S5-CHASSIS-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY,
Integer32, Counter32, Gauge32,
TimeTicks, IpAddress
FROM SNMPv2-SMI
DisplayString, TruthValue
FROM SNMPv2-TC
s5Chassis
FROM S5-ROOT-MIB
AttId, LocChan
FROM S5-TCS-MIB
Ipv6Address, Ipv6AddressPrefix
FROM IPV6-TC
InterfaceIndex
FROM IF-MIB;
s5ChasMib MODULE-IDENTITY
LAST-UPDATED "201504070000Z"
ORGANIZATION "Avaya"
CONTACT-INFO "Avaya"
DESCRIPTION
"5000 Chassis MIB
Copyright 1995-2012 Nortel Networks, Inc.
All rights reserved.
This Nortel Networks SNMP Management Information Base Specification
(Specification) embodies Nortel Networks' confidential and
proprietary intellectual property. Nortel Networks retains all
title and ownership in the Specification, including any
revisions.
This Specification is supplied 'AS IS', and Nortel Networks makes
no warranty, either express or implied, as to the use,
operation, condition, or performance of the Specification."
REVISION "201504070000Z" -- April 7, 2015
DESCRIPTION "Version 155: Changed s5ChasComDescr size."
REVISION "201311260000Z" -- November 26, 2013
DESCRIPTION "Version 154: Added s5ChasComUpTime object in s5ChasComTable."
REVISION "201310180000Z" -- October 18, 2013
DESCRIPTION "Version 153: Added s5ChasComIpMgmtShutdown."
REVISION "201310160000Z" -- October 16, 2013
DESCRIPTION "Version 152: Added s5ChasPluggables,
s5ChasGbicInfoTable."
REVISION "201310100000Z" -- October 10, 2013
DESCRIPTION "Version 151: Corrected MIB definitions."
REVISION "201309090000Z" -- September 9, 2013
DESCRIPTION "Version 150: Added s5ChasComIpMgmtLimit,
s5ChasComIpMgmtTimeout."
REVISION "201308270000Z" -- August 27, 2013
DESCRIPTION "Version 149: Added s5ChasBrdFanLeds."
REVISION "201212200000Z" -- December 20, 2012
DESCRIPTION "Version 148: Added s5ChasStoreDescription,
s5ChasStoreAge."
REVISION "201206010000Z" -- June 1, 2012
DESCRIPTION "Version 147: Added s5ChasComIpv6MgmtAddress,
s5ChasComIpv6MgmtNetMask."
REVISION "201202210000Z" -- Feb 21, 2012
DESCRIPTION "Version 146: Added s5ChasComIpMgmtAddress,
s5ChasComIpMgmtNetMask,
s5ChasComIpMgmtGateway."
REVISION "201110110000Z" -- Oct 11, 2011
DESCRIPTION "Version 145: Added s5ChasComIpv6Address, s5ChasComIpv6NetMask."
REVISION "201104220000Z" -- Apr 22, 2011
DESCRIPTION "Version 144: Added s5ChasNotify."
REVISION "201010180000Z" -- Oct 18, 2010
DESCRIPTION "Version 143: Added s5ChasStoreUsedSize."
REVISION "200805220000Z" -- May 22, 2008
DESCRIPTION "Version 142: Added s5ChasComRunningSoftwareVer."
REVISION "200802200000Z" -- Feb 20, 2008
DESCRIPTION "Version 141: Added objects for memory utilization in MegaBytes."
REVISION "200505110000Z" -- May 11, 2005
DESCRIPTION "Version 140: Fix support for USB flash dongles."
REVISION "200505050000Z" -- May 5, 2005
DESCRIPTION "Version 139: Fleshed out support for USB flash dongles."
REVISION "200410290000Z" -- October 29, 2004
DESCRIPTION "Version 138: Added baystack15 rpsu type."
REVISION "200407200000Z" -- July 20, 2004
DESCRIPTION "Version 137: Added version info."
::= { s5Chassis 10 }
-- Chassis Groups
s5ChasGen OBJECT IDENTIFIER ::= { s5Chassis 1 }
s5ChasGrp OBJECT IDENTIFIER ::= { s5Chassis 2 }
s5ChasCom OBJECT IDENTIFIER ::= { s5Chassis 3 }
s5ChasBrd OBJECT IDENTIFIER ::= { s5Chassis 4 }
s5ChasStore OBJECT IDENTIFIER ::= { s5Chassis 5 }
s5ChasSm OBJECT IDENTIFIER ::= { s5Chassis 6 }
s5ChasTmpSnr OBJECT IDENTIFIER ::= { s5Chassis 7 }
s5ChasUtil OBJECT IDENTIFIER ::= { s5Chassis 8 }
s5ChasPs OBJECT IDENTIFIER ::= { s5Chassis 9 }
s5ChasNotify OBJECT IDENTIFIER ::= { s5Chassis 11 }
s5ChasPluggables OBJECT IDENTIFIER ::= { s5Chassis 12 }
-- SECTION 2: MIB Objects
-- General Chassis Information
s5ChasType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The chassis type. This is 'what kind of
box' is being managed. The values are
defined under s5ChasTypeVal in the
Registration MIB."
::= { s5ChasGen 1 }
s5ChasDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of the chassis.
The value is a zero length string
if no information is available."
::= { s5ChasGen 2 }
s5ChasLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The physical location of the chassis
(e.g., 'fourth floor wiring closet in
building A'). The value is a zero
length string if no information
is available. Note: this object is
different from sysLocation in MIB-II.
However, an agent may use this value for
sysLocation if none is configured in the
the agent."
::= { s5ChasGen 3 }
s5ChasContact OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The textual identification of the
contact person for the chassis, together
with information on how to contact
this person. The value is a zero length
string if no information is available.
Note: this object is different from sysContact
in MIB-II. However, an agent may use this value
for sysContact if none is configured in the
agent."
::= { s5ChasGen 4 }
s5ChasVer OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of the chassis in the form
'major.minor.maintenance[letters]'. If the
version is unknown or not available then
the value should be a zero length string."
