mibs/MIBS/dasan/SLE-MPLS-TP-LPS-MIB

870 lines
24 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
--
-- sle-mpls-tp-lps-mib.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
-- Tuesday, January 12, 2016 at 11:21:30
--
SLE-MPLS-TP-LPS-MIB DEFINITIONS ::= BEGIN
IMPORTS
sleMgmt
FROM DASAN-SMI
SleControlStatusType, SleControlRequestResultType
FROM SLE-TC-MIB
TimeTicks, Unsigned32, Gauge32, OBJECT-TYPE, MODULE-IDENTITY,
OBJECT-IDENTITY
FROM SNMPv2-SMI;
sleMplsTpLps MODULE-IDENTITY
LAST-UPDATED "201510070000Z" -- October 07, 2015 at 00:00 GMT
ORGANIZATION
"Multiprotocol Label Switching (MplsTp) Working Group"
CONTACT-INFO
"Gyerok Kwon
Dasan Networks
Email: grkwon@dasannetworks.com
Kantharaj B M
Dasan Networks
Email: kanth@dasannetworks.com
DongChel Shin (Chris)
Dasan Networks
Email: dchshin@dasannetworks.com
Comments about this document should be emailed
directly to the Dasan support email ID at
support@dasannetworks.com."
DESCRIPTION
"This management information module supports the
configuration and management of MplsTp TP linear
protection groups. "
REVISION "201207150000Z" -- July 15, 2012 at 00:00 GMT
DESCRIPTION
"MplsTp Protection Switching Group objects for LSP MEPs"
::= { sleMpls 18 }
--
-- Node definitions
--
sleMpls OBJECT-IDENTITY
STATUS current
DESCRIPTION
"SLE MplsTp."
::= { sleMgmt 16 }
sleMplsTpLpsCfg OBJECT IDENTIFIER ::= { sleMplsTpLps 1 }
sleMplsTpLpsCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleMplsTpLpsCfgInfoEntry
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This table lists the sleMplsTp linear protection groups that
have been configured on the system."
::= { sleMplsTpLpsCfg 1 }
sleMplsTpLpsCfgInfoEntry OBJECT-TYPE
SYNTAX SleMplsTpLpsCfgInfoEntry
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A conceptual row in the sleMplsTpLpsCfgInfoTable."
INDEX { sleMplsTpLpsCfgInfoGroupIndex }
::= { sleMplsTpLpsCfgInfoTable 1 }
SleMplsTpLpsCfgInfoEntry ::=
SEQUENCE {
sleMplsTpLpsCfgInfoGroupIndex
Unsigned32,
sleMplsTpLpsCfgInfoGroupName
OCTET STRING,
sleMplsTpLpsCfgInfoMode
INTEGER,
sleMplsTpLpsCfgInfoProtectionScheme
INTEGER,
sleMplsTpLpsCfgInfoRevertive
INTEGER,
sleMplsTpLpsCfgInfoWtr
Unsigned32,
sleMplsTpLpsCfgInfoContinualTxInterval
Unsigned32,
sleMplsTpLpsCfgInfoRapidTxInterval
Unsigned32,
sleMplsTpLpsCfgInfoSwitchOver
INTEGER,
sleMplsTpLpsCfgInfoLockOut
INTEGER,
sleMplsTpLpsCfgInfoHoldOffTimer
Unsigned32,
sleMplsTpLpsCfgInfoActivePath
INTEGER,
sleMplsTpLpsCfgInfoOperationState
INTEGER,
sleMplsTpLpsCfgInfoEventStatus
INTEGER
}
sleMplsTpLpsCfgInfoGroupIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for the conceptual row identifying a protection group."
::= { sleMplsTpLpsCfgInfoEntry 1 }
sleMplsTpLpsCfgInfoGroupName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Textual name represents the sleMplsTp tp protection group.
Each Protection Group is identified by a unique
protection group name. "
::= { sleMplsTpLpsCfgInfoEntry 2 }
sleMplsTpLpsCfgInfoMode OBJECT-TYPE
SYNTAX INTEGER
{
onePlusOne(1),
oneColonOne(2),
oneColonN(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The architectural mode of the Protection group. This can
either be 1+1, 1:1, 1:n.
