mibs/MIBS/ibm/IBM-Director-Alert-MIB

3009 lines
108 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
IBM-Director-Alert-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Integer32 FROM SNMPv2-SMI
DisplayString, TruthValue FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF
SnmpAdminString FROM SNMP-FRAMEWORK-MIB;
ibm OBJECT IDENTIFIER ::= { enterprises 2 }
ibmProd OBJECT IDENTIFIER ::= { ibm 6 }
director OBJECT IDENTIFIER ::= { ibmProd 159 }
description OBJECT IDENTIFIER ::= { director 202 }
details OBJECT IDENTIFIER ::= { director 9696 }
directorTraps MODULE-IDENTITY
LAST-UPDATED "200404210000Z"
ORGANIZATION "IBM Corp."
CONTACT-INFO
"IBM Corporation"
DESCRIPTION
"This MIB is for use with the Event Action Plan Builder of
IBM Director."
REVISION "200404210000Z"
DESCRIPTION
"This MIB was revised to include traps for more possible
events generated by the IBM Director event subsystem."
REVISION "200307090000Z"
DESCRIPTION
"The initial version of this MIB."
::= { director 201 }
--
-- Generic trap for events
--
generalEvent NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
STATUS current
DESCRIPTION
"This is a IBM Director event converted into an SNMP trap.
This trap is only used for events with no mapping."
::= { directorTraps 2 }
--
-- Topology traps
--
directorFamily OBJECT IDENTIFIER ::= { directorTraps 1 }
topology OBJECT IDENTIFIER ::= { directorFamily 1 }
online NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
STATUS current
DESCRIPTION
"The managed object's state has changed to online."
::= { topology 1 }
offline NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
STATUS current
DESCRIPTION
"The managed object's state has changed to offline."
::= { topology 2 }
create NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
STATUS current
DESCRIPTION
"The managed object has been created."
::= { topology 3 }
change NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
STATUS current
DESCRIPTION
"The managed object has changed."
::= { topology 4 }
destroy NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
STATUS current
DESCRIPTION
"The managed object has been destroyed."
::= { topology 5 }
--
-- Director Agent traps
--
directorAgent OBJECT IDENTIFIER ::= { directorFamily 2 }
processMonitor NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
actualValue, duration, monitorResource, thresholdName, thresholdValue }
STATUS current
DESCRIPTION
"The process monitor threshold has generated
an event."
::= { directorAgent 1 }
cpuMonitors OBJECT IDENTIFIER ::= { directorAgent 2 }
cpuUtilization NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
actualValue, duration, monitorResource, thresholdName, thresholdValue }
STATUS current
DESCRIPTION
"The CPU utilization monitor threshold has generated
an event."
::= { cpuMonitors 1 }
processCount NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
actualValue, duration, monitorResource, thresholdName, thresholdValue }
STATUS current
DESCRIPTION
"The process count monitor threshold has generated
an event."
::= { cpuMonitors 2 }
diskMonitors OBJECT IDENTIFIER ::= { directorAgent 3 }
driveSpaceUsed NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
actualValue, duration, monitorResource, thresholdName, thresholdValue }
STATUS current
DESCRIPTION
"The drive space used monitor threshold has generated
an event."
::= { diskMonitors 1 }
driveSpaceUsedPercent NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
actualValue, duration, monitorResource, thresholdName, thresholdValue }
STATUS current
DESCRIPTION
"The percentage of drive space used monitor threshold has generated
an event."
::= { diskMonitors 2 }
driveSpaceRemaining NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
actualValue, duration, monitorResource, thresholdName, thresholdValue }
STATUS current
DESCRIPTION
"The drive space remaining monitor threshold has generated
an event."
::= { diskMonitors 3 }
driveWorkload NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
actualValue, duration, monitorResource, thresholdName, thresholdValue }
STATUS current
DESCRIPTION
"The drive workload monitor threshold has generated
an event."
::= { diskMonitors 4 }
memoryMonitors OBJECT IDENTIFIER ::= { directorAgent 4 }
lockedMemory NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
actualValue, duration, monitorResource, thresholdName, thresholdValue }
STATUS current
DESCRIPTION
"The locked memory monitor threshold has generated
an event."
::= { memoryMonitors 1 }
memoryUsage NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
actualValue, duration, monitorResource, thresholdName, thresholdValue }
STATUS current
DESCRIPTION
"The memory usage monitor threshold has generated
an event."
::= { memoryMonitors 2 }
nicMonitors OBJECT IDENTIFIER ::= { directorAgent 5 }
-- Add nic monitors here
ntPerfMonitors OBJECT IDENTIFIER ::= { directorAgent 6 }
totalPrivilegedTimePercent NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
actualValue, duration, monitorResource, thresholdName, thresholdValue }
STATUS current
DESCRIPTION
"The percentage of total privileged time monitor
threshold has generated an event."
::= { ntPerfMonitors 1 }
fileReadOperationsPerSec NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
actualValue, duration, monitorResource, thresholdName, thresholdValue }
STATUS current
DESCRIPTION
"The files read per second monitor threshold has
generated an event."
::= { ntPerfMonitors 2 }
-- thread NOTIFICATION-TYPE
-- OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
-- STATUS current
-- DESCRIPTION
-- ""
--::= { ntPerfMonitor 3 }
tcpipMonitors OBJECT IDENTIFIER ::= { directorAgent 7 }
udpPacketsSentPerSec NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
actualValue, duration, monitorResource, thresholdName, thresholdValue }
STATUS current
DESCRIPTION
"A threshold event for the number of UDP packets
sent per second."
::= { tcpipMonitors 1 }
udpPacketsReceivedPerSec NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
actualValue, duration, monitorResource, thresholdName, thresholdValue }
STATUS current
DESCRIPTION
"A threshold event for the number of UDP packets
received per second."
::= { tcpipMonitors 2 }
ipPacketsSentPerSec NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
actualValue, duration, monitorResource, thresholdName, thresholdValue }
STATUS current
DESCRIPTION
"A threshold event for the number of IP packets
sent per second."
::= { tcpipMonitors 3 }
ipPacketsReceivedPerSec NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
actualValue, duration, monitorResource, thresholdName, thresholdValue }
STATUS current
DESCRIPTION
"A threshold event for the number of IP packets
received per second."
::= { tcpipMonitors 4 }
ipErrorPacketsReceivedPerSec NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
actualValue, duration, monitorResource, thresholdName, thresholdValue }
STATUS current
DESCRIPTION
"A threshold event for the number of IP packets
received with errors per second."
::= { tcpipMonitors 5 }
tcpConnections NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
actualValue, duration, monitorResource, thresholdName, thresholdValue }
STATUS current
DESCRIPTION
"A threshold event for the number of TCP connections."
::= { tcpipMonitors 6 }
monitorEventDetails OBJECT IDENTIFIER ::= { directorAgent 8 }
actualValue OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual value of the monitor."
