1143 lines
29 KiB
Plaintext
1143 lines
29 KiB
Plaintext
LUM-OCM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Integer32
|
|
FROM SNMPv2-SMI
|
|
OBJECT-GROUP, MODULE-COMPLIANCE
|
|
FROM SNMPv2-CONF
|
|
DisplayString, DateAndTime
|
|
FROM SNMPv2-TC
|
|
lumModules, lumOcmMIB
|
|
FROM LUM-REG
|
|
FaultStatus, MgmtNameString, SubrackNumber, SlotNumber, PortNumber,
|
|
LambdaFrequency, BoardOrInterfaceOperStatus, BoardOrInterfaceAdminStatus,
|
|
CommandString
|
|
FROM LUM-TC;
|
|
|
|
lumOcmMIBModule MODULE-IDENTITY
|
|
LAST-UPDATED
|
|
"201806150000Z" -- June 15th 2018
|
|
ORGANIZATION
|
|
"Infinera Corporation"
|
|
CONTACT-INFO
|
|
"techsupport@infinera.com"
|
|
DESCRIPTION
|
|
"The optical control interface MIB.
|
|
|
|
- General
|
|
|
|
- Monitor interfaces
|
|
|
|
Note that, every time a get operation is performed and both ports are set
|
|
to admin status up, the switch will switch to update both ports. (unless
|
|
commissioning mode) The guaranteed durability of switching is 10 million times.
|
|
That means, if you switch (perform a get operation) more than every 50 second,
|
|
product lifetime of 15 years can not be guaranteed.
|
|
|
|
"
|
|
REVISION
|
|
"201806150000Z" -- June 15th 2018
|
|
DESCRIPTION
|
|
" Changes made for release r31.0:
|
|
- Added ocmIfSpacingMode and ocmIfHighInputPower in ocmIfEntry."
|
|
REVISION
|
|
"201712150000Z" -- Dec 15th 2017
|
|
DESCRIPTION
|
|
" Changes made for release r30.0:
|
|
- Added ocmChannelReferenceTime and ocmChannelSaveReference action in ocmChannel."
|
|
REVISION
|
|
"201706150000Z" -- June 15th 2017
|
|
DESCRIPTION
|
|
"Changes made for release r29.0:
|
|
- Changed ORGANIZATION and CONTACT-INFO"
|
|
REVISION
|
|
"201601110000Z" -- Jan 11th 2016
|
|
DESCRIPTION
|
|
"Added default value notPresent for operStatus."
|
|
REVISION
|
|
"201405160000Z" -- May 16th 2014
|
|
DESCRIPTION
|
|
"Added a parameter for offset adjustment which will allow for better
|
|
regulation in the optical control loop"
|
|
REVISION
|
|
"200801160000Z" -- January 16th 2008
|
|
DESCRIPTION
|
|
"First version."
|
|
|
|
::= { lumModules 33 }
|
|
|
|
|
|
-- ----------------------------------------------------
|
|
-- Conformance area, containing groups and complicance
|
|
-- specifications.
|
|
-- ----------------------------------------------------
|
|
|
|
lumOcmConfs OBJECT IDENTIFIER ::= { lumOcmMIB 1 }
|
|
lumOcmGroups OBJECT IDENTIFIER ::= { lumOcmConfs 1 }
|
|
lumOcmCompl OBJECT IDENTIFIER ::= { lumOcmConfs 2 }
|
|
lumOcmMinimalGroups OBJECT IDENTIFIER ::= { lumOcmConfs 3 }
|
|
lumOcmMinimalCompl OBJECT IDENTIFIER ::= { lumOcmConfs 4 }
|
|
|
|
|
|
-- ----------------------------------------------------
|
|
-- Root for objects in the ocm MIB
|
|
-- ----------------------------------------------------
|
|
|
|
lumOcmMIBObjects OBJECT IDENTIFIER ::= { lumOcmMIB 2 }
|
|
|
|
|
|
-- ----------------------------------------------------
|
|
-- This MIB contains the following groups:
|
|
-- ----------------------------------------------------
|
|
|
|
ocmGeneral OBJECT IDENTIFIER ::= { lumOcmMIBObjects 1 }
|
|
ocmIfList OBJECT IDENTIFIER ::= { lumOcmMIBObjects 2 }
|
|
ocmChannelList OBJECT IDENTIFIER ::= { lumOcmMIBObjects 3 }
|
|
lumentisOcmNotifications OBJECT IDENTIFIER ::= { lumOcmMIBObjects 4 }
|
|
|
|
-- ----------------------------------------------------
|
|
-- Textual Conventions
|
|
-- ----------------------------------------------------
|
|
|
|
-- ----------------------------------------------------
|
|
-- General group
|
|
-- ----------------------------------------------------
|
|
|
|
ocmGeneralLastChangeTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time when the configuration of the MIB
|
|
was last changed.
