mibs/MIBS/dell/F10-S-SERIES-CHASSIS-MIB

1451 lines
48 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
F10-S-SERIES-CHASSIS-MIB DEFINITIONS ::= BEGIN
-- Force10 Networks, Inc.
-- 390 Holger Way
-- San Jose, CA 95134
-- This module provides authoritative definitions for S-series
-- Force10 enterprise Chassis MIB.
--
-- This module will be extended, as needed.
--
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Gauge32, Counter32, Integer32, Unsigned32,
TimeTicks, NOTIFICATION-TYPE
FROM SNMPv2-SMI
DateAndTime, DisplayString,
MacAddress, RowStatus, TEXTUAL-CONVENTION
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
f10Mgmt
FROM FORCE10-SMI
chAlarmVarInteger, chAlarmVarString,
chAlarmVarSlot, chAlarmVarPort
FROM F10-CHASSIS-MIB
F10SwDate, F10ChassisType, F10ProcessorModuleType,
F10MfgDate, F10HundredthdB, F10SSeriesPortType
FROM FORCE10-TC;
f10SSerChassisMib MODULE-IDENTITY
LAST-UPDATED "200710031200Z" -- Oct 3, 2007 12:00:00 GMT
ORGANIZATION
"Force10 Networks, Inc."
CONTACT-INFO
"Force10 Networks, Inc.
350 Holger Way
San Jose, CA 95134 USA
Phone: +1 (408) 571 3500
Fax: +1 (408) 571 3550
Email: support@force10networks.com"
DESCRIPTION
"Force10 S-Series Enterprise Chassis MIB. "
REVISION "200710031200Z"
DESCRIPTION
"Initial version of this mib."
::= { f10Mgmt 10 }
-- ### Groups ###
f10SSerChassisObject OBJECT IDENTIFIER ::={ f10SSerChassisMib 1 }
chObjects OBJECT IDENTIFIER ::={ f10SSerChassisObject 1 }
chSysObjects OBJECT IDENTIFIER ::={ f10SSerChassisObject 2 }
chAlarmObjects OBJECT IDENTIFIER ::={ f10SSerChassisObject 4 }
-- ### Textual Convention
CodeType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "x"
STATUS current
DESCRIPTION
"The code type value for a given unit,
displayed in hexadecimal."
SYNTAX Unsigned32
UnitType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "x"
STATUS current
DESCRIPTION
"The unit type value for a given unit,
displayed in hexadecimal."
SYNTAX Unsigned32
-- ### Chassis Information
chNumStackUnits OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of stack units configured
on the chassis."
::= { chObjects 1 }
chNumMaxStackableUnits OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum allowed Unit Number
configurable on the chassis."
::= { chObjects 2 }
chStackUnitIndexNext OBJECT-TYPE
SYNTAX Integer32 (0|1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the next appropriate value to
be used for chStackUnitIndex when creating
entries in the chStackUnitTable. The value 0
indicates that no unassigned entries are available.
To obtain the chStackUnitIndexNext value for a new entry,
the manager must first issue a management protocol
retrieval operation to obtain the current value of
this object. The agent should modify the value to
reflect the next unassigned number after each
retrieval operation. After a manager retrieves a value
the agent will determine when this index value will be
made available for reuse.
Note that this object is not the unit number assigned by
the management unit."
::= { chObjects 3 }
-- ### Chassis System ###
-- ## SwitchType Table
-- The S-series chassis has a list of supported switch
-- types to configure a unit.
-- The switchType table contains the information of
-- supported switch types.
chSwitchTypeTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChSwitchTypeEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A list of supported switch types.
"
::= { chSysObjects 1 }
chSwitchTypeEntry OBJECT-TYPE
SYNTAX ChSwitchTypeEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A list of supported switch types entries."
INDEX { chSwitchTypeSID }
::= { chSwitchTypeTable 1 }
ChSwitchTypeEntry ::=
SEQUENCE {
chSwitchTypeSID Integer32,
chSwitchTypeModelID DisplayString,
chSwitchTypeCodeType CodeType,
chSwitchTypeMgmtPreference Integer32
}
chSwitchTypeSID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The unique switch type index (SID)."