::= { monitorEventDetails 1 }
duration OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The duration of this monitor."
::= { monitorEventDetails 2 }
monitorResource OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The monitor resource."
::= { monitorEventDetails 3 }
thresholdName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the monitor threshold."
::= { monitorEventDetails 4 }
thresholdValue OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the monitor threshold."
::= { monitorEventDetails 5 }
--
-- Test trap
--
test OBJECT IDENTIFIER ::= { directorFamily 3 }
action NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
STATUS current
DESCRIPTION
"The test action event. An internally generated event
for the purpose of testing the action configuration."
::= { test 1 }
--
-- Console traps
--
console OBJECT IDENTIFIER ::= { directorFamily 4 }
consoleEventDetails OBJECT IDENTIFIER ::= { console 1 }
userID OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The console user ID."
::= { consoleEventDetails 1 }
address OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The console address."
::= { consoleEventDetails 2 }
userName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The console username."
::= { consoleEventDetails 3 }
userDescription OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The console username's description."
::= { consoleEventDetails 4 }
userLocale OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The console user's locale."
::= { consoleEventDetails 5 }
logonFailure OBJECT IDENTIFIER ::= { console 2 }
badPassword NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
userID, address }
STATUS current
DESCRIPTION
"When attempting to logon to the console,
a bad password was used."
::= { logonFailure 1 }
badUserID NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
userID, address }
STATUS current
DESCRIPTION
"When attempting to logon to the console,
a bad user ID was used."
::= { logonFailure 2 }
disabledUserID NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
userID, address }
STATUS current
DESCRIPTION
"When attempting to logon to the console,
a disabled user ID was used."
::= { logonFailure 3 }
downlevelConsole NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
userID, address }
STATUS current
DESCRIPTION
"When attempting to logon to the console,
a downlevel console was used."
::= { logonFailure 4 }
expiredPassword NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
userID, address }
STATUS current
DESCRIPTION
"When attempting to logon to the console,
an expired password was used."
::= { logonFailure 5 }
tooManyActiveIDs NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
userID, address }
STATUS current
DESCRIPTION
"When attempting to logon to the console,
too many IDs were active."
::= { logonFailure 6 }
tooManyActiveLogons NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
userID, address }
STATUS current
DESCRIPTION
"When attempting to logon to the console,
too many logons were active."
::= { logonFailure 7 }
uplevelConsole NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
userID, address }
STATUS current
DESCRIPTION
"When attempting to logon to the console,
an uplevel console was used."
::= { logonFailure 8 }
logoff NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
userID, address, userName, userDescription, userLocale }
STATUS current
DESCRIPTION
"A user has logged off the console."
::= { console 3 }
logon NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
userID, address, userName, userDescription, userLocale }
STATUS current
DESCRIPTION
"A user has logged on the console."
::= { console 4 }
--
-- CIM traps
--
cimFamily OBJECT IDENTIFIER ::= { directorTraps 3 }
windowsNTEventLog OBJECT IDENTIFIER ::= { cimFamily 1 }
windowsNTEventLogEventDetails OBJECT IDENTIFIER ::= { windowsNTEventLog 1 }
category OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Windows Event Log category."
::= { windowsNTEventLogEventDetails 1 }
categoryString OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Windows Event Log category string."
::= { windowsNTEventLogEventDetails 2 }
computerName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The computer name of the Windows Event Log event."
::= { windowsNTEventLogEventDetails 3 }
data OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Windows Event Log data for the event."
::= { windowsNTEventLogEventDetails 4 }
eventLogCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Windows Event Log numeric event ID."
::= { windowsNTEventLogEventDetails 5 }
eventLogIdentifier OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Windows Event Log numeric event identifier."
::= { windowsNTEventLogEventDetails 6 }
eventLogType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Windows Event Log numeric event type."
::= { windowsNTEventLogEventDetails 7 }
insertionStrings OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Windows Event Log insertion strings."
::= { windowsNTEventLogEventDetails 8 }
logFile OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Windows Event Log file name."
::= { windowsNTEventLogEventDetails 9 }
message OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Windows Event Log message string."
::= { windowsNTEventLogEventDetails 10 }
recordNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Windows Event Log record number."
::= { windowsNTEventLogEventDetails 11 }
sourceName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Windows Event Log source name."
::= { windowsNTEventLogEventDetails 12 }
type OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Windows Event Log type."
::= { windowsNTEventLogEventDetails 13 }
user OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Windows Event Log user."
::= { windowsNTEventLogEventDetails 14 }
applicationLog NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
category, categoryString, computerName, data, eventLogCode, eventLogIdentifier, eventLogType,
insertionStrings, logFile, message, recordNumber, sourceName, type, user }
STATUS current
DESCRIPTION
"The Windows NT application event log has changed."
::= { windowsNTEventLog 2 }
securityLog NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
category, categoryString, computerName, data, eventLogCode, eventLogIdentifier, eventLogType,
insertionStrings, logFile, message, recordNumber, sourceName, type, user }
STATUS current
DESCRIPTION
"The Windows NT application security log has changed."
::= { windowsNTEventLog 3 }
systemLog NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
STATUS current
DESCRIPTION
"The Windows NT application system log has changed."
::= { windowsNTEventLog 4 }
windowsNTService OBJECT IDENTIFIER ::= { cimFamily 2 }
windowsNTServiceEventDetails OBJECT IDENTIFIER ::= { windowsNTService 1 }
acceptPause OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether this service accepts the pause state change."
::= { windowsNTServiceEventDetails 1 }
acceptStop OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether this service accepts the stop state change."
::= { windowsNTServiceEventDetails 2 }
caption OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The caption string for this service."
::= { windowsNTServiceEventDetails 3 }
checkPoint OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The service's check point."
::= { windowsNTServiceEventDetails 4 }
creationClassName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The creation class name for the service."
::= { windowsNTServiceEventDetails 5 }
serviceDescription OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of the service."
::= { windowsNTServiceEventDetails 6 }
desktopInteract OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether the service interacts with the desktop."
::= { windowsNTServiceEventDetails 7 }
displayName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The displayable name for the service."
::= { windowsNTServiceEventDetails 8 }
errorControl OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The error control value for the service."
::= { windowsNTServiceEventDetails 9 }
exitCode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The exit code of the process for the service."
::= { windowsNTServiceEventDetails 10 }
name OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the service."
::= { windowsNTServiceEventDetails 11 }
pathName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The path name for the service."
::= { windowsNTServiceEventDetails 12 }
processId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The process ID of the running service."
::= { windowsNTServiceEventDetails 13 }
serviceSpecificExitCode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The specific exit code for the service."
::= { windowsNTServiceEventDetails 14 }
serviceType OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of service."
::= { windowsNTServiceEventDetails 15 }
startMode OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The start mode for the service."
::= { windowsNTServiceEventDetails 16 }
startName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The start name for the service."
::= { windowsNTServiceEventDetails 17 }
started OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether this service has started."
