mibs/MIBS/enterasys/CTRON-IPX-ROUTER-MIB

4793 lines
180 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
CTRON-IPX-ROUTER-MIB DEFINITIONS ::= BEGIN
-- ctron-ipx-router-mib.txt
-- Revision: 1.01.03
-- Part Number: 2170987
-- Date: August 11, 1995
-- Cabletron Systems, Inc.
-- 35 Industrial Way, P.O. Box 5005
-- Rochester, NH 03867-0505
-- (603) 332-9400
-- support@ctron.com
-- This module provides authoritative definitions for Cabletron's
-- enterprise specific IPX Routing Services MIB.
--
--
-- This module will be extended as required.
--
-- Cabletron Systems reserves the right to make changes in
-- specification and other information contained in this document
-- without prior notice. The reader should consult Cabletron Systems
-- to determine whether any such changes have been made.
--
-- In no event shall Cabletron Systems be liable for any incidental,
-- indirect, special, or consequential damages whatsoever (including
-- but not limited to lost profits) arising out of or related to this
-- document or the information contained in it, even if Cabletron
-- Systems has been advised of, known, or should have known, the
-- possibility of such damages.
--
-- Cabletron grants vendors, end-users, and other interested parties
-- a non-exclusive license to use this Specification in connection
-- with the management of Cabletron products.
-- Copyright August 95 Cabletron Systems
IMPORTS
OBJECT-TYPE
FROM RFC-1212
DisplayString, PhysAddress
FROM RFC1213-MIB
MacAddress
FROM BRIDGE-MIB
nwRtrProtoSuites
FROM ROUTER-OIDS
Counter, TimeTicks, Gauge
FROM RFC1155-SMI;
-- The IPX Router Group.
nwIpxRouter OBJECT IDENTIFIER ::= { nwRtrProtoSuites 2 }
nwIpxMibs OBJECT IDENTIFIER ::= { nwIpxRouter 1 }
nwIpxComponents OBJECT IDENTIFIER ::= { nwIpxRouter 2 }
-- IPX Router Component Groups
nwIpxSystem OBJECT IDENTIFIER ::= { nwIpxComponents 1 }
nwIpxForwarding OBJECT IDENTIFIER ::= { nwIpxComponents 2 }
nwIpxTopology OBJECT IDENTIFIER ::= { nwIpxComponents 4 }
nwIpxFib OBJECT IDENTIFIER ::= { nwIpxComponents 5 }
nwIpxEndSystems OBJECT IDENTIFIER ::= { nwIpxComponents 6 }
nwIpxAccessControl OBJECT IDENTIFIER ::= { nwIpxComponents 7 }
nwIpxFilters OBJECT IDENTIFIER ::= { nwIpxComponents 8 }
nwIpxRedirector OBJECT IDENTIFIER ::= { nwIpxComponents 9 }
nwIpxEvent OBJECT IDENTIFIER ::= { nwIpxComponents 10 }
nwIpxWorkGroup OBJECT IDENTIFIER ::= { nwIpxComponents 11 }
-- IPX Router System Groups
nwIpxSysConfig OBJECT IDENTIFIER ::= { nwIpxSystem 1 }
nwIpxSysAdministration OBJECT IDENTIFIER ::= { nwIpxSystem 2 }
-- IPX Router Forwarding Groups
nwIpxFwdSystem OBJECT IDENTIFIER ::= { nwIpxForwarding 1 }
nwIpxFwdInterfaces OBJECT IDENTIFIER ::= { nwIpxForwarding 2 }
nwIpxFwdCounters OBJECT IDENTIFIER ::= { nwIpxFwdSystem 1 }
nwIpxFwdIfConfig OBJECT IDENTIFIER ::= { nwIpxFwdInterfaces 1 }
nwIpxFwdIfCounters OBJECT IDENTIFIER ::= { nwIpxFwdInterfaces 2 }
-- IPX Router Routing Groups
nwIpxDistanceVector OBJECT IDENTIFIER ::= { nwIpxTopology 1 }
nwIpxLinkState OBJECT IDENTIFIER ::= { nwIpxTopology 2 }
nwIpxRip OBJECT IDENTIFIER ::= { nwIpxDistanceVector 1 }
nwIpxSap OBJECT IDENTIFIER ::= { nwIpxDistanceVector 2 }
nwIpxRipSystem OBJECT IDENTIFIER ::= { nwIpxRip 1 }
nwIpxRipInterfaces OBJECT IDENTIFIER ::= { nwIpxRip 2 }
nwIpxRipDatabase OBJECT IDENTIFIER ::= { nwIpxRip 3 }
nwIpxRipFilters OBJECT IDENTIFIER ::= { nwIpxRip 4 }
nwIpxRipConfig OBJECT IDENTIFIER ::= { nwIpxRipSystem 1 }
nwIpxRipCounters OBJECT IDENTIFIER ::= { nwIpxRipSystem 2 }
nwIpxRipIfConfig OBJECT IDENTIFIER ::= { nwIpxRipInterfaces 1 }
nwIpxRipIfCounters OBJECT IDENTIFIER ::= { nwIpxRipInterfaces 2 }
nwIpxSapSystem OBJECT IDENTIFIER ::= { nwIpxSap 1 }
nwIpxSapInterfaces OBJECT IDENTIFIER ::= { nwIpxSap 2 }
nwIpxSapServerTable OBJECT IDENTIFIER ::= { nwIpxSap 3 }
nwIpxSapFilters OBJECT IDENTIFIER ::= { nwIpxSap 4 }
nwIpxSapConfig OBJECT IDENTIFIER ::= { nwIpxSapSystem 1 }
nwIpxSapCounters OBJECT IDENTIFIER ::= { nwIpxSapSystem 2 }
nwIpxSapIfConfig OBJECT IDENTIFIER ::= { nwIpxSapInterfaces 1 }
nwIpxSapIfCounters OBJECT IDENTIFIER ::= { nwIpxSapInterfaces 2 }
nwIpxNlsp OBJECT IDENTIFIER ::= { nwIpxLinkState 1 }
-- IPX Router Host End Systems Groups
nwIpxHostsSystem OBJECT IDENTIFIER ::= { nwIpxEndSystems 1 }
nwIpxHostsInterfaces OBJECT IDENTIFIER ::= { nwIpxEndSystems 2 }
nwIpxHostsToMedia OBJECT IDENTIFIER ::= { nwIpxEndSystems 3 }
-- IPX Router Access Control Group
-- IPX Router Redirector Group
nwIpxNetBIOS OBJECT IDENTIFIER ::= { nwIpxRedirector 1 }
nwIpxBroadcast OBJECT IDENTIFIER ::= { nwIpxRedirector 2 }
nwIpxEcho OBJECT IDENTIFIER ::= { nwIpxRedirector 3 }
nwIpxNetBIOSSystem OBJECT IDENTIFIER ::= { nwIpxNetBIOS 1 }
nwIpxNetBIOSInterface OBJECT IDENTIFIER ::= { nwIpxNetBIOS 2 }
nwIpxNetBIOSConfig OBJECT IDENTIFIER ::= { nwIpxNetBIOSSystem 1 }
nwIpxNetBIOSCounters OBJECT IDENTIFIER ::= { nwIpxNetBIOSSystem 2 }
nwIpxNetBIOSIfConfig OBJECT IDENTIFIER ::= { nwIpxNetBIOSInterface 1}
nwIpxNetBIOSIfCounters OBJECT IDENTIFIER ::= { nwIpxNetBIOSInterface 2}
nwIpxBroadcastSystem OBJECT IDENTIFIER ::= { nwIpxBroadcast 1 }
nwIpxBroadcastInterface OBJECT IDENTIFIER ::= { nwIpxBroadcast 2 }
nwIpxBroadcastConfig OBJECT IDENTIFIER ::= { nwIpxBroadcastSystem 1 }
nwIpxBroadcastCounters OBJECT IDENTIFIER ::= { nwIpxBroadcastSystem 2 }
nwIpxBroadcastIfConfig OBJECT IDENTIFIER ::= { nwIpxBroadcastInterface 1 }
nwIpxBroadcastIfCounters OBJECT IDENTIFIER ::= { nwIpxBroadcastInterface 2 }
nwIpxEchoSystem OBJECT IDENTIFIER ::= { nwIpxEcho 1 }
nwIpxEchoInterface OBJECT IDENTIFIER ::= { nwIpxEcho 2 }
nwIpxEchoConfig OBJECT IDENTIFIER ::= { nwIpxEchoSystem 1 }
nwIpxEchoCounters OBJECT IDENTIFIER ::= { nwIpxEchoSystem 2 }
nwIpxEchoIfConfig OBJECT IDENTIFIER ::= { nwIpxEchoInterface 1 }
nwIpxEchoIfCounters OBJECT IDENTIFIER ::= { nwIpxEchoInterface 2 }
-- IPX Router Event Log Group
nwIpxEventLogConfig OBJECT IDENTIFIER ::= { nwIpxEvent 1 }
nwIpxEventLogFilterTable OBJECT IDENTIFIER ::= { nwIpxEvent 2 }
nwIpxEventLogTable OBJECT IDENTIFIER ::= { nwIpxEvent 3 }
-- IPX Router Work-Group Group
IpxAddress ::= OCTET STRING
-- MacAddress ::= OCTET STRING (SIZE (6))
-- IPX MIB Group
-- This group contains information about the revision level of this
-- MIB within the device. It allows verification of the released
-- version without having to read other objects.
nwIpxMibRevText OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current revision level of the IPX MIB in textual
format."
::= { nwIpxMibs 1 }
-- IPX Router System Group
-- This group contains the objects related to the IPX Router at a
-- global device-wide level.
-- IPX System Configuration Group
-- This group contains the objects that pertain to the setup and
-- configuration of the IPX routing services at a global,
-- device-wide level.
nwIpxSysRouterId OBJECT-TYPE
SYNTAX IpxAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IPX Address used to uniquely identify the host (device) running
IPX Routing Services. The value of nwIpxSysRouterId is equal to the
highest IPX address assigned in the IPX Address Table."
::= { nwIpxSysConfig 1 }
-- IPX System Administration Group
-- This group contains the objects that pertain to the administration of
-- IPX routing services at a global, device-wide level.
nwIpxSysAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
disabled(2), -- shutdown the router
enabled(3) -- startup the router
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of IPX Routing Services system-wide.
Enabled (3) causes IPX Routing Services to become active on all router
ports configured and enabled for IPX Routing Services. Disabled (2)
causes IPX routing services to become inactive system-wide."
DEFVAL { disabled }
::= { nwIpxSysAdministration 1 }
nwIpxSysOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
disabled(2), -- not running
enabled(3), -- running
pending-disable(4), -- shut-down in progress
pending-enable(5), -- start-up in progress
invalid-config(6) -- not running,invalid config
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the operating condition of IPX Routing Services system-wide.
The value of nwIpxSysOperStatus indicates any problem with your IPX
Routing Services configuration. A value of 6 indicates that regardless
of the value of nwIpxSysAdminStatus, IPX Routing Services is not
operating because of an invalid configuration."
::= { nwIpxSysAdministration 2 }
nwIpxSysAdminReset OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
reset(2) -- force a reset
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets IPX Routing Services system-wide. Reset (2) forces a restart
of IPX Routing Services without a graceful shutdown on any active
router ports and without affecting any other routing services."
DEFVAL { other }
::= { nwIpxSysAdministration 3 }
nwIpxSysOperationalTimel OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the elapsed time, in hundredths of a second, that
nwIpxSysOperStatus has been in its current administrative state."
::= { nwIpxSysAdministration 4 }
nwIpxSysVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current revision level of the IPX Routing Services
firmware in textual format."
::= { nwIpxSysAdministration 5 }
-- IPX Forwarding Group
-- This group contains the managed objects used to setup and configure
-- the IPX router port for packet forwarding as well as the aggregate
-- and per-interface IPX packet forwarding counters.
-- IPX System-wide Packet Forwarding Counters
-- This group contains the aggregate (device-wide) IPX packet forwarding
-- counters. The byte counters include bytes for the network layer on
-- up, framing is not included.
nwIpxFwdCtrAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the aggregate (system-wide) IPX
packet and byte counters. Enabled (3) causes these counters to become
active. Disabled (2) causes these counters to become inactive."
DEFVAL { enabled }
::= { nwIpxFwdCounters 1 }
nwIpxFwdCtrReset OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the aggregate (system-wide) IPX packet and byte counters.
Reset (2) resets the IPX aggregate counters to 0.
nwIpxFwdCtrOperationalTime is also reset to 0."
DEFVAL { other }
::= { nwIpxFwdCounters 2 }
nwIpxFwdCtrOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the elapsed time, in hundredths of a second, that
nwIpxFwdCtrAdminStatus has been in the current state."
::= { nwIpxFwdCounters 3 }
nwIpxFwdCtrInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been received,
system-wide, during nwIpxFwdCtrOperationalTime."
::= { nwIpxFwdCounters 4 }
nwIpxFwdCtrOutPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been transmitted,
system-wide, during nwIpxFwdCtrOperationalTime."
::= { nwIpxFwdCounters 5 }
nwIpxFwdCtrFwdPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been forwarded,
system-wide, during nwIpxFwdCtrOperationalTime."
::= { nwIpxFwdCounters 6 }
nwIpxFwdCtrFilteredPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been
administratively filtered, system-wide, during
nwIpxFwdCtrOperationalTime."
::= { nwIpxFwdCounters 7 }
nwIpxFwdCtrDiscardPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been discarded,
system-wide, during nwIpxFwdCtrOperationalTime."
::= { nwIpxFwdCounters 8 }
nwIpxFwdCtrAddrErrPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been discarded,
system-wide, during nwIpxFwdCtrOperationalTime, because of addressing
errors in the IPX header."
::= { nwIpxFwdCounters 9 }
nwIpxFwdCtrLenErrPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been discarded,
system-wide, during nwIpxFwdCtrOperationalTime, because an invalid
packet length is contained in the IPX header."
::= { nwIpxFwdCounters 10 }
nwIpxFwdCtrHdrErrPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been discarded,
system-wide, during nwIpxFwdCtrOperationalTime, because of an invalid
IPX header."
::= { nwIpxFwdCounters 11 }
nwIpxFwdCtrInBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX packets that have
been received, system-wide, during nwIpxFwdCtrOperationalTime."
::= { nwIpxFwdCounters 12 }
nwIpxFwdCtrOutBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX packets that have
been transmitted, system-wide, during nwIpxFwdCtrOperationalTime."
::= { nwIpxFwdCounters 13 }
nwIpxFwdCtrFwdBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX packets that have
been forwarded, system-wide, during nwIpxFwdCtrOperationalTime."
::= { nwIpxFwdCounters 14 }
nwIpxFwdCtrFilteredBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX packets that have
been administratively filtered, system-wide, during
nwIpxFwd-CtrOperationalTime."