::= { chSwitchTypeEntry 1 }
chSwitchTypeModelID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The pre-configured model ID for this swich type."
::= { chSwitchTypeEntry 2 }
chSwitchTypeCodeType OBJECT-TYPE
SYNTAX CodeType
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The code type of this switch type."
::= { chSwitchTypeEntry 3 }
chSwitchTypeMgmtPreference OBJECT-TYPE
SYNTAX Integer32 (0|1..15)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"indicates the default prefernce value for
the management unit. A value of 0 indicates a disabled
or unassigned preference."
::= { chSwitchTypeEntry 4 }
-- ## StackUnit Table
-- The S-series chassis is a single virtual system to
-- have the stackable units as virtual slots.
-- In the chassis, there can be multiple physical units
-- stacked together.
-- The StackUnit table contains the management information
-- of each stacked unit in the chassis.
chStackUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChStackUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of stack units configured in the chassis.
The StackUnit table contains the management
information of each stacked unit in the chassis.
"
::= { chSysObjects 2 }
chStackUnitEntry OBJECT-TYPE
SYNTAX ChStackUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of units entries containing information
for each stacked unit."
INDEX { chStackUnitIndex }
::= { chStackUnitTable 1 }
ChStackUnitEntry ::=
SEQUENCE {
chStackUnitIndex Integer32,
chStackUnitNumber Integer32,
chStackUnitSID Integer32,
chStackUnitMgmtStatus INTEGER,
chStackUnitHwMgmtPreference INTEGER,
chStackUnitAdmMgmtPreference Integer32,
chStackUnitModelID DisplayString,
chStackUnitStatus INTEGER,
chStackUnitDescription DisplayString,
chStackUnitCodeVersion DisplayString,
chStackUnitCodeVersionInFlash DisplayString,
chStackUnitSerialNumber DisplayString,
chStackUnitUpTime TimeTicks,
chStackUnitTemp Gauge32,
chStackUnitType UnitType,
chStackUnitSysType F10ChassisType,
chStackUnitVendorId DisplayString,
chStackUnitMfgDate F10MfgDate,
chStackUnitMacAddress MacAddress,
chStackUnitPartNum DisplayString,
chStackUnitProductRev DisplayString,
chStackUnitProductOrder DisplayString,
chStackUnitCountryCode OCTET STRING,
chStackUnitNum10GigEtherPorts Integer32,
chStackUnitNumGigEtherPorts Integer32,
chStackUnitNumFastEtherPorts Integer32,
chStackUnitNumFanTrays Integer32,
chStackUnitNumPowerSupplies Integer32,
chStackUnitNumPluggableModules Integer32,
chStackUnitRowStatus RowStatus
}
chStackUnitIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The unique index for this entry.
Refer to the object chStackUnitIndexNext."
::= { chStackUnitEntry 1 }
chStackUnitNumber OBJECT-TYPE
SYNTAX Integer32 (0|1..8)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The unit number associated with this unit.
The unit number can be manually assigned to stack members.
Note that the unit number assignement is based on
the following factors:
- if the unit number is requested here, but another unit
already uses that number, the unit changes its configured
unit number to the lowest unassigned unit number.
- if the unit number is 0, i.e. unassigned, then the unit sets
its configured unit number to the lowest unassigned unit number.
- if the unit number is configured and no other device uses
the unit number, then the unit starts using the configured
unit number.
- if a unit detects that the maximum number of units already
exist, the unit sets its unit number to 0, i.e. unassigned,
and stays in the Initialization state."
::= { chStackUnitEntry 2 }
chStackUnitSID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"The index of the chSwitchTypeTable which this unit
is associated with."
::= { chStackUnitEntry 3 }
chStackUnitMgmtStatus OBJECT-TYPE
SYNTAX INTEGER {
mgmtUnit(1),
standbyUnit(2),
stackUnit(3),
unassigned(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether the unit is a Management Unit,
a Stack Unit, or unassigned.
