-- Juniper-UNI-ATM-MIB
--
-- Juniper Networks Enterprise MIB
-- ATM MIB
--
-- Copyright (c) 1999 Redstone Communications, Inc.
-- Copyright (c) 1999, 2002 Unisphere Networks, Inc.
-- Copyright (c) 2002, 2005 Juniper Networks, Inc.
-- All Rights Reserved.
-- *****************************************************************************
Juniper-UNI-ATM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32,
Unsigned32, Counter64, Counter32, IpAddress, TimeTicks
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, RowStatus, TruthValue, TimeStamp, DisplayString
FROM SNMPv2-TC
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
InterfaceIndex, InterfaceIndexOrZero, ifIndex
FROM IF-MIB
AtmVpIdentifier, AtmVcIdentifier, AtmVorXAdminStatus, AtmAddr
FROM ATM-TC-MIB
atmVplVpi, atmVclVpi, atmVclVci
FROM ATM-MIB
atmfM4VpTestObject, atmfM4VpTestId, atmfM4VpTestType, atmfM4VpTestResult,
atmfM4VcTestObject, atmfM4VcTestId, atmfM4VcTestType, atmfM4VcTestResult,
atmfM4VpTestCode, atmfM4VcTestCode
FROM ATM-FORUM-SNMP-M4-MIB
juniMibs
FROM Juniper-MIBs
JuniNextIfIndex, JuniEnable, JuniInterfaceLocationType,
JuniInterfaceLocationValue
FROM Juniper-TC;
juniAtmMIB MODULE-IDENTITY
LAST-UPDATED "200511151133Z" -- 15-Nov-05 11:33 AM EST - JUNOSe 7.3
ORGANIZATION "Juniper Networks, Inc."
CONTACT-INFO
" Juniper Networks, Inc.
Postal: 10 Technology Park Drive
Westford, MA 01886-3146
USA
Tel: +1 978 589 5800
Email: mib@Juniper.net"
DESCRIPTION
"The ATM MIB for the Juniper enterprise."
REVISION "200511151133Z" -- 15-Nov-05 11:33 AM EST - JUNOSe 7.3
DESCRIPTION
"Added ATM VC Class support"
-- Revision History
REVISION "200508171726Z" -- 17-Aug-05 01:26 PM EDT - JUNOSe 7.3
DESCRIPTION
"Removed support for:
juniAtmIfSvcSignallingTable
juniAtmIfPnniRccTable
juniAtmSubIfAddress
juniAtmSubIfSvcConfigTable."
REVISION "200502172315Z" -- 17-Feb-05 06:15 PM EST - JUNOSe 7.1
DESCRIPTION
"Added the following to juniAtmCircuitOamTable:
juniAtmCircuitInOamF5EndToEndLoopbackCmds
juniAtmCircuitInOamF5EndToEndLoopbackRsps
juniAtmCircuitInOamF5SegmentLoopbackCmds
juniAtmCircuitInOamF5SegmentLoopbackRsps
juniAtmCircuitOutOamF5EndToEndLoopbackCmds
juniAtmCircuitOutOamF5EndToEndLoopbackRsps
juniAtmCircuitOutOamF5SegmentLoopbackCmds
juniAtmCircuitOutOamF5SegmentLoopbackRsps
juniAtmCircuitOamUpCount
juniAtmCircuitOamDownCount
juniAtmCircuitOamRetryFrequency
juniAtmCircuitOamAlarmDownCount
juniAtmCircuitOamAlarmClearTimeout
Added the following to juniAtmF4FlowOamEndToEndStatsTable:
juniAtmF4FlowEndToEndInLoopbackCmds
juniAtmF4FlowEndToEndInLoopbackRsps
juniAtmF4FlowEndToEndOutLoopbackCmds
juniAtmF4FlowEndToEndOutLoopbackRsps
Added the following to juniAtmF4FlowOamSegmentStatsTable:
juniAtmF4FlowSegmentInLoopbackCmds
juniAtmF4FlowSegmentInLoopbackRsps
juniAtmF4FlowSegmentOutLoopbackCmds
juniAtmF4FlowSegmentOutLoopbackRsps"
REVISION "200412081522Z" -- 08-Dec-04 10:22 AM EST - JUNOSe 7.0
DESCRIPTION
"Added aal0 and aal5 values to juniAtmSubIfVccType enumeration.
Added ATM Martini cell aggregation configuration objects.
Added profile override support.
Added bulk-configuration modification support."
REVISION "200312301507Z" -- 25-Feb-04 03:23 PM EST - JUNOSe 6.0
DESCRIPTION
"Added second generation E-series platform support:
Imported JuniInterfaceLocationType and JuniInterfaceLocationValue
from Juniper-TC to replace JuniAtmLocationType and
JuniAtmLocationValue textual conventions, respectively."
REVISION "200402252023Z" -- 25-Feb-04 03:23 PM EST - JUNOSe 5.3
DESCRIPTION
"Added support to export the subinterface description to the line
cards. Added advisory receive support for subinterfaces."
REVISION "200309192201Z" -- 19-Sep-03 06:01 PM EDT - JUNOSe 5.2
DESCRIPTION
"Added JuniAtmLocationType and JuniAtmLocationValue textual conventions.
Added juniAtmSubIfLocationType and juniAtmSubIfLocationTable."
REVISION "200307141537Z" -- 14-Jul-03 11:37 AM EDT - JUNOSe 5.1
DESCRIPTION
"Added F4 flow OAM circuit support.
Added ATM VP description support.
Added bulk circuit configuration support.
Corrected enumeration values for UNI signalling versions."
REVISION "200301151932Z" -- 15-Jan-03 02:32 PM EST - JUNOSe 5.0
DESCRIPTION
"Replaced Unisphere names with Juniper names.
Changed the juniAtmVcPingProbeCount Range to match CLI.
Added null value for juniAtmSubIfVccType."
REVISION "200208091403Z" -- 09-Aug-02 10:03 AM EDT - JUNOSe 4.1
DESCRIPTION
"Added receive bandwith support to CAC.
Added E164 public addressing support.
Added PNNI RCC table support.
Added ATM1483 interface MTU config support."
REVISION "200208091340Z" -- 09-Aug-02 09:40 AM EDT - JUNOSe 4.0
DESCRIPTION
"Added support for CAC used bandwidth.
Added ATM switched virtual connection (SVC) support.
Added juniAtmSubIfAddress to the juniAtmSubIfTable."
REVISION "200201241400Z" -- 24-Jan-02 09:00 AM EST - JUNOSe 3.4
DESCRIPTION
"Added support for connection admission control (CAC)."
REVISION "200112141804Z" -- 14-Dec-01 01:04 PM EST - JUNOSe 3.3
DESCRIPTION
"Added support from ATM traffic shaping."
REVISION "200111261639Z" -- 26-Nov-01 11:39 AM EST - JUNOSe 3.2
DESCRIPTION
"Added support for NBMA map lists.
Added support for ATM ping.
Changed juniAtmSubIfVccVcd and juniAtmIfIlmiVcd ranges to
(0..2147483647).
Added range to juniAtmIfCapabilityMaxVcd.
Added rtVbr service catagory to juniAtmSubIfVccTable.
Added support for OAM cell filter.
Added PVC counter for reveived unknown protocol."
REVISION "200011271951Z" -- 27-Nov-00 02:51 PM EST - JUNOSe 3.0
DESCRIPTION
"Added autoconfig value for juniAtmSubIfVccType.
Added in/out summary cell counters.
Added juniVpTunnelServiceCategory to juniAtmVpTunnelTable.
Added support for atm interface capability traversal."
REVISION "200008020000Z" -- 02-Aug-00 - JUNOSe 2.3
DESCRIPTION
"Added the juniAtmCircuitOamTable."
REVISION "200005120000Z" -- 12-May-00 - JUNOSe 2.0
DESCRIPTION
"Added the juniAtmVpTunnelTable."
REVISION "200001130000Z" -- 13-Jan-00 - JUNOSe 1.3
DESCRIPTION
"Added the juniAtmPvcStatisticsTable."
REVISION "9908040000Z" -- 04-Aug-99 - JUNOSe 1.1
DESCRIPTION
"Initial version of this MIB module."
::= { juniMibs 8 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Textual conventions
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
JuniAtmNbmaMapName ::= TEXTUAL-CONVENTION
DISPLAY-HINT "32a"
STATUS current
DESCRIPTION
"An administratively assigned map name. Represents textual information
taken from the NVT ASCII character set. The name must be unique per
system."
REFERENCE
"RFC 854: NVT ASCII character set. See SNMPv2-TC.DisplayString
DESCRIPTION for a summary."
SYNTAX OCTET STRING (SIZE(1..32))
JuniAtmNbmaMapNameOrNull ::= TEXTUAL-CONVENTION
DISPLAY-HINT "32a"
STATUS current
DESCRIPTION
"An administratively assigned map name. Represents textual information
taken from the NVT ASCII character set. The name must be unique per
system.
Differs from JuniAtmNbmaMapName in that it permits a zero-length
string."
REFERENCE
"RFC 854: NVT ASCII character set. See SNMPv2-TC.DisplayString
DESCRIPTION for a summary."
SYNTAX OCTET STRING (SIZE(0..32))
JuniAtmLocationType ::= TEXTUAL-CONVENTION
STATUS obsolete
DESCRIPTION
"Obsolete description of the platform-dependent interpretation of a
JuniAtmLocationValue object. This textual convention has been relpaced
by Juniper-TC.JuniInterfaceLocationType."
SYNTAX INTEGER {
unknown(0),
slotPort(1) }
JuniAtmLocationValue ::= TEXTUAL-CONVENTION
STATUS obsolete
DESCRIPTION
"Obsolete value of a platform-dependent interface location, represented
as an OCTET STRING. A corresponding JuniAtmLocationType object
identified the mapping of octets to location elements, e.g. 'slot.port'.
This textual convention has been replaced by
Juniper-TC.JuniInterfaceLocationValue."
SYNTAX OCTET STRING (SIZE(1..16))
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Managed objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniAtmObjects OBJECT IDENTIFIER ::= { juniAtmMIB 1 }
--
-- This MIB contains managed objects for each of three interface layers: ATM;
-- AAL5; and ATM Subinterface. For each of these layers, management objects are
-- provided to query for an available interface index, and to create/delete
-- interfaces of that type. Creating/deleting these interface types using this
-- MIB has the side effect of creating/deleting corresponding entries in the
-- Interface MIB ifTable/ifXTable, and in the Juniper Enterprise Interface MIB
-- juniIfTable.
--
juniAtmIfLayer OBJECT IDENTIFIER ::= { juniAtmObjects 1 }
juniAtmAal5IfLayer OBJECT IDENTIFIER ::= { juniAtmObjects 2 }
juniAtmSubIfLayer OBJECT IDENTIFIER ::= { juniAtmObjects 3 }
juniAtmNbma OBJECT IDENTIFIER ::= { juniAtmObjects 4 }
juniAtmPing OBJECT IDENTIFIER ::= { juniAtmObjects 5 }
juniAtmLocation OBJECT IDENTIFIER ::= { juniAtmObjects 6 }
juniAtmVcClass OBJECT IDENTIFIER ::= { juniAtmObjects 7}
-- /////////////////////////////////////////////////////////////////////////////
--
-- ATM LAYER
--
-- /////////////////////////////////////////////////////////////////////////////
--
-- IfIndex selection for creating new ATM interfaces
--
juniAtmNextIfIndex OBJECT-TYPE
SYNTAX JuniNextIfIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Coordinate ifIndex value allocation for entries in juniAtmIfTable.
A GET of this object returns the next available ifIndex value to be used
to create an entry in the associated interface table; or zero, if no
valid ifIndex value is available. This object also returns a value of
zero when it is the lexicographic successor of a varbind presented in an
SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
that ifIndex allocation is unintended.
Successive GETs will typically return different values, thus avoiding
collisions among cooperating management clients seeking to create table
entries simultaneously."
::= { juniAtmIfLayer 1 }
--
-- The ATM Interface Table
--
juniAtmIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for ATM interfaces present in the system."
::= { juniAtmIfLayer 2 }
juniAtmIfEntry OBJECT-TYPE
SYNTAX JuniAtmIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describes the characteristics of an ATM interface.
Creating/deleting entries in this table causes corresponding entries for
be created/deleted in ifTable/ifXTable/juniIfTable."
INDEX { juniAtmIfIndex }
::= { juniAtmIfTable 1 }
JuniAtmIfEntry ::= SEQUENCE {
juniAtmIfIndex InterfaceIndex,
juniAtmIfRowStatus RowStatus,
juniAtmIfLowerIfIndex InterfaceIndexOrZero,
juniAtmIfIlmiVpi AtmVpIdentifier,
juniAtmIfIlmiVci AtmVcIdentifier,
juniAtmIfIlmiVcd Integer32,
juniAtmIfIlmiPollFrequency Integer32,
juniAtmIfIlmiAdminState INTEGER,
juniAtmIfUniVersion INTEGER,
juniAtmIfOamCellRxAdminState INTEGER,
juniAtmIfInCells Counter64,
juniAtmIfOutCells Counter64,
juniAtmIfVcCount Integer32,
juniAtmIfMapGroup JuniAtmNbmaMapNameOrNull,
juniAtmIfCacAdminState JuniEnable,
juniAtmIfCacUbrWeight Integer32,
juniAtmIfCacSubscriptionBandwidth Integer32,
juniAtmIfCacAvailableBandwidth Integer32,
juniAtmIfCacAvailableBandwidthRx Integer32,
juniAtmIfE164Autoconversion INTEGER,
juniAtmIfE164Gateway INTEGER,
juniAtmIfE164OneToOneAddrTrans INTEGER,
juniAtmIfOamCellFilter INTEGER,
juniAtmIfCacUsedBandwidthUpper Unsigned32,
juniAtmIfCacUsedBandwidthLower Unsigned32,
juniAtmIfAssociatedVcClassId Unsigned32 }
juniAtmIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of the ATM interface. When creating entries in this table,
suitable values for this object are determined by reading
juniAtmNextIfIndex."
::= { juniAtmIfEntry 1 }
juniAtmIfRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniAtmIfRowStatus
juniAtmIfLowerIfIndex
In addition, when creating an entry the following condition must hold:
A value for juniAtmIfIndex must have been determined previously, by
reading juniAtmNextIfIndex.
A corresponding entry in ifTable/ifXTable/juniIfTable is created or
destroyed as a result of creating/destroying an entry in this table."
::= { juniAtmIfEntry 2 }
juniAtmIfLowerIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ifIndex of an interface over which this ATM interface is to be
layered. A value of zero indicates no layering. An implementation may
choose to require that a nonzero value be configured at entry creation."
::= { juniAtmIfEntry 3 }
juniAtmIfIlmiVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The VPI of the ILMI of a major ATM interface."
DEFVAL { 0 }
::= { juniAtmIfEntry 4 }
juniAtmIfIlmiVci OBJECT-TYPE
SYNTAX AtmVcIdentifier
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The VCI of the ILMI of a major ATM interface."
DEFVAL { 16 }
::= { juniAtmIfEntry 5 }
juniAtmIfIlmiVcd OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An integer identifier for the ILMI, used in conjunction with the
command-line interface.
The value must be unique among VCs configured on the same ATM
interface."
DEFVAL { 0 }
::= { juniAtmIfEntry 6 }
juniAtmIfIlmiPollFrequency OBJECT-TYPE
SYNTAX Integer32 (0..65535)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The amount of time in seconds between successive transmissions of ILMI
messages on this interface for the purpose of detecting loss of ILMI
connectivity. The distinguished value zero disables ILMI connectivity
procedures on this interface."
::= { juniAtmIfEntry 7 }
juniAtmIfIlmiAdminState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The administrative status of ILMI in the ATM interface."
::= { juniAtmIfEntry 8 }
juniAtmIfUniVersion OBJECT-TYPE
SYNTAX INTEGER {
uniVersionAutoConfig(0),
version3Dot0(1),
version3Dot1(2),
version4Dot0(3) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Use to specify the User Network Interface (UNI) the router should use
when ILMI link auto determination is unsuccesful or ILMI is disabled."
::= { juniAtmIfEntry 9 }
juniAtmIfOamCellRxAdminState OBJECT-TYPE
SYNTAX INTEGER {
oamCellAdminStateDisabled(0),
oamCellAdminStateEnabled(1) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Use to specify the OAM Cell Receive Administrative state on this
interface."
DEFVAL { oamCellAdminStateEnabled }
::= { juniAtmIfEntry 10 }
juniAtmIfInCells OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells received on this major interface."
::= { juniAtmIfEntry 11 }
juniAtmIfOutCells OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells transmitted on this major interface."
::= { juniAtmIfEntry 12 }
juniAtmIfVcCount OBJECT-TYPE
SYNTAX Integer32 (0..268431360)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of circuits configured on this interface."
::= { juniAtmIfEntry 13 }
juniAtmIfMapGroup OBJECT-TYPE
SYNTAX JuniAtmNbmaMapNameOrNull
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The NBMA map group this interface is associated with."
DEFVAL { "" }
::= { juniAtmIfEntry 14 }
juniAtmIfCacAdminState OBJECT-TYPE
SYNTAX JuniEnable
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The administrative staus of CAC on this ATM major interface."
DEFVAL { disable }
::= { juniAtmIfEntry 15 }
juniAtmIfCacUbrWeight OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "kbps"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The bandwidth associated with every UBR and UBR with PCR connection
configured on the ATM major interface. This value is used for CAC
computation. The units are kilo-bits per second (kbps)."
DEFVAL { 0 }
::= { juniAtmIfEntry 16 }
juniAtmIfCacSubscriptionBandwidth OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "kbps"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The subscribed bandwidth of the ATM major interface. If this value is
not specified or set to 0, the effective port bandwidth is used. When a
Get operation is performed the current effective bandwidth is returned.
The units are kilo-bits per second (kbps)."
DEFVAL { 0 }
::= { juniAtmIfEntry 17 }
juniAtmIfCacAvailableBandwidth OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "kbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The available bandwidth in Tx direction of the ATM major interface. As
connections are added or deleted on the interface, this value is
updated. The units are kilo-bits per second (kbps)."
::= { juniAtmIfEntry 18 }
juniAtmIfCacAvailableBandwidthRx OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "kbps"
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The available bandwidth in Rx direction of the ATM major interface. As
connections are added or deleted on the interface, this value is
updated. The units are kilo-bits per second (kbps)."
::= { juniAtmIfEntry 19 }
juniAtmIfE164Autoconversion OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1) }
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"The status of E164 autoconversion feature in the ATM interface."
::= { juniAtmIfEntry 20 }
juniAtmIfE164Gateway OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1) }
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"The status of E164 gateway feature in the ATM interface."
::= { juniAtmIfEntry 21 }
juniAtmIfE164OneToOneAddrTrans OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1) }
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"The status of E164 one-to-one address translation feature in the ATM
interface."
::= { juniAtmIfEntry 22 }
juniAtmIfOamCellFilter OBJECT-TYPE
SYNTAX INTEGER {
oamCellFilterAll(0),
oamCellFilterAlarm(1) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of OAM cells to discard when juniAtmIfOamCellRxAdminState is
set to oamCellAdminStateDisabled. The value oamCellFilterAlarm discards
received OAM AIS and RDI cells. The value oamCellFilterAll discards all
received OAM cells. Note that when juniAtmIfOamCellRxAdminState is set
to oamCellAdminStateEnabled, this object has no effect."
DEFVAL { oamCellFilterAll }
::= { juniAtmIfEntry 23 }
juniAtmIfCacUsedBandwidthUpper OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The most significant 32 bits of the CAC used bandwidth on the ATM major
interface. The least significant 32 bits of the CAC used bandwidth are
specified by juniAtmIfCacUsedBandwidthLower."
::= { juniAtmIfEntry 24 }
juniAtmIfCacUsedBandwidthLower OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The least significant 32 bits of the CAC used bandwidth on the ATM
major interface. The most significant 32 bits of the CAC used bandwidth
are specified by juniAtmIfCacUsedBandwidthUpper."
::= { juniAtmIfEntry 25 }
juniAtmIfAssociatedVcClassId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The integer identifier of the ATM VC class associated with this ATM interface. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable. A value of 0 means no VC class association exists for this interface."
DEFVAL { 0 }
::= { juniAtmIfEntry 26 }
--
-- The ATM VPI/VCI Statistics Table
--
juniAtmPvcStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmPvcStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains statistics for PVC entries."
::= { juniAtmIfLayer 3 }
juniAtmPvcStatisticsEntry OBJECT-TYPE
SYNTAX JuniAtmPvcStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry provides statistics on an ATM PVC."
INDEX { juniAtmPvcStatsIfIndex,
juniAtmPvcStatsVpi,
juniAtmPvcStatsVci }
::= { juniAtmPvcStatisticsTable 1 }
JuniAtmPvcStatisticsEntry ::= SEQUENCE {
juniAtmPvcStatsIfIndex InterfaceIndex,
juniAtmPvcStatsVpi AtmVpIdentifier,
juniAtmPvcStatsVci AtmVcIdentifier,
juniAtmPvcStatsInCells Counter64,
juniAtmPvcStatsInCellOctets Counter64,
juniAtmPvcStatsInPackets Counter64,
juniAtmPvcStatsInPacketOctets Counter64,
juniAtmPvcStatsOutCells Counter64,
juniAtmPvcStatsOutCellOctets Counter64,
juniAtmPvcStatsOutPackets Counter64,
juniAtmPvcStatsOutPacketOctets Counter64,
juniAtmPvcStatsInCellErrors Counter32,
juniAtmPvcStatsinPacketErrors Counter32,
juniAtmPvcStatsOutCellErrors Counter32,
juniAtmPvcStatsOutPacketErrors Counter32,
juniAtmPvcStatsInPacketDiscards Counter32,
juniAtmPvcStatsInPacketOctetDiscards Counter32,
juniAtmPvcStatsInPacketUnknownProtocol Counter32 }
juniAtmPvcStatsIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of the ATM interface."
::= { juniAtmPvcStatisticsEntry 1 }
juniAtmPvcStatsVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VPI of the ATM VCC used by this ATM interface and PVC."
::= { juniAtmPvcStatisticsEntry 2 }
juniAtmPvcStatsVci OBJECT-TYPE
SYNTAX AtmVcIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VCI of the ATM VCC used by this ATM interface and PVC."
::= { juniAtmPvcStatisticsEntry 3 }
juniAtmPvcStatsInCells OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received cells."
::= { juniAtmPvcStatisticsEntry 4 }
juniAtmPvcStatsInCellOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received cells octets."
::= { juniAtmPvcStatisticsEntry 5 }
juniAtmPvcStatsInPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received AAL PDUs."
::= { juniAtmPvcStatisticsEntry 6 }
juniAtmPvcStatsInPacketOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received AAL PDU octets."
::= { juniAtmPvcStatisticsEntry 7 }
juniAtmPvcStatsOutCells OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted cells."
::= { juniAtmPvcStatisticsEntry 8 }
juniAtmPvcStatsOutCellOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted cell octets."
::= { juniAtmPvcStatisticsEntry 9 }
juniAtmPvcStatsOutPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted AAL PDUs."
::= { juniAtmPvcStatisticsEntry 10 }
juniAtmPvcStatsOutPacketOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted AAL PDU octets."
::= { juniAtmPvcStatisticsEntry 11 }
juniAtmPvcStatsInCellErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received cells dropped due to errors."
::= { juniAtmPvcStatisticsEntry 12 }
juniAtmPvcStatsinPacketErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received packets dropped due to errors."
::= { juniAtmPvcStatisticsEntry 13 }
juniAtmPvcStatsOutCellErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cells not transmitted due to errors."
::= { juniAtmPvcStatisticsEntry 14 }
juniAtmPvcStatsOutPacketErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packets not transmitted due to errors."
::= { juniAtmPvcStatisticsEntry 15 }
juniAtmPvcStatsInPacketDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received packets w/o errors discarded."
::= { juniAtmPvcStatisticsEntry 16 }
juniAtmPvcStatsInPacketOctetDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received bytes w/o errors discarded."
::= { juniAtmPvcStatisticsEntry 17 }
juniAtmPvcStatsInPacketUnknownProtocol OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received packets that are discarded because the interface can not
discern or is not configured to support this protocol."
::= { juniAtmPvcStatisticsEntry 18 }
--
-- The ATM Virtual Path Tunnel Table
--
juniAtmVpTunnelTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmVpTunnelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for ATM VP Tunnels present in the system."