::= { nwIpxFwdCounters 15 }
nwIpxFwdCtrDiscardBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX packets that have
been discarded, system-wide during nwIpxFwdCtrOperationalTime."
::= { nwIpxFwdCounters 16 }
nwIpxFwdCtrHostInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been successfully
delivered to the local host, during nwIpxFwdCtrOperationalTime."
::= { nwIpxFwdCounters 17 }
nwIpxFwdCtrHostOutPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been transmitted
by the local host, during nwIpxFwdCtrOperationalTime."
::= { nwIpxFwdCounters 18 }
nwIpxFwdCtrHostDiscardPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been discarded
by the local host, during nwIpxFwdCtrOperationalTime, due to a lack of
host resources."
::= { nwIpxFwdCounters 19 }
nwIpxFwdCtrHostInBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX packets that have
been received by the local host, during nwIpxFwdCtrOperationalTime."
::= { nwIpxFwdCounters 20 }
nwIpxFwdCtrHostOutBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX packets that have
been transmitted by the local host, during
nwIpxFwdCtrOperationalTime."
::= { nwIpxFwdCounters 21 }
nwIpxFwdCtrHostDiscardBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX packets that have
been discarded by the local host, during nwIpxFwdCtrOperationalTime
due to a lack of host resources."
::= { nwIpxFwdCounters 22 }
-- IPX Forwarding Interface Table
-- This table contains the managed objects used to set-up and configure
-- each router port.
nwIpxFwdIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxFwdIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains an entry for each router port. This table is
indexed by nwIpxFwdIfIndex, which indicates the value of MIB2
ifIndex, which identifies the router port for which the entry exists."
::= { nwIpxFwdIfConfig 1 }
nwIpxFwdIfEntry OBJECT-TYPE
SYNTAX NwIpxFwdIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry specifies the IPX Routing Services configuration for the
router port for which the entry exists."
INDEX { nwIpxFwdIfIndex }
::= { nwIpxFwdIfTable 1 }
NwIpxFwdIfEntry ::=
SEQUENCE {
nwIpxFwdIfIndex INTEGER,
nwIpxFwdIfAdminStatus INTEGER,
nwIpxFwdIfOperStatus INTEGER,
nwIpxFwdIfOperationalTime TimeTicks,
nwIpxFwdIfControl INTEGER,
nwIpxFwdIfMtu INTEGER,
nwIpxFwdIfForwarding INTEGER,
nwIpxFwdIfFrameType INTEGER,
nwIpxFwdIfAclIdentifier INTEGER,
nwIpxFwdIfAclStatus INTEGER,
nwIpxFwdIfCacheControl INTEGER,
nwIpxFwdIfCacheEntries Counter,
nwIpxFwdIfCacheHits Counter,
nwIpxFwdIfCacheMisses Counter
}
nwIpxFwdIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the value of MIB 2 ifindex, which identifies the router
port for which the entry exists."
::= { nwIpxFwdIfEntry 1 }
nwIpxFwdIfAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of IPX Routing Services on the router
port for which the entry exists. Enabled (3) causes IPX Routing
Services to become active. Disabled (2) causes it to become inactive."
DEFVAL { enabled }
::= { nwIpxFwdIfEntry 2 }
nwIpxFwdIfOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
disabled(2), -- not running
enabled(3), -- running
pending-disable(4), -- shut-down in progress
pending-enable(5), -- start-up in progress
invalid-config(6) -- not running,invalid config
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current operating condition of IPX Routing Services on
the router port for which the entry exists. The value of
nwIpxFwdIfOperStatus indicates any problem with the configuration of
IPX Routing Services on the router port. A value of 6 indicates that
regardless of the state of nwIpxFwdIfAdminStatus IPX Routing Services
is not operating because of an invalid port-level configuration."
::= { nwIpxFwdIfEntry 3 }
nwIpxFwdIfOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the elapsed time, in hundredths of a second, that
nwIpxFwdIfOperStatus has been in its current state."
::= { nwIpxFwdIfEntry 4 }
nwIpxFwdIfControl OBJECT-TYPE
SYNTAX INTEGER {
other(1),
add(2),
delete(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object does not apply to this protocol. It is a common object
inherited from the MIB framework used to provide a common management
interface to all the Cabletron Routing Services protocol-specific MIBs.
Setting this object has no effect."
DEFVAL { delete }
::= { nwIpxFwdIfEntry 5 }
nwIpxFwdIfMtu OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the Maximum Transmission Unit (MTU) for IPX packets on the
router port for which the entry exists. This includes the IPX header
and data but does not include framing."
DEFVAL { 1500 }
::= { nwIpxFwdIfEntry 6 }
nwIpxFwdIfForwarding OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls forwarding of IPX packets on the router port for which the
entry exists. Enabled (3) causes IPX packets to be forwarded. Disabled
(2) prevents IPX packets from being forwarded."
DEFVAL { disabled }
::= { nwIpxFwdIfEntry 7 }
nwIpxFwdIfFrameType OBJECT-TYPE
SYNTAX INTEGER { -- valid media types
other(1), -- experimental
ethernet(2), -- ethernet
snap(3), -- enet,fddi,and token ring
i8022(4), -- enet, token ring, and fddi
novell(6), -- ethernet and fddi
nativewan(8), -- wan media types
encapenet(9), -- wan media types
encapenet8022(10), -- wan media types
encapenetsnap(11), -- wan media types
encapenetnovell(12), -- wan media types
encaptr8022(13), -- wan media types
encaptrsnap(14), -- wan media types
encapfddi8022(15), -- wan media types
encapfddisnap(16), -- wan media types
canonical(17) -- special, tbd
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the framing type for IPX packets forwarded on the router
port for which the entry exists. Some frame types are valid for
specific media types. The comments reflect those valid media types."
DEFVAL { i8022 }
::= { nwIpxFwdIfEntry 8 }
nwIpxFwdIfAclIdentifier OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the Access Control ID of the Access Control List in effect
for IPX packets being routed on the router port for which the entry
exists. A value of 0 indicates that no Access Control List is in
effect."
DEFVAL { 0 }
::= { nwIpxFwdIfEntry 9 }
nwIpxFwdIfAclStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls the operation of any Access Control List configured for IPX
traffic on the router port for which the entry exists. Enabled (3)
applies the Access Control List indicated by the value of
nwIpxFwdIfAclIdentifier to all IPX traffic being routed to the port.
Disabled (2) prevents the Access Control List from being applied."
DEFVAL { disabled }
::= { nwIpxFwdIfEntry 10 }
nwIpxFwdIfCacheControl OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disable(2),
enable(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls IPX Address caching on the router port for which the entry
exists. When IPX Address caching is enabled, IPX Addresses used for
address validation, filtering, and forwarding are stored in the cache.
This cache is checked first before doing a full route table lookup,
which speeds up the switching process. Enabled (3) turns on IPX
Address caching. Disabled (2) turns it off."
DEFVAL { enable }
::= { nwIpxFwdIfEntry 11 }
nwIpxFwdIfCacheEntries OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of entries in the IPX Address cache on the router port for which the entry exists."
::= { nwIpxFwdIfEntry 12 }
nwIpxFwdIfCacheHits OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of times entries in the IPX Adddress cache have
been used to provide the IPX Address required to validate, filter, or
forward an IPX packet on the router port."
::= { nwIpxFwdIfEntry 13 }
nwIpxFwdIfCacheMisses OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of times the IPX Address required to validate,
filter, or forward an IPX packet on the router port was not found in
the IPX Address cache."
::= { nwIpxFwdIfEntry 14 }
-- The IPX Interface Address Table
-- This table contains the managed object used to setup and configure
-- IPX addresses on a per router port basis.
nwIpxAddressTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxAddrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains an entry for each Novell network address assigned
to each router port."
::= { nwIpxFwdIfConfig 2 }
nwIpxAddrEntry OBJECT-TYPE
SYNTAX NwIpxAddrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry specifies the Novell network addressing information for
the logical Novll network for which the entry exists."
INDEX { nwIpxAddrIfIndex, nwIpxAddrIfAddress }
::= { nwIpxAddressTable 1 }
NwIpxAddrEntry ::=
SEQUENCE {
nwIpxAddrIfIndex INTEGER,
nwIpxAddrIfAddress IpxAddress,
nwIpxAddrIfControl INTEGER,
nwIpxAddrIfAddrType INTEGER
}
nwIpxAddrIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the value of MIB 2 ifindex, which identifies the router
port for which the entry exists."
::= { nwIpxAddrEntry 1 }
nwIpxAddrIfAddress OBJECT-TYPE
SYNTAX IpxAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the Novell network number assigned to the logical Novell
network for which the entry exists. The IpxAddress consists of a
network number of 4 octets."
::= { nwIpxAddrEntry 2 }
nwIpxAddrIfControl OBJECT-TYPE
SYNTAX INTEGER {
other(1),
add(2),
delete(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this object to add or delete this entry from the table."
DEFVAL { add }
::= { nwIpxAddrEntry 3 }
nwIpxAddrIfAddrType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
primary(2),
secondary(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies whether the Novell network number, nwIpxAddrIfAddress, is
the primary or secondary address for the router port."
DEFVAL { primary }
::= { nwIpxAddrEntry 4 }
-- IPX Forwarding Interfaces Counter Table
-- This table contains the objects that specify the packet and byte counters
-- for each configured IPX router port.
nwIpxFwdIfCtrTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxFwdIfCtrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains an entry for each router port configured and
enabled for IPX Routing Services."
::= { nwIpxFwdIfCounters 1 }
nwIpxFwdIfCtrEntry OBJECT-TYPE
SYNTAX NwIpxFwdIfCtrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry indicates the current packet and byte count of IPX packets
on the port for which the entry exists."
INDEX { nwIpxFwdIfCtrIfIndex }
::= { nwIpxFwdIfCtrTable 1 }
NwIpxFwdIfCtrEntry ::=
SEQUENCE {
nwIpxFwdIfCtrIfIndex INTEGER,
nwIpxFwdIfCtrAdminStatus INTEGER,
nwIpxFwdIfCtrReset INTEGER,
nwIpxFwdIfCtrOperationalTime TimeTicks,
nwIpxFwdIfCtrInPkts Counter,
nwIpxFwdIfCtrOutPkts Counter,
nwIpxFwdIfCtrFwdPkts Counter,
nwIpxFwdIfCtrFilteredPkts Counter,
nwIpxFwdIfCtrDiscardPkts Counter,
nwIpxFwdIfCtrAddrErrPkts Counter,
nwIpxFwdIfCtrLenErrPkts Counter,
nwIpxFwdIfCtrHdrErrPkts Counter,
nwIpxFwdIfCtrInBytes Counter,
nwIpxFwdIfCtrOutBytes Counter,
nwIpxFwdIfCtrFwdBytes Counter,
nwIpxFwdIfCtrFilteredBytes Counter,
nwIpxFwdIfCtrDiscardBytes Counter,
nwIpxFwdIfCtrHostInPkts Counter,
nwIpxFwdIfCtrHostOutPkts Counter,
nwIpxFwdIfCtrHostDiscardPkts Counter,
nwIpxFwdIfCtrHostInBytes Counter,
nwIpxFwdIfCtrHostOutBytes Counter,
nwIpxFwdIfCtrHostDiscardBytes Counter
}
nwIpxFwdIfCtrIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the value of MIB 2 ifindex, which identifies the router
port for which the entry exists."
::= { nwIpxFwdIfCtrEntry 1 }
nwIpxFwdIfCtrAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the per-port IPX packet and byte
counters on the router port for which the entry exists. Enabled (3)
causes these counters to become active. Disabled (2) causes these
counters to become inactive."
DEFVAL { enabled }
::= { nwIpxFwdIfCtrEntry 2 }
nwIpxFwdIfCtrReset OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the per-port IPX packet and byte counters on the router port
for which this entry exists. Reset (2) resets the counters to 0.
nwIpxFwdIfCtrOperationalTime is also reset to 0."
DEFVAL { other }
::= { nwIpxFwdIfCtrEntry 3 }
nwIpxFwdIfCtrOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the elapsed time, in hundredths of a second, that
nwIpxFwdIfCtrAdminStatus has been in the current state."
::= { nwIpxFwdIfCtrEntry 4 }
nwIpxFwdIfCtrInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been received,
during nwIpxFwdIfCtrOperationaltime, on the router port for which the
entry exists."
::= { nwIpxFwdIfCtrEntry 5 }
nwIpxFwdIfCtrOutPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been transmitted,
during nwIpxFwdIfCtrOperationalTime, on the router port for which the
entry exists."
::= { nwIpxFwdIfCtrEntry 6 }
nwIpxFwdIfCtrFwdPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been forwarded,
during nwIpxFwdIfCtrOperationalTime, on the router port for which the
entry exists."
::= { nwIpxFwdIfCtrEntry 7 }
nwIpxFwdIfCtrFilteredPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been
administratively filtered, during nwIpxFwdIfCtrOperationalTime, on
the router port for which the entry exists."
::= { nwIpxFwdIfCtrEntry 8 }
nwIpxFwdIfCtrDiscardPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been discarded
(dropped), during nwIpxFwdIfCtrOperationalTime, on the router port for
which the entry exists."
::= { nwIpxFwdIfCtrEntry 9 }
nwIpxFwdIfCtrAddrErrPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been discarded
because of IPX addressing errors in the IPX header, during
nwIpxFwdIfCtrOperationalTime, on the router port for which the entry
exists."
::= { nwIpxFwdIfCtrEntry 10 }
nwIpxFwdIfCtrLenErrPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been discarded
because an invalid packet length was contained in the IPX header,
during nwIpxFwdIfCtrOperationalTime, on the router port for which the
entry exists."
::= { nwIpxFwdIfCtrEntry 11 }
nwIpxFwdIfCtrHdrErrPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been discarded
because of an invalid IPX header, during nwIpxFwdIfCtrOperationalTime,
on the router port for which the entry exists."
::= { nwIpxFwdIfCtrEntry 12 }
nwIpxFwdIfCtrInBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX packets that have
been received, during nwIpxFwdIfCtrOperationalTime, on the router
port for which the entry exists."
::= { nwIpxFwdIfCtrEntry 13 }
nwIpxFwdIfCtrOutBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX packets that have
been transmitted, during nwIpxFwdIfCtrOperationalTime, on the router
port for which the entry exists."
::= { nwIpxFwdIfCtrEntry 14 }
nwIpxFwdIfCtrFwdBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX packets that have
been forwarded, during nwIpxFwdCtrOperationalTime, on the router port
for which the entry exists."
::= { nwIpxFwdIfCtrEntry 15 }
nwIpxFwdIfCtrFilteredBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX packets
administratively filtered, during nwIpxFwdIfCtrOperationalTime, on
the router port for which the entry exists."
