mibs/MIBS/transition/TN-FRA-MIB

122 lines
3.6 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- *****************************************************************
-- TN-FRA-MIB.my : TN Fault Relay Alarm MIB
--
-- Copyright (c) 2012 by Transition Networks, Inc.
-- All rights reserved.
--
-- *****************************************************************
--
TN-FRA-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP FROM SNMPv2-CONF
entPhysicalIndex FROM ENTITY-MIB
ifIndex FROM IF-MIB
tnProducts FROM TRANSITION-SMI;
tnFraMIB MODULE-IDENTITY
LAST-UPDATED "201206251030Z"
ORGANIZATION "Transition Networks, Inc."
CONTACT-INFO
"Transition Networks
Technical Support
10900 Red Circle Drive
Minnetonka, MN 55343 USA
Tel: +1-800-526-9267
E-mail: techsupport@transition.com"
DESCRIPTION
"The mib module for managing all transition products with FRA(Fault relay alarm)"
REVISION "201206250000Z"
DESCRIPTION
"Initial version of this MIB module."
::= { tnProducts 21 }
tnFraObjects OBJECT IDENTIFIER
::= { tnFraMIB 1 }
tnFraMgmt OBJECT IDENTIFIER ::= { tnFraObjects 1 }
tnFraRelayAlarmState OBJECT-TYPE
SYNTAX INTEGER {normal(1),negated(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Change the state of the relay when an alarm condition is active
Normal (1): Relay is activated on alarm
Negated(2): Relay is de-activated on alarm
"
::= { tnFraMgmt 1 }
tnFraPowerSupplyTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnFraPowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used for configuring fault relay status of the powersupply modules"
::= { tnFraMgmt 2 }
tnFraPowerSupplyEntry OBJECT-TYPE
SYNTAX TnFraPowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entry contains configuration element of tnFraPowerSupplyTable"
INDEX { entPhysicalIndex }
::= { tnFraPowerSupplyTable 1 }
TnFraPowerSupplyEntry ::= SEQUENCE {
tnFraPowerSupplyState INTEGER
}
tnFraPowerSupplyState OBJECT-TYPE
SYNTAX INTEGER { enable(1),disable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trigger fault relay alarm while monitored power supply is not present
Enabled(1) : Enable fault relay alarm.
Disabled(2): Disable fault relay alarm.
"
::= { tnFraPowerSupplyEntry 1 }
tnFraLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnFraLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" This table is used for configuring fault relay status of the each port
"
::= { tnFraMgmt 3 }
tnFraLinkEntry OBJECT-TYPE
SYNTAX TnFraLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The entry list the tnFraLinkState priority of each port
"
INDEX { ifIndex }
::= { tnFraLinkTable 1 }
TnFraLinkEntry ::= SEQUENCE {
tnFraLinkState INTEGER
}
tnFraLinkState OBJECT-TYPE
SYNTAX INTEGER { enable(1),disable(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trigger fault relay alarm while monitored Port is down
Enabled(1) : Enable fault relay alarm of the link.
Disabled(2): Disable fault relay alarm of the link.
"
::= { tnFraLinkEntry 1}
END