608 lines
20 KiB
Plaintext
608 lines
20 KiB
Plaintext
-- ----------------------------------------------------------------------------
|
|
--
|
|
-- SIAE MICROELETTRONICA s.p.a.
|
|
--
|
|
-- Via Michelangelo Buonarroti, 21
|
|
-- 20093 - Cologno Monzese
|
|
-- Milano
|
|
-- ITALY
|
|
--
|
|
-- ----------------------------------------------------------------------------
|
|
-- ----------------------------------------------------------------------------
|
|
|
|
SIAE-PMTXPWR-MIB
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
Counter32, Integer32, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
DisplayString, RowStatus
|
|
FROM SNMPv2-TC
|
|
siaeMib
|
|
FROM SIAE-TREE-MIB
|
|
AlarmStatus, AlarmSeverityCode
|
|
FROM SIAE-ALARM-MIB;
|
|
|
|
pmTxPwr MODULE-IDENTITY
|
|
LAST-UPDATED "201410070000Z"
|
|
ORGANIZATION "SIAE MICROELETTRONICA spa"
|
|
CONTACT-INFO
|
|
"SIAE MICROELETTONICA s.p.a.
|
|
Via Michelangelo Buonarroti, 21
|
|
20093 - Cologno Monzese
|
|
Milano - ITALY
|
|
Phone : +39-02-27325-1
|
|
E-mail: tbd@siaemic.com
|
|
"
|
|
DESCRIPTION
|
|
"Performance Monitoring on Transmitted (TX) RF Power.
|
|
"
|
|
REVISION "201410070000Z"
|
|
DESCRIPTION
|
|
"Changed MAX-ACCESS caluse of some object of pmTxPwrTpClassTable
|
|
from read-write to read-create
|
|
"
|
|
REVISION "201402030000Z"
|
|
DESCRIPTION
|
|
"Improved description of pmTxPwrMibVersion
|
|
"
|
|
REVISION "201304160000Z"
|
|
DESCRIPTION
|
|
"Initial version 01.00.00
|
|
"
|
|
::= { siaeMib 13 }
|
|
|
|
----------------------------------------------------------------------------------
|
|
-- object identifier inside the module
|
|
----------------------------------------------------------------------------------
|
|
|
|
----------------------------------------------------------------------------------
|
|
-- pmTxPwr (PERFORMANCE MONITORING TRANSMITTED POWER LEVEL) GROUP
|
|
----------------------------------------------------------------------------------
|
|
--
|
|
-- The following objects are used to manage the Transmitted Power Performance
|
|
-- Monitoring function.
|
|
--
|
|
----------------------------------------------------------------------------------
|
|
|
|
------ Beginning --------------------------------------------------------------
|
|
|
|
--
|
|
------- The following table contains the records with the counters used to monitor
|
|
------- the Transmitted power of the radio.
|
|
------- Begin of pmTxPwrCounterTable
|
|
--
|
|
|
|
pmTxPwrMibVersion OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Numerical version of this module.
|
|
The string version of this MIB have the following format:
|
|
XX.YY.ZZ
|
|
so, for example, the value 1 should be interpreted as 00.00.01
|
|
and the value 10001 should be interpreted as 01.00.01."
|
|
DEFVAL {1}
|
|
::= {pmTxPwr 1}
|
|
|
|
pmTxPwrCounterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PmTxPwrCounterRecord
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table with PmTxPwr records: one record for 1+0 configuration and two
|
|
record for 1+1 configuration."
|
|
::= {pmTxPwr 2}
|
|
|
|
pmTxPwrCounterRecord OBJECT-TYPE
|
|
SYNTAX PmTxPwrCounterRecord
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PmTxPwrCounter record."
|
|
INDEX {pmTxPwrBranchId, pmTxPwrCounterBlockId}
|
|
::= {pmTxPwrCounterTable 1}
|
|
|
|
PmTxPwrCounterRecord ::=
|
|
SEQUENCE {
|
|
pmTxPwrBranchId Integer32,
|
|
pmTxPwrCounterBlockId Integer32,
|
|
pmTxPwrCounterBlockType INTEGER,
|
|
pmTxPwrCounterBlockStatus INTEGER,
|
|
pmTxPwrCounterTimeStamp Unsigned32,
|
|
pmTxPwrTlts1Counter Counter32,
|
|
pmTxPwrTlts2Counter Counter32,
|
|
pmTxPwrTlts3Counter Counter32,
|
|
pmTxPwrTlts4Counter Counter32,
|
|
pmTxPwrTMMax Integer32,
|
|
pmTxPwrTMMin Integer32,
|
|
pmTxPwrAverageTxLevel Integer32
|
|
}
|
|
|
|
pmTxPwrBranchId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the Radio Branch"
|
|
::= {pmTxPwrCounterRecord 1}
|
|
|
|
pmTxPwrCounterBlockId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the counters block and the counter type according to the following code:
|
|
1 Current Daily counters
|
|
2 Daily counters (Day before counters)
|
|
3 Current 15 minutes counters
|
|
4 15 minutes counters N. 1 (The most recent 15 minutes counters)
|
|
..............................................