::= { nwIpxFwdIfCtrEntry 16 }
nwIpxFwdIfCtrDiscardBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX packets that have
been discarded, during nwIpxFwdIfCtrOperationalTime, on the router
port for which the entry exists."
::= { nwIpxFwdIfCtrEntry 17 }
nwIpxFwdIfCtrHostInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been successfully
delivered to the local host, during nwIpxFwdIfCtrOperationalTime, that
were received on the router port for which the entry exists."
::= { nwIpxFwdIfCtrEntry 18 }
nwIpxFwdIfCtrHostOutPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been forwarded
by the local host, during nwIpxFwdIfCtrOperationalTime, on the router
port for which the entry exists."
::= { nwIpxFwdIfCtrEntry 19 }
nwIpxFwdIfCtrHostDiscardPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX packets that have been discarded
by the local host, due to a lack of host resources, during
nwIpxFwdIfCtrOperationalTime, that were received on the router port
for which the entry exists."
::= { nwIpxFwdIfCtrEntry 20 }
nwIpxFwdIfCtrHostInBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX packets that have been
successfully delivered to the local host, during
nwIpxFwdIfCtrOperationalTime, that were received on the router port for
which the entry exists."
::= { nwIpxFwdIfCtrEntry 21 }
nwIpxFwdIfCtrHostOutBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX packets that have been
transmitted by the local host, during nwIpxFwdIfCtrOperationalTime, on
the router port for which the entry exists."
::= { nwIpxFwdIfCtrEntry 22 }
nwIpxFwdIfCtrHostDiscardBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX packets that have
been discarded by the local host, due to a lack of host resources
that were received, during nwIpxFwdIfCtrOperationalTime, that were
received on the router port for which the entry exists."
::= { nwIpxFwdIfCtrEntry 23 }
-- DistanceVector-based Protocols
-- This group contains the managed objects for RIP, IPX DistanceVector based
-- routing.
-- IPX RIP System Configuration Parameters
-- This group contains the objects that pertain to the setup and
-- configuration of the IPX RIP DistanceVector based routing protocol.
nwIpxRipAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
disabled(2), -- shutdown the router
enabled(3) -- startup the router
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the IPX-RIP routing protocol
system-wide. Enabled (3) causes IPX-RIP to become active on all router
ports configured and enabled for IPX Routing Services. Disabled (2)
causes IPX-RIP to become inactive."
DEFVAL { disabled }
::= { nwIpxRipConfig 1 }
nwIpxRipOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
disabled(2), -- not running
enabled(3), -- running
pending-disable(4), -- shut-down in progress
pending-enable(5) -- start-up in progress
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current operating condition of IPX-RIP system-wide.
The value of nwIpxRipOperStatus indicates any problem with your
IPX-RIP configuration. A value of 6 indicates that regardless of the
value of nwIpxRipAdminStatus, IPX-RIP is not operating because of an
invalid configuration."
::= { nwIpxRipConfig 2 }
nwIpxRipAdminReset OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
reset(2) -- force a reset
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the IPX-RIP routing protocol. Reset (2) forces a system-wide
restart of IPX-RIP, without a graceful shutdown on any active router
ports."
DEFVAL { other }
::= { nwIpxRipConfig 3 }
nwIpxRipOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the elapsed time, in hundredths of a second, that
nwIpxRipOperStatus has been in its current state."
::= { nwIpxRipConfig 4 }
nwIpxRipVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current revision level of the IPX-RIP routing protocol
firmware, in textual format."
::= { nwIpxRipConfig 5 }
nwIpxRipStackSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the stack size of the IPX-RIP routing protocol thread. In
order for a change of this value to take effect, the protocol
(nwIpxRipAdminReset), IPX Routing Services (nwIpxSysAdminReset), or
the device running Routing Services must be reset."
DEFVAL { 4096 }
::= { nwIpxRipConfig 6 }
nwIpxRipThreadPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the run-time execution priority of the IPX-RIP routing
protocol thread. In order for a change of this value to take effect,
IPX-RIP (nwIpxRipAdminReset), IPX Routing Services (nwIpxAdminReset),
or the device running Routing services must be reset."
DEFVAL { 127 }
::= { nwIpxRipConfig 7 }
nwIpxRipDatabaseThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the run-time maximum number of IPX-RIP entries that can
be held in the IPX-RIP route table."
DEFVAL { 2000 }
::= { nwIpxRipConfig 8 }
nwIpxRipAgeOut OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the amount of time, in seconds, that an inactive route
table entry remains in the IPX-RIP route table before it is aged-out."
DEFVAL { 180 }
::= { nwIpxRipConfig 9 }
nwIpxRipHoldDown OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the amount of time, in seconds, to wait before removing
an entry from the route table, after receiving an update indicating
that the destination has become unreachable. All routers exchanging
IPX-RIP information must have the same hold down time. The time must
be long enough to allow all participating routers to receive the same
update."
DEFVAL { 120 }
::= { nwIpxRipConfig 10 }
-- IPX RIP System (aggregate) Counters
-- This group contains the aggregate (device-wide) IPX RIP packet and
-- byte counters.
nwIpxRipCtrAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the aggregate system-wide IPX-RIP
packet and byte counters. Enabled (3) causes these counters to become
active on all router ports. Disabled (2) causes these counters to
become inactive."
DEFVAL { enabled }
::= { nwIpxRipCounters 1 }
nwIpxRipCtrReset OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the aggregate system-wide IPX-RIP protocol packet and byte
counters. Reset (2) resets the IPX-RIP aggregate counters to 0.
nwIpxRipCtrOperationalTime is also reset to 0."
DEFVAL { other }
::= { nwIpxRipCounters 2 }
nwIpxRipCtrOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the elapsed time, in hundredths of a second, that
nwIpxRipCtrAdminStatus has been in the current state."
::= { nwIpxRipCounters 3 }
nwIpxRipCtrInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX-RIP packets that have been
received, system-wide, during nwIpxRipCtrOperationalTime."
::= { nwIpxRipCounters 4 }
nwIpxRipCtrOutPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX-RIP packets that have been
transmitted, system-wide, during nwIpxRipCtrOperationalTime."
::= { nwIpxRipCounters 5 }
nwIpxRipCtrFilteredPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX-RIP packets that have been
administratively filtered, system-wide, during`
nwIpxRipCtrOperationalTime."
::= { nwIpxRipCounters 6 }
nwIpxRipCtrDiscardPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX-RIP packets that have been
discarded, system-wide, during nwIpxRipCtrOperationalTime."
::= { nwIpxRipCounters 7 }
nwIpxRipCtrInBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX-RIP packets that
have been received, system-wide, during nwIpxRipCtrOperationalTime."
::= { nwIpxRipCounters 8 }
nwIpxRipCtrOutBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX-RIP packets that have
been transmitted, system-wide, during nwIpxRipCtrOperationalTime."
::= { nwIpxRipCounters 9 }
nwIpxRipCtrFilteredBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX-RIP packets that have
been administratively filtered, system-wide, during
nwIpxRipCtrOperationalTime."
::= { nwIpxRipCounters 10 }
nwIpxRipCtrDiscardBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX-RIP packets that have
been discarded, during nwIpxRipCtrOperationalTime."
::= { nwIpxRipCounters 11 }
-- IPX RIP Interface Table
-- This table contains the managed objects used to setup and configure
-- RIP on a per router port basis.
nwIpxRipIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxRipIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains an entry for each router port. Each entry can
contain different values, allowing the routing protocol configuration
to vary from router port to router port. This table is indexed by
nwIpxRipIfIndex, which indicates the value of MIB 2 ifindex, which
identifies the router port for which each entry exists."
::= { nwIpxRipIfConfig 1 }
nwIpxRipIfEntry OBJECT-TYPE
SYNTAX NwIpxRipIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the IPX-RIP configuration for the router port for
which the entry exists."
INDEX { nwIpxRipIfIndex }
::= { nwIpxRipIfTable 1 }
NwIpxRipIfEntry ::=
SEQUENCE {
nwIpxRipIfIndex INTEGER,
nwIpxRipIfAdminStatus INTEGER,
nwIpxRipIfOperStatus INTEGER,
nwIpxRipIfOperationalTime TimeTicks,
nwIpxRipIfVersion INTEGER,
nwIpxRipIfAdvertisement INTEGER,
nwIpxRipIfFloodDelay INTEGER,
nwIpxRipIfRequestDelay INTEGER,
nwIpxRipIfPriority INTEGER,
nwIpxRipIfHelloTimer INTEGER,
nwIpxRipIfSplitHorizon INTEGER,
nwIpxRipIfPoisonReverse INTEGER,
nwIpxRipIfSnooping INTEGER,
nwIpxRipIfType INTEGER,
nwIpxRipIfXmitCost INTEGER,
nwIpxRipIfAclIdentifier INTEGER,
nwIpxRipIfAclStatus INTEGER
}
nwIpxRipIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the value of MIB 2 ifindex, which identifies the router
port for which the entry exists."
::= { nwIpxRipIfEntry 1 }
nwIpxRipIfAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the IPX-RIP routing protocol on the
router port for which the entry exists. Enabled (3) causes IPX-RIP to
become active on the router port. Disabled (2) causes RIP to become
inactive."
DEFVAL { disabled }
::= { nwIpxRipIfEntry 2 }
nwIpxRipIfOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
disabled(2), -- not running
enabled(3), -- running
pending-disable(4), -- shut-down in progress
pending-enable(5) -- start-up in progress
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current operating condition of the IPX-RIP routing
protocol on the router port for which the entry exists. The value of
nwIpxRipIfOperStatus indicates any problem with your IPX-RIP
configuration on the router port. A value of 6 indicates that
regardless of the value of nwIpxRipIfAdminStatus, IPX-RIP is not
operating on the router port because of an invalid configuration."
::= { nwIpxRipIfEntry 3 }
nwIpxRipIfOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the elapsed time, in hundredths of a second, that
nwIpxRipIfOperStatus has been in its current state."
::= { nwIpxRipIfEntry 4 }
nwIpxRipIfVersion OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the revision level of the IPX-RIP routing protocol in
textual format."
DEFVAL { 1 }
::= { nwIpxRipIfEntry 5 }
nwIpxRipIfAdvertisement OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the interval, in seconds, at which IPX-RIP advertises its route
table on the router port for which the entry exists. Change this value
to cause IPX-RIP to advertise its route table more or less frequently."
DEFVAL { 60 }
::= { nwIpxRipIfEntry 6 }
nwIpxRipIfFloodDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the length of time, in seconds, that the IPX-RIP routing
protocol will wait after discovering that a directly connected route
has gone down, before flooding updates (triggered updates) on the
router port for which the entry exists. A value of 0 specifies that
if a directly connected route goes down, updates will be sent
immediately."
DEFVAL { 2 }
::= { nwIpxRipIfEntry 7 }
nwIpxRipIfRequestDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the length of time, in seconds, that the IPX-RIP routing
protocol will wait after receiving a route request packet before
sending a response on the router port for which the entry exists. A
value of 0 specifies that if a route request packet is received on
the port, a response will be sent immediately."
DEFVAL { 6 }
::= { nwIpxRipIfEntry 8 }
nwIpxRipIfPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object does not apply to this protocol. It is a common object,
inherited from the MIB framework used to provide a common management
interface to all the Cabletron Routing Services protocol-specific MIBs.
Setting this object has no effect."
DEFVAL { 1 }
::= { nwIpxRipIfEntry 9 }
nwIpxRipIfHelloTimer OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object does not apply to this protocol. It is a common object,
inherited from the MIB framework used to provide a common management
interface to all the Cabletron Routing Services protocol-specific
MIBs. Setting this object has no effect."
DEFVAL { 10 }
::= { nwIpxRipIfEntry 10 }
nwIpxRipIfSplitHorizon OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls the operation of Split Horizon on the router port for which
the entry exists. When Split Horizon is enabled, IPX-RIP keeps track
of which router port route information is received on, and prevents
information about a route from being sent back out the same router
port it was received on."
DEFVAL { enabled }
::= { nwIpxRipIfEntry 11 }
nwIpxRipIfPoisonReverse OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls the operation of Poison Reverse on the router port for
which the entry exists. When Poison Reverse is enabled, IPX-RIP
advertises any downed route as unreachable during the period of time
that it must wait (nwIpxRipHoldDown) before removing the route from
the route table."
DEFVAL { disabled }
::= { nwIpxRipIfEntry 12 }
nwIpxRipIfSnooping OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls the operation of IPX-RIP Snooping on the router port. When
RIP Snooping is enabled the IPX-RIP routing protocol operates in
passive mode, so that it receives route information, builds and
maintains a route table, but does not advertise or send updates on
the router port for which the entry exists."
DEFVAL { disabled }
::= { nwIpxRipIfEntry 13 }
nwIpxRipIfType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
bma(2),
nbma(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether the directly connected network segment does or
does not support broadcast media access. If broadcast media access is
supported, IPX-RIP advertisements are sent out one broadcast packet
per router port. If broadcast media access is not supported, IPX-RIP
advertisements are sent to each neighbor directly."
DEFVAL { bma }
::= { nwIpxRipIfEntry 14 }
nwIpxRipIfXmitCost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object does not apply to this protocol. It is a common object,
inherited from the common MIB framework used to provide a common
management interface to all the Cabletron Routing Services
protocol-specific MIBs. Setting this object has no effect."
DEFVAL { 0 }
::= { nwIpxRipIfEntry 15 }
nwIpxRipIfAclIdentifier OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the Access Control ID of the access control list in effect
for IPX-RIP routing protocol packets on the router port for which the
entry exists. A value of 0 indicates that there is no access control
list in effect for IPX-RIP routing protocol packets on the router
port."
DEFVAL { 0 }
::= { nwIpxRipIfEntry 16 }
nwIpxRipIfAclStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls the operation of the access control list identified by
nwIpxRipIfAclIdentifier. Enabled (3) applies the access control list
to all IPX-RIP routing protocol packet traffic on the router port for
which the entry exists. Disabled (2) prevents the access control list
from being applied. "
DEFVAL { disabled }
::= { nwIpxRipIfEntry 17 }
-- IPX RIP Interface Counters Table
-- This table contains the managed objects for IPX RIP packet and byte
-- counter on a per router port basis.
nwIpxRipIfCtrTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxRipIfCtrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains an entry for each router port.This table is
indexed by nwIpxRipIfCtrIfIndex, which indicates the value of MIB2
ifindex, which indentifies the router port for which the entry exists."
::= { nwIpxRipIfCounters 1 }
nwIpxRipIfCtrEntry OBJECT-TYPE
SYNTAX NwIpxRipIfCtrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry indicates the current packet and byte count of IPX-RIP
routing protocol packets on the router port for which the entry
exists."