::= { s5ChasGen 5 }
s5ChasSerNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number of the chassis. If the
serial number is unknown or unavailable then
the value should be a zero length string."
::= { s5ChasGen 6 }
s5ChasGblPhysChngs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of physical changes (i.e.,
an addition or removal of a component or
sub-component) that have been detected in the
chassis since cold/warm start of the agent."
::= { s5ChasGen 7 }
s5ChasGblPhysLstChng OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the last
physical change (i.e., addition or
removal of a module or sub-module) was
detected in the chassis. If none have
been detected since cold/warm start of
the agent, then the value is zero."
::= { s5ChasGen 8 }
s5ChasGblAttChngs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of attachment changes
across all boards in the chassis that have
been detected since cold/warm start of
the agent."
::= { s5ChasGen 9 }
s5ChasGblAttLstChng OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the last
attachment change on any board in the chassis
was detected. If none have been detected
since cold/warm start of the agent, then the
value is zero."
::= { s5ChasGen 10 }
s5ChasGblConfChngs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of configuration changes
(other than attachment changes, or physical
additions or removals) across all boards in
the chassis that have been detected since
cold/warm start of the agent."
::= { s5ChasGen 11 }
s5ChasGblConfLstChng OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the last
configuration change (other than attachment
changes, or physical additions or removals)
on any board in the chassis was detected.
If none have been detected since cold/warm
start of the agent, then the value is zero."
::= { s5ChasGen 12 }
-- Chassis Group Table
s5ChasGrpTable OBJECT-TYPE
SYNTAX SEQUENCE OF S5ChasGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains information about
each group that can contain chassis
components."
::= { s5ChasGrp 1 }
s5ChasGrpEntry OBJECT-TYPE
SYNTAX S5ChasGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the group table.
Rows can not be created or deleted via
SNMP requests. The number of entries
is determined by the physical construction
of the chassis."
INDEX { s5ChasGrpIndx }
::= { s5ChasGrpTable 1 }
S5ChasGrpEntry ::= SEQUENCE {
s5ChasGrpIndx Integer32,
s5ChasGrpType OBJECT IDENTIFIER,
s5ChasGrpDescr DisplayString,
s5ChasGrpMaxEnts Integer32,
s5ChasGrpNumEnts Integer32,
s5ChasGrpPhysChngs Counter32,
s5ChasGrpPhysLstChng TimeTicks,
s5ChasGrpEncodeFactor Integer32
}
s5ChasGrpIndx OBJECT-TYPE
SYNTAX Integer32 (1..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the group."
::= { s5ChasGrpEntry 1 }
s5ChasGrpType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the group. The group type
determines the types of items that can
be plugged into the positions in the
group. The groups are defined under
s5ChasGrpTypeVal in the Registration MIB."
::= { s5ChasGrpEntry 2 }
s5ChasGrpDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of the group. If not
available, the value is a zero length
string."
::= { s5ChasGrpEntry 3 }
s5ChasGrpMaxEnts OBJECT-TYPE
SYNTAX Integer32 (-1..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of entries
in the group. If not available, a
value of -1 is returned."
::= { s5ChasGrpEntry 4 }
s5ChasGrpNumEnts OBJECT-TYPE
SYNTAX Integer32 (-1..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of entries
in the group. If not available,
a value of -1 is returned."
::= { s5ChasGrpEntry 5 }
s5ChasGrpPhysChngs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of physical changes (i.e.,
an addition or removal of a component or
sub-component) that have been detected in
the group since cold/warm start of the agent."
::= { s5ChasGrpEntry 6 }
s5ChasGrpPhysLstChng OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime that the last
physical change (i.e., addition or
removal of a module or sub-module) was
detected in the group. If none have been
detected since cold/warm start of the
agent, then the value is zero."
::= { s5ChasGrpEntry 7 }
s5ChasGrpEncodeFactor OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The multiplication factor used in encoding
the component index of a component in the group.
The component index for any group should be
determined in conjunction with this object for
that group. A value of 1 indicates 'no encoding'.
Stackable platforms:
The component index is encoded using the
following formula:
Component Index =
(Unit# * s5ChasGrpEncodeFactor) + Module#
Where: Unit# is obtained from s5ChasComIndx
for the Unit Group, and Module# is the
module number in a unit starting from 1
and increases in a left-to-right and
bottom-to-top fashion.
NonStackable platforms:
These NMMs like 5310, 5510 will always return a
value of 1 for this object. Encoding/decoding
should not be performed in this case."
::= { s5ChasGrpEntry 8 }
-- Component (and sub-component) Table
s5ChasComTable OBJECT-TYPE
SYNTAX SEQUENCE OF S5ChasComEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains information
about each chassis level component
and sub-component."
::= { s5ChasCom 1 }
s5ChasComEntry OBJECT-TYPE
SYNTAX S5ChasComEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the component/sub-component
table. Rows can not be created or
deleted via SNMP requests. Entries are
created and deleted when components or
sub-components are inserted or removed
from the chassis."
INDEX { s5ChasComGrpIndx,
s5ChasComIndx,
s5ChasComSubIndx }
::= { s5ChasComTable 1 }
S5ChasComEntry ::= SEQUENCE {
s5ChasComGrpIndx Integer32,
s5ChasComIndx Integer32,
s5ChasComSubIndx Integer32,
s5ChasComType OBJECT IDENTIFIER,
s5ChasComDescr DisplayString,
s5ChasComVer DisplayString,
s5ChasComSerNum DisplayString,
s5ChasComLstChng TimeTicks,
s5ChasComAdminState INTEGER,
s5ChasComOperState INTEGER,
s5ChasComMaxSubs Integer32,
s5ChasComNumSubs Integer32,
s5ChasComRelPos Integer32,
s5ChasComLocation DisplayString,
s5ChasComGroupMap Integer32,
s5ChasComBaseNumPorts Integer32,
s5ChasComTotalNumPorts Integer32,
s5ChasComIpAddress IpAddress,
s5ChasComRunningSoftwareVer DisplayString,
s5ChasComIpv6Address Ipv6Address,
s5ChasComIpv6NetMask Ipv6AddressPrefix,
s5ChasComIpMgmtAddress IpAddress,
s5ChasComIpMgmtNetMask IpAddress,
s5ChasComIpMgmtGateway IpAddress,
s5ChasComIpv6MgmtAddress Ipv6Address,
s5ChasComIpv6MgmtNetMask Ipv6AddressPrefix,
s5ChasComIpMgmtLimit Integer32,
s5ChasComIpMgmtTimeout Integer32,
s5ChasComIpMgmtShutdown TruthValue,
s5ChasComUpTime TimeTicks
}
s5ChasComGrpIndx OBJECT-TYPE
SYNTAX Integer32 (1..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the chassis level group which
contains this component."
