mibs/MIBS/radwin/RADWIN-MIB-WINLINK1000

4272 lines
128 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
--
-- RADWIN Management Information Base (MIB)
-- Generated 01/05/16 14:23:32 Version: 10.2.40_b9653
--
RADWIN-MIB-WINLINK1000 DEFINITIONS ::= BEGIN
IMPORTS
enterprises, IpAddress, Counter, Gauge, TimeTicks
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
DisplayString, ifIndex
FROM RFC1213-MIB
TRAP-TYPE
FROM RFC-1215;
radwin OBJECT IDENTIFIER ::= { enterprises 4458 }
winlink1000 OBJECT IDENTIFIER ::= { radwin 1000 }
-- ###########################################################
-- ODU
-- ###########################################################
winlink1000Odu OBJECT IDENTIFIER ::= { winlink1000 1 }
-- ###########################################################
-- ODU Admin
-- ###########################################################
winlink1000OduAdmin OBJECT IDENTIFIER ::= { winlink1000Odu 1 }
winlink1000OduAdmProductType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ODU configuration description."
::= { winlink1000OduAdmin 1 }
winlink1000OduAdmHwRev OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ODU Hardware Version."
::= { winlink1000OduAdmin 2 }
winlink1000OduAdmSwRev OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ODU Software Version."
::= { winlink1000OduAdmin 3 }
winlink1000OduAdmLinkName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link Name. A change is effective immediately."
::= { winlink1000OduAdmin 4 }
winlink1000OduAdmResetCmd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset Command.
A set command with a value of 3 will cause a device reset.
HBS only: A set command with a value of 4 will cause a device reset for the entire sector.
The read value is always 0."
::= { winlink1000OduAdmin 5 }
winlink1000OduAdmAddres OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ODU IP address. A change is effective after reset.
The parameter is kept for backward compatibility.
Using the alternative parameter: winlink1000OduAdmIpParamsCnfg is recommended."
::= { winlink1000OduAdmin 6 }
winlink1000OduAdmMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ODU Subnet Mask. A change is effective after reset.
The parameter is kept for backward compatibility.
Using the alternative parameter: winlink1000OduAdmIpParamsCnfg is recommended."
::= { winlink1000OduAdmin 7 }
winlink1000OduAdmGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ODU default gateway. A change is effective after reset.
The parameter is kept for backward compatibility.
Using the alternative parameter: winlink1000OduAdmIpParamsCnfg is recommended."
::= { winlink1000OduAdmin 8 }
winlink1000OduAdmBroadcast OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter is reserved for the Manager application provided with the product."
::= { winlink1000OduAdmin 10 }
-- ###########################################################
-- ODU Admin Hosts Table
-- ###########################################################
winlink1000OduAdmHostsTable OBJECT-TYPE
SYNTAX SEQUENCE OF Winlink1000OduAdmHostsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Trap destinations table. Each trap destination is defined by an IP address and a UDP port.
Up to 10 addresses can be configured."
::= { winlink1000OduAdmin 12 }
winlink1000OduAdmHostsEntry OBJECT-TYPE
SYNTAX Winlink1000OduAdmHostsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Trap destinations table entry."
INDEX { winlink1000OduAdmHostsIndex }
::= { winlink1000OduAdmHostsTable 1 }
Winlink1000OduAdmHostsEntry ::= SEQUENCE {
winlink1000OduAdmHostsIndex
INTEGER,
winlink1000OduAdmHostsIp
IpAddress,
winlink1000OduAdmHostsPort
INTEGER,
winlink1000OduAdmHostsSecurityModel
INTEGER,
winlink1000OduAdmHostsUserName
DisplayString,
winlink1000OduAdmHostsPassword
DisplayString,
winlink1000OduAdmHostsIPv6
DisplayString
}
winlink1000OduAdmHostsIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Trap destinations table index."
::= { winlink1000OduAdmHostsEntry 1 }
winlink1000OduAdmHostsIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Trap destination IP address. A change is effective immediately."
::= { winlink1000OduAdmHostsEntry 2 }
winlink1000OduAdmHostsPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"UDP port of the trap destination. A change is effective immediately."
::= { winlink1000OduAdmHostsEntry 3 }
winlink1000OduAdmHostsSecurityModel OBJECT-TYPE
SYNTAX INTEGER {
snmpv1(1),
snmpv3(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Security model used for this trap generation."
::= { winlink1000OduAdmHostsEntry 4 }
winlink1000OduAdmHostsUserName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User name used to generate the snmpv3 trap."
::= { winlink1000OduAdmHostsEntry 5 }
winlink1000OduAdmHostsPassword OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Password used to generate the snmpv3 trap."
::= { winlink1000OduAdmHostsEntry 6 }
winlink1000OduAdmHostsIPv6 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Trap destination IPv6 address. A change is effective immediately."
::= { winlink1000OduAdmHostsEntry 7 }
winlink1000OduBuzzerAdminState OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls the activation of the buzzer while the unit is in install mode.
A change is effective immediately. The valid values are: disabled (0), enabledAuto (1), enabledConstantly(2), advancedAuto (3)."
::= { winlink1000OduAdmin 13 }
winlink1000OduProductId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter is reserved for the Manager application provided with the product."
::= { winlink1000OduAdmin 14 }
winlink1000OduReadCommunity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Read Community String. This parameter always returns ***** when retrieving its value.
It is used by the Manager application to change the Read Community String.
The SNMP agent accepts only encrypted values."
::= { winlink1000OduAdmin 15 }
winlink1000OduReadWriteCommunity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Read/Write Community String. This parameter always returns ***** when retrieving its value.
It is used by the Manager application to change the Read/Write Community String.
The SNMP agent accepts only encrypted values."
::= { winlink1000OduAdmin 16 }
winlink1000OduTrapCommunity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Trap Community String. This parameter is used by the Manager application to change the Trap Community String.
The SNMP agent accepts only encrypted values."
::= { winlink1000OduAdmin 17 }
winlink1000OduAdmSnmpAgentVersion OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Major version of the SNMP agent."
::= { winlink1000OduAdmin 18 }
winlink1000OduAdmRemoteSiteName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote site name. Returns the same value as sysLocation parameter of the remote site."
::= { winlink1000OduAdmin 19 }
winlink1000OduAdmSnmpAgentMinorVersion OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Minor version of the SNMP agent."
::= { winlink1000OduAdmin 20 }
winlink1000OduAdmLinkPassword OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link Password. This parameter always returns ***** when retrieving its value.
It is used by the Manager application to change the Link Password.
The SNMP agent accepts only encrypted values."
::= { winlink1000OduAdmin 21 }
winlink1000OduAdmSiteLinkPassword OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Site Link Password. This parameter always returns ***** when retrieving its value.
It is used by the Manager application to change the Link Password of the site.
The SNMP agent accepts only encrypted values."
::= { winlink1000OduAdmin 22 }
winlink1000OduAdmDefaultPassword OBJECT-TYPE
SYNTAX INTEGER {
default(1),
nonDefault(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter indicates if the current Link Password is the default password."
::= { winlink1000OduAdmin 23 }
winlink1000OduAdmConnectionType OBJECT-TYPE
SYNTAX INTEGER {
directConnection(1),
indirectConnection(2),
unknown(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter indicates if the Manager application is connected to the local ODU
or to the remote ODU over the air. A value of 'unknown' indicates community string mismatch."
::= { winlink1000OduAdmin 24 }
winlink1000OduAdmBackToFactorySettingsCmd OBJECT-TYPE
SYNTAX INTEGER {
withIP(1),
withoutIP(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Back to factory settings Command. A change is effective after reset.
The read value is always 0."
::= { winlink1000OduAdmin 25 }
winlink1000OduAdmIpParamsCnfg OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ODU IP address Configuration. The format is: |||"
::= { winlink1000OduAdmin 26 }
winlink1000OduAdmVlanID OBJECT-TYPE
SYNTAX INTEGER (0..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VLAN ID. Valid values are 1 to 4094.
Initial value is 0 meaning VLAN unaware."
::= { winlink1000OduAdmin 27 }
winlink1000OduAdmVlanPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VLAN Priority. 0 is lowest priority, 7 is highest priority."
::= { winlink1000OduAdmin 28 }
winlink1000OduAdmSN OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ODU Serial Number"
::= { winlink1000OduAdmin 29 }
winlink1000OduAdmProductName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the product name as it exists at EC"
::= { winlink1000OduAdmin 30 }
winlink1000OduAdmActivationKey OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Activates a general key."
::= { winlink1000OduAdmin 31 }
winlink1000OduAdmRmtPermittedOduType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mobile Application: permitted partner OduType."
::= { winlink1000OduAdmin 32 }
winlink1000OduAdmCpuID OBJECT-TYPE
SYNTAX INTEGER (0..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPU ID"
::= { winlink1000OduAdmin 33 }
winlink1000OduAdmOvrdCmd OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ability to perform special command in the ODU."
::= { winlink1000OduAdmin 34 }
winlink1000OduAdmLinkMode OBJECT-TYPE
SYNTAX INTEGER {
pmpHbs (1),
pmpHsu (2),
pmpHsuHyb (3),
pmpHbsHyb (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Unit PMP operation mode."
::= { winlink1000OduAdmin 35 }
winlink1000OduAdmActualConnectMode OBJECT-TYPE
SYNTAX INTEGER {
none (1),
ptp (2),
ptmp (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unit connected as part to ptp or ptmp."
::= { winlink1000OduAdmin 36 }
winlink1000OduAdmAES256Support OBJECT-TYPE
SYNTAX INTEGER {
notSupported (1),
supported (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"AES-256 security support indication."
::= { winlink1000OduAdmin 37 }
winlink1000OduAdmAES256State OBJECT-TYPE
SYNTAX INTEGER {
disabled (1),
enabled (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/Disable AES-256 security mode over the air link."
::= { winlink1000OduAdmin 38 }
winlink1000OduAdmAES256Status OBJECT-TYPE
SYNTAX INTEGER {
notOperating (1),
partiallyOperating (2),
operating (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"AES256 operating status"
::= { winlink1000OduAdmin 39 }
winlink1000OduAdmBatterySavingShutdownTime OBJECT-TYPE
SYNTAX INTEGER (0..1000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Battery Saving Shutdown Time in minutes, 0 till battery run out, -1 if not supported."
::= { winlink1000OduAdmin 40 }
winlink1000OduAdmWiFiPowerMode OBJECT-TYPE
SYNTAX INTEGER {
undefined (1),
powerON (2),
powerOFF (3),
alwaysON (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"WIFI unit power mode."
::= { winlink1000OduAdmin 41 }
winlink1000OduAdmShutdownTimer OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Shutdown Timer in seconds."