::= { windowsNTServiceEventDetails 18 }
serviceState OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of the service."
::= { windowsNTServiceEventDetails 19 }
status OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the service."
::= { windowsNTServiceEventDetails 20 }
systemCreationClassName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system creation class name for the service."
::= { windowsNTServiceEventDetails 21 }
systemName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system name for the service."
::= { windowsNTServiceEventDetails 22 }
tagId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The tag ID of the service."
::= { windowsNTServiceEventDetails 23 }
waitHint OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the wait hint for the service."
::= { windowsNTServiceEventDetails 24 }
startedService NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
acceptPause, acceptStop, caption, checkPoint, creationClassName, serviceDescription,
desktopInteract, displayName, errorControl, exitCode, name, pathName, processId,
serviceSpecificExitCode, serviceType, startMode, startName, started, serviceState,
status, systemCreationClassName, systemName, tagId, waitHint }
STATUS current
DESCRIPTION
"A Windows NT service has started."
::= { windowsNTService 2 }
stoppedService NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
acceptPause, acceptStop, caption, checkPoint, creationClassName, serviceDescription,
desktopInteract, displayName, errorControl, exitCode, name, pathName, processId,
serviceSpecificExitCode, serviceType, startMode, startName, started, serviceState,
status, systemCreationClassName, systemName, tagId, waitHint }
STATUS current
DESCRIPTION
"A Windows NT service has stopped."
::= { windowsNTService 3 }
windowsRegistry OBJECT IDENTIFIER ::= { cimFamily 3 }
windowsRegistryEventDetails OBJECT IDENTIFIER ::= { windowsRegistry 1 }
hive OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Windows Registry hive for this event."
::= { windowsRegistryEventDetails 1 }
rootPath OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Windows Registry root path for this event."
::= { windowsRegistryEventDetails 2 }
securityDescriptor OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Windows Registry security descriptor for this event."
::= { windowsRegistryEventDetails 3 }
timeCreated OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time this item was created in the Windows Registry."
::= { windowsRegistryEventDetails 4 }
softwareTreeChanged NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
hive, rootPath, securityDescriptor, timeCreated }
STATUS current
DESCRIPTION
"The Windows software tree section of the registry
has changed."
::= { windowsRegistry 2 }
systemTreeChanged NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
hive, rootPath, securityDescriptor, timeCreated }
STATUS current
DESCRIPTION
"The Windows system tree section of the registry
has changed."
::= { windowsRegistry 3 }
--
-- MPA traps
--
mpaFamily OBJECT IDENTIFIER ::= { directorTraps 4 }
mpaEventDetails OBJECT IDENTIFIER ::= { mpaFamily 1 }
alertCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alert code."
::= { mpaEventDetails 1 }
busId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The bus ID."
::= { mpaEventDetails 2 }
componentId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The component ID."
::= { mpaEventDetails 3 }
firmwareCode OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The firmware identification code."
::= { mpaEventDetails 4 }
ipAddress1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The first IP address."
::= { mpaEventDetails 5 }
ipAddress2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The second IP address."
::= { mpaEventDetails 6 }
issue OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The issue for the event."
::= { mpaEventDetails 7 }
powerDomain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The domain of the power supply."
::= { mpaEventDetails 8 }
reason OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The reason for the event."
::= { mpaEventDetails 9 }
scsiId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ID of the SCSI device."
::= { mpaEventDetails 10 }
side OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The side in which the event occured."
::= { mpaEventDetails 11 }
newState OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The new state."
::= { mpaEventDetails 12 }
temperatureSensor OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current temperature."
::= { mpaEventDetails 13 }
threshold OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The threshold for the event."
::= { mpaEventDetails 14 }
universalUniqueId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The universal unique ID."
::= { mpaEventDetails 15 }
senderUniversalUniqueId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The universal unique ID of the sender."
::= { mpaEventDetails 16 }
sourceUniversalUniqueId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The universal unique ID of the source."
::= { mpaEventDetails 17 }
unitNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit number."
::= { mpaEventDetails 18 }
voltageSensor OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage sensor."
::= { mpaEventDetails 19 }
component OBJECT IDENTIFIER ::= { mpaFamily 2 }
bladeServer OBJECT IDENTIFIER ::= { component 1 }
coD OBJECT IDENTIFIER ::= { bladeServer 1 }
codEnabled NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The CoD has been enabled."
::= { coD 1 }
bladeServerCommunication NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"Communication with a blade has been established."
::= { bladeServer 2 }
bladeServerInserted NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"A blade has been inserted."
::= { bladeServer 3 }
bladeServerRemoved NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"A blade has been removed."
::= { bladeServer 4 }
bus OBJECT IDENTIFIER ::= { component 2 }
busCommunication NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
busId, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"Communication with a bus has been established."
::= { bus 1 }
chassis OBJECT IDENTIFIER ::= { component 3 }
chassisConfiguration NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
componentId, firmwareCode, issue, powerDomain, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"The blade chassis configuration has changed."
::= { chassis 1 }
chassisFailed NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, issue, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The blade chassis has failed."
::= { chassis 2 }
dasd OBJECT IDENTIFIER ::= { component 4 }
dasdFailed NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, scsiId, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"a direct access storage device has failed."
::= { dasd 1 }
dasdInserted NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, scsiId, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"A direct access storage device has been inserted."
::= { dasd 2 }
dasdRemoved NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, scsiId, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"A direct access storage device has been removed."
::= { dasd 3 }
memory OBJECT IDENTIFIER ::= { component 5 }
memoryFailed NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"Some memory has failed."
::= { memory 1 }
componentFan OBJECT IDENTIFIER ::= { component 6 }
componentFanFailed NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"A fan has failed."
::= { componentFan 1 }
componentFanInserted NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"A fan has been inserted."
::= { componentFan 2 }
componentFanPfa NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"The fan component has generated a PFA."
::= { componentFan 3 }
componentFanRemoved NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"A fan has been removed."
::= { componentFan 4 }
hardwareInformation OBJECT IDENTIFIER ::= { component 7 }
hardwareCrashDump OBJECT IDENTIFIER ::= { hardwareInformation 1 }
hardwareCrashDumpAborted NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"A hardware crash dump was aborted."
::= { hardwareCrashDump 1 }
hardwareCrashDumpCompleted NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"A hardware crash dump has completed."
::= { hardwareCrashDump 2 }
hardwareCrashDumpInitiated NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"A hardware crash dump has been initiated."
::= { hardwareCrashDump 3 }
ioModule OBJECT IDENTIFIER ::= { component 8 }
ioModuleConfiguration NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, ipAddress1, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"An I/O module's configuration has changed."
::= { ioModule 1 }
ioModuleFailed NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"An I/O module has failed."
::= { ioModule 2 }
ioModuleInserted NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"An I/O module has been inserted."
::= { ioModule 3 }
ioModulePost NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"An I/O module has past POST."