::= { s5ChasComEntry 1 }
s5ChasComIndx OBJECT-TYPE
SYNTAX Integer32 (1..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the component in the group.
For example, for modules in the 'board'
group, this is the slot number."
::= { s5ChasComEntry 2 }
s5ChasComSubIndx OBJECT-TYPE
SYNTAX Integer32 (0..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If this table entry (i.e. table row)
describes a component, then the value is
zero. Otherwise, this table entry describes
a sub-component and this is the index of
the sub-component."
::= { s5ChasComEntry 3 }
s5ChasComType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of component/sub-component. The
values are defined under s5ChasComTypeVal
in the Registration MIB."
::= { s5ChasComEntry 4 }
s5ChasComDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of the component/sub-component.
If not available, the value is a zero length
string."
::= { s5ChasComEntry 5 }
s5ChasComVer OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version number of the component/sub-component.
If not available, the value is a zero length
string."
::= { s5ChasComEntry 6 }
s5ChasComSerNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number of the component/sub-component.
If not available, the value is a zero length
string."
::= { s5ChasComEntry 7 }
s5ChasComLstChng OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when it was
detected that the component/sub-component
was added to the chassis. If this has not
occurred since the cold/warm start of the
agent, then the value is zero."
::= { s5ChasComEntry 8 }
s5ChasComAdminState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
notAvail(2),
disable(3),
enable(4),
reset(5),
test(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The desired state of the component/sub-component.
The values that are read-only are:
other(1)......currently in some other state
notAvail(2)...actual value is not available
The possible values that can be read and
written are:
disable(3)...disable operation
enable(4)....enable operation
reset(5).....reset component
test(6)......start self test of component, with
the result to be normal(5),
warning(8), nonFatalErr(9),
or fatalErr(10) in object
s5ChasComOperState
The allowable (and meaningful) values
are determined by the component type."
::= { s5ChasComEntry 9 }
s5ChasComOperState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
notAvail(2),
removed(3),
disabled(4),
normal(5),
resetInProg(6),
testing(7),
warning(8),
nonFatalErr(9),
fatalErr(10),
notConfig(11),
obsoleted(12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational state of the
component. The possible values are:
other(1).........some other state
notAvail(2)......state not available
removed(3).......component removed
disabled(4)......operation disabled
normal(5)........normal operation
resetInProg(6)...reset in progress
testing(7).......doing a self test
warning(8).......operating at warning level
nonFatalErr(9)...operating at error level
fatalErr(10).....error stopped operation
notConfig(11)....module needs to be configured
obsoleted(12)...module is obsoleted but in the chassis
The allowable (and meaningful) values
are determined by the component type."
::= { s5ChasComEntry 10 }
s5ChasComMaxSubs OBJECT-TYPE
SYNTAX Integer32 (-1..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The potential number of sub-components
that can be attached to the component.
A value of zero means none. A value of -1
indicates that no component information is
available. The actual number of
installed sub-components is found in
s5ChasComNumSubs.
If this entry is a sub-component, then
this object has a value of zero."
::= { s5ChasComEntry 11 }
s5ChasComNumSubs OBJECT-TYPE
SYNTAX Integer32 (-1..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual number of sub-components that
are attached to the component. A value of
zero means none. A value of -1 indicates
that no component information is available.
The potential number of sub-components
that can be installed is found in
s5ChasComMaxSubs.
If this entry is a sub-component, then
this object has the value of zero."
::= { s5ChasComEntry 12 }
s5ChasComRelPos OBJECT-TYPE
SYNTAX Integer32 (0..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the position of
each component in the unit group relative
to each other. Components in the unit group
are numbered in the ascending order with the
uppermost component being numbered one. The
value of this object should never be greater
than the value of s5ChasGrpMaxEnts. If not
available, a value of zero will be returned.
Note: This object is only implemented in
agents that support 'virtual' chassis."
::= { s5ChasComEntry 13 }
s5ChasComLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object provides geographic location
information of a component in a system
modeled as a chassis, but possibly physically
implemented with geographically separate devices
connected together to exchange managment information.
Chassis' modeled in this manner are sometimes refered
to as 'virtual chassis'. An example value is:
'4th flr wiring closet in blg A'.
Notes: 1.) This object is applicable only to
components that can be found in either
the Board or Unit groups. If the
information is unavailable (i.e., not
modeling a virtual chassis or component
is not in Board or Unit group), the value
is a zero length string.
2.) If this object is applicable and is not
assigned a value via a SNMP SET PDU when
the row is created, the value will default
to the value of the object s5ChasComSerNum."
::= { s5ChasComEntry 14 }
s5ChasComGroupMap OBJECT-TYPE
SYNTAX Integer32 (0..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the group mapping of
each component in the chassis. For the
components in the unit group, the value of this
object should be the backplane number to which the
unit is connected. The value of this object should
never be greater than the value of s5ChasGrpMaxEnts.
If not available, a value of zero should be returned."
::= { s5ChasComEntry 15 }
s5ChasComBaseNumPorts OBJECT-TYPE
SYNTAX Integer32 (0..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of ports (of any type)
contained in a component, not including any sub-components
contained within the component."
::= { s5ChasComEntry 16 }
s5ChasComTotalNumPorts OBJECT-TYPE
SYNTAX Integer32 (0..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the total number of ports (of
any type) contained in a component, including any ports
contained in sub-components contained within the component."
::= { s5ChasComEntry 17 }
s5ChasComIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of a component. For components that do not
have an IP address/stack, this value should always be 0.0.0.0.
