mibs/MIBS/sagemcom/EQUIPMENT-MIB

887 lines
28 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
--*******************************************************************
--* SAGEM, IONOS *
--*******************************************************************
--*******************************************************************
--
-- Filename: equip
--
-- File type: .mib
--
-- Description: SNMP source Mib file.
--
-- Contains general description and operation for
-- equipent level.
--
--
-- Version: 19 11 2002
--
-- Date(DD MM YYYY): 15 11 2002 last update for IONOS NMS
--
-- Contact: D. Mobuchon, F. Bonnevialle
--
-- History:
-- Version: Date: 04 08 98
-- Version: MIB-P0-301199 Date: 30 11 1999
-- Version: MIB-P0-05092000 Date: 05 09 2000
-- Modification de la table des managers
--
-- Name: S.LAURENT
-- Date: 25 04 2001
-- Desc: * Add 7 equipment modification counters
--
-- Name: S.LAURENT
-- Date: 14 06 2002
-- Desc: * DisplayString is imported from SNMPv2-TC instead of RFC1213
--
-- Name: F.Bonnevialle
-- Date: 15 11 2002
-- Desc: Modification for SilverCreek Compiler
--*******************************************************************
--*******************************************************************
--* Copyright (c) 2002, SAGEM , All rights reserved. *
--*******************************************************************
--*******************************************************************
-- MIB: EQUIPMENT-MIB
--*******************************************************************
EQUIPMENT-MIB DEFINITIONS ::= BEGIN
--*******************************************************************
-- IMPORTS
--*******************************************************************
IMPORTS
sagemDr FROM SAGEM-DR-MIB
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
IpAddress,Counter32 FROM SNMPv2-SMI
DisplayString FROM SNMPv2-TC;
-- TRAP-TYPE FROM RFC-1215;
--*******************************************************************
-- OBJECTS
--*******************************************************************
--*******************************************************************
equip MODULE-IDENTITY
LAST-UPDATED "0211150000Z"
ORGANIZATION "SAGEM/DR Tolbiac Centre"
CONTACT-INFO " "
DESCRIPTION
"
Modification:
Date: 15 11 2002
Description:
sagemDr replace sagem-dr
NOTIFICATION-TYPE replace TRAP-TYPE
Modification:
Date: 14 06 2002
Description: Modification of Imports
DisplayString is imported from SNMPv2-TC instead of RFC1213
Modification:
Date: 20 12 1999
Description: Modification of comments
Modification of bugs
Modification:
Date: 19 11 1999
Name: sagem-dr, SagemBoolean
Description: Definition of OID sagem-dr instead of sat
Definition of data SagemBoolean instead of Boolean
Name: communityString
Description: SIZE(0..20) replaced by SIZE (0..50)
New Object:
Date: 19 11 1999
Name: All *Manager* are new objects
Description: Manager list that recieves the traps.
Name: equipCptModif
Description: Incremental counter used to manage
the modifications on the equipment.
Name: communityAcces
Description: new names used
iONNOS-ANM-Supervisor instead of Set ...
Name: trapCommunity
Description:SIZE(0..20) replaced by SIZE (0..50)
Name: equipLoad
Description: Object is simplified to an OID
Name: equipLoadDiagnostic
Description: A string to help in case of problem
Name: transferedItemTable,transferedItem,
TransferedItem,transferedItemIndex
transferedItemType,transferedItemVersion
transferedItemComments
Description:
These object are used to manage the download
and upload of some part of the data; the data
can be a part of a program, a complete program,
or a config.
The transferedItemType is reused in equipLocalFile
Name: equipStatusV2
Description: used by IONOS ANM V2
"
REVISION "9808040000Z"
DESCRIPTION
"
Creation : this MIB module describes equipment level operation such as
date and time set, restart, reset, community and trap
management.
"
::= { sagemDr 107 }
--*******************************************************************
SagemBoolean ::= INTEGER { true(1), false(2) }
IntDateTime ::= INTEGER (0..2147483647)
Severity ::= INTEGER
{
nonAlarmed (1),
minor (2),
major (3),
critical (4),
warning (5),
invNonAlarmed (6),
invMinor(7),
invMajor(8),
invCritical(9),
invWarning(10)
}
--*******************************************************************
equipDateTime OBJECT-TYPE
SYNTAX IntDateTime
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this field is the date and time of the equipment.
It is the number of seconds since 1st January 1970."
::= { equip 1 }
equipLastModif OBJECT-TYPE
SYNTAX IntDateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time when the equipment was last modified."
::= { equip 2 }
equipWarmStart OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The equipment make a hot start if this field is set to `true'.
This operation can only be done by the iONOSANMsupervisor
or dIRECTACCESSsupervisor.
The value returns to `false' after the restart."