|
|
|
|
"
|
|
::= { ocmGeneral 1 }
|
|
|
|
ocmGeneralStateLastChangeTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time when the state of the MIB was last
|
|
changed.
|
|
|
|
"
|
|
::= { ocmGeneral 2 }
|
|
|
|
ocmGeneralOcmIfTableSize OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Size of table
|
|
|
|
"
|
|
::= { ocmGeneral 3 }
|
|
|
|
ocmGeneralOcmChannelTableSize OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Size of table
|
|
|
|
"
|
|
::= { ocmGeneral 4 }
|
|
|
|
-- ----------------------------------------------------
|
|
-- Optical control interfaces
|
|
-- ----------------------------------------------------
|
|
|
|
ocmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OcmIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface list."
|
|
::= { ocmIfList 1 }
|
|
|
|
ocmIfEntry OBJECT-TYPE
|
|
SYNTAX OcmIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the interface list.
|
|
|
|
"
|
|
INDEX { ocmIfIndex }
|
|
::= { ocmIfTable 1 }
|
|
|
|
OcmIfEntry ::=
|
|
SEQUENCE {
|
|
ocmIfIndex Unsigned32,
|
|
ocmIfName MgmtNameString,
|
|
ocmIfDescr DisplayString,
|
|
ocmIfSubrack SubrackNumber,
|
|
ocmIfSlot SlotNumber,
|
|
ocmIfRxPort PortNumber,
|
|
ocmIfInvPhysIndexOrZero Unsigned32,
|
|
ocmIfAdminStatus BoardOrInterfaceAdminStatus,
|
|
ocmIfOperStatus BoardOrInterfaceOperStatus,
|
|
ocmIfPowerThreshold Integer32,
|
|
ocmIfPowerOffset Integer32,
|
|
ocmIfMaxPowerLevel Integer32,
|
|
ocmIfMinPowerLevel Integer32,
|
|
ocmIfDeltaPower Integer32,
|
|
ocmIfConnectedBoardType INTEGER,
|
|
ocmIfUpdateLastChangeTime DateAndTime,
|
|
ocmIfConnectedSubrack SubrackNumber,
|
|
ocmIfConnectedSlot SlotNumber,
|
|
ocmIfConnectedPort PortNumber,
|
|
ocmIfActivePort PortNumber,
|
|
ocmIfControlMode INTEGER,
|
|
ocmIfReferenceTime DisplayString,
|
|
ocmIfSwitchFailure FaultStatus,
|
|
ocmIfDataSourceNotDefined FaultStatus,
|
|
ocmIfCommissioningMode FaultStatus,
|
|
ocmIfModuleFailure FaultStatus,
|
|
ocmIfConfigurationCommand CommandString,
|
|
ocmIfChangeConnectedPort CommandString,
|
|
ocmIfSaveReference CommandString,
|
|
ocmIfChangeConnectedBoardType CommandString,
|
|
ocmIfChangePowerThreshold CommandString,
|
|
ocmIfChangePowerOffset CommandString,
|
|
ocmIfPowerOffsetAdjustment Integer32,
|
|
ocmIfSpacingMode Integer32,
|
|
ocmIfHighInputPower FaultStatus }
|
|
|
|
|
|
ocmIfIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An arbitrary index assigned to each entry.
|
|
|
|
"
|
|
::= { ocmIfEntry 1 }
|
|
|
|
ocmIfName OBJECT-TYPE
|
|
SYNTAX MgmtNameString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The management name of the interface, for
|
|
example 'ocm:1:2:1', where the first number
|
|
indicates sub-rack, the second slot number and
|
|
the third is the port number.
