mibs/MIBS/cisco/CISCOSB-PHY-MIB

231 lines
7.2 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
CISCOSB-PHY-MIB DEFINITIONS ::= BEGIN
-- Title: CISCOSB PHY MIB
-- Version: 7.38
-- Date: 10 Sep 2004
--
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI
ifIndex FROM IF-MIB
TimeStamp, DisplayString FROM SNMPv2-TC
switch001 FROM CISCOSB-MIB
TEXTUAL-CONVENTION FROM SNMPv2-TC;
rlPhy MODULE-IDENTITY
LAST-UPDATED "200409100000Z" -- September 30, 2002
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
"Postal: 170 West Tasman Drive
San Jose , CA 95134-1706
USA
Website: Cisco Small Business Support Community <http://www.cisco.com/go/smallbizsupport>"
DESCRIPTION
"The MIB module describes the private MIB for testing Layer1 interfaces supported
by CISCOSB's software and products."
REVISION "200209300024Z" -- September 30, 2002
DESCRIPTION
"Initial revision"
REVISION "200309210024Z" -- September 21, 2003
DESCRIPTION
"Added MODULE-IDENTITY and TEXTUAL-CONVENTION IMPORTS."
::= { switch001 90 }
RlPhyTestType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A value indicating the test to perform."
SYNTAX INTEGER {
rlPhyTestTableNoTest(1),
rlPhyTestTableCableStatus(2),
rlPhyTestTableCableFault(3),
rlPhyTestTableCableLength(4),
rlPhyTestTableTransceiverTemp(5),
rlPhyTestTableTransceiverSupply(6),
rlPhyTestTableTxBias(7),
rlPhyTestTableTxOutput(8),
rlPhyTestTableRxOpticalPower(9),
rlPhyTestTableDataReady(10),
rlPhyTestTableLOS(11),
rlPhyTestTableTxFault(12),
rlPhyTestTableCableChannel1(13),
rlPhyTestTableCableChannel2(14),
rlPhyTestTableCableChannel3(15),
rlPhyTestTableCableChannel4(16),
rlPhyTestTableCablePolarity1(17),
rlPhyTestTableCablePolarity2(18),
rlPhyTestTableCablePolarity3(19),
rlPhyTestTableCablePolarity4(20),
rlPhyTestTableCablePairSkew1(21),
rlPhyTestTableCablePairSkew2(22),
rlPhyTestTableCablePairSkew3(23),
rlPhyTestTableCablePairSkew4(24),
rlPhyTestTableSFPEepromQualified(25)
}
rlPhyTest OBJECT IDENTIFIER ::= { rlPhy 1 }
rlPhyTestSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlPhyTestSetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { rlPhyTest 1}
rlPhyTestSetEntry OBJECT-TYPE
SYNTAX RlPhyTestSetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing objects for invoking tests on an interface."
INDEX {ifIndex }
::= { rlPhyTestSetTable 1 }
RlPhyTestSetEntry ::=
SEQUENCE {
rlPhyTestSetType RlPhyTestType
}
rlPhyTestSetType OBJECT-TYPE
SYNTAX RlPhyTestType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A control variable used to start operator initiated interface
tests.1 indicates that no test has been initiated. Only
operator initiated interface tests can be set to this variable."
::= { rlPhyTestSetEntry 1 }
rlPhyTestGetTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlPhyTestGetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { rlPhyTest 2 }
rlPhyTestGetEntry OBJECT-TYPE
SYNTAX RlPhyTestGetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing results of tests on an interface."
INDEX {ifIndex, rlPhyTestGetType}
::= { rlPhyTestGetTable 1 }
RlPhyTestGetEntry ::=
SEQUENCE {
rlPhyTestGetType RlPhyTestType,
rlPhyTestGetStatus INTEGER,
rlPhyTestGetResult INTEGER,
rlPhyTestGetUnits INTEGER,
rlPhyTestGetAlarm INTEGER,
rlPhyTestGetTimeStamp DisplayString
}
rlPhyTestGetType OBJECT-TYPE
SYNTAX RlPhyTestType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A control variable used to, 1 to indicate that this test can be
done on the specified port, 2 to initiate the test whenever the
user wishes"
::= { rlPhyTestGetEntry 1 }
rlPhyTestGetStatus OBJECT-TYPE
SYNTAX INTEGER {
none(1), -- no test yet requested
success(2),
inProgress(3),
notSupported(4),
unAbleToRun(5), -- due to state of system
aborted(6),
failed(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the status of the most recently
requested test for operator initiated tests or the value
none(1) if no tests have been requested since the last
reset. For non operator initiated tests the value is always
none(1).
Note that this facility provides no provision for saving
the results of one test when starting another, as could
be required if used by multiple managers concurrently."
::= { rlPhyTestGetEntry 2 }
rlPhyTestGetResult OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the test result"
::= { rlPhyTestGetEntry 3 }
rlPhyTestGetUnits OBJECT-TYPE
SYNTAX INTEGER {
integer(1),
boolean(2),
downUP(3),
reverseNormal(4),
mdiMdix(5),
meter(6),
degree(7), -- Celsius
microVolt(8),
microOham(9),
microAmper(10),
microWatt(11),
millisecond(12),
alaskaPhyLength(13),
alaskaPhyStatus(14),
dbm(15),
decidbm(16),
milidbm(17),
abcd(18),
nanosecond(19)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The test result unit of measure. The units can be standard unit or special units
that are designed for special test.
The alaskaPhyLength unit is design for the VCT diagnostic and its values are:
less-than-50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more-than-140M(5).
The alaskaPhyStatus unit is design for the VCT diagnostic and its values are:
4-pair-cable(1), 2-pair-cable(2), no-cable(3), open-cable(4), short-cable(5), bad-cable(6), impedance-mismatch(7)."
::= { rlPhyTestGetEntry 4 }
rlPhyTestGetAlarm OBJECT-TYPE
SYNTAX INTEGER {
notRelevant(1),
noAlarmSet(2),
lowWarning(3),
highWarning(4),
lowAlarm(5),
highAlarm(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object hold the Alarm for this Entry. only Test that have can have alarms
use this field, other holds the Value notRelevant(1) "
::= { rlPhyTestGetEntry 5 }
rlPhyTestGetTimeStamp OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time in string (formated DD-MMM-YYYY HH:MM:SS e.g
14-Apr-2002 10:33:31)"
::= { rlPhyTestGetEntry 6 }
END