Setting this object to mgmtUnit(1) initiates transfer of the
management functionality to the specified stack unit.
Object values stackUnit(2) and unassigned(3) cannot be set."
::= { chStackUnitEntry 4 }
chStackUnitHwMgmtPreference OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
unsassigned(1),
assigned(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"indicates whether the unit is capable of becoming a
management unit. if it is unsigned, this unit can be a management
unit."
::= { chStackUnitEntry 5 }
chStackUnitAdmMgmtPreference OBJECT-TYPE
SYNTAX Integer32 (0|1..15)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"indicates how likely this unit is to be chosen as
the management unit. A value of 0 indicates a disabled
or unassigned preference."
::= { chStackUnitEntry 6 }
chStackUnitModelID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The plugged-in model ID for this unit."
::= { chStackUnitEntry 7 }
chStackUnitStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
unsupported(2),
codeMismatch(3), -- version mismatch
configMismatch(4), -- type mismatch
unitDown(5), -- hardware problem
notPresent(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of this unit."
::= { chStackUnitEntry 8 }
chStackUnitDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The description of this unit."
::= { chStackUnitEntry 9 }
chStackUnitCodeVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current code version of this unit."
::= { chStackUnitEntry 10 }
chStackUnitCodeVersionInFlash OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Code version of this unit's flash."
::= { chStackUnitEntry 11 }
chStackUnitSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit's serial number."
::= { chStackUnitEntry 12 }
chStackUnitUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system up time of the unit."
::= { chStackUnitEntry 13 }
chStackUnitTemp OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature of the unit."
::= { chStackUnitEntry 14 }
chStackUnitType OBJECT-TYPE
SYNTAX UnitType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Unit Type identifier for this unit."
::= { chStackUnitEntry 15 }
chStackUnitSysType OBJECT-TYPE
SYNTAX F10ChassisType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Force10 system type for this unit."
::= { chStackUnitEntry 16 }
chStackUnitVendorId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor id that manufactured this unit."
::= { chStackUnitEntry 17 }
chStackUnitMfgDate OBJECT-TYPE
SYNTAX F10MfgDate
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date the unit is manufactured."
::= { chStackUnitEntry 18 }
chStackUnitMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 6-octet MAC Address assigned
to this unit."
::= { chStackUnitEntry 19 }
chStackUnitPartNum OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit part number"
::= { chStackUnitEntry 20 }
chStackUnitProductRev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit manufacturer's product
revision"
::= { chStackUnitEntry 21 }
chStackUnitProductOrder OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The product order number for this unit."
::= { chStackUnitEntry 22 }
chStackUnitCountryCode OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit manufacturer's country
code"
::= { chStackUnitEntry 23 }
chStackUnitNum10GigEtherPorts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of 10G Ethernet/802.3 interfaces
in this unit."
::= { chStackUnitEntry 24 }
chStackUnitNumGigEtherPorts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of 1G Ethernet/802.3 interfaces
in this unit."
::= { chStackUnitEntry 25 }
chStackUnitNumFastEtherPorts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of 10/100 Ethernet/802.3 interfaces
in this unit."
::= { chStackUnitEntry 26 }
chStackUnitNumFanTrays OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of fan trays
on the unit."
::= { chStackUnitEntry 27 }
chStackUnitNumPowerSupplies OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of power supply
in the unit."
::= { chStackUnitEntry 28 }
chStackUnitNumPluggableModules OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pluggable modules
in the stack."
::= { chStackUnitEntry 29 }
chStackUnitRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation of new instances requires the object
chStackUnitIndexNext to be retreived to create
an entry.
active(1) - This instance is active.
createAndGo(4) - Creates a new instance.
destroy(6) - Removes this instance."
::= { chStackUnitEntry 30 }
-- ### Power Supply Table
chSysPowerSupplyTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChSysPowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of power supply resident
in the S-series chassis."