1+1
In the 1+1 protection scheme, a fully dedicated
protection entity is allocated. Data traffic is copied
and fed at the source to both the working and the
protection entities. The traffic on the working and the
protection entities is transmitted simultaneously to
the sink of the protection domain, where selection
between the working and protection entities is performed
1:1
In the 1:1 scheme, a protection path is allocated to
protect against a defect, failure, or a degradation in a
working path. In normal conditions, data traffic is
transmitted over the working entity, while the
protection entity functions in the idle state. If there
is a defect on the working entity or a specific
administrative request, traffic is switched to the
protection entity.
1:n
In case of 1:n linear protection, one protection entity
is allocated to protect n working entities. The protection
entity might not have sufficient resources to protect all the
working entities that may be affected by fault conditions at a
specific time. In this case, in order to guaranteed
protection, the protection entity should support enough
capacity and bandwidth to protect any of the n working
entities."
DEFVAL { oneColonOne }
::= { sleMplsTpLpsCfgInfoEntry 3 }
sleMplsTpLpsCfgInfoProtectionScheme OBJECT-TYPE
SYNTAX INTEGER
{
bidirectional(1),
unidirectional(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object represents the operational scheme of
protection switching group. The protection scheme may
either be unidirectional or bidirectional.
bidirectional
In bidirectional protection scheme, both the directions
will be switched simultaneously even if the fault
applies to only one direction of the path.
unidirectional
In unidirectional protection scheme protection switching
will be performed independently for each direction of a
bidirectional transport path
This object may not be modified if the associated
sleMplsTpLpsCfgRowStatus object is equal to active(1). "
DEFVAL { bidirectional }
::= { sleMplsTpLpsCfgInfoEntry 4 }
sleMplsTpLpsCfgInfoRevertive OBJECT-TYPE
SYNTAX INTEGER
{
nonrevertive(1),
revertive(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the reversion mode of the Linear
Protection Switching group. The reversion mode of
protection mechanism may be either revertive or
non-revertive.
In non-revertive mode, after a service has been
recovered, traffic will be forwarded on the recovery
path revertive
In revertive mode, after a service has been
recovered, traffic will be redirected back onto the
original working path."
DEFVAL { nonrevertive }
::= { sleMplsTpLpsCfgInfoEntry 5 }
sleMplsTpLpsCfgInfoWtr OBJECT-TYPE
SYNTAX Unsigned32 (0..720)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object hold the Wait To Restore timer value in
seconds.
The WTR timer is used to delay reversion of PSC state
to Normal state when recovering from a failure
condition on the working path when the protection
domain is configured for revertive behavior
This object may not be modified if the associated
sleMplsTpLpsCfgRowStatus object is equal to active(1)."
DEFVAL { 300 }
::= { sleMplsTpLpsCfgInfoEntry 6 }
sleMplsTpLpsCfgInfoContinualTxInterval OBJECT-TYPE
SYNTAX Unsigned32 (1..20)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Continual Tx Time in Seconds. Represents the time
interval to send the continual LPS packet to the other
end based on the current state."
DEFVAL { 5 }
::= { sleMplsTpLpsCfgInfoEntry 7 }
sleMplsTpLpsCfgInfoRapidTxInterval OBJECT-TYPE
SYNTAX Unsigned32 (1000..20000)
UNITS "micro-seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Rapid Tx interval in micro-Seconds. Represents the time
interval to send the LPS packet to the other end, when
there is a change in state of Linear Protection domain due
to local input. The default value is 3.3 milli-seconds
which is 3300 micro-seconds"
DEFVAL { 3300 }
::= { sleMplsTpLpsCfgInfoEntry 8 }
sleMplsTpLpsCfgInfoSwitchOver OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
forced(1),
manual(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" this object used for switch the traffic to the back up path."
::= { sleMplsTpLpsCfgInfoEntry 9 }
sleMplsTpLpsCfgInfoLockOut OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"this is object is used for preventing the swith traffic by the protection path."
::= { sleMplsTpLpsCfgInfoEntry 10 }
sleMplsTpLpsCfgInfoHoldOffTimer OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" this object used for show the hold off timer."
::= { sleMplsTpLpsCfgInfoEntry 11 }
sleMplsTpLpsCfgInfoActivePath OBJECT-TYPE
SYNTAX INTEGER
{
primary(1),
backup(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object say which path is Active ."