::= { winlink1000OduAdmin 42 }
winlink1000OduAdmGPSState OBJECT-TYPE
SYNTAX INTEGER {
undefined (1),
notSynchronized (2),
fixed (3),
shortCircuit (4),
faulty (5),
synchronized (6),
synchronizedGlonass (7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"GPS state"
::= { winlink1000OduAdmin 43 }
winlink1000OduAdmTemperatureC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The temperature (Celsius) inside the Board."
::= { winlink1000OduAdmin 44 }
winlink1000OduAdmIPStackMode OBJECT-TYPE
SYNTAX INTEGER {
v4 (1),
v6 (2),
v4andv6 (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP stack mode."
::= { winlink1000OduAdmin 45 }
winlink1000OduAdmIPv6ParamsCnfg OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ODU IPv6 address Configuration. The format is: |||"
::= { winlink1000OduAdmin 46 }
winlink1000OduAdmIPv6Address OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ODU IPv6 address."
::= { winlink1000OduAdmin 47 }
winlink1000OduAdmIPv6Prefix OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ODU IPv6 subnet mask."
::= { winlink1000OduAdmin 48 }
winlink1000OduAdmIPv6DefaultGateWay OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ODU IPv6 default gateway."
::= { winlink1000OduAdmin 49 }
winlink1000OduAdmPowerConsumption OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power Consumption (mWatt)"
::= { winlink1000OduAdmin 50 }
-- ###########################################################
-- ODU Wifi
-- ###########################################################
winlink1000OduAdmWifi OBJECT IDENTIFIER ::= { winlink1000OduAdmin 51 }
winlink1000OduAdmWifiChannel OBJECT-TYPE
SYNTAX INTEGER (1..11)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wifi Channel"
::= { winlink1000OduAdmWifi 1 }
winlink1000OduAdmWifiTxPower OBJECT-TYPE
SYNTAX INTEGER (11..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wifi TX Power"
::= { winlink1000OduAdmWifi 2 }
winlink1000OduAdmWifiSSID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wifi SSID"
::= { winlink1000OduAdmWifi 3 }
winlink1000OduAdmWifiSecurityType OBJECT-TYPE
SYNTAX INTEGER {
open (1),
wep (2),
wpa2 (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wifi Security type"
::= { winlink1000OduAdmWifi 4 }
winlink1000OduAdmWifiPassword OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wifi Password"
::= { winlink1000OduAdmWifi 5 }
winlink1000OduAdmWifiNetwork OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wifi Network"
::= { winlink1000OduAdmWifi 6 }
winlink1000OduAdmWifiRssi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wifi RSSI"
::= { winlink1000OduAdmWifi 7 }
winlink1000OduAdmWifiStationMAC OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wifi Station MAC"
::= { winlink1000OduAdmWifi 8 }
winlink1000OduAdmWifiRestart OBJECT-TYPE
SYNTAX INTEGER (1)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A set command with a value of 1 will cause a Wifi restart.
The read value is always 0."
::= { winlink1000OduAdmWifi 9 }
winlink1000OduAdmWifiApStatus OBJECT-TYPE
SYNTAX INTEGER {
off (1),
on (2),
connected (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wifi AP Status"
::= { winlink1000OduAdmWifi 10 }
winlink1000OduAdmBsaOperationMode OBJECT-TYPE
SYNTAX INTEGER {
inactive (1),
hbsTracking (2),
hsuAlignment (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BSA Operation Mode"
::= { winlink1000OduAdmin 52 }
winlink1000OduAdmMngConnection OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Management Connection"
::= { winlink1000OduAdmin 53 }
winlink1000OduAdm1588TCSupport OBJECT-TYPE
SYNTAX INTEGER {
notSupported (1),
supported (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates that 1588TC license activated"
::= { winlink1000OduAdmin 54 }
winlink1000OduAdmSyncESupport OBJECT-TYPE
SYNTAX INTEGER {
notSupported (1),
supported (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ndicates that SyncE license activated"
::= { winlink1000OduAdmin 55 }
winlink1000OduAdmRadioRev OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Radio Revision"
::= { winlink1000OduAdmin 56 }
winlink1000OduAdmProductRev OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Product Revision"
::= { winlink1000OduAdmin 57 }
winlink1000OduAdmPMPSUSupport OBJECT-TYPE
SYNTAX INTEGER {
notSupported (1),
supported (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates that PMP SU license is activated"
::= { winlink1000OduAdmin 58 }
winlink1000OduAdmManagerDownloadURL OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the URL from which management tool can be downloaded"
::= { winlink1000OduAdmin 59 }
winlink1000OduAdmAntennaDescription OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The is a description of the antenna connected to the ODU"
::= { winlink1000OduAdmin 60 }
winlink1000OduAdmSwCapabilities OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is used to describe which Software Capabilities the current ODU supports"
::= { winlink1000OduAdmin 61 }
-- ###########################################################
-- ODU Service
-- ###########################################################
winlink1000OduService OBJECT IDENTIFIER ::= { winlink1000Odu 2 }
winlink1000OduSrvMode OBJECT-TYPE
SYNTAX INTEGER {
installMode (1),
normalMode (2),
slaveMode (3),
tempInstallMode (4),
inactiveMode (5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System mode. The only values that can be set are installMode and slaveMode;
normalMode reserved to the Manager application provided with the product.
A change is effective after link re-synchronization."
::= { winlink1000OduService 1 }
winlink1000OduSrvBridging OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridging Mode. Valid values are: disabled (0), enabled (1)."
::= { winlink1000OduService 3 }
-- ###########################################################
-- ODU Ring Topology
-- ###########################################################
winlink1000OduServiceRingTopology OBJECT IDENTIFIER ::= { winlink1000OduService 4 }
winlink1000OduSrvRingLinkMode OBJECT-TYPE
SYNTAX INTEGER {
independentLink (1),
nonRpl (2),
rpl (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mode of the link regarding ring topology."
::= { winlink1000OduServiceRingTopology 1 }
winlink1000OduSrvRingTopologySupported OBJECT-TYPE
SYNTAX INTEGER {
notSupported (1),
supported (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ring Topology, options are: supported, not supported"
::= { winlink1000OduServiceRingTopology 2 }
winlink1000OduSrvRingVlanIdTable OBJECT-TYPE
SYNTAX SEQUENCE OF Winlink1000OduSrvRingVlanIdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Ring VLAN IDs table."
::= { winlink1000OduServiceRingTopology 3 }
winlink1000OduSrvRingVlanIdEntry OBJECT-TYPE
SYNTAX Winlink1000OduSrvRingVlanIdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VLAN ID of the internal ring messages. Valid values are 1 to 4094.
Initial value is 0 meaning VLAN unaware."
INDEX { winlink1000OduSrvRingVlanIdIndex }
::= { winlink1000OduSrvRingVlanIdTable 1 }
Winlink1000OduSrvRingVlanIdEntry ::= SEQUENCE {
winlink1000OduSrvRingVlanIdIndex
INTEGER,
winlink1000OduSrvRingVlanId
INTEGER
}
winlink1000OduSrvRingVlanIdIndex OBJECT-TYPE
SYNTAX INTEGER (0..3)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index of VLAN ID of the internal ring messages."
::= { winlink1000OduSrvRingVlanIdEntry 1 }
winlink1000OduSrvRingVlanId OBJECT-TYPE
SYNTAX INTEGER (0..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VLAN ID of the internal ring messages. Valid values are 1 to 4094.
Initial value is 0 meaning VLAN unaware."
::= { winlink1000OduSrvRingVlanIdEntry 2 }
winlink1000OduSrvRingEthStatus OBJECT-TYPE
SYNTAX INTEGER {
unblocked(1),
blocked(2),
notApplicable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Represents the Ethernet service blocking state of a Rings link"
::= { winlink1000OduServiceRingTopology 4 }
winlink1000OduSrvRingMaxAllowedTimeFromLastRpm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the minimal time (in ms) required for determination of ring failure."
::= { winlink1000OduServiceRingTopology 5 }
winlink1000OduSrvRingWTR OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the minimal time (in ms) required for ring recovery."
::= { winlink1000OduServiceRingTopology 6 }
-- ###########################################################
-- ODU QoS
-- ###########################################################
winlink1000OduServiceQoS OBJECT IDENTIFIER ::= { winlink1000OduService 5 }
winlink1000OduSrvQoSMode OBJECT-TYPE
SYNTAX INTEGER {
notSupported (1),
notActive (2),
classVlan (3),
classDiffserv (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mode of QoS feature."
::= { winlink1000OduServiceQoS 1 }
winlink1000OduSrvQoSConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Winlink1000OduSrvQoSConfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QoS configuration table."
::= { winlink1000OduServiceQoS 2 }
winlink1000OduSrvQoSConfEntry OBJECT-TYPE
SYNTAX Winlink1000OduSrvQoSConfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QoS configuration table."
INDEX { winlink1000OduSrvQoSConfIndex }
::= { winlink1000OduSrvQoSConfTable 1 }
Winlink1000OduSrvQoSConfEntry ::= SEQUENCE {
winlink1000OduSrvQoSConfIndex
INTEGER,
winlink1000OduSrvConfVlanQGroups
INTEGER,
winlink1000OduSrvConfDiffservQGroups
INTEGER,
winlink1000OduSrvConfQueMir
INTEGER,
winlink1000OduSrvConfQueWeight
INTEGER
}
winlink1000OduSrvQoSConfIndex OBJECT-TYPE
SYNTAX INTEGER (0..3)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index of QoS Configuration."
::= { winlink1000OduSrvQoSConfEntry 1 }
winlink1000OduSrvConfVlanQGroups OBJECT-TYPE
SYNTAX INTEGER (0..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Frames classification according to VLAN Priority IDs."
::= { winlink1000OduSrvQoSConfEntry 2 }
winlink1000OduSrvConfDiffservQGroups OBJECT-TYPE
SYNTAX INTEGER (0..48)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Frames classification according to Diffserv."
::= { winlink1000OduSrvQoSConfEntry 3 }
winlink1000OduSrvConfQueMir OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Desired Private MIR."
::= { winlink1000OduSrvQoSConfEntry 4 }
winlink1000OduSrvConfQueWeight OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QoS queueu's weights in percent."
::= { winlink1000OduSrvQoSConfEntry 5 }
winlink1000OduSrvQoSVlanQGroupsSetStr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Frames classification according to VLAN IDs string for set."
::= { winlink1000OduServiceQoS 3 }
winlink1000OduSrvQoSDiffservQGroupsSetStr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Frames classification according to Diffserv IDs string for set."
::= { winlink1000OduServiceQoS 4 }
winlink1000OduSrvQoSMaxRTQuePercent OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximal percent for RT & NRT queues."
::= { winlink1000OduServiceQoS 5 }
-- ###########################################################
-- ODU VLAN Configuration
-- ###########################################################
winlink1000OduServiceVlan OBJECT IDENTIFIER ::= { winlink1000OduService 6 }
winlink1000OduSrvVlanSupport OBJECT-TYPE
SYNTAX INTEGER {
notSupported (1),
supported(2),
available(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ODU Ethernet port VLAN support and configuration availability indication.
