mibs/MIBS/sagemcom/GIGE-MIB

991 lines
31 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
--*******************************************************************
--* SAGEM SA *
--*******************************************************************
--*******************************************************************
-- Filename: GigE
-- File type: .mib
--
-- Description: SNMPc source Mib file.
-- The MIB module defines the gigabitEthernet card managment in Adr2500c
--
-- Version: 19 11 2002
--
-- Date(DD MM YYYY): 15 11 02 last update for IONOS NMS
--
-- Contact: D. Mobuchon, F. Bonnevialle
--
-- History:
-- Name: S.LAURENT
-- Date: 22 05 2002
-- Desc: original
--
-- Name: F.Bonnevialle
-- Date: 15 11 2002
-- Desc: Modification for SilverCreek Compiler
--
--*******************************************************************
--*******************************************************************
--* Copyright (c) 2002, SAGEM , All rights reserved. *
--*******************************************************************
--*******************************************************************
-- MIB: GIGE-MIB
--*******************************************************************
GIGE-MIB DEFINITIONS ::= BEGIN
--*******************************************************************
-- IMPORTS
--*******************************************************************
IMPORTS
adr2500c FROM ADR2500C-MIB
SagemBoolean, Severity FROM EQUIPMENT-MIB
MODULE-IDENTITY,OBJECT-TYPE,Counter64 FROM SNMPv2-SMI
DisplayString, PhysAddress FROM SNMPv2-TC;
gige MODULE-IDENTITY
LAST-UPDATED "0205220000Z"
ORGANIZATION "SAGEM-Tolbiac drd/ddp/tmhd"
CONTACT-INFO
" "
DESCRIPTION
"The MIB module specific for GigE module of Adr2500c"
::= { adr2500c 10 }
--*******************************************************************
--* Gige part
--*******************************************************************
BandwidthSize ::= INTEGER
{
none(0),
stm1(1),
stm4(4),
stm16(16),
stm64(64)
}
gigeNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of gigabitEthernet cards in equipment."
::= { gige 10 }
gigeTable OBJECT-TYPE
SYNTAX SEQUENCE OF GigeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of gigabitEthernet cards in equipment."
::= { gige 11 }
gigeEntry OBJECT-TYPE
SYNTAX GigeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular gigabitEthernet card of the equipment."
INDEX { gigeIndex }
::= { gigeTable 1 }
GigeEntry ::= SEQUENCE {
gigeIndex INTEGER, -- boardIndex
gigeSdhBandwidth BandwidthSize,
gigeAutoTest SagemBoolean,
gigeWarmStart SagemBoolean
}
gigeIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value which identify a particular gigabitEthernet card of the equipment.
The value of this index is a constant value assigned to an entry at
equipment design time. It is usualy related to harware"
::= { gigeEntry 1 }
gigeSdhBandwidth OBJECT-TYPE
SYNTAX BandwidthSize
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field set the size of the SDH Bandwidth which is allocated to the gigabitEthernet card."
::= { gigeEntry 2 }
gigeAutoTest OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the value of this field is set to true, an autotest is executed on the gigabitEthernet card."
::= { gigeEntry 3 }
gigeWarmStart OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the value of this field is set to true, a warmStart is launched on the gigabitEthernet card."
::= { gigeEntry 4 }
-- End of gige description
--*******************************************************************
--* Maintenance part
--*******************************************************************
LoopbackGE ::= INTEGER
{
none(0), -- GE-SDH Bidirectionnal Transmission
local1(1), -- GE-GE Loopback (above GFP)
local2(2), -- GE-GE Loopback (beyong GFP)
local3(3), -- GE-GE Loopback (into SERDES)
local4(4), -- GE-GE Loopback (into GMAC Bloc)
remote(10) -- SDH-SDH Loopback (into Tramer)
}
maintenanceNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of gigabitEthernet ports in equipment."
::= { gige 20 }
maintenanceTable OBJECT-TYPE
SYNTAX SEQUENCE OF MaintenanceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of gigabitEthernet ports in equipment."
::= { gige 21 }
maintenanceEntry OBJECT-TYPE
SYNTAX MaintenanceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular gigabitEthernet port of the equipment."
INDEX { maintenanceIndex }
::= { maintenanceTable 1 }
MaintenanceEntry ::= SEQUENCE {
maintenanceIndex INTEGER, -- channelIndex = nspiTTPIndex
maintenanceAutoTest SagemBoolean,
maintenanceLoopback LoopbackGE,
maintenancePRBSSent DisplayString,
maintenancePRBSReceived DisplayString,
maintenanceResetAllCounters SagemBoolean,
maintenanceResetLanCounters SagemBoolean,
maintenanceResetGfpCounters SagemBoolean,
maintenanceResetQosCounters SagemBoolean
}
maintenanceIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value which identify a particular gigabitEthernet port of the equipment.
