mibs/MIBS/siae/SIAE-PMTXPWR-MIB

608 lines
20 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- ----------------------------------------------------------------------------
--
-- SIAE MICROELETTRONICA s.p.a.
--
-- Via Michelangelo Buonarroti, 21
-- 20093 - Cologno Monzese
-- Milano
-- ITALY
--
-- ----------------------------------------------------------------------------
-- ----------------------------------------------------------------------------
SIAE-PMTXPWR-MIB
DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Counter32, Integer32, Unsigned32
FROM SNMPv2-SMI
DisplayString, RowStatus
FROM SNMPv2-TC
siaeMib
FROM SIAE-TREE-MIB
AlarmStatus, AlarmSeverityCode
FROM SIAE-ALARM-MIB;
pmTxPwr MODULE-IDENTITY
LAST-UPDATED "201410070000Z"
ORGANIZATION "SIAE MICROELETTRONICA spa"
CONTACT-INFO
"SIAE MICROELETTONICA s.p.a.
Via Michelangelo Buonarroti, 21
20093 - Cologno Monzese
Milano - ITALY
Phone : +39-02-27325-1
E-mail: tbd@siaemic.com
"
DESCRIPTION
"Performance Monitoring on Transmitted (TX) RF Power.
"
REVISION "201410070000Z"
DESCRIPTION
"Changed MAX-ACCESS caluse of some object of pmTxPwrTpClassTable
from read-write to read-create
"
REVISION "201402030000Z"
DESCRIPTION
"Improved description of pmTxPwrMibVersion
"
REVISION "201304160000Z"
DESCRIPTION
"Initial version 01.00.00
"
::= { siaeMib 13 }
----------------------------------------------------------------------------------
-- object identifier inside the module
----------------------------------------------------------------------------------
----------------------------------------------------------------------------------
-- pmTxPwr (PERFORMANCE MONITORING TRANSMITTED POWER LEVEL) GROUP
----------------------------------------------------------------------------------
--
-- The following objects are used to manage the Transmitted Power Performance
-- Monitoring function.
--
----------------------------------------------------------------------------------
------ Beginning --------------------------------------------------------------
--
------- The following table contains the records with the counters used to monitor
------- the Transmitted power of the radio.
------- Begin of pmTxPwrCounterTable
--
pmTxPwrMibVersion OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Numerical version of this module.
The string version of this MIB have the following format:
XX.YY.ZZ
so, for example, the value 1 should be interpreted as 00.00.01
and the value 10001 should be interpreted as 01.00.01."
DEFVAL {1}
::= {pmTxPwr 1}
pmTxPwrCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmTxPwrCounterRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with PmTxPwr records: one record for 1+0 configuration and two
record for 1+1 configuration."
::= {pmTxPwr 2}
pmTxPwrCounterRecord OBJECT-TYPE
SYNTAX PmTxPwrCounterRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PmTxPwrCounter record."
INDEX {pmTxPwrBranchId, pmTxPwrCounterBlockId}
::= {pmTxPwrCounterTable 1}
PmTxPwrCounterRecord ::=
SEQUENCE {
pmTxPwrBranchId Integer32,
pmTxPwrCounterBlockId Integer32,
pmTxPwrCounterBlockType INTEGER,
pmTxPwrCounterBlockStatus INTEGER,
pmTxPwrCounterTimeStamp Unsigned32,
pmTxPwrTlts1Counter Counter32,
pmTxPwrTlts2Counter Counter32,
pmTxPwrTlts3Counter Counter32,
pmTxPwrTlts4Counter Counter32,
pmTxPwrTMMax Integer32,
pmTxPwrTMMin Integer32,
pmTxPwrAverageTxLevel Integer32
}
pmTxPwrBranchId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the Radio Branch"
::= {pmTxPwrCounterRecord 1}
pmTxPwrCounterBlockId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the counters block and the counter type according to the following code:
1 Current Daily counters
2 Daily counters (Day before counters)
3 Current 15 minutes counters
4 15 minutes counters N. 1 (The most recent 15 minutes counters)
..............................................
n 15 minutes counters N. n
19 15 minutes counters N. 16 (The oldest 15 minutes counters - 4 hours before)."
::= {pmTxPwrCounterRecord 2}
pmTxPwrCounterBlockType OBJECT-TYPE
SYNTAX INTEGER {
daily (1),
fifteenMin (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the counter block."
::= {pmTxPwrCounterRecord 3}
pmTxPwrCounterBlockStatus OBJECT-TYPE
SYNTAX INTEGER {
meaningless (1),
meaningfull (2),
incomplete (3),
dummy (4),
lost (5),
restarted (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"block counter status."
::= {pmTxPwrCounterRecord 4}
pmTxPwrCounterTimeStamp OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object is the time when the performance record is closed reported
as the second number since 1-Gen-1970."
::= {pmTxPwrCounterRecord 5}
pmTxPwrTlts1Counter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of seconds when the Transmitted power is greater than the threshold 1."