::= { chSysObjects 3 }
chSysPowerSupplyEntry OBJECT-TYPE
SYNTAX ChSysPowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A power supply entry containing objects for a
particular power supply."
INDEX { chStackUnitNumber,
chSysPowerSupplyIndex }
::= { chSysPowerSupplyTable 1 }
ChSysPowerSupplyEntry ::=
SEQUENCE {
chSysPowerSupplyIndex Integer32,
chSysPowerSupplyOperStatus INTEGER,
chSysPowerSupplyType INTEGER
}
chSysPowerSupplyIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unique index of the power supply."
::= { chSysPowerSupplyEntry 1 }
chSysPowerSupplyOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the power supply."
::= { chSysPowerSupplyEntry 2 }
chSysPowerSupplyType OBJECT-TYPE
SYNTAX INTEGER {
ac(1),
dc(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the power supply."
::= { chSysPowerSupplyEntry 3 }
-- ## Fan Tray Table
chSysFanTrayTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChSysFanTrayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of fan tray resident in the S-series chassis."
::= { chSysObjects 4 }
chSysFanTrayEntry OBJECT-TYPE
SYNTAX ChSysFanTrayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A fan entry containing objects for a
particular fan tray."
INDEX { chStackUnitNumber,
chSysFanTrayIndex }
::= { chSysFanTrayTable 1 }
ChSysFanTrayEntry ::=
SEQUENCE {
chSysFanTrayIndex Integer32,
chSysFanTrayOperStatus INTEGER
}
chSysFanTrayIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unique index of the fan tray."
::= { chSysFanTrayEntry 1 }
chSysFanTrayOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the fan tray."
::= { chSysFanTrayEntry 2 }
-- ## Port Table
chSysPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChSysPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of ports in the S-series chassis."
::= { chSysObjects 5 }
chSysPortEntry OBJECT-TYPE
SYNTAX ChSysPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A port entry containing objects for a
particular port."
INDEX { chStackUnitNumber,
chSysPortIndex }
::= { chSysPortTable 1 }
ChSysPortEntry ::=
SEQUENCE {
chSysPortIndex Integer32,
chSysPortType F10SSeriesPortType,
chSysPortAdminStatus INTEGER,
chSysPortOperStatus INTEGER,
chSysPortIfIndex Integer32,
chSysPortXfpRecvPower F10HundredthdB
}
chSysPortIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique index for each slot within the unit.
"
::= { chSysPortEntry 1 }
chSysPortType OBJECT-TYPE
SYNTAX F10SSeriesPortType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of port in the unit."
::= { chSysPortEntry 2 }
chSysPortAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The admin status of the card.
The port admin status is Up if
the user has configured it to be up
otherwise, the admin status is Down."
::= { chSysPortEntry 3 }
chSysPortOperStatus OBJECT-TYPE
SYNTAX INTEGER {
ready(1),
portDown(2),
portProblem(3),
cardProblem(4),
cardDown(5),
notPresent(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational status provides further
condition of the card.
If the chSysPortAdminStatus is 'up', the
valid state is
'ready' - the card is present and
ready and the chSysPortAdminStatus
status is 'up'.
'portDown' - the port is down or not enabled.
'portProblem' - port hardware problems.
'cardProblem' - not used. Same as cardDown.
'cardDown' - the card is downed.
'notPresent' - the card is not present."
::= { chSysPortEntry 4 }
chSysPortIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ifIndex in the Interface Mib.
This index can link to the ifEntry to get
this interface/port information"
::= { chSysPortEntry 5 }
chSysPortXfpRecvPower OBJECT-TYPE
SYNTAX F10HundredthdB
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
The power signal strength (dB) received for
10G Ethernet/802.3 interface.
This object is applied to 10Gig port only.
"
::= { chSysPortEntry 6 }
-- ## Stack Port Table
chSysStackPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChSysStackPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of stack ports in the S-series chassis."