1 - ODU VLAN Functionality Not Supported
2 - ODU VLAN Functionality Supported
3 - ODU VLAN Functionality Supported and Available"
::= { winlink1000OduServiceVlan 1 }
winlink1000OduSrvVlanIngressMode OBJECT-TYPE
SYNTAX INTEGER {
transparent (1),
untagAll (2),
filter (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ODU Ethernet port ingress VLAN mode."
::= { winlink1000OduServiceVlan 2 }
winlink1000OduSrvVlanEgressMode OBJECT-TYPE
SYNTAX INTEGER {
transparent (1),
tag (2),
provider (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ODU Ethernet port egress VLAN mode."
::= { winlink1000OduServiceVlan 3 }
winlink1000OduSrvEgressTag OBJECT-TYPE
SYNTAX INTEGER (0..40947)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ODU ethernet port egress VLAN tag.
Right most digit is Vlan priority (0-7),
other digits compose Vlan Id (2-4094)"
::= { winlink1000OduServiceVlan 4 }
winlink1000OduSrvEgressProviderTag OBJECT-TYPE
SYNTAX INTEGER (0..40947)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ODU ethernet port egress Provider VLAN tag.
Right most digit is Vlan priority (0-7),
other digits compose Vlan Id (2-4094)"
::= { winlink1000OduServiceVlan 5 }
winlink1000OduSrvVlanIngressAllowedVIDs OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ODU ethernet port VLAN IDs that will not be filtered on ingress.
w|w|w|w|w|w|w|w| ( where w = {0-4094} and w != 1 )"
::= { winlink1000OduServiceVlan 6 }
winlink1000OduSrvVlanDisable OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Disable VLAN functionality. The following values can be set:
3 - Disable ODU & IDU VLAN Configurations."
::= { winlink1000OduServiceVlan 7 }
winlink1000OduServiceVlanProviderListTPIDstr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Holds the possible Provider TPIDs."
::= { winlink1000OduServiceVlan 8 }
-- ###########################################################
-- ODU Ethernet
-- ###########################################################
winlink1000OduEthernet OBJECT IDENTIFIER ::= { winlink1000Odu 3 }
winlink1000OduEthernetRemainingRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Ethernet bandwidth in bps."
::= { winlink1000OduEthernet 1 }
-- ###########################################################
-- ODU Ethernet Interface Table
-- ###########################################################
winlink1000OduEthernetIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Winlink1000OduEthernetIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ODU Ethernet Interface table."
::= { winlink1000OduEthernet 2 }
winlink1000OduEthernetIfEntry OBJECT-TYPE
SYNTAX Winlink1000OduEthernetIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ODU Ethernet Interface table entry."
INDEX { winlink1000OduEthernetIfIndex }
::= { winlink1000OduEthernetIfTable 1 }
Winlink1000OduEthernetIfEntry ::= SEQUENCE {
winlink1000OduEthernetIfIndex
INTEGER,
winlink1000OduEthernetIfAddress
DisplayString,
winlink1000OduEthernetIfAdminStatus
INTEGER,
winlink1000OduEthernetIfOperStatus
INTEGER,
winlink1000OduEthernetIfFailAction
INTEGER,
winlink1000OduEthernetIf1588v2PTPEventRXRate
INTEGER,
winlink1000OduEthernetIf1588v2PTPEventTXRate
INTEGER
}
winlink1000OduEthernetIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ODU Ethernet Interface Index."
::= { winlink1000OduEthernetIfEntry 1 }
winlink1000OduEthernetIfAddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ODU MAC address."
::= { winlink1000OduEthernetIfEntry 5 }
winlink1000OduEthernetIfAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
portAutoSense(1),
portAutoSense100Mbps(5),
forceHalfDuplex10Mbps(10),
forceFullDuplex10Mbps(11),
forceHalfDuplex100Mbps(15),
forceFullDuplex100Mbps(16),
forceFullDuplex1000Mbps(21),
disablePoePort(254),
disablePort(255)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Required state of the interface."
::= { winlink1000OduEthernetIfEntry 6 }
winlink1000OduEthernetIfOperStatus OBJECT-TYPE
SYNTAX INTEGER {
notConnected(1),
connectedHalfDuplex10Mbps(10),
connectedFullDuplex10Mbps(11),
connectedHalfDuplex100Mbps(15),
connectedFullDuplex100Mbps(16),
connectedHalfDuplex1000Mbps(20),
connectedFullDuplex1000Mbps(21),
unknown(65535)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current operational state of the interface."
::= { winlink1000OduEthernetIfEntry 7 }
winlink1000OduEthernetIfFailAction OBJECT-TYPE
SYNTAX INTEGER {
faNoAction(1),
faForceHalfDuplex10Mbps(10),
faForceFullDuplex10Mbps(11),
faDisablePort(255)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Failure action of the interface."
::= { winlink1000OduEthernetIfEntry 8 }
winlink1000OduEthernetIf1588v2PTPEventRXRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"For debug use"
::= { winlink1000OduEthernetIfEntry 9 }
winlink1000OduEthernetIf1588v2PTPEventTXRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"For debug use"
::= { winlink1000OduEthernetIfEntry 10 }
winlink1000OduEthernetNumOfPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of ODU network interfaces."
::= { winlink1000OduEthernet 3 }
winlink1000OduEthernetGbeSupported OBJECT-TYPE
SYNTAX INTEGER {notSupported(1), supported(2)}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Supported Giga bit Ethernet in ODU."
::= { winlink1000OduEthernet 4 }
winlink1000OduEthernetSfpProperties OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sfp port properties."
::= { winlink1000OduEthernet 5 }
-- ###########################################################
-- ODU Bridge
-- ###########################################################
winlink1000OduBridge OBJECT IDENTIFIER ::= { winlink1000Odu 4 }
-- ###########################################################
-- ODU Bridge Base
-- ###########################################################
winlink1000OduBridgeBase OBJECT IDENTIFIER ::= { winlink1000OduBridge 1 }
-- ###########################################################
-- ODU Bridge Ports Table
-- ###########################################################
winlink1000OduBridgeBasePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Winlink1000OduBridgeBasePortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ODU Bridge Ports table."
::= { winlink1000OduBridgeBase 4 }
winlink1000OduBridgeBasePortEntry OBJECT-TYPE
SYNTAX Winlink1000OduBridgeBasePortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ODU Bridge Ports table entry."
INDEX { winlink1000OduBridgeBasePortIndex }
::= { winlink1000OduBridgeBasePortTable 1 }
Winlink1000OduBridgeBasePortEntry ::= SEQUENCE {
winlink1000OduBridgeBasePortIndex
INTEGER,
winlink1000OduBridgeBaseIfIndex
INTEGER
}
winlink1000OduBridgeBasePortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ODU Bridge Port Number."
::= { winlink1000OduBridgeBasePortEntry 1 }
winlink1000OduBridgeBaseIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IfIndex corresponding to ODU Bridge port."
::= { winlink1000OduBridgeBasePortEntry 2 }
-- ###########################################################
-- ODU Bridge Tp
-- ###########################################################
winlink1000OduBridgeTp OBJECT IDENTIFIER ::= { winlink1000OduBridge 4 }
winlink1000OduBridgeTpMode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ODU bridge mode.
A change is effective after reset. Valid values: hubMode (0), bridgeMode (1)."
::= { winlink1000OduBridgeTp 101 }
-- ###########################################################
-- ODU Transparent Bridge Ports Table
-- ###########################################################
winlink1000OduBridgeTpPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Winlink1000OduBridgeTpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ODU Transparent Bridge Ports table."
::= { winlink1000OduBridgeTp 3 }
winlink1000OduBridgeTpPortEntry OBJECT-TYPE
SYNTAX Winlink1000OduBridgeTpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ODU Transparent Bridge Ports table entry."
INDEX { winlink1000OduBridgeTpPortIndex }
::= { winlink1000OduBridgeTpPortTable 1 }
Winlink1000OduBridgeTpPortEntry ::= SEQUENCE {
winlink1000OduBridgeTpPortIndex
INTEGER,
winlink1000OduBridgeTpPortInFrames
Counter,
winlink1000OduBridgeTpPortOutFrames
Counter,
winlink1000OduBridgeTpPortInBytes
Counter,
winlink1000OduBridgeTpPortOutBytes
Counter
}
winlink1000OduBridgeTpPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ODU Transparent Bridge Port Number."
::= { winlink1000OduBridgeTpPortEntry 1 }
winlink1000OduBridgeTpPortInFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of frames received by this port."
::= { winlink1000OduBridgeTpPortEntry 3 }
winlink1000OduBridgeTpPortOutFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of frames transmitted by this port."
::= { winlink1000OduBridgeTpPortEntry 4 }
winlink1000OduBridgeTpPortInBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of bytes received by this port."
::= { winlink1000OduBridgeTpPortEntry 101 }
winlink1000OduBridgeTpPortOutBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of bytes transmitted by this port."
::= { winlink1000OduBridgeTpPortEntry 102 }
winlink1000OduBridgeConfigMode OBJECT-TYPE
SYNTAX INTEGER{
enable (1),
disable (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ODU bridge configuration mode"
::= { winlink1000OduBridgeTp 102 }
-- ###########################################################
-- ODU Air
-- ###########################################################
winlink1000OduAir OBJECT IDENTIFIER ::= { winlink1000Odu 5 }
winlink1000OduAirFreq OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Installation Center Frequency. Valid values are product dependent. A change is effective after link re-synchronization."
::= { winlink1000OduAir 1 }
winlink1000OduAirDesiredRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Deprecated parameter, actual behavior is read-only.
Required Air Rate. For Channel Bandwidth of 20, 10, 5 MHz divide the value by 1, 2, 4 respectively."
::= { winlink1000OduAir 2 }
winlink1000OduAirSSID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reserved for the Manager application provided with the product.
The Sector ID in Point-To-Multi-Point systems."
::= { winlink1000OduAir 3 }
winlink1000OduAirTxPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Required Transmit power in dBm . This is a nominal value while the actual transmit power includes additional attenuation.
The min and max values are product specific. A change is effective immediately."
::= { winlink1000OduAir 4 }
winlink1000OduAirSesState OBJECT-TYPE
SYNTAX INTEGER {
sessionDown (1),
basicRate (2),
active (3),
installation (4),
scanning (5),
probing (6),
transmitting (7),
activeWithDefaultEncryptionKey (8),
installationWithDefaultEncryptionKey (9),
bitFailed (10),
activeWithVersionsMismatch (11),
installationWithVersionsMismatch (12),
inactive (13),
iduIncompatible (14),
spectrumAnalysis (15)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Link State. The value is active (3) during normal operation."
