LUM-OCM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Integer32
FROM SNMPv2-SMI
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
DisplayString, DateAndTime
FROM SNMPv2-TC
lumModules, lumOcmMIB
FROM LUM-REG
FaultStatus, MgmtNameString, SubrackNumber, SlotNumber, PortNumber,
LambdaFrequency, BoardOrInterfaceOperStatus, BoardOrInterfaceAdminStatus,
CommandString
FROM LUM-TC;
lumOcmMIBModule MODULE-IDENTITY
LAST-UPDATED
"201806150000Z" -- June 15th 2018
ORGANIZATION
"Infinera Corporation"
CONTACT-INFO
"techsupport@infinera.com"
DESCRIPTION
"The optical control interface MIB.
- General
- Monitor interfaces
Note that, every time a get operation is performed and both ports are set
to admin status up, the switch will switch to update both ports. (unless
commissioning mode) The guaranteed durability of switching is 10 million times.
That means, if you switch (perform a get operation) more than every 50 second,
product lifetime of 15 years can not be guaranteed.
"
REVISION
"201806150000Z" -- June 15th 2018
DESCRIPTION
" Changes made for release r31.0:
- Added ocmIfSpacingMode and ocmIfHighInputPower in ocmIfEntry."
REVISION
"201712150000Z" -- Dec 15th 2017
DESCRIPTION
" Changes made for release r30.0:
- Added ocmChannelReferenceTime and ocmChannelSaveReference action in ocmChannel."
REVISION
"201706150000Z" -- June 15th 2017
DESCRIPTION
"Changes made for release r29.0:
- Changed ORGANIZATION and CONTACT-INFO"
REVISION
"201601110000Z" -- Jan 11th 2016
DESCRIPTION
"Added default value notPresent for operStatus."
REVISION
"201405160000Z" -- May 16th 2014
DESCRIPTION
"Added a parameter for offset adjustment which will allow for better
regulation in the optical control loop"
REVISION
"200801160000Z" -- January 16th 2008
DESCRIPTION
"First version."
::= { lumModules 33 }
-- ----------------------------------------------------
-- Conformance area, containing groups and complicance
-- specifications.
-- ----------------------------------------------------
lumOcmConfs OBJECT IDENTIFIER ::= { lumOcmMIB 1 }
lumOcmGroups OBJECT IDENTIFIER ::= { lumOcmConfs 1 }
lumOcmCompl OBJECT IDENTIFIER ::= { lumOcmConfs 2 }
lumOcmMinimalGroups OBJECT IDENTIFIER ::= { lumOcmConfs 3 }
lumOcmMinimalCompl OBJECT IDENTIFIER ::= { lumOcmConfs 4 }
-- ----------------------------------------------------
-- Root for objects in the ocm MIB
-- ----------------------------------------------------
lumOcmMIBObjects OBJECT IDENTIFIER ::= { lumOcmMIB 2 }
-- ----------------------------------------------------
-- This MIB contains the following groups:
-- ----------------------------------------------------
ocmGeneral OBJECT IDENTIFIER ::= { lumOcmMIBObjects 1 }
ocmIfList OBJECT IDENTIFIER ::= { lumOcmMIBObjects 2 }
ocmChannelList OBJECT IDENTIFIER ::= { lumOcmMIBObjects 3 }
lumentisOcmNotifications OBJECT IDENTIFIER ::= { lumOcmMIBObjects 4 }
-- ----------------------------------------------------
-- Textual Conventions
-- ----------------------------------------------------
-- ----------------------------------------------------
-- General group
-- ----------------------------------------------------
ocmGeneralLastChangeTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time when the configuration of the MIB
was last changed.
"
::= { ocmGeneral 1 }
ocmGeneralStateLastChangeTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time when the state of the MIB was last
changed.
"
::= { ocmGeneral 2 }
ocmGeneralOcmIfTableSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Size of table
"
::= { ocmGeneral 3 }
ocmGeneralOcmChannelTableSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Size of table
"
::= { ocmGeneral 4 }
-- ----------------------------------------------------
-- Optical control interfaces
-- ----------------------------------------------------
ocmIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcmIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interface list."
::= { ocmIfList 1 }
ocmIfEntry OBJECT-TYPE
SYNTAX OcmIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the interface list.