|
|
Examples:
|
|
|
|
ocm:s:s:p - Optical channel module interface
|
|
|
|
"
|
|
::= { ocmIfEntry 2 }
|
|
|
|
ocmIfDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User configurable label.
|
|
|
|
"
|
|
DEFVAL { "" }
|
|
::= { ocmIfEntry 3 }
|
|
|
|
ocmIfSubrack OBJECT-TYPE
|
|
SYNTAX SubrackNumber
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of the subrack where the interface
|
|
is located.
|
|
|
|
"
|
|
::= { ocmIfEntry 4 }
|
|
|
|
ocmIfSlot OBJECT-TYPE
|
|
SYNTAX SlotNumber
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of the slot where the interface is
|
|
located.
|
|
|
|
"
|
|
::= { ocmIfEntry 5 }
|
|
|
|
ocmIfRxPort OBJECT-TYPE
|
|
SYNTAX PortNumber
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of the port where the RX-side of
|
|
the interface is located.
|
|
|
|
"
|
|
::= { ocmIfEntry 6 }
|
|
|
|
ocmIfInvPhysIndexOrZero OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The row in the invPhysTable for this interface.
|
|
Set to 0 if not known.
|
|
|
|
"
|
|
::= { ocmIfEntry 7 }
|
|
|
|
ocmIfAdminStatus OBJECT-TYPE
|
|
SYNTAX BoardOrInterfaceAdminStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administrative state for the interface.
|
|
|
|
down - The interface should be inactive.
|
|
|
|
service - The interface is activated but alarms
|
|
are suppressed. Intended for use during service
|
|
or re-configuration. When service is concluded
|
|
adminStatus should be set to 'up' again.
|
|
|
|
up - The interface should be activated when
|
|
it becomes available. Alarms are not suppressed.
|
|
|
|
"
|
|
DEFVAL { up }
|
|
::= { ocmIfEntry 8 }
|
|
|
|
ocmIfOperStatus OBJECT-TYPE
|
|
SYNTAX BoardOrInterfaceOperStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operational state for the interface.
|
|
|
|
notPresent - The physical resources are not
|
|
available.
|
|
|
|
down - The interface is de-activated or the are
|
|
faults preventing it from going to the 'up'-state.
|
|
|
|
up - The interface is operational.
|
|
|
|
"
|
|
DEFVAL { notPresent }
|
|
::= { ocmIfEntry 9 }
|
|
|
|
ocmIfPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (-50..100)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The threshold for power levels. If the measured
|
|
power level is below the threshold, it is regarded
|
|
as no signal.
|
|
|
|
For OCM8p:
|
|
|
|
Default -13dBm
|
|
|
|
Range -35 to 100dBm
|
|
|
|
For OCM2p:
|
|
|
|
"
|
|
DEFVAL { -24 }
|
|
::= { ocmIfEntry 12 }
|
|
|
|
ocmIfUpdateLastChangeTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time when the last measurement was done.
|
|
|
|
"
|
|
::= { ocmIfEntry 13 }
|
|
|
|
ocmIfConnectedSubrack OBJECT-TYPE
|
|
SYNTAX SubrackNumber
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of the subrack where the connected
|
|
interface is located. (0 is not valid)
|
|
|
|
"
|
|
DEFVAL { 0 }
|
|
::= { ocmIfEntry 14 }
|
|
|
|
ocmIfConnectedSlot OBJECT-TYPE
|
|
SYNTAX SlotNumber
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of the slot where the connected
|
|
interface is located. (not possible to set 0, 1,
|
|
19-22, oa/roadm can not be placed in those slots)
|
|
|
|
"
|
|
DEFVAL { 0 }
|
|
::= { ocmIfEntry 15 }
|
|
|
|
ocmIfConnectedPort OBJECT-TYPE
|
|
SYNTAX PortNumber
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of the connected port.
|
|
(the tx port number).
|
|
1 or 3 for OA,
|
|
5 for 1x2ROADM/100G/50G,
|
|
9 for 1x4ROADM/100G,ROADM1x4f,
|
|
17 for 1x8ROADM/50G,
|
|
19 for ROADM1x9f,
|
|
1 for OA26C,
|
|
5 for OARAED21HG
|
|
81 for MDU40.