::= { ioModule 4 }
ioModulePower OBJECT IDENTIFIER ::= { ioModule 5 }
ioModulePowerOn NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"An I/O module has been powered on."
::= { ioModulePower 1 }
ioModulePowerOff NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"An I/O module has been powered off."
::= { ioModulePower 2 }
ioModuleRedundancy NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"An I/O module is a redundancy."
::= { ioModule 6 }
ioModuleRemoved NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"An I/O module has been removed."
::= { ioModule 7 }
kvm OBJECT IDENTIFIER ::= { component 9 }
kvmOwner NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The KVM owner has changed."
::= { kvm 1 }
osImage OBJECT IDENTIFIER ::= { component 10 }
osImageCrashDump OBJECT IDENTIFIER ::= { osImage 1 }
osImageCrashDumpAborted NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The operating system image crash dump was aborted."
::= { osImageCrashDump 1 }
osImageCrashDumpCompleted NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The operating system image crash dump has completed."
::= { osImageCrashDump 2 }
osImageCrashDumpInitiated NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The operating system image crash dump has been initiated."
::= { osImageCrashDump 3 }
componentPfa NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"A component has generated a PFA."
::= { component 11 }
powerSubsystem OBJECT IDENTIFIER ::= { component 12 }
powerSubsystemLowFuel NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The power subsystem indicates low fuel."
::= { powerSubsystem 1 }
powerSubsystemOverCurrent NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The power subsystem indicates over current."
::= { powerSubsystem 2 }
powerSubsystemOverPower NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The power subsystem indicates over power."
::= { powerSubsystem 3 }
powerSubsystemRedundancy NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The power subsystem indicates a redundancy."
::= { powerSubsystem 4 }
powerSupply OBJECT IDENTIFIER ::= { component 13 }
powerSupplyFailed NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, reason, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"A power supply has failed."
::= { powerSupply 1 }
powerSupplyInserted NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"A power supply has been inserted."
::= { powerSupply 2 }
powerSupplyRemoved NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"A power supply has been removed."
::= { powerSupply 3 }
server OBJECT IDENTIFIER ::= { component 14 }
serverPower OBJECT IDENTIFIER ::= { server 1 }
serverPowerOff NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The server has powered off."
::= { serverPower 1 }
serverPowerOn NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The server has powered on."
::= { serverPower 2 }
serverPowerState NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, newState, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The server's power state has changed."
::= { server 2 }
serviceProcessor OBJECT IDENTIFIER ::= { component 15 }
serviceProcessorActive NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"A service processor is now active."
::= { serviceProcessor 1 }
serviceProcessorConfiguration NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"A service processor configuration has changed."
::= { serviceProcessor 2 }
serviceProcessorInserted NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"A service processor has been inserted."
::= { serviceProcessor 3 }
serviceProcessorLog NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"A service processor has generated a log."
::= { serviceProcessor 4 }
serviceProcessorNetworkStack NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, ipAddress1, ipAddress2, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"A service processor network stack has changed."
::= { serviceProcessor 5 }
serviceProcessorRedundancy NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"A service processor detected a redundancy."
::= { serviceProcessor 6 }
serviceProcessorRemoteLogin NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"A remove login was made into the service processor."
::= { serviceProcessor 7 }
serviceProcessorRemoved NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"A service processor has been removed."
::= { serviceProcessor 8 }
serviceProcessorRestart NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"A service processor has been restarted."
::= { serviceProcessor 9 }
serviceProcessorTest NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"A service processor test was issued."
::= { serviceProcessor 10 }
smpExpansionModule OBJECT IDENTIFIER ::= { component 16 }
smpExpansionModuleDisabled NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"An SMP expansion module has been disabled."
::= { smpExpansionModule 1 }
usb OBJECT IDENTIFIER ::= { component 17 }
usbInserted NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"A USB device has been inserted."
::= { usb 1 }
usbOwner NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"A USB device owner has changed."
::= { usb 2 }
usbRemoved NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"A USB device has been removed."
::= { usb 3 }
vrm OBJECT IDENTIFIER ::= { component 18 }
vrmFailed NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
STATUS current
DESCRIPTION
"The VRM has failed."
::= { vrm 1 }
critical OBJECT IDENTIFIER ::= { mpaFamily 3 }
hardDiskDrive NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
universalUniqueId }
STATUS current
DESCRIPTION
"A hard disk drive is in critical state."
::= { critical 1 }
multipleFanFailure NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
universalUniqueId }
STATUS current
DESCRIPTION
"Multiple fans have failed."
::= { critical 2 }
powerFailure OBJECT IDENTIFIER ::= { critical 3 }
powerFailureEpow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
unitNumber, universalUniqueId }
STATUS current
DESCRIPTION
"There was a critical power failure as a result of an EPOW."
::= { powerFailure 1 }
powerFailureFailed NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
unitNumber, universalUniqueId }
STATUS current
DESCRIPTION
"There was a critical power failure as a result of something failing."
::= { powerFailure 2 }
powerFailureRemoved NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
unitNumber, universalUniqueId }
STATUS current
DESCRIPTION
"There was a critical power failure as a result of something removed."
::= { powerFailure 3 }
criticalTamper NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
universalUniqueId }
STATUS current
DESCRIPTION
"Tampering with the system has caused a critical state."
::= { critical 4 }
criticalTemperature OBJECT IDENTIFIER ::= { critical 5 }
criticalTemperatureAmbient NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"The ambient temperature is in a critical state."
::= { criticalTemperature 1 }
criticalTemperaturePci NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"The PCI temperature is in a critical state."
::= { criticalTemperature 2 }
criticalTemperaturePlanar NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"The planar temperature is in a critical state."
::= { criticalTemperature 3 }
criticalVoltage OBJECT IDENTIFIER ::= { critical 6 }
criticalTwelveVolts OBJECT IDENTIFIER ::= { criticalVoltage 1 }
criticalTwelveVoltsHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 12V high has been detected."
::= { criticalTwelveVolts 1 }
criticalTwelveVoltsLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 12V low has been detected."
::= { criticalTwelveVolts 2 }
criticalTwelveVoltsFaultA NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 12V fault A has been detected."
::= { criticalVoltage 2 }
criticalTwelveVoltsFaultB NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 12V fault B has been detected."
::= { criticalVoltage 3 }
criticalTwelveVoltsFaultC NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 12V fault C has been detected."
::= { criticalVoltage 4 }
criticalTwelveVoltsFaultD NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 12V fault D has been detected."
::= { criticalVoltage 5 }
criticalOneVolt OBJECT IDENTIFIER ::= { criticalVoltage 6 }
criticalOneVoltHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 1V high has been detected."
::= { criticalOneVolt 1 }
criticalOneVoltLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 1V low has been detected."
::= { criticalOneVolt 2 }
criticalTwoVolts OBJECT IDENTIFIER ::= { criticalVoltage 7 }
criticalTwoVoltsHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 2V high has been detected."
::= { criticalTwoVolts 1 }
criticalTwoVoltsLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 2V low has been detected."