The value of this index is a constant value assigned to an entry at
equipment design time. It is usualy related to harware"
::= { maintenanceEntry 1 }
maintenanceAutoTest OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the value of this field is set to true, an autotest is executed on the gigabitEthernet port."
::= { maintenanceEntry 2 }
maintenanceLoopback OBJECT-TYPE
SYNTAX LoopbackGE
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field set a loopback mode to a particular gigabitEthernet port."
::= { maintenanceEntry 3 }
maintenancePRBSSent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field allows to sent a PRBS frame on a particular gigabitEthernet port."
::= { maintenanceEntry 4 }
maintenancePRBSReceived OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value is the actual PRBS frame received in the particular gigabitEthernet port."
::= { maintenanceEntry 5 }
maintenanceResetAllCounters OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the value of this field is set to true, all counters attached to this interface are deleted."
::= { maintenanceEntry 6 }
maintenanceResetLanCounters OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the value of this field is set to true, all QoS counters attached to this interface are deleted."
::= { maintenanceEntry 7 }
maintenanceResetGfpCounters OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the value of this field is set to true, all Gfp counters attached to this interface are deleted."
::= { maintenanceEntry 8 }
maintenanceResetQosCounters OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the value of this field is set to true, all Qos counters attached to this interface are deleted."
::= { maintenanceEntry 9 }
-- End of maintenance part
--*******************************************************************
--* QoS part
--*******************************************************************
QosType ::= INTEGER
{
none(0),
pauseMode(1),
userPriority(2),
vlanId(3),
balanced(4),
ipv4TOS(10),
ipv6TClass(11),
dscp(13)
}
CongestionControl ::= INTEGER
{
none(0),
red(1), -- Random Early Detection
wred(2) -- Weighted Random Early Detection
}
SchedulingSystem ::= INTEGER
{
unknown(0),
spq(1), -- Strict Priority Queuing
wfq(4), -- Weighted Fair Queuing
cbwfq(5), -- Class-Based Weighted Fair Queuing
wrr(10) -- Weighted Round Robbin
}
qosNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Quality of Service set in equipment. This number match to channelNumber because
there is only one Qos per Sdh Channel.
= number of entries in qosTable"
::= { gige 30 }
qosTable OBJECT-TYPE
SYNTAX SEQUENCE OF QosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of Qos in equipment."
::= { gige 31 }
qosEntry OBJECT-TYPE
SYNTAX QosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular qos of the equipment."
INDEX { qosIndex }
::= { qosTable 1 }
QosEntry ::= SEQUENCE {
qosIndex INTEGER, -- channelIndex = nspiTTPIndex
qosClassNumber INTEGER,
qosType QosType,
qosCongestionControl CongestionControl,
qosSchedulingSystem SchedulingSystem,
qosBwREnable SagemBoolean,
qosHCInCCDiscardsGe Counter64,
qosHCInCCDiscardsWan Counter64
}
qosIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value which identify a particular QoS of the equipment.
The value of this index is a constant value assigned to an entry at
equipment design time. It is usualy related to harware"
::= { qosEntry 1 }
qosClassNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field allows to choose the number of CoS defined for the QoS"
::= { qosEntry 2 }
qosType OBJECT-TYPE
SYNTAX QosType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field allows to choose the type of Qos"
::= { qosEntry 3 }
qosCongestionControl OBJECT-TYPE
SYNTAX CongestionControl
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field allows to choose a mechanism to manage congestion problems. Some Type of Qos
force the value of this field. "
::= { qosEntry 4 }
qosSchedulingSystem OBJECT-TYPE
SYNTAX SchedulingSystem
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field allows to choose a mechanism to manage congestion problems. "
::= { qosEntry 5 }
qosBwREnable OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field allows to activate or desactivate the Sdh throughput reservation feature. "
::= { qosEntry 6 }
qosHCInCCDiscardsGe OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets received on the GE interface which were discarded to prevent from switch saturation"
::= { qosEntry 7 }
qosHCInCCDiscardsWan OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets received on the WAN interface which were discarded to prevent from switch saturation"
::= { qosEntry 8 }
-- End of QoS part
--*******************************************************************
--* CoS part
--*******************************************************************
CosId ::= INTEGER
{
cos0(0),
cos1(1),
cos2(2),
cos3(3),
cos4(4),
cos5(5),
cos6(6),
cos7(7)
}
cosNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Class of Service set in equipment
= number of entries in cosTable
= qosNumber * qosClassNumber"
::= { gige 40 }
cosTable OBJECT-TYPE
SYNTAX SEQUENCE OF CosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of CoS in equipment."
::= { gige 41 }
cosEntry OBJECT-TYPE
SYNTAX CosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular CoS of the equipment."
