IBM-Director-Alert-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
|
|
Integer32 FROM SNMPv2-SMI
|
|
DisplayString, TruthValue FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF
|
|
SnmpAdminString FROM SNMP-FRAMEWORK-MIB;
|
|
|
|
ibm OBJECT IDENTIFIER ::= { enterprises 2 }
|
|
|
|
ibmProd OBJECT IDENTIFIER ::= { ibm 6 }
|
|
|
|
director OBJECT IDENTIFIER ::= { ibmProd 159 }
|
|
|
|
description OBJECT IDENTIFIER ::= { director 202 }
|
|
|
|
details OBJECT IDENTIFIER ::= { director 9696 }
|
|
|
|
directorTraps MODULE-IDENTITY
|
|
LAST-UPDATED "200404210000Z"
|
|
ORGANIZATION "IBM Corp."
|
|
CONTACT-INFO
|
|
"IBM Corporation"
|
|
DESCRIPTION
|
|
"This MIB is for use with the Event Action Plan Builder of
|
|
IBM Director."
|
|
REVISION "200404210000Z"
|
|
DESCRIPTION
|
|
"This MIB was revised to include traps for more possible
|
|
events generated by the IBM Director event subsystem."
|
|
REVISION "200307090000Z"
|
|
DESCRIPTION
|
|
"The initial version of this MIB."
|
|
::= { director 201 }
|
|
|
|
--
|
|
-- Generic trap for events
|
|
--
|
|
generalEvent NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a IBM Director event converted into an SNMP trap.
|
|
This trap is only used for events with no mapping."
|
|
::= { directorTraps 2 }
|
|
|
|
--
|
|
-- Topology traps
|
|
--
|
|
|
|
directorFamily OBJECT IDENTIFIER ::= { directorTraps 1 }
|
|
|
|
topology OBJECT IDENTIFIER ::= { directorFamily 1 }
|
|
|
|
online NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The managed object's state has changed to online."
|
|
::= { topology 1 }
|
|
|
|
offline NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The managed object's state has changed to offline."
|
|
::= { topology 2 }
|
|
|
|
create NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The managed object has been created."
|
|
::= { topology 3 }
|
|
|
|
change NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The managed object has changed."
|
|
::= { topology 4 }
|
|
|
|
destroy NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The managed object has been destroyed."
|
|
::= { topology 5 }
|
|
|
|
--
|
|
-- Director Agent traps
|
|
--
|
|
|
|
directorAgent OBJECT IDENTIFIER ::= { directorFamily 2 }
|
|
|
|
processMonitor NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
actualValue, duration, monitorResource, thresholdName, thresholdValue }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The process monitor threshold has generated
|
|
an event."
|
|
::= { directorAgent 1 }
|
|
|
|
cpuMonitors OBJECT IDENTIFIER ::= { directorAgent 2 }
|
|
|
|
cpuUtilization NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
actualValue, duration, monitorResource, thresholdName, thresholdValue }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU utilization monitor threshold has generated
|
|
an event."
|
|
::= { cpuMonitors 1 }
|
|
|
|
processCount NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
actualValue, duration, monitorResource, thresholdName, thresholdValue }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The process count monitor threshold has generated
|
|
an event."
|
|
::= { cpuMonitors 2 }
|
|
|
|
diskMonitors OBJECT IDENTIFIER ::= { directorAgent 3 }
|
|
|
|
driveSpaceUsed NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
actualValue, duration, monitorResource, thresholdName, thresholdValue }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The drive space used monitor threshold has generated
|
|
an event."
|
|
::= { diskMonitors 1 }
|
|
|
|
driveSpaceUsedPercent NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
actualValue, duration, monitorResource, thresholdName, thresholdValue }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of drive space used monitor threshold has generated
|
|
an event."
|
|
::= { diskMonitors 2 }
|
|
|
|
driveSpaceRemaining NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
actualValue, duration, monitorResource, thresholdName, thresholdValue }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The drive space remaining monitor threshold has generated
|
|
an event."
|
|
::= { diskMonitors 3 }
|
|
|
|
driveWorkload NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
actualValue, duration, monitorResource, thresholdName, thresholdValue }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The drive workload monitor threshold has generated
|
|
an event."
|
|
::= { diskMonitors 4 }
|
|
|
|
memoryMonitors OBJECT IDENTIFIER ::= { directorAgent 4 }
|
|
|
|
lockedMemory NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
actualValue, duration, monitorResource, thresholdName, thresholdValue }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The locked memory monitor threshold has generated
|
|
an event."
|
|
::= { memoryMonitors 1 }
|
|
|
|
memoryUsage NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
actualValue, duration, monitorResource, thresholdName, thresholdValue }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage monitor threshold has generated
|
|
an event."
|
|
::= { memoryMonitors 2 }
|
|
|
|
nicMonitors OBJECT IDENTIFIER ::= { directorAgent 5 }
|
|
|
|
-- Add nic monitors here
|
|
|
|
ntPerfMonitors OBJECT IDENTIFIER ::= { directorAgent 6 }
|
|
|
|
totalPrivilegedTimePercent NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
actualValue, duration, monitorResource, thresholdName, thresholdValue }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of total privileged time monitor
|
|
threshold has generated an event."
|
|
::= { ntPerfMonitors 1 }
|
|
|
|
fileReadOperationsPerSec NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
actualValue, duration, monitorResource, thresholdName, thresholdValue }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The files read per second monitor threshold has
|
|
generated an event."
|
|
::= { ntPerfMonitors 2 }
|
|
|
|
-- thread NOTIFICATION-TYPE
|
|
-- OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- ""
|
|
--::= { ntPerfMonitor 3 }
|
|
|
|
tcpipMonitors OBJECT IDENTIFIER ::= { directorAgent 7 }
|
|
|
|
udpPacketsSentPerSec NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
actualValue, duration, monitorResource, thresholdName, thresholdValue }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A threshold event for the number of UDP packets
|
|
sent per second."
|
|
::= { tcpipMonitors 1 }
|
|
|
|
udpPacketsReceivedPerSec NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
actualValue, duration, monitorResource, thresholdName, thresholdValue }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A threshold event for the number of UDP packets
|
|
received per second."
|
|
::= { tcpipMonitors 2 }
|
|
|
|
ipPacketsSentPerSec NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
actualValue, duration, monitorResource, thresholdName, thresholdValue }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A threshold event for the number of IP packets
|
|
sent per second."
|
|
::= { tcpipMonitors 3 }
|
|
|
|
ipPacketsReceivedPerSec NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
actualValue, duration, monitorResource, thresholdName, thresholdValue }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A threshold event for the number of IP packets
|
|
received per second."
|
|
::= { tcpipMonitors 4 }
|
|
|
|
ipErrorPacketsReceivedPerSec NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
actualValue, duration, monitorResource, thresholdName, thresholdValue }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A threshold event for the number of IP packets
|
|
received with errors per second."
|
|
::= { tcpipMonitors 5 }
|
|
|
|
tcpConnections NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
actualValue, duration, monitorResource, thresholdName, thresholdValue }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A threshold event for the number of TCP connections."
|
|
::= { tcpipMonitors 6 }
|
|
|
|
monitorEventDetails OBJECT IDENTIFIER ::= { directorAgent 8 }
|
|
|
|
actualValue OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual value of the monitor."
|
|
::= { monitorEventDetails 1 }
|
|
|
|
duration OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The duration of this monitor."
|
|
::= { monitorEventDetails 2 }
|
|
|
|
monitorResource OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The monitor resource."
|
|
::= { monitorEventDetails 3 }
|
|
|
|
thresholdName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the monitor threshold."
|
|
::= { monitorEventDetails 4 }
|
|
|
|
thresholdValue OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of the monitor threshold."
|
|
::= { monitorEventDetails 5 }
|
|
|
|
|
|
--
|
|
-- Test trap
|
|
--
|
|
test OBJECT IDENTIFIER ::= { directorFamily 3 }
|
|
|
|
action NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test action event. An internally generated event
|
|
for the purpose of testing the action configuration."
