mibs/MIBS/junose/Juniper-REDUNDANCY-MIB

571 lines
22 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- *****************************************************************************
-- Juniper-REDUNDANCY-MIB
--
-- Juniper Networks Enterprise MIB
-- REDUNDANCY MIB
--
-- Copyright (c) 2003 Juniper Networks Inc.
-- All Rights Reserved.
-- *****************************************************************************
Juniper-REDUNDANCY-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, TimeTicks
FROM SNMPv2-SMI
DisplayString, RowStatus, TruthValue, TEXTUAL-CONVENTION, DateAndTime
FROM SNMPv2-TC
sysUpTime
FROM SNMPv2-MIB
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
juniMibs
FROM Juniper-MIBs;
juniRedundancyMIB MODULE-IDENTITY
LAST-UPDATED "200312122104Z" -- 12-Dec-03 04:04 PM EST
ORGANIZATION "Juniper Networks, Inc."
CONTACT-INFO
" Juniper Networks, Inc.
Postal: 10 Technology Park Road
Westford, MA 01886-3146
USA
Tel: +1 978 589 5800
E-mail: mib@Juniper.net"
DESCRIPTION
"The redundancy configuration MIB for Juniper Networks enterprise."
-- Revision History
REVISION "200312120000Z" -- 12-Dec-03 - JUNOSe 6.0
DESCRIPTION
"Initial version of this MIB module."
::= { juniMibs 74 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Textual conventions
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
JuniRedundancyState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The current state of redundancy subsystem:
notKnown - Redundancy state is unknown.
fileSystemSyncing - Redundancy operation is based on file system
synchronization. SRP switchover stops forwarding.
disabled - Redundancy operation is based on high availability
model but high availability is not yet operational.
SRP switchover stops forwarding.
initializing - Redundancy operation is based on high availability
model and standby SRP is being bulk synchronized from
active SRP. SRP switchover stops forwarding.
pending - Redundancy operation is based on high availability
model and bulk synchronization of standby SRP completed.
SRP switchover stops forwarding.
active - Redundancy operation is based on high availability model
and high availability is fully operational. SRP
switchover does not stop forwarding."
SYNTAX INTEGER {
notKnown(1),
fileSystemSyncing(2),
disabled(3),
initializing(4),
pending(5),
active(6) }
JuniRedundancyMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The mode of the redundancy subsystem:
fileSystemSynchronization - SRP synchronization is based on file synchronization.
highAvailability - SRP synchronization is based on high availability
model that allows non-stop forwarding."
SYNTAX INTEGER {
fileSystemSynchronization(1),
highAvailability(2) }
JuniRedundancyResetReason ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Reason codes for the reset of active SRP or a line card that might result
in switch of control to standby SRP or spare line card.
none - No reset or switchover has occurred and indicates 'power-on'
situation.
notKnown - Reason is unknown.
userInitiated - A safe, manual reset was initiated by the user."
SYNTAX INTEGER {
none(1),
notKnown(2),
userInitiated(3) }
JuniRedundancySystemActivationType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Various kinds of system activation:
reload - System has reloaded, i.e., no switchover has occurred.
coldSwitch - System switched over from active to standby SRP and the
switchover involved reloading of line cards interrupting
forwarding.
warmSwitch - System switched over from active to standby SRP; line cards were
not reloaded during switchover and forwarding was uninterrupted."
SYNTAX INTEGER {
reload(1),
coldSwitch(2),
warmSwitch(3) }
JuniRedundancyResetType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Identifies the nature of the reset and slot types involved since the
system is powered on.
notKnown - Reset type is unknown.
srpReload - The reset involved reloading SRP slot(s).
srpSwitchover - The reset involved switchover of SRP slot(s).
linecardReload - The reset involved reloading the line card slot(s).
linecardSwitchover - The reset involved line card redundancy."
SYNTAX INTEGER {
notKnown(1),
srpReload(2),
srpSwitchover(3),
linecardReload(4),
linecardSwitchover(5) }
JuniRedundancyHistoryCommand ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Identifies the command to be performed on the system activation
history table.
keep - Retain history in persistent storage.
clear - Erase the current entries of juniRedundancySystemActivationHistoryTable."