|
|
and 1 to 82 for other boards.
|
|
|
|
"
|
|
DEFVAL { 0 }
|
|
::= { ocmIfEntry 16 }
|
|
|
|
ocmIfActivePort OBJECT-TYPE
|
|
SYNTAX PortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of the active port.
|
|
Only valid when commissioning mode.
|
|
|
|
"
|
|
DEFVAL { 1 }
|
|
::= { ocmIfEntry 17 }
|
|
|
|
ocmIfControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
commissioning (2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"What mode the ocm is in.
|
|
|
|
normal - the switch toggle every hour
|
|
and measure both ports.
|
|
|
|
commissioning - the switch is set to one active
|
|
port and measurement is made continuously on this port.
|
|
After 15 minutes it will change back to normal mode.
|
|
Note that it is not possible to get updated
|
|
values on port that is not chosen as active during
|
|
commissioning mode.
|
|
|
|
"
|
|
DEFVAL { normal }
|
|
::= { ocmIfEntry 18 }
|
|
|
|
ocmIfReferenceTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time where reference values were saved.
|
|
|
|
"
|
|
::= { ocmIfEntry 21 }
|
|
|
|
ocmIfSwitchFailure OBJECT-TYPE
|
|
SYNTAX FaultStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Switch failure.
|
|
|
|
A: The switch is stuck and it is not possible
|
|
to change port. It is not sure if it the values
|
|
comes from the expected port.
|
|
|
|
D: The switch works as expected.
|
|
|
|
"
|
|
::= { ocmIfEntry 22 }
|
|
|
|
ocmIfDataSourceNotDefined OBJECT-TYPE
|
|
SYNTAX FaultStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Data source not defined,
|
|
|
|
A: No connected slot, connected subrack
|
|
nor connected port is defined.
|
|
|
|
D: Connected slot, connected subrack and
|
|
connected port is ok.
|
|
|
|
"
|
|
::= { ocmIfEntry 23 }
|
|
|
|
ocmIfCommissioningMode OBJECT-TYPE
|
|
SYNTAX FaultStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Data source not defined,
|
|
|
|
A: Commissioning mode is used
|
|
|
|
D: Normal mode
|
|
|
|
"
|
|
::= { ocmIfEntry 24 }
|
|
|
|
ocmIfModuleFailure OBJECT-TYPE
|
|
SYNTAX FaultStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The module HW has detected a failure.
|
|
|
|
A: The module has failed
|
|
|
|
D: The module is OK again
|
|
|
|
"
|
|
::= { ocmIfEntry 25 }
|
|
|
|
ocmIfConfigurationCommand OBJECT-TYPE
|
|
SYNTAX CommandString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Select which control mode to use.
|
|
|
|
normal - the switch toggle every hour
|
|
and measure both ports.
|
|
|
|
commissioning - the switch is set to one
|
|
port while adjusting surrounding boards.
|
|
|
|
|
|
"
|
|
::= { ocmIfEntry 26 }
|
|
|
|
ocmIfChangeConnectedPort OBJECT-TYPE
|
|
SYNTAX CommandString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Select which monitor port that is connected
|
|
to this ocm port.
|
|
|
|
"
|
|
::= { ocmIfEntry 27 }
|
|
|
|
ocmIfSaveReference OBJECT-TYPE
|
|
SYNTAX CommandString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Save current measurement as reference values
|
|
|
|
"
|
|
::= { ocmIfEntry 28 }
|
|
|
|
ocmIfPowerOffset OBJECT-TYPE
|
|
SYNTAX Integer32 (0..350)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An offset value added to all power levels to get
|
|
an accurate presentation of channel powers at the line
|
|
port.
|
|
|
|
Generally offset values depends upon board type connected.
|
|
oa - 20.0
|
|
roadm - 17.0
|
|
oa26c - 20.0
|
|
mdu40 - 20.0
|
|
other - 20.0
|
|
oaraed21hg - 20.0
|
|
oaraed20lg - 20.0
|
|
|
|
OA boards have more accurate values for power offset
|
|
named Monitor port insertion loss visible in the OA
|
|
interface.