::= { juniAtmIfLayer 4 }
juniAtmVpTunnelEntry OBJECT-TYPE
SYNTAX JuniAtmVpTunnelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describes the characteristics of an ATM VP Tunnel."
INDEX { juniAtmVpTunnelIfIndex,
juniAtmVpTunnelVpi }
::= { juniAtmVpTunnelTable 1 }
JuniAtmVpTunnelEntry ::= SEQUENCE {
juniAtmVpTunnelIfIndex InterfaceIndex,
juniAtmVpTunnelVpi AtmVpIdentifier,
juniAtmVpTunnelKbps Integer32,
juniAtmVpTunnelRowStatus RowStatus,
juniAtmVpTunnelServiceCategory INTEGER }
juniAtmVpTunnelIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of the ATM interface. The value of this object is the same
as the juniAtmIfIndex object in the juniAtmIfTable.
Entries in this table cannot be created unless the underlying ATM
interface entry is created first in the juniAtmIfTable."
::= { juniAtmVpTunnelEntry 1 }
juniAtmVpTunnelVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VPI value for this VP tunnel entry."
::= { juniAtmVpTunnelEntry 2 }
juniAtmVpTunnelKbps OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "kbps"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The tunnel rate in kilobits per second (kbps) for this entry."
::= { juniAtmVpTunnelEntry 3 }
juniAtmVpTunnelRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniAtmVpTunnelRowStatus
juniAtmVpTunnelKbps
In addition, when creating an entry the following condition must hold:
A correponding juniAtmVpTunnelIfIndex value must have been created
in the juniAtmIfTable previously."
::= { juniAtmVpTunnelEntry 4 }
juniAtmVpTunnelServiceCategory OBJECT-TYPE
SYNTAX INTEGER {
nrtVbr(1),
cbr(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ATM service category for the tunnel."
::= { juniAtmVpTunnelEntry 5 }
--
-- The ATM Interface Capability Table
--
juniAtmIfCapabilityTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmIfCapabilityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for ATM interfaces present in the system."
::= { juniAtmIfLayer 5 }
juniAtmIfCapabilityEntry OBJECT-TYPE
SYNTAX JuniAtmIfCapabilityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describes the capabilities of an ATM interface. A
management client can use this table to determine differences in the
configurable level of support across entries in this table."
INDEX { juniAtmIfCapabilityIndex }
::= { juniAtmIfCapabilityTable 1 }
JuniAtmIfCapabilityEntry ::= SEQUENCE {
juniAtmIfCapabilityIndex InterfaceIndex,
juniAtmIfCapabilityTrafficShaping TruthValue,
juniAtmIfCapabilityOam TruthValue,
juniAtmIfCapabilityDefaultVcPerVp Integer32,
juniAtmIfCapabilityNumVpiVciBits Integer32,
juniAtmIfCapabilityMaxVcd Integer32,
juniAtmIfCapabilityMaxVpi AtmVpIdentifier,
juniAtmIfCapabilityMaxVci AtmVcIdentifier,
juniAtmIfCapabilityOamCellFilter TruthValue }
juniAtmIfCapabilityIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of the ATM interface. The value of this object is the same
as juniAtmIfIndex in the juniAtmIfTable."
::= { juniAtmIfCapabilityEntry 1 }
juniAtmIfCapabilityTrafficShaping OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether traffic shaping is supported on this interface;
true(1) indicates that it is, false(2) indicates that it is not."
::= { juniAtmIfCapabilityEntry 2 }
juniAtmIfCapabilityOam OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether OAM is supported on this interface; true(1) indicates
that it is, false(2) indicates that it is not."
::= { juniAtmIfCapabilityEntry 3 }
juniAtmIfCapabilityDefaultVcPerVp OBJECT-TYPE
SYNTAX Integer32 (0..65536)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The default number of VCs per VP for this interface."
::= { juniAtmIfCapabilityEntry 4 }
juniAtmIfCapabilityNumVpiVciBits OBJECT-TYPE
SYNTAX Integer32 (8..28)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total range of bits used for constructing VPI/VCI identifiers for
this interface."
::= { juniAtmIfCapabilityEntry 5 }
juniAtmIfCapabilityMaxVcd OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum configurable value for a VCD on this interface."
::= { juniAtmIfCapabilityEntry 6 }
juniAtmIfCapabilityMaxVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum configurable value for a VPI on this interface."
::= { juniAtmIfCapabilityEntry 7 }
juniAtmIfCapabilityMaxVci OBJECT-TYPE
SYNTAX AtmVcIdentifier
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum configurable value for a VCI on this interface."
::= { juniAtmIfCapabilityEntry 8 }
juniAtmIfCapabilityOamCellFilter OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether OAM cell filter is supported on this interface;
true(1) indicates that it is, false(2) indicates that it is not."
::= { juniAtmIfCapabilityEntry 9 }
--
-- The juniAtmIfSvcSignallingTable extends the juniAtmIfTable for ATM switched
-- virtual connections (SVCs).
--
juniAtmIfSvcSignallingTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmIfSvcSignallingEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This table contains entries for extending the juniAtmIfTable for
configuring signalling information for switched virtual connection
(SVC)."
::= { juniAtmIfLayer 6 }
juniAtmIfSvcSignallingEntry OBJECT-TYPE
SYNTAX JuniAtmIfSvcSignallingEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Each entry provides configuration parameters for ATM signalling on the
interface."
INDEX { juniAtmIfIndex }
::= { juniAtmIfSvcSignallingTable 1 }
JuniAtmIfSvcSignallingEntry ::= SEQUENCE {
juniAtmIfSvcSignallingVpi AtmVpIdentifier,
juniAtmIfSvcSignallingVci AtmVcIdentifier,
juniAtmIfSvcSignallingVcd Integer32,
juniAtmIfSvcSignallingAdminStatus AtmVorXAdminStatus }
juniAtmIfSvcSignallingVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"The VPI identifier of the ATM circuit used for signalling for this
interface."
DEFVAL { 0 }
::= { juniAtmIfSvcSignallingEntry 1 }
juniAtmIfSvcSignallingVci OBJECT-TYPE
SYNTAX AtmVcIdentifier
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"The VCI identifier of the ATM circuit used for signalling for this
interface."
DEFVAL { 5 }
::= { juniAtmIfSvcSignallingEntry 2 }
juniAtmIfSvcSignallingVcd OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"An integer identifier for the ATM circuit used for signalling on this
interface."
DEFVAL { 0 }
::= { juniAtmIfSvcSignallingEntry 3 }
juniAtmIfSvcSignallingAdminStatus OBJECT-TYPE
SYNTAX AtmVorXAdminStatus
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"The administrative status of signalling on the ATM interface."
::= { juniAtmIfSvcSignallingEntry 4 }
--
-- The juniAtmIfPnniRccTable extends the juniAtmIfTable for PNNI Routing
-- Control Channel
--
juniAtmIfPnniRccTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmIfPnniRccEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"This table contains entries for extending the juniAtmIfTable for
configuring PNNI RCC information."
::= { juniAtmIfLayer 7 }
juniAtmIfPnniRccEntry OBJECT-TYPE
SYNTAX JuniAtmIfPnniRccEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Each entry provides configuration parameters for PNNI RCC on the
interface."
INDEX { juniAtmIfIndex }
::= { juniAtmIfPnniRccTable 1 }
JuniAtmIfPnniRccEntry ::= SEQUENCE {
juniAtmIfPnniRccVpi AtmVpIdentifier,
juniAtmIfPnniRccVci AtmVcIdentifier,
juniAtmIfPnniRccVcd Integer32,
juniAtmIfPnniRccAdminStatus AtmVorXAdminStatus }
juniAtmIfPnniRccVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"The VPI identifier of the ATM circuit used for PNNI RCC on this
interface."
DEFVAL { 0 }
::= { juniAtmIfPnniRccEntry 1 }
juniAtmIfPnniRccVci OBJECT-TYPE
SYNTAX AtmVcIdentifier
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"The VCI identifier of the ATM circuit used for PNNI RCC on this
interface."
DEFVAL { 18 }
::= { juniAtmIfPnniRccEntry 2 }
juniAtmIfPnniRccVcd OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"An integer identifier for the ATM circuit used for PNNI RCC on this
interface."
DEFVAL { 0 }
::= { juniAtmIfPnniRccEntry 3 }
juniAtmIfPnniRccAdminStatus OBJECT-TYPE
SYNTAX AtmVorXAdminStatus
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"The administrative status of PNNI on the ATM interface."
::= { juniAtmIfPnniRccEntry 4 }
--
-- The juniAtmOamF4FlowEndToEndConfigTable
--
juniAtmOamF4FlowEndToEndCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmOamF4FlowEndToEndCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for F4 OAM end-to-end flows configured."
::= { juniAtmIfLayer 8 }
juniAtmOamF4FlowEndToEndCfgEntry OBJECT-TYPE
SYNTAX JuniAtmOamF4FlowEndToEndCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry provides configuration parameters for one F4 OAM end-to-end
flow configured for each VPI."
INDEX { juniAtmOamF4FlowEndToEndIfIndex,
juniAtmOamF4FlowEndToEndVpi }
::= { juniAtmOamF4FlowEndToEndCfgTable 1 }
JuniAtmOamF4FlowEndToEndCfgEntry ::= SEQUENCE {
juniAtmOamF4FlowEndToEndIfIndex InterfaceIndex,
juniAtmOamF4FlowEndToEndVpi Integer32,
juniAtmOamF4FlowEndToEndLoopbackTimer Integer32,
juniAtmOamF4FlowEndToEndCCSink TruthValue,
juniAtmOamF4FlowEndToEndCCSource TruthValue,
juniAtmOamF4FlowEndToEndRowStatus RowStatus }
juniAtmOamF4FlowEndToEndIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of the ATM interface to configure the F4 OAM end-to-end
flow."
::= { juniAtmOamF4FlowEndToEndCfgEntry 1 }
juniAtmOamF4FlowEndToEndVpi OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Select the VPI for F4 OAM end-to-end flow configuration."
::= { juniAtmOamF4FlowEndToEndCfgEntry 2 }
juniAtmOamF4FlowEndToEndLoopbackTimer OBJECT-TYPE
SYNTAX Integer32 (-1..600)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Configure the timer for sending the F4 flow end-to-end loopback OAM
cells. Setting this value will enable sending the F4 end cells on the
circuit. It is not allowed to set the value to -1 and whenever it is
read as -1 that means sending end loopback is not enabled. Setting the
loopback timer, other than -1, will enable sending the end cells."
DEFVAL { -1 }
::= { juniAtmOamF4FlowEndToEndCfgEntry 3 }
juniAtmOamF4FlowEndToEndCCSink OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/Disable F4 flow end-to-end continuity check sink end point for
this VP."
DEFVAL { false }
::= { juniAtmOamF4FlowEndToEndCfgEntry 4 }
juniAtmOamF4FlowEndToEndCCSource OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/Disable F4 flow end-to-end continuity check source end point for
this VP."
DEFVAL { false }
::= { juniAtmOamF4FlowEndToEndCfgEntry 5 }
juniAtmOamF4FlowEndToEndRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create/delete an entry in this table, the following entry objects
MUST be explicitly configured:
juniAtmOamF4FlowEndToEndRowStatus
F4 OAM end loopback and CC tests are mutually exclusive, enabling one
will disable the other automatically. So, it is not allowed either at
the circuit creation time or after the circuit creation to issue a
request to enable end-to-end loopback and CC tests simultaneouly.
Enabling/disabling CC sink and source is one time operation. To
re-enable either CC source and sink in way different to earlier, both
has to be disabled from the previous."
::= { juniAtmOamF4FlowEndToEndCfgEntry 6 }
--
-- The juniAtmOamF4FlowSegmentConfigTable
--
juniAtmOamF4FlowSegmentCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmOamF4FlowSegmentCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for F4 OAM Segment flows configured."
::= { juniAtmIfLayer 9 }
juniAtmOamF4FlowSegmentCfgEntry OBJECT-TYPE
SYNTAX JuniAtmOamF4FlowSegmentCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry provides configuration parameters for one F4 OAM Segment
flow configured for each VPI."
INDEX { juniAtmOamF4FlowSegmentIfIndex,
juniAtmOamF4FlowSegmentVpi }
::= { juniAtmOamF4FlowSegmentCfgTable 1 }
JuniAtmOamF4FlowSegmentCfgEntry ::= SEQUENCE {
juniAtmOamF4FlowSegmentIfIndex InterfaceIndex,
juniAtmOamF4FlowSegmentVpi Integer32,
juniAtmOamF4FlowSegmentCCSink TruthValue,
juniAtmOamF4FlowSegmentCCSource TruthValue,
juniAtmOamF4FlowSegmentRowStatus RowStatus }
juniAtmOamF4FlowSegmentIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of the ATM interface to configure the F4 OAM segment flow."
::= { juniAtmOamF4FlowSegmentCfgEntry 1 }
juniAtmOamF4FlowSegmentVpi OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Select the VPI for F4 OAM segment flow configuration."
::= { juniAtmOamF4FlowSegmentCfgEntry 2 }
juniAtmOamF4FlowSegmentCCSink OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/Disable F4 flow segment continuity check sink end point for
this VP."
DEFVAL { false }
::= { juniAtmOamF4FlowSegmentCfgEntry 3 }
juniAtmOamF4FlowSegmentCCSource OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/Disable F4 flow segment continuity check source end point for
this VP."
DEFVAL { false }
::= { juniAtmOamF4FlowSegmentCfgEntry 4 }
juniAtmOamF4FlowSegmentRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create/delete an entry in this table, the following entry objects
MUST be explicitly configured:
juniAtmOamF4FlowSegmentRowStatus
Enabling/disabling CC sink and source is one time operation. To
re-enable either CC source and sink in way different to earlier, both
has to be disabled from the previous. F4 OAM segment loopback test is
not supported."
::= { juniAtmOamF4FlowSegmentCfgEntry 5 }
--
-- juniAtmVpDescrTable
--
juniAtmVpDescrTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmVpDescrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for ATM VP Description present in the
system. The user can configure a description of up to 32 characters for
every VP in the ATM interface. A row exists for every VP on the ATM
interface. These rows get created as soon as the ATM major interface
created."
::= { juniAtmIfLayer 10 }
juniAtmVpDescrEntry OBJECT-TYPE
SYNTAX JuniAtmVpDescrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry contains the description of the VP."
INDEX { ifIndex,
atmVplVpi }
::= { juniAtmVpDescrTable 1 }
JuniAtmVpDescrEntry ::= SEQUENCE {
juniAtmVpDescription SnmpAdminString }
juniAtmVpDescription OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The description for this VP. The default value of this object is null
string."
DEFVAL { "" }
::= { juniAtmVpDescrEntry 1 }
--
-- The juniAtmF4FlowOamEndToEndStatsTable
--
juniAtmF4FlowOamEndToEndStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmF4FlowOamEndToEndStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for F4 flow EndToEnd OAM circuits stats."
::= { juniAtmIfLayer 11 }
juniAtmF4FlowOamEndToEndStatsEntry OBJECT-TYPE
SYNTAX JuniAtmF4FlowOamEndToEndStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry provides stats for one F4 OAM circuit for each VPI."
INDEX { juniAtmOamF4FlowEndToEndIfIndex,
juniAtmOamF4FlowEndToEndVpi }
::= { juniAtmF4FlowOamEndToEndStatsTable 1 }
JuniAtmF4FlowOamEndToEndStatsEntry ::= SEQUENCE {
juniAtmF4FlowInOamEndAisCells Counter32,
juniAtmF4FlowInOamEndRdiCells Counter32,
juniAtmF4FlowInOamEndCCCells Counter32,
juniAtmF4FlowInOamEndCCActDeActCells Counter32,
juniAtmF4FlowInOamEndLoopbackCells Counter32,
juniAtmF4FlowOutEndRdiCells Counter32,
juniAtmF4FlowOutEndCCCells Counter32,
juniAtmF4FlowOutEndCCActDeActCells Counter32,
juniAtmF4FlowOutEndToEndLoopbackCells Counter32,
juniAtmF4FlowEndActualLoopbackFreq Integer32,
juniAtmF4FlowEndLastTimeChanged TimeTicks,
juniAtmF4FlowOamEndVpOperationState INTEGER,
juniAtmF4FlowOamEndVpAdminState INTEGER,
juniAtmF4FlowEndInOamCells Counter32,
juniAtmF4FlowEndOutOamCells Counter32,
juniAtmF4FlowEndInOamCellsDropped Counter32,
juniAtmF4FlowEndToEndInLoopbackCmds Counter32,
juniAtmF4FlowEndToEndInLoopbackRsps Counter32,
juniAtmF4FlowEndToEndOutLoopbackCmds Counter32,
juniAtmF4FlowEndToEndOutLoopbackRsps Counter32 }
juniAtmF4FlowInOamEndAisCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received end-to-end OAM F4 AIS cells."
::= { juniAtmF4FlowOamEndToEndStatsEntry 1 }
juniAtmF4FlowInOamEndRdiCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received end-to-end OAM F4 RDI cells."
::= { juniAtmF4FlowOamEndToEndStatsEntry 2 }
juniAtmF4FlowInOamEndCCCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received end-to-end OAM F4 CC cells."
::= { juniAtmF4FlowOamEndToEndStatsEntry 3 }
juniAtmF4FlowInOamEndCCActDeActCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received end-to-end OAM F4 activation/de-activation cells."
::= { juniAtmF4FlowOamEndToEndStatsEntry 4 }
juniAtmF4FlowInOamEndLoopbackCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total received OAM F4 end-to-end loopback cells. Aggregate of
juniAtmF4FlowEndToEndInLoopbackCmds and
juniAtmF4FlowEndToEndInLoopbackRsps"
::= { juniAtmF4FlowOamEndToEndStatsEntry 5 }
juniAtmF4FlowOutEndRdiCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted end-to-end OAM F4 RDI cells."
::= { juniAtmF4FlowOamEndToEndStatsEntry 6 }
juniAtmF4FlowOutEndCCCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted end-to-end OAM F4 CC cells."
::= { juniAtmF4FlowOamEndToEndStatsEntry 7 }
juniAtmF4FlowOutEndCCActDeActCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted end-to-end OAM F4 activation/de-activation cells."
::= { juniAtmF4FlowOamEndToEndStatsEntry 8 }
juniAtmF4FlowOutEndToEndLoopbackCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total transmitted OAM F4 end-to-end loopback cells. Aggregate of
juniAtmF4FlowEndToEndOutLoopbackCmds and
juniAtmF4FlowEndToEndOutLoopbackRsps"
::= { juniAtmF4FlowOamEndToEndStatsEntry 9 }
juniAtmF4FlowEndActualLoopbackFreq OBJECT-TYPE
SYNTAX Integer32 (0..65535)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual end-to-end loopback Frequecy calculated for OAM cells
transmission."
::= { juniAtmF4FlowOamEndToEndStatsEntry 10 }
juniAtmF4FlowEndLastTimeChanged OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last time end-to-end F4 OAM flow got changed."
::= { juniAtmF4FlowOamEndToEndStatsEntry 11 }
juniAtmF4FlowOamEndVpOperationState OBJECT-TYPE
SYNTAX INTEGER {
vcAisState(0),
vcRdiState(1),
vcDownRetry(2),
vcUpRetry(3),
vcUp(4),
vcDown(5),
vcNotManaged(6),
vpAisState(7),
vpRdiState(8),
vcInVpRdiState(9),
vcInVpAisState(10),
vcSegmentAisState(11),
vcSegRdiState(12) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Represents the F4 end-to-end OAM flow VP operation states. It can take
one of the following operational state values:
vcAisState - AIS cell received or underlying physical layer
reporting transmission path AIS.
vcRdiState - RDI cell received.
vcDownRetry - OAM loopback failed, using retry frequency to
verify that the VC is really down.
vcUpRetry - OAM loopback successful, using retry frequency
to verify that the VC is really up.
vcUp - OAM loopback successful after up retry
verification.
vcDown - OAM loopback failed after down retry
verification.
vcNotManaged - No verification via loopback cells being
performed.
vpAisState - State when F4 AIS cell is received.
vpRdiState - State when F4 RDI cell is received.
vcInVpRdiState - The data vc is down as a result of VP failure
thorugh F4 Rdi oam cell.
vcInVpAisState - The data vc is down as a result of VP failure
through F4 Ais oam cell.
vcSegmentAisState - Segment AIS cell received.
vcSegRdiState - Segment RDI cell received."
::= { juniAtmF4FlowOamEndToEndStatsEntry 12 }
juniAtmF4FlowOamEndVpAdminState OBJECT-TYPE
SYNTAX INTEGER {
down(0),
up(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"End-to-end VP admin state."
::= { juniAtmF4FlowOamEndToEndStatsEntry 13 }
juniAtmF4FlowEndInOamCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received end-to-end OAM F4 loopback cells."
::= { juniAtmF4FlowOamEndToEndStatsEntry 14 }
juniAtmF4FlowEndOutOamCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted end-to-end OAM F4 loopback cells."
::= { juniAtmF4FlowOamEndToEndStatsEntry 15 }
juniAtmF4FlowEndInOamCellsDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received end-to-end OAM cells that were dropped."
::= { juniAtmF4FlowOamEndToEndStatsEntry 16 }
juniAtmF4FlowEndToEndInLoopbackCmds OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received OAM F4 end-to-end loopback commands."
::= { juniAtmF4FlowOamEndToEndStatsEntry 17 }
juniAtmF4FlowEndToEndInLoopbackRsps OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received OAM F4 end-to-end loopback responses."
::= { juniAtmF4FlowOamEndToEndStatsEntry 18 }
juniAtmF4FlowEndToEndOutLoopbackCmds OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted OAM F4 end-to-end loopback commands."
::= { juniAtmF4FlowOamEndToEndStatsEntry 19 }
juniAtmF4FlowEndToEndOutLoopbackRsps OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted OAM F4 end-to-end loopback responses."
::= { juniAtmF4FlowOamEndToEndStatsEntry 20 }
--
-- The juniAtmF4FlowOamSegmentStatsTable
--
juniAtmF4FlowOamSegmentStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmF4FlowOamSegmentStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for F4 flow Segment OAM circuits stats."
::= { juniAtmIfLayer 12 }
juniAtmF4FlowOamSegmentStatsEntry OBJECT-TYPE
SYNTAX JuniAtmF4FlowOamSegmentStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry provides stats for one F4 OAM circuit for each VPI."
INDEX { juniAtmOamF4FlowSegmentIfIndex,
juniAtmOamF4FlowSegmentVpi }
::= { juniAtmF4FlowOamSegmentStatsTable 1 }
JuniAtmF4FlowOamSegmentStatsEntry ::= SEQUENCE {
juniAtmF4FlowInOamSegmentAisCells Counter32,
juniAtmF4FlowInOamSegmentRdiCells Counter32,
juniAtmF4FlowInOamSegmentCCCells Counter32,
juniAtmF4FlowInOamSegmentCCActDeActCells Counter32,
juniAtmF4FlowInOamSegmentLoopbackCells Counter32,
juniAtmF4FlowOutSegmentRdiCells Counter32,
juniAtmF4FlowOutSegmentCCCells Counter32,
juniAtmF4FlowOutSegmentCCActDeActCells Counter32,
juniAtmF4FlowOutSegmentLoopbackCells Counter32,
juniAtmF4FlowSegmentLastTimeChanged TimeTicks,
juniAtmF4FlowOamSegmentVpOperationState INTEGER,
juniAtmF4FlowOamSegmentVpAdminState INTEGER,
juniAtmF4FlowSegmentInOamCells Counter32,
juniAtmF4FlowSegmentOutOamCells Counter32,
juniAtmF4FlowSegmentInOamCellsDropped Counter32,
juniAtmF4FlowSegmentInLoopbackCmds Counter32,
juniAtmF4FlowSegmentInLoopbackRsps Counter32,
juniAtmF4FlowSegmentOutLoopbackCmds Counter32,
juniAtmF4FlowSegmentOutLoopbackRsps Counter32 }
juniAtmF4FlowInOamSegmentAisCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received end-to-end OAM F4 AIS cells."
::= { juniAtmF4FlowOamSegmentStatsEntry 1 }
juniAtmF4FlowInOamSegmentRdiCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received end-to-end OAM F4 RDI cells."
::= { juniAtmF4FlowOamSegmentStatsEntry 2 }
juniAtmF4FlowInOamSegmentCCCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received end-to-end OAM F4 CC cells."
::= { juniAtmF4FlowOamSegmentStatsEntry 3 }
juniAtmF4FlowInOamSegmentCCActDeActCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received end-to-end OAM F4 activation/de-activation cells."