::= { equip 3 }
equipClearConf OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The equipment resets all its parameters, including those
stored in non-volatile media storage, if this field is set
to `true'.
This command does not apply to mib-2 parameters, like @ip,
routing table, etc ...
This operation can only be done by the iONOSANMsupervisor
or dIRECTACCESSsupervisor.
The value returns to `false' after the reset.
This operation is optionnal."
::= { equip 4 }
--*******************************************************************
-- Description:
-- Community
-- The "communityTable" is used for the habilitation.
-- It contains a sequense of "CommunityEntry"
-- The size for the habilitation table is 10 elements for ADR equipement.
-- A "CommunityEntry" is a sequence:
-- (communityIndex,communityString,communityAccess)
-- The different kind of habilitation are:
-- iONOSANMobserver,
-- iONOSANMoperator,
-- iONOSANMsupervisor,
-- dIRECTACCESSobserver,
-- dIRECTACCESSoperator,
-- dIRECTACCESSsupervisor,
-- The 4 last one are used for the "Add Drop for IP" IPA.
-- iONOSANMclientobserver,
-- iONOSANMclientoperator,
-- dIRECTACCESSclientobserver,
-- dIRECTACCESSclientoperator.
communityNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of community in equipment."
::= { equip 5 }
communityTable OBJECT-TYPE
SYNTAX SEQUENCE OF CommunityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of community in equipment."
::= { equip 6 }
communityEntry OBJECT-TYPE
SYNTAX CommunityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular community of the equipment."
INDEX { communityIndex }
::= { communityTable 1 }
CommunityEntry ::=
SEQUENCE {
communityIndex INTEGER,
communityString DisplayString,
communityAcces INTEGER
}
communityIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value which identify a particular
community."
::= { communityEntry 1 }
communityString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique textual string that can be used by a SNMP manager as
community string. It can be also used as password for other
configuration like http, not only snmp.
The table must have at least two entries associated with
the iONOSANMsupervisor access right (this entry is created by
equipement at startup with value `secret') and
dIRECTACCESSsupervisor access right (this entry is
created by equipement at startup with value 'supervisor') .
According to equipment implementation, it is possible to
create other entries associed with lower rights that PDU
community string can afford (actualy equal if
IONOSANMsupervisor status is granted).
If the other access rights are created at startup by the equipment,
its must use the following values : 'private' for
'iONOSANMoperator, 'public' for 'iONOSANMobserver',
'operator' for dIRECTACCESSoperator, 'observer' for
dIRECTACCESSobserver, and 'client' for the others.
All community string can be modified only by
IONOSANMsupervisor.
A dIRECTACCESS community string can be modified by
dIRECTACCESSsupervisor.
The reading of a community string gives *** for all
access rights .
An entry may be discarded by setting its community string to
void string. This should not be used by the administrator or
he could discard himself "
::= { communityEntry 2 }
communityAcces OBJECT-TYPE
SYNTAX INTEGER {iONOSANMobserver (1),
iONOSANMoperator(2),
iONOSANMsupervisor(3),
dIRECTACCESSobserver (4),
dIRECTACCESSoperator(5),
dIRECTACCESSsupervisor(6),
iONOSANMclientobserver(7),
iONOSANMclientoperator(8),
dIRECTACCESSclientobserver(9),
dIRECTACCESSclientoperator(10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
iONOSANMsupervisor(3) access :
allows all operations including community string
(community string = password)
iONOSANMoperator(2) access :
allows all set operations except write community
string read or write and also some special operations.
iONOSANMobserver (1) access :
allows only get and get_next requests.
dIRECTACCESSsupervisor(6) access :
allows all operations EXcluding IONOS ANM community string
dIRECTACCESSoperator(5) access :
allows all set operations except write community
string read or write and also some special operations.
dIRECTACCESSobserver (4) access :
allows only get and get_next requests.
iONOSANMclientoperator(8) access :
allows only set some special operations
iONOSANMclientobserver(7) access :
allows only get and get_next requests for special operations
dIRECTACCESSclientoperator(10) access :
allows only set some special operations
dIRECTACCESSclientobserver(9) access :
allows only get and get_next requests for special operations
"
::= { communityEntry 3 }
--*******************************************************************
-- Description:
-- "trapTable": trap's receiver table
trapNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of trap receivers description in equipment."
::= { equip 7 }
trapTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of trap receivers in equipment."
::= { equip 8 }
trapEntry OBJECT-TYPE
SYNTAX TrapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular trap of the equipment."
INDEX { trapIndex }
::= { trapTable 1 }
TrapEntry ::=
SEQUENCE {
trapIndex INTEGER,
trapDestination IpAddress,
trapCommunity DisplayString
}
trapIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value which identify a particular
trap receiver.