INDEX { nwIpxRipIfCtrIfIndex }
::= { nwIpxRipIfCtrTable 1 }
NwIpxRipIfCtrEntry ::=
SEQUENCE {
nwIpxRipIfCtrIfIndex INTEGER,
nwIpxRipIfCtrAdminStatus INTEGER,
nwIpxRipIfCtrReset INTEGER,
nwIpxRipIfCtrOperationalTime TimeTicks,
nwIpxRipIfCtrInPkts Counter,
nwIpxRipIfCtrOutPkts Counter,
nwIpxRipIfCtrFilteredPkts Counter,
nwIpxRipIfCtrDiscardPkts Counter,
nwIpxRipIfCtrInBytes Counter,
nwIpxRipIfCtrOutBytes Counter,
nwIpxRipIfCtrFilteredBytes Counter,
nwIpxRipIfCtrDiscardBytes Counter
}
nwIpxRipIfCtrIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the value of MIB 2 ifindex, which identifies the router
port for which the entry exists."
::= { nwIpxRipIfCtrEntry 1 }
nwIpxRipIfCtrAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the per-port IPX-RIP packet and
byte counters on the router port for which the entry exists.
Enabled (3) causes these counters to become active. Disabled (2)
causes these counters to become inactive."
DEFVAL { enabled }
::= { nwIpxRipIfCtrEntry 2 }
nwIpxRipIfCtrReset OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the per-port IPX-RIP packet and byte counters on the router
port for which this entry exists. Reset (2) resets the counters to 0.
nwIpxRipIfCtrOperationalTime is also reset to 0."
::= { nwIpxRipIfCtrEntry 3 }
nwIpxRipIfCtrOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the elapsed time, in hundredths of a second, that
nwIpRipIfCtrAdminStatus has been in the current state."
::= { nwIpxRipIfCtrEntry 4 }
nwIpxRipIfCtrInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX-RIP routing protocol packets that
have been received, during nwIpxRipIfCtrOperationalTime, on the router
port for which the entry exists."
::= { nwIpxRipIfCtrEntry 5 }
nwIpxRipIfCtrOutPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX-RIP routing protocol packets that
have been transmitted, during nwIpxRipIfCtrOperationalTime, on the
router port for which the entry exists."
::= { nwIpxRipIfCtrEntry 6 }
nwIpxRipIfCtrFilteredPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX-RIP routing protocol packets that
have been administratively filtered, during
nwIpxRipIfCtrOperationalTime, on the router port for which the entry
exists."
::= { nwIpxRipIfCtrEntry 7 }
nwIpxRipIfCtrDiscardPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX-RIP routing protocol packets that
have been discarded, during nwIpxRipIfCtrOperationalTime, that were
received on the router port for which the entry exists."
::= { nwIpxRipIfCtrEntry 8 }
nwIpxRipIfCtrInBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX-RIP routing protocol
packets that have been received, during nwIpxRipIfCtrOperationalTime,
on the router port for which the entry exists."
::= { nwIpxRipIfCtrEntry 9 }
nwIpxRipIfCtrOutBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX-RIP routing protocol
packets that have been transmitted, during
nwIpxRipIfCtrOperationalTime, on the router port for which the entry
exists."
::= { nwIpxRipIfCtrEntry 10 }
nwIpxRipIfCtrFilteredBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX-RIP routing protocol
packets that have been administratively filtered, during
nwIpxRipIfCtrOperationalTime, on the router port for which the entry
exists."
::= { nwIpxRipIfCtrEntry 11 }
nwIpxRipIfCtrDiscardBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX-RIP routing protocol
packets that have been discarded, during nwIpRipIfCtrOperationalTime,
that were received on the router port for which the entry exists."
::= { nwIpxRipIfCtrEntry 12 }
-- IPX RIP Routing Table
-- This table contains the managed objects for IPX RIP route table.
nwIpxRipRouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxRipRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the IPX-RIP route table. This table contains an
entry for each route learned through the IPX-RIP routing protocol.
Only the best routes from this table are added to the IPX forwarding
table to be used for packet switching."
::= { nwIpxRipDatabase 1 }
nwIpxRipRouteEntry OBJECT-TYPE
SYNTAX NwIpxRipRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry describes the IPX-RIP route to the destination network
for which the entry exists."
INDEX { nwIpxRipRtNetId, nwIpxRipRtIfIndex, nwIpxRipRtSrcNode }
::= { nwIpxRipRouteTable 1 }
NwIpxRipRouteEntry ::=
SEQUENCE {
nwIpxRipRtNetId IpxAddress,
nwIpxRipRtIfIndex INTEGER,
nwIpxRipRtSrcNode IpxAddress,
nwIpxRipRtHops INTEGER,
nwIpxRipRtTicks INTEGER,
nwIpxRipRtAge INTEGER,
nwIpxRipRtType INTEGER,
nwIpxRipRtFlags INTEGER
}
nwIpxRipRtNetId OBJECT-TYPE
SYNTAX IpxAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the primary index into the IPX-RIP route table. This number
indicates the Novell Network Number of the destination for which the
entry exists. The IpxAddress consists of a network number of 4 octets"
::= { nwIpxRipRouteEntry 1 }
nwIpxRipRtIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a secondary index into the IPX-RIP route table. This number
corresponds to the value of MIB 2 ifindex, which identifies the router
port for which the entry exists."
::= { nwIpxRipRouteEntry 2 }
nwIpxRipRtSrcNode OBJECT-TYPE
SYNTAX IpxAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a secondary index into the RIP route table. This number
indicates the MAC-layer address of the source router from which this
route was learned. A value of 0.0.0.0.0.0 indicates that the source
is on the network segment directly connected to the router port,
nwIpxRipRtIfIndex."
::= { nwIpxRipRouteEntry 3 }
nwIpxRipRtHops OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of hops required to reach the destination for
which the entry exists."
::= { nwIpxRipRouteEntry 4 }
nwIpxRipRtTicks OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the amount of time (number of Time Ticks) required to
reach the destination for which the entry exists."
::= { nwIpxRipRouteEntry 5 }
nwIpxRipRtAge OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the amount of time, in seconds, since an update has been
received for the route for which the entry exists."
::= { nwIpxRipRouteEntry 6 }
nwIpxRipRtType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
invalid(2),
direct(3),
remote(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether the destination network is directly connected
through the router port specified by nwIpxRipRtIndex, or is
indirectly connected through another router, specified by
nwIpxRipRtSrcNode."
::= { nwIpxRipRouteEntry 7 }
nwIpxRipRtFlags OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specifies properties of the IPX-RIP route. The bit mask is as
follows: source-changed (1), best source (2), local-net (4),
net-down (8), update-fib-only (16)."
::= { nwIpxRipRouteEntry 8 }
-- IPX SAP System Group
-- This group contains the managed object for global, device-wide
-- IPX SAP DistanceVector based routing protocol.
-- IPX SAP System Configuration Parameters
-- This group contains the objects that pertain to the setup and
-- configuration of the IPX SAP DistanceVector based routing protocol.
nwIpxSapAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
disabled(2), -- shutdown the router
enabled(3) -- startup the router
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the SAP protocol system-wide.
Enabled (3) causes SAP to become active on all router ports
configured and enabled for IPX routing services. Disabled (2) causes
the protocol to become inactive."
DEFVAL { disabled }
::= { nwIpxSapConfig 1 }
nwIpxSapOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
disabled(2), -- not running
enabled(3), -- running
pending-disable(4), -- shut-down in progress
pending-enable(5) -- start-up in progress
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current operating condition of the SAP protocol
system-wide. The value of nwIpxSapOperStatus indicates any problem
with your SAP configuration. A value of 6 indicates that regardless
of the value of nwIpxSAPAdminStatus, the SAP protocol is not operating
because of an invalid configuration."
::= { nwIpxSapConfig 2 }
nwIpxSapAdminReset OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
reset(2) -- force a reset
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the SAP protocol. Reset (2) forces a system-wide restart of
SAP, without a graceful shutdown on any active router ports."
DEFVAL { other }
::= { nwIpxSapConfig 3 }
nwIpxSapOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the elapsed time, in hundredths of a second, that
nwIpxSapOperStatus, has been in its current state."
::= { nwIpxSapConfig 4 }
nwIpxSapVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current revision level of the SAP protocol firmware, in
textual format."
::= { nwIpxSapConfig 5 }
nwIpxSapStackSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the stack size of the SAP protocol thread. In order for a
change to this value to take effect, the protocol (nwIpxSapAdminReset),
IPX Routing Services (nwIpxSysAdminReset), or the device running
Routing Services must be reset."
DEFVAL { 4096 }
::= { nwIpxSapConfig 6 }
nwIpxSapThreadPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the run-time execution priority of the SAP protocol
thread. In order for a change to this value to take effect, SAP
(nwIpxSapAdminReset), IPX Routing Services (nwIpxAdminReset), or the
device running Routing Services must be reset."
DEFVAL { 127 }
::= { nwIpxSapConfig 7 }
nwIpxSapDatabaseThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the run-time maximum number of entries that can be held in
the SAP server table."
DEFVAL { 2000 }
::= { nwIpxSapConfig 8 }
nwIpxSapAgeOut OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the amount of time, in seconds, that an inactive server
table entry remains in the SAP server table before it is aged out."
DEFVAL { 180 }
::= { nwIpxSapConfig 9 }
nwIpxSapHoldDown OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the amount of time, in seconds, to wait before removing an
entry from the SAP server table, after receiving an update indicating
that the destination has become unreachable. All routers exchanging
SAP information must have the same hold down time. The time must be
long enough to allow all participating routers to receive the same
update."
DEFVAL { 120 }
::= { nwIpxSapConfig 10 }
-- IPX SAP System (aggregate) Counters
-- This group contains the aggregate (device-wide) IPX SAP packet and
-- byte counters.
nwIpxSapCtrAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the aggregate (system-wide) SAP
protocol packet and byte counters. Enabled (3) causes these counters
to become active on all router ports. Disabled (2) causes these
counters to become inactive."
DEFVAL { enabled }
::= { nwIpxSapCounters 1 }
nwIpxSapCtrReset OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the aggregate (system-wide) SAP protocol packet and byte
counters. Reset (2) resets the SAP aggregate counters to 0.
nwIpxSapCtrOperationalTime is also reset to 0."
DEFVAL { other }
::= { nwIpxSapCounters 2 }
nwIpxSapCtrOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the elapsed time, in hundredths of a second, that
nwIpxSapCtrAdminStatus, has been in the current state."
::= { nwIpxSapCounters 3 }
nwIpxSapCtrInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of SAP packets that have been received,
system-wide, during nwIpxSapCtrOperationalTime."
::= { nwIpxSapCounters 4 }
nwIpxSapCtrOutPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of SAP packets that have been transmitted,
system-wide, during nwIpxSapCtrOperationalTime."
::= { nwIpxSapCounters 5 }
nwIpxSapCtrFilteredPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of SAP packets that have been
administratively filtered, system-wide, during
nwIpxSapCtrOperationalTime."
::= { nwIpxSapCounters 6 }
nwIpxSapCtrDiscardPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of SAP packets that have been discarded,
system-wide, during nwIpxSapCtrOperationalTime."
::= { nwIpxSapCounters 7 }
nwIpxSapCtrInBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the SAP packets that have been
received, system-wide, during nwIpxSapCtrOperationalTime."
::= { nwIpxSapCounters 8 }
nwIpxSapCtrOutBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the SAP packets that have
been transmitted, system-wide, during nwIpxSapCtrOperationalTime."
::= { nwIpxSapCounters 9 }
nwIpxSapCtrFilteredBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the SAP packets that have
been administratively filtered, system-wide, during
nwIpxSapCtrOperationalTime."
::= { nwIpxSapCounters 10 }
nwIpxSapCtrDiscardBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the SAP packets that have
been discarded system-wide, during nwIpxSapCtrOperationalTime."
::= { nwIpxSapCounters 11 }
-- IPX SAP Interface Table
-- This table contains the managed objects used to setup and configure
-- SAP on a per router port basis.
nwIpxSapIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxSapIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains an entry for each router port. Each entry can
contain different values, allowing the SAP configuration to vary from
router port to router port. This table is indexed by nwIpxSapIfIndex,
which indicates the value of MIB 2 ifindex, which identifies the router
port for which each entry exists."
::= { nwIpxSapIfConfig 1 }
nwIpxSapIfEntry OBJECT-TYPE
SYNTAX NwIpxSapIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the SAP configuration for the router port for
which the entry exists."
INDEX { nwIpxSapIfIndex }
::= { nwIpxSapIfTable 1 }
NwIpxSapIfEntry ::=
SEQUENCE {
nwIpxSapIfIndex INTEGER,
nwIpxSapIfAdminStatus INTEGER,
nwIpxSapIfOperStatus INTEGER,
nwIpxSapIfOperationalTime TimeTicks,
nwIpxSapIfVersion INTEGER,
nwIpxSapIfAdvertisement INTEGER,
nwIpxSapIfFloodDelay INTEGER,
nwIpxSapIfRequestDelay INTEGER,
nwIpxSapIfPriority INTEGER,
nwIpxSapIfHelloTimer INTEGER,
nwIpxSapIfSplitHorizon INTEGER,
nwIpxSapIfPoisonReverse INTEGER,
nwIpxSapIfSnooping INTEGER,
nwIpxSapIfType INTEGER,
nwIpxSapIfXmitCost INTEGER,
nwIpxSapIfAclIdentifier INTEGER,
nwIpxSapIfAclStatus INTEGER
}
nwIpxSapIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the value of MIB 2 ifindex, which identifies the router
port for which the entry exists."
::= { nwIpxSapIfEntry 1 }
nwIpxSapIfAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the SAP protocol on the router port
for which the entry exists. Enabled (3) causes SAP to become active
on the router port. Disabled (2) causes SAP to become inactive."
DEFVAL { disabled }
::= { nwIpxSapIfEntry 2 }
nwIpxSapIfOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
disabled(2), -- not running
enabled(3), -- running
pending-disable(4), -- shut-down in progress
pending-enable(5) -- start-up in progress
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current operating condition of the SAP protocol on the
router port for which the entry exists. The value of
nwIpxSapIfOperStatus indicates any problem with your SAP configuration
on the router port. A value of 6 indicates that regardless of the
value of nwIpxSapIfAdminStatus. SAP is not operating because of an
invalid configuration."
::= { nwIpxSapIfEntry 3 }
nwIpxSapIfOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the elapsed time, in hundredths of a second, that
nwIpxSapIfOperStatus has been in its current state."
::= { nwIpxSapIfEntry 4 }
nwIpxSapIfVersion OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the revision level of the SAP protocol in textual format."
DEFVAL { 1 }
::= { nwIpxSapIfEntry 5 }
nwIpxSapIfAdvertisement OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the interval, in seconds, at which SAP advertises its server
table on the router port for which the entry exists. Change this value
to cause SAP to advertise its server table more or less frequently."