|
|
n 15 minutes counters N. n
|
|
19 15 minutes counters N. 16 (The oldest 15 minutes counters - 4 hours before)."
|
|
::= {pmTxPwrCounterRecord 2}
|
|
|
|
pmTxPwrCounterBlockType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
daily (1),
|
|
fifteenMin (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of the counter block."
|
|
::= {pmTxPwrCounterRecord 3}
|
|
|
|
pmTxPwrCounterBlockStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
meaningless (1),
|
|
meaningfull (2),
|
|
incomplete (3),
|
|
dummy (4),
|
|
lost (5),
|
|
restarted (6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"block counter status."
|
|
::= {pmTxPwrCounterRecord 4}
|
|
|
|
pmTxPwrCounterTimeStamp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object is the time when the performance record is closed reported
|
|
as the second number since 1-Gen-1970."
|
|
::= {pmTxPwrCounterRecord 5}
|
|
|
|
pmTxPwrTlts1Counter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds when the Transmitted power is greater than the threshold 1."
|
|
::= {pmTxPwrCounterRecord 6}
|
|
|
|
pmTxPwrTlts2Counter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds when the Transmitted power is greater than the threshold 2"
|
|
::= {pmTxPwrCounterRecord 7}
|
|
|
|
pmTxPwrTlts3Counter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds when the Transmitted power is greater than the threshold 3"
|
|
::= {pmTxPwrCounterRecord 8}
|
|
|
|
pmTxPwrTlts4Counter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds when the Transmitted power is greater than the threshold 4"
|
|
::= {pmTxPwrCounterRecord 9}
|
|
|
|
pmTxPwrTMMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum Transmitted Power Level Tide Mark."
|
|
::= {pmTxPwrCounterRecord 10}
|
|
|
|
pmTxPwrTMMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum Transmitted Power Level Tide Mark."
|
|
::= {pmTxPwrCounterRecord 11}
|
|
|
|
pmTxPwrAverageTxLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Power Transmitted Level (Average value)"
|
|
::= { pmTxPwrCounterRecord 12}
|
|
--
|
|
------- End of pmTxPwrCounterTable
|
|
|
|
--
|
|
------- The following table contains the records used to manage the P.M. on both
|
|
------- radio branch and the threshold cross alarms
|
|
------- Begin of pmTxPwrTpClassTable
|
|
--
|
|
pmTxPwrTpClassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PmTxPwrTpClassRecord
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table with PmTxPwrTpClass records: one record for 1+0 configuration and two record
|
|
for 1+1 configuration."
|
|
::= {pmTxPwr 3}
|
|
|
|
pmTxPwrTpClassRecord OBJECT-TYPE
|
|
SYNTAX PmTxPwrTpClassRecord
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PmTxPwrTpClass record."
|
|
INDEX {pmTxPwrTpClassBranchId}
|
|
::= {pmTxPwrTpClassTable 1}
|
|
|
|
PmTxPwrTpClassRecord ::=
|
|
SEQUENCE {
|
|
pmTxPwrTpClassBranchId Integer32,
|
|
pmTxPwrTpClassStartStop INTEGER,
|
|
pmTxPwrTpClassLabel DisplayString,
|
|
pmTxPwrTpClassTimeStamp Unsigned32,
|
|
pmTxPwrTpClass15MTlts1Alarm AlarmStatus,
|
|
pmTxPwrTpClass15MTlts2Alarm AlarmStatus,
|
|
pmTxPwrTpClass15MTlts3Alarm AlarmStatus,
|
|
pmTxPwrTpClass15MTlts4Alarm AlarmStatus,
|
|
pmTxPwrTpClass24HTlts1Alarm AlarmStatus,
|
|
pmTxPwrTpClass24HTlts2Alarm AlarmStatus,
|
|
pmTxPwrTpClass24HTlts3Alarm AlarmStatus,
|
|
pmTxPwrTpClass24HTlts4Alarm AlarmStatus,
|
|
pmTxPwrTpClassTlt1Threshold INTEGER,
|
|
pmTxPwrTpClassTlt2Threshold INTEGER,
|
|
pmTxPwrTpClassTlt3Threshold INTEGER,
|
|
pmTxPwrTpClassTlt4Threshold INTEGER,
|
|
pmTxPwrTpClass15MTlts1Threshold Integer32,
|
|
pmTxPwrTpClass15MTlts2Threshold Integer32,
|
|
pmTxPwrTpClass15MTlts3Threshold Integer32,
|
|
pmTxPwrTpClass15MTlts4Threshold Integer32,
|
|
pmTxPwrTpClass24HTlts1Threshold Integer32,
|
|
pmTxPwrTpClass24HTlts2Threshold Integer32,
|
|
pmTxPwrTpClass24HTlts3Threshold Integer32,
|
|
pmTxPwrTpClass24HTlts4Threshold Integer32,
|
|
pmTxPwrTpClassRowStatus RowStatus
|
|
}
|
|
|
|
pmTxPwrTpClassBranchId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the Radio Branch"
|
|
::= {pmTxPwrTpClassRecord 1}
|
|
|
|
pmTxPwrTpClassStartStop OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
start (1),
|
|
stop (2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to start and to stop the Perfomance Monitoring
|
|
counter evaluation."
