CISCOSB-PHY-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
-- Title:      CISCOSB PHY MIB
 | 
						|
-- Version:    7.38
 | 
						|
-- Date:       10 Sep 2004
 | 
						|
--
 | 
						|
IMPORTS
 | 
						|
    OBJECT-TYPE, MODULE-IDENTITY                FROM SNMPv2-SMI
 | 
						|
    ifIndex                                     FROM IF-MIB
 | 
						|
    TimeStamp, DisplayString                    FROM SNMPv2-TC
 | 
						|
    switch001                                   FROM CISCOSB-MIB
 | 
						|
    TEXTUAL-CONVENTION                          FROM SNMPv2-TC;
 | 
						|
 | 
						|
   rlPhy MODULE-IDENTITY
 | 
						|
      LAST-UPDATED "200409100000Z"  -- September 30, 2002
 | 
						|
      ORGANIZATION "Cisco Systems, Inc."
 | 
						|
 | 
						|
      CONTACT-INFO
 | 
						|
      "Postal: 170 West Tasman Drive
 | 
						|
      San Jose , CA 95134-1706
 | 
						|
      USA
 | 
						|
 | 
						|
      
 | 
						|
      Website:  Cisco Small Business Support Community <http://www.cisco.com/go/smallbizsupport>"
 | 
						|
 | 
						|
      DESCRIPTION
 | 
						|
              "The MIB module describes the private MIB for testing Layer1 interfaces supported
 | 
						|
               by CISCOSB's software and products."
 | 
						|
      REVISION     "200209300024Z"  -- September 30, 2002
 | 
						|
      DESCRIPTION
 | 
						|
              "Initial revision"
 | 
						|
      REVISION     "200309210024Z"  -- September 21, 2003
 | 
						|
      DESCRIPTION
 | 
						|
              "Added MODULE-IDENTITY and TEXTUAL-CONVENTION IMPORTS."
 | 
						|
      ::= { switch001 90  }
 | 
						|
 | 
						|
 | 
						|
RlPhyTestType ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS          current
 | 
						|
    DESCRIPTION
 | 
						|
        "A value indicating the test to perform."
 | 
						|
   SYNTAX  INTEGER {
 | 
						|
        rlPhyTestTableNoTest(1),
 | 
						|
        rlPhyTestTableCableStatus(2),
 | 
						|
        rlPhyTestTableCableFault(3),
 | 
						|
        rlPhyTestTableCableLength(4),
 | 
						|
        rlPhyTestTableTransceiverTemp(5),
 | 
						|
        rlPhyTestTableTransceiverSupply(6),
 | 
						|
        rlPhyTestTableTxBias(7),
 | 
						|
        rlPhyTestTableTxOutput(8),
 | 
						|
        rlPhyTestTableRxOpticalPower(9),
 | 
						|
        rlPhyTestTableDataReady(10),
 | 
						|
        rlPhyTestTableLOS(11),
 | 
						|
        rlPhyTestTableTxFault(12),
 | 
						|
        rlPhyTestTableCableChannel1(13),
 | 
						|
        rlPhyTestTableCableChannel2(14),
 | 
						|
        rlPhyTestTableCableChannel3(15),
 | 
						|
        rlPhyTestTableCableChannel4(16),
 | 
						|
        rlPhyTestTableCablePolarity1(17),
 | 
						|
        rlPhyTestTableCablePolarity2(18),
 | 
						|
        rlPhyTestTableCablePolarity3(19),
 | 
						|
        rlPhyTestTableCablePolarity4(20),
 | 
						|
        rlPhyTestTableCablePairSkew1(21),
 | 
						|
        rlPhyTestTableCablePairSkew2(22),
 | 
						|
        rlPhyTestTableCablePairSkew3(23),
 | 
						|
        rlPhyTestTableCablePairSkew4(24),
 | 
						|
        rlPhyTestTableSFPEepromQualified(25)
 | 
						|
    }
 | 
						|
 | 
						|
rlPhyTest OBJECT IDENTIFIER ::= { rlPhy 1 }
 | 
						|
 | 
						|
rlPhyTestSetTable   OBJECT-TYPE
 | 
						|
    SYNTAX SEQUENCE OF RlPhyTestSetEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION ""
 | 
						|
    ::= { rlPhyTest 1}
 | 
						|
 | 
						|
rlPhyTestSetEntry OBJECT-TYPE
 | 
						|
    SYNTAX       RlPhyTestSetEntry
 | 
						|
    MAX-ACCESS   not-accessible
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION
 | 
						|
            "An entry containing objects for invoking tests on an interface."
 | 
						|
    INDEX {ifIndex }
 | 
						|
    ::= { rlPhyTestSetTable 1 }
 | 
						|
 | 
						|
RlPhyTestSetEntry ::=
 | 
						|
    SEQUENCE {
 | 
						|
        rlPhyTestSetType        RlPhyTestType
 | 
						|
    }
 | 
						|
 | 
						|
rlPhyTestSetType       OBJECT-TYPE
 | 
						|
    SYNTAX  RlPhyTestType
 | 
						|
    MAX-ACCESS   read-write
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION
 | 
						|
            "A control variable used to start operator initiated interface
 | 
						|
             tests.1 indicates that no test has been initiated. Only
 | 
						|
             operator initiated interface tests can be set to this variable."
 | 
						|
              ::= { rlPhyTestSetEntry 1 }
 | 
						|
 | 
						|
rlPhyTestGetTable   OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF RlPhyTestGetEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION ""
 | 
						|
    ::= { rlPhyTest 2 }
 | 
						|
 | 
						|
rlPhyTestGetEntry OBJECT-TYPE
 | 
						|
    SYNTAX       RlPhyTestGetEntry
 | 
						|
    MAX-ACCESS   not-accessible
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION
 | 
						|
            "An entry containing results of tests on an interface."