"
INDEX { ocmIfIndex }
::= { ocmIfTable 1 }
OcmIfEntry ::=
SEQUENCE {
ocmIfIndex Unsigned32,
ocmIfName MgmtNameString,
ocmIfDescr DisplayString,
ocmIfSubrack SubrackNumber,
ocmIfSlot SlotNumber,
ocmIfRxPort PortNumber,
ocmIfInvPhysIndexOrZero Unsigned32,
ocmIfAdminStatus BoardOrInterfaceAdminStatus,
ocmIfOperStatus BoardOrInterfaceOperStatus,
ocmIfPowerThreshold Integer32,
ocmIfPowerOffset Integer32,
ocmIfMaxPowerLevel Integer32,
ocmIfMinPowerLevel Integer32,
ocmIfDeltaPower Integer32,
ocmIfConnectedBoardType INTEGER,
ocmIfUpdateLastChangeTime DateAndTime,
ocmIfConnectedSubrack SubrackNumber,
ocmIfConnectedSlot SlotNumber,
ocmIfConnectedPort PortNumber,
ocmIfActivePort PortNumber,
ocmIfControlMode INTEGER,
ocmIfReferenceTime DisplayString,
ocmIfSwitchFailure FaultStatus,
ocmIfDataSourceNotDefined FaultStatus,
ocmIfCommissioningMode FaultStatus,
ocmIfModuleFailure FaultStatus,
ocmIfConfigurationCommand CommandString,
ocmIfChangeConnectedPort CommandString,
ocmIfSaveReference CommandString,
ocmIfChangeConnectedBoardType CommandString,
ocmIfChangePowerThreshold CommandString,
ocmIfChangePowerOffset CommandString,
ocmIfPowerOffsetAdjustment Integer32,
ocmIfSpacingMode Integer32,
ocmIfHighInputPower FaultStatus }
ocmIfIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An arbitrary index assigned to each entry.
"
::= { ocmIfEntry 1 }
ocmIfName OBJECT-TYPE
SYNTAX MgmtNameString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The management name of the interface, for
example 'ocm:1:2:1', where the first number
indicates sub-rack, the second slot number and
the third is the port number.
Examples:
ocm:s:s:p - Optical channel module interface
"
::= { ocmIfEntry 2 }
ocmIfDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User configurable label.
"
DEFVAL { "" }
::= { ocmIfEntry 3 }
ocmIfSubrack OBJECT-TYPE
SYNTAX SubrackNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of the subrack where the interface
is located.
"
::= { ocmIfEntry 4 }
ocmIfSlot OBJECT-TYPE
SYNTAX SlotNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of the slot where the interface is
located.
"
::= { ocmIfEntry 5 }
ocmIfRxPort OBJECT-TYPE
SYNTAX PortNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of the port where the RX-side of
the interface is located.
"
::= { ocmIfEntry 6 }
ocmIfInvPhysIndexOrZero OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The row in the invPhysTable for this interface.
Set to 0 if not known.
"
::= { ocmIfEntry 7 }
ocmIfAdminStatus OBJECT-TYPE
SYNTAX BoardOrInterfaceAdminStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administrative state for the interface.
down - The interface should be inactive.
service - The interface is activated but alarms
are suppressed. Intended for use during service
or re-configuration. When service is concluded
adminStatus should be set to 'up' again.
up - The interface should be activated when
it becomes available. Alarms are not suppressed.
"
DEFVAL { up }
::= { ocmIfEntry 8 }
ocmIfOperStatus OBJECT-TYPE
SYNTAX BoardOrInterfaceOperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational state for the interface.
notPresent - The physical resources are not
available.
down - The interface is de-activated or the are
faults preventing it from going to the 'up'-state.
up - The interface is operational.
"
DEFVAL { notPresent }
::= { ocmIfEntry 9 }
ocmIfPowerThreshold OBJECT-TYPE
SYNTAX Integer32 (-50..100)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The threshold for power levels. If the measured
power level is below the threshold, it is regarded
as no signal.
For OCM8p:
Default -13dBm
Range -35 to 100dBm
For OCM2p:
"
DEFVAL { -24 }
::= { ocmIfEntry 12 }
ocmIfUpdateLastChangeTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time when the last measurement was done.