|
|
::= {pmTxPwrTpClassRecord 2}
|
|
|
|
pmTxPwrTpClassLabel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ASCII string used to identify the Tp class:
|
|
pmTxPwrTpClassBranchId = 1 label = Radio 1
|
|
pmTxPwrTpClassBranchId = 2 label = Radio 2."
|
|
::= {pmTxPwrTpClassRecord 3}
|
|
|
|
pmTxPwrTpClassTimeStamp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object is the time when the performance record is closed reported
|
|
as the second number since 1/1/70."
|
|
::= {pmTxPwrTpClassRecord 4}
|
|
|
|
pmTxPwrTpClass15MTlts1Alarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"15 minutes Tlts1 threshold cross alarm with associated severity."
|
|
::= {pmTxPwrTpClassRecord 5}
|
|
|
|
pmTxPwrTpClass15MTlts2Alarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"15 minutes Tlts2 threshold cross alarm with associated severity."
|
|
::= {pmTxPwrTpClassRecord 6}
|
|
|
|
pmTxPwrTpClass15MTlts3Alarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"15 minutes Tlts3 threshold cross alarm with associated severity."
|
|
::= {pmTxPwrTpClassRecord 7}
|
|
|
|
pmTxPwrTpClass15MTlts4Alarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"15 minutes Tlts4 threshold cross alarm with associated severity."
|
|
::= {pmTxPwrTpClassRecord 8}
|
|
|
|
pmTxPwrTpClass24HTlts1Alarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Daily Tlts1 threshold cross alarm with associated severity."
|
|
::= {pmTxPwrTpClassRecord 9}
|
|
|
|
pmTxPwrTpClass24HTlts2Alarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Daily Tlts2 threshold cross alarm with associated severity."
|
|
::= {pmTxPwrTpClassRecord 10}
|
|
|
|
pmTxPwrTpClass24HTlts3Alarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Daily Tlts3 threshold cross alarm with associated severity."
|
|
::= {pmTxPwrTpClassRecord 11}
|
|
|
|
pmTxPwrTpClass24HTlts4Alarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Daily Tlts4 threshold cross alarm with associated severity."
|
|
::= {pmTxPwrTpClassRecord 12}
|
|
|
|
pmTxPwrTpClassTlt1Threshold OBJECT-TYPE
|
|
SYNTAX INTEGER (-100..-20)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received Power Level Threshold 1 (dBm value); range -100 to -20"
|
|
DEFVAL {-30}
|
|
::= {pmTxPwrTpClassRecord 13}
|
|
|
|
pmTxPwrTpClassTlt2Threshold OBJECT-TYPE
|
|
SYNTAX INTEGER (-100..-20)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received Power Level Threshold 2 (dBm value); range -100 to -20"
|
|
DEFVAL {-40}
|
|
::= {pmTxPwrTpClassRecord 14}
|
|
|
|
pmTxPwrTpClassTlt3Threshold OBJECT-TYPE
|
|
SYNTAX INTEGER (-100..-20)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received Power Level Threshold 3 (dBm value); range -100 to -20"
|
|
DEFVAL {-50}
|
|
::= {pmTxPwrTpClassRecord 15}
|
|
|
|
pmTxPwrTpClassTlt4Threshold OBJECT-TYPE
|
|
SYNTAX INTEGER (-100..-20)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received Power Level Threshold 4 (dBm value); range -100 to -20"
|
|
DEFVAL {-60}
|
|
::= {pmTxPwrTpClassRecord 16}
|
|
|
|
pmTxPwrTpClass15MTlts1Threshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds within 15 minutes to set
|
|
pmTxPwrTpClass15MTlts1Alarm (zero value disables the alarm)."
|
|
DEFVAL {0}
|
|
::= {pmTxPwrTpClassRecord 17}
|
|
|
|
pmTxPwrTpClass15MTlts2Threshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds within 15 minutes to set
|
|
pmTxPwrTpClass15MTlts2Alarm (zero value disables the alarm)."