::= { juniAtmF4FlowOamSegmentStatsEntry 4 }
juniAtmF4FlowInOamSegmentLoopbackCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total received OAM F4 segment loopback cells. Aggregate of
juniAtmF4FlowSegmentInLoopbackCmds and
juniAtmF4FlowSegmentInLoopbackRsps"
::= { juniAtmF4FlowOamSegmentStatsEntry 5 }
juniAtmF4FlowOutSegmentRdiCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted end-to-end OAM F4 RDI cells."
::= { juniAtmF4FlowOamSegmentStatsEntry 6 }
juniAtmF4FlowOutSegmentCCCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted end-to-end OAM F4 CC cells."
::= { juniAtmF4FlowOamSegmentStatsEntry 7 }
juniAtmF4FlowOutSegmentCCActDeActCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted end-to-end OAM F4 activation/de-activation cells."
::= { juniAtmF4FlowOamSegmentStatsEntry 8 }
juniAtmF4FlowOutSegmentLoopbackCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total transmitted OAM F4 segment loopback cells. Aggregate of
juniAtmF4FlowSegmentOutLoopbackCmds and
juniAtmF4FlowSegmentOutLoopbackRsps"
::= { juniAtmF4FlowOamSegmentStatsEntry 9 }
juniAtmF4FlowSegmentLastTimeChanged OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last time end-to-end F4 OAM flow got changed."
::= { juniAtmF4FlowOamSegmentStatsEntry 10 }
juniAtmF4FlowOamSegmentVpOperationState OBJECT-TYPE
SYNTAX INTEGER {
vcAisState(0),
vcRdiState(1),
vcDownRetry(2),
vcUpRetry(3),
vcUp(4),
vcDown(5),
vcNotManaged(6),
vpAisState(7),
vpRdiState(8),
vcInVpRdiState(9),
vcInVpAisState(10),
vcSegmentAisState(11),
vcSegRdiState(12) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Represents the F4 end-to-end OAM flow VP operation states. It can take
one of the following operational state values:
vcAisState - AIS cell received or underlying physical layer
reporting transmission path AIS.
vcRdiState - RDI cell received.
vcDownRetry - OAM loopback failed, using retry frequency to
verify that the VC is really down.
vcUpRetry - OAM loopback successful, using retry frequency
to verify that the VC is really up.
vcUp - OAM loopback successful after up retry
verification.
vcDown - OAM loopback failed after down retry
verification.
vcNotManaged - No verification via loopback cells being
performed.
vpAisState - State when F4 AIS cell is received.
vpRdiState - State when F4 RDI cell is received.
vcInVpRdiState - The data vc is down as a result of VP failure
thorugh F4 Rdi oam cell.
vcInVpAisState - The data vc is down as a result of VP failure
through F4 Ais oam cell.
vcSegmentAisState - Segment AIS cell received.
vcSegRdiState - Segment RDI cell received."
::= { juniAtmF4FlowOamSegmentStatsEntry 11 }
juniAtmF4FlowOamSegmentVpAdminState OBJECT-TYPE
SYNTAX INTEGER {
down(0),
up(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Segment VP admin state."
::= { juniAtmF4FlowOamSegmentStatsEntry 12 }
juniAtmF4FlowSegmentInOamCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received end-to-end OAM F4 loopback cells."
::= { juniAtmF4FlowOamSegmentStatsEntry 13 }
juniAtmF4FlowSegmentOutOamCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted end-to-end OAM F4 loopback cells."
::= { juniAtmF4FlowOamSegmentStatsEntry 14 }
juniAtmF4FlowSegmentInOamCellsDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received end-to-end OAM cells that were dropped."
::= { juniAtmF4FlowOamSegmentStatsEntry 15 }
juniAtmF4FlowSegmentInLoopbackCmds OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received OAM F4 segment loopback commands."
::= { juniAtmF4FlowOamSegmentStatsEntry 16 }
juniAtmF4FlowSegmentInLoopbackRsps OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received OAM F4 segment loopback responses."
::= { juniAtmF4FlowOamSegmentStatsEntry 17 }
juniAtmF4FlowSegmentOutLoopbackCmds OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted OAM F4 segment loopback commands."
::= { juniAtmF4FlowOamSegmentStatsEntry 18 }
juniAtmF4FlowSegmentOutLoopbackRsps OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted OAM F4 segment loopback responses."
::= { juniAtmF4FlowOamSegmentStatsEntry 19 }
--
-- juniAtmMartiniTimeoutTimerTable
--
juniAtmMartiniTimeoutTimerTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmMartiniTimeoutTimerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for ATM Martini cell aggregation timeout
detection. The user can configure timeout values for three timers.
A row exists for every separate timer supported. These rows get
created as soon as the ERX system comes up."
::= { juniAtmIfLayer 13 }
juniAtmMartiniTimeoutTimerEntry OBJECT-TYPE
SYNTAX JuniAtmMartiniTimeoutTimerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry contains the timeout value of ATM Martini
cell aggregation timer."
INDEX { juniAtmMartiniTimeoutTimerIndex }
::= { juniAtmMartiniTimeoutTimerTable 1 }
JuniAtmMartiniTimeoutTimerEntry ::= SEQUENCE {
juniAtmMartiniTimeoutTimerIndex INTEGER,
juniAtmMartiniTimeoutTimerValue Integer32 }
juniAtmMartiniTimeoutTimerIndex OBJECT-TYPE
SYNTAX INTEGER {
timer1(1),
timer2(2),
timer3(3) }
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM Martini cell aggregation timeout timer identifier."
::= { juniAtmMartiniTimeoutTimerEntry 1 }
juniAtmMartiniTimeoutTimerValue OBJECT-TYPE
SYNTAX Integer32 (100..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ATM Martini cell aggregation timeout timer value in microseconds."
DEFVAL { 100 }
::= { juniAtmMartiniTimeoutTimerEntry 2 }
-- ///////////////////
-- ATM VP Statistics
--
-- //////////////////
--
-- juniAtmVpStatsTable
--
juniAtmVpStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmVpStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for ATM VP statistics present in the
system. A row exists for every VP on the ATM
interface. These rows get created as soon as the ATM major interface
created."
::= { juniAtmIfLayer 14 }
juniAtmVpStatsEntry OBJECT-TYPE
SYNTAX JuniAtmVpStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry contain the VP statistics."
INDEX { ifIndex,
atmVplVpi }
::= { juniAtmVpStatsTable 1 }
JuniAtmVpStatsEntry ::= SEQUENCE {
juniAtmVpStatsIfIndex InterfaceIndex,
juniAtmVpStatsVpi AtmVpIdentifier,
juniAtmVpStatsInCells Counter64,
juniAtmVpStatsInPackets Counter64,
juniAtmVpStatsInPacketOctets Counter64,
juniAtmVpStatsOutCells Counter64,
juniAtmVpStatsOutPackets Counter64,
juniAtmVpStatsOutPacketOctets Counter64,
juniAtmVpStatsInPacketErrors Counter32,
juniAtmVpStatsOutPacketErrors Counter32,
juniAtmVpStatsInPacketDiscards Counter32,
juniAtmVpStatsInPacketOctetDiscards Counter32,
juniAtmVpStatsInPacketUnknownProtocol Counter32,
juniAtmVpStatsCrcErrors Counter32,
juniAtmVpStatsSarTimeouts Counter32,
juniAtmVpStatsOverSizedPackets Counter32
}
juniAtmVpStatsIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of the ATM interface."
::= { juniAtmVpStatsEntry 1 }
juniAtmVpStatsVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VPI value of the virtual path for which statistics are retrieved."
::= { juniAtmVpStatsEntry 2 }
juniAtmVpStatsInCells OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received cells."
::= { juniAtmVpStatsEntry 3 }
juniAtmVpStatsInPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received AAL5 PDUs."
::= { juniAtmVpStatsEntry 4 }
juniAtmVpStatsInPacketOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received AAL5 PDU octets."
::= { juniAtmVpStatsEntry 5 }
juniAtmVpStatsOutCells OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted cells."
::= { juniAtmVpStatsEntry 6 }
juniAtmVpStatsOutPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted AAL5 PDUs"
::= { juniAtmVpStatsEntry 7 }
juniAtmVpStatsOutPacketOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted AAL5 PDU octets."
::= { juniAtmVpStatsEntry 8 }
juniAtmVpStatsInPacketErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received packets dropped due to errors."
::= { juniAtmVpStatsEntry 9 }
juniAtmVpStatsOutPacketErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packets not transmitted due to errors."
::= { juniAtmVpStatsEntry 10 }
juniAtmVpStatsInPacketDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received packets without errors discarded."
::= { juniAtmVpStatsEntry 11 }
juniAtmVpStatsInPacketOctetDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received bytes without errors discarded."
::= { juniAtmVpStatsEntry 12 }
juniAtmVpStatsInPacketUnknownProtocol OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received packets that are discarded because the interface can not
discern or is not configured to support this protocol."
::= { juniAtmVpStatsEntry 13 }
juniAtmVpStatsCrcErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received packets that are discarded because of check sum erros"
::= { juniAtmVpStatsEntry 14 }
juniAtmVpStatsSarTimeouts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received packets that are discarded because of SAR timeout"
::= { juniAtmVpStatsEntry 15 }
juniAtmVpStatsOverSizedPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Over sized packets that are received on this VP."
::= { juniAtmVpStatsEntry 16 }
-- /////////////////////////////////////////////////////////////////////////////
--
-- AAL5 LAYER
--
-- /////////////////////////////////////////////////////////////////////////////
--
-- IfIndex selection for creating new ATM AAL5 interfaces
--
juniAtmAal5NextIfIndex OBJECT-TYPE
SYNTAX JuniNextIfIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Coordinate ifIndex value allocation for entries in juniAtmAal5IfTable.
A GET of this object returns the next available ifIndex value to be used
to create an entry in the associated interface table; or zero, if no
valid ifIndex value is available. This object also returns a value of
zero when it is the lexicographic successor of a varbind presented in an
SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
that ifIndex allocation is unintended.
Successive GETs will typically return different values, thus avoiding
collisions among cooperating management clients seeking to create table
entries simultaneously."
::= { juniAtmAal5IfLayer 1 }
--
-- The ATM AAL5 Interface Table
--
juniAtmAal5IfTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmAal5IfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for ATM AAL5 interfaces present in the
system."
::= { juniAtmAal5IfLayer 2 }
juniAtmAal5IfEntry OBJECT-TYPE
SYNTAX JuniAtmAal5IfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describes the characteristics of an ATM AAL5 interface.
Creating/deleting entries in this table causes corresponding entries for
be created/deleted in ifTable/ifXTable/juniIfTable."
INDEX { juniAtmAal5IfIndex }
::= { juniAtmAal5IfTable 1 }
JuniAtmAal5IfEntry ::= SEQUENCE {
juniAtmAal5IfIndex InterfaceIndex,
juniAtmAal5IfRowStatus RowStatus,
juniAtmAal5IfLowerIfIndex InterfaceIndexOrZero }
juniAtmAal5IfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of the ATM AAL5 interface. When creating entries in this
table, suitable values for this object are determined by reading
juniAtmAal5NextIfIndex."
::= { juniAtmAal5IfEntry 1 }
juniAtmAal5IfRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniAtmAal5IfRowStatus
juniAtmAal5IfLowerIfIndex
In addition, when creating an entry the following condition must hold:
A value for juniAtmAal5IfIndex must have been determined previously,
by reading juniAtmAal5NextIfIndex.
A corresponding entry in ifTable/ifXTable/juniIfTable is created or
destroyed as a result of creating/destroying an entry in this table."
::= { juniAtmAal5IfEntry 2 }
juniAtmAal5IfLowerIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ifIndex of an ATM interface over which this ATM AAL5 interface is
to be layered. A value of zero indicates no layering. An
implementation may choose to require that a nonzero value be configured
at entry creation."
::= { juniAtmAal5IfEntry 3 }
--
-- ATM Bulk Circuites Name Table
--
juniAtmBulkCircuitsNameTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmBulkCircuitsNameEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entries in this table provide mappings of ATM bulk virtual circuit
range names to local integer identifiers for those profiles. These
integers are used as indexes into other MIB tables containing profile
configuration parameters associated with the same profile name."
::= { juniAtmAal5IfLayer 3 }
juniAtmBulkCircuitsNameEntry OBJECT-TYPE
SYNTAX JuniAtmBulkCircuitsNameEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A mapping of a ATM bulk virtual circuit range name to an integer
identifier for that name."
INDEX { juniAtmBulkCircuitsNameAal5IfIndex,
juniAtmBulkCircuitsNameName }
::= { juniAtmBulkCircuitsNameTable 1 }
JuniAtmBulkCircuitsNameEntry ::= SEQUENCE {
juniAtmBulkCircuitsNameAal5IfIndex InterfaceIndex,
juniAtmBulkCircuitsNameName DisplayString,
juniAtmBulkCircuitsNameRowStatus RowStatus,
juniAtmBulkCircuitsNameId Unsigned32 }
juniAtmBulkCircuitsNameAal5IfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of the ATM AAL5 interface."
::= { juniAtmBulkCircuitsNameEntry 1 }
juniAtmBulkCircuitsNameName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..80))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM bulk virtual circuit range name uniquely identifying this
entry."
::= { juniAtmBulkCircuitsNameEntry 2 }
juniAtmBulkCircuitsNameRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table. Only the values
'createAndGo' and 'destroy' may be SET.
Creating an entry in this table creates corresponding entry in
juniAtmBulkCircuitsIdTable. Deleting an entry in this table deletes
corresponding entries in juniAtmBulkCircuitsIdTable,
juniAtmBulkCircuitsTable and
juniAtmProfileOverrideAssignIfCircuitTable."
::= { juniAtmBulkCircuitsNameEntry 3 }
juniAtmBulkCircuitsNameId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The integer identifier associated with this ATM bulk virtual circuit
range name.
This value of this identifier is assigned by the device when an entry in
this table is created."
::= { juniAtmBulkCircuitsNameEntry 4 }
--
-- ATM Bulk Circuits ID Table
--
juniAtmBulkCircuitsIdTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmBulkCircuitsIdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Provides inverse mapping of ATM bulk virtual circuit IDs to ATM bulk
virtual circuit names."
::= { juniAtmAal5IfLayer 4 }
juniAtmBulkCircuitsIdEntry OBJECT-TYPE
SYNTAX JuniAtmBulkCircuitsIdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A mapping of an integer identifier to a ATM bulk virtual circuit name."
INDEX { juniAtmBulkCircuitsIdAal5IfIndex,
juniAtmBulkCircuitsIdId }
::= { juniAtmBulkCircuitsIdTable 1 }
JuniAtmBulkCircuitsIdEntry ::= SEQUENCE {
juniAtmBulkCircuitsIdAal5IfIndex InterfaceIndex,
juniAtmBulkCircuitsIdId Unsigned32,
juniAtmBulkCircuitsIdName DisplayString,
juniAtmBulkCircuitsIdNextInstance Unsigned32 }
juniAtmBulkCircuitsIdAal5IfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of the ATM AAL5 interface."
::= { juniAtmBulkCircuitsIdEntry 1 }
juniAtmBulkCircuitsIdId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The integer identifier associated with this ATM bulk virtual circuit
name."
::= { juniAtmBulkCircuitsIdEntry 2 }
juniAtmBulkCircuitsIdName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ATM bulk virtual circuit name having the associated identifier."
::= { juniAtmBulkCircuitsIdEntry 3 }
juniAtmBulkCircuitsIdNextInstance OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The next available instance value for juniAtmBulkCircuitsEntry."
::= { juniAtmBulkCircuitsIdEntry 4 }
--
-- ATM Bulk Circuits Table
--
juniAtmBulkCircuitsTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmBulkCircuitsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains bulk virtual circuit range parameters."
::= { juniAtmAal5IfLayer 5 }
juniAtmBulkCircuitsEntry OBJECT-TYPE
SYNTAX JuniAtmBulkCircuitsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describes the characteristics of VC range."
INDEX { juniAtmBulkCircuitsAal5IfIndex,
juniAtmBulkCircuitsId,
juniAtmBulkCircuitsInstance }
::= { juniAtmBulkCircuitsTable 1 }
JuniAtmBulkCircuitsEntry ::= SEQUENCE {
juniAtmBulkCircuitsAal5IfIndex InterfaceIndex,
juniAtmBulkCircuitsId Unsigned32,
juniAtmBulkCircuitsInstance Unsigned32,
juniAtmBulkCircuitsRowStatus RowStatus,
juniAtmBulkCircuitsMinVpi AtmVpIdentifier,
juniAtmBulkCircuitsMaxVpi AtmVpIdentifier,
juniAtmBulkCircuitsMinVci AtmVcIdentifier,
juniAtmBulkCircuitsMaxVci AtmVcIdentifier,
juniAtmBulkCircuitsAdminState JuniEnable }
juniAtmBulkCircuitsAal5IfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of the ATM AAL5 interface on which this bulk virtual
circuit sub-range is created."
::= { juniAtmBulkCircuitsEntry 1 }
juniAtmBulkCircuitsId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The integer identifier associated with this ATM bulk virtual circuit
name."
::= { juniAtmBulkCircuitsEntry 2 }
juniAtmBulkCircuitsInstance OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The unique identifier of the ATM bulk virtual circuit sub-range."
::= { juniAtmBulkCircuitsEntry 3 }
juniAtmBulkCircuitsRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table. Only the values
'createAndGo' and 'destroy' may be SET.
Since none of the VPI/VCI minimum and maximum values have default
values, all these values must be specified before setting RowStatus to
'createAndGo'. The VPI/VCI minimum and maximum values can only be
configured upon creation.
Deleting an entry in this table deletes corresponding entries in
juniAtmProfileOverrideAssignIfCircuitTable."
::= { juniAtmBulkCircuitsEntry 4 }
juniAtmBulkCircuitsMinVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The minimum value of VPI for this circuit sub-range. This value must
be less than or equal to the value of juniAtmBulkCircuitsMaxVpi."
::= { juniAtmBulkCircuitsEntry 5 }
juniAtmBulkCircuitsMaxVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum value of VPI for this cicuit sub-range. This value must
be equal to or greater than the value of juniAtmBulkCircuitsMinVpi."
::= { juniAtmBulkCircuitsEntry 6 }
juniAtmBulkCircuitsMinVci OBJECT-TYPE
SYNTAX AtmVcIdentifier
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The minimum value of VCI for this circuit sub-range. This value must
be less than or equal to the value of juniAtmBulkCircuitsMaxVci."
::= { juniAtmBulkCircuitsEntry 7 }
juniAtmBulkCircuitsMaxVci OBJECT-TYPE
SYNTAX AtmVcIdentifier
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum value of VCI for this circuit sub-range. This value must
be equal to or greater than the value of juniAtmBulkCircuitsMinVci."
::= { juniAtmBulkCircuitsEntry 8 }
juniAtmBulkCircuitsAdminState OBJECT-TYPE
SYNTAX JuniEnable
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The administrative status of this circuit sub-range."
DEFVAL { enable }
::= { juniAtmBulkCircuitsEntry 9 }
--
-- Assign overriding profile to interface/vpi/vci.
--
juniAtmProfileOverrideAssignIfCircuitTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmProfileOverrideAssignIfCircuitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table providing overriding profile assignment to a circuit configured
as part of bulk-configuration. Circuit is identified by interface index
and vpi, vci.
The entries in this table specify which profile to use when creating and
configuring a dynamic interface above a circuit specified by vpi and
vci.
This entry is effective when the circuit specified by
juniAtmProfileOverrideAssignIfCircuitAal5Index,
juniAtmProfileOverrideAssignIfCircuitRangeId,
juniAtmProfileOverrideAssignIfCircuitVpi,
juniAtmProfileOverrideAssignIfCircuitVci
is part of bulk-configuration."
::= { juniAtmAal5IfLayer 6 }
juniAtmProfileOverrideAssignIfCircuitEntry OBJECT-TYPE
SYNTAX JuniAtmProfileOverrideAssignIfCircuitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An assignment of a profile to a circuit configured as part of
bulk-configuration on an AAL5 interface."
INDEX { juniAtmProfileOverrideAssignIfCircuitAal5Index,
juniAtmProfileOverrideAssignIfCircuitRangeId,
juniAtmProfileOverrideAssignIfCircuitVpi,
juniAtmProfileOverrideAssignIfCircuitVci }
::= { juniAtmProfileOverrideAssignIfCircuitTable 1 }
JuniAtmProfileOverrideAssignIfCircuitEntry ::= SEQUENCE {
juniAtmProfileOverrideAssignIfCircuitAal5Index InterfaceIndex,
juniAtmProfileOverrideAssignIfCircuitRangeId Unsigned32,
juniAtmProfileOverrideAssignIfCircuitVpi AtmVpIdentifier,
juniAtmProfileOverrideAssignIfCircuitVci AtmVcIdentifier,
juniAtmProfileOverrideAssignIfCircuitRowStatus RowStatus,
juniAtmProfileOverrideAssignIfCircuitProfileId Unsigned32,
juniAtmProfileOverrideAssignIfCircuitOperStatus INTEGER }
juniAtmProfileOverrideAssignIfCircuitAal5Index OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of the AAL5 interface to which the profile is assigned."
::= { juniAtmProfileOverrideAssignIfCircuitEntry 1 }
juniAtmProfileOverrideAssignIfCircuitRangeId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The integer identifier associated with the ATM bulk circuit
configuration."
::= { juniAtmProfileOverrideAssignIfCircuitEntry 2 }
juniAtmProfileOverrideAssignIfCircuitVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VPI value of the circuit to which the profile is assigned."
::= { juniAtmProfileOverrideAssignIfCircuitEntry 3 }
juniAtmProfileOverrideAssignIfCircuitVci OBJECT-TYPE
SYNTAX AtmVcIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VCI value of the circuit to which the profile is assigned."
::= { juniAtmProfileOverrideAssignIfCircuitEntry 4 }
juniAtmProfileOverrideAssignIfCircuitRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table. Only the values
'createAndGo' and 'destroy' may be SET.
Since the VPI, VCI and profileId values do not have any default
values, all these values must be specified before setting RowStatus to
'createAndGo'. The VPI, VCI and profileId values can only be
configured upon creation. None of these values can be modified except
by deleting the entry."
::= { juniAtmProfileOverrideAssignIfCircuitEntry 5 }
juniAtmProfileOverrideAssignIfCircuitProfileId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ID of the profile assigned to the circuit configured as part of
bulk-configuration. Circuit is identified by interface index and vpi,
vci."
::= { juniAtmProfileOverrideAssignIfCircuitEntry 6 }
juniAtmProfileOverrideAssignIfCircuitOperStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational status of the profile override assignment identified
by this entry.
It returns inactive(0), if a static ATM circuit with identical VPI/VCI
values is present on the same ATM interface. In this case, this
profile override will not be used to configure upper dynamic
interfaces.
It returns active(1), if no static ATM circuit with identical VPI/VCI
values is present on the same ATM interface. In this case, this
profile override will be used to configure upper dynamic interfaces."
::= { juniAtmProfileOverrideAssignIfCircuitEntry 7 }
-- /////////////////////////////////////////////////////////////////////////////
--
-- ATM SUBINTERFACE LAYER
--
-- /////////////////////////////////////////////////////////////////////////////
--
-- IfIndex selection for creating new ATM Subinterfaces
--
juniAtmSubIfNextIfIndex OBJECT-TYPE
SYNTAX JuniNextIfIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Coordinate ifIndex value allocation for entries in juniAtmSubIfTable.
A GET of this object returns the next available ifIndex value to be used
to create an entry in the associated interface table; or zero, if no
valid ifIndex value is available. This object also returns a value of
zero when it is the lexicographic successor of a varbind presented in an
SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
that ifIndex allocation is unintended.
Successive GETs will typically return different values, thus avoiding
collisions among cooperating management clients seeking to create table
entries simultaneously."
::= { juniAtmSubIfLayer 1 }
--
-- The ATM Subinterface Table
--
juniAtmSubIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmSubIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for ATM Subinterfaces present in the
system."
::= { juniAtmSubIfLayer 2 }
juniAtmSubIfEntry OBJECT-TYPE
SYNTAX JuniAtmSubIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describes the characteristics of an ATM Subinterface.
Creating/deleting entries in this table causes corresponding entries for
be created/deleted in ifTable/ifXTable/juniIfTable."