"
::= { ocmIfEntry 13 }
ocmIfConnectedSubrack OBJECT-TYPE
SYNTAX SubrackNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of the subrack where the connected
interface is located. (0 is not valid)
"
DEFVAL { 0 }
::= { ocmIfEntry 14 }
ocmIfConnectedSlot OBJECT-TYPE
SYNTAX SlotNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of the slot where the connected
interface is located. (not possible to set 0, 1,
19-22, oa/roadm can not be placed in those slots)
"
DEFVAL { 0 }
::= { ocmIfEntry 15 }
ocmIfConnectedPort OBJECT-TYPE
SYNTAX PortNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of the connected port.
(the tx port number).
1 or 3 for OA,
5 for 1x2ROADM/100G/50G,
9 for 1x4ROADM/100G,ROADM1x4f,
17 for 1x8ROADM/50G,
19 for ROADM1x9f,
1 for OA26C,
5 for OARAED21HG
81 for MDU40.
and 1 to 82 for other boards.
"
DEFVAL { 0 }
::= { ocmIfEntry 16 }
ocmIfActivePort OBJECT-TYPE
SYNTAX PortNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the active port.
Only valid when commissioning mode.
"
DEFVAL { 1 }
::= { ocmIfEntry 17 }
ocmIfControlMode OBJECT-TYPE
SYNTAX INTEGER {
normal (1),
commissioning (2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"What mode the ocm is in.
normal - the switch toggle every hour
and measure both ports.
commissioning - the switch is set to one active
port and measurement is made continuously on this port.
After 15 minutes it will change back to normal mode.
Note that it is not possible to get updated
values on port that is not chosen as active during
commissioning mode.
"
DEFVAL { normal }
::= { ocmIfEntry 18 }
ocmIfReferenceTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time where reference values were saved.
"
::= { ocmIfEntry 21 }
ocmIfSwitchFailure OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Switch failure.
A: The switch is stuck and it is not possible
to change port. It is not sure if it the values
comes from the expected port.
D: The switch works as expected.
"
::= { ocmIfEntry 22 }
ocmIfDataSourceNotDefined OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Data source not defined,
A: No connected slot, connected subrack
nor connected port is defined.
D: Connected slot, connected subrack and
connected port is ok.
"
::= { ocmIfEntry 23 }
ocmIfCommissioningMode OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Data source not defined,
A: Commissioning mode is used
D: Normal mode
"
::= { ocmIfEntry 24 }
ocmIfModuleFailure OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The module HW has detected a failure.
A: The module has failed
D: The module is OK again
"
::= { ocmIfEntry 25 }
ocmIfConfigurationCommand OBJECT-TYPE
SYNTAX CommandString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Select which control mode to use.
normal - the switch toggle every hour
and measure both ports.
commissioning - the switch is set to one
port while adjusting surrounding boards.
"
::= { ocmIfEntry 26 }
ocmIfChangeConnectedPort OBJECT-TYPE
SYNTAX CommandString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Select which monitor port that is connected
to this ocm port.
"
::= { ocmIfEntry 27 }
ocmIfSaveReference OBJECT-TYPE
SYNTAX CommandString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Save current measurement as reference values
"
::= { ocmIfEntry 28 }
ocmIfPowerOffset OBJECT-TYPE
SYNTAX Integer32 (0..350)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An offset value added to all power levels to get
an accurate presentation of channel powers at the line
port.
Generally offset values depends upon board type connected.
oa - 20.0
roadm - 17.0
oa26c - 20.0
mdu40 - 20.0
other - 20.0
oaraed21hg - 20.0
oaraed20lg - 20.0
OA boards have more accurate values for power offset
named Monitor port insertion loss visible in the OA
interface.
Note however that the reference power level values
are not affected by a change of this offset. A new
reference calculation should be made after a change.
"
::= { ocmIfEntry 29 }
ocmIfConnectedBoardType OBJECT-TYPE
SYNTAX INTEGER {
oa (1),
roadm (2),
oa26c (3),
mdu40 (4),
other (5),
oaraed21hg (6),
oaraed20lg (7)}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"What board type that is connected to the ocm.
The power offset default value is changed
based on the chosen board type.
Please note that this function is not
applicable for mdu40lite boards.
