-- TN-SYNCE-MIB.smi:  Transition Networks Enterprise MIB for TN device SyncE feature
 | 
						|
--
 | 
						|
-- Copyright (c) 2013 by Transition Networks, Inc.
 | 
						|
-- All rights reserved.
 | 
						|
--
 | 
						|
-- ***********************************************************************************************
 | 
						|
--
 | 
						|
 | 
						|
TN-SYNCE-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
IMPORTS
 | 
						|
    TruthValue FROM SNMPv2-TC
 | 
						|
    MODULE-IDENTITY,
 | 
						|
    OBJECT-IDENTITY,
 | 
						|
    entPhysicalIndex FROM ENTITY-MIB
 | 
						|
    tnProducts FROM TRANSITION-SMI;
 | 
						|
 | 
						|
tnSynceMIB MODULE-IDENTITY
 | 
						|
    LAST-UPDATED "201305160000Z"
 | 
						|
    ORGANIZATION "Transition Networks, Inc."
 | 
						|
    CONTACT-INFO
 | 
						|
                "       Transition Networks
 | 
						|
                        Technical Support
 | 
						|
 | 
						|
                        10900 Red Circle Drive
 | 
						|
                        Minnetonka, MN 55343 USA
 | 
						|
                        Tel: +1-800-526-9267
 | 
						|
 | 
						|
                    E-mail: techsupport@transition.com"
 | 
						|
    DESCRIPTION
 | 
						|
        "The mib provides functionalities for managing SyncE."
 | 
						|
 | 
						|
    REVISION      "201305160000Z"
 | 
						|
    DESCRIPTION
 | 
						|
        "Initial Revision of this module"
 | 
						|
        ::= { tnProducts 122 }
 | 
						|
 | 
						|
tnSynce            OBJECT IDENTIFIER ::= { tnSynceMIB 1 }
 | 
						|
 | 
						|
tnSyncETable OBJECT-TYPE
 | 
						|
    SYNTAX     SEQUENCE OF TnSyncEEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
    "Table to manage SyncE for each device."
 | 
						|
    ::= { tnSynce 1 }
 | 
						|
 | 
						|
tnSyncEEntry OBJECT-TYPE
 | 
						|
    SYNTAX TnSyncEEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
    "An entry containing SyncE for each device."
 | 
						|
    INDEX   { entPhysicalIndex }
 | 
						|
    ::= { tnSyncETable 1 }
 | 
						|
 | 
						|
TnSyncEEntry ::=
 | 
						|
    SEQUENCE {
 | 
						|
        tnSyncEStateMode        INTEGER,
 | 
						|
        tnSyncEStateWTRTime     INTEGER,
 | 
						|
        tnSyncEStateSSMHoldOver INTEGER,
 | 
						|
        tnSyncEStateSSMFreeRun  INTEGER,
 | 
						|
        tnSyncEAlarmStateLOL    TruthValue,
 | 
						|
        tnSyncEAlarmStateDHOLD  TruthValue,
 | 
						|
        tnSyncESelState         INTEGER,
 | 
						|
        tnSyncEClkSrc           INTEGER
 | 
						|
    }
 | 
						|
 | 
						|
tnSyncEStateMode OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
                {
 | 
						|
                    manual(1),
 | 
						|
                    selected(2),
 | 
						|
                    nonrevertive(3),
 | 
						|
                    revertive(4),
 | 
						|
                    holdover(5),
 | 
						|
                    freerun(6)
 | 
						|
                }
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "Clock source selection mode
 | 
						|
     manual:       Selector is manually set to the chosen clock source
 | 
						|
     selected:     Selector is manually set to the pt. selected clock source (not possible in unlocked mode)
 | 
						|
     nonrevertive: Selector is automatically selecting the best clock source - non revertively
 | 
						|
     revertive:    Selector is automatically selecting the best clock source - revertively
 | 
						|
     holdover:     Selector is forced in holdover
 | 
						|
     freerun:      Selector is forced in free run"
 | 
						|
    ::= { tnSyncEEntry 1 }
 | 
						|
 | 
						|
tnSyncEStateWTRTime OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "WTR (Wait-to-Restore) time in minutes(0-12 min) '0' is disable"
 | 
						|
    ::= { tnSyncEEntry 2 }
 | 
						|
 | 
						|
tnSyncEStateSSMHoldOver  OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
                {
 | 
						|
                    none(0),
 | 
						|
                    prc(1),
 | 
						|
                    ssua(2),
 | 
						|
                    ssub(3),
 | 
						|
                    eec2(4),
 | 
						|
                    eec1(5),
 | 
						|
                    dnu(6),
 | 
						|
                    inv(7)
 | 
						|
                }
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "Synchronization Status Messaging Hold Over.