INDEX { juniAtmSubIfIndex }
::= { juniAtmSubIfTable 1 }
JuniAtmSubIfEntry ::= SEQUENCE {
juniAtmSubIfIndex InterfaceIndex,
juniAtmSubIfRowStatus RowStatus,
juniAtmSubIfDistinguisher Integer32,
juniAtmSubIfLowerIfIndex InterfaceIndexOrZero,
juniAtmSubIfNbma TruthValue,
juniAtmSubIfAddress AtmAddr,
juniAtmSubIfMtu Integer32,
juniAtmSubIfAdvisoryRxSpeed Integer32,
juniAtmSubIfMartiniMaxCellsPerPacket Integer32,
juniAtmSubIfMartiniTimeoutTimerId Integer32,
juniAtmSubIfAssociatedVcClassId Unsigned32
}
juniAtmSubIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of the ATM Subinterface. When creating entries in this
table, suitable values for this object are determined by reading
juniAtmSubNextIfIndex."
::= { juniAtmSubIfEntry 1 }
juniAtmSubIfRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniAtmSubIfRowStatus
juniAtmSubIfLowerIndex
In addition, when creating an entry the following condition must hold:
A value for juniAtmSubIfIndex must have been determined previously,
by reading juniAtmSubIfNextIfIndex.
A corresponding entry in ifTable/ifXTable/juniIfTable is created or
destroyed as a result of creating/destroying an entry in this table."
::= { juniAtmSubIfEntry 2 }
juniAtmSubIfDistinguisher OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An integer identifier for the subinterface, used in conjunction with
the command-line interface. It is provided here for cross-reference
purposes only.
The value must be unique among subinterfaces configured on the same
underlying ATM adaptation layer. The upper bound for the value is
further constrained to be identical with the maximum number of
subinterfaces supported by the lower interface.
If this object is not configured, a value will be allocated internally
and can be queried after table entry creation has succeeded."
::= { juniAtmSubIfEntry 3 }
juniAtmSubIfLowerIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ifIndex of an ATM AAL5 interface over which this ATM subinterface
is to be layered. A value of zero indicates no layering. An
implementation may choose to require that a nonzero value be configured
at entry creation."
::= { juniAtmSubIfEntry 4 }
juniAtmSubIfNbma OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The NBMA administrative setting. Setting this value of this object to
true(1) will enable multipoint access on this interface. Setting the
value to false(2), will enable point to point access on this interface."
DEFVAL { false }
::= { juniAtmSubIfEntry 5 }
juniAtmSubIfAddress OBJECT-TYPE
SYNTAX AtmAddr (SIZE(0|7|20))
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Specifies the local ATM NSAP address of the circuit. A GET operation
returns a full 20-octet NSAP. A SET operation only requires 7 octets,
since the prefix can be implied."
DEFVAL { ''H }
::= { juniAtmSubIfEntry 6 }
juniAtmSubIfMtu OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The size of the largest packet which can be sent/received on the
interface, specified in octets."
DEFVAL { 9180 }
::= { juniAtmSubIfEntry 7 }
juniAtmSubIfAdvisoryRxSpeed OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Advisory receive speed, in kilobits per second (kbps),
of this subinterface. This object has no impact on
forwarding performance but may be used as a hint for
underlying circuit receive speed."
DEFVAL { 0 }
::= { juniAtmSubIfEntry 8 }
juniAtmSubIfMartiniMaxCellsPerPacket OBJECT-TYPE
SYNTAX Integer32 (1..190)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of cells that can be aggregated in a single ATM Martini
packet in cell-relay mode."
DEFVAL { 1 }
::= { juniAtmSubIfEntry 9 }
juniAtmSubIfMartiniTimeoutTimerId OBJECT-TYPE
SYNTAX Integer32 (1..3)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The timer identifier used to abandon cell aggregation when no
cells are supplied for transmission in ATM Martini cell-relay mode."
DEFVAL { 1 }
::= { juniAtmSubIfEntry 10 }
juniAtmSubIfAssociatedVcClassId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The integer identifier of the ATM VC class associated with this ATM
sub interface. A value for this identifier is determined by locating or
creating an ATM VC class name in the juniAtmVcClassNameTable. A value of 0
means no VC class association exists for this interface."
DEFVAL { 0 }
::= { juniAtmSubIfEntry 11 }
--
-- The ATM Subinterface VCC Table
--
juniAtmSubIfVccTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmSubIfVccEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for ATM VCCs configured on ATM
subinterfaces present in the system.
An implementation may constrain the number of VCCs permitted to be
configured per ATM Subinterface; in particular, an implementation may
restrict each ATM Subinterface to have a single VCC.
Attributes in this entry can only be configured at entry creation, and
remain fixed for the lifetime of the entry."
::= { juniAtmSubIfLayer 3 }
juniAtmSubIfVccEntry OBJECT-TYPE
SYNTAX JuniAtmSubIfVccEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describes the characteristics of an ATM subinterface VCC."
INDEX { juniAtmSubIfIndex,
juniAtmSubIfVccVpi,
juniAtmSubIfVccVci }
::= { juniAtmSubIfVccTable 1 }
JuniAtmSubIfVccEntry ::= SEQUENCE {
juniAtmSubIfVccVpi AtmVpIdentifier,
juniAtmSubIfVccVci AtmVcIdentifier,
juniAtmSubIfVccRowStatus RowStatus,
juniAtmSubIfVccVcd Integer32,
juniAtmSubIfVccType INTEGER,
juniAtmSubIfVccServiceCategory INTEGER,
juniAtmSubIfVccPcr Integer32,
juniAtmSubIfVccScr Integer32,
juniAtmSubIfVccMbs Integer32,
juniAtmSubIfInverseArp TruthValue,
juniAtmSubIfInverseArpRefresh Integer32,
juniAtmSubIfVccAssociatedVcClassId Unsigned32 }
juniAtmSubIfVccVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VPI of the ATM VCC used by this subinterface."
::= { juniAtmSubIfVccEntry 1 }
juniAtmSubIfVccVci OBJECT-TYPE
SYNTAX AtmVcIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VCI of the ATM VCC used by this subinterface."
::= { juniAtmSubIfVccEntry 2 }
juniAtmSubIfVccRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniAtmSubIfVccRowStatus
In addition, when creating an entry the following conditions must hold:
The ATM Subinterface identified by juniAtmSubIfIndex must exist.
A positive value configured for juniAtmSubIfVccVcd must not already
be assigned to an existing VCC.
For each value of juniAtmSubIfVccServiceCategory, additional
dependent objects in the entry require configuration as identified
here:
juniAtmSubIfVccServiceCategory Requires configuration of:
------------------------------------------------------------
ubr <none>
ubrPcr juniAtmSubIfVccPcr
nrtVbr juniAtmSubIfVccPcr
juniAtmSubIfVccScr
juniAtmSubIfVccMbs
cbr juniAtmSubIfVccPcr
rtVbr juniAtmSubIfVccPcr
juniAtmSubIfVccScr
juniAtmSubIfVccMbs
------------------------------------------------------------
Attributes in this entry can only be configured at entry creation,
and remain fixed for the lifetime of the entry."
::= { juniAtmSubIfVccEntry 3 }
juniAtmSubIfVccVcd OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An integer identifier for the circuit, used in conjunction with the
command-line interface. It is provided here for cross-reference
purposes only.
The value must be unique among VCCs configured on the same underlying
ATM interface.
If this object is not configured, or is configured with a value of zero,
a value will be allocated internally and can be queried after table
entry creation has succeeded."
::= { juniAtmSubIfVccEntry 4 }
juniAtmSubIfVccType OBJECT-TYPE
SYNTAX INTEGER {
rfc1483VcMux(0),
rfc1483Llc(1),
autoconfig(2),
aal5(3),
aal0(4) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the encapsulation used by the circuit to carry IP datagrams.
Encapsulations are as specified in RFC1483 Multiprotocol Interconnect
over ATM. The 'autoconfig' value will recognize both VcMux and LLC
formats. The 'aal5' and 'aal0' values are used for encapsulation
methods for transport of ATM frames and cells over IP and MPLS networks
when no encapsulation method is specified."
DEFVAL { rfc1483VcMux }
::= { juniAtmSubIfVccEntry 5 }
juniAtmSubIfVccServiceCategory OBJECT-TYPE
SYNTAX INTEGER {
ubr(0),
ubrPcr(1),
nrtVbr(2),
cbr(3),
rtVbr(4) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Service category for this circuit:
ubr Unspecified Bit Rate (best effort).
ubrPcr Unspecified Bit Rate with Peak Cell Rate limit.
nrtVbr Non-RealTime Variable Bit Rate.
cbr Constant Bit Rate.
rtVbr Realtime Variable Bit Rate."
DEFVAL { ubr }
::= { juniAtmSubIfVccEntry 6 }
juniAtmSubIfVccPcr OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "kbps"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Peak Cell Rate, in kilobits per second (kbps), of this circuit.
This parameter is only required when juniAtmSubIfVccServiceCategory is
configured to have one of the following values:
ubrPcr
nrtVbr
cbr
rtVbr "
DEFVAL { 0 }
::= { juniAtmSubIfVccEntry 7 }
juniAtmSubIfVccScr OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "kbps"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Sustained Cell Rate, in kilobits per second (kbps), of this circuit.
This parameter is only required when juniAtmSubIfVccServiceCategory is
configured to have the following value:
nrtVbr
rtVbr "
DEFVAL { 0 }
::= { juniAtmSubIfVccEntry 8 }
juniAtmSubIfVccMbs OBJECT-TYPE
SYNTAX Integer32 (0..16777215)
UNITS "cells"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Maximum Burst Size, in cells, of this circuit.
This parameter is only required when juniAtmSubIfVccServiceCategory is
configured to have the following value:
nrtVbr
rtVbr "
DEFVAL { 0 }
::= { juniAtmSubIfVccEntry 9 }
juniAtmSubIfInverseArp OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enables the inverse ARP protocol on this VCC; true(1) enables the
protocol, false(2) disables it."
::= { juniAtmSubIfVccEntry 10 }
juniAtmSubIfInverseArpRefresh OBJECT-TYPE
SYNTAX Integer32 (0..60)
UNITS "minutes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The refresh rate in minutes between inverse ARP protocol messages."
::= { juniAtmSubIfVccEntry 11 }
juniAtmSubIfVccAssociatedVcClassId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The integer identifier of the ATM VC class associated with this ATM
sub interface. A value for this identifier is determined by locating or
creating an ATM VC class name in the juniAtmVcClassNameTable. A value
of 0 means no VC class association exists for this VC."
DEFVAL { 0 }
::= { juniAtmSubIfVccEntry 12 }
--
-- The ATM OAM Table
--
juniAtmCircuitOamTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmCircuitOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains circuit OAM data for a PVC."
::= { juniAtmSubIfLayer 4 }
juniAtmCircuitOamEntry OBJECT-TYPE
SYNTAX JuniAtmCircuitOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry provides OAM data on an ATM PVC."
INDEX { juniAtmCircuitOamIfIndex,
juniAtmCircuitOamVpi,
juniAtmCircuitOamVci }
::= { juniAtmCircuitOamTable 1 }
JuniAtmCircuitOamEntry ::= SEQUENCE {
juniAtmCircuitOamIfIndex InterfaceIndex,
juniAtmCircuitOamVpi AtmVpIdentifier,
juniAtmCircuitOamVci AtmVcIdentifier,
juniAtmCircuitOamAdminStatus INTEGER,
juniAtmCircuitOamLoopbackOperStatus INTEGER,
juniAtmCircuitVcOamOperStatus INTEGER,
juniAtmCircuitOamLoopbackFrequency Integer32,
juniAtmCircuitInOamF5Cells Counter32,
juniAtmCircuitInOamCellsDropped Counter32,
juniAtmCircuitOutOamF5Cells Counter32,
juniAtmCircuitInOamF5EndToEndLoopbackCells Counter32,
juniAtmCircuitInOamF5SegmentLoopbackCells Counter32,
juniAtmCircuitInOamF5AisCells Counter32,
juniAtmCircuitInOamF5RdiCells Counter32,
juniAtmCircuitOutOamF5EndToEndLoopbackCells Counter32,
juniAtmCircuitOutOamF5SegmentLoopbackCells Counter32,
juniAtmCircuitOutOamF5RdiCells Counter32,
juniAtmCircuitInOamF5EndToEndLoopbackCmds Counter32,
juniAtmCircuitInOamF5EndToEndLoopbackRsps Counter32,
juniAtmCircuitInOamF5SegmentLoopbackCmds Counter32,
juniAtmCircuitInOamF5SegmentLoopbackRsps Counter32,
juniAtmCircuitOutOamF5EndToEndLoopbackCmds Counter32,
juniAtmCircuitOutOamF5EndToEndLoopbackRsps Counter32,
juniAtmCircuitOutOamF5SegmentLoopbackCmds Counter32,
juniAtmCircuitOutOamF5SegmentLoopbackRsps Counter32,
juniAtmCircuitOamUpCount Integer32,
juniAtmCircuitOamDownCount Integer32,
juniAtmCircuitOamRetryFrequency Integer32,
juniAtmCircuitOamAlarmDownCount Integer32,
juniAtmCircuitOamAlarmClearTimeout Integer32 }
juniAtmCircuitOamIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of the ATM subinterface."
::= { juniAtmCircuitOamEntry 1 }
juniAtmCircuitOamVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VPI of the ATM VCC used by this ATM interface and PVC."
::= { juniAtmCircuitOamEntry 2 }
juniAtmCircuitOamVci OBJECT-TYPE
SYNTAX AtmVcIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VCI of the ATM VCC used by this ATM interface and PVC."
::= { juniAtmCircuitOamEntry 3 }
juniAtmCircuitOamAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
oamAdminStateDisabled(1),
oamAdminStateEnabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administrative state of OAM for the interface identified by this
entry."
DEFVAL { oamAdminStateDisabled }
::= { juniAtmCircuitOamEntry 4 }
juniAtmCircuitOamLoopbackOperStatus OBJECT-TYPE
SYNTAX INTEGER {
oamOperStatusNotSupported(0),
oamOperStatusDisabled(1),
oamOperStatusSent(2),
oamOperStatusReceived(3),
oamOperStatusFailed(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational status of OAM for the interface identified by this
entry.
oamOperStatusNotSupported(0) - OAM not supported on this interface
oamOperStatusDisabled(1) - VC integrity disabled
oamOperStatusSent(2) - Loopback sent, awaiting response
oamOperStatusReceived(3) - Loopback response received, awaiting
frequency
oamOperStatusFailed(4) - Loopback response not received, or
invalid response received"
::= { juniAtmCircuitOamEntry 5 }
juniAtmCircuitVcOamOperStatus OBJECT-TYPE
SYNTAX INTEGER {
oamVcOperStateAisState(0),
oamVcOperStateRdiState(1),
oamVcOperStateDownRetry(2),
oamVcOperStateUpRetry(3),
oamVcOperStateUp(4),
oamVcOperStateDown(5),
oamVcOperStateNotManaged(6),
oamVcOperStateVpAis(7),
oamVcOperStateVpRdi(8),
oamVcOperStateVcInVpRdi(9),
oamVcoperStateVcInVpAis(10),
oamVcOperStateSegAis(11),
oamVcOperStateSegRdi(12),
oamVcOperStateGenAis(13)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OAM VC operational status of this entry.
oamVcOperStateAisState(0) - AIS cell received or underlying
physical layer reporting transmission
path AIS
oamVcOperStateRdiState(1) - RDI cell received
oamVcOperStateDownRetry(2) - OAM loopback failed, using retry
frequency to verify that the VC is
really down
oamVcOperStateUpRetry(3) - OAM loopback successful, using retry
frequency to verify that the VC is
really up
oamVcOperStateUp(4) - OAM loopback successful after up retry
verification
oamVcOperStateDown(5) - OAM loopback failed after down retry
verification
oamVcOperStateNotManaged(6)- No verification via loopback cells
being performed
oamVcOperStateVpAis(7) - F4 AIS cell received
oamVcOperStateVpRdi(8) - F4 RDI cell received
oamVcOperStateVcInVpRdi(9) - F4 RDI cell received; path failure
oamVcOperStateVcInVpAis(10)- F4 AIS cell received; path failure
oamVcOperStateSegAis(11) - Segment AIS cell received
oamVcOperStateSegRdi(12) - Segment RDI cell received
oamVcOperStateGenAis(13) - Connection failure; generating AIS
cells."
::= { juniAtmCircuitOamEntry 6 }
juniAtmCircuitOamLoopbackFrequency OBJECT-TYPE
SYNTAX Integer32 (1..600)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The OAM loopback frequency in seconds."
DEFVAL { 10 }
::= { juniAtmCircuitOamEntry 7 }
juniAtmCircuitInOamF5Cells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received OAM F5 cells."
::= { juniAtmCircuitOamEntry 8 }
juniAtmCircuitInOamCellsDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received OAM cells that were dropped."
::= { juniAtmCircuitOamEntry 9 }
juniAtmCircuitOutOamF5Cells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted OAM F5 cells."
::= { juniAtmCircuitOamEntry 10 }
juniAtmCircuitInOamF5EndToEndLoopbackCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total received OAM F5 end-to-end loopback cells. Aggregate of
juniAtmCircuitInOamF5EndToEndLoopbackCmds and
juniAtmCircuitInOamF5EndToEndLoopbackRsps"
::= { juniAtmCircuitOamEntry 11 }
juniAtmCircuitInOamF5SegmentLoopbackCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total received OAM F5 segment loopback cells. Aggregate of
juniAtmCircuitInOamF5SegmentLoopbackCmds and
juniAtmCircuitInOamF5SegmentLoopbackRsps"
::= { juniAtmCircuitOamEntry 12 }
juniAtmCircuitInOamF5AisCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received OAM F5 AIS cells."
::= { juniAtmCircuitOamEntry 13 }
juniAtmCircuitInOamF5RdiCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received OAM F5 RDI cells."
::= { juniAtmCircuitOamEntry 14 }
juniAtmCircuitOutOamF5EndToEndLoopbackCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total transmitted OAM F5 end-to-end loopback cells. Aggregate of
juniAtmCircuitOutOamF5EndToEndLoopbackCmds and
juniAtmCircuitOutOamF5EndToEndLoopbackRsps"
::= { juniAtmCircuitOamEntry 15 }
juniAtmCircuitOutOamF5SegmentLoopbackCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total transmitted OAM F5 segment loopback cells. Aggregate of
juniAtmCircuitOutOamF5SegmentLoopbackCmds and
juniAtmCircuitOutOamF5SegmentLoopbackRsps"
::= { juniAtmCircuitOamEntry 16 }
juniAtmCircuitOutOamF5RdiCells OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted OAM F5 RDI cells."
::= { juniAtmCircuitOamEntry 17 }
juniAtmCircuitInOamF5EndToEndLoopbackCmds OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received OAM F5 end-to-end loopback commands."
::= { juniAtmCircuitOamEntry 18 }
juniAtmCircuitInOamF5EndToEndLoopbackRsps OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received OAM F5 end-to-end loopback responses."
::= { juniAtmCircuitOamEntry 19 }
juniAtmCircuitInOamF5SegmentLoopbackCmds OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received OAM F5 segment loopback commands."
::= { juniAtmCircuitOamEntry 20 }
juniAtmCircuitInOamF5SegmentLoopbackRsps OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received OAM F5 segment loopback responses."
::= { juniAtmCircuitOamEntry 21 }
juniAtmCircuitOutOamF5EndToEndLoopbackCmds OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted OAM F5 end-to-end loopback commands."
::= { juniAtmCircuitOamEntry 22 }
juniAtmCircuitOutOamF5EndToEndLoopbackRsps OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted OAM F5 end-to-end loopback responses."
::= { juniAtmCircuitOamEntry 23 }
juniAtmCircuitOutOamF5SegmentLoopbackCmds OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted OAM F5 segment loopback commands."
::= { juniAtmCircuitOamEntry 24 }
juniAtmCircuitOutOamF5SegmentLoopbackRsps OBJECT-TYPE
SYNTAX Counter32
UNITS "cells"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted OAM F5 segment loopback responses."
::= { juniAtmCircuitOamEntry 25 }
juniAtmCircuitOamUpCount OBJECT-TYPE
SYNTAX Integer32 (1..60)
UNITS "cells"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the number of successive loopback cell responses to receive
before a PVC is up for connectivity verification."
DEFVAL { 3 }
::= { juniAtmCircuitOamEntry 26 }
juniAtmCircuitOamDownCount OBJECT-TYPE
SYNTAX Integer32 (1..60)
UNITS "cells"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the number of successive loopback cell responses not received
before declaring a PVC down for connectivity verification."
DEFVAL { 5 }
::= { juniAtmCircuitOamEntry 27 }
juniAtmCircuitOamRetryFrequency OBJECT-TYPE
SYNTAX Integer32 (1..600)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the frequency (in seconds) to transmit loopback cells when
verifying PVC state (up or down) for connectivity verification."
DEFVAL { 1 }
::= { juniAtmCircuitOamEntry 28 }
juniAtmCircuitOamAlarmDownCount OBJECT-TYPE
SYNTAX Integer32 (1..60)
UNITS "cells"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the number of successive alarm (AIS or RDI) cells to receive
before declaring a PVC down."
DEFVAL { 1 }
::= { juniAtmCircuitOamEntry 29 }
juniAtmCircuitOamAlarmClearTimeout OBJECT-TYPE
SYNTAX Integer32 (3..60)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies how long to wait (in seconds) before declaring a PVC up after
it has stopped receiving alarm cells."
DEFVAL { 3 }
::= { juniAtmCircuitOamEntry 30 }
--
-- The ATM Subinterface VCC Traffic Shaping Table
--
juniAtmSubIfVccTrafficShapingTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmSubIfVccTrafficShapingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for traffic shaping of ATM VCCs configured
on ATM subinterfaces present in the system. This table augments the
juniAtmSubIfVccTable only for VCCs that support traffic shapping.
Attributes in this entry can only be configured at entry creation, and
remain fixed for the lifetime of the entry."
::= { juniAtmSubIfLayer 5 }
juniAtmSubIfVccTrafficShapingEntry OBJECT-TYPE
SYNTAX JuniAtmSubIfVccTrafficShapingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describes the traffic shping characteristics of an ATM
subinterface VCC."
AUGMENTS { juniAtmSubIfVccEntry }
::= { juniAtmSubIfVccTrafficShapingTable 1 }
JuniAtmSubIfVccTrafficShapingEntry ::= SEQUENCE {
juniAtmSubIfVccTrafficShapingCdvt Unsigned32,
juniAtmSubIfVccTrafficShapingClp0 TruthValue,
juniAtmSubIfVccTrafficShapingTagging TruthValue,
juniAtmSubIfVccTrafficShapingPoliceObserve TruthValue,
juniAtmSubIfVccTrafficShapingPacketShaping TruthValue }
juniAtmSubIfVccTrafficShapingCdvt OBJECT-TYPE
SYNTAX Unsigned32
UNITS "tenths of a microsecond"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The network cell delay variation tolerance (CDVT) in tenths of a
microsecond."
::= { juniAtmSubIfVccTrafficShapingEntry 1 }
juniAtmSubIfVccTrafficShapingClp0 OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies whether or not only CLP0 cells are to be policed according to
the traffic contract. CLP1 cells are forwarded on a best-effort basis
CLP-significant model for (VBR.2, VBR.3 conformance). Applicable only
for VBR circuits."
::= { juniAtmSubIfVccTrafficShapingEntry 2 }
juniAtmSubIfVccTrafficShapingTagging OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies whether or not CLP0 cells should be tagged for SCR policing
(VBR.3 conformance). Applicable only for VBR circuits."
::= { juniAtmSubIfVccTrafficShapingEntry 3 }
juniAtmSubIfVccTrafficShapingPoliceObserve OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies whether of not no policing action is to be taken (note the
double negative; if true(1) then no policing action will be taken; if
false(2) then policing action will be taken). Regardless of the state
of this object, all counters will be incremented."
::= { juniAtmSubIfVccTrafficShapingEntry 4 }
juniAtmSubIfVccTrafficShapingPacketShaping OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies whether of not to shape output traffic on a packet boundary."
::= { juniAtmSubIfVccTrafficShapingEntry 5 }
--
-- The juniAtmSubIfSvcConfigTable for ATM switched
-- virtual connections (SVCs).
--
juniAtmSubIfSvcConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmSubIfSvcConfigEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This table contains entries for extending the juniAtmSubIfTable to
configure switched virtual connection (SVC) on the subinterfaces."
::= { juniAtmSubIfLayer 6 }
juniAtmSubIfSvcConfigEntry OBJECT-TYPE
SYNTAX JuniAtmSubIfSvcConfigEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Each entry provides configuration parameters for an ATM SVC on the
subinterface."