::= { criticalTwoVolts 2 }
criticalThreeVolts OBJECT IDENTIFIER ::= { criticalVoltage 8 }
criticalThreeVoltsHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 3V high has been detected."
::= { criticalThreeVolts 1 }
criticalThreeVoltsLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 3V low has been detected."
::= { criticalThreeVolts 2 }
criticalThreeVoltsPci OBJECT IDENTIFIER ::= { criticalVoltage 9 }
criticalThreeVoltsPciHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 3V high has been detected for the PCI."
::= { criticalThreeVoltsPci 1 }
criticalThreeVoltsPciLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 3V low has been detected for the PCI."
::= { criticalThreeVoltsPci 2 }
criticalThreeVoltsStandby OBJECT IDENTIFIER ::= { criticalVoltage 10 }
criticalThreeVoltsStandbyHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 3V standby high has been detected."
::= { criticalThreeVoltsStandby 1 }
criticalThreeVoltsStandbyLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 3V standby low has been detected."
::= { criticalThreeVoltsStandby 2 }
criticalFiveVolts OBJECT IDENTIFIER ::= { criticalVoltage 11 }
criticalFiveVoltsHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 5V high has been detected."
::= { criticalFiveVolts 1 }
criticalFiveVoltsLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 5V low has been detected."
::= { criticalFiveVolts 2 }
criticalFiveVoltsFault OBJECT IDENTIFIER ::= { criticalVoltage 12 }
criticalFiveVoltsFaultHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 5V fault high has been detected."
::= { criticalFiveVoltsFault 1 }
criticalFiveVoltsFaultLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 5V fault low has been detected."
::= { criticalFiveVoltsFault 2 }
criticalFiveVoltsPci OBJECT IDENTIFIER ::= { criticalVoltage 13 }
criticalFiveVoltsPciHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 5V high has been detected for the PCI."
::= { criticalFiveVoltsPci 1 }
criticalFiveVoltsPciLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 5V low has been detected for the PCI."
::= { criticalFiveVoltsPci 2 }
criticalFiveVoltsStandby OBJECT IDENTIFIER ::= { criticalVoltage 14 }
criticalFiveVoltsStandbyHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 5V standby high has been detected."
::= { criticalFiveVoltsStandby 1 }
criticalFiveVoltsStandbyLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of 5V standby low has been detected."
::= { criticalFiveVoltsStandby 2 }
criticalNTwelveVolts OBJECT IDENTIFIER ::= { criticalVoltage 15 }
criticalNTwelveVoltsHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of negative 12V high has been detected."
::= { criticalNTwelveVolts 1 }
criticalNTwelveVoltsLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A critical state of negative 12V low has been detected."
::= { criticalNTwelveVolts 2 }
voltageRegulatorModuleFailure NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
universalUniqueId }
STATUS current
DESCRIPTION
"The voltage regulator module has failed."
::= { critical 7 }
deployment OBJECT IDENTIFIER ::= { mpaFamily 4 }
deploymentBoot NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"Deployment has generated a boot event."
::= { deployment 1 }
deploymentLoader NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"Deployment has generated a loader event."
::= { deployment 2 }
deploymentOs NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"Deployment has generated an operating system event."
::= { deployment 3 }
deploymentPost NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"Deployment has generated a POST event."
::= { deployment 4 }
environmental OBJECT IDENTIFIER ::= { mpaFamily 5 }
environmentalTemperature NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, side, sourceUniversalUniqueId, temperatureSensor,
unitNumber }
STATUS current
DESCRIPTION
"The environmental temperature has changed."
::= { environmental 1 }
environmentalVoltage NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
componentId, firmwareCode, senderUniversalUniqueId, side, sourceUniversalUniqueId, threshold,
voltageSensor }
STATUS current
DESCRIPTION
"The environmental voltage has changed."
::= { environmental 2 }
nonCritical OBJECT IDENTIFIER ::= { mpaFamily 6 }
nonCriticalFan OBJECT IDENTIFIER ::= { nonCritical 1 }
nonCriticalFanRemoved NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
universalUniqueId }
STATUS current
DESCRIPTION
"A fan has been removed."
::= { nonCriticalFan 1 }
redundantPower NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
universalUniqueId }
STATUS current
DESCRIPTION
"The system is now running on redundant power."
::= { nonCritical 2 }
singleFanFailure NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
unitNumber, universalUniqueId }
STATUS current
DESCRIPTION
"A single fan has failed."
::= { nonCritical 3 }
nonCriticalTemperature OBJECT IDENTIFIER ::= { nonCritical 4 }
nonCriticalTemperatureAmbient NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"The ambient temperature is in a non critical state."
::= { nonCriticalTemperature 1 }
nonCriticalTemperaturePci NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"The PCI temperature is in a non critical state."
::= { nonCriticalTemperature 2 }
nonCriticalTemperaturePlanar NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"The planar temperature is in a non critical state."
::= { nonCriticalTemperature 3 }
nonCriticalVoltage OBJECT IDENTIFIER ::= { nonCritical 5 }
nonCriticalTwelveVolts OBJECT IDENTIFIER ::= { nonCriticalVoltage 1 }
nonCriticalTwelveVoltsHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of 12V high has been detected."
::= { nonCriticalTwelveVolts 1 }
nonCriticalTwelveVoltsLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of 12V low has been detected."
::= { nonCriticalTwelveVolts 2 }
nonCriticalOneVolt OBJECT IDENTIFIER ::= { nonCriticalVoltage 2 }
nonCriticalOneVoltHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of 1V high has been detected."
::= { nonCriticalOneVolt 1 }
nonCriticalOneVoltLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of 1V low has been detected."
::= { nonCriticalOneVolt 2 }
nonCriticalTwoVolts OBJECT IDENTIFIER ::= { nonCriticalVoltage 3 }
nonCriticalTwoVoltsHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of 2V high has been detected."
::= { nonCriticalTwoVolts 1 }
nonCriticalTwoVoltsLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of 2V low has been detected."
::= { nonCriticalTwoVolts 2 }
nonCriticalThreeVolts OBJECT IDENTIFIER ::= { nonCriticalVoltage 4 }
nonCriticalThreeVoltsHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of 3V high has been detected."
::= { nonCriticalThreeVolts 1 }
nonCriticalThreeVoltsLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of 3V low has been detected."
::= { nonCriticalThreeVolts 2 }
nonCriticalThreeVoltsPci OBJECT IDENTIFIER ::= { nonCriticalVoltage 5 }
nonCriticalThreeVoltsPciHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of 3V high has been detected for the PCI."
::= { nonCriticalThreeVoltsPci 1 }
nonCriticalThreeVoltsPciLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of 3V low has been detected for the PCI."
::= { nonCriticalThreeVoltsPci 2 }
nonCriticalThreeVoltsStandby OBJECT IDENTIFIER ::= { nonCriticalVoltage 6 }
nonCriticalThreeVoltsStandbyHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of 3V standby high has been detected."
