991 lines
		
	
	
		
			31 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			991 lines
		
	
	
		
			31 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
--*******************************************************************
 | 
						|
--*    SAGEM SA			 							  				*
 | 
						|
--*******************************************************************
 | 
						|
--*******************************************************************
 | 
						|
 | 
						|
--  Filename: GigE
 | 
						|
--  File type: .mib    
 | 
						|
-- 
 | 
						|
--  Description:	SNMPc source Mib file.
 | 
						|
--		The MIB module defines the gigabitEthernet card managment in Adr2500c
 | 
						|
--
 | 
						|
--  Version:  19 11 2002
 | 
						|
--	
 | 
						|
--  Date(DD MM YYYY): 15 11 02 last update for IONOS NMS 
 | 
						|
--     
 | 
						|
--  Contact: D. Mobuchon, F. Bonnevialle
 | 
						|
--
 | 
						|
--  History: 
 | 
						|
--		Name: S.LAURENT	
 | 
						|
--		Date: 22 05 2002 
 | 
						|
--		Desc: original
 | 
						|
--   
 | 
						|
--		Name: F.Bonnevialle 	
 | 
						|
--		Date: 15 11 2002 		
 | 
						|
--		Desc: Modification for SilverCreek Compiler
 | 
						|
--
 | 
						|
--*******************************************************************
 | 
						|
--*******************************************************************
 | 
						|
--*   Copyright (c) 2002, SAGEM , All rights reserved.              *
 | 
						|
--*******************************************************************
 | 
						|
 | 
						|
 | 
						|
 | 
						|
 | 
						|
--*******************************************************************
 | 
						|
-- MIB: GIGE-MIB
 | 
						|
--*******************************************************************
 | 
						|
GIGE-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
--*******************************************************************
 | 
						|
-- IMPORTS
 | 
						|
--*******************************************************************
 | 
						|
   IMPORTS
 | 
						|
   adr2500c								FROM ADR2500C-MIB 
 | 
						|
   SagemBoolean, Severity						FROM EQUIPMENT-MIB
 | 
						|
   MODULE-IDENTITY,OBJECT-TYPE,Counter64				FROM SNMPv2-SMI
 | 
						|
   DisplayString, PhysAddress              				FROM SNMPv2-TC; 
 | 
						|
 | 
						|
   gige	MODULE-IDENTITY
 | 
						|
      LAST-UPDATED "0205220000Z"
 | 
						|
      ORGANIZATION "SAGEM-Tolbiac drd/ddp/tmhd"
 | 
						|
      CONTACT-INFO
 | 
						|
	"    "
 | 
						|
      DESCRIPTION 
 | 
						|
        "The MIB module specific for GigE module of Adr2500c"
 | 
						|
      ::= { adr2500c 10 }
 | 
						|
                                                                      
 | 
						|
                                                                      
 | 
						|
--*******************************************************************
 | 
						|
--* Gige part  
 | 
						|
--*******************************************************************   
 | 
						|
 | 
						|
   BandwidthSize    ::= INTEGER 
 | 
						|
   { 
 | 
						|
   	none(0), 
 | 
						|
   	stm1(1), 
 | 
						|
   	stm4(4), 
 | 
						|
   	stm16(16),
 | 
						|
   	stm64(64)
 | 
						|
   }
 | 
						|
      
 | 
						|
   gigeNumber   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"Number of gigabitEthernet cards in equipment."  
 | 
						|
      ::= { gige 10 } 
 | 
						|
   
 | 
						|
   gigeTable   OBJECT-TYPE
 | 
						|
      SYNTAX       SEQUENCE OF GigeEntry
 | 
						|
      MAX-ACCESS   not-accessible
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"List of gigabitEthernet cards in equipment."  
 | 
						|
      ::= { gige 11 } 
 | 
						|
   
 | 
						|
   gigeEntry   OBJECT-TYPE
 | 
						|
      SYNTAX       GigeEntry
 | 
						|
      MAX-ACCESS   not-accessible
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"A particular gigabitEthernet card of the equipment." 
 | 
						|
      INDEX        { gigeIndex  } 
 | 
						|
      ::= { gigeTable 1 } 
 | 
						|
 | 
						|
   GigeEntry ::= SEQUENCE { 
 | 
						|
   	  gigeIndex			   INTEGER,		-- boardIndex
 | 
						|
      gigeSdhBandwidth     BandwidthSize,
 | 
						|
      gigeAutoTest		   SagemBoolean,
 | 
						|
      gigeWarmStart		   SagemBoolean
 | 
						|
   }
 | 
						|
 | 
						|
   gigeIndex   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "A unique value which identify a particular	gigabitEthernet card of the equipment.
 | 
						|
	The value of this index is a constant value assigned to an entry at
 | 
						|
	equipment design time. It is usualy related to harware"  
 | 
						|
      ::= { gigeEntry 1 } 
 | 
						|
   