INDEX { juniAtmSubIfIndex }
::= { juniAtmSubIfSvcConfigTable 1 }
JuniAtmSubIfSvcConfigEntry ::= SEQUENCE {
juniAtmSubIfSvcRowStatus RowStatus,
juniAtmSubIfSvcConfigDestAtmAddress AtmAddr,
juniAtmSubIfSvcConfigCircuitType INTEGER,
juniAtmSubIfSvcConfigServiceCategory INTEGER,
juniAtmSubIfSvcConfigPcr Unsigned32,
juniAtmSubIfSvcConfigScr Unsigned32,
juniAtmSubIfSvcConfigMbs Unsigned32,
juniAtmSubIfSvcConfigCdvt Unsigned32,
juniAtmSubIfSvcConfigClp0 TruthValue,
juniAtmSubIfSvcConfigTagging TruthValue,
juniAtmSubIfSvcConfigObserve TruthValue,
juniAtmSubIfSvcConfigPacketDiscard TruthValue,
juniAtmSubIfSvcConfigDestE164Address AtmAddr }
juniAtmSubIfSvcRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy "
::= { juniAtmSubIfSvcConfigEntry 1 }
juniAtmSubIfSvcConfigDestAtmAddress OBJECT-TYPE
SYNTAX AtmAddr (SIZE(20))
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Specifies the destination ATM NSAP address of the circuit."
::= { juniAtmSubIfSvcConfigEntry 2 }
juniAtmSubIfSvcConfigCircuitType OBJECT-TYPE
SYNTAX INTEGER {
rfc1483VcMux(0),
rfc1483Llc(1) }
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Specifies the encapsulation used by the circuit to carry IP datagrams.
Encapsulations are as specified in RFC1483 Multiprotocol Interconnect
over ATM."
DEFVAL { rfc1483VcMux }
::= { juniAtmSubIfSvcConfigEntry 3 }
juniAtmSubIfSvcConfigServiceCategory OBJECT-TYPE
SYNTAX INTEGER {
ubr(0),
ubrPcr(1),
nrtVbr(2),
cbr(3),
rtVbr(4) }
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Service category for this circuit:
ubr Unspecified Bit Rate (best effort).
ubrPcr Unspecified Bit Rate with Peak Cell Rate limit.
nrtVbr Non-RealTime Variable Bit Rate.
cbr Constant Bit Rate.
rtVbr Realtime Variable Bit Rate."
DEFVAL { ubr }
::= { juniAtmSubIfSvcConfigEntry 4 }
juniAtmSubIfSvcConfigPcr OBJECT-TYPE
SYNTAX Unsigned32
UNITS "kbps"
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Peak Cell Rate, in kilo-bits per second (kbps), of this circuit."
DEFVAL { 0 }
::= { juniAtmSubIfSvcConfigEntry 5 }
juniAtmSubIfSvcConfigScr OBJECT-TYPE
SYNTAX Unsigned32
UNITS "kbps"
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Sustained Cell Rate, in kilo-bits per second (kbps), of this circuit."
DEFVAL { 0 }
::= { juniAtmSubIfSvcConfigEntry 6 }
juniAtmSubIfSvcConfigMbs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "cells"
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Maximum Burst Size, in cells, of this circuit."
DEFVAL { 0 }
::= { juniAtmSubIfSvcConfigEntry 7 }
juniAtmSubIfSvcConfigCdvt OBJECT-TYPE
SYNTAX Unsigned32
UNITS "100us"
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"Specify the network Cell Delay Variation Tolerance."
::= { juniAtmSubIfSvcConfigEntry 8 }
juniAtmSubIfSvcConfigClp0 OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Specify that only CLP0 cells are to be policed according to the traffic
contract. CLP1 cells are forwarded on a best-effort basis
CLP-significant model for (VBR.2, VBR.3 conformance)."
::= { juniAtmSubIfSvcConfigEntry 9 }
juniAtmSubIfSvcConfigTagging OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Specify that CLP0 cells should be tagged for SCR policing (VBR.3
conformance)."
::= { juniAtmSubIfSvcConfigEntry 10 }
juniAtmSubIfSvcConfigObserve OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"Specify that no policing action is to be taken; only counters are
incremented."
::= { juniAtmSubIfSvcConfigEntry 11 }
juniAtmSubIfSvcConfigPacketDiscard OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Enable early packet Discard for this circuit."
::= { juniAtmSubIfSvcConfigEntry 12 }
juniAtmSubIfSvcConfigDestE164Address OBJECT-TYPE
SYNTAX AtmAddr (SIZE(0|8))
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"Specifies the destination ATM E164 address of the circuit."
::= { juniAtmSubIfSvcConfigEntry 13 }
--
-- The ATM subinterface description export object
--
juniAtmSubIfDescriptionExport OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enabling of this object will program the subinterface description down
to the applicable line card. Note, the subinterface description sent
down to the line card is a truncated version (32 bytes) of the ifAlias."
DEFVAL { false }
::= { juniAtmSubIfLayer 7 }
--
-- The ATM NBMA table
--
juniAtmNbmaMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmNbmaMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for ATM NBMA maps."
::= { juniAtmNbma 1 }
juniAtmNbmaMapEntry OBJECT-TYPE
SYNTAX JuniAtmNbmaMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describes the characteristics of an ATM NBMA map."
INDEX { juniAtmNbmaMapName,
juniAtmNbmaMapVcd }
::= { juniAtmNbmaMapTable 1 }
JuniAtmNbmaMapEntry ::= SEQUENCE {
juniAtmNbmaMapName JuniAtmNbmaMapName,
juniAtmNbmaMapVcd Integer32,
juniAtmNbmaMapIpAddress IpAddress,
juniAtmNbmaMapVpi AtmVpIdentifier,
juniAtmNbmaMapVci AtmVcIdentifier,
juniAtmNbmaMapIfIndex InterfaceIndexOrZero,
juniAtmNbmaMapBroadcast TruthValue,
juniAtmNbmaMapRowStatus RowStatus }
juniAtmNbmaMapName OBJECT-TYPE
SYNTAX JuniAtmNbmaMapName
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The NBMA map name."
::= { juniAtmNbmaMapEntry 1 }
juniAtmNbmaMapVcd OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An integer identifier for the ATM circuit, used in conjunction with the
command-line interface.
The value must be unique among VCs configured on the same ATM
interface."
::= { juniAtmNbmaMapEntry 2 }
juniAtmNbmaMapIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The IP address associated with this entry."
::= { juniAtmNbmaMapEntry 3 }
juniAtmNbmaMapVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI identifier of the ATM circuit."
::= { juniAtmNbmaMapEntry 4 }
juniAtmNbmaMapVci OBJECT-TYPE
SYNTAX AtmVcIdentifier
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VCI identifier of the ATM circuit."
::= { juniAtmNbmaMapEntry 5 }
juniAtmNbmaMapIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex of the ATM major interface associated with this entry.
The value of this object will be zero when the map is not applied
to an interface. "
::= { juniAtmNbmaMapEntry 6 }
juniAtmNbmaMapBroadcast OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The broadcast enable/disable setting for this entry. The value true(1)
enable broadcast support; disable(2) disabled broadcast support for this
entry."
::= { juniAtmNbmaMapEntry 7 }
juniAtmNbmaMapRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
Additional notes to aid the network manager:
- NBMA maps are not supported on dynamic interface.
- NBMA maps can only be applied to a single major ATM interface at a
time.
- NBMA maps cannot be deleted unless the map is removed from the ATM
interface (juniAtmNbmaMapIfIndex = 0).
- The values of juniAtmNbmaMapVpi, juniAtmNbmaMapVci and
juniAtmNbmaMapIfIndex are zero until the map is applied to a major
ATM interface.
- To create an entry in this table, the following objects must be
present in the set PDU:
juniAtmNbmaMapIpAddress
juniAtmNbmaMapBroadcast
juniAtmNbmaMapRowStatus
- Once created, only the following objects can be modified:
juniAtmNbmaMapBroadcast "
::= { juniAtmNbmaMapEntry 8 }
juniAtmNbmaMapListTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmNbmaMapListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for ATM NBMA map lists."
::= { juniAtmNbma 2 }
juniAtmNbmaMapListEntry OBJECT-TYPE
SYNTAX JuniAtmNbmaMapListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describes the characteristics of an ATM NBMA map."
INDEX { IMPLIED juniAtmNbmaMapListName }
::= { juniAtmNbmaMapListTable 1 }
JuniAtmNbmaMapListEntry ::= SEQUENCE {
juniAtmNbmaMapListName JuniAtmNbmaMapName,
juniAtmNbmaMapListRowStatus RowStatus }
juniAtmNbmaMapListName OBJECT-TYPE
SYNTAX JuniAtmNbmaMapName
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The NBMA Map List name."
::= { juniAtmNbmaMapListEntry 1 }
juniAtmNbmaMapListRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy "
::= { juniAtmNbmaMapListEntry 2 }
--
-- The ATM ping tests.
--
--
-- ATM ping test types.
--
juniAtmPingTestTypes OBJECT IDENTIFIER
::= { juniAtmPing 1 }
juniAtmPingTestOamSeg OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This identifies an OAM Ping (multiple loopbacks) Test on a VPL, VPC,
VCL, or VCC termination point, using segment OAM cells.
The test type must have appended to it a code that uniquely identifies
an intermediate point responsible for looping back each cell. If this
is absent, the loopbacks are performed at the end of the segment or
connection.
E.g., the OID { juniAtmPingTestOamSeg 5 } identifies that the loopbacks
should be performed at the intermediate point labeled 5."
::= { juniAtmPingTestTypes 1 }
juniAtmPingTestOamE2E OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This identifies an OAM Ping (multiple loopbacks) Test on a VPL, VPC,
VCL, or VCC termination point, using end-to-end OAM cells."
::= { juniAtmPingTestTypes 2 }
--
-- The juniAtmVpPingTable extends the ATM-FORUM-SNMP-M4-MIB.atmM4VpTestTable.
--
juniAtmVpPingTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmVpPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for extending the ATM-FORUM-SNMP-M4-MIB
atmM4VpTestTable to do ping (multiple loopback) type testing."
::= { juniAtmPing 2 }
juniAtmVpPingEntry OBJECT-TYPE
SYNTAX JuniAtmVpPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describes the characteristics, status and results of the
most recent ATM ping test."
INDEX { ifIndex,
atmVplVpi,
atmfM4VpTestObject }
::= { juniAtmVpPingTable 1 }
JuniAtmVpPingEntry ::= SEQUENCE {
juniAtmVpPingProbeCount Unsigned32,
juniAtmVpPingTimeOut Unsigned32,
juniAtmVpPingCtlTrapGeneration BITS,
juniAtmVpPingSentProbes Unsigned32,
juniAtmVpPingProbeResponses Unsigned32,
juniAtmVpPingStartTime TimeStamp,
juniAtmVpPingMinRtt Unsigned32,
juniAtmVpPingMaxRtt Unsigned32,
juniAtmVpPingAverageRtt Unsigned32 }
juniAtmVpPingProbeCount OBJECT-TYPE
SYNTAX Unsigned32 (1..32)
UNITS "probes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of ping probes (OAM cells) to be sent to complete the test."
DEFVAL { 5 }
::= { juniAtmVpPingEntry 1 }
juniAtmVpPingTimeOut OBJECT-TYPE
SYNTAX Unsigned32 (1..5)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the time-out value, in seconds, for a remote ping operation."
DEFVAL { 5 }
::= { juniAtmVpPingEntry 2 }
juniAtmVpPingCtlTrapGeneration OBJECT-TYPE
SYNTAX BITS {
testCompletion(0) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object determines when and if to generate a
notification for this entry:
testCompletion(0) - Generate a juniPingTestCompleted notification.
The value of this object defaults to zero, indicating that no
notification has been selected."
DEFVAL { { } }
::= { juniAtmVpPingEntry 3 }
juniAtmVpPingSentProbes OBJECT-TYPE
SYNTAX Unsigned32
UNITS "probes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ping probes (OAM cells) that have been sent thus far for
this test. The value of this object MUST be set to zero when the
atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1)."
DEFVAL { 0 }
::= { juniAtmVpPingEntry 4 }
juniAtmVpPingProbeResponses OBJECT-TYPE
SYNTAX Unsigned32
UNITS "probes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ping responses that have been received thus far for this
test. The value of this object MUST be set to zero when the
atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1)."
DEFVAL { 0 }
::= { juniAtmVpPingEntry 5 }
juniAtmVpPingStartTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time (sysUpTime) when the test started."
DEFVAL { 0 }
::= { juniAtmVpPingEntry 6 }
juniAtmVpPingMinRtt OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The shortest round-trip-time (RTT) for the pings that have received
responses. The value of this object MUST be set to zero when the
atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). A
value of zero for this object implies that no ping responses have been
received for the current test."
::= { juniAtmVpPingEntry 7 }
juniAtmVpPingMaxRtt OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The longest round-trip-time (RTT) for the pings that have received
responses. The value of this object MUST be set to zero when the
atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). A
value of zero for this object implies that no ping responses have been
received for the current test."
::= { juniAtmVpPingEntry 8 }
juniAtmVpPingAverageRtt OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average round-trip-time (RTT) for all the pings that have received
responses. The value of this object MUST be set to zero when the
atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). A
value of zero for this object implies that no ping responses have been
received for the current test."
::= { juniAtmVpPingEntry 9 }
--
-- The juniAtmVcPingTable extends the ATM-FORUM-SNMP-M4-MIB.atmM4VcTestTable.
--
juniAtmVcPingTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmVcPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for extending the ATM-FORUM-SNMP-M4-MIB
atmM4VcTestTable to do ping (multiple loopback) type testing."
::= { juniAtmPing 3 }
juniAtmVcPingEntry OBJECT-TYPE
SYNTAX JuniAtmVcPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describes the characteristics, status and results of the
most recent ATM ping test."
INDEX { ifIndex,
atmVclVpi,
atmVclVci,
atmfM4VcTestObject }
::= { juniAtmVcPingTable 1 }
JuniAtmVcPingEntry ::= SEQUENCE {
juniAtmVcPingProbeCount Unsigned32,
juniAtmVcPingTimeOut Unsigned32,
juniAtmVcPingCtlTrapGeneration BITS,
juniAtmVcPingSentProbes Unsigned32,
juniAtmVcPingProbeResponses Unsigned32,
juniAtmVcPingStartTime TimeStamp,
juniAtmVcPingMinRtt Unsigned32,
juniAtmVcPingMaxRtt Unsigned32,
juniAtmVcPingAverageRtt Unsigned32 }
juniAtmVcPingProbeCount OBJECT-TYPE
SYNTAX Unsigned32 (1..32)
UNITS "probes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of ping probes (OAM cells) to be sent to complete the test."
DEFVAL { 5 }
::= { juniAtmVcPingEntry 1 }
juniAtmVcPingTimeOut OBJECT-TYPE
SYNTAX Unsigned32 (1..5)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the time-out value, in seconds, for a remote ping operation."
DEFVAL { 5 }
::= { juniAtmVcPingEntry 2 }
juniAtmVcPingCtlTrapGeneration OBJECT-TYPE
SYNTAX BITS {
testCompletion(0) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object determines when and if to generate a
notification for this entry:
testCompletion(0) - Generate a juniPingTestCompleted notification.
The value of this object defaults to zero, indicating that no
notification has been selected."
DEFVAL { { } }
::= { juniAtmVcPingEntry 3 }
juniAtmVcPingSentProbes OBJECT-TYPE
SYNTAX Unsigned32
UNITS "probes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ping probes (OAM cells) that have been sent thus far for
this test. The value of this object MUST be set to zero when the
atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1)."
DEFVAL { 0 }
::= { juniAtmVcPingEntry 4 }
juniAtmVcPingProbeResponses OBJECT-TYPE
SYNTAX Unsigned32
UNITS "probes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ping responses that have been received thus far for this
test. The value of this object MUST be set to zero when the
atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1)."
DEFVAL { 0 }
::= { juniAtmVcPingEntry 5 }
juniAtmVcPingStartTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time (sysUpTime) when the test started."
DEFVAL { 0 }
::= { juniAtmVcPingEntry 6 }
juniAtmVcPingMinRtt OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The shortest round-trip-time (RTT) for the pings that have received
responses. The value of this object MUST be set to zero when the
atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). A
value of zero for this object implies that no ping responses have been
received for the current test."
::= { juniAtmVcPingEntry 7 }
juniAtmVcPingMaxRtt OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The longest round-trip-time (RTT) for the pings that have received
responses. The value of this object MUST be set to zero when the
atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). A
value of zero for this object implies that no ping responses have been
received for the current test."
::= { juniAtmVcPingEntry 8 }
juniAtmVcPingAverageRtt OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average round-trip-time (RTT) for all the pings that have received
responses. The value of this object MUST be set to zero when the
atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). A
value of zero for this object implies that no ping responses have been
received for the current test."
::= { juniAtmVcPingEntry 9 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- ATM ping test codes.
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniAtmPingTestCode OBJECT IDENTIFIER ::= { juniAtmPing 4 }
juniAtmPingTestCodeOamDisabled OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This test code indicates that the ATM ping operation cannot be
initiated or is aborted because the juniAtmIfOamCellRxAdminState is set
to disabled."
::= { juniAtmPingTestCode 1 }
juniAtmPingTestCodeCircuitDown OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This test code indicates that the ATM ping operation cannot be
initiated or is aborted because the operational status of the ATM
circuit is down."
::= { juniAtmPingTestCode 2 }
juniAtmPingTestCodeStopped OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This test code indicates that the ATM ping operation is
administratively stopped by an External Management."
::= { juniAtmPingTestCode 3 }
juniAtmPingTestCodeOamVcOperState OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This test code indicates that the ATM ping operation cannot be
initiated or is aborted because the circuit is down because of a OAM
fault condition. This is possible if juniAtmCircuitVcOamOperStatus is
one of the following:
oamVcOperStateAisState(0) - AIS cell received or underlying
physical layer reporting transmission
path AIS.
oamVcOperStateRdiState(1) - RDI cell received."
::= { juniAtmPingTestCode 4 }
juniAtmPingTestCodeMaxPingCountReached OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This test code indicates that the ping operation cannot be initiated as
the maximum number of ping possible on this interfaces exceeds the
allowable limit."
::= { juniAtmPingTestCode 5 }
juniAtmPingTestCodeInvalidParams OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This Test Code identities the Ping operation cannot be initiated as one
or more of the Ping Parameters is Invalid."
::= { juniAtmPingTestCode 6 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- ATM Subinterface information by interface location
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniAtmSubIfLocationType OBJECT-TYPE
SYNTAX JuniInterfaceLocationType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the interpretation of JuniInterfaceLocationValue object
values into platform-dependent interface location components, e.g.,
'slot.port' on an ERX."
::= { juniAtmLocation 1 }
juniAtmSubIfLocationTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmSubIfLocationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entries in this table report the ifIndex of ATM Subinterfaces by
location."
::= { juniAtmLocation 2 }
juniAtmSubIfLocationEntry OBJECT-TYPE
SYNTAX JuniAtmSubIfLocationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A specification of ATM subinterfaces by location."
INDEX { juniAtmSubIfLocationIndex,
juniAtmSubIfDistinguisher }
::= { juniAtmSubIfLocationTable 1 }
JuniAtmSubIfLocationEntry ::= SEQUENCE {
juniAtmSubIfLocationIndex JuniInterfaceLocationValue,
juniAtmSubIfLocationIfIndex InterfaceIndex }
juniAtmSubIfLocationIndex OBJECT-TYPE
SYNTAX JuniInterfaceLocationValue
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of a platform interface location."
::= { juniAtmSubIfLocationEntry 1 }
juniAtmSubIfLocationIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex value of this subinterface."
::= { juniAtmSubIfLocationEntry 2 }
juniAtmVcClassNameTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmVcClassNameEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entries in this table provide mappings of ATM VC class names to
local integer identifiers. These integers are used as indexes into other
MIB tables containing ATM VC attributes associated with the same VC class name."
::= { juniAtmVcClass 1 }
juniAtmVcClassNameEntry OBJECT-TYPE
SYNTAX JuniAtmVcClassNameEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A mapping of ATM VC class name to an integer identifier for the ATM VC class."
INDEX { IMPLIED juniAtmVcClassName }
::= { juniAtmVcClassNameTable 1 }
JuniAtmVcClassNameEntry ::= SEQUENCE {
juniAtmVcClassName DisplayString,
juniAtmVcClassNameRowStatus RowStatus,
juniAtmVcClassNameId Unsigned32 }
juniAtmVcClassName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ATM VC class name uniquely identifying this entry."
::= { juniAtmVcClassNameEntry 1 }
juniAtmVcClassNameRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table. Only the values
'createAndGo' ,'destroy', 'active' and 'notInService' may be SET.
The SNMP manager would set the row status to notInService before making
any VC class attribute changes explained in juniAtmVcClassTable. Once the
VC class attribute changes are complete, the SNMP manager would set the
row status to active, upon which the VC class attribute changes would
be committed. Any ATM VC class attribute changes that are made when the
row status is 'active' are committed right away."
::= { juniAtmVcClassNameEntry 2 }
juniAtmVcClassNameId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The integer identifier associated with this VC class name. The value of
this identifier is assigned by the device when an entry in this table
is created."
::= { juniAtmVcClassNameEntry 3 }
juniAtmVcClassIdTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmVcClassIdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Provides inverse mapping of ATM VC class IDs to ATM VC class names."
::= { juniAtmVcClass 2 }
juniAtmVcClassIdEntry OBJECT-TYPE
SYNTAX JuniAtmVcClassIdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A mapping of an integer identifier to an ATM VC class name."
INDEX { juniAtmVcClassIdId }
::= { juniAtmVcClassIdTable 1 }
JuniAtmVcClassIdEntry ::= SEQUENCE {
juniAtmVcClassIdId Unsigned32,
juniAtmVcClassIdName DisplayString }
juniAtmVcClassIdId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The integer identifier associated with this ATM VC class name."
::= { juniAtmVcClassIdEntry 1 }
juniAtmVcClassIdName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ATM VC class name having the associated identifier."
::= { juniAtmVcClassIdEntry 2 }
--
--ATM VC class table
--
juniAtmVcClassTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniAtmVcClassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains Juniper ATM VC Class entries which can be used
to specify the ATM PVC attributes either at creation or modification
time. A row in this table with default values is created when an entry
in juniAtmVcClassNameTable is created."
::= { juniAtmVcClass 3 }
juniAtmVcClassEntry OBJECT-TYPE
SYNTAX JuniAtmVcClassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry contains the attributes of the ATM VC which would be
applied to the VC either at creation or modification time when this
ATM VC class is associated to it."
INDEX { juniAtmVcClassId }
::= { juniAtmVcClassTable 1 }
JuniAtmVcClassEntry ::= SEQUENCE {
juniAtmVcClassId Unsigned32,
juniAtmVcClassVccType INTEGER,
juniAtmVcClassVccServiceCategory INTEGER,
juniAtmVcClassVccPcr Integer32,
juniAtmVcClassVccScr Integer32,
juniAtmVcClassVccMbs Integer32,
juniAtmVcClassVccOamAdminStatus INTEGER,
juniAtmVcClassVccOamLoopbackFrequency Integer32,
juniAtmVcClassVccOamUpCount Integer32,
juniAtmVcClassVccOamDownCount Integer32,
juniAtmVcClassVccOamRetryFrequency Integer32,
juniAtmVcClassVccOamAlarmDownCount Integer32,
juniAtmVcClassVccOamAlarmClearTimeout Integer32,
juniAtmVcClassVccInverseArp TruthValue,
juniAtmVcClassVccInverseArpRefresh Integer32 }
juniAtmVcClassId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The integer identifier associated with this ATM VC class. A value
for this identifier is determined by locating or creating an ATM VC
class name in the juniAtmVcClassNameTable."
::= { juniAtmVcClassEntry 1 }
juniAtmVcClassVccType OBJECT-TYPE
SYNTAX INTEGER {
rfc1483VcMux(0),
rfc1483Llc(1),
autoconfig(2),
aal5(3),
aal0(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the encapsulation used by the circuit to carry IP datagrams.
Encapsulations are as specified in RFC1483 Multiprotocol Interconnect
over ATM. The 'autoconfig' value will recognize both VC Mux and LLC
formats. The 'aal5' and 'aal0' values are used for encapsulation
methods for transport of ATM frames and cells over IP and MPLS networks
when no encapsulation method is specified."
