mibs/MIBS/siae/SIAE-PMG828-MIB

592 lines
19 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- ----------------------------------------------------------------------------
--
-- SIAE MICROELETTRONICA s.p.a.
--
-- Via Michelangelo Buonarroti, 21
-- 20093 - Cologno Monzese
-- Milano
-- ITALY
--
-- ----------------------------------------------------------------------------
-- ----------------------------------------------------------------------------
SIAE-PMG828-MIB
DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Counter32, Integer32, Unsigned32
FROM SNMPv2-SMI
DisplayString, RowStatus
FROM SNMPv2-TC
siaeMib
FROM SIAE-TREE-MIB
AlarmStatus, AlarmSeverityCode
FROM SIAE-ALARM-MIB;
pmG828 MODULE-IDENTITY
LAST-UPDATED "201410070000Z"
ORGANIZATION "SIAE MICROELETTRONICA spa"
CONTACT-INFO
"SIAE MICROELETTONICA s.p.a.
Via Michelangelo Buonarroti, 21
20093 - Cologno Monzese
Milano - ITALY
Phone : +39-02-27325-1
E-mail: tbd@siaemic.com
"
DESCRIPTION
"Perforfamce Monitoring according to ITU-T G.829 for Radio Link
and E1 Tributaries
"
REVISION "201410070000Z"
DESCRIPTION
"Changed MAX-ACCESS caluse of some object of pmG828TpClassTable
from read-write to read-create
"
REVISION "201402030000Z"
DESCRIPTION
"Improved description of pmG828MibVersion
"
REVISION "201304160000Z"
DESCRIPTION
"Initial version 01.00.00
"
::= { siaeMib 11 }
----------------------------------------------------------------------------------
-- object identifier inside the module
----------------------------------------------------------------------------------
----------------------------------------------------------------------------------
-- pmG828 (PDH PERFORMANCE MONITORING G.828) GROUP
----------------------------------------------------------------------------------
--
-- The following objects are used to manage the Pdh G.828 Performance Monitoring
-- function.
--
----------------------------------------------------------------------------------
------ Beginning --------------------------------------------------------------
--
------- The following table contains the records with the counters used to evaluate
------- the Performance Monitoring of the radio according to G.828 specification.
------- Begin of pmG828CounterTable
--
pmG828MibVersion OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Numerical version of this module.
The string version of this MIB have the following format:
XX.YY.ZZ
so, for example, the value 1 should be interpreted as 00.00.01
and the value 10001 should be interpreted as 01.00.01."
DEFVAL {1}
::= {pmG828 1}
pmG828CounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmG828CounterRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with PmG828 records: one record for 1+0 configuration and two
record for 1+1 configuration."
::= {pmG828 2}
pmG828CounterRecord OBJECT-TYPE
SYNTAX PmG828CounterRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PmG828Counter record."
INDEX {pmG828TPointId, pmG828CounterBlockId}
::= {pmG828CounterTable 1}
PmG828CounterRecord ::=
SEQUENCE {
pmG828TPointId Integer32,
pmG828CounterBlockId Integer32,
pmG828CounterBlockType INTEGER,
pmG828CounterBlockStatus INTEGER,
pmG828CounterTimeStamp Unsigned32,
pmG828BBECounter Counter32,
pmG828ESCounter Counter32,
pmG828SESCounter Counter32,
pmG828UASCounter Counter32,
pmG828SEPCounter Counter32
}
pmG828TPointId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the Termination Point."
::= {pmG828CounterRecord 1}
pmG828CounterBlockId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the counters block and the counter type
according to the following code:
1 Current Daily counters
2 Daily counters (Day before counters)
3 Current 15 minutes counters
4 15 minutes counters N. 1 (The most recent 15 minutes counters)
..............................................
n 15 minutes counters N. n
20 15 minutes counters N.16(The oldest 15 min.counters 4 hours before)."
::= {pmG828CounterRecord 2}
pmG828CounterBlockType OBJECT-TYPE
SYNTAX INTEGER {
daily (1),
fifteenMin (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the counter block."