Note that for a stackable system in stack mode, this will be
the standalone IP address for individual units in the stack."
::= { s5ChasComEntry 18 }
s5ChasComRunningSoftwareVer OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version number of the software image running on this
component/sub-component.
If not available, the value is a zero length
string."
::= { s5ChasComEntry 19 }
s5ChasComIpv6Address OBJECT-TYPE
SYNTAX Ipv6Address
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv6 address of a component. For components that do not
have an IPv6 address/stack, this value should always be 0::0.
Note that for a stackable system in stack mode, this will be
the standalone IPv6 address for individual units in the stack."
::= { s5ChasComEntry 20 }
s5ChasComIpv6NetMask OBJECT-TYPE
SYNTAX Ipv6AddressPrefix
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv6 netmask of a component. For components that do not
have an IPv6 address/stack, this value should always be 0::0.
Note that for a stackable system in stack mode, this will be
the standalone IPv6 netmask for individual units in the stack."
::= { s5ChasComEntry 21 }
s5ChasComIpMgmtAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address associated with the physical dedicated
management port (out of band management port) of a component. For
components that do not have an IP address/stack associated with the
dedicated management port, this value should always be 0.0.0.0.
Note that for a stackable system in stack mode, this IP address
always applies to individual units in the stack."
::= { s5ChasComEntry 22 }
s5ChasComIpMgmtNetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP netmask associated with the physical dedicated
management port (out of band management port) of a component. For
components that do not have an IP address/stack associated with the
dedicated management port, this value should always be 0.0.0.0.
Note that for a stackable system in stack mode, this netmask
always applies to individual units in the stack."
::= { s5ChasComEntry 23 }
s5ChasComIpMgmtGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the default gateway associated with the
physical dedicated management port (out of band management port)
of a component. For components that do not have an IP address/stack
associated with the dedicated management port, this value should
always be 0.0.0.0.
Note that for a stackable system in stack mode, this IP address
always applies to individual units in the stack."
::= { s5ChasComEntry 24 }
s5ChasComIpv6MgmtAddress OBJECT-TYPE
SYNTAX Ipv6Address
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv6 address associated with the physical dedicated
management port (out of band management port) of a component.
Note that for a stackable system in stack mode, this IP address
always applies to individual units in the stack."
::= { s5ChasComEntry 25 }
s5ChasComIpv6MgmtNetMask OBJECT-TYPE
SYNTAX Ipv6AddressPrefix
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv6 netmask associated with the physical dedicated
management port (out of band management port) of a component.
Note that for a stackable system in stack mode, this netmask
always applies to individual units in the stack."
::= { s5ChasComEntry 26 }
s5ChasComIpMgmtLimit OBJECT-TYPE
SYNTAX Integer32 (50..10000)
UNITS "packets per second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the in-bound packet threshold rate
for the management port (out of band management port)."
DEFVAL { 7000 }
::= { s5ChasComEntry 27 }
s5ChasComIpMgmtTimeout OBJECT-TYPE
SYNTAX Integer32 (0..180)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the port shutdown period
for the management port (out of band management port)."
DEFVAL { 180 }
::= { s5ChasComEntry 28 }
s5ChasComIpMgmtShutdown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to control whether the out of band management
port is up or down (false for port up and true for port down)."
DEFVAL { false }
::= { s5ChasComEntry 29 }
s5ChasComUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time (in hundredths of a second)
since the unit was initialized."
::= { s5ChasComEntry 30 }
-- Board Table
s5ChasBrdTable OBJECT-TYPE
SYNTAX SEQUENCE OF S5ChasBrdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about each
board that can be inserted into a slot.
These include boards such as Repeater Modules
and Network Management Modules."
::= { s5ChasBrd 1 }
s5ChasBrdEntry OBJECT-TYPE
SYNTAX S5ChasBrdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the board table. Entries can not
be created or deleted via SNMP. Entries are
created and deleted when boards are inserted
or removed from slots in the chassis."
INDEX { s5ChasBrdIndx }
::= { s5ChasBrdTable 1 }
S5ChasBrdEntry ::= SEQUENCE {
s5ChasBrdIndx Integer32,
s5ChasBrdLeds OCTET STRING,
s5ChasBrdNumAtt Integer32,
s5ChasBrdAttChngs Counter32,
s5ChasBrdAttLstChng TimeTicks,
s5ChasBrdStatusDsply DisplayString,
s5ChasBrdDateCode DisplayString,
s5ChasBrdCfgSrc INTEGER,
s5ChasBrdCfgChngs Counter32,
s5ChasBrdFanLeds OCTET STRING
}
s5ChasBrdIndx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the board. This corresponds to
the index of the slot containing the board."
::= { s5ChasBrdEntry 1 }
s5ChasBrdLeds OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit array that contains the value of the
front panel LEDs and the annunciator. This is
a packed bit string; each LED is encoded into
4 bits (a nibble). The first nibble is stored
in the high order bits of the first octet. The
second nibble is stored in the low order bits
the first octet, etc. However, the current
mapping is that the first three nibbles are
reserved, the fourth nibble has the value of
the 'annunciator', and the 'normal' LEDs start
with the fifth nibble. If the LED values are not
available, a zero length string is returned. The
following shows the meaning of each bit (bit 0 is
the least significant bit) when it has a value
of one:
bit meaning
--- -------
0 green light
1 yellow light
2 blinking
3 reserved"
::= { s5ChasBrdEntry 2 }
s5ChasBrdNumAtt OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of backplane network
attachment points on the board.
This may vary based on the mode of the
board for FDDI."
::= { s5ChasBrdEntry 3 }
s5ChasBrdAttChngs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of attachment changes
for the board that have been detected since
cold/warm start of the agent or since
the board was inserted."
::= { s5ChasBrdEntry 4 }
s5ChasBrdAttLstChng OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the last
attachment change on the board
has detected. If none have been detected
since cold/warm start of the agent, then
the value is zero."
::= { s5ChasBrdEntry 5 }
s5ChasBrdStatusDsply OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..48))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current ASCII character display of
the board. The length returned should
match the length of the display.