DEFVAL { rfc1483VcMux }
::= { juniAtmVcClassEntry 2 }
juniAtmVcClassVccServiceCategory OBJECT-TYPE
SYNTAX INTEGER {
ubr(0),
ubrPcr(1),
nrtVbr(2),
cbr(3),
rtVbr(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Service category for this circuit:
ubr Unspecified Bit Rate (best effort).
ubrPcr Unspecified Bit Rate with Peak Cell Rate limit.
nrtVbr Non-RealTime Variable Bit Rate.
cbr Constant Bit Rate.
rtVbr Realtime Variable Bit Rate."
DEFVAL { ubr }
::= { juniAtmVcClassEntry 3 }
juniAtmVcClassVccPcr OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Peak Cell Rate, in kilobits per second (kbps), of this circuit.
This parameter is only required when juniAtmVcClassVccServiceCategory is
configured to have one of the following values:
ubrPcr
nrtVbr
cbr
rtVbr "
DEFVAL { 0 }
::= { juniAtmVcClassEntry 4 }
juniAtmVcClassVccScr OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sustained Cell Rate, in kilobits per second (kbps), of this circuit.
This parameter is only required when juniAtmVcClassVccServiceCategory
is configured to have the following value:
nrtVbr
rtVbr "
DEFVAL { 0 }
::= { juniAtmVcClassEntry 5 }
juniAtmVcClassVccMbs OBJECT-TYPE
SYNTAX Integer32 (0..16777215)
UNITS "cells"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum Burst Size, in cells, of this circuit.
This parameter is only required when juniAtmVcClassVccServiceCategory
is configured to have the following value:
nrtVbr
rtVbr "
DEFVAL { 0 }
::= { juniAtmVcClassEntry 6 }
juniAtmVcClassVccOamAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
oamAdminStateDisabled(1),
oamAdminStateEnabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The OAM VC integrity administrative state of the ATM VC associated
with this class."
DEFVAL { oamAdminStateDisabled }
::= { juniAtmVcClassEntry 7 }
juniAtmVcClassVccOamLoopbackFrequency OBJECT-TYPE
SYNTAX Integer32 (1..600)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The OAM loopback frequency in seconds."
DEFVAL { 10 }
::= { juniAtmVcClassEntry 8 }
juniAtmVcClassVccOamUpCount OBJECT-TYPE
SYNTAX Integer32 (1..60)
UNITS "cells"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the number of successive loopback cell responses to
receive before the ATM VC associated with this class is declared
up for connectivity verification."
DEFVAL { 3 }
::= { juniAtmVcClassEntry 9 }
juniAtmVcClassVccOamDownCount OBJECT-TYPE
SYNTAX Integer32 (1..60)
UNITS "cells"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the number of successive loopback cell responses not
received before declaring the ATM VC associated with this class
as down for connectivity verification."
DEFVAL { 5 }
::= { juniAtmVcClassEntry 10 }
juniAtmVcClassVccOamRetryFrequency OBJECT-TYPE
SYNTAX Integer32 (1..600)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the frequency (in seconds) to transmit loopback cells
when verifying the ATM VC operational state associated with this
class (up or down) for connectivity verification."
DEFVAL { 1 }
::= { juniAtmVcClassEntry 11 }
juniAtmVcClassVccOamAlarmDownCount OBJECT-TYPE
SYNTAX Integer32 (1..60)
UNITS "cells"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the number of successive alarm (AIS or RDI) cells to
receive before declaring the ATM VC associated with class as down."
DEFVAL { 1 }
::= { juniAtmVcClassEntry 12 }
juniAtmVcClassVccOamAlarmClearTimeout OBJECT-TYPE
SYNTAX Integer32 (3..60)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies how long to wait (in seconds) before declaring the ATM VC
associated with class as up after it has stopped receiving alarm cells."
DEFVAL { 3 }
::= { juniAtmVcClassEntry 13 }
juniAtmVcClassVccInverseArp OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables the inverse ARP protocol on the ATM VC associated with this
class; true(1) enables the protocol, false(2) disables it."
::= { juniAtmVcClassEntry 14 }
juniAtmVcClassVccInverseArpRefresh OBJECT-TYPE
SYNTAX Integer32 (0..60)
UNITS "minutes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The refresh rate in minutes between inverse ARP protocol messages."
::= { juniAtmVcClassEntry 15 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Notification control objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- No global notification controls are defined. Placeholder follows.
-- juniAtmTrapControl OBJECT IDENTIFIER ::= { juniAtmMIB 2 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Notifications
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- The following two OBJECT IDENTIFIERS are used to define SNMPv2
-- Notifications that are easily translated into SNMPv1 Traps.
juniAtmTraps OBJECT IDENTIFIER ::= { juniAtmMIB 3 }
juniAtmTrapPrefix OBJECT IDENTIFIER ::= { juniAtmTraps 0 }
juniAtmVpPingTestCompleted NOTIFICATION-TYPE
OBJECTS {
atmfM4VpTestId,
atmfM4VpTestType,
atmfM4VpTestResult,
juniAtmVpPingProbeCount,
juniAtmVpPingSentProbes,
juniAtmVpPingProbeResponses,
juniAtmVpPingMinRtt,
juniAtmVpPingMaxRtt,
juniAtmVpPingAverageRtt,
atmfM4VpTestCode }
STATUS current
DESCRIPTION
"Generated at the completion of a AtmfM4VpTest when the corresponding
juniAtmVpPingCtlTrapGeneration object has the testCompletion(0) bit
set."
::= { juniAtmTrapPrefix 1 }
juniAtmVcPingTestCompleted NOTIFICATION-TYPE
OBJECTS {
atmfM4VcTestId,
atmfM4VcTestType,
atmfM4VcTestResult,
juniAtmVcPingProbeCount,
juniAtmVcPingSentProbes,
juniAtmVcPingProbeResponses,
juniAtmVcPingMinRtt,
juniAtmVcPingMaxRtt,
juniAtmVcPingAverageRtt,
atmfM4VcTestCode }
STATUS current
DESCRIPTION
"Generated at the completion of a AtmfM4VcTest when the corresponding
juniAtmVcPingCtlTrapGeneration object has the testCompletion(0) bit
set."
::= { juniAtmTrapPrefix 2 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Conformance information
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniAtmConformance OBJECT IDENTIFIER ::= { juniAtmMIB 4 }
juniAtmCompliances OBJECT IDENTIFIER ::= { juniAtmConformance 1 }
juniAtmGroups OBJECT IDENTIFIER ::= { juniAtmConformance 2 }
--
-- compliance statements
--
juniAtmCompliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"Obsolete compliance statement for entities which implement the Juniper
ATM MIB. This statement became obsolete when support was added for NBMA
map lists and ATM ping."
MODULE -- this module
MANDATORY-GROUPS {
juniAtmGroup,
juniAtmAal5Group,
juniAtmSubIfGroup }
GROUP juniAtmVpTunnelGroup
DESCRIPTION
"The juniAtmVpTunnelGroup is mandatory only for entities that
support a VP Tunnel functionality."
::= { juniAtmCompliances 1 } -- JUNOSe 3.0
juniAtmCompliance2 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"Obsolete compliance statement for entities which implement the Juniper
ATM MIB. This statement became obsolete when support was added for
traffic shapping on VCC subinterfaces."
MODULE -- this module
MANDATORY-GROUPS {
juniAtmGroup2,
juniAtmAal5Group,
juniAtmSubIfGroup2,
juniAtmVpPingControlGroup,
juniAtmVcPingControlGroup,
juniAtmPingTrapGroup }
GROUP juniAtmVpTunnelGroup
DESCRIPTION
"The juniAtmVpTunnelGroup is mandatory only for entities that
support a VP Tunnel functionality."
GROUP juniAtmNbmaMapGroup
DESCRIPTION
"The juniAtmNbmaMapGroup is mandatory only for entities that
support NBMA interfaces over ATM."
::= { juniAtmCompliances 2 } -- JUNOSe 3.2
juniAtmCompliance3 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"Obsolete compliance statement for entities which implement the Juniper
ATM MIB. This statement became obsolete when support was added for
connection admission control (CAC)."
MODULE -- this module
MANDATORY-GROUPS {
juniAtmGroup2,
juniAtmAal5Group,
juniAtmSubIfGroup2,
juniAtmVpPingControlGroup,
juniAtmVcPingControlGroup,
juniAtmPingTrapGroup }
GROUP juniAtmVpTunnelGroup
DESCRIPTION
"The juniAtmVpTunnelGroup is mandatory only for entities that
support a VP Tunnel functionality."
GROUP juniAtmNbmaMapGroup
DESCRIPTION
"The juniAtmNbmaMapGroup is mandatory only for entities that
support NBMA interfaces over ATM."
GROUP juniAtmTrafficShapingGroup
DESCRIPTION
"The juniAtmTrafficShapingGroup is mandatory only for entities
that support ATM traffic shaping."
::= { juniAtmCompliances 3 } -- JUNOSe 3.3
juniAtmCompliance4 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"Obsolete compliance statement for entities which implement the Juniper
ATM MIB. This statement became obsolete when ATM SVC, CAC used
bandwidth and sub-interface address objects were added."
MODULE -- this module
MANDATORY-GROUPS {
juniAtmGroup3,
juniAtmAal5Group,
juniAtmSubIfGroup2,
juniAtmVpPingControlGroup,
juniAtmVcPingControlGroup,
juniAtmPingTrapGroup }
GROUP juniAtmVpTunnelGroup
DESCRIPTION
"The juniAtmVpTunnelGroup is mandatory only for entities that
support a VP Tunnel functionality."
GROUP juniAtmNbmaMapGroup
DESCRIPTION
"The juniAtmNbmaMapGroup is mandatory only for entities that
support NBMA interfaces over ATM."
GROUP juniAtmTrafficShapingGroup
DESCRIPTION
"The juniAtmTrafficShapingGroup is mandatory only for entities
that support ATM traffic shaping."
::= { juniAtmCompliances 4 } -- JUNOSe 3.4
juniAtmCompliance5 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"Obsolete compliance statement for entities which implement the Juniper
ATM MIB. This statement became obsolete when CAC recieve bandwith and
E164 public addressing support was added."
MODULE -- this module
MANDATORY-GROUPS {
juniAtmGroup4,
juniAtmAal5Group,
juniAtmSubIfGroup3,
juniAtmVpPingControlGroup,
juniAtmVcPingControlGroup,
juniAtmPingTrapGroup,
juniAtmSvcGroup }
GROUP juniAtmVpTunnelGroup
DESCRIPTION
"The juniAtmVpTunnelGroup is mandatory only for entities that
support a VP Tunnel functionality."
GROUP juniAtmNbmaMapGroup
DESCRIPTION
"The juniAtmNbmaMapGroup is mandatory only for entities that
support NBMA interfaces over ATM."
GROUP juniAtmTrafficShapingGroup
DESCRIPTION
"The juniAtmTrafficShapingGroup is mandatory only for entities
that support ATM traffic shaping."
::= { juniAtmCompliances 5 } -- JUNOSe 4.0
juniAtmCompliance6 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"Obsolete compliance statement for entities which implement the Juniper
ATM MIB. This statement became obsolete when F4 flow OAM circuit config
and stats tables were added to the Juniper ATM MIB."
MODULE -- this module
MANDATORY-GROUPS {
juniAtmGroup5,
juniAtmAal5Group,
juniAtmSubIfGroup4,
juniAtmVpPingControlGroup,
juniAtmVcPingControlGroup,
juniAtmPingTrapGroup,
juniAtmSvcGroup2 }
GROUP juniAtmVpTunnelGroup
DESCRIPTION
"The juniAtmVpTunnelGroup is mandatory only for entities that
support a VP Tunnel functionality."
GROUP juniAtmNbmaMapGroup
DESCRIPTION
"The juniAtmNbmaMapGroup is mandatory only for entities that
support NBMA interfaces over ATM."
GROUP juniAtmTrafficShapingGroup
DESCRIPTION
"The juniAtmTrafficShapingGroup is mandatory only for entities
that support ATM traffic shaping."
GROUP juniAtmPnniGroup
DESCRIPTION
"The juniAtmPnniGroup is mandatory only for entities that
support PNNI routing for ATM networks."
::= { juniAtmCompliances 6 } -- JUNOSe 4.1
juniAtmCompliance7 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"Obsolete compliance statement for entities which implement the Juniper
ATM MIB. This statement became obsolete when the juniAtmLocationGroup
was added."
MODULE -- this module
MANDATORY-GROUPS {
juniAtmGroup6,
juniAtmAal5Group,
juniAtmSubIfGroup4,
juniAtmVpPingControlGroup,
juniAtmVcPingControlGroup,
juniAtmPingTrapGroup,
juniAtmSvcGroup2,
juniAtmF4OamCircuitGroup }
GROUP juniAtmVpTunnelGroup
DESCRIPTION
"The juniAtmVpTunnelGroup is mandatory only for entities that
support a VP Tunnel functionality."
GROUP juniAtmNbmaMapGroup
DESCRIPTION
"The juniAtmNbmaMapGroup is mandatory only for entities that
support NBMA interfaces over ATM."
GROUP juniAtmTrafficShapingGroup
DESCRIPTION
"The juniAtmTrafficShapingGroup is mandatory only for entities
that support ATM traffic shaping."
GROUP juniAtmPnniGroup
DESCRIPTION
"The juniAtmPnniGroup is mandatory only for entities that
support PNNI routing for ATM networks."
::= { juniAtmCompliances 7 } -- JUNOSe 5.1
juniAtmCompliance8 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"Obsolete compliance statement for entities which implement the Juniper
ATM MIB. This statement became obsolete when support was added to
export the subinterface description to the line cards."
MODULE -- this module
MANDATORY-GROUPS {
juniAtmGroup6,
juniAtmAal5Group,
juniAtmSubIfGroup4,
juniAtmVpPingControlGroup,
juniAtmVcPingControlGroup,
juniAtmPingTrapGroup,
juniAtmSvcGroup2,
juniAtmF4OamCircuitGroup }
GROUP juniAtmVpTunnelGroup
DESCRIPTION
"The juniAtmVpTunnelGroup is mandatory only for entities that
support a VP Tunnel functionality."
GROUP juniAtmNbmaMapGroup
DESCRIPTION
"The juniAtmNbmaMapGroup is mandatory only for entities that
support NBMA interfaces over ATM."
GROUP juniAtmTrafficShapingGroup
DESCRIPTION
"The juniAtmTrafficShapingGroup is mandatory only for entities
that support ATM traffic shaping."
GROUP juniAtmPnniGroup
DESCRIPTION
"The juniAtmPnniGroup is mandatory only for entities that
support PNNI routing for ATM networks."
GROUP juniAtmLocationGroup
DESCRIPTION
"The juniAtmLocationGroup is mandatory only for entities that
support slot and port interface location information"
::= { juniAtmCompliances 8 } -- JUNOSe 5.2
juniAtmCompliance9 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"Obsolete compliance statement for entities which implement the Juniper
ATM MIB. This statement was obsoleted when the juniAtmMartiniGroup was
added."
MODULE -- this module
MANDATORY-GROUPS {
juniAtmGroup6,
juniAtmAal5Group,
juniAtmSubIfGroup5,
juniAtmVpPingControlGroup,
juniAtmVcPingControlGroup,
juniAtmPingTrapGroup,
juniAtmSvcGroup2,
juniAtmF4OamCircuitGroup }
GROUP juniAtmVpTunnelGroup
DESCRIPTION
"The juniAtmVpTunnelGroup is mandatory only for entities that
support a VP Tunnel functionality."
GROUP juniAtmNbmaMapGroup
DESCRIPTION
"The juniAtmNbmaMapGroup is mandatory only for entities that
support NBMA interfaces over ATM."
GROUP juniAtmTrafficShapingGroup
DESCRIPTION
"The juniAtmTrafficShapingGroup is mandatory only for entities
that support ATM traffic shaping."
GROUP juniAtmPnniGroup
DESCRIPTION
"The juniAtmPnniGroup is mandatory only for entities that
support PNNI routing for ATM networks."
GROUP juniAtmLocationGroup
DESCRIPTION
"The juniAtmLocationGroup is mandatory only for entities that
support slot and port interface location information"
::= { juniAtmCompliances 9 } -- JUNOSe 5.3
juniAtmCompliance10 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"Obsolete compliance statement for entities which implement the Juniper
ATM MIB. This statement became obsolete when
juniAtmIfCacAvailableBandwidthRx, juniAtmIfE164Autoconversion,
juniAtmIfE164Gateway, and juniAtmIfE164OneToOneAddrTrans were
deprecated."
MODULE -- this module
MANDATORY-GROUPS {
juniAtmGroup6,
juniAtmAal5Group,
juniAtmSubIfGroup5,
juniAtmVpPingControlGroup,
juniAtmVcPingControlGroup,
juniAtmPingTrapGroup,
juniAtmSvcGroup2,
juniAtmF4OamCircuitGroup }
GROUP juniAtmVpTunnelGroup
DESCRIPTION
"The juniAtmVpTunnelGroup is mandatory only for entities that
support a VP Tunnel functionality."
GROUP juniAtmNbmaMapGroup
DESCRIPTION
"The juniAtmNbmaMapGroup is mandatory only for entities that
support NBMA interfaces over ATM."
GROUP juniAtmTrafficShapingGroup
DESCRIPTION
"The juniAtmTrafficShapingGroup is mandatory only for entities
that support ATM traffic shaping."
GROUP juniAtmPnniGroup
DESCRIPTION
"The juniAtmPnniGroup is mandatory only for entities that
support PNNI routing for ATM networks."
GROUP juniAtmLocationGroup
DESCRIPTION
"The juniAtmLocationGroup is mandatory only for entities that
support slot and port interface location information"
GROUP juniAtmMartiniGroup
DESCRIPTION
"The juniAtmMartiniGroup is mandatory only for entities that
support ATM Martini cell aggregation configuration"
::= { juniAtmCompliances 10 } -- JUNOSe 6.0
juniAtmCompliance11 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"Obsolete compliance statement for entities which implement the Juniper
ATM MIB. This statement became obsolete when juniAtmGroup8 was
added."
MODULE -- this module
MANDATORY-GROUPS {
juniAtmGroup7,
juniAtmAal5Group,
juniAtmSubIfGroup5,
juniAtmVpPingControlGroup,
juniAtmVcPingControlGroup,
juniAtmPingTrapGroup,
juniAtmSvcGroup2,
juniAtmF4OamCircuitGroup }
GROUP juniAtmVpTunnelGroup
DESCRIPTION
"The juniAtmVpTunnelGroup is mandatory only for entities that
support a VP Tunnel functionality."
GROUP juniAtmNbmaMapGroup
DESCRIPTION
"The juniAtmNbmaMapGroup is mandatory only for entities that
support NBMA interfaces over ATM."
GROUP juniAtmTrafficShapingGroup
DESCRIPTION
"The juniAtmTrafficShapingGroup is mandatory only for entities
that support ATM traffic shaping."
GROUP juniAtmPnniGroup
DESCRIPTION
"The juniAtmPnniGroup is mandatory only for entities that
support PNNI routing for ATM networks."
GROUP juniAtmLocationGroup
DESCRIPTION
"The juniAtmLocationGroup is mandatory only for entities that
support slot and port interface location information"
GROUP juniAtmMartiniGroup
DESCRIPTION
"The juniAtmMartiniGroup is mandatory only for entities that
support ATM Martini cell aggregation configuration"
::= { juniAtmCompliances 11 } -- JUNOSe 6.1
juniAtmCompliance12 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for entities which implement the Juniper ATM
MIB. This statement became obsolete when juniAtmVpStatsGroup was added."
MODULE -- this module
MANDATORY-GROUPS {
juniAtmGroup8,
juniAtmAal5Group,
juniAtmSubIfGroup5,
juniAtmVpPingControlGroup,
juniAtmVcPingControlGroup,
juniAtmPingTrapGroup,
juniAtmSvcGroup2,
juniAtmF4OamCircuitGroup }
GROUP juniAtmVpTunnelGroup
DESCRIPTION
"The juniAtmVpTunnelGroup is mandatory only for entities that
support a VP Tunnel functionality."
GROUP juniAtmNbmaMapGroup
DESCRIPTION
"The juniAtmNbmaMapGroup is mandatory only for entities that
support NBMA interfaces over ATM."
GROUP juniAtmTrafficShapingGroup
DESCRIPTION
"The juniAtmTrafficShapingGroup is mandatory only for entities
that support ATM traffic shaping."
GROUP juniAtmPnniGroup
DESCRIPTION
"The juniAtmPnniGroup is mandatory only for entities that
support PNNI routing for ATM networks."
GROUP juniAtmLocationGroup
DESCRIPTION
"The juniAtmLocationGroup is mandatory only for entities that
support slot and port interface location information"
GROUP juniAtmMartiniGroup
DESCRIPTION
"The juniAtmMartiniGroup is mandatory only for entities that
support ATM Martini cell aggregation configuration"
::= { juniAtmCompliances 12 } -- JUNOSe 7.0
juniAtmCompliance13 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for entities which implement the Juniper ATM
MIB. This statement became obsolete when SVC support was removed."
MODULE -- this module
MANDATORY-GROUPS {
juniAtmGroup8,
juniAtmAal5Group,
juniAtmSubIfGroup6,
juniAtmVpPingControlGroup,
juniAtmVcPingControlGroup,
juniAtmPingTrapGroup,
juniAtmSvcGroup2,
juniAtmF4OamCircuitGroup2,
juniAtmVpStatsGroup }
GROUP juniAtmVpTunnelGroup
DESCRIPTION
"The juniAtmVpTunnelGroup is mandatory only for entities that
support a VP Tunnel functionality."
GROUP juniAtmNbmaMapGroup
DESCRIPTION
"The juniAtmNbmaMapGroup is mandatory only for entities that
support NBMA interfaces over ATM."
GROUP juniAtmTrafficShapingGroup
DESCRIPTION
"The juniAtmTrafficShapingGroup is mandatory only for entities
that support ATM traffic shaping."
GROUP juniAtmPnniGroup
DESCRIPTION
"The juniAtmPnniGroup is mandatory only for entities that
support PNNI routing for ATM networks."
GROUP juniAtmLocationGroup
DESCRIPTION
"The juniAtmLocationGroup is mandatory only for entities that
support slot and port interface location information"
GROUP juniAtmMartiniGroup
DESCRIPTION
"The juniAtmMartiniGroup is mandatory only for entities that
support ATM Martini cell aggregation configuration"
::= { juniAtmCompliances 13 } -- JUNOSe 7.1
juniAtmCompliance14 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which implement the Juniper ATM
MIB."
MODULE -- this module
MANDATORY-GROUPS {
juniAtmGroup9,
juniAtmAal5Group,
juniAtmSubIfGroup7,
juniAtmVpPingControlGroup,
juniAtmVcPingControlGroup,
juniAtmPingTrapGroup,
juniAtmSvcGroup2,
juniAtmF4OamCircuitGroup2,
juniAtmVpStatsGroup,
juniAtmVcClassGroup}
GROUP juniAtmVpTunnelGroup
DESCRIPTION
"The juniAtmVpTunnelGroup is mandatory only for entities that
support a VP Tunnel functionality."
GROUP juniAtmNbmaMapGroup
DESCRIPTION
"The juniAtmNbmaMapGroup is mandatory only for entities that
support NBMA interfaces over ATM."
GROUP juniAtmTrafficShapingGroup
DESCRIPTION
"The juniAtmTrafficShapingGroup is mandatory only for entities
that support ATM traffic shaping."
GROUP juniAtmPnniGroup
DESCRIPTION
"The juniAtmPnniGroup is mandatory only for entities that
support PNNI routing for ATM networks."