 | 
						|
    INDEX {ifIndex, rlPhyTestGetType}
 | 
						|
    ::= { rlPhyTestGetTable 1 }
 | 
						|
 | 
						|
RlPhyTestGetEntry ::=
 | 
						|
    SEQUENCE {
 | 
						|
        rlPhyTestGetType        RlPhyTestType,
 | 
						|
        rlPhyTestGetStatus      INTEGER,
 | 
						|
        rlPhyTestGetResult      INTEGER,
 | 
						|
        rlPhyTestGetUnits       INTEGER,
 | 
						|
        rlPhyTestGetAlarm       INTEGER,
 | 
						|
        rlPhyTestGetTimeStamp   DisplayString
 | 
						|
    }
 | 
						|
 | 
						|
rlPhyTestGetType       OBJECT-TYPE
 | 
						|
    SYNTAX     RlPhyTestType
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "A control variable used to, 1 to indicate that this test can be
 | 
						|
            done on the specified port, 2 to initiate the test whenever the
 | 
						|
            user wishes"
 | 
						|
              ::= { rlPhyTestGetEntry 1 }
 | 
						|
 | 
						|
rlPhyTestGetStatus  OBJECT-TYPE
 | 
						|
    SYNTAX       INTEGER {
 | 
						|
        none(1),          -- no test yet requested
 | 
						|
        success(2),
 | 
						|
        inProgress(3),
 | 
						|
        notSupported(4),
 | 
						|
        unAbleToRun(5),   -- due to state of system
 | 
						|
        aborted(6),
 | 
						|
        failed(7)
 | 
						|
                 }
 | 
						|
    MAX-ACCESS   read-only
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION
 | 
						|
        "This object contains the status of the most recently
 | 
						|
        requested test for operator initiated tests or the value
 | 
						|
        none(1) if no tests have been requested since the last
 | 
						|
        reset. For non operator initiated tests the value is always
 | 
						|
        none(1).
 | 
						|
        Note that this facility provides no provision for saving
 | 
						|
        the results of one test when starting another, as could
 | 
						|
        be required if used by multiple managers concurrently."
 | 
						|
    ::= { rlPhyTestGetEntry 2 }
 | 
						|
 | 
						|
rlPhyTestGetResult  OBJECT-TYPE
 | 
						|
    SYNTAX       INTEGER
 | 
						|
    MAX-ACCESS   read-only
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION
 | 
						|
            "This object holds the test result"
 | 
						|
    ::= { rlPhyTestGetEntry 3 }
 | 
						|
 | 
						|
rlPhyTestGetUnits   OBJECT-TYPE
 | 
						|
   SYNTAX  INTEGER {
 | 
						|
        integer(1),
 | 
						|
        boolean(2),
 | 
						|
        downUP(3),
 | 
						|
        reverseNormal(4),
 | 
						|
        mdiMdix(5),
 | 
						|
        meter(6),
 | 
						|
        degree(7),  -- Celsius
 | 
						|
        microVolt(8),
 | 
						|
        microOham(9),
 | 
						|
        microAmper(10),
 | 
						|
        microWatt(11),
 | 
						|
        millisecond(12),
 | 
						|
        alaskaPhyLength(13),
 | 
						|
        alaskaPhyStatus(14),
 | 
						|
        dbm(15),
 | 
						|
        decidbm(16),
 | 
						|
        milidbm(17),
 | 
						|
        abcd(18),
 | 
						|
        nanosecond(19)
 | 
						|
            }
 | 
						|
    MAX-ACCESS   read-only
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION
 | 
						|
        "The test result unit of measure. The units can be standard unit or special units
 | 
						|
         that are designed for special test.
 | 
						|
 | 
						|
         The alaskaPhyLength unit is design for the VCT diagnostic and its values are:
 | 
						|
         less-than-50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more-than-140M(5).
 | 
						|
 | 
						|
         The alaskaPhyStatus unit is design for the VCT diagnostic and its values are:
 | 
						|
         4-pair-cable(1), 2-pair-cable(2), no-cable(3), open-cable(4), short-cable(5), bad-cable(6), impedance-mismatch(7)."
 | 
						|
   ::= { rlPhyTestGetEntry 4 }
 | 
						|
 | 
						|
rlPhyTestGetAlarm   OBJECT-TYPE
 | 
						|
   SYNTAX  INTEGER {
 | 
						|
        notRelevant(1),
 | 
						|
        noAlarmSet(2),
 | 
						|
        lowWarning(3),
 | 
						|
        highWarning(4),
 | 
						|
        lowAlarm(5),
 | 
						|
        highAlarm(6)
 | 
						|
   }
 | 
						|
   MAX-ACCESS   read-only
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
        "This object hold the Alarm for this Entry. only Test that have can have alarms
 | 
						|
          use this field, other holds the Value notRelevant(1) "
 | 
						|
   ::= { rlPhyTestGetEntry 5 }
 | 
						|
 | 
						|
rlPhyTestGetTimeStamp   OBJECT-TYPE
 | 
						|
   SYNTAX  DisplayString (SIZE(1..32))
 | 
						|
   MAX-ACCESS   read-only
 | 
						|
   STATUS       current
 | 
						|
   DESCRIPTION
 | 
						|
        "The time in string (formated DD-MMM-YYYY HH:MM:SS e.g
 | 
						|
         14-Apr-2002 10:33:31)"
 | 
						|
    ::= { rlPhyTestGetEntry 6 }
 | 
						|
 | 
						|
END
 |