 | 
						|
   gigeSdhBandwidth   OBJECT-TYPE
 | 
						|
      SYNTAX       BandwidthSize
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "This field set the size of the SDH Bandwidth which is allocated to the gigabitEthernet card."  
 | 
						|
      ::= { gigeEntry 2 } 
 | 
						|
   
 | 
						|
   gigeAutoTest   OBJECT-TYPE
 | 
						|
      SYNTAX       SagemBoolean
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "When the value of this field is set to true, an autotest is executed on the gigabitEthernet card."  
 | 
						|
      ::= { gigeEntry 3 } 
 | 
						|
 | 
						|
   gigeWarmStart   OBJECT-TYPE
 | 
						|
      SYNTAX       SagemBoolean
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "When the value of this field is set to true, a warmStart is launched on the gigabitEthernet card."  
 | 
						|
      ::= { gigeEntry 4 } 
 | 
						|
 | 
						|
   -- End of gige description     
 | 
						|
     
 | 
						|
 | 
						|
--*******************************************************************
 | 
						|
--* Maintenance part  
 | 
						|
--*******************************************************************  
 | 
						|
 | 
						|
   LoopbackGE    ::= INTEGER 
 | 
						|
   { 
 | 
						|
   	none(0),     -- GE-SDH Bidirectionnal Transmission 
 | 
						|
   	local1(1),   -- GE-GE Loopback (above GFP)
 | 
						|
   	local2(2),   -- GE-GE Loopback (beyong GFP)
 | 
						|
   	local3(3),   -- GE-GE Loopback (into SERDES)
 | 
						|
   	local4(4),   -- GE-GE Loopback (into GMAC Bloc)
 | 
						|
   	remote(10)   -- SDH-SDH Loopback (into Tramer)
 | 
						|
   }
 | 
						|
   
 | 
						|
   
 | 
						|
   maintenanceNumber   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"Number of gigabitEthernet ports in equipment."  
 | 
						|
      ::= { gige 20 } 
 | 
						|
   
 | 
						|
   maintenanceTable   OBJECT-TYPE
 | 
						|
      SYNTAX       SEQUENCE OF MaintenanceEntry
 | 
						|
      MAX-ACCESS   not-accessible
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"List of gigabitEthernet ports in equipment."  
 | 
						|
      ::= { gige 21 } 
 | 
						|
   
 | 
						|
   maintenanceEntry   OBJECT-TYPE
 | 
						|
      SYNTAX       MaintenanceEntry
 | 
						|
      MAX-ACCESS   not-accessible
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"A particular gigabitEthernet port of the equipment." 
 | 
						|
      INDEX        { maintenanceIndex  } 
 | 
						|
      ::= { maintenanceTable 1 } 
 | 
						|
 | 
						|
   MaintenanceEntry ::= SEQUENCE { 
 | 
						|
   	  maintenanceIndex			   	INTEGER,		-- channelIndex = nspiTTPIndex
 | 
						|
      maintenanceAutoTest		   	SagemBoolean,
 | 
						|
      maintenanceLoopback			LoopbackGE,
 | 
						|
      maintenancePRBSSent			DisplayString,
 | 
						|
      maintenancePRBSReceived 	    DisplayString,
 | 
						|
      maintenanceResetAllCounters	SagemBoolean,
 | 
						|
      maintenanceResetLanCounters	SagemBoolean,      
 | 
						|
      maintenanceResetGfpCounters	SagemBoolean,      
 | 
						|
      maintenanceResetQosCounters	SagemBoolean                  
 | 
						|
   }
 | 
						|
 | 
						|
   maintenanceIndex   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "A unique value which identify a particular	gigabitEthernet port of the equipment.
 | 
						|
	The value of this index is a constant value assigned to an entry at
 | 
						|
	equipment design time. It is usualy related to harware"  
 | 
						|
      ::= { maintenanceEntry 1 } 
 | 
						|
   
 | 
						|
   maintenanceAutoTest   OBJECT-TYPE
 | 
						|
      SYNTAX       SagemBoolean
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "When the value of this field is set to true, an autotest is executed on the gigabitEthernet port."  
 | 
						|
      ::= { maintenanceEntry 2 } 
 | 
						|
 | 
						|
   maintenanceLoopback   OBJECT-TYPE
 | 
						|
      SYNTAX       LoopbackGE
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "This field set a loopback mode to a particular gigabitEthernet port."  
 | 
						|
      ::= { maintenanceEntry 3 } 
 | 
						|
   