::= { winlink1000OduAir 5 }
winlink1000OduAirMstrSlv OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter indicates if the device was automatically selected into the radio link master or slave.
The value is undefined if there is no link.
The value is relevant only for point to point systems."
::= { winlink1000OduAir 6 }
winlink1000OduAirResync OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this parameter to 1 will cause the link to restart the synchronization process."
::= { winlink1000OduAir 8 }
-- ###########################################################
-- ODU Air Perf
-- ###########################################################
winlink1000OduAirPerf OBJECT IDENTIFIER ::= { winlink1000OduAir 9 }
winlink1000OduAirRxPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Received Signal Strength in dBm. Relevant only for point to point systems."
::= { winlink1000OduAirPerf 1 }
winlink1000OduAirTotalFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of radio frames."
::= { winlink1000OduAirPerf 2 }
winlink1000OduAirBadFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of received radio frames with CRC error. The value is relevant only for point to point systems ."
::= { winlink1000OduAirPerf 3 }
winlink1000OduAirCurrentRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Deprecated parameter. Actual rate of the air interface in Mbps.
For Channel Bandwidth of 20, 10, 5 MHz divide the value by 1, 2, 4 respectively."
::= { winlink1000OduAirPerf 4 }
winlink1000OduAirCurrentRateIdx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index of current air rate."
::= { winlink1000OduAirPerf 5 }
winlink1000OduAirChainsRxPower OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Received Signal Strength of Cpe chains in dBm.
Chain 1 RSS: (1 Byte)
Chain 2 RSS: (1 Byte)
Chain 3 RSS: (1 Byte)"
::= { winlink1000OduAirPerf 6 }
winlink1000OduAirCurrentRateCBW OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CBW of current air rate."
::= { winlink1000OduAirPerf 7 }
winlink1000OduAirCurrentRateGI OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"GI of current air rate."
::= { winlink1000OduAirPerf 8 }
winlink1000OduAirTxPower36 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Deprecated parameter. Actual behavior is read-only."
::= { winlink1000OduAir 10 }
winlink1000OduAirTxPower48 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Deprecated parameter. Actual behavior is read-only."
::= { winlink1000OduAir 11 }
winlink1000OduAirCurrentTxPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Transmit Power in dBm. This is a nominal value while the actual transmit power includes additional attenuation."
::= { winlink1000OduAir 12 }
winlink1000OduAirMinFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Minimum center frequency in MHz."
::= { winlink1000OduAir 13 }
winlink1000OduAirMaxFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum center frequency in MHz."
::= { winlink1000OduAir 14 }
winlink1000OduAirFreqResolution OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Center Frequency resolution.
Measured in MHz if value < 100, otherwise in KHz."
::= { winlink1000OduAir 15 }
winlink1000OduAirCurrentFreq OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Center Frequency.
Measured in MHz if center frequency resolution value < 100, otherwise in KHz."
::= { winlink1000OduAir 16 }
winlink1000OduAirNumberOfChannels OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of channels that can be used."
::= { winlink1000OduAir 17 }
-- ###########################################################
-- Channels Table
-- ###########################################################
winlink1000OduAirChannelsTable OBJECT-TYPE
SYNTAX SEQUENCE OF Winlink1000OduAirChannelsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of channels used by automatic channels selection (ACS)."
::= { winlink1000OduAir 18 }
winlink1000OduAirChannelsEntry OBJECT-TYPE
SYNTAX Winlink1000OduAirChannelsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ACS channels table entry."
INDEX { winlink1000OduAirChannelsIndex }
::= { winlink1000OduAirChannelsTable 1 }
Winlink1000OduAirChannelsEntry ::= SEQUENCE {
winlink1000OduAirChannelsIndex
INTEGER,
winlink1000OduAirChannelsFrequency
INTEGER,
winlink1000OduAirChannelsOperState
INTEGER,
winlink1000OduAirChannelsAvail
INTEGER,
winlink1000OduAirChannelsDefaultFreq
INTEGER
}
winlink1000OduAirChannelsIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel Index."
::= { winlink1000OduAirChannelsEntry 1 }
winlink1000OduAirChannelsFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel frequency in MHz."
::= { winlink1000OduAirChannelsEntry 2 }
winlink1000OduAirChannelsOperState OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Channel state. Can be set by the user.
Automatic Channel Selection uses channels that are AirChannelsOperState enabled and AirChannelsAvail enabled.
A change is effective after link re-synchronization. Valid values: disabled (0), enabled (1).
Rewriteable only in Point-To-Point products."
::= { winlink1000OduAirChannelsEntry 3 }
winlink1000OduAirChannelsAvail OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel state. Product specific and cannot be changed by the user.
Automatic Channel Selection uses channels that are AirChannelsOperState enabled and AirChannelsAvail enabled.
Valid values: disabled (0), enabled (1)."
::= { winlink1000OduAirChannelsEntry 4 }
winlink1000OduAirChannelsDefaultFreq OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Default channel's availability for all CBWs.
The valid values are: forbidden (0), available (1)."
::= { winlink1000OduAirChannelsEntry 5 }
winlink1000OduAirDfsState OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Radar detection state. Valid values: disabled (0), enabled (1)."
::= { winlink1000OduAir 19 }
winlink1000OduAirAutoChannelSelectionState OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Deprecated parameter. Indicating Automatic Channel Selection availability at current channel bandwidth.
Valid values: disabled (0), enabled (1)."
::= { winlink1000OduAir 20 }
winlink1000OduAirEnableTxPower OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicating Transmit power configuration enabled or disabled."
::= { winlink1000OduAir 21 }
winlink1000OduAirMinTxPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Minimum Transmit power in dBm."
::= { winlink1000OduAir 22 }
-- ###########################################################
-- Max Tx Power Table
-- ###########################################################
winlink1000OduAirMaxTxPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF Winlink1000OduAirMaxTxPowerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Maximum transmit power per air rate, in dBm."
::= { winlink1000OduAir 23 }
winlink1000OduAirMaxTxPowerEntry OBJECT-TYPE
SYNTAX Winlink1000OduAirMaxTxPowerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Maximum Transmit power table entry."
INDEX { winlink1000OduAirMaxTxPowerIndex }
::= { winlink1000OduAirMaxTxPowerTable 1 }
Winlink1000OduAirMaxTxPowerEntry ::= SEQUENCE {
winlink1000OduAirMaxTxPowerIndex
INTEGER,
winlink1000OduAirMaxTxPower
INTEGER
}
winlink1000OduAirMaxTxPowerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Air interface rate index."
::= { winlink1000OduAirMaxTxPowerEntry 1 }
winlink1000OduAirMaxTxPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum Transmit power in dBm."
::= { winlink1000OduAirMaxTxPowerEntry 2 }
winlink1000OduAirChannelBandwidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Channel bandwidth in KHz. A change is effective after reset."
::= { winlink1000OduAir 24 }
-- ###########################################################
-- Channel BW Table
-- ###########################################################
winlink1000OduAirChannelBWTable OBJECT-TYPE
SYNTAX SEQUENCE OF Winlink1000OduAirChannelBWEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Channel Bandwidths table."
::= { winlink1000OduAir 25 }
winlink1000OduAirChannelBWEntry OBJECT-TYPE
SYNTAX Winlink1000OduAirChannelBWEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Channel Bandwidth table entry."
INDEX { winlink1000OduAirChannelBWIndex }
::= { winlink1000OduAirChannelBWTable 1 }
Winlink1000OduAirChannelBWEntry ::= SEQUENCE {
winlink1000OduAirChannelBWIndex
INTEGER,
winlink1000OduAirChannelBWAvail
INTEGER,
winlink1000OduAirChannelsAdminState
DisplayString,
winlink1000OduAirChannelBWHSSATDDConflictPerCBW
INTEGER,
winlink1000OduAirChannelBWMinRatioForSupporting
INTEGER,
winlink1000OduAirChannelBWMaxRatioForSupporting
INTEGER
}
winlink1000OduAirChannelBWIndex OBJECT-TYPE
SYNTAX INTEGER {
channelBW5MHz(1),
channelBW10MHz(2),
channelBW20MHz(3),
channelBW40MHz(4),
channelBW80MHz(5),
channelBW7MHz(6),
channelBW14MHz(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel Bandwidth index."
::= { winlink1000OduAirChannelBWEntry 1 }
winlink1000OduAirChannelBWAvail OBJECT-TYPE
SYNTAX INTEGER {
notSupported(1),
supportedManual(2),
supportedWithACS(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel Bandwidth availability, product specific.
Options are: Not supported, supported with manual channel selection, supported with Automatic Channel Selection."
::= { winlink1000OduAirChannelBWEntry 2 }
winlink1000OduAirChannelsAdminState OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channels' availability per CBW."
::= { winlink1000OduAirChannelBWEntry 3 }
winlink1000OduAirChannelBWHSSATDDConflictPerCBW OBJECT-TYPE
SYNTAX INTEGER {
noConflict(1),
conflictSingle(2),
conflictDual(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indication for possible Link drop per CBW due to conflict between HSS and ATDD."
::= { winlink1000OduAirChannelBWEntry 4 }
winlink1000OduAirChannelBWMinRatioForSupporting OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Minimal TX ratio that may be used by the HSM and still enable proper operation of the aforementioned CBW."
::= { winlink1000OduAirChannelBWEntry 5 }
winlink1000OduAirChannelBWMaxRatioForSupporting OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximal TX ratio that may be used by the HSM and still enable proper operation of the aforementioned CBW."
::= { winlink1000OduAirChannelBWEntry 6 }
winlink1000OduAirRFD OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current radio frame duration in microseconds."
::= { winlink1000OduAir 26 }
-- ###########################################################
-- Available Rates Table
-- ###########################################################
winlink1000OduAirRatesTable OBJECT-TYPE
SYNTAX SEQUENCE OF Winlink1000OduAirRatesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Air Rate indexes table for current channel bandwidth."
::= { winlink1000OduAir 27 }
winlink1000OduAirRatesEntry OBJECT-TYPE
SYNTAX Winlink1000OduAirRatesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Air Rate indexes table entry."
INDEX { winlink1000OduAirRatesIndex }
::= { winlink1000OduAirRatesTable 1 }
Winlink1000OduAirRatesEntry ::= SEQUENCE {
winlink1000OduAirRatesIndex
INTEGER,
winlink1000OduAirRatesAvail
INTEGER
}
winlink1000OduAirRatesIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Air Rate index."
::= { winlink1000OduAirRatesEntry 1 }
winlink1000OduAirRatesAvail OBJECT-TYPE
SYNTAX INTEGER {
rateNotAvailable(1),
rateAvailable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Air Rate availability, depending on air interface conditions."
::= { winlink1000OduAirRatesEntry 2 }
winlink1000OduAirDesiredRateIdx OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Required Air Rate index. 0 reserved for Adaptive Rate.