SYNTAX INTEGER {
keep(1),
clear(2) }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- MIB Structure
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniRedundancyNotifications OBJECT IDENTIFIER ::= { juniRedundancyMIB 0 }
juniRedundancyObjects OBJECT IDENTIFIER ::= { juniRedundancyMIB 1 }
juniRedundancyMIBConformance OBJECT IDENTIFIER ::= { juniRedundancyMIB 2 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Managed object groups
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniRedundancyStatus OBJECT IDENTIFIER ::= {juniRedundancyObjects 1 }
juniRedundancyCfg OBJECT IDENTIFIER ::= {juniRedundancyObjects 2 }
juniRedundancyHistory OBJECT IDENTIFIER ::= {juniRedundancyObjects 3 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Managed objects for Redundancy
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
--
-- Status sub group definitions
--
juniRedundancyActiveSlot OBJECT-TYPE
SYNTAX Integer32(0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier for active SRP slot."
::= { juniRedundancyStatus 1 }
juniRedundancyActiveSlotState OBJECT-TYPE
SYNTAX JuniRedundancyState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of redundancy on active SRP."
::= { juniRedundancyStatus 2 }
juniRedundancyStandbySlot OBJECT-TYPE
SYNTAX Integer32(0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier for standby SRP slot."
::= { juniRedundancyStatus 3 }
juniRedundancyStandbySlotState OBJECT-TYPE
SYNTAX JuniRedundancyState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of redundancy on standby SRP."
::= { juniRedundancyStatus 4 }
juniRedundancyLastResetReason OBJECT-TYPE
SYNTAX JuniRedundancyResetReason
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The reason for the last SRP reset."
::= { juniRedundancyStatus 5 }
juniRedundancyLastSystemActivationTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUptime when the system is operational either
following a reload or a switchover. The value 0 is a special
value to indicate 'from reset'."
::= { juniRedundancyStatus 6 }
juniRedundancyLastSystemActivationType OBJECT-TYPE
SYNTAX JuniRedundancySystemActivationType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of last SRP activation when the system became operational."
::= { juniRedundancyStatus 7 }
juniRedundancyHaActiveTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUptime when active SRP enters 'active' state as
indicated in juniRedundancyActiveSlotState object. The value is 0 in
file system synchronization redundancy mode."
::= { juniRedundancyStatus 8 }
--
-- Cfg sub group definitions
--
juniRedundancyNotifsEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allows enabling and disabling of redundancy subsystem notifications."
DEFVAL { true }
::= { juniRedundancyCfg 1 }
juniRedundancyCfgRedundancyMode OBJECT-TYPE
SYNTAX JuniRedundancyMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the redundancy mode configured on the system."
DEFVAL { fileSystemSynchronization }
::= { juniRedundancyCfg 2 }
--
-- History sub group definitions
--
juniRedundancySystemActivationHistoryTableMaxLength OBJECT-TYPE
SYNTAX Integer32(0..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum number of entries allowed in juniRedundancySystemActivationHistoryTable.
A value of 0 will result in no history being displayed in
juniRedundancySystemActivationHistoryTable."
DEFVAL { 0 }
::= { juniRedundancyHistory 1 }
juniRedundancySystemActivationHistoryCommand OBJECT-TYPE
SYNTAX JuniRedundancyHistoryCommand
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A control variable to perform certain operations on
juniRedundancySystemActivationHistoryTable."
DEFVAL { keep }
::= { juniRedundancyHistory 2 }
juniRedundancySystemActivationHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniRedundancySystemActivationHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that tracks the history of all reloads and switchovers that have
occurred since system is powered on. The maximum number of entries permissible
in this table is defined by juniRedundancySystemActivationHistoryTableMaxLength.
When the number of entries in the table reaches the maximum limit, the next
entry would replace the oldest existing entry in the table."
::= { juniRedundancyHistory 3 }
juniRedundancySystemActivationHistoryEntry OBJECT-TYPE
SYNTAX JuniRedundancySystemActivationHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entries in this table contain the reload and switchover information.
Each entry in the table is indexed by juniRedundancySystemActivationHistoryIndex.
The index wraps around to 1 after reaching the maximum value."