 | 
						|
   maintenancePRBSSent   OBJECT-TYPE
 | 
						|
      SYNTAX       DisplayString
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "This field allows to sent a PRBS frame on a particular gigabitEthernet port."  
 | 
						|
      ::= { maintenanceEntry 4 } 
 | 
						|
   
 | 
						|
   maintenancePRBSReceived   OBJECT-TYPE
 | 
						|
      SYNTAX       DisplayString
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "The value is the actual PRBS frame received in the particular gigabitEthernet port."  
 | 
						|
      ::= { maintenanceEntry 5 } 
 | 
						|
 | 
						|
   maintenanceResetAllCounters   OBJECT-TYPE
 | 
						|
      SYNTAX       SagemBoolean
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "When the value of this field is set to true, all counters attached to this interface are deleted."  
 | 
						|
      ::= { maintenanceEntry 6 } 
 | 
						|
 | 
						|
   maintenanceResetLanCounters   OBJECT-TYPE
 | 
						|
      SYNTAX       SagemBoolean
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "When the value of this field is set to true, all QoS counters attached to this interface are deleted."  
 | 
						|
      ::= { maintenanceEntry 7 } 
 | 
						|
 | 
						|
   maintenanceResetGfpCounters   OBJECT-TYPE
 | 
						|
      SYNTAX       SagemBoolean
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "When the value of this field is set to true, all Gfp counters attached to this interface are deleted."  
 | 
						|
      ::= { maintenanceEntry 8 } 
 | 
						|
 | 
						|
   maintenanceResetQosCounters   OBJECT-TYPE
 | 
						|
      SYNTAX       SagemBoolean
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "When the value of this field is set to true, all Qos counters attached to this interface are deleted."  
 | 
						|
      ::= { maintenanceEntry 9 } 
 | 
						|
   
 | 
						|
   -- End of maintenance part     
 | 
						|
 
 | 
						|
 | 
						|
--*******************************************************************
 | 
						|
--* QoS part  
 | 
						|
--*******************************************************************      
 | 
						|
 | 
						|
   QosType    ::= INTEGER 
 | 
						|
   { 
 | 
						|
   	none(0),     
 | 
						|
   	pauseMode(1),
 | 
						|
   	userPriority(2),
 | 
						|
   	vlanId(3),
 | 
						|
   	balanced(4),   
 | 
						|
   	ipv4TOS(10),
 | 
						|
   	ipv6TClass(11),
 | 
						|
   	dscp(13)
 | 
						|
   }
 | 
						|
   
 | 
						|
   CongestionControl    ::= INTEGER 
 | 
						|
   { 
 | 
						|
   	none(0),     
 | 
						|
   	red(1),    -- Random Early Detection 
 | 
						|
   	wred(2)    -- Weighted Random Early Detection
 | 
						|
   }
 | 
						|
 | 
						|
   SchedulingSystem    ::= INTEGER 
 | 
						|
   { 
 | 
						|
   	unknown(0),     
 | 
						|
   	spq(1),    -- Strict Priority Queuing
 | 
						|
   	wfq(4),    -- Weighted Fair Queuing
 | 
						|
    cbwfq(5),  -- Class-Based Weighted Fair Queuing
 | 
						|
    wrr(10)	   -- Weighted Round Robbin
 | 
						|
   }
 | 
						|
 | 
						|
   
 | 
						|
   qosNumber   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"Number of Quality of Service set in equipment. This number match to channelNumber because
 | 
						|
	there is only one Qos per Sdh Channel.
 | 
						|
	= number of entries in qosTable"  
 | 
						|
      ::= { gige 30 } 
 | 
						|
   
 | 
						|
   qosTable   OBJECT-TYPE
 | 
						|
      SYNTAX       SEQUENCE OF QosEntry
 | 
						|
      MAX-ACCESS   not-accessible
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"List of Qos in equipment."  
 | 
						|
      ::= { gige 31 } 
 | 
						|
   
 | 
						|
   qosEntry   OBJECT-TYPE
 | 
						|
      SYNTAX       QosEntry
 | 
						|
      MAX-ACCESS   not-accessible
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"A particular qos of the equipment." 
 | 
						|
      INDEX        { qosIndex  } 
 | 
						|
      ::= { qosTable 1 } 
 | 
						|
 | 
						|
   QosEntry ::= SEQUENCE { 
 | 
						|
   	  qosIndex				   	INTEGER,		-- channelIndex = nspiTTPIndex
 | 
						|
      qosClassNumber		   	INTEGER,
 | 
						|
      qosType					QosType,
 | 
						|
      qosCongestionControl		CongestionControl,
 | 
						|
      qosSchedulingSystem		SchedulingSystem,
 | 
						|
      qosBwREnable		 	    SagemBoolean,
 | 
						|
      qosHCInCCDiscardsGe		Counter64,      
 | 
						|
      qosHCInCCDiscardsWan		Counter64      
 | 
						|
   }
 | 
						|
 | 
						|
   qosIndex   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "A unique value which identify a particular	QoS of the equipment.
 | 
						|
	The value of this index is a constant value assigned to an entry at
 | 
						|
	equipment design time. It is usualy related to harware"  
 | 
						|
      ::= { qosEntry 1 } 
 | 
						|
   
