mibs/MIBS/deltanet/LAMBDATRAIL-MIB

1148 lines
30 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
LAMBDATRAIL-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, private, NetworkAddress,
IpAddress, Counter, Gauge, TimeTicks
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212;
DisplayString ::=
OCTET STRING
-- This data type is used to model textual information taken
-- from the NVT ASCII character set. By convention, objects
-- with this syntax are declared as having
--
-- SIZE (0..255)
PhysAddress ::=
OCTET STRING
-- This data type is used to model media addresses. For many
-- types of media, this will be in a binary representation.
-- For example, an ethernet address would be represented as
-- a string of 6 octets.
-- revision date: Apr. 09, 2010
deltanet OBJECT IDENTIFIER ::= { enterprises 35616 }
-- Deltanet AG Specific Objects
snmpAgent OBJECT IDENTIFIER ::= { deltanet 1 }
productType OBJECT IDENTIFIER ::= { deltanet 2 }
cwdm OBJECT IDENTIFIER ::= { productType 1 }
lambdatrail OBJECT IDENTIFIER ::= { cwdm 1 }
-- Software group
agentSw OBJECT IDENTIFIER ::= { snmpAgent 1 }
agentSoftwareMajorVer OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The major software version number of the agent
run time image."
::= { agentSw 1 }
agentSoftwareMinorVer OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minor software version number of the agent
run time image."
::= { agentSw 2 }
agentOutBandBaudRate OBJECT-TYPE
SYNTAX INTEGER {
b9600(9600),
b19200(19200),
b38400(38400),
b57600(57600),
b115200(115200)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The baud rate setting for the out-of-band port."
::= { snmpAgent 2 }
agentConsoleIdleTimeouts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"timeouts is 0 or 60-86400, unit is second, 0: never idle,
default is 600"
::= { snmpAgent 3 }
agentPrompt OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { snmpAgent 4 }
agentBootMethod OBJECT-TYPE
SYNTAX INTEGER {
manual(1),
dhcp(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { snmpAgent 5 }
agentIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The agent's administrative IP address. The
current operational IP address can be obtained from
the ipAdEntAddr in the ipAddrTable. This parameter
will take effect only after a agent restart or
agent reset. This parameter will always be updated
in the EEPROM."
::= { snmpAgent 6 }
agentIpNetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The agent's administrative IP subnet mask. The
current operational IP subnet mask can be obtained from
the ipAdEntMask in the ipAddrTable. This parameter
will take effect only after a agent restart or
agent reset. This parameter will always be updated
in the EEPROM."
::= { snmpAgent 7 }
agentDefaultGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The agent's administrative default gateway IP address.
The current operational IP default gateway IP address
can be obtained from the ipRouteDest in the ipRouteTable.
This parameter will take effect only after a agent restart or
agent reset. This parameter will always be updated
in the EEPROM."
::= { snmpAgent 8 }
agentPrimaryDnsServer OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { snmpAgent 9 }
agentSecondaryDnsServer OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { snmpAgent 10 }
agentSnmpServer OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { snmpAgent 11 }
agentHttpServer OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { snmpAgent 12 }
agentTelnet OBJECT IDENTIFIER ::= { snmpAgent 13 }
agentTelnetServer OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTelnet 1 }
agentTelnetIdleTimeouts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"timeouts is 0 or 60-86400, unit is second, 0: never idle,
default is 600"
::= { agentTelnet 2 }
agentTelnetMaxSessions OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTelnet 3 }
agentFtpServer OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { snmpAgent 14 }
agentTftpServer OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { snmpAgent 15 }
-- the agent trap target group
agentSendTrap OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { snmpAgent 16 }
agentTrapTargetTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentTrapTargetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
::= { snmpAgent 17 }
agentTrapTargetEntry OBJECT-TYPE
SYNTAX AgentTrapTargetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { agentTrapIndex }
::= { agentTrapTargetTable 1 }
AgentTrapTargetEntry ::= SEQUENCE {
agentTrapIndex INTEGER,
agentTrapTargetIpAddr IpAddress,
agentTrapTargetComm DisplayString
}
agentTrapIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { agentTrapTargetEntry 1 }
agentTrapTargetIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTrapTargetEntry 2 }
agentTrapTargetComm OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTrapTargetEntry 3 }
-- the agent email alert group
agentEmailAlert OBJECT IDENTIFIER ::= { snmpAgent 18 }
agentSendEmailAlert OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentEmailAlert 1 }
agentEmailServerIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentEmailAlert 2 }
agentRecipientTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentRecipientEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
::= { agentEmailAlert 3 }
agentRecipientEntry OBJECT-TYPE
SYNTAX AgentRecipientEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { agentRecipientIndex }
::= { agentRecipientTable 1 }
AgentRecipientEntry ::= SEQUENCE {
agentRecipientIndex INTEGER,
agentRecipientEmailAddress DisplayString
}
agentRecipientIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { agentRecipientEntry 1 }
agentRecipientEmailAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..47))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentRecipientEntry 2 }
-- the agent syslog group
agentSyslog OBJECT IDENTIFIER ::= { snmpAgent 19 }
agentSyslogOnOff OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentSyslog 1 }
agentSaveLogsToFlash OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentSyslog 2 }
agentClearAllLogs OBJECT-TYPE
SYNTAX INTEGER {
none(1),
access(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentSyslog 3 }
agentSyslogServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentSyslogServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
::= { agentSyslog 4 }
agentSyslogServerEntry OBJECT-TYPE
SYNTAX AgentSyslogServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { agentSyslogServerIndex }
::= { agentSyslogServerTable 1 }
AgentSyslogServerEntry ::= SEQUENCE {
agentSyslogServerIndex INTEGER,
agentSyslogServerIpAddr IpAddress
}
agentSyslogServerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { agentSyslogServerEntry 1 }
agentSyslogServerIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentSyslogServerEntry 2 }
-- the agent secure ip group
agentSecureIp OBJECT IDENTIFIER ::= { snmpAgent 20 }
agentSecureIpOnOff OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentSecureIp 1 }
agentSecureIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentSecureIpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
::= { agentSecureIp 2 }
agentSecureIpEntry OBJECT-TYPE
SYNTAX AgentSecureIpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { agentSecureIpIndex }
::= { agentSecureIpTable 1 }
AgentSecureIpEntry ::= SEQUENCE {
agentSecureIpIndex INTEGER,
agentSecureIpAddr IpAddress
}
agentSecureIpIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" "
::= { agentSecureIpEntry 1 }
agentSecureIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentSecureIpEntry 2 }
-- the agent ntp group
agentTime OBJECT IDENTIFIER ::= { snmpAgent 21 }
agentNtpClientOnOff OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTime 1 }
agentNtpServerIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTime 2 }
agentNtpUpdateInterval OBJECT-TYPE
SYNTAX INTEGER (60..86400)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"unit is second"
::= { agentTime 3 }
agentTimeZoneName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTime 4 }
agentTimeZoneHoursOffsetWithGMT OBJECT-TYPE
SYNTAX INTEGER (-23..23)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTime 5 }
agentTimeZoneMinutesOffsetWithGMT OBJECT-TYPE
SYNTAX INTEGER (0..59)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTime 6 }
agentSummerTime OBJECT-TYPE
SYNTAX INTEGER {
summer(1),
Sun(2),
lastSun(3),
manual(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTime 7 }
agentSummerTimeBeginMonth OBJECT-TYPE
SYNTAX INTEGER {
jan(1),
feb(2),
mar(3),
apr(4),
may(5),
jun(6),
jul(7),
aug(8),
sep(9),
oct(10),
nov(11),
dec(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTime 8 }
agentSummerTimeBeginNth OBJECT-TYPE
SYNTAX INTEGER {
first(1),
second(2),
third(3),
fourth(4),
last(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTime 9 }
agentSummerTimeBeginWeekday OBJECT-TYPE
SYNTAX INTEGER {
sun(1),
mon(2),
tue(3),
wed(4),
thu(5),
fri(6),
sat(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTime 10 }
agentSummerTimeBeginHour OBJECT-TYPE
SYNTAX INTEGER (0..23)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTime 11 }
agentSummerTimeBeginMinute OBJECT-TYPE
SYNTAX INTEGER (0..59)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTime 12 }
agentSummerTimeEndMonth OBJECT-TYPE
SYNTAX INTEGER {
jan(1),
feb(2),
mar(3),
apr(4),
may(5),
jun(6),
jul(7),
aug(8),
sep(9),
oct(10),
nov(11),
dec(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTime 13 }
agentSummerTimeEndNth OBJECT-TYPE
SYNTAX INTEGER {
first(1),
second(2),
third(3),
fourth(4),
last(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTime 14 }
agentSummerTimeEndWeekday OBJECT-TYPE
SYNTAX INTEGER {
sun(1),
mon(2),
tue(3),
wed(4),
thu(5),
fri(6),
sat(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTime 15 }
agentSummerTimeEndHour OBJECT-TYPE
SYNTAX INTEGER (0..23)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTime 16 }
agentSummerTimeEndMinute OBJECT-TYPE
SYNTAX INTEGER (0..59)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" "
::= { agentTime 17 }
agentSaveRunningCfg OBJECT-TYPE
SYNTAX INTEGER {
none(1),
saveConfiguration(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this variable will save current configuration.
the value will be reset to 1 after succeed."
::= { snmpAgent 22 }
agentDefault OBJECT IDENTIFIER ::= { snmpAgent 23 }
agentKeepCurrentIP OBJECT-TYPE
SYNTAX INTEGER {
none(1),
keepCurrentIP(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this variable will keep current IP configuration
(IP address, Subnet Mask, Default Gateway and Domain Name Servers).
the value will be reset to 1 after succeed."
::= { agentDefault 1 }
agentKeepCurrentSNMP OBJECT-TYPE
SYNTAX INTEGER {
none(1),
keepCurrentSNMP(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this variable will keep current SNMP settings
(System information, SNMP communities and SNMP Trap information).
the value will be reset to 1 after succeed."
::= { agentDefault 2 }
agentKeepCurrentPort OBJECT-TYPE
SYNTAX INTEGER {
none(1),
keepCurrentPort(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this variable will keep current port settings.
the value will be reset to 1 after succeed."