DEFVAL { 60 }
::= { nwIpxSapIfEntry 6 }
nwIpxSapIfFloodDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the length of time, in seconds, that the SAP protocol will
wait after discovering that a directly connected route has gone down,
before flooding updates (triggered updates) on the router port for
which the entry exists. A value of 0 specifies that if a directly
connected route goes down, updates should be sent immediately ."
DEFVAL { 2 }
::= { nwIpxSapIfEntry 7 }
nwIpxSapIfRequestDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the length of time, in seconds, that the SAP protocol will
wait after receiving a server request packet, before sending a
response on the router port for which the entry exists. A value of 0
specifies that if a server request packet is received on the port, a
response will be sent immediately."
DEFVAL { 0 }
::= { nwIpxSapIfEntry 8 }
nwIpxSapIfPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object does not apply to this protocol. It is a common object,
inherited from the MIB framework used to provide a management
interface to all the Cabletron Routing Services protocol-specific
MIBs. Setting this object has no effect."
DEFVAL { 1 }
::= { nwIpxSapIfEntry 9 }
nwIpxSapIfHelloTimer OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object does not apply to this protocol. It is a common object,
inherited from the MIB framework used to provide a management
interface to all the Cabletron Routing Services protocol-specific
MIBs.Setting this object has no effect."
DEFVAL { 10 }
::= { nwIpxSapIfEntry 10 }
nwIpxSapIfSplitHorizon OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls the operation of Split Horizon on the router port for which
the entry exists. When Split Horizon is enabled, SAP keeps track of
which router port information is received on, and prevents information
about a server from being sent back out the same router port it was
received on."
DEFVAL { enabled }
::= { nwIpxSapIfEntry 11 }
nwIpxSapIfPoisonReverse OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls the operation of Poison Reverse on the router port for
which the entry exists. When Poison Reverse is enabled, SAP
advertises any downed server as unreachable during the period of time
that it must wait (nwIpxSapIfHoldDown) before removing the server
from the server table."
DEFVAL { disabled }
::= { nwIpxSapIfEntry 12 }
nwIpxSapIfSnooping OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls the operation of SAP Snooping on the router port. When SAP
Snooping is enabled SAP operates in passive mode, so it receives
service information, builds and maintains a server table, but does
not advertise or send updates on the router port for which the entry
exists. Enabled (3) turns on SAP Snooping. Disabled (2) turns off SAP
Snooping."
DEFVAL { disabled }
::= { nwIpxSapIfEntry 13 }
nwIpxSapIfType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
bma(2),
nbma(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether the directly connected network segment does or
does not support broadcast media access. If broadcast media access is
supported, SAP advertisements are sent out, one broadcast packet per
router port. If broadcast media access is not supported, SAP
advertisements are sent to each neighbor router directly."
DEFVAL { bma }
::= { nwIpxSapIfEntry 14 }
nwIpxSapIfXmitCost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object does not apply to this protocol. It is a common object,
inherited from the MIB framework used to provide a common management
interface to all the Cabletron Routing Services protocol-specific MIBs.
Setting this object has no effect."
DEFVAL { 0 }
::= { nwIpxSapIfEntry 15 }
nwIpxSapIfAclIdentifier OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the Access Control List ID of the access control list in
effect for SAP protocol packets on the router port for which the entry
exists. A value of 0 indicates that there is no access control list
in effect for SAP protocol packets on the router port for which the
entry exists."
DEFVAL { 0 }
::= { nwIpxSapIfEntry 16 }
nwIpxSapIfAclStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls the operation of the access control list identified by
nwIpxSapIfAclIdentifier. Enabled (3) causes the access control list
to be applied to all SAP protocol packet traffic on the router port
for which the entry exists. Disabled (2) prevents the access control
list from being applied."
DEFVAL { disabled }
::= { nwIpxSapIfEntry 17 }
-- IPX SAP Interface Counters Table
-- This table contains the managed objects for IPX SAP packet and byte
-- counter on a per router port basis.
nwIpxSapIfCtrTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxSapIfCtrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains an entry for each router port. This table is
indexed by nwIpxSapIfCtrIfIndex which indicates the value of MIB2
ifindex, which indentifies the router port for which the entry
exists."
::= { nwIpxSapIfCounters 1 }
nwIpxSapIfCtrEntry OBJECT-TYPE
SYNTAX NwIpxSapIfCtrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry indicates the current packet and byte count of SAP
protocol packets on the router port for which the entry exists."
INDEX { nwIpxSapIfCtrIfIndex }
::= { nwIpxSapIfCtrTable 1 }
NwIpxSapIfCtrEntry ::=
SEQUENCE {
nwIpxSapIfCtrIfIndex INTEGER,
nwIpxSapIfCtrAdminStatus INTEGER,
nwIpxSapIfCtrReset INTEGER,
nwIpxSapIfCtrOperationalTime TimeTicks,
nwIpxSapIfCtrInPkts Counter,
nwIpxSapIfCtrOutPkts Counter,
nwIpxSapIfCtrFilteredPkts Counter,
nwIpxSapIfCtrDiscardPkts Counter,
nwIpxSapIfCtrInBytes Counter,
nwIpxSapIfCtrOutBytes Counter,
nwIpxSapIfCtrFilteredBytes Counter,
nwIpxSapIfCtrDiscardBytes Counter
}
nwIpxSapIfCtrIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the value of the MIB 2 ifindex, which identifies the router
port for which the entry exists."
::= { nwIpxSapIfCtrEntry 1 }
nwIpxSapIfCtrAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the per-port SAP packet and byte
counters on the router port for which this entry exists. Enabled (3)
causes these counters to become active. Disabled (2) causes these
counters to become inactive."
DEFVAL { enabled }
::= { nwIpxSapIfCtrEntry 2 }
nwIpxSapIfCtrReset OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the per-port SAP packet and byte counters on the router port
for which the entry exists. Reset (2) resets the counters to 0.
nwIpxSapIfCtrOperationalTime is also reset to 0."
DEFVAL { other }
::= { nwIpxSapIfCtrEntry 3 }
nwIpxSapIfCtrOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the elapsed time, in hundredths of a second, that
nwIpxSapIfCtrAdminStatus has been in the current state."
::= { nwIpxSapIfCtrEntry 4 }
nwIpxSapIfCtrInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of SAP protocol packets that have been
received, during nwIpxSapIfCtrOperationalTime, on the router port for
which the entry exists."
::= { nwIpxSapIfCtrEntry 5 }
nwIpxSapIfCtrOutPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of SAP packets that have been transmitted,
during nwIpxSapIfCtrOperationalTime, on the router port for which the
entry exists."
::= { nwIpxSapIfCtrEntry 6 }
nwIpxSapIfCtrFilteredPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of SAP packets that have been
administratively filtered, during nwIpxSapIfCtrOperationalTime, on
the router port for which the entry exists."
::= { nwIpxSapIfCtrEntry 7 }
nwIpxSapIfCtrDiscardPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of SAP packets that have been discarded,
during nwIpxSapIfCtrOperationalTime, that were received on the router
port for which the entry exists."
::= { nwIpxSapIfCtrEntry 8 }
nwIpxSapIfCtrInBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the SAP packets that have
been received, during nwIpxSapIfCtrOperationalTime, on the router port
for which the entry exists."
::= { nwIpxSapIfCtrEntry 9 }
nwIpxSapIfCtrOutBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the SAP packets that have been
transmitted, during nwIpxSapIfCtrOperationalTime, on the router port
for which the entry exists."
::= { nwIpxSapIfCtrEntry 10 }
nwIpxSapIfCtrFilteredBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the SAP packets that have been
administratively filtered, during nwIpxSapIfCtrOperationalTime, on the
router port for which the entry exists."
::= { nwIpxSapIfCtrEntry 11 }
nwIpxSapIfCtrDiscardBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the SAP packets that have
been discarded, during nwIpxSapIfCtrOperationalTime, that were
received on the router port for which the entry exists."
::= { nwIpxSapIfCtrEntry 12 }
-- IPX SAP Server table Table
-- This table contains the managed objects for IPX SAP route table.
nwIpxSapServerIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxSapServerIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table contains the SAP server table. This table contains an entry
for each service learned of through the SAP protocol."
::= { nwIpxSapServerTable 1 }
nwIpxSapServerIfEntry OBJECT-TYPE
SYNTAX NwIpxSapServerIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the SAP route information for the Novell server
and router port for which the entry exists."
INDEX { nwIpxSapServerIfNetId, nwIpxSapServerIfNode,
nwIpxSapServerIfSocket, nwIpxSapServerIfServiceType,
nwIpxSapServerIfIfNum, nwIpxSapServerIfSrcNode }
::= { nwIpxSapServerIfTable 1 }
NwIpxSapServerIfEntry ::=
SEQUENCE {
nwIpxSapServerIfNetId IpxAddress,
nwIpxSapServerIfNode OCTET STRING,
nwIpxSapServerIfSocket OCTET STRING,
nwIpxSapServerIfServiceType INTEGER,
nwIpxSapServerIfIfNum INTEGER,
nwIpxSapServerIfSrcNode OCTET STRING,
nwIpxSapServerIfName OCTET STRING,
nwIpxSapServerIfHops INTEGER,
nwIpxSapServerIfAge INTEGER,
nwIpxSapServerIfType INTEGER,
nwIpxSapServerIfFlags INTEGER
}
nwIpxSapServerIfNetId OBJECT-TYPE
SYNTAX IpxAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the primary index into the SAP server table. This number
corresponds to the Novell Network Number of the server offering the
service. The network number consists of 4 octets."
::= { nwIpxSapServerIfEntry 1 }
nwIpxSapServerIfNode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a secondary index into the SAP Server Table. This is the
MAC-layer address represented as an octetstring of the service
offering the server for which the entry exists, represented as an
octet string."
::= { nwIpxSapServerIfEntry 2 }
nwIpxSapServerIfSocket OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a secondary index into the SAP Server Table. This is the
socket number of the server application for which the entry exists."
::= { nwIpxSapServerIfEntry 3 }
nwIpxSapServerIfServiceType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a secondary index into the SAP Server Table. This is the
service type of the server application for which the entry exists."
::= { nwIpxSapServerIfEntry 4 }
nwIpxSapServerIfIfNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the value of MIB 2 ifindex, which identifies the router
port through which the service for which the entry exits is available."
::= { nwIpxSapServerIfEntry 5 }
nwIpxSapServerIfSrcNode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the MAC-layer address of the neighbor router from which the
service was learned about."
::= { nwIpxSapServerIfEntry 6 }
nwIpxSapServerIfName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the name of the server offering the service for which the
entry exists."
::= { nwIpxSapServerIfEntry 7 }
nwIpxSapServerIfHops OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of hops required to reach the server offering
the service for which the entry exists."
::= { nwIpxSapServerIfEntry 8 }
nwIpxSapServerIfAge OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the amount of time since a SAP update was last received
for the server and service for which the entry exits."
::= { nwIpxSapServerIfEntry 9 }
nwIpxSapServerIfType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
invalid(2),
direct(3),
remote(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether the server is on a network that is directly
connected through the router port for which the entry exists, or is
indirectly connected through another router specified by the value of
nwIpxSapServerIfSrcNode."
::= { nwIpxSapServerIfEntry 10 }
nwIpxSapServerIfFlags OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specifies properties of the SAP service for which the entry exist.
The bit mask is as follows: source-changed (1), best-source (2), not
used (4), net-down (8), not used (16)."
::= { nwIpxSapServerIfEntry 11 }
-- IPX Forward Information Base (FIB) Table
-- This table contains the managed objects for the forwarding table of the
-- IPX router. This table is built from entries in the IPX routing table(s)
-- and reflects the routes that are considered the best routes to forward on.
nwIpxFibTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxFibEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains an entry describing each route being used to
forward IPX traffic to each destination Novell network and node."
::= { nwIpxFib 1 }
nwIpxFibEntry OBJECT-TYPE
SYNTAX NwIpxFibEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry describes the route to the destination Novell network and
node for which the entry exists."
INDEX { nwIpxFibNetId }
::= { nwIpxFibTable 1 }
NwIpxFibEntry ::=
SEQUENCE {
nwIpxFibNetId IpxAddress,
nwIpxFibHops INTEGER,
nwIpxFibTimeTicks TimeTicks,
nwIpxFibNextHopIf INTEGER,
nwIpxFibNextHopNet OCTET STRING,
nwIpxFibNextHopNode MacAddress,
nwIpxFibRouteType INTEGER
}
nwIpxFibNetId OBJECT-TYPE
SYNTAX IpxAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specifies the Novell Network Number of the destination for which the
entry exists. The IpxAddress consists of four octets"
::= { nwIpxFibEntry 1 }
nwIpxFibHops OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the number of hops required to reach the destination for
which the entry exists. It is considered as metric 1."
DEFVAL { 0 }
::= { nwIpxFibEntry 2 }
nwIpxFibTimeTicks OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the amount of time, indicated by the number of TimeTicks,
required for a packet to reach the destination network for which the
entry exists. It is considered as metric 2."
DEFVAL { 0 }
::= { nwIpxFibEntry 3 }
nwIpxFibNextHopIf OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the router port through which the next hop node is
available. Packets destined for the network specified by the value of
nwIpxFibNetId will be forwarded on this port."
::= { nwIpxFibEntry 4 }
nwIpxFibNextHopNet OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the Novell Network Number portion of the fully formed next
hop IPX Address of the next hop node."
::= { nwIpxFibEntry 5 }
nwIpxFibNextHopNode OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the node portion of the fully formed next hop IPX Address."
::= { nwIpxFibEntry 6 }
nwIpxFibRouteType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
invalid(2),
direct(3),
remote(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the status of the route. A value of 3 indicates that the
destination is on the network segment that is directly connected to
the router port identified by nwIpxFibNextHopIf. A value of 4 indicates
that the destination is on an indirectly connected network segment,
which is reachable through the next hop router indicated by the value
of nwIpxFibNextHopNodeId. A value of 2 indicates that the route is
invalid."
DEFVAL { direct }
::= { nwIpxFibEntry 7 }
-- IPX Access Control List Table
-- This table contains the managed objects for the Access Control Lists
-- within the IPX Router. Access Control Lists allow configuration of
-- restricted access to networks and protocols reachable thru the IPX
-- Router device. Access Control Lists can be defined with these
nwIpxAclValidEntries OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of valid entries that exist in the access control
list table."
::= { nwIpxAccessControl 1 }
nwIpxAclTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxAclEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the access control list information for IPX
traffic. This table contains entries, each of which allows packet
forwarding between source/destination pairs to be permitted or denied.
The list is identified by the Access Control List ID. Each list may
contain multiple entries ordered by sequence number. When a particular
access control list is searched, it is searched in sequence number
order and the first match found ends the search. If no match if found,
access defaults to permitted."
::= { nwIpxAccessControl 2 }
nwIpxAclEntry OBJECT-TYPE
SYNTAX NwIpxAclEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains IPX source/destination access information."