::= {pmG828CounterRecord 3}
pmG828CounterBlockStatus OBJECT-TYPE
SYNTAX INTEGER {
meaningless (1),
meaningfull (2),
incomplete (3),
dummy (4),
lost (5),
restarted (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the block counter."
::= {pmG828CounterRecord 4}
pmG828CounterTimeStamp OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object is the time when the performance record is closed reported
as the second number since 1-Gen-1970."
::= {pmG828CounterRecord 5}
pmG828BBECounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"G828 BBE counter."
::= {pmG828CounterRecord 6}
pmG828ESCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"G828 Es counter."
::= {pmG828CounterRecord 7}
pmG828SESCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"G828 SES counter."
::= {pmG828CounterRecord 8}
pmG828UASCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"G828 UAS counter."
::= {pmG828CounterRecord 9}
pmG828SEPCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"G828 SEP counter."
::= {pmG828CounterRecord 10}
--
------- End of pmG828CounterTable
--
------- The following table contains the records used to manage the P.M. on both
------- radio branch and the threshold cross alarms
------- Begin of pmG828TpClassTable
--
pmG828TpClassTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmG828TpClassRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with PmG828TpClass records: one record for 1+0 configuration and
two record for 1+1 configuration."
::= {pmG828 3}
pmG828TpClassRecord OBJECT-TYPE
SYNTAX PmG828TpClassRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PmG828TpClass record."
INDEX {pmG828TpClassId}
::= {pmG828TpClassTable 1}
PmG828TpClassRecord ::=
SEQUENCE {
pmG828TpClassId Integer32,
pmG828TpClassStartStop INTEGER,
pmG828TpClassLabel DisplayString,
pmG828TpClassTimeStamp Unsigned32,
pmG828TpClass15MEsAlarm AlarmStatus,
pmG828TpClass15MSesAlarm AlarmStatus,
pmG828TpClass15MSepAlarm AlarmStatus,
pmG828TpClass24HEsAlarm AlarmStatus,
pmG828TpClass24HSesAlarm AlarmStatus,
pmG828TpClass24HSepAlarm AlarmStatus,
pmG828TpClassUasAlarm AlarmStatus,
pmG828TpClass15MEsThreshold Integer32,
pmG828TpClass15MSesThreshold Integer32,
pmG828TpClass15MSepThreshold Integer32,
pmG828TpClass24HEsThreshold Integer32,
pmG828TpClass24HSesThreshold Integer32,
pmG828TpClass24HSepThreshold Integer32,
pmG828TpClassRowStatus RowStatus
}
pmG828TpClassId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the Termination Point."
::= {pmG828TpClassRecord 1}
pmG828TpClassStartStop OBJECT-TYPE
SYNTAX INTEGER {
start (1),
stop (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to start and to stop the Perfomance Monitoring
counter evaluation."
::= {pmG828TpClassRecord 2}
pmG828TpClassLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ASCII string used to identify the Tp class:
for example:
pmG828TpClassBranchId = 1 label = Radio 1
pmG828TpClassBranchId = 2 label = Radio 2
pmG828TpClassBranchId = 3 label = Radio(switched)
pmG828TpClassBranchId = 4 label = Trib E1 line side
pmG828TpClassBranchId = 5 label = Trib E1 radio side."
::= {pmG828TpClassRecord 3}
pmG828TpClassTimeStamp OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= {pmG828TpClassRecord 4}
pmG828TpClass15MEsAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"15 minutes ES threshold cross alarm with associated severity."
::= {pmG828TpClassRecord 5}
pmG828TpClass15MSesAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"15 minutes SES threshold cross alarm with associated severity."
::= {pmG828TpClassRecord 6}
pmG828TpClass15MSepAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"15 minutes SEP threshold cross alarm with associated severity."
::= {pmG828TpClassRecord 7}
pmG828TpClass24HEsAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Daily ES threshold cross alarm with associated severity."
::= {pmG828TpClassRecord 8}
pmG828TpClass24HSesAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Daily SES threshold cross alarm with associated severity."