Boards with multiple displays should
return the values concatenated together.
Boards with no display hardware should
return a zero length string."
::= { s5ChasBrdEntry 6 }
s5ChasBrdDateCode OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date of manufacture of the board
in ASCII in the format: YYYYmmdd. For
example, the value for April 13, 1993
is 19930413. If not available, the
value is a zero-length string."
::= { s5ChasBrdEntry 7 }
s5ChasBrdCfgSrc OBJECT-TYPE
SYNTAX INTEGER {
other(1),
dfltJmpr(2),
prmMem(3),
brdCfg(4),
sm(5),
smDfltJmpr(6),
smPrmMem(7),
smBrdCfg(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The source of the configuration
at the last board reset. The values
are:
other(1)........unknown or some other value
dfltJmpr(2).....default jumpers
prmMem(3).......permanent memory on board
brdCfg(4).......saved configuration on board
sm(5)...........supervisor
smDfltJmpr(6)...SM and default jumpers
smPrmMem(7).....SM and permanent memory on board
smBrdCfg(8).....SM and saved configuration on board"
::= { s5ChasBrdEntry 8 }
s5ChasBrdCfgChngs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of configuration
changes for the board that have been
detected since cold/warm start of the
agent or since the board was inserted."
::= { s5ChasBrdEntry 9 }
s5ChasBrdFanLeds OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit array that contains the value of the
front panel LEDs of the fan trays. This is
a packed bit string; each LED is encoded into
4 bits (a nibble). The first nibble is stored
in the high order bits of the first octet. The
second nibble is stored in the low order bits
of the first octet etc. The current mapping is
that the first four nibbles are reserved,
the fifth nibble has the value of the
'annunciator', and the 'normal' LEDs start with
the sixth nibble. If the LED values are not
available, a zero length string is returned. The
following shows the meaning of each bit (bit 0 is
the least significant bit) when it has a value
of one:
bit meaning
--- -------
0 red light
1 blue light
2 purple light
3 blinking
4 reserved"
::= { s5ChasBrdEntry 10 }
-- Attachment Point Table
s5ChasAttTable OBJECT-TYPE
SYNTAX SEQUENCE OF S5ChasAttEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about each
backplane attachment point on a board.
The number of entries for a board is the
value of s5ChasBrdNumAtt."
::= { s5ChasBrd 2 }
s5ChasAttEntry OBJECT-TYPE
SYNTAX S5ChasAttEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the attachment point table.
Entries can not be created or deleted
via SNMP. Entries are created and deleted
when boards are inserted or removed from
slots in the chassis, or the number of
attachment points is changed."
INDEX { s5ChasAttBrdIndx,
s5ChasAttIndx }
::= { s5ChasAttTable 1 }
S5ChasAttEntry ::= SEQUENCE {
s5ChasAttBrdIndx Integer32,
s5ChasAttIndx Integer32,
s5ChasAttDfltAtt AttId,
s5ChasAttCurAtt AttId,
s5ChasAttChngs Counter32,
s5ChasAttLstChng TimeTicks,
s5ChasAttClusterConnCapability OCTET STRING
}
s5ChasAttBrdIndx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the board. This corresponds to
the index of the slot containing the board."
::= { s5ChasAttEntry 1 }
s5ChasAttIndx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the attachment point on
the board."
::= { s5ChasAttEntry 2 }
s5ChasAttDfltAtt OBJECT-TYPE
SYNTAX AttId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The default setting for the attachment
point. An attachment point may be attached
to a local channel, not attached to any
backplane network, or attached to a media
specific backplane network. (The valid choices
depend on each specific attachment point.)
NOTE: This value will always be valid
and may change when the backplane divider
switch setting is changed."
::= { s5ChasAttEntry 3 }
s5ChasAttCurAtt OBJECT-TYPE
SYNTAX AttId
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current setting for the attachment
point. The slot position of the board,
the setting of the backplane divider switch(es),
and the mode setting affect which backplane
networks are valid values. Also, some boards
may put limitations on which backplane
network(s) or local channel(s) may be used."
::= { s5ChasAttEntry 4 }
s5ChasAttChngs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of attachment changes
for the attachment point that have been
detected since cold/warm start of the agent."
::= { s5ChasAttEntry 5 }
s5ChasAttLstChng OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the last
attachment change for the attachment
point was detected. If none have been
detected since cold/warm start of the
agent, then the value is zero."
::= { s5ChasAttEntry 6 }
s5ChasAttClusterConnCapability OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit array that contains the bit map
representing all available backplane
segment and local segment connections for
the cluster. One bit is also reserved to
indicate if the cluster has an isolate
capability.
The first 31 bits of the array represent
the backplane numbers, starting from the
lower order bit. Bit 32 indicates whether
the Cluster has a null connection capability.
The bits in the fifth and sixth octets,
starting with bits in the lower order octet,
represent local segments that the cluster
can connect to.
A bit with a value of 1 means that the
cluster is capable of connecting to the
corresponding backplane segment, local segment
or null segment."
::= { s5ChasAttEntry 7 }
-- Local Channel Table
s5ChasLocChanTable OBJECT-TYPE
SYNTAX SEQUENCE OF S5ChasLocChanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about each
'dual mode' local channel on a board."
::= { s5ChasBrd 3 }
s5ChasLocChanEntry OBJECT-TYPE
SYNTAX S5ChasLocChanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the local channel table.
Entries can not be created or deleted
via SNMP. Entries are added or removed
by adding or removing a board that has
a 'dual mode' local channel from a slot
in the chassis."
INDEX { s5ChasLocChanBrdIndx,
s5ChasLocChanIndx }
::= { s5ChasLocChanTable 1 }
S5ChasLocChanEntry ::= SEQUENCE {
s5ChasLocChanBrdIndx Integer32,
s5ChasLocChanIndx LocChan,
s5ChasLocChanBkplMode INTEGER
}
s5ChasLocChanBrdIndx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the board. This corresponds to
the index of the slot containing the board."
::= { s5ChasLocChanEntry 1 }
s5ChasLocChanIndx OBJECT-TYPE
SYNTAX LocChan
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the local channel."