INDEX { nwIpxAclIdentifier, nwIpxAclSequence }
::= { nwIpxAclTable 1 }
NwIpxAclEntry ::=
SEQUENCE {
nwIpxAclIdentifier INTEGER,
nwIpxAclSequence INTEGER,
nwIpxAclPermission INTEGER,
nwIpxAclMatches Counter,
nwIpxAclDestNetNum OCTET STRING,
nwIpxAclDestNode OCTET STRING,
nwIpxAclDestSocket OCTET STRING,
nwIpxAclSrcNetNum OCTET STRING,
nwIpxAclSrcNode OCTET STRING,
nwIpxAclSrcSocket OCTET STRING
}
nwIpxAclIdentifier OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the primary (major) index into the IPX access control list
table. This value identifies the access control list by a unique
identifier (at least 1) arbitrarily assigned by the user. All entries
that have the same value for nwIpxAclIdentifier belong to the same
access control list."
::= { nwIpxAclEntry 1 }
nwIpxAclSequence OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the secondary (minor) index into the IPX access control list
table. This number corresponds to a sequence number used to order
multiple entries within the same access control list."
::= { nwIpxAclEntry 2 }
nwIpxAclPermission OBJECT-TYPE
SYNTAX INTEGER {
other(1),
invalid(2),
permit(3),
deny(4),
permit-bidirectional(5),
deny-bidirectional(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies whether access is allowed or denied between the source and
destination address pair. Note that source and destination are
interchangeable when bi-directional control is selected. To remove an
existing entry set nwIpxAclPermission to invalid (2). Invalid entries
disappear after reboot."
DEFVAL { permit }
::= { nwIpxAclEntry 3 }
nwIpxAclMatches OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the number of matches on this entry that have resulted in
the permit/deny access restriction being applied as part of the
forwarding process."
::= { nwIpxAclEntry 4 }
nwIpxAclDestNetNum OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the destination Novell Network Number used to compare for
matches on the access control list. A 0 value is a wildcard which
matches any Novell Network Number."
::= { nwIpxAclEntry 5 }
nwIpxAclDestNode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the MAC-layer address of the destination node (represented
as an octet string), used to compare for matches on the access control
list. A value 0 is a wildcard, which matches any node."
::= { nwIpxAclEntry 6 }
nwIpxAclDestSocket OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the socket number of the destination socket used to compare
for matches on the access control list. A 0 value is a wildcard
matching any socket."
::= { nwIpxAclEntry 7 }
nwIpxAclSrcNetNum OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the Novell Network Number of the source Novell Network used
to compare for matches on the access control list. A 0 value is a
wildcard matching any Novell Network Number."
::= { nwIpxAclEntry 8 }
nwIpxAclSrcNode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the MAC-layer address of the source node (represented as an
octet string), used to compare for matches on the Access Control
List. A 0 value is a wildcard matching any node."
::= { nwIpxAclEntry 9 }
nwIpxAclSrcSocket OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the socket number of the source socket to compare for
matches on the Access Control List. A 0 value is a wildcard matching
any socket."
::= { nwIpxAclEntry 10 }
-- IPX Redirector Group
-- IPX NetBIOS System Group
-- In order for NetBIOS to function, an IPX routing service is provided
-- which allows NetBIOS traffic to be flooded out all router ports with
-- NetBIOS enabled.
nwIpxNetBIOSAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the NetBIOS Broadcast Redirector,
system-wide. Enabled (3) causes the NetBios Broadcast Redirector to
become active on any router port configured and enabled for IPX
Routing Services. Disabled (2) causes the NetBIOS Broadcast Redirector
to perform a graceful shut-down on any active IPX router port."
DEFVAL { disabled }
::= { nwIpxNetBIOSConfig 1 }
nwIpxNetBIOSOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
disabled(2), -- not running
enabled(3), -- running
pending-disable(4), -- shut-down in progress
pending-enable(5), -- start-up in progress
invalid-config(6) -- not running,invalid config
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current operating condition of the NetBIOS Broadcast
Redirector, system-wide. "
::= { nwIpxNetBIOSConfig 2 }
nwIpxNetBIOSAdminReset OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
reset(2) -- force a reset
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the NetBIOS Broadcast Redirector, system-wide. Reset (2)
forces a restart of the NetBIOS Broadcast Redirector without a
graceful shut-down on any active router port and without effecting any
other router application."
DEFVAL { other }
::= { nwIpxNetBIOSConfig 3 }
nwIpxNetBIOSOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the elapsed time, in hundredths of a second, that
nwIpxNetBiosOperStatus has been in the current state."
::= { nwIpxNetBIOSConfig 4 }
nwIpxNetBIOSVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current revision level of the NetBIOS Broadcast
Redirector firmware, in textual format."
::= { nwIpxNetBIOSConfig 5 }
-- IPX NetBIOS System (aggregate) Counters
-- This group contains the aggregate (device-wide) IPX NetBIOS packet
-- and byte counters.
nwIpxNetBIOSCtrAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the aggregate (system-wide) NetBIOS
broadcast packet and byte counters. Enabled (3) causes these counters
to become active on all router port. Disabled (2) causes these
counters to become inactive."
::= { nwIpxNetBIOSCounters 1 }
nwIpxNetBIOSCtrReset OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the aggregate (system-wide) NetBIOS broadcast packet and byte
counters. Reset (2) resets the NetBIOS broadcast aggregate counters
to 0. nwIpxNetBIOSCtrOperationalTime is also reset to 0."
::= { nwIpxNetBIOSCounters 2 }
nwIpxNetBIOSCtrOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the elapsed time, in hundreds of a second, that the
nwIpxNetBIOSCtrAdminStatus has been in the current state."
::= { nwIpxNetBIOSCounters 3 }
nwIpxNetBIOSCtrInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of NetBIOS broadcast packets that have
been received, system-wide, during nwIpxNetBIOSCtrOperationalTime."
::= { nwIpxNetBIOSCounters 4 }
nwIpxNetBIOSCtrOutPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of NetBIOS broadcast packets that have
been transmitted, system-wide, during nwIpxNetBIOSCtrOperationalTime."
::= { nwIpxNetBIOSCounters 5 }
nwIpxNetBIOSCtrFilteredPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of NetBIOS broadcast packets that have
been administratively filtered, system-wide, during
nwIpxNetBIOSCtrOperationalTime."
::= { nwIpxNetBIOSCounters 6 }
nwIpxNetBIOSCtrDiscardPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of NetBIOS broadcast packets that have
been discarded, system-wide, during nwIpxNetBIOSCtrOperationalTime."
::= { nwIpxNetBIOSCounters 7 }
nwIpxNetBIOSCtrInBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the NetBIOS packets that have
been received, system-wide, during nwIpxNetBIOSCtrOperationalTime."
::= { nwIpxNetBIOSCounters 8 }
nwIpxNetBIOSCtrOutBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the NetBIOS packets that have
been transmitted, system-wide, during nwIpxNetBIOSCtrOperationalTime."
::= { nwIpxNetBIOSCounters 9 }
nwIpxNetBIOSCtrFilteredBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the NetBIOS packets that have
been administratively filtered, system-wide, during
nwIpxNetBIOSCtrOperationalTime."
::= { nwIpxNetBIOSCounters 10 }
nwIpxNetBIOSCtrDiscardBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the NetBIOS packets that have
been discarded, system-wide, during nwIpxNetBIOSCtrOperationalTime."
::= { nwIpxNetBIOSCounters 11 }
-- IPX NetBIOS Interface Table
-- This table contains the managed objects used to setup and configure
-- NetBIOS on a per router port basis.
nwIpxNetBIOSIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxNetBIOSIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains an entry for each router port. Each entry can
contain different values, allowing the NetBIOS Broadcast Redirector
configuration to vary from router port to router port. This table is
indexed by nwIpxNetBIOSIfIndex, which indicates the value of MIB 2
ifindex, which identifies the router port for which the entry exists."
::= { nwIpxNetBIOSIfConfig 1 }
nwIpxNetBIOSIfEntry OBJECT-TYPE
SYNTAX NwIpxNetBIOSIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the IPX NetBIOS broadcasting configuration for
the router port for which the entry exists." INDEX { nwIpxNetBIOSIfIndex }
::= { nwIpxNetBIOSIfTable 1 }
NwIpxNetBIOSIfEntry ::=
SEQUENCE {
nwIpxNetBIOSIfIndex INTEGER,
nwIpxNetBIOSIfAdminStatus INTEGER,
nwIpxNetBIOSIfOperStatus INTEGER,
nwIpxNetBIOSIfOperationalTime TimeTicks
}
nwIpxNetBIOSIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the value in MIB 2 ifindex, which identifies the router
port for which the entry exists."
::= { nwIpxNetBIOSIfEntry 1 }
nwIpxNetBIOSIfAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of IPX NetBIOS broadcasting on the
router port for which the entry exists. Enabled (3) causes this
router port to become active. Disabled (2) causes it to become
inactive."
DEFVAL { disabled }
::= { nwIpxNetBIOSIfEntry 2 }
nwIpxNetBIOSIfOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
disabled(2), -- not running
enabled(3), -- running
pending-disable(4), -- shut-down in progress
pending-enable(5), -- start-up in progress
invalid-config(6) -- not running,invalid config
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current operating condition of IPX NetBIOS
broadcasting on the IPX router port for which the entry exists."
::= { nwIpxNetBIOSIfEntry 3 }
nwIpxNetBIOSIfOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the elapsed time, in hundredths of a second, that IPX
NetBIOS broadcasting, nwIpxNetBIOSIfOperStatus, has been in its
current state on the router port for which the entry exists."
::= { nwIpxNetBIOSIfEntry 4 }
-- IPX NetBIOS Interface Counters Table
-- This table contains the managed objects for IPX NetBIOS packet and
-- byte counter on a per router port basis
nwIpxNetBIOSIfCtrTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxNetBIOSIfCtrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the IPX NetBIOS packet and byte counters for each
router port on this device."
::= { nwIpxNetBIOSIfCounters 1 }
nwIpxNetBIOSIfCtrEntry OBJECT-TYPE
SYNTAX NwIpxNetBIOSIfCtrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This is the primary index into the NetBIOS Interface Counter Table.
This number corresponds to the index into the MIB 2 Interface Table
which describes the router port for which this entry exists."
INDEX { nwIpxNetBIOSIfCtrIfIndex }
::= { nwIpxNetBIOSIfCtrTable 1 }
NwIpxNetBIOSIfCtrEntry ::=
SEQUENCE {
nwIpxNetBIOSIfCtrIfIndex INTEGER,
nwIpxNetBIOSIfCtrAdminStatus INTEGER,
nwIpxNetBIOSIfCtrReset INTEGER,
nwIpxNetBIOSIfCtrOperationalTime TimeTicks,
nwIpxNetBIOSIfCtrInPkts Counter,
nwIpxNetBIOSIfCtrOutPkts Counter,
nwIpxNetBIOSIfCtrFilteredPkts Counter,
nwIpxNetBIOSIfCtrDiscardPkts Counter,
nwIpxNetBIOSIfCtrInBytes Counter,
nwIpxNetBIOSIfCtrOutBytes Counter,
nwIpxNetBIOSIfCtrFilteredBytes Counter,
nwIpxNetBIOSIfCtrDiscardBytes Counter
}
nwIpxNetBIOSIfCtrIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the primary index into the IPX NetBIOS Interface Counter Table.
This number correspoonds to the index into the MIB 2 Interface Table
which describes the router port for which the entry exists."
::= { nwIpxNetBIOSIfCtrEntry 1 }
nwIpxNetBIOSIfCtrAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the IPX NetBIOS packet and bytes
counters on the IPX router port for which the entry exists. Enabled (3)
causes these counters to become active on the configured NetBIOS router
port. Disabled (2) causes thes counters to become inactive on the
configured NetBIOS router port."
::= { nwIpxNetBIOSIfCtrEntry 2 }
nwIpxNetBIOSIfCtrReset OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the NetBIOS packet and bvyte counters on the router port for
which the entry exists. Reset (2) resets the interface-specific
counters to 0. nwIpxNetBIOSIfCtrOperationalTime is also reset to 0."
::= { nwIpxNetBIOSIfCtrEntry 3 }
nwIpxNetBIOSIfCtrOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the amount of time, in hundredths of a second, that the
interface-specific NetBIOS packet and byte counters have been active on
the router port for which the entry exists."
::= { nwIpxNetBIOSIfCtrEntry 4 }
nwIpxNetBIOSIfCtrInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of NetBIOS packets that have been recieved,
on the router port for which the entry exists, during
nwIpxNetBIOSIfCtrOperationalTime."
::= { nwIpxNetBIOSIfCtrEntry 5 }
nwIpxNetBIOSIfCtrOutPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of NetBIOS packets that have been
transmitted, on the router port for which the entry exists, during
nwIpxNetBIOSIfCtrOperationallTime."
::= { nwIpxNetBIOSIfCtrEntry 6 }
nwIpxNetBIOSIfCtrFilteredPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of NetBIOS packets that have been
administratively filtered, on the router port for which the entry
exists, during nwIpxNetBIOSIfCtrOperationalTime."
::= { nwIpxNetBIOSIfCtrEntry 7 }
nwIpxNetBIOSIfCtrDiscardPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of NetBIOS packets that have been discarded,
on the router port for which the entry exists, during
nwIpxNetBIOSIfCtrOperationalTime."
::= { nwIpxNetBIOSIfCtrEntry 8 }
nwIpxNetBIOSIfCtrInBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the NetBIOS packets that have
been recieved, on the router port for which the entry exists, during
nwIpxNetBIOSIfCtrOperationalTime."
::= { nwIpxNetBIOSIfCtrEntry 9 }
nwIpxNetBIOSIfCtrOutBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the NetBIOS packets that have
been transmitted, on the router port for which the entry exists, during
nwIpxNetBIOSIfCtrOperationalTime."
::= { nwIpxNetBIOSIfCtrEntry 10 }
nwIpxNetBIOSIfCtrFilteredBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the NetBIOS packets that have
been administratively filtered, that were recieved on the router port
for which the entry exists during nwIpxNetBIOSIfCtrOperationalTime."
::= { nwIpxNetBIOSIfCtrEntry 11 }
nwIpxNetBIOSIfCtrDiscardBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the NetBIOS packets that have
been discarded, on the router port for which the entry exists, during
nwIpxNetBIOSIfCtrOperationalTime."
::= { nwIpxNetBIOSIfCtrEntry 12 }
-- IPX Broadcast System Group
-- IPX Broadcast support allows broadcast packets that would normally be
-- delivered to the host to also be switched out the proper router port
-- if that router port has broadcast enabled. The router port is determined
-- by the destination network number in the broadcast packet.
nwIpxBcastAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
disabled(2), -- shutdown the router
enabled(3) -- startup the router
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of IPX Broadcast. Enabled (3) casuses
IPX Broadcast to become active on any configured IPX router port.