 | 
						|
    Hold Over is switching over to Local Reference Clock if primary and secondary nodes fail
 | 
						|
    prc = Primary Reference Clock
 | 
						|
    eec2 Ethernet Equipment Clock 1.544 kpbs
 | 
						|
    eec1 Ethernet Equipment Clock 2.048 kpbs"
 | 
						|
    ::= { tnSyncEEntry 3 }
 | 
						|
 | 
						|
tnSyncEStateSSMFreeRun OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
                {
 | 
						|
                     none(0),
 | 
						|
                     prc(1),
 | 
						|
                     ssua(2),
 | 
						|
                     ssub(3),
 | 
						|
                     eec2(4),
 | 
						|
                     eec1(5),
 | 
						|
                     dnu(6),
 | 
						|
                     inv(7)
 | 
						|
                }
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "Synchronization Status Messaging Free Run"
 | 
						|
    ::= { tnSyncEEntry 4 }
 | 
						|
 | 
						|
tnSyncEAlarmStateLOL OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
            "Alarm State Loss of Lock (LOL)"
 | 
						|
    ::= { tnSyncEEntry 5 }
 | 
						|
 | 
						|
tnSyncEAlarmStateDHOLD OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "Alarm State Digital Hold (DHOLD)"
 | 
						|
    ::= { tnSyncEEntry 6 }
 | 
						|
 | 
						|
tnSyncESelState OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
                {
 | 
						|
                    lockedto(1),
 | 
						|
                    holdover(2),
 | 
						|
                    freerun(3),
 | 
						|
                    prelock2(4),
 | 
						|
                    prelock(5),
 | 
						|
                    lossoflock(6)
 | 
						|
                }
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "Clock Selection State
 | 
						|
                 Note: prelock2, prelock and lossoflock
 | 
						|
                 are not available on all products"
 | 
						|
    ::= { tnSyncEEntry 7 }
 | 
						|
 | 
						|
tnSyncEClkSrc OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "Clock Source"
 | 
						|
    ::= { tnSyncEEntry 8 }
 | 
						|
 | 
						|
--
 | 
						|
-- SyncEClkSource
 | 
						|
--
 | 
						|
tnSyncEClkSourceTable  OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF TnSyncEClkSourceEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "Table of SyncE ClkSource"
 | 
						|
    ::= { tnSynce 2 }
 | 
						|
 | 
						|
tnSyncEClkSourceEntry  OBJECT-TYPE
 | 
						|
    SYNTAX      TnSyncEClkSourceEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "An entry in the table,tnSyncEClkSourceTable"
 | 
						|
    INDEX       { entPhysicalIndex, tnSyncEClkSourceIndex }
 | 
						|
    ::= { tnSyncEClkSourceTable 1 }
 | 
						|
 | 
						|
TnSyncEClkSourceEntry ::= SEQUENCE
 | 
						|
{
 | 
						|
    tnSyncEClkSourceIndex    INTEGER,
 | 
						|
    tnSyncEConfPort          INTEGER,
 | 
						|
    tnSyncEConfSSMOverwrite  INTEGER,
 | 
						|
    tnSyncEConfHoldOff       INTEGER,
 | 
						|
    tnSyncEConfANEG          INTEGER,
 | 
						|
    tnSyncEPriority          INTEGER,
 | 
						|
    tnSyncEClear             TruthValue,
 | 
						|
    tnSyncEAlarmStateLOCS    TruthValue,
 | 
						|
    tnSyncEAlarmStateSSM     TruthValue,
 | 
						|
    tnSyncEAlarmStateWTR     TruthValue,
 | 
						|
    tnSyncENominated         TruthValue
 | 
						|
}
 | 
						|
 | 
						|
tnSyncEClkSourceIndex  OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "Index of SyncE ClkSource table. 1-SYNCE_NOMINATED_MAX"
 | 
						|
    ::= { tnSyncEClkSourceEntry 1 }
 | 
						|
 | 
						|
tnSyncEConfPort  OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "SyncE Configuration Port. 0-MAX_PORT.
 | 
						|
                 a port value of 0 means not nominated"
 | 
						|
    ::= { tnSyncEClkSourceEntry 2 }
 | 
						|
 | 
						|
tnSyncEConfSSMOverwrite OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
                {
 | 
						|
                    none(0),
 | 
						|
                    prc(1),
 | 
						|
                    ssua(2),
 | 
						|
                    ssub(3),
 | 
						|
                    eec2(4),
 | 
						|
                    eec1(5),
 | 
						|
                    dnu(6)
 | 
						|
                }
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "Clock source SSM overwrite"
 | 
						|
    ::= { tnSyncEClkSourceEntry 3 }
 | 
						|
 | 
						|
tnSyncEConfHoldOff  OBJECT-TYPE
 | 
						|
    SYNTAX     INTEGER
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION "The hold off timer value in 100 ms.