::= { chSysObjects 6 }
chSysStackPortEntry OBJECT-TYPE
SYNTAX ChSysStackPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A stack port entry containing objects for a
particular stack port."
INDEX { chStackUnitNumber,
chSysStackPortIndex }
::= { chSysStackPortTable 1 }
ChSysStackPortEntry ::=
SEQUENCE {
chSysStackPortIndex Integer32,
chSysStackPortConfiguredMode INTEGER,
chSysStackPortRunningMode INTEGER,
chSysStackPortLinkStatus INTEGER,
chSysStackPortLinkSpeed Gauge32,
chSysStackPortRxDataRate Counter32,
chSysStackPortRxErrorRate Counter32,
chSysStackPortRxTotalErrors Counter32,
chSysStackPortTxDataRate Counter32,
chSysStackPortTxErrorRate Counter32,
chSysStackPortTxTotalErrors Counter32
}
chSysStackPortIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index for each stack port within the unit.
1 - stack port A,
2 - stack port B
"
::= { chSysStackPortEntry 1 }
chSysStackPortConfiguredMode OBJECT-TYPE
SYNTAX INTEGER {
stack(1),
ethernet(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Configured mode of the Stack Port. Changes to this
value happen only after a reset of the unit."
::= { chSysStackPortEntry 2 }
chSysStackPortRunningMode OBJECT-TYPE
SYNTAX INTEGER {
stack(1),
ethernet(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operational mode of the Stack Port."
::= { chSysStackPortEntry 3 }
chSysStackPortLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link status of the Stack Port. Ports in ethernet
mode will return a status of down(2)."
::= { chSysStackPortEntry 4 }
chSysStackPortLinkSpeed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Speed of the Stack Port measured in Gb/s. Ports
in ethernet mode will return a speed of 0."
::= { chSysStackPortEntry 5 }
chSysStackPortRxDataRate OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received Data rate on the stacking port.
Measured in Mb/s.
Ports in ethernet mode will return 0."
::= { chSysStackPortEntry 6 }
chSysStackPortRxErrorRate OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received error rate on the stack port.
Measured in Errors per Second.
Ports in ethernet mode will return 0."
::= { chSysStackPortEntry 7 }
chSysStackPortRxTotalErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received number of errors since boot.
The counter may wrap. Ports in ethernet mode
will return 0."
::= { chSysStackPortEntry 8 }
chSysStackPortTxDataRate OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted Data rate on the stacking port.
Measured in Mb/s.
Ports in ethernet mode will return 0."
::= { chSysStackPortEntry 9 }
chSysStackPortTxErrorRate OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted error rate on the stack port.
Measured in Errors per Second.
Ports in ethernet mode will return 0."
::= { chSysStackPortEntry 10 }
chSysStackPortTxTotalErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted number of errors since boot.
The counter may wrap. Ports in ethernet mode
will return 0."
::= { chSysStackPortEntry 11 }
-- ## Processor Table
-- Each stack unit has a single processor.
-- The Processor table contains information on the
-- processor and the memory.
chSysProcessorTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChSysProcessorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Processors resident in the S-series chassis."
::= { chSysObjects 7 }
chSysProcessorEntry OBJECT-TYPE
SYNTAX ChSysProcessorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Processor entries."
INDEX { chStackUnitNumber }
::= { chSysProcessorTable 1 }
ChSysProcessorEntry ::=
SEQUENCE {
chSysProcessorModule F10ProcessorModuleType,
chSysProcessorUpTime TimeTicks,
chSysProcessorNvramSize Integer32,
chSysProcessorMemSize Integer32
}
chSysProcessorModule OBJECT-TYPE
SYNTAX F10ProcessorModuleType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of module running on the Processor."
::= { chSysProcessorEntry 1 }
chSysProcessorUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SysUpTime for this Processor."
::= { chSysProcessorEntry 2 }
chSysProcessorNvramSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Non-volatile RAM in Kbytes."
::= { chSysProcessorEntry 3 }
chSysProcessorMemSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The size of the RAM in Mb."