::= { sleMplsTpLpsCfgInfoEntry 12 }
sleMplsTpLpsCfgInfoOperationState OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(0)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"this object says Operational Status of LPS. The LPS is between PE to PE."
DEFVAL { 0 }
::= { sleMplsTpLpsCfgInfoEntry 13 }
sleMplsTpLpsCfgInfoEventStatus OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
protection(2),
localForce(3),
localManual(4),
localSgfProtection(5),
localSgfWorking(6),
localWtr(7),
localLock(8),
localClrSfProtection(9),
localClrSfWorking(10),
localClrEvent(11),
remoteLock(12),
remoteForce(13),
remoteManual(14),
remoteSfProtect(15),
remoteSfWork(16),
remoteWtr(17),
remoteNoReq(18),
remoteNotRevert(19),
noRequest(20),
remoteSdWork(21),
remoteSdProtection(22),
remoteExesWork(23),
remoteExesProtect(24),
remoteRrReqWork(25),
remoteRrReqProtec(26),
remoteNoReqWork(27),
remoteNoReqProtection(28),
localSdProtection(29),
localClearSdProtection(30),
localSdWorking(31),
localClearSdWorking(32),
localExercise(33)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is object says EVENT Status of LPS protection ."
DEFVAL { 0 }
::= { sleMplsTpLpsCfgInfoEntry 14 }
sleMplsTpLpsCfgControl OBJECT IDENTIFIER ::= { sleMplsTpLpsCfg 2 }
sleMplsTpLpsCfgControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createSleMplsTpLpsCfgEntry(1),
deleteSleMplsTpLpsCfgEntry(2),
setSleMplsTpLpsCfgControProtectionScheme(3),
unsetSleMplsTpLpsCfgControProtectionScheme(4),
setSleMplsLpsTpCfgControlRevertive(5),
setSleMplsLpsTpCfgControlWaitToRestoreset(6),
unsetSleMplsTpLpsCfgControlWaitToRestoreset(7),
setSleMplsLpsTpCfgControlContinualTxInterval(8),
unsetSleMplsTpLpsCfgControlContinualTxInterval(9),
setSleMplsLpsTpCfgControlRapidTxInterval(10),
unsetSleMplsTpLpsCfgControlRapidTxInterval(11),
setSleMplsLpsTpCfgControlSwitchover(12),
unsetSleMplsTpLpsCfgControlSwitchover(13),
setSleMplsTpLpsCfgControlLockOut(14),
unsetSleMplsTpLpsTpCfgControlLockOut(15),
setSleMplsTpLpsCfgControlHoldOffTimer(16),
unSetSleMplsTpLpsCfgControlHoldOffTimer(17)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"the configuration commands, and user can configure functions
via setting this entry as proper value."
::= { sleMplsTpLpsCfgControl 1 }
sleMplsTpLpsCfgControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"status of user command. User have to check this value as
.busy. or .idle. before do setRequest."
::= { sleMplsTpLpsCfgControl 2 }
sleMplsTpLpsCfgControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"the wait-time until setRequest end. In case of short-time command, this value is 0"
::= { sleMplsTpLpsCfgControl 3 }
sleMplsTpLpsCfgControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"the time stamp of the last command. (don.t care)"
::= { sleMplsTpLpsCfgControl 4 }
sleMplsTpLpsCfgControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Result of the last command."
::= { sleMplsTpLpsCfgControl 5 }
sleMplsTpLpsCfgControlGroupName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Textual name represents the sleMplsTp tp protection group.
Each Protection Group is identified by a unique
protection group name. "
::= { sleMplsTpLpsCfgControl 6 }
sleMplsTpLpsCfgControlMode OBJECT-TYPE
SYNTAX INTEGER
{
onePlusOne(1),
oneColonOne(2),
oneColonN(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The architectural mode of the Protection group. This can
either be 1+1, 1:1, 1:n.
1+1
In the 1+1 protection scheme, a fully dedicated
protection entity is allocated. Data traffic is copied
and fed at the source to both the working and the
protection entities. The traffic on the working and the
protection entities is transmitted simultaneously to
the sink of the protection domain, where selection
between the working and protection entities is performed
1:1
In the 1:1 scheme, a protection path is allocated to
protect against a defect, failure, or a degradation in a
working path. In normal conditions, data traffic is
transmitted over the working entity, while the
protection entity functions in the idle state. If there
is a defect on the working entity or a specific
administrative request, traffic is switched to the
protection entity.