|
|
|
|
Note however that the reference power level values
|
|
are not affected by a change of this offset. A new
|
|
reference calculation should be made after a change.
|
|
|
|
"
|
|
::= { ocmIfEntry 29 }
|
|
|
|
ocmIfConnectedBoardType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
oa (1),
|
|
roadm (2),
|
|
oa26c (3),
|
|
mdu40 (4),
|
|
other (5),
|
|
oaraed21hg (6),
|
|
oaraed20lg (7)}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"What board type that is connected to the ocm.
|
|
The power offset default value is changed
|
|
based on the chosen board type.
|
|
Please note that this function is not
|
|
applicable for mdu40lite boards.
|
|
|
|
"
|
|
DEFVAL { oa }
|
|
::= { ocmIfEntry 30 }
|
|
|
|
ocmIfChangeConnectedBoardType OBJECT-TYPE
|
|
SYNTAX CommandString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Select board type for the monitor port connected
|
|
to this ocm port.
|
|
|
|
"
|
|
::= { ocmIfEntry 31 }
|
|
|
|
ocmIfMaxPowerLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum received power level for this port
|
|
in units of 0.1 dBm.
|
|
|
|
"
|
|
::= { ocmIfEntry 32 }
|
|
|
|
ocmIfMinPowerLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum received power level for this port
|
|
in units of 0.1 dBm.
|
|
|
|
"
|
|
::= { ocmIfEntry 33 }
|
|
|
|
ocmIfDeltaPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The difference between the maximum and the minimum
|
|
received power level for this port in units of 0.1 dBm.
|
|
|
|
"
|
|
::= { ocmIfEntry 34 }
|
|
|
|
ocmIfChangePowerThreshold OBJECT-TYPE
|
|
SYNTAX CommandString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Select the power threshold for this ocm port.
|
|
|
|
If the measured power level is below the threshold, it
|
|
is regarded as no signal.
|
|
|
|
"
|
|
::= { ocmIfEntry 35 }
|
|
|
|
ocmIfChangePowerOffset OBJECT-TYPE
|
|
SYNTAX CommandString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Select the power offset for this ocm port.
|
|
|
|
The power offset is a value added to all power levels to get
|
|
an accurate presentation of channel powers at the line port.
|
|
|
|
"
|
|
::= { ocmIfEntry 36 }
|
|
|
|
ocmIfPowerOffsetAdjustment OBJECT-TYPE
|
|
SYNTAX Integer32 (0..350)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An offset adjustment added to the power offset to
|
|
mitigate the effects of differences between actual
|
|
power measured at the OCM and the configured power
|
|
offset value.
|
|
This adjustment allows the optical control loop to
|
|
regulate with better precision.
|
|
|
|
"
|
|
::= { ocmIfEntry 37 }
|
|
|
|
ocmIfSpacingMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
spacing50GHz (1)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Spacing mode is configured for monitoring channel power
|
|
with the channel spacing of 50GHz.
|
|
|
|
spacing50GHz: interface with channels in 50 GHz intervals
|
|
|
|
"
|
|
DEFVAL { spacing50GHz }
|
|
::= { ocmIfEntry 38 }
|
|
|
|
ocmIfHighInputPower OBJECT-TYPE
|
|
SYNTAX FaultStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The OCM module has detected a high input power.
|
|
|
|
A: OCM module has dectected high input power (above 20dBm)
|
|
on particular port.
|
|
|
|
D: Optical input power is within the limit (below 20dBm).
|
|
|
|
"
|
|
::= { ocmIfEntry 39 }
|
|
|
|
-- ----------------------------------------------------
|
|
-- Optical control channels
|
|
-- ----------------------------------------------------
|
|
|
|
ocmChannelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OcmChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The channel list."
|
|
|
|
::= { ocmChannelList 1 }
|
|
|
|
ocmChannelEntry OBJECT-TYPE
|
|
SYNTAX OcmChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the channel list.