INDEX { cosIndex }
::= { cosTable 1 }
CosEntry ::= SEQUENCE {
cosIndex INTEGER,
cosQosId INTEGER, -- qosIndex
cosId CosId,
cosDefinition DisplayString,
cosBwRRatioMin INTEGER,
cosBwRRatioMax INTEGER,
cosHCInOctets Counter64,
cosHCOutOctets Counter64,
cosHCInPkts Counter64,
cosHCOutPkts Counter64,
cosHCInCCDiscards Counter64
}
cosIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value which identify a particular CoS of the equipment.
The value of this index is a constant value assigned to an entry at
equipment design time. It is usualy related to harware. Its values are taken between 1 and cosNumber."
::= { cosEntry 1 }
cosQosId OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This field allows to identify which QoS this Class is belonging. Its values must match to qosIndex."
::= { cosEntry 2 }
cosId OBJECT-TYPE
SYNTAX CosId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" This field identify the class of Service."
::= { cosEntry 3 }
cosDefinition OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This optional textual field brings some precisions about the CoS configuration. "
::= { cosEntry 4 }
cosBwRRatioMin OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the qosBwREnable field is set to True, then this field allows to configure the guaranted percentage of SDH
throughput which must be booked up for the CoS"
::= { cosEntry 5 }
cosBwRRatioMax OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the qosBwREnable field is set to True, then this field allows to configure the maximum percentage of SDH
throughput which can be booked up for the CoS"
::= { cosEntry 6 }
cosHCInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets received on the GE interface (excluding framing characters preambule and sfd)
and belonging to a CosId packet"
::= { cosEntry 7 }
cosHCOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets transmitted out of the Wan interface (excluding framing characters preambule and sfd)
and belonging to a CosId paket"
::= { cosEntry 8 }
cosHCInPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets received on the GE interface (excluding framing characters preambule and sfd)
and belonging to a CosId packet"
::= { cosEntry 9 }
cosHCOutPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets transmitted out of the Wan interface (excluding framing characters preambule and sfd)
and belonging to a CosId paket"
::= { cosEntry 10 }
cosHCInCCDiscards OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of CosId packets received on the GE interface which were discarded by RED/WRED/BandWidthReservation
to prevent from congestion."
::= { cosEntry 11 }
-- End of CoS part
--*******************************************************************
--* GFP part
--*******************************************************************
GfpFailure ::= INTEGER
{
none(0),
oofd(1),
lofd(2),
fdsc(3)
}
GfpState ::= INTEGER(0..2147483647)
-- {
-- none(0),
-- (1),
-- (2),
-- (3)
-- }
gfpNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ports Number of the Gfp layer.
= number of entries in gfpTable "
::= { gige 50 }
gfpTable OBJECT-TYPE
SYNTAX SEQUENCE OF GfpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of gfp port in the equipment."
::= { gige 51 }
gfpEntry OBJECT-TYPE
SYNTAX GfpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular gfp port of the equipment."
INDEX { gfpIndex }
::= { gfpTable 1 }
GfpEntry ::= SEQUENCE {
gfpIndex INTEGER, -- channelIndex
gfpHCInPkts Counter64,
gfpHCInIdlePkts Counter64,
gfpHCInCorruptedPkts Counter64,
gfpHCInErrors Counter64,
gfpHCInCorrectedPkts Counter64,
gfpHCFCSErrors Counter64,
gfpHCInOctets Counter64,
gfpHCOutPkts Counter64,
gfpHCOutIdlePkts Counter64,
gfpHCOutOctets Counter64,
gfpIdleRate INTEGER,
gfpSendingRate INTEGER,
gfpState GfpState,
gfpAdminStatus INTEGER,
gfpOperStatus INTEGER,
gfpMonitor SagemBoolean,
gfpFailure GfpFailure,
gfpSeverity Severity,
gfpOOFD Severity,
gfpLOFD Severity,
gfpFDSC Severity
}
gfpIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value which identify a particular gfp port in the equipment.
The value of this index is a constant value assigned to an entry at
equipment design time. It is usualy related to harware. Its values are mapped to channelIndex values."
::= { gfpEntry 1 }
gfpHCInPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The total number of packets received on the Gfp interface"
::= { gfpEntry 2 }
gfpHCInIdlePkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The total number of Idle frames received on the Gfp interface"
::= { gfpEntry 3 }
gfpHCInCorruptedPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The total number of mismatched packets received on the Gfp interface."