::= { nonCriticalThreeVoltsStandby 1 }
nonCriticalThreeVoltsStandbyLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of 3V standby low has been detected."
::= { nonCriticalThreeVoltsStandby 2 }
nonCriticalFiveVolts OBJECT IDENTIFIER ::= { nonCriticalVoltage 7 }
nonCriticalFiveVoltsHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of 5V high has been detected."
::= { nonCriticalFiveVolts 1 }
nonCriticalFiveVoltsLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of 5V low has been detected."
::= { nonCriticalFiveVolts 2 }
nonCriticalFiveVoltsPci OBJECT IDENTIFIER ::= { nonCriticalVoltage 8 }
nonCriticalFiveVoltsPciHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of 5V high has been detected for the PCI."
::= { nonCriticalFiveVoltsPci 1 }
nonCriticalFiveVoltsPciLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of 5V low has been detected for the PCI."
::= { nonCriticalFiveVoltsPci 2 }
nonCriticalFiveVoltsStandby OBJECT IDENTIFIER ::= { nonCriticalVoltage 9 }
nonCriticalFiveVoltsStandbyHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of 5V standby high has been detected."
::= { nonCriticalFiveVoltsStandby 1 }
nonCriticalFiveVoltsStandbyLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of 5V standby low has been detected."
::= { nonCriticalFiveVoltsStandby 2 }
nonCriticalNTwelveVolts OBJECT IDENTIFIER ::= { nonCriticalVoltage 10 }
nonCriticalNTwelveVoltsHigh NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of negative 12V high has been detected."
::= { nonCriticalNTwelveVolts 1 }
nonCriticalNTwelveVoltsLow NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
side, universalUniqueId }
STATUS current
DESCRIPTION
"A non-critical state of negative 12V low has been detected."
::= { nonCriticalNTwelveVolts 2 }
platform OBJECT IDENTIFIER ::= { mpaFamily 7 }
scalableNode OBJECT IDENTIFIER ::= { platform 1 }
scalableNodeMode OBJECT IDENTIFIER ::= { scalableNode 1 }
scalableNodeModeNullOrUnknown NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The scalable node is in a null or unknown mode."
::= { scalableNodeMode 1 }
scalableNodeModePrimary NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The scalable node is in primary mode."
::= { scalableNodeMode 2 }
scalableNodeModeSecondary NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The scalable node is in secondary mode."
::= { scalableNodeMode 3 }
scalableNodeModeStandalone NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The scalable node is now in standalone mode."
::= { scalableNodeMode 4 }
scalableNodeStandalone OBJECT IDENTIFIER ::= { scalableNode 2 }
standaloneMode OBJECT IDENTIFIER ::= { scalableNodeStandalone 1 }
primary NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The scalable node is now in standalone primary mode."
::= { standaloneMode 1 }
reset OBJECT IDENTIFIER ::= { standaloneMode 2 }
resetPrimary NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The scalable node is now in standalone primary reset mode."
::= { reset 1 }
resetSecondary NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The scalable node is now in standalone primary secondary mode."
::= { reset 2 }
secondary NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The scalable node is now in standalone secondary mode."
::= { standaloneMode 3 }
scalablePartition OBJECT IDENTIFIER ::= { platform 2 }
scalablePartitionAlert NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
alertCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The scalabel partition has generated an alert."
::= { scalablePartition 1 }
scalablePartitionState OBJECT IDENTIFIER ::= { scalablePartition 2 }
scalablePartitionNullOrUnknown NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The scalable partition state is 'null or unknown'."
::= { scalablePartitionState 1 }
scalablePartitionPoweredOff NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The scalable partition state is 'powered off'."
::= { scalablePartitionState 2 }
scalablePartitionPoweringOn NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The scalable partition state is 'powering on'."
::= { scalablePartitionState 3 }
scalablePartitionResetting NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The scalable partition state is 'resetting'."
::= { scalablePartitionState 4 }
scalablePartitionShuttingDown NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The scalable partition state is 'shutting down'."
::= { scalablePartitionState 5 }
system OBJECT IDENTIFIER ::= { mpaFamily 8 }
bootFailure NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
universalUniqueId }
STATUS current
DESCRIPTION
"The system indicated a boot failure."
::= { system 1 }
fuelGauge OBJECT IDENTIFIER ::= { system 2 }
fuelGaugeLowFuel NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
universalUniqueId }
STATUS current
DESCRIPTION
"The fuel gauge indicates low fuel."
::= { fuelGauge 1 }
fuelGaugeNotRedundant NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
universalUniqueId }
STATUS current
DESCRIPTION
"The fuel gauge indicates not redundant."
::= { fuelGauge 2 }
fuelGaugeOverCurrent NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
universalUniqueId }
STATUS current
DESCRIPTION
"The fuel gauge indicates over current."
::= { fuelGauge 3 }
systemLoaderTimeout NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
universalUniqueId }
STATUS current
DESCRIPTION
"The system loader has timed out."
::= { system 3 }
systemOsTimeout NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
universalUniqueId }
STATUS current
DESCRIPTION
"The operating system has timed out."
::= { system 4 }
systemPfa OBJECT IDENTIFIER ::= { system 5 }
fanSystemPfa NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
unitNumber, universalUniqueId }
STATUS current
DESCRIPTION
"The fan system has generated a PFA."
::= { systemPfa 1 }
systemPostTimeout NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
universalUniqueId }
STATUS current
DESCRIPTION
"The POST has timed out."
::= { system 6 }
systemPowerOff NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
universalUniqueId }
STATUS current
DESCRIPTION
"The sytsem has powered off."
::= { system 7 }
systemPowerOn NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
universalUniqueId }
STATUS current
DESCRIPTION
"The sytsem has powered on."
::= { system 8 }
systemRedundantPower NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
universalUniqueId }
STATUS current
DESCRIPTION
"The system is running on redundant power."
::= { system 9 }
systemTamper NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
universalUniqueId }
STATUS current
DESCRIPTION
"The system has been tampered with."
::= { system 10 }
unknown NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
STATUS current
DESCRIPTION
"The system is in an unknown state."
::= { mpaFamily 9 }
--
-- PET/ASF traps
--
petFamily OBJECT IDENTIFIER ::= { directorTraps 5 }
petFamilyEventDetails OBJECT IDENTIFIER ::= { petFamily 1 }
allVariableBindings OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"All of the variable bindings for this PET trap."
::= { petFamilyEventDetails 1 }
entity OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The entity of this PET event."
::= { petFamilyEventDetails 2 }
entityInstance OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The entity instance of this PET event."
::= { petFamilyEventDetails 3 }
petEventData OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The event data of this PET event."
::= { petFamilyEventDetails 4 }
petEventSeverity OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity of this PET event."
::= { petFamilyEventDetails 5 }
petEventSourceType OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The source type of this PET event."
::= { petFamilyEventDetails 6 }
petEventType OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the PET event."