INDEX { juniRedundancySystemActivationHistoryIndex }
::= { juniRedundancySystemActivationHistoryTable 1 }
JuniRedundancySystemActivationHistoryEntry ::= SEQUENCE {
juniRedundancySystemActivationHistoryIndex Integer32,
juniRedundancyHistoryResetType JuniRedundancyResetType,
juniRedundancyHistoryActivationType JuniRedundancySystemActivationType,
juniRedundancyHistoryPrevActiveSlot Integer32,
juniRedundancyHistoryPrevActiveRelease DisplayString,
juniRedundancyHistoryCurrActiveSlot Integer32,
juniRedundancyHistoryCurrActiveRelease DisplayString,
juniRedundancyHistoryResetReason JuniRedundancyResetReason,
juniRedundancyHistoryActivationTime DateAndTime }
juniRedundancySystemActivationHistoryIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An integer value for the purpose of indexing system
activation history table. After reaching maximum value as
indicated by juniRedundancySystemActivationHistoryTableMaxLength,
it wraps around to 1."
::= { juniRedundancySystemActivationHistoryEntry 1 }
juniRedundancyHistoryResetType OBJECT-TYPE
SYNTAX JuniRedundancyResetType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the nature of the reset - reload or switchover - and the slot
types involved. Depending on the value of this object, certain elements
of JuniRedundancySystemActivationHistoryEntry will not be applicable."
::= { juniRedundancySystemActivationHistoryEntry 2 }
juniRedundancyHistoryActivationType OBJECT-TYPE
SYNTAX JuniRedundancySystemActivationType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the activation type of the particular historical system
activation entry with respect to the slot types involved."
::= { juniRedundancySystemActivationHistoryEntry 3 }
juniRedundancyHistoryPrevActiveSlot OBJECT-TYPE
SYNTAX Integer32(0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the slot number of active SRP or line card that went down."
::= { juniRedundancySystemActivationHistoryEntry 4 }
juniRedundancyHistoryPrevActiveRelease OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the system-wide boot release file name of the slot indicated
by juniRedundancyHistoryPrevActiveSlot."
::= { juniRedundancySystemActivationHistoryEntry 5 }
juniRedundancyHistoryCurrActiveSlot OBJECT-TYPE
SYNTAX Integer32(0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the slot number of standby SRP or spare line card that took over."
::= { juniRedundancySystemActivationHistoryEntry 6 }
juniRedundancyHistoryCurrActiveRelease OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the system-wide boot release file name of the slot indicated
by juniRedundancyHistoryCurrActiveSlot."
::= { juniRedundancySystemActivationHistoryEntry 7 }
juniRedundancyHistoryResetReason OBJECT-TYPE
SYNTAX JuniRedundancyResetReason
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the reason for reload or switchover of the slots involved."
::= { juniRedundancySystemActivationHistoryEntry 8 }
juniRedundancyHistoryActivationTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the date and time when the reload or switchover of the slots
occurred."
::= { juniRedundancySystemActivationHistoryEntry 9 }
juniRedundancyHistoryReloads OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of reloads since the system is powered on."
::= { juniRedundancyHistory 4 }
juniRedundancyHistoryColdSwitchovers OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of cold switchovers since the system is powered on."
::= { juniRedundancyHistory 5 }
juniRedundancyHistoryWarmSwitchovers OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of warm switchovers since the system is powered on."
::= { juniRedundancyHistory 6 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Notifications
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniRedundancyColdSwitchoverNotification NOTIFICATION-TYPE
OBJECTS {
juniRedundancyActiveSlot,
juniRedundancyLastResetReason
}
STATUS current
DESCRIPTION
"This notification is generated in a dual SRP system when control
transfers from one to SRP to the other in file system synchronization
mode or when high availability is not operational. This notification
is sent by the newly active SRP immediately following the switchover
in which configuration is preserved but volatile state is lost."
::= { juniRedundancyNotifications 1 }
juniRedundancyWarmSwitchoverNotification NOTIFICATION-TYPE
OBJECTS {
juniRedundancyActiveSlot,
juniRedundancyLastResetReason
}
STATUS current
DESCRIPTION
"This notification is generated in a dual SRP system when control
transfers from one SRP to the other and high availability is
operational. This notification is sent by the newly active SRP
immediately following the switchover in which configuration and
volatile state are preserved."