::= { chSysProcessorEntry 4 }
-- ## Software Module Table
chSysSwModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChSysSwModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of software version information in
a processor."
::= { chSysObjects 8 }
chSysSwModuleEntry OBJECT-TYPE
SYNTAX ChSysSwModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A software module entry containing version
number information for a particular processor."
INDEX { chStackUnitNumber }
::= { chSysSwModuleTable 1 }
ChSysSwModuleEntry ::=
SEQUENCE {
chSysSwRuntimeImgVersion DisplayString,
chSysSwRuntimeImgDate F10SwDate,
chSysSwCurrentBootImgVersion DisplayString,
chSysSwCurrentBootImgDate DateAndTime,
chSysSwCurrentBootImgStatus INTEGER,
chSysSwBackupBootImgVersion DisplayString,
chSysSwBackupBootImgDate DateAndTime,
chSysSwBackupBootImgStatus INTEGER,
chSysSwNextRebootImage INTEGER,
chSysSwCurrentBootImage INTEGER
}
chSysSwRuntimeImgVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the software
module version that is currently
running on the processor.
The software release version is in
the format as follow:
<major version>.<minor version>.<minor
version>......
'1.1' indicate major version of 1 and
minor release of 1."
::= { chSysSwModuleEntry 1 }
chSysSwRuntimeImgDate OBJECT-TYPE
SYNTAX F10SwDate
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The release date of this software
module."
::= { chSysSwModuleEntry 2 }
chSysSwCurrentBootImgVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The software release version is in
the format as follow:
<major version>.<minor version>.<minor
version>......
'1.1' indicate major version of 1 and
minor release of 1."
::= { chSysSwModuleEntry 3 }
chSysSwCurrentBootImgDate OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The release date of this software module
If the CPU is reset, the software module
running date (chSysSwModuleRunningDate)
will change to this current date."
::= { chSysSwModuleEntry 4 }
chSysSwCurrentBootImgStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
failed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fill this in later"
::= { chSysSwModuleEntry 5 }
chSysSwBackupBootImgVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The software release version is in
the format as follow:
<major version>.<minor version>.<minor
version>......
'1.1' indicate major version of 1 and
minor release of 1."
::= { chSysSwModuleEntry 6 }
chSysSwBackupBootImgDate OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The backup boot image released date."
::= { chSysSwModuleEntry 7 }
chSysSwBackupBootImgStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
failed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the backup boot image."
::= { chSysSwModuleEntry 8 }
chSysSwNextRebootImage OBJECT-TYPE
SYNTAX INTEGER {
bootImage-A(1),
bootImage-B(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The boot flash image selection. When the
chassis is rebooted, this is the boot
image to use."
::= { chSysSwModuleEntry 9 }
chSysSwCurrentBootImage OBJECT-TYPE
SYNTAX INTEGER {
bootImage-A(1),
bootImage-B(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current boot image. This is the boot image described by the
chSysSwCurrentBootImgVersion, chSysSwCurrentBootImgDate, and
chSysSwCurrentBootImgStatus objects.
"
::= { chSysSwModuleEntry 10 }
-- ## Stack Unit CPU and Memory Utilization
chStackUnitUtilTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChStackUnitUtilEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table listing the cpu and memory utilization
in the stack unit."
::= { chSysObjects 9 }
chStackUnitUtilEntry OBJECT-TYPE
SYNTAX ChStackUnitUtilEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in each processor cpu and mmory utilization"
INDEX { chStackUnitNumber }
::= { chStackUnitUtilTable 1 }
ChStackUnitUtilEntry ::=
SEQUENCE {
chStackUnitCpuType F10ProcessorModuleType,
chStackUnitCpuUtil5Sec Gauge32,
chStackUnitCpuUtil1Min Gauge32,
chStackUnitCpuUtil5Min Gauge32,
chStackUnitMemUsageUtil Gauge32
}
chStackUnitCpuType OBJECT-TYPE
SYNTAX F10ProcessorModuleType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of module running on the Processor."