 | 
						|
           Valid values are: 0 for disable. The range 3-18. The value 100 for test"
 | 
						|
    ::= { tnSyncEClkSourceEntry 4 }
 | 
						|
 | 
						|
tnSyncEConfANEG OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
                {
 | 
						|
                     none(0),
 | 
						|
                     slave(1),
 | 
						|
                     master(2),
 | 
						|
                     forced(3)
 | 
						|
                }
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "Auto Negotiate : 1000BaseT ANEG mode
 | 
						|
        slave:  Activate prefer slave negotiation
 | 
						|
        master: Activate prefer master negotiation
 | 
						|
        forced: Activate forced slave negotiation."
 | 
						|
    ::= { tnSyncEClkSourceEntry 5 }
 | 
						|
 | 
						|
tnSyncEPriority OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "Clock source priority setting. (SYNCE_PRIORITY_MAX = CLOCK_INPUT_MAX = 2 i.e. 0,1)"
 | 
						|
    ::= { tnSyncEClkSourceEntry 6 }
 | 
						|
 | 
						|
tnSyncEClear OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "SyncE Clear."
 | 
						|
    ::= { tnSyncEClkSourceEntry 7 }
 | 
						|
 | 
						|
tnSyncEAlarmStateLOCS OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "SyncE Alarm State LOCS."
 | 
						|
    ::= { tnSyncEClkSourceEntry 8 }
 | 
						|
 | 
						|
tnSyncEAlarmStateSSM OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION " SyncE Alarm State SSM."
 | 
						|
    ::= { tnSyncEClkSourceEntry 9 }
 | 
						|
 | 
						|
tnSyncEAlarmStateWTR OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "SyncE Alarm State WRT."
 | 
						|
    ::= { tnSyncEClkSourceEntry 10 }
 | 
						|
 | 
						|
tnSyncENominated OBJECT-TYPE
 | 
						|
    SYNTAX      TruthValue
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "SyncE Nominated."
 | 
						|
    ::= { tnSyncEClkSourceEntry 11 }
 | 
						|
 | 
						|
--
 | 
						|
-- SyncE port table
 | 
						|
--
 | 
						|
tnSyncEPortTable  OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF TnSyncEPortEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "Table of SyncEPort."
 | 
						|
    ::= { tnSynce 3 }
 | 
						|
 | 
						|
 | 
						|
tnSyncEPortEntry OBJECT-TYPE
 | 
						|
    SYNTAX TnSyncEPortEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION
 | 
						|
    "An entry containing tnSynce."
 | 
						|
    INDEX   { entPhysicalIndex, tnSyncEStatePortIndex }
 | 
						|
    ::= { tnSyncEPortTable 1 }
 | 
						|
 | 
						|
TnSyncEPortEntry ::=
 | 
						|
    SEQUENCE {
 | 
						|
                tnSyncEStatePortIndex INTEGER,
 | 
						|
                tnSyncEStateTxSSM INTEGER,
 | 
						|
                tnSyncEStateRxSSM INTEGER,
 | 
						|
                tnSyncEStateSSMMode INTEGER,
 | 
						|
                tnSyncESSMEnabled  INTEGER
 | 
						|
             }
 | 
						|
 | 
						|
tnSyncEStatePortIndex OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "SyncE Port index, 0-SYNCE_PORT_COUNT."
 | 
						|
    ::= { tnSyncEPortEntry 1 }
 | 
						|
 | 
						|
tnSyncEStateTxSSM OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
                {
 | 
						|
                    none(0),
 | 
						|
                    prc(1),
 | 
						|
                    ssua(2),
 | 
						|
                    ssub(3),
 | 
						|
                    dnu(4),
 | 
						|
                    eec2(5),
 | 
						|
                    eec1(6),
 | 
						|
                    inv(7),
 | 
						|
                    fail(8),
 | 
						|
                    link(9)
 | 
						|
                }
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "SyncE Transmit SSM State."
 | 
						|
    ::= { tnSyncEPortEntry 2 }
 | 
						|
 | 
						|
tnSyncEStateRxSSM OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
                {
 | 
						|
                    none(0),
 | 
						|
                    prc(1),
 | 
						|
                    ssua(2),
 | 
						|
                    ssub(3),
 | 
						|
                    dnu(4),
 | 
						|
                    eec2(5),
 | 
						|
                    eec1(6),
 | 
						|
                    inv(7),
 | 
						|
                    fail(8),
 | 
						|
                    link(9)
 | 
						|
                }
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "SyncE Receive SSM State."