A change is effective immediately after Set operation to the master side
while the link is up."
::= { winlink1000OduAir 28 }
winlink1000OduAirLinkDistance OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link distance in meters.
A value of -1 indicates an illegal value and is also used when a link is not established."
::= { winlink1000OduAir 29 }
winlink1000OduAirLinkWorkingMode OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
normal(2),
fullCompatibilityRemoteUpgradeAvailable(3),
fullCompatibilityLocalUpgradeAvailable(4),
restrictedCompatibilityRemoteUpgradeRecomended(5),
restrictedCompatibilityLocalUpgradeRecomended(6),
softwareUpgradeRemoteUpgradeRequired(7),
softwareUpgradeLocalUpgradeRequired(8),
versionsIncompatibilityRemoteUpgradeRequired(9),
versionsIncompatibilityLocalUpgradeRequired(10)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link working mode as a result of comparing versions of both sides of the link.
Possible modes are: Unknown - no link, Normal - versions on both sides are identical with full compatibility,
with restricted compatibility, or versions on both sides are different with software upgrade or versions incompatibility."
::= { winlink1000OduAir 30 }
winlink1000OduAirMajorLinkIfVersion OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Major link interface version"
::= { winlink1000OduAir 31 }
winlink1000OduAirMinorLinkIfVersion OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Minor link interface version"
::= { winlink1000OduAir 32 }
winlink1000OduAirHss OBJECT IDENTIFIER ::= { winlink1000OduAir 40 }
winlink1000OduAirHssDesiredOpState OBJECT-TYPE
SYNTAX INTEGER {
notSupported(1),
independentUnit(2),
hubSyncMaster(3),
hubSyncClientContinueTx(4),
hubSyncClientDisableTx(5),
gpsSync(6),
independentSyncUnit-ISU(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Required Hub Site Synchronization operating state.
For HssSyncUnits : For hssISU :[2,7] ,For hssGSU :[2,6]
For HBS: [2,3,4,5]"
::= { winlink1000OduAirHss 1 }
winlink1000OduAirHssCurrentOpState OBJECT-TYPE
SYNTAX INTEGER {
notSupported(1),
independentUnit(2),
hubSyncMaster(3),
hubSyncClientContinueTx(4),
hubSyncClientDisableTx(5),
gpsSync(6),
independentSyncUnit-ISU(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Hub Site Synchronization operating state."
::= { winlink1000OduAirHss 2 }
winlink1000OduAirHssSyncStatus OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
notSynchronized(2),
synchronized(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hub Site Synchronization sync status."
::= { winlink1000OduAirHss 3 }
winlink1000OduAirHssExtPulseStatus OBJECT-TYPE
SYNTAX INTEGER {
notDetected(1),
generating(2),
generatingAndDetected(3),
generatingAndImproperDetected(4),
detected(5),
improperDetected(6),
multipleSourcesDetected(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hub Site Synchronization external pulse detection status.
In GSS mode:
if generating then 1PSP is auto generated by the GSS Unit.
if generatingAndDetecting then 1PSP is generated by GPS satellites signal."
::= { winlink1000OduAirHss 4 }
winlink1000OduAirHssExtPulseType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
typeA(2),
typeB(3),
typeC(4),
typeD(5),
typeE(6),
typeF(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hub Site Synchronization external pulse type."
::= { winlink1000OduAirHss 5 }
winlink1000OduAirHssDesiredExtPulseType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
typeA(2),
typeB(3),
typeC(4),
typeD(5),
typeE(6),
typeF(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hub Site Synchronization required external pulse type. Valid values for read write:
{typeA(2),typeB(3),typeC(4),typeD(5),typeE(6),typeF(7)}. Valid value for read only:
{notApplicable(1)}."
::= { winlink1000OduAirHss 6 }
-- ###########################################################
-- HSS Radio Frame Pattern Table
-- ###########################################################
winlink1000OduAirHssRfpTable OBJECT-TYPE
SYNTAX SEQUENCE OF Winlink1000OduAirHssRfpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ODU Radio Frame Patterns (RFP) Table."
::= { winlink1000OduAirHss 7 }
winlink1000OduAirHssRfpEntry OBJECT-TYPE
SYNTAX Winlink1000OduAirHssRfpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ODU RFP Table entry."
INDEX { winlink1000OduAirHssRfpIndex }
::= { winlink1000OduAirHssRfpTable 1 }
Winlink1000OduAirHssRfpEntry ::= SEQUENCE {
winlink1000OduAirHssRfpIndex
INTEGER,
winlink1000OduAirHssRfpEthChannelBW5MHz
INTEGER,
winlink1000OduAirHssRfpTdmChannelBW5MHz
INTEGER,
winlink1000OduAirHssRfpEthChannelBW10MHz
INTEGER,
winlink1000OduAirHssRfpTdmChannelBW10MHz
INTEGER,
winlink1000OduAirHssRfpEthChannelBW20MHz
INTEGER,
winlink1000OduAirHssRfpTdmChannelBW20MHz
INTEGER,
winlink1000OduAirHssRfpEthChannelBW40MHz
INTEGER,
winlink1000OduAirHssRfpTdmChannelBW40MHz
INTEGER,
winlink1000OduAirHssRfpEthChannelBW80MHz
INTEGER,
winlink1000OduAirHssRfpEthChannelBW7MHz
INTEGER,
winlink1000OduAirHssRfpEthChannelBW14MHz
INTEGER
}
winlink1000OduAirHssRfpIndex OBJECT-TYPE
SYNTAX INTEGER (2..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ODU RFP Table index. The index represent the Radio Frame Pattern:
typeA(2), typeB(3), typeC(4), typeD(5),typeE(6),typeF(7)."
::= { winlink1000OduAirHssRfpEntry 1 }
winlink1000OduAirHssRfpEthChannelBW5MHz OBJECT-TYPE
SYNTAX INTEGER {
bestFit(1),
nonOptimal(2),
notAvailable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Represents the compatibility of Ethernet service under Channel BW of 5MHz
in the specific Radio Frame Pattern."
::= { winlink1000OduAirHssRfpEntry 2 }
winlink1000OduAirHssRfpTdmChannelBW5MHz OBJECT-TYPE
SYNTAX INTEGER {
bestFit(1),
nonOptimal(2),
notAvailable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Represents the compatibility of TDM service under Channel BW of 5MHz
in the specific Radio Frame Pattern."
::= { winlink1000OduAirHssRfpEntry 3 }
winlink1000OduAirHssRfpEthChannelBW10MHz OBJECT-TYPE
SYNTAX INTEGER {
bestFit(1),
nonOptimal(2),
notAvailable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Represents the compatibility of Ethernet service under Channel BW of 10MHz
in the specific Radio Frame Pattern."
::= { winlink1000OduAirHssRfpEntry 4 }
winlink1000OduAirHssRfpTdmChannelBW10MHz OBJECT-TYPE
SYNTAX INTEGER {
bestFit(1),
nonOptimal(2),
notAvailable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Represents the compatibility of TDM service under Channel BW of 10MHz
in the specific Radio Frame Pattern."
::= { winlink1000OduAirHssRfpEntry 5 }
winlink1000OduAirHssRfpEthChannelBW20MHz OBJECT-TYPE
SYNTAX INTEGER {
bestFit(1),
nonOptimal(2),
notAvailable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Represents the compatibility of Ethernet service under Channel BW of 20MHz
in the specific Radio Frame Pattern."
::= { winlink1000OduAirHssRfpEntry 6 }
winlink1000OduAirHssRfpTdmChannelBW20MHz OBJECT-TYPE
SYNTAX INTEGER {
bestFit(1),
nonOptimal(2),
notAvailable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Represents the compatibility of TDM service under Channel BW of 20MHz
in the specific Radio Frame Pattern."
::= { winlink1000OduAirHssRfpEntry 7 }
winlink1000OduAirHssRfpEthChannelBW40MHz OBJECT-TYPE
SYNTAX INTEGER {
bestFit(1),
nonOptimal(2),
notAvailable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Represents the compatibility of Ethernet service under Channel BW of 40MHz
in the specific Radio Frame Pattern."
::= { winlink1000OduAirHssRfpEntry 8 }
winlink1000OduAirHssRfpTdmChannelBW40MHz OBJECT-TYPE
SYNTAX INTEGER {
bestFit(1),
nonOptimal(2),
notAvailable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Represents the compatibility of TDM service under Channel BW of 40MHz
in the specific Radio Frame Pattern."
::= { winlink1000OduAirHssRfpEntry 9 }
winlink1000OduAirHssRfpEthChannelBW80MHz OBJECT-TYPE
SYNTAX INTEGER {
bestFit(1),
nonOptimal(2),
notAvailable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Represents the compatibility of Ethernet service under Channel BW of 80MHz
in the specific Radio Frame Pattern."
::= { winlink1000OduAirHssRfpEntry 10 }
winlink1000OduAirHssRfpEthChannelBW7MHz OBJECT-TYPE
SYNTAX INTEGER {
bestFit(1),
nonOptimal(2),
notAvailable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Represents the compatibility of Ethernet service under Channel BW of 7MHz
in the specific Radio Frame Pattern."
::= { winlink1000OduAirHssRfpEntry 11 }
winlink1000OduAirHssRfpEthChannelBW14MHz OBJECT-TYPE
SYNTAX INTEGER {
bestFit(1),
nonOptimal(2),
notAvailable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Represents the compatibility of Ethernet service under Channel BW of 14MHz
in the specific Radio Frame Pattern."