::= { gfpEntry 4 }
gfpHCInErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of mismatched packets that have been discarded. "
::= { gfpEntry 5 }
gfpHCInCorrectedPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of mismatched packets received on the Gfp interface that have been corrected. "
::= { gfpEntry 6 }
gfpHCFCSErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received on the Gfp interface that are an integral number of octets
in length but do not pass the FCS check. "
::= { gfpEntry 7 }
gfpHCInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The total number of Octets received on the Gfp interface"
::= { gfpEntry 8 }
gfpHCOutPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The total number of packets transmitted out of the Gfp interface"
::= { gfpEntry 9 }
gfpHCOutIdlePkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The total number of Idle frame transmitted out of the Gfp interface"
::= { gfpEntry 10 }
gfpHCOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The total number of packets transmitted out of the Gfp interface"
::= { gfpEntry 11 }
gfpIdleRate OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The received Idle frames rate on a particular gfp port. "
::= { gfpEntry 12 }
gfpSendingRate OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The sent frames rate on a particular gfp port. "
::= { gfpEntry 13 }
gfpState OBJECT-TYPE
SYNTAX GfpState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This field allows to know in which state this gfp port is working."
::= { gfpEntry 14 }
gfpAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1), -- ready to pass packets
down(2),
testing(3) -- in some test mode
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The desired state of the gfp port. The
testing(3) state indicates that no operational
packets can be passed."
::= { gfpEntry 15 }
gfpOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1), -- ready to pass packets
down(2),
testing(3) -- in some test mode
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational state of the gfp port.
The testing(3) state indicates that no operational
packets can be passed."
::= { gfpEntry 16 }
gfpMonitor OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the value of this field is set to false, the failure detection
is stopped for this gfp port."
::= { gfpEntry 17 }
gfpFailure OBJECT-TYPE
SYNTAX GfpFailure
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active failures on channel"
::= { gfpEntry 18 }
gfpSeverity OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to failure severity for gfp port."
::= { gfpEntry 19 }
gfpOOFD OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Severity associated with Out of Frame Delineation failure
for gfp port."
::= { gfpEntry 20 }
gfpLOFD OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Severity associated with Loss Of Frame Delineation failure
for gfp port."
::= { gfpEntry 21 }
gfpFDSC OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Severity associated with Frame Delineation State Change failure
for gfp port."
::= { gfpEntry 22 }
-- End of GFP part
--*******************************************************************
--* PAUSE part
--*******************************************************************
PauseFailure ::= INTEGER
{
none(0),
pauseModeRejected(1)
}
pauseNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of ports in the equipment which accept Pause mechanism
= number of entries in pauseTable "
::= { gige 60 }
pauseTable OBJECT-TYPE
SYNTAX SEQUENCE OF PauseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of Ethernet port in the equipment which accept Pause mechanism."
::= { gige 61 }
pauseEntry OBJECT-TYPE
SYNTAX PauseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular Ethernet port of the equipment."
INDEX { pauseIndex }
::= { pauseTable 1 }
PauseEntry ::= SEQUENCE {
pauseIndex INTEGER, -- Lan ifIndex
pauseTime INTEGER,
pauseBetweenTime INTEGER,
pauseMacSA PhysAddress,
pauseMacDA PhysAddress,
pauseCHT INTEGER,
pauseCLT INTEGER,
pauseMonitor SagemBoolean,
pauseFailure PauseFailure,
pauseSeverity Severity,
pauseModeRejected Severity
}
pauseIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value which identify a particular Ethernet Physical port of a gigabitEthernet card.
The value of this index is a constant value assigned to an entry at
equipment design time. It is usualy related to harware. Its values are mapped to IfIndex values of Lan Ports."
::= { pauseEntry 1 }
pauseTime OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field allows to set the Time during which the linkPartner stop any transmission. The Unit used is the time slot
(= 512 ns)."
::= { pauseEntry 2 }
pauseBetweenTime OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field allows to set the Time between two Pause Frames transmission. The Unit used is the time slot
(= 512 ns)."
::= { pauseEntry 3 }
pauseMacSA OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The physical address of the Ethernet port.
This address is used to fill the SourceAddress field of any Pause Frame which is trasmitted by the LinkPartner."
::= { pauseEntry 4 }
pauseMacDA OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The physical address used to fill the DestinationAddress field of any Pause Frame which is transmitted by the LinkPartner."
::= { pauseEntry 5 }
pauseCHT OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field allows to configure the credit High Threshold of Pause mechanism."
::= { pauseEntry 6 }
pauseCLT OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field allows to configure the credit Low Threshold of Pause mechanism."
::= { pauseEntry 7 }
pauseMonitor OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the value of this field is set to false, the failure detection
is stopped for this Ethernet port."
::= { pauseEntry 10 }
pauseFailure OBJECT-TYPE
SYNTAX PauseFailure
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active failures in the pause mechanism of the Ethernet port."
::= { pauseEntry 11 }
pauseSeverity OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to severity associated to the current pause failure."
::= { pauseEntry 12 }
pauseModeRejected OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field allows to configure the Severity associated with Pause Mode Rejected failure
for Ethernet port."
::= { pauseEntry 13 }
-- End of Pause part
END