|
|
|
|
"
|
|
INDEX { ocmChannelIndex }
|
|
::= { ocmChannelTable 1 }
|
|
|
|
OcmChannelEntry ::=
|
|
SEQUENCE {
|
|
ocmChannelIndex Unsigned32,
|
|
ocmChannelName MgmtNameString,
|
|
ocmChannelFrequency LambdaFrequency,
|
|
ocmChannelPowerLevel Integer32,
|
|
ocmChannelUpdateLastChangeTime DateAndTime,
|
|
ocmChannelOcmRefIfIndex Unsigned32,
|
|
ocmChannelReferencePowerLevel Integer32,
|
|
ocmChannelReferenceTime DisplayString,
|
|
ocmChannelSaveReference CommandString}
|
|
|
|
|
|
ocmChannelIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An arbitrary index assigned to each entry.
|
|
|
|
"
|
|
::= { ocmChannelEntry 1 }
|
|
|
|
ocmChannelName OBJECT-TYPE
|
|
SYNTAX MgmtNameString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The management name of the interface, for
|
|
example 'ocm:1:2:1', where the first number
|
|
indicates sub-rack, the second slot number and
|
|
the third is the port number.
|
|
Examples:
|
|
|
|
ocm:s:s:p - Optical channel module interface
|
|
|
|
"
|
|
::= { ocmChannelEntry 2 }
|
|
|
|
ocmChannelFrequency OBJECT-TYPE
|
|
SYNTAX LambdaFrequency
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Freqency in hundreds of GHz (0.01 GHz).
|
|
|
|
"
|
|
::= { ocmChannelEntry 3 }
|
|
|
|
ocmChannelPowerLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The received power level in units of 0.1 dBm.
|
|
|
|
"
|
|
::= { ocmChannelEntry 4 }
|
|
|
|
ocmChannelUpdateLastChangeTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time when last measurement was done.
|
|
|
|
"
|
|
::= { ocmChannelEntry 5 }
|
|
|
|
ocmChannelOcmRefIfIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP-index of the OCM i/f object related to this
|
|
object.
|
|
|
|
"
|
|
DEFVAL { 1 }
|
|
::= { ocmChannelEntry 6 }
|
|
|
|
ocmChannelReferencePowerLevel OBJECT-TYPE
|
|
SYNTAX Integer32 (-1000..1000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The reference power level in units of 0.1 dBm.
|
|
|
|
"
|
|
DEFVAL { 1000 }
|
|
::= { ocmChannelEntry 7 }
|
|
|
|
ocmChannelReferenceTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time where reference values were saved.
|
|
|
|
"
|
|
::= { ocmChannelEntry 8 }
|
|
|
|
ocmChannelSaveReference OBJECT-TYPE
|
|
SYNTAX CommandString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Save current measurement as reference values
|
|
|
|
"
|
|
::= { ocmChannelEntry 9 }
|
|
|
|
-- ----------------------------------------------------
|
|
-- Notifications
|
|
-- ----------------------------------------------------
|
|
|
|
-- n/a
|
|
|
|
-- ----------------------------------------------------
|
|
-- Object and event groups
|
|
-- ----------------------------------------------------
|
|
|
|
ocmGeneralGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ocmGeneralLastChangeTime,
|
|
ocmGeneralStateLastChangeTime,
|
|
ocmGeneralOcmIfTableSize }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The general objects."
|
|
::= { lumOcmGroups 1 }
|
|
|
|
ocmIfGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ocmIfIndex,
|
|
ocmIfName,
|
|
ocmIfDescr,
|
|
ocmIfSubrack,
|
|
ocmIfSlot,
|
|
ocmIfRxPort,
|
|
ocmIfInvPhysIndexOrZero,
|
|
ocmIfAdminStatus,
|
|
ocmIfOperStatus,
|
|
ocmIfPowerThreshold,
|
|
ocmIfUpdateLastChangeTime,
|
|
ocmIfConnectedSubrack,
|
|
ocmIfConnectedSlot,
|
|
ocmIfConnectedPort,
|
|
ocmIfActivePort,
|
|
ocmIfControlMode,
|
|
ocmIfReferenceTime,
|
|
ocmIfSwitchFailure,
|
|
ocmIfDataSourceNotDefined,
|
|
ocmIfCommissioningMode,
|
|
ocmIfModuleFailure,
|
|
ocmIfConfigurationCommand,
|
|
ocmIfChangeConnectedPort,
|
|
ocmIfSaveReference,
|
|
ocmIfPowerOffset,
|
|
ocmIfConnectedBoardType,
|
|
ocmIfChangeConnectedBoardType,
|
|
ocmIfMaxPowerLevel,
|
|
ocmIfMinPowerLevel,
|
|
ocmIfDeltaPower }
|
|
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The ocm interface objects."