::= { winlink1000OduAirHssRfpEntry 12 }
winlink1000OduAirHssRfpStr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hub Site Synchronization supported patterns"
::= { winlink1000OduAirHss 8 }
winlink1000OduAirHssHsmID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique ID which is common to the HSM and all its collocated ODUs"
::= { winlink1000OduAirHss 9 }
winlink1000OduAirHssTime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hub Site Synchronization GPS time"
::= { winlink1000OduAirHss 10 }
winlink1000OduAirHssLatitude OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hub Site Synchronization GPS Latitude"
::= { winlink1000OduAirHss 11 }
winlink1000OduAirHssNSIndicator OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hub Site Synchronization GPS N/S Indicator"
::= { winlink1000OduAirHss 12 }
winlink1000OduAirHssLongitude OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hub Site Synchronization GPS Longitude"
::= { winlink1000OduAirHss 13 }
winlink1000OduAirHssEWIndicator OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hub Site Synchronization GPS E/W Indicator"
::= { winlink1000OduAirHss 14 }
winlink1000OduAirHssNumSatellites OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hub Site Synchronization GPS Number of satellites"
::= { winlink1000OduAirHss 15 }
winlink1000OduAirHssAltitude OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hub Site Synchronization GPS Altitude"
::= { winlink1000OduAirHss 16 }
winlink1000OduAirHssRfpPhase OBJECT-TYPE
SYNTAX INTEGER {
rfpNormalPhase(1),
rfpShiftedPhase(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hub Site Synchronization GPS RFP phase"
::= { winlink1000OduAirHss 17 }
winlink1000OduAirHssInterSiteSynchronizationMode OBJECT-TYPE
SYNTAX INTEGER {
independent(1),
synchronized(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Inter-Site Synchronization Mode - independent / synchronized"
::= { winlink1000OduAirHss 18 }
winlink1000OduAirHssInterSiteSynchronizationAvailability OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(1),
available(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Inter-Site Synchronization Availability"
::= { winlink1000OduAirHss 19 }
winlink1000OduAirHssSatellitesSatSyncRequired OBJECT-TYPE
SYNTAX INTEGER {
notRequired(1),
required(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Satellites Synchronization Is Required"
::= { winlink1000OduAirHss 20 }
winlink1000OduAirHssDomainID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"EHSS domain. Indentify set of CUs with same HSS synchronization"
::= { winlink1000OduAirHss 21 }
winlink1000OduAirHssSupportedSynchronizationProtocol OBJECT-TYPE
SYNTAX INTEGER {
serialOnly(1),
ethOnly(2),
both(3),
ghssAndEth(4),
ghssEthSerial(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Supported Synchronization Protocols"
::= { winlink1000OduAirHss 22 }
winlink1000OduAirHssDesiredSynchronizationProtocol OBJECT-TYPE
SYNTAX INTEGER {
serialOnly(1),
ethOnly(2),
both(3),
ghssOnly(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Desired Synchronization Protocols"
::= { winlink1000OduAirHss 23 }
winlink1000OduAirHssDiscover OBJECT-TYPE
SYNTAX INTEGER {
startAll(1),
startAllMstr(2),
startMyDmn(3),
startMyMstr(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Initiate Discovery process of ODUs on the network."
::= { winlink1000OduAirHss 24 }
winlink1000OduAirHssNumberOfDiscoveredODUs OBJECT-TYPE
SYNTAX INTEGER (0..1000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number OF Discovered ODUs in network."
::= { winlink1000OduAirHss 25 }
-- ###########################################################
-- HSS Discover Table
-- ###########################################################
winlink1000OduAirHssDiscoverTable OBJECT-TYPE
SYNTAX SEQUENCE OF Winlink1000OduAirHssDiscoverEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"HSS Discover Table."
::= { winlink1000OduAirHss 26 }
winlink1000OduAirHssDiscoverEntry OBJECT-TYPE
SYNTAX Winlink1000OduAirHssDiscoverEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ODU Discover Table entry."
INDEX { winlink1000OduAirHssDiscoverIndex }
::= { winlink1000OduAirHssDiscoverTable 1 }
Winlink1000OduAirHssDiscoverEntry ::= SEQUENCE {
winlink1000OduAirHssDiscoverIndex
INTEGER,
winlink1000OduAirHssDiscoverODUDescription
DisplayString
}
winlink1000OduAirHssDiscoverIndex OBJECT-TYPE
SYNTAX INTEGER (1..256)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"HSS Discover Table Index."
::= { winlink1000OduAirHssDiscoverEntry 1 }
winlink1000OduAirHssDiscoverODUDescription OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hold ODU HSS status in compress format:
Domain,IP,HSS Role,Hss support,
Enabled HSS protocol,Sync Status,
Location, IPv6."
::= { winlink1000OduAirHssDiscoverEntry 2 }
-- ###################### End of Discover Table ###################
winlink1000OduAirHssMasterSlaveCompatibility OBJECT-TYPE
SYNTAX INTEGER {
compatible(1),
notCompatible(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"EHSM version compatibility. Relevant to Ethernet HSS Clients only."
::= { winlink1000OduAirHss 27 }
winlink1000OduAirHssNumberOfAssociatedCU OBJECT-TYPE
SYNTAX INTEGER (0..256)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of associated Ethernet HSS Clients. Relevant to Ethernet HSS Masters only"
::= { winlink1000OduAirHss 28 }
-- ###########################################################
-- HSS Associated CU Table
-- ###########################################################
winlink1000OduAirHssAssociatedCUTable OBJECT-TYPE
SYNTAX SEQUENCE OF Winlink1000OduAirHssAssociatedCUTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Associated Ethernet HSS Clients Table. Releant for Ethernet HSS Masters only."
::= { winlink1000OduAirHss 29 }
winlink1000OduAirHssAssociatedCUTableEntry OBJECT-TYPE
SYNTAX Winlink1000OduAirHssAssociatedCUTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Associated Ethernet HSS Clients Table Entry. Releant for Ethernet HSS Masters only."
INDEX { winlink1000OduAirHssAssociatedCUIndex }
::= { winlink1000OduAirHssAssociatedCUTable 1 }
Winlink1000OduAirHssAssociatedCUTableEntry ::= SEQUENCE {
winlink1000OduAirHssAssociatedCUIndex
INTEGER,
winlink1000OduAirHssAssociatedCUDescription
DisplayString
}
winlink1000OduAirHssAssociatedCUIndex OBJECT-TYPE
SYNTAX INTEGER (1..256)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Associated Ethernet HSS Clients Table Index. Releant for Ethernet HSS Masters only."
::= { winlink1000OduAirHssAssociatedCUTableEntry 1 }
winlink1000OduAirHssAssociatedCUDescription OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Holds Associated Ethernet HSS Clients Description in compress format:
IP,Delay,Compatibility,Ethernet Speed, Ethernet Rx rate, IPv6"
::= { winlink1000OduAirHssAssociatedCUTableEntry 2 }
-- ###################### End of Associated CU Table ###################
winlink1000OduAirHssSyncStatusEth OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
notSynchronized(2),
goodSynchronizationLevel(3),
mediumSynchronizationLevel(4),
badSynchronizationLevel(5),
startSynchronization(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet HSS Client Synchronization Level"
::= { winlink1000OduAirHss 30 }
winlink1000OduAirHssEthVLANTag OBJECT-TYPE
SYNTAX INTEGER (1..40947)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ethernet HSS VLan Tag:
The least significate decimal digit is the VLan Priority(0-6)
and the rest of the digits represents VLan ID (2-4094)"
::= { winlink1000OduAirHss 31 }
winlink1000OduAirHssHSMIPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"HSMs IP address. Relevant for HSC synchronized over Ethernet."
::= { winlink1000OduAirHss 32 }
winlink1000OduAirHssDelayToHSM OBJECT-TYPE
SYNTAX INTEGER (0..1000000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Delay in microseconds to HSM. Relevant for HSC synchronized over Ethernet."
::= { winlink1000OduAirHss 33 }
winlink1000OduAirHssSyncAcquisitionSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Accumulated quantity of seconds in clock acquisition while connected to current HSM"
::= { winlink1000OduAirHss 34 }
winlink1000OduAirHssHSMIPv6Address OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"HSMs IPv6 address. Relevant for HSC synchronized over Ethernet."
::= { winlink1000OduAirHss 35 }
-- ###################### End of HSS Section ###################
winlink1000OduAirLockRemote OBJECT-TYPE
SYNTAX INTEGER {
unlock(1),
lock(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter enables locking the link with a specific ODU.
The following values can be set:
Unlock (default) - The ODU is not locked on a specific remote ODU. Unlock can only be performed when the link is not connected.
Lock - The ODU is locked on a specific remote ODU. Lock can only be performed when the link is active."
::= { winlink1000OduAir 41 }
winlink1000OduAirAntennaGain OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Current Antenna Gain in 0.1 dBi resolution. User defined value for
external antenna.
Legal range: MinAntennaGain - Alarm.
"
::= { winlink1000OduAir 42 }
externalAlarmInPort1Alarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
The trap is sent every time an alarm occurs in the External Alarm Input of port #1.
Contains a single parameter, which is its description:
1 - Description: External Alarm 1 - - Alarm.
"
::= 105
externalAlarmInPort2Alarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
The trap is sent every time an alarm occurs in the External Alarm Input of port #2.
Contains a single parameter, which is its description:
1 - Description: External Alarm 2 - - Alarm.
"
::= 106
bitFailedAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { critical }
--&MESG "$'1"
DESCRIPTION
"
The trap is sent if there is no way to recover from the situation.
Contains two parameters:
1 - Description: ODU power up built in test failed. Error code is: %n
2 - %n number
"
::= 107
wrongConfigurationLoadedAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
The trap is sent if there is a way to recover from the situation.
Contains two parameters:
1 - Description: Wrong configuration loaded. Error code is: %n
2 - %n number
"
::= 108
lanPort1DisconnectedAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates the LAN port 1 status changed to disconnected.
Contains a single parameter, which is its description:
1 - Description: LAN port 1 status changed to disconnected.
"
::= 109
lanPort2DisconnectedAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates the LAN port 2 status changed to disconnected.
Contains a single parameter, which is its description:
1 - Description: LAN port 2 status changed to disconnected.
"
::= 110
mngPortDisconnectedAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates the LAN1 port status changed to disconnected.
Contains a single parameter, which is its description:
1 - Description: LAN1 port status changed to disconnected.
"
::= 111
externalAlarmInPort3Alarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
The trap is sent every time an alarm occurs in the External Alarm Input of port #3.
Contains a single parameter, which is its description:
1 - Description: External Alarm 3 - - Alarm.
"
::= 112
externalAlarmInPort4Alarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
The trap is sent every time an alarm occurs in the External Alarm Input of port #4.
Contains a single parameter, which is its description:
1 - Description: External Alarm 4 - - Alarm.
"
::= 113
swVersionsMismatchFullCompatibilityAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { warning }
--&MESG "$'1"
DESCRIPTION
"
The trap is sent if SW versions mismatch with full link functionality.
Contains a single parameter, which is its description:
1 - Description: Software versions mismatch - full link functionality
"
::= 114
swVersionsMismatchRestrictedCompatibilityAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { minor }
--&MESG "$'1"
DESCRIPTION
"
The trap is sent if SW versions mismatch with restricted link functionality.
Contains a single parameter, which is its description:
1 - Description: Software versions mismatch - restricted link functionality
"
::= 115
swVersionsMismatchSoftwareUpgradeRequired TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
The trap is sent if SW versions mismatch and SW upgrade is required.
Contains a single parameter, which is its description:
1 - Description: Software versions mismatch - Software upgrade required
"
::= 116
swVersionsIncompatible TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { critical }
--&MESG "$'1"
DESCRIPTION
"
The trap is sent if SW versions are incompatible.
Contains a single parameter, which is its description:
1 - Description: SW Versions incompatible
"
::= 117
hssMultipleSourcesDetectedAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates that multiple sync pulse sources were detected.
Contains a single parameter, which is its description:
1 - Description: HSS multiple sync sources were detected.
"
::= 118
hssSyncToProperSourceStoppedAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates that synchronization to a proper sync pulse source was stopped.