Disabled (2) causes IPX Broadcast to perform a graceful shutdown on
any active IPX router ports."
DEFVAL { disabled }
::= { nwIpxBroadcastConfig 1 }
nwIpxBcastOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
disabled(2), -- not running
enabled(3), -- running
pending-disable(4), -- shut-down in progress
pending-enable(5), -- start-up in progress
invalid-config(6) -- not running,invalid config
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current operating condition of the IPX Broadcast."
::= { nwIpxBroadcastConfig 2 }
nwIpxBcastAdminReset OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
reset(2) -- force a reset
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the IPX Broadcast. Reset (2) will force a restart of the IPX
Broadcast without a graceful shutdown on any active IPX router port,
without effecting any other router applications."
DEFVAL { other }
::= { nwIpxBroadcastConfig 3 }
nwIpxBcastOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the amount of time, in hundredths of a second, that IPX
Broadcast has been in its current operational state."
::= { nwIpxBroadcastConfig 4 }
nwIpxBcastVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current revision level of IPX Broadcast."
::= { nwIpxBroadcastConfig 5 }
-- IPX Broadcast System (aggregate) Counters
-- This group contains the aggregate (device-wide) IPX Broadcast packet
-- and byte counters.
nwIpxBcastCtrAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the aggregate (device-wide) Broadcast packet and byte counters. enable (3) causes these counters
to become active on any router port running Broadcast. disabled (2)
causes these counters to become inactive on all router port
running Broadcast."
::= { nwIpxBroadcastCounters 1 }
nwIpxBcastCtrReset OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the aggregate (device-wide) IPX Broadcast packet and byte
counters. Reset (2) resets the IPX Broadcast aggregate counters to 0.
nwIpxBcasstCtrOperationalTime is also reset to 0."
::= { nwIpxBroadcastCounters 2 }
nwIpxBcastCtrOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the amount of time, in hundredths of a second, that the
aggregate (device-wide) IPX Broadcast packet and byte counters have been
in the current administrative state."
::= { nwIpxBroadcastCounters 3 }
nwIpxBcastCtrInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Broadcast packets that have been
received, device-wide, during nwIpxBcastCtrOperationalTime."
::= { nwIpxBroadcastCounters 4 }
nwIpxBcastCtrOutPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Broadcast packets that have been
transmitted, device-wide, during nwIpxBcastCtrOperationalTime."
::= { nwIpxBroadcastCounters 5 }
nwIpxBcastCtrFilteredPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Broadcast packets that have been
administaratively filtered, device-wide, during
nwIpxBcastCtrOperationalTime."
::= { nwIpxBroadcastCounters 6 }
nwIpxBcastCtrDiscardPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Broadcast packets that have been
discarded, device-wide, during nwIpxBcastCtrOperationalTime."
::= { nwIpxBroadcastCounters 7 }
nwIpxBcastCtrInBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Broadcast packets that have been
recieved, device-wide, during nwIpxBcastCtrOperationalTime."
::= { nwIpxBroadcastCounters 8 }
nwIpxBcastCtrOutBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Broadcast packets that have been
transmitted, device-wide, during nwIpxBcastCtrOperationalTime."
::= { nwIpxBroadcastCounters 9 }
nwIpxBcastCtrFilteredBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX Broadcast packets that
have been administratively filtered, device-wide, during
nwIpxBcastOperationalTime."
::= { nwIpxBroadcastCounters 10 }
nwIpxBcastCtrDiscardBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the Broadcast packets that
have been discarded, during nwIpxBcastCtrOperationalTime."
::= { nwIpxBroadcastCounters 11 }
-- IPX Broadcast Interface Table
-- This table contains the managed objects used to setup and configure
-- Broadcast on a per router port basis.
nwIpxBcastIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxBcastIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains an entry for each router port configured for the
IPX distance-vector based routing protocol. Each entry can contain
different values, allowing the routing protocol configuration to
vary from router port to router port. This table is indexed by
nwIpxBcastIfIndex, which indicates the value of MIB 2 ifindex, which
identifies the router port for which the entry exists."
::= { nwIpxBroadcastIfConfig 1 }
nwIpxBcastIfEntry OBJECT-TYPE
SYNTAX NwIpxBcastIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the IPX Broadcast configuration information for the
logical IPX interface for which this entry exists."
INDEX { nwIpxBcastIfIndex }
::= { nwIpxBcastIfTable 1 }
NwIpxBcastIfEntry ::=
SEQUENCE {
nwIpxBcastIfIndex INTEGER,
nwIpxBcastIfAdminStatus INTEGER,
nwIpxBcastIfOperStatus INTEGER,
nwIpxBcastIfOperationalTime TimeTicks
}
nwIpxBcastIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This index corresponds to the primary index into the MIB 2 Interface
Table, which describes the router port for which the entry exists."
::= { nwIpxBcastIfEntry 1 }
nwIpxBcastIfAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the IPX Broadcast on the router
port for which the entry exists. Enabled (2) causes IPX Broadcast on
this router port to become active. Disabled (2) causes IPX Broadcast
to become inactive."
DEFVAL { disabled }
::= { nwIpxBcastIfEntry 2 }
nwIpxBcastIfOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
disabled(2), -- not running
enabled(3), -- running
pending-disable(4), -- shut-down in progress
pending-enable(5), -- start-up in progress
invalid-config(6) -- not running,invalid config
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current operating condition of the IPX Broadcast on
the router port for which the entry exists."
::= { nwIpxBcastIfEntry 3 }
nwIpxBcastIfOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the elapsed time, in hundredths of a second, that
nwIPXBcastIfOperStatus has been in its current state."
::= { nwIpxBcastIfEntry 4 }
-- IPX Broadcast Interface Counters Table
-- This table contains the managed objects for IPX Broadcast packet and
-- byte counter on a per router port basis.
nwIpxBcastIfCtrTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxBcastIfCtrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the IPX Broadcast packet and byte counters for each
router port on this device."
::= { nwIpxBroadcastIfCounters 1 }
nwIpxBcastIfCtrEntry OBJECT-TYPE
SYNTAX NwIpxBcastIfCtrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This is the primary index into the Broadcast Interface Counter Table.
This number corresponds to the index into the MIB 2 Interface Table
which describes the router port for which the entry exists."
INDEX { nwIpxBcastIfCtrIfIndex }
::= { nwIpxBcastIfCtrTable 1 }
NwIpxBcastIfCtrEntry ::=
SEQUENCE {
nwIpxBcastIfCtrIfIndex INTEGER,
nwIpxBcastIfCtrAdminStatus INTEGER,
nwIpxBcastIfCtrReset INTEGER,
nwIpxBcastIfCtrOperationalTime TimeTicks,
nwIpxBcastIfCtrInPkts Counter,
nwIpxBcastIfCtrOutPkts Counter,
nwIpxBcastIfCtrFilteredPkts Counter,
nwIpxBcastIfCtrDiscardPkts Counter,
nwIpxBcastIfCtrInBytes Counter,
nwIpxBcastIfCtrOutBytes Counter,
nwIpxBcastIfCtrFilteredBytes Counter,
nwIpxBcastIfCtrDiscardBytes Counter
}
nwIpxBcastIfCtrIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the primary index into the IPX Broadcast Interface Counter
Table. This number corresponds to the index into the MIB 2 Interface
Table which describes the router port for which the entry exists."
::= { nwIpxBcastIfCtrEntry 1 }
nwIpxBcastIfCtrAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the IPX Broadcast packet and byte
counters on the router port for which the entry exists. Enabled (3)
causes these counters to become acive on the configured IPX Broadcast
router port. Disabled (2) causes these counters to become inactive on
the configured IPX Broadcast router port."
::= { nwIpxBcastIfCtrEntry 2 }
nwIpxBcastIfCtrReset OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the IPX Broadcast packet and byte counters on the router port for
which the entry exists. Reset (2) resets the interface-specific counters
to 0. nwIpxBcastIfCtrOperationalTime is also reset to 0."
::= { nwIpxBcastIfCtrEntry 3 }
nwIpxBcastIfCtrOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the amount of time, in hundredths of a second, that the
interface-specific IPX Broadcast packet and byte counters have been in
the current administrative state on the router port for which the entry
exists."
::= { nwIpxBcastIfCtrEntry 4 }
nwIpxBcastIfCtrInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Broadcast packets that have been
recieved, on the router port for which the entry exists, during
nwIpxBcastIfCtrOperationalTime."
::= { nwIpxBcastIfCtrEntry 5 }
nwIpxBcastIfCtrOutPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of Broadcast packets that have been
transmitted, on the router port for which the entry existsl, during
nwIpxBcastIfCtrOperationalTime."
::= { nwIpxBcastIfCtrEntry 6 }
nwIpxBcastIfCtrFilteredPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Broadcast packets that have been
administratively filtered, on the router port for which the entry
exists, during nwIpxBcastIfCtrOperationalTime."
::= { nwIpxBcastIfCtrEntry 7 }
nwIpxBcastIfCtrDiscardPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of Broadcast packets that have been dis-
carded, on the router port for which the entry exists, during
nwIpxBcastIfCtrOperationalTime."
::= { nwIpxBcastIfCtrEntry 8 }
nwIpxBcastIfCtrInBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX Broadcast packets that
have been recieved, on the router port for which the entry exists,
during nwIpxBcastIfCtrOperationalTime."
::= { nwIpxBcastIfCtrEntry 9 }
nwIpxBcastIfCtrOutBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX Broadcast packets that
have been transmitted, on the router port for which the entry exists,
during nwIpxBcastIfCtrOperationalTime."
::= { nwIpxBcastIfCtrEntry 10 }
nwIpxBcastIfCtrFilteredBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX Broadcast packets that
have been administratively filtered on the router port for which the
entry exists during nwIpxBcastIfCtrOperationalTime."
::= { nwIpxBcastIfCtrEntry 11 }
nwIpxBcastIfCtrDiscardBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX Broadcast packets that
have been discarded on the router port for which the entry exists,
during nwIpxBcastIfCtrOperationalTime."
::= { nwIpxBcastIfCtrEntry 12 }
-- IPX Echo System Group
-- Echo messages provide the ability to check for host reachability and
-- network connectivity. If the router receives an ECHO message, it
-- sends and ECHO reply to the source of the ECHO message.
nwIpxEchoAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
disabled(2), -- shutdown the router
enabled(3) -- startup the router
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the IPX Echo. Enabled (3) causes
IPX ECHO to become active on any configured IPX router ports.
Disabled (2) causes IPX Echo to perform a graceful shutdown on any
active IPX router port."
DEFVAL { disabled }
::= { nwIpxEchoConfig 1 }
nwIpxEchoOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
disabled(2), -- not running
enabled(3), -- running
pending-disable(4), -- shut-down in progress
pending-enable(5), -- start-up in progress
invalid-config(6) -- not running,invalid config
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the operating condition of IPX Echo."
::= { nwIpxEchoConfig 2 }
nwIpxEchoAdminReset OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
reset(2) -- force a reset
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets IPX Echo. Reset (2) will force a restart of IPX Echo without
a graceful shutdown on any active IPX router port, without effecting
any other router applications."
::= { nwIpxEchoConfig 3 }
nwIpxEchoOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the amount of time, in hundredths of a second, that IPX
Echo has been in its current administrative state,
nwIpxEchoOperStatus."
::= { nwIpxEchoConfig 4 }
nwIpxEchoVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current revision level of IPX Echo firmware."
::= { nwIpxEchoConfig 5 }
-- IPX Echo System (aggregate) Counters
-- This group contains the aggregate (device-wide) IPX Echo packet
-- and byte counters.
nwIpxEchoCtrAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the aggregae (device-wide) IPX Echo
packet and byte counters. Enabled (3) causes these counters to become
active on any router port running IPX Echo. Disabled (2) causes these
counters to become inactive on all router ports."
::= { nwIpxEchoCounters 1 }
nwIpxEchoCtrReset OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the aggregate (device-wide) IPX Echo packet and byte counters.
Reset (2) resets the IPX Echo aggregate counters to 0.
nwIpxEchoCtrOperationalTime is also reset to 0."
::= { nwIpxEchoCounters 2 }
nwIpxEchoCtrOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the amount of time, in hundredths of a second, that the
aggreagate (device-wide) IPX Echo packet and byte counters have been in
the current administrative state."
::= { nwIpxEchoCounters 3 }
nwIpxEchoCtrInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Echo packets that have been recieved,
device-wide, during nwIpxEchoCtrOperationalTime."
::= { nwIpxEchoCounters 4 }
nwIpxEchoCtrOutPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Echo packets that have been
transmitted, device-wide, during nwIpxEchoCtrOperationalTIme."
::= { nwIpxEchoCounters 5 }
nwIpxEchoCtrFilteredPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Echo packets that have been
administratively filtered, device-wide, during
nwIpxEchoCtrOperationalTime."
::= { nwIpxEchoCounters 6 }
nwIpxEchoCtrDiscardPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Echo packets that have been discarded,
device-wide, during nwIpxEchoCtrOperationalTime."
::= { nwIpxEchoCounters 7 }
nwIpxEchoCtrInBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Echo packets that have been recieved,
device-wide, during nwIpxEchoCtrOperationalTime."
::= { nwIpxEchoCounters 8 }
nwIpxEchoCtrOutBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Echo packets that have been
transmitted, device-wide, during nwIpxEchoCtrOperationalTime."
::= { nwIpxEchoCounters 9 }
nwIpxEchoCtrFilteredBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Echo packets that have been
administratively filtered, device-wide, during
nwIpxEchoCtrOperationalTime."
::= { nwIpxEchoCounters 10 }
nwIpxEchoSCtrDiscardBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the Echo packets that
have been discarded, during nwIpxEchoCtrOperationalTime."
::= { nwIpxEchoCounters 11 }
-- IPX Echo Interface Table
-- This table contains the managed objects used to setup and configure
-- Echo on a per router port basis.
nwIpxEchoIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxEchoIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains an entry for each router port configured for IPX
Echo. Each entry can contain different values, allowing the routing
protocol configuration to vary from router port to router port. This
table is indexed by nwIpxEchoIfIndex, which indicates the value of
MIB 2 ifindex, which identifies the router port for which the entry
exists."
::= { nwIpxEchoIfConfig 1 }
nwIpxEchoIfEntry OBJECT-TYPE
SYNTAX NwIpxEchoIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the IPX Echo information for the logical IPX interface for
which the entry exists."
INDEX { nwIpxEchoIfIndex }
::= { nwIpxEchoIfTable 1 }
NwIpxEchoIfEntry ::=
SEQUENCE {
nwIpxEchoIfIndex INTEGER,
nwIpxEchoIfAdminStatus INTEGER,
nwIpxEchoIfOperStatus INTEGER,
nwIpxEchoIfOperationalTime TimeTicks
}
nwIpxEchoIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This index corresponds to the primary index into the MIB 2 ifTable,
which describes the router port for which the entry exists."