 | 
						|
   qosClassNumber   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "This field allows to choose the number of CoS defined for the QoS"  
 | 
						|
      ::= { qosEntry 2 } 
 | 
						|
 | 
						|
   qosType   OBJECT-TYPE
 | 
						|
      SYNTAX       QosType
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "This field allows to choose the type of Qos"  
 | 
						|
      ::= { qosEntry 3 } 
 | 
						|
   
 | 
						|
   qosCongestionControl   OBJECT-TYPE
 | 
						|
      SYNTAX       CongestionControl
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "This field allows to choose a mechanism to manage congestion problems. Some Type of Qos
 | 
						|
        force the value of this field. "  
 | 
						|
      ::= { qosEntry 4 }  
 | 
						|
      
 | 
						|
   qosSchedulingSystem   OBJECT-TYPE
 | 
						|
      SYNTAX       SchedulingSystem
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "This field allows to choose a mechanism to manage congestion problems. "  
 | 
						|
      ::= { qosEntry 5 } 
 | 
						|
      
 | 
						|
   qosBwREnable   OBJECT-TYPE
 | 
						|
      SYNTAX       SagemBoolean
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "This field allows to activate or desactivate the Sdh throughput reservation feature. "  
 | 
						|
      ::= { qosEntry 6 } 
 | 
						|
     
 | 
						|
   qosHCInCCDiscardsGe   OBJECT-TYPE
 | 
						|
      SYNTAX       Counter64
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "The number of packets received on the GE interface which were discarded to prevent from switch saturation"  
 | 
						|
      ::= { qosEntry 7 } 
 | 
						|
 | 
						|
   qosHCInCCDiscardsWan   OBJECT-TYPE
 | 
						|
      SYNTAX       Counter64
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "The number of packets received on the WAN interface which were discarded to prevent from switch saturation"  
 | 
						|
      ::= { qosEntry 8 } 
 | 
						|
   
 | 
						|
   -- End of QoS part     
 | 
						|
 | 
						|
 | 
						|
 | 
						|
 | 
						|
--*******************************************************************
 | 
						|
--* CoS part  
 | 
						|
--*******************************************************************  
 | 
						|
 | 
						|
   CosId    ::= INTEGER 
 | 
						|
   { 
 | 
						|
   	cos0(0),     
 | 
						|
   	cos1(1),   
 | 
						|
   	cos2(2),
 | 
						|
   	cos3(3),
 | 
						|
   	cos4(4),
 | 
						|
   	cos5(5),
 | 
						|
   	cos6(6),
 | 
						|
   	cos7(7)
 | 
						|
   }
 | 
						|
   
 | 
						|
   cosNumber   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"Number of Class of Service set in equipment
 | 
						|
	= number of entries in cosTable 
 | 
						|
	= qosNumber * qosClassNumber"  
 | 
						|
      ::= { gige 40 } 
 | 
						|
   
 | 
						|
   cosTable   OBJECT-TYPE
 | 
						|
      SYNTAX       SEQUENCE OF CosEntry
 | 
						|
      MAX-ACCESS   not-accessible
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"List of CoS in equipment."  
 | 
						|
      ::= { gige 41 } 
 | 
						|
   
 | 
						|
   cosEntry   OBJECT-TYPE
 | 
						|
      SYNTAX       CosEntry
 | 
						|
      MAX-ACCESS   not-accessible
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"A particular CoS of the equipment." 
 | 
						|
      INDEX        { cosIndex  } 
 | 
						|
      ::= { cosTable 1 } 
 | 
						|
 | 
						|
   CosEntry ::= SEQUENCE { 
 | 
						|
   	  cosIndex				   	INTEGER,		
 | 
						|
   	  cosQosId				   	INTEGER,                   -- qosIndex
 | 
						|
      cosId						CosId,
 | 
						|
      cosDefinition				DisplayString,
 | 
						|
      cosBwRRatioMin	 	    INTEGER,
 | 
						|
      cosBwRRatioMax	 	    INTEGER,
 | 
						|
      cosHCInOctets				Counter64,      
 | 
						|
      cosHCOutOctets			Counter64,      
 | 
						|
      cosHCInPkts				Counter64,      
 | 
						|
      cosHCOutPkts				Counter64,      
 | 
						|
      cosHCInCCDiscards			Counter64      
 | 
						|
   }
 | 
						|
 | 
						|
   cosIndex   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "A unique value which identify a particular	CoS of the equipment.
 | 
						|
	The value of this index is a constant value assigned to an entry at
 | 
						|
	equipment design time. It is usualy related to harware. Its values are taken between 1 and cosNumber."  
 | 
						|
      ::= { cosEntry 1 } 
 | 
						|
   