GROUP juniAtmLocationGroup
DESCRIPTION
"The juniAtmLocationGroup is mandatory only for entities that
support slot and port interface location information"
GROUP juniAtmMartiniGroup
DESCRIPTION
"The juniAtmMartiniGroup is mandatory only for entities that
support ATM Martini cell aggregation configuration"
GROUP juniAtmVcClassGroup
DESCRIPTION
"The juniAtmVcClassGroup is mandatory only for entities that
support ATM VC class configuration"
::= { juniAtmCompliances 14 } -- JUNOSe 7.3
--
-- units of conformance
--
juniAtmGroup OBJECT-GROUP
OBJECTS {
juniAtmNextIfIndex,
juniAtmIfRowStatus,
juniAtmIfLowerIfIndex,
juniAtmIfIlmiVpi,
juniAtmIfIlmiVci,
juniAtmIfIlmiVcd,
juniAtmIfIlmiPollFrequency,
juniAtmIfIlmiAdminState,
juniAtmIfUniVersion,
juniAtmIfOamCellRxAdminState,
juniAtmIfInCells,
juniAtmIfOutCells,
juniAtmIfVcCount,
juniAtmPvcStatsInCells,
juniAtmPvcStatsInCellOctets,
juniAtmPvcStatsInPackets,
juniAtmPvcStatsInPacketOctets,
juniAtmPvcStatsOutCells,
juniAtmPvcStatsOutCellOctets,
juniAtmPvcStatsOutPackets,
juniAtmPvcStatsOutPacketOctets,
juniAtmPvcStatsInCellErrors,
juniAtmPvcStatsinPacketErrors,
juniAtmPvcStatsOutCellErrors,
juniAtmPvcStatsOutPacketErrors,
juniAtmPvcStatsInPacketDiscards,
juniAtmPvcStatsInPacketOctetDiscards,
juniAtmIfCapabilityTrafficShaping,
juniAtmIfCapabilityOam,
juniAtmIfCapabilityDefaultVcPerVp,
juniAtmIfCapabilityNumVpiVciBits,
juniAtmIfCapabilityMaxVcd,
juniAtmIfCapabilityMaxVpi,
juniAtmIfCapabilityMaxVci }
STATUS obsolete
DESCRIPTION
"Obsolete collection of objects providing management of ATM interfaces
in a Juniper product. This group became obsolete when the
juniAtmIfMapGroup object was added."
::= { juniAtmGroups 1 } -- JUNOSe 3.0
juniAtmAal5Group OBJECT-GROUP
OBJECTS {
juniAtmAal5NextIfIndex,
juniAtmAal5IfRowStatus,
juniAtmAal5IfLowerIfIndex }
STATUS current
DESCRIPTION
"A collection of objects providing management of AAL5 interfaces in a
Juniper product."
::= { juniAtmGroups 2 } -- JUNOSe 3.0
juniAtmSubIfGroup OBJECT-GROUP
OBJECTS {
juniAtmSubIfNextIfIndex,
juniAtmSubIfRowStatus,
juniAtmSubIfDistinguisher,
juniAtmSubIfLowerIfIndex,
juniAtmSubIfVccRowStatus,
juniAtmSubIfVccVcd,
juniAtmSubIfVccType,
juniAtmSubIfVccServiceCategory,
juniAtmSubIfVccPcr,
juniAtmSubIfVccScr,
juniAtmSubIfVccMbs,
juniAtmCircuitOamAdminStatus,
juniAtmCircuitOamLoopbackOperStatus,
juniAtmCircuitVcOamOperStatus,
juniAtmCircuitOamLoopbackFrequency,
juniAtmCircuitInOamF5Cells,
juniAtmCircuitInOamCellsDropped,
juniAtmCircuitOutOamF5Cells,
juniAtmCircuitInOamF5EndToEndLoopbackCells,
juniAtmCircuitInOamF5SegmentLoopbackCells,
juniAtmCircuitInOamF5AisCells,
juniAtmCircuitInOamF5RdiCells,
juniAtmCircuitOutOamF5EndToEndLoopbackCells,
juniAtmCircuitOutOamF5SegmentLoopbackCells,
juniAtmCircuitOutOamF5RdiCells }
STATUS obsolete
DESCRIPTION
"Obsolete collection of objects providing management of ATM
subinterfaces in a Juniper product. This group became obsolete when
juniAtmSubIfNbma, juniAtmSubIfInverseArp, and
juniAtmSubIfInverseArpRefresh were added."
::= { juniAtmGroups 3 } -- JUNOSe 3.0
juniAtmVpTunnelGroup OBJECT-GROUP
OBJECTS {
juniAtmVpTunnelKbps,
juniAtmVpTunnelRowStatus,
juniAtmVpTunnelServiceCategory }
STATUS current
DESCRIPTION
"A collection of objects providing management of VP tunnels in a Juniper
product."
::= { juniAtmGroups 4 } -- JUNOSe 3.0
juniAtmNbmaMapGroup OBJECT-GROUP
OBJECTS {
juniAtmNbmaMapIpAddress,
juniAtmNbmaMapVpi,
juniAtmNbmaMapVci,
juniAtmNbmaMapIfIndex,
juniAtmNbmaMapBroadcast,
juniAtmNbmaMapRowStatus,
juniAtmNbmaMapListRowStatus }
STATUS current
DESCRIPTION
"A collection of object providing management of NBMA in a Juniper
product."
::= { juniAtmGroups 5 } -- JUNOSe 3.2
juniAtmSubIfGroup2 OBJECT-GROUP
OBJECTS {
juniAtmSubIfNextIfIndex,
juniAtmSubIfRowStatus,
juniAtmSubIfDistinguisher,
juniAtmSubIfLowerIfIndex,
juniAtmSubIfNbma,
juniAtmSubIfVccRowStatus,
juniAtmSubIfVccVcd,
juniAtmSubIfVccType,
juniAtmSubIfVccServiceCategory,
juniAtmSubIfVccPcr,
juniAtmSubIfVccScr,
juniAtmSubIfVccMbs,
juniAtmSubIfInverseArp,
juniAtmSubIfInverseArpRefresh,
juniAtmCircuitOamAdminStatus,
juniAtmCircuitOamLoopbackOperStatus,
juniAtmCircuitVcOamOperStatus,
juniAtmCircuitOamLoopbackFrequency,
juniAtmCircuitInOamF5Cells,
juniAtmCircuitInOamCellsDropped,
juniAtmCircuitOutOamF5Cells,
juniAtmCircuitInOamF5EndToEndLoopbackCells,
juniAtmCircuitInOamF5SegmentLoopbackCells,
juniAtmCircuitInOamF5AisCells,
juniAtmCircuitInOamF5RdiCells,
juniAtmCircuitOutOamF5EndToEndLoopbackCells,
juniAtmCircuitOutOamF5SegmentLoopbackCells,
juniAtmCircuitOutOamF5RdiCells }
STATUS obsolete
DESCRIPTION
"Obsolete collection of objects providing management of ATM
subinterfaces in a Juniper product. This group became obsolete when
juniAtmSubIfAddress was added."
::= { juniAtmGroups 6 } -- JUNOSe 3.2
juniAtmVpPingControlGroup OBJECT-GROUP
OBJECTS {
juniAtmVpPingProbeCount,
juniAtmVpPingTimeOut,
juniAtmVpPingCtlTrapGeneration,
juniAtmVpPingSentProbes,
juniAtmVpPingProbeResponses,
juniAtmVpPingStartTime,
juniAtmVpPingMinRtt,
juniAtmVpPingMaxRtt,
juniAtmVpPingAverageRtt }
STATUS current
DESCRIPTION
"A collection of object providing management of ATM VPL Ping testing in
a Juniper product."
::= { juniAtmGroups 7 } -- JUNOSe 3.2
juniAtmVcPingControlGroup OBJECT-GROUP
OBJECTS {
juniAtmVcPingProbeCount,
juniAtmVcPingTimeOut,
juniAtmVcPingCtlTrapGeneration,
juniAtmVcPingSentProbes,
juniAtmVcPingProbeResponses,
juniAtmVcPingStartTime,
juniAtmVcPingMinRtt,
juniAtmVcPingMaxRtt,
juniAtmVcPingAverageRtt }
STATUS current
DESCRIPTION
"A collection of object providing management of ATM VCL Ping testing in
a Juniper product."
::= { juniAtmGroups 8 } -- JUNOSe 3.2
juniAtmPingTrapGroup NOTIFICATION-GROUP
NOTIFICATIONS {
juniAtmVpPingTestCompleted,
juniAtmVcPingTestCompleted }
STATUS current
DESCRIPTION
"A collection of notifications supporting ATM Ping testing in a Juniper
product."
::= { juniAtmGroups 9 } -- JUNOSe 3.2
juniAtmGroup2 OBJECT-GROUP
OBJECTS {
juniAtmNextIfIndex,
juniAtmIfRowStatus,
juniAtmIfLowerIfIndex,
juniAtmIfIlmiVpi,
juniAtmIfIlmiVci,
juniAtmIfIlmiVcd,
juniAtmIfIlmiPollFrequency,
juniAtmIfIlmiAdminState,
juniAtmIfUniVersion,
juniAtmIfOamCellRxAdminState,
juniAtmIfInCells,
juniAtmIfOutCells,
juniAtmIfVcCount,
juniAtmIfMapGroup,
juniAtmIfOamCellFilter,
juniAtmPvcStatsInCells,
juniAtmPvcStatsInCellOctets,
juniAtmPvcStatsInPackets,
juniAtmPvcStatsInPacketOctets,
juniAtmPvcStatsOutCells,
juniAtmPvcStatsOutCellOctets,
juniAtmPvcStatsOutPackets,
juniAtmPvcStatsOutPacketOctets,
juniAtmPvcStatsInCellErrors,
juniAtmPvcStatsinPacketErrors,
juniAtmPvcStatsOutCellErrors,
juniAtmPvcStatsOutPacketErrors,
juniAtmPvcStatsInPacketDiscards,
juniAtmPvcStatsInPacketOctetDiscards,
juniAtmPvcStatsInPacketUnknownProtocol,
juniAtmIfCapabilityTrafficShaping,
juniAtmIfCapabilityOam,
juniAtmIfCapabilityDefaultVcPerVp,
juniAtmIfCapabilityNumVpiVciBits,
juniAtmIfCapabilityMaxVcd,
juniAtmIfCapabilityMaxVpi,
juniAtmIfCapabilityMaxVci,
juniAtmIfCapabilityOamCellFilter }
STATUS obsolete
DESCRIPTION
"Obsolete collection of objects providing management of ATM interfaces
in a Juniper product. This group became obsolete when support was
added for connection admission control (CAC)."
::= { juniAtmGroups 10 } -- JUNOSe 3.2
juniAtmTrafficShapingGroup OBJECT-GROUP
OBJECTS {
juniAtmSubIfVccTrafficShapingCdvt,
juniAtmSubIfVccTrafficShapingClp0,
juniAtmSubIfVccTrafficShapingTagging,
juniAtmSubIfVccTrafficShapingPoliceObserve,
juniAtmSubIfVccTrafficShapingPacketShaping }
STATUS current
DESCRIPTION
"A collection of objects providing management of ATM traffic shaping in
a Juniper product."
::= { juniAtmGroups 11 } -- JUNOSe 3.3
juniAtmGroup3 OBJECT-GROUP
OBJECTS {
juniAtmNextIfIndex,
juniAtmIfRowStatus,
juniAtmIfLowerIfIndex,
juniAtmIfIlmiVpi,
juniAtmIfIlmiVci,
juniAtmIfIlmiVcd,
juniAtmIfIlmiPollFrequency,
juniAtmIfIlmiAdminState,
juniAtmIfUniVersion,
juniAtmIfOamCellRxAdminState,
juniAtmIfInCells,
juniAtmIfOutCells,
juniAtmIfVcCount,
juniAtmIfMapGroup,
juniAtmIfCacAdminState,
juniAtmIfCacUbrWeight,
juniAtmIfCacSubscriptionBandwidth,
juniAtmIfCacAvailableBandwidth,
juniAtmIfOamCellFilter,
juniAtmPvcStatsInCells,
juniAtmPvcStatsInCellOctets,
juniAtmPvcStatsInPackets,
juniAtmPvcStatsInPacketOctets,
juniAtmPvcStatsOutCells,
juniAtmPvcStatsOutCellOctets,
juniAtmPvcStatsOutPackets,
juniAtmPvcStatsOutPacketOctets,
juniAtmPvcStatsInCellErrors,
juniAtmPvcStatsinPacketErrors,
juniAtmPvcStatsOutCellErrors,
juniAtmPvcStatsOutPacketErrors,
juniAtmPvcStatsInPacketDiscards,
juniAtmPvcStatsInPacketOctetDiscards,
juniAtmPvcStatsInPacketUnknownProtocol,
juniAtmIfCapabilityTrafficShaping,
juniAtmIfCapabilityOam,
juniAtmIfCapabilityDefaultVcPerVp,
juniAtmIfCapabilityNumVpiVciBits,
juniAtmIfCapabilityMaxVcd,
juniAtmIfCapabilityMaxVpi,
juniAtmIfCapabilityMaxVci,
juniAtmIfCapabilityOamCellFilter }
STATUS obsolete
DESCRIPTION
"Obsolete collection of objects providing management of ATM interfaces
in a Juniper product. This group became obsolete when support was added
for connection admission control (CAC) used bandwidth."
::= { juniAtmGroups 12 } -- JUNOSe 3.4
juniAtmGroup4 OBJECT-GROUP
OBJECTS {
juniAtmNextIfIndex,
juniAtmIfRowStatus,
juniAtmIfLowerIfIndex,
juniAtmIfIlmiVpi,
juniAtmIfIlmiVci,
juniAtmIfIlmiVcd,
juniAtmIfIlmiPollFrequency,
juniAtmIfIlmiAdminState,
juniAtmIfUniVersion,
juniAtmIfOamCellRxAdminState,
juniAtmIfInCells,
juniAtmIfOutCells,
juniAtmIfVcCount,
juniAtmIfMapGroup,
juniAtmIfCacAdminState,
juniAtmIfCacUbrWeight,
juniAtmIfCacSubscriptionBandwidth,
juniAtmIfCacAvailableBandwidth,
juniAtmIfOamCellFilter,
juniAtmIfCacUsedBandwidthUpper,
juniAtmIfCacUsedBandwidthLower,
juniAtmPvcStatsInCells,
juniAtmPvcStatsInCellOctets,
juniAtmPvcStatsInPackets,
juniAtmPvcStatsInPacketOctets,
juniAtmPvcStatsOutCells,
juniAtmPvcStatsOutCellOctets,
juniAtmPvcStatsOutPackets,
juniAtmPvcStatsOutPacketOctets,
juniAtmPvcStatsInCellErrors,
juniAtmPvcStatsinPacketErrors,
juniAtmPvcStatsOutCellErrors,
juniAtmPvcStatsOutPacketErrors,
juniAtmPvcStatsInPacketDiscards,
juniAtmPvcStatsInPacketOctetDiscards,
juniAtmPvcStatsInPacketUnknownProtocol,
juniAtmIfCapabilityTrafficShaping,
juniAtmIfCapabilityOam,
juniAtmIfCapabilityDefaultVcPerVp,
juniAtmIfCapabilityNumVpiVciBits,
juniAtmIfCapabilityMaxVcd,
juniAtmIfCapabilityMaxVpi,
juniAtmIfCapabilityMaxVci,
juniAtmIfCapabilityOamCellFilter }
STATUS obsolete
DESCRIPTION
"Obsolete collection of objects providing management of ATM interfaces
in a Juniper product. This group became obsolete when CAC recieve
bandwith and E164 public addressing objects were added."
::= { juniAtmGroups 13 } -- JUNOSe 4.0
juniAtmSvcGroup OBJECT-GROUP
OBJECTS {
juniAtmIfSvcSignallingVpi,
juniAtmIfSvcSignallingVci,
juniAtmIfSvcSignallingVcd,
juniAtmIfSvcSignallingAdminStatus,
juniAtmSubIfSvcRowStatus,
juniAtmSubIfSvcConfigDestAtmAddress,
juniAtmSubIfSvcConfigCircuitType,
juniAtmSubIfSvcConfigServiceCategory,
juniAtmSubIfSvcConfigPcr,
juniAtmSubIfSvcConfigScr,
juniAtmSubIfSvcConfigMbs,
juniAtmSubIfSvcConfigCdvt,
juniAtmSubIfSvcConfigClp0,
juniAtmSubIfSvcConfigTagging,
juniAtmSubIfSvcConfigObserve,
juniAtmSubIfSvcConfigPacketDiscard }
STATUS obsolete
DESCRIPTION
"Obsolete collection of objects providing management of ATM SVC
interfaces in a Juniper product. This group became obsolete when E164
public addressing support was added."
::= { juniAtmGroups 14 } -- JUNOSe 4.0
juniAtmSubIfGroup3 OBJECT-GROUP
OBJECTS {
juniAtmSubIfNextIfIndex,
juniAtmSubIfRowStatus,
juniAtmSubIfDistinguisher,
juniAtmSubIfLowerIfIndex,
juniAtmSubIfNbma,
juniAtmSubIfAddress,
juniAtmSubIfVccRowStatus,
juniAtmSubIfVccVcd,
juniAtmSubIfVccType,
juniAtmSubIfVccServiceCategory,
juniAtmSubIfVccPcr,
juniAtmSubIfVccScr,
juniAtmSubIfVccMbs,
juniAtmSubIfInverseArp,
juniAtmSubIfInverseArpRefresh,
juniAtmCircuitOamAdminStatus,
juniAtmCircuitOamLoopbackOperStatus,
juniAtmCircuitVcOamOperStatus,
juniAtmCircuitOamLoopbackFrequency,
juniAtmCircuitInOamF5Cells,
juniAtmCircuitInOamCellsDropped,
juniAtmCircuitOutOamF5Cells,
juniAtmCircuitInOamF5EndToEndLoopbackCells,
juniAtmCircuitInOamF5SegmentLoopbackCells,
juniAtmCircuitInOamF5AisCells,
juniAtmCircuitInOamF5RdiCells,
juniAtmCircuitOutOamF5EndToEndLoopbackCells,
juniAtmCircuitOutOamF5SegmentLoopbackCells,
juniAtmCircuitOutOamF5RdiCells }
STATUS obsolete
DESCRIPTION
"Obsolete collection of objects providing management of ATM
subinterfaces in a Juniper product. This group became obsolete when
juniAtmSubIfMtu was added."
::= { juniAtmGroups 15 } -- JUNOSe 4.0
juniAtmGroup5 OBJECT-GROUP
OBJECTS {
juniAtmNextIfIndex,
juniAtmIfRowStatus,
juniAtmIfLowerIfIndex,
juniAtmIfIlmiVpi,
juniAtmIfIlmiVci,
juniAtmIfIlmiVcd,
juniAtmIfIlmiPollFrequency,
juniAtmIfIlmiAdminState,
juniAtmIfUniVersion,
juniAtmIfOamCellRxAdminState,
juniAtmIfInCells,
juniAtmIfOutCells,
juniAtmIfVcCount,
juniAtmIfMapGroup,
juniAtmIfCacAdminState,
juniAtmIfCacUbrWeight,
juniAtmIfCacSubscriptionBandwidth,
juniAtmIfCacAvailableBandwidth,
juniAtmIfCacAvailableBandwidthRx,
juniAtmIfE164Autoconversion,
juniAtmIfE164Gateway,
juniAtmIfE164OneToOneAddrTrans,
juniAtmPvcStatsInCells,
juniAtmPvcStatsInCellOctets,
juniAtmPvcStatsInPackets,
juniAtmPvcStatsInPacketOctets,
juniAtmPvcStatsOutCells,
juniAtmPvcStatsOutCellOctets,
juniAtmPvcStatsOutPackets,
juniAtmPvcStatsOutPacketOctets,
juniAtmPvcStatsInCellErrors,
juniAtmPvcStatsinPacketErrors,
juniAtmPvcStatsOutCellErrors,
juniAtmPvcStatsOutPacketErrors,
juniAtmPvcStatsInPacketDiscards,
juniAtmPvcStatsInPacketOctetDiscards,
juniAtmPvcStatsInPacketUnknownProtocol,
juniAtmIfCapabilityTrafficShaping,
juniAtmIfCapabilityOam,
juniAtmIfCapabilityDefaultVcPerVp,
juniAtmIfCapabilityNumVpiVciBits,
juniAtmIfCapabilityMaxVcd,
juniAtmIfCapabilityMaxVpi,
juniAtmIfCapabilityMaxVci }
STATUS obsolete
DESCRIPTION
"Obsolete collection of objects providing management of ATM interfaces
in a Juniper product. This group became obsolete when ATM VP
description support was added."
::= { juniAtmGroups 16 } -- JUNOSe 4.1
juniAtmSvcGroup2 OBJECT-GROUP
OBJECTS {
juniAtmIfSvcSignallingVpi,
juniAtmIfSvcSignallingVci,
juniAtmIfSvcSignallingVcd,
juniAtmIfSvcSignallingAdminStatus,
juniAtmSubIfSvcRowStatus,
juniAtmSubIfSvcConfigDestAtmAddress,
juniAtmSubIfSvcConfigCircuitType,
juniAtmSubIfSvcConfigServiceCategory,
juniAtmSubIfSvcConfigPcr,
juniAtmSubIfSvcConfigScr,
juniAtmSubIfSvcConfigMbs,
juniAtmSubIfSvcConfigClp0,
juniAtmSubIfSvcConfigTagging,
juniAtmSubIfSvcConfigPacketDiscard,
juniAtmSubIfSvcConfigDestE164Address }
STATUS current
DESCRIPTION
"A collection of objects providing management of ATM SVC interfaces in a
Juniper product."
::= { juniAtmGroups 17 } -- JUNOSe 4.1
juniAtmPnniGroup OBJECT-GROUP
OBJECTS {
juniAtmIfPnniRccVpi,
juniAtmIfPnniRccVci,
juniAtmIfPnniRccVcd,
juniAtmIfPnniRccAdminStatus }
STATUS current
DESCRIPTION
"A collection of objects providing management of PNNI Routing Control
Channels in a Juniper product."
::= { juniAtmGroups 18 } -- JUNOSe 4.1
juniAtmSubIfGroup4 OBJECT-GROUP
OBJECTS {
juniAtmSubIfNextIfIndex,
juniAtmSubIfRowStatus,
juniAtmSubIfDistinguisher,
juniAtmSubIfLowerIfIndex,
juniAtmSubIfNbma,
juniAtmSubIfAddress,
juniAtmSubIfMtu,
juniAtmSubIfVccRowStatus,
juniAtmSubIfVccVcd,
juniAtmSubIfVccType,
juniAtmSubIfVccServiceCategory,
juniAtmSubIfVccPcr,
juniAtmSubIfVccScr,
juniAtmSubIfVccMbs,
juniAtmSubIfInverseArp,
juniAtmSubIfInverseArpRefresh,
juniAtmCircuitOamAdminStatus,
juniAtmCircuitOamLoopbackOperStatus,
juniAtmCircuitVcOamOperStatus,
juniAtmCircuitOamLoopbackFrequency,
juniAtmCircuitInOamF5Cells,
juniAtmCircuitInOamCellsDropped,
juniAtmCircuitOutOamF5Cells,
juniAtmCircuitInOamF5EndToEndLoopbackCells,
juniAtmCircuitInOamF5SegmentLoopbackCells,
juniAtmCircuitInOamF5AisCells,
juniAtmCircuitInOamF5RdiCells,
juniAtmCircuitOutOamF5EndToEndLoopbackCells,
juniAtmCircuitOutOamF5SegmentLoopbackCells,
juniAtmCircuitOutOamF5RdiCells }
STATUS obsolete
DESCRIPTION
"Obsolete collection of objects providing management of ATM
subinterfaces in a Juniper product. This group became obsolete when
support was added to export the subinterface description to the line
cards."
::= { juniAtmGroups 19 } -- JUNOSe 4.1
juniAtmF4OamCircuitGroup OBJECT-GROUP
OBJECTS {
-- End-to-end configs
juniAtmOamF4FlowEndToEndLoopbackTimer,
juniAtmOamF4FlowEndToEndCCSink,
juniAtmOamF4FlowEndToEndCCSource,
juniAtmOamF4FlowEndToEndRowStatus,
-- Segment configs
juniAtmOamF4FlowSegmentCCSink,
juniAtmOamF4FlowSegmentCCSource,
juniAtmOamF4FlowSegmentRowStatus,
-- End-to-end stats
juniAtmF4FlowInOamEndAisCells,
juniAtmF4FlowInOamEndRdiCells,
juniAtmF4FlowInOamEndCCCells,
juniAtmF4FlowInOamEndCCActDeActCells,
juniAtmF4FlowInOamEndLoopbackCells,
juniAtmF4FlowOutEndRdiCells,
juniAtmF4FlowOutEndCCCells,
juniAtmF4FlowOutEndCCActDeActCells,
juniAtmF4FlowOutEndToEndLoopbackCells,
juniAtmF4FlowEndActualLoopbackFreq,
juniAtmF4FlowEndLastTimeChanged,
juniAtmF4FlowOamEndVpOperationState,
juniAtmF4FlowOamEndVpAdminState,
juniAtmF4FlowEndInOamCells,
juniAtmF4FlowEndOutOamCells,
juniAtmF4FlowEndInOamCellsDropped,
-- Segment stats
juniAtmF4FlowInOamSegmentAisCells,
juniAtmF4FlowInOamSegmentRdiCells,
juniAtmF4FlowInOamSegmentCCCells,
juniAtmF4FlowInOamSegmentCCActDeActCells,
juniAtmF4FlowInOamSegmentLoopbackCells,
juniAtmF4FlowOutSegmentRdiCells,
juniAtmF4FlowOutSegmentCCCells,
juniAtmF4FlowOutSegmentCCActDeActCells,
juniAtmF4FlowOutSegmentLoopbackCells,
juniAtmF4FlowSegmentLastTimeChanged,
juniAtmF4FlowOamSegmentVpOperationState,
juniAtmF4FlowOamSegmentVpAdminState,
juniAtmF4FlowSegmentInOamCells,
juniAtmF4FlowSegmentOutOamCells,
juniAtmF4FlowSegmentInOamCellsDropped }
STATUS obsolete
DESCRIPTION
"Obsolete collection of objects providing management of ATM F4 flow OAM
circuits in a Juniper product."