::= { s5ChasLocChanEntry 2 }
s5ChasLocChanBkplMode OBJECT-TYPE
SYNTAX INTEGER {
other(1),
connected(2),
notConnected(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the attachment/isolation
mode of a local channel to a backplane
channel. The values that are read/write are:
connected(2)......connect local chan N to bkpl N
notConnected(3)...disconnect local chan N from bkpl
The possible values that can be read are:
other(1)..........unknown
connected(2)......local chan N connected to bkpl N
notConnected(3)...local chan N isolated from bkpl N"
::= { s5ChasLocChanEntry 3 }
-- Storage Area Table
s5ChasStoreTable OBJECT-TYPE
SYNTAX SEQUENCE OF S5ChasStoreEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table listing the storage areas
on each component/sub-component in
the chassis. The number is determined
by the components in the chassis
which have manageable storage areas.
Examples of storage areas include
RAM(main memory), FLASH, ROM,
EEPROM, etc. This does not include
disk drives."
::= { s5ChasStore 1 }
s5ChasStoreEntry OBJECT-TYPE
SYNTAX S5ChasStoreEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the table of storage areas.
The entries can not be created or
deleted via SNMP requests. Only those
components/sub-components that have
storage areas that are installed are
present. Storage areas that are on
components have a sub-component
index value of zero. Storage areas that
are on sub-components have a non-zero
sub-component index value."
INDEX { s5ChasStoreGrpIndx,
s5ChasStoreComIndx,
s5ChasStoreSubIndx,
s5ChasStoreIndx }
::= { s5ChasStoreTable 1 }
S5ChasStoreEntry ::= SEQUENCE {
s5ChasStoreGrpIndx Integer32,
s5ChasStoreComIndx Integer32,
s5ChasStoreSubIndx Integer32,
s5ChasStoreIndx Integer32,
s5ChasStoreType OBJECT IDENTIFIER,
s5ChasStoreCurSize Integer32,
s5ChasStoreCntntVer DisplayString,
s5ChasStoreFilename DisplayString,
s5ChasStoreUsedSize Integer32,
s5ChasStoreDescription DisplayString,
s5ChasStoreAge Integer32
}
s5ChasStoreGrpIndx OBJECT-TYPE
SYNTAX Integer32 (1..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the chassis level group
which contains the component or
sub-component containing the storage
area."
::= { s5ChasStoreEntry 1 }
s5ChasStoreComIndx OBJECT-TYPE
SYNTAX Integer32 (1..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the component or
the component which contains the
sub-component containing the
storage area."
::= { s5ChasStoreEntry 2 }
s5ChasStoreSubIndx OBJECT-TYPE
SYNTAX Integer32 (0..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the storage area is on a component,
then the value zero. Otherwise, the
storage area is on a sub-component and
this is the index of the sub-component."
::= { s5ChasStoreEntry 3 }
s5ChasStoreIndx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the storage area on the
component or sub-component."
::= { s5ChasStoreEntry 4 }
s5ChasStoreType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The storage area type on the containing
component/sub-component. The values
are defined under the .0 branch of the
value of s5ChasComType for the
component/sub-component containing the
storage area in the Registration MIB."
::= { s5ChasStoreEntry 5 }
s5ChasStoreCurSize OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current size of the storage
area in bytes. A value of zero
means the storage area is not installed
or not usable. A value of -1 indicates
that the size is unknown (or unavailable)."
::= { s5ChasStoreEntry 6 }
s5ChasStoreCntntVer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of the contents (i.e., the
code or data) of the storage area in the
form 'major.minor.maintenance[letters]'.
If not known or not available, then the value
is a zero length string. If multiple
contents are stored in this container, the
the value will contain multiple sub-versions,
each separated by a semicolon (;)."
::= { s5ChasStoreEntry 7 }
s5ChasStoreFilename OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of the image file to be downloaded or
uploaded when the s5AgInfoFileAction object
is set to upload or download an image. When the
object is not used, the value is a zero-length
string."
::= { s5ChasStoreEntry 8 }
s5ChasStoreUsedSize OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current size of the storage area that is currently in use,
measured in bytes. A value of zero means the storage area is
not in use. A value of -1 means the size is unknown
(or unavailable)."
::= { s5ChasStoreEntry 9 }
s5ChasStoreDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A string describing the storage area. When the
object is not used, the value is a zero-length
string."
::= { s5ChasStoreEntry 10 }
s5ChasStoreAge OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A counter of the number of writes performed on this storage
area which for areas residing in flash memory is an
indication of the flash memory age. This number is the maximum
number of writes for any of the access units (e.g. sector) from
the storage area. A value of zero means the storage area is
not in use. A value of -1 means the age is unknown
(or unavailable)."
::= { s5ChasStoreEntry 11 }
-- Supervisor Information
s5ChasSmLeds OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit array that contains the value of the
supervisor LEDs. (The format of these are the
same as the format for object s5ChasBrdLeds.)
If not available, a zero length string is
returned."
::= { s5ChasSm 1 }
s5ChasSmDateCode OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date of manufacture of the SM module
in ASCII in the format: YYYYmmdd. For
example, the value for April 13, 1993
is 19930413. If not available, a zero
length string is returned"
::= { s5ChasSm 2 }
-- Temperature Sensor Table
s5ChasTmpSnrTable OBJECT-TYPE
SYNTAX SEQUENCE OF S5ChasTmpSnrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains temperature
sensor values."
::= { s5ChasTmpSnr 1 }
s5ChasTmpSnrEntry OBJECT-TYPE
SYNTAX S5ChasTmpSnrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the s5ChasTmpSnrTable. Rows
in this table will exist for each existing
row in the s5ChasComTable which represents
a temperature sensor. The values of the
indices of the row in this table will be
equal to those of the corresponding row in
the s5ChasComTable."
