mibs/MIBS/transition/TN-SYNCE-MIB

512 lines
14 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- ***********************************************************************************************
-- TN-SYNCE-MIB.smi: Transition Networks Enterprise MIB for TN device SyncE feature
--
-- Copyright (c) 2013 by Transition Networks, Inc.
-- All rights reserved.
--
-- ***********************************************************************************************
--
TN-SYNCE-MIB DEFINITIONS ::= BEGIN
IMPORTS
TruthValue FROM SNMPv2-TC
MODULE-IDENTITY,
OBJECT-IDENTITY,
entPhysicalIndex FROM ENTITY-MIB
tnProducts FROM TRANSITION-SMI;
tnSynceMIB MODULE-IDENTITY
LAST-UPDATED "201305160000Z"
ORGANIZATION "Transition Networks, Inc."
CONTACT-INFO
" Transition Networks
Technical Support
10900 Red Circle Drive
Minnetonka, MN 55343 USA
Tel: +1-800-526-9267
E-mail: techsupport@transition.com"
DESCRIPTION
"The mib provides functionalities for managing SyncE."
REVISION "201305160000Z"
DESCRIPTION
"Initial Revision of this module"
::= { tnProducts 122 }
tnSynce OBJECT IDENTIFIER ::= { tnSynceMIB 1 }
tnSyncETable OBJECT-TYPE
SYNTAX SEQUENCE OF TnSyncEEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table to manage SyncE for each device."
::= { tnSynce 1 }
tnSyncEEntry OBJECT-TYPE
SYNTAX TnSyncEEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing SyncE for each device."
INDEX { entPhysicalIndex }
::= { tnSyncETable 1 }
TnSyncEEntry ::=
SEQUENCE {
tnSyncEStateMode INTEGER,
tnSyncEStateWTRTime INTEGER,
tnSyncEStateSSMHoldOver INTEGER,
tnSyncEStateSSMFreeRun INTEGER,
tnSyncEAlarmStateLOL TruthValue,
tnSyncEAlarmStateDHOLD TruthValue,
tnSyncESelState INTEGER,
tnSyncEClkSrc INTEGER
}
tnSyncEStateMode OBJECT-TYPE
SYNTAX INTEGER
{
manual(1),
selected(2),
nonrevertive(3),
revertive(4),
holdover(5),
freerun(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Clock source selection mode
manual: Selector is manually set to the chosen clock source
selected: Selector is manually set to the pt. selected clock source (not possible in unlocked mode)
nonrevertive: Selector is automatically selecting the best clock source - non revertively
revertive: Selector is automatically selecting the best clock source - revertively
holdover: Selector is forced in holdover
freerun: Selector is forced in free run"
::= { tnSyncEEntry 1 }
tnSyncEStateWTRTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "WTR (Wait-to-Restore) time in minutes(0-12 min) '0' is disable"
::= { tnSyncEEntry 2 }
tnSyncEStateSSMHoldOver OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
prc(1),
ssua(2),
ssub(3),
eec2(4),
eec1(5),
dnu(6),
inv(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Synchronization Status Messaging Hold Over.
Hold Over is switching over to Local Reference Clock if primary and secondary nodes fail
prc = Primary Reference Clock
eec2 Ethernet Equipment Clock 1.544 kpbs
eec1 Ethernet Equipment Clock 2.048 kpbs"
::= { tnSyncEEntry 3 }
tnSyncEStateSSMFreeRun OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
prc(1),
ssua(2),
ssub(3),
eec2(4),
eec1(5),
dnu(6),
inv(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Synchronization Status Messaging Free Run"
::= { tnSyncEEntry 4 }
tnSyncEAlarmStateLOL OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm State Loss of Lock (LOL)"
::= { tnSyncEEntry 5 }
tnSyncEAlarmStateDHOLD OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Alarm State Digital Hold (DHOLD)"
::= { tnSyncEEntry 6 }
tnSyncESelState OBJECT-TYPE
SYNTAX INTEGER
{
lockedto(1),
holdover(2),
freerun(3),
prelock2(4),
prelock(5),
lossoflock(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Clock Selection State
Note: prelock2, prelock and lossoflock
are not available on all products"
::= { tnSyncEEntry 7 }
tnSyncEClkSrc OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Clock Source"
::= { tnSyncEEntry 8 }
--
-- SyncEClkSource
--
tnSyncEClkSourceTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnSyncEClkSourceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of SyncE ClkSource"
::= { tnSynce 2 }
tnSyncEClkSourceEntry OBJECT-TYPE
SYNTAX TnSyncEClkSourceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table,tnSyncEClkSourceTable"
INDEX { entPhysicalIndex, tnSyncEClkSourceIndex }
::= { tnSyncEClkSourceTable 1 }
TnSyncEClkSourceEntry ::= SEQUENCE
{
tnSyncEClkSourceIndex INTEGER,
tnSyncEConfPort INTEGER,
tnSyncEConfSSMOverwrite INTEGER,
tnSyncEConfHoldOff INTEGER,
tnSyncEConfANEG INTEGER,
tnSyncEPriority INTEGER,
tnSyncEClear TruthValue,
tnSyncEAlarmStateLOCS TruthValue,
tnSyncEAlarmStateSSM TruthValue,
tnSyncEAlarmStateWTR TruthValue,
tnSyncENominated TruthValue
}
tnSyncEClkSourceIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Index of SyncE ClkSource table. 1-SYNCE_NOMINATED_MAX"
::= { tnSyncEClkSourceEntry 1 }
tnSyncEConfPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SyncE Configuration Port. 0-MAX_PORT.
a port value of 0 means not nominated"
::= { tnSyncEClkSourceEntry 2 }
tnSyncEConfSSMOverwrite OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
prc(1),
ssua(2),
ssub(3),
eec2(4),
eec1(5),
dnu(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Clock source SSM overwrite"
::= { tnSyncEClkSourceEntry 3 }
tnSyncEConfHoldOff OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The hold off timer value in 100 ms.