::= {pmTxPwrCounterRecord 6}
pmTxPwrTlts2Counter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of seconds when the Transmitted power is greater than the threshold 2"
::= {pmTxPwrCounterRecord 7}
pmTxPwrTlts3Counter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of seconds when the Transmitted power is greater than the threshold 3"
::= {pmTxPwrCounterRecord 8}
pmTxPwrTlts4Counter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of seconds when the Transmitted power is greater than the threshold 4"
::= {pmTxPwrCounterRecord 9}
pmTxPwrTMMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum Transmitted Power Level Tide Mark."
::= {pmTxPwrCounterRecord 10}
pmTxPwrTMMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum Transmitted Power Level Tide Mark."
::= {pmTxPwrCounterRecord 11}
pmTxPwrAverageTxLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Power Transmitted Level (Average value)"
::= { pmTxPwrCounterRecord 12}
--
------- End of pmTxPwrCounterTable
--
------- The following table contains the records used to manage the P.M. on both
------- radio branch and the threshold cross alarms
------- Begin of pmTxPwrTpClassTable
--
pmTxPwrTpClassTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmTxPwrTpClassRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with PmTxPwrTpClass records: one record for 1+0 configuration and two record
for 1+1 configuration."
::= {pmTxPwr 3}
pmTxPwrTpClassRecord OBJECT-TYPE
SYNTAX PmTxPwrTpClassRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PmTxPwrTpClass record."
INDEX {pmTxPwrTpClassBranchId}
::= {pmTxPwrTpClassTable 1}
PmTxPwrTpClassRecord ::=
SEQUENCE {
pmTxPwrTpClassBranchId Integer32,
pmTxPwrTpClassStartStop INTEGER,
pmTxPwrTpClassLabel DisplayString,
pmTxPwrTpClassTimeStamp Unsigned32,
pmTxPwrTpClass15MTlts1Alarm AlarmStatus,
pmTxPwrTpClass15MTlts2Alarm AlarmStatus,
pmTxPwrTpClass15MTlts3Alarm AlarmStatus,
pmTxPwrTpClass15MTlts4Alarm AlarmStatus,
pmTxPwrTpClass24HTlts1Alarm AlarmStatus,
pmTxPwrTpClass24HTlts2Alarm AlarmStatus,
pmTxPwrTpClass24HTlts3Alarm AlarmStatus,
pmTxPwrTpClass24HTlts4Alarm AlarmStatus,
pmTxPwrTpClassTlt1Threshold INTEGER,
pmTxPwrTpClassTlt2Threshold INTEGER,
pmTxPwrTpClassTlt3Threshold INTEGER,
pmTxPwrTpClassTlt4Threshold INTEGER,
pmTxPwrTpClass15MTlts1Threshold Integer32,
pmTxPwrTpClass15MTlts2Threshold Integer32,
pmTxPwrTpClass15MTlts3Threshold Integer32,
pmTxPwrTpClass15MTlts4Threshold Integer32,
pmTxPwrTpClass24HTlts1Threshold Integer32,
pmTxPwrTpClass24HTlts2Threshold Integer32,
pmTxPwrTpClass24HTlts3Threshold Integer32,
pmTxPwrTpClass24HTlts4Threshold Integer32,
pmTxPwrTpClassRowStatus RowStatus
}
pmTxPwrTpClassBranchId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the Radio Branch"
::= {pmTxPwrTpClassRecord 1}
pmTxPwrTpClassStartStop OBJECT-TYPE
SYNTAX INTEGER {
start (1),
stop (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to start and to stop the Perfomance Monitoring
counter evaluation."
::= {pmTxPwrTpClassRecord 2}
pmTxPwrTpClassLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ASCII string used to identify the Tp class:
pmTxPwrTpClassBranchId = 1 label = Radio 1
pmTxPwrTpClassBranchId = 2 label = Radio 2."
::= {pmTxPwrTpClassRecord 3}
pmTxPwrTpClassTimeStamp OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object is the time when the performance record is closed reported
as the second number since 1/1/70."
::= {pmTxPwrTpClassRecord 4}
pmTxPwrTpClass15MTlts1Alarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"15 minutes Tlts1 threshold cross alarm with associated severity."
::= {pmTxPwrTpClassRecord 5}
pmTxPwrTpClass15MTlts2Alarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"15 minutes Tlts2 threshold cross alarm with associated severity."
::= {pmTxPwrTpClassRecord 6}
pmTxPwrTpClass15MTlts3Alarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"15 minutes Tlts3 threshold cross alarm with associated severity."
::= {pmTxPwrTpClassRecord 7}
pmTxPwrTpClass15MTlts4Alarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"15 minutes Tlts4 threshold cross alarm with associated severity."
::= {pmTxPwrTpClassRecord 8}
pmTxPwrTpClass24HTlts1Alarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Daily Tlts1 threshold cross alarm with associated severity."
::= {pmTxPwrTpClassRecord 9}
pmTxPwrTpClass24HTlts2Alarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Daily Tlts2 threshold cross alarm with associated severity."
::= {pmTxPwrTpClassRecord 10}
pmTxPwrTpClass24HTlts3Alarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Daily Tlts3 threshold cross alarm with associated severity."