INDEX { s5ChasTmpSnrGrpIndx,
s5ChasTmpSnrIndx,
s5ChasTmpSnrSubIndx }
::= { s5ChasTmpSnrTable 1 }
S5ChasTmpSnrEntry ::= SEQUENCE {
s5ChasTmpSnrGrpIndx Integer32,
s5ChasTmpSnrIndx Integer32,
s5ChasTmpSnrSubIndx Integer32,
s5ChasTmpSnrValue Gauge32,
s5ChasTmpSnrTmpValue Integer32
}
s5ChasTmpSnrGrpIndx OBJECT-TYPE
SYNTAX Integer32 (1..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the chassis level group which
contains this component, corresponds to
s5ChasComGrpIndx."
::= { s5ChasTmpSnrEntry 1 }
s5ChasTmpSnrIndx OBJECT-TYPE
SYNTAX Integer32 (1..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the component in the group.
Corresponds to s5ChasComIndx."
::= { s5ChasTmpSnrEntry 2 }
s5ChasTmpSnrSubIndx OBJECT-TYPE
SYNTAX Integer32 (0..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sub-component index. Corresponds to
s5ChasComSubIndx."
::= { s5ChasTmpSnrEntry 3 }
s5ChasTmpSnrValue OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The current temperature value of the temperature
sensor. This is measured in units of a half degree
centigrade, e.g. a value of 121 indicates a temperature
of 60.5 degrees C.
This object is deprecated because it cannot represent
temperature values below 0, as Gauge32 is an unsigned type."
::= { s5ChasTmpSnrEntry 4 }
s5ChasTmpSnrTmpValue OBJECT-TYPE
SYNTAX Integer32 (-32768..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current temperature value of the temperature
sensor. This is measured in units of a half degree
centigrade, e.g. a value of 121 indicates a temperature
of 60.5 degrees C."
::= { s5ChasTmpSnrEntry 5 }
-- Chassis Utilization Table, includes CPU and Memory Utilization information
s5ChasUtilTable OBJECT-TYPE
SYNTAX SEQUENCE OF S5ChasUtilEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains CPU and memory utilization
information."
::= { s5ChasUtil 1 }
s5ChasUtilEntry OBJECT-TYPE
SYNTAX S5ChasUtilEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the s5ChasUtilTable. Rows
in this table will exist for each existing
row in the s5ChasComTable which represents
any chassis component for which CPU and/or
memory utilization values are available.
The values of the indices of a row in this
table will be equal to those of the
corresponding row in the s5ChasComTable."
INDEX { s5ChasUtilGrpIndx,
s5ChasUtilIndx,
s5ChasUtilSubIndx }
::= { s5ChasUtilTable 1 }
S5ChasUtilEntry ::= SEQUENCE {
s5ChasUtilGrpIndx Integer32,
s5ChasUtilIndx Integer32,
s5ChasUtilSubIndx Integer32,
s5ChasUtilTotalCPUUsage Gauge32,
s5ChasUtilCPUUsageLast1Minute Gauge32,
s5ChasUtilCPUUsageLast10Minutes Gauge32,
s5ChasUtilCPUUsageLast1Hour Gauge32,
s5ChasUtilCPUUsageLast24Hours Gauge32,
s5ChasUtilMemoryAvailable Gauge32,
s5ChasUtilMemoryMinAvailable Gauge32,
s5ChasUtilCPUUsageLast10Seconds Gauge32,
s5ChasUtilMemoryTotalMB Gauge32,
s5ChasUtilMemoryAvailableMB Gauge32
}
s5ChasUtilGrpIndx OBJECT-TYPE
SYNTAX Integer32 (1..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the chassis level group which
contains this component, corresponds to
s5ChasComGrpIndx."
::= { s5ChasUtilEntry 1 }
s5ChasUtilIndx OBJECT-TYPE
SYNTAX Integer32 (1..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the component in the group.
Corresponds to s5ChasComIndx."
::= { s5ChasUtilEntry 2 }
s5ChasUtilSubIndx OBJECT-TYPE
SYNTAX Integer32 (0..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sub-component index. Corresponds to
s5ChasComSubIndx."
::= { s5ChasUtilEntry 3 }
s5ChasUtilTotalCPUUsage OBJECT-TYPE
SYNTAX Gauge32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the percentage of time the CPU has been
busy since system initialization."
::= {s5ChasUtilEntry 4}
s5ChasUtilCPUUsageLast1Minute OBJECT-TYPE
SYNTAX Gauge32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the percentage of time the CPU has been
busy over the last 1 minute."
::= {s5ChasUtilEntry 5}
s5ChasUtilCPUUsageLast10Minutes OBJECT-TYPE
SYNTAX Gauge32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the percentage of time the CPU has been
busy over the last 10 minutes."
::= {s5ChasUtilEntry 6}
s5ChasUtilCPUUsageLast1Hour OBJECT-TYPE
SYNTAX Gauge32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the percentage of time the CPU has been
busy over the last 1 hour."
::= {s5ChasUtilEntry 7}
s5ChasUtilCPUUsageLast24Hours OBJECT-TYPE
SYNTAX Gauge32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the percentage of time the CPU has been
busy over the last 24 hours."
::= {s5ChasUtilEntry 8}
s5ChasUtilMemoryAvailable OBJECT-TYPE
SYNTAX Gauge32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the percentage of dynamic memory that
is currently free. This is measured as a percentage of
the memory the was available immediately after system
initialization."
::= {s5ChasUtilEntry 9}
s5ChasUtilMemoryMinAvailable OBJECT-TYPE
SYNTAX Gauge32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the lowest percentage of dynamic
memory that has been free since system initialization.
This is a 'low-water mark' for memory utilization, and is
essentially the lowest value of s5ChasUtilMemoryUsage
since system initialization."
::= {s5ChasUtilEntry 10}
s5ChasUtilCPUUsageLast10Seconds OBJECT-TYPE
SYNTAX Gauge32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the percentage of time the CPU has been
busy over the last 10 seconds."
::= {s5ChasUtilEntry 11}
s5ChasUtilMemoryTotalMB OBJECT-TYPE
SYNTAX Gauge32 (0..1024)
UNITS "MegaBytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the total RAM of unit."
::= { s5ChasUtilEntry 12 }
s5ChasUtilMemoryAvailableMB OBJECT-TYPE
SYNTAX Gauge32 (0..1024)
UNITS "MegaBytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the available RAM of unit."