::= { agentDefault 3 }
agentKeepCurrentUser OBJECT-TYPE
SYNTAX INTEGER {
none(1),
keepCurrentUser(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this variable will keep current User settings.
the value will be reset to 1 after succeed."
::= { agentDefault 4 }
agentFactoryDefault OBJECT-TYPE
SYNTAX INTEGER {
none(1),
factoryDefault(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this variable will use factory default configuration and reload.
the value will be reset to 1 after succeed."
::= { agentDefault 5 }
agentReloadSystem OBJECT-TYPE
SYNTAX INTEGER {
none(1),
reloadSystem(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this variable will reload system.
the value will be reset to 1 after succeed."
::= { snmpAgent 24 }
agentTftpUpgrade OBJECT IDENTIFIER ::= { snmpAgent 25 }
agentTftpServerIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specify the IP address of the TFTP server where the binary
code is stored."
::= { agentTftpUpgrade 1 }
agentUpgradeFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specify the file name of the binary code to be upgraded."
::= { agentTftpUpgrade 2 }
agentUpgradeState OBJECT-TYPE
SYNTAX INTEGER {
none(1),
start(2),
inProgress(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set the variable 1 will start the upgrade process."
::= { agentTftpUpgrade 3 }
-- system
systemTemperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { lambdatrail 1 }
systemPower1 OBJECT-TYPE
SYNTAX INTEGER {
notplugged(1),
off(2),
on(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { lambdatrail 2 }
systemPower2 OBJECT-TYPE
SYNTAX INTEGER {
notplugged(1),
off(2),
on(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { lambdatrail 3 }
systemFan1 OBJECT-TYPE
SYNTAX INTEGER {
failure(1),
off(2),
on(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { lambdatrail 4 }
systemFan1Selection OBJECT-TYPE
SYNTAX INTEGER {
alwaysOff(1),
alwaysOn(2),
byTemperature(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { lambdatrail 5 }
systemFan1OnTemperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { lambdatrail 6 }
systemFan1OffTemperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { lambdatrail 7 }
systemFan2 OBJECT-TYPE
SYNTAX INTEGER {
failure(1),
off(2),
on(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { lambdatrail 8 }
systemFan2Selection OBJECT-TYPE
SYNTAX INTEGER {
alwaysOff(1),
alwaysOn(2),
byTemperature(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { lambdatrail 9 }
systemFan2OnTemperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { lambdatrail 10 }
systemFan2OffTemperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { lambdatrail 11 }
-- port table
portTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of interface entries."
::= { lambdatrail 12 }
portEntry OBJECT-TYPE
SYNTAX PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A port entry containing objects
below for a port."
INDEX { portId }
::= { portTable 1 }
PortEntry ::= SEQUENCE {
portId INTEGER,
portLicensed INTEGER,
portEnabled INTEGER,
portAPSD INTEGER,
portLinePlugged INTEGER,
portLineLink INTEGER,
portLineWavelength INTEGER,
portLineTxPower INTEGER,
portLineRxPower INTEGER,
portLineLaserTemp INTEGER,
portLineLaserBias INTEGER,
portClientPlugged INTEGER,
portClientLink INTEGER,
portClientWavelength INTEGER,
portClientTxPower INTEGER,
portClientRxPower INTEGER,
portClientLaserTemp INTEGER,
portClientLaserBias INTEGER,
portName DisplayString
}
portId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each interface."
::= { portEntry 1 }
portLicensed OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { portEntry 2 }
portEnabled OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portEntry 3 }
portAPSD OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portEntry 4 }
portLinePlugged OBJECT-TYPE
SYNTAX INTEGER {
notPlugged(1),
plugged(2),
notAvailable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { portEntry 5 }
portLineLink OBJECT-TYPE
SYNTAX INTEGER {
down(1),
up(2),
notAvailable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { portEntry 6 }
portLineWavelength OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"unit is nanometer, -1 means not available"
::= { portEntry 7 }
portLineTxPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available"
::= { portEntry 8 }
portLineRxPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available"
::= { portEntry 9 }
portLineLaserTemp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"unit is Celsius degree, -1 means not available"
::= { portEntry 10 }
portLineLaserBias OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"unit is mini ampere, -1 means not available"
::= { portEntry 11 }
portClientPlugged OBJECT-TYPE
SYNTAX INTEGER {
notPlugged(1),
plugged(2),
notAvailable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { portEntry 12 }
portClientLink OBJECT-TYPE
SYNTAX INTEGER {
down(1),
up(2),
notAvailable (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { portEntry 13 }
portClientWavelength OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"unit is nanometer, -1 means not available"
::= { portEntry 14 }
portClientTxPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available"
::= { portEntry 15 }
portClientRxPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available"
::= { portEntry 16 }
portClientLaserTemp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"unit is Celsius degree, -1 means not available"
::= { portEntry 17 }
portClientLaserBias OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"unit is mini ampere, -1 means not available"
::= { portEntry 18 }
portName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { portEntry 19 }
--
usablePorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { lambdatrail 13 }
END