|
|
::= { test 1 }
|
|
|
|
--
|
|
-- Console traps
|
|
--
|
|
console OBJECT IDENTIFIER ::= { directorFamily 4 }
|
|
|
|
consoleEventDetails OBJECT IDENTIFIER ::= { console 1 }
|
|
|
|
userID OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The console user ID."
|
|
::= { consoleEventDetails 1 }
|
|
|
|
address OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The console address."
|
|
::= { consoleEventDetails 2 }
|
|
|
|
userName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The console username."
|
|
::= { consoleEventDetails 3 }
|
|
|
|
userDescription OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The console username's description."
|
|
::= { consoleEventDetails 4 }
|
|
|
|
userLocale OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The console user's locale."
|
|
::= { consoleEventDetails 5 }
|
|
|
|
logonFailure OBJECT IDENTIFIER ::= { console 2 }
|
|
|
|
badPassword NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
userID, address }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When attempting to logon to the console,
|
|
a bad password was used."
|
|
::= { logonFailure 1 }
|
|
|
|
badUserID NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
userID, address }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When attempting to logon to the console,
|
|
a bad user ID was used."
|
|
::= { logonFailure 2 }
|
|
|
|
disabledUserID NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
userID, address }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When attempting to logon to the console,
|
|
a disabled user ID was used."
|
|
::= { logonFailure 3 }
|
|
|
|
downlevelConsole NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
userID, address }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When attempting to logon to the console,
|
|
a downlevel console was used."
|
|
::= { logonFailure 4 }
|
|
|
|
expiredPassword NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
userID, address }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When attempting to logon to the console,
|
|
an expired password was used."
|
|
::= { logonFailure 5 }
|
|
|
|
tooManyActiveIDs NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
userID, address }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When attempting to logon to the console,
|
|
too many IDs were active."
|
|
::= { logonFailure 6 }
|
|
|
|
tooManyActiveLogons NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
userID, address }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When attempting to logon to the console,
|
|
too many logons were active."
|
|
::= { logonFailure 7 }
|
|
|
|
uplevelConsole NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
userID, address }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When attempting to logon to the console,
|
|
an uplevel console was used."
|
|
::= { logonFailure 8 }
|
|
|
|
logoff NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
userID, address, userName, userDescription, userLocale }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A user has logged off the console."
|
|
::= { console 3 }
|
|
|
|
logon NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
userID, address, userName, userDescription, userLocale }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A user has logged on the console."
|
|
::= { console 4 }
|
|
|
|
--
|
|
-- CIM traps
|
|
--
|
|
cimFamily OBJECT IDENTIFIER ::= { directorTraps 3 }
|
|
|
|
windowsNTEventLog OBJECT IDENTIFIER ::= { cimFamily 1 }
|
|
|
|
windowsNTEventLogEventDetails OBJECT IDENTIFIER ::= { windowsNTEventLog 1 }
|
|
|
|
category OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows Event Log category."
|
|
::= { windowsNTEventLogEventDetails 1 }
|
|
|
|
categoryString OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows Event Log category string."
|
|
::= { windowsNTEventLogEventDetails 2 }
|
|
|
|
computerName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The computer name of the Windows Event Log event."
|
|
::= { windowsNTEventLogEventDetails 3 }
|
|
|
|
data OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows Event Log data for the event."
|
|
::= { windowsNTEventLogEventDetails 4 }
|
|
|
|
eventLogCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows Event Log numeric event ID."
|
|
::= { windowsNTEventLogEventDetails 5 }
|
|
|
|
eventLogIdentifier OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows Event Log numeric event identifier."
|
|
::= { windowsNTEventLogEventDetails 6 }
|
|
|
|
eventLogType OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows Event Log numeric event type."
|
|
::= { windowsNTEventLogEventDetails 7 }
|
|
|
|
insertionStrings OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows Event Log insertion strings."
|
|
::= { windowsNTEventLogEventDetails 8 }
|
|
|
|
logFile OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows Event Log file name."
|
|
::= { windowsNTEventLogEventDetails 9 }
|
|
|
|
message OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows Event Log message string."
|
|
::= { windowsNTEventLogEventDetails 10 }
|
|
|
|
recordNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows Event Log record number."
|
|
::= { windowsNTEventLogEventDetails 11 }
|
|
|
|
sourceName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows Event Log source name."
|
|
::= { windowsNTEventLogEventDetails 12 }
|
|
|
|
type OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows Event Log type."
|
|
::= { windowsNTEventLogEventDetails 13 }
|
|
|
|
user OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows Event Log user."
|
|
::= { windowsNTEventLogEventDetails 14 }
|
|
|
|
applicationLog NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
category, categoryString, computerName, data, eventLogCode, eventLogIdentifier, eventLogType,
|
|
insertionStrings, logFile, message, recordNumber, sourceName, type, user }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows NT application event log has changed."
|
|
::= { windowsNTEventLog 2 }
|
|
|
|
securityLog NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
category, categoryString, computerName, data, eventLogCode, eventLogIdentifier, eventLogType,
|
|
insertionStrings, logFile, message, recordNumber, sourceName, type, user }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows NT application security log has changed."
|
|
::= { windowsNTEventLog 3 }
|
|
|
|
systemLog NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows NT application system log has changed."
|
|
::= { windowsNTEventLog 4 }
|
|
|
|
windowsNTService OBJECT IDENTIFIER ::= { cimFamily 2 }
|
|
|
|
windowsNTServiceEventDetails OBJECT IDENTIFIER ::= { windowsNTService 1 }
|
|
|
|
acceptPause OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Whether this service accepts the pause state change."
|
|
::= { windowsNTServiceEventDetails 1 }
|
|
|
|
acceptStop OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Whether this service accepts the stop state change."
|
|
::= { windowsNTServiceEventDetails 2 }
|
|
|
|
caption OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The caption string for this service."
|
|
::= { windowsNTServiceEventDetails 3 }
|
|
|
|
checkPoint OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service's check point."
|
|
::= { windowsNTServiceEventDetails 4 }
|
|
|
|
creationClassName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The creation class name for the service."
|
|
::= { windowsNTServiceEventDetails 5 }
|
|
|
|
serviceDescription OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The description of the service."
|
|
::= { windowsNTServiceEventDetails 6 }
|
|
|
|
desktopInteract OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Whether the service interacts with the desktop."
|
|
::= { windowsNTServiceEventDetails 7 }
|
|
|
|
displayName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The displayable name for the service."
|
|
::= { windowsNTServiceEventDetails 8 }
|
|
|
|
errorControl OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The error control value for the service."
|
|
::= { windowsNTServiceEventDetails 9 }
|
|
|
|
exitCode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The exit code of the process for the service."
|
|
::= { windowsNTServiceEventDetails 10 }
|
|
|
|
name OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the service."
|
|
::= { windowsNTServiceEventDetails 11 }
|
|
|
|
pathName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The path name for the service."
|
|
::= { windowsNTServiceEventDetails 12 }
|
|
|
|
processId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The process ID of the running service."
|
|
::= { windowsNTServiceEventDetails 13 }
|
|
|
|
serviceSpecificExitCode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specific exit code for the service."
|
|
::= { windowsNTServiceEventDetails 14 }
|
|
|
|
serviceType OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of service."
|
|
::= { windowsNTServiceEventDetails 15 }
|
|
|
|
startMode OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The start mode for the service."
|
|
::= { windowsNTServiceEventDetails 16 }
|
|
|
|
startName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The start name for the service."
|
|
::= { windowsNTServiceEventDetails 17 }
|
|
|
|
started OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Whether this service has started."
|
|
::= { windowsNTServiceEventDetails 18 }
|
|
|
|
serviceState OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of the service."
|
|
::= { windowsNTServiceEventDetails 19 }
|
|
|
|
status OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the service."
|
|
::= { windowsNTServiceEventDetails 20 }
|
|
|
|
systemCreationClassName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system creation class name for the service."
|
|
::= { windowsNTServiceEventDetails 21 }
|
|
|
|
systemName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system name for the service."
|
|
::= { windowsNTServiceEventDetails 22 }
|
|
|
|
tagId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tag ID of the service."