 | 
						|
    ::= { tnSyncEPortEntry 3 }
 | 
						|
 | 
						|
tnSyncEStateSSMMode OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
                {
 | 
						|
                    master(1),
 | 
						|
                    slave(2)
 | 
						|
                }
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "SyncE SSM Mode."
 | 
						|
    ::= { tnSyncEPortEntry 4 }
 | 
						|
 | 
						|
tnSyncESSMEnabled OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
                {
 | 
						|
                    enable(1),
 | 
						|
                    disable(2)
 | 
						|
                }
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "SyncE SSM Enabled."
 | 
						|
    ::= { tnSyncEPortEntry 5 }
 | 
						|
 | 
						|
--
 | 
						|
-- SyncE External I/O
 | 
						|
--
 | 
						|
tnSyncEExtTable  OBJECT-TYPE
 | 
						|
    SYNTAX      SEQUENCE OF TnSyncEExtEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "Table of SyncE External I/O"
 | 
						|
    ::= { tnSynce 4 }
 | 
						|
 | 
						|
tnSyncEExtEntry  OBJECT-TYPE
 | 
						|
    SYNTAX      TnSyncEExtEntry
 | 
						|
    MAX-ACCESS  not-accessible
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "An entry in the table,tnSyncEExtTable"
 | 
						|
    INDEX       { entPhysicalIndex }
 | 
						|
    ::= { tnSyncEExtTable 1 }
 | 
						|
 | 
						|
TnSyncEExtEntry ::= SEQUENCE
 | 
						|
{
 | 
						|
    tnSyncEExtInState        INTEGER,
 | 
						|
    tnSyncEExtOutState       INTEGER,
 | 
						|
    tnSyncEExtInFreq         INTEGER,
 | 
						|
    tnSyncEExtOutFreq        INTEGER,
 | 
						|
    tnSyncEExtImpedance      INTEGER,
 | 
						|
    tnSyncEActualInFreq      INTEGER,
 | 
						|
    tnSyncEActualOutFreq     INTEGER
 | 
						|
}
 | 
						|
 | 
						|
tnSyncEExtInState  OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
                {
 | 
						|
                    enable(1),
 | 
						|
                    disable(2)
 | 
						|
                }
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "External I/O in direction state."
 | 
						|
    ::= { tnSyncEExtEntry 1 }
 | 
						|
 | 
						|
tnSyncEExtOutState  OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
                {
 | 
						|
                    enable(1),
 | 
						|
                    disable(2)
 | 
						|
                }
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "External I/O out direction state."
 | 
						|
    ::= { tnSyncEExtEntry 2 }
 | 
						|
 | 
						|
tnSyncEExtInFreq  OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
                {
 | 
						|
                    f8kHz(1),
 | 
						|
                    f64kHz(2),
 | 
						|
                    f1544kHz(3),
 | 
						|
                    f2048kHz(4),
 | 
						|
                    f10000kHz(5),
 | 
						|
                    f19440kHz(6),
 | 
						|
                    f25Mhz(7)
 | 
						|
                }
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "External I/O in direction frequency
 | 
						|
                 8k-25Mhz table of values."
 | 
						|
    ::= { tnSyncEExtEntry 3 }
 | 
						|
 | 
						|
tnSyncEExtOutFreq  OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
                {
 | 
						|
                    f8kHz(1),
 | 
						|
                    f64kHz(2),
 | 
						|
                    f1544kHz(3),
 | 
						|
                    f2048kHz(4),
 | 
						|
                    f10000kHz(5),
 | 
						|
                    f19440kHz(6),
 | 
						|
                    f25Mhz(7)
 | 
						|
                }
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "External I/O out direction frequency
 | 
						|
                 8k-25Mhz table of values"
 | 
						|
    ::= { tnSyncEExtEntry 4 }
 | 
						|
 | 
						|
tnSyncEExtImpedance  OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
                {
 | 
						|
                    imp50(1),
 | 
						|
                    imp75(2),
 | 
						|
                    hi-Z(3)
 | 
						|
                }
 | 
						|
    MAX-ACCESS  read-write
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "External I/O Impedance."
 | 
						|
    ::= { tnSyncEExtEntry 5 }
 | 
						|
 | 
						|
tnSyncEActualInFreq  OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "The actual input frequency in Hz."
 | 
						|
    ::= { tnSyncEExtEntry 6 }
 | 
						|
 | 
						|
tnSyncEActualOutFreq  OBJECT-TYPE
 | 
						|
    SYNTAX      INTEGER
 | 
						|
    MAX-ACCESS  read-only
 | 
						|
    STATUS      current
 | 
						|
    DESCRIPTION "The actual output frequency in Hz. If output state is disabled set to 0"
 | 
						|
    ::= { tnSyncEExtEntry 7 }
 | 
						|
END
 |