::= {pmTxPwrTpClassRecord 11}
pmTxPwrTpClass24HTlts4Alarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Daily Tlts4 threshold cross alarm with associated severity."
::= {pmTxPwrTpClassRecord 12}
pmTxPwrTpClassTlt1Threshold OBJECT-TYPE
SYNTAX INTEGER (-100..-20)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Received Power Level Threshold 1 (dBm value); range -100 to -20"
DEFVAL {-30}
::= {pmTxPwrTpClassRecord 13}
pmTxPwrTpClassTlt2Threshold OBJECT-TYPE
SYNTAX INTEGER (-100..-20)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Received Power Level Threshold 2 (dBm value); range -100 to -20"
DEFVAL {-40}
::= {pmTxPwrTpClassRecord 14}
pmTxPwrTpClassTlt3Threshold OBJECT-TYPE
SYNTAX INTEGER (-100..-20)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Received Power Level Threshold 3 (dBm value); range -100 to -20"
DEFVAL {-50}
::= {pmTxPwrTpClassRecord 15}
pmTxPwrTpClassTlt4Threshold OBJECT-TYPE
SYNTAX INTEGER (-100..-20)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Received Power Level Threshold 4 (dBm value); range -100 to -20"
DEFVAL {-60}
::= {pmTxPwrTpClassRecord 16}
pmTxPwrTpClass15MTlts1Threshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of seconds within 15 minutes to set
pmTxPwrTpClass15MTlts1Alarm (zero value disables the alarm)."
DEFVAL {0}
::= {pmTxPwrTpClassRecord 17}
pmTxPwrTpClass15MTlts2Threshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of seconds within 15 minutes to set
pmTxPwrTpClass15MTlts2Alarm (zero value disables the alarm)."
DEFVAL {0}
::= {pmTxPwrTpClassRecord 18}
pmTxPwrTpClass15MTlts3Threshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of seconds within 15 minutes to set
pmTxPwrTpClass15MTlts3Alarm (zero value disables the alarm)."
DEFVAL {0}
::= {pmTxPwrTpClassRecord 19}
pmTxPwrTpClass15MTlts4Threshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of seconds within 15 minutes to set
pmTxPwrTpClass15MTlts4Alarm (zero value disables the alarm)."
DEFVAL {0}
::= {pmTxPwrTpClassRecord 20}
pmTxPwrTpClass24HTlts1Threshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of seconds within a day to set pmTxPwrTpClass24HTlts1Alarm
(zero value disables the alarm)."
DEFVAL {0}
::= {pmTxPwrTpClassRecord 21}
pmTxPwrTpClass24HTlts2Threshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of seconds within a day to set pmTxPwrTpClass24HTlts2Alarm
(zero value disables the alarm)."
DEFVAL {0}
::= {pmTxPwrTpClassRecord 22}
pmTxPwrTpClass24HTlts3Threshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of seconds within a day to set pmTxPwrTpClass24HTlts3Alarm
(zero value disables the alarm)."
DEFVAL {0}
::= {pmTxPwrTpClassRecord 23}
pmTxPwrTpClass24HTlts4Threshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of seconds within a day to set pmTxPwrTpClass24HTlts4Alarm
(zero value disables the alarm)."
DEFVAL {0}
::= {pmTxPwrTpClassRecord 24}
pmTxPwrTpClassRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Status of this row of pmTxPwrTpClass.
"
::= {pmTxPwrTpClassRecord 25}
--
------- End of pmTxPwrTpClassTable
--
-- MAINTENANCE TABLE
--
------- Begin of PmTxPwrTpMaintRecord
--
pmTxPwrTpMaintTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmTxPwrTpMaintRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with Command for maintenance of Termination Point.
Objects in this table is not persistent. An Instance of this
table is created on creation of pmTxPwrTpClassTable"
::= {pmTxPwr 4}
pmTxPwrTpMaintRecord OBJECT-TYPE
SYNTAX PmTxPwrTpMaintRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PmG828 Termination Point Maintenance record."
INDEX {pmTxPwrTpClassBranchId}
::= {pmTxPwrTpMaintTable 1}
PmTxPwrTpMaintRecord ::=
SEQUENCE {
pmTxPwrTpMaintCounterClear INTEGER,
pmTxPwrTpMaintAlarmClear INTEGER
}
pmTxPwrTpMaintCounterClear OBJECT-TYPE
SYNTAX INTEGER {
notActive (0),
clear (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to clear the Perfomance Monitoring counters."
::= {pmTxPwrTpMaintRecord 1}
pmTxPwrTpMaintAlarmClear OBJECT-TYPE
SYNTAX INTEGER {
notActive (0),
clear (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to clear the Perfomance Monitoring threshold cross alarms."
::= {pmTxPwrTpMaintRecord 2}
--
------- End of PmTxPwrTpMaintRecord
--
------- The following objects are common to all radio branches.
--
pmTxPwrTpClass15MTltsAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the pmTxPwrTpClass15MTltsAlarm
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {pmTxPwr 5}
pmTxPwrTpClass24HTltsAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the pmTxPwrTpClass24HTltsAlarm
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {pmTxPwr 6}
------ End group -----------------------------------------------------------------
END