The value of index is a constant assigned to an entry at
equipment design time. "
::= { trapEntry 1 }
trapDestination OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ip address to which the equipment will send the traps.
Note that the value must be unique along this table.
An entry may be discarded by setting the IP address to 0.0.0.0
"
::= { trapEntry 2 }
trapCommunity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
-- It is better to use a size value lower than 10.
-- The size value 50 is used for the BMX
"The community string to use when a trap is sent to
this address. "
::= { trapEntry 3 }
--*******************************************************************
-- Description:
-- Up and download for the software and configuration
--
equipLoad OBJECT IDENTIFIER ::= { equip 9 }
equipLocalFile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The file path suitable for the equipment."
::= { equipLoad 1 }
equipServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ip adress of tftp serveur from which is read/write
the file `equipRemoteFile'."
::= { equipLoad 2 }
equipRemoteFile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The file path to be loaded on/from the equipement."
::= { equipLoad 3 }
equipDirection OBJECT-TYPE
SYNTAX INTEGER { download (0), upload(1)
, backupDownload (2), switching (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field selects the direction of data stream.
When it is set to `backupDownload', only the transfert is done.
When it is set to `download' the transfert is done and then the
information transfert is switched in the operational state.
When it is set to `switching', there is no transfert;
there is only a switching. "
::= { equipLoad 4 }
equipLoadProceed OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
This entry is use to start (set to `true') loading a file
on/from a equipment which has a tftp client.
The value of the field remains to `true' until load is
completed or has been aborted.
This operation can only be done by the iONOSANMsupervisor
or dIRECTACCESSsupervisor.
It may be possible to abort the loading by setting it
to false.
After the switching of a new configuration, the equipment
must increase the value of the variable 'equipCptModif'
"
::= { equipLoad 5 }
equipLoadDiagnostic OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A string used to help in case of trouble."
::= { equipLoad 6 }
equipLoadProtocole OBJECT-TYPE
SYNTAX INTEGER { ftp (1), tftp (2),
http (3), telnet (4)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Protocole used by the equipment for the download"
::= { equipLoad 7 }
--*******************************************************************
-- Description:
-- Delayed up and download for the software and configuration
--
-- equipLoadState OBJECT-TYPE
-- SYNTAX INTEGER { delayedLoad (1), loadRunning (2),
-- delayedSwitching (3), switchingRunning (4),
-- loadOK (5), loadNOK (6) ,aborted (7)}
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This field indicates the status of the current load processes valided
-- by 'equipLoadProceed'.
-- Remark : a download includes a data transfer (load) from the
-- server to the equipment and a switching for using the data or the
-- software transfered . A upload includes only a data transfer from
-- the equipment to the server
-- It's optional for the equipment which doesn't realise delayed download "
-- ::= { equipLoad 8 }
--
-- equipLoadDateTime OBJECT-TYPE
-- SYNTAX IntDateTime
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The value of this field is the date and time of the equipment
-- at which the load processes valided by
-- 'equipLoadProceed' must begin .
-- If this value if equal at 0 or < at the current
-- time, the load starts immediately.
-- It is the number of seconds since 1st January 1970."
-- ::= { equipLoad 9 }
--
-- equipSwitchingDateTime OBJECT-TYPE
-- SYNTAX IntDateTime
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "
-- The value of this field is the date and time of the equipment
-- at which the switching processes valided by
-- 'equipLoadProceed' must begin .If this value if equal at
-- 0 or < at the current time, the switching starts immediately
-- (if there isn't load)or immediately after the load (if there is a load).
-- It is the number of seconds since 1st January 1970.
-- After the switching of a new configuration, the equipment
-- must increase the value of the variable 'equipCptModif'
-- "
-- ::= { equipLoad 10 }
--
--*******************************************************************
-- Description:
-- These object are used to manage the download
-- and upload of some part of the data; the data
-- can be a part of a program, a complete program,
-- or a config.
--
-- The transferedItemType can be:
-- inactive programName
-- active programName
-- inactive"Config"
-- active"Config"
-- ALL Program
-- ALL
--
-- The transferedItemType is reused in equipLocalFile
transferedItemTable OBJECT-TYPE
SYNTAX SEQUENCE OF TransferedItemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of uploaded or downloaded Item from the
equipment."
::= { equip 30 }
transferedItemEntry OBJECT-TYPE
SYNTAX TransferedItemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular Item transferd from/to the equipment."
INDEX { transferedItemIndex }
::= { transferedItemTable 1 }
TransferedItemEntry ::=
SEQUENCE {
transferedItemIndex INTEGER,
transferedItemType DisplayString,
transferedItemVersion DisplayString,
transferedItemComment DisplayString
}
transferedItemIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { transferedItemEntry 1 }
transferedItemType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"used to know what kind of data to transferate,
mainly programName or config"
::= { transferedItemEntry 2 }
transferedItemVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"for a program, return the software version;
for a config return the associated software version"
::= { transferedItemEntry 3 }
transferedItemComment OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"give additional information about the tranfered data"
::= { transferedItemEntry 4 }
--*******************************************************************
-- Description:
equipStatus OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This field summerizes the status of all equipment objects
(port, card, ...)
