={ cerentOpticalMonitorMIBGroups 2 }
|
|
|
|
cerentOpticalMIBPMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cOpticalPMCurrentMaxParam,
|
|
cOpticalPMCurrentMinParam,
|
|
cOpticalPMCurrentMeanParam,
|
|
cOpticalPMIntervalMaxParam,
|
|
cOpticalPMIntervalMinParam,
|
|
cOpticalPMIntervalMeanParam,
|
|
cOpticalPMIntervalValidData
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects that provide optical performance
|
|
monitoring data for 15 minute and 24 hour intervals."
|
|
::={ cerentOpticalMonitorMIBGroups 3 }
|
|
|
|
cerentOpticalDwdmNetworkMIBThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cOpticalParamHighAlarmThresh,
|
|
cOpticalParamHighWarning15MinThresh,
|
|
cOpticalParamHighWarning1DayThresh,
|
|
cOpticalParamLowAlarmThresh,
|
|
cOpticalParamLowWarning15MinThresh,
|
|
cOpticalParamLowWarning1DayThresh,
|
|
cOpticalParamLowDegradeThresh,
|
|
cOpticalParamHighDegradeThresh
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects that support thresholds on optical
|
|
DWDM Network parameters and provide status information when
|
|
the thresholds are exceeded or cleared."
|
|
::={ cerentOpticalMonitorMIBGroups 4 }
|
|
|
|
END
|
|
|