|
|
::= { lumOcmGroups 2 }
|
|
|
|
ocmChannelGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ocmChannelIndex,
|
|
ocmChannelName,
|
|
ocmChannelFrequency,
|
|
ocmChannelPowerLevel,
|
|
ocmChannelUpdateLastChangeTime,
|
|
ocmChannelOcmRefIfIndex,
|
|
ocmChannelReferencePowerLevel }
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The ocm channel objects."
|
|
::= { lumOcmGroups 3 }
|
|
|
|
ocmIfGroupV2 OBJECT-GROUP
|
|
OBJECTS {
|
|
ocmIfIndex,
|
|
ocmIfName,
|
|
ocmIfDescr,
|
|
ocmIfSubrack,
|
|
ocmIfSlot,
|
|
ocmIfRxPort,
|
|
ocmIfInvPhysIndexOrZero,
|
|
ocmIfAdminStatus,
|
|
ocmIfOperStatus,
|
|
ocmIfPowerThreshold,
|
|
ocmIfUpdateLastChangeTime,
|
|
ocmIfConnectedSubrack,
|
|
ocmIfConnectedSlot,
|
|
ocmIfConnectedPort,
|
|
ocmIfActivePort,
|
|
ocmIfControlMode,
|
|
ocmIfReferenceTime,
|
|
ocmIfSwitchFailure,
|
|
ocmIfDataSourceNotDefined,
|
|
ocmIfCommissioningMode,
|
|
ocmIfModuleFailure,
|
|
ocmIfConfigurationCommand,
|
|
ocmIfChangeConnectedPort,
|
|
ocmIfSaveReference,
|
|
ocmIfPowerOffset,
|
|
ocmIfConnectedBoardType,
|
|
ocmIfChangeConnectedBoardType,
|
|
ocmIfMaxPowerLevel,
|
|
ocmIfMinPowerLevel,
|
|
ocmIfDeltaPower,
|
|
ocmIfChangePowerThreshold,
|
|
ocmIfChangePowerOffset }
|
|
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The ocm interface objects."
|
|
::= { lumOcmGroups 4 }
|
|
|
|
ocmIfGroupV3 OBJECT-GROUP
|
|
OBJECTS {
|
|
ocmIfIndex,
|
|
ocmIfName,
|
|
ocmIfDescr,
|
|
ocmIfSubrack,
|
|
ocmIfSlot,
|
|
ocmIfRxPort,
|
|
ocmIfInvPhysIndexOrZero,
|
|
ocmIfAdminStatus,
|
|
ocmIfOperStatus,
|
|
ocmIfPowerThreshold,
|
|
ocmIfUpdateLastChangeTime,
|
|
ocmIfConnectedSubrack,
|
|
ocmIfConnectedSlot,
|
|
ocmIfConnectedPort,
|
|
ocmIfActivePort,
|
|
ocmIfControlMode,
|
|
ocmIfReferenceTime,
|
|
ocmIfSwitchFailure,
|
|
ocmIfDataSourceNotDefined,
|
|
ocmIfCommissioningMode,
|
|
ocmIfModuleFailure,
|
|
ocmIfConfigurationCommand,
|
|
ocmIfChangeConnectedPort,
|
|
ocmIfSaveReference,
|
|
ocmIfPowerOffset,
|
|
ocmIfConnectedBoardType,
|
|
ocmIfChangeConnectedBoardType,
|
|
ocmIfMaxPowerLevel,
|
|
ocmIfMinPowerLevel,
|
|
ocmIfDeltaPower,
|
|
ocmIfChangePowerThreshold,
|
|
ocmIfChangePowerOffset,
|
|
ocmIfPowerOffsetAdjustment }
|
|
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The ocm interface objects."