::= { s5ChasUtilEntry 13 }
-- Chassis Power Supply Table
s5ChasPsRpsuTable OBJECT-TYPE
SYNTAX SEQUENCE OF S5ChasPsRpsuEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains extended information on
RPSU power supply components."
::= { s5ChasPs 1 }
s5ChasPsRpsuEntry OBJECT-TYPE
SYNTAX S5ChasPsRpsuEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the s5ChasPsRpsuTable. Rows
in this table will exist for each existing
row in the s5ChasComTable which represents
any RPSU power supply. The values of the
indices of a row in this table will be equal
to those of the corresponding row in the
s5ChasComTable."
INDEX { s5ChasPsRpsuGrpIndx,
s5ChasPsRpsuIndx,
s5ChasPsRpsuSubIndx }
::= { s5ChasPsRpsuTable 1 }
S5ChasPsRpsuEntry ::= SEQUENCE {
s5ChasPsRpsuGrpIndx Integer32,
s5ChasPsRpsuIndx Integer32,
s5ChasPsRpsuSubIndx Integer32,
s5ChasPsRpsuType INTEGER,
s5ChasPsRpsuSourceConfig INTEGER
}
s5ChasPsRpsuGrpIndx OBJECT-TYPE
SYNTAX Integer32 (1..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the chassis level group which
contains this component, corresponds to
s5ChasComGrpIndx."
::= { s5ChasPsRpsuEntry 1 }
s5ChasPsRpsuIndx OBJECT-TYPE
SYNTAX Integer32 (1..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the component in the group.
Corresponds to s5ChasComIndx."
::= { s5ChasPsRpsuEntry 2 }
s5ChasPsRpsuSubIndx OBJECT-TYPE
SYNTAX Integer32 (0..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sub-component index. Corresponds to
s5ChasComSubIndx."
::= { s5ChasPsRpsuEntry 3 }
s5ChasPsRpsuType OBJECT-TYPE
SYNTAX INTEGER {
bayStack10(1),
nes(2),
bayStack15(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object returns the specific type of RPSU.
It can be set to indicate to the system the type
of installed RPSU in cases where the RPSU type
cannot be automatically detected."
::= {s5ChasPsRpsuEntry 4}
s5ChasPsRpsuSourceConfig OBJECT-TYPE
SYNTAX INTEGER {
ups(1),
rpsu(2),
powerSharing(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to specify how a particular
RPSU should be used by the system, as follows:
ups(1)
Indicates that the RPSU should be used only as
an uninterruptible power source for devices
attached to powered ethernet ports.
rpsu(2)
Indicates that the RPSU should be used only as
a source of backup power for the device itself.
powerSharing(3)
Indicates that the RPSU should be used both as
a source of backup power for the device, and as
a UPS for devices attached to powered ethernet
ports."
::= {s5ChasPsRpsuEntry 5}
-- Notification auxiliary objects
s5ChasNotifyFanDirection OBJECT-TYPE
SYNTAX INTEGER {
left(1),
right(2)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object is used in the s5CtrFanDirectionError notification to
indicate fan direction."
::= { s5ChasNotify 1 }
-- GBIC Information Table
s5ChasGbicInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF S5ChasGbicInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains information about
pluggable ports."
::= { s5ChasPluggables 1}
s5ChasGbicInfoEntry OBJECT-TYPE
SYNTAX S5ChasGbicInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the s5ChasGbicInfoTable."
INDEX { s5ChasGbicInfoIfIndex }
::= { s5ChasGbicInfoTable 1 }
S5ChasGbicInfoEntry ::= SEQUENCE {
s5ChasGbicInfoIfIndex InterfaceIndex,
s5ChasGbicInfoGbicType DisplayString,
s5ChasGbicInfoWavelength Integer32,
s5ChasGbicInfoVendorName DisplayString,
s5ChasGbicInfoVendorOui OCTET STRING,
s5ChasGbicInfoVendorPartNo DisplayString,
s5ChasGbicInfoVendorRevision DisplayString,
s5ChasGbicInfoVendorSerial DisplayString,
s5ChasGbicInfoHwOptions BITS,
s5ChasGbicInfoDateCode DisplayString,
s5ChasGbicInfoCleiCode DisplayString,
s5ChasGbicInfoProductCode DisplayString
}
s5ChasGbicInfoIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each interface."
::= { s5ChasGbicInfoEntry 1 }
s5ChasGbicInfoGbicType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of pluggable part."
::= { s5ChasGbicInfoEntry 2 }
s5ChasGbicInfoWavelength OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The wavelength value measured in nanometers for the pluggable part."
::= { s5ChasGbicInfoEntry 3 }
s5ChasGbicInfoVendorName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the vendor of the pluggable part."
::= { s5ChasGbicInfoEntry 4 }
s5ChasGbicInfoVendorOui OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (3))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Organizationally Unique Identifier (OUI) of the pluggable part."
::= { s5ChasGbicInfoEntry 5 }
s5ChasGbicInfoVendorPartNo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor part number of the pluggable part."
::= { s5ChasGbicInfoEntry 6 }
s5ChasGbicInfoVendorRevision OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor revision of the pluggable part."
::= { s5ChasGbicInfoEntry 7 }
s5ChasGbicInfoVendorSerial OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor serial number for the pluggable part."
::= { s5ChasGbicInfoEntry 8 }
s5ChasGbicInfoHwOptions OBJECT-TYPE
SYNTAX BITS {
rxLoss(0),
txFault(1),
txDisable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The hardware options supported by the pluggable part."
::= { s5ChasGbicInfoEntry 9 }
s5ChasGbicInfoDateCode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The manufacturing date of the pluggable part."
::= { s5ChasGbicInfoEntry 10 }
s5ChasGbicInfoCleiCode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Common Language Equipment Identification Code of the pluggable part."
::= { s5ChasGbicInfoEntry 11 }
s5ChasGbicInfoProductCode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The product code of the pluggable part."
::= { s5ChasGbicInfoEntry 12 }