::= { nwIpxEchoIfEntry 1 }
nwIpxEchoIfAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of IPX Echo on the router port for
which the entry exists. Enabled (2) causes this router port to
become active. Disabled (3) causes this router port to become
inactive."
DEFVAL { enabled }
::= { nwIpxEchoIfEntry 2 }
nwIpxEchoIfOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
disabled(2), -- not running
enabled(3), -- running
pending-disable(4), -- shut-down in progress
pending-enable(5), -- start-up in progress
invalid-config(6) -- not running,invalid config
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current operating condition of IPX Echo on the router
port for which the entry exists."
::= { nwIpxEchoIfEntry 3 }
nwIpxEchoIfOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the elapsed time, in hundredths of a second, that
nwIpxEchoIfAdminStatus has been in its current state."
::= { nwIpxEchoIfEntry 4 }
-- IPX Echo Interface Counters Table
-- This table contains the managed objects for IPX Echo packet and
-- byte counter on a per router port basis.
nwIpxEchoIfCtrTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxEchoIfCtrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the IPX Echo packet and byte counters for each
router port on this device."
::= { nwIpxEchoIfCounters 1 }
nwIpxEchoIfCtrEntry OBJECT-TYPE
SYNTAX NwIpxEchoIfCtrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This is the primary index into the Echo Interface Counter Table. This
number corresponds to the index into the MIB 2 Interface Table which
describes the router port for which the entry exists."
INDEX { nwIpxEchoIfCtrIfIndex }
::= { nwIpxEchoIfCtrTable 1 }
NwIpxEchoIfCtrEntry ::=
SEQUENCE {
nwIpxEchoIfCtrIfIndex INTEGER,
nwIpxEchoIfCtrAdminStatus INTEGER,
nwIpxEchoIfCtrReset INTEGER,
nwIpxEchoIfCtrOperationalTime TimeTicks,
nwIpxEchoIfCtrInPkts Counter,
nwIpxEchoIfCtrOutPkts Counter,
nwIpxEchoIfCtrFilteredPkts Counter,
nwIpxEchoIfCtrDiscardPkts Counter,
nwIpxEchoIfCtrInBytes Counter,
nwIpxEchoIfCtrOutBytes Counter,
nwIpxEchoIfCtrFilteredBytes Counter,
nwIpxEchoIfCtrDiscardBytes Counter
}
nwIpxEchoIfCtrIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the primary index into the IPX Echo Interface Counter Table.
This number corresponds to the index into the MIB 2 Interfcace Table
which describes the router port for which the entry exists."
::= { nwIpxEchoIfCtrEntry 1 }
nwIpxEchoIfCtrAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the IPX Echo packet and byte counters
on the IPX router port for which the entry exists. Enabled (3) causes
these counters to become active on the router port configured for IPX
Echo. Disabled (2) causes these counters to become inactive on the
configured IPX Echo router port."
::= { nwIpxEchoIfCtrEntry 2 }
nwIpxEchoIfCtrReset OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Resets the IPX Echo packet andbyte counters on the router port for which
the entryexists. Reset (2) resets the interface-specific counters to 0.
nwIpxEchoIfCtrOperationalTime is also reset to 0."
::= { nwIpxEchoIfCtrEntry 3 }
nwIpxEchoIfCtrOperationalTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the amount of time, in hundredths of a second, that the
interface-specific IPX Echo packet and byte counters have been in the
current administrative state on the router port for which the entry
exists."
::= { nwIpxEchoIfCtrEntry 4 }
nwIpxEchoIfCtrInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Echo packets that have been recieved,
on the router port for which the entry exists, during
nwIpxEchoIfCtrOperationalTime."
::= { nwIpxEchoIfCtrEntry 5 }
nwIpxEchoIfCtrOutPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Echo packets that have been
transmitted, on the router port for which the entry exists, during
nwIpxEchoIfCrOperationalTIme."
::= { nwIpxEchoIfCtrEntry 6 }
nwIpxEchoIfCtrFilteredPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Echo packets that have been
administratively filtered, on the router port for which the entry
exists, during nwIpxEchoIfCtrOperationalTime."
::= { nwIpxEchoIfCtrEntry 7 }
nwIpxEchoIfCtrDiscardPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of IPX Echo packets that have been discaded,
on the router port for which the entry exists, during
nwIpxEchoIfCtrOperationalTime."
::= { nwIpxEchoIfCtrEntry 8 }
nwIpxEchoIfCtrInBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX Echo packets that have
been recieved, on the router port for which the entry exists, during
nwIpxEchoIfCtrOpeationalTime."
::= { nwIpxEchoIfCtrEntry 9 }
nwIpxEchoIfCtrOutBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX Echo packets that have
been transmitted, on the router port for which the entry exists, during
nwIpxEchoIfCtrOperationalTime."
::= { nwIpxEchoIfCtrEntry 10 }
nwIpxEchoIfCtrFilteredBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX Echo packets that have
been administratively filtered and recieved on the router port for which
the entry exists, during nwIpxEchoIfCtrOperationalTime."
::= { nwIpxEchoIfCtrEntry 11 }
nwIpxEchoIfCtrDiscardBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of bytes in the IPX Echo packets that have
been discarded, that were recieved on the router port for which the
entry exists, during nwIpxEchoIfCtrOperationalTime."
::= { nwIpxEchoIfCtrEntry 12 }
--
-- IPX Hosts-to-Media Table
-- This table provides a mapping between IPX Network Protocol
-- addresses and their corresponding circuit identifiers (if
-- applicable), port numbers, and framing.
nwIpxHostMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxHostMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Ipx Address translation table used for mapping
an IPX address to a circuit identifier (if applicable),
corresponding port number, and framing type."
::= { nwIpxHostsToMedia 1 }
nwIpxHostMapEntry OBJECT-TYPE
SYNTAX NwIpxHostMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains one IpxAddress to circuit
equivalence. Also provided is the framing required to
converse with this host, and the corresponding logical
port number."
INDEX { nwIpxHostMapIfIndex, nwIpxHostMapIpxAddr }
::= { nwIpxHostMapTable 1 }
NwIpxHostMapEntry ::=
SEQUENCE {
nwIpxHostMapIfIndex INTEGER,
nwIpxHostMapIpxAddr IpxAddress,
nwIpxHostMapPhysAddr PhysAddress,
nwIpxHostMapType INTEGER,
nwIpxHostMapCircuitID INTEGER,
nwIpxHostMapFraming INTEGER,
nwIpxHostMapPortNumber INTEGER
}
nwIpxHostMapIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the primary (major) index into the Ipx HostMap
table. This number corresponds to the index into the MIB-2
Interfaces Group which describes the IPX router port for which
the entry exists."
::= { nwIpxHostMapEntry 1 }
nwIpxHostMapIpxAddr OBJECT-TYPE
SYNTAX IpxAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IpxAddress of the host on the corresponding interface
and circuit (if applicable). The IpxAddress consists of a network
number of 4 octets followed by 6 octets of node identifier."
::= { nwIpxHostMapEntry 2 }
nwIpxHostMapPhysAddr OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The media-dependent 'physical' address. The value of
this object is 0 for entries indicating native-wan(8)
framing."
::= { nwIpxHostMapEntry 3 }
nwIpxHostMapType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
invalid(2),
dynamic(3),
static(4),
inactive(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to the value invalid(2) has
the effect of invalidating the corresponding entry in the
nwIpxHostMapTable. That is, it effectively dissasociates the
circuit and/or interface identified with said entry from the
mapping identified with said entry. It is an implementation-
specific matter as to whether the agent removes an invalidated
entry from the table. Accordingly, management stations must be
prepared to receive tabular information from agents that
corresponds to entries not currently in use. Proper inter-
pretation of such entries requires examination of the relevant
wIpxHostMapType object."
::= { nwIpxHostMapEntry 4 }
nwIpxHostMapCircuitID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The identifier for the virtual circuit present on the
interface. On an interface configured for Frame Relay,
this number is the DLCI for the IPX Address at the end of
the circuit. For non-WAN interfaces, the value of this
object is zero."
::= { nwIpxHostMapEntry 5 }
nwIpxHostMapFraming OBJECT-TYPE
SYNTAX INTEGER { -- valid media types
other(1), -- experimental
ethernet(2), -- ethernet
snap(3), -- enet,fddi,and token ring
i8022(4), -- enet, token ring, and fddi
novell(6), -- ethernet and fddi
nativewan(8), -- wan media types
encapenet(9), -- wan media types
encapenet8022(10), -- wan media types
encapenetsnap(11), -- wan media types
encapenetnovell(12), -- wan media types
encaptr8022(13), -- wan media types
encaptrsnap(14), -- wan media types
encapfddi8022(15), -- wan media types
encapfddisnap(16), -- wan media types
canonical(17) -- special, tbd
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the framing type required to converse with the
host for which this entry exists."
::= { nwIpxHostMapEntry 6 }
nwIpxHostMapPortNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique value for the logical port number. It's value
ranges between 1 and a maximum value which is dependent on both
the number of configured interfaces in the system and the number
of circuits present on those interfaces which are of WAN type."
::= { nwIpxHostMapEntry 7 }
-- IPX Event Group
nwIpxEventAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of IPX event logging. Enabled (3)
causes the event log to become active. Disabled (2) causes the event log
to become inactive."
DEFVAL { disabled }
::= { nwIpxEventLogConfig 1 }
nwIpxEventMaxEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the maximum size of the event log table. When the table size
exceeds the maximum, the first entry is deleted until the size of
the table does not exceed the maximum."
DEFVAL { 100 }
::= { nwIpxEventLogConfig 2 }
nwIpxEventTraceAll OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Sets the administrative state of the event log. Enabled (3) allows
logging of all event types on all router ports from all protocols
and components. Disabled (2) causes the filter table to specify
which events to log."
DEFVAL { enabled }
::= { nwIpxEventLogConfig 3 }
-- Event Log Filter Table
-- The Event Log Filter Table contains the managed objects used to set-up
-- and configure log entries.
nwIpxEventFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxEventFilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains an entry for each event filter configured for
IPX Routing Services events."
::= { nwIpxEventLogFilterTable 1 }
nwIpxEventFilterEntry OBJECT-TYPE
SYNTAX NwIpxEventFilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry describes an event filter which defines a particular type
of event to be logged to the event log. The nwIpxEventProtocol
refers to the instance used in the nwRtgProtocolTable and
nwComponentTable specified by the Cabletron Routing Services MIB,
and identifies the protocol to which the entry applies."
INDEX { nwIpxEventFltrProtocol, nwIpxEventFltrIfNum }
::= { nwIpxEventFilterTable 1 }
NwIpxEventFilterEntry ::=
SEQUENCE {
nwIpxEventFltrProtocol INTEGER,
nwIpxEventFltrIfNum INTEGER,
nwIpxEventFltrControl INTEGER,
nwIpxEventFltrType INTEGER,
nwIpxEventFltrSeverity INTEGER,
nwIpxEventFltrAction INTEGER
}
nwIpxEventFltrProtocol OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specifies the routing protocol involved in the event for which the
event filter exists."
::= { nwIpxEventFilterEntry 1 }
nwIpxEventFltrIfNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specifies the router port involved in the event for which the event
filter exists."
::= { nwIpxEventFilterEntry 2 }
nwIpxEventFltrControl OBJECT-TYPE
SYNTAX INTEGER {
other(1),
delete(2),
add(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this value to 3 to add the event filter to the Event Filter
Table. Set this value to 2 to delete the event filter from the Event
Filter Table."
DEFVAL { add }
::= { nwIpxEventFilterEntry 3 }
nwIpxEventFltrType OBJECT-TYPE
SYNTAX INTEGER {
misc(1),
timer(2),
rcv(4),
xmit(8),
event(16),
error(32)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This 6 bit mask specifies the types of events to be logged. By
default all 6 bits are set to 1, indicating that all types of events
will be logged. Setting any bit to 0 removes an event type from this
field and prevents that type of event from being logged. Adding
event types to this field will enable those types of events to be
logged."
DEFVAL { misc }
::= { nwIpxEventFilterEntry 4 }
nwIpxEventFltrSeverity OBJECT-TYPE
SYNTAX INTEGER {
highest(1),
highmed(2),
highlow(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object controls the amount of logging by ignoring events of
lower priority than specified by this filter value. The highest
value will ignore all events except those of the highest severity.
`Highmed' will log all events highest priority through lowest.
`Highlow' will log all events highest priority through lowest. The
`highmed' severity is the default setting."
DEFVAL { highest }
::= { nwIpxEventFilterEntry 5 }
nwIpxEventFltrAction OBJECT-TYPE
SYNTAX INTEGER {
log(1),
trap(2),
log-trap(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This field specifies how the events are to be logged. Logging to the
`log' stores the events in the event log table. Logging to `trap' sends
events out through the trap mechanism."
DEFVAL { log }
::= { nwIpxEventFilterEntry 6 }
-- Event Log Table
-- The Event Log Table contains the logged events.
nwIpxEventTable OBJECT-TYPE
SYNTAX SEQUENCE OF NwIpxEventEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains an entry for each event that has been logged."
::= { nwIpxEventLogTable 1 }
nwIpxEventEntry OBJECT-TYPE
SYNTAX NwIpxEventEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the information about an event that has been
logged to the event table."
INDEX { nwIpxEventNumber }
::= { nwIpxEventTable 1 }
NwIpxEventEntry ::=
SEQUENCE {
nwIpxEventNumber INTEGER,
nwIpxEventTime TimeTicks,
nwIpxEventType INTEGER,
nwIpxEventSeverity INTEGER,
nwIpxEventProtocol INTEGER,
nwIpxEventIfNum INTEGER,
nwIpxEventTextString OCTET STRING
}
nwIpxEventNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An ordinal value assigned to the event for which the entry exists.
nwIpxEventNumber is assigned so that each event in the event log can
be uniquely identified by the value of nwIpxEventNumber."
::= { nwIpxEventEntry 1 }
nwIpxEventTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the time at which the event was logged to the event log."
::= { nwIpxEventEntry 2 }
nwIpxEventType OBJECT-TYPE
SYNTAX INTEGER {
misc(1),
timer(2),
rcv(4),
xmit(8),
event(16),
error(32)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the type of event that was logged."
::= { nwIpxEventEntry 3 }
nwIpxEventSeverity OBJECT-TYPE
SYNTAX INTEGER {
highest(1),
highmed(2),
highlow(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the priority that was assigned to this type event."
::= { nwIpxEventEntry 4 }
nwIpxEventProtocol OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the routing protocol that was involved in this event."
::= { nwIpxEventEntry 5 }
nwIpxEventIfNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the router port that was involved in the event."
::= { nwIpxEventEntry 6 }
nwIpxEventTextString OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the actual text string that was logged."
::= { nwIpxEventEntry 7 }
END