::= { juniRedundancyNotifications 2 }
juniRedundancyStateEnabledNotification NOTIFICATION-TYPE
OBJECTS {
juniRedundancyActiveSlot
}
STATUS current
DESCRIPTION
"A state change notification sent by active SRP whenever system enters
'active' state."
::= { juniRedundancyNotifications 3 }
juniRedundancyStateDisabledNotification NOTIFICATION-TYPE
OBJECTS {
juniRedundancyActiveSlot
}
STATUS current
DESCRIPTION
"A state change notification sent by active SRP whenever system enters
'disabled' state."
::= { juniRedundancyNotifications 4 }
juniRedundancyStatePendingNotification NOTIFICATION-TYPE
OBJECTS {
juniRedundancyActiveSlot
}
STATUS current
DESCRIPTION
"A state change notification sent by active SRP whenever system enters
'pending' state."
::= { juniRedundancyNotifications 5 }
juniRedundancyModeNotification NOTIFICATION-TYPE
OBJECTS {
juniRedundancyActiveSlot,
juniRedundancyCfgRedundancyMode
}
STATUS current
DESCRIPTION
"A mode change notification sent by active SRP whenever redundancy mode
of the system is changed from 'fileSystemSynchronization' to 'highAvailability'
and vice versa."
::= { juniRedundancyNotifications 6 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Conformance information
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniRedundancyMIBCompliances OBJECT IDENTIFIER ::= { juniRedundancyMIBConformance 1 }
juniRedundancyMIBGroups OBJECT IDENTIFIER ::= { juniRedundancyMIBConformance 2 }
--
-- compliance statements
--
juniRedundancyMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for system redundancy support."
MODULE -- this module
MANDATORY-GROUPS {
juniRedundancyStatusGroup,
juniRedundancyCfgGroup,
juniRedundancyHistoryGroup,
juniRedundancyNotificationGroup
}
::= { juniRedundancyMIBCompliances 1 }
--
-- units of conformance
--
juniRedundancyStatusGroup OBJECT-GROUP
OBJECTS {
juniRedundancyActiveSlot,
juniRedundancyActiveSlotState,
juniRedundancyStandbySlot,
juniRedundancyStandbySlotState,
juniRedundancyLastResetReason,
juniRedundancyLastSystemActivationTime,
juniRedundancyLastSystemActivationType,
juniRedundancyHaActiveTime }
STATUS current
DESCRIPTION
"The collection of redundancy status objects."
::= { juniRedundancyMIBGroups 1 }
juniRedundancyCfgGroup OBJECT-GROUP
OBJECTS {
juniRedundancyNotifsEnabled,
juniRedundancyCfgRedundancyMode }
STATUS current
DESCRIPTION
"The collection of redundancy configuration objects."
::= { juniRedundancyMIBGroups 2 }
juniRedundancyHistoryGroup OBJECT-GROUP
OBJECTS {
juniRedundancySystemActivationHistoryTableMaxLength,
juniRedundancySystemActivationHistoryCommand,
juniRedundancyHistoryResetType,
juniRedundancyHistoryActivationType,
juniRedundancyHistoryPrevActiveSlot,
juniRedundancyHistoryPrevActiveRelease,
juniRedundancyHistoryCurrActiveSlot,
juniRedundancyHistoryCurrActiveRelease,
juniRedundancyHistoryResetReason,
juniRedundancyHistoryActivationTime,
juniRedundancyHistoryReloads,
juniRedundancyHistoryColdSwitchovers,
juniRedundancyHistoryWarmSwitchovers }
STATUS current
DESCRIPTION
"The collection of redundancy history objects."
::= { juniRedundancyMIBGroups 3 }
juniRedundancyNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
juniRedundancyColdSwitchoverNotification,
juniRedundancyWarmSwitchoverNotification,
juniRedundancyStateEnabledNotification,
juniRedundancyStateDisabledNotification,
juniRedundancyStatePendingNotification,
juniRedundancyModeNotification }
STATUS current
DESCRIPTION
"The collection of notifications for redundancy events."
::= { juniRedundancyMIBGroups 4 }
END