|
|
DEFVAL {0}
|
|
::= {pmTxPwrTpClassRecord 18}
|
|
|
|
pmTxPwrTpClass15MTlts3Threshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds within 15 minutes to set
|
|
pmTxPwrTpClass15MTlts3Alarm (zero value disables the alarm)."
|
|
DEFVAL {0}
|
|
::= {pmTxPwrTpClassRecord 19}
|
|
|
|
pmTxPwrTpClass15MTlts4Threshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds within 15 minutes to set
|
|
pmTxPwrTpClass15MTlts4Alarm (zero value disables the alarm)."
|
|
DEFVAL {0}
|
|
::= {pmTxPwrTpClassRecord 20}
|
|
|
|
pmTxPwrTpClass24HTlts1Threshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds within a day to set pmTxPwrTpClass24HTlts1Alarm
|
|
(zero value disables the alarm)."
|
|
DEFVAL {0}
|
|
::= {pmTxPwrTpClassRecord 21}
|
|
|
|
pmTxPwrTpClass24HTlts2Threshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds within a day to set pmTxPwrTpClass24HTlts2Alarm
|
|
(zero value disables the alarm)."
|
|
DEFVAL {0}
|
|
::= {pmTxPwrTpClassRecord 22}
|
|
|
|
pmTxPwrTpClass24HTlts3Threshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds within a day to set pmTxPwrTpClass24HTlts3Alarm
|
|
(zero value disables the alarm)."
|
|
DEFVAL {0}
|
|
::= {pmTxPwrTpClassRecord 23}
|
|
|
|
pmTxPwrTpClass24HTlts4Threshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds within a day to set pmTxPwrTpClass24HTlts4Alarm
|
|
(zero value disables the alarm)."
|
|
DEFVAL {0}
|
|
::= {pmTxPwrTpClassRecord 24}
|
|
|
|
pmTxPwrTpClassRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of this row of pmTxPwrTpClass.
|
|
"
|
|
::= {pmTxPwrTpClassRecord 25}
|
|
|
|
--
|
|
------- End of pmTxPwrTpClassTable
|
|
|
|
--
|
|
-- MAINTENANCE TABLE
|
|
--
|
|
|
|
------- Begin of PmTxPwrTpMaintRecord
|
|
--
|
|
pmTxPwrTpMaintTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PmTxPwrTpMaintRecord
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table with Command for maintenance of Termination Point.
|
|
Objects in this table is not persistent. An Instance of this
|
|
table is created on creation of pmTxPwrTpClassTable"
|
|
::= {pmTxPwr 4}
|
|
|
|
pmTxPwrTpMaintRecord OBJECT-TYPE
|
|
SYNTAX PmTxPwrTpMaintRecord
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PmG828 Termination Point Maintenance record."
|
|
INDEX {pmTxPwrTpClassBranchId}
|
|
::= {pmTxPwrTpMaintTable 1}
|
|
|
|
PmTxPwrTpMaintRecord ::=
|
|
SEQUENCE {
|
|
pmTxPwrTpMaintCounterClear INTEGER,
|
|
pmTxPwrTpMaintAlarmClear INTEGER
|
|
}
|
|
|
|
pmTxPwrTpMaintCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notActive (0),
|
|
clear (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to clear the Perfomance Monitoring counters."
|
|
::= {pmTxPwrTpMaintRecord 1}
|
|
|
|
pmTxPwrTpMaintAlarmClear OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notActive (0),
|
|
clear (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to clear the Perfomance Monitoring threshold cross alarms."
|
|
::= {pmTxPwrTpMaintRecord 2}
|
|
--
|
|
------- End of PmTxPwrTpMaintRecord
|
|
|
|
--
|
|
------- The following objects are common to all radio branches.
|
|
--
|
|
pmTxPwrTpClass15MTltsAlarmSeverityCode OBJECT-TYPE
|
|
SYNTAX AlarmSeverityCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Define the severity associated to the pmTxPwrTpClass15MTltsAlarm
|
|
and enables/disables the trap generation on status change event."
|
|
DEFVAL {majorTrapEnable}
|
|
::= {pmTxPwr 5}
|
|
|
|
pmTxPwrTpClass24HTltsAlarmSeverityCode OBJECT-TYPE
|
|
SYNTAX AlarmSeverityCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Define the severity associated to the pmTxPwrTpClass24HTltsAlarm
|
|
and enables/disables the trap generation on status change event."
|
|
DEFVAL {majorTrapEnable}
|
|
::= {pmTxPwr 6}
|
|
|
|
------ End group -----------------------------------------------------------------
|
|
|
|
END
|
|
|
|
|
|
|
|
|