This variable is polled by IONOS ANM V1
The 'equipmentStatusTrap' is sent after a GET on this variable.
equipStatus and equipStatusTrap are only used with V1.
"
::= { equip 10 }
equipStatusV2 OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Replace equipStatus for the v2. For the v1, equipStatus
in EQUIPMENT-MIB send a trap after been polled;
For the v2, equipStatus is polled."
::= { equip 11 }
--*******************************************************************
--* modification counters
--*******************************************************************
-- Description:
-- "equipCptModif":
-- Incremental counter used to manage the modifications
-- on the equipment.
-- Warning:
-- Replace equipLastModif for the new equipment ADR155c and
-- the next generation of equipment.
equipCptModif OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter for all equipments modifications. It represents
the sum of the 7 other counters"
::= { equip 12 }
-- Modification counters
cptModif OBJECT IDENTIFIER ::= { equip 14 }
cptSNC OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter version for the SNC modifications."
::= { cptModif 1 }
cptCnx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter version for the Connexion modifications."
::= { cptModif 2 }
cptMSP OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter version for the MSP modifications."
::= { cptModif 3 }
cptMsSpring OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter version for the MS-SPRING modifications."
::= { cptModif 4 }
cptSynchro OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter version for the Synchro modifications."
::= { cptModif 5 }
cptMngt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter version for the MNGT modifications (mngt list, password, trap, ...)."
::= { cptModif 6 }
cptNet OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter version for the Network modifications."
::= { cptModif 7 }
-- equipConfSaveStatus OBJECT-TYPE
-- SYNTAX SagemBoolean
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "If 'true', this variable indicates that all configuration
-- modifications are saved in flash memory.
-- If false, this variable indicates that configuration
-- modifications are not saved in flash memory. "
-- ::= { equip 13 }
--*******************************************************************
--
-- Description:
-- ACCESS TABLE FILTER
-- The table is a access filter table that ckeck the IP address of
-- the SNMP managers.
equipManagerNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of manager = number of IP addresses in the table"
::= { equip 20 }
equipManagerTable OBJECT-TYPE
SYNTAX SEQUENCE OF EquipManagerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table containing Ip Addresses and maximum authorized level"
::= { equip 21 }
equipManagerEntry OBJECT-TYPE
SYNTAX EquipManagerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry containing IP addresses of managers allowed in R/W."
INDEX {equipManagerIndex}
::= {equipManagerTable 1}
EquipManagerEntry ::=
SEQUENCE
{
equipManagerIndex INTEGER,
equipManagerAddress IpAddress,
equipManagerADM SagemBoolean,
equipManagerOPR SagemBoolean,
equipManagerOBS SagemBoolean
}
equipManagerIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of equipManagerTable
There's only 10 values in this table"
::= {equipManagerEntry 1}
equipManagerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of one of the allowed managers.
If the table contains only address values which are equal
to 0.0.0.0, no access filter are done.
Write the IP address 0.0.0.0 to remove a manager.
This operation can only be done by the iONOSANMsupervisor.
"
::= {equipManagerEntry 2}
equipManagerADM OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If 'true', this variable indicates that the manager defined by
its address can have the Supervisor rigth as maximum level
The value 'false' is set by the equipment when another level
is choosen"
::= {equipManagerEntry 3}
equipManagerOPR OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If 'true', this variable indicates that the manager defined by
its address can have the Operator rigth as maximum level
The value 'false' is set by the equipment when another level
is choosen"
::= {equipManagerEntry 4}
equipManagerOBS OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If 'true', this variable indicates that the manager defined by
its address can have the Observer rigth as maximum level
The value 'false' is set by the equipment when another level
is choosen"
::= {equipManagerEntry 5}
--*******************************************************************
-- Warning: This Trap is only used for V1
-- equipStatusTrap TRAP-TYPE
-- ENTERPRISE equip
-- VARIABLES { equipStatus }
-- DESCRIPTION
-- "This trap indicates the alarm status of the equipment.
-- Only sent with IONOS ANM V1"
-- ::= 1
equipTraps OBJECT IDENTIFIER ::= { equip 0 }
equipStatusTrap NOTIFICATION-TYPE
OBJECTS { equipStatus }
STATUS current
DESCRIPTION "This trap indicates the alarm status of the equipment.
Only sent with IONOS ANM V1"
REFERENCE ""
::= { equipTraps 1 }
END