 | 
						|
   cosQosId   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "This field allows to identify which QoS this Class is belonging. Its values must match to qosIndex."  
 | 
						|
      ::= { cosEntry 2 } 
 | 
						|
 | 
						|
   cosId   OBJECT-TYPE
 | 
						|
      SYNTAX       CosId
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        " This field identify the class of Service."  
 | 
						|
      ::= { cosEntry 3 } 
 | 
						|
   
 | 
						|
   cosDefinition   OBJECT-TYPE
 | 
						|
      SYNTAX       DisplayString
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "This optional textual field brings some precisions about the CoS configuration. "  
 | 
						|
      ::= { cosEntry 4 } 
 | 
						|
   
 | 
						|
   cosBwRRatioMin   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "When the qosBwREnable field is set to True, then this field allows to configure the guaranted percentage of SDH
 | 
						|
        throughput which must be booked up for the CoS"  
 | 
						|
      ::= { cosEntry 5 } 
 | 
						|
 | 
						|
   cosBwRRatioMax   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "When the qosBwREnable field is set to True, then this field allows to configure the maximum percentage of SDH
 | 
						|
        throughput which can be booked up for the CoS"  
 | 
						|
      ::= { cosEntry 6 } 
 | 
						|
 | 
						|
   cosHCInOctets   OBJECT-TYPE
 | 
						|
      SYNTAX       Counter64
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "The total number of octets received on the GE interface (excluding framing characters preambule and sfd)
 | 
						|
         and belonging to a CosId packet"  
 | 
						|
      ::= { cosEntry 7 } 
 | 
						|
 | 
						|
   cosHCOutOctets   OBJECT-TYPE
 | 
						|
      SYNTAX       Counter64
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "The total number of octets transmitted out of the Wan interface (excluding framing characters preambule and sfd)
 | 
						|
         and belonging to a CosId paket"  
 | 
						|
      ::= { cosEntry 8 } 
 | 
						|
 | 
						|
   cosHCInPkts   OBJECT-TYPE
 | 
						|
      SYNTAX       Counter64
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "The total number of octets received on the GE interface (excluding framing characters preambule and sfd)
 | 
						|
         and belonging to a CosId packet"  
 | 
						|
      ::= { cosEntry 9 } 
 | 
						|
 | 
						|
   cosHCOutPkts   OBJECT-TYPE
 | 
						|
      SYNTAX       Counter64
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "The total number of octets transmitted out of the Wan interface (excluding framing characters preambule and sfd)
 | 
						|
         and belonging to a CosId paket"  
 | 
						|
      ::= { cosEntry 10 } 
 | 
						|
 | 
						|
   cosHCInCCDiscards   OBJECT-TYPE
 | 
						|
      SYNTAX       Counter64
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "The number of CosId packets received on the GE interface which were discarded by RED/WRED/BandWidthReservation
 | 
						|
         to prevent from congestion."  
 | 
						|
      ::= { cosEntry 11 } 
 | 
						|
   
 | 
						|
   -- End of CoS part     
 | 
						|
 | 
						|
 | 
						|
--*******************************************************************
 | 
						|
--* GFP part  
 | 
						|
--*******************************************************************  
 | 
						|
 | 
						|
   GfpFailure    ::= INTEGER 
 | 
						|
   { 
 | 
						|
   	none(0),     
 | 
						|
   	oofd(1),   
 | 
						|
   	lofd(2),
 | 
						|
   	fdsc(3)
 | 
						|
   }
 | 
						|
 | 
						|
   GfpState    ::= INTEGER(0..2147483647) 
 | 
						|
  -- { 
 | 
						|
  -- 	none(0),     
 | 
						|
  -- 	(1),   
 | 
						|
  -- 	(2),
 | 
						|
  -- 	(3)
 | 
						|
  -- }
 | 
						|
    
 | 
						|
   gfpNumber   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"ports Number of the Gfp layer.
 | 
						|
	= number of entries in gfpTable "  
 | 
						|
      ::= { gige 50 } 
 | 
						|
   