::= { juniAtmGroups 20 } -- JUNOSe 4.1
juniAtmGroup6 OBJECT-GROUP
OBJECTS {
juniAtmNextIfIndex,
juniAtmIfRowStatus,
juniAtmIfLowerIfIndex,
juniAtmIfIlmiVpi,
juniAtmIfIlmiVci,
juniAtmIfIlmiVcd,
juniAtmIfIlmiPollFrequency,
juniAtmIfIlmiAdminState,
juniAtmIfUniVersion,
juniAtmIfOamCellRxAdminState,
juniAtmIfInCells,
juniAtmIfOutCells,
juniAtmIfVcCount,
juniAtmIfMapGroup,
juniAtmIfCacAdminState,
juniAtmIfCacUbrWeight,
juniAtmIfCacSubscriptionBandwidth,
juniAtmIfCacAvailableBandwidth,
juniAtmIfCacAvailableBandwidthRx,
juniAtmIfE164Autoconversion,
juniAtmIfE164Gateway,
juniAtmIfE164OneToOneAddrTrans,
juniAtmPvcStatsInCells,
juniAtmPvcStatsInCellOctets,
juniAtmPvcStatsInPackets,
juniAtmPvcStatsInPacketOctets,
juniAtmPvcStatsOutCells,
juniAtmPvcStatsOutCellOctets,
juniAtmPvcStatsOutPackets,
juniAtmPvcStatsOutPacketOctets,
juniAtmPvcStatsInCellErrors,
juniAtmPvcStatsinPacketErrors,
juniAtmPvcStatsOutCellErrors,
juniAtmPvcStatsOutPacketErrors,
juniAtmPvcStatsInPacketDiscards,
juniAtmPvcStatsInPacketOctetDiscards,
juniAtmPvcStatsInPacketUnknownProtocol,
juniAtmIfCapabilityTrafficShaping,
juniAtmIfCapabilityOam,
juniAtmIfCapabilityDefaultVcPerVp,
juniAtmIfCapabilityNumVpiVciBits,
juniAtmIfCapabilityMaxVcd,
juniAtmIfCapabilityMaxVpi,
juniAtmIfCapabilityMaxVci,
juniAtmVpDescription,
juniAtmBulkCircuitsNameRowStatus,
juniAtmBulkCircuitsNameId,
juniAtmBulkCircuitsIdName,
juniAtmBulkCircuitsIdNextInstance,
juniAtmBulkCircuitsRowStatus,
juniAtmBulkCircuitsMinVpi,
juniAtmBulkCircuitsMaxVpi,
juniAtmBulkCircuitsMinVci,
juniAtmBulkCircuitsMaxVci }
STATUS obsolete
DESCRIPTION
"Obsolete collection of objects providing management of ATM interfaces
in a Juniper product. This group became obsolete when bulk-configuration
profile override support was added."
::= { juniAtmGroups 21 } -- JUNOSe 5.1
juniAtmLocationGroup OBJECT-GROUP
OBJECTS {
juniAtmSubIfLocationType,
juniAtmSubIfLocationIfIndex }
STATUS current
DESCRIPTION
"A collection of objects providing interface location information in a
Juniper product."
::= { juniAtmGroups 22 } -- JUNOSe 5.2
juniAtmSubIfGroup5 OBJECT-GROUP
OBJECTS {
juniAtmSubIfNextIfIndex,
juniAtmSubIfRowStatus,
juniAtmSubIfDistinguisher,
juniAtmSubIfLowerIfIndex,
juniAtmSubIfNbma,
juniAtmSubIfAddress,
juniAtmSubIfMtu,
juniAtmSubIfAdvisoryRxSpeed,
juniAtmSubIfVccRowStatus,
juniAtmSubIfVccVcd,
juniAtmSubIfVccType,
juniAtmSubIfVccServiceCategory,
juniAtmSubIfVccPcr,
juniAtmSubIfVccScr,
juniAtmSubIfVccMbs,
juniAtmSubIfInverseArp,
juniAtmSubIfInverseArpRefresh,
juniAtmCircuitOamAdminStatus,
juniAtmCircuitOamLoopbackOperStatus,
juniAtmCircuitVcOamOperStatus,
juniAtmCircuitOamLoopbackFrequency,
juniAtmCircuitInOamF5Cells,
juniAtmCircuitInOamCellsDropped,
juniAtmCircuitOutOamF5Cells,
juniAtmCircuitInOamF5EndToEndLoopbackCells,
juniAtmCircuitInOamF5SegmentLoopbackCells,
juniAtmCircuitInOamF5AisCells,
juniAtmCircuitInOamF5RdiCells,
juniAtmCircuitOutOamF5EndToEndLoopbackCells,
juniAtmCircuitOutOamF5SegmentLoopbackCells,
juniAtmCircuitOutOamF5RdiCells,
juniAtmSubIfDescriptionExport }
STATUS obsolete
DESCRIPTION
"Obsolete collection of objects providing management of ATM
subinterfaces in a Juniper product."
::= { juniAtmGroups 23 }
juniAtmMartiniGroup OBJECT-GROUP
OBJECTS {
juniAtmMartiniTimeoutTimerValue,
juniAtmSubIfMartiniMaxCellsPerPacket,
juniAtmSubIfMartiniTimeoutTimerId }
STATUS current
DESCRIPTION
"A collection of objects providing ATM Martini cell aggregation
configuration."
::= { juniAtmGroups 24 }
juniAtmGroup7 OBJECT-GROUP
OBJECTS {
juniAtmNextIfIndex,
juniAtmIfRowStatus,
juniAtmIfLowerIfIndex,
juniAtmIfIlmiVpi,
juniAtmIfIlmiVci,
juniAtmIfIlmiVcd,
juniAtmIfIlmiPollFrequency,
juniAtmIfIlmiAdminState,
juniAtmIfUniVersion,
juniAtmIfOamCellRxAdminState,
juniAtmIfInCells,
juniAtmIfOutCells,
juniAtmIfVcCount,
juniAtmIfMapGroup,
juniAtmIfCacAdminState,
juniAtmIfCacUbrWeight,
juniAtmIfCacSubscriptionBandwidth,
juniAtmIfCacAvailableBandwidth,
juniAtmIfCacAvailableBandwidthRx,
juniAtmIfE164Autoconversion,
juniAtmIfE164Gateway,
juniAtmIfE164OneToOneAddrTrans,
juniAtmPvcStatsInCells,
juniAtmPvcStatsInCellOctets,
juniAtmPvcStatsInPackets,
juniAtmPvcStatsInPacketOctets,
juniAtmPvcStatsOutCells,
juniAtmPvcStatsOutCellOctets,
juniAtmPvcStatsOutPackets,
juniAtmPvcStatsOutPacketOctets,
juniAtmPvcStatsInCellErrors,
juniAtmPvcStatsinPacketErrors,
juniAtmPvcStatsOutCellErrors,
juniAtmPvcStatsOutPacketErrors,
juniAtmPvcStatsInPacketDiscards,
juniAtmPvcStatsInPacketOctetDiscards,
juniAtmPvcStatsInPacketUnknownProtocol,
juniAtmIfCapabilityTrafficShaping,
juniAtmIfCapabilityOam,
juniAtmIfCapabilityDefaultVcPerVp,
juniAtmIfCapabilityNumVpiVciBits,
juniAtmIfCapabilityMaxVcd,
juniAtmIfCapabilityMaxVpi,
juniAtmIfCapabilityMaxVci,
juniAtmVpDescription,
juniAtmBulkCircuitsNameRowStatus,
juniAtmBulkCircuitsNameId,
juniAtmBulkCircuitsIdName,
juniAtmBulkCircuitsIdNextInstance,
juniAtmBulkCircuitsRowStatus,
juniAtmBulkCircuitsMinVpi,
juniAtmBulkCircuitsMaxVpi,
juniAtmBulkCircuitsMinVci,
juniAtmBulkCircuitsMaxVci,
juniAtmBulkCircuitsAdminState,
juniAtmProfileOverrideAssignIfCircuitRowStatus,
juniAtmProfileOverrideAssignIfCircuitProfileId,
juniAtmProfileOverrideAssignIfCircuitOperStatus }
STATUS obsolete
DESCRIPTION
"Obsolete collection of objects providing management of ATM
interfaces in a Juniper product."
::= { juniAtmGroups 25 } -- JUNOSe 6.1
juniAtmGroup8 OBJECT-GROUP
OBJECTS {
juniAtmNextIfIndex,
juniAtmIfRowStatus,
juniAtmIfLowerIfIndex,
juniAtmIfIlmiVpi,
juniAtmIfIlmiVci,
juniAtmIfIlmiVcd,
juniAtmIfIlmiPollFrequency,
juniAtmIfIlmiAdminState,
juniAtmIfUniVersion,
juniAtmIfOamCellRxAdminState,
juniAtmIfInCells,
juniAtmIfOutCells,
juniAtmIfVcCount,
juniAtmIfMapGroup,
juniAtmIfCacAdminState,
juniAtmIfCacUbrWeight,
juniAtmIfCacSubscriptionBandwidth,
juniAtmIfCacAvailableBandwidth,
juniAtmPvcStatsInCells,
juniAtmPvcStatsInCellOctets,
juniAtmPvcStatsInPackets,
juniAtmPvcStatsInPacketOctets,
juniAtmPvcStatsOutCells,
juniAtmPvcStatsOutCellOctets,
juniAtmPvcStatsOutPackets,
juniAtmPvcStatsOutPacketOctets,
juniAtmPvcStatsInCellErrors,
juniAtmPvcStatsinPacketErrors,
juniAtmPvcStatsOutCellErrors,
juniAtmPvcStatsOutPacketErrors,
juniAtmPvcStatsInPacketDiscards,
juniAtmPvcStatsInPacketOctetDiscards,
juniAtmPvcStatsInPacketUnknownProtocol,
juniAtmIfCapabilityTrafficShaping,
juniAtmIfCapabilityOam,
juniAtmIfCapabilityDefaultVcPerVp,
juniAtmIfCapabilityNumVpiVciBits,
juniAtmIfCapabilityMaxVcd,
juniAtmIfCapabilityMaxVpi,
juniAtmIfCapabilityMaxVci,
juniAtmVpDescription,
juniAtmBulkCircuitsNameRowStatus,
juniAtmBulkCircuitsNameId,
juniAtmBulkCircuitsIdName,
juniAtmBulkCircuitsIdNextInstance,
juniAtmBulkCircuitsRowStatus,
juniAtmBulkCircuitsMinVpi,
juniAtmBulkCircuitsMaxVpi,
juniAtmBulkCircuitsMinVci,
juniAtmBulkCircuitsMaxVci,
juniAtmBulkCircuitsAdminState,
juniAtmProfileOverrideAssignIfCircuitRowStatus,
juniAtmProfileOverrideAssignIfCircuitProfileId,
juniAtmProfileOverrideAssignIfCircuitOperStatus }
STATUS obsolete
DESCRIPTION
"A collection of objects providing management of ATM interfaces in a
Juniper product."
::= { juniAtmGroups 26 } -- JUNOSe 7.0
juniAtmVpStatsGroup OBJECT-GROUP
OBJECTS {
juniAtmVpStatsInCells,
juniAtmVpStatsInPackets,
juniAtmVpStatsInPacketOctets,
juniAtmVpStatsOutCells,
juniAtmVpStatsOutPackets,
juniAtmVpStatsOutPacketOctets,
juniAtmVpStatsInPacketErrors,
juniAtmVpStatsOutPacketErrors,
juniAtmVpStatsInPacketDiscards,
juniAtmVpStatsInPacketOctetDiscards,
juniAtmVpStatsInPacketUnknownProtocol,
juniAtmVpStatsCrcErrors,
juniAtmVpStatsSarTimeouts,
juniAtmVpStatsOverSizedPackets}
STATUS current
DESCRIPTION
"A collection of objects providing ATM VP level statistics."
::= { juniAtmGroups 27 } -- JUNOSe 7.1
juniAtmSubIfGroup6 OBJECT-GROUP
OBJECTS {
juniAtmSubIfNextIfIndex,
juniAtmSubIfRowStatus,
juniAtmSubIfDistinguisher,
juniAtmSubIfLowerIfIndex,
juniAtmSubIfNbma,
juniAtmSubIfAddress,
juniAtmSubIfMtu,
juniAtmSubIfAdvisoryRxSpeed,
juniAtmSubIfVccRowStatus,
juniAtmSubIfVccVcd,
juniAtmSubIfVccType,
juniAtmSubIfVccServiceCategory,
juniAtmSubIfVccPcr,
juniAtmSubIfVccScr,
juniAtmSubIfVccMbs,
juniAtmSubIfInverseArp,
juniAtmSubIfInverseArpRefresh,
juniAtmCircuitOamAdminStatus,
juniAtmCircuitOamLoopbackOperStatus,
juniAtmCircuitVcOamOperStatus,
juniAtmCircuitOamLoopbackFrequency,
juniAtmCircuitInOamF5Cells,
juniAtmCircuitInOamCellsDropped,
juniAtmCircuitOutOamF5Cells,
juniAtmCircuitInOamF5EndToEndLoopbackCells,
juniAtmCircuitInOamF5SegmentLoopbackCells,
juniAtmCircuitInOamF5AisCells,
juniAtmCircuitInOamF5RdiCells,
juniAtmCircuitOutOamF5EndToEndLoopbackCells,
juniAtmCircuitOutOamF5SegmentLoopbackCells,
juniAtmCircuitOutOamF5RdiCells,
juniAtmCircuitInOamF5EndToEndLoopbackCmds,
juniAtmCircuitInOamF5EndToEndLoopbackRsps,
juniAtmCircuitInOamF5SegmentLoopbackCmds,
juniAtmCircuitInOamF5SegmentLoopbackRsps,
juniAtmCircuitOutOamF5EndToEndLoopbackCmds,
juniAtmCircuitOutOamF5EndToEndLoopbackRsps,
juniAtmCircuitOutOamF5SegmentLoopbackCmds,
juniAtmCircuitOutOamF5SegmentLoopbackRsps,
juniAtmCircuitOamUpCount,
juniAtmCircuitOamDownCount,
juniAtmCircuitOamRetryFrequency,
juniAtmCircuitOamAlarmDownCount,
juniAtmCircuitOamAlarmClearTimeout,
juniAtmSubIfDescriptionExport }
STATUS obsolete
DESCRIPTION
"Obsolete collection of objects providing management of ATM
subinterfaces in a Juniper product. This group became obsolete
when ATM SVC support was removed."
::= { juniAtmGroups 28 } -- JUNOSe 7.1
juniAtmF4OamCircuitGroup2 OBJECT-GROUP
OBJECTS {
juniAtmOamF4FlowEndToEndLoopbackTimer,
juniAtmOamF4FlowEndToEndCCSink,
juniAtmOamF4FlowEndToEndCCSource,
juniAtmOamF4FlowEndToEndRowStatus,
juniAtmOamF4FlowSegmentCCSink,
juniAtmOamF4FlowSegmentCCSource,
juniAtmOamF4FlowSegmentRowStatus,
juniAtmF4FlowInOamEndAisCells,
juniAtmF4FlowInOamEndRdiCells,
juniAtmF4FlowInOamEndCCCells,
juniAtmF4FlowInOamEndCCActDeActCells,
juniAtmF4FlowInOamEndLoopbackCells,
juniAtmF4FlowOutEndRdiCells,
juniAtmF4FlowOutEndCCCells,
juniAtmF4FlowOutEndCCActDeActCells,
juniAtmF4FlowOutEndToEndLoopbackCells,
juniAtmF4FlowEndActualLoopbackFreq,
juniAtmF4FlowEndLastTimeChanged,
juniAtmF4FlowOamEndVpOperationState,
juniAtmF4FlowOamEndVpAdminState,
juniAtmF4FlowEndInOamCells,
juniAtmF4FlowEndOutOamCells,
juniAtmF4FlowEndInOamCellsDropped,
juniAtmF4FlowInOamSegmentAisCells,
juniAtmF4FlowInOamSegmentRdiCells,
juniAtmF4FlowInOamSegmentCCCells,
juniAtmF4FlowInOamSegmentCCActDeActCells,
juniAtmF4FlowInOamSegmentLoopbackCells,
juniAtmF4FlowOutSegmentRdiCells,
juniAtmF4FlowOutSegmentCCCells,
juniAtmF4FlowOutSegmentCCActDeActCells,
juniAtmF4FlowOutSegmentLoopbackCells,
juniAtmF4FlowSegmentLastTimeChanged,
juniAtmF4FlowOamSegmentVpOperationState,
juniAtmF4FlowOamSegmentVpAdminState,
juniAtmF4FlowSegmentInOamCells,
juniAtmF4FlowSegmentOutOamCells,
juniAtmF4FlowSegmentInOamCellsDropped,
juniAtmF4FlowEndToEndInLoopbackCmds,
juniAtmF4FlowEndToEndInLoopbackRsps,
juniAtmF4FlowSegmentInLoopbackCmds,
juniAtmF4FlowSegmentInLoopbackRsps,
juniAtmF4FlowEndToEndOutLoopbackCmds,
juniAtmF4FlowEndToEndOutLoopbackRsps,
juniAtmF4FlowSegmentOutLoopbackCmds,
juniAtmF4FlowSegmentOutLoopbackRsps }
STATUS current
DESCRIPTION
"A collection of objects providing management of ATM F4 flow OAM
circuits in a Juniper product."
::= { juniAtmGroups 29 } -- JUNOSe 7.1
juniAtmGroup9 OBJECT-GROUP
OBJECTS {
juniAtmNextIfIndex,
juniAtmIfRowStatus,
juniAtmIfLowerIfIndex,
juniAtmIfIlmiVpi,
juniAtmIfIlmiVci,
juniAtmIfIlmiVcd,
juniAtmIfIlmiPollFrequency,
juniAtmIfIlmiAdminState,
juniAtmIfUniVersion,
juniAtmIfOamCellRxAdminState,
juniAtmIfInCells,
juniAtmIfOutCells,
juniAtmIfVcCount,
juniAtmIfMapGroup,
juniAtmIfCacAdminState,
juniAtmIfCacUbrWeight,
juniAtmIfCacSubscriptionBandwidth,
juniAtmIfCacAvailableBandwidth,
juniAtmIfAssociatedVcClassId,
juniAtmPvcStatsInCells,
juniAtmPvcStatsInCellOctets,
juniAtmPvcStatsInPackets,
juniAtmPvcStatsInPacketOctets,
juniAtmPvcStatsOutCells,
juniAtmPvcStatsOutCellOctets,
juniAtmPvcStatsOutPackets,
juniAtmPvcStatsOutPacketOctets,
juniAtmPvcStatsInCellErrors,
juniAtmPvcStatsinPacketErrors,
juniAtmPvcStatsOutCellErrors,
juniAtmPvcStatsOutPacketErrors,
juniAtmPvcStatsInPacketDiscards,
juniAtmPvcStatsInPacketOctetDiscards,
juniAtmPvcStatsInPacketUnknownProtocol,
juniAtmIfCapabilityTrafficShaping,
juniAtmIfCapabilityOam,
juniAtmIfCapabilityDefaultVcPerVp,
juniAtmIfCapabilityNumVpiVciBits,
juniAtmIfCapabilityMaxVcd,
juniAtmIfCapabilityMaxVpi,
juniAtmIfCapabilityMaxVci,
juniAtmVpDescription,
juniAtmBulkCircuitsNameRowStatus,
juniAtmBulkCircuitsNameId,
juniAtmBulkCircuitsIdName,
juniAtmBulkCircuitsIdNextInstance,
juniAtmBulkCircuitsRowStatus,
juniAtmBulkCircuitsMinVpi,
juniAtmBulkCircuitsMaxVpi,
juniAtmBulkCircuitsMinVci,
juniAtmBulkCircuitsMaxVci,
juniAtmBulkCircuitsAdminState,
juniAtmProfileOverrideAssignIfCircuitRowStatus,
juniAtmProfileOverrideAssignIfCircuitProfileId,
juniAtmProfileOverrideAssignIfCircuitOperStatus }
STATUS current
DESCRIPTION
"A collection of objects providing management of ATM interfaces in a
Juniper product."
::= { juniAtmGroups 30 } -- JUNOSe 7.3
juniAtmSubIfGroup7 OBJECT-GROUP
OBJECTS {
juniAtmSubIfNextIfIndex,
juniAtmSubIfRowStatus,
juniAtmSubIfDistinguisher,
juniAtmSubIfLowerIfIndex,
juniAtmSubIfNbma,
juniAtmSubIfAddress,
juniAtmSubIfMtu,
juniAtmSubIfAdvisoryRxSpeed,
juniAtmSubIfAssociatedVcClassId,
juniAtmSubIfVccRowStatus,
juniAtmSubIfVccVcd,
juniAtmSubIfVccType,
juniAtmSubIfVccServiceCategory,
juniAtmSubIfVccPcr,
juniAtmSubIfVccScr,
juniAtmSubIfVccMbs,
juniAtmSubIfInverseArp,
juniAtmSubIfInverseArpRefresh,
juniAtmSubIfVccAssociatedVcClassId,
juniAtmCircuitOamAdminStatus,
juniAtmCircuitOamLoopbackOperStatus,
juniAtmCircuitVcOamOperStatus,
juniAtmCircuitOamLoopbackFrequency,
juniAtmCircuitInOamF5Cells,
juniAtmCircuitInOamCellsDropped,
juniAtmCircuitOutOamF5Cells,
juniAtmCircuitInOamF5EndToEndLoopbackCells,
juniAtmCircuitInOamF5SegmentLoopbackCells,
juniAtmCircuitInOamF5AisCells,
juniAtmCircuitInOamF5RdiCells,
juniAtmCircuitOutOamF5EndToEndLoopbackCells,
juniAtmCircuitOutOamF5SegmentLoopbackCells,
juniAtmCircuitOutOamF5RdiCells,
juniAtmCircuitInOamF5EndToEndLoopbackCmds,
juniAtmCircuitInOamF5EndToEndLoopbackRsps,
juniAtmCircuitInOamF5SegmentLoopbackCmds,
juniAtmCircuitInOamF5SegmentLoopbackRsps,
juniAtmCircuitOutOamF5EndToEndLoopbackCmds,
juniAtmCircuitOutOamF5EndToEndLoopbackRsps,
juniAtmCircuitOutOamF5SegmentLoopbackCmds,
juniAtmCircuitOutOamF5SegmentLoopbackRsps,
juniAtmCircuitOamUpCount,
juniAtmCircuitOamDownCount,
juniAtmCircuitOamRetryFrequency,
juniAtmCircuitOamAlarmDownCount,
juniAtmCircuitOamAlarmClearTimeout,
juniAtmSubIfDescriptionExport }
STATUS current
DESCRIPTION
"A collection of objects providing management of ATM subinterfaces in a
Juniper product."
::= { juniAtmGroups 31 } -- JUNOSe 7.3
juniAtmVcClassGroup OBJECT-GROUP
OBJECTS {
juniAtmVcClassName,
juniAtmVcClassNameRowStatus,
juniAtmVcClassNameId,
juniAtmVcClassIdName,
juniAtmVcClassVccType,
juniAtmVcClassVccServiceCategory,
juniAtmVcClassVccPcr,juniAtmVcClassVccScr,
juniAtmVcClassVccMbs,
juniAtmVcClassVccOamAdminStatus,
juniAtmVcClassVccOamLoopbackFrequency,
juniAtmVcClassVccOamUpCount,
juniAtmVcClassVccOamDownCount,
juniAtmVcClassVccOamRetryFrequency,
juniAtmVcClassVccOamAlarmDownCount,
juniAtmVcClassVccOamAlarmClearTimeout,
juniAtmVcClassVccInverseArp,
juniAtmVcClassVccInverseArpRefresh}
STATUS current
DESCRIPTION
"A collection of objects providing management of ATM VC class in a
Juniper product." -- JUNOSe7.3
::= { juniAtmGroups 32 }