"
DEFVAL { oa }
::= { ocmIfEntry 30 }
ocmIfChangeConnectedBoardType OBJECT-TYPE
SYNTAX CommandString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Select board type for the monitor port connected
to this ocm port.
"
::= { ocmIfEntry 31 }
ocmIfMaxPowerLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum received power level for this port
in units of 0.1 dBm.
"
::= { ocmIfEntry 32 }
ocmIfMinPowerLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum received power level for this port
in units of 0.1 dBm.
"
::= { ocmIfEntry 33 }
ocmIfDeltaPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The difference between the maximum and the minimum
received power level for this port in units of 0.1 dBm.
"
::= { ocmIfEntry 34 }
ocmIfChangePowerThreshold OBJECT-TYPE
SYNTAX CommandString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Select the power threshold for this ocm port.
If the measured power level is below the threshold, it
is regarded as no signal.
"
::= { ocmIfEntry 35 }
ocmIfChangePowerOffset OBJECT-TYPE
SYNTAX CommandString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Select the power offset for this ocm port.
The power offset is a value added to all power levels to get
an accurate presentation of channel powers at the line port.
"
::= { ocmIfEntry 36 }
ocmIfPowerOffsetAdjustment OBJECT-TYPE
SYNTAX Integer32 (0..350)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An offset adjustment added to the power offset to
mitigate the effects of differences between actual
power measured at the OCM and the configured power
offset value.
This adjustment allows the optical control loop to
regulate with better precision.
"
::= { ocmIfEntry 37 }
ocmIfSpacingMode OBJECT-TYPE
SYNTAX INTEGER {
spacing50GHz (1)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Spacing mode is configured for monitoring channel power
with the channel spacing of 50GHz.
spacing50GHz: interface with channels in 50 GHz intervals
"
DEFVAL { spacing50GHz }
::= { ocmIfEntry 38 }
ocmIfHighInputPower OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OCM module has detected a high input power.
A: OCM module has dectected high input power (above 20dBm)
on particular port.
D: Optical input power is within the limit (below 20dBm).
"
::= { ocmIfEntry 39 }
-- ----------------------------------------------------
-- Optical control channels
-- ----------------------------------------------------
ocmChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcmChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The channel list."
::= { ocmChannelList 1 }
ocmChannelEntry OBJECT-TYPE
SYNTAX OcmChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the channel list.
"
INDEX { ocmChannelIndex }
::= { ocmChannelTable 1 }
OcmChannelEntry ::=
SEQUENCE {
ocmChannelIndex Unsigned32,
ocmChannelName MgmtNameString,
ocmChannelFrequency LambdaFrequency,
ocmChannelPowerLevel Integer32,
ocmChannelUpdateLastChangeTime DateAndTime,
ocmChannelOcmRefIfIndex Unsigned32,
ocmChannelReferencePowerLevel Integer32,
ocmChannelReferenceTime DisplayString,
ocmChannelSaveReference CommandString}
ocmChannelIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An arbitrary index assigned to each entry.
"
::= { ocmChannelEntry 1 }
ocmChannelName OBJECT-TYPE
SYNTAX MgmtNameString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The management name of the interface, for
example 'ocm:1:2:1', where the first number
indicates sub-rack, the second slot number and
the third is the port number.
Examples:
ocm:s:s:p - Optical channel module interface
"
::= { ocmChannelEntry 2 }
ocmChannelFrequency OBJECT-TYPE
SYNTAX LambdaFrequency
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Freqency in hundreds of GHz (0.01 GHz).
"
::= { ocmChannelEntry 3 }
ocmChannelPowerLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The received power level in units of 0.1 dBm.
"
::= { ocmChannelEntry 4 }
ocmChannelUpdateLastChangeTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time when last measurement was done.
"
::= { ocmChannelEntry 5 }
ocmChannelOcmRefIfIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SNMP-index of the OCM i/f object related to this
object.
"
DEFVAL { 1 }
::= { ocmChannelEntry 6 }
ocmChannelReferencePowerLevel OBJECT-TYPE
SYNTAX Integer32 (-1000..1000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The reference power level in units of 0.1 dBm.
"
DEFVAL { 1000 }
::= { ocmChannelEntry 7 }
ocmChannelReferenceTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time where reference values were saved.