::= { petFamilyEventDetails 7 }
guid OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The GUID for this PET event."
::= { petFamilyEventDetails 8 }
languageCode OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The language code for this PET event."
::= { petFamilyEventDetails 9 }
localTimeStamp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The local time stamp of this PET event."
::= { petFamilyEventDetails 10 }
manufacturerId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The manufacturer ID for the source of the PET event."
::= { petFamilyEventDetails 11 }
oemCustomField OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value for the OEM customer field of this PET event."
::= { petFamilyEventDetails 12 }
offset OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The offset for this PET event."
::= { petFamilyEventDetails 13 }
sensorDevice OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sensor device for this PET event."
::= { petFamilyEventDetails 14 }
sensorNumber OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sensor number for this PET event."
::= { petFamilyEventDetails 15 }
sensorType OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sensor type for this PET event."
::= { petFamilyEventDetails 16 }
sequenceId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sequence ID for this PET event."
::= { petFamilyEventDetails 17 }
systemId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system ID for this PET event."
::= { petFamilyEventDetails 18 }
trapSourceType OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The trap source type for this PET event."
::= { petFamilyEventDetails 19 }
utcOffset OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The UTC offset for this PET event."
::= { petFamilyEventDetails 20 }
petEnvironmental OBJECT IDENTIFIER ::= { petFamily 2 }
petEnvironmentalSensor OBJECT IDENTIFIER ::= { petEnvironmental 1 }
sensorCaseIntrusion NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
STATUS current
DESCRIPTION
"A sensor has detected a case intrusion."
::= { petEnvironmentalSensor 1 }
sensorCurrent NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
STATUS current
DESCRIPTION
"A sensor has detected a current change."
::= { petEnvironmentalSensor 2 }
sensorFan NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
STATUS current
DESCRIPTION
"A sensor has detected a fan change."
::= { petEnvironmentalSensor 3 }
sensorPowerSupply NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
STATUS current
DESCRIPTION
"A sensor has detected a power supply change."
::= { petEnvironmentalSensor 4 }
sensorTemperature NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
STATUS current
DESCRIPTION
"A sensor has detected a temperature change."
::= { petEnvironmentalSensor 5 }
sensorVoltage NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
STATUS current
DESCRIPTION
"A sensor has detected a voltage change."
::= { petEnvironmentalSensor 6 }
firmware OBJECT IDENTIFIER ::= { petFamily 3 }
bios OBJECT IDENTIFIER ::= { firmware 1 }
progress NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
STATUS current
DESCRIPTION
"The progress of the BIOS has changed."
::= { bios 1 }
hardware OBJECT IDENTIFIER ::= { petFamily 4 }
cableInterconnect NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
STATUS current
DESCRIPTION
"The cable/interconnect hardware has generated an event."
::= { hardware 1 }
drivebay NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
STATUS current
DESCRIPTION
"The monitor drivebay hardware has generated an event."
::= { hardware 2 }
moduleBoard NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
STATUS current
DESCRIPTION
"The monitor module/board hardware has generated an event."
::= { hardware 3 }
monitorAsicIc NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
STATUS current
DESCRIPTION
"The monitor ASIC/IC hardware has generated an event."
::= { hardware 4 }
network NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
STATUS current
DESCRIPTION
"The network hardware has generated an event."
::= { hardware 5 }
watchdog1 NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
STATUS current
DESCRIPTION
"The hardware has generated a watchdog 1 event."
::= { hardware 6 }
watchdog2 NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
STATUS current
DESCRIPTION
"The hardware has generated a watchdog 2 event."
::= { hardware 7 }
petFamilySystem OBJECT IDENTIFIER ::= { petFamily 5 }
petFamilySystemOs OBJECT IDENTIFIER ::= { petFamilySystem 1 }
petFamilySystemOsBoot NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
STATUS current
DESCRIPTION
"The operating system on the host has booted."
::= { petFamilySystemOs 1 }
petFamilySystemOsOperation OBJECT IDENTIFIER ::= { petFamilySystemOs 2 }
heartbeat NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
STATUS current
DESCRIPTION
"The operating system has generated a heartbeat event."
::= { petFamilySystemOsOperation 1 }
--
-- Storage traps
--
storageFamily OBJECT IDENTIFIER ::= { directorTraps 6 }
serveRaidController OBJECT IDENTIFIER ::= { storageFamily 1 }
physicalDrive OBJECT IDENTIFIER ::= { serveRaidController 1 }
vendorUnsupported NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
STATUS current
DESCRIPTION
"The vendor for this physical drive is unsupported."
::= { physicalDrive 1 }
state OBJECT IDENTIFIER ::= { serveRaidController 2 }
notFound NOTIFICATION-TYPE
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
STATUS current
DESCRIPTION
"No controllers were found in this system."
::= { state 1 }
--
-- The trap description objects
--
trapType OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the event."
::= { description 1 }
trapSeverity OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity of the event."
::= { description 2 }
trapSenderName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system name from which the event was sent."
::= { description 3 }
trapManagedObjectName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system name for which the event was generated."
::= { description 4 }
trapText OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Text associated with the event."
::= { description 5 }
trapCategory OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The category of the event."
::= { description 6 }
--
-- Trap detail types
--
-- NOTE:
--
-- When viewing a trap holding an event detail type, the number following these
-- OIDs refer to different values of this type. They increment according to
-- each trap, ergo, you should never see a { char 2 } without a { char 1 }.
--
char OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Eight bit unsigned event detail."
::= { details 1 }
short OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sixteen bit signed event detail."
::= { details 2 }
int OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Thirty-two bit signed event detail."
::= { details 3 }
long OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sixty-four bit signed event detail."
::= { details 4 }
boolean OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Thirty-two bit unsigned event detail."
::= { details 5 }
float OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Thirty-two bit decimal pointed event detail."
::= { details 6 }
double OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sixty-four bit decimal pointed event detail."
::= { details 7 }
octet OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A string of bytes holding an event detail."
::= { details 8 }
string OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A string of unicode chars (normal text) holding
an event detail."
::= { details 9 }
dateTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Date and time since 1/1970 as an event
detail."
::= { details 10 }
uniChar OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unicode char holding an event detail."
::= { details 11 }
byte OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"One byte holding an event detail."
::= { details 12 }
directorTrapsConformance OBJECT IDENTIFIER ::= { directorTraps 100 }
directorTrapsGroups OBJECT IDENTIFIER ::= { directorTrapsConformance 1 }
directorTrapsCompliances OBJECT IDENTIFIER ::= { directorTrapsConformance 2 }
directorTrapsCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for this module."