Contains a single parameter, which is its description:
1 - Description: HSS sync pulse - Down. The reason is: %s.
%s - Is the reason for the sync down.
"
::= 119
hssSyncPulseDetectedAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates that HSS additional sync pulse was detected.
Contains a single parameter, which is its description:
1 - Description: HSS additional sync pulse was detected.
"
::= 120
tdmBackupAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates that the TDM backup link was activated.
Contains a single parameter, which is its description:
1 - Description: TDM backup alarm - backup link was activated.
"
::= 121
linkLockUnauthorizedRemoteODU TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates that the remote ODU is unauthorized.
Contains a single parameter, which is its description:
1 - Description: Unauthorized remote ODU connection rejected.
"
::= 122
linkLockUnauthorizedODU TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates that the ODU is unauthorized.
Contains a single parameter, which is its description:
1 - Description: Unauthorized ODU connection rejected.
"
::= 123
hotStandbyAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates that the hot standby secondary link was activated.
Contains a single parameter, which is its description:
1 - Description: Secondary Link Is Active.
"
::= 124
sfpInsertion TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
Indicates that a device was inserted to SFP Port
"
::= 126
sfpPort1DisconnectedAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates the SFP port 1 status changed to disconnected.
Contains a single parameter which is its description:
1 - Description: SFP port 1 status changed to disconnected.
"
::= 127
ringRplStateActiveAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
RPL state changed to Active.
"
::= 128
desiredRatioCanNotBeAppliedAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { minor }
--&MESG "$'1"
DESCRIPTION
"
Indicates Desired UL/DL RAtio Can Not Be Applied.
"
::= 129
cbwMismatch TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates that a Channel Bandwidth mismatch was detected.
Contains two parameters:
1 - Description: Channel Bandwidth Mismatch: one side is %n0 MHz and the other is %n1 MHz.
%n0 is the local Channel Bandwidth value in MHz.
%n1 is the remoet Channel Bandwidth value in MHz."
::= 130
gpsNotSynchronized TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates that the GPS is not synchronized with satellites.
Pulses are self generated.
"
::= 131
pdTooHighDueCbwLimitations TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates that link cannot be established because
link range is too large for channel bandwidth.
"
::= 132
hbsEncryptionAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates an encryption key mismatch.
Contains a single parameter, which is its description, including the HSU's name
"
::= 133
hbsEhServiceClosedToHsu TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates an encryption key mismatch.
Contains a single parameter, which is its description, including the HSU's name
"
::= 134
hbsUnsynchronizedHsuAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { critical }
--&MESG "$'1"
DESCRIPTION
"
Indicates a registered HSU lost synchronization.
"
::= 135
hbsInactiveHbsAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates HBS is InActive.
"
::= 136
incompatibleHsu TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { critical }
--&MESG "$'1"
DESCRIPTION
"
Indicates that the HSU is not compatible to HBS.
Contains a single parameter, which is its description:
1 - Description: Incompatible ODUs.
"
::= 137
hsuUnsupportedBeacon TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { warning }
--&MESG "$'1"
DESCRIPTION
"
Indicates an unsupported beacon has arrived at HSU
"
::= 138
lanPortDisconnectedAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates the LAN port status changed to disconnected.
Contains a single parameter, which is its description:
1 - Description: LAN port status changed to disconnected.
"
::= 139
poePortDisconnectedAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates the LAN2 port status changed to disconnected.
Contains a single parameter, which is its description:
1 - Description: LAN2 port status changed to disconnected.
"
::= 140
poePowerConsumptionAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates the POE Power Consumption is above allowed maximum.
Contains a single parameter, which is its description:
1 - Description: POE consumption above allowed maximum. port closed.
"
::= 141
hobupFaultyStateAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
This Alarm will indicate that the Hot Backup module is in faulty state.
1 - Description: Hot Backup fault detected: %s unit.
%s - Primary Or Secondary Unit
"
::= 149
gpsOverCurrentAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates the GPS Antenna current consumption is above allowed maximum.
Contains a single parameter, which is its description:
1 - Description: GPS Antenna current consumption above allowed maximum. GPS closed.
"
::= 150
gpsCommunicationFailiureAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates the GPS data isn't received.
Contains a single parameter, which is its description:
1 - Description: GPS Communication failiure.
"
::= 151
temperatureThresholdAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Indicates the board temperature is above allowed maximum.
Contains a single parameter, which is its description:
1 - Description: GPS Antenna current consumption above allowed maximum. GPS closed.
"
::= 152
localRouterDiscoveryStatus TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
This Alarm will indicate that we have no connection with local train router.
1 - Description: MacLearningUpdate detected disconnection with local train router %s
%s - local train IP
"
::= 153
trackRouterDiscoveryStatus TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
This Alarm will indicate that we have no connection with Track side router.
1 - Description: MacLearningUpdate detected disconnection with Track side router %s
%s - Default gateway IP
"
::= 154
lastUserSnmpAccessOverHourAgo TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
This trap will indicate that the last access of the accessing user was more than an hour ago.
1 - Description: User %s performed SNMP access after more than an hour.
%s - user name
"
::= 155
btsTargetUnreachable TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
This Alarm will indicate that we have no connection with Bts desired target.
1 - Description: TNC detected disconnection with the BTS target %s
%s - Default gateway IP
"
::= 156
tdmServiceClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 100 }
--&MESG "$'1"
DESCRIPTION
"
Indicates that TDM Service fault is cleared.
Contains a single parameter, which is its description:
1 - Description: TDM Service - Normal.
"
::= 200
ethServiceOpened TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 101 }
--&MESG "$'1"
DESCRIPTION
"
Indicates that Ethernet Service has been opened.
Contains a single parameter, which is its description:
1 - Description: Ethernet Service has been opened.
"
::= 201
encryptionClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 103 }
--&MESG "$'1"
DESCRIPTION
"
Indicates that encryption is OK.
Contains a single parameter, which is its description:
1 - Description: Encryption Status - Normal.
"
::= 203
changeLinkPasswordClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 104 }
--&MESG "$'1"
DESCRIPTION
"
Indicates that the Link Password was changed successfully.
Contains a single parameter, which is its description:
1 - Description: Link Password has been changed at/on: %s.
%s - Is the Local Site name or Remote Site name or both sides of the Link.
"
::= 204
externalAlarmInPort1Clear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 105 }
--&MESG "$'1"
DESCRIPTION
"
This Trap is sent every time an External Alarm Input fault of port # 1 is cleared.
Contains a single parameter, which is its description:
1 - Description: External Alarm 1 - - Alarm Cleared.
"
::= 205
externalAlarmInPort2Clear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 106 }
--&MESG "$'1"
DESCRIPTION
"
This Trap is sent every time an External Alarm Input fault of port # 2 is cleared.
Contains a single parameter, which is its description:
1 - Description: External Alarm 2 - - Alarm Cleared.
"
::= 206
lanPort1Clear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 109 }
--&MESG "$'1"
DESCRIPTION
"
Indicates the LAN port 1 status changed to connected.
Contains two parameters:
1 - Description: LAN port 1 status changed to connected - %s
2 - %s Is the Eth. mode (speed & duplex)
"
::= 209
lanPort2Clear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 110 }
--&MESG "$'1"
DESCRIPTION
"
Indicates the LAN port 2 status changed to connected.
Contains two parameters:
1 - Description: LAN port 2 status changed to connected - %s.
2 - %s Is the Eth. mode (speed & duplex).
"
::= 210
mngPortClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 111 }
--&MESG "$'1"
DESCRIPTION
"
Indicates the LAN1 port status changed to connected.
Contains two parameters:
1 - Description: LAN1 port status changed to connected - %s
2 - %s Is the Eth. mode (speed & duplex)
"
::= 211
externalAlarmInPort3Clear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 112 }
--&MESG "$'1"
DESCRIPTION
"
This Trap is sent every time an External Alarm Input fault of port # 3 is cleared.
Contains a single parameter, which is its description:
1 - Description: External Alarm 3 - - Alarm Cleared.
"
::= 212
externalAlarmInPort4Clear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 113 }
--&MESG "$'1"
DESCRIPTION
"
This Trap is sent every time an External Alarm Input fault of port # 4 is cleared.
Contains a single parameter, which is its description:
1 - Description: External Alarm 4 - - Alarm Cleared.
"
::= 213
swVersionsMatchFullCompatibilityClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 114 }
--&MESG "$'1"
DESCRIPTION
"
The trap is sent if SW versions match.
Contains a single parameter, which is its description:
1 - Description: Software Versions compatible
"
::= 214
swVersionsMatchRestrictedCompatibilityClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 115 }
--&MESG "$'1"
DESCRIPTION
"
The trap is sent if SW versions match and link functionality is not restricted.
Contains a single parameter, which is its description:
1 - Description: Software Versions compatible
"
::= 215
swVersionsMatchSoftwareUpgradeRequiredClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 116 }
--&MESG "$'1"
DESCRIPTION
"
The trap is sent if SW versions match and SW upgrade is successful.
Contains a single parameter, which is its description:
1 - Description: Software Versions compatible
"
::= 216
swVersionsCompatibleClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 117 }
--&MESG "$'1"
DESCRIPTION
"
The trap is sent if SW versions compatible
Contains a single parameter, which is its description:
1 - Description: Software Versions compatible
"
::= 217
hssMultipleSourcesDisappearedClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 118 }
--&MESG "$'1"
DESCRIPTION
"
Indicates that multiple sync pulse sources disappeared.
Contains a single parameter, which is its description:
1 - Description: HSS multiple sync pulse sources disappeared.
"
::= 218
hssSyncToProperSourceAchievedClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 119 }
--&MESG "$'1"
DESCRIPTION
"
Indicates that synchronization to a proper Sync source was achieved.
Contains a single parameter, which is its description:
1 - Description: HSS sync pulse - Up.
"
::= 219
hssSyncPulseDisappearedClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 120 }
--&MESG "$'1"
DESCRIPTION
"
Indicates that HSS additional sync pulse disappeared.
Contains a single parameter, which is its description:
1 - Description: HSS additional sync pulse was disappeared.
"
::= 220
tdmBackupClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 121 }
--&MESG "$'1"
DESCRIPTION
"
Indicates that the TDM main link was activated.
Contains a single parameter, which is its description:
1 - Description: TDM main link was activated.
"
::= 221
linkLockAuthorizedRemoteODU TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 122 }
--&MESG "$'1"
DESCRIPTION
"
Indicates that the remote ODU is authorized.
Contains a single parameter, which is its description:
1 - Description: Authorized remote ODU connection accepted.
"
::= 222
linkLockAuthorizedODU TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 123 }
--&MESG "$'1"
DESCRIPTION
"
Indicates that the ODU is authorized.