::= {pmG828TpClassRecord 9}
pmG828TpClass24HSepAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Daily SEP threshold cross alarm with associated severity."
::= {pmG828TpClassRecord 10}
pmG828TpClassUasAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"UAS alarm with associated severity."
::= {pmG828TpClassRecord 11}
pmG828TpClass15MEsThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of ES within 15 minutes to set pmG828TpClass15MEsAlarm
(zero value disables the alarm)."
DEFVAL {0}
::= {pmG828TpClassRecord 12}
pmG828TpClass15MSesThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of SES within 15 minutes to set pmG828TpClass15MSesAlarm
(zero value disables the alarm)."
DEFVAL {0}
::= {pmG828TpClassRecord 13}
pmG828TpClass15MSepThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of SEP within 15 minutes to set pmG828TpClass15MSepAlarm
(zero value disables the alarm)."
DEFVAL {0}
::= {pmG828TpClassRecord 14}
pmG828TpClass24HEsThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of ES within one day to set pmG828TpClass24HEsAlarm
(zero value disables the alarm)."
DEFVAL {0}
::= {pmG828TpClassRecord 15}
pmG828TpClass24HSesThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of SES within one day to set pmG828TpClass24HSesAlarm
(zero value disables the alarm)."
DEFVAL {0}
::= {pmG828TpClassRecord 16}
pmG828TpClass24HSepThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of SEP within one day to set pmG828TpClass24HSepAlarm
(zero value disables the alarm)."
DEFVAL {0}
::= {pmG828TpClassRecord 17}
pmG828TpClassRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Status of this row of pmRxPwrTpClass.
"
::= {pmG828TpClassRecord 18}
--
------- End of pmG828TpClassTable
--
-- MAINTENANCE TABLE
--
------- Begin of pmG828TpMaintTable
--
pmG828TpMaintTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmG828TpMaintRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with Command for maintenance of Termination Point.
Objects in this table is not persistent. An Instance of this
table is created on creation of pmG828TpClassTable"
::= {pmG828 4}
pmG828TpMaintRecord OBJECT-TYPE
SYNTAX PmG828TpMaintRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PmG828 Termination Point Maintenance record."
INDEX {pmG828TpClassId}
::= {pmG828TpMaintTable 1}
PmG828TpMaintRecord ::=
SEQUENCE {
pmG828TpMaintCounterClear INTEGER,
pmG828TpMaintAlarmClear INTEGER
}
pmG828TpMaintCounterClear OBJECT-TYPE
SYNTAX INTEGER {
notActive (0),
clear (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to clear the Perfomance Monitoring counters."
::= {pmG828TpMaintRecord 1}
pmG828TpMaintAlarmClear OBJECT-TYPE
SYNTAX INTEGER {
notActive (0),
clear (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to clear the Perfomance Monitoring threshold cross alarms."
::= {pmG828TpMaintRecord 2}
--
------- End of pmG828TpMaintTable
--
------- The following objects are common to all instances.
--
pmG828NSesSetUAS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of SES (according G.828) to set UAS."
DEFVAL {10}
::= {pmG828 5}
pmG828NSesResetUAS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of seconds whitout errors (according G.828) to reset UAS."
DEFVAL {10}
::= {pmG828 6}
pmG828TpClass15MEsAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the pmG828TpClass15MEsAlarm and
enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {pmG828 7}
pmG828TpClass15MSesAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the pmG828TpClass15MSesAlarm and
enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {pmG828 8}
pmG828TpClass24HEsAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the pmG828TpClass15MEsAlarm and
enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {pmG828 9}
pmG828TpClass24HSesAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the pmG828TpClass15MSesAlarm and
enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {pmG828 10}
pmG828TpClassUASAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the pmG828TpClassUASAlarm and
enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {pmG828 11}
pmG828TpClass15MSepAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the pmG828TpClass15MSepAlarm and
enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {pmG828 12}
pmG828TpClass24HSepAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the pmG828TpClass24HSepAlarm and
enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {pmG828 13}
------ End group -----------------------------------------------------------------
END