"
::= { ocmChannelEntry 8 }
ocmChannelSaveReference OBJECT-TYPE
SYNTAX CommandString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Save current measurement as reference values
"
::= { ocmChannelEntry 9 }
-- ----------------------------------------------------
-- Notifications
-- ----------------------------------------------------
-- n/a
-- ----------------------------------------------------
-- Object and event groups
-- ----------------------------------------------------
ocmGeneralGroup OBJECT-GROUP
OBJECTS {
ocmGeneralLastChangeTime,
ocmGeneralStateLastChangeTime,
ocmGeneralOcmIfTableSize }
STATUS current
DESCRIPTION
"The general objects."
::= { lumOcmGroups 1 }
ocmIfGroup OBJECT-GROUP
OBJECTS {
ocmIfIndex,
ocmIfName,
ocmIfDescr,
ocmIfSubrack,
ocmIfSlot,
ocmIfRxPort,
ocmIfInvPhysIndexOrZero,
ocmIfAdminStatus,
ocmIfOperStatus,
ocmIfPowerThreshold,
ocmIfUpdateLastChangeTime,
ocmIfConnectedSubrack,
ocmIfConnectedSlot,
ocmIfConnectedPort,
ocmIfActivePort,
ocmIfControlMode,
ocmIfReferenceTime,
ocmIfSwitchFailure,
ocmIfDataSourceNotDefined,
ocmIfCommissioningMode,
ocmIfModuleFailure,
ocmIfConfigurationCommand,
ocmIfChangeConnectedPort,
ocmIfSaveReference,
ocmIfPowerOffset,
ocmIfConnectedBoardType,
ocmIfChangeConnectedBoardType,
ocmIfMaxPowerLevel,
ocmIfMinPowerLevel,
ocmIfDeltaPower }
STATUS deprecated
DESCRIPTION
"The ocm interface objects."
::= { lumOcmGroups 2 }
ocmChannelGroup OBJECT-GROUP
OBJECTS {
ocmChannelIndex,
ocmChannelName,
ocmChannelFrequency,
ocmChannelPowerLevel,
ocmChannelUpdateLastChangeTime,
ocmChannelOcmRefIfIndex,
ocmChannelReferencePowerLevel }
STATUS deprecated
DESCRIPTION
"The ocm channel objects."
::= { lumOcmGroups 3 }
ocmIfGroupV2 OBJECT-GROUP
OBJECTS {
ocmIfIndex,
ocmIfName,
ocmIfDescr,
ocmIfSubrack,
ocmIfSlot,
ocmIfRxPort,
ocmIfInvPhysIndexOrZero,
ocmIfAdminStatus,
ocmIfOperStatus,
ocmIfPowerThreshold,
ocmIfUpdateLastChangeTime,
ocmIfConnectedSubrack,
ocmIfConnectedSlot,
ocmIfConnectedPort,
ocmIfActivePort,
ocmIfControlMode,
ocmIfReferenceTime,
ocmIfSwitchFailure,
ocmIfDataSourceNotDefined,
ocmIfCommissioningMode,
ocmIfModuleFailure,
ocmIfConfigurationCommand,
ocmIfChangeConnectedPort,
ocmIfSaveReference,
ocmIfPowerOffset,
ocmIfConnectedBoardType,
ocmIfChangeConnectedBoardType,
ocmIfMaxPowerLevel,
ocmIfMinPowerLevel,
ocmIfDeltaPower,
ocmIfChangePowerThreshold,
ocmIfChangePowerOffset }
STATUS deprecated
DESCRIPTION
"The ocm interface objects."
::= { lumOcmGroups 4 }
ocmIfGroupV3 OBJECT-GROUP
OBJECTS {
ocmIfIndex,
ocmIfName,
ocmIfDescr,
ocmIfSubrack,
ocmIfSlot,
ocmIfRxPort,
ocmIfInvPhysIndexOrZero,
ocmIfAdminStatus,
ocmIfOperStatus,
ocmIfPowerThreshold,
ocmIfUpdateLastChangeTime,
ocmIfConnectedSubrack,
ocmIfConnectedSlot,
ocmIfConnectedPort,
ocmIfActivePort,
ocmIfControlMode,
ocmIfReferenceTime,
ocmIfSwitchFailure,
ocmIfDataSourceNotDefined,
ocmIfCommissioningMode,
ocmIfModuleFailure,
ocmIfConfigurationCommand,
ocmIfChangeConnectedPort,
ocmIfSaveReference,
ocmIfPowerOffset,
ocmIfConnectedBoardType,
ocmIfChangeConnectedBoardType,
ocmIfMaxPowerLevel,
ocmIfMinPowerLevel,
ocmIfDeltaPower,
ocmIfChangePowerThreshold,
ocmIfChangePowerOffset,
ocmIfPowerOffsetAdjustment }
STATUS deprecated
DESCRIPTION
"The ocm interface objects."