 | 
						|
   gfpTable   OBJECT-TYPE
 | 
						|
      SYNTAX       SEQUENCE OF GfpEntry
 | 
						|
      MAX-ACCESS   not-accessible
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"List of gfp port in the equipment."  
 | 
						|
      ::= { gige 51 } 
 | 
						|
   
 | 
						|
   gfpEntry   OBJECT-TYPE
 | 
						|
      SYNTAX       GfpEntry
 | 
						|
      MAX-ACCESS   not-accessible
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"A particular gfp port of the equipment." 
 | 
						|
      INDEX        { gfpIndex  } 
 | 
						|
      ::= { gfpTable 1 } 
 | 
						|
 | 
						|
   GfpEntry ::= SEQUENCE { 
 | 
						|
   	  gfpIndex				   	INTEGER,		 -- channelIndex
 | 
						|
      gfpHCInPkts				Counter64,
 | 
						|
      gfpHCInIdlePkts			Counter64,
 | 
						|
      gfpHCInCorruptedPkts 	    Counter64,
 | 
						|
      gfpHCInErrors		 	    Counter64,
 | 
						|
      gfpHCInCorrectedPkts 	    Counter64,
 | 
						|
      gfpHCFCSErrors			Counter64,      
 | 
						|
      gfpHCInOctets				Counter64,      
 | 
						|
      gfpHCOutPkts				Counter64,
 | 
						|
      gfpHCOutIdlePkts			Counter64,
 | 
						|
      gfpHCOutOctets			Counter64,
 | 
						|
      gfpIdleRate				INTEGER,
 | 
						|
      gfpSendingRate			INTEGER,
 | 
						|
   	  gfpState				   	GfpState,         
 | 
						|
      gfpAdminStatus			INTEGER,
 | 
						|
      gfpOperStatus				INTEGER,
 | 
						|
      gfpMonitor				SagemBoolean,
 | 
						|
      gfpFailure				GfpFailure,
 | 
						|
      gfpSeverity				Severity,
 | 
						|
      gfpOOFD					Severity,
 | 
						|
      gfpLOFD					Severity,
 | 
						|
      gfpFDSC					Severity
 | 
						|
   }
 | 
						|
 | 
						|
   gfpIndex   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "A unique value which identify a particular	gfp port in the equipment.
 | 
						|
	The value of this index is a constant value assigned to an entry at
 | 
						|
	equipment design time. It is usualy related to harware. Its values are mapped to channelIndex values."  
 | 
						|
      ::= { gfpEntry 1 } 
 | 
						|
   
 | 
						|
   gfpHCInPkts   OBJECT-TYPE
 | 
						|
      SYNTAX       Counter64
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        " The total number of packets received on the Gfp interface"  
 | 
						|
      ::= { gfpEntry 2 } 
 | 
						|
   
 | 
						|
   gfpHCInIdlePkts   OBJECT-TYPE
 | 
						|
      SYNTAX       Counter64
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
         " The total number of Idle frames received on the Gfp interface"  
 | 
						|
      ::= { gfpEntry 3 } 
 | 
						|
   
 | 
						|
   gfpHCInCorruptedPkts   OBJECT-TYPE
 | 
						|
      SYNTAX       Counter64
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        " The total number of mismatched packets received on the Gfp interface."  
 | 
						|
      ::= { gfpEntry 4 } 
 | 
						|
 | 
						|
   gfpHCInErrors   OBJECT-TYPE
 | 
						|
      SYNTAX       Counter64
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "The total number of mismatched packets that have been discarded. "  
 | 
						|
      ::= { gfpEntry 5 } 
 | 
						|
 | 
						|
   gfpHCInCorrectedPkts   OBJECT-TYPE
 | 
						|
      SYNTAX       Counter64
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "The total number of mismatched packets received on the Gfp interface that have been corrected. "  
 | 
						|
      ::= { gfpEntry 6 } 
 | 
						|
     
 | 
						|
   gfpHCFCSErrors   OBJECT-TYPE
 | 
						|
      SYNTAX       Counter64
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "The number of frames received on the Gfp interface that are an integral number of octets
 | 
						|
         in length but do not pass the FCS check. "  
 | 
						|
      ::= { gfpEntry 7 } 
 | 
						|
 | 
						|
   gfpHCInOctets   OBJECT-TYPE
 | 
						|
      SYNTAX       Counter64
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        " The total number of Octets received on the Gfp interface"  
 | 
						|
      ::= { gfpEntry 8 } 
 | 
						|
      
 | 
						|
   gfpHCOutPkts   OBJECT-TYPE
 | 
						|
      SYNTAX       Counter64
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        " The total number of packets transmitted out of the Gfp interface"  
 | 
						|
      ::= { gfpEntry 9 } 
 | 
						|
       