|
|
::= { windowsNTServiceEventDetails 23 }
|
|
|
|
waitHint OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of the wait hint for the service."
|
|
::= { windowsNTServiceEventDetails 24 }
|
|
|
|
startedService NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
acceptPause, acceptStop, caption, checkPoint, creationClassName, serviceDescription,
|
|
desktopInteract, displayName, errorControl, exitCode, name, pathName, processId,
|
|
serviceSpecificExitCode, serviceType, startMode, startName, started, serviceState,
|
|
status, systemCreationClassName, systemName, tagId, waitHint }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Windows NT service has started."
|
|
::= { windowsNTService 2 }
|
|
|
|
stoppedService NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
acceptPause, acceptStop, caption, checkPoint, creationClassName, serviceDescription,
|
|
desktopInteract, displayName, errorControl, exitCode, name, pathName, processId,
|
|
serviceSpecificExitCode, serviceType, startMode, startName, started, serviceState,
|
|
status, systemCreationClassName, systemName, tagId, waitHint }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Windows NT service has stopped."
|
|
::= { windowsNTService 3 }
|
|
|
|
windowsRegistry OBJECT IDENTIFIER ::= { cimFamily 3 }
|
|
|
|
windowsRegistryEventDetails OBJECT IDENTIFIER ::= { windowsRegistry 1 }
|
|
|
|
hive OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows Registry hive for this event."
|
|
::= { windowsRegistryEventDetails 1 }
|
|
|
|
rootPath OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows Registry root path for this event."
|
|
::= { windowsRegistryEventDetails 2 }
|
|
|
|
securityDescriptor OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows Registry security descriptor for this event."
|
|
::= { windowsRegistryEventDetails 3 }
|
|
|
|
timeCreated OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time this item was created in the Windows Registry."
|
|
::= { windowsRegistryEventDetails 4 }
|
|
|
|
softwareTreeChanged NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
hive, rootPath, securityDescriptor, timeCreated }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows software tree section of the registry
|
|
has changed."
|
|
::= { windowsRegistry 2 }
|
|
|
|
systemTreeChanged NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
hive, rootPath, securityDescriptor, timeCreated }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Windows system tree section of the registry
|
|
has changed."
|
|
::= { windowsRegistry 3 }
|
|
|
|
|
|
--
|
|
-- MPA traps
|
|
--
|
|
|
|
mpaFamily OBJECT IDENTIFIER ::= { directorTraps 4 }
|
|
|
|
mpaEventDetails OBJECT IDENTIFIER ::= { mpaFamily 1 }
|
|
|
|
alertCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The alert code."
|
|
::= { mpaEventDetails 1 }
|
|
|
|
busId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bus ID."
|
|
::= { mpaEventDetails 2 }
|
|
|
|
componentId OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component ID."
|
|
::= { mpaEventDetails 3 }
|
|
|
|
firmwareCode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The firmware identification code."
|
|
::= { mpaEventDetails 4 }
|
|
|
|
ipAddress1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The first IP address."
|
|
::= { mpaEventDetails 5 }
|
|
|
|
ipAddress2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The second IP address."
|
|
::= { mpaEventDetails 6 }
|
|
|
|
issue OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The issue for the event."
|
|
::= { mpaEventDetails 7 }
|
|
|
|
powerDomain OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The domain of the power supply."
|
|
::= { mpaEventDetails 8 }
|
|
|
|
reason OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The reason for the event."
|
|
::= { mpaEventDetails 9 }
|
|
|
|
scsiId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ID of the SCSI device."
|
|
::= { mpaEventDetails 10 }
|
|
|
|
side OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The side in which the event occured."
|
|
::= { mpaEventDetails 11 }
|
|
|
|
newState OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The new state."
|
|
::= { mpaEventDetails 12 }
|
|
|
|
temperatureSensor OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current temperature."
|
|
::= { mpaEventDetails 13 }
|
|
|
|
threshold OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The threshold for the event."
|
|
::= { mpaEventDetails 14 }
|
|
|
|
universalUniqueId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The universal unique ID."
|
|
::= { mpaEventDetails 15 }
|
|
|
|
senderUniversalUniqueId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The universal unique ID of the sender."
|
|
::= { mpaEventDetails 16 }
|
|
|
|
sourceUniversalUniqueId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The universal unique ID of the source."
|
|
::= { mpaEventDetails 17 }
|
|
|
|
unitNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unit number."
|
|
::= { mpaEventDetails 18 }
|
|
|
|
voltageSensor OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The voltage sensor."
|
|
::= { mpaEventDetails 19 }
|
|
|
|
component OBJECT IDENTIFIER ::= { mpaFamily 2 }
|
|
|
|
bladeServer OBJECT IDENTIFIER ::= { component 1 }
|
|
|
|
coD OBJECT IDENTIFIER ::= { bladeServer 1 }
|
|
|
|
codEnabled NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CoD has been enabled."
|
|
::= { coD 1 }
|
|
|
|
bladeServerCommunication NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Communication with a blade has been established."
|
|
::= { bladeServer 2 }
|
|
|
|
bladeServerInserted NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A blade has been inserted."
|
|
::= { bladeServer 3 }
|
|
|
|
bladeServerRemoved NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A blade has been removed."
|
|
::= { bladeServer 4 }
|
|
|
|
bus OBJECT IDENTIFIER ::= { component 2 }
|
|
|
|
busCommunication NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
busId, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Communication with a bus has been established."
|
|
::= { bus 1 }
|
|
|
|
chassis OBJECT IDENTIFIER ::= { component 3 }
|
|
|
|
chassisConfiguration NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
componentId, firmwareCode, issue, powerDomain, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The blade chassis configuration has changed."
|
|
::= { chassis 1 }
|
|
|
|
chassisFailed NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, issue, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The blade chassis has failed."
|
|
::= { chassis 2 }
|
|
|
|
dasd OBJECT IDENTIFIER ::= { component 4 }
|
|
|
|
dasdFailed NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, scsiId, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"a direct access storage device has failed."
|
|
::= { dasd 1 }
|
|
|
|
dasdInserted NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, scsiId, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A direct access storage device has been inserted."
|
|
::= { dasd 2 }
|
|
|
|
dasdRemoved NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, scsiId, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A direct access storage device has been removed."
|
|
::= { dasd 3 }
|
|
|
|
memory OBJECT IDENTIFIER ::= { component 5 }
|
|
|
|
memoryFailed NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Some memory has failed."
|
|
::= { memory 1 }
|
|
|
|
componentFan OBJECT IDENTIFIER ::= { component 6 }
|
|
|
|
componentFanFailed NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A fan has failed."
|
|
::= { componentFan 1 }
|
|
|
|
componentFanInserted NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A fan has been inserted."
|
|
::= { componentFan 2 }
|
|
|
|
componentFanPfa NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The fan component has generated a PFA."
|
|
::= { componentFan 3 }
|
|
|
|
componentFanRemoved NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A fan has been removed."
|
|
::= { componentFan 4 }
|
|
|
|
hardwareInformation OBJECT IDENTIFIER ::= { component 7 }
|
|
|
|
hardwareCrashDump OBJECT IDENTIFIER ::= { hardwareInformation 1 }
|
|
|
|
hardwareCrashDumpAborted NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A hardware crash dump was aborted."
|
|
::= { hardwareCrashDump 1 }
|
|
|
|
hardwareCrashDumpCompleted NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A hardware crash dump has completed."
|
|
::= { hardwareCrashDump 2 }
|
|
|
|
hardwareCrashDumpInitiated NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A hardware crash dump has been initiated."
|
|
::= { hardwareCrashDump 3 }
|
|
|
|
ioModule OBJECT IDENTIFIER ::= { component 8 }
|
|
|
|
ioModuleConfiguration NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, ipAddress1, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An I/O module's configuration has changed."
|
|
::= { ioModule 1 }
|
|
|
|
ioModuleFailed NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An I/O module has failed."
|
|
::= { ioModule 2 }
|
|
|
|
ioModuleInserted NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An I/O module has been inserted."
|
|
::= { ioModule 3 }
|
|
|
|
ioModulePost NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An I/O module has past POST."
|
|
::= { ioModule 4 }
|
|
|
|
ioModulePower OBJECT IDENTIFIER ::= { ioModule 5 }
|
|
|
|
ioModulePowerOn NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An I/O module has been powered on."
|
|
::= { ioModulePower 1 }
|
|
|
|
ioModulePowerOff NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An I/O module has been powered off."
|
|
::= { ioModulePower 2 }
|
|
|
|
ioModuleRedundancy NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An I/O module is a redundancy."
|
|
::= { ioModule 6 }
|
|
|
|
ioModuleRemoved NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An I/O module has been removed."
|
|
::= { ioModule 7 }
|
|
|
|
kvm OBJECT IDENTIFIER ::= { component 9 }
|
|
|
|
kvmOwner NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The KVM owner has changed."
|
|
::= { kvm 1 }
|
|
|
|
osImage OBJECT IDENTIFIER ::= { component 10 }
|
|
|
|
osImageCrashDump OBJECT IDENTIFIER ::= { osImage 1 }
|
|
|
|
osImageCrashDumpAborted NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operating system image crash dump was aborted."
|
|
::= { osImageCrashDump 1 }
|
|
|
|
osImageCrashDumpCompleted NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operating system image crash dump has completed."
|
|
::= { osImageCrashDump 2 }
|
|
|
|
osImageCrashDumpInitiated NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operating system image crash dump has been initiated."
|
|
::= { osImageCrashDump 3 }
|
|
|
|
componentPfa NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A component has generated a PFA."
|
|
::= { component 11 }
|
|
|
|
powerSubsystem OBJECT IDENTIFIER ::= { component 12 }
|
|
|
|
powerSubsystemLowFuel NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power subsystem indicates low fuel."
|
|
::= { powerSubsystem 1 }
|
|
|
|
powerSubsystemOverCurrent NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power subsystem indicates over current."
|
|
::= { powerSubsystem 2 }
|
|
|
|
powerSubsystemOverPower NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power subsystem indicates over power."
|
|
::= { powerSubsystem 3 }
|
|
|
|
powerSubsystemRedundancy NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power subsystem indicates a redundancy."
|
|
::= { powerSubsystem 4 }
|
|
|
|
powerSupply OBJECT IDENTIFIER ::= { component 13 }
|
|
|
|
powerSupplyFailed NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, reason, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A power supply has failed."
|
|
::= { powerSupply 1 }
|
|
|
|
powerSupplyInserted NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A power supply has been inserted."
|
|
::= { powerSupply 2 }
|
|
|
|
powerSupplyRemoved NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A power supply has been removed."
|
|
::= { powerSupply 3 }
|
|
|
|
server OBJECT IDENTIFIER ::= { component 14 }
|
|
|
|
serverPower OBJECT IDENTIFIER ::= { server 1 }
|
|
|
|
serverPowerOff NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The server has powered off."
|
|
::= { serverPower 1 }
|
|
|
|
serverPowerOn NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The server has powered on."
|
|
::= { serverPower 2 }
|
|
|
|
serverPowerState NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, newState, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The server's power state has changed."
|
|
::= { server 2 }
|
|
|
|
serviceProcessor OBJECT IDENTIFIER ::= { component 15 }
|
|
|
|
serviceProcessorActive NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A service processor is now active."
|
|
::= { serviceProcessor 1 }
|
|
|
|
serviceProcessorConfiguration NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A service processor configuration has changed."
|
|
::= { serviceProcessor 2 }
|
|
|
|
serviceProcessorInserted NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A service processor has been inserted."
|
|
::= { serviceProcessor 3 }
|
|
|
|
serviceProcessorLog NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A service processor has generated a log."
|
|
::= { serviceProcessor 4 }
|
|
|
|
serviceProcessorNetworkStack NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, ipAddress1, ipAddress2, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A service processor network stack has changed."
|
|
::= { serviceProcessor 5 }
|
|
|
|
serviceProcessorRedundancy NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A service processor detected a redundancy."
|
|
::= { serviceProcessor 6 }
|
|
|
|
serviceProcessorRemoteLogin NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A remove login was made into the service processor."
|
|
::= { serviceProcessor 7 }
|
|
|
|
serviceProcessorRemoved NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A service processor has been removed."
|
|
::= { serviceProcessor 8 }
|
|
|
|
serviceProcessorRestart NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A service processor has been restarted."
|
|
::= { serviceProcessor 9 }
|
|
|
|
serviceProcessorTest NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A service processor test was issued."
|
|
::= { serviceProcessor 10 }
|
|
|
|
smpExpansionModule OBJECT IDENTIFIER ::= { component 16 }
|
|
|
|
smpExpansionModuleDisabled NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An SMP expansion module has been disabled."
|
|
::= { smpExpansionModule 1 }
|
|
|
|
usb OBJECT IDENTIFIER ::= { component 17 }
|
|
|
|
usbInserted NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A USB device has been inserted."
|
|
::= { usb 1 }
|
|
|
|
usbOwner NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A USB device owner has changed."
|
|
::= { usb 2 }
|
|
|
|
usbRemoved NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A USB device has been removed."
|
|
::= { usb 3 }
|
|
|
|
vrm OBJECT IDENTIFIER ::= { component 18 }
|
|
|
|
vrmFailed NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VRM has failed."
|
|
::= { vrm 1 }
|
|
|
|
critical OBJECT IDENTIFIER ::= { mpaFamily 3 }
|
|
|
|
hardDiskDrive NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A hard disk drive is in critical state."
|
|
::= { critical 1 }
|
|
|
|
multipleFanFailure NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Multiple fans have failed."
|
|
::= { critical 2 }
|
|
|
|
powerFailure OBJECT IDENTIFIER ::= { critical 3 }
|
|
|
|
powerFailureEpow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
unitNumber, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"There was a critical power failure as a result of an EPOW."
|
|
::= { powerFailure 1 }
|
|
|
|
powerFailureFailed NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
unitNumber, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"There was a critical power failure as a result of something failing."
|
|
::= { powerFailure 2 }
|
|
|
|
powerFailureRemoved NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
unitNumber, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"There was a critical power failure as a result of something removed."
|
|
::= { powerFailure 3 }
|
|
|
|
criticalTamper NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tampering with the system has caused a critical state."
|
|
::= { critical 4 }
|
|
|
|
criticalTemperature OBJECT IDENTIFIER ::= { critical 5 }
|
|
|
|
criticalTemperatureAmbient NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature is in a critical state."
|
|
::= { criticalTemperature 1 }
|
|
|
|
criticalTemperaturePci NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PCI temperature is in a critical state."
|
|
::= { criticalTemperature 2 }
|
|
|
|
criticalTemperaturePlanar NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The planar temperature is in a critical state."
|
|
::= { criticalTemperature 3 }
|
|
|
|
criticalVoltage OBJECT IDENTIFIER ::= { critical 6 }
|
|
|
|
criticalTwelveVolts OBJECT IDENTIFIER ::= { criticalVoltage 1 }
|
|
|
|
criticalTwelveVoltsHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 12V high has been detected."
|
|
::= { criticalTwelveVolts 1 }
|
|
|
|
criticalTwelveVoltsLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 12V low has been detected."
|
|
::= { criticalTwelveVolts 2 }
|
|
|
|
criticalTwelveVoltsFaultA NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 12V fault A has been detected."
|
|
::= { criticalVoltage 2 }
|
|
|
|
criticalTwelveVoltsFaultB NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 12V fault B has been detected."
|
|
::= { criticalVoltage 3 }
|
|
|
|
criticalTwelveVoltsFaultC NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 12V fault C has been detected."
|
|
::= { criticalVoltage 4 }
|
|
|
|
criticalTwelveVoltsFaultD NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 12V fault D has been detected."
|
|
::= { criticalVoltage 5 }
|
|
|
|
criticalOneVolt OBJECT IDENTIFIER ::= { criticalVoltage 6 }
|
|
|
|
criticalOneVoltHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 1V high has been detected."
|
|
::= { criticalOneVolt 1 }
|
|
|
|
criticalOneVoltLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 1V low has been detected."
|
|
::= { criticalOneVolt 2 }
|
|
|
|
criticalTwoVolts OBJECT IDENTIFIER ::= { criticalVoltage 7 }
|
|
|
|
criticalTwoVoltsHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 2V high has been detected."
|
|
::= { criticalTwoVolts 1 }
|
|
|
|
criticalTwoVoltsLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 2V low has been detected."
|
|
::= { criticalTwoVolts 2 }
|
|
|
|
criticalThreeVolts OBJECT IDENTIFIER ::= { criticalVoltage 8 }
|
|
|
|
criticalThreeVoltsHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 3V high has been detected."
|
|
::= { criticalThreeVolts 1 }
|
|
|
|
criticalThreeVoltsLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 3V low has been detected."
|
|
::= { criticalThreeVolts 2 }
|
|
|
|
criticalThreeVoltsPci OBJECT IDENTIFIER ::= { criticalVoltage 9 }
|
|
|
|
criticalThreeVoltsPciHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 3V high has been detected for the PCI."
|
|
::= { criticalThreeVoltsPci 1 }
|
|
|
|
criticalThreeVoltsPciLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 3V low has been detected for the PCI."
|
|
::= { criticalThreeVoltsPci 2 }
|
|
|
|
criticalThreeVoltsStandby OBJECT IDENTIFIER ::= { criticalVoltage 10 }
|
|
|
|
criticalThreeVoltsStandbyHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 3V standby high has been detected."
|
|
::= { criticalThreeVoltsStandby 1 }
|
|
|
|
criticalThreeVoltsStandbyLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 3V standby low has been detected."
|
|
::= { criticalThreeVoltsStandby 2 }
|
|
|
|
criticalFiveVolts OBJECT IDENTIFIER ::= { criticalVoltage 11 }
|
|
|
|
criticalFiveVoltsHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 5V high has been detected."
|
|
::= { criticalFiveVolts 1 }
|
|
|
|
criticalFiveVoltsLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 5V low has been detected."
|
|
::= { criticalFiveVolts 2 }
|
|
|
|
criticalFiveVoltsFault OBJECT IDENTIFIER ::= { criticalVoltage 12 }
|
|
|
|
criticalFiveVoltsFaultHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 5V fault high has been detected."
|
|
::= { criticalFiveVoltsFault 1 }
|
|
|
|
criticalFiveVoltsFaultLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 5V fault low has been detected."
|
|
::= { criticalFiveVoltsFault 2 }
|
|
|
|
criticalFiveVoltsPci OBJECT IDENTIFIER ::= { criticalVoltage 13 }
|
|
|
|
criticalFiveVoltsPciHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 5V high has been detected for the PCI."
|
|
::= { criticalFiveVoltsPci 1 }
|
|
|
|
criticalFiveVoltsPciLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 5V low has been detected for the PCI."
|
|
::= { criticalFiveVoltsPci 2 }
|
|
|
|
criticalFiveVoltsStandby OBJECT IDENTIFIER ::= { criticalVoltage 14 }
|
|
|
|
criticalFiveVoltsStandbyHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 5V standby high has been detected."
|
|
::= { criticalFiveVoltsStandby 1 }
|
|
|
|
criticalFiveVoltsStandbyLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of 5V standby low has been detected."
|
|
::= { criticalFiveVoltsStandby 2 }
|
|
|
|
criticalNTwelveVolts OBJECT IDENTIFIER ::= { criticalVoltage 15 }
|
|
|
|
criticalNTwelveVoltsHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of negative 12V high has been detected."
|
|
::= { criticalNTwelveVolts 1 }
|
|
|
|
criticalNTwelveVoltsLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical state of negative 12V low has been detected."
|
|
::= { criticalNTwelveVolts 2 }
|
|
|
|
voltageRegulatorModuleFailure NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The voltage regulator module has failed."
|
|
::= { critical 7 }
|
|
|
|
deployment OBJECT IDENTIFIER ::= { mpaFamily 4 }
|
|
|
|
deploymentBoot NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Deployment has generated a boot event."
|
|
::= { deployment 1 }
|
|
|
|
deploymentLoader NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Deployment has generated a loader event."
|
|
::= { deployment 2 }
|
|
|
|
deploymentOs NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Deployment has generated an operating system event."
|
|
::= { deployment 3 }
|
|
|
|
deploymentPost NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Deployment has generated a POST event."
|
|
::= { deployment 4 }
|
|
|
|
environmental OBJECT IDENTIFIER ::= { mpaFamily 5 }
|
|
|
|
environmentalTemperature NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, side, sourceUniversalUniqueId, temperatureSensor,
|
|
unitNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The environmental temperature has changed."
|
|
::= { environmental 1 }
|
|
|
|
environmentalVoltage NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
componentId, firmwareCode, senderUniversalUniqueId, side, sourceUniversalUniqueId, threshold,
|
|
voltageSensor }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The environmental voltage has changed."
|
|
::= { environmental 2 }
|
|
|
|
nonCritical OBJECT IDENTIFIER ::= { mpaFamily 6 }
|
|
|
|
nonCriticalFan OBJECT IDENTIFIER ::= { nonCritical 1 }
|
|
|
|
nonCriticalFanRemoved NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A fan has been removed."
|
|
::= { nonCriticalFan 1 }
|
|
|
|
redundantPower NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is now running on redundant power."
|
|
::= { nonCritical 2 }
|
|
|
|
singleFanFailure NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
unitNumber, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A single fan has failed."
|
|
::= { nonCritical 3 }
|
|
|
|
nonCriticalTemperature OBJECT IDENTIFIER ::= { nonCritical 4 }
|
|
|
|
nonCriticalTemperatureAmbient NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature is in a non critical state."
|
|
::= { nonCriticalTemperature 1 }
|
|
|
|
nonCriticalTemperaturePci NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PCI temperature is in a non critical state."
|
|
::= { nonCriticalTemperature 2 }
|
|
|
|
nonCriticalTemperaturePlanar NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The planar temperature is in a non critical state."
|
|
::= { nonCriticalTemperature 3 }
|
|
|
|
nonCriticalVoltage OBJECT IDENTIFIER ::= { nonCritical 5 }
|
|
|
|
nonCriticalTwelveVolts OBJECT IDENTIFIER ::= { nonCriticalVoltage 1 }
|
|
|
|
nonCriticalTwelveVoltsHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of 12V high has been detected."
|
|
::= { nonCriticalTwelveVolts 1 }
|
|
|
|
nonCriticalTwelveVoltsLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of 12V low has been detected."
|
|
::= { nonCriticalTwelveVolts 2 }
|
|
|
|
nonCriticalOneVolt OBJECT IDENTIFIER ::= { nonCriticalVoltage 2 }
|
|
|
|
nonCriticalOneVoltHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of 1V high has been detected."
|
|
::= { nonCriticalOneVolt 1 }
|
|
|
|
nonCriticalOneVoltLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of 1V low has been detected."
|
|
::= { nonCriticalOneVolt 2 }
|
|
|
|
nonCriticalTwoVolts OBJECT IDENTIFIER ::= { nonCriticalVoltage 3 }
|
|
|
|
nonCriticalTwoVoltsHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of 2V high has been detected."
|
|
::= { nonCriticalTwoVolts 1 }
|
|
|
|
nonCriticalTwoVoltsLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of 2V low has been detected."
|
|
::= { nonCriticalTwoVolts 2 }
|
|
|
|
nonCriticalThreeVolts OBJECT IDENTIFIER ::= { nonCriticalVoltage 4 }
|
|
|
|
nonCriticalThreeVoltsHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of 3V high has been detected."
|
|
::= { nonCriticalThreeVolts 1 }
|
|
|
|
nonCriticalThreeVoltsLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of 3V low has been detected."
|
|
::= { nonCriticalThreeVolts 2 }
|
|
|
|
nonCriticalThreeVoltsPci OBJECT IDENTIFIER ::= { nonCriticalVoltage 5 }
|
|
|
|
nonCriticalThreeVoltsPciHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of 3V high has been detected for the PCI."
|
|
::= { nonCriticalThreeVoltsPci 1 }
|
|
|
|
nonCriticalThreeVoltsPciLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of 3V low has been detected for the PCI."
|
|
::= { nonCriticalThreeVoltsPci 2 }
|
|
|
|
nonCriticalThreeVoltsStandby OBJECT IDENTIFIER ::= { nonCriticalVoltage 6 }
|
|
|
|
nonCriticalThreeVoltsStandbyHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of 3V standby high has been detected."
|
|
::= { nonCriticalThreeVoltsStandby 1 }
|
|
|
|
nonCriticalThreeVoltsStandbyLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of 3V standby low has been detected."
|
|
::= { nonCriticalThreeVoltsStandby 2 }
|
|
|
|
nonCriticalFiveVolts OBJECT IDENTIFIER ::= { nonCriticalVoltage 7 }
|
|
|
|
nonCriticalFiveVoltsHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of 5V high has been detected."
|
|
::= { nonCriticalFiveVolts 1 }
|
|
|
|
nonCriticalFiveVoltsLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of 5V low has been detected."
|
|
::= { nonCriticalFiveVolts 2 }
|
|
|
|
nonCriticalFiveVoltsPci OBJECT IDENTIFIER ::= { nonCriticalVoltage 8 }
|
|
|
|
nonCriticalFiveVoltsPciHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of 5V high has been detected for the PCI."
|
|
::= { nonCriticalFiveVoltsPci 1 }
|
|
|
|
nonCriticalFiveVoltsPciLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of 5V low has been detected for the PCI."
|
|
::= { nonCriticalFiveVoltsPci 2 }
|
|
|
|
nonCriticalFiveVoltsStandby OBJECT IDENTIFIER ::= { nonCriticalVoltage 9 }
|
|
|
|
nonCriticalFiveVoltsStandbyHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of 5V standby high has been detected."
|
|
::= { nonCriticalFiveVoltsStandby 1 }
|
|
|
|
nonCriticalFiveVoltsStandbyLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of 5V standby low has been detected."
|
|
::= { nonCriticalFiveVoltsStandby 2 }
|
|
|
|
nonCriticalNTwelveVolts OBJECT IDENTIFIER ::= { nonCriticalVoltage 10 }
|
|
|
|
nonCriticalNTwelveVoltsHigh NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of negative 12V high has been detected."
|
|
::= { nonCriticalNTwelveVolts 1 }
|
|
|
|
nonCriticalNTwelveVoltsLow NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
side, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-critical state of negative 12V low has been detected."
|
|
::= { nonCriticalNTwelveVolts 2 }
|
|
|
|
platform OBJECT IDENTIFIER ::= { mpaFamily 7 }
|
|
|
|
scalableNode OBJECT IDENTIFIER ::= { platform 1 }
|
|
|
|
scalableNodeMode OBJECT IDENTIFIER ::= { scalableNode 1 }
|
|
|
|
scalableNodeModeNullOrUnknown NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The scalable node is in a null or unknown mode."
|
|
::= { scalableNodeMode 1 }
|
|
|
|
scalableNodeModePrimary NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The scalable node is in primary mode."
|
|
::= { scalableNodeMode 2 }
|
|
|
|
scalableNodeModeSecondary NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The scalable node is in secondary mode."
|
|
::= { scalableNodeMode 3 }
|
|
|
|
scalableNodeModeStandalone NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The scalable node is now in standalone mode."
|
|
::= { scalableNodeMode 4 }
|
|
|
|
scalableNodeStandalone OBJECT IDENTIFIER ::= { scalableNode 2 }
|
|
|
|
standaloneMode OBJECT IDENTIFIER ::= { scalableNodeStandalone 1 }
|
|
|
|
primary NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The scalable node is now in standalone primary mode."
|
|
::= { standaloneMode 1 }
|
|
|
|
reset OBJECT IDENTIFIER ::= { standaloneMode 2 }
|
|
|
|
resetPrimary NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The scalable node is now in standalone primary reset mode."
|
|
::= { reset 1 }
|
|
|
|
resetSecondary NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The scalable node is now in standalone primary secondary mode."
|
|
::= { reset 2 }
|
|
|
|
secondary NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The scalable node is now in standalone secondary mode."
|
|
::= { standaloneMode 3 }
|
|
|
|
scalablePartition OBJECT IDENTIFIER ::= { platform 2 }
|
|
|
|
scalablePartitionAlert NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
alertCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The scalabel partition has generated an alert."
|
|
::= { scalablePartition 1 }
|
|
|
|
scalablePartitionState OBJECT IDENTIFIER ::= { scalablePartition 2 }
|
|
|
|
scalablePartitionNullOrUnknown NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The scalable partition state is 'null or unknown'."
|
|
::= { scalablePartitionState 1 }
|
|
|
|
scalablePartitionPoweredOff NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The scalable partition state is 'powered off'."
|
|
::= { scalablePartitionState 2 }
|
|
|
|
scalablePartitionPoweringOn NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The scalable partition state is 'powering on'."
|
|
::= { scalablePartitionState 3 }
|
|
|
|
scalablePartitionResetting NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The scalable partition state is 'resetting'."
|
|
::= { scalablePartitionState 4 }
|
|
|
|
scalablePartitionShuttingDown NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The scalable partition state is 'shutting down'."
|
|
::= { scalablePartitionState 5 }
|
|
|
|
system OBJECT IDENTIFIER ::= { mpaFamily 8 }
|
|
|
|
bootFailure NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system indicated a boot failure."
|
|
::= { system 1 }
|
|
|
|
fuelGauge OBJECT IDENTIFIER ::= { system 2 }
|
|
|
|
fuelGaugeLowFuel NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The fuel gauge indicates low fuel."
|
|
::= { fuelGauge 1 }
|
|
|
|
fuelGaugeNotRedundant NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The fuel gauge indicates not redundant."
|
|
::= { fuelGauge 2 }
|
|
|
|
fuelGaugeOverCurrent NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The fuel gauge indicates over current."
|
|
::= { fuelGauge 3 }
|
|
|
|
systemLoaderTimeout NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system loader has timed out."
|
|
::= { system 3 }
|
|
|
|
systemOsTimeout NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operating system has timed out."
|
|
::= { system 4 }
|
|
|
|
systemPfa OBJECT IDENTIFIER ::= { system 5 }
|
|
|
|
fanSystemPfa NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
unitNumber, universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The fan system has generated a PFA."
|
|
::= { systemPfa 1 }
|
|
|
|
systemPostTimeout NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The POST has timed out."
|
|
::= { system 6 }
|
|
|
|
systemPowerOff NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sytsem has powered off."
|
|
::= { system 7 }
|
|
|
|
systemPowerOn NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sytsem has powered on."
|
|
::= { system 8 }
|
|
|
|
systemRedundantPower NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is running on redundant power."
|
|
::= { system 9 }
|
|
|
|
systemTamper NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
universalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system has been tampered with."
|
|
::= { system 10 }
|
|
|
|
unknown NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is in an unknown state."
|
|
::= { mpaFamily 9 }
|
|
|
|
--
|
|
-- PET/ASF traps
|
|
--
|
|
|
|
petFamily OBJECT IDENTIFIER ::= { directorTraps 5 }
|
|
|
|
petFamilyEventDetails OBJECT IDENTIFIER ::= { petFamily 1 }
|
|
|
|
allVariableBindings OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All of the variable bindings for this PET trap."
|
|
::= { petFamilyEventDetails 1 }
|
|
|
|
entity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entity of this PET event."
|
|
::= { petFamilyEventDetails 2 }
|
|
|
|
entityInstance OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entity instance of this PET event."
|
|
::= { petFamilyEventDetails 3 }
|
|
|
|
petEventData OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The event data of this PET event."
|
|
::= { petFamilyEventDetails 4 }
|
|
|
|
petEventSeverity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The severity of this PET event."
|
|
::= { petFamilyEventDetails 5 }
|
|
|
|
petEventSourceType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source type of this PET event."
|
|
::= { petFamilyEventDetails 6 }
|
|
|
|
petEventType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of the PET event."
|
|
::= { petFamilyEventDetails 7 }
|
|
|
|
guid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The GUID for this PET event."
|
|
::= { petFamilyEventDetails 8 }
|
|
|
|
languageCode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The language code for this PET event."
|
|
::= { petFamilyEventDetails 9 }
|
|
|
|
localTimeStamp OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The local time stamp of this PET event."
|
|
::= { petFamilyEventDetails 10 }
|
|
|
|
manufacturerId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer ID for the source of the PET event."
|
|
::= { petFamilyEventDetails 11 }
|
|
|
|
oemCustomField OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value for the OEM customer field of this PET event."
|
|
::= { petFamilyEventDetails 12 }
|
|
|
|
offset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The offset for this PET event."
|
|
::= { petFamilyEventDetails 13 }
|
|
|
|
sensorDevice OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor device for this PET event."
|
|
::= { petFamilyEventDetails 14 }
|
|
|
|
sensorNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor number for this PET event."
|
|
::= { petFamilyEventDetails 15 }
|
|
|
|
sensorType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor type for this PET event."
|
|
::= { petFamilyEventDetails 16 }
|
|
|
|
sequenceId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sequence ID for this PET event."
|
|
::= { petFamilyEventDetails 17 }
|
|
|
|
systemId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system ID for this PET event."
|
|
::= { petFamilyEventDetails 18 }
|
|
|
|
trapSourceType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trap source type for this PET event."
|
|
::= { petFamilyEventDetails 19 }
|
|
|
|
utcOffset OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UTC offset for this PET event."
|
|
::= { petFamilyEventDetails 20 }
|
|
|
|
petEnvironmental OBJECT IDENTIFIER ::= { petFamily 2 }
|
|
|
|
petEnvironmentalSensor OBJECT IDENTIFIER ::= { petEnvironmental 1 }
|
|
|
|
sensorCaseIntrusion NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
|
|
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
|
|
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A sensor has detected a case intrusion."
|
|
::= { petEnvironmentalSensor 1 }
|
|
|
|
sensorCurrent NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
|
|
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
|
|
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A sensor has detected a current change."
|
|
::= { petEnvironmentalSensor 2 }
|
|
|
|
sensorFan NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
|
|
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
|
|
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A sensor has detected a fan change."
|
|
::= { petEnvironmentalSensor 3 }
|
|
|
|
sensorPowerSupply NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
|
|
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
|
|
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A sensor has detected a power supply change."
|
|
::= { petEnvironmentalSensor 4 }
|
|
|
|
sensorTemperature NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
|
|
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
|
|
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A sensor has detected a temperature change."
|
|
::= { petEnvironmentalSensor 5 }
|
|
|
|
sensorVoltage NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
|
|
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
|
|
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A sensor has detected a voltage change."
|
|
::= { petEnvironmentalSensor 6 }
|
|
|
|
firmware OBJECT IDENTIFIER ::= { petFamily 3 }
|
|
|
|
bios OBJECT IDENTIFIER ::= { firmware 1 }
|
|
|
|
progress NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
|
|
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
|
|
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The progress of the BIOS has changed."
|
|
::= { bios 1 }
|
|
|
|
hardware OBJECT IDENTIFIER ::= { petFamily 4 }
|
|
|
|
cableInterconnect NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
|
|
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
|
|
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The cable/interconnect hardware has generated an event."
|
|
::= { hardware 1 }
|
|
|
|
drivebay NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
|
|
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
|
|
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The monitor drivebay hardware has generated an event."
|
|
::= { hardware 2 }
|
|
|
|
moduleBoard NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
|
|
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
|
|
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The monitor module/board hardware has generated an event."
|
|
::= { hardware 3 }
|
|
|
|
monitorAsicIc NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
|
|
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
|
|
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The monitor ASIC/IC hardware has generated an event."
|
|
::= { hardware 4 }
|
|
|
|
network NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
|
|
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
|
|
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The network hardware has generated an event."
|
|
::= { hardware 5 }
|
|
|
|
watchdog1 NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
|
|
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
|
|
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hardware has generated a watchdog 1 event."
|
|
::= { hardware 6 }
|
|
|
|
watchdog2 NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
|
|
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
|
|
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hardware has generated a watchdog 2 event."
|
|
::= { hardware 7 }
|
|
|
|
petFamilySystem OBJECT IDENTIFIER ::= { petFamily 5 }
|
|
|
|
petFamilySystemOs OBJECT IDENTIFIER ::= { petFamilySystem 1 }
|
|
|
|
petFamilySystemOsBoot NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
|
|
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
|
|
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operating system on the host has booted."
|
|
::= { petFamilySystemOs 1 }
|
|
|
|
petFamilySystemOsOperation OBJECT IDENTIFIER ::= { petFamilySystemOs 2 }
|
|
|
|
heartbeat NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory,
|
|
allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType,
|
|
petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset,
|
|
sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operating system has generated a heartbeat event."
|
|
::= { petFamilySystemOsOperation 1 }
|
|
|
|
--
|
|
-- Storage traps
|
|
--
|
|
|
|
storageFamily OBJECT IDENTIFIER ::= { directorTraps 6 }
|
|
|
|
serveRaidController OBJECT IDENTIFIER ::= { storageFamily 1 }
|
|
|
|
physicalDrive OBJECT IDENTIFIER ::= { serveRaidController 1 }
|
|
|
|
vendorUnsupported NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vendor for this physical drive is unsupported."
|
|
::= { physicalDrive 1 }
|
|
|
|
state OBJECT IDENTIFIER ::= { serveRaidController 2 }
|
|
|
|
notFound NOTIFICATION-TYPE
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No controllers were found in this system."
|
|
::= { state 1 }
|
|
|
|
--
|
|
-- The trap description objects
|
|
--
|
|
|
|
trapType OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of the event."
|
|
::= { description 1 }
|
|
|
|
trapSeverity OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The severity of the event."
|
|
::= { description 2 }
|
|
|
|
trapSenderName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system name from which the event was sent."
|
|
::= { description 3 }
|
|
|
|
trapManagedObjectName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system name for which the event was generated."
|
|
::= { description 4 }
|
|
|
|
trapText OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Text associated with the event."
|
|
::= { description 5 }
|
|
|
|
trapCategory OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The category of the event."
|
|
::= { description 6 }
|
|
|
|
--
|
|
-- Trap detail types
|
|
--
|
|
-- NOTE:
|
|
--
|
|
-- When viewing a trap holding an event detail type, the number following these
|
|
-- OIDs refer to different values of this type. They increment according to
|
|
-- each trap, ergo, you should never see a { char 2 } without a { char 1 }.
|
|
--
|
|
|
|
char OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Eight bit unsigned event detail."
|
|
::= { details 1 }
|
|
|
|
short OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sixteen bit signed event detail."
|
|
::= { details 2 }
|
|
|
|
int OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Thirty-two bit signed event detail."
|
|
::= { details 3 }
|
|
|
|
long OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sixty-four bit signed event detail."
|
|
::= { details 4 }
|
|
|
|
boolean OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Thirty-two bit unsigned event detail."
|
|
::= { details 5 }
|
|
|
|
float OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Thirty-two bit decimal pointed event detail."
|
|
::= { details 6 }
|
|
|
|
double OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sixty-four bit decimal pointed event detail."
|
|
::= { details 7 }
|
|
|
|
octet OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string of bytes holding an event detail."
|
|
::= { details 8 }
|
|
|
|
string OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string of unicode chars (normal text) holding
|
|
an event detail."
|
|
::= { details 9 }
|
|
|
|
dateTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Date and time since 1/1970 as an event
|
|
detail."
|
|
::= { details 10 }
|
|
|
|
uniChar OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unicode char holding an event detail."
|
|
::= { details 11 }
|
|
|
|
byte OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One byte holding an event detail."
|
|
::= { details 12 }
|
|
|
|
directorTrapsConformance OBJECT IDENTIFIER ::= { directorTraps 100 }
|
|
|
|
directorTrapsGroups OBJECT IDENTIFIER ::= { directorTrapsConformance 1 }
|
|
directorTrapsCompliances OBJECT IDENTIFIER ::= { directorTrapsConformance 2 }
|
|
|
|
directorTrapsCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for this module."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { directorTrapsGroup, directorNotificationsGroup }
|
|
::= { directorTrapsCompliances 1 }
|
|
|
|
directorTrapsGroup OBJECT-GROUP
|
|
OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText,
|
|
trapCategory, char, short, int, long, boolean, float, octet, double, string, dateTime,
|
|
uniChar, byte, actualValue, duration, monitorResource, thresholdName, thresholdValue,
|
|
userID, address, userName, userDescription, userLocale, category, categoryString,
|
|
computerName, data, eventLogCode, eventLogIdentifier, eventLogType, insertionStrings,
|
|
logFile, message, recordNumber, sourceName, type, user, acceptPause, acceptStop,
|
|
caption, checkPoint, creationClassName, serviceDescription, desktopInteract,
|
|
displayName, errorControl, exitCode, name, pathName, processId, serviceSpecificExitCode,
|
|
serviceType, startMode, startName, started, serviceState, status,
|
|
systemCreationClassName, systemName, tagId, waitHint, hive, rootPath, securityDescriptor,
|
|
timeCreated, alertCode, busId, componentId, firmwareCode, ipAddress1, ipAddress2, issue,
|
|
powerDomain, reason, scsiId, side, newState, temperatureSensor, threshold,
|
|
universalUniqueId, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber,
|
|
voltageSensor, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity,
|
|
petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId,
|
|
oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId,
|
|
trapSourceType, utcOffset }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The objects group for objects defined in this module."
|
|
::= { directorTrapsGroups 1 }
|
|
|
|
directorNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { generalEvent, online, offline, create, change, destroy, processMonitor,
|
|
cpuUtilization, processCount, driveSpaceUsed, driveSpaceUsedPercent,
|
|
driveSpaceRemaining, driveWorkload, lockedMemory, memoryUsage,
|
|
totalPrivilegedTimePercent, fileReadOperationsPerSec, udpPacketsSentPerSec,
|
|
udpPacketsReceivedPerSec, ipPacketsSentPerSec, ipPacketsReceivedPerSec,
|
|
ipErrorPacketsReceivedPerSec, tcpConnections, action, badPassword,
|
|
badUserID, disabledUserID, downlevelConsole, expiredPassword, tooManyActiveIDs,
|
|
tooManyActiveLogons, uplevelConsole, logoff, logon, applicationLog, securityLog,
|
|
systemLog, startedService, stoppedService, softwareTreeChanged, systemTreeChanged,
|
|
codEnabled, bladeServerCommunication, bladeServerInserted, bladeServerRemoved,
|
|
busCommunication, chassisConfiguration, chassisFailed, dasdFailed, dasdInserted,
|
|
dasdRemoved, memoryFailed, componentFanFailed, componentFanInserted, componentFanPfa,
|
|
componentFanRemoved, hardwareCrashDumpAborted, hardwareCrashDumpCompleted,
|
|
hardwareCrashDumpInitiated, ioModuleConfiguration, ioModuleFailed, ioModuleInserted,
|
|
ioModulePost, ioModulePowerOn, ioModulePowerOff, ioModuleRedundancy, ioModuleRemoved,
|
|
kvmOwner, osImageCrashDumpAborted, osImageCrashDumpCompleted, osImageCrashDumpInitiated,
|
|
componentPfa, powerSubsystemLowFuel, powerSubsystemOverCurrent, powerSubsystemOverPower,
|
|
powerSubsystemRedundancy, powerSupplyFailed, powerSupplyInserted, powerSupplyRemoved,
|
|
serverPowerOff, serverPowerOn, serverPowerState, serviceProcessorActive,
|
|
serviceProcessorConfiguration, serviceProcessorInserted, serviceProcessorLog,
|
|
serviceProcessorNetworkStack, serviceProcessorRedundancy, serviceProcessorRemoteLogin,
|
|
serviceProcessorRemoved, serviceProcessorRestart, serviceProcessorTest,
|
|
smpExpansionModuleDisabled, usbInserted, usbOwner, usbRemoved, vrmFailed, hardDiskDrive,
|
|
multipleFanFailure, powerFailureEpow, powerFailureFailed, powerFailureRemoved,
|
|
criticalTamper, criticalTemperatureAmbient, criticalTemperaturePci,
|
|
criticalTemperaturePlanar, criticalTwelveVoltsHigh, criticalTwelveVoltsLow,
|
|
criticalTwelveVoltsFaultA, criticalTwelveVoltsFaultB, criticalTwelveVoltsFaultC,
|
|
criticalTwelveVoltsFaultD, criticalOneVoltHigh, criticalOneVoltLow,
|
|
criticalTwoVoltsHigh, criticalTwoVoltsLow, criticalThreeVoltsHigh,
|
|
criticalThreeVoltsLow, criticalThreeVoltsPciHigh, criticalThreeVoltsPciLow,
|
|
criticalThreeVoltsStandbyHigh, criticalThreeVoltsStandbyLow, criticalFiveVoltsHigh,
|
|
criticalFiveVoltsLow, criticalFiveVoltsFaultHigh, criticalFiveVoltsFaultLow,
|
|
criticalFiveVoltsPciHigh, criticalFiveVoltsPciLow, criticalFiveVoltsStandbyHigh,
|
|
criticalFiveVoltsStandbyLow, criticalNTwelveVoltsHigh, criticalNTwelveVoltsLow,
|
|
voltageRegulatorModuleFailure, deploymentBoot, deploymentLoader, deploymentOs,
|
|
deploymentPost, environmentalTemperature, environmentalVoltage, nonCriticalFanRemoved,
|
|
redundantPower, singleFanFailure, nonCriticalTemperatureAmbient, nonCriticalTemperaturePci,
|
|
nonCriticalTemperaturePlanar, nonCriticalTwelveVoltsHigh, nonCriticalTwelveVoltsLow,
|
|
nonCriticalOneVoltHigh, nonCriticalOneVoltLow, nonCriticalTwoVoltsHigh, nonCriticalTwoVoltsLow,
|
|
nonCriticalThreeVoltsHigh, nonCriticalThreeVoltsLow, nonCriticalThreeVoltsPciHigh,
|
|
nonCriticalThreeVoltsPciLow, nonCriticalThreeVoltsStandbyHigh, nonCriticalThreeVoltsStandbyLow,
|
|
nonCriticalFiveVoltsHigh, nonCriticalFiveVoltsLow, nonCriticalFiveVoltsPciHigh,
|
|
nonCriticalFiveVoltsPciLow, nonCriticalFiveVoltsStandbyHigh, nonCriticalFiveVoltsStandbyLow,
|
|
nonCriticalNTwelveVoltsHigh, nonCriticalNTwelveVoltsLow, scalableNodeModeNullOrUnknown,
|
|
scalableNodeModePrimary, scalableNodeModeSecondary, scalableNodeModeStandalone, primary, resetPrimary,
|
|
resetSecondary, secondary, scalablePartitionAlert, scalablePartitionNullOrUnknown,
|
|
scalablePartitionPoweredOff, scalablePartitionPoweringOn, scalablePartitionResetting,
|
|
scalablePartitionShuttingDown, bootFailure, fuelGaugeLowFuel, fuelGaugeNotRedundant, fuelGaugeOverCurrent,
|
|
systemLoaderTimeout, systemOsTimeout, fanSystemPfa, systemPostTimeout, systemPowerOff,
|
|
systemPowerOn, systemRedundantPower, systemTamper, unknown, sensorCaseIntrusion,
|
|
sensorCurrent, sensorFan, sensorPowerSupply, sensorTemperature, sensorVoltage,
|
|
progress, cableInterconnect, drivebay, moduleBoard, monitorAsicIc, network, watchdog1,
|
|
watchdog2, petFamilySystemOsBoot, heartbeat, vendorUnsupported, notFound }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The notification group for notifications defined in this module."
|
|
::= { directorTrapsGroups 2 }
|
|
|
|
|
|
END
|