::= { lumOcmGroups 5 }
ocmChannelGroupV2 OBJECT-GROUP
OBJECTS {
ocmChannelIndex,
ocmChannelName,
ocmChannelFrequency,
ocmChannelPowerLevel,
ocmChannelUpdateLastChangeTime,
ocmChannelOcmRefIfIndex,
ocmChannelReferencePowerLevel,
ocmChannelReferenceTime,
ocmChannelSaveReference }
STATUS current
DESCRIPTION
"The ocm channel objects."
::= { lumOcmGroups 6 }
ocmIfGroupV4 OBJECT-GROUP
OBJECTS {
ocmIfIndex,
ocmIfName,
ocmIfDescr,
ocmIfSubrack,
ocmIfSlot,
ocmIfRxPort,
ocmIfInvPhysIndexOrZero,
ocmIfAdminStatus,
ocmIfOperStatus,
ocmIfPowerThreshold,
ocmIfUpdateLastChangeTime,
ocmIfConnectedSubrack,
ocmIfConnectedSlot,
ocmIfConnectedPort,
ocmIfActivePort,
ocmIfControlMode,
ocmIfReferenceTime,
ocmIfSwitchFailure,
ocmIfDataSourceNotDefined,
ocmIfCommissioningMode,
ocmIfModuleFailure,
ocmIfConfigurationCommand,
ocmIfChangeConnectedPort,
ocmIfSaveReference,
ocmIfPowerOffset,
ocmIfConnectedBoardType,
ocmIfChangeConnectedBoardType,
ocmIfMaxPowerLevel,
ocmIfMinPowerLevel,
ocmIfDeltaPower,
ocmIfChangePowerThreshold,
ocmIfChangePowerOffset,
ocmIfPowerOffsetAdjustment,
ocmIfSpacingMode,
ocmIfHighInputPower }
STATUS current
DESCRIPTION
"The ocm interface objects."
::= { lumOcmGroups 7 }
-- ----------------------------------------------------
-- Compliance
-- ----------------------------------------------------
lumOcmBasicComplV1 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OCM MIB V1."
MODULE
MANDATORY-GROUPS {
ocmGeneralGroup,
ocmIfGroup,
ocmChannelGroup }
::= { lumOcmCompl 1 }
lumOcmBasicComplV2 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OCM MIB V2 (14.0)."
MODULE
MANDATORY-GROUPS {
ocmGeneralGroup,
ocmIfGroupV2,
ocmChannelGroup }
::= { lumOcmCompl 2 }
lumOcmBasicComplV3 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OCM MIB V2 (23.0)."
MODULE
MANDATORY-GROUPS {
ocmGeneralGroup,
ocmIfGroupV3,
ocmChannelGroup }
::= { lumOcmCompl 3 }
lumOcmBasicComplV4 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OCM MIB V2 (30.0)."
MODULE
MANDATORY-GROUPS {
ocmGeneralGroup,
ocmIfGroupV3,
ocmChannelGroupV2 }
::= { lumOcmCompl 4 }
lumOcmBasicComplV5 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Basic implementation requirements for the OCM MIB V2 (31.0)."
MODULE
MANDATORY-GROUPS {
ocmGeneralGroup,
ocmIfGroupV4,
ocmChannelGroupV2 }
::= { lumOcmCompl 5 }
-- ----------------------------------------------------
-- Minimal Compliance
-- ----------------------------------------------------
lumOcmMinimalComplV1 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Minimal implementation requirements for the OCM MIB V1."
MODULE
MANDATORY-GROUPS {
ocmGeneralGroup,
ocmIfGroup }
::= { lumOcmMinimalCompl 1 }
END