 | 
						|
   gfpHCOutIdlePkts   OBJECT-TYPE
 | 
						|
      SYNTAX       Counter64
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        " The total number of Idle frame transmitted out of the Gfp interface"  
 | 
						|
      ::= { gfpEntry 10 } 
 | 
						|
 | 
						|
   gfpHCOutOctets   OBJECT-TYPE
 | 
						|
      SYNTAX       Counter64
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        " The total number of packets transmitted out of the Gfp interface"  
 | 
						|
      ::= { gfpEntry 11 } 
 | 
						|
 | 
						|
   gfpIdleRate   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        " The received Idle frames rate on a particular gfp port. "  
 | 
						|
      ::= { gfpEntry 12 } 
 | 
						|
 
 | 
						|
   gfpSendingRate   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        " The sent frames rate on a particular gfp port. "  
 | 
						|
      ::= { gfpEntry 13 } 
 | 
						|
 | 
						|
   gfpState   OBJECT-TYPE
 | 
						|
      SYNTAX       GfpState
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "This field allows to know in which state this gfp port is working."  
 | 
						|
      ::= { gfpEntry 14 } 
 | 
						|
 | 
						|
    gfpAdminStatus   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER {
 | 
						|
                      up(1),       -- ready to pass packets
 | 
						|
                      down(2),
 | 
						|
                      testing(3)   -- in some test mode
 | 
						|
                   }
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"The desired state of the gfp port.  The
 | 
						|
     testing(3) state indicates that no operational
 | 
						|
     packets can be passed."  
 | 
						|
      ::= { gfpEntry 15 } 
 | 
						|
 | 
						|
   gfpOperStatus   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER {
 | 
						|
                     up(1),       -- ready to pass packets
 | 
						|
                     down(2),
 | 
						|
                     testing(3)   -- in some test mode
 | 
						|
                   }
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"The current operational state of the gfp port.
 | 
						|
     The testing(3) state indicates that no operational
 | 
						|
     packets can be passed."  
 | 
						|
      ::= { gfpEntry 16 }          
 | 
						|
      
 | 
						|
   gfpMonitor   OBJECT-TYPE
 | 
						|
      SYNTAX       SagemBoolean
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"When the value of this field is set to false, the failure detection
 | 
						|
	is stopped for this gfp port."  
 | 
						|
      ::= { gfpEntry 17 } 
 | 
						|
   
 | 
						|
   gfpFailure   OBJECT-TYPE
 | 
						|
      SYNTAX       GfpFailure
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "Active failures on channel"  
 | 
						|
      ::= { gfpEntry 18 } 
 | 
						|
   
 | 
						|
   gfpSeverity   OBJECT-TYPE
 | 
						|
      SYNTAX       Severity
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "A reference to failure severity for gfp port."  
 | 
						|
      ::= { gfpEntry 19 }    
 | 
						|
         
 | 
						|
   gfpOOFD   OBJECT-TYPE
 | 
						|
      SYNTAX       Severity
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"Severity associated with Out of Frame Delineation failure
 | 
						|
	for gfp port."  
 | 
						|
      ::= { gfpEntry 20 }     
 | 
						|
  
 | 
						|
   gfpLOFD   OBJECT-TYPE
 | 
						|
      SYNTAX       Severity
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"Severity associated with Loss Of Frame Delineation failure
 | 
						|
	for gfp port."  
 | 
						|
      ::= { gfpEntry 21 } 
 | 
						|
   
 | 
						|
   gfpFDSC   OBJECT-TYPE
 | 
						|
      SYNTAX       Severity
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"Severity associated with Frame Delineation State Change failure
 | 
						|
	for gfp port."  
 | 
						|
      ::= { gfpEntry 22 }
 | 
						|
-- End of GFP part     
 | 
						|
    
 | 
						|
 | 
						|
--*******************************************************************
 | 
						|
--* PAUSE part  
 | 
						|
--*******************************************************************  
 | 
						|
 | 
						|
   PauseFailure    ::= INTEGER 
 | 
						|
   { 
 | 
						|
   	none(0),     
 | 
						|
   	pauseModeRejected(1)
 | 
						|
   }
 | 
						|
    
 | 
						|
   pauseNumber   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"Number of ports in the equipment which accept Pause mechanism
 | 
						|
	= number of entries in pauseTable "  
 | 
						|
      ::= { gige 60 } 
 | 
						|
   
 | 
						|
   pauseTable   OBJECT-TYPE
 | 
						|
      SYNTAX       SEQUENCE OF PauseEntry
 | 
						|
      MAX-ACCESS   not-accessible
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"List of Ethernet port in the equipment which accept Pause mechanism."  
 | 
						|
      ::= { gige 61 } 
 | 
						|
   