Contains a single parameter, which is its description:
1 - Description: Authorized ODU connection permitted.
"
::= 223
linkAuthenticationDisabled TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 122 }
--&MESG "$'1"
DESCRIPTION
"
Indicates that the Link Lock is disabled.
Contains a single parameter, which is its description:
1 - Description: Link Authentication has been disabled.
"
::= 224
hotStandbyClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 124 }
--&MESG "$'1"
DESCRIPTION
"
Indicates that the Primary Link Was Activated.
Contains a single parameter, which is its description:
1 - Description: Primary Link Is Active.
"
::= 225
sfpExtraction TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
Indicates that a device was extracted from SFP Port
"
::= 226
sfpPort1Clear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 127 }
--&MESG "$'1"
DESCRIPTION
"
Indicates the SFP port 1 status changed to connected.
Contains two parameters:
1 - Description: SFP port 1 status changed to connected - %s
2 - %s Is the Eth. mode (speed & duplex)
"
::= 227
compatibleIdus TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 10 }
--&MESG "$'1"
DESCRIPTION
"
Indicates that the ODU has identified compatible Idus on both sides of the link.
"
::= 228
desiredRatioCanNotBeAppliedClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 129 }
--&MESG "$'1"
DESCRIPTION
"
Indicates Current UL/DL Ratio Is Equal To Desired Ratio.
"
::= 229
cbwMatch TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 130 }
--&MESG "$'1"
DESCRIPTION
"
Indicates that a Channel Bandwidth match was detected.
Contains a single parameter, which is its description:
1 - Channel Bandwidth value in MHz.
"
::= 230
switchCbwAndChannel TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
Indicates that the system is switching Channel Bandwidth and channel frequency.
Contains two parameters:
1 - Switching to Channel Bandwith %n0 MHz and to channel %n1 GHz.
"
::= 231
ringRplStateIdle TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 128 }
--&MESG "$'1"
DESCRIPTION
"
RPL state changed to Idle.
"
::= 232
ringEthServiceStatus TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
Indicates Ethernet service's state - blocked \ unblocked.
Contains a single parameter:
1 - Description: Ethernet's state (blocked \ unblocked)
"
::= 233
ringFirstRpmReceived TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
Ring application: in non-RPL link indicates first from a specific RPL was received.
Contains a single parameter:
1 - Description: RPM's VLAN ID
"
::= 234
ringEthernetSrviceUnblockedTO TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
Ring application: in non-RPL link Ethernet service is unblocked due to RPM timeout.
"
::= 235
gpsSynchronized TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 131 }
--&MESG "$'1"
DESCRIPTION
"
Indicates that the GPS is synchronized with satellites.
"
::= 236
hbsEncryptionClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 133 }
--&MESG "$'1"
DESCRIPTION
"
Indicates that encryption is OK.
Contains a single parameter, which is its description, including the HSU's name
"
::= 237
hbsEhServiceOpenedToHsu TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 134 }
--&MESG "$'1"
DESCRIPTION
"
Indicates that encryption is OK.
Contains a single parameter, which is its description, including the HSU's name
"
::= 238
hbsSynchronizedHsuAlarm TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 135 }
--&MESG "$'1"
DESCRIPTION
"
Indicates a registered HSU is synchronized.
"
::= 239
hbsActiveHbs TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 136 }
--&MESG "$'1"
DESCRIPTION
"
Indicates when HBS has been activated.
"
::= 240
switchCBW TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
Switching Channel Bandwidth.
"
::= 241
changeRatio TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
HBS Tx ratio has changed.
"
::= 242
lanPortClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 139 }
--&MESG "$'1"
DESCRIPTION
"
Indicates the LAN port status changed to connected.
Contains two parameters:
1 - Description: LAN port status changed to connected - %s
2 - %s Is the Eth. mode (speed & duplex)
"
::= 243
poePortClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 140 }
--&MESG "$'1"
DESCRIPTION
"
Indicates the LAN2 port status changed to connected.
Contains two parameters:
1 - Description: LAN2 port status changed to connected - %s
2 - %s Is the Eth. mode (speed & duplex)
"
::= 244
poePowerConsumptionClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 141 }
--&MESG "$'1"
DESCRIPTION
"
Indicates the POE power consumption is valid.
Contains two parameters:
1 - Description: POE consumption within limits. port is opened.
2 - %s Is the Eth. mode (speed & duplex)
"
::= 245
incompatibleHbsHsu TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
Incompatible HBS/HSU software versions - no service.
"
::= 246
mobilityLinkOff TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
Mobility - Link cannot be established due to:
1 - The HBS does not support Mobility
2 - Lack of resources in the HBS for HSU level
"
::= 247
enterLocalConnection TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
Entering Local Connection (Broadcast) Mode.
"
::= 248
hobupActiveStateFaultyClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 149 }
--&MESG "$'1"
DESCRIPTION
"
this clear alarm will indicate that the Hot Backup unit is in active state.
Contains a single parameter, which is its description:
1 - Description: Hot Backup %s unit activated.
%s - Primary Or Secondary Unit
"
::= 249
hobupStandbyState TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
This info fault will indicate that the Hot backup module has entered standby/peer_detection state
Contains a single parameter, which is its description:
1 - Description: Hot Backup in Standby state: %s unit.
%s - Primary Or Secondary Unit
"
::= 250
gpsOverCurrentClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 150 }
--&MESG "$'1"
DESCRIPTION
"
Indicates the GPS Antenna current consumption is valid.
"
::= 251
temperatureThresholdClear TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 152 }
--&MESG "$'1"
DESCRIPTION
"
Indicates the board temperature is valid.
"
::= 252
localRouterDiscoverySucceed TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 153 }
--&MESG "$'1"
DESCRIPTION
"
Indicated the we succeeded to discover train router in ip %s MAC address %s
%s Train IP
%s Train MAC Address
"
::= 253
trackRouterDiscoverySucceed TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 154 }
--&MESG "$'1"
DESCRIPTION
"
Indicated the we succeeded to discover track router in ip %s MAC address %s
%s Train IP
%s Train MAC Address
"
::= 254
qosVersion2StrictMismatch TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
CPE doesn't support strict QOS configuration.
"
::= 255
qosVersion2TtlMismatch TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
CPE doesn't support TTL configuration.
"
::= 256
btsTargetIsReachable TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 156 }
--&MESG "$'1"
DESCRIPTION
"
Indicated the we succeeded to establish connection with the Bts desired target (%s)
%s Target IP
"
::= 257
tcNotSupportedByHSU TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
CPE doesn't support TC functionality.
"
::= 258
syncEPortHOStateChange TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
Enter/leave HO state of SyncE port.
"
::= 259
syncEPortFailureStateChange TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
Enter/leave Failure state of SyncE port.
"
::= 260
btsCpeUpdateServiceFailed TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
Update service Failed
"
::= 261
btsCpeUpdateServiceSucceed TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
Update service Succeed
"
::= 262
radiusServerNoREsponse TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
No response from radius server
"
::= 263
noRadiusServerRespond TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { major }
--&MESG "$'1"
DESCRIPTION
"
Alarm indicates that no Radius server is connected
"
::= 264
radiusServerRespondedSuccessfully TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&CLEARS { 264 }
--&MESG "$'1"
DESCRIPTION
"
indicates that Radius server responded seccessfully.
"
::= 265
bsaAlignmentStarted TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
Indicate the beginning of Alignment Process
"
::= 266
bsaAlignmentFinished TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
Indicate the completion of Alignment Process
"
::= 267
bsaAlignmentTriggered TRAP-TYPE
ENTERPRISE winlink1000
VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex,
winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId }
--&ACTIONS { normal }
--&MESG "$'1"
DESCRIPTION
"
Indicate the triggering of Alignment Process due to exceeding thresholds
"
::= 268
-- ###########################################################
-- Products Section
-- ###########################################################
radwinProducts OBJECT IDENTIFIER ::= { radwin 20 }
winlink1000Family OBJECT IDENTIFIER ::= { radwinProducts 2 }
radwin2000Family OBJECT IDENTIFIER ::= { radwinProducts 3 }
gpsSynchronizerFamily OBJECT IDENTIFIER ::= { radwinProducts 4 }
radwin5000HBSFamily OBJECT IDENTIFIER ::= { radwinProducts 5 }
radwin5000HSUFamily OBJECT IDENTIFIER ::= { radwinProducts 6 }
radwin6000Family OBJECT IDENTIFIER ::= { radwinProducts 10 }
radwinWiFiAPFamily OBJECT IDENTIFIER ::= { radwinProducts 20 }
--
-- the following identifiers are assigned to ODU Products
--
odu OBJECT IDENTIFIER ::= { winlink1000Family 1 }
oduIntegratedAntenna OBJECT IDENTIFIER ::= { odu 1 }
oduExternalAntenna OBJECT IDENTIFIER ::= { odu 2 }
--
-- Suffix 3,4,5,6,7,8,9,10,11,12,13,14,15,16 in the products section
-- are reserved for backward compatibility.
--
odu2000 OBJECT IDENTIFIER ::= { radwin2000Family 1 }
odu2KIntegratedAntenna OBJECT IDENTIFIER ::= { odu2000 1 }
odu2KExternalAntenna OBJECT IDENTIFIER ::= { odu2000 2 }
oduGSU OBJECT IDENTIFIER ::= { gpsSynchronizerFamily 1 }
oduGSUExternalAntenna OBJECT IDENTIFIER ::= { oduGSU 2 }
hssSyncUnits OBJECT IDENTIFIER ::= { gpsSynchronizerFamily 2 }
hssISU OBJECT IDENTIFIER ::= { hssSyncUnits 1 }
hssGSU OBJECT IDENTIFIER ::= { hssSyncUnits 2 }
oduHBS OBJECT IDENTIFIER ::= { radwin5000HBSFamily 1 }
oduHBSIntegratedAntenna OBJECT IDENTIFIER ::= { oduHBS 1 }
oduHBSExternalAntenna OBJECT IDENTIFIER ::= { oduHBS 2 }
oduHSU OBJECT IDENTIFIER ::= { radwin5000HSUFamily 1 }
oduHSUIntegratedAntenna OBJECT IDENTIFIER ::= { oduHSU 1 }
oduHSUExternalAntenna OBJECT IDENTIFIER ::= { oduHSU 2 }
odu6000 OBJECT IDENTIFIER ::= { radwin6000Family 1 }
odu6K OBJECT IDENTIFIER ::= { odu6000 1 }
gateway6000 OBJECT IDENTIFIER ::= { radwin6000Family 2 }
gateway6K OBJECT IDENTIFIER ::= { gateway6000 1 }
odu600 OBJECT IDENTIFIER ::= { radwinWiFiAPFamily 1 }
oduWiFiAP OBJECT IDENTIFIER ::= { odu600 1 }
END