Valid values are: 0 for disable. The range 3-18. The value 100 for test"
::= { tnSyncEClkSourceEntry 4 }
tnSyncEConfANEG OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
slave(1),
master(2),
forced(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Auto Negotiate : 1000BaseT ANEG mode
slave: Activate prefer slave negotiation
master: Activate prefer master negotiation
forced: Activate forced slave negotiation."
::= { tnSyncEClkSourceEntry 5 }
tnSyncEPriority OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Clock source priority setting. (SYNCE_PRIORITY_MAX = CLOCK_INPUT_MAX = 2 i.e. 0,1)"
::= { tnSyncEClkSourceEntry 6 }
tnSyncEClear OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SyncE Clear."
::= { tnSyncEClkSourceEntry 7 }
tnSyncEAlarmStateLOCS OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SyncE Alarm State LOCS."
::= { tnSyncEClkSourceEntry 8 }
tnSyncEAlarmStateSSM OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION " SyncE Alarm State SSM."
::= { tnSyncEClkSourceEntry 9 }
tnSyncEAlarmStateWTR OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SyncE Alarm State WRT."
::= { tnSyncEClkSourceEntry 10 }
tnSyncENominated OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SyncE Nominated."
::= { tnSyncEClkSourceEntry 11 }
--
-- SyncE port table
--
tnSyncEPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnSyncEPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of SyncEPort."
::= { tnSynce 3 }
tnSyncEPortEntry OBJECT-TYPE
SYNTAX TnSyncEPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing tnSynce."
INDEX { entPhysicalIndex, tnSyncEStatePortIndex }
::= { tnSyncEPortTable 1 }
TnSyncEPortEntry ::=
SEQUENCE {
tnSyncEStatePortIndex INTEGER,
tnSyncEStateTxSSM INTEGER,
tnSyncEStateRxSSM INTEGER,
tnSyncEStateSSMMode INTEGER,
tnSyncESSMEnabled INTEGER
}
tnSyncEStatePortIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SyncE Port index, 0-SYNCE_PORT_COUNT."
::= { tnSyncEPortEntry 1 }
tnSyncEStateTxSSM OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
prc(1),
ssua(2),
ssub(3),
dnu(4),
eec2(5),
eec1(6),
inv(7),
fail(8),
link(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SyncE Transmit SSM State."
::= { tnSyncEPortEntry 2 }
tnSyncEStateRxSSM OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
prc(1),
ssua(2),
ssub(3),
dnu(4),
eec2(5),
eec1(6),
inv(7),
fail(8),
link(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SyncE Receive SSM State."
::= { tnSyncEPortEntry 3 }
tnSyncEStateSSMMode OBJECT-TYPE
SYNTAX INTEGER
{
master(1),
slave(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SyncE SSM Mode."
::= { tnSyncEPortEntry 4 }
tnSyncESSMEnabled OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SyncE SSM Enabled."
::= { tnSyncEPortEntry 5 }
--
-- SyncE External I/O
--
tnSyncEExtTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnSyncEExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of SyncE External I/O"
::= { tnSynce 4 }
tnSyncEExtEntry OBJECT-TYPE
SYNTAX TnSyncEExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table,tnSyncEExtTable"
INDEX { entPhysicalIndex }
::= { tnSyncEExtTable 1 }
TnSyncEExtEntry ::= SEQUENCE
{
tnSyncEExtInState INTEGER,
tnSyncEExtOutState INTEGER,
tnSyncEExtInFreq INTEGER,
tnSyncEExtOutFreq INTEGER,
tnSyncEExtImpedance INTEGER,
tnSyncEActualInFreq INTEGER,
tnSyncEActualOutFreq INTEGER
}
tnSyncEExtInState OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "External I/O in direction state."
::= { tnSyncEExtEntry 1 }
tnSyncEExtOutState OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "External I/O out direction state."
::= { tnSyncEExtEntry 2 }
tnSyncEExtInFreq OBJECT-TYPE
SYNTAX INTEGER
{
f8kHz(1),
f64kHz(2),
f1544kHz(3),
f2048kHz(4),
f10000kHz(5),
f19440kHz(6),
f25Mhz(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "External I/O in direction frequency
8k-25Mhz table of values."
::= { tnSyncEExtEntry 3 }
tnSyncEExtOutFreq OBJECT-TYPE
SYNTAX INTEGER
{
f8kHz(1),
f64kHz(2),
f1544kHz(3),
f2048kHz(4),
f10000kHz(5),
f19440kHz(6),
f25Mhz(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "External I/O out direction frequency
8k-25Mhz table of values"
::= { tnSyncEExtEntry 4 }
tnSyncEExtImpedance OBJECT-TYPE
SYNTAX INTEGER
{
imp50(1),
imp75(2),
hi-Z(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "External I/O Impedance."
::= { tnSyncEExtEntry 5 }
tnSyncEActualInFreq OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The actual input frequency in Hz."
::= { tnSyncEExtEntry 6 }
tnSyncEActualOutFreq OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The actual output frequency in Hz. If output state is disabled set to 0"
::= { tnSyncEExtEntry 7 }
END