 | 
						|
   pauseEntry   OBJECT-TYPE
 | 
						|
      SYNTAX       PauseEntry
 | 
						|
      MAX-ACCESS   not-accessible
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"A particular Ethernet port of the equipment." 
 | 
						|
      INDEX        { pauseIndex  } 
 | 
						|
      ::= { pauseTable 1 } 
 | 
						|
 | 
						|
   PauseEntry ::= SEQUENCE { 
 | 
						|
   	  pauseIndex				INTEGER,		 -- Lan ifIndex
 | 
						|
   	  pauseTime				   	INTEGER,         
 | 
						|
      pauseBetweenTime			INTEGER,
 | 
						|
      pauseMacSA				PhysAddress,
 | 
						|
      pauseMacDA 	    		PhysAddress,
 | 
						|
      pauseCHT		 	    	INTEGER,
 | 
						|
      pauseCLT 	    			INTEGER,
 | 
						|
      pauseMonitor				SagemBoolean,      
 | 
						|
      pauseFailure				PauseFailure,      
 | 
						|
      pauseSeverity				Severity,
 | 
						|
      pauseModeRejected			Severity
 | 
						|
   }
 | 
						|
 | 
						|
   pauseIndex   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "A unique value which identify a particular	Ethernet Physical port of a gigabitEthernet card.
 | 
						|
	The value of this index is a constant value assigned to an entry at
 | 
						|
	equipment design time. It is usualy related to harware. Its values are mapped to IfIndex values of Lan Ports."  
 | 
						|
      ::= { pauseEntry 1 } 
 | 
						|
   
 | 
						|
   pauseTime   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "This field allows to set the Time during which the linkPartner stop any transmission. The Unit used is the time slot
 | 
						|
        (= 512 ns)."  
 | 
						|
      ::= { pauseEntry 2 } 
 | 
						|
 | 
						|
   pauseBetweenTime   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "This field allows to set the Time between two Pause Frames transmission. The Unit used is the time slot
 | 
						|
        (= 512 ns)."  
 | 
						|
      ::= { pauseEntry 3 } 
 | 
						|
   
 | 
						|
   pauseMacSA   OBJECT-TYPE
 | 
						|
      SYNTAX       PhysAddress
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
         " The physical address of the Ethernet port.
 | 
						|
         This address is used to fill the SourceAddress field of any Pause Frame which is trasmitted by the LinkPartner."  
 | 
						|
      ::= { pauseEntry 4 } 
 | 
						|
   
 | 
						|
   pauseMacDA   OBJECT-TYPE
 | 
						|
      SYNTAX       PhysAddress
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
         " The physical address used to fill the DestinationAddress field of any Pause Frame which is transmitted by the LinkPartner."  
 | 
						|
      ::= { pauseEntry 5 } 
 | 
						|
 | 
						|
   pauseCHT   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "This field allows to configure the credit High Threshold of Pause mechanism."  
 | 
						|
      ::= { pauseEntry 6 } 
 | 
						|
 | 
						|
   pauseCLT   OBJECT-TYPE
 | 
						|
      SYNTAX       INTEGER(0..2147483647)
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "This field allows to configure the credit Low Threshold of Pause mechanism."  
 | 
						|
      ::= { pauseEntry 7 } 
 | 
						|
     
 | 
						|
   pauseMonitor   OBJECT-TYPE
 | 
						|
      SYNTAX       SagemBoolean
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"When the value of this field is set to false, the failure detection
 | 
						|
	is stopped for this Ethernet port."  
 | 
						|
      ::= { pauseEntry 10 } 
 | 
						|
   
 | 
						|
   pauseFailure   OBJECT-TYPE
 | 
						|
      SYNTAX       PauseFailure
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "Active failures in the pause mechanism of the Ethernet port."  
 | 
						|
      ::= { pauseEntry 11 } 
 | 
						|
   
 | 
						|
   pauseSeverity   OBJECT-TYPE
 | 
						|
      SYNTAX       Severity
 | 
						|
      MAX-ACCESS   read-only
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
        "A reference to severity associated to the current pause failure."  
 | 
						|
      ::= { pauseEntry 12 }    
 | 
						|
         
 | 
						|
   pauseModeRejected   OBJECT-TYPE
 | 
						|
      SYNTAX       Severity
 | 
						|
      MAX-ACCESS   read-write
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION 
 | 
						|
	"This field allows to configure the Severity associated with Pause Mode Rejected failure
 | 
						|
	for Ethernet port."  
 | 
						|
      ::= { pauseEntry 13 } 
 | 
						|
   
 | 
						|
-- End of Pause part     
 | 
						|
 | 
						|
 | 
						|
END
 | 
						|
 | 
						|
 | 
						|
 | 
						|
 |