::= { chStackUnitUtilEntry 1 }
chStackUnitCpuUtil5Sec OBJECT-TYPE
SYNTAX Gauge32(0..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CPU utilization in percentage for last 5 seconds."
::= { chStackUnitUtilEntry 2 }
chStackUnitCpuUtil1Min OBJECT-TYPE
SYNTAX Gauge32(0..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CPU utilization in percentage for last 1 minute."
::= { chStackUnitUtilEntry 3 }
chStackUnitCpuUtil5Min OBJECT-TYPE
SYNTAX Gauge32(0..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CPU utilization in percentage for last 5 minutes."
::= { chStackUnitUtilEntry 4 }
chStackUnitMemUsageUtil OBJECT-TYPE
SYNTAX Gauge32(0..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total memory usage in percentage."
::= { chStackUnitUtilEntry 5 }
--
-- ## Notifications
--
chAlarmMibNotifications OBJECT IDENTIFIER ::= { chAlarmObjects 0 }
--
-- TRAPS
--
chAlarmStackUnitDown NOTIFICATION-TYPE
OBJECTS { chAlarmVarInteger,
chAlarmVarString,
chAlarmVarSlot,
chAlarmVarPort
}
STATUS current
DESCRIPTION
"The driver/agent generate this trap when a
stack unit operational status is down."
::= { chAlarmMibNotifications 1 }
chAlarmStackUnitUp NOTIFICATION-TYPE
OBJECTS { chAlarmVarInteger,
chAlarmVarString,
chAlarmVarSlot,
chAlarmVarPort
}
STATUS current
DESCRIPTION
"The driver/agent generate this trap when a
stack unit operational status is up."
::= { chAlarmMibNotifications 2 }
chAlarmStackUnitReset NOTIFICATION-TYPE
OBJECTS { chAlarmVarInteger,
chAlarmVarString,
chAlarmVarSlot,
chAlarmVarPort
}
STATUS current
DESCRIPTION
"The driver/agent generate this trap when a
stack unit is reset."
::= { chAlarmMibNotifications 3 }
chAlarmStackUnitOffline NOTIFICATION-TYPE
OBJECTS { chAlarmVarInteger,
chAlarmVarString,
chAlarmVarSlot,
chAlarmVarPort
}
STATUS current
DESCRIPTION
"The driver/agent generate this trap when a
stack unit is set to offline."
::= { chAlarmMibNotifications 4 }
chAlarmStackUnitCodeMismatch NOTIFICATION-TYPE
OBJECTS { chAlarmVarInteger,
chAlarmVarString,
chAlarmVarSlot,
chAlarmVarPort
}
STATUS current
DESCRIPTION
"The driver/agent generate this trap when a
stack unit is not the same code as a management
stack."
::= { chAlarmMibNotifications 5 }
chAlarmStackPortLinkUp NOTIFICATION-TYPE
OBJECTS { chAlarmVarInteger,
chAlarmVarString,
chAlarmVarSlot,
chAlarmVarPort
}
STATUS current
DESCRIPTION
"The driver/agent generate this trap when a
stack port is connected to annother stack member."
::= { chAlarmMibNotifications 6 }
chAlarmStackPortLinkDown NOTIFICATION-TYPE
OBJECTS { chAlarmVarInteger,
chAlarmVarString,
chAlarmVarSlot,
chAlarmVarPort
}
STATUS current
DESCRIPTION
"The driver/agent generate this trap when a
stack port is disconnected from annother stack member."
::= { chAlarmMibNotifications 7 }
-- ### conformance information ###
f10sSeriesMibConformance OBJECT IDENTIFIER ::= { f10SSerChassisMib 2 }
f10sSeriesMibCompliances OBJECT IDENTIFIER ::= { f10sSeriesMibConformance 1 }
f10sSeriesMibGroups OBJECT IDENTIFIER ::= { f10sSeriesMibConformance 2 }
-- ## compliance statements
f10sSeriesMibCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for Force10
product which implement the f10
S-Series Chassis MIB."