1:n
In case of 1:n linear protection, one protection entity
is allocated to protect n working entities. The protection
entity might not have sufficient resources to protect all the
working entities that may be affected by fault conditions at a
specific time. In this case, in order to guaranteed
protection, the protection entity should support enough
capacity and bandwidth to protect any of the n working
entities."
DEFVAL { oneColonOne }
::= { sleMplsTpLpsCfgControl 7 }
sleMplsTpLpsCfgControlProtectionScheme OBJECT-TYPE
SYNTAX INTEGER
{
bidirectional(1),
unidirectional(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object represents the operational scheme of
protection switching group. The protection scheme may
either be unidirectional or bidirectional.
bidirectional
In bidirectional protection scheme, both the directions
will be switched simultaneously even if the fault
applies to only one direction of the path.
unidirectional
In unidirectional protection scheme protection switching
will be performed independently for each direction of a
bidirectional transport path
This object may not be modified if the associated
sleMplsTpLpsCfgControlRowStatus object is equal to active(1). "
DEFVAL { bidirectional }
::= { sleMplsTpLpsCfgControl 8 }
sleMplsTpLpsCfgControlRevertive OBJECT-TYPE
SYNTAX INTEGER
{
nonrevertive(1),
revertive(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the reversion mode of the Linear
Protection Switching group. The reversion mode of
protection mechanism may be either revertive or
non-revertive.
nonrevertive
In non-revertive mode, after a service has been
recovered, traffic will be forwarded on the recovery
path
revertive
In revertive mode, after a service has been
recovered, traffic will be redirected back onto the
original working path."
DEFVAL { nonrevertive }
::= { sleMplsTpLpsCfgControl 9 }
sleMplsTpLpsCfgControlWtr OBJECT-TYPE
SYNTAX Unsigned32 (0..720)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object hold the Wait To Restore timer value in
seconds.
The WTR timer is used to delay reversion of PSC state
to Normal state when recovering from a failure
condition on the working path when the protection
domain is configured for revertive behavior
This object may not be modified if the associated
sleMplsTpLpsCfgControlRowStatus object is equal to active(1)."
DEFVAL { 300 }
::= { sleMplsTpLpsCfgControl 10 }
sleMplsTpLpsCfgControlContinualTxInterval OBJECT-TYPE
SYNTAX Unsigned32 (1..20)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Continual Tx Time in Seconds. Represents the time
interval to send the continual LPS packet to the other
end based on the current state."
DEFVAL { 5 }
::= { sleMplsTpLpsCfgControl 11 }
sleMplsTpLpsCfgControlRapidTxInterval OBJECT-TYPE
SYNTAX Unsigned32 (1000)
UNITS "micro-seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Rapid Tx interval in micro-Seconds. Represents the time
interval to send the LPS packet to the other end, when
there is a change in state of Linear Protection domain due
to local input. The default value is 3.3 milli-seconds
which is 3300 micro-seconds"
DEFVAL { 3300 }
::= { sleMplsTpLpsCfgControl 12 }
sleMplsTpLpsCfgControlswitchOver OBJECT-TYPE
SYNTAX INTEGER
{
force(1),
manual(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" this object used for switch the traffic to the back up path."
::= { sleMplsTpLpsCfgControl 13 }
sleMplsTpLpsCfgControlLockOut OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"this is object is used for preventing the swith traffic by the protection path."
::= { sleMplsTpLpsCfgControl 14 }
sleMplsTpLpsCfgControlHoldOffTimer OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to set the holdofftimer "
::= { sleMplsTpLpsCfgControl 15 }
sleMplsTpLpsMeCfg OBJECT IDENTIFIER ::= { sleMplsTpLps 2 }
sleMplsTpLpsMeCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleMplsTpLpsMeCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists Maintenance Association that have been
configured in Protection groups."
::= { sleMplsTpLpsMeCfg 1 }
sleMplsTpLpsMeCfgInfoEntry OBJECT-TYPE
SYNTAX SleMplsTpLpsMeCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the sleMplsTpLpsMeCfgInfoTable."