|
|
::= { lumOcmGroups 5 }
|
|
|
|
ocmChannelGroupV2 OBJECT-GROUP
|
|
OBJECTS {
|
|
ocmChannelIndex,
|
|
ocmChannelName,
|
|
ocmChannelFrequency,
|
|
ocmChannelPowerLevel,
|
|
ocmChannelUpdateLastChangeTime,
|
|
ocmChannelOcmRefIfIndex,
|
|
ocmChannelReferencePowerLevel,
|
|
ocmChannelReferenceTime,
|
|
ocmChannelSaveReference }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ocm channel objects."
|
|
::= { lumOcmGroups 6 }
|
|
|
|
ocmIfGroupV4 OBJECT-GROUP
|
|
OBJECTS {
|
|
ocmIfIndex,
|
|
ocmIfName,
|
|
ocmIfDescr,
|
|
ocmIfSubrack,
|
|
ocmIfSlot,
|
|
ocmIfRxPort,
|
|
ocmIfInvPhysIndexOrZero,
|
|
ocmIfAdminStatus,
|
|
ocmIfOperStatus,
|
|
ocmIfPowerThreshold,
|
|
ocmIfUpdateLastChangeTime,
|
|
ocmIfConnectedSubrack,
|
|
ocmIfConnectedSlot,
|
|
ocmIfConnectedPort,
|
|
ocmIfActivePort,
|
|
ocmIfControlMode,
|
|
ocmIfReferenceTime,
|
|
ocmIfSwitchFailure,
|
|
ocmIfDataSourceNotDefined,
|
|
ocmIfCommissioningMode,
|
|
ocmIfModuleFailure,
|
|
ocmIfConfigurationCommand,
|
|
ocmIfChangeConnectedPort,
|
|
ocmIfSaveReference,
|
|
ocmIfPowerOffset,
|
|
ocmIfConnectedBoardType,
|
|
ocmIfChangeConnectedBoardType,
|
|
ocmIfMaxPowerLevel,
|
|
ocmIfMinPowerLevel,
|
|
ocmIfDeltaPower,
|
|
ocmIfChangePowerThreshold,
|
|
ocmIfChangePowerOffset,
|
|
ocmIfPowerOffsetAdjustment,
|
|
ocmIfSpacingMode,
|
|
ocmIfHighInputPower }
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ocm interface objects."
|
|
::= { lumOcmGroups 7 }
|
|
|
|
|
|
-- ----------------------------------------------------
|
|
-- Compliance
|
|
-- ----------------------------------------------------
|
|
|
|
lumOcmBasicComplV1 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Basic implementation requirements for the OCM MIB V1."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
ocmGeneralGroup,
|
|
ocmIfGroup,
|
|
ocmChannelGroup }
|
|
::= { lumOcmCompl 1 }
|
|
|
|
lumOcmBasicComplV2 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Basic implementation requirements for the OCM MIB V2 (14.0)."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
ocmGeneralGroup,
|
|
ocmIfGroupV2,
|
|
ocmChannelGroup }
|
|
::= { lumOcmCompl 2 }
|
|
|
|
lumOcmBasicComplV3 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Basic implementation requirements for the OCM MIB V2 (23.0)."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
ocmGeneralGroup,
|
|
ocmIfGroupV3,
|
|
ocmChannelGroup }
|
|
::= { lumOcmCompl 3 }
|
|
|
|
lumOcmBasicComplV4 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Basic implementation requirements for the OCM MIB V2 (30.0)."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
ocmGeneralGroup,
|
|
ocmIfGroupV3,
|
|
ocmChannelGroupV2 }
|
|
::= { lumOcmCompl 4 }
|
|
|
|
lumOcmBasicComplV5 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Basic implementation requirements for the OCM MIB V2 (31.0)."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
ocmGeneralGroup,
|
|
ocmIfGroupV4,
|
|
ocmChannelGroupV2 }
|
|
::= { lumOcmCompl 5 }
|
|
|
|
-- ----------------------------------------------------
|
|
-- Minimal Compliance
|
|
-- ----------------------------------------------------
|
|
|
|
lumOcmMinimalComplV1 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimal implementation requirements for the OCM MIB V1."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
ocmGeneralGroup,
|
|
ocmIfGroup }
|
|
::= { lumOcmMinimalCompl 1 }
|
|
|
|
END
|
|
|
|
|