MODULE -- this module
MANDATORY-GROUPS {
f10sSeriesComponentGroup,
f10sSeriesSystemGroup,
f10sSeriesNotificationGroup
}
::= { f10sSeriesMibCompliances 1 }
-- ## units of conformance
f10sSeriesComponentGroup OBJECT-GROUP
OBJECTS {
chNumStackUnits,
chNumMaxStackableUnits,
chStackUnitIndexNext
}
STATUS current
DESCRIPTION
"A collection of objects providing the
overall S-series chassis information."
::= { f10sSeriesMibGroups 1 }
f10sSeriesSystemGroup OBJECT-GROUP
OBJECTS {
chSwitchTypeSID,
chSwitchTypeModelID,
chSwitchTypeCodeType,
chSwitchTypeMgmtPreference,
chStackUnitNumber,
chStackUnitSID,
chStackUnitMgmtStatus,
chStackUnitHwMgmtPreference,
chStackUnitAdmMgmtPreference,
chStackUnitModelID,
chStackUnitStatus,
chStackUnitDescription,
chStackUnitCodeVersion,
chStackUnitCodeVersionInFlash,
chStackUnitSerialNumber,
chStackUnitUpTime,
chStackUnitTemp,
chStackUnitType,
chStackUnitSysType,
chStackUnitVendorId,
chStackUnitMfgDate,
chStackUnitMacAddress,
chStackUnitPartNum,
chStackUnitProductRev,
chStackUnitProductOrder,
chStackUnitCountryCode,
chStackUnitNum10GigEtherPorts,
chStackUnitNumGigEtherPorts,
chStackUnitNumFastEtherPorts,
chStackUnitNumFanTrays,
chStackUnitNumPowerSupplies,
chStackUnitNumPluggableModules,
chStackUnitRowStatus,
chSysPowerSupplyIndex,
chSysPowerSupplyOperStatus,
chSysPowerSupplyType,
chSysFanTrayIndex,
chSysFanTrayOperStatus,
chSysPortIndex,
chSysPortType,
chSysPortAdminStatus ,
chSysPortOperStatus,
chSysPortIfIndex,
chSysPortXfpRecvPower,
chSysStackPortIndex,
chSysStackPortConfiguredMode,
chSysStackPortRunningMode,
chSysStackPortLinkStatus,
chSysStackPortLinkSpeed,
chSysStackPortRxDataRate,
chSysStackPortRxErrorRate,
chSysStackPortRxTotalErrors,
chSysStackPortTxDataRate,
chSysStackPortTxErrorRate,
chSysStackPortTxTotalErrors,
chSysProcessorModule,
chSysProcessorUpTime,
chSysProcessorNvramSize,
chSysProcessorMemSize,
chSysSwRuntimeImgVersion,
chSysSwRuntimeImgDate,
chSysSwCurrentBootImgVersion,
chSysSwCurrentBootImgDate,
chSysSwCurrentBootImgStatus,
chSysSwBackupBootImgVersion,
chSysSwBackupBootImgDate,
chSysSwBackupBootImgStatus,
chSysSwNextRebootImage,
chSysSwCurrentBootImage,
chStackUnitCpuType,
chStackUnitCpuUtil5Sec,
chStackUnitCpuUtil1Min,
chStackUnitCpuUtil5Min,
chStackUnitMemUsageUtil
}
STATUS current
DESCRIPTION
"A collection of objects providing the
chassis system hardware information."
::= { f10sSeriesMibGroups 2 }
f10sSeriesNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
chAlarmStackUnitDown,
chAlarmStackUnitUp,
chAlarmStackUnitReset,
chAlarmStackUnitOffline,
chAlarmStackUnitCodeMismatch,
chAlarmStackPortLinkUp,
chAlarmStackPortLinkDown
}
STATUS current
DESCRIPTION
"Notifications for Force10 S-Series Chassis mib"
::= { f10sSeriesMibGroups 3 }
END