INDEX { sleMplsTpLpsMeCfgInfoMeIndex, sleMplsTpLpsMeCfgInfoMPId, sleMplsTpLspMeCfgInfoGroupIndex, sleMplsTpLpsMeCfgInfoMegIndex }
::= { sleMplsTpLpsMeCfgInfoTable 1 }
SleMplsTpLpsMeCfgInfoEntry ::=
SEQUENCE {
sleMplsTpLpsMeCfgInfoMegIndex
Unsigned32,
sleMplsTpLpsMeCfgInfoMeIndex
Unsigned32,
sleMplsTpLpsMeCfgInfoMPId
Unsigned32,
sleMplsTpLspMeCfgInfoGroupIndex
Unsigned32,
sleMplsTpLpsMeCfgInfoState
INTEGER
}
sleMplsTpLpsMeCfgInfoMegIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies a maintenance entity index within
a MEG."
::= { sleMplsTpLpsMeCfgInfoEntry 1 }
sleMplsTpLpsMeCfgInfoMeIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object denotes the ME name, each
Maintenance Entity has unique name within MEG."
::= { sleMplsTpLpsMeCfgInfoEntry 2 }
sleMplsTpLpsMeCfgInfoMPId OBJECT-TYPE
SYNTAX Unsigned32 (1..8191)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the maintenance point index, used to create
multiple MEPs in a node of single ME. The value of this
object can be MEP index or MIP index. Managers should
obtain new values for row creation in this table by reading
mplsOamIdMeMpIndexNext."
::= { sleMplsTpLpsMeCfgInfoEntry 3 }
sleMplsTpLspMeCfgInfoGroupIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Textual name represents the sleMplsTp tp protection group.
Each Protection Group is identified by a unique
protection group name. "
::= { sleMplsTpLpsMeCfgInfoEntry 4 }
sleMplsTpLpsMeCfgInfoState OBJECT-TYPE
SYNTAX INTEGER
{
primary(1),
backup(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the operational state of the ME
as either primary or backup"
::= { sleMplsTpLpsMeCfgInfoEntry 5 }
sleMplsTpLpsMeCfgControl OBJECT IDENTIFIER ::= { sleMplsTpLpsMeCfg 2 }
sleMplsTpLpsMeCfgControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createSleMplsTpLpsMeConfigEntry(1),
deleteSleMplsTpLpsMeConfigEntry(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"the configuration commands, and user can configure functions via setting
this entry as proper value."
::= { sleMplsTpLpsMeCfgControl 1 }
sleMplsTpLpsMeCfgControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"status of user command. User have to check this value as
.busy. or .idle. before do setRequest."
::= { sleMplsTpLpsMeCfgControl 2 }
sleMplsTpLpsMeCfgControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"the wait-time until setRequest end. In case of short-time command, this value is 0"
::= { sleMplsTpLpsMeCfgControl 3 }
sleMplsTpLpsMeCfgControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"the time stamp of the last command. (don.t care)"
::= { sleMplsTpLpsMeCfgControl 4 }
sleMplsTpLpsMeCfgControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Result of the last command."
::= { sleMplsTpLpsMeCfgControl 5 }
sleMplsTpLpsMeCfgControlMegName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Uniquely identifies a maintenance entity index within
a MEG"
::= { sleMplsTpLpsMeCfgControl 6 }
sleMplsTpLpsMeCfgControlMeName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object denotes the ME name, each
Maintenance Entity has unique name within MEG."
::= { sleMplsTpLpsMeCfgControl 7 }
sleMplsTpLpsMeCfgControlMpId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION " "
::= { sleMplsTpLpsMeCfgControl 8 }
sleMplsTpLpsMeCfgControlGroupName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object holds the Protection group index wherein
this ME included in. If this ME is not part of a protection
group this value is set to 0. "
::= { sleMplsTpLpsMeCfgControl 9 }
sleMplsTpLpsMeCfgControlState OBJECT-TYPE
SYNTAX INTEGER
{
primary(1),
backup(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the operational state of the ME
as either primary or backup"
::= { sleMplsTpLpsMeCfgControl 10 }
END
--
-- sle-mpls-tp-lps-mib.mib
--