MODULE -- this module
MANDATORY-GROUPS { directorTrapsGroup, directorNotificationsGroup }
::= { directorTrapsCompliances 1 }
directorTrapsGroup OBJECT-GROUP
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText,
trapCategory, char, short, int, long, boolean, float, octet, double, string, dateTime,
uniChar, byte, actualValue, duration, monitorResource, thresholdName, thresholdValue,
userID, address, userName, userDescription, userLocale, category, categoryString,
computerName, data, eventLogCode, eventLogIdentifier, eventLogType, insertionStrings,
logFile, message, recordNumber, sourceName, type, user, acceptPause, acceptStop,
caption, checkPoint, creationClassName, serviceDescription, desktopInteract,
displayName, errorControl, exitCode, name, pathName, processId, serviceSpecificExitCode,
serviceType, startMode, startName, started, serviceState, status,
systemCreationClassName, systemName, tagId, waitHint, hive, rootPath, securityDescriptor,
timeCreated, alertCode, busId, componentId, firmwareCode, ipAddress1, ipAddress2, issue,
powerDomain, reason, scsiId, side, newState, temperatureSensor, threshold,
universalUniqueId, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber,
voltageSensor, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity,
petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId,
oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId,
trapSourceType, utcOffset }
STATUS current
DESCRIPTION
"The objects group for objects defined in this module."
::= { directorTrapsGroups 1 }
directorNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS { generalEvent, online, offline, create, change, destroy, processMonitor,
cpuUtilization, processCount, driveSpaceUsed, driveSpaceUsedPercent,
driveSpaceRemaining, driveWorkload, lockedMemory, memoryUsage,
totalPrivilegedTimePercent, fileReadOperationsPerSec, udpPacketsSentPerSec,
udpPacketsReceivedPerSec, ipPacketsSentPerSec, ipPacketsReceivedPerSec,
ipErrorPacketsReceivedPerSec, tcpConnections, action, badPassword,
badUserID, disabledUserID, downlevelConsole, expiredPassword, tooManyActiveIDs,
tooManyActiveLogons, uplevelConsole, logoff, logon, applicationLog, securityLog,
systemLog, startedService, stoppedService, softwareTreeChanged, systemTreeChanged,
codEnabled, bladeServerCommunication, bladeServerInserted, bladeServerRemoved,
busCommunication, chassisConfiguration, chassisFailed, dasdFailed, dasdInserted,
dasdRemoved, memoryFailed, componentFanFailed, componentFanInserted, componentFanPfa,
componentFanRemoved, hardwareCrashDumpAborted, hardwareCrashDumpCompleted,
hardwareCrashDumpInitiated, ioModuleConfiguration, ioModuleFailed, ioModuleInserted,
ioModulePost, ioModulePowerOn, ioModulePowerOff, ioModuleRedundancy, ioModuleRemoved,
kvmOwner, osImageCrashDumpAborted, osImageCrashDumpCompleted, osImageCrashDumpInitiated,
componentPfa, powerSubsystemLowFuel, powerSubsystemOverCurrent, powerSubsystemOverPower,
powerSubsystemRedundancy, powerSupplyFailed, powerSupplyInserted, powerSupplyRemoved,
serverPowerOff, serverPowerOn, serverPowerState, serviceProcessorActive,
serviceProcessorConfiguration, serviceProcessorInserted, serviceProcessorLog,
serviceProcessorNetworkStack, serviceProcessorRedundancy, serviceProcessorRemoteLogin,
serviceProcessorRemoved, serviceProcessorRestart, serviceProcessorTest,
smpExpansionModuleDisabled, usbInserted, usbOwner, usbRemoved, vrmFailed, hardDiskDrive,
multipleFanFailure, powerFailureEpow, powerFailureFailed, powerFailureRemoved,
criticalTamper, criticalTemperatureAmbient, criticalTemperaturePci,
criticalTemperaturePlanar, criticalTwelveVoltsHigh, criticalTwelveVoltsLow,
criticalTwelveVoltsFaultA, criticalTwelveVoltsFaultB, criticalTwelveVoltsFaultC,
criticalTwelveVoltsFaultD, criticalOneVoltHigh, criticalOneVoltLow,
criticalTwoVoltsHigh, criticalTwoVoltsLow, criticalThreeVoltsHigh,
criticalThreeVoltsLow, criticalThreeVoltsPciHigh, criticalThreeVoltsPciLow,
criticalThreeVoltsStandbyHigh, criticalThreeVoltsStandbyLow, criticalFiveVoltsHigh,
criticalFiveVoltsLow, criticalFiveVoltsFaultHigh, criticalFiveVoltsFaultLow,
criticalFiveVoltsPciHigh, criticalFiveVoltsPciLow, criticalFiveVoltsStandbyHigh,
criticalFiveVoltsStandbyLow, criticalNTwelveVoltsHigh, criticalNTwelveVoltsLow,
voltageRegulatorModuleFailure, deploymentBoot, deploymentLoader, deploymentOs,
deploymentPost, environmentalTemperature, environmentalVoltage, nonCriticalFanRemoved,
redundantPower, singleFanFailure, nonCriticalTemperatureAmbient, nonCriticalTemperaturePci,
nonCriticalTemperaturePlanar, nonCriticalTwelveVoltsHigh, nonCriticalTwelveVoltsLow,
nonCriticalOneVoltHigh, nonCriticalOneVoltLow, nonCriticalTwoVoltsHigh, nonCriticalTwoVoltsLow,
nonCriticalThreeVoltsHigh, nonCriticalThreeVoltsLow, nonCriticalThreeVoltsPciHigh,
nonCriticalThreeVoltsPciLow, nonCriticalThreeVoltsStandbyHigh, nonCriticalThreeVoltsStandbyLow,
nonCriticalFiveVoltsHigh, nonCriticalFiveVoltsLow, nonCriticalFiveVoltsPciHigh,
nonCriticalFiveVoltsPciLow, nonCriticalFiveVoltsStandbyHigh, nonCriticalFiveVoltsStandbyLow,
nonCriticalNTwelveVoltsHigh, nonCriticalNTwelveVoltsLow, scalableNodeModeNullOrUnknown,
scalableNodeModePrimary, scalableNodeModeSecondary, scalableNodeModeStandalone, primary, resetPrimary,
resetSecondary, secondary, scalablePartitionAlert, scalablePartitionNullOrUnknown,
scalablePartitionPoweredOff, scalablePartitionPoweringOn, scalablePartitionResetting,
scalablePartitionShuttingDown, bootFailure, fuelGaugeLowFuel, fuelGaugeNotRedundant, fuelGaugeOverCurrent,
systemLoaderTimeout, systemOsTimeout, fanSystemPfa, systemPostTimeout, systemPowerOff,
systemPowerOn, systemRedundantPower, systemTamper, unknown, sensorCaseIntrusion,
sensorCurrent, sensorFan, sensorPowerSupply, sensorTemperature, sensorVoltage,
progress, cableInterconnect, drivebay, moduleBoard, monitorAsicIc, network, watchdog1,
watchdog2, petFamilySystemOsBoot, heartbeat, vendorUnsupported, notFound }
STATUS current
DESCRIPTION
"The notification group for notifications defined in this module."
::= { directorTrapsGroups 2 }
END