mibs/MIBS/ibm/IBM-INTERFACE-MIB

292 lines
8.7 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- MIB created 10/11/99 20:28:35, by
-- SMIC (the next generation) version 1.6.29, November 22, 1994.
IBM-INTERFACE-MIB DEFINITIONS ::= BEGIN
-- From file: "ibminterface.mi2"
-- Compile options "G A T M"
IMPORTS
Counter32, IpAddress
FROM SNMPv2-SMI-v1
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM SNMPv2-TC-v1
enterprises
FROM RFC1155-SMI
ifIndex
FROM RFC1213-MIB;
ibmIROCroutinginterface OBJECT IDENTIFIER ::= { enterprises ibm(2) ibmProd(6) ibmIROC(119) ibmIROCrouting(4) 17 }
-- MODULE-IDENTITY
-- LastUpdated
-- 9902171200Z
-- OrgName
-- IBM
-- ContactInfo
-- Randy Worzella
-- IBM Corporation
-- 800 Park Offices Drive
-- FBWA/664
-- P.O. Box 12195
-- Research Triangle Park, NC 27709, USA
-- Tel: 1 919 254 2202
-- E-mail: worzella@us.ibm.com
-- Descr
-- This MIB module contains enterprise specific definitions for
-- generic interface management.
ibminterfaceClearTable OBJECT-TYPE
SYNTAX SEQUENCE OF IbminterfaceClearEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table allowing interface counters to be cleared."
::= { ibmIROCroutinginterface 1 }
ibminterfaceClearEntry OBJECT-TYPE
SYNTAX IbminterfaceClearEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entry identifying a particular interface whose counters
are to be cleared."
INDEX { ifIndex }
::= { ibminterfaceClearTable 1 }
IbminterfaceClearEntry ::= SEQUENCE {
ibminterfaceClearInOctets INTEGER,
ibminterfaceClearInUcastPkts INTEGER,
ibminterfaceClearInMulticastPkts INTEGER,
ibminterfaceClearInErrors INTEGER,
ibminterfaceClearInAll INTEGER,
ibminterfaceClearOutOctets INTEGER,
ibminterfaceClearOutUcastPkts INTEGER,
ibminterfaceClearOutMulticastPkts INTEGER,
ibminterfaceClearOutErrors INTEGER,
ibminterfaceClearOutAll INTEGER,
ibminterfaceClearMaintTest INTEGER,
ibminterfaceClearDeviceSpecific INTEGER,
ibminterfaceClearAll INTEGER
}
ibminterfaceClearInOctets OBJECT-TYPE
SYNTAX INTEGER {
noaction(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When SET to a value of clear(1), the counter of bytes
received over this interface is reset.
When READ, this object always returns a value of noaction(0),
since this object is intended as a trigger, rather than
providing information."
::= { ibminterfaceClearEntry 1 }
ibminterfaceClearInUcastPkts OBJECT-TYPE
SYNTAX INTEGER {
noaction(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When SET to a value of clear(1), the counter of unicast
packets received over this interface is reset.
When READ, this object always returns a value of noaction(0),
since this object is intended as a trigger, rather than
providing information."
::= { ibminterfaceClearEntry 2 }
ibminterfaceClearInMulticastPkts OBJECT-TYPE
SYNTAX INTEGER {
noaction(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When SET to a value of clear(1), the counter of multicast
packets received over this interface is reset.
When READ, this object always returns a value of noaction(0),
since this object is intended as a trigger, rather than
providing information."
::= { ibminterfaceClearEntry 3 }
ibminterfaceClearInErrors OBJECT-TYPE
SYNTAX INTEGER {
noaction(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When SET to a value of clear(1), the counters for all
types of input errors are reset.
When READ, this object always returns a value of noaction(0),
since this object is intended as a trigger, rather than
providing information."
::= { ibminterfaceClearEntry 4 }
ibminterfaceClearInAll OBJECT-TYPE
SYNTAX INTEGER {
noaction(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When SET to a value of clear(1), the counters for all
input counters (byte, packet, error) are reset.
When READ, this object always returns a value of noaction(0),
since this object is intended as a trigger, rather than
providing information."
::= { ibminterfaceClearEntry 5 }
ibminterfaceClearOutOctets OBJECT-TYPE
SYNTAX INTEGER {
noaction(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When SET to a value of clear(1), the counter of bytes
sent over this interface is reset.
When READ, this object always returns a value of noaction(0),
since this object is intended as a trigger, rather than
providing information."
::= { ibminterfaceClearEntry 6 }
ibminterfaceClearOutUcastPkts OBJECT-TYPE
SYNTAX INTEGER {
noaction(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When SET to a value of clear(1), the counter of unicast
packets sent over this interface is reset.
When READ, this object always returns a value of noaction(0),
since this object is intended as a trigger, rather than
providing information."
::= { ibminterfaceClearEntry 7 }
ibminterfaceClearOutMulticastPkts OBJECT-TYPE
SYNTAX INTEGER {
noaction(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When SET to a value of clear(1), the counter of multicast
packets sent over this interface is reset.
When READ, this object always returns a value of noaction(0),
since this object is intended as a trigger, rather than
providing information."
::= { ibminterfaceClearEntry 8 }
ibminterfaceClearOutErrors OBJECT-TYPE
SYNTAX INTEGER {
noaction(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When SET to a value of clear(1), the counters for all
types of output errors are reset.
When READ, this object always returns a value of noaction(0),
since this object is intended as a trigger, rather than
providing information."
::= { ibminterfaceClearEntry 9 }
ibminterfaceClearOutAll OBJECT-TYPE
SYNTAX INTEGER {
noaction(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When SET to a value of clear(1), the counters for all
output counters (byte, packet, error) are reset.
When READ, this object always returns a value of noaction(0),
since this object is intended as a trigger, rather than
providing information."
::= { ibminterfaceClearEntry 10 }
ibminterfaceClearMaintTest OBJECT-TYPE
SYNTAX INTEGER {
noaction(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When SET to a value of clear(1), the counters for
self test pass, self test fail and maintenance
fail are reset.
When READ, this object always returns a value of noaction(0),
since this object is intended as a trigger, rather than
providing information."
::= { ibminterfaceClearEntry 11 }
ibminterfaceClearDeviceSpecific OBJECT-TYPE
SYNTAX INTEGER {
noaction(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When SET to a value of clear(1), all the device specific
counters are reset. For example, for an Ethernet
interface, all the counters provided in the
dot3StatsTable are reset.
When READ, this object always returns a value of noaction(0),
since this object is intended as a trigger, rather than
providing information."
::= { ibminterfaceClearEntry 12 }
ibminterfaceClearAll OBJECT-TYPE
SYNTAX INTEGER {
noaction(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When SET to a value of clear(1), all the reset actions
performed by the MIB objects defined above are executed
at once.
This action has the same behavior as executing the
CLEAR command from the T5 console prompt (+).
When READ, this object always returns a value of noaction(0),
since this object is intended as a trigger, rather than
providing information."